Permit M17-0028 - BOILING POINT RESTAURANT - UNIT REPLACEMENT
BOILING POINT RESTAURANT 361 STRANDER BLVD MI 7-0028 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049064 Permit Number: 361 STRANDER BLVD Project Name: BOILING POINT RESTAURANT Issue Date: Permit Expires On: M17-0028 3/23/2017 9/19/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: REGENCY CENTERS LP PO BOX 790830 C/0 PROPERTY TAX DEPT, SAN ANTONIO, WA, 78279 PAUL JOSEPH 4426 221 PL NE , REDMOND, WA, 98053 PERFECT CLIMATE INC 4426 221ST PL NE, REDMOND, WA, 98053 PERFECI022D5 //I Phone: (425) 260-6955 Phone: (206) 977-7353 Expiration Date: 3/12/2018 DESCRIPTION OF WORK: REMOVE (2) EXISTING ROOFTOP UNITS AND REPLACE WITH (2) NEW UNITS ON EXISTING CURBS. INSTALL DUCTWORK FOR (2) UNITS. Valuation of Work: $32,500.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $637.24 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: i �� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per it and agree to the conditions attached to this permit. Signature: n -- Print Name: nil, 1 -3vSi:`0‘a Date: 3/23Ji 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) •15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 4 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to -be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 361 Strander Tenant Name: Boiling Point PROPERTY OWNER Name: Paul Joseph Name: Regency Cntr Address: 4426 221st PI NE Address: 321 Strander Blvd City: Redmond City: Tuk State: Wa Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Paul Joseph Address: 4426 221st PI NE Address: 4426 221st PI NE Phone: (206) 977-7353 Fax: (425) 836-3980 City: Redmond State: Wa Zip: 98053 Phone: (425) 260-6955 Fax: (425) 836-3980 mail: pclimate@aol.com King Co Assessor's Tax No.: 262304-9064 Suite Number: Floor: 1 New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Perfect Climate Inc Address: 4426 221st PI NE City: Redmond State: Wa Zip: 98053 Phone: (206) 977-7353 Fax: (425) 836-3980 Contr Reg No.: PERFECI022D5 Exp Date: 03/12/2018 Tukwila Business License No.: BUS0993391 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Remove (2) existing rooftop units and replace with (2) new units on existing curbs. Install ductwork for (2) units 32,500 Use: Residential: New ❑ Replacement ❑ Commercial: New 0 Replacement ❑ Fuer Type: ;Electric ❑ Gas Other: H:\Applications\rorm-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <1 OOk btu Residential, Nighttime Furnace >100k btu 14 Floor furnace 2 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heathefrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfin 2 Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 14 Evaporator cooler 2 Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 14 Thermostat 2 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor QtY 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER o1.4 THORIZED AGENT: Signature: Print Name: Paul Joseph Date: 02/23/2017 Day Telephone: (425) 260-6955 Mailing Address: 4426 221st PL NE Redmond Wa 98053 H:\Applications\Forms-Applications On Line12016 Applications'Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $637.24 M17-0028 Address: 361 STRANDER BLVD Apn: 2623049064 $637.24 MECHANICAL $612.73 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $457.03 PLAN CHECK FEE R000.322.102.00.00 0.00 $122.55 TECHNOLOGY FEE $24.51 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10973 R000.322.900.04.00 0.00 $24.51 $637.24 Date Paid: Thursday, March 02, 2017 Paid By: PERFECT CLIMATE INC Pay Method: CHECK 11338 Printed: Thursday, March 02, 2017 1:14 PM 1 of 1 Ci SYSTEMS z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 X17 -0c Proj t: Zti4 Pri/VT— Tyyp of Inspection: f "/ i Akiligit..- ArAi.L Address: 261wat,itot.PitAit Date Called: Special Instructions: • Date Wane : 3 `� - .m. Requester Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: /, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit !YU7- 002,6 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pygiect: 1 ^1U #tJ ec)W Type of Inspection: M7/ t/4,, /J14L �' J i '. Address: 36 i ' " AJ b Date Called: Special Instructions: A Jo: Date Wante '. 642/ 7 , p.m. Reque l— Viti Phone No: 206- 977 - 7 3 DApproved per applicable codes. Corrections required prior to approval. COMMENTS: CA-Aicki,e1_032(�r.ng2 ) S3' Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Mild X28 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proect: 10AJ6• 7 Ty a of Inspection: -1, ai ? C41 - Address: ! /I & Date Called: Special Instructions: Date Wanted i C •a. Requeste . Phone No: 1471 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector:Ami Datee) 2/1 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with'permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project.--> jilvd•V /-1/71/. Sprinklers: Type of I spection: 7,91, Address: Suite #: 361 ,moi i i' ,,,,"— Contact Person: Special Instructions: Occupancy Type:. Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: / Acc Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type:. Inspector: fiij `r- � Date: %31/ Hrs.: / . c� $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from.. the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /i1/9 — CeVg / - F -CJS - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 72X//(m Por `t f""' on: Type of Inspe3ut- 4 Address: .Suite #: Al 5 t,,�ev 81'8 Contact Person: po Special Instructions: Permits: Phone No.: 'Approved per applicable codes. Corrections required prior to approval. COMMENTS: F/'7- c;74--(� ( Z%7.IYL SinAlf 4:3 - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: ki/ 6 fl Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address tAttn: Company Name: `Address: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Job : t g‘i4 Poi.. 1 - tee: 6 -13-1-2 eon RECEIVED CITY OF TUKWILA JUN 232017 PERMIT CENTER VuoOLS _�•��.+ s. v- K.°� r _c -tg y k`��"` x' `✓� -t - a•:.. - .f '- sex" -s �r "35.� ` �'"'i-.. "may c }`+ Tt��".._ ' `5 ^iy, _ 4� 'GoVV + : - ' - � _ F -� r�a' -+'6'" tea..._ - ' 'r'} -.5. '#"ui'�C` a � .� � -, $�" �..'�.�. �'..%� ; �,. - �`' a r3F* "'.c toms ��� 60a� s v 611 6)30 . Ivo Go i.? 600 i0 _! 610 Sf30 5-0 -'510 00 6oD lou . cap ► 67v - 67o . 57 0 Soo ' S>) , .306 1 Soo oo ! 9 x 90o 5o a J to — �{ Ud yav 350 11 35A Stip f J $y i• I Zo u vv ik v v `? o . -;O) > 2,5 1 o - it u '12.:, fro _ ; 2a 10 11if-----1--- ii _ k — - r......7.____ I �, k r.-- - i _1- k 1 'i s I .0 1 ) 1.2. 850 11 S? '7 '' T_�v - _3 v- -' bov 1 2 11 Zv 1 id> -1 13 0 I = 6 . 0 _ 1 3 Zo 7 20c�00 -So I 1 ?fro z � j •_ v-. vo 2- f 0 R0 IA) C I t o 'iii 29) lk vv o v I -iso - 150 4 2 11111 6 1 6 .Sv 5v - 0. Sv _ 56 Sv 1 6 } 50 Sv i 5v o f 0 v t �, - • rs ! Z%O+, k 2- t V ' 2�4 a) 07 it h_ s 1 << Fq tis 1 - -- ; 0 ?s0 II Z - Su `, 6.0__ _ 4.00 , 72 r t 7 VuoOLS February 14, 2017 To: City of Tukwila Cc: Wilson — Core Construction Q&H Job # 17-100 Subject: Boiling Point Restaurant — HVAC Unit Replacement Project Address: 361 Strander BLVD, Tukwila, WA 98188 To whom it may concern, Existing Condition: The tenant space noted above is a (1) -story restaurant with CMU exterior walls and wood framed roof. The roof consist of 24" and 30" deep TJI joists, that are spaced at roughly 48" o.c., spanning East to West. A 6-3/4x31-1/2 glulam beam is located at the mid -point of the tenant space spanning North to South supporting the roof joists. There are currently two 4.5 ton capacity HVAC units located on the roof just above the glulam beam (see sheet S-1 for exact locations) and each unit weighs roughly 470 pounds. Proposed: The owner is proposing to replace the existing HVAC units with two 7.5 ton capacity units. Each unit weighs 945 pounds (see attached spec sheet). The existing wood curbs on the roof currently supporting the HVAC units will remain and the new units will attach to the existing wood curbs. There will be a total of 475 pounds of additional load shared by four existing roof joists under the wood curb, which means each joist will carry additionally 119 pounds at each unit. Conclusion: Based on the fact that the TJI joists are 24" and 30" deep and by our engineering judgment, the existing roof joists are sufficient for carrying the above mentioned added loads. However, the 'o supporting the new HVAC units shall be reinforced by adding web stiffeners wood curb, see detail 2/S-1. New 2 x 6 members shall also be added around th detail 1/S-1. Please feel free to call me at 206-371-2770 should you have any questions or co Sincerely, Qing Hua Huang, PE EXPIRES 5-31-1 roo C = • i irlteDiFteiR APPROVED MAR 14 2011 cemsCity of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA t4►R 02 2011 PERMIT CENTER M 002$ G F §§ T . | . — . ƒ NIL~ 1g /\ ( 2 . � UNG « RESTAURANT _ sr__ _« m_LA. WA .\ \ |� Gk | «! `® |'' y Ute§ i ■/ 4 ®Z) . . ! . § 4 P q m-©•4,0. «— , n®©®4,0 0.C. — . . . . I III" . . , |L. a; ! x q I Pt, J 2 _ OP 1 1k§ r\ q i 2|; 2 I CURD SUPPORT SECTION DETAIL `/ ¥ ` 2x 12 wee 9TrrENER BOTH I' MIIl BIDS, TIENT AGAINST TOP PIANGE DIRECTLY UNDER MVAC CURD W/ (10) I Gd (3.2•) NAILS STAGGERED • MIN. ƒ NIL~ 1g /\ ( 2 . � UNG « RESTAURANT _ sr__ _« m_LA. WA .\ \ .. Id Va MBAR} i. . s2/ 2■ Z. • 4-4.— MIN. ,/-2X I8 WEB STIPPENER DOM SIDES. °/ T16N1 AGAINST TOP PURR DIRECTLY UNDER MVAC CURB W/ (12) 1 Gd (J.Sy • e NABS STAGGERED. MIN. gk ggE \2 CI ; ; ! , gi q �. 1II020 ONIDYOdNtra / ! \ % % )§; _ m § CT:1 � UNG « RESTAURANT _ sr__ _« m_LA. WA S AVE«RU Ha 8 Project:-Untitled2 Prepared By: 7.5T GasEle-460v 01/10/2017 07:44AM 7.5T GasEIe-460v Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet REVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 02 2017 PERMIT CENTER Mt7OOZ8 Packaged Rooftop Builder 1.45 Page 1 of 9 Project—Untiiled2 Prepared By: Unit Report For 7.5T GasEle-460v 01/10/2017 07:44AM Unit Parameters Unit Model- 48TC13D08A2A6■0AOG0 Unit Size- 08 (7.5 Tons) Volts -Phase -Hertz 460-3-60 Heating Type- Gas Duct Cfg:.__-___..-_.-.Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size- 112 Condensate Drain Line Size- 3/4 Return Air Filter Type* Throwaway Return Air Filter Quantity- 4 Return Air Filter Size- 16 x 20 x 2 Unit Configuration Medium Static Option (Belt Drive) AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging 2 -Speed indoor fan motor controlled by VFD Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Chnenskn' Ts (ft. in.) & Weight (Ib.) Unit Length- T 4,125" Unit Width:. .... -- - - - 4' 11.5" UnitHe.__-eight 3' 5.25" • ~�f Total Operating Weight..-__ 945 Ib '•' Weights and Dimensions are app ate. Weight does not indude unit packaging. Approxi ate dimensions are provided primanly for shipping pure es. For exact dimensions and weights, refer to app riate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information • Part Number - Description Quantity 48TCDD08A2A6-OAOG0 Rooftop Unit 2 Base Unit Medium Static Option (Belt Drive) None 2 Speed Fan Controller (VFD) . Accessories CRECOMZR069A00 LOW LEAK - Vertical EconoMi$er 2 Packaged Rooftop Builder 1.46 Page 2 of 9 v cQ CD 0 0 0 0 0 w 0 CD CT ICD CD C.) 0 CO Co 0 58600SW187 rn 7 O O 0 0 IFR rrl if krg EiU 1.0 22 IV80 31VSN30800 id AlddflS 83MOd YI0 [691 S3ZIS NOIID3NNOD S 25 7'8 v -o mo 76. m 0 CL CO c '� CD 0. N Certified Drawing for 7.5T GasEle-460v SUBMITTAL IMicroMetl FORM NO. 18390-2D 111/5/2015 Submitted To: Company: Job Name: Notes: No Units Selected Part Number: ECD -S RT34TA-D2D H-0 FEATURES: • For single, 2, or 3 speed indoor fan units, as listed above. • External gear driven dampers, eliminate slippage associated with standard linkage. • Designed specifically for down discharge applications. Easy to install. Easy to service. • Factory assembled rainhood with aluminum water entrainment - filters in the outside portion of the hood. • Uses filter access door shipped with HVAC unit. • )iincied filter access door is ordered seoerately. Part number " ECD-SRT3TA-HDOOR " for Chassis units. Part number " ECD-SRT4TA-HDOOR " for Chassis 4 units. • Rainhoods are sloped for water run-off. • Jade W7220 economizer control, Certified FDD Product California Title 24, Part 6 HJW10 California and ASHRAE Code Compliant Direct Coupled actuator Economizer 60 lbs., Hood 28 lbs., Total 88 lbs. Logic and mounting p ate. Field installed in control compartment. Mixed air sensor. PL6 Harness Field installed in mixed air section. External, gear driven dampers Outside air sensor Economizers meet Title 24, 2013, Prescriptive Section 140.4(e)4(A, B, C, and H), D, E, F, and G when supplied with controls, and ASHRAE Standard 90.1-2010, Table 6.4.3.4.4 requirements. 5 year parts and componenets warranty. Damper life cycle testing and leakage. Relief. Sensor setpoint, reliability, calibration, and high limit. Economizers meet Title 24, 2013, Mandatory Section 120.2 Economizer fault and detection diagnostic requirements, when supplied with controls.. 22.2" Stainless steel blade side seal on return and outside air blades. Side View I► -020H Series Honeywell communicating actuator w/ adjustable dry bulb controls. -D2EH Honeywell communicating actuator w/ enthalpy controls. -D2XH Honeywell communicating actuator w/ differential adjustable dry bulb controls. -02ZH Honeywell communicating actuator w/ differentiae enthalpy controls. THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETL'S WRITTEN CONSENT MicroMetI Corporation... Indianapolis Indiana — 1-800-662-4822, Sparks Nevada — 1-800-884-4662, Longview Texas — 1-903-248-4800 • 9t7'1, JaPIin8 dojooa pe6e)oed CO CO CD A 0 CO CO 74 -rTI 58600SW18V 0 • T. 0 rrl 8 R 1313 m o N 0 m r n 03 C (D 0 Project:—Untitled2 Prepared By: Certified Drawing for 7.5T GasEle-460v 01/10/2017 07:44AM Packaged Rooftop Builder 1.45 Page 5 of 9 • Service ', Clearance C4^_247 3,113 LOCATION DIMENSION CONDITION A 48 -In (1219 mm) • Unit disconnect Is mounted on panel 364n (914 mm) • If dlmenslon-8 Is 12 -In (305 mm) 18 -In (457 mm) • No disconnect, convenience outlet option • Recommended service clearance (use electric screwdriver) 12 -In (305 mm) • Minimum clearance (use manual ratchet screwdriver) 6 36-10 (914 mm) • Unit has economizer 12 -In (305 mm) • If dimension -A Is 36 -in (914 mm) Special • Check for sources of flue products within 10 -ft of unit fresh air Intake hood C 36 -In (914 mm) • Side condensate drain Is used 18 -In (457 mm) • Minimum clearance D 48 -in (1219 mm) • No flue discharge accessory installed, surface Is combustible material 42 -in (1057 mm) • Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) 36 -in (914 mm) • Surface behind servicer is electrically non-conductive (e.g., wood, fiberglass) Special • Check for adjacent units or building fresh air Intakes within 1D -ft of this unit's flue outlet NOTE: Unit not designed to have overhead obstruction. Contact Application Engineering for guidance on any appll ation planning overhead obstruction or vertical clearances. masa Packaged Rooftop Builder 1.45 Page 5 of 9 • Project:-Untitled2 Prepared By: Performance Summary For 7.5T GasEle-460v 01/10/2017 07:44AM Part Number:48TCDDO8A2A6-0A0G0 ARI EER. 11.00 IEER. 12.8 Base Unit Dimensions Unit Length. 88.1 in Unit Width. 59.5 in Unit Height 41.3 in Operating Weight Base Unit Weight 835 Ib Medium Static Option (Belt Drive)- 15 Ib 2 Speed Fan Controller (VFD). 20 Ib Accessories LOW LEAK - Vertical EconoMi$er 75 Ib Total Operating Weight 945 Ib Unit Unit Voltage -Phase -Hertz. 460-3-60 Air Discharge. Vertical Fan Drive Type' Belt Actual Airflow. 3000 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU/Ib Evaporator Leaving Air DB. 58.7 F Evaporator Leaving Air WB. 57.6 F Evaporator Leaving Air Enthalpy 24.76 BTU/Ib Gross Cooling Capacity. 90.10 MBH Gross Sensible Capacity- 68.90 MBH Compressor Power Input 6.40 kW Coil Bypass Factor 0.092 Heating Performance Heating Airflow. 3000 CFM Entering Air Temp- 70.0 F Leaving Air Temp. 101.8 F Gas Heating Input Capacity. 125.0 MBH Gas Heating Output Capacity. 103.0 MBH Temperature Rise. 31.8 F Thermal Efficiency (%). 82.0 Supply Fan External Static Pressure- 0.60 in wg Options / Accessories Static Pressure Economizer 0.11 in wg Total Application Static (ESP + Unit Opts/Acc.). 0.71 in wg Fan RPM. 792 Fan Power 1.80 BHP NOTE. Selected IFM RPM Range: 733 - 949 Electrical Data Voltage Range. 414 - 506 Compressor #1 RLA. 6.1 Compressor #1 LRA. 41 Packaged Rooftop Builder 1.45 Page 6 of 9 Project: -Untitled2 Prepared By: Performance Summary For 7.5T GasEle-460v 01/10/2017 07:44AM Compressor #2 RLA. 6.1 Compressor #2 LRA. 41 Indoor Fan Motor Type. MED Indoor Fan Motor FLA- 3.8 Combustion Fan Motor FLA (ea). 0.25 Power Supply MCA- 20 Power Supply MOCP (Fuse or HACR)• 25 Disconnect Size FLA- 20 Disconnect Size LRA- 113 Electrical Convenience Outlet None Outdoor Fan [Qty / FLA (ea)). 2 / 0.8 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 98.4 95.5 85.8 125 Hz 91.6 86.5 84.3 250 Hz 78.4 73.8 80.5 500 Hz 71.1 66.7 78.7 1000 Hz 67.8 63.9 76.4 2000 Hz 66.4 59.0 72.7 4000 Hz 67.8 58.5 68.3 8000 Hz 70.3 58.0 65.1 A -Weighted 79.8 74.8 82.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground- 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction: ___..... .__0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 89.6 Lw B 59.6 68.2 71.9 75.5 76.4 73.9 69.3 64.0 81.4 LwA C 53.4 51.9 48.1 46.3 44.0 40.3 35.9 32.7 57.2 Lp Packaged Rooftop Builder 1.45 Page 7 of 9 Project:—Untitled2 Prepared By: Performance Summary For 7.5T GasEle-460v 01/10/2017 07:44AM D 27.2135.8139.5 43.1 44.0 41.5(36.9 31.6 49.0 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 20 18 16 04 o CO CO 04 133 12 16 20 24 28 32 Airflow(CFM-thousands) RPM =792 BHP=1.80 MaximumRPM=1400 Maximum BHP=4.70 Note:Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC-SystemCurveRP-RatedPoint FanCurve — 2114 =RPM „ao�►,n i , _ \ \ _ —__ __ \ / 700F1A \ i 60CF�M __ _ 3JOIiPM -IggiW i 400RPM i { \ — i •c�- 3.OOBh6� 11 1 1 1 1 1 1 111 1 CI7513113 'I. I ' `I. 1 1,' 11 1 1,\ ' I 11 44 Packaged Rooftop Builder 1.45 Page 8 of 9 Project:-Untitled2 Prepared By: Unit Feature Sheet for 7.5T GasEle-460v 01/10/2017 07:44AM WeatherMaker — 48TC PACKAGED ROOFTOP GAS HEATINGIELECTRIC'COOLING UNITS 3, 4, 5, '6, 7.5, 8.5, 10.12.5, 15 TONS Optional Louvered Hail Guard Shoun %(Q)' f l COMPLIifIIIIJ Puron WEATHERMAKER SERIES Vt:eatherMaker (48TC) units are one-piece gas heating, electric cooling units that are pre -wired and charged with Puron (R-410) refrigerant. They are factory tested in both heating and cooling modes, and rated in accordance with AHRI Standards 210/240 (04-06 sizes) and 3401380 (07-16 sizes). WeatherMaker units are designed in accordance with UL Standard 1995. and listed by the Underwriters' Laboratories. Approved and certified by: AIM OER11AE0. Certified Certified to ISO 9001 STANDARD FEATURES 'INCLUDE: • 'Futon (R-410A)!PPO refrigerant • ASHRAES3.1 energycomptant • Scroll compressors withL'1ternalfiebeakandovaloadprotection • Single_-stagecooEngespsc.tycontrol on04-12models • Two-stage poling capacitycontrofon 08-16 mode'E • S£ER'supto13.0.EER'supto11.1 and IEER's up to 11.8 • Acutro1r refrigerant metering system • Exclusive non -corrosive compose condensate pant) accordancew5h ASHRAE Standard 62. sloping design. side oroenterdrain • Standard cooling operation up to115'F(46"C) anddown to40`F(4°C) - down to 25' !F (-4' C.) whr«lterstart9C. • Pre paintedexteralr;oanetsandip ercoatedinter'sorpanetstestedto 500 hours salt spray protection • Fully insulated cabinet • Exclusive I^GCsolid.statecontrol forcn-boarddingnostioswihLED error code designation burnercontroltogicand energy saving indoor fan motor delay • Low Max modelsthatmeetC,atfomiaAivQualiity Msnagement • Induoeddraft gashe atcombustion desgn • Redundant gas valves with uptotiro stagesofheating • !Low pressure and high pressure switch ioroteced. MAINTENANCE FEATURES: • Aooess panesugh easygri_a handles • Innovative easysta.Ing.no-ship screwsonunitaooesspanels • Two-inch disposable return air f"ers end Tool -less Mei access door • Meth Drive ECM on 3 to 5 ton (-5 voltage pony) models and belt drive evaporator -fan motor and pufeycornbtnations available on at models • flew teminal board facilitating simple safetycrrcuit troubleshooting and simplified control boxarrangernent • ExclusiveIGCso5 -state control foron-boarddiagnostioswith LED error code designation. ibumercontrol logic and energy saving indoor fan motor delay. INSTALLATION FEATURES: • Thru the -bottom; powerentycapabritty • Single point gasand electricconnections • Fut !perimeter baserelwrit'nbuft-in!r ging adapters and fprkslots • Fief convertible frornver:ical to horzontalairflow for slab rnounting. (15 size:nodes require field instated supoly duct cove_r). STANDARD WARRANTY: • 10-yearheatexchanger-15-yearstaintesssteel option • 5-yearcornoressor • 1-yearoarts • 3-yearparts onNovationConden rcoas—wiereavallable_ • Many option alupgradesatsoavailable OPTIONS'INCLUDE BUT ARE NOT LIMITED TO: • iPremlrtink'lr and !Rill Open Wei -Protocol DDC Controls • Supply and Return Air Smoke Detectors. high static :rotors • Louvered condensercorlguards • Economizer.d;issconnectndconvenience outatont"ror . Stainless Ste el heatexchangerostip n . 'Corrosion resstantcotl costing. ▪ 1-turnidi-MZ,et` adaptive dehumidiFicetion system avatabte on al mod etss t h RTPF condense -pits— Motor Master 1 controller included . Ixnged access panels FOT aWfS?et.dro 315 XEJ aSs.ytn rarer r3r' '�:.0dLMcaaCaa'ag;rrrsu7ft Packaged Rooftop Builder 1.45 Page 9 of 9 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER:. M17-0028 DATE: 03/02/17 PROJECT NAME: BOILING POINT. RESTAURANT. SITE ADDRESS: 361 STRANDER BLVD. X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: /AT c Building Division Public Works pi -N\ PcN U Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/07/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/04/17 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: [Pertnii Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 PERFECT CLIMATE INC Washington State Department of Labor & Industries Home Contact Search L&I Page 1 of 2 A -Z Index help My L&S Safety & Health Claims & Insurance Workplace Rights Trades & Licensing PERFECT CLIMATE INC Owner or tradesperson Principals JOSEPH, PAUL GNAMATHU, PRESIDENT Doing business as PERFECT CLIMATE INC WA UBI No. 601 844 179 4426 221ST PL NE REDMOND, WA 98053 206-977-7353 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. PERFECI022D5 Effective — expiration 03/25/1998— 03/12/2018 Bond ................. CBIC Bond account no. SB4087 $6,000.00 Received by L&I Effective date 03/11/2002 03/01/2002 Expiration date Until Canceled Insurance ............... _............. Hartford Casualty Ins Co Policy no. 52SBAIK1378 $2,000,000.00 Received by L&I Effective date 01/18/2017 03/01/2017 Expiration date 03/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts .................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, ut some debts may be recorded by other agencies. License Violations Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601844179&LIC=PERFECI022D5&SAW= 3/23/2017 PERFECT CLIMATE INC No license violations during the previous 6 y eriod. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 884,624-01 ............. _ .......... _ ...... Doing business as PERFECT CLIMATE Estimated workers reported Quarter 4 of Year 2016 "1 to 3 Workers" L&I account representative T2 / KATHY ULRICH (360)902-4829 - Email: WITE235@Ini.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601844179&LIC=PERFEC1022D5&SAW= 3/23/2017 PROJECT IN FON ATIO\ PROJECT DESCIPTIO\ PROJECT ADDRESS 361 STRANDER BLVD., TUKWILA, WA 98188 RESTAURANT CONTACT INFORMATION 13668 VALLEY BLVD. C-2, CITY OF INDUSTRY, CA, 91746 CONTACT: MICHAEL LEE, PHONE: (909) 331-2190 LANDLORD CONTACT INFORMATION REGENCY CENTERS LP 321 STRANDER BLVD., TUKWILA, WA 98188 1. TENANT IMPROVEMENT IN AN EXISTING RESTAURANT 'K's MONGOLIAN GRILL' 1—STORY COMMERCIAL BUILDING (SOUTHCENTER PLAZA). NEW TENANT 'BOILING POINT RESTAURANT', NO CHANGE OF USE AND NO EXTERIOR WORK. 2. WORK INCLUDES INTERIOR TENANT IMPROVEMENT — KITCHEN, DINING AND SERVICE COUNTER. NO STRUCTURAL & EXTERIOR WORK WITHIN THIS SCOPE OF WORK. A3EVIATIO\S COBE FORvATIO\ A.C.T. ACOUSTICAL CLG TILE ADJ. ADJUSTABLE A.F.F. ABOVE FINISHED FLOOR BLK'G BLOCKING C.L. CLR. CLG. C.M.D. G.M.U. COL. CONC. CONT. CONST. CPT. CENTERLINE CLEAR!CLEARANCE CEIUNGG COAL MONOXIDE DETECTOR MASONRY UNIT COLUMN CONCRETE CONTINUOUS CONSTRUCTION CARPET DET. DETAIL DIM. DIMENSION DWG. DRAWING ELEC. ELECTRICAL EQ. EQUAL F.A.R. FLOOR AREA RATIO F.E. FIRE EXTINGUISHER F.F. FINISHED FLOOR F.O.I.C. FURN. BY OWNER INSTALLED BY CONTRACTOR F.0.I.0. FURN. BY OWNER INSTALLED BY OWNER F.R.P. FIRE RATED PANEL FT. FOOT FEET FURN. FURNISHED F.V. FIELD VERIFY GA. G.C. G.W.B. HDWR. H.M. HT. IN INST. INSUL.. GAUGE GENERAL CONTRACTOR GYPSUM WALL BOARD HARDWARE HOLLOW METAL HEIGHT INCH INSTALL INSULATION LAV. L.F. MTL MAT'L MFR. MECH. MIN. M.R. N/A N.I.//C. N.T;S. O.A. O.C. O.H. P—LAM P.L. P.T. PTD. R.C.P. REF. REINF. REQ'D. REV. SHED. S.D. S.F. S.G. SIM. SQ S.O.G. SUSP. S.V. TEMP. T.O. TYP. U.O.N. V.C.T. LAVATORY LINEAR FOOT/FEET METAL MATERIAL MANUFACTURER MECHANICAL MINIMUM MOISTURE RESISTANT NOT APPLICABLE NOT IN CONTRACT NUMBER NOT TO SCALE OVERALL ON CENTER OVERHANG PLASTIC LAMINATE PROPERTY LINE PRESSURE TREATED PAINTED REELECTED CLG. PLAN REFRIGERATOR REINFORCED REQUIRED REVISED/REVISION SCHEDULE SMOKE DETECTOR SQUARE FOOT/FEET SAFETY GLASS SIMILAR SLAB ON GRADE SQUARE SUSPENDED SHEET VINYL TEMPERED TOP OF TYPICAL UNLESS OTHERWISE NOTED VINYL COMPOSITION TILE VENT TO OUTSIDE ZONING: CONSTRUCTION TYPE: PROPOSED OCCUPANCY: OCCUPANT LOAD FACTORS: (REFER TO CHART) PROJECT AREA (NET AREA): EXITS: IMPROVEMENT COST: JURISDICTION: SHOPPING CENTER (COMMUNITY) V (FULLY SPRINKLERED) A 15 NET (DINING) 200 (KITCHEN/SERVICE, 100 (OFFICE)) 300 (ACCESSORY STORAGE) 2,257 SF 2 REQUIRED / 2 PROVIDED $220,000 CITY OF TUKWILA APPLICABLE NATIONAL CODES: • 2015 INTERNATIONAL BUILDING CODE (IBC) • 2015 WASHINGTON STATE ENERGY CODE (WSEC) • CITY OF TUWILA ZONING CODE & ALL LOCAL AMENDMENTS & REGULATIONS OCCUPANT LOAD CALCULATIO\ ROOM ROOM NAME SQ. FT. OCCUPANT LOAD FACTOR OCCUPANT LOAD 001 DINING 963 15 NET 64 002 KITCHEN/SERVICE 416.25 200 2 VICINITY MAP 003 OFFICE 37.5 100 1 N.T S. PROJECT AREA ANDOVER PARK EAST TUKWILA STRANDER BLVD. ANDOVER PARK EAST 004 STORAGE 56.25 300 '1 COMMON AREA 784 0 0 TOTAL: 2, 257 68 Iv EN U ATTACH WITH APPLICATIO\ M c0 J Q P.L. 59' P.L. 5' Jo's A. BANK STARBUC K'S A< \ OCCUPA\T LOA J PLA\ GE \EAL NOTES 1. THIS SET REPRESENTS "THE PERMIT DRAWINGS" AND IS INTENDED TO SHOW MINIMUM REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL CONSTRUCTION NECESSARY FOR THE COMPLETE INSTALLATION OF ALL OPERATING SYSTEMS, MATERIALS AND FINISHES IN ACCORDANCE WITH MFR.'S RECOMMENDATION. CONTRACTOR SHALL THOROUGHLY REVIEW DRAWINGS, SPECIFICATIONS AND OWNER'S REQUIREMENTS. 2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS PRIOR TO BID. DISCREPANCIES IN DIMENSIONS, DRAWINGS, GRAPHIC REPRESENTATION AND ACTUAL FIELD MEASUREMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER. 3. CONSTRUCTION SHALL BE BASED ON THE LOCAL JURISDICTION APPROVED PLANS AND OWNER'S COMMENTS. THE APPROVED PLANS ARE TO REMAIN ON SITE AT ALL TIMES FOR USE BY ALL INVOLVED TRADES AND INSPECTORS. 4. THIS SET OF DRAWINGS SHALL NOT BE COPIED IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN CONSENT FROM THE OWNER. THIS DOCUMENT IS CONSIDERED AS ONE UNIT AND SHALL NOT BE CONSIDERED COMPLETE OR WHOLE IF DOCUMENTS ARE SEPARATED IN ANY MANNER. DOCUMENTS SHALL NOT BE SEPARATED FOR THE PURPOSES OF SUBMITTING PROPOSALS OR FOR SEPARATE PHASES OF CONSTRUCTION. 5. THESE DOCUMENTS ARE PREPARED FOR USE BY THE CONTRACTOR AND IN NO WAY, EITHER IN WHOLE OR IN PART CONSTITUTE ANY DIRECTION OR INSTRUCTION TO ANY CONTRACTOR WITH REGARD TO CONSTRUCTION METHODS, MEANS OR TECHNIQUES. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION WORK INCLUDING, BUT NOT LIMITED TO, SEQUENCE & TEMPORARY SHORING OF ALL EXISTING STRUCTURES & VERIFICATION OF EXISTING UTILITIES & SERVICES. 7. CONTRACTOR SHALL NOTIFY UTILITIES PRIOR TO COMMENCEMENT OF ALL WORK. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRS, SUBJECT TO LOCAL JURISDICTION AND UTILITY INSPECTOR'S FINAL APPROVAL. 8. CONTRACTOR SHALL CLEAN UP ALL PUBLIC RIGHT—OF—WAY AND PRIVATE DRIVEWAYS AFTER EACH WORK DAY. CONSTRUCTION VEHICLES SHALL NOT BLOCK PUBLIC TRAFFIC OR ENTRIES AT ANY TIME. CONTRACTOR SHALL WORK ACCORDING TO LOCAL JURISDICTION'S ALLOWED SCHEDULES ONLY. 9. ALL WORK SHALL COMPLY TO I.B.C. 2015, WASHINGTON STATE ENERGY CODE, LOCAL JURISDICTION ZONING & BUILDING CODES, REGULATIONS, & REQUIREMENTS, LATEST AMENDMENTS (TYPICAL), & KING COUNTY HEALTH DEPARTMENT. P.L. 212.17' J a. STRANDER BLVD. P.L. 434.69' P.L. 133' EXISTING PARKING NO CHANGE P.L. 5' CORNER BAKERY X-FINITY WIRELESS CRICKET JERSEY MIKE'S SUB SUPER CUT 'Pu VISION PLUS BEAUTY OUTLET SIMPLE THAI P.L. 299.79' LEGAL DESCRIPTION: LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 91-9—SS RECORDING NO 9208261819 SAID SHORT PLAT DAF—POR OF SW 4 OF NE 1/4. BEG SW COR OF NE 4 TH N 01-10-24 E 193.57 FT TO S MGN OF STRANDER BLVD TH S 88-15-33 E 665 FT TO POB TH S 01-44-27 W 63 FT TAP OF TANGENT CURVE CONCAVE TO NE RAD OF 130 FT TH SELY ALG SD CURVE THRU ARC OF 34-27-01 ARC LENGTH OF 78.17 FT TH S 88-15-33 E 212.17 FT TH S 01-44-27 W 62 FT TH S 88-15-33 E 9 FT TH S 01-44-27 W 62 FT TH N 88-15-33 W 133 FT TH S 01-44-27 W 150 FT TH N 88-15-33 W 482.33 FT TH S 48-28-37 W 113.91 FT TH S 01-44-27 W 37.10 FT TH N 88-15-33 W 120 FT TH S 01-44-27 W 80 FT TH N 88-15-33 W 84.69 FT TO W LN OF SAID SW 4 TH S 01-10-24 W 687.83 FT TO SW CORNER OF NE 4 TH S 88-06-43 E 1309.38 FT TO W MGN OF ANDOVER PARK WEST TH N 01-03-25 E 1296.97 FT TO S MGN OF STRANDER BLVD TH N 88-15-33 W 641.71 FT TO POB — AKA LOT 2 OF CITY OF TUKWILA LOT LN ADJ NO 88-6—BLA RECORDING NO 8901240241 — LESS PORTION FOR R/W TO CITY OF TUKWILA PARCEL#: 262304-9064 P A \ SCALE: 1"=40'-0" EXISTING PARKING NO CHANGE N A BURGER KING FILE C Permit No. tkl ' tE iia t.•. 0 M snan,cCJ ESIAElcctrical �,Aplumbing ( Gas Piping City of Tukwila V V � G�G�SlGJl� 14632 - 14th Ave. SE Mill Creek, WA 9801 2 (425) 5 12- 1780 dwudesign@gmail.com PROJECT: BOILING POINT RESTAURANT LOCATION: 361 Strander Blvd. Tukwila, WA 98188 TITLE PROJECT INFORMATION, DESCRIPTION, VICINITY MAP, CODE INFORMATION, GENERAL NOTES, ABBREVIATIONS, HEALTH DEPARTMENT NOTES & OCCUPANT LOAD CALCULATION BUILDING DIVISION FILE: 2016-053 DATE: 11/07/2016 PREPARED BY: D. WU Plan review E.T r,�. i., subject Approval of cone n._.;un c.c.cu- aJ: the violation of any adopted code of approved Fieid, and condi By: li/ mom andsiJi,3. it) Car; p+ c _ or ordinm cc y :•,..t sk oels Date: 1/Z3%/'7 City of Iukvila P 1. . 124 INO DIVISION RECEIVED CITY OF TUKWILA MAR 02 2017 REVISIONS: REVISIONS No changes shall be made to the scope PERMIT CES' -E �� FOR of workapproval priorof CODE COMPLl without UIEVVE ANCE Tukwila Building Division.NOTE: Revisions will require a n^ -,w plan submittal and may inC'Lde a ddi:!onai Wan rev;ew fees APPROVED MAR 142011 0 City of T ukwila BUILDING DIVISI SHEET NUMBER: 1 o 'Pu '.; DOLLAR STORE TULIPS LIBERTY MIZU VACANT CHASE PROJECT; NAIL BANK STEAK BANK r AREA HOUSE / ,' A P.L. 299.79' LEGAL DESCRIPTION: LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 91-9—SS RECORDING NO 9208261819 SAID SHORT PLAT DAF—POR OF SW 4 OF NE 1/4. BEG SW COR OF NE 4 TH N 01-10-24 E 193.57 FT TO S MGN OF STRANDER BLVD TH S 88-15-33 E 665 FT TO POB TH S 01-44-27 W 63 FT TAP OF TANGENT CURVE CONCAVE TO NE RAD OF 130 FT TH SELY ALG SD CURVE THRU ARC OF 34-27-01 ARC LENGTH OF 78.17 FT TH S 88-15-33 E 212.17 FT TH S 01-44-27 W 62 FT TH S 88-15-33 E 9 FT TH S 01-44-27 W 62 FT TH N 88-15-33 W 133 FT TH S 01-44-27 W 150 FT TH N 88-15-33 W 482.33 FT TH S 48-28-37 W 113.91 FT TH S 01-44-27 W 37.10 FT TH N 88-15-33 W 120 FT TH S 01-44-27 W 80 FT TH N 88-15-33 W 84.69 FT TO W LN OF SAID SW 4 TH S 01-10-24 W 687.83 FT TO SW CORNER OF NE 4 TH S 88-06-43 E 1309.38 FT TO W MGN OF ANDOVER PARK WEST TH N 01-03-25 E 1296.97 FT TO S MGN OF STRANDER BLVD TH N 88-15-33 W 641.71 FT TO POB — AKA LOT 2 OF CITY OF TUKWILA LOT LN ADJ NO 88-6—BLA RECORDING NO 8901240241 — LESS PORTION FOR R/W TO CITY OF TUKWILA PARCEL#: 262304-9064 P A \ SCALE: 1"=40'-0" EXISTING PARKING NO CHANGE N A BURGER KING FILE C Permit No. tkl ' tE iia t.•. 0 M snan,cCJ ESIAElcctrical �,Aplumbing ( Gas Piping City of Tukwila V V � G�G�SlGJl� 14632 - 14th Ave. SE Mill Creek, WA 9801 2 (425) 5 12- 1780 dwudesign@gmail.com PROJECT: BOILING POINT RESTAURANT LOCATION: 361 Strander Blvd. Tukwila, WA 98188 TITLE PROJECT INFORMATION, DESCRIPTION, VICINITY MAP, CODE INFORMATION, GENERAL NOTES, ABBREVIATIONS, HEALTH DEPARTMENT NOTES & OCCUPANT LOAD CALCULATION BUILDING DIVISION FILE: 2016-053 DATE: 11/07/2016 PREPARED BY: D. WU Plan review E.T r,�. i., subject Approval of cone n._.;un c.c.cu- aJ: the violation of any adopted code of approved Fieid, and condi By: li/ mom andsiJi,3. it) Car; p+ c _ or ordinm cc y :•,..t sk oels Date: 1/Z3%/'7 City of Iukvila P 1. . 124 INO DIVISION RECEIVED CITY OF TUKWILA MAR 02 2017 REVISIONS: REVISIONS No changes shall be made to the scope PERMIT CES' -E �� FOR of workapproval priorof CODE COMPLl without UIEVVE ANCE Tukwila Building Division.NOTE: Revisions will require a n^ -,w plan submittal and may inC'Lde a ddi:!onai Wan rev;ew fees APPROVED MAR 142011 0 City of T ukwila BUILDING DIVISI SHEET NUMBER: 1 o EQUIPMENT LIST C#) DESCRIPTION QTY. DEPTH LENGTH HEIGHT POWER/ INDIRECT DRAIN MAKE MODEL 1 HANDSINK, WALL -HUNG 2 17 1/4" 15 1/4" 13" ADVANCE TABCO 7 -PS -50 2 EXISTING 3 -COMP SINK WI DRAINBOARD BOTH SIDES 1 25.5" 91" 39" PROVIDE INDIRECT DRAIN ADVANCE TABCO 94-3-54-18RL 3A/B EXISTING FOOD PREP SINK W/ DRAINBOARD EACH SIDE 1 25.5" 72" 39" PROVIDE INDIRECT DRAIN SSP INC 1C1 6x20 -D-18 4 2 -DOOR REACH -IN REFRIGERATOR 2 29.5" 54" 78.25" 9 AMP TRUE T -49 -HC 5 2 -DOOR UNDER -COUNTER REFRIGERATOR 1 30" 48" 29-3/4" 3 AMP TRUE TUC -48 -HC 6 ICE MAKER 1 32" 30" 33" 19 AMP PROVIDE INDIRECT DRAIN HOSHIZAKI B-250PF 7 EXISTING MOP SINK 1 21" 25" 10" ADVANCE TABCO 9 -OP -20 8 EXISTING. HOT WATER TANK 1 24" DIA. 60" GAS W/ EXHAUST GE 80 GALLON CAPACITY 9 HANDSINK, DROP-IN 3 13" 19" 10" ADVANCE TABCO DI -1-10 10 EXISTING COMMERCIAL DISHWASHER 1 27" 31" 73" 115V/ 60 HZ AUTO CHLOR A4 LOW TEMP n 11 CASH REGISTER 1 17.3" 19.5" 12.7" 2.5 AMP SHARP ER -A550 12 RICE COOKER 1 23.5" DIA. 17.25 31,200 BTU. RINNAI RER55A--N 13 STAINLESS STEEL WORK TABLE VARIES 23" 48" 26" ADVANCE TABCO KSS -SERIES 14 WALK-IN FREEZER 1 4'-0" 9'-0" 8'-0" CUSTOM 15 WALK-IN COOLER 1 6'-O" 9,-0" 8'-0" CUSTOM 16 A/B A- (2) 6 HOT PLATES & B - (1) 4 -HOT PLATES 2 & 1 2'-6" A -4' B -3' O'-1 O" A-112,000 BTU B-168,000 BTU AMERICAN RANGE A-IHPA-6-36SU B-IHPA-4-24S 17 FOOD PREP TABLE WI REFRIGERATION BELOW 1 2'-10" 4'-O" 3,-4" 8.6 AMP TRUE U� TSSU-48-18M-B 18 DOUBLE STOCK POT 2 1'-6" 3'-6" 2'-0" 180,000 BTU AMERICAN RANGE 1SAP-18-2 19 HOT WATER URN 1 19.90" 10.19" 26.01" 14 AMP BUNN ICB-BLACK 20 RICE WARMER 2 13" DIA. 9 AMP TIGER JFM 21 GLASS DOOR MERCHANDISER 1 24" 25" 63" 115/60/1 TRUE T -12G -LD 22 BLENDER 1 8.75" 7.25" 20" 11.5 AMP VITA -MIX VM01 OOA 23 MEAT SLICER 1 7.5" 11.6" 9" 115/60/1 GLOBE 3850N 24 1 DOOR REACH IN FREEZER 1 29.5" 27" 78" 115/60/1 TRUE T -23F -RC 25 HOT WATER DISPENSER 1 17.4" 5.8" 28.5" 15.4 AMPS BUNN H5E ELEMENT SST NOTE: 1. FULL -HEIGHT STAINLESS STEEL PANEL WALL BEHIND COOKING LINE, TYPICAL. 2. 8'-0" HT. FRP PANELS AROUND KITCHEN WALLS, TYPICAL. 3. USE ENAMEL NON-TOXIC WASHABLE PAINT FOR ALL PAINTED WALLS & WASHABLE CEILING TILE AT ALL FOOD & DRINK PREP AREAS, EXISTING EXTERIOR WALLS & STOREFRONT WINDOWS TO REMAIN TYPICAL, NO WORD DUSTING DOOR, POSTED W/ 1" MIN. LEI (EKING: 'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED' EALTH DEPATh' E\T OYES 1. THE HEALTH DISTRICT OPERATING PERMIT APPLICATION PROCESS MUST BE COMPLETED PRIOR TO OPENING FOR BUSINESS 2. AN INDIRECT WASTE IS REQUIRED FOR THE FOOD PREPARATION SINKS, THREE -COMPARTMENT SINK, ICE MACHINE, AND ANY EQUIPMENT IN WHICH FOOD IS PLACED. 3. A HORIZONTAL SEPARATION OF AT LEAST 16 INCHES OR A VERTICAL PARTITION 16" IN HEIGHT IS REQUIRED BETWEEN THE FOOD PREPARATION SINK AND ALL SOURCES OF CONTAMINATION. 4. A HORIZONTAL SEPARATION OF AT LEAST 16 INCHES OR A VERTICAL PARTITION 16" IN HEIGHT IS REQUIRED BETWEEN THE HAND WASH SINKS AND ALL FOOD PREPARATION AREAS AND COUNTERS. 5. WATER HEATERS MUST BE OF SUFFICIENT SIZE TO PROVIDE HOT WATER TO DISHWASHER AND/OR SCULLERY SINKS AND AT THE SAME TIME PROVIDE HOT WATER TO ALL HAND WASH SINKS. 6. HOT WATER MUST BE AVAILABLE TO ALL HAND WASH SINKS WITHIN 15 SECONDS. 7. EXTRA WALL PROTECTION IS REQUIRED ON WALLS BEHIND SINKS, INCLUDING RESTROOM AND SERVICE AREA HAND WASH SINKS, AND FOOD PREPARATION TABLES. A 16 -INCH HIGH BACK -SPLASH OF PLASTIC LAMINATE, FIBERGLASS - REINFORCED PLASTIC OR EQUAL IS ACCCEPTABLE. WALL PROTECTION BEHIND MOP SINKS MUST COVER THE ENTIRE SPLASH ZONE. PLASTIC COATED HARDBOARD IS NOT ACCEPTABLE. 8. THE FLOOR MUST BE SURFACED WITH A DURABLE, NONABSORBENT, EASILY CLEANABLE MATERIAL. 9. THE CEILING ABOVE THE FOOD PREPARATION AREAS MUST BE NONABSORBENT, NON -PERFORATED, SMOOTH, AND EASILY CLEANABLE. 10. ALL LIGHT FIXTURES IN FOOD PREPARATION AND STORAGE AREAS MUST BE PROVIDED WITH COVERS OR SHATTERPROOF BULBS. 11. PLUMBING MUST MEET STATE AND LOCAL CODES. 12. THE VENTILATION SYSTEM SHALL BE INSTALLED AND OPERATED TO MEET APPLICABLE BUILDING, MECHANICAL, AND FIRE CODES. A PRE -OPERATIONAL INSPECTION IS REQUIRED PRIOR TO OPENING FOR BUSINESS. AT THE TIME OF INSPECTION THE CONSTRUCTION OF THE FOOD SERVICE ESTABUSHMENT MUST BE COMPLETE AND ALL EQUIPMENT MUST BE IN PLACE. INCOMPLETE CONSTRUCTION MAY RESULT IN A REINSPECTION FEE. CONTACT THE FOOD PROGRAM OFFICE A MINIMUM OF ONE WEEK IN ADVANCE TO SCHEDULE AN APPOINTMENT. THIS WILL ENSURE COMPLIANCE WITH THE RULES AND REGULATIONS OF THE STATE BOARD OF HEALTH FOR FOOD SERVICE SANITATION. EXISTING EXTERIOR WALLS & STOREFRONT WINDOWS TO REMAIN TYPICAL, NO WORK EXISTING EXTERIOR WALLS & STOREFRONT UNTYPICAL, NOEWORK EXISTING DOOR, POSTED W/ 1" MIN. LETTERING: 'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED' EXISTING EXTERIOR WALLS & STOREFRONT WINDOWS TO REMAIN TYPICAL, NO WORK >- La - 30'-6" FIELD BANQUET #1 (6 SERVICE AREA EXISTING BOOR TO EMAIN 3'-8" 30Th#1 (4) #2 (4)(4) BOT EXISTING RETAIL TENANT 3 <001> POSTED '68 OCCUPANCY MAX' EXISTING • EMERGENCY EXIT.'SIGNIN .......... BANQU4EET#) 4 3' 8 BANQUET #5 4.3' 8" BANQUET #2 (12) BANQUET #3 (12) 44" EXIT • CLEAR PATHWAY, NO 44" EXIT CLEAR PATHWAY, ENCROACHMENT NO t- 3' 8" 44" EXIT NEW FULL CLEAR HEIGHT PATHWAY, • WALL,. SOLID NO HATCH, TYP ENCROACHMENT ENCROACHMENT 7 74' FIELD VERIFY EXISTING TENANT DEMISING WALL NEW +60" AFF WALL, OPEN HATCH, TYP. 0 `o, EXISTING FLOOR SINK I 3B ( 24) FOR <002> U (3A) FOR (2) \ 1 18" DIVIDER BETWEEN SINKS --- 3' 8" -� F.E. l'EXTINGUISHE -( 11) (16A) ii 44" EXIT -'4- 'WALL BEHIND COOKING UNE: CLEAR PATHWAY, NO ENCROACHMENT • WALL . STUD . W/TYKE ,'X'• GWB. ON BOTH SIDES, STAINLESS. STEEL FULL HEIGHT PANEL ON COOKING LINE SIDE BANQUET #6 (14) <002 �rI SUMP SINK 5) •F� s 16' 3'-87/" E I HOOD PERMIT BY OTHERS 16B Crii)(Tir) • • 44" EXIT • • ' CLEAR PATHWAY, NO -ENCROACHMENT (!hil/iariirioiiiriii/ro�aiirorfrroi� 6 <004> DRY FOOD STORAGE EXISTING DOOR TO REMAIN (J 0 0 0 23 METAL SHELVING ABOVE (13) L_ WALK-IN COOLER. 9'x6' EMPLOYEE LOCKER & FIRST AID KIT STORAGE RACK <003> WALK-IN FREEZER 9'x4' Ca) XIS -TING DOOR TO REMAIN E F.E. EXISTING ELECTRICAL PANELS TO REMAIN TR TO EXISTING FORMER REMAIN 3' 8"- - S RAC GE EXISTING EMERGENCY EXIT SIGN EXISTING TOILETN FINISHES <005> EXISTING TOILET FINISHES ji r <005> EXISTING RFMAJNO EXISTING DOOR TO REMAIN 0 0 0 30'-6" FIELD VERIFY '-EXISTING TENANT DEMISING WALL PROPOSED FL00M PLAN SCALE: 3i" = 1'-0" EXISTING RETAIL TENANT 1- X X w �'�- EXISTING EMERGENCY EXIT SIGN W/ BACK-UP BATTERY, TYP. REMODEL EXISTING SEATING AREA REMODEL EXISTING SEATING AREA EXISTING RETAIL TENANT REMOVE EXISTING COUNTERS 74' FIELD VERIFY FLOOR SINK NOTE: 430" MIN.- 5' MIN. -�- 1) GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FUNCTIONAL TESTING OF AUTOMATIC LIGHTING CONTROLS. 2) SHADED AREA SHOWN ON PLAN IS 44" CLEAR PATHWAY FOR EMERGENCY EGRESS PER 2015 IBC SECTION 1006 & 1008. 3) PATHS OF EGRESS SHALL HAVE AT LEAST AN AVERAGE 1 FOOT-CANDLE AND A MN. AT ANY POINT OF 0.1 -FOOT CANDLE MEASURED ALONG THE PATHS OF EGRESS AT THE FLOOR LEVEL. 4) EMERGENCY EGRESS LIGHT SHOWN ON PLAN ALONG EGRESS PATHWAY. AT EACH END, EXIT LIGHT IS SHOWN. 102) EXISTING DOOR TO REMAIN EXISTING D LETTERING: UNLOCKED AOR P( 'THS I WHA E EXISTING TENANT DEMISING WALL EXISTING - HOT WATER TANK EXISTING 2 -COMP. SINK EXISTING HAND SINK REMOVE EXISTING CIRCULAR TYPE I HOOD & GRILLE REMOVE EXISTING SERVICE COUNTER A n REMOVE EXISTING TYPE II HOOD REMOVE EXISTING INTERIOR REMOVE EXISTING 2 -DOOR FREEZER EXISTING 3 -COMP. SINK EXISTING DOOR TO REMAIN j 0 a 0 ��l J EXISTING EXISTING EXISTING DISH- GREASE MOP SINK WASHER TRAP EXISTING OFFICE TO REMAIN REMOVE EXISTING WALK-IN COOLER EXISTING EMERGENCY EXIT SIGN W/ BACK-UP BATTERY, TYP. EXISTING TOILET NEW FINISHES EXISTING TOILET NEW FINISHES EXISTING DOOR TO REMAIN 0 00 ROOM FINISH SCHEDULE ) AREA WALL CEILING FLOORING 001 DINING DRYWALL WITH GLOSS ENAMEL FINISH PAINT EXISTING 2x4 CEILING GRID & TILE AND GWB SOFFIT CEIUNG, NO WORK NEW TILE FLOORING W/6" COVED AND SEALED GROUT TILE BASE 002 KITCHEN FULL HEIGHT STAINLESS STEEL PANEL BEHIND COOKING UNE. WATER-RESISTANT DRYWALL BEHIND PLUMBING FIXTURES, FRP BOARD AROUND AND 6" SEALED TILE BASE WITH SEALED GROUT EXISTING 2x4 SUSPENDED CEILING GRID AND WASHABLE TILE, RE -WORK TO ADJUST TO NEW LAYOUT QUARRY TILE W/ 6" COVED & SEALED GROUT TILE BASE EXISTING/DEIvIOLITION FLOOR PLAN DOOR SCHEDULE 003 OFFICE/STORAGE PAINTED EXISTING 2x4 SUSPENDED CEILING GRID AND TILE, NO WORK QUARRY TILE W/ 6" COVED & SEALED GROUT TILE BASE WIDTH HEIGHT MATIFINISH REMARKS 004 SERVICE STATION WATER-RES1STANT DRYWALL BEHIND PLUMBING FIXTURES & 4'-0" TILE ABOVE FINISHED FLOOR EXISTING 2x4 SUSPENDED GRID AND WASHABLE TILE AND GWB SOFFIT CEIUNG, RE -WORK TO ADJUST TO NEW LAYOUT QUARRY TILE W/ 6" COVED & SEALED GROUT TILE BASE 005 EXISTING TOILETS WATER-RESISTANT DRYWALL BEHIND PLUMBING FIXTURES & 4'-0" TILE ABOVE FINISHED FLOOR EXISTING GWB SOFFIT CEILING, NO WORK EXCEPT NEW PAINTING NEW TILE FLOORING W/6" COVED AND SEALED GROUT TILE BASE 101 EXISTING EXTERIOR DOORS TO REMAIN. THESE DOORS REMAIN UNLOCK DURING BUSINESS HOURS FOR EMERGENCY EXIT, PROVIDE LIGHTED EXIT SIGN WITH BATTERY BACK-UP 102 EXISTING METAL DOOR TO REMAIN. CONFIRM PANIC HARDWARE IS INSTALLED FOR EMERGENCY EXIT. PROVIDE LIGHTED EXIT SIGN WITH BATTERY BACK-UP SOUD CORE WOOD EXISTING RETAIL TENANT ''-EXISI1NG TENANT DEMISING WALL 1) ALL DOORS REQUIRED FOR ADA COMPLIANCE TO BE FITTED W/ APPROVED LEVER -TYPE HARDWARE & SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. UNLATCHING SHALL NOT REQUIRE MORE THAN ONE OPERATION. 2) MAX. 1/2" THRESHOLD A.F.F. 3) FOR EXISTING EXTERIOR DOORS, PROVIDE PANIC HARDWARE. NO MANUALLY OPERATED FLUSH BOLT OR SURFACE BOLTS ARE NOT PERMITTED. AUTOMATIC FLUSH BOLTS SHALL BE PERMITTED. PER IBC 1008.1.9.3, EXCEPTIONS 2/2.1/2.2/3 (AUTOMATIC FLUSH BOLTS). ri 0020 EXISTING ELECTRICAL PANELS TO REMAIN EXISTING TRANSFORMER TO REMAIN EXISTING DOOR TO REMAIN EXISTING DOOR TO REMAIN EXISTING DOOR LETTERING: '11-1 UNLOCKED WI -I C21WL4 design Mill Creek, WA 98012 PROJECT: BOILING POINT RESTAURANT LOCATION: 361 Strander Blvd. Tukwila, WA 98188 TITLE PROPOSED FLOOR PLAN SCHEDULES FILE: 2016-053 DATE: 11/07/2016 PREPARED BY: D. WU RECEWED CITY OF TUKWILA MAR 0 2 2017 PERMIT CENTER LEGE EXISTING CONDITION TO REMAIN NEW CONSTRUCTION ROOM SYMBOL FIRE EXTINGUISHER DOOR SYMBOL UGHTED EXIT SIGN PER 2015 IBC, SECTION 1008. SIGNS SHALL HAVE ELECTRICAL POWER SUPPLY. IN 'ME EVENT OF FAILURE, THE SYSTEM SHALL BE AUTOMATICALLY PROVIDED WITH POWER FROM AN EMERGENCY SYSTEM PER 2015 IBC, SECTION 1008. EGRESS LIGHTING. EMERGENCY ILLUMINATION SHALL BE INSTALLED AND SHALL HAVE AT LEAST AN AVERAGE OF 1 FOOT-CANDLE AND A MIN. AT ANY POINT OF 0.1 -FOOT CANDLE MEASURED ALONG THE PATHS OF EGRESS AT THE FLOOR LEVEL 101 REVISIONS: COREVIEWEovD=F: PLIANCE MAR 1 4 2017 5. City of Tukwila . MS. torq HEALTH COMMENT HEALTH COMMENT CITY COMMENT SHEET NUMBER: 0 ROLS SEVEN DAY Y PROGRAMMABLE THERMOSTAT, two stage, Honeywell TB8220: Or Equal: . CONTROL NOTES : = 1) System capable of minimum 5 degree deadband, seven day programmable • for each day per week, outside air dampers close'automatically when system is off or upon power failure, interlocked to prevent simultaneous heating and 2) Ailount. a ostator sensor 60:inches above floor. GRILLE 0 L ER SCHEDULE S : • tiauvered. Dotible r•NOT USED UST:. r, Li- 1 D, Sh, ec 903 - Standard fixed blade, NO OBD. Shoemaker 905. Eggcrate, aluminum grid lir, T -bar frame, Shoemaker. L G«'$ NO Standard white finish except as noted. MVAC GERI �s VERIFY site conditions. THERMOSTAT LOCATIONS: Verify all wall mounted control locations with architect CODES: Oa . all local ,& state governing codes. COORDINATE ductwork and grille locations with lighting and other related tra with architect approval. Verify clearances & ceiling elevations before instailatil L DRAWINGS are schematic in some areas and may not show exact routing or el offset which may be required. Provide a complete & properly working system with all necessary items F SEISMIC BRACING: Provide to meet local code requirements. Refer to the SHRAE standards aPradkaleGuide to Seismic Restraint', 1999. TEST, ADJUST, & BALANCE: Provide proper system testing, adjusting, and balancing on both air and water according to NEBB & ASHRAE standards, including written reports. Use only technicians qualified & trained in TAB wor Include System Commissioning: Functional testing of sequences of operation erisrarellvey oplesata= : acooence with the mechanical plans. :01117 ri. DUCT NOTES DUCT CONSTRUCTIO and installation- per latest SMACNAStandardS and -the 2012 uas required by the;fit .€o& a��meat ch:ct, except. as:^.etcr. Underground duct shall be "Spunstrand" factory insulated fiberglass construction. - BALANCING DAMPERS: Provide on all supply grille run out ducts up stream of grille. DUCT II t TION: Manville 3iL er s=dtrct. rA. type 75. _FSK aluminum foil facing or equal. Outside air ducts in conditioned space = R-7 with vapor barrier; Supply & return: in unconditioned space =1-6, outside building envelope = it -8. EXCEPTIONS: No insulation required where the design temperature difference between interior and exterior of the duct does not exceed 15°F. Supply ducts which convey supply air at temperatures less than 55°F or greater than 105°F sha be;insulated~ 1. minr R-3.3 w ula rrwhere located within conditioned space. 1 2012 MSEC sec. C403.2.7.2. DUCT SEALING -GENERAL: 0 to 2° static pressure - sear all seams and joints on all ducts. Higher static pressures - refer to 2012 IMC for additional requirements. Inside build:. DuroDyne "DDS -181 "gray or approved equal per UL. 181 A -M, 18111 Illy listed. Outside: Polyurethane, Mameco Vulkem 116. OR approved equal. 2012 WSEC sec. C4032.7.3. TURN VANES: Provide sine thickness dun vanes (detail) in all major square duct elbows, tees, or turns with inside radius less than 314 dud width. Square branch duct taps shall be 45 degree type per SMACNA standard. FLEX DUCT (Insulated): For grille run outs up to 6 ft. long, except as noted. Provide adjustable metal elbows on all turns, unless a smooth full radius turn is made.: Secure core with, approved nylon ormem warcn.drive damps. NO duct tape joints & screws allowed: SOUND LINER: Provide sound tnec rnet`al supply & return ducts as shown on plans. Johns Manville Linacoustic RC flexible fiberglass liner with Permacote acrylic surface treatment or equal. Fabricate and install per duct liner standard of North American Insulation Manufacturer's Assoc. FLEX CONNECTORS: Provide on all duct hook-ups to isolate air handling merit i eopr a mated fiberglass fabric type). f o e• gevr y e SUbStittited for ctangular ducts that are NOT LINED. Provide circular equivalent of rectangular Other equivalent rectangular duct sizes may be substituted to better fit ti\EC..\\ ilk)NC. 'A 9t tiltti`` : '- o'` n c� comer 6A, Q 511 Soce- f3 (r_ n•Ss) Sou £Fs. ex.5s Spsaval • I att Rtx� ?L 5c -me REVIEWED FOR CODE COMPLIANCE APPROVED MAR 142017 • City of Tukwila Bl .„VISION CITY OF TUKWILA MAR 02 2017 PERMIT CENTER 24X3 CLEARPREITG REVISIONS MIN -NG- IV\WE.L. Tor. -.)S C- -i.A . fr amu_ ism' -E'Con-,0 • I Siv,t'(C ¶XT (&' xL. C.ts_k-z.-st 4e -c -U , ?.s' 3cx.c� all SU gcx,& y05 ee S'/i 9WcT tZ Z_ \, C list tlC9TLC3 7• s 30 Uv 411-1 S C.is 9.-0Of Nists NI 3 7'3 iMI.,U dS A- -'Al- 6 C4'. rz-7-cu L d 6S0 C' - SOnix[rlls: riCac ? . PR„, _... ,1 fi1 _race Sac \Zo v- . i att Rtx� ?L 5c -me REVIEWED FOR CODE COMPLIANCE APPROVED MAR 142017 • City of Tukwila Bl .„VISION CITY OF TUKWILA MAR 02 2017 PERMIT CENTER 24X3 CLEARPREITG REVISIONS BY I en in 1 (1 1 §Fl S 2 - j i • Date 2 ...2,,,_ i -7 Scale 1f 4'` Drawn PS Job l 0 k Sheet .1\ 1,.. Of S eets