Loading...
HomeMy WebLinkAboutPermit M17-0020 - WESTERN FOODS - HOOD, DUCT WORK AND ROOF FANWESTERN FOODS 641 INDUSTRY DR M17-0020 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2523049008 Permit Number: M17-0020 641 INDUSTRY DR WESTERN FOODS Issue Date: 3/13/2017 Permit Expires On: 9/9/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: NCWP ANDOVER EXECUTIVE PARK 810 NW MARSHALLS ST #300 , PORTLAND, WA, 97209 PATRICK CONVERSE PO BOX 70 , FALL CITY, WA, 98024 ALL STAR HEATING & A/C INC PO BOX 70 , FALL CITY, WA, 98024- 0070 ALLSTHA044JK 111 Phone: (425) 766-1941 Phone: (425) 222-7652 Expiration Date: 4/12/2017 DESCRIPTION OF WORK: INSTALL HOOD, DUCT WORK, AND ROOF FAN. INSTALL ROOF GAS MAKE-UP AIR UNIT WITH DUCT WORK. Valuation of Work: $24,550.00 Type of Work: NEW Fuel type: GAS Fees Collected: $546.56 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Date: J ` J t I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: 3 l� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Type 1 Hoods, the required grease duct leakage test and (light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 8: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 9: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 10: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 11: Local U.L. central station supervision is required. (City Ordinance #2437) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 13: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 14: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL 0710 TYPE 1 HOOD AND DUCT CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M, 1 - x0010 Project No. Date Application Accepted: )—÷ 1 1 Date Application Expires: 4 , - 1 7 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 641 INDUSTRY DR. Tenant Name: WESTERN FOOD PROPERTY OWNER Name: PATRICK CONVERSE Name: S K B COMPANY City: FALL CITY State: WA Zip: 98024 Address: 617 INDUSTRY DR. Email: PATRICK@ALLSTAR-HVAC.COM City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: PATRICK CONVERSE Address: PO BOX 70 City: FALL CITY State: WA Zip: 98024 Phone: (425) 222-7652 Fax: Email: PATRICK@ALLSTAR-HVAC.COM King Co Assessor's Tax No.: Suite Number: New Tenant: 022340-0010 Floor: 1 m Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: ALLSTAR HEATING Address: PO BOX 70 City: FALL CITY State: WA Zip: 98024 Phone: (425) 222-7652 Fax: Contr Reg No.: ALLSTHA044JK Exp Date: 04/12/2017 Tukwila Business License No.: BUS -0994503 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: INSTALL HOOD, DUCT WORK, ROOF FAN. INSTALL ROOF GAS MAKE-UP AIR UNIT WITH DUCT WORK D'4S5®- Use: Residential: New Commercial: New Fuel Type: Electric ❑ Gas Replacement Replacement Other: GAS PIPE BY OTHER H: Applications\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-0-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 1 Floor furnace 55 dB(A) S u spended/wal I/floo `r mounted heater 57 dB(A) Appliance vent , Repair or addition to heat/refrig/cooling system 1 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system , Hood and duct 1 Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator , Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE D D EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TLA OFT E STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OIVAUT : ORIZED AGENT: Signature: (/ r � Date: 02/08/2017 Print Name: PATRICK CONVERSE Day Telephone: (425) 766-1941 Mailing Address: PO BOX 70 H:\Applications\Forms-Applications On Line \20I6 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh FALL CITY WA 98024 City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK$546.56 ACCOUNT QUANTITY PAID M17-0020 Address: 641 INDUSTRY DR Apn:2523049008 $546.56 Credit Card Fee $15.92 Credit Card Fee I R000.369.908.00.00 0.00 $15.92 MECHANICAL $510.23 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $375.03 PLAN CHECK FEE R000.322.102.00.00 0.00 $102.05 TECHNOLOGY FEE $20.41 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10759 R000.322.900.04.00 0.00 $20.41 $546.56 Date Paid: Wednesday, February 08, 2017 Paid By: PATRICK CONVERSE Pay Method: CREDIT CARD 00455G Printed: Wednesday, February 08, 2017 9:57 AM 1 of 1 CR SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 1 n , A. Type of Inspection: mai+ 1 fA L A1AL. Addre s: �4 / Arro s y . ate Called: Special Instructions: Date Wante y : Zi / / p.m. Requeste Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 MI? -00 Project:,,�° IA)CS�AI P �5 Type o spection: ' 12 vt i Nr& Addrq s: 614 ii 1,bs ev be Date Called: Special Instructions: Date Wante : (,i 21/17 I a.m p.m. Requeste . Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: 45)4/.1 Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 14117 P6.2-0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr eA t Atli i Type of Inspection: i1 l Z JJ M )cAG-AJ 4L- Addre s: of/ l, -y be Date Called: Special Instructions: CALL /Q iiiia Date Wanted 7 /�� � R a.m. p.m. Requeste . IK, ! Phone No: o-y4'lr 21/ LJApproved per applicable codes. Corrections required prior to approval. COMMENTS: b<AL- APPi2ovhz Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ct:Te btl i �ucSS of In pection: VC c-) J ./6- Address: d'/ / /Mb ('sr z V Date CaAled: Special Instructions: ie mitis Date Wanted: ii jt�i / 7 a.m p.m. Requester: Alec Phone No: 3ie- 4'Q/- 7ijg3. Approved per applicable codes. Ej Corrections required prior to approval. COMMENTS: Date: 4/Ie® 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 14417-0020 Project: k) I STERA) fvoD Type of I pection: • p/ P7DVC % / NS1V1-6-776.1+1 Address: 6ii/ moosTrzy DR, Date ailed: Special Instructions: Date Wanted: li—17—i7 a.rr p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Aro Ace ,Ess LusPErneAD Inspector: 44.1 Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: t'J '- " RN ffOD Type of Inspection: MECI444bdfi'L F/NAL Address: Date Called: 6W %Noo y Poe I Special Instructions: Date Wanted 41-1-H7 p.m. Requester: • Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /locas ) cw-riovf 26- caf e .��v -50E.C770.1 Inspector: Avgi REINSPECTION FEE REQUIRED. Prior to next inspection, fee must!be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION !i 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr 'e . Tyof Inspection: A. .ress: 6(11'be Date Called: Special Instructions: Date Want d: q i3 L7 a.m p' • Reques r: Phone No: y Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must'be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. If INSPECTION RECORD Retain a copy with permit MO- 0020 NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: b Type poff lnspectio 7/S 17 . / -1 `'6 d A diesss: 64/ / .//0w I Y / bie Date Called: _ Special Instructions: • Date Wante.a:� Requester. e tide Phone No: 142-5--776r= s-3 i‘ ri Approved per applicable codes. Corrections required prior to approval. COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD racopym Retain a withpermit INS'"' ON NO. P ►7-000 CITY OF TUKWILA BUILDING D 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 PERMIT N0. VISION (206) 431-3670 Pr gject: (.1.le7Zfis.! .b. Type of Inspection: r c i et D c Address: 6/4 1 tArNosivi tl ,f Date Called: Special Instructions: CALL fl?)oR Date Wante . ( a.m Requ ster Phone No: 4 7 - c390 ElApproved per applicable codes. Corrections required prior to approval. it COMMENTS: l i ate- DoT AP Inspector: 1 v REINSPECTION FEE REQUIRED. Prior to next inspection, fee must pe paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 11'41?` 662.0 Project: b 6 Te r rCob,S Type of Inspectio 'p/Ie 4 Hob f bc.er Address: ail Loin -ley De Date Called: Special Instructions: Date Wanted: I) 7/ 7 a.m Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: oiormeghe Gly 17 "TVPu? %L i 06- lis Pte/ Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD. Retain a copy_with permit - tt — PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: We- i\J . -b`> v Fire Alarm: Type of Inspection.: k 0d Address:r Suite #: Cc) M (1NJO4Lr tr Contact Person: Special Instructions: itt✓-- lilt / f"LL f- pP t -P /VQ2Z (E_ ,3 Lei c7 f t Iii- 77elo . 4- /OA " 6V14 -rte rh — KO 4 7-4" 5_S. r4-6-6 / Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: A Fire Alarm: -24A rea_ over piNG� ce1Ve�"1G A/672Les i '/q/ �ST ry 4-0..--4-s." 4 6-gni6 sr/124- per, %---a tJ ic, 7Y01z1964/1-' 5*- tx/ -T w t -x f1' s7 4 t r ►' N t`D r?i1 44 rf te-E v itt✓-- lilt / f"LL f- pP t -P /VQ2Z (E_ ,3 Lei c7 f t Iii- 77elo . 4- /OA " 6V14 -rte rh — KO 4 7-4" 5_S. r4-6-6 / 87H,✓ A/o-J. k(c S /C, by 5 7-79-u-e� IA) Needs Shift. Inspection: y -P.% Sprinklers: A Fire Alarm: -e-9 Hood & Duct: Monitor: /V LAJ B'K-04t (-Zi-( Pre -Fire: /t./P-�r%-e-d Permits: Occupancy Type: f - ( Inspector: 14.44 6 A''-- Date: q121 1 (-r Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn : Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 GENERAL NOTES ARCH / INTERIOR ABBREVIATIONS BUILDING SUMMARY PROJECT TEAM 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT 'GENERAL CONDITIONS,' AND BUILDING STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. x 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION IR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY OWNER AND/OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRTIING BOTH THE ARCHITECT AND OWNER OF ANY REARS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION INTU THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS V•1111 SHORTER LEAD TIMES. PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AU. WORK AND MATTRLALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. B. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. 00 NOT SCALE THE DRAWINGS. 9. THE USE OF WORD 'PROVIDE' SHALL ALWAYS MEAN. 'FURNISH MD INSTALL, CONNECT. OR SECURE' AS REQUIRED.REFIT 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS ANTRADE ASSOCIATES ACCEPTED STANDARDS. 1 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION REAS, AND START AND COMPLETION DATES OF EACH PHASE THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS 13. ACCESS TO AND FROM THE PROJECT SITE. SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK. INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES. RELOCATION OF STING EQUIPMENT, CASEWORK, FIXTURES. FTITINGS, ETC.. MUST BE COORDINATED WITH COSTING THE BUILDING MANAGEMENT. 14. ADEOUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEUNG TILES ANO/OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. t 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES. ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF AIM. CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY 111E LANDLORD WITH ONE SET OF RECORD' A5 -BUILT DRAWINGS. 18. ALL MATERIALS TO BE NEW UON. 19. PATCH ALL DISTURBED AND/OL DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AID A5 REQUIRED FOR FINISHED APPEARANCE 20. GENERAL CONTRACTOR 15 RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING. BLOCKING. AND FRAMING FOR UGHT FIXTURES, ELECTRICAL FIXTURES. CASEWORK AND ALL OTHER ITEMS REQUIRING R. 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. 22. ALL PALM AND FINISH MATERIAL COLORS SHALL MATCH MCHITECYS CONTROL SAMPLES.•- AND REQUIRE ARCH05 5 REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT AT LEASE THREE (3) COPIES FOR REVIEW. /F4 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAYANGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FUM_ A 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE UST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. ADJ AFF ALT ALUM APC APPRO% ARCH ACT AV gIDQ BOT CAB CL CLG CLR COL CONC CONT DEMO DEPT OF DIA DIFF DIM DEL DW DWG EA EL ELEC E0 EQUIP E FA 10 FE FEC FEE FIN FLUOR FIR FO FOIL ETC FURR GA 01. GWEI HC r HM NR INCE INFO INSUL LAV LE MATE MAX MDF - ADJUSTABLE MECH - MECHANICAL - ABOVE FINISH FLOOR - MEZZ - MEZZANINE - ALTERNATE MFR - MANUFACTURER _ALUMINUM MIN -MINIMUMBUILDING - ACOUSTICAL PANEL CEUNC MISC -MISCELLANEOUS - APPROXIMATE MTD - MOUNTED - ARCHITECTURAL - METAI. - ACOUSTICAL CEIUNG TILE - AUDIO VISUAL N/A - NOT APPUCABLE / -BUILDING NIC - NOT W CONTRACT - BOTTOM NTS - NOT TO SCALE - CABINET OC - ON CENTER - CENTER UNE OFF - OFFICE - CEINC UNG OPNG -OPENING - CLEAR OVIMD - OVERHEAD - COLUMN P - PAINT2015 - CONCRETE PARI - PARTf1ION -CONFERENCE PERF -PERFORATED - DEMOLITION PERIM - PERIMETER - DEPARTMENT PERP - PERPENDICULAR - DRINKING FOUNTAIN PIAM - PLASTIC LAMINATE - DIAMETER PLYWD - PLYWOOD - DIFFUSER QTY - QUANTITY - DIMENSION (R) - RELOCATED - DETAIL RA - RETURN AIR - DISHWASHER RCP - REFLECTEDEURNI CEILING PLM! - DRAWING REC - RECESSED - EACH INCE - ELEVATOR REF_ - ELECTRICAL - REFRIGERATOR -ELEVATION REL - RELOCATE - EQUAL REV - REVISION OR REVISED - EQUIPMENT RN - ROOM• -EXTERIOR RO - ROUGH OPENINGASSE - FIRE ALARM RTD - RATED - FLOOR DRAIN SCHED - SCHEDULE - FIRE EXTINGUISHER SF - SQUARE FEET/FOOT - FIRE EXTINGUISHER CABINET SHE - SHEET - FINISH FLOOR ELEVATION SIM - SIMILAR - FINISH SPEC - SPECIFICATION - FLUORESCENT SPKLR - SPRINKLER - FLOOR SPKR - SPEAKER - FACE OF SO - 50UARE - FURNISHED BY OWNER, INSTALLED STD - STANDARD BY CONTRACTOR STL - STEEL - FURNISHED BY TENANT. INSTALLED STOR - STORAGE 8Y CONTRACTOR - FURRING SIAL - STRUCTURAL -GAUGE STRUC - STRUCTURAL SIMM - SYMMETRICAL - GLASSS CONTRACTOR TBD - TO BE DETERMINED - GYPSUM WALLB0#J9) TEL - TELEPHONE OR TELECOM TEMP - TEMPERED - HANDICAPPED 1119 - THICKNESS -HARDWARE TO _TOP - HOLLOW METAL (SIERT.. FRAME) TOS - TOP OF SLAB HOUR TTP - TYPICAL INCLUDED OR INCLUDING UQN - UNLESS OTHERWISE NOTED INFORMATION UPS - UNINTERRUPTED POWER SUPPLY INSULATION VCT - VINYL COMPOSITION RLE LAVATORY VII - • VERIFY IN FIELD LINEAR FOOT W/ - WITH MATERIAL - WATER CLOSET MAXIMUM WC MEDIUM DENSITY FIBERBOARD WO - WOOD W/0 - WITHOUT WESTER1. PROJECT ADDRESS: ANDOVER FOODS ANDOVER INDUSTRY EXECUTIVE PARK, BUILDING 13 TUKWILA. WA 98188 AUK .WA 2. APPLICABLE CODES & ORDINANCES: 2015 INTERNATIONAL BUILDING CODE WITH STATEWIDE AMENDMENTS ICC/ANSI TEW10 MI ACCESSIBLE AND USABLE BUILDINGS AND FACILfilES, WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL RESIDENTIAL CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL MECHANICAL CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL FUEL CAS CODE WITH STATEWIDE AMENDMENTS (PMT OF THE ADOPTION 2015 INTERNATIONAL FIRE CODE WITH STATEWIDE AMENDMENTS UNIFORM PLUNGING CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL ENERGY CONSERVATION CODE/WASHINGTON STATE ENERGY CODE 2015 INTERNATIONAL EXISTING BUILDING CODE WITH STATEWIDE AMENDMENTS FOUND IN THE IBC NATIONAL ELECTRICAL CODE (NEPA 70) 3. GENERAL BUILDING DESCRIPTION: TYPE OF CONSTRUCTION: TYPE VB FIRE RESISTIVE SYSTEM: NON -SPRINKLERED OCCUPANCY TYPE 11 AND B, OFFICE 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: SHAFT ENCLOSURES:ECONN/A TENANT: GENERAL CONTRACTOR: Western Fascia TBD ANDOVER EXECUTIVE PARK, 13 PLUMBING ENGINEER: 641 INDUSTRY DRIVE TBD - Bidder Design Build byC.C. TUKWILA, WA 98188 9 ATTN: BILL HEPLER MECHANICAL ENGINEER: TBD - Bidder Design Build by C.C. ARCHITECT/DESIGNER: Burgess Design, Inc. ELECTRICAL ENGINEER: 1326 - 5th Avenue, Suite 400 780 - Bidder Design Build by G.C. Seattle, Washington 98101 Tel: 206.587.7120 FlRE/UFE SAFETY ENGINEER: ATT RANDY 2 .7122 TBD - Bidder Design Build by G.C. ATTH; RANDY MORGAN BUILDING PROPERTY MANAGER: Scanlan Kem rbord Componies P 617 Industry Drive Tukwila, Washington 98188 PLUMBING, MECHANICAL, ELECTRICAL, Tel: 206.575-6675 UFE SAFETY PERMITS UNDER SEPARATE Fac: 206.587.7122 SUBMITTALS. ROSS BECKLEY EXIT STAIR ENCLOSURES: N/A CORRIDORS: N/A LEGAL DESCRIPTION / . PARCEL N 0 . - - 5. EXITS: 5. APPROXIMATE AREA OF CONSTRUCTION: 6,114 SOFT TOTAL APPROXIMATE SUITE AREA OFFICE 1,618 SOFT (SEE 0.0.2 PIAN FOR DETAILS) TOTAL OCCUPANT LOAD FACTOR: 01110E 100, TRAINING: 20. ASSEMBLY: 15, KITCHEN: 200. WAREHOUSE: 500 NUMBER OF TOTAL PROPOSED OCCUPANTS: 86 OCC. (SEE G.0.2 PLAN FOR DETAILS) NUMBER OF DOTS REQUIRED: 2 REOUIRED; 2 PROVIDED MINIMUM EGRESS WIDTH REQUIRED: 3'-8' MAXIMUM COMMON PATH OF EGRESS TRAVEL: 75' (ACTUAL: 52'-8') 6. PROJECT DESCRIPTION: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT. WORK INCLUDES NON-STRUCTURAL 0EN0LIT10N. NEW PARTITIONS, DOORS. SIDELIGHTS, CASEWORK AND FINISHES. PARCEL NUMBER: 022340-0010 - LEGAL DESCRIPTION: ANDOVER INDUSTRIAL PARK #5 LESS UP RR OPER R/W ) y . r _ • STREET MAP DRAWING INDEX p ? L- 4 ' .., -' \ DRAWING ISSUED w �. _ - _ `sem �" '(-..... 1 �.-df .1 _« •b . - Y0�' - - 4,......„....1.1 i - j �' - AN.- 41 a n - pp u n /6. + ) j, 1 , .' } N, A - • / J 6 T1K i ,yw 1 ) w� o o S' ""�` _ t 'i A.' " ' �iA;:.,. F•wr- I' L GENERAL ) `_ly. Si. lda)„1�,..,. .t lie,........, X X X G.0.0 COVER SHEET / PROTECT INFORMATION - , X X G.0.1 PROJECT NOTES "'� sr, �, "- +'7 e. •Ls°�X % X G.0.2 SITE PIAN/PLUMBING . e; ... - ? _ I•y "Cf • s"" . i:..l 4 ARCHRFCTURAL / INTERIORS _ :•+ ^• ' 7 '} N X X X 6.1.1 DEMOLITION PLAN L + '- + ' F` X X X 0.26.1 CONSTRUCTION PIAN A }-t "� X X X 6.28.1 DEMO REFI FCXFX1_C0UNG PLAN .� ti] T ` I4 lrols....-.._...1..,,,,,,,,,,,,„„„,.. sF.a '$. \ y X X X A28.2 REFLECTED CEUNG PLAN Fr gg 1 e i --1.- :r ddd...«< �, ( % X X A2C.1 POWER & DATA PLAN lL�i 'f s $0,4%*d"P°"� X X X A D1 FINISH FlOOR PLAN }r C r1°W r • .,,,�� L - solddewrY w- F ( X X X 6.6.1 INTERIOR ELEVATIONS Yh ,: L ' X X X 6.9.1 DOOR SCHEDULE / SIDELIGHT SCHEDULE / DETAILS T �j T X X % 6.9.2 CEILING /DETAILS a�j i } X X X 6.9.2 CEILING / EELS - 7 S j R X X AA.4 DETAILS .f - w4 1 7� A rs g 1 1 '+Iw. cu R -'. ' DEFINITIONS AND DIMENSIONS KEY PLAN / FLOOR PLATE - 1 ":25' A. DEFlNMONs 1. 'TYPICAL' OR 'EYP' INDICATES IDENTICAL SYSTEM TICAL COMPLETE FOR THE CONDITION NOTED. 2. ^SIM• OR 'SIM.' INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO ILAR THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. 'AS REQUIRED' INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED 515109 A5 INDICATED IN THE PROJECT DOCUMENTS. •p�,.(���rr 4. 'ALIGN' INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN 5TWVGRI, TRUE AND PLUMB RELATION ADJACENT MATERIALS.•iI�C 5. 'CLEAR' INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS. J3- DIMENSIONS. ANDOVER EXECUTIVE PARK BUILDING 13 �• 641'� IND, T 9BRIV p((( IXC COT �� ///��� EXIT/ . 1' i IL F j y - / SYMBOLS / CITY OF ELEVERENCE SYMBOL 1 { INDICATES FINISHED ELEVATION REF U DETAIL ID f SURFACES TO ALIGN � DRAWING TITLE BAR . COMMON j j _ FEa 0 1 VVV FE L R DETAIL IDENTIFICATION TITLE 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED, 2. AUGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE 6.k PLUMB. DIMENSIONAL LAYOUTS/4ALL 8E IN THE FOLLOWING PRIORITY ORDER. A STRUCTURAL DRAWINGS B. LARGE SCALE DETAILS C. SMALL SCALE DETAILS D. ENLARGED PLANS AND SECTIONS E FLOOR PLANS 3. MINIMUM DIMENSIONS FOR ACCESSIBIL1Y CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED.7� 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - 'AF'i. 6. CEILING H0GHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEUNG GRID OR FACE OF FINISH MATERIAL FOR OTHER CEIUNG TYPES, UNLESS OTHERWISE NOTED. 7. DOCUMENTS LL DRAWN DIAGRAMMATICALLY. AND SCALED DIMENSIONS ARE APPROXIMATE. DENTSHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED. SHEET 140. 0GRAPHICAL SECTION REFERENCE SYMBOL DRAWING SCALE TITLEI LONGEST PATH OF EGRESS TRAVEL: 52'-8' I PERMI f + \\\ ® CLU Ur Ir I r /DR 1 ELEVATION SYMBOLS VFLOOR 5% 92'-0' +1'-0' NOMINAL FLOOR DETAIL REFERENCE SYMBOL I ELEVATION 1 / HEIGHT (ABOVE/BELOW) BUILDING SPACE /ROOM ID T .I L- _ J`c 910008 OFFICE -..- SPACE NAME COL.UMNOANp/OR GRID UNE S ABOL 1 1127 �- SPACE NUMBER irT - ��' �'. UIlLEN51 }J/4JNE O DOOR SYMBOL ' i i. 1 C _ _ 7� L ANGLE AT CENTERUNE QQt 0 DOCUMENT SHEET SYMBOL O -A.- KEYED SHEET NOTES CI t- GLAZING SYMBOL -+- REVISION NUMBER _ - EXIT IX 1 �� '' - V V Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement tor: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 BURGESS I YIEGIOF.. AF.CHITEC1l..E M npodedko 4 Irde sod pr pn5 HpM nosed c 1115 Approved lar CONSTRUCTION WORK SHALL NOT PROCEED WE. THE BUILDING OWNER / REPRESENTATIVE AND 9UILDIN0 TENANT HAVE GIVEN THEIR APPROVAL TO THESE CONSTRUCTION DOCUMENTS APPROVAL BY THESE PARTIES SNAIL BE INTERPRETED AS APPROVAL- DRAWINR FOR COMDR. FINISH $$aELL9�c1I1ffgOF1�5, 01 WORK AND ALL DIMFNS0 5 ROSTNEI9'9T}ERHER PANTY AS BEING NECESSARY �T0TYH9e-OPEM 0141. USE OF THE SPACE. FURNISHINGS, AND TENANT EQUIPMENT AHD „FURNITURE INSTALLATIONS. e .q DING i CONSTRUCTION AND/OR UUMTXIN of • OWNER FROM .1056. 0NSTRaID BY THE OOLATE SHALL 6 IH TFPRETE Br THE 0 GNER AS SHALL BE INTERPRETED BY THE DESIGNER AS APPROVAL W FULL OF THESE CONSIRUCIION DOCUMENTS B Bute+TFTHY BOTH E BUILDING OWNER / �RHNT>�HRR71yR� P4 -4 a ME Eu 1 -OF( CODE COMPLIANCE APPROVED FEB 14 2017 No. PEtyrof 1 UKWIIae „GUI SPRY ION A EjL.L41+.-11i./il IVSD UiCEhLALocatwn 8 2011 C�[1C Project Manager. Project No: 16.3405.00 4 RM COVER SHEET /1 PROJECT INFORMATION 046.: d,wn,e a 14' . 35'. ..el. rn4en 0(000141 II re.ced G.0.0 rREVISIONS No changes shall he made to the scope of work tAritho; t prior approval of Tuk�vi!a Building Division. NOTE: r evasions wiil r€gii,o a ns. ,/ plan submittal and may in:,:l, da additional Wan review fees. FILE COPY Permit No. M.«1OU Plan review cipprc'lr:l is subject to errors and on i ; , .,, Approval of� �i � b.` x:o documents does not au hc,:tie the violation of any adopted code or ordinance. Fice,j.pt of approved Reid Copy and conditions is : cit ,o !acia3d: Date: City of Tukwila BUILDING DIVISION �! M:-::cb rascal gcnIcat 'Pfu'mbing C23 Piping 1 i ;Aitwi!a { .._i (..sly?H icqON 3cd 11 6 53 11-1-r H000t tILkc Le -t10 oo-c 'xi,weilek (44(Q onvtbut.5 H 1 e,S ( or" Toe I co" 4 oob -Top 541' s te J MAIN ff (2171-8 OCCL__ PAINTED r(J - ITIRD;JGr. WAREHOUSE 2,660 SOFT/500 OCC = 3 OCC. OFFICE: 1,618 SOFT/100 OCC = 16 OCC. FREEZER FREEZER COOLER (21+8 OCC) OPEN OFFICE ADA RESTROOM ASSEMBLY (CONFERENCE): 378 SOFT/15 OCC = 25 OCC. JANITOR (21 OCC (114x 316 'Dioi c tcia c .„ 5- 804 SOFT/20 OCC = 40 OCC. 4, -- ro 1 388 /200 OCC ITCHEN: 2 OCC. • I 11111111011r c • (21+8+25 OCC) MAIN EXIT \ X \‘' 1,71 1 ° c 5 •RE Wgt) F / D 07 7,, iP 'CE 4rp3f:v/, , ; / / / , / / _1)eioiT.* ,. 11:1 U" iflUILDING DWI, 1P1C1 ,ii: / / // SUPPLY OFFICE OFFICE RECEIVED; OF TUKVVI FEBO82O11/ MIT CE TER / / . f . // / ,. .. / ., , / / / / / . ;./ @HANGER BRACKET AIDO FOR ST +DOFF § 101 25 < j 0 STAINLESS STEEL HANGER BRACKET B2 S/e' THREADED ROD HEAVY DUTY RODLOCK LOCKLOCK HUTS NOT ABOVE (1) BELO NOT PROv10 ® EXTRACTAIRE HVC STAINLESS STEEL ADJUSTABLE CARTRIDGE FILTER US PATENT)! 6.394.083 FILTER: ( #11 'I EFF �~ H x L AREA, OTY :AREA, OTY AREA. I QTY LAREAI 11,162010.51! X 5 `2.55 11616 `0.40 X 4: 1.60 . -- — — i 1 I —1 — — j� — TOTAL EFF AREA =' 4.15 _ — =`1 HOOD EX. CFM • TOTAL EFF AREA = FPM OPERATING RANGE OF THE FILTER (250 TO 1400 FPM) LIGHTING FIXTURE 1+-24, 36, or 48 H I III� 8 4.5 RECESSED LE.0. LIGHTS T SPECIFICALLY DESIGNED FOR CANOPY HOODS TEMPERATURE RATED T080'C (176°1) MEETS NEPA CODE 96 &NEC 410 TOTAL LUMENS OUTPUTS 2500 18 WA-RS(24126 WATTS (561.44 WATTS(48) MED ® LISTED ENCLOSURE W/ TEMP. MONITOR I-- 4-1 6 KNOCKOUT FOR)1'' CONDUIT (00. SIDE) 1#�Fi TEMP. MONITOR' PATENT PENDING REMOVABLE COVER ALLOWS EASY ACCESS FOR INSTALLATION, ADJUSTMENTS AND SERVICE OF MONITORING EQUIPMENT FROM UNDER THE HOOD. TOR VAMIC SEE CCUIL. EXHAUST COLLAR DETAIL f 1R r BALANCEAIRE r FLANGE AT TOP AND BOTTOM OF COLLAR ALLOWS FOR DUCT CONNECTIONS N.T.S. EXHAUST COLLAR APPROVAL OPTIONS ❑ SHIP COLLAR LOOSE WELD COLLAR TO HOOD (DIMENSIONS REQUIRED) DRAWING APPROVAL THIS DRAWING MUST BE REVIEWED. SIGNED 8 RETURNED TO STRENOR AR SYSTEMS PRIOR TO THE START OF FABRICATION. VERIFY THE FOLLOLMNG: 1. ALL DIMENSIONAL INFORMATION, MOUNTING LOCATIONS 6 CLEARANCES. 2. THE LOCATION & TYPE OF COOKING EQUIPMENT. APPROVED FOR FABRICATION APPROVED ❑ APPROVED AS NOTED ❑ REVISE 8 RESUBMIT APPROVED BY DATE NOTE TO RENEWER: ANY CHANGES IN COOKING EQUIPMENT SUCH AS EQUIPMENT POSITION, TYPE AND/OR INCREASE IN ENERGY OUTPUT MAY AFFECT EXHAUST AIRFLOW. STRENOR AIR SYSTEMS MUST BE NOTIFIED OF ANY CHANGES THAT OCCUR PRIOR TO FABRICATION.A RE-ENGINEERING OF THE EXHAUST AIRFLOW MAY BE REOUI1100. HOOD SCHEDULE EXHAUSTLONER DOSE OF HOW OPER SCES TEMPERADOR2 C00.0 SURFACE MAMA. OVERRAN, MAP OUT./ ELECTRICAL SCHEDULE ET LIGHT FIXTURE WIRING DETAIL @SINGLE TEMP. MONITOR (STM) WIRING DETAIL L1 ® CDL3) OCT) c moor, OESCRIPiOH VOl'Y OFROM >MI "^° "cc^nP ..neA.F hoop I LIGHTS EE CB c... O�-_ mNp�w = um LJ LJ NO. MODEL L W H WEIGHT SPEC. CFM MIN. CFM SP MIN. MAX. , SIDE FRONT MAX. STMHF n 11 SAWCBD180 1685124 168 51 24 1149 2973 ... 0.77 36 48 6 6 600 ce CIRCUIT BREAEL£CTRKAL CONTRACTOR NOTE: AN ELECTRICAL CONTROL PANEL FOR THE 110005 INCLUDED, THE ABOVE SCHEDULE IS NOT VALID. REFER TO DEMANDAIRE DRAWINGS. ELECTRICAL LEGEND HOOD CANOPY MATERIAL: 304 STAINLESS STEEL WHERE EXPOSED ' HOOD LEGEND : pj ALL WELDED ENCLOSURE ZO 165A. SIDES. REMAINDER OF H000 TO BE 1 NO LESS THAN 18 GA. O PITCHED GREASE DRIP TRAY ® ENCLOSED METAL CONTAINER 0 CONTAINMENT PANEL: LIGHT DUTY © ENCLOSUREPANEL NOTINCLUDED p UTILITY CABINET (1 12,000 OVERHANG IS RECOMMENDED FOR ALL HEAVY DUTY COOKING APPLIANCES 0 E' ROUND INTERNAL HOOD FAN (IHF) COLLAR WITH UL LISTED FIRE DAMPER 8'X6' 10 E' ROUND RF SUPPLY DUCT (SHIPPED LOOSE) OEMAN DARE CONTROL PANEL INTERNAL HOOD FAN WISPEED CONTROL SEE ELECTRICAL SCHEDULE- CONSULT FACTORY FOR ALTERNATE NPUT POWER LOCATIONIS) STREIVOR FACTORY WRING FIELD WRING BY OTHERS LIGHTISH JUNCTION BOX TEMPERATURE MONITOR(S) JUNCTION BOX INTERNAL HOOD FANIS) JUNCTION BOX INTERNAL HOOD FAN (IHF) WIRING DETAIL — FJ TJ " O.A. -- 29 29 45 29 29 12 L�\ (SA )OPTIONS FOR SUPPLYING MAKE UP AIR TO THE SMARTAIRE INTERNAL HOOD FANS (INF) A. TRANSFER AIR - M /CAPLENUM B: TRANSFER AIii `C: OPEN AIR ',DIRECT DUCTTRANSFER NOR S000 INNER FRONT EDGE 0,F MOORS STREd pAINWARDDIRETIOMSCOMRg.MAETECcnFIiTLrM OkY THE IIWOE INCLUDE ISORECTAI N UPWORDCN VELOCITY eSIREnm IDIRECTED DOwNHAD.IINAAONERRD DIRERONT CTION. IWaWYY STREAMS HOODS AN TRE THERMAL PL.. A IDCOOMHO EFFLUENTS GENERATED FROM COOKING AFPUANCES LINER THE /OW THE A:STREAMS ARE LOCATED WITHIN THE HOODS CANT`, AND ARE THEREFORE CONSKEREO TO eE (EwLCEMENTFV MP.SATIIGI R. ASH.. ASI 110.1 AND CAxgweA TRE 2: ENERGY CODES VW THE AwLINT OF FERwCEMENT AR THAT CAN BE MTROdxED IrtO A.00 TO logo THE H000 EXHAUST ARROx PATE HE SAAVC20 WOOS INCLOOE A0EH H 1O F4450AAANT *WOE OIE ET !RCM SIAAA ENSURE PLENUMLEWTO&4ME FAa1A HAVETHE C-ARAEN.ITY NO I 0 OF OVERSCCOOMRFEi CIC PRESSMERS OFUPTO p. 25 P1 RATER COLUMN Aro CAN RANSPERARNIO DESMNT H000 PLENUM. EFFORTS n NAi Rua( AS ATJKu T FDP THE TE H u 00XD003 WITH S. RTARE TECIASOlOOY REQUIRE A SOLACE OF ¢.ANAIR TO PROLHOE TO OE Two INTERNAL AIR STREW. THE SOURCE OFCLEAN AIR CAN BE PwNOEDST TRANSFER 001 • MU/. PLENUM: FOR ROODS PROVIOED WITH MAKEUP OAR PLENUMS: - DIRECTLY...C.4 THE EIVOR DC. OPEN AIR: . OPEGTou[T dND. TRANSFER DIRECTLY Oft INDIRECTLY CONNECTING A TRANSFER AIR SOURCE TO TNE WARTA,. INTERNAL XGOD FAN COL LARM AL MOO FAN NBCTINOA FORCER MAKE UP AIN SQU SPACE TINTO THE ..AIRE PLEENUM FAN COLRuaI HEDe ROUNDH:SwPLrvJeiiO THEH000 MAKEUP AIR PLENUM ECTLY CE TO VIE (30x09x08) 2973 CFM 0.77 SP FIN. CEILING HOOD #11 PLAN VIEW HOOD #11 ELEVATION VIEW 51 54 O.A. �V ,f4-kAA it (?)1011i(A44-4-4 Eira ice. d (87Pao� V.I.F. 24 78 TO 84 ADA REQUIRES 80 MIN. HOOD #11 SECTION VIEW S�'w��S 0. S GENERAL NOTES: NOTES TO ARCHITECT ANO/OR CONTRACTOR: STREIVOR. INC. (STRENOR AIR SYSTEMS. STREIVOR STAINLESS) 15 A SPECIALIST 15 5/5 LAYOUT AND DESIGN OF KITCHEN VENTILATION SYSTEMS. AND IN NO WAY PURPORTS 00 BE ARCHITECTS OR ENGINEERS. THIS PLAN IS SUBMITTED FOR THE CONVENIENCE OF THE ARCHITECT AND/OR CONTRACTOR AND 15 ' DONE FROWAVAMABLE ARCHITECTURAL INFORMATION. ALL MEASUREMENTS ARE SUBJECT TO PHYSICAL VERIFICATION AND ANY DEVIATIONS OR DISCREPANCIES SHALL BE DIRECTED TO THE ATTENTION OF STRENOR, INC. IN WRITING. STREIVOR. INC. ACCEPTS NO RESPONSIBILITY FOR WORK DONE BY SAID ARCHITECT OR GENERAL CONTRACTOR OR THEIR REPRESENTATIVES OR SUBCONTRACTORS, AND WILL NOT STAND ANY : EXPENSE FOR CHANGES MADE NECESSARY DUE TO LOCAL BUILDING CODES, ORDINANCES. STRUCTURAL CONDITIONS. OR BY ANY SUBSTITUTIONS OR CHANGES IN EQUIPMENT SHOWN ON THIS PLAN. ANY ERRORS. AMBIGUITIES OR OMISSIONS IN THIS PLAN OR SPECIFICATIONS SHALL BE REPORTED i TO STRENOR. INC. FOR CORRECTIONS BEFORE ANY OF THE WORK IS STARTED. UNLESS EXPRESSLY STIPULATED. NO ADDITIONAL 1 ALLOWANCE WILL BE MADE IN FAVOR OF THE OWNER ORCONTRACTOR. BY VIRTUE OF ERROR. AMBIGUITY OR OMISSION WHICH SHOVED HAVE ' BEEN DISCOVERED DURING THE PREPARATION OF : BID ESTIMATES. AND DIRECTED TO THE ATTENTION OF STRENOR, INC. INA TIMELY , MANNER. PRE -INSTALLATION OBTAIN. READ AND UNDERSTAND STREIVORS HOOD INSTALLATION. OPERATION AND MAINTENANCE MANUAL PRIOR TO INSTALLATION. STARTUP OR BALANCING. INSTALLATION ALL INSTALLAT0N. STARTUP AND BALANCING MUST BE PERFORMED BY QUALIFIED PERSONS ' AND IN ACCORDANCE WITH ALL APPLICABLE 1 PREVAILING CODES AND STANDARDS. A IR MINIMUM CLEARANCE IS REQUIRED ABOVE ALL STANDARD CONSTRUCTION HOODS. CONSULT THE FACTORY FOR 00005CES. REVIEWED FO CODE COMPLIANC APPROVED FEB 14 2017 ' PROJECT WESTERN FOODS City of Tukwila BUILDIN 3 D1 /ISION RECEIVED CITY OF TUKWiLA FEB 08 2011 PERMIT CENTER 541 INDUSTRY DRIVE TUKWILA, WA98188 VOELLER & ASSOCIATES ' HOOD It: DATE: 10!072016 SC ALE:FAAHFnhn.N0..OE., 112 = 1'-0. ON[pwwac DRAWN BY MNG CHECKED BY: JWS CONSULTANT: VOELLER 6 ASSOCIATES 1 Q DESCRIPTION DATE INT : — SHEET: H-01 SHEET 01 OF 01 Copyright 0 2016 00eivOl. IRC. LISTINGS & CERTIFICATIONS COOKING EQUIPMENT VERIFICATION VERIFY THE FOLLOWING: THIS WET CHEMICAL EXTINGUISHING SYSTEM__ HIGH BACK SHELVES OYES 0 N RANGES WITH OVER A 28" COOKING SURFACE DEPTH OYES 0610 CEILING HEIGHT '-_ PULL STATION LOCATION(S) OAPPROVED UTILITY CABINET LOCATION(S) ['APPROVED APPROVED BY DATE Or..El IS PROTECTION PROTECTION FOR RESTAURANT HOODS, FOR E ENGINEERED -TO -PROVIDE -FIRE NT COOKING APPLIANCES, IS 300 :: �: 11'')i SYSTEM #FS1 - HOOD #11 INSTALLER: _-_ DUCTS AND UL LISTED AND 15 TO BE INSTALLED IN ACCORDANCE 1 T 3414 48 SS11.4 � "STRIVING FOR EXCELLENCE" 2150 KITTY HAWK ROAD, LIVERMORE, CA 94551 PHONE: (925) 960-9090 FAX:(925) 960-9055 WWW.STREIVOR.COM WITH THE FOLLOWING STANDARDS: RE iED FOR CD PLIANCE AP/ PROVED PROJECT: FEOFFSij pq 541 INDUSTRY DRIVE CIltyT ®/1 tWoulia U I LCEIEthdG8, DiViZIC)N �SMSSEId.# . Fite _-s HOOD#: 11 , SCALE:A.0 0ree5aumE0 1/7=1'-0' .'A� AWN BY. KCS CHECKED BY: HLF CONSULTANT: VOELLER 8 ASSOCIATES EDITION DESCRIPTION DATE INT A �r -1-a- — A — -/-4- — A — • NFPA 17A 2013 NFPA EDITION — ® ..... — Q - - jI SHEET: F-01 SHEET 01 OF 01 Copyright 0 2017 Streivor, Inc. l ` • 102013 uo��' • NFPA 96 2014 EDITION MF A • ALL APPLICABLE CODES nI l ' „*. INSTALLATION REQUIREMENTS: lit 1 1. ALL PIPE SHALL BE SCHEDULE 40 BLACK IRON. CHROME PLATED/SLEEVED WHERE EXPOSED. 2. PCL-3PCL-460 CYLINDER SYSTEMS SHALL HAVE 3I8" SUPPLY LINES AND 3l8"/8" BRANCH LINES. 3. ALL WIRE ROPE SHALL BE 1/16" STAINLESS STEEL AND RUN THROUGH 1/7' EMT CONDUIT. -17-1-19 90y CYLINDER #1 ✓ / / I� _ i v 4 U.L. LISTED CORNER PULLEYS REQUIRED WHENEVER THE STAINLESS STEEL CABLE DIRECTION CHANGES. 5. ALL EQUIPMENT WITH FIRE PROTECTION MUST BE SECURED TO FLOOR. 6. SWIVEL ADAPTERS MAY BE ADDED TO NOZZLES FOR UP TO 301 ROTATION. 7. REQUIRED CLASS "K" FIRE EXTINGUISHERS (NOT SUPPLIED BY STREIVOR) TO BE INSTALLED WITHIN 30 FT OF HAZARD - NFPA 10. 168 12 ^� �� Ste• SYSTEM #FS1 It D9 EA,C CYLINDER #1 t10 'V oi W C r 4 COVERAGE DESCRIPTION NOZZLE QTY. „FICA III / 1 410 N['['DUCT 2D 1 2 3-1 • 0 PLENUM 1 H 2 2 3-3 PLENUM NOZZLE COVERAGE ❑ ID M RANGE 2 L 1 2 3-7 1H: 120 LONG x 48 WIDE i� OP ❑ El 111 CHAR BROILER - 1 H 1 1 3-11 / 4D 4C IF.- 0 U FRYER 2 H 1 2 3-5 TOTAL FLOW POINTS 9 PIPING LIMITATIONS • 168 X 18 - CYLINDER FLOW POINTS TOTAL FIRST TO LAST NOZZLE LENGTH- VOLUME LENGTH' VOLUME MAXIMUM 10 50.93 FT 1910 ML 3000 FT 1125 ML DUCT NOZZLE COVERAGE PCL app ALLOTTED 9 30.00 FT 1125.0 ML 28.00 FT 1050.0 ML 2D: 100' PERIMETER• GENERAL NOTES: SUPPLY AIR SHUTDOWN SEQUENCE f-30 t 1. NFPA 96: SECTION 8.3.1 The internal fan(s) are engineered to shut down upon fire suppression activation per the REPLACEMENT AIR QUANTITY SHALL BE ADEQUATE TO PREVENT NEGATIVE PRESSURES IN THE COMMEROAL COOKING AREA(5)FROM EXCEEDING 4.98kPa (.02 IN WATER COLUMN) NFPA 96 standard. Internal compensating hoods must be fitted with listed fire dampers with fusible links at all 2. NFPA 96: SECTION 8.3.2 openings that penetrate the liquid tight enclosure of the hood, per NFPA 96 and U1710. WHEN ITS FIRE -EXTINGUISHING SYSTEM DISCHARGES, MAKEUP AIR SUPPLIED INTERNALLY TO A HOOD SHALL SHUT DOWN. The Smartaire hoods include penetrate the liquid tight enclosure UL 90a listed damper(s) with a fusible link at all openings that of the hood. Iit4r1 iVg PI1 lik n I I K 'I ` 110 C-- ' v I CABLE/LINE LIMITATIONS A LENGTH PULLEYS BRACKETS A FUSIBLE LINK MAXIMUM 150.00 FT 40 20 I (P945) ALLOTTED 15.00 FT 4 . 3"" '' II ''I II'' 1 O O O PULL STATION(S) MAXIMUM 150 00 FT 40 N/A T>) T SU7 44y� 1 (p9. 410) ALLOTTED 3000 FT 2 N/A _�e0 �� -->'"C e0 e0 e0 ep ,� - GAS VALVE(S) MAXIMUM 10000 FT 30 N/A FRYER CHAR- RANGE OVEN (pg. 4-11) ALLOTTED ALLOTTED -FT - N/A BROILER 2H: 19x19.5 2L 28x28 PAGE NUMBERS REFERENCED F PA SUPPRESS. SS1ON sysreu TECHNICAL MANUAL 1M: 24 x 26 Q:.......... ,ss (No SVPPUED ST RATING BE VER"MAME FUSIBLE IW INCLUDED VATIP FIER AxppnE PAINED IN REM .063 P SIBLE UNK TEMPERATURE 1: 0 LEGEND - Ic;:;... :• -� ` r12_.24� •••• •• •••••••••••••♦•\:•• •••••••••• •: SMARTAIRE HOOD W/ moo SYSTEM SIGNAGE �18� 4.‘•••11:•••••. INTERNAL SUPPLY AIR FAN DETECTION LINE ROUTE - - PAC -10 1 1 L� PATH OF EGRESS O Ep::180 1 i 260 I® 24K ®LFHER PULL STATION DUCT NOZZLE \ `' GAS VALVE 100 MB Rft RESET RELAY 61 "U) CONTROL HEAD m MAX PERIMETER PLENUM NOZZLE MAX PLENUM LENGTH APPLAINCE OZZLE AND HEIGHT (---.------) Ill 0 • C DETECTOR BRACKET r1 (FRONT VIEW) NOZZLE (PLAN VIEW) FACING I m DETECTOR BRACKET ©DONOZZLEWNWARD 1 (PLAN VIEW) re4D4••...... ""••4 SCALE: 1/4" = 1'-0" `q _ NOZZLE COVERAGE ® 1 ANGLED NOZZLE AND TARGET LOCATION P SYSTEM # -HOOD #: 4 PULL STATION (PART # 551074) NMCH3 CONTROL HEAD (PART # 551203) ELECTRICAL SWITCH (PART # 551154) ALARM SWITCH (PART # 550077) MECHANICAL GAS VALVE . FLANGED Y STRAINER /555085o.NOT SUPPLIED enSTREW. RECEIVEDWILA A IPA 2013 EDITION CITY OF Tl1K 52.1.1 IAPPL PULL .ABOVE1HEFLWRHFP ,AttED�.DRETHAN � 050[raTxx NAL TAIW W.MWIxED, WLSEC p W, ED, WT,OcoxrxOL xBM ZnITP6'iNtrICINTP NEPA 66300EDDION ,Bs.,., BE �EM M w, x CONTROL 0000 N0.il O COM EDITION THE CAS ,,, ,,y" " KIM[' DMPROTECTED �� -6.0-1===4,41...='N.O. OPENIaIACNI "`^^""^• INLET nOTNEW KITCHEN APPLIAN iMN THE00 AB of EGREss. ���� 311, _ •DBEDIBRDw, POWEROF FUEL AND ELECTRICAL K AS POSSIBLE. a 0 8 2011 11=MP d'er= PRESS .NNECTOR ,„q TIGHTLY O `PROTECTION y.�„ �,;��..�wF �j FASIBLE L. of '!� ,.ARM ��-� •RBB LrvDiBEREWIREpieBWTDDw Dry -�EDBEDIBRawx,��� A wno.,,,,,,,...... LACE PUTE (V • WxrvEcilory ��BLE ACTUATION ALL GAS AND POWER PIPP xO,EC,ED EuuOSTxWD,oACTUATING ARM j�e�jE,AxGEp Ex o ,,�i ,WrvxE :b.; TIWSYSTEM EP,ELD 4REDIx,gBDlLttx�PIRE D REDI DBDILttxDPIREGAFIEPONA TIVANOEM Yp„L ABL`• ST. ERCA TAINLESS STEEL PERMIT CENTERp 7.1AITLI2 r 'TOT xx BLED . SWITCH IS RATED AT36DVAC.c,ARESISTIVE:250 VAC.3HP,nruoc HP B ,DxIBRRPA ,EDA,EM MY D ��5.0. - SEE PAPP DRAWN. FOR LOCATION SCREEN 11 i CUSTOMER APPROVAL COOKING EQUIPMENT VERIFICATION VERIFY THE FOLLOWING: HIGH BACK SHELVES OYES 0 N RANGES WITH OVER A 28" COOKING SURFACE DEPTH OYES 0610 CEILING HEIGHT '-_ PULL STATION LOCATION(S) OAPPROVED UTILITY CABINET LOCATION(S) ['APPROVED APPROVED BY DATE Or..El uwuvoOTE asua.em.<oE,��w:,..a 7D.C44 INSTALLER: _-_ GENERAL aNOTES: wppP16m ��wREL16 SS SliLLAII "STRIVING FOR EXCELLENCE" 2150 KITTY HAWK ROAD, LIVERMORE, CA 94551 PHONE: (925) 960-9090 FAX:(925) 960-9055 WWW.STREIVOR.COM RE iED FOR CD PLIANCE AP/ PROVED PROJECT: FEOFFSij pq 541 INDUSTRY DRIVE CIltyT ®/1 tWoulia U I LCEIEthdG8, DiViZIC)N �SMSSEId.# . Fite _-s HOOD#: 11 DATE: 0127/2017 SCALE:A.0 0ree5aumE0 1/7=1'-0' ..or . ,..".= MMTAMMEIZZLI AWN BY. KCS CHECKED BY: HLF CONSULTANT: VOELLER 8 ASSOCIATES A DESCRIPTION DATE INT A — -1-a- — A — -/-4- — A — -/-4- — A — -1-1- - - -1-1- SHEET: F-01 SHEET 01 OF 01 Copyright 0 2017 Streivor, Inc. l ` 1 �Q . m co D V) c> r0 0 E D Wm CO'N L N 9, CO 11 n I 4.13 CO %0 U1 N c A 3 1:13.1.N33 i1w113d N 0 a N N c+� 0.2.Z . y r N E w 4 c m c K S H.000.02 x 1.000.6L x P.0001E ci ^m D m eA DD A � m D J fN1 N Dd 9m m O0 7, V < y K m O D'� S A m" Am d OE cr zr N cm Z �- OyZ 0I 1 - Size 2 Direct Fired Heater Low CFM Profile Package. Used on Heaters under 2500 cfn. 1 - Separate 120V Wiring Package (Required and used only for DCV or Prewlre with VFD) - Three Phase Only 1 - Manifold Pressure Gouge, -5 to 15' we 1 - Extra Set of Belts 1 - Low Fire Start 1 - Inlet Pressure Gauge, 0-35' 1 - AC Interlock Relay - 24VAC Coll 1 - Motorized Backdraft Dopper for A2 -D Housing OPTION (Qty. - Descr) 1 - Grease Box ti CI T 0' 111 CC K co N 0 3SIM 'd431 rL 7 n S n 4m7 C A5, 4., tl N Z AC my N P C 0 c.� N n 519-052'0-2V k 132014 lINf NVJ to 0 A N N O S N Z Cl O -ca ru 0.3 O f1 m 3 Z V 0 N 0 coN W o o 50 0 2 ,9 W B ❑ -i 50 r D m N E rm_ N v 1 A N O Z m N N m n73 m A zm r cm OZ k CO cc, B 130014 LINO NVJ NOIsVNYodnrr rri 0 O 40 40 YO o S o o s N W y 0' D Pm NC vy N Z m o cDi HStl1dSN3VB ,A1N0 SNOI1dO 0 2 | xoa 3sv3a9 1 "mv84:m'm1unu`ur ATy ,6Nmnyc,EmrFNn4awNtl c°nmSZ ?.1 :::Ifrttli5j'r;77,1ii: RR `g€1M.:�z-in_Rr yAd N nnc:i 0 3Gm—•. i 1111:.:.,iie,29iA�g °°� I1";C iA < Gg,LmPmA A tl ea'�y��[yH m i‹m c zln1A..,N•, n P o :!' mH _ ti-�a? Z.'.tlp o C r2,NS SAb: C SUPPLY SIDE HEATER INFORMATION, R3/501D .SI HILA .LINA DIA dfl r" i ;p1 i P ga • O ft. E "mv84:m'm1unu`ur ATy ,6Nmnyc,EmrFNn4awNtl c°nmSZ ?.1 :::Ifrttli5j'r;77,1ii: RR `g€1M.:�z-in_Rr yAd N nnc:i 0 3Gm—•. i 1111:.:.,iie,29iA�g °°� I1";C iA < Gg,LmPmA A tl ea'�y��[yH m i‹m c zln1A..,N•, n P o :!' mH _ ti-�a? Z.'.tlp o C r2,NS SAb: C SUPPLY SIDE HEATER INFORMATION, R3/501D .SI HILA .LINA DIA dfl 1 C n L1O2/S2/T .7.1VU Approved as Noted Approved with NO Exception To Revise and Resubmit SIGNATURE Your Title ❑ ❑ ❑ CUSTOMER APPROVAL TO MANUFACTURE: 070ti'-' D ti0-010-Iticam'-' 7:1 cop -9 ncrmx-Jmo❑o07J77 --Icc on❑m❑mmz c❑rl mzwC-0 < zrz<D 7)drS� �Vl 3 M31-,3 f 0W1--10 mo C0ti3>tiDZ0 Wm 0R) F-1 Z m Z o -I m rU m So(t) 3>01'C CH' -'do td m C --1 C TI 7J -1 1=3O C -1 m -Ifo Cr Do(' -2 „,t nocuccocDm(/) m7) zmri 73. T1'--1r•rlrFri m'D m i{Jr'lDr'lT)D 1 m _r. S(/l (�C�(�Mr�t�(� orlS ❑Nrr1~�d�on7 I-4 13, - 0 Z m co --I n 0Z NM (40(41-E D �C_ ❑tii� �ti'''DHm I, c: D70 Z ED Z❑ti D Z S tJ D C ❑ mmZ r�p3�D�3(��D� mom3z❑N�TJ (/) (SCS z)C-I ._.0-1-11-,(4-I D m C n D m 3> z1 -4Z ❑ '21-0ZSI-rH <�(i)(� Zr�D� MC,-, rn rI❑-1 (4Ctd<'-'Ztdrm 70 2! E m ti C71 3> rr� ao0a2J��d<d❑'H'it S-03 0S3 - cm -I 1--4 '--1❑Z7n S�JC0D C td7J,,S 0 __I j Zm� m�0Z �om❑r'l (Dtd -IZrQ WD DC') car �S-I,, r, CD a -< D ❑ Z D Z Z S C -I - I 0 3 K) r 3 M ❑-<D p J7Jtd .Cl❑3 ti m td UI C .--, Z (/) r td (4 --IP C Z7J Vi D E ITI Z) 0 TI 0 M --I 3- x P1 -1 0 D 3 -0 C3-I0D F- --I F- ED atd S r -1nfl rtyrrim 3' S D (/) ❑ m r1 ❑ r D❑7j mzc' tiro a d D ,. ti ] D d X £ C -I oa- Z(/)Zm a CIM MEIN.Js. ❑ m 70 Tit�-9-< 70N,ciN 0 I- R) 1 W7:1 Fo ,- o o N N 07JI--' Dwz❑ - (/) - I ` ( a Z '24179/1 _1 m m n r m r w d z N R) 0 m • Ti Exhaust Fan Wiring JOB 2899924 - Tukwllla Strelvor Hood DRAWING NUMBER EXH2899924-1 SHIP DATE 1/25/2017 MODEL NCA16FA -s 06 I__ __I GR SW -01 23 Installed Options Component Identlflcatlor Lei Description Location MT -01 Fan Motor C20 SW -01 Main disconnect switch L20 MOTOR INFO EXHAUST 2HP-208V-3P-6.1FLA R A NFIRMAT IN MOO OTOR/CTRL MOP, 15A NOTES - — — - DENOTES FIELD WIRING DENOTES INTERNAL WIRING WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY OR - ORANGE PR - PURPLE RD - RED PK - PINK WH - WHITE C Direct Fired Heater Wiring JOB 2899924 - Tukwllla Strelvor Hood DRAWING NUMBER DF2899924-2 SHIP DATE 1/25/2017 MODEL A2 -D.250 -G15 [ATTENTION ELECTRICIANI DROP FOR DISCONNECT CONNECTION WIRE TO a- -Y11®D3 � NO IS FACTORY SUPPLIED ILIA AND IL1B RE -DV -1 CONNECT POWER TO THE DROP IN DCV o---� (D3&D7 IN RD EMSPLUS) S_V-01 BK _ 6 'WD<DCV SF1 4 a g GR --J 3 4 Bl CB -01 BE --o BK 10 �! MT -01 MOCP = 10 AMPS FOR CONTROL WIRING o -- WH (DCV Ni) MT -02 (LF120-S) BK _ 2/11 WH 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 BK PC S-02 C OR RE -10 -1 C -1C1 RD OR TS -0 ®BL 1D114" o--e¢ct KYOB--0 24VAC Coll - Siggnal From Condenser 'Loll For CaoUng Interlock' TS -02 10281 C NC K (LINE 4) 70 0R 1014 60 RD 20 WH 3 0 101561GY GY 115 VH WH TR -02 BR 1241 BL 40B- 50 BR 17 Sc3 -B S1 o A� _ bG FSC -01 FR -01 VA -01 TR -03 HL1Ly SPARKS PLUG H BR 115 WH YW 24 TR -04 BL VA -02 2 3 4 5 6 7 8 MA -01 0 0 o a o 0 0 oloRD 02o13K 030 TS -05 L0uIRFISTART BL LLII EERR YW VA -03 R Installed OotIong Motorized Back Draft Damper Discharge Temp. Control DCV Wiring 24V AC Interlock Relay omoonent Identlfl atlott CB -01 rcult bree er (2anp) FR -01 Flame rod FSC -01 Flreye FSC [160 [11-140 MA -01 Modulating amplifier [190 MT -01 Supply motor [20 MT -02 Damper motor [50 PS -01 Low Airflow Switch [90 PS -02 High Airflow Switch [90 RE -DV DCV Relay [10[50 RE -10 AC Interlock Relay [100E170 SW -01 Main disconnect switch [20 SW -03 Dopper end limit switch [40 77R Power transforner(200v1pp TR15 'o tronsf rner(20va)C120 TR -03 Ign� lap trans owner [140 TR -04 ower tronsforner(20vo) [170 TS -02 HI temp limit switch TS -03 Intake00 Air Sensor ❑ 1100 TS -05 Discharge Air Sensor [210 VA -01 Pilot gas valve [130 VA -02 Main gas valve [180 VA -03 Modulating gas valve [200 MOTOR INFO SUPPLY 31-IP-208V-3P-9.5FLA MOTOR CC1 CUITCMC •AL ZNl .9AMATION CONTROL CIRCUIT MCA, 2.0A MOTOR CIRCUIT MOP, 20A CONTROL CIRCUIT MOP, 15A NOTES - — — - DENOTES FIELD WIRING DENOTES INTERNAL WIRING 11+ TERMINALS S4 AND S6 USED ON NF & AF SERIES ACTUATORS ■o. TERMINAL 11 PROVIDES COOLING CONNECTION =KU mu VIRE rni ryg max RELAY BK -BLACK YV - YELLOW RD - RED 10 BL -BLUE GR - GREEN VH - WHITE BR - BROWN GY - GRAY Pl( - Pgp( OR - ORANGE PR - PURPLE 4 c 01 6 3 7 5 C Installation Wiring JOB 2899924 - Tukwllla Strelvor Hood DRAWING NUMBER RP2899924-2 SHIP DATE 1/25/2017 MODEL A2 -D.250 -G15 120 V 1 PH, Disconnect Switch Gal -flex conduit (In unit) Factory wiring Customer GR supplied wiring 240 V 1 PH, Disconnect Switch Gal -flex conduit (in unit) BK (RD Factory wiring Customer GR supplied wiring 208/460/600 V 3 PH, Disconnect Switch Gal -flex conduit (in unit) Factory wiring Customer GR\ supplied wiring Installed Options DCV Connections POWER FROM DEDICATED BREAKER See above details, D3 IN HEATER TO IL1A IN DCV D7 IN HEATER TO IL1B IN DCV Power Connection WIRE TO ®\ DCV NOTES WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY OR - ORANGE PR - PURPLE RD - RED PK - PINK WH - WHITE gP 1 s 1 1 1 n 1 1 8 8 8 8 8 8 1 4 0 0 � o 0 xoa SS uI }unoW 11OA 1 TTTI-A317 # 30VNJVd 4=4 i. D i z a� o L 7 N `« N w x P r O J h C 2 ti Z N A3Q }JouS N L 2 X v L v m W W N N m N W 0 r H N r D U311021 NO3 SNVJ i 18 4 t G l: a 8 Y i S gi 4E a I i a lifffilliffillfilMi 8 8 4 4 P P 6 g 4 4 P 6 6 g A 4 8 6 6 g 8 6 8 6 6 9 6 gP 1 s 1 1 1 n 1 1 8 8 8 8 8 8 1 4 0 0 � o 0 xoa SS uI }unoW 11OA 1 TTTI-A317 # 30VNJVd 4=4 i. D i z a� o L 7 N `« N w x P r O J h C 2 ti Z N A3Q }JouS N L 2 X v L v m W W N N m N W 0 r H N r D U311021 NO3 SNVJ TYPICAL HOOD CONTROL PANEL INSTALLATION Demand Control Ventilation Hood Control Panel Specifications. - Controls shag be listed by ETL (UL 508A) and shop comply with denond ventilation system turndown requirements outlined In IECC 4032.8 (2015). - The control enclosure shall be NEMA 1 rated and listed for Instollotion Inside of the exhoust hood utility cobinet. The control enclosure may be constructed of stainless steel or pointed Steel. - Temperature probe(s) locoted In the exhaust duct riser(s) shalt be constructed of stainless steel. - A digital controller shell be provided to activate the hood exhoust fans dynamically based on a fixed differentlol between the ambient and duct tenperatures sensors. This function shop meet the requirements of IMC 507.2.1.1 - A digital controller shall provide odJustable hysteresis settings to prevent cycling of the fans after the cooking appliances have been turned off and/or the heat In the exhaust system Is reduced. - A dlgitol controller shall provide an odJustable minima,, fan run -tine setting to prevent fan cycling. - Vorloble Frequency Drives (VFDs) shell be provided for fans as required. The digital controller shall modulote the VFDs between a minimum setpoint and o naxlnun setpoint on demand. The duct tenperoture sensor input(s) to the digital controller shall be used to colculote the speed reference signal. - The VFD speed range of operation shall be from 00, to 1000 for the system, with the actual minimum speed set os required to meet minimum vent0otlon requirements. An Interpol olgorithm to the digital controller shop nodulate supply fan VFD speed proportional to all exhoust fans that ore located In the sone fon group as the supply fan. The system shall operate N PREP MODE during light cooking loud or COOL DOWN MODE when sufficient heat r nein underneath the hood system after cooking operations have conpleted. Operotlon during either of these periods will disable the supply fans and provide on exhoust fon speed that Is equal to the ninimun ventilation requirement. A dlgitol controller shall disable the supply fon(s), activate the exhaust fon(s), octivote the appliance shunt trip, and disable an electric gas valve autonoticolly when fire condition Is detected on a covered hood, A digital controller shall allow for external BMS fan control no Dry Contact (externo) control shell not override fon operation logic as required by code). An LCD Interface shall be provided with the following features. a. On/Off push button fan 1 light switch activation b. Integrated gas valve reset for electroNc gas valves (no reset relay required) c. VFD Fault display with audible 1 visual alarm notification d. Duct tenperoture sensor follure detection with audible 1 visual alarm notification e, MIs -wired duct temperature sensor detection with audible 1 visual Worn notification f. A single low voltoge Cat -5 RJ45 wiring connection 0, An energy savings Indicator that utilizes ,,ensured kVh from the VFDs Sequence of Operations. The hood control panel is capable of operating b one or more of the fo0owing states of any given time. - Automatlri The system operates based on the differential between room temperature and the tenperoture at the hood cavity or exhaust duct collar. Fans activate at a configuroble temperature differentlol threshold. Depending on the Job configuration each fan zone con be configured as stotic or dynanic. These terms refer to whether a vorloble motor (such as EC Motors or VFD driven motors) nodulate with temperature. If the panel is equipped with vorloble speed Eons and the zone Is defined os 'dynamic', these will modulote within a user -defined range based on the temperature differential. Panels equipped with voriable speed fans and a fan zone defined as 'static', fans will run at a set speed calculated for the drive. Denond control ventilation systems ore capable of noduloting exhaust and make up air fon speeds per the requirements outlined In IECC 403.2.8. - fffipugli The system operates based on human Input from an 1011. - $rhedule' A weekly schedule can be set to run fens for a specified period throughout the day. There are three occupied tines per day to allow for the user to set up a time that Is suitable to their needs. Any time that Is within the defined occupied time, the system will run of modulation node and follow the fan procedure olgorlthm based on temperature during this tine, During unoccupied time, the system w01 hove on extra offset to prevent unintended activation of the system during a time where the system is not being occupied. Ether. The system operates based on the Input From an external source (DDC, 8140 or hard -wired Interlock) JOB Tukwitta Streivor Hood LOCATION SEATTLE, WA, DATE 1/25/2017 ✓OB # 2899924 D/YC # 9 DRARrN BYJDC-85 REV SCALE 1/4' = 1'-0' / 1 :1 NI sI -1 NI .1 .1 -1 .1 a1 .1 m1 -I -1 .1 -I mI -1 -1 -I -1 -1 -I 1A< dm Ac A 2°7'Z'., A o<CiE r ZA 3E m m Hw y N 73xo 03 <r oC E H °o mom 3 y w y r nxomr n Z _ r' naA p CO m rO V0 < A v ora m G .m m 21T< v wAr isi D Nom a< A m a x A m V t z Z r to (*1 p COZ 0 �1/4Dn • o DL.21m — 0'-'on..14-u I( TTT TTT —a1�= ❑ r r70 0 13 VI Z A C m y A X m -'r zn oZ Pco =A 1477 r7 XI in H W vnz.-zoo- moyaao xo<^Ao mcmZ..r cI AZy-ZiD -ot+0crin r AO?<0O rnA Edi 1 1 1 1 1 1 1 1 1 1 13-I ,,55 tf; O xi <D= Ib 20 yr I Or n cr; 1 r I�' y�� ya 1 i �c�"� h mnC In Y' N< 5o D < noy I I r A., I r l 1 1 Z 11 In -1nv) .e Z.a I ny I\yI�-i� m r m Za �(u�1��� N o N < cci $ n x 2 3 rzi 1 N o < D S ("/ x ni) Z 3 f2'1 1 a" co or Zr mx ��� wm A a -or,',", =m W Axi rN nu �a �° v-0 h p m Z= r h N� ❑ =m ('•� mr0 ❑ j1) 211'. mx� A y.C.y i000a■ 2z 11 1 4 o o~ o Ao Dh z�,.„ yy ydi ciK v m o 5"' ,:,o L-71 -ooe �+ 54 Z FI 'A if m yn 1 I z e I I #1c 1 1 R N y 1 I I m z P D 7 Z ' N A �, oC Q Z nlmr r r Z 2 A �, IZ1 C'-I r r Rl II'1 £ m 6, I€ = A H2 xi ;P ❑ C 3 r 3 D 0 Z > r Z �� Illllliii^ N yIJ_f}� _ !C _ Illlllbbb..11lllllll� p o\ p p' o\ o\ y 1 N m A.J_ Iq I 0\N y o- o\ m o\u D y I 1 1 N� NP� HH� oFt 0 r z 9 r Z m r P m d n P� P3� r N < r n<Az y S -nj C'm"D A K(�^® m o A Z m� mm y m A DmD r z D O O 2 Ar . 0 N .oL i o D Z m ri1 Z A y m SL z 0 O y Z �� 99 aE m 1- OOC d m z 0 O D Z r n Do E o tl O S� D 2 xy 0rn. Z yo r N Cl O m IA z y a Z r i'+l A_ N N myy D3D NC❑ Am OL y LHO y SS z y y y z O V Z H r CONTROL F Res CONTROL PANEL ammoaan 2rmcAAAv vi DD r mND - �2 y. ZI..5;30CEm n'1, y Cum - jp mc m y N% £1 A O r'1 CS .pm= 0.2 A S O m 0E ZCA D r m n E D •j m VI na D ti N r r nn EE O" m m .-.0 rAi D 7 Z 1- <NZn A m r ti C C d z m; D.yiC'rmy Cyu77 Orny n Z Amr yn O D O..m ry y z r 3ZnytZ�u yy b E"ry2Z y rz/r N rmC COS�NrA ?Z n yZm AS 3 rrn ,-Ac .xr Z C '-1 A D r x O m y A ;O N H c c m -i 10 O NryKr n 73 r O mmoo y •2.1 nD70E mA N Hmzz C O 0403.2 -i�+o 0 mg PZ�Z 2 C VZ1 Lp~m c. m A 8 y S O O n C C N Z 2 ArA Qt. ',11: Ag r'1 O C r•l=. r f'1 C �1 A p m .[I 4• n m r C K n A y y S r o Ax2p y S C i m O S L m 1 A b0 m O X y n Z Z y Z - ti O Z Z m n ti O Z 1'9 S N y n A C Do N A A^ K u y0 O SO ER z3.;=-,. A? so 3r? m< Gl I�1 nv y p L r eF 0 (t) D0 r0 n n m ' (/1 Z. r. N N O ..• V RZSmpi�n K nO m tiCrCIIAy ZN O 3 C mry 0y m SO mlz Iz y y n n O O P 0�=1 0r'1-� y y p dC m Z n Z E D K r n JO D y y .y. Z 1 g Z =town O A= d m z r K CD'1 m x m C _ r 1 1 y C r., n❑ 7- 3 ••< n. _ 1 -I D r 1 I 1 I CJI nu A g Z 1 y l-` N �A �A z O E --I s 0 o .'. r m .+ LJ r ymL T,L rn L_J LJ 1__I Li"w= y i -100 2141 = rn >CRIPTI❑N d Control Ventl ate based on du for field Install et. OF ❑PERATI❑NI rtIon, r/ control for 1 Ex doe ? 1 i m myo=<d nz� xrD sit z a A 1m cz D m c1 r- O 1111 ;�^iar ra .. oP.P. mi ' C << ov c .74 1;1 c o 6 vy o,_o - 0 m Z Z <r yn p o n o I- z a ZC r ikr', w tenperoture. INVERTER otIon.Verlfy distance bet. l `r,E‘...2 Oro . yry V1Dr n ZE < Dy 1 mx N -r A 1 ZO C mx Z bi cnx D Z 0 rnvC ri C177 vm :5.2, toy. Oi< Ear 2r7 A-im X7177 4 Z COr DC rz_ Pit' E rm'IZJO mm rTal-i vco �mm rn 5r1' ZW Hy �n Ste? Z Z r r"" rn Cnw c3D Z3A Zm c n voz r Koca-r j3N 2rE 2 z oor x x 2-p; D D zx m K nK nO O -v I -0 3 m 0 m o 1Z 12 1Z 1Z hauF. ...act Fon, 1 Supply FuExhaust on h DUTY THREE PHASE MOTOR REDUIREDI Roo een VFD and Motors additional cost CORI r 1111 Irl. 1 1 1 1 = y -4 I 1• o 0 9.2 ye L ..,==2..,==2rn rn ab.. . p m r^ o i5 / I c N +7 -i 00 A- C, (n 0 A� AA 0 0 Z Z r< p 00.0 Db -cox M< r) r'1 v-'-4 mcmm 2o -1S run) b 0 O ci HLL, STRUCTURAL CALCULATIONS Western Foods Hood 641 Industry Drive Tukwila, Washington FEBRUARY 3, 2017 PREPARED FOR: All Star HVAC 4223 338th Place SE Fall City, Washington 98024 PREPARED Moore Engineerin 21902 96th Aven Snohomish, Was REVIEWED FOR CODE COMPLIANCE APPROVED FEB 14 2011 Gr oty of Tukwila lILDING DIVISION Moore 1, Engineering Group Mr1Oazo RECEIVED CITY OF TUKWILA FEB 08 2017 PERMIT CENTER GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. 2. DESIGN LOADING CRI !F,RIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT .HOOD —1,149 POUNDS MUA — 915 POUNDS FAN — 228 POUNDS EARTHQUAKE S0s = 0.914 SITE CLASS D to E WIND 110 MPH, EXPOSURE 13 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPEC 1'ED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL .PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE .RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR. PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. FRAMING LUMBER SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (2x MEMBERS) JOISTS: (4x MEMBERS) HEM -FIR NO. 2 HEM -FIR NO. 1 Fb = 850 PSI, Fv = 150 PSI Fb = 975 PSI, Fv = 150 PSI 8. ENGINEERED LUMBER: EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT NUMBER OF THE MANUFACTURER, THE GRADE, THE NER OR ICC- ES CGES REPORT NUMBER, AND THE QUALITY CONTROL AGENCY. ALL MEMBERS SHALL BE MANUFACTURED WITH AN APPROVED ADHESIVE. BEAMS: M.ICROLLAM LUMBER (LVL): Fb = 2,600 PSI, E = 2,000 KSI, Fv = 285 PSI 't`--1 cD co c5 a 9. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG - TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C-2015. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 10. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITU 1E (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 11. WOOD SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.6.1.. 12. BOLTS SHALL CONFORM TO ASTM A-307. 13. CONNECT THE EXHAUST FAN TO THE WOOD ROOF STRUCTURE WITH (3) #12 x 3" LONG WOOD SCREWS ON EACH SIDE OF THE FAN PARALLEL TO THE SUPPORTING SUB -PURLINS BELOW. PLACE ONE SCREW AT 4" FROM EACH CORNER AND THE REMAINING SCREW EQUALLY SAPCED BETWEEN THE CORNERS. 14. CONNECT THE METAL CURB FOR THE MAKE-UP AIR UNIT TO THE WOOD ROOF STRUCTURE WITH A MINIMUM OF (4) #12 x 3" LONG WOOD SCREWS ALONG THE LENGTH OF THE CURB. PLACE ONE SCREW AT 4" FROM. EACH CORNER OF THE UNIT AND THE REMAINING SCREWS EQUALLY SPACED BETWEEN THE CORNERS. 15. CONNECT THE MAKE-UP AIR UNIT TO THE METAL CURB WITH A MINIMUM OF (4) #10 SHEET METAL SCREWS ALONG THE LENGTH OF THE UNIT AND (2) #10 SHEET METAL SCREWS AT EACH END. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER OF THE UNIT AND THE REMAINING SCREWS EQUALLY SPACED BETWEEN THE CORNERS. 16. SUPPORT THE BACK OF THE HOOD TO THE METAL STUD WALL WITH #12 SHEET METAL SCREWS AT 16" ON -CEN 1ER. 17. SUPPORT THE FRONT OF THE HOOD TO THE ROOF STRUCTURE AS INDICATED ON THE ATTACHED HANGER DETAIL. 18. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: TYPE OF MEMBER A. ANGLES B. THREADED RODS ASTM SPECIFICATION Fy A36 GRADE 5 36 KSI z ." 11 ' 3 • 8 . Moore Engineering Groupfl PROJECT": ENGR: ICOV DATE: SCALE: SHEET (E.,ye.co 3L eo '5 .. ti P 2 P'E rei ice`) F Moore Engineering Group PROJECT: co75 ENG R: Ad V DATE: i %.3 / i SCALE: SHEET PROJECT DESCRIPTION: The project consists of a new hood, make-up air unit, and exhaust fan. LOADS: LIVE 25 PSF DEAD Roofing and re -roof 4.0 1/2" plywood sheathing 1.5 2x4 @ 24" on -center 0.7 4x12 @ 8' on -center 1.4 Insulation 1.0 MEP 3.0 Ceiling & Lights 2.0 Total Dead 13.6 DEAD + LIVE WIND 110 mph, Exposure B SEISMIC 38.6 PSF Latitude 47.453 Longitude -122.249 Site Class D to E WA DNR SDS (D) = 0.963 S05 (E) = 0.866 SDS = 0.914 EQUIPMENT Weight (lbs.) Hood 1,149 Make-up Air 915 Exhaust Fan 228 Moore Engineering Group PROJECT: WESTERN FOODS HooD ENGR: KVVM DATE: 2/3/ 17 SCALE: SHEET 2/2/2017 Design Maps Summary Report USG Design Maps Summary Report User -Specified Input Report Title Western Foods Hood Fri February 3, 2017 01:01:24 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.453°N, 122.249°W Site Soil Classification Site Cass D -"Stiff Soil" Risk Category I/II/III USGS-Provided Output SS = 1.444 g Si = 0.538 g SH5 = 1.444 g SM1 = 0.806 g SpS = 0.963 g SD1 = 0.538 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.65 1.50 1.35 1.20 1.05 0 0.50 0.75 0.60 0.45 0.30 0.15 0.00 0.00 MCER Response Spectrum 0.20 0.40 0.60 0.90 1.00 1.20 1.40 Period, T (sec) 1.10 1.00 0.90 0.90 0.70 0 0.60 to 0.50 0.40 0.30 0.20 0.10 0.00 1.60 1.90 2.00 0.00 0.20 0.40 0.60 0.90 Design Response Spectrum 1.00 1.20 1.40 1.40 1.90 Period. T (sec) 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. httpJ/earthquake.usgs.gov/designmaps/us/summ ary.php?template=minimal&latitude=47.453&longitude=-122.249&siteclass=3&riskcategory=0&edition=ibc-20,.. 1/1 2/2/2017 Design Maps Summary Report usGs Design Maps Summary Report User -Specified Input Report Title Western Foods Hood Fn February 3, 2017 01:01:48 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.453°N, 122.249°W Site Soil Classification Site Class E - "Soft Clay Soil" Risk Category I/II/III USGS-Provided Output Ss = 1.444 g S1 = 0.538 g SMS = 1.300 g SM1 = 1.290 g Bps = 0.866 g SD1 = 0.860 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.43 1.30 1.17 1.04 0.91 C 0.79 lA 0.65 0.52 0.39 0.26 0.13 0.00 MCER Response Spectrum 0.00 0.20 0.40 0.50 0.90 1.00 1.20 Period. T (sec) 1.40 1.60 1.90 2.00 0.99 0.90 0.91 0.12 0.63 W 0.54 to 0.45 0.36 0.27 0.17 0.09 0.00 Design Response Spectrum 0.00 0.20 0.40 0.60 0.70 1.00 1.20 1.40 Period. T (sec) 1.60 1.90 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool Is not a substitute for technical subject -matter knowledge. 747 http://earthquake.usgs.gov/designmaps/us/sum mary.php?template=minimal&latitude=47.453&longitude=-122.249&siteciass=4&riskcategory=0&edition=ibc-20... 1/1 0 HOp ► ONS N0. 1 TAG Ik OPT10N OPTIONS ONLY' BACKSPLASH 12000' High X 216.00' Long 430 SS Vertical FAN INFORMATION — Job#2899924 FAN UNIT N01 TAG FAN UNPT MODEL 6 CFM ESP. RPM HP. BHP, 0 VOLT FLA(LDS) WEIGHT ONES 1 WEIGHT GP: NCA16FA 2973 1.000 1080 2.000 0.9550 3 208 6.1 187 12.7 MUA FAN INFORMATION — Job l(2899924 FAN. UNIT NO. TAG FAN UNIT MODEL i1 BLOWER HOUSING MIN CFM DESIGN CFM ESP. RPM H.P. DAP. q VOLT FLA WEIGHT GP: SONES BURNER EFFICIENCY(, 2 A2 -0250-G15 615-88 412-11.250 2000 2973 0.750 822 3.000 1,4920 3 208 9.5 239 14.6 92 FAN UNIT NO, TAG INPUT BTUs OUTPUT BTUs TEMP. RISE REQUIRED INPUT GAS PRESSURE GAS TYPE 2 1 - AC Interlock Relay - 24VAC Coil. 191952 176596 55 deg F 7 In. w,c. - 14 in, w,c. Natural FAN UNEP N0. TAG OPTION (Qty. - DescrJ 1 1 - Grease Box 2 1 - AC Interlock Relay - 24VAC Coil. 1 - Motorized Backeiroft Dopper For 62-11. Housing 1 - Low Fire Start 1 - Inlet Pressure Gouge, 0-35' 1 -.MoniFold Pressure Gauge, -5 to 15' we 1 - Extra Set of' Belts 1 - Separate 100V Wiring Package (Required and used only for DCV or Prewire with V200 - Throe 86ase only I - Size 2 Direct Fired Heater Low CFM Profile Package. Used on Heaters under 2500 cfn. FAN ACCESSORII FAN UNIT N0. T60 EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER VAIL MOUNT YES 2 YES CURB ASSEMBLIE'S G. WEIGHT 11E14 SIZE 1 1 2 1 1 41 LBS Curb 26500'V x 26.500'L x 20.000'H 1.00012.000 Pitch Vented Hinged 2 * 2 76 LHS Curb 31.000'W x 79.000', x 20.000'H 1,00012.000 Pitch Along Width. Right Insulated in:urtnh � JODTukwilla. Streivor Hood LOCATION SEATTLE, WA, DA79,' 1/25/2017 JOB # 2899924 DRe1ION .8YJDC-85 REY, SC,di.S' 3/8' = 1'-0' DWG' # 1 10/ OE W CU N ✓) F- WW vMwW *"D¢ Z a ci J 1- D ¢ WDJ M nJ O F �� CUAV' CL W D 1 cu J W >hhaw I w3D W J U p Q¢ Z Z r-, 0 • ZPW zw == �—'`r P a CL ¢F-a4U CLOWN : ' U J q z z W W 0¢ JDW W D✓)S Z WnJQJ -WUI- J S • ' DJ F - -J <c!,2I- Z N EJB Q W0L,_U Q LJ 1,2.-,i< n ci z D WF - O J (n Z .--, D In (=I I- (n q ZDD .. QQNW ¢?-w w1 _s xc)h- Z Z v i I 0; ill 4; fi lit !4t'jn 1 s F9 I! t} , , 1'111 111 g `i tum a 0 O 0 La m s_ )- 41 t- +nd O Y Q 3 (~ 0 Q CJ 1 N /1 a 3 t 0 uJ> 0 z 0. g 3 3 6 m m m 5. p. 1 i 44 r 5 1 , , 1,I ii ---1 , g ••• v IQ, ,i, - '' - , 1,,, I r,?:.,F. 101•I'' 53 %, 1 t3ig'' ' ; H.0.3:4 ;0_!,.,o. A I-- ! LEGAL DESCRIPTION_/ PARCEL NO. s 5 g 5 ' • 6 i ' I ..• 1 x Z --• < , • IIIIIII viii 311,11 •;1 5ill!ii -4,111 III 1 i , , 1 i ,. E. - 4..„1. ,-,•,', : , --,--' 'J.. '47 E.,- • .--- -. s ,: .. • , , ...,.-4-4 i_........__I ‘,.,1„ -1 • 11. 1 8 i, ..... 2 '-'!". I _11.1___.i7o1 —3-- i 2;1 ..L. iii l'n117-1 rr II I il ; 3 i a ti t 1 az S w5 1 , g g , - I rag ! g 1 S g - g 11 ; i gg - 1 . R9 . 4,143 gg a' p g 1 1 1! l',1 i 114115 guli J. 1 Iii 12 loi $1! 11 WW1 y g -?",1 74 gi a g la fg5 a mu b boa - !Pi ,,, I, i ilg g9 151 v.= 555 5-555 -i gi,g g . 511 p.5 E [ STREET MAP 'k *•.;:,...,r\ ' : -.- 1 — ......... i _ N i • - , ,,,„ ' ; 1 I '4, '', ', „ >.. , 1 i '' •'E._ i _ ;AP r-'-' i mnrg• t._: , • ;Ai r'i l'ipr- , IV F'• I Ek; . *Iii HZ gto s.4.- ,Lal,„,,,„„,. itni 0 i a qi 41 !=I . II . sr E i5 ip 6 r&thit ''l . gg itd g hfighg 4 -4. i< g5ffligsg7.801.5eggth-IggiiEE:g1E5L'AgElIgulenhil4o.the o 9 1 - 0 t t i L. .1 n 3 1 •1; I S• ,;:;• e i ! q i) / 8 h i i.i ,..., ;A, 5 4 ! 3250-7 ; ' • ,, pblEIR , 1 :1 iggoggAgERA - g kegl$,X.. .4 E i. '5Utan6H4he62s4s l•t;,g HPgg_...1 DEFINITIONS AND DIMENSIONS 1 1 g • I 4 4) t si lg g .. ,1 le gl 2 X, IN . il t 4 n b E IR l' ;1 W 4 ! !I 16 e , m / . § ?, 4 Id ,x il a as 2.1 0 a 4 E, ? 'r- 1 1 /1 1 5i! ," D t ,g. b 5 14 5 '- -°?! 4 i • - i . P AE •1 1 5 :5 ? 4 p 1 ! gr ;, )Ap!Z.. Pn i 4 ! - A'•' t4ggav.,, . tg: " r a - 1..iI1I-L1.":.).dM2.f1•1a,*,.-a--t;.Pg44, 4. R-.;- 4)151 5, yi.-gEgd P z t i ',m °X iA i t s 1.---.13i3 I ; iLlat', A !i !44.4 °YA3A. ,1ds6,.g•;i rEW!'3P5:-Is;W v, A' w g3= "- 2 g1 mm . , z "ag I I SYMBOLS RL04ri A-_ aI i .2 g 1 34 '. g,5, . g0oOqeW–d\ . - 5 f c, '-'2 a c!Iifi<'R l' g '' CT" x 1^100ZiOAT42711S*MMM , SSO6-0S6 SZ6):XVd 06°6,096 (Te6);BNOI id V..,'S>6 V01110161>i3All `C.,VO>1>IMVH AIII>I OSLZ Z , t = ON37730X3 t:10_4 DIVIAlaILLS,, Lu 0 I— 0 i : • ; -----711111111 , pil 0 Si413,LSAS 11114,3210A13aLLS Y.r4 l'Airi ev.1<ki<G71 g 'i •-•y,1‘) Jr kr. - sJr o fid' rbcs Ml a ✓` - -o 1c�' , S" _ 7.51,x3 316.c. (317: 10.E2 (f If 0 r 1/e0 '� Moore Engineering Group PROJECT: ENGR: 4\ DATE: 01,/ /17 SCALE: SHEET 4:=0O r r'=R;`_. C : !VI, 1 5 ( � ,4o wt LL)' 4 r lea d a' (E).\,44" wr 104 Moore Engineering Group PROJECT: 'c AFD) b ENGR: DATE: /1/17 SCALE: 174 SHEET (l�' �`�`f,� = 915-. 0,4 (2,'.7)`9:514(4i`�/,) 11cokfveCAL Co ,l yt.,e-, e Moore Engineering Group PROJECT: 1- 43 ENGR: /-1V LJ DATE: .,/Z / SCALE: SHEET PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0020 DATE: 02/08/17 PROJECT NAME: WESTERN FOODS SITE ADDRESS: 641 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: nw��Ia_ Building Division Public Works AM kW° 911 Fire Prevention wi Structural Planning Division ❑ ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 02/09/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/09/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: `Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 ALL STAR HEATING & A/C INC Home Espanol Contact. Safety & Health 16 Washington State Department of AP Labor & industries Claims & Insurance Page 1 of 2 Search L&I A -Z Index Workplace Rights ALL STAR HEATING & A/C INC Owner or tradesperson Principals CONVERSE, PATRICK NEAL, PRESIDENT Doing business as ALL STAR HEATING & A/C INC WA UBI No. 601 703 920 PO BOX 70 FALL CITY, WA 98024-007'0 425-222-7652 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. ALLSTHA044JK Effective — expiration 04/12/1996— 04/12/2017 Bond Great American Ins Co Bond account no. 2214136 Received by L&I 02/03/2014 Bond history Insurance Active. Meets current requirements. $12,000.00 Effective date 01/24/2014 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601703920&LIC=ALLSTHA044JK&SAW= 3/13/2017 ALL STAR HEATING & A/C INC Continental Western Ins Co Policy no. CWP6011429 $1,000,000.00 Received by L&I Effective date 01/13/2017 01/15/2014 Expiration date 01/15/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. Page 2 of 2 L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 933,780-00 Doing business as ALL STAR HEATING & AIR CONDITI Estimated workers reported Quarter 4 of Year 2016 "21 to 30 Workers" L&I account representative T1 / IDA HAYNES (360)902-5635 - Email: HAYN235@Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 07/01/2011 Inspection no. 314896119 Location 3131 Elliott Ave Seattle, WA 98121 Violations © Washington State. Dept, of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601703920&LIC=ALLSTHA044JK&SAW= 3/13/2017