Loading...
HomeMy WebLinkAboutPermit M17-0016 - EMERALD CITY GRAPHICS - DUCTLESS SPLIT SYSTEMEMERALD CITY GRAPHICS 1011 ANDOVER PARK E M17-0016 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049019 262304-9019 2623049019 Permit Number: M17-0016 1011 ANDOVER PARK E EMERALD CITY GRAPHICS Issue Date: 2/8/2017 Permit Expires On: 8/7/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: M3 PROPERTIES LLC 901 POWELL AVE SW #101 C/O JSH PROPERTIES INC, RENTON, WA, 98057 JESSE CHUTICH 3202 C ST NE , AUBURN, WA, 98002 COMFORT MECHANICAL INC 3202 C ST NE , AUBURN, WA, 98002 COMFOM1015LA Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: 4/25/2018 DESCRIPTION OF WORK: INSTALL (1) DUCTLESS SPLIT SYSTEM TO SERVE SERVER ROOM Valuation of Work: $5,075.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $285.78 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Date: (4' _ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to conditions attached to this permit. Signature: Print Name: 3eSs� <--74 'C/ Date: 274/7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 2: ***MECHANICAL PERMIT CONDITIONS*** 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. MIS - On Project No. t/1Date Application Accepted: n \ `j Date Application Expires: " 1 i (For office use on y) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: / 011 A Ido v er Rt.r JC King Co Assessor's Tax No.: Z'Z 3© 51 —10/1 1 Tenant Name: 1-, Iy el -40 C 14 y j r 4p1✓}i" C PROPERTY OWNER Name: Jesse Chutich Address: 3202 C St NE Name: ^^ r r oPe,C'4r e S� -1 Phone: (425) 251-9840 Fax: Email: jesse@comfortmech.com Address: o o l Andover F r f 1 P City: TK k w ( State: Zip: CONTACT PERSON — person receiving all project communication Name: Jesse Chutich Address: 3202 C St NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Email: jesse@comfortmech.com Suite Number: Floor: New Tenant: ❑ Yes MECHANICAL CONTRACTOR INFORMATION Company Name: Comfort Mechanical Inc. Address: 3202 C St NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Contr Reg No.: COMFOMI015LA Exp Date: 04/25/2018 Tukwila Business License No.: BUS -0993365 Valuation of project (contractor's bid price): $ S O7 S Describe the scope of work in detail: -y151-fit (i) dh►vilesc spl;1 S yOeM' 4-o Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Serve Server rOor-- • Fuel Type: Electric Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Noise: Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfin Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) ' 65 dB(A) :4 n» Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu . . Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are. based on fi-om where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night.in a residential Ione it inay not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) ' 65 dB(A) Industrial 60 dB(A) 50 dB(A) - 65 dB(A) ' ` ' 70 dB(A) • *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.. 1- A- A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (cine nt edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND IAM AUTHORIZED TO•APPLY FOR THIS PERMIT. BUILDING ORJ�THORIZED AGENT: Signature: (l// Print Name: Tes. e Date: /,/ o// 7 Day Telephone: CPS— S— 2- —( q S r0 Mailing Address: ZO - C. A/1 A t'✓A• a goo City H:\Applications\Form-Applications On Line \2016 Applications \Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $285.78 M17-0016 Address: 1011 ANDOVER PARK E Apn: 2623049019 262304-9019 $285.78 Credit Card Fee $8.32 Credit Card Fee I R000.369.908.00.00 0.00 $8.32 MECHANICAL $266.79 PERMIT FEE R000.322.100.00.00 0.00 $180.28 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.102.00.00 0.00 $53.36 TECHNOLOGY FEE $10.67 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10653 R000.322.900.04.00 0.00 $10.67 $285.78 Date Paid: Monday, January 30, 2017 Paid By: JESSE CHUTICH Pay Method: CREDIT CARD 710374 Printed: Monday, January 30, 2017 3:47 PM 1 of 1 CRSYS1EMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit Th!7- 0016 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 9818 (20 ) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ,&4612A -a. ari 9d / cS Type of Inspection: Al ai-I EI AJ 1 cA Z- 7'"//KI1-- Address: /O/ I /- outol✓�- e PAive Date Called: Special Instructions: Date Way/ ,ll 7 j_16 p. . Requeste : Phone No: i7' Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: PAwt Date: ,-A,0// f f REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. High Wall Residential Heat Pump System Indoor Model: 40MAQB12B--3 Outdoor Model: 38MAQB12---3 Job Data: Submittal Data Buyer. Buyer P.O. #: Unit Number. Location: Carrie turn to the experts J Model Number. Carrier #: Performance Data Certified By: Date: 'A 1 Puron. Performance' SERIES HIGHWALL STANDARD FEATURES • Variable Speed (Inverter) • Modes: Cool, Heat, Dry, Fan, Auto • Auto louver mode • Turbo mode • Sleep mode • Dehumidification mode • Follow me • 46.F Heating Mode (Heating Setback) • Quiet operation CONTROL FEATURES • Wireless remote control (standard) • Wired remote control (optional) (Unless otherwise indicated, data applies to both indoor and outdoor models) SYSTEM SIZE REFRIGERANT R -410A 12 ELECTRICAL System Voltage 208/230-1-60 Indoor Unit Wired from Outdoor Wires between Indoor and Outdoor 4 MCA 15 MOCP 15 CONTROLS Wireless Remote Standard Wired Control Optional REFRIGERANT LINES Total Piping Length (ft) 82 Vertical Lift (ft) 32 1,200 Suction Line Size (in) 1/2 56 Liquid Line Size (in) 1/4 AMBIENT OPERATING RANGE Cooling DB Min - Max (F) 4-122 Heating DB min- Max (F) 4-86 UNIT WEIGHT - GrossfNet Indoor unit (lbs) 24.6/19.1 Outdoor unit (lbs) 88.1/82.4 PERFORMANCE Rated Capacity Cooling (Btuh) 12,000 Range Cooling (Btuh) 4,000-13,000 Rated Capacity Heating (Btuh) 12,000 Range Heating (Btuh) 5,000-13,500 SEER/EER 21.5/13 HSPF 10.0 OUTDOOR Airflow (ft) Sound Pressure (dBA) INDOOR Airflow Lowest to Highest (cfm) 210/300/360/380 Air throw (ft) 23 Sound Pressure Lowest to Highest Cooling Mode (dBA) 27/34/42 Sound Pressure Lowest to Highest Heating Mode (dBA) 27/34/41 Accessories: ❑Wired Control Convertible - Fahrenheit / Celsius ❑ Insulated 25' Line Set - 1/2" x 1/4" Copyright2014 Carrier Corp. S 7310 W. Monis St S Indianapolis, IN 46231 Edfion Date: 11/17 0 Condensate Pump 208/230V Catalog No: SUB38-40MA-12-01 Manufacturer reserves the right to change, at any lime, spedfirafions and designs without notice and without obligations Replaces NEW rh.„„ OOl6 Construction View. Indoor Unit 40MAQB12B--3 Outdoor Unit 38MAQB12---3 Unit Size W in (mm) D in (mm) H in (mm) Operating Weight Ib (kg) 12K 32.8(835) 7.8(198) 11.0(280) 19.1(8.7) H 31.89(810) W B2 ..}12.6 66.6) 4.10(104.2) H in (mm) W1 in (mm) D1 in (mm) i 12K 31.8(810) 12.2(310) ali \ 21.6(549) Unit:inch(mm) D1 Unit Size W in (mm) D in (mm) H in (mm) W1 in (mm) D1 in (mm) Operating Weight Ib (kg) 12K 31.8(810) 12.2(310) 21.9(558) 21.6(549) 12.8(325) 82.4(37.4) Sus :'Un?mry Small AC P.HHl SWlldad 210!240' --.. Copyright 2014 Carrier Corp. S 7310 W. Morris SL S Indianapolis IN 46231 Edfon Dale: 11/17 Catalog No: SUB38.40MA-12-01 Manufacturer reserves the right to change, at my time, spedkaions and designs without notice and without obligations 2 Replaces NEW PERMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0016 DATE: 01/31/17 PROJECT NAME: EMERALD CITY GRAPHICS SITE ADDRESS: 1011 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ti Building Division Public Works krA Ayx 9�f Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 01/31/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 02/28/17 ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: . REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION. LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: - 12/18/2013 COMFORT MECHANICAL INC Home Espaiiol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 Al A -Z Index Help My l.&1 Workplace Rights Trades & Licensing COMFORT MECHANICAL INC Owner or tradesperson Principals JACKSON, SHIRLEY A, PRESIDENT JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA 98002 425.251-9840 KING County Business type Corporation Governing persons HERB J JACKSON SHIRLEY A JACKSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOMI015LA Effective — expiration 06/01/1999— 04/25/2018 Bond Lexon Ins Co $6,000.00 Bond account no. 9815017 Received by L&I Effective date 06/04/2012 06/01/2012 Expiration date Until Canceled Bond history Insurance Continental Western Ins Co $1,000,000.00 Policy no. CPA6015115 Received by L&I Effective date 05/25/2016 06/01/2016 Expiration date 06/01/2017 Insurance history Savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 2/8/2017 COMFORT MECHANICAL INC No savings accounts during the previous 6 )eriod. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. LSI Tax debts No LSI tax debts are recorded for thiscontractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 973,224-00 Doing business as COMFORT MECHANICAL INC Estimated workers reported Quarter 4 of Year 2016 "11 to 20 Workers" L&I account representative T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 10/16/2012 Inspection no. 316456144 Location 444 Valley Mall Parkway East Wenatchee, WA 98802 Violations Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 2/8/2017 PARCEL Parcel Number 262304-9019 2623049019 Name M3 PROPERTIES LLC Site Address 1001 ANDOVER PARK E 98188 Legal POR SE 1/4 OF SE 1/4 BEG NW COR SD SUBD TH S 88-12-32 E 30 FT TH CONTG S 88-12-32 E 360 FT TH S 01-47-28 W 21 FT TO SLY MGN OF MINKLER BLVD & TPOB TH S 88-12-32 E 486.50 FT TO WLY MGN ANDOVER PARK EAST TH S 01-47-28 W 540.90 FT TH TANGENT TO THE PRECEDING COURSE ALG ARC OF CURVE TO TGT RAD 322.62 FT C/A 21-02-23 ARC LENGTH 118.47 FT TAP OF REV CURVATURE TH TANGENT TO PRECEDING CURVE ALG ARC OF CURVE TO LFT RAD 382.62 FT C/A 01-43-06 ARC LENGTH OF 11.47 FT TH LEAVING SD WLY MGN ANDOVER PARK EAST N 88-12-32 W 474.54 FT TH FR A TANGENT THAT BEARS N 19-02-43 E ALG ARC OF CURVE TO LFT. RAD 300.16 FT & C/A 17-15-15 ARC LENGTH 90.39 FT TH TANGENT TO PRECEDING CURVE N 01-47-28 E 578.55 FT TO TPOB MINKLER BLVD Blvd - Upland Dr Midland Dr a- 0 0 A ACTT +?r Perk MTh i:tcr 4:1tvd 1011 Andover Park E Andover.Park E. :tat lines 7 4161fai:tegal use King Conn Minkler Bhc: 0 g 7 PROJECT DESCRIPTION: 1. INSTALL (1) 1 -TON DUCTLESS SPLIT SYSTEM INCLUDING ROOFTOP CONDENSING UNIT AND INDOOR AIR HANDLER T SERVE S O SERVER VER R04M: GENERAL NOTES: 1. SUCTION REFRIGERANT. PIPING TO BE INSULATED TO MEET 2015 WSEC. 2. INSTALL GFCI OUTLET WITHIN 25' OF CONDENSING UNIT. 3. CONDENSING. UNIT TO SIT ON 4X4 PRESSURE TREATED WOOD SLEEPERS. 4. PROVIDE COMMISSIONING REPORT. . covIAnne,tA✓Yoh corier7 v /1/146,40 1,1101( n2 (4) SERVER.. RACKS AND (1) MONITOR = 3,500 WATTS 3,500 WATTS X 3.412 =1.1,942 BTUS 12,000 BTU . DUCTLESS. SPLIT HVAC Equipment Schedule (New) . # . Brand . Model. ! . Ton . Total CFM . Cap: Heat _ Cap. Cool SEER _ Weight Sound(bels) Location CU -1 Carrier. 38MAQB12 1 . - VAV DUCTLESS AIR HANDLER ..21.5 82 lbs. 59 Roof - AH -1 Carrier 40MAQB12B 1 • .• _380 max 12000(max) 12000(max) . 21.5 19 lbs. 42 max Teller Line • I DOAS Is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no ■ Ventilation provided via natural ventilation per 2015 IMC In lieu of DOAS (C403.6, • and space conditioning provided by a HEVAV system per 0403.7 In lieu Ventilation Ii DOAS included in project, although not required (occupancy not office, retail, education, ■ DOAS related allowances included in project: I■ Prescriptive vertical fenestration maximum area allowance Increased to 40% per conditioned floor area in building served by DOAS. - II .Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power exceeds Shp. 5 horsepower threshold. is Project includes HVAC air distribution systems that provide heating and/or cooling if yes, provide a MECH-FANSYS-SUM form. • For one or more systems, the total fan motor nameplate hp of all fans in HVAC system If yes, provide a seperate MECH-FANSYS form for each HVAC systein exceeding the Refer to Section C403.2.1/ and MECH-FANSYS-DOC for requirements and exceptions..- HVAC Hydronic Systems ■ Hydronic chilled water . • ■ Water -loop heat pump • 10 No hydronic systems • Ii Hydrant° heating water U Geothermal • " C406 Additional Efficiency Options - Mechanical - ora/r-to-waterheat be 15% more efficient than have FEQ z 71 and must be required ventilation akin a - of annual hot water energy use be 1•••••_,,,,,101-„••••ww.- ■ C406.2 More efficient HVAC equipment and fan systems Note 1- Constant Volume (CIO, Variable Air Volume (VAV), or HospitaULab CV system that qualifies for VAYbudget per C403.2.11.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list all fans (or groups of fans) associated with the delivery and removal o' conditioned air by the system. include all supply, return/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be Included if the fans do not operate at peak conditions. Note 3 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air b/ the system. Note 4 - This form automatically Identities whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes), or this Information Is not required because the system has a combined total nameplate motorhp.thar Is 5 hp or less (No) MECH-FANSYS Forms • . A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 511p. Select Add Fan - System Form) to generate an.additfonal form. Added forms can be deleted with button in cell E32pf the added form.• Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers manner that does not require space conditioning fan operation. - II C408.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% provided by heat pump, waste heat recovery or solar water -heating systems. •S#\./Ski 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1.. Mechanical Fan System Power Allowance MECH=FANSYS-SUNi 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 Project Title: Emerald City Graphics Server Room Date 1/1/2015 Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: . Emerald City Graphics Server Room For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. System or Primary Supply Fan ID . Speed Control (Note 1) Description . (Note 2) System Total Nameplate HP (Note 3) Fan Power Calculation Required (Note 4) CU -1 . VAV DUCTLESS CONDENSING UNIT 0.053 No .AH -1 VAV DUCTLESS AIR HANDLER 0.027 No Ii Total Bldg Performance (TBP) This path Includes all mandatory provisions per C401.2 Option 2.• " MECH-SUM, MECH-CHIS and 0407 Energy Analysls forms required. Design Load Calculations • • heating, cooling or Includes all applicable :": • El Load calculation summary in MECH-LOAD-CALC:Form -" Provide design load calculations for all mechanical systems and equipment serving the building ventilating needs. If a to 9d calculation summary is provided with the permit documents that compliance Information then the MECH-LOAD-CALL form is not required. Mechanical Schedules fomis arenot required, . El Mechanical Plans Ii MECH-EQ Forms (iBD) . indicate location of equipment compliance information. If provided on plans. then MECH=EQ however, include on plans all applicable compliance Information listed in MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV - Alternate • • • I DOAS Is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no ■ Ventilation provided via natural ventilation per 2015 IMC In lieu of DOAS (C403.6, • and space conditioning provided by a HEVAV system per 0403.7 In lieu Ventilation Ii DOAS included in project, although not required (occupancy not office, retail, education, ■ DOAS related allowances included in project: I■ Prescriptive vertical fenestration maximum area allowance Increased to 40% per conditioned floor area in building served by DOAS. - II .Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power exceeds Shp. 5 horsepower threshold. is Project includes HVAC air distribution systems that provide heating and/or cooling if yes, provide a MECH-FANSYS-SUM form. • For one or more systems, the total fan motor nameplate hp of all fans in HVAC system If yes, provide a seperate MECH-FANSYS form for each HVAC systein exceeding the Refer to Section C403.2.1/ and MECH-FANSYS-DOC for requirements and exceptions..- HVAC Hydronic Systems ■ Hydronic chilled water . • ■ Water -loop heat pump • 10 No hydronic systems • Ii Hydrant° heating water U Geothermal • " C406 Additional Efficiency Options - Mechanical - ora/r-to-waterheat be 15% more efficient than have FEQ z 71 and must be required ventilation akin a - of annual hot water energy use be 1•••••_,,,,,101-„••••ww.- ■ C406.2 More efficient HVAC equipment and fan systems Note 1- Constant Volume (CIO, Variable Air Volume (VAV), or HospitaULab CV system that qualifies for VAYbudget per C403.2.11.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list all fans (or groups of fans) associated with the delivery and removal o' conditioned air by the system. include all supply, return/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be Included if the fans do not operate at peak conditions. Note 3 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air b/ the system. Note 4 - This form automatically Identities whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes), or this Information Is not required because the system has a combined total nameplate motorhp.thar Is 5 hp or less (No) MECH-FANSYS Forms • . A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 511p. Select Add Fan - System Form) to generate an.additfonal form. Added forms can be deleted with button in cell E32pf the added form.• 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical SummaMECH-SUM, 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Title: . Emerald City Graphics Server Room Revised January 2017 Date " 1/1/2015 Project Information • Applicant information.. Provide contact information for Individual who can respond to " - Inquiries about compliance fort information provided. For Building Dept. Use - • Company Name: Comfort Mechanicai Company Address: - 3202 C St NE Auburn, WA 98002 ' Applicant Name: Jesse Chutich - _ Applicant Phone: •425 2519840 . Project Description Briefly describe mechanical systems In the text box provided ■ New Building ■ Building Addition " El Tenant Improvement ■ System Retrofit ■ No System Changes • Install (1)1 -ton ductless split system to serve server room: Ii Total Bldg Performance (TBP) This path Includes all mandatory provisions per C401.2 Option 2.• " MECH-SUM, MECH-CHIS and 0407 Energy Analysls forms required. Design Load Calculations • • heating, cooling or Includes all applicable :": • El Load calculation summary in MECH-LOAD-CALC:Form -" Provide design load calculations for all mechanical systems and equipment serving the building ventilating needs. If a to 9d calculation summary is provided with the permit documents that compliance Information then the MECH-LOAD-CALL form is not required. Mechanical Schedules fomis arenot required, . El Mechanical Plans Ii MECH-EQ Forms (iBD) . indicate location of equipment compliance information. If provided on plans. then MECH=EQ however, include on plans all applicable compliance Information listed in MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV - Alternate • • fire station occupancies) , air in a manner that does heating or cooling is required. Exception 1) •" . ' of DOAS (0403.8, Exception library or fire station) C402.4.1.4 with 100% of • I DOAS Is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no ■ Ventilation provided via natural ventilation per 2015 IMC In lieu of DOAS (C403.6, • and space conditioning provided by a HEVAV system per 0403.7 In lieu Ventilation Ii DOAS included in project, although not required (occupancy not office, retail, education, ■ DOAS related allowances included in project: I■ Prescriptive vertical fenestration maximum area allowance Increased to 40% per conditioned floor area in building served by DOAS. - II .Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power exceeds Shp. 5 horsepower threshold. is Project includes HVAC air distribution systems that provide heating and/or cooling if yes, provide a MECH-FANSYS-SUM form. • For one or more systems, the total fan motor nameplate hp of all fans in HVAC system If yes, provide a seperate MECH-FANSYS form for each HVAC systein exceeding the Refer to Section C403.2.1/ and MECH-FANSYS-DOC for requirements and exceptions..- HVAC Hydronic Systems ■ Hydronic chilled water . • ■ Water -loop heat pump • 10 No hydronic systems • Ii Hydrant° heating water U Geothermal • " C406 Additional Efficiency Options - Mechanical - ora/r-to-waterheat be 15% more efficient than have FEQ z 71 and must be required ventilation akin a - of annual hot water energy use be 1•••••_,,,,,101-„••••ww.- ■ C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) pumps and heat recovery chillers. All equipment listed in tables C403.2.3(f)-(7) must minimum requirements. All stand alone supply, return, and exhaust fans over flip must selected within 10% of maximum total or static pressure. • C406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers manner that does not require space conditioning fan operation. - II C408.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% provided by heat pump, waste heat recovery or solar water -heating systems. •S#\./Ski $ 1L.y.V.v•.v No changes shall be made to the scope of work without prior approval of Tukwila Building Division. TOTE: Revisions will require a new plan submittal . , , .. r,,f•.;rr i 'L t'1 r,.••..; ...,•, f.,. 1 • 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Economizer Exceptions 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all Ri Revised Janua 2017 Project Title: Emerald City Graphics Server Room Date - 1/1/2015 All cooling systems shall be configured to provide air economizer operation, regardless of . system capacity, for new construction and mechanical system alterations. Various exceptions to this requirement are available. Identify all systems that an economizer exception will be applied - to and additional information as noted below. For Building Dept. Use. Economizer ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS Exception Exp 1- - Cooling equipment serving 'spaces that are provided with a dedicated outdoor air system (DOAS)per `C403.6. Spaces served shall have year- Summary round design cooling loads front lights and equipment less than 5 watts per . square foot. Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and - - Table C503.4. System ID . . Lighting + Equipment Loads.(Wisf) Exp Single zone unitary or package systems with dehumidification that affect - . other systems such that air economizer would increase energy. - - consumption. Exp 3 High efficiency single zone unitary or packaged systems. Equipment cooling efficiency shall be better than the WSEC required minimum efficiency by at least 64% in Climate Zone 4C and 59% in Climate Zone 5B per Table C403.3. -• • CU . System ID . -1. AH- Exp 4 Equipment that provides hydronic chilled water for chilled beams and - chilled ceiling systems that is served by a water economizer system per C403.3.4 in lieu of air economizer. System ID . Cl t acttanical lectrical lumbing - Gas Piping Cil; of Tukwila "•_n!!,',..2.1 DIVISION Exp 5 . Water -source heat pumps with heat recovery. Heat pump efficiency shall be 15% better than WSEC required minimum efficiency: Provide at - minimum 60% air economizer. Energy recovery to preheat OSA shall have at least 50% effectiveness: Additional system requirements apply. Exp 6 - Cooling equipment serving Group R occupancies. Per unit limit is less than 20,000 Btu/h cooling capacity for equipment installed outdoors or in a mech room adjacent t6 the outdoors. For cooling equipment installed in other locations the unit limit is less than 54,000 Btu/h. Efficiency shall be 15% better than WSEC required minimum efficiency. System ID • System ID Equipment - Location Cooling .. Capacity (Btulh)Pip PIA Cooiinef a Capacity (Btuih) . Exp 7 Variable refrigerant flow (VRF) systems with energy recovery. Outdoor unit shall be a reverse -cycle heat pump with variable speed compressor(s) and condenser fan(s). Outdoor unit cooling capacity shall be not less than 65,000 Btu/h. Energy recovery to preheat outdoor air shall have at least 50% rated effectiveness. System shall be capable of providing simultaneous heating and cooling by tranferring recovered energy from zone(s) in cooling mode to other zone(s) that are in heating mode. Outdoor Unit System iD RE -y I S.i.ONS•-, DATE/:.. SCALE! pp Wirs Kinn i'3V .j. ' i3 ,uhlec to errors and omissions. )rovai cJ U r :s, , (iv l :ii: iF3t1tS1 Cees r1Oi E urnei IC violation of ).rl,; tl.dopted cede or ordinance. Rcco1pt proved Field Copy and co iditiis acknowed gid: Exp 8 Cooling equipment serving Controlled Plant Growth Environments. Equipment cooling efficiency shall be better than WSEC required minimum efficiency by at least 20%. Not eligible: unitary and applied " heat pumps. Exp 9 Cooling equipment with energy recovery. Spaces served shall have - - year-round design cooling loads from lights and equipment greater than 5 watts per square foot. Energy recovery systemshall utilize recovered energy for on-site space heating or preheating of service hot water. Provide calculations to the code official that demonstrate the amount of recovered energy used for on-site heating purposes is equivalent to the annual energy that would be saved by the cooling system with air economizer per C403.3: System ID SEER, EER, & • IEER City of T ikwila BUILDING DIVISION Lighting + System ID Equipment FOR IANCE ED EB 0 2 017 Y-14 City of Tukwila BUILDING DIVISION 00-000.: RECEIVED CITY OF TUKWILA JAN 302017 PERMIT CENTER I• USA/WA/Tukwila/ 1011 Andover Park E. 1011 Andover Park E. 1 SOLVENT. STILL c LLI OFFICE OFFICE CU -1 (ON ROOF) CLIENT' LOUNGE LOBBY CONFERENCE ROOM A :OFFICE: OFFICE CSR ESTIMATING OFFICE OFFICE. Q MI7 001b REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 2 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 302017 PERMIT CENTER