HomeMy WebLinkAboutPermit M17-0004 - BILLY BAROO'S - DUCT HEATERBILLY BAROO'S 13500 INTERiJRBAN AVE S M17-0004 Parcel No: Address: r City of Tukwila Department of Community Development ��v� 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 � Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0003000049 Permit Number: 13500 INTERURBAN AVE S Project Name: BILLY BAR00'S Issue Date: Permit Expires On: M 17-0004 1/23/2017 7/22/2017 Owner: Name: TUKWILA CITY OF Address: 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 Contact Person: Name: TERESE ANDERSON Address: 1221 SECOND AVE N , KENT, WA, 98032 Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AVE N , KENT, WA, 98032- 2945 License No: HERMACLOO5BJ Lender: Name: Address: 1 Phone: (253) 796-5825 Phone: (206) 575-9700 Expiration Date: 8/25/2018 DESCRIPTION OF WORK: REPLACE ONE INLINE DUCT HEATER FOR MUA FOR THE KITCHEN Valuation of Work: $8,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $313.23 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: ki(Ld T Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: ^ - Date: //2,3b7 Print Name:712,L This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Nitt-7- 066/ Date Application Accepted: Date Application Expires: k -si (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 13500 Interurban Avenue South Billy Baroos King Co Assessor's Tax No.: 0003000049 Suite Number: New Tenant: PROPERTY OWNER Name: Terese Anderson Name: City Of Tukwila City: Kent State: WA Zip: 98032 Address: 6200 Southcenter Blvd Email: tanderson@hermanson.com City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Terese Anderson Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (206) 575-9700 Fax: Email: tanderson@hermanson.com Floor: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (206) 575-9700 Fax: Contr Reg No.: hermae1005bj Exp Date: 08/2017 Tukwila Business License No.: bus0994464 Valuation of project (contractor's bid price): $ 8,000 Describe the scope of work in detail: replace one inline duct heater for MUA for the kitchen Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Other: H: Applications Forms -Applications On Line 201 1 Applications Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 1 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type. Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 Signature: AGENT: Print Name: Terese Anderson Mailing Address: 1221 2nd Ave N H: Applications•Fortns-Applications On Line2011 Applications' Mechanical Permit Application Revised 0-9-11.docx Revised: August 2011 bh Date: I j l 1(17- Day ,1 TDay Telephone: (206) 200-7804 Kent WA 98032 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY PAID $384.94 EL17-0036 Address: 13500 INTERURBAN AVE S Apn: 0003000049 $71.71 Credit Card Fee $2.09 Credit Card Fee 1 R000.369.908.00.00 I 0.00 I $2.09 ELECTRICAL $66.30 PERMIT FEE MULTI-FAM/COMM 1 R000.322.101.00.00 ( 0.00 I $66.30 TECHNOLOGY FEE $3.32 TECHNOLOGY FEE 1 R000.322.900.04.00 0.00 I $3.32 M17-0004 Address: 13500 INTERURBAN AVE S Apn: 0003000049 $313.23 Credit Card Fee $9.12 Credit Card Fee I R000.369.908.00.00 0.00 $9.12 MECHANICAL $292.41 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $200.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $58.48 TECHNOLOGY FEE $11.70 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10387 R000.322.900.04.00 0.00 $11.70 $384.94 Date Paid: Wednesday, January 11, 2017 Paid By: TERESE ANDERSON Pay Method: CREDIT CARD 637990 Printed: Wednesday, January 11, 2017 1:44 PM 1 of 1 CRSYSTEMS oa INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 /1417- 000 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: ',may .74--1.00 s Type of Inspection: tV6-- %4/ ��c/-L FAA - Address: /j' -c /4/7WRIRMAI MI Date Called: Special Instructions: Date Wanted: —2—/7 �rt p.m. Requester: PI iKf- LeP0Ar Phone No: 20,-- (e78"—(4/2 ? kApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspec -s. „1t 5 Date: ,a -17 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0004 DATE: 01/11/17 PROJECT NAME: BILLY BAROO'S SITE ADDRESS: 13500 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: kJ awU 11 1`► Building Divisio Public Works ❑ fa Fire Preventio Structural Planning Division ❑ Permit Coordinator C PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/12/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/09/17 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: 'Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 HERMANSON COMPANY LLP shington State Department of abor & Industries • Home Espanol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 3 Withy. A -Z Index Help Aly L&1 Workplace Rights Trades & Licensing HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No. 602 004 844 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County Business type Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. HERMACLOO5BJ Effective — expiration 01/11/2000— 08/25/2018 Bond WESTERN SURETY CO Bond account no. 929381801 $12,000.00 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 1/19/2017 HVAC GENERAL NOTES 1. VERIFY SITE CONDITIONS. 2. THERMOSTAT LOCATIONS: VERIFY ALL WALL MOUNTED CONTROL LOCATIONS WITH ARCHITECT/GC. 3. CODES: COMPLY WITH ALL LOCAL & STATE GOVERNING CODES. 4. COORDINATE DUCTWORK AND GRILLE LOCATIONS WITH LIGHTING AND OTHER RELATED TRADES WITH ARCHITECT APPROVAL VERIFY CLEARANCES & CEILING ELEVATIONS BEFORE INSTALLATION. 5. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. 6. SEISMIC BRACING: PROVIDE TO MEET LOCAL CODE REQUIREMENTS. REFER TO THE ASHRAE STANDARDS "PRACTICAL GUIDE TO SEISMIC RESTRAINT", 2012. 7. EXHAUST FAN TERMINATION: SHALL NOT BE LESS THAN 3 FEET FROM A PROPERTY UNE OR OPENINGS INTO A BUILDING, E.G., OPERABLE WINDOWS AND DOORS, OR DISTANCE AS REQUIRED PER LOCAL CODE. 8. TEST, ADJUST, & BALANCE: PROVIDE PROPER SYSTEM TESTING, ADJUSTING, AND BALANCING, INCLUDING WRITTEN REPORTS TO BE PROVIDED TO OWNER. BALANCE TO WITHIN 10% OF DESIGN. 9. OPERATION & MAINTENANCE BOOKLET: PROVIDE 0 & M MANUAL TO OWNER. INCLUDE CUT SHEETS ON MAIN EQUIPMENT AND CONTROLS, MAINTENANCE INSTRUCTIONS, AND MARKED UP AS -BUILT DRAWING. 6. 10. COMMISSIONING: PRIOR TO PASSING THE FINAL INSPECTION OR OBTAINING A CERTIFICATE OF OCCUPANCY, PROVIDE THE EVIDENCE OF SYSTEM COMMISSIONING AND COMPLETION IN ACCORDANCE WITH THE PROVISIONS OF SECTION C408 OF THE 2015 WSEC 11. WALK-THRU INSTRUCTION: PROVIDE ON SITE WALK-THRU FOR CUSTOMER TO DEMONSTRATE 7, OPERATION OF SYSTEM AND ANSWER QUESTIONS. 12. ROOF TOP UNITS ON CURB: SEAL HOLES AND CRACKS BETWEEN DUCT AND ROOF DECK INSIDE FACTORY ROOF CURB FOR NOISE CONTROL 13. GAS PIPE: SCHEDULE 40, BLACK STEEL PAINT PIPE EXPOSED TO WEATHER. 14. SIZES: ALL PIPE SIZES SHOWN ARE MINIMUM. 8. 15. PIPE HANGERS: SWIVEL LOOP STYLE, MICHIGAN NO.100 OR CLEVIS STYLE, NO.400 OR EQUAL BRAND, WITH ALTHERED STEEL ROD SIZED PER INDUSTRY STANDARDS. 9 16. ELECTRICAL: ALL EQUIPMENT TO HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN ' SIGHT FROM EQUIPMENT SERVED. PROVIDE A 120 VOLT RECEPTACLE LOCATED WITHIN 25 FEET OF EQUIPMENT FOR SERVICE & MAINTENANCE PURPOSES (2015 IMC SECTION 301.10). UNE VOLTAGE WORK BY OTHERS. 10. 17. SUSPENDED MECHANICAL EQUIPMENT AND APPLIANCES SHALL HAVE RIGID VERTICAL HANGERS AND BE BRACED IN BOTH HORIZONTAL DIRECTIONS. DUCT NOTES 1. 2. 3. 4. 5. DUCT CONSTRUCTION AND INSTALLATION PER LATEST SMACNA STANDARDS AND THE 2015 IMC AS REQUIRED BY THE LOCAL CODE. PROVIDE METAL DUCT, EXCEPT AS NOTED. BALANCING DAMPERS: PROVIDE ON ALL SUPPLY RUN OUT DUCTS UP STREAM OF DIFFUSERS. DUCT INSULATION: DUCTS, SHAFTS AND PLENUMS SHALT. BE INSULATED TO MINIMUM OF R-8 AND IN ACCORDANCE WITH THE SECTION C403.2.8 OF 2015 WSEC. DUCT SEALING -GENERAL: 0 TO 2" STATIC PRESSURE - SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS ON ALL DUCTS. ABOVE 2" -SEAL SEAMS, JOINTS AND WALL PENETRATIONS. INSIDE BUILD: DURODYNE "DDS -181" GRAY OR APPROVED EQUAL PER UL 181 A -M, 181B -M LISTED. OUTSIDE: POLYURETHANE, MAMECO VULKEM 116. OR APPROVED EQUAL TURN VANES: PROVIDE SINGLE THICKNESS TURN VANES (SEE DETAIL) IN ALL MAJOR SQUARE DUCT ELBOWS, TEES, OR TURNS WITH INSIDE RADIUS LESS THAN 3/4 DUCT WIDTH. SQUARE BRANCH DUCT TAPS SHALL BE 45 DEGREE TYPE PER SMACNA STANDARD. FLEX DUCT (INSULATED): FOR GRILLE RUN OUTS UP TO 6 FT. LONG, EXCEPT AS NOTED. PROVIDE ADJUSTABLE METAL ELBOWS ON ALL TURNS, UNLESS A SMOOTH FULL RADIUS TURN IS MADE. SECURE CORE WITH APPROVED NYLON OR METAL WORM DRIVE CLAMPS. NO DUCT TAPE JOINTS & SCREWS ALLOWED. SOUND LINER: PROVIDE SOUND LINED METAL SUPPLY & RETURN DUCTS AS SHOWN ON PLANS. MANVILLE PERMACOTE UNACOUSTIC FLEXIBLE FIBERGLASS LINER, WITH ACRYLIC SURFACE TREATMENT OR EQUAL FABRICATE AND INSTALL PER DUCT LINER STANDARD OF NORTH AMERICAN INSULATION MANUFACTURER'S ASSOC. OUTSIDE AIR DUCT IS NOT INSULATED THROUGH UNCONDITIONED AREA. FLEX CONNECTORS: PROVIDE ON ALL DUCT HOOK-UPS TO ISOLATE AIR HANDLING EQUIPMENT. (NEOPRENE COATED FIBERGLASS FABRIC TYPE) DUCT SIZE CHANGES: ROUND GALVANIZED DUCTS MAY BE SUBSTITUTED FOR RECTANGULAR DUCTS THAT ARE NOT UNED. PROVIDE CIRCULAR EQUIVALENT OF RECTANGULAR DUCT. OTHER EQUIVALENT RECTANGULAR DUCT SIZES MAY BE SUBSTITUTED TO BETTER FIT SPACE. TEMPORARY DUCT CLOSURE: SEAL OFF DUCTWORK DURING CONSTRUCTION TO KEEP OUT CONSTRUCTION DUST, ESPECIALLY FLOOR BOOTS AND LOW WALL OPENINGS. ROOFTOP PACKAGE UNIT SCHEDULE TAG MAKE MODEL NOM TONS COOLING [MBH] HEATING [MBH] SEER AT AHRI SUPPLY FAN SP [IN. WC] TOTAL CFM MCA/MOP [AMPS] VOLTAGE [V -PH] WT [LBS] MIN OSA CFM CONDITION NOTE TOTAL SENS. INPUT OUTPUT BHP RPM DRIVE TYPE GP -8A LENNOX KGBO48S4D 4 49.7 47.5 65 52 14.0 0.5 - D0 0.56 1600 31/50 230-1 686 250 NEW 1,2,3,4,5 GP -5 TRANE REZNOR V3 TCORE2 5 60.0 - - - - - - - 1 2000 230-3 - 160 EXISTING 3 GP -6 TRANE YSC060A3 1 RO 5 60:0 2000 230-3 - 453 EXON 3 1. INCLUDES THE WEIGHT OF ALL ACCESSORIES 2. 7 DAY PROGRAMOBLE THERMOSTAT HONEYWELL T-8800 3. W/ ECONOMIZER (100% OSA) 4. STRUCTURAL CALCUt.AT1N IS PROVIDED SEPARATELY 5. GP -8A REPLACES EXISTING UNIT GP -8 WITH 75.0 MBH HEATIGN INPUT EXHAUST FAN SCHEDULE UNIT NO. SERVICE AND LOCATION MANUFACTURER & MODEL NO. CFM ESP (In H20) VOLT/ PHASE AMPS LBS NOTES EF -1 RESTROOM PANASONIC FV-VQC5 110 0.1 120/1 0.22 9.91 1,2 EF -2 RESTROOM PANASONIC FV-VQC5 110 0.1 120/1 0.22 9.91 1,2 EF -3 RESTR PANASONIC FV-VQC5 110 0.1 120/1 0.22 9.91 1,2 EF -4 JANITOR PANASONIC FV-VQC5 110 0.1 120/1 0.22 9.91 1,2 NOTES: 1. DISCONNECT BY ELECTRICAL CONTRACTOR 2. REPLACE EXISTING EXHAUST FANS. UNIT HEATER SCHEDULE UNIT NO. SERVICE & LOCATION MANUFACTURER & MODEL HEATING, MB AFUE BLOWER ELECTRICAL WT/ NOTE INPUT OUTPUT CFM RPM HP VOLT/PH APIALBS UH -1 WAREHOUSE REZNOR AEH3183N053 75.0 60.0 - - - - - - - 1 UH -2 WAREHOUSE DAYTON 3XXXXX 75.0 60.75 - - - - 115/1 3 - 1 UH -3 WAREHOUSE REZNOR V3 TCORE2 75.0 30.0- - - - - - - - 1 NOTES: 1. EXISTING UNIT HEATER. DRAWING INDEX M-1 LEGEND & ABBREVIATIONS, VICINITY MAP, NOTES, EQUIPMENT SCHEDULE M-2 EXISTING AND NEW HVAC REFLECTIVE CEILING PLAN M-3 HVAC ROOF PLAN LEGAL DESCRIPTION: POR W 1/2 OF SEC 25 & E 1/2 OF SEC 26 AS FOLG BEG AT E 1/4 COR SEC 26 TH N 88-06-42 W 105.84 FT TO TPOB TH N 01-47-28 E 2.45 FT TAP OF CURVE TH ALG A CURVE TO RGT RAD 410.28 FT THRU C/A OF 46-46-10 ARC DIST 334.90 FT TH N 48-33-38 E 188.36 FT TH ALG A CURVE TO RGT RAD 410.28 FT THRU C/A OF 72-16-35 ARC DIST 517.55 FT TO AN NXN WITH A LN BEARING S 56-38-20 E S 56-38-20 E ALG SD LN 69.93 FT TH S 48-44-23 E 71.30 FT TH S 45-09-27 E 9.91 FT TO WLY MGN OF JAMES CHRISTENSEN RD NO 1479 TH S 37-54-41 W 468.23 FT TH S 32-39-25 W 132.67 FT TH N 88-12-32 W 524.50 FT TH N 01-47-28 E 93.11 FT TO TPOB LESS UP RR OPER R/W TAX PARCEL NUMBER: 252304-9008 ANDOVER BLDG 13 VICINITY MAP NTS AREA OF WORK, 641 INDUSTRY DR 11111111111,.... ANDOVER BLDG 13 NTS ►1 z LEGEND & ABBREVIATIONS ABBREV, DESCRIPTION SUPPLY DUCT RETURN/EXHAUST DUCT SOUNDUNED DUCT MANUAL VOLUME DAMPER FLEX CONNECTOR TURNING VANES END CAP SUPPLY DIFFUSER, CEILING MAKEUP GRILLE RETURN GRILLE, CL9UNG EXHAUST GRILLE, CEILING TRANSFER GRILLE, CEILING SIDEWALL SUPPLY/MAKEUP SIDEWALL RETURN/EXHAUST EQUIPMENT TAG ABOVE FINISHED FLOOR BACKDRAFT DAMPER BIRDSCREEN DOWN EXHAUST AIR OUTSIDE AIR RETURN AIR SUPPLY AIR SL VD FC TV EC SD MG RG EG TG AFF BD, BDD BS DN EA OA, OSA RA SA (N) NEW (E)/EXIST EXISTING (R) RELOCATED BWG BOTTOM WALL GRILLE MG TOP WALL GRILLE TYP TYPICAL VI) VOLUME DAMPER DEMO C=) REVISIONS AIR TERMINAL LEGEND GRILLE, REGISTER, XX 8x8 DIFFUSER IN LEGEND -r'' 140 XX 8'0 SYMBOL • ABBREV. DESCRIPTION FIRE DAMPERED DUCT PENETRATION OF A HORIZONTAL SEPARATION V FIRE DAMPERED DUCT PENETRATION OF A VERTICAL SEPARATION m O Q CD 0 TIMER 0-4 HR ADJUSTABLE THERMOSTAT/HVAC UNIT # SENSOR/HVAC UNIT # SENSOR (CEILING MOUNT) EXHAUST FAN PIPE/DUCT UP PIPE/DUCT DOWN PIPE TEE DOWN PIPE TEE UP EXIST DUCTWORK, EQUIP NEW DUCTWORK, EQUIP CEILING RADIATION DAMPER ADJ ADJACENT BSC BIOLOGICAL SAFETY CABINET CFH CHEMICAL FUME HOOD CFM CUBIC FEET PER MINUTE DB DUCT BOARD L,S LIQUID, SUCTION N NECK NIC NOT IN CONTRACT OAI OUTSIDE AIR INTAKE RD ROUND DIFFUSER SHC SENSIBLE HEATING CAPACITY SR SUPPLY REGISTER TC TOTAL COOLING VEL VELOCITY WH WATER HEATER SC SOUND CAN NECK SIZE (INCHES) SQUARE OR RECTANGULAR AIR QUANTITY (CFM) NECK SIZE (INCHES) 140 ROUND Air Quantity (CFM) ARROWS INDICATE AIR PATTERN FOR CEILING DIFFUSERS NO ARROWS INDICATE FOUR WAY PATTERN Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 1916 220th Street SE Suite M101 Bothell, WA 98011 ph: (206) 682-6393 fax: (206) 340-2270 Contractor's License No.: PACIFAC230P8 0 I-- 0 W ct r,:iveoNs 0 No changes -I,^►; I rade to the of work withc c prior approval Tukwila Building Divisio 1. eL NOTE: Revisions will require a new plan mittai and may include additional plan review/cos. 1 W U W O z w FILE COPY Permit No. M 1/0001 ANDOVER BLDG 13 ri co to a) >10. ott .11 ca 1� DATE 12/20/16 DESCRPTION PERMIT ISSUE A Plan reviaw } ia subject to errors and onnissi6 FIRE SPRINKLER HEADS TO BE FAST REACTION TYPE BY OTHERSAppraval of core,, u ion documents does not autio 'z DESCRIPTION OF WORK: DEMO SOME DUCTWORK AND CAP RUNS, SEE SHEET M-2. the violation of any adopted code or ordinance. P'; # of approved Field Copy and conditions is acknotiv'c* By: Date: D//y / q - City of Tukwila BUILDING DIVISION 2. PROVIDE NEW RUNS, DIFFUSERS, RETURN GRILLES, AND (2) T -STATS, SEE SHEET M-2. 3. REPLACE EXISTING UNIT GP -8, SEE SHEET M-1, M-3. 4. REPLACE (4) EXISTING EXHAUST FANS, SEE SHEET M-1, M-2. 5. PROVIDE AIR BALANCE FOR SUPPLY DIFFUSERS AN�� " M-1, M-2. r->.LI�i IT IJ r--U -0 FOR: 0 Mechanical d-!nca !active,' umbing Gas Piping City of Tukwila BLAMING DIVISION RECEIVED CITY OF TUKVVILA JAN 0 s 2017 F1LEPATH: !Projects\ANDOVER\Andover Bldg 13 Western Food Service A THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL, INC. ANY REPRODUCTION, DUPLICATION, ADDITIONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. PROJECT MANAGER AH DESIGNED BY KC/AH DRAIN BY AH CHECKED BY KC SCALE AS NOTED PRO.ECT NO. T161204 DRAWING TITLES LEGEND & ABBREVIATIONS EQUIPMENT SCHEDULE VICINITY MAP, NOTES REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 6 2017 SHEET NUMBER City of Tukwila BUILDING DIVISION 1 of 3 COPYRIGHT - 2001 PACIFIC AIR CONTROL, INC. SCOPE OF WOK SCOPE OF WORK It // // // — — = = = = = = = Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 1916 220th Street SE Suite M101 I Bothell, WA 98011 ph: (206) 682-6393 fax (206) 340-2270 Contractor's License No.: PACIFAC230P8 I i (N)951 14X8 320 CFM TYP.(5) (N)951 12X6 150 CFM TYP.(2) (N)14"0 )14'� .(N)8;t8 150CFM 0 0 0 NO. DATE 12/20/16 DESCRIPTION PERMIT ISSUE (N)EF-1 (N)EF-2 (N)EF-4 _ 0 • p Z eY,M *WO aNg,5j**006 ASSW „1/0000,4 401.w..0.0* .(N)8x6 100CFM 1 OM 8 THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL INC. ANY REPRODUCTION, DUPUCATION, ADDMONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL INC. PROJECT MANAGER AH DESIGNED BY KC/AH DRAIN BY AH CHECKED BY KC SCALE AS NOTED PROJECT NO. T161204 '7x 2 1 ? _CFM ? CFM F. 12x12 -400-CFM TYP.(2) (N)RG-1 DRAK1NG TITLES EXISTING AND NEW HVAC REFLECTIVE 8 x 8 8)(8 r ,n r.);se) 250CRI TYP.(2) CEIUNG PLAN ?CFM ?CFM ///, HI:VIEWED FOR CODE COMPLIANCE APPROVED RECEIVED CITY OF TUKWILA JAN -0-6-2017 SHEET :UMBER JAN 0 3 2017 PERMIT CENTER EXISTING HVAC REFLECTIVE CEILING PLAN SCALE 3/16"=1' NEW HVAC REFLECTIVE CEILING PLAN M I SCALE 3/16"=1' City of Tukwila BUILDING DIVISION M-2 of 3 FlUEPATH: !Projects \ANDOVERNAndover Bldg 13 Western Food Service COPYRIGHT _ 2001 PACIFIC AIR CONTROL, INC. Air Conditioning r SCO p WOKControls E OF ���"``��'�{"�°�� Heating Sa! Service Installation _._...r -___. Cd} _..... "QUALITY ASSURED" v_ pacific air control, inc. 1916 220th Street SE Suite M101 C> r C7 , L., �'�'� 7 ______________ _._.. c_:::, Bothell, WA 98011 ph: (206) 682-6393 fax: (206) 340-2270 H 3 Contractor's License No.: PACIFAC230P8 II 1l I 1 : U1-1— P N 1 1 r -I X /1 L J ( _ J I W U Liu co U1 (v.) > co ( i r I 1 `s iGP-1 it 0 CI ` GP -7 r-----------, - >" 64t 1 1 I r----1 \ X 0 CO it oion 0 it IG , 1 <f 3 L --J LJ 0 === H it !!! _... r- i Z 't"'" 0 —3 IL L iTi _, rJ J CI) I I � ' _ ®�—J 1 3/4 o 1" \ » , ,....,O !f \,-------ti NII TO B- GP -6 L.,..., I . EPACED \ 1 J (f] -' O GP -8A I r-- —, 1i GP -2 , >< \o / a.— / X( ><\No. GP -3 I \. DATE DESCRIPTION ''',,,,,., 12/20/16 PERMIT ISSUE /% i GP -4® O _10' IC A ANY t LAA.✓ V T A A 1 , A THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR �P-5 CONTROL INC. ANY REPRODUCTION,ON, ADDITIONS AND/OR MODIFICATIONS REQUIRE THE L� WRI tN APPROVALF PACIFIC AIRNCON1T20�TINC. „...._ E ESTROOM / PROJECT /IMAM? AH DES'G4'ED BY KC/AH EXHAJST VENTS X DRAIN BY AH CHECKED BY KC L___—J i 7 SCALE AS NOTED PROJECT N0. T161204 — DRAI'ss'NO TITLES ROOF PLAN _ 0 0 - 0 ❑q G ❑ = 0 0 q c] 0 0 n 0 0 4,-., REVIEWED FOR CODE COMPLIANCE t , } APPROVED JAN 0 6 2017 RECEIVED - 1ITV OF TUKWILA SHEET NOM. City of Tukwila BUILDING DIVISION JAN 0S. 2017 aERiV1IT CENTER ROOF PLAN{` SCALE 3/16$=1'M.- (II i 3 of 3 FlLEPATH: !Projects\ANDOVER\Andover Bldg 13 Western Food Service COPYRIGHT 2001 PAGFlC AIR CONTROL, INC.