Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M17-0015 - ZCOLO - CHILLED WATER WORK
ZCOLO 3311 S 120 PL M17-0015 Parcel No: Address: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 1023049078 Permit Number: M17-0015 3311 S 120TH PL 120TH Project Name: ZCOLO Issue Date: 2/8/2017 Permit Expires On: 8/7/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SABEY CORPORATION 12201 TUKWILA INTL BLVD 4TH FL , SEATTLE, WA, 98168 JOYCE COPLEY Phone: (206) 407-2614 7717 DETROIT AVE SW , SEATTLE, WA, 98106 MACDONALD/MILLER FAC SOL INC Phone: (206) 768-4180 PO BOX 47983 , SEATTLE, WA, 98146- 7983 MACDOFS980RU Expiration Date: 1/4/2019 DESCRIPTION OF WORK: PROVIDE/INSTALL NEW CHILLED WATER PIPING AND INSTALL (2) NEW OWNER PROVIDED 300TOTRANE CHILLERS WITH SECONDARY ECONOMIZER COILS. REMOVE (2) OLD 200 TON YORK CHILLERS AFTER NEW CHILLERS ARE STARTED UP AND COMMISIONED. INSTALL (2) NEW OWNER PROVIDED CHILLED WATER COMPUTER ROOM AC UNITS. UPSIZE TWO EXISTING CHILLED WATER PUMPS AND INSTALL A 3RD NEW PUMP Valuation of Work: $254,157.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $3,167.42 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125,TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 r -P1 Permit Center Authorized Signature: Date: AIK€2-'—a-- I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this developmer per .t and agree to the conditions aached to t is permit. Signature: Print Name: Date -7F/'/ / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 4: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ***MECHANICAL PERMIT CONDITIONS*** 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 12: Manufacturers installation instructions shall be available on the job site at the time of inspection. 13: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 24: Ensure that fire department access to the exterior fire sprinkler system valves and fire department connection is provided and is properly identified with permanent weather-resistant readily visible signage. 14: H.V.A.C. units rated at greater than 2,000 cfm require auto-shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air-moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air-duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH-IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY bF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi IaWA.gov Mechanical Permit No. Project No. Date Application Accepted: I —)—(o —17 (For office use only) Date Application Expires: MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 1023049078 Site Address: 3311 South 120th Place, Tukwila 98168 Suite Number: 120 Floor: GROUND Tenant Name: zColo New Tenant: ❑ Yes ®..No PROPERTY OWNER Name: Joyce Copley Name: SABEY CORPORATION City: Seattle state: WA Zip: 98106 Address: 3311 South 120th Place Email: Joyce.Copley@MACMILLER.COM City: TUKWILA State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Joyce Copley Address: 7717 Detroit Ave SW City: Seattle state: WA Zip: 98106 Phone: (206) 407-2614 Fax: (206) 905-3749 Email: Joyce.Copley@MACMILLER.COM MECHANICAL CONTRACTOR INFORMATION Company Name: MacDonald Miller Address: 7717 Detroit Ave SW City: Seattle State: WA Zip: 98106 Phone: (206) 905-3748 Fax: (206) 905-3749 Contr Reg No.: MACDOFS980RU Exp Date: 01/04/2019 Tukwila Business License No.: BUS -0994318 Valuation of project (contractor's bid price): $ 254,157 Describe the scope of work in detail: Provide/install new chilled water piping and install (2) new OWNER -PROVIDED 300 ton Trane chillers with secondary economizer coils. Remove (2) old 200 ton York chillers after new chillers are started up and commissioned. Install (2) new OWNER-PROVDED chilled water computer room AC units. Upsize two existing chilled water pumps and install a 3rd new pump Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas ❑ Other: H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised I-4.16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 7 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfin Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 01/25/2017 Print. Name: Joyce Copley Day Telephone: (206) 407-2614 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised I-4.16.docx Revised: January 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT 1 QUANTITY PermitTRAK .;t PAID $3,167.42 M17-0015 Address: 33115 120TH PL 120TH Apn: 1023049078 $3,167.42 MECHANICAL $3,045.60 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $2,403.33 PLAN CHECK FEE R000.322.102.00.00 0.00 $609.12 TECHNOLOGY FEE $121.82 TECHNOLOGY FEE R000.322.900.04.00 0.00 $121.82 TOTAL FEES PAID BY RECEIPT: R10596 $3,167.42 Date Paid: Thursday, January 26, 2017 Paid By: MACDONAL-MILLER FACILITY SOLUT Pay Method: CHECK 4585 Printed: Thursday, January 26, 2017 8:36 AM 1 of 1 CRWSYSTEMS 3 INSPECTION INSPECTION RECORD Retain a copy with permit - 009/5F' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: ZCoZ Type of Inspection: /liS 4rait'eAl, - /A/A1 Address: 3311 5 /2o114Pi Date Called: Special instructions: / ,136: i Date Wanted: /00, crry� n. 5- ilge 7 Requester: , LP 77N C tfill f " Pho a �No: , j j 704= " `K 2'. ` fJi • 0 Corrections required prior to approval. i gri Approved per applicable codes. COMMENTS: a14- MACJ b4 Ji CO- C fjAJ 2 -- CK- s• Ki iTsr /IA P'/ M/YVLA-776.A/ Inspector: Dates _1017 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 17. 0015i Project: 2COL-0 TAcie of Inspection: V - J,i ill Ec)h 1(AL. Address: S311S )20 174 PI Date Called: Special Instructions: Date Wa t d: J/J,7 a.m. ,Qp.m, Reque r: Phone No: 61 Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector: A Ato Date: zo/p7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit. PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: / Z CO -0 Sprinklers: Type of Inspection: f74 Address: Suite #: g33/. 5/ i Contact Person: Special Instructions: Phone No.: r Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -- M76-3 Date: 5// g ii 7 Hrs.: ) . 6 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 PERMIT COORD GAPS PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0015 DATE: 01/26/17 PROJECT NAME: ZCOLO SITE ADDRESS: 3311 S 120 PL - SUITE 120 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: \`3M9 Building Division Public Works P4A WO \ Fire Prevention Structural Planning Division ❑ Permit Coordinator u PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/31/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/28/17 Approved Corrections Required ❑ Approved with Conditions (corrections entered in Reviews) Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 MACDONALD/MILLER FAC SOL INC Hoene Espanol Contact Safety & Health Claims & Insurance Washington State Department of ki Labor & Industries Search L&I Page 1 of 3 A-7 index Help My L&1 Workplace Rights Trades & Licensing MACDONALD/MILLER FAC SOL INC Owner or tradesperson Principals SIMONDS, DERRICK R, PRESIDENT WEBSTER, MARK E, VICE PRESIDENT GEBHARDT, STEPHANIE WETTACH, TREASURER HOEL, STEPHANIE W, MEMBER SIGMUND, FREDRIC, PRESIDENT (End: 01/04/2011) LOVELY, STEVE C, VICE PRESIDENT (End: 01/04/2011) HACK, RICHARD, SECRETARY (End: 01/04/2011) KOPET, TYLER, TREASURER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF EXECUTIVE OFFICER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF OPERATING OFFICER (End: 01/04/2011) GOUGH, DAVID ANTHONY, DIRECTOR (End: 08/29/2014) Doing business as MACDONALD/MILLER FAC SOL INC WA UBI No. 602 254 260 PO BOX 47983 SEATTLE, WA 98106 206-768-4180 KING County Business type Corporation Governing persons FREDRIC 1 SIGMUND STEVE C LOVELY; TYLER C KOPET; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MACDOFS980RU Effective — expiration 12131/2002— 01/04/2019 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS980RU&SAW-= 2/8/2017 m E 2 U_ O u_ - 0 1) L U 1 2 3 4 5 6 7 8 9 10 11 12 13 14 COPYRIGHT © 2016 BURNS & McDONNELL ENGINEERING COMPANY, INC TUKWILA "MIC/H" ZONE — INDUSTRIAL - 81 VD 98168 is 0 0 C 0 1 0p 0 11 (c( ( ATK — OH .. ////////////////////////////////'/i11�1/��/�li�/////�///////�//I�//// / ////////// / / / / / / ? i C / 5 9 AC / / / —U / / / / / / / / / / / / / /////////////////// J AREA OF WORK / / / / / / / / TUKWILA "MIC/H" ZONE — INDUSTRIAL AC F (DEWAI. 0 /////////(/r/I//////////////// OH / / / / / / / / / / / / / /-..—.— / / / / / / - / NEW 300—TON AIR—COOLED CHILLER 1 M PROPERTY LINE FUTURE 300—TON AIR—COOLED CHILLER TUKWILA "MIC/H" ZONE — INDUSTRIAL MIMI IMMO MINIM EXISTING GENERATOR ""-.....-r-- NEW 10'-7" HIGH CMU SCREENWALL (BY OTHERS) Th L_ ACOUSTICAL ANALYSIS UNIT # CH -01,02 (DAY) CH -01,02 (NIGHT) EQUIP. RATED SOUND POWER (DBA) 102 MULT. UNIT FACTOR (DB) EQUIP. LOCATION FACTOR (DB) BARRIER SHIELDING FACTOR (DB) SOUND PATH FACTOR (DB) DIST. TO ADJACENT PROP. (FT) DISTANCE REDUCTION FACTOR (DB) SOUND LEVEL AT SOURCE PROP. (dBA) ZONING OF SENDING PROP. ZONING OF RECEIVING PROP. HOURS MAX. ALLOWABLE SOUND LEVEL (dBA) 3 6 102 3 6 11 11 0 46 31 69 0 46 31 69 MIC/H MIC/H MIC/H 24/7 70 MIC/H 24/7 70 NOTES: 1. ACOUSTICAL ANALYSIS PER AHRI 275-2010. 2. PER CITY NOISE ORDINANCE, MAX SOUND LEVEL OF 70 DBA IS PERMISSIBLEAT ALL HOURS. 3. NOISE SOURCE AND RECEIVING PROPERTY ARE INDUSTRIAL. i I I II II II I I II II II 01; r 1 173 A /, )2 AC TUKWILA "MIC/H" ZONE - INDUSTRIAL II TUKWILA "MIC/H" ZONE — INDUSTRIAL S'f-:PAPA l ..n )aflT v�f �-ti� � � Q iyd..Lo.'J FOR: l achanical 6ectricaJ fumbing Gas Piping City of Tukwila ill. '"° D,VICJON REVISIONS No chances sha!I ho made to the scope of work without prior aptorovai of Tu;:v'iia Building Division. NOTE: Rovic ons wiil rcquiro a rm./ Wan submittal and may in,-;'ude additional plan review fees. FILE CCelf Perm ' No. VAII•0015 Plan r yvi .v c ;•Jproni is subject to errors and omissions. Approval or colds earl o cumcrlts docs not authcllzo the violation of any adopted code or ordinance. Rossipt of approved F Copy and conditi s is acknowledriad: adi 1111 By: Date: City of Tukwila BUILDING DIVISION 1117 oOlff ISSUED FOR PERMIT CITY OF TUKWILA JAN 2 6 2017 PERMIT CENTER no.I date 0 12/22/16 by JS ckd BG description ISSUED FOR PERMIT MacDonald -Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS9B0RU date 12-16-16 designed J SHEEKS detailed J SHEEKS checked B GEZON �lo a Zayo Group Company ZAYO GROUP, LL zCOLO - TUKWILA FA 3311 S 120TH P TUKWILA, WA 981 King County CHILLER UPGRADE P SITE PLAN RyIEWED FOI [�E COMPLIAN APPROVED 68 FEB 0 7 2017 OJEij'Tof Tukwila BUILDING DIVISI project 73166503-00 contract CONTRACT drawing rev. M-603 2 sheet file of sheets .E J Scale For Microfilming 1 2 3 4 5 6 7 8 9 10 11 12 13 14 6 BURNS & McDONNELL ENGINEERING COMPANY, INC COPYRIGHT © 20 DEMO EXISTING PUMPS. EXPANSION TANK —. 10• CWR NO L i 4"CHWS CWR ROUTE OVERHEAD I'DifZ1 DROP DN WALL & ROUTE BELOW RAKED FLOOR. —AR SEPARATOR --- 10• CWR 6x6 ry x 10' CWR O UP )if m v D-3 200 0-2 135 16x16:::.:::::::. Zak v D-2 135 6• c 6• C MEET 6' CV ROO OFC/DH-2 v OPERA 107 200 CFM 0-3 200 STORAGE 118 Bx 6.0 D-1 N 50 a 8x6 R-3 R-3 LL - 4• CWS 6• CWR 6• CWR _10-CWR_. R-4 10.0 IONS $�1 D-2 135 0-2 135 00 D- 10x10 6"CHWS/R 4"CHWS/R E—� i } if clo) ELEV EQUIP. 103 E' R-1 4' CWS R-1 10.5 TLll (T) EF -3 _ CORRIDOR 102 SFD LOBB 100 0-3 240 Y CONF. 117 . V 1' le 1 mooft ALN 16x16 AR v 1- " CHWS/R (IN ULATED) (300 CFM) L 0 a. 1 G-1 200 0-1. 200 G-1 200 v L_- { S 11 D-3 40 Cl 111 75 D-3 240 J'I Il CRAH-6 CRAH-7 L DEDICATED 112 3" FUTURE TAPS 1- L CV -1 /2"CHWS/R C R- CR - 0 — 10 CWS 6' CWR 10 CWS CONNE1CT TO EXIST 3'CHW /R ON MEZZA INE O5 MECH/ ELEC ROUTE 1-1/2"CHW HIGH BELOW ROOF „.I ai 3"CHWS/R .r COLOCATION 111 [FC -5I SEE ,z- 1717SL DM. VDDt�NSATE TO OVED DRAIN -I- -+- 6 /6. - CWS CWR 3"CHWS/R 0 31; tI --DEMO -E-XI-STING CHILLER AFTER NEW CHILLERS ARE �IN TALLED + 6• CWS 6• CWR DE -MO EXISTING CHILLER AFTER NEW CHILLERS ARE INSTALLEELf + 8• CWS (LO 1I) 1 O 0 10 R-5 8• CWR (TOP) 10• CWS (BOTTOM) e e CWR 1 b CWS 0 6i CWR —1 tl'-CWS— 0 <1 .10". CAS 6"-._CWR .._...__ G-2 250 8 O 10 v RECEIVED CITY OF TUKWILA JAN 262017 PERMIT CkNTER ISSUID FOR PEMIT no.date I by I ckd description 0 12/22/16 JS BG ISSUED FOR PERMIT MacDonald -Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU date 12-12-16 designed J SHEEKS detailed J SHEEKS checked B GEZON S010 a Zayo Group Company ZAYO GROUP zCOLO - TUKWILA 3311 S 120TH TUKWILA, WA 9 King County VIEWED FOR AQTLE-PPMPLIANCE PL APPROVED 168FEB 0'7 2011 • 1 /8" - 1'-0" CHILLER UPGRADE lj NTD(VukwI ta I DIVISIO DEMOLITION PL PIPING project 73166503-00 contract CONTRACT drawing M-001 rev. 2 sheet of sheets file 1 12 E 2 Scale For Microfilming 1 2 3 4 5 6 7 8 9 10 11 12 13 14 U z >- z 0 0 (9 z w w z C9 z w J J w z z 0 U z m 0 N 1- > 0 0 0 NEW 3RD PUMP CONNECT TO EXISTING OVERHEAD PIPING HEADERS 6"CHWS 4"CHWS 6"CHWR ROUTE OVERHEAD SUPPLY J CURRENT FLOW: 425 GPM FUTURE POTENTIAL FLOW: 900 GPM ADDITIONAL CAPACITY AVAILABLE: 190 TONS ADDITIONAL DROP DN WALL & ROUTE BELOW RAISED FLOOR. SUPPLY CURRENT FLOW: 425 GPM FUTURE POTENTIAL FLOW: 1906 GPM CAPACITY AVAILABLE: 466 TONS (LIMITED BY RETURN) d CN RETURN CURRENT.... FLOW:.. 434 GPM _.. FUTURE POTENTIAL FLOW: 1166 GPM 1 /2"CHWS/R ROUTE 1-1/2"CHW HIGH BELOW ROOF EXPANSION TANK 3" FUTURE TAPS NISIMMED MINSIMIMP M-601 INSTALL 2 NEW LARGER PUMPS REUSE EXISTING DROPS �NNECT TO EXIST 'CHWS/R ON =ANNE FUTURE MEET ROO -4 6- C 6- C 6- C DEDICATED 112 NEW COMPUTER ROOM CHWS PRESSURE SENSOR 10x12 VFD (TYP) 650 160 CFM) CRAH-8 4` CWS 6' CWR 6• CWR 10:_ CWR CRAH-9 0 6" CWR ELEV EQUIP. Cj EF -3 11 it CORRIDOR 0111111111111111111. - masa . 8X8 160 (TYP 2) 3"CHWS/R COLOCAIWN 16x16 3"CHWS/R SUPPLY CURRENT FLOW: 859 GPM FUTURE POTENTIAL FLOW: 2340 GPM ADDITIONAL CAPACITY AVAILABLE: 0 TONS SEE 7 _17SL 10 FC/DH-4 VESTIBULE 120 CFM SEC C JRED HAIN LI T 41 IRE DEPARTM^ T ACESS ,K .(013' SIeMILAR) TUNNEL. . MAINTAIN FREE ;AIRFLOW °. ° (BY OTHERS). 8 -8'W °x ' 8'-0"H.LOUVER MT <12"'. AB.V °OONc SLAB (TYP; -BY-OTHERS 0 D-311 240 f 4 4 a ROUTE 3." • s F On ATE TO NEARES , = MOVED DRAIN 8" ' R CON ECTED TO EXISTING 10"CWS LINE. II II 6" CHWS8 R II • II II 6• CWR (TOP) 6` CWS (BOTTOM) 8" CWS (LOW) 10` 6` CWR CLOSE VALVES AND CAP FOR FUTURE. U 8" ' CHWS& -"�- CLOSE VALVES. AND CAP FOR FUTURE. 8" CHWS CONCRETE PAD TYP, BY OTHERS) ANCHOR POINT W/'.N`EOPREI E ISOLATOR (TYP) SEE CHILLER SUB ITTAL . FO EXACT LOCATION 4 m 6 .: OP) 10 CWS (BOTTOM) i 8" CHWS CONNECTED TO EXISTING 10" CHWS LINE ROUTE NEW 8" CHWS LINE ABOVE EXISTING CHWS LINE ALONG BUILDING 4 4 EXISTING GENERATOR NCII II NC 00 `S' 4. RECEIVED CITY OF TUKWILA JAN 2 6 2017 ER' ' IT CENTER NEW 300 -TON AIR -TOOLED CHILLER (TYP) `/ 4 . PROVI[ E LOUVER INSTA(LED LIKE DOUBLE DOORITH HARD ARE TO BAR AN LOCK FROM INSIDE ENCLOSU E. (PROV DED AND INSTALLED BY OTHE S.) NEW 10'-7" HIGH SCREENWALL (BY OTHERS) ISSUED FOR PERMIT 1 /8" - .. t1 no.I date 0 12/22/16 by JS ckd BG description ISSUED FOR PERMIT MacDonald -Miller iller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU date 12-12-16 designed J SHEEKS detailed J SHEEKS checked B GEZON S010 a Zayo Group Company REVIEWED FO -+ ZAYO GROUP, L ODE COi�PLIAN� APPROVED zCOLO - TUKWILA FA`,ILIT��CB 07 2011 3311 S 120TH Pitst TUKWILA, WA 981p8 King County City of Tukwila CHILLER UPGRADE PR CT GROUND LEVEL PLAN - SOUTH PIPING project contract 73166503-00 I CONTRACT drawing rev. M-102 - 2 sheet of sheets file CONF. 117 4 ,• o S:. Fg4. Ch 3 ® 16x16 o r ,-- %" CHWS/R (IN.ULATED) �V' 8X8 160 (TYP 2) 3"CHWS/R COLOCAIWN 16x16 3"CHWS/R SUPPLY CURRENT FLOW: 859 GPM FUTURE POTENTIAL FLOW: 2340 GPM ADDITIONAL CAPACITY AVAILABLE: 0 TONS SEE 7 _17SL 10 FC/DH-4 VESTIBULE 120 CFM SEC C JRED HAIN LI T 41 IRE DEPARTM^ T ACESS ,K .(013' SIeMILAR) TUNNEL. . MAINTAIN FREE ;AIRFLOW °. ° (BY OTHERS). 8 -8'W °x ' 8'-0"H.LOUVER MT <12"'. AB.V °OONc SLAB (TYP; -BY-OTHERS 0 D-311 240 f 4 4 a ROUTE 3." • s F On ATE TO NEARES , = MOVED DRAIN 8" ' R CON ECTED TO EXISTING 10"CWS LINE. II II 6" CHWS8 R II • II II 6• CWR (TOP) 6` CWS (BOTTOM) 8" CWS (LOW) 10` 6` CWR CLOSE VALVES AND CAP FOR FUTURE. U 8" ' CHWS& -"�- CLOSE VALVES. AND CAP FOR FUTURE. 8" CHWS CONCRETE PAD TYP, BY OTHERS) ANCHOR POINT W/'.N`EOPREI E ISOLATOR (TYP) SEE CHILLER SUB ITTAL . FO EXACT LOCATION 4 m 6 .: OP) 10 CWS (BOTTOM) i 8" CHWS CONNECTED TO EXISTING 10" CHWS LINE ROUTE NEW 8" CHWS LINE ABOVE EXISTING CHWS LINE ALONG BUILDING 4 4 EXISTING GENERATOR NCII II NC 00 `S' 4. RECEIVED CITY OF TUKWILA JAN 2 6 2017 ER' ' IT CENTER NEW 300 -TON AIR -TOOLED CHILLER (TYP) `/ 4 . PROVI[ E LOUVER INSTA(LED LIKE DOUBLE DOORITH HARD ARE TO BAR AN LOCK FROM INSIDE ENCLOSU E. (PROV DED AND INSTALLED BY OTHE S.) NEW 10'-7" HIGH SCREENWALL (BY OTHERS) ISSUED FOR PERMIT 1 /8" - .. t1 no.I date 0 12/22/16 by JS ckd BG description ISSUED FOR PERMIT MacDonald -Miller iller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU date 12-12-16 designed J SHEEKS detailed J SHEEKS checked B GEZON S010 a Zayo Group Company REVIEWED FO -+ ZAYO GROUP, L ODE COi�PLIAN� APPROVED zCOLO - TUKWILA FA`,ILIT��CB 07 2011 3311 S 120TH Pitst TUKWILA, WA 981p8 King County City of Tukwila CHILLER UPGRADE PR CT GROUND LEVEL PLAN - SOUTH PIPING project contract 73166503-00 I CONTRACT drawing rev. M-102 - 2 sheet of sheets file Scale For Microfilming 1 2 3 4 5 6 7 8 9 10 11 12 13 14 NEW 3RD PUMP CONNECT TO EXISTING OVERHEAD PIPING HEADERS C iG7) NO NEW MECHANICAL WORK REQUIRED BEYOND THIS POINT UNDER PHASE 1 RETURN CURRENT FLOW: 0 GPM FUTURE POTEI\TIAL FLOW: 1481 GPM s" CWS 4" CWR 6"CHWS 6"CHWR D-2 135 ROUTE OVERHEAD 0-2 135 VCD-04 V'=D-03 D-3 200 0-2 135 VC D-02 m WY INSTALL 2 NEW LARGER PUMPS REUSE EXISTING DROPS 0-3 200 CC 1 v 0 0 0 STOO1c7-731 115 6"A 501 �• tt�Sll C 1=1F 6x6 ll R-3 N y 4- CWS 6" CWR 6• CWR 10" SWR 0 CRAH-8 1 D-2 135 0111011111111 D-,2 13 1 E3 8" CWR UN.CCUPIED 6—CWS DROP DN WALL & ROUTE BELOW RAISED FLOOR. 8" CWR &--CWS NO N6W MECHANICAL WORK REQUIRED BEYOND THIS POINT UNDER PHASE 1 SUPPLY CURRENT FLOW: 0 GPM FUTURPOTENTIAL FLOW: 1481 GPM ADDITIONAL CAPACITY AVAILABLE: 592 TONS ADDITIONAL HEAD AVAILABLE: 32 FT RETURN CURRENT FLOW: 434 GPM MAX FLOW: 1600 GPM SUPPLY CURRENT FLOW: 425 GPM FUTURE POTENTIAL FLOW: 900 GPM NAL CAPACITY AVAILABLE: 190 TONS 10x10 i NEW COMPUTER ROOM AIR HANDLER (TYP 2) 6"CHWS/R 3"CI-WS&R M-601 CRAH-9 3"CHWS&R CHWS PRESSURE SENSOR ISHNIINOIS DEDICATED 112 ADDITIONAL 4811414Z4,,- SUPPLY CURR NT FLOW: 425 GPM FUTURE POTENTI L FLOW: 1906 GPM CAPACITY AVAILABLE: 466 TONS (LIMITED BY RETURN) RETURN CURB NLELOW:_434 GPM FUTURE POTENTIAL FLOW: 1166 GPM 0111111111011 UP C 36X36EC RETURN 1 240W TM0.01 3" FUTURE TAPS 01111111111110 C3 R-5 ®Ru5 32X14 TOGD (TYP 4) �r- N 1 /2"CHWS/ R CONN a T TO EXIST 3"CHW•/R ON MEZZA I N E 0 a 0 0 C� ROUTE ALONG MEZZANINE FLOOR AND DROP DOWN INTO UPS ROOM. ry --- FAN COIL MOUNTED ON MEZZANINE ABOVE. SEE til STRUJt.ThURAL DRAWINGS C ROUTE 1-1 /2"CHWS/R HIGH BELOW ROOF TO FCU—M01 7.5 4"CHWS/R v CORRIDOR v ELEV EQUIP. 103 EF -3 D-3 240 a R-4 CONNECT T 'FUTURES. Tll 10.0 3" P 4. R-1 CONF. 117 G-1 200 v m v G-1 200 ROUTE 3 " S SATE TO " NEARESt I 0VED DRAIN 3"CHWS/R 0 —R -- COLOCATION 111 1 CR - 0 10 R-5 10 R-5 0 1 0 SUPPLY CURRENT FLOW: 859 GPM FUTURE POTENTIAL FLOW: 2340 GPM ADDITIONAL CAPACITY AVAILABLE: 0 TONS 10 R-5 16" C O 114 6" CWR �• CWS to 6 CWR et ,►" C� CWR VESTIBULE CWS 15 EF 5 <r ENI — 8x8 1 (EF -5 ISSUED FOR PERMIT 10 17 Dols RECEIVED CITY OF TUKWILA JAN 262011 PERMIT CENTER no. date I by 0 12/22/16 JS ckd BG description ISSUED FOR PERMIT MacDonald -Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU date 12-12-16 designed J SHEEKS detailed J SHEEKS checked B GEZON S010 a Zayo Group Corypacy— REVIEWED FOR )C kCpORM�PLIANCE FACILITY VED -I PLFEB 0 7 2011 98168 Y City of Tukwila ZAYO GROU zCOLO - TUKWIL 3311 S 120T TUKWILA, WA King Coun 1/8" - ft UIILLMINc' CHILLER UPGRAD r. .,- GROUND LEVEL PLAN - NORTH PIPING project 73166503-00 contract CONTRACT drawing rev. M-103 2 sheet of sheets file Scale For Microfilming 1 2 3 4 5 6 7 8 9 10 11 12 13 14 • 1 SEC C .................... ( I) EF -3 CORRIDOR 102 D-3 240 4 , SFD LOBB" 100 U D-3 240 a 6EPARTIA.ENT D ,FI -RE ACCESS CAIN L14(Of SIMILAR) TUNNEL TO, MAINTAIN MAINTAIN FREE gAIRFCOW 17_ ° (BY OTHERS) r4: a A <1 4 ' 1 u °a 4. . 4 4 8 - 8"°'W "x 8,f —0"H &LO LA/EB MT, 1,12`"d ARV. aGONC 4 SLAB (TY'BY OTHERS) 4 cm, ANCHOR POINT IN/ .N-EQPREVE ISOLATOR (TYP) SEE CHILLER SUBMITTAL FOR EXACT LOCATION COPYRIGHT © 2016 BURNS & McDONNELL ENGINEERING COMPANY, INC. 4 a- 4 a .14x1 w 1" FC/DH-4 R-1 R-1 (! J ter Y�;.ivr.�4 10 (300 to L 0 r 0 16x16 14x12 \3 3 3/4." CHWS/R (INSULATED) CFM) 10"0 )16x16 SFD J 6"0 l 4 4 n M-401 a4 a 4 d a d 4 4 4 e c 4 4 4, 4 CONCRETE PAD TYP, BY OTHERS) d 4 3'-4Y" 4 �.I �D-3�_� 240 i 1 0) -co 120 CFM G-1 200 200 10"0 im 12x12 R-4,11 16x10 10 CDcC) SF -- 4 4 es 71 a r> a 6" CHWS&R CON�NECTIO TO- CHILLER a a a .EX ,, .., ,VAULT. 4 a 4 n 4 a 4 a a ,1 a A , e a 4 ° 4 e a 4 a. 4y 4 4 4 ° 1' -On'' A V , O d 41 4 a a rSTI NG ACCESS° , U n_ d A 4 da , ° v A a ' - 4 a an n . 4 a ° _ a. a, 4 4 a d !i FUTURE, 4 a 4 4 4 n ° :I .:1 a a a r' ii° ° - a u 4 [1 a a d a 4A a '4 a `' 4 a 4 a • n 4a a n4 d .. a. 4 4 4 a FIBER• 111 a �.a 4 CH..'0, 1 a f A a A' d' 44 A a e 4q a a. 4 A a , • 4 fie. ' a • 4 A a 41 8X8 160 (TYP 2) 12X1OSL — 10" CWR DH -5 i FC -5 SLOPE ROUTE 3/4" CONDENSATE TO NEAREST APPR EERIS N (EH) 8" '' R CON 1 EXISTING 10" C II M-401 10'-2" 1 a 17X17SL SEE -E=} ECTED TO WS LINE. " CHWS4R 4 41 e 4 44 , 4 d a 4 a 4 6ff CHWS&R `C0NN,ECTION, TO 0CHILLER 4 4 4 ' Al • 4 a 4 a a d' 4 a d 41 a 4. CH --02 a 4 .a4 n - A e 0 a e 44 4 0 ° a a a 4a a ' s 4. 41 a C 4 4 J a'4 • e 4a a 4 A a4 4 a 11 �7 - : 1 10'x, NC CHWS& ,f 6" CWR (TOP) 6" CWS (BOTTOM) COLOCATION 111 no.I date 0 12/22/16 by JS ckd BG description ISSUED FOR PERMIT CURRENT FUTURE POTENTIPL ADDITIONAL CAPACITY A\ .aye J, e.su .\...w,�.w.,. ,w.1.L<..+.1..... 1, r ....... ....i'.v1... ...,.1..:. w? �.x 8" CWS (LOW) 1.t• lett Do - —0— —0— CLOSE . VALVES AND CAP FOR FUTURE. ,.. . ' / 4 „ 4. 4° .0 4 4 n a. 1 e a a e v 4 4. 4 a 4 a ., .4 a .° 4 a 4 a ., a a n a 4 a • a a d d 4 41 4 a ° o ° ° :] a A a 4 a .4 A d 4 ,.. 4 A a '.,1 a d 4 a 4 `1'7 4 d a .. •� d a 4 d a a � 4 4. .1 a .d n 4"a4 a 0. 4 a qa a - ..• d. 4' 4 d 4 a 4 d a d .4 4 4' a 4 4 d a 4 d a • 4 ° a d d. ` • a '. J 4. a 4 . a 4 4 d A 4 da , ° v 1 �y C,H 0 3 !i FUTURE, 4 a 4 4 4 n ° :I .:1 a a a r' ii° ° - a u 4 [1 a a d a 4A a '4 a `' 4 a 4 a • n 4a a n4 d .. a. 4 4 4 fa —0— !\1 1Y4" `/ CLOSE VALVES . AND CAP FOR FUTURE. A J 4. A 4 7' 8" 8" CHWS 8" —11%4" NEW 300—TON AIR—COOLED CHILLER (NP) LIKE DOUBLE DOOR WITH HARD\A'ARE TO BAR AN LOCK FROM INSIDE ENCLOSU E. (PROV DED AND INSTALLED BY OTHE S.) 4 4 -4- EXISTING GENERATOR SCREENWALL (BY OTHERS) FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU ISSUED FOR PERMIT 17% 00 RE CITY 0 JAN PERMIT CENTER date 12-12-16 designed J SHEEKS detailed J SHEEKS checked B GEZON King County D FOR zCOLO - TUKWILA F CRILERTWE0 ZAYO GROUP, LC APPROVED City 0 f 1-7 2u kwi I a 3311 S 120TH L TUKWILA, WA 98 68 NG DIVISICIN a Zayo Group Company CHILLER UPGRADE PROJECT ENLARGED EQUIPMENT YARD PLAN PIPING project 73166503-00 contract CONTRACT drawing M-101 rev. 2 sheet of sheets file E 2 C) E LE2L 0 a_ ' _0 (0 v/ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 AREA OF WORK r ----- — ---- ---- I 1 ..L .1 .. 1 1. .1..L _1. -1. J. _L 1_ 1. .1 .1. J.. . 1 _1 1 -Ni--- T-----ai malltrera1/4TOMEMIL ma—z-- [L ..LLrl.r17.1T_LT-, l.T TL .L 1 . 2 .I -.L. rar l I 1� X 1 1 1 1 1 1 i� --- -- - -- LT1T_I_rt 1_rL.T.LT_Lf..1.r1.Tl_T_11.1T.L1_LL.L.T.L1.1T_L1._Lr.1.rL.T.. ..rL-r-1T1T.Lr1Tlr1-1-1_TIT_L1-1 alennilinr JUIRIMUL ------ ----- 1 1 NEW AIR-COOLED CHILLER WITH WATERSIDE ECONOMIZER BEHIND SCREENWALL SOUTH ELEVATION M-301 1/16" = ,t 1111111111111 WNW INIrrirainsmnr T- lilt — - — — --- -- -- ----- ---- 11..1 .1..1..1. L.1..1.1 .1. 1. 1 L1. 1 .1. 1. .11 .L.L1; 17�irr��i tTii�I I1lTT,T -. L...1 L L ...L ..L.. ..... ..... i1:11.1.L-11.1.L1.1.11.LL1.1- FUTURE AIR-COOLED CHILLER WITH WATERSIDE ECONOMIZER BEHIND SCREENWALL MINN T' -- — ---------ilifilliiiili - Ilnurammuulighndismadhahnniallminr — - - T T — MNr --- ----- 1 I r -- ! 1 1 rJ��11., .1..... _ L �: -- ------------- C CTLT1- I T I 'TT;L, 7 -I'- - Ti1J .1-1.1..1 .1. L1,1 7 1 1. 1- 1- 1 1- -- 1_L .l. 111.111111111111101 11111 MI 1 - 1 1 .1. .1 MEM 9ClIl-�1ii� Lii�L� is'ill �NIII-- -- - 1 1. _L L L,_l.._i_ 1 -1. 1_.1 _L. - Mall 1, 1 1 1 1 1 1 1 1 7 1 1 1 I I I I I I I 1 1 l I 1 1 7 I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1'1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 I 1 1 I I 1 1 1 1 1 1 1 .i.11.r1-rl-IFLI71,-�11 41-1-4111.LrJ. .1.7.17 41-1-'41-171'T.I.�..1.r1-r11.1711-1T-Lr-1.11-1-LTL LTITI-1711-E-11-11[.171-r1-171-I.LI.�11T.1.TJ.r1._rlrl.rLlJ LT1r.l-1-r,-•.1L-T'LTLTl-11-11-r1rLr1T1T1-r1- T1-rJ- ISSUED FOR PERMIT oo RECEIVED CITY OF TUKWILA JAN 262017 PERMIT CENTER no. I date I by ( ckd I description 0 12/22/16 JS BG ISSUED FOR PERMIT MacDonald -Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS9B0RU date 07-11-16 designed J SHEEKS detailed J SHEEKS checked B GEZON S010 a Zayo Group Company ZAYO GROUP, LL zCOLO - TUKWILA FA 3311 S 120TH PL TUKWILA, WA 981 King County CHILLER UPGRADE PR ELEVATIONS PIPING REVIEWED FOF ODEPPROdED °✓E A ILITY FEB 01 2011 F G H 8 City of Tukwila project contract 73166503-00 CONTRACT drawing M-301 rev. 2 sheet of sheets file Scale For Microfilming 1 2 3 4 5 6 7 8 9 10 11 12 13 14 z COPYRIGHT © 2016 BURNS & McDONNELL ENGINEERING COMPANY, 8" CHWR FROM CRAH COOLING COILS SEE PLANS 8" FUTURE 10" CHWR FROM COOLING COILS 10" NC NO 6" 6" CHWR FROM FCU & CRAH COOLING COILS SEE PLANS 10" -- J NO 3/4" BYPASS 1" CAPPED LINE FOR FUTURE COMPUTER ROOM UNIT HUMIDIFIERS \-- 3/4" PRESSURE REDUCING VALVE (SET AT 12 PSI) 3/4" GLYCOL FILL CONNECTION B&G SEDIMENT SEPARATOR MODEL SRS -10 AIR PRESSURE PRE-SET AT 12 PSI B&G EXPANSION TANK MODEL B-200 (53 GAL VOLUME, 53 GAL ACCEPT) BLADDER TYPE EXP TANK PIPE DRAIN TO FLOOR SINK I El— NC i I NC 10" 1" CW MAKE-UP AND FILL LINE FROM COLD WATER LINE IN MECH ROOM SEE PLUMBING SHEETS -i- NCiC INC NOi4 ' NO - —I-1— — NOI LINO 6" (TYP) NEW AIR-COOLED CHILLER WITH WATERSIDE ECONOMIZER (TYP 2) MECHANICAL ROOM FLOOR PIPING TO CONNECT THRU ROOF OF ECONOMIZER VESTIBULE SEAL WEATHER -TIGHT (TYP 2) MOTORIZED 2 -WAY CONTROL VALVE (BY CONTROLS CONTRACTOR) 6„ (TYP 2) l 1- CH -01 ROUTE PIPING INSIDE CHILLER TO MODIFIED CONNECTION POINT (TYP) FUTURE CHILLED WATER PUMP — CHWR — I rs P-04 CONCRETE FILLED INERTIA BASE (TYP) PUMP ROOM SCHEMATIC M-401 NO SCALE 10" CHWR FROM PUMPS mi TIE INTO EXISTING —4 CAPPED CHWR J EXISTING CHWR THRU EXTERIOR WALL J) J.. - l 1- CH -01 ROUTE PIPING INSIDE CHILLER TO MODIFIED CONNECTION POINT (TYP) FUTURE CHILLED WATER PUMP — CHWR — I rs P-04 CONCRETE FILLED INERTIA BASE (TYP) PUMP ROOM SCHEMATIC M-401 NO SCALE 10" CHWR FROM PUMPS mi TIE INTO EXISTING —4 CAPPED CHWR J EXISTING CHWR THRU EXTERIOR WALL NEW 6" CONCRETE HOUSEKEEPING PAD W/ LEVEL TOP (BY G.C.) (TYP) CH -02 PIPE STANCHION (TYP) ANCHOR TO SLAB PER STRUCTURAL NEOPRENE ISOLATOR (TYP) SEE PLANS FOR LOCATION ATTACH TO PAD PER STRUCTURAL CONCRETE PAD INSIDE SCREENED AREA (BY G.C.) 1 P-03 1 TYP NCrC INC 10" NCI 1)°11 NC —1� NC SET T&P VALVE TO 100 PSI PIPE FULL SIZE TO FLOOR SINK 5 GALLON POT FEEDER, SECURE TO WALL AT 36" A.F.F PIPE TO FLOOR SINK EXISTING CONCRETE PAD TO CHILLERS P-02 P-01 INSTALL PUMP P-03 FIRST, NEW CHILLED WATER PUMP THEN SHUT DOWN AND DEMO (TYP 3) P-02 AFTER P-03 IS OPERATIONAL INSTALL P-01 LAST PIPING & STANCHION LOCATION SHOWN DIAGRAMATICALLY FIELD -ROUTE AS REQUIRED CH-03 OUTDOOR CHILLER AREA SCHEMATIC M-401 NO SCALE 8" -\ SPRING ISOLATOR ANCHOR TO PAD PER STRUCTURAL (TYP) 10" CHWS TO CRAH UNITS TEMP SENSOR EXISTING CHWS THRU EXTERIOR WALL FUTURE AIR-COOLED CHILLER WITH WATERSIDE ECONOMIZER (TYP 2) NEW CHWS LINE MOUNTED ABOVE EXISTING LINE CH -04 8" CHWS TIE INTO EXISTING ---a CAPPED CHWS A CHWS A ISSUED FOR PERMIT RECEIVED CITY OF TUKWILA JAN 2 6 2017 PERMIT CENTER no.I date I by ckd description 0 12/22/16 JS BG ISSUED FOR PERMIT MacDonald -Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU date 12-16-16 designed J SHEEKS detailed J SHEEKS checked B GEZON 2C0110 a Zayo Group Company ZAYO GROUP, LL zCOLO - TUKWILA FA 3311 S 120TH PI TUKWILA, WA 981 8 King County IEWED FOF. COMPLI/0=5 APPROVED FEB 07 2017 CHILLER UPGRADE PRJaraff of Tukwila BUILDING DIVISI DIAGRAMS PIPING 3N project contract 73166503-00 I CONTRACT drawing rev. M-401 2 sheet of sheets file J J. Lk NEW 6" CONCRETE HOUSEKEEPING PAD W/ LEVEL TOP (BY G.C.) (TYP) CH -02 PIPE STANCHION (TYP) ANCHOR TO SLAB PER STRUCTURAL NEOPRENE ISOLATOR (TYP) SEE PLANS FOR LOCATION ATTACH TO PAD PER STRUCTURAL CONCRETE PAD INSIDE SCREENED AREA (BY G.C.) 1 P-03 1 TYP NCrC INC 10" NCI 1)°11 NC —1� NC SET T&P VALVE TO 100 PSI PIPE FULL SIZE TO FLOOR SINK 5 GALLON POT FEEDER, SECURE TO WALL AT 36" A.F.F PIPE TO FLOOR SINK EXISTING CONCRETE PAD TO CHILLERS P-02 P-01 INSTALL PUMP P-03 FIRST, NEW CHILLED WATER PUMP THEN SHUT DOWN AND DEMO (TYP 3) P-02 AFTER P-03 IS OPERATIONAL INSTALL P-01 LAST PIPING & STANCHION LOCATION SHOWN DIAGRAMATICALLY FIELD -ROUTE AS REQUIRED CH-03 OUTDOOR CHILLER AREA SCHEMATIC M-401 NO SCALE 8" -\ SPRING ISOLATOR ANCHOR TO PAD PER STRUCTURAL (TYP) 10" CHWS TO CRAH UNITS TEMP SENSOR EXISTING CHWS THRU EXTERIOR WALL FUTURE AIR-COOLED CHILLER WITH WATERSIDE ECONOMIZER (TYP 2) NEW CHWS LINE MOUNTED ABOVE EXISTING LINE CH -04 8" CHWS TIE INTO EXISTING ---a CAPPED CHWS A CHWS A ISSUED FOR PERMIT RECEIVED CITY OF TUKWILA JAN 2 6 2017 PERMIT CENTER no.I date I by ckd description 0 12/22/16 JS BG ISSUED FOR PERMIT MacDonald -Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU date 12-16-16 designed J SHEEKS detailed J SHEEKS checked B GEZON 2C0110 a Zayo Group Company ZAYO GROUP, LL zCOLO - TUKWILA FA 3311 S 120TH PI TUKWILA, WA 981 8 King County IEWED FOF. COMPLI/0=5 APPROVED FEB 07 2017 CHILLER UPGRADE PRJaraff of Tukwila BUILDING DIVISI DIAGRAMS PIPING 3N project contract 73166503-00 I CONTRACT drawing rev. M-401 2 sheet of sheets file J Scale For Microfilming () E a) 0 C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 z a 0 0 0 z tz L w z 0 z w J J w z z 0 0 U 025 z CO 0 > N 0 1- a 0 0 8" -\8" CHWR FROM CRAH COOLING COILS SEE PLANS 10" FUTURE 10" CHWR FROM COOLING COILS NO NC 6" 6" CHWR FROM FCU & CRAH COOLING COILS SEE PLANS J NO 3/4" -\5 AIR PRESSURE PRE-SET AT 12 PSI B&G EXPANSION TANK MODEL B-200 (53 GAL VOLUME, 53 GAL ACCEPT) BLADDER TYPE EXP TANK 0-- 3/4" BYPASS 1" CAPPED LINE FOR FUTURE COMPUTER ROOM UNIT HUMIDIFIERS \- 3/4" PRESSURE REDUCING VALVE (SET AT 12 PSI) 3/4" GLYCOL FILL CONNECTION NO N0 3/4" /i t i 1" CW MAKE-UP AND FILL LINE FROM COLD WATER LINE IN MECH ROOM SEE PLUMBING SHEETS B&G SEDIMENT SEPARATOR MODEL SRS -10 - NO E NC I I NC PIPE DRAIN TO FLOOR SINK -r NC�� INC I NO I L NO -- -1--- -- -�-- N01 I NONC I C mi NC -1 NC i I NC 1 NC SET T&P VALVE TO 100 PSI PIPE FULL SIZE TO FLOOR SINK 5 GALLON POT FEEDER, SECURE TO WALL AT 36" A.F.F DEMOLISH EXISTING PUMP 1 & 2 AFTER NEW PUMPS ARE INSTALLED AND TESTED EXISTING CONCRETE PAD TO CHILLERS MECHANICAL ROOM FLOOR PUMP ROOM SCHEMATIC - DEMO M-402 NO SCALE 10" CHWR FROM PUMPS EXISTING CHWR THRU EXTERIOR WALL DEMOLISH EXISTING AIR-COOLED CHILLER AFTER NEW CHILLERS ARE INSTALLED & OPERATIONAL (TYP 2) CONCRETE PAD INSIDE SCREENED AREA (BY G.C.) x xx xx XX xx xx xx 4( 4(< x>bNxxxxxxxxxxxxxixxlx xxxxxxxxxxxxxxxxxx CH -01 CHILLER AREA SCHEMATIC - DEMO NO SCALE P-02 P-01 CH -02 10" CHWS TO CRAH UNITS TEMP SENSOR EXISTING CHWS THRU EXTERIOR WALL CHWS A M17 0 VC. ISSUED FOR PERMIT RECEIVED CITY OF TUKWILA JAN 262017 PERMIT CENTER no.I date 0 12/22/16 by JS ckd BG description ISSUED FOR PERMIT MacDonald -Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU date 12-16-16 designed J SHEEKS detailed J SHEEKS checked B GEZON 2C010 a Zayo Group Company ZAYO GROUP zCOLO - TUKWILA 3311 S 120TH PL EB 07 2017 TUKWILA, WA 9 16 King County EVIEWED FOR MPLIANCE ROVED CHILLER UPGRADE City of TLt%w1I 1 :t o 63 DIVISION DEMOLITION DIAGRAMS PIPING project contract 73166503-00 I CONTRACT drawing rev. M-402 2 sheet of sheets file a) m E rn c E 0 U 0 u-. m 0 U 1 2 3 4 5 6 7 8 9 10 11 12 13 14 CHILLERS: (2) NEW AIR-COOLED CHILLERS WILL BE INSTALLED IN THE EXPANDED OUTDOOR CHILLER YARD. THE CHILLERS WILL BE CONNECTED TO EXISTING PIPING IN THE YARD. THE EXISTING (2) CHILLERS WILL BE DEMOLISHED AFTER THE NEW CHILLERS ARE INSTALLED AND OPERATIONAL. THERE WILL BE PROVISIONS FOR (2) FUTURE AIR-COOLED CHILLERS TO BE PLACED IN THE YARD. PUMPS: (3) NEW CHILLED WATER PUMPS WILL BE INSTALLED IN THE INDOOR MECHANICAL ROOM ON THE EXISTING PUMP PAD. THE EXISTING (2) PUMPS WILL BE DEMOLISHED AFTER THE NEW PUMPS ARE INSTALLED AND OPERATIONAL. THERE WILL BE A PROVISION FOR (1) FUTURE CHILLED WATER PUMP. COMPUTER ROOM AIR HANDLERS: (2 NEW CHILLED WATER COMPUTER ROOM AIR HANDLERS (CRAHS) WILL BE INSTALLED INSIDE THE DATA CENTER. THE CRAHS WILL BE CONNECTED TO THE EXISTING CHILLED WATER PIPING AND WILL DISTRIBUTE COLD AIR THROUGH THE RAISED FLOOR AREA. >- z 0 0 z w w z (9 z w J J LIJ z z 0 U 025 z CO co 0 N O . 0 0 0 SPRING - HANGERS THIN 20' BUTTERFLY VALVE PRESSURE GAUGE (0-60 PSI) FLEX CONN SUCTION DIFFUSER W/ STRAINER BALL VALVE W/ 3/4" HOSE ADAPTOR PIPE SUPPORT VICTAULIC VENTURI-CHECK OR EQUIVALENT TAP FLEX CONN REDUCER IF REQUIRED CONCRETE FILLED INERTIA BASE 2" DEFLECTION SPRING ISOLATORS BOLT ISOLATORS TO PAD EXISTING CONCRETE HOUSEKEEPING PAD BASE -MOUNTED END SUCTION PUMP DETAIL P&T TAP (TYP) SEISMIC SUPPORT STAND PROVIDED W/ UNIT BALL VALVE (TYP) COMPUTER ROOM AIR HANDLER ?--CHWS -CHWR-1):11 A CIRCUIT SETTER 1/2" CAPPED HOSE BIBB FITTINGS FOR DRAIN & SYSTEM FILL (TYP 3) 1" CONDENSATE DRAIN CONNECT TO HUMIDIFIER SUPPLY CONNECT TO 3/4" DRAIN 3/4" SECONDARY DRAIN COMPUTER ROOM �- RAISED FLOOR T / IX II 1/2" TRAP PRIMER VALVE COMPUTER ROOM AIR HANDLER DETAIL N.T.S. FITTING GENERAL NOTES PIPING MATERIAL SCHEDULE: PIPING I CHILLED WATER SIZE 1/2" - 2" 2-1/2" - 10" 12"+ MATERIAL COPPER TYPE L SCH 40 BLK STL ASTM A53 A OR B STD WT BLK STL ASTM A53 A OR B JOINT LEAD FREE PRESSED GROOVED, BUTT WELDED GROOVED, BUTT WELDED SOLDER MECH JOINT FLANGED, FLANGED, PIPING INSULATION SCHEDULE PIPING TYPE PIPE SIZE INSULATION TYPE INSULATION THICKNESS CONDUCTIVITY RANGE CHILLED WATER COOLING (40°-60°F) 1/2" - 1-1/4" 1-1/2"+ FIBERGLASS, ARMAFLEX 1/2" 1" 0.21 - 0.27 0.21 - 0.27 FIBERGLASS, ARMAFLEX - ALL PIPING INSULATION AND COVERINGS SHALL HAVE AN ASTM FLAME SPREAD RATING OF 25 OR LESS AND AN ASTM SMOKE DEVELOPED RATING OF 50 OR LESS. - ELASTOMERIC INSULATIONS SHALL BE CLOSED CELL. - ELASTOMERIC INSULATIONS WHICH MEET THESE RATINGS MAY BE USED AS A SUBSTITUTE FOR FIBERGLASS. - PROVIDE A VAPOR BARRIER COVERING ON ALL CHILLED WATER PIPING AND COIL CONDENSATE PIPING INSULATION. - PROVIDE A COVERING FOR ALL FIBERGLASS INSULATION WITHIN THE BUILDING. - PROVIDE A VINYL JACKET FOR ALL INSULATION EXPOSED TO SIGHT WITHIN THE BUILDING EXCEPT MECHANICAL ROOMS. - PROVIDE REMOVABLE LACED INSULATION PAD OVER ALL CONTROL VALVES, WHERE NOT LOCATED WITHIN A MECHANICAL ROOM. - PROVIDE ALUMINUM JACKET ON ALL INSULATED PIPING OUTSIDE BUILDING. - AT PIPE HANGERS PROVIDE RIGID INSULATION BETWEEN PIPE AND HANGER. 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE MECHANICAL CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2015 INTERNATIONAL BUILDING CODE (IBC), INTERNATIONAL MECHANICAL CODE (IMC), AND UNIFORM PLUMBING CODE (UPC) AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 4. SLOPE ALL INDIRECT DRAINS AT 2% UNLESS OTHERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM THE CODE AUTHORITY BEFORE INSTALLING PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS). 5. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2015 IMC AND IBC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 6. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 7. PROVIDE CHROME PLATE ESCUTCHEON PLATES AT ALL EXPOSED WALL AND CEILING PENETRATIONS. 8. PROVIDE SHUT-OFF VALVES AT ALL EQUIPMENT CONNECTIONS. 9. PROVIDE UNION, GROOVED OR FLANGED CONNECTION AT EQUIPMENT FOR FUTURE REMOVAL AND SERVICING. 10. FOR CONDENSATE PIPING PROVIDE TRAPS WITH A MINIMUM SEAL 2" GREATER THAN THE FAN OPERATING STATIC PRESSURE AT ALL COOLING COIL CONNECTIONS. 11. PROVIDE MINIMUM 1" AIR BREAK FOR ALL CONDENSATE PIPE TERMINATIONS AT DRAINS. 12. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. 13. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR. COORDINATE ELECTRICAL SUPPLY FOR HEAT TRACE WITH ELECTRICAL CONTRACTOR. 14. TRENCHING, BACKFILLING AND COMPACTING FOR UNDERGROUND PIPING SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR UNLESS STATED OTHERWISE IN CONTRACT DOCUMENTS. ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD-MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE-UP AIR NOMINAL OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START/STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2015 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2015 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2015 WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS - DUCT WRAP, WHERE INDICATED, SHALL BE 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER. - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM. - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT. - SUPPLY DUCT WHICH CONVEYS SUPPLY AIR AT TEMPERATURES LESS THAN 55 DEG F OR GREATER THAN 105 DEG F WHEN LOCATED IN CONDITIONED SPACE SHALL BE INSULATED WITH A MINIMUM OF R-3.3 , WHEN LOCATED IN UNCONDITIONED SPACE R-6 AND WHEN LOCATED OUTSIDE THE BUILDING R-8 (CLIMATE ZONE 4) OR R-12 (CLIMATE ZONE 5) PER WSEC C403.2.8.2. - OUTSIDE AIR DUCT INSULATION SHALL MATCH BUILDING ENVELOPE INSULATION VALUES UNLESS SERVING INDIVIDUAL SUPPLY AIR UNITS WITH LESS THAN 2800 CFM OF TOTAL SUPPLY AIR CAPACITY, PROVIDED THESE ARE INSULATED TO R-7 MINIMUM PER WSEC C403.2.8.1. 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2015 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2015 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2015 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2015 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. BAS TO MONITOR FIRE ALARM CONTROL PANEL AND SHUT DOWN ALL FAN TERMINAL UNITS DURING ANY BUILDING FIRE ALARM EVENT, IN ACCORDANCE WITH IMC 606.2.2. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18". 12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC), COMMERCIAL PROVISIONS AND SECTION C408. 17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 18. SHAFT WALLS CONSTRUCTED TO SUPPORT AIR MOVEMENT FOR RETURN AIR SYSTEMS AND STAIR & ELEVATOR PRESSSURIZATION SYSTEMS SHALL BE CONSTRUCTED TO THE FOLLOWING STANDARDS: A. SHAFTS (RATED FOR MAXIMIUM 2" WC) SHALL BE CONSTRUCTED TO WITHSTAND 15 PSF LOADING WITH A DEFLECTION OF L/360 (UNO). B. SHAFTS SHALL BE SEALED SUBSTANTIALLY AIR -TIGHT USING THE CRITERIA FROM THE INTERNATIONAL BUILDING CODE: 1. SECTION 715.6 FIRE RESISTANT JOINT SYSTEMS IN SMOKE BARRIERS: LEAKAGE SHALL NOT EXCEED 5 CFM PER LINEAR FOOT OF JOINT AT 0.3" WC. 2. SECTION 909.5 SMOKE BARRIER CONSTRUCTION FOR INTERIOR EXIT STAIRWAYS AND EXIT PASSAGEWAYS: MAXIMUM ALLOWABLE LEAKAGE AREA PER SHAFT SHALL NOT EXCEED (0.00035 SF/SF) C. STAIR AND ELEVATOR PRESSURIZATION SHAFTS SHALL BE PRESSURE TESTED DURING COMMISIONING. CONTRACTOR SHALL MAKE MODIFCATIONS TO INSTALLATION UNTIL SHAFT IS IN COMPLIANCE. 19. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500D): MOTORIZED DAMPERS: 4 CFM/S.F. GRAVITY DAMPERS: 20CFM/S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC, COMMERCIAL PROVISIONS, SECTION C403.2.4.3 EXCEPT AS ALLOWED BY WSEC. GAL DECRIP TITLE PROJECT ENGINEER REVIEWING ENGINEER ACCOUNT MANAGER CONSTRUCTION MANAGER GENL SUPT GENL PROJ MANAGER NAME . JARED SHEEKS BEN GEZON STEVE FLINK JOE TILSON CONTACT LIST' COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER ZCOLO PHONE NUMBER 206-768-3806 206-768-4030 253-680-3172 EMAIL JARED.SHEEKS@MACMILLER.COM BEN.GEZON@MACMILLER.COM STEVE. FLI NK@MACM ILLER.COM JOE.TILSON@ZAYO.COM 11ING SHEET INDEX NAME TITLE NAME TITLE M-001 DEMOLITION PLAN - PIPING M-101 ENLARGED EQUIPMENT YARD PLAN - PIPING M-102 GROUND LEVEL PLAN - SOUTH - PIPING M-103 GROUND LEVEL PLAN - NORTH - PIPING M-301 ELEVATIONS - PIPING M-401 DIAGRAMS - PIPING M-402 DEMOLITION DIAGRAMS - PIPING M-601 SCHEDULES - PIPING M-602 SCHEDULES - PIPING M-603 SITE PLAN 1117%, 001C ISSUED FOR PERMIT no.I date 0 12/22/16 by JS ckd 1 description BG ISSUED FOR PERMIT MacDonald -Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS9BORU designed J SHEEKS detailed J SHEEKS checked B GEZON a Zayo Group Company REVIEWED FOR CODE COMPI_iAN ZAYO GROUP, L C� C APPROVED zCOLO -TUKWILA F' ILI� 0 2011 3311 S 120TH P1 TUKWILA, WA 98168 City or Tukwila King County r ul i'�II\IG DMSll CHILLER UPGRADE PROJECT SCHEDULES - HVAC drawing rev. M-601 2 of sheets PIPING LEGEND SYMBOL DESCRIPTION ABBREVIATION GV GLV BV SYMBOL DESCRIPTION ABBREVIATION N IA 1:04 GATE VALVE GLOBE VALVE BALL VALVE - FULL PORTED A ® RI TV SOLENOID VALVE GAS COCK CIRCUIT SETTER VALVE SV GC CS N SILENT CHECK VALVE CV Q® HORIZONTAL EXPANSION TANK HET -e-i BUTTERFLY VALVE BFV 6 c=1 VERTICAL EXPANSION TANK VET 0-1 BUTTERFLY VALVE W/ MEMORY STOP BFVM 'a ® AIR SEPARATOR AIR SEP kfvvvy FLEXIBLE CONNECTION 1-6-1 =3 AIR PURGER AP RPBP UNION STRN CID KEA END SUCTION CENTRIFUGAL PUMP VERTICAL IN-LINE CENTRIFUGAL PUMP SUCTION DIFFUSER ES PUMP VI PUMP SUC DIFF • urn REDUCED PRESSURE BACKFLOW PREVENTER - il UNION STRAINER -� PSI PRESSURE RELIEF VALVE RV Q TEMERATURE GAUGE TG 06� vs, PRESSURE REDUCING VALVE PRV COMPRESSED AIR A PRESSURE / TEMPERATURE TAP BULB WELL P&T BW C CONDENSATE PIPING IT CHWS CHILLED WATER SUPPLY PIPING Y MANUAL AIR VENT MAV AV PG - CHWR - - CHILLED WATER RETURN PIPING CONDENSER WATER SUPPPLY PIPING 4 Q "-* PSI AUTOMATIC AIR VENT PRESSURE GAUGE CWS - CONDENSER WATER RETURN PIPING - -CWR- 1 X7-1CP. THERMOMETER THERM G GAS PIPING Dal, BALL VALVE W/ 3/4" HOSE ADAPTOR BV W/ HA REFRIGERANT LIQUID LINE L D CONCENTRIC REDUCER CR ER LINE S REFRIGERANT SUCTION C) ECCENTRIC REDUCER HEATING WATER SUPPLY PIPING HWS p% ® TWO-WAY CONTROL VAVLE 2WAY - - - HWR - - - HEATING WATER RETURN PIPING IAI ® THREE-WAY CONTROL VALVE 3WAY ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD-MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE-UP AIR NOMINAL OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START/STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2015 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2015 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2015 WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS - DUCT WRAP, WHERE INDICATED, SHALL BE 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER. - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM. - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT. - SUPPLY DUCT WHICH CONVEYS SUPPLY AIR AT TEMPERATURES LESS THAN 55 DEG F OR GREATER THAN 105 DEG F WHEN LOCATED IN CONDITIONED SPACE SHALL BE INSULATED WITH A MINIMUM OF R-3.3 , WHEN LOCATED IN UNCONDITIONED SPACE R-6 AND WHEN LOCATED OUTSIDE THE BUILDING R-8 (CLIMATE ZONE 4) OR R-12 (CLIMATE ZONE 5) PER WSEC C403.2.8.2. - OUTSIDE AIR DUCT INSULATION SHALL MATCH BUILDING ENVELOPE INSULATION VALUES UNLESS SERVING INDIVIDUAL SUPPLY AIR UNITS WITH LESS THAN 2800 CFM OF TOTAL SUPPLY AIR CAPACITY, PROVIDED THESE ARE INSULATED TO R-7 MINIMUM PER WSEC C403.2.8.1. 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2015 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2015 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2015 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2015 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. BAS TO MONITOR FIRE ALARM CONTROL PANEL AND SHUT DOWN ALL FAN TERMINAL UNITS DURING ANY BUILDING FIRE ALARM EVENT, IN ACCORDANCE WITH IMC 606.2.2. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18". 12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC), COMMERCIAL PROVISIONS AND SECTION C408. 17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 18. SHAFT WALLS CONSTRUCTED TO SUPPORT AIR MOVEMENT FOR RETURN AIR SYSTEMS AND STAIR & ELEVATOR PRESSSURIZATION SYSTEMS SHALL BE CONSTRUCTED TO THE FOLLOWING STANDARDS: A. SHAFTS (RATED FOR MAXIMIUM 2" WC) SHALL BE CONSTRUCTED TO WITHSTAND 15 PSF LOADING WITH A DEFLECTION OF L/360 (UNO). B. SHAFTS SHALL BE SEALED SUBSTANTIALLY AIR -TIGHT USING THE CRITERIA FROM THE INTERNATIONAL BUILDING CODE: 1. SECTION 715.6 FIRE RESISTANT JOINT SYSTEMS IN SMOKE BARRIERS: LEAKAGE SHALL NOT EXCEED 5 CFM PER LINEAR FOOT OF JOINT AT 0.3" WC. 2. SECTION 909.5 SMOKE BARRIER CONSTRUCTION FOR INTERIOR EXIT STAIRWAYS AND EXIT PASSAGEWAYS: MAXIMUM ALLOWABLE LEAKAGE AREA PER SHAFT SHALL NOT EXCEED (0.00035 SF/SF) C. STAIR AND ELEVATOR PRESSURIZATION SHAFTS SHALL BE PRESSURE TESTED DURING COMMISIONING. CONTRACTOR SHALL MAKE MODIFCATIONS TO INSTALLATION UNTIL SHAFT IS IN COMPLIANCE. 19. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500D): MOTORIZED DAMPERS: 4 CFM/S.F. GRAVITY DAMPERS: 20CFM/S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC, COMMERCIAL PROVISIONS, SECTION C403.2.4.3 EXCEPT AS ALLOWED BY WSEC. GAL DECRIP TITLE PROJECT ENGINEER REVIEWING ENGINEER ACCOUNT MANAGER CONSTRUCTION MANAGER GENL SUPT GENL PROJ MANAGER NAME . JARED SHEEKS BEN GEZON STEVE FLINK JOE TILSON CONTACT LIST' COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER ZCOLO PHONE NUMBER 206-768-3806 206-768-4030 253-680-3172 EMAIL JARED.SHEEKS@MACMILLER.COM BEN.GEZON@MACMILLER.COM STEVE. FLI NK@MACM ILLER.COM JOE.TILSON@ZAYO.COM 11ING SHEET INDEX NAME TITLE NAME TITLE M-001 DEMOLITION PLAN - PIPING M-101 ENLARGED EQUIPMENT YARD PLAN - PIPING M-102 GROUND LEVEL PLAN - SOUTH - PIPING M-103 GROUND LEVEL PLAN - NORTH - PIPING M-301 ELEVATIONS - PIPING M-401 DIAGRAMS - PIPING M-402 DEMOLITION DIAGRAMS - PIPING M-601 SCHEDULES - PIPING M-602 SCHEDULES - PIPING M-603 SITE PLAN 1117%, 001C ISSUED FOR PERMIT no.I date 0 12/22/16 by JS ckd 1 description BG ISSUED FOR PERMIT MacDonald -Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS9BORU designed J SHEEKS detailed J SHEEKS checked B GEZON a Zayo Group Company REVIEWED FOR CODE COMPI_iAN ZAYO GROUP, L C� C APPROVED zCOLO -TUKWILA F' ILI� 0 2011 3311 S 120TH P1 TUKWILA, WA 98168 City or Tukwila King County r ul i'�II\IG DMSll CHILLER UPGRADE PROJECT SCHEDULES - HVAC drawing rev. M-601 2 of sheets Millimeters Scale For Microfilming 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0 z z cL 2 0 0 0 z w w z C7 z w w z z 0 U 025 z Cr; N 0 1- = a 0 0 CH -01,02,03,04: AIR-COOLED CHILLER SERVES: DATA CENTER SCHEDULE: AVAILABLE CONTINUOUSLY T CHILLED WATER TEMPERATURE SETPOINT: 48°F FIRE ALARM CONNECTION: NO FIRE ALARM SEQUENCE: UNIT ACTIVE DURING FIRE ALARM SEQUENCE (VARIABLE VOLUME CHILLED WATER W/ WATERSIDE ECONOMIZER): OVERVIEW: THERE ARE (2) AIR-COOLED CHILLERS THAT SERVE THE DATA CENTER. PROVISIONS ARE MADE FOR A THIRD AND FOURTH CHILLER TO BE INSTALLED IN THE FUTURE, WITH THE FOURTH PROVIDING N+1 REDUNDANCY. THE CHILLERS ARE OPERATED IN A PARALLEL ARRANGEMENT, WITH A MAXIMUM OF 3 OPERATING AT ANY GIVEN TIME. CHILLER STAGING: THE LEAD CHILLER IS ENABLED TO RUN CONTINUOUSLY. THE CHILLER PACKAGED CONTROLS DETERMINE THE LOADING, ECONOMIZER OPERATION, AND SAFETY FUNCTIONS. THE CHILLED WATER SHALL NOT USE A TEMPERATURE RESET SCHEDULE. AS CHILLER LOAD REACHES 85% OR GREATER FOR 10 MINUTES THE CONTROL SYSTEM SHALL START EACH ADDITIONAL CHILLER, ONE AT A TIME WITH A 30 MINUTE INTERSTAGE DELAY, UNTIL ALL 3 CHILLERS ARE OPERATING. WHEN AN ADDITIONAL CHILLER IS ENABLED, THE OPERATING CHILLER'S CAPACITY IS LIMITED TO 60%. ONCE THE OPERATING CHILLER(S) HAVE MAINTAINED THE 60% LOADING FOR 2 MINUTES, THEN THE ISOLATION VALVE ON THE STARTING CHILLER IS OPENED. ONCE THE VALVE HAS FULLY OPENED, THE CHILLER IS STARTED. WHEN THE STARTING CHILLER HAS REACHED 35% CAPACITY, THE LIMITED CHILLER(S) ARE ALLOWED TO RESUME NORMAL OPERATION. WHEN MULTIPLE CHILLERS ARE RUNNING AND THE LOAD IS REDUCED TO LESS THAN 40%, FOR 10 MINUTES, THE LAG CHILLERS SHALL BE TURNED OFF ONE AT A TIME. WHEN A CHILLER IS TAKEN OFFLINE, THE PACKAGED CONTROL SYSTEM SHALL SHUT OFF THE MECHANICAL COOLING. THE BAS SHALL HOLD THE CHILLED WATER VALVE OPEN FOR 5 MINUTES. IF ONLY THE LEAD CHILLER IS RUNNING, THE PACKAGED CONTROLS MAY SHUT OFF COOLING, BUT THE CHILLED WATER VALVE SHOULD REMAIN OPEN. THE LEAD CHILLER SHALL BE ROTATED ONCE PER MONTH TO EQUALIZE RUN TIME. SHOULD ANY CHILLER FAIL, BE OFFLINE FOR MAINTENANCE, OR IN A FAULT CONDITION, THE BAS SHALL SKIP THE CHILLER IN THE STARTUP ROTATION AND USE THE NEXT AVAILABLE CHILLER. ECONOMIZER: THE FOLLOWING ECONOMIZER SEQUENCE IS CONTROLLED BY THE CHILLER'S PACKAGED CONTROL SYSTEM: • THE CONTROLLER WILL ACCEPT THE COOLING ENABLE SIGNAL FROM THE BUILDING BAS. ONCE IT RECEIVES THE ENABLE SIGNAL, IT WILL ENABLE THE CHILLER AND ALLOW THE ECONOMIZER TO FUNCTION IF CONDITIONS HAVE BEEN MET TO ECONOMIZE. • ECONOMIZER CHILLED WATER SETPOINT SHALL MATCH THE CHILLER'S ACTIVE CHILLED WATER SETPOINT. NORMAL CHILLER OPERATION (FULL MECHANICAL COOLING) MODE (NO ECONOMIZER, OAT > 55°F) • DIVERTING VALVE IS BYPASSING ECONOMIZER • THE CHILLER'S CH530 IS IN FULL CONTROL OF ALL UNIT FUNCTIONS DURING MECHANICAL COOLING NORMAL CHILLER OPERATION WITH PARTIAL ECONOMIZING (55°F z OAT > 35°F) • ONCE THE OUTSIDE AIR TEMPERATURE (OAT) IS 3°F LESS THAN THE ECONOMIZER ENTERING FLUID (EWT), THE DIVERTING VALVE IS OPENED TO ALLOW WATER TO PASS THROUGH THE ECONOMIZER. THE WATER PASSES THROUGH THE ECONOMIZER COILS FIRST AND THEN ENTERS THE CHILLER. ANY COOLING THAT THE ECONOMIZER PROVIDES WILL LOWER THE LOAD THAT THE CHILLER SEES. • THERE ISA 2° DEADBAND ON THE DIVERTING VALVE CONTROL. IF THE OAT RISES TO 1°F LESS THAN EWT, THE DIVERTING VALVE WILL CLOSE. • THE CONDENSER FANS ARE CONTROLLED BY THE CHILLER'S C14530 WHENEVER A CIRCUIT IS IN MECHANICAL COOLING MODE, AND ARE STAGED ON BY THE UC400 WHEN A CIRCUIT IS IN WSE MODE ONLY. NORMAL CHILLER OPERATION WITH PARTIAL ECONOMIZING ON ONE CIRCUIT AND FULL ECONOMIZER OPERATION ON THE OTHER CIRCUIT (35° F > OAT z 25.6°F) • WHEN THE OAT DROPS BELOW 35°F, THE CHILLER WILL BE ABLE TO MEET THE LOAD REQUIREMENTS OF 311.7 TONS OF COOLING WITH ONE CIRCUIT PROVIDING NORMAL COOLING AND THE OTHER CIRCUIT RUNNING ON ECONOMIZER MODE. • THE UC400 WILL LOCK OUT THE LEAD CIRCUIT WHEN THE OAT FALLS TO 35°. THE LOCKOUT WILL BE REMOVED WHEN THE OAT RISES TO 37°F (2° DEADBAND). • THE UC400 WILL CONTROL THE FANS ON THE LEAD CIRCUIT AND TRY TO REACH THE CHILLED WATER SETPOINT ON THE EVAPORATOR LWT. • DURING THIS MODE, THE CONDENSING FANS ON THE LEAD CIRCUIT WILL NOT BE ABLE TO REACH THE CHILLED WATER SETPOINT SO THEY WILL BE OPERATING AT 100%, GETTING MAXIMUM COOLING THE AMBIENT TEMPERATURE WILL PROVIDE. • THE LAG CIRCUIT'S CONDENSER FANS WILL CONTINUE TO BE CONTROLLED BY THE CHILLER'S CH530. • THE LAG CIRCUIT WILL STILL BE PROVIDING MECHANICAL COOLING TO MEET THE LWT SETPOINT. • THERE IS A LOCKOUT OVERRIDE. IF EVAPORATOR LWT RISES TO 2°F ABOVE SETPOINT, THE LOCKOUT ON THE LEAD CIRCUIT WILL BE REMOVED AND THE LEAD CIRCUIT WILL BEGIN MECHANICAL COOLING. ECONOMIZER ONLY OPERATION MODE (OAT 5 25.6°F) • DIVERTING VALVE IS ALLOWING WATER TO PASS THROUGH THE ECONOMIZER • CHILLER CIRCUITS 1 AND 2 WILL BE LOCKED OUT BY THE UC400 • RETURN AND LEAVING WATER TEMPERATURES ARE MONITORED, AND THE UC400 WILL STAGE THE CONDENSER FANS TO MAINTAIN THE ECONOMIZER CHILLED WATER SETPOINT • CONDENSER FANS WILL SHUT OFF WHEN THE LEAVING WATER HAS FALLEN 2 DEGREES BELOW THE ECONOMIZER CHILLED WATER SETPOINT. • WHEN THE LEAVING WATER TEMP HAS RISEN 2 DEGREES ABOVE THE ECONOMIZER CHILLED WATER SETPOINT THE CONDENSER FANS WILL BE RE -ENABLED TRYING TO MAINTAIN THE CHILLED WATER SETPOINT ONCE AGAIN. • THERE IS A 2°F DEADBAND ON LOCKING OUT CIRCUITS 1 AND 2. WHEN THE OAT REACHES 28°F THE LAG CIRCUIT WILL NOT BE LOCKED OUT AND WILL RESUME NORMAL COOLING OPERATION. • THERE IS A LOCKOUT OVERRIDE. IF EVAPORATOR LWT RISES TO 2°F ABOVE SETPOINT FOR 10 MINUTES, THE LOCKOUT ON THE LEAD CIRCUIT WILL BE REMOVED AND WILL BEGIN MECHANICAL COOLING. LEAD / LAG CIRCUITS • THE CIRCUITS WILL ALTERNATE BETWEEN LEAD AND LAG CIRCUITS ONCE A WEEK TO PROVIDE APPROXIMATE EQUAL RUN TIME. THE CIRCUITS ARE SET TO ALTERNATE EVERY MONDAY MORNING. SAFETY CYCLE • ALL STANDARD UNIT SAFETY CIRCUITS ARE IN EFFECT. • ANY TIME FLOW IS NOT PROVEN, THE ECONOMIZER WILL NOT BE ALLOWED TO OPERATE P-01,02,03,04: CHILLED WATER PUMPS SERVES: DATA CENTER SCHEDULE: AVAILABLE CONTINUOUSLY DIFFERENTIAL PRESSURE SETPOINT: DETERMINED DURING BALANCING TO MAINTAIN FLOW AT CRAH-7 FIRE ALARM CONNECTION: NO FIRE ALARM SEQUENCE: OPERATES DURING FIRE ALARM SEQUENCE (VARIABLE VOLUME PUMPING): OVERVIEW: THERE ARE (3) CHILLED WATER PUMPS THAT SERVE THE DATA CENTER, WITH A FOURTH PROVIDING N+1 REDUNDANCY. THE PUMPS ARE OPERATED IN A PARALLEL ARRANGEMENT, WITH A MAXIMUM OF 3 OPERATING AT ANY GIVEN TIME. PUMP STAGING: THE LEAD PUMP IS ENABLED TO RUN CONTINUOUSLY. THE PUMP SHALL MODULATE ITS SPEED TO MAINTAIN THE DIFFERENTIAL PRESSURE AT THE REMOTE SENSOR. WHEN PUMP SPEED EXCEEDS 70% OF MAXIMUM (42 HZ) FOR 5 MINUTES, THE BAS SHALL ENABLE A SECOND PUMP. THE TWO PUMPS SHALL CONTROL TO THE SAME SIGNAL. WHEN THEIR SPEED EXCEEDS 50 HZ FOR 5 MINUTES, THE BAS SHALL ENABLE A THIRD PUMP. WHEN PUMP SPEED REDUCES BELOW 48 HZ FOR 5 MINUTES, THE BAS SHALL DISABLE THE 3RD PUMP. WHEN PUMP SPEED DROPS BELOW 40 HZ FOR 5 MINUTES, THE BAS SHALL DISABLE THE 2ND PUMP. THE LEAD PUMP SHALL BE ROTATED ONCE PER MONTH TO EQUALIZE RUN TIME. SHOULD ANY PUMP FAIL, BE OFFLINE FOR MAINTENANCE, OR IN A FAULT CONDITION, THE BAS SHALL SKIP THAT PUMP IN THE STARTUP ROTATION AND USE THE NEXT AVAILABLE PUMP. FAN COIL SCHEDULE UNIT NO. AREA SERVED TRANE MODEL NO. BLOWER CFM MIN OSA CFM ESP (IN WG) HP ELEC VOLT/PH FLA/MCA WEIGHT (LBS) NOTES FC -M01 ELECTRICAL ROOM UCCAAO8C 4000 0 0.75 3 460/3 5.02/6.22 660 EXIST,1-7 531 531 531 33345 NEW 1-3 33345 FUTURE CH -04 TRANE RTAE-300E 300 780 33345 FUTURE NOTES: 1. POWER WIRING AND DISCONNECT BY ELECTRICAL. 2. PROVIDED WITH THE FOLLOWING: - INTEGRAL WATERSIDE ECONOMIZER PACKAGE WITH 3 -WAY CONTROL VALVE AND CONTROLLER. - STEALTH INVISISOUND PACKAGE - HFC -134A REFRIGERANT - 2 PASS EVAPORATOR - FACTORY FLOW SWITCH - FACTORY INSULATION - WIDE AMBIENT (0 TO 125°F) - ADAPTIVE FREQUENCY DRIVE - DUAL CIRCUIT ROTARY SCREW COMPRESSORS - 65K HIGH AMP SHORT CIRCUIT RATING - LINE REACTORS 3. INSTALL ON FACTORY PROVIDED NEOPRENE ISOLATIONS ON NEW CONCRETE LEVELING PADS (PROVIDED BY OTHERS). Y 13.39 460/3 UNIT NO. AREA SERVED FIRST CO. MODEL NO. COOLING COIL TOTAL MBH SENS MBH EAT (DBIWB) LAT (DBIWB) EWT/LWT (DEG F) CONTROL VALVE FLOW GPM FLOW DP (FT) CHWS/R SIZE FC -M01 ELECTRICAL ROOM UCCAAO8C 121.4 121.4 80/60 52.2/48.7 45/55 3 -WAY 24.2 2.9 1-1/2" 495.3 100 14.6 Y Y 13.39 460/3 66.3 2,900 NEW1-5 CRAH-9 LIEBERT CW181DC NOTES: 1. RIGHT HAND SIDE CONTROL AND COIL CONNECTIONS 2. DISCONNECT BY ELECTRICAL CONTRACTOR. 3. PROVIDE RETURN AIR SMOKE DETECTOR. TIE INTO FIRE ALARM SYSTEM BY OTHERS. 4. 3 -WAY CONTROL VALVE AND ACTUATOR BY MM (Cv = 21). WIRING AND INTEGRATION INTO EXISTING CONTROLS SYSTEM BY CONTROLS CONTRACTOR. 5. FACTORY INSTALLED OPTIONS: STAINLESS STEEL DRAIN PAN, 2" MERV 8 FILTER RACK, HORIZONTAL FRONT TOP DISCHARGE CONFIGURATION, CONTROL INTERFACE, 2" DOUBLE WALL CONSTRUCTION. 6. FIELD ROUTE CONDENSATE TO CLOSEST FLOOR DRAIN IN UPS ROOM BELOW. 7. INSTALL DRIP PAN BELOW FAN COIL. LEAK DETECTION AND ALARMING BY CONTROLS CONTRACTOR. AIR COOLED CHILLER SCHEDULE UNIT NO. CH -01 MFG & MODEL NO. TRANE RTAE-300E NOM TONS 300 GPM 780 CHILLED DP FT 49.2 9 WATER EWT °F 58 LWT °F ... 48 GLY% _... ._.. 25 EER! IPLV ._.. 11.9/20480/ ELECTRICAL VOLT/PH 3 .__._....531......._ MCA WT LBS NOTES 33345 _..., _. ...._. NEW 1-3._.. _..... CH -02 CH -03 TRANE RTAE-300E TRANE RTAE-300E 300 300 780 780 49.2 49.2 49.2 58 58 58 48 48 48 25 25 25 11.9/20 11.9/20 11.9/20 480/3 480/3 480/3 531 531 531 33345 NEW 1-3 33345 FUTURE CH -04 TRANE RTAE-300E 300 780 33345 FUTURE NOTES: 1. POWER WIRING AND DISCONNECT BY ELECTRICAL. 2. PROVIDED WITH THE FOLLOWING: - INTEGRAL WATERSIDE ECONOMIZER PACKAGE WITH 3 -WAY CONTROL VALVE AND CONTROLLER. - STEALTH INVISISOUND PACKAGE - HFC -134A REFRIGERANT - 2 PASS EVAPORATOR - FACTORY FLOW SWITCH - FACTORY INSULATION - WIDE AMBIENT (0 TO 125°F) - ADAPTIVE FREQUENCY DRIVE - DUAL CIRCUIT ROTARY SCREW COMPRESSORS - 65K HIGH AMP SHORT CIRCUIT RATING - LINE REACTORS 3. INSTALL ON FACTORY PROVIDED NEOPRENE ISOLATIONS ON NEW CONCRETE LEVELING PADS (PROVIDED BY OTHERS). no.I date 0 12/22/16 by JS ckd description BG ISSUED FOR PERMIT PUMP SCHEDULE UNIT NO. P-01 UNIT SERVED CHILLERS MFG & MODEL NO. B&G E-1510-4GC TYPE GPM DP FT IMP DIA IN HP RPM END SUC. 780 175 13.5 50 1770 PUMP VOLT/PH EFF. 460/3 81.7% WT LBS 1040 NOTES REPLACE 1-5 P-02 CHILLERS B&G E-1510-4GC END SUC. 780 175 13.5 P-03 CHILLERS B&G E-1510-4GC END SUC. 780 175 13.5 P-04 CHILLERS B&G E-1510-4GC END SUC. 780 175 13.5 50 50 50 1770 460/3 81.7% 1040 REPLACE 1-5 1770 460/3 81.7% 1040 NEW 1-5 1770 460/3 81.7% 1040 FUTURE NOTES: 1. ELECTRICAL CONTRACTOR TO PROVIDE POWER WIRING AND DISCONNECT 2. WITH FLANGES & P&T TAPS AT EACH FLANGE 3. 175 PSI MAX. WORKING PRESSURE 4. WITH VFD, PROVIDED BY MECH AND INSTALLED BY ELEC. ABB ACH550 OR APPROVED. 5. INTEGRATE INTO EXISTING CONTROLS SYSTEM BY OTHERS. SEE SEQUENCE OF OPERATION. UNIT___ NO. MFG & MODEL NO. CHILLED SUPPLY FAN WATER COMPUTER ROOM AC SCHEDULE REHEAT WT LBS NOTES CHILLED WATER COIL HUMID LBS/HR SCOP ELECTRICAL CFM ESP BHP TOT MBH SENS MBH GPM DP FT VOLT/PH FLA CRAH-6 LIEBERT CW181 DC 21,600 0.2 12.5 545.5 495.3 100 14.6 Y Y 13.39 460/3 66.3 2,900 EXIST 1-5 CRAH-7 LIEBERT CW181 DC 21,600 0.2 12.5 545.5 495.3 100 14.6 Y Y 13.39 460/3 66.3 2,900 EXIST 1-5 CRAH-8 LIEBERTCW181DC 21,600 0.2 12.5 545.5 495.3 100 14.6 Y Y 13.39 460/3 66.3 2,900 NEW1-5 CRAH-9 LIEBERT CW181DC 21,600 0.2 12.5 545.5 495.3 100 14.6 Y Y 13.39 460/3 66.3 2,900 NEW 1-5 NOTES: 1. CAPACITIES BASED ON 45F EWT/57F LWT CHILLED WATER WITH 20% PROPYLENE GLYCOL, 75DF DB/61.1 DFWB ENTERING AIR 2. ACCESSORIES: FILTERS - 4" THICK 30% ASHRAE STANDARD 52-76, 18" FILTER PLENUM, STANDARD INFRARED HUMIDIFIER, ELECTRIC REHEAT, FIRE STATE SHUTDOWN, SMOKE DETECTOR, LOCKING DISCONNECT SWITCH, DRY CONTACTS FOR REMOTE MONITORING OF ALARM, MICROPROCESSOR BASED CONTROLS, QTY (2) 2 -WAY CHILLED WATER VALVE, DOWNFLOW CONFIGURATION WITH 12" SEISMIC FLOOR STAND, INTERNAL CONDENSATE PUMP, (2) LT410 POINT LEAK DETECTION SENSORS, IS -UNITY -DP CARD, 65K SCCR. 3. PROVIDED WITH 3 DIRECT DRIVE EC PLUG FANS INSIDE THE UNIT. 4. CONNECT TO EXISTING CENTRAL CHILLED WATER SYSTEM. 5. PROVIDED BY CUSTOMER, INSTALLED BY MECHANICAL. VARIABLE FREQUENCY DRIVE SCHEDULE UNIT NO. SERVES LOCATION MFG & MODEL NO. HP VOLT/PH WT LBS NOTES VFD-01 P-01 MECHANICAL ROOM ABB ACH550 50 460/3 60 NEW, 1,2,3,4 VFD-02 P-02 VFD-03 P-03 MECHANICAL ROOM MECHANICAL ROOM ABB ACH551 50 460/3 60 ABB ACH552 50 460/3 60 NEW, 1,2,3,4 NEW, 1,2,3,4 VFD-04 P-04 MECHANICAL ROOM ABB ACH552 50 460/3 60 FUTURE, 1,2,3,4 NOTES: 1. VFD PROVIDED BY MECHANICAL, MOUNTED AND WIRED BY ELECTRICAL. LOCATE TO INSURE ADEQUATE VENTILATION. 2. PROVIDE FACTORY INTEGRATED DISCONNECT SWITCH. 3. PROVIDE NEMA 12 ENCLOSURE, WITH ADEQUATE COOLING AS REQUIRED TO INSURE NORMAL RELIABLE INDOOR OPERATION. 4. ELECTRICAL REQUIREMENTS AND COORDINATION: - ELEC TO POWER WIRE FAN MOTOR THROUGH VARIABLE FEQUENCY DRIVE (VFD FURNISHED BY MECHANICAL, MOUNTED AND WIRED BY ELECTRICAL) - LINE AND LOAD WIRING TO BE RUN IN SEPARATE CONDUITS - REFER TO MANUFACTURER INFORMATION ON MAXIMUM DISTANCE FROM EQUIPMENT MacDonald -Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU Ht'7 00l5- ISSUED FOR PERMIT RECEIVED CITY OF TUKWILA JAN 262017 PERMIT CENTER date 12-16-16 designed J SHEEKS detailed J SHEEKS checked B GEZON 2C010 a Zayo Group Company ZAYO GROUP, LLI*VIEWED FOR zCOLO - TUKWILA ROVED CE 3311 S 120TH PL TUKWILA, WA 9':16EFEB 01 2611 King County CHILLER UPGRADE DIVISIOP , SCHEDULES - H AC project 73166503-00 contract CONTRACT drawing rev. M-602 2 sheet file of sheets