Loading...
HomeMy WebLinkAboutPermit M17-0019 - HOME DEPOT HEADQUARTERS - DIFFUSERS AND DUCTWORKHOME DEPOT H EADQUARTERS 370 CORPORATE DR N EXPIRED 09/13/17 M17-0019 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: httD://www.TukwilaWA.Qov 2623049144 370 CORPORATE DR N MECHANICAL PERMIT Project Name: HOME DEPOT HEADQUARTERS Permit Number: Issue Date: Permit Expires On: M17-0019 2/15/2017 8/14/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SOUTHCENTER CORPORATE SQUAR 150 CALIFORNIA ST, SAN FRANCISCO, WA, 94111 CONNIE HARDIN 4600 S 134 PL, SEATTLE, WA, 98168 HOLADAY PARKS INC 4600 5 134 PL , SEATTLE, WA, 98168 HOLADP1379NO Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2017 DESCRIPTION OF WORK: RELOCATING 3 DIFFUSERS AND MODIFY ASSOCIATED DUCTWORK Valuation of Work: $2,500.00 Type of Work: Fuel type: Fees Collected: $245.69 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: 3i 7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or I al laws r : ulating construction or the performance of work. I am authorized to sign and obtain this develop Hent ermi . agrte to t conditions attached to this permit. Signatur Print Name: r1 I► • •�(,� g l !\ Date L' I/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 2: ***MECHANICAL PERMIT CONDITIONS*** 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUK•A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov ‘05Z2 1441)1t - Mechanical Permit No. IV\ I 1� O l 6 Project No. Date Application Accepted: 71 Date Application Expires: t 1 11 (For office use only) . MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION 2 ' l King Co Assessor's Tax No. &(oa �' Qc. a (y( Site Address: J, Dfl.. N. Suite Number: Floor: Tenant Name: genri C. {40.1/4;;f"l�Ct5 New Tenant: ❑ Yes ❑ ..No PROPERTY OWNER Nam rrQS oar( aAddress:3 _ ,_ _ 1 ark Lj '�' Ir State:1 )& Zip 1 CONTACT PERSON — person receiving all project communication Name: Osortn(4,2 „�`n Address:4( 1O S``�i 9j2. Ci�..^ ty StatekZip4G t + s, b2) Phone 2� O Fal i, Zti�. (''O.7 Email:N Y1h1VRA 0 Vxota.t6.4AnctrICS titn MECHANICAL CONTRACTOR INFORMATION Company Name: r© , gaz ks Address:4(DQD % l3 Pip V r City: L Q State: �_ Zi c_, 43 r fie(t) Phon�io zso q S �J Fax zu p tr Contr Reg No i ,374, Frac 3Date: 4 3/24t. Tukwila Business License No us - mi(ioss Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Use: Residential: cletta44, New ❑ Replacement ❑ New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas El Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-416.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment lett14. f� V-461). Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI RIZED NT: Signature: � —"' ! , Date: I Print Name: 4tbb' (t n l a l/\ Day Telephone: ZbI Z �'"1, S 3 egl.;tt:te u)9.. 4V14/ City State Zip Mailing Address: 13 "l" H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT QUANTITY PAID $245.69 M17-0019 Address: 370 CORPORATE DR N Apn: 2623049144 $245.69 Credit Card Fee $7.16 Credit Card Fee R000.369.908.00.00 0.00 $7.16 MECHANICAL $229.36 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $150.34 PLAN CHECK FEE R000.322.102.00.00 0.00 $45.87 TECHNOLOGY FEE $9.17 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10752 R000.322.900.04.00 0.00 l $9.17 $245.69 Date Paid: Tuesday, February 07, 2017 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 00736G Printed: Tuesday, February 07, 2017 2:37 PM 1 of 1 PPSYSTEMS INSP TION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: tk)Ott I ar 1 -AO Tag of Inspection: eA.p&4 -'/.1 NI e=c ,cc L Address: 370 E A Date Called: Special Instructions: • Date Wante : 31)7//7 Requester,( 'CFg Phone No: 21 - l&sV q) ti '. Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector:A 'j REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 8/1/2017 City of Tukwila Department of Community Development CONNIE HARDIN 4600 S 134 PL SEATTLE, WA 98168 RE: Permit No. M17-0019 HOME DEPOT HEADQUARTERS 370 CORPORATE DR N Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/13/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/13/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, achelle ' ipley Permit Technician File No: M17-0019 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 ?ERMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0019 DATE: 02/09/17 PROJECT NAME: HOME DEPOT HEADQUARTERS SITE ADDRESS: 370 CORPORATE DR N X Original Plan Submittal Response to Correction Letter # Revision #, Revision # before Permit Issued after Permit Issued DEPARTMENTS: lug G (� Building Division 1)11j Fire Prevention ,4 kA /014 - Public Works Structural Planning Division ❑ Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 02/09/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 03/09/17 ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: I 14 cP=›Eitt (if)" REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 HOLADAY PARKS INC Home Espaiiol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I Page 1 of 3 A -Z Index Help , My L&I Workplace Rights Trades & Licensing HOLADAY PARKS INC Owner or tradesperson BECK, DAVID CARL Principals BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUIT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) WA UBI No. 578 004 089 4600 S 134TH PL SEATTLE, WA 98168 206-248-9700 KING County Business type Corporation License Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0.&SAW= 2/15/2017 HOLADAY PARKS INC Verify the contractor's active registration 1 licens Construction Contractor License specialties GENERAL License no. HOLADPI379NO Effective — expiration 01/21/1983— 09/03/2017 Bond LIBERTY MUTUAL INS CO Bond account no. 23000452 Received by L&I 08/23/2002 Insurance lification (depending on trade) and any past violations. Active. Meets current requirements. $12,000.00 Effective date 09/01/2002 Expiration date Until Canceled Charter Oak Fire Ins Co $1,000,000.00 Policy no. DTCO1F465357C0F16 Received by L&I Effective date 10/31/2016 11/01/2016 Expiration date 11/01/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 177,231-00 Account is current. Doing business as HOLADAY PARKS INC Estimated workers reported Quarter 4 of Year 2016 "Greater than 100 Workers" L&I account representative T3 / REAGAN MOREY (360)902-5135 - Email: MREA235@Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/22/2016 Inspection no. 317940948 Location 1007 Stewart St Seattle, WA 98101 No violations Inspection results date 08/09/2016 No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 2/15/2017 SYMBOLS LEGEND DETAIL TITLE A1.0-0 SECTION DETAIL (ENLARGED PLAN) ELEVATION SHEET NUMBER DETAIL I.D. NUMBER DETAIL TITLE SCALE: SCALE DRAWING SCALE A0.0-00 DETAIL I.D. NUMBER \\\ SHEET WHERE DETAIL IS LOCATED SECTION I.D. NUMBER SHEET WHERE SECTION IS LOCATED AREA TO BE ENLARGED 1 ) A0.0-00 ELEVATION I.D. NUMBER SHEET WHERE ELEVATION IS LOCATED CEILING HEIGHT DOOR WINDOW FINISH MATERIAL KEYED NOTES REVISIONS [Me-- 4./---COMMENTS, -1 4./— (COMMENTS, IF APPLICABLE CEILING HEIGHT ABOVE FINISHED FLOOR DOOR NUMBER DESIGNATION WINDOW NUMBER DESIGNATION FINISH DESIGNATION ELEVATION HEIGHT ROOM DESIGNATION KEYED NOTE DESIGNATION ON APPLICABLE SHEET ADDENDUM LETTER OR CHANGE BULLETIN NUMBER REVISED AREA CLOUDED �-ELEVATION HEIGHT 100'-0' T.O. SLAB ..---REFERENCE POINT SALES ROOM NAME AREA �- 101 ROOM NUMBER NOTE: FOR LIST OF ABBREVIATIONS AND DEFINITIONS, REFER TO SPECIFICATION (SECTION 01800) RESPONSIBILITY LIST DIVISION ITEM SUPPLIED BY INSTALLED BY POWER BY CONNECTION BY 8 DOORS AND HARDWARE GC GC EC EC 13 SECURITY ALARM GC GC EC EC 13 FIRE ALARM GC GC EC EC 13 FIRE PROTECTION GC GC - - 13 FIRE EXTINGUISHERS GC GC - - 15 DUCTWORK AND AIR DEVICES GC GC EC EC 15 HVAC UNITS GC GC EC EC 15 PLUMBING FIXTURES GC GC - - 16 ELECTRICAL PANELS: SUB PANELS & STEP DOWN TRANSFORMERS GC GC EC EC 16 LIGHTING GC GC EC EC GENERAL PROJECT NOTES A. DRAWINGS AND SPECIFICATIONS COMPRISE THE CONSTRUCTION DOCUMENTS. CONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY THE ARCHITECT IMMEDIATELY WHEN DISCREPANCIES ARE FOUND IN THE DOCUMENTS. B. CONTRACTOR SHALL PROVIDE AND MAINTAIN SERVICEABLE VEHICULAR ACCESS THROUGHOUT CONSTRUCTION OF THIS PROJECT. C. THIS DESIGN CRITERIA IS PROVIDED FOR BUILDING OFFICIAL REVIEW CONVENIENCE ONLY AND IS NOT INTENDED FOR USE BY COMPONENT DESIGNERS OR MANUFACTURERS AS THEIR SOLE DESIGN CRITERIA WITHOUT VERIFICATION. EACH DESIGNER AND/OR MANUFACTURER MUST INDEPENDENTLY CONFIRM ALL CODE CRITERIA WITH WHICH HIS ELEMENTS OR COMPONENTS MUST COMPLY, INCLUDING BUT NOT LIMITED TO LOADING, APPLICATION, FUNCTIONALITY, ETC. PERFORMANCE CRITERIA PROVIDED ELSEWHERE BY A SPECIFIC DISCIPLINE SHOULD BE REGARDED AS THE MINIMUM STANDARDS, AS WELL AS CODES, LAWS, ORDINANCES AND UNDERWRITER REQUIREMENTS GOVERNING THEIR PRODUCT AS WELL AS OWNER INSURER REQUIREMENTS, AS APPLICABLE. THE MOST STRINGENT OF THESE CRITERIA SHALL GOVERN. D. DO NOT SCALE DRAWINGS. E. GENERAL CONTRACTOR TO INSTALL ALL PRODUCTS PER MANUFACTURER'S MATERIALS' SPECIFICATIONS AND RECOMMENDATIONS. F. THIS BUILDING CONTAINS A COMPLETE FIRE PROTECTION SYSTEM. THE SPRINKLER SYSTEM MODIFICATIONS SHALL BE DESIGNED BY THE SPRINKLER CONTRACTOR'S CERTIFIED DESIGNER OR ENGINEER. THE SPRINKLER PLANS SHALL BE SIGNED AND SEALED BY THE SPRINKLER CONTRACTOR'S CERTIFIED DESIGNER OR ENGINEER AND SUBMITTED TO AHJ FOR APPROVAL. PLANS AND SPECIFICATIONS WHICH CONTAIN SUFFICIENT DETAIL FOR THE AHJ TO EVALUATE THE HAZARD AND EFFECTIVENESS OF THE SPRINKLER SYSTEM. CRITERIA BASED ON NFPA 13 MEET EXISTING HAZARD, GROUP OCCUPANCY DESIGN CRITERIA. G. THIS BUILDING CONTAINS A COMPLETE FIRE ALARM SYSTEM. THE FIRE ALARM SYSTEM MODIFICATIONS SHALL BE DESIGNED BY THE FIRE ALARM CONTRACTOR'S CERTIFIED DESIGNER OR ENGINEER. THE FIRE ALARM PLANS SHALL BE SIGNED AND SEALED BY THE FIRE ALARM CONTRACTOR'S CERTIFIED DESIGNER OR ENGINEER AND SUBMITTED TO AHJ FOR APPROVAL. PLANS AND SPECIFICATIONS WHICH CONTAIN SUFFICIENT DETAIL FOR THE AHJ TO EVALUATE THE EFFECTIVENESS OF THE FIRE ALARM SYSTEM. THE MODIFICATIONS TO MEET EXISTING SYSTEM DESIGN CRITERIA, FIRE CODE, AND NFPA 72 REQUIREMENTS . H. FIRE EXTINGUISHERS TO BE PROVIDED INSTALLED BY G.C. AT HEIGHTS DESIGNATED BY LOCAL FIRE CODE. FINAL FIRE EXTINGUISHER LOCATIONS SHALL BE APPROVED BY FIRE MARSHAL. CONTACTS ARCHITECT, MECHANICAL ENGINEER, AND ELECTRICAL ENGINEER: WD PARTNERS 7007 DISCOVERY BLVD. DUBLIN, 0HI043017 614.634.7000 BUILDING DEPARTMENT: CITY OF TUKWILA PERMIT CENTER 6300 SOUTHCENTER BOULEVARD, SUITE 100 TUKWILA, WA 98188 P11: (206) 431-3670 FAX: (206) 431-3665 SITE VICINITY MAP PROJECT LOCATION Mays Logistics and Operations Red Robin Gourmet Burgers OWNER THE HOME DEPOT U"S.A., INC. 2455 PACES FERRY ROAD, C.19 ATLANTA, GEORGIA 30339-4024 PHONE : (770) 433-8211 FAX : (770) 384-2392 CODE INFORMATION THE SCOPE OF WORK CONSISTS OF A REMIT OF LEASE SPACE BACK TO LANDLORD AND MODIFICATIONS REMAINING LEASE SPACE. USE GROUP DOES NOT CHANGE FROM ORIGINAL PERMITTED BUILDING. EXISTING BUILDING IS CONSTRUCTED WITH FIRE SUPPRESSION SYSTEM. A. APPLICABLE BUILDING CODE BUILDING CODE: ELECTRICAL CODE MECHANICAL CODE: PLUMBING CODE: FIRE PREVENTION CODE: ENERGY CODE: ACCESSIBILITY: 2015 INTERNATIONAL BUILDING CODE ADOPTED WITH STATE AMENDMENTS 2014 NATIONAL ELECTRIC CODE (NEC) 2015 INTERNATIONAL MECHANICAL AND FUEL GAS CODES ADOPTED WITH STATE AMENDMENTS 2015 UNIFORM PLUMBING CODE WITH STATE AMENDMENTS 2015 INTERNATIONAL FIRE CODE 2015 WASHINGTON STATE ENERGY CODE - COMMERCIAL ICC/ANSI A117.1-09 B. BUILDING CLASSIFICATION EXISTING USE GROUP: B - BUSINESS (PRIMARY) EXISTING CONSTRUCTION TYPE: VB COMBUSTIBLE BUILDING IS FULLY SPRINKLERED ABOVE AND BELOW CEILING EXISTING FIRE -RESISTANCE RATINGS BASED ON CONSTRUCTION TYPE: PRIMARY STRUCTURAL FRAMING: FLOOR CONSTRUCTION AND SECONDARY MEMBERS: ROOF CONSTRUCTION AND SECONDARY MEMBERS: C. OCCUPANT LOADING 0 HOURS 0 HOURS 0 HOURS PER TABLE 1004.1.2 UNOCCUPIED OFFICES TRAINING ROOM 2,499 / 0 6,671 / 100 = 1693 / 15 = OCCUPANCY LOAD TOTAL: CAPACITY OF EXITS DEFERRED SUBMITTALS: FIRE ALARM AND FIRE SPRINKLER 10863 0.0 67 113 180.0 320 D. EXIT CAPACITY PROVIDED EXIT CAPACITY REQUIRED: 180 x 0.20 = 36.0 EXIT CAPACITY PROVIDED: MIN. 2 EXITS REQJIRED - 2 EXITS PROVIDED EXIT ACCESS TRAVEL DISTANCE SHALL BE LESS THAN 250 FT, 187' SHOWN. MAXIMUM DEADEVD 20', 0' SHOWN. E. PLUMBING FIXTURE REQUIREMENT 64" FIXTURE PROVIDED (E) = EXISTING W.C. MALE W.C. FEMALE LAVATORY (EACH SEX) UNISEX ACCESSIBLE DRINKING FOUNTAIN SERVICE SINK NOTE: FIRE ALARM AND FIRE SPRINKLER SHOP DRAWINGS MUST BE SUBMITTED TO THE FIRE MARSHAL FOR REVIEW PRIOR TO INSTALLATION (E) 2 W.0 + 1 URINAL (E) 3 W.C. (E) 3 LAV. (EACH) (E) 1 W.0 + 1 LAV (E) 1 (E) 1 SERVICE SINKS ON FIRST FLOOR DRAWING INDEX DWG. NO. DWG. TITLE T1.0 TITLE SHEET ARCHITECTURAL REV. DATE 01/25/17 A1.0 DEMOLITION AND FLOOR PLANS A2.0 CEILING PLAN, ELEVATIONS, AND DETAILS MECHANICAL/ PLUMBING 01/25/17 01/25/17 M1.0 MECHANICAL PLAN P1.0 PLUMBING PLAN ELECTRICAL 12/16/16 01/25/17 E1.0 ELECTRICAL PLANS FIRE PROTECTION 01/25/17 FP1 FIRE PROTECTION PLAN FA1 FIRE ALARM PLAN 12/16/16 12/16/16 I SEP i Rt,TE PERMIT + (a: 2:�i; t �� FOR: 0�Mech Mechanical t2 ' Jectiical f FP robing Gas Piping Ci& of Tukwila BUILDING DIVISION REVISIONS No changes shaft h made to the scope of work without prior approval of U' 1R/Ha Building Division. NOTE: L: F , ,viso ns will require a new plan submittal and may include additional plan review fees. COPY Permit Not NII `1— ©01 61 Plan review t orovrl is subject to errors and omission3. Approval of ConSLr U :tion documents doss not a1I 10 iz13 the violation of any adopted code or ordinance. Receipt of approvedFf Cop ' nd 'onditio is acknoviledP3d: City of Tukwila BUILDING DIVISION REVIEWED FOR DE COMPLIANCE APPROVED 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM REMODEL TrIEM MIME 370 CORPORATE DRIVE N TUKWILA, WA 98188 EXIT=32" CAPACITY=16 FEB 13 2017 City of Tukwila BUILDING DIVISION SEPARATION REQUIRED = MIN. 33% OF DIAGONAL DISTANCE=19.7' SHOWN = 22' • ISSUE DATES PERMIT 1211646 BID 01T25N7 \ REVISIONS 1 SCALE 11/16" = 1'-0" SEE LIGHTING PLAN FOR EXIT SIGNS AND EMERGENCY LIGHTING RECEIVED CITY OF TUKWILA FEB 0 7 2017 PERMIT CENTER OTYPE VERSION N/A LIFE SAFETY PLAN - S OND FLOOR North OJECT NUMBER DPB51036 T1.0 I= File: P:WDP1851HOPB51036. WA Tukwila ' 3-BuiId1022-Arch Erg\WO-ConDocs\01 T1-0.dwa Last Saved: 1/25/2017 3:56 PM (wda29401 Last Plotted: 1/25/2017 3:56 PM (w,1a20401 CD ETR �C CD ETR OTYP rf CORRIDOR OPEN OFFICE AREA RELOCATE DIFFUSER CD ETR RAG ETR 1 RAG ETR 1 4 1 RAG ETR CD ETR )( ETR I CD ETR cS 11Y I - I VAV 12-211 I / ETR O I CD ETR I (ETR) 4 RAG ETR RAG ETR RELOCATE DIFFUSER RAG ETR ):C RAG ETR CD ETR OFFICE I S 12-20 (ETR) RAG ETR RAG ETR f f—VAV 12-206 ETR CD ETR RAG ETR S 12-20IP (ETR) VAV 12-208 ETR CONF. ROOM �t CD ETR 1 KITCHENETTE I RAG IETR .I /1 RAG ETR CD ETR GENERAL NOTES: A THESE NOTES AND LEGENDS ARE TYPICAL FOR THE ENTIRE JOB UNLESS STATED OTHERWISE. ANY CONFLICTS OF WORK SHALL BE BROUGHT TO THE GENERAL CONTRACTORS ATTENTION BY THE CONTRACTOR PRIOR TO PURCHASE OF EQUIPMENT OR COMMENCEMENT OF WORK. B MECHANICAL CONTRACTOR SHALL HAVE A GOOD WORKING KNOWLEDGE & ACQUAINTANCE OF THE EXISTING JOB SITE AS WELL AS THE CONDITIONS OF THE JOB SITE. C THESE PLANS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO REPRESENT THE ACTUAL SITE CONDITIONS. CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO COMMENCING WITH WORK. DO NOT SCALE THESE PLANS. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND SCALES. D MECHANICAL CONTRACTOR SHALL COORDINATE WITH OTHER DISCIPLINES AND CHECK CLEARANCES TO PREVENT ANY CONFLICTS. E PROVIDE OPERATION AND MAINTENANCE MANUALS FOR ALL EQUIPMENT AS REQUIRED IN THE SPECIFICATIONS. F ALL MECHANICAL WORK SHALL COMPLY WITH LOCAL, STATE, HVAC AND ENERGY CODES. G SHEET METAL DUCTWORK SHALL BE GALVANIZED STEEL SHEETS OF THICKNESS AS RECOMMENDED, CONSTRUCTED AS DETAILED PER LATEST SMACNA CONSTRUCTION STANDARDS. U.S. METALS ONLY. H BRANCH DUCTS SHALL BE THE SAME SIZE AS AIR DEVICE NECK UNLESS OTHERWISE INDICATED. I ALL FITTINGS AND TAKEOFFS SHALL BE CONSTRUCTED AS DETAILED PER SMACNA OR APPLICABLE CODES, WHICHEVER IS MORE STRINGENT. COORDINATE INSTALLATION OF GRILLES AND DIFFUSERS IN GYP. BOARD CEILINGS WITH THE CEILING INSTALLER. J K EMS SENSORS ARE PART OF THE ELECTRICAL SCOPE AND ARE SHOWN ON THE MECHANICAL DRAWINGS FOR REFERENCE ONLY. REFER TO EM DRAWINGS FOR DETAILS. L NO FOREIGN METALS WILL BE ALLOWED. M AS SPECIFIED IN SECTION 15010 ITEM 1.24A, ALL WORK SPECIFIED UNDER THIS DIVISION SHALL BE DONE BY SKILLED MECHANICS AND SUBJECT TO THE INSPECTION AND FINAL APPROVAL OF THE ARCHITECT OF RECORD. SUCH FINAL APPROVAL SHALL IN NO WAY RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR DEFECTS IN EITHER WORKMANSHIP OR MATERIAL, WHICH MAY SUBSEQUENTLY N DEVELOPED. p Go 4'u Ec < -(o L, ($ Zo (S (/-.0 keyed notes: O EXISTING VAV RE -HEAT UNIT TO REMAIN. SHOWN LOCATION IS APPROXIMATE. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. O EXISTING VAV SENSOR TO REMAIN. SHOWN LOCATION IS APPROXIMATE. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. O EXISTING VAV SENSOR TO BE RELOCATED AS SHOWN. SHOWN LOCATION IS APPROXIMATE. CONTRACTOR TO VERIFY EXACT LOCATIONS IN FIELD. CONTRACTOR RESPONSIBLE FOR ALL WIRING AND CABLE NEEDED FOR FULL RELOCATION. FINAL LOCATION TO AVOID ALL OTHER TRADE CONFLICTS. O CONNECT NEW DUCTWORK TO EXISTING SUPPLY DUCTWORK OF SAME SIZE. FIELD VERIFY LOCATION AND SIZE OF EXISTING DUCTWORK. O CONTRACTOR TO IDENTIFY ANY NEW FIRE DAMPERS NEEDED FOR THE NEW 1 HOUR RATED CORRIDOR WALL AND INSTALL PER ALL LOCAL CODES AND REQUIREMENTS. 5°71 ) Er training room hvac plan II SCALE 11/4"-1'-0" © TYP CD ETR <S 12-21I O RELOCATED /4-NlyN\ RAG ETR RAG ETR TRAINING ROOM RAG ETR CD ETR CD ETR VAV 12-210 ETR O CD ETR 1//RAG ETR RAG ETRETR OT4 CD ETR 1 <S 12-203j O RELOCATED I I RAG ETR ►il CD ETR RAG ETR VAV 12-209 ETR Qi CD ETR Ij 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM REMODEL 370 CORPORATE DRIVEN TUKWILA, WA 98188 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 132017 f Tu ISSUE DATES 1 PERMIT 12/16/16 I BID 01/25/17 �REvISIONs RECEIVED CITY OF TUKWILA FEB 0 7 2017 PERMIT CENTER Cl) z act I J C) WD PROJECT NUMBER V W 2 TING HVAC CONDITIONS TAKEN FROM SIMILAR AS BUILT DRAWINGS AND ARE MEANT FOR ILLUSTRATIVE PURPOSES ONLY. CONTRACTOR IS RESPONSIBLE FOR ON SITE IDENTIFICATION OF ALL EXISTING HVAC CONDITIONS ON SITE THAT ARE APPLICABLE TO THE SCOPE OF WORK SHOWN. IDENTIFICATION OF SHOWN CONDITIONS, AND COORDINATION OF SCOPE OF WORK WITH ALL TRADES. TOTYPE VERSION N/A HDPB51036 M1 File: P:WOPIB5WDPB51036 WA Tukwila 103-Buid102-Arch Eau\VVD-ConDacs\15 M1.dwa Last Saved: 12/19201811:45 AM fwda11991 Last Plotted. 1/2520173.59 PM fwds2A4n1