Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M17-0030 - OFFICE DEPOT - GAS PACK REPLACEMENT
OFFICE DEPOT 300 ANDOVER PARK W SUITE 400 MI 7-0030 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049001 Permit Number: M17-0030 300 ANDOVER PARK W 400 Issue Date: Permit Expires On: OFFICE DEPOT 4/10/2017 10/7/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SEGALE PROPERTIES LLC PO BOX 88028, TUKWILA, WA, 98138 CHRIS TAYLOR 109 WASHINGTON BLVD - SUITE B , ALGONA, WA, 98001 FIVE STAR MECHANICAL 109 WASHINGTON BLVD, SUITE B , ALGONA, WA, 98001 FIVESM*0101T Phone: (206) 851-9812 Phone: (253) 852-8284 Expiration Date: 5/1/2018 DESCRIPTION OF WORK: REPLACEMENT OF (1) 12.5 TON GAS PACK Valuation of Work: $22,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $493.49 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree t• e conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 5: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 6: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: Readily accessible access to roof mounted equipment is required. 15: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 16: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 17: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 18: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 19: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 20: ***MECHANICAL PERMIT CONDITIONS*** 21: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 22: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 0703 1800 0609 0705 0701 0702 FIRE FINAL MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL SMOKE DETECTOR TEST a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.aoy Mechanical Permit No. M ( 7 0030 Project. No. Date Application Accepted: (� Date Application Expires: '"l `.(7 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: '1)00 /V.A03t. - ?QV- We - Suite Number: y, O J Floor: Tenant Name: 0 : Q tc. p+ PROPERTY OWNER Name: �� S —T -s 1 Address: 106\ .%.)Ph. • `‘) Name: Phone: ot) YS 1, ,t5i i2Fax: 251 4SZ iZsS Email: cL -t @. c--,..,- --5404-1."4.c % . Ca"c- Address: 5'D `1 �2_, c1 \' Qq--- or. C � I k..0....._City:--. State: IPJ A- Zip:c\c{t(6V CONTACT PERSON - person receiving all project communication Name: �� S —T -s 1 Address: 106\ .%.)Ph. • `‘) �q City: /� ` Stat"°l,`ti 0') Phone: ot) YS 1, ,t5i i2Fax: 251 4SZ iZsS Email: cL -t @. c--,..,- --5404-1."4.c % . Ca"c- New Tenant: ❑ Yes VI.. No MECHANICAL CONTRACTOR INFORMATION Company Name: ( Address: 9 ) Phone:2 Fax: 6 ,6_Sa- c25tq • a ws.. ,,,i5 Contr Reg No. p Date: 1�FS�+�olo�p 5 `t lis Tukwila Business License No.: q tdS _ ocla,'2 X17 J.' Valuation of project (contractor's bid price): $ Describe the scope of work in detail: L) 19-.5 1 '— Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Ute— ' Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu t Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent ' i Comiercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65'dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system ' i Comiercial Hood and duct 47 dB(A) Incinerator — domestic 65'dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Noise: j . , Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 *Daytim District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) . ' i Comiercial 57 dB(A) 47 dB(A) 60 dB(A) 65'dB(A) Industrial ' 60 dB(A) 50 dB(A) ' ' 65 dB(A) 70 dB(A) A few sounds are exempt.from the'noise code, including: •, Warning devices; •1Construction and property maintenance during the daytime hours (7am-lOpm); • Testingof backup generators during the day. r✓ PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS O THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ►. Signature: Print Name: C("r•�� Day Telephone: e7SSC) C6S °VC lZ Mailing Address: L O°\ � l,.�r �,r.__ )\•J Akh a x/04-- o� •� J State Zip OR AUT}tQ D ENT: Date: �-�(1/4.. l7 H:\Applications\Forms-Applications On Line\2016 Applications \Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R11182 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $396.30 M17-0030 Address: 300 ANDOVER PARK W 400 Apn: 2623049001 $396.30 MECHANICAL $377.43 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $344.28 TECHNOLOGY FEE $18.87 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11182 R000.322.900.04.00 0.00 $18.87 $396.30 Date Paid: Thursday, March 30, 2017 Paid By: WARE ENTERPRISES INC Pay Method: CHECK 5621 Printed: Thursday, March 30, 2017 1:44 PM 1 of 1 CRSYSTEMS DESCRIPTIONS 1 PermitTRAK ACCOUNT 1 QUANTITY PAID $97.19 M17-0030 Address: 300 ANDOVER PARK W 400 Apn: 2623049001 $97.19 Credit Card Fee $2.83 Credit Card Fee R000.369.908.00.00 0.00 $2.83 MECHANICAL $94.36 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R11016 R000.322.102.00.00 0.00 $94.36 $97.19 Date Paid: Monday, March 06, 2017 Paid By: STEVE BAKER Pay Method: CREDIT CARD 008034 Printed: Monday, March 06, 2017 11:08 AM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M17-oo3r) Project: /� bePO �'"' Type o Insctiion:: p�� (COL ic&101-- (dre/ss 004/' /ii I •1;g_ Date Called: Ca.rn .m. Special Instructions: St.l4e--l Date Wanted: Requester: Phone No: 1141 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: r'IPC.[nowtcal FIN?—6pKovr,t) Inspector:3 Date: 4-/-9-20/6" REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD vip Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION M 1 Z - 0030 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 0 -r14,E. cie.ptir T of Ins ection: so- Add -fess: 300 M . 0 A. .,. 4)M - FINAL. Special Instructions: 444O 0 Date Wanted: a.m. 'II— Z—Z0 p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: e r t cs, 4 t.►'►,4.l. .4frvp\rc Inspector: ,8cp /) Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 rAll -0030 : -. Project0 f- Fi 6 t.. b 4. Type of Inspection: Address 300 Ajli f( Called: Special Instructions: 0 oo) Date Wanted — 2 ^ lg a.m. p.m. Requester: Phone No: 0 Approved per applicable codes. E Corrections required prior to approval. COMMENTS: smoke DeAeekt,i---530"- Inspector: Z:V ag„ I1 Date: • r REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. L c) , INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., COG, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: N .'s 5 2r7A/6- 6 Ty e of Inspection: iiEzil Date Called: gi,_. Address: /745 1`;''-- f‘ Special Instructions: Date Wa te.: Requeste Phone No: .4 Approved per applicable codes. E] Corrections required prior to approval. COMMENTS: C R0064-1- i N, 4 c1iC/ L Inspector: Date: _l L'7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1140-61930 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ,Pa4- Type of Inspection: 7%- %Addr®,gce ess: Address: Suite #: 0 V Contact Person: Special Instructions: Pre -Fire: Phone No.: KApproved per applicable codes. Corrections required prior to approval. COMMENTS: .4W --,z-- /4,(.1 ,,-5,,, ite_ fwe,r1"/ /f ;SD -y-, Monitor: Pre -Fire: `` Permits: Occupancy Type: , AThf - Ecols l Ad iii/'h Needs Shift Inspection: Sprinklers: S 3 Fire Alarm: , Hood & Duct: `\ Monitor: Pre -Fire: `` Permits: Occupancy Type: , Inspector: --------e_._ S 3 Date: e --s 7/es Hrs.: V 0 fit/7L- - $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip:_ Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECi`ION-RECORD Retain a copy with permit. MI 1— UU..Jv. PERMIT NUMBERS CITY OF\TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 0,n( --e- Gee, t-- Type of Ins a -ion: Address: Suite #:'co ,, w VOO Contact Person: r Special Instructions: Phone No.: "t Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: }. Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: ( r". /VV 2 v / .g -TTA . /A -'57/701(a/(/- . ,' -i L.,-- 0 , D ...''„ 1 G/w cQ les/4- "2.; --No ! i' ,4 / e-, s'0 , $ No «T 1-) Needs Shift Inspection: Sprinklers: Fire Alarm: - Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 512 Date: G%/y1 r Hrs.: $100.00 REINSPECTION(FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Johnson 'J %,k11 .centrols • Code No. LIT -1900795 Issued March 26, 2013 VSD Series II Variable Speed Micro Drives Description Johnson Controls® VSD Series 11 Variable Speed Micro Drives (JC-VSM II) are the next generation of drives specifically engineered for today's HVAC mid -market applications. These micro -processor -based drives have standard features that can be programmed to tailor the drive's performance to suit a wide variety of application requirements. The JC-VSM 11 product line uses a 32-bit microprocessor and insulated gate bipolar transistors (IGBTs) that provide quiet operation, high efficiency, and smooth low -speed performance for three-phase induction motors. The size and simplicity of the JC-VSM 11 makes it ideal for hassle -free installation. Models rated at 575 volts, three-phase, 50/60 Hz are available in sizes ranging from 1 to 7-1/2 hp. Models rated at 480 volts, three-phase, 50/60 Hz are available in sizes ranging from 1/2 to 10 hp. Models rated at 230 volts, single or three-phase, 50/60 Hz are available in sizes ranging from 1/4 to 3 hp, 230 V three-phase output. Models rated at 115 volts, single-phase, 50/60 Hz are available in 1/4 to 1-1/2 hp, 230 V three-phase output. The standard drive includes a digital display, and operating and programming keys on a visually appealing, efficient application programming interface. The display provides drive monitoring, as well as adjustment and diagnostic information. The keys are used for digital adjustment and programming of the drive, as well as for operator control. Separate terminal blocks for control and power wiring are provided for customer connections. Refer to the VSD Series 11 Variable Speed Micro Drives Product Bulletin (LIT -12011813) for important product information. Features • Preset Application Macros, Startup Wizard, and Diagnostic Capabilities — allows for quick and easy startup • Rugged Construction — offers 122°F (50°C) rated, conformal coated boards • DIN Rail and Screw Mountable Chassis — reduces installation time • Compact, Space Saving Design — allows for side-by-side installation resultin in less mounting space • Industry -Leading Efficiency — elivers energy savings to the custome . rovidels integrated EMC filters and brake choppers as standard features in three-phase applications, which make the unit suitable for commercial and industrial applications. • IP 20 Enclosure Class Available as Standard — offers IP21/NEMA Type 1 kits Temperature -Controlled Fan — ensures extended product reliability • RS-485/Modbus® — includes a standard communication protocol • PID Controller — provides stand-alone, closed-loop control Programmable Parameters Application macros: basic, pump, fan, and high -load • Programmable start and stop and reverse signal logic (sinking or sourcing) • Reference scaling VSD Seriesjll Variable Speed Micro Drive Selection Chart (Single-phase Input, 3 -Phase Output) (Code Number 11/ IS 11 Programmable start and stop functions • DC brake at start and stop • Programmable V/Hz curve • Adjustable switching frequency • Auto restart function after fault • Protections and supervisions (all fully programmable; off, warning, and fault) • Current signal input fault • External fault • Fieldbus communication • Eight preset speeds • Analog input range selection, signal scaling, and filtering • PID control) Repair Info If a VSD Series fails to operate contact the nea representative. 0 4 B M 0101010 Base Product VS = Variable Speed Series 11 Micro Drive prefix Full Load Amperes (VT/CT) 1D7=1.7A(1/4hp, 0.25kW)1•2 2D4 = 2.4 A (1/2 hp, 0.37 kW)12 2D8 = 2.8 A (3/4 hp, 0.55 kW)12 307 = 3.7 A (1 hp, 0.75 kW)1.2 408 = 4.8 A (1.5 hp, 1.1 kW)1.2 700 = 7.0 A (2 hp, 1.5 kW)2 9D6=9.6A(3hp, 2.2k\ 2 Voltage 0 = 120 V 2 = 230 V Enclosure Rating 0 = IP20 Enclosure Style 4 = Single-phase (Micro Drive) Revision # B = Rev. 2 (Americas) D = Rev. 2 (Canada) Separator (—) Communications M = Modbus Options 00 = None EM = EMC Filter 1. 120 Volts 2. 230 Volts Note: Horsepower ratings are based on the use of a 240 V four- or six -pole squirrel -cage induction motor and are for reference only. Select a drive where the motor current is less than or equal to the rate . continuous output current. REVIEWED FOR tb'hE COMPLIANCE 11 Variabl aF'p° eMcn5 DD- rr,e ithin its specifications, est Johwpi ontr�ols o 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 03 2017 PERMIT CENTER 7- opo The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2013 Johnson Controls, Inc. www.johnsoncontrols.com 1 Johnson . Controls VSD Series l/ Variable Speed Micro Drives (Continued) Selection Chart (3 -Phase Input, 3 -Phase Output) Code Number 1V I S 0 3 B M o to lo lo Base Product VS = Variable Speed Series II Micro Drive prefix Full Load Amperes (VT/CT) 230 V 1D7 = 1.7 A (1/4 hp, 0.25 IMO 2D4 = 2.4 A (1/2 hp, 0.37 kW) 2D8 = 2.8 A (3/4 hp, 0.55 kW) 3D7 = 3.7 A (1 hp, 0.75 kW) 4D8 = 4.8 A (1.5 hp, 1.1 kW) 7D0 = 7.0 A (2 hp, 1.5 kW) 011=11.OA(3hp, 2.2WI) 017 = 17.0 A(5 hp, 4kW) 025 = 25.0 A (7.5 hp, 5.5 kW) 031=31.OA(10 hp, 7.5 kW) 038 = 38.0 A (15 hp, 11 kW) 480V 1D3=1.3A(1/2hp, 0.37kW) 1D9 = 1.9 A (3/4 hp, 0.55 kW) 2D4 = 2.4 A (1 hp, 0.75 kW) 3D3 = 3.3 A (1.5 hp, 1.1 kW) 403 = 4.3 A (2 hp, 1.5 kW) 5D6 = 5.6 A (3 hp, 2.2 MN) 7D6 = 7.6 A (4 hp, 3 kW) 900=9.0A(5hp, 4kW) 012=12.0A(7.5hp, 5.5kW) 014=14.OA(10hp, 7.5kW) 016=16.OA(10hp, 7.5kW) 023 = 23.0 A (15 hp, 11 kW) 031=31.OA(20hp, 15kW) 038 = 38.0 A (25 hp, 18.5 kW) 575 V 1D7 = 1.7 A (1 hp, 0.75 kW) 207 = 2.7 A(2 hp, 1.5 kW) 3D9 = 3.9 A (3 hp, 2.2 kW) 6D1 = 6.1 A (5 hp, 4 kW) 900=9.OA(7.5hp, 5.5kW) Voltage 2 = 230 V 4 = 480 V 5 = 575 V Enclosure Rating 0 = IP20 Enclosure Style 3 = 3-phase (Micro Drive) Revision # B = Rev. 2 (Americas) D = Rev. 2 (Canada) Separator (-) Communications M = Modbus Options 00 = None EM = EMC Filter Note: Horsepower ratings are based on the use of a 240 V, 460 V, and 575 V four- or six -pole squirrel -cage induction motor and are for reference only. Select a drive when the motor current is less than or equal to the rated continuous output current. The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2013 Johnson Controls, Inc. www.johnsoncontrols.com 2 Johnson 4,:f0 ,C1 ntrols VSD Series 11 Variable Speed Micro Drives (Continued) Technical Specifications The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2013 Johnson Controls, Inc. www.Johnsoncontrols.com 3 VSD Series II Variable Speed Micro Drives (Part 1 of 2) Input Voltage (Vin) +10%/-15% (575V units: +15%/-15%) Input Frequency (fin) 50/60 Hz (Variation Up to 47-66 Hz) Connection to Power Once Per Minute or Less (Typical Operation) Output Voltage 0 to Vin 11 Continuous Output Current Ambient Temperature Maximum 104°F (40°C), Overload 1.1 x IL (1 min./10 min.) Initial Output Current Current 2 x IN for 2 Seconds in Every 20 -Second Period, Torque Depends on Motor Output Frequency 0 to 320 Hz Frequency Resolution 0.01 Hz Control Method Frequency Control (V/f) Open Loop Sensorless Vector Control Switching Frequency 1.5 to 16 kHz; Default 6 kHz Frequency Reference Analog Input: Resolution 0.1% (10 bit), Accuracy +/-1% Panel Reference: Resolution 0.01 Hz Field Weakening Point 30 to 320 Hz Acceleration Time 0 to 3,000 s Deceleration Time 0 to 3,000 s Braking Torque DC Brake: 30% x Tn (without Brake Option) Braking Resistor2 230 V: Frame 2, 35 ohms; Frame 3, 26 ohms 480 V: Frame 2, 75 ohms; Frame 3, 54 ohms 575 V: Frame 3, 103 ohms Ambient Operating Temperature 14°F (-10°C), No Frost to 122°F (+50°C): Rated Loadability I N Storage Temperature -40 to 158°F (-40 to 70°C) Relative Humidity 0 to 95% RH, Noncondensing, Noncorrosive, No Dripping Water Air Quality Chemical Vapors: IEC 721-3-3, Unit In Operation, Class 3C2; Mechanical Particles: IEC 721-3-3, Unit In Operation, Class 3S2 Altitude 100% Load Capacity (No Derating) Up to 3,280 ft (1,000 m); 1% Derating for Each 328 ft (100 m) Above 3,280 ft (1,000 m); Maximum 6,560 ft (2,000 m) Vibration 60068-2-6; 3 to 150 Hz, Displacement Amplitude 1 mm (peak) at 3 to 15.8 Hz, Maximum Acceleration Amplitude 1 G at 15.8 to 150 Hz Shock EN 50178, IEC 68-2-27 UPS Drop Test (for Applicable UPS Weights); Storage and Shipping: Maximum 15 G, 11 ms (In Package) Enclosure Class IP20 EMC (at default settings) Category C2, C3, and C4 (Level H): With an Internal RFI Filter Option Emissions EMC Level Dependent: +EMC 2: EN 61800-3 (2004) Analog Input Voltage 0 to 10 V, R = 200 kOhms Differential Resolution 0.1 %; Accuracy ±1 %, Dip Switch Selection (Voltage/Current) Overcurrent Protection Trip Limit 4.0 x IH Instantaneously Overvoltage Protection 115/230 V Series: 437 VDC; 400 V Series: 874 VDC; 575 V Series: 1048 VDC Trip Level Undervoltage Protection 115/230 V Series: 183 VDC; 400 V Series: 333 VDC; 575 V Series: 460 VDC Trip Level Earth Fault Protection Ground fault is tested before every start. In case of ground fault in motor or motor cable, only the frequency converter is protected. Overtemperature Protection Yes Motor Overload Protection Yes Motor Stall Protection Yes Motor Underload Protection Yes Compliance CE UL Listed File No 508C; cUL Listed, IEC, RoHS Compliant CE Mark — Johnson Controls, Inc. declares that the VSD Series II Variable Speed Micro Drives are in compliance with the essential requirements and other relevant provisions of EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC. Safety — EN 61800-5-1 Warranty 30 months (parts only) from date of shipment Reliability 500,000 hours Mean Time Between Failures (MTBF) Weight FS1: 1.21 Ib (0.55 kg) FS2: 1.54 Ib (0.69 kg) FS3: 2.18 Ib (0.99 kg) Single -Phase Voltage/hp/Amperes FS1 230 V, 1/4 to 3/4 hp, 0.25 to 0.55 kW, 1.7 to 2.8 A The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2013 Johnson Controls, Inc. www.Johnsoncontrols.com 3 Jf. Joh,son'/,kt ,Cntrols VSD Series 11 Variable Speed Micro Drives (Continued) 1. The exception is 115 V single-phase in, 230 V 3-phase out. 2: Frame 2 and Frame 3, 3-phase drives are equipped with a brake chopper circuit. The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. m 2013 Johnson Controls, Inc. www.Johnsoncontrols.com 4 VSD Series II Variable Speed Micro Drives (Part 2 of 2) FS2 120 V, 1/4 to 1 hp, 0.25 to 0.75 kW, 1.7 to3.7A 230 V, 1 to 2 hp, 0.75 to 1.5 kW, 1.7 to 7 A FS3 120 V, 1.5 hp, 1.1 kW, 1.7to3.7A 230 V, 3 hp, 2.2 kW, 4.8 A Three -Phase Voltage/hp/Amperes FS1 230 V, 1/4 to 1 hp, 0.25 to 0.75 kW, 1.7 to 3.7 A 480 V, 1/2 to 1.5 hp, 0.37 to 1.1 kW, 1.3 to 3.3 A FS2 230 V, 1.5 to 2 hp, 1.1 to 1.5 kW, 4.8 to 7 A 480 V,2to3hp, 1.5 to 2.2 kW, 4.3 to5.6A FS3 230 V, 3 hp, 2.2 kW, 11 A 480 V, 3 to 10 hp, 3 to 7.5 kW, 7.6 to 16 A 575 V, 1 to 7.5 hp, 0.75 to 5.5 kW, 1.7.to9A 1. The exception is 115 V single-phase in, 230 V 3-phase out. 2: Frame 2 and Frame 3, 3-phase drives are equipped with a brake chopper circuit. The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. m 2013 Johnson Controls, Inc. www.Johnsoncontrols.com 4 COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS Model 580D Sizes 036-150 3 to 121/2 Tons IEWE _�� C©MPr_ wiara= ;-JPROVED APR 0 4 2017 580D036-072 Standard -Efficiency Rooftop Units with: City of Tukwila BUILDING QM,PAoIENT OPERATION AND DEPENDABLE PER- FORMANCE — Compressors have vibration isolators for quiet operation. Efficient fan and motor design permits operation at low sound levels and all 580D units are mounted either on mounting plate (036-072) or on an exclusive polycore plate (090-150). The 580D090-150 units offer lower utility costs through part - load operation using 2 stages of cooling. Quiet and efficient operation is provided by belt -driven evapo- rator fans (standard on all units over 5 tons). The belt -driven evaporator -fan is equipped with variable -pitch pulleys which allow adjustment within the rpm ranges of the factory -supplied pulleys. Increased operating efficiency is achieved through computer - designed coils featuring staggered internally enhanced copper tubes. Fins are ripple -edged for strength, lanced, and double waved for higher heat transfer. Tubular, dimpled gas heat exchangers optimize heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air. The dimpled design creates a turbulent gas flow to maximize heat- ing efficiency. The California Air Quality Management Districts NO, require- ment of 40 nanograms/joule or less is met when Low NO, Kit CRLOWNOX001A00 is installed on 036-060 sizes. The extra thick AlumagardTM heat exchanger coating provides corrosion resistance and ensures long life. The unsightly appearance of flue stacks is eliminated and the effects of wind on heating operations are diminished by the induced draft combustion system. The inducer fan draws hot combustion gas through the heat exchanger at the optimum rate for the most effective heat transfer. The heat exchanger operates under negative pressure, preventing flue gas leakage into the indoor supply air. MAR 03 2017 580D090-150 PERMIT CENTER • Exclusive integrated gas control board with diagnostics • AlumagardTM heat exchanger coating • Induced -draft fan for gas combustion • Tubular, dimpled heat exchangers • Pre -painted galvanized steel cabinet for long life and quality appearance • Commercial strength base rails with built-in rigging capability • Convertible design to horizontal supply/return • Non -corrosive, sloped condensate drain pan, meets ASHRAE 62 (IAQ) • Two-inch return -air filters • A wide assortment of factory -installed options available FEATURES/BENEFITS Every compact one-piece unit arrives fully assembled, charged, tested, and ready to run. INTEGRATED GAS CONTROLLER (IGC) — All ignition com- ponents are contained in the compact IGC which is easily accessible for servicing. The IGC control board, designed and manufactured exclusively for rooftop units, provides built-in diagnostic capability. An LED (light -emitting diode) simplifies troubleshooting by providing visual fault notification and system status confirmation. The IGC also contains an exclusive anti -cycle protection for gas heat operation. After 4 continuous cycles on the unit high- temperature limit switch, the gas heat operation is disabled, and an error code is issued. This feature greatly improves reli- ability of the rooftop unit. The IGC also contains burner control logic for accurate and dependable gas ignition. The LED is visible without removing the unit control box access panel. This LED fault -notification system reduces service person troubleshooting time and mini- mizes service costs. The IGC also maximizes heating effi- ciency by controlling evaporator -fan on and off delays. M L1003i Form No. PDS 580D.36.9 During the Heating mode, the evaporator -fan relay automati- cally starts the evaporator fan after the heat exchanger warms up to a suitable temperature. The 30 -second fan delay prevents cold air from entering the supply duct system when the condi- tioned space is calling for heat to maximize efficiency. The direct -spark ignition system saves operating expense when compared to pilot ignition systems. No crossover tube is required, therefore no sooting or pilot fouling problems can occur. All 580D standard units are designed for natural gas, but an accessory LP (liquid propane) conversion kit is available. SAFETY IS BUILT IN — All 580D units have a flame rectifica- tion sensor to quickly sense the burner flame and ignite burners almost immediately. Fast shutdown is a certainty since the sen- sor reacts quickly to any flame outage or system failure. In the event of a shutdown, an error code is issued at the IGC board. Safety is also assured due to the heating safety controls which will shut down the unit if there is a problem. If excessive temper- atures develop, limit switches shut off the gas valve. After 4 con- tinuous short cycles of the high-temperature limit switch, the IGC board locks out the gas heat cycle to prevent any further short cycles. This safety feature is provided exclusively on Bryant rooftop units. The rollout switch also deenergizes the gas valve in the event of a flame rollout. DURABLE, DEPENDABLE CONSTRUCTION — Designed for durability in any climate, the weather -resistant cabinets are con- structed of galvanized steel and bonderized, and all exterior panels are coated with a prepainted baked enamel finish. The paint finish is non -chalking, and is capable of withstanding ASTM (American Society for Testing and Materials) 8117 500 -hour Salt Spray Test. All internal cabinet panels are primed, permitting longer life and a more attractive appearance for the entire unit. In addition, the 580D090-150 units are designed with a single, continuous top piece to eliminate any possible leaks. Totally enclosed condenser -fan motors and permanently lubricated bearings provide additional unit dependability. EASY INSTALLATION AND CONVERSION — All units are shipped in the vertical discharge configuration for fit -up to stan- dard roof curbs. (Two different curb sizes fit unit sizes 036-072 and 090-150, respectively.) The contractor can order and install the roof curb early in the construction stage, before decisions on size requirements are made. All units feature roll -formed base rail design with forklift slots and rigging holes for easier maneuvering. (Forklift slots are found on 3 sides for 580D units.) The standard 580D036-060 units have operating weights under 500 Ib and durable packag- ing protects all units during shipment and storage. The units can be easily converted from a vertical to a horizontal discharge configuration by relocating the panels supplied with the unit. The non -corrosive sloped condensate pan permits either an external horizontal side condensate drain (outside the roof curb) or an internal vertical bottom drain (inside the roof curb). Both options require an external, field -supplied P -trap. Also, the condenser coil grille (available on 036-072 sizes as a field - installed accessory) provides a metal plate as an alternate loca- tion for the field -supplied disconnect, if desired. The 580D units were designed with service technicians in mind. The single -row condenser coils on the 580D036-072 and 090 units simplify the cleaning process. The efficient in -shot burners and all ignition components are contained in an easily remov- able, compact assembly. The 580D units also have a standard filter access panel, which permits tool -less filter changes, even on units with horizontal economizers. 2 SIMPLE ELECTRICAL CONNECTIONS — Terminal boards, located in the base unit control box, facilitate connections to room thermostat, outdoor thermostat(s), and economizer. Ser- vice panels are quickly removed, permitting easy servicing. Thru-the-bottom service connection capability (with accessory) allow power, control wiring, and gas to be routed through unit base pan, minimizing roof penetrations. Gas, power, and control connections are made on the same side of the unit to simplify installation. In addition, color -coded wires permit easy tracing and diagnostics. PROVEN COMPRESSOR RELIABILITY — Design techniques feature computer -programmed balance between compressor, condenser, and evaporator. Bryant -specified hermetic compres- sors are equipped with compressor overcurrent and overtem- perature protection to ensure dependability. All 580D units have Bryant's exclusive fixed orifice metering device which precisely controls refrigerant flow, preventing slug- ging and flood -back, while maintaining optimum unit perfor- mance. Filter driers are standard. INTEGRATED ECONOMIZERS AND OUTDOOR AIR — Optional economizers and manual outdoor -air dampers intro- duce outdoor air which mixes with the conditioned air, improving indoor air quality and often reducing energy consumption. During a first stage call for cooling, if the outdoor -air tempera- ture is below the economizer control changeover set point, the discharge -air sensor modulates the economizer outdoor -air damper open to take advantage of free cooling provided by the outside air. When second -stage cooling is called for, the com- pressor is energized in addition to the economizer. If the outdoor -air temperature is above the changeover set point, the first stage of compression is activated and the economizer stays at vent position. Durablade economizer operation is controlled by a dry-bulb thermostat that senses outdoor -air temperature. Accessory upgrade kits allow for either outdoor -air enthalpy changeover or for more precise differential enthlapy control. The Durablade economizer (option or accessory) on the 580D units has a reliable sliding plate damper which is easily adjusted for 100% outdoor air, 100% return air, or any proportions of mixed air. The 580D units can also utilize the field or factory -installed EconoMi$er. The EconoMi$er is microprocessor controlled and incorporates a parallel, opposed -blade damper system. In addi- tion, it has a spring return built into the damper actuator to pro- vide reliable close -on -power -loss. The EconoMi$er comes equipped with up to 90% barometric relief capability for high outdoor airflow applications. In addition, the EconoMi$er power exhaust accessory can be utilized to help maintain proper building pressure. For units without economizer, year-round ventilation is enhanced by a manual outdoor -air damper (ordered as an accessory or an option). The damper can be preset to admit up to 50% outdoor air. INDOOR -AIR QUALITY (IAQ) BEGINS WITH BRYANT ROOF- TOPS — Sloped condensate pans minimize biological growth in rooftop units in accordance with ASHRAE (American Society of Heating, Refrigeration, and Air Conditioning Engineers) Stan- dard 62. Two-inch filters with optional dirty filter indicator switch provide for greater particle reduction in the return air. The face - split evaporator coils improve the dehumidification capability of standard units, and enthlapy controls maximize building humid- ity control. Optional proportional reacting CO2 sensor is available with the EconoMi$er to aid IAQ benefits. TABLE OF CONTENTS Page Features/Benefits 1-2 Model Number Nomenclature 3 ARI Capacity Ratings 3,4 Physical Data 5-8 Options and Accessories 9,10 Base Unit Dimensions 11,12 Accessory Dimensions 13,14 Selection Procedure 15 580D — Packaged Rooftop Standard Efficiency Gas/Electric Unit Page Performance Data 16-38 Electrical Data 39,40 Typical Piping and Wiring 41 Controls 42,43 Application Data 44 Typical Wiring Schematic 45,46 Guide Specifications 47-49 MODEL NUMBER NOMENCLATURE 580D E V 090 180 C B Evaporator -Fan Motor Options A — Standard Motor and Drive B —Alternate Motor and/or Drive Voltage Designation J — 208/230-1-60 P — 208/230-3-60 E — 460-3-60 T — 575-3-60 Fuel and Control Type ✓ — Natural Gas/Direct Spark Ignition Nominal Tons 036 — 3 090 — 7-1/2 048 — 4 102 — 8-1/2 060 — 5 120 — 10 072 — 6 150 — 12-1/2 Gas Heat Input (Btuh) 074 — 72,000 180 — 180,000 115 — 115,000 224 — 224,000 125 — 125,000 250 — 250,000 150 — 150,000 *Contains high pressure, (loss -of -charge) low-pressure, and freeze protection cutout switches. NOTE: The example model number 558DEV090180CB designates a 71/2ton 460-3-60 volt gas/electric rooftop unit with 180,000 Btuh nat- ural gas heat, Durablade economizer and alternate drive. Factory -Installed Outdoor -Air and Other Upgrade Options A — Standard Unit C — Durablade Economizer H — 25% Manual Damper M — Durablade Economizer, Controls Upgrade Package*, and Condenser Coil Grille N — 25% Manual Damper, Controls Upgrade Package*, and Condenser Coil Grille T — Controls Upgrade Package* and Condenser Coil Grille P — EconoMi$er L — EconoMi$er and Controls Upgrade Package (for use with Alternate Motor and Drive) R — EconoMi$er and Control's Upgrade Package (for use with Standard Motor and Drive) K — EconoMi$er, Controls Upgrade Package, and Condenser ARI* CAPACITY RATINGS UNIT 580D NOMINAL TONS STANDARD CFM NET COOLING CAPACITY (Btuh) TOTAL kW SEERt SOUND RATING (Bels) Belt Drive Direct Drive 036 3 1200 35,000 4.0 10.0 9.7 8.1 048 4 1600 47,000 5.5 10.0 9.7 8.1 060 5 2000 57,000 6.7 10.0 9.7 8.1 See Legend and Notes on page 4 3 ARI* CAPACITY RATINGS (cont) UNIT 580D NOMINAL TONS STANDARD CFM NET COOLING CAPACITY (Btuh) TOTAL kW EER SOUND RATING (BeIs) IPLV 072 6 2100 72,000 8.0 9.0 8.1 ** 090 71/2 2800 85,000 9.6 8.9 8.7 9.35 102 81/2 3000 99,000 11.0 9.0 8.7 9.00 120 10 4000 117,000 13.0 9.0 8.8 9.35 150 121/2 4500 145,000 16.1 9.0 8.7 9.20 LEGEND BeIs - Sound Levels (1 bel = 10 decibels) db - Dry Bulb EER - Energy Efficiency Ratio IPLV - Integrated Part -Load Values SEER - Seasonal Energy Efficiency Ratio wb - Wet Bulb *Air Conditioning and Refrigeration Institute. tApplies only to units with capacity of 65,000 Btuh or less. **The IPLV applies only to two-stage cooling units. NOTES: 1. Rated in accordance with ARI Standards 210/240, latest revision (for sizes 036-120) or 360, latest revision (for size 150) and 270, latest revision. 2. ARI ratings are net values, reflecting the effects of circulating fan heat. 3. Ratings are based on: Cooling Standard: 80 F db, 67 F wb indoor entering -air temperature and 95 F db air entering outdoor unit. IPLV Standard: 80 F db, 67 F wb indoor entering -air temperature and 80 F db outdoor entering -air temperature. HEATING CAPACITIES AND EFFICIENCIES UNIT 580D HEATING INPUT (Btuh) Stage 2/Stage 1 OUTPUT CAPACITY (Btuh) TEMPERATURE RISE (F) AFUE (%) STEADY-STATE EFFICIENCY (%) CALIFORNIA SEASONAL EFFICIENCY (%) 036 074 -/ 72,000 59,200 25-55 80.0 80.0 77.2 036115 115,000/ 82,000 92,000 55-85 80.0 80.0 76.7 048 074 -/ 72,000 59,200 25-55 80.0 80.0 77.2 048 115 -/115,000 92,000 35-65 80.0 80.0 77.1 048 150 150,000/120,000 120,000 50-80 80.0 80.0 76.9 060 074 -/ 72,000 59,200 25-55 80.0 80.0 77.2 060 115 -/115,000 92,000 35-65 80.0 80.0 77.1 060 150 150,000/120,000 120,000 50-80 80.0 80.0 76.9 072 074 -/ 72,000 59,200 25-55 80.0 80.0 77.2 072 115 -/115,000 92,000 35-65 80.0 80.0 77.1 072 150 150,000/120,000 120,000 50-80 80.0 80.0 76.9 090 125 -/125,000 100,000 20-50 80.0 80.0 75.8 090 180 180,000/120,000 144,000 35-65 80.0 80.0 77.1 090 224 224,000/180,000 179,200 45-75 80.0 80.0 77.1 102 125 -/125,000 100,000 20-50 80.0 80.0 75.8 102 180 180,000/120,000 144,000 35-65 80.0 80.0 77.1 102 224 224,000/180,000 179,200 45-75 80.0 80.0 77.1 120 180 180,000/120,000 144,000 35-65 80.0 80.0 77.1 120 224 224,000/180,000 179,200 35-65 80.0 80.0 77.1 120 250 250,000/200,000 200,000 40-70 80.0 80.0 76.4 150 224 224,000/180,000 179,200 35-65 80.0 80.0 77.1 150 250 250,000/200,000 200,000 40-70 80.0 80.0 76.4 LEGEND AFUE - Annual Fuel Utilization Efficiency NOTE: NO, levels are 40 nanograms/joule with the accessory NO), reduction kit (sizes 036-060). 4 PHYSICAL DATA - 580D036-072 UNIT SIZE 580D 036 048 060 072 NOMINAL CAPACITY (tons) 3 4 5 6 OPERATING WEIGHT (Ib) Unit AUAI* 460 470 490 565 Al/Cu* 465 476 497 576 Cu/Cu* 468 482 505 587 Economizer Durablade 34 34 34 34 EconoMi$er 47 47 47 47 Roof Curbt 115 115 115 115 COMPRESSOR Reciprocating Reciprocating Reciprocating Scroll Quantity 1 1 1 1 No. Cylinders (per Circuit) 2 2 . 2 — Oil (oz) 50 50 50 54 REFRIGERANT TYPE R-22 Expansion Device Fixed Orifice Metering Device Operating Charge (lb -oz) Circuit 1 3-6 4-11 5-13 7-8 Circuit 2 — — — — CONDENSER COIL Enhanced Copper Tubes. Aluminum Lanced Fins Rows...Fins/in. 1...17 1...17 1...17 2...17 Total Face Area (sq ft) 7.36 11.39 13.19 10.42 CONDENSER FAN Propeller Type Nominal Cfm 3500 4000 4000 4000 Quantity...Diameter (in.) 1...22.0 1...22.0 1...22.0 1...22.0 Motor Hp...Rpm /4...1100 /4...1100 /4...1100 /4...1100 Watts Input (Total) 325 325 325 325 EVAPORATOR COIL Enhanced Copper Tubes. Aluminum Double -Wavy Fins Rows...Fins/iin. 2...15 2...15 3...15 4...15 Total Face Area (sq ft) 4.17 5.5 5.5 5.5 EVAPORATOR FAN Centrifugal Type Quantity...Size (in.) Std 1...10 x 10 1...10 x 10 1...11 x 10 1...10 x 10 Alt 1...10x10 1...10x 10 1...10x10 — Type Drive Std Direct Direct Direct Belt Alt Belt Belt Belt — Nominal Cfm 1200 1600 2000 2400 Maximum Continuous Bhp Std .34 .75 1.20 2.40 Alt 1.00 1.00 1.30/2.40** — Motor Frame Size Std 48 48 48 56 Alt 48 48 56 — Nominal Rpm High/Low Std 860/800 1075/970 1075/970 — Alt 1620 1620 1725 — Fan Rpm Range Std — — — 1070-1460 Alt 760-1000 835-1185 900-1300 — Motor Bearing Type Ball Ball Ball Ball Maximum Allowable Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Min/Max (in.) Std — — — 2.8/3.8 Alt 1.9/2.9 1.9/2.9 2.4/3.4 — Nominal Motor Shaft Diameter (in.) Std 1/2 1/2 1/2 5/8 Alt 1/2 1/2 5/8 Fan Pulley Pitch Diameter (in.) Std — — — 4.5 Alt 4.5 4.0 4.5 — Belt, Quantity...Type...Length (in.) Std — — — 1...A...40 Alt 1...A...34 1...A...34 1...A...39 — Pulley Center Line Distance (in.) Std — — — 14.7-15.5 Alt 10.0-12.4 10.0-12.4 14.7-15.5 — Speed Change per Full Turn of Std — — — 80 Movable Pulley Flange (rpm) Alt 48 70 80 — Movable Pulley Maximum Full Turns Std — — — 5 From Closed Position Alt 5 5 5 — Factory Setting Std — — — 3 Alt 3 3 3 — Factory Speed Setting (rpm) Std — — — 1225 Alt 856 975 1060 — Fan Shaft Diameter at Pulley (in.) 5/8 5/8 5/8 5/8 LEGEND Al — Aluminum Bhp — Brake Horsepower Cu — Copper *Evaporator coil fin materiaVcondenser coil fin material. Contact your local repre- sentative for details about coated fins. tWeight of 14 -in. roof curb. **Single-phase/three-phase. 5 II -Rollout switch lockout is manually reset by interrupting power to unit or resetting thermostat. II Requires an optional or accessory Controls Upgrade Kit. NOTE: The 580D150 units have a loss-of-charge/low-pressure switch (accessory or option) located in the liquid line. PHYSICAL DATA - 580D036-072 (cont) UNIT SIZE 580D FURNACE SECTION Rollout Switch Cutout Temp (F)7t Burner Orifice Diameter (in....drill size) Natural Gas Std Liquid Propane Alt Thermostat Heat Anticipator Setting (amps) 208/230 v and 575 Stage 1 Stage 2 460 v Stage 1 Stage 2 Gas Input (Btuh) Stage 1 Stage 2 Efficiency (Steady State) (%) Temperature Rise Range Manifold Pressure (in. wg) Natural Gas Std Liquid Propane Alt Gas Valve Quantity Gas Valve Pressure Range Psig in. wg Field Gas Connection Size (in.) HIGH-PRESSURE SWITCH (psig)II Standard Compressor Internal Relief (Differential) Cutout Reset (Auto.) LOW-PRESSURE SWITCH (psig)II Cutout Reset (Auto.) FREEZE PROTECTION THERMOSTAT (F)II Opens Closes OUTDOOR -AIR INLET SCREENS Quantity...Size (in.) RETURN -AIR FILTERS Quantity...Size (in.) 036 MEDIUM/HIGH HEAT 195 .113...33 .089...43 .14 .14 .14 .14 72,000/82,000 -/115,000 80 25-55/55-85 3.5 3.5 1 0.180-0.487 5.0-13.5 1/2 048 LOW/MEDIUM/HIGH HEAT 195 .113...33/.113...33/.129...30 .089...43/.089...43/.102...38 .14 .14 .14 .14 72,000/115,000/120,000 -/-/150,000 80 25-55/35-65/50-80 3.5 3.5 1 0.180-0.487 5.0-13.5 1/2 060 LOW/MEDIUM/HIGH HEAT 195 .113...33/.113...33/.129...30 .089...43/.089...43/.102...38 .14 .14 .14 .14 72,000/115,000/120,000 -/-/150,000 80 25-55/35-65/50-80 3.5 3.5 1 0.180-0.487 5.0-13.5 1/2 450* 50 428 320 072 LOW/MEDIUM/HIGH HEAT 195 .113...33/.113...33/.129...30 .089...43/.089...43/.102...38 .14 .14 .14 .14 72,000/115,000/120,000 -/-/150,000 80 25-55/35-65/50-80 3.5 3.5 1 0.180-0.487 5.0-13.5 1/2 500 ± 50 428 320 7±3 22 t7 30 t5 45 t5 Cleanable 1...20x24x1 Throwaway 2...16x25x2 LEGEND Al - Aluminum Bhp - Brake Horsepower Cu - Copper `Evaporator coil fin materiaVcondenser coil fin material. Contact your local repre- sentative for details about coated fins. tWeight of 14 -in. roof curb. "Single-phase/three-phase. 6 ttRollout switch lockout is manually reset by interrupting power to unit or resetting thermostat. II Requires an optional or accessory Controls Upgrade Kit. NOTE: The 580D150 units have a loss-of-charge/low-pressure switch (accessory or option) located in the liquid line. PHYSICAL DATA - 580D090-150 UNIT SIZE 580D 090 102 120 150 NOMINAL CAPACITY (tons) 71/2 81/2 10 121/2 OPERATING WEIGHT (Ib) Unit Al/AI* 870 880 1035 1050 Al/Cu* 881 896 1057 1077 Cu/Cu* 893 907 1080 1100 Economizer Durablade 44 44 44 44 EconoMi$er 62 62 62 62 Roof Curbt 143 143 143 143 COMPRESSOR Reciprocating Reciprocating ' Reciprocating Scroll Quantity 2 2 2 2 No. Cylinders (per Circuit) 2 2 2 - Oil (oz) 42 ea 65 ea 54 ea 54 ea REFRIGERANT TYPE R-22 Expansion Device Fixed Orifice Metering Device Operating Charge (Ib -oz) Circuit 1 4-13 6-14 7- 3 8-10 Circuit 2 4-14 9- 2 7-13 8- 6 CONDENSER COIL Enhanced Copper Tubes. Aluminum Lanced Fins Rows...Fins/in. 1...17 2...17 2...17 2...17 Total Face Area (sq ft) 20.50 18.00 20.47 25.00 CONDENSER FAN Propeller Type Nominal Cfm 6400 6400 7000 7000 Quantity...Diameter (in.) 2...22 2...22 2...22 2...22 Motor Hp...Rpm /4...1100 /4...1100 /4...1100 1/4...1100 Watts Input (Total) 600 600 600 600 EVAPORATOR COIL Enhanced Copper Tubes. Aluminum Double -Wavy Fins Rows...Fins/in. 3...15 3...15 3...15 4...15 Total Face Area (sq ft) 8.0 8.0 10.0 11.1 EVAPORATOR FAN Centrifugal Type Quantity...Size (in.) Std 1...15 x 15 1...15 x 15 1...15 x 15 1...15 x 15 Alt 1...15x15 - 1...15x15 1...15x15 Type Drive Std Belt Belt Belt Belt Alt Belt - Belt Belt Nominal Cfm 3000 3100 4000 5000 Maximum Continuous Bhp Std 2.40 2.40 2.40 3.70 Alt 2.40 - 2.90 5.25 Motor Frame Size Std 56 56 56 56 Alt 56 - 56 56 Nominal Rpm High/Low Std - - - - Alt - - - - Fan Rpm Range Std 590-840 685-935 685-935 860-1080 Alt 685-935 - 835-1085 900-1260 Motor Bearing Type Ball Ball Ball Ball Maximum Allowable Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Min/Max (in.) Std 2.4/3.4 2.8/3.8 2.8/3.8 4.0/5.0 Alt 2.8/3.8 - 3.4/4.4 3.1/4.1 Nominal Motor Shaft Diameter (in.) Std 5/8 5/8 5/8 7/e Alt 1/2 - 7/e 7/8 Fan Pulley Pitch Diameter (in.) Std 7.0 7.0 7.0 8.0 Alt 7.0 - 7.0 5.9 Belt, Quantity...Type...Length (in.) Std 1...A...49 1...A...49 1...A...49 1...A...52 Alt 1...A...49 - 1...A...49 1...BX...46 Pulley Center Line Distance (in.) Std 16.75-19.25 16.75-19.25 15.85-17.50 15.85-17.50 Alt 16.75-19.25 - 15.85-17.50 15.85-17.50 Speed Change per Full Turn of Std 50 50 50 44 Movable Pulley Flange (rpm) Alt 50 - 50 50 Movable Pulley Maximum Full Turns Std 5 5 5 5 From Closed Position Alt 5 - 5 6 Factory Setting Std 5 5 5 5 Alt 5 - 5 5 Factory Speed Setting (rpm) Std 590 685 685 860 Alt 685 - 835 960 Fan Shaft Diameter at Pulley (in. 1 1 1 1 LEGEND Al - Aluminum Bhp - Brake Horsepower Cu - Copper *Evaporator coil fin materiaVcondenser coil fin material. Contact your local repre- sentative for details about coated fins. 1 -Weight of 14 -in. roof curb. 7 **Rollout switch lockout is manually reset by interrupting power to unit or resetting thermostat. ttRequires an optional or accessory Controls Upgrade Kit. NOTE: The 580D150 units have a loss-of-charge/low-pressure switch (accessory or option) located in the liquid line. PHYSICAL DATA - 580D090-150 (cont) UNIT SIZE 580D FURNACE SECTION Rollout Switch Cutout Temp (9.. Burner Orifice Diameter (in....drill size) Natural Gas Liquid Propane Thermostat Heat Anticipator Setting (amps) 208/230 v and 575 Stage 1 Stage 2 460 v Stage 1 Stage 2 Gas Input (Btuh) Stage 1 Stage 2 Efficiency (Steady State) (%) Temperature Rise Range Manifold Pressure (in. wg) Natural Gas Liquid Propane Gas Valve Quantity Gas Valve Pressure Range Psig in. wg Field Gas Connection Size (in.) Std Alt Std Alt HIGH-PRESSURE SWITCH (psig)tt Standard Compressor Internal Relief (Differential) Cutout Reset (Auto.) LOW-PRESSURE SWITCH (psig)tt Cutout Reset (Auto.) FREEZE PROTECTION THERMOSTAT (F)tt Opens Closes OUTDOOR -AIR INLET SCREENS Quantity...Size (in.) RETURN -AIR FILTERS Quantit ...Size (in. 090 LOW/MEDIUM/HIGH HEAT 195 .120...31 .096...41 .14 .20 .14 .20 125,000/120,000/180,000 -/180,000/224,000 80 20-50/35-65/45-75 3.5 3.5 1 0.180-0.487 5.0-13.5 1/2/3/4/3/4 102 LOW/MEDIUM/HIGH HEAT 195 .120...31 .096...41 .14 .20 .14 .20 125,000/120,000/180,000 -/180,000/224,000 80 20-50/35-65/45-75 3.5 3.5 1 0.180-0.487 5.0-13.5 1/2/3/4/3/4 120 LOW/MEDIUM/HIGH HEAT 195 .096...41/.096...41/.102...38 .14 .20 .14 .20 120,000/180,000/200,000 180,000/224,000/250,000 80 35-65/35-65/40-70 3.5 3.5 1 0.180-0.487 5.0-13.5 3/4/3/4/3/4 450 t 50 428 320 150 LOW/MEDIUM HEAT 195 .120...31/.129...30 .096...41/.102...38 .14 .20 .14 .20 180,000/200,000 224,000/250,000 80 35-65/40-70 3.5 3.5 1 0.180-0.487 5.0-13.5 3/4/3/4 500 ± 50 428 320 7 t 3 22 t7 30 t5 45 t5 Cleanable 1...20x24x1 1...16x25x1 4...16 x 20 x 2 Throwaway 4...16x20x2 ,4...20x20x2 4...20x20x2 LEGEND Al - Aluminum Bhp - Brake Horsepower Cu - Copper *Evaporator coil fin materiaVcondenser coil fin material. Contact your local repre- sentative for details about coated fins. tWeight of 14 -in. roof curb. 8 **Rollout switch lockout is manually reset by interrupting power to unit or resetting thermostat. 11 -Requires an optional or accessory Controls Upgrade Kit. NOTE: The 580D150 units have a loss-of-charge/low-pressure switch (accessory or option) located in the liquid line. OPTIONS AND ACCESSORIES ITEM OPTION* ACCESSORY'!" EconoMi$er X X EconoMi$er with Power Exhaust X Power Exhaust for EconoMi$er X Durablade Integrated Economizer (Includes Hood) X X Manual Outdoor -Air Damper X X Controls Upgrade Kit** X X Alternate Drive (090) X Alternate Motor and Drive (036-060,102,150) X LP (Liquid Propane) Conversion Kit X Electronic Programmable Thermostat X 25% Open Two -Position Damper X 100% Open Two -Position Damper X Roof Curbs (Vertical and Horizontal Discharge) X Thermostats and Subbases X Motormaster® IV Head Pressure Control (Cycle Control) X Time Guard® II Control Circuit X Thru-the-Bottom Service Connections X AccusensorTM II Enthalpy Control X Accusensor III Enthalpy Sensor X Condenser Coil Grille X X Condenser Coil Hail Guard Assembly X Flue Shield X NO, Reduction Kit (036-060)tt X Flue Discharge Deflector X Fan/Filter Status X Outdoor Air Enthalpy Sensor (EconoMi$er Only) X Return Air Enthalpy Sensor (EconoMi$er Only) X Return Air Temperature Sensor (EconoMi$er Only) X Indoor Air Quality (CO2) Sensor (EconoMi$er Only) X *Factory -installed. tField-installed. **Includes high-pressure, low-pressure/loss-of-charge, and freeze protection switches. ttAllows the unit to meet the California Air Quality Management Districts NO, requirement of 40 nanograms/joule or less. NOTE: Refer to 580D price pages or contact your local representative for accessory/and option package information. Low Ambient Controls The 580D standard units are designed to operate in cooling at outdoor temperatures down to 25 F. With accessory Motormaster IV control (condenser -fan cycling) units can operate at outdoor temperatures down to —20 F. The head pressure controls, which mount in the condenser section, control the condenser -fan motor to maintain correct condensing temperature. MOTORMASTER IV CONTROL Bryant Commercial Programmable Thermostat Designed specifically for use with Bryant commercial sys- tems, this Bryant programmable thermostat features LED occupied/unoccupied displays and setback mode which can override continuous fan operation. Time Guard II Control Time Guard II control automatically prevents compressor from restarting for at least 5 minutes after a shutdown. Accessory prevents short cycling of compressor if thermostat is changed rapidly. Time Guard II control mounts in the control compart- ment of unit. 9 OPTIONS AND ACCESSORIES (cont) 036-072 SHOWN Liquid Propane (LP) Conversation Kits The LP conversion kit allows the unit to utilize a liquid propane fuel supply in areas where natural gas is unavailable, and permits the unit to be converted from natural gas to LP gas use. The kit contains the orifices required for LP operation. ECONOMI$ER CONTROLLER GEAR -DRIVEN PLUG ACTUATOR DAMPER OUTDOOR AIR TEMPERATURE SENSOR BAROMETRIC RELIEF DAMPERS EconoMi$er Factory -installed EconoMi$er utilizes a microprocessor -based con- trol, gear drive damper system, low pressure drop characteristics, built-in spring return (for close upon power loss), and an integral barometric damper. NOTE: EconoMi$er is only available for vertical ductwork applica- tions and can be field or factory installed. 0 61+ Ir. -=--Nimgollkul1111' Awaikasocas laleasimaa 0 0 0 cOs Durablade Economizer Exclusive Durablade economizer damper design saves energy while providing economical and reliable cooling. A sliding plate on the face of the economizer controls the amount of outdoor air entering the system. Closed, it provides a leakproof seal which prevents ambient air from seeping in or conditioned air from seeping out. It can be adjusted easily for 1 00% outdoor air or any proportions of mixed air. Like the base unit, the economizer is converted easily for horizontal discharge applications. Accusensor 111 Sensor AccusensorTM II Control Accusensor economizer controls help provide efficient, economical economizer operation. Accusensor II solid-state enthalpy control includes the logic and one sensor to calculate both dry- and wet - bulb of the outdoor air to provide an accurate enthalpy reading. It then decides when to energize the economizer based on this read- ing. Accusensor III sensor (required for all units for differential enthalpy sensing) compares outdoor temperature and humidity to return -air temperature and humidity and determines the most eco- nomical mixture of air (purchased in addition to enthalpy control for differential enthalpy sensing). 10 BASE UNIT DIMENSIONS - 580D036-072 UNIT 580D STANDARD UNIT WEIGHT DURABLADE ECONOMIZER WEIGHT ECONOMISER WEIGHT CORNER WEIGHT A) CORNER WEIGHT (B CORNER WEIGHT C) CORNER WEIGHT D) Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg 036 460 209 34 15.4 47 21.3 140 63.5 105 47.6 159 72.1 56 25.4 048 470 213 34 15.4 47 21.3 142 64.4 106 48.1 162 73.5 60 27.2 060 490 222 34 15.4 47 21.3 150 68.0 115 52.2 160 72.6 65 29.5 072 565 256 34 15.4 47 21.3 165 74.8 136 61.7 200 90.7 64 29.0 NOTES: 1. Dimensions in [ ] are in millimeters. 2. Center of gravity. 3. %% Direction of airflow. BOTTOM POWER CHART, THESE HOLES REQUIRED FOR USE WITH ACCESSORY PACKAGES - CRBTMPWROO1A00, (POWER AND CONTROL) AND CRBTMPWR003A00 (POWER, CONTROL, AND GAS) THREADED CONDUIT SIZE CONNECTION SIZES A 11/18" Dia [27] Field Power Supply Hole B 3/4"-14 NPT Condensate Drain C 1/2"-14 NPT Gas Connection NOTES: 1. Dimensions in [ ] are in millimeters. 2. Center of gravity. 3. %% Direction of airflow. BOTTOM POWER CHART, THESE HOLES REQUIRED FOR USE WITH ACCESSORY PACKAGES - CRBTMPWROO1A00, (POWER AND CONTROL) AND CRBTMPWR003A00 (POWER, CONTROL, AND GAS) THREADED CONDUIT SIZE WIRE USE REQURED HOLE SIZES (MAX.) 1/2 24 V 7/8' [22.2] 3/4' Power 11/8' [28.4] 1/2" FPT Gas 11/4" [31.8] 0'-1 13/16" [46.5] 0'-1 5/8" [41] 1'-0' [305] CONTROL BOX ACCESS PANEL / 0' L8' [203] 4. On vertical discharge units, ductwork to be attached to accessory roof curb only. For horizontal dis- 2'-9 5/16' charge units, field -supplied flanges should be attached to horizontal discharge openings, and all [846.5] ductwork should be attached to the flanges. 5. Minimum dearanoe (local codes or jurisdiction may prevail): BOTTOM OF UNIT a. Between unit, flue side and combustible surfaces, 36 inches. b. Bottom of unit to combustible surfaces (when not using curb), 1 inch. Bottom of base rail to combustible surfaces (when not using curb) 0 inches. c. Condenser coil, for proper airflow, 36 in. one side, 12 in. the other. The side getting the greater clearance is optional. d. Overhead, 60 in. to assure proper condenser fan operation. o' -4 9/16" e. Between units, control box side, 42 in. per NEC. f. Between unit and ungrounded surfaces, control box side, 36 in. per NEC. g. Between unit and block or concrete walls and other grounded surfaces, control box side, 42 in. per NEC. h. Horizontal supply and retum end, 0 inches. 6. With the exception of the clearance for the condenser coil and combustion side as stated in notes 5a, b and c, a removable fence or barricade requires no clearance. 7. Units may be installed on combustible floors made from wood or Class A, B, or C roof covering material if set on base rail. 8. The vertical center of gravity is 1'-6" [457] up from the bottom of the base rail. [843] 16" CORNER 3' 1 1/2' [952.5] CONDENSER COIL REAR COMPRESSOR - ACCESS COVER SEE NOTE .8 OUTSIDE AIR 2'-5 5/8' [751.61.6 y, F/ ECONOMISER AND 4 POWER EXHAUST 5 2'-0 15/16' [633]0 -4 1/2 F/ DURABLADE ECON x[114] ECONOMIZER HOOD CORNER LEFT SIDE 3-9" [1144] lit 111 111 ISI 11 / �0'-3 7/8' 2'-1/2" d1 2 1. 2' 1/4' [99]- [622] II SEE IIVIEW A -A/ 0'-1 7/8- 0 -11 1/2' \ _[44.5] [290] 6 [115.8] 3' 5 3/16" TYP [1046] 0'-2 9/16" LED VIEW HOLE [65] LEFT SIDE BLOCKOFF FLUE HOOD FILTER ACCESS PANEL (DISPOSABLE FILTERS) 1 1.1 PANEL CHANNEL FOR [2-3/4- CONTROL MIRING65 �I 1'-4 3/8' [416] F/ DURABLADE ECON 1'-6 1/8' [460] F/ ECONOMISER AND POWER EXHAUST 2' 1 11/16" L0'-3 3/16' [652] [81] RETURN -AIR OPENING VERTICAL 1'457431/16' VIEW A -A 0.-10 115/16' 6022 RETURN AIR [278] b6-0'-5 3/8' [137] d RIGHT SIDE IAALT. CONDENSATE DRAIN / EVAPORATOR COIL r-0'-1 15/16" [49] 0'-3 5/16" [99.4] SUPPLY -AIR OPENING VERTICAL L-0'-2 5/16' [58] X0'-2 9/16" [65] 1'-5 3/4' [451] CORNER 'D" SEE BOTTOM POWER CHART(ELEC. ONLY) CONTROL BOX ACCESS PANEL 2'-11 11/16' +I [906] 2' 5 5/16' [744] CONTROL 80X ACCESS PANEL FRONT 0'-3 1/16" [78] 6'-1 11/16' [1872] 0 [306] 0'-5 7/16' [138] ._0.-3 3/16' ----CORNER "C' tr[81) SUPPLY AIR SUGGESTED ELECTRICAL DISCONNECT AREA EVAPORATOR -FAN MOTOR 6 BLOWER ACCESS PANEL 0'-0 3/8" [1 03 1G' -ll 7/8' 2 53/8 [746.2] / BURNER ACCESS PANEL [301.6] FORK TRUCK SLOTS 0'-5 3/4' 0'-7 3/8"[146] [188.0] 0'-2 1/4-D1A OUT IDE [57] OF PANEL (TYP 8 PLACES) 1'-5 5/16' [439.7] FRONT 0'-7 1/4" [184] '-10 13/16' [274.6] Ido 0 0'-l0 1/2' [266.7] 1'-2 1/2' [368.3] VIEW S -S 0'- 0 7/8' [22 2] ECONOMISER 0'-2 3/4" [72] -I ECONOMISER 0'-4 1/16' W/ POWER EXHAUST [103.2] FILTER ACCESS PANEL (DISPOSABLE FILTERS) 2'-1 1/16" RETURN - AIR OPENING HORI- ZONTAL I 7' [177.8] [652.5] HOOD FILTER 338.87 4' OUTSIDE AIR 0'-8 1/8' [206.2) 2'-1 15/16'. �%. f0.-5 11/16' [658.6] SUPPLY AIR RETURN AIR [144.3] RIGHT SIDE B STD. CONDENSATE DRAIN 11 BASE UNIT DIMENSIONS - 580D090-150 12 UNIT STANDARD UNIT WEIGHT DURABLADE ECONOMIZER WEIGHT ECONOMISER WEIGHT CORNER WEIGHT (A) CORNER WEIGHT (B) CORNER WEIGHT (C) CORNER WEIGHT (D) "H" "J" "K" "L" SBOD Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg ftdn. [mm] ft -In. [mm] ft -In. [mm] ft -in. [mm] 090 870 395 44 20 62 28 189 86 161 73 239 109 280 127 1-27/8 [ 378] 3.55/16 [1050] 2-911/16 [856] 2- 27/16 [672] 102 880 399 44 20 62 28 191 87 163 74 242 110 284 129 3-37/8 [1013] 3-56/16 [1050] 2-911/16 [856] 2- 27/16 [672] 120 1035 469 44 20 62 28 225 102 192 87 285 129 333 151 2-57/8 [ 759] 4.15/16 [1253] 3-03/6 [924] 2-107/16 [875] 150 1050 476 44 20 62 28 228 103 195 88 289 131 338 153 1-27/8 [ 378] 4.15/16 [1253] 3.03/8 [924] 2-107/16 [875] NOTES: CONNECTION SIZES BOTTOM POWER CHART, THESE HOLES REQUIRED FOR USE WITH ACCESSORY PACKAGES — 1. Dimensions in [ ] are in millimeters. A 13/e Dia [35] Field Power Supply Hole CRBTMPWROO2A00 (POWER AND CONTROL) 2. Center of gravity. B 21/2" Dia [64] Power Supply Knodcout AND CRBTMPWROO4A00 (POWER, CONTROL, AND GAS) C 13/4 Dia [44) Charging Port Hole THREADED WIRE REOURED 3. Zf' Direction of airflow.7 " CONDUIT SIZE USE HOLE SIZES (MAX.) D /8 Dia [22] Field Control Wiring Hole t/z" 7/8'1222] 4. On vertical discharge roof curb only. units, For horizontal ductwork to be attached t0 accessory discharge units, field -supplied E O /4 =14 NPT Condensate Drain 11/4" 24 V Power 13/4 [44.4] flanges should be all ductwork should attached be attached to horizontal discharge openings, and to the flanges. F 1/2"-14 NPT Gas Connection 580D090 125 and /4"-14 NPT Gas Connection All Other Units 102 125 3/4 FPT Gas 16/4 [41.3] 5. Minimum clearance a. Between unit, (local flue side codes or Jurisdiction may prevail): and combustible surfaces, 36 inches. G 2" Dia [51] Power Supply Knockout "• b. Bottom of unit 1 inch. Bottom of base to combustible rail to surfaces (when not using curb),. combustible surfaces (when not using p & - O'-7 3/8" (187] 0'-3 13/16' curb) 0 inches. c. Condenser coil, other. The side for proper getting airflow, 36 In. one side, 12 in. the the greater clearance is optional. —_ I C97' B d. Overhead, 601n. e. Between units, f. Between unit 36 In. per NEC. g. Between unit surfaces, control h. Horizontal supply 6. With the exception to assure control and ungrounded and block box and of the proper condenser fan operation. box side, 42 in. per NEC. surfaces, control box side, -J' or concrete walls and other grounded side, 42 In. per NEC. retum end, 0 inches.ure clearance for the condenser coil and js'4 • UT CONDENSER COIL `I h FLUE HOOD A 6 2'-0 3/8' (619] D , combustion side as stated in notes 5a, b and c, a removable fence . or barricade requires no dearance. ill". �� " 7. Units may be Installed Class A, B, or C 8. The vertical center on roof covering of gravity combustible floors made from wood or material if set on base rail. 0'-4 9/16•wTra Is 1'-7" [483] for 090 and 102, 1'-11" (116] °F hug RAIL 4'-5 7/B' - 0'-5 3/4" (146] 1584) for 120 and 150 up from the bottom of the base rall.0'-2 9/16" - C65] TYP - (1369' LEFT SIDE — ELECTRI CAL DISCONNECT LOCATION FILTER ACCESS PANEL (DISPOSABLE FILTERS) S S —5 1/2' REAR r 0'-3 9/16" [902] - " FILTER/ECONOMIZER CONDENSER COIL ACCESS PANEL OUTSIDE AIR (90) FrCORNER 'B' • , /1'-5 3' 6 15/16" C1091] 7/8" [454] F/ DURABLADE ECON ECONOMIZE oH03D (609.6POWER 2 16 O CORNER "A' \\ 1/8" C791< F/ ECO' -O' EX. 6 BLOCKOFF VIEW S -S 0'-5 1/t" PANEL IIS . EVACPOORLK [140)4 4 RETURVERTICALENING L 07TOR[' ' ' [32/8" A*y0S b RETURN AIR b ° — — — --I t11001O C266 �7]2 4'-9 3/4' IE1 C1467] ALT. CONDENSATE r — — 4 [ 0'-2 9/16" 0'-2 13/16" [65J (71.5] 0'- 0 7/8" (22 2] LEFT [) . DRAINN OPENING 1 SUPPLY AIR I I 2'-4 3/4" ECONOMISER SIDE [[ ''-[,1/] OPENING IVERT[CALI I C730] RIGHT SIDE 1'1 1/4". (591] 0'-9 7/8" 0'-1 15/16"0'-4 SEE NOTE .8 11/16" I i, SUPPLY AIR (� - (1207 C251; ] (48.5] " — --1 1'-2 1/2' (368.3] CORNER "D" / SEE BOTTOM POWER CHART (ELE[. ONLY) z 74 .789 [731.8] 3'-6 1/4" I —� FRONT b 1'-2" [355] -8 3/16 0"-5 7/16" [138] 0'-3 1/8" CORNER "C" (79] ISI —8 0'-2 3/4" (72] ECONOMItiER [10737 ...Q' (208] M/ POWER EXHAUST - 3' 4 1/4"—.I [10227 7'-3 3/8' (2219] 0'-0 3/8" (10] rr - 0'-7 5/16"- (185] - 2'-4 5/16" - C719] - - - 0.-4 " (101] —1'-0 5/8" (3203 FILTER ACCESS PANEL CONTROL BOX/ "L" , INDOOR -FAN MOTOR 6 — RETURN- AIR /(DISPOSABLE FILTERS) "K' HOOD FILTER COMPRESSOR/ BURNER ACCESS BLOWER ACCESS PANEL OPENING HORIZONTAL�� PANEL OUTSIDE AIR 1'-1 7/8" SUPPLY -AIR OPENING% 2'-2 7/16" 0'-3 5/16' [352] HORIZONTAL— [671_S (91] F � J 0 _ - o o r_�f•1��=0I': I I� . (179]16 3'-0' 3'-1" ' 0'-7' 0'-5 11/16 (914.4] FORK TRUCK SLOTS OUTSIDE 0.-8 1 ]7/16' 0(TYP 8 PLACES) PANEL FRONT C940] (178] [1441 % �% RIGHT SIDE SUPPLY AIR RETURN AIR E STD. CONDENSATE DRAIN 12 r,71-5I2flaWNS HVAC Equipment Submittal Data For Review and Approval 08/15/2016 Project Info Project Name: OFFICE DEPOT Submitted By Contractor: Name: Address: Phone: Email: FIVE STAR MECHANICAL CHRIS CHORNYAK 109 WASHINGTON BLVD #B ALGONA, WA 98001 253-852-8284 CHRIST@FIVESTARMECH.COM Certifications: Daikin brand heating and cooling units are certified as follows: - AHRI Certified - ETL & CETL Listed - GAMA Certified Limited Warranty: - 5 year parts limited warranty - 20 year heat exchanger limited warranty - Complete warranty details attached Daikin North America, LLC is not responsible for products installed outside the United States or its territories, or Canada. REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2017 City of Tukwila BUILDING DIVISION Vt(7003O RECEIVED CITY OF TUKWILA MAR 03 2017 PERMrr CENTER Page 1 of 8 Project: OFFICE DEPOT Table of Contents System ID Description Page 580DEV150220AA REPL DCG1502104BAXX Performance 3 Dimensional Drawings 580DEV150220AA REPL DCG090-150 Physical Dimensions 4 Accessories 580DEV150220AA REPL DDNECNJ90150B Economizer 5 Limited Warranty 6 Page 2 of 8 Project: OFFICE DEPOT System ID(s): 580DEV150220AA REPL Design Requirements Power Supply Cooling Capacity Outdoor Design Temp Indoor Dry Bulb Temp Indoor Wet Bulb Temp Total CFM ESP Configuration 480/3/60 12.5 Ton 95.0 80.0 67.0 4975 0.6. Downflow Standard Features: DC Series Packaged Units - R -410A chlorine -free refrigerant - High -efficiency Copeland scroll compressor(s) - Copper tube / aluminum fin coils - High-capacity, steel -cased filter dryer - High- and Low-pressure switches - Lugged electrical contactor - Single -point power - Color Coded Wiring - Foil Faced Internal Insulation Heavy -gauge, galvanized -steel cabinet - UV -resistant powder -paint finish - Full perimeter base rail MODEL #: DCG1502104BAXX Cooling Performance Total Capacity 148.0 MBH Sensible Capacity 106.0 MBH Cooling Stages Two Refrig Type R410A Compressor Type Copeland Scroll Pressure Switches High & Low (std) Outdoor Design Temp 95.0 Indoor Dry Bulb Temp 80.0 Indoor Wet Bulb Temp 67.0 Efficiency (at ARI conditions) 10.8 EER / 11.0 IEER Heating Performance Input 210000 Hi, 157500 Lo Output 168000 Hi, 126000 Lo AFUE 80% Supply Air Blower Performance Total Air Supply ESP Blower Type Horsepower Base Unit Electrical Data Power Supply Min Circuit Ampacity Max Overcurrent Protection Physical Attributes Base Unit Oper. Weight (lbs) Decibels Filter(s) 4975 CFM 0.6 IWG Belt Drive 3 480/3/60 31 Amps 40 Amps 1365 83 Qty (4) 20x25x2 FId Inst . Fct Inst Item # Y DDNECNJ90150B Accessories Description Downflow Economizer Dimensions lbs 40x20x41 135 Page 3 of 8 Project: OFFICE DEPOT DIMENSIONS System ID(s): 580DEV150220AA REPL L \ %" NPT Gas Pipe Entrance; 53%" 6 %" from bottom of rail 61'/" 12%" ii 5%" 28%" 73/" Return 36W 13W Supply 00 00 6%" MODEL SIZE 731 to lO Tons 1231 Tons Horizontal Discharge DIMENSIONS H 1 52%8" 99%" 58%8" 99318" Vertical Discharge (Bottom of Unit) Page 4 of 8 Project: OFFICE DEPOT System ID(s): 580DEV150220AA REPL Submittal Data: DDNECNJ90150 Economizer SPECIFICATIONS •Economizer installs internal to Packaged Roof Top Unit •100%Fully Modulating Dampers can allow up to 100% outside air •Honeywell Economizer Controls including: W7220 JADE Digital Economizer Module w/ Backlit LED Display & Diagnostic Capabilities C7400S Outdoor Air Enthalpy Sensor C7250A Mixed Air Discharge Sensor •Honeywell MS7105K Damper Actuator •Adjustable Minimum O/A Damper Position •Integral Barometric Relief Damper •Hoods are painted to match unit •Factory Wired Page 5 of 8 VDAIKIv COMMERCIAL WARRANTY Models: DCC, DCG, DCH, DTC, DTG, DTH • Damage or failure of the unit to start due to interruption in electrical service or inadequate electrical service. • Any damage caused by frozen or broken water pipes in the event of equipment failure. • Changes in the appearance of the unit that do not affect its performance. • Replacement of fuses and replacement or resetting of circuit breakers. Who Is Providing The Warranty? This warranty is provided to you by Daikin Company, L.P. ("Daikin"), which warrants all parts of this heating or air conditioning unit, as described below. Who Does This Warranty Cover? This warranty only covers the original owner of the non-residential building as of the installation date (as defined below) ("owner"). To What Type Of Installations Does This Warranty Apply? This warranty applies to heating and air conditioning units installed in buildings other than residences. Different warranties apply to units installed in owner -occupied residences and in multi- family residences not occupied by the owner. What Units Does This Warranty Not Cover? This warranty does not apply to: Units that are ordered over the Internet, by telephone, or by other electronic means unless the unit is installed by a dealer adhering to all applicable federal, state, and local codes, policies, and licensing requirements. Units that are installed outside the United States, its territories, or Canada. Units that are operated in incomplete structures. Units that are installed in residential buildings. What Problems Does This Warranty Cover? This warranty covers defects in materials and workmanship that appear under normal use and maintenance. Other Warranties THIS WARRANTY IS PROVIDED IN LIEU OF ANY OTHER WARRANTIES, WHETHER BY DAIKIN OR ANY OF ITS AFFILIATES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FORA PARTICULAR PURPOSE. What Problems Does This Warranty Not Cover? Daikin is not responsible for: Damage or repairs required as a consequence of faulty installation or application. Damage as a result of floods, fires, winds, lightning, accidents, corrosive atmosphere, or other conditions beyond Daikin's control. Damage or the need for repairs arising from the use of components or accessories not compatible with this unit. Normal maintenance as described in the installation and operating manual, such as cleaning of the coils, filter cleaning and/or replacement, and lubrication. Parts or accessories not supplied or designated by the manufacturer. Damage or the need for repairs resulting from any improper use, maintenance, operation, or servicing. Damage or the need for repairs resulting from the use of unapproved refrigerant types or used or recycled refrigerant. When Does Warranty Coverage Begin? Warranty coverage begins on the "installation date." The installation date is one of two dates: (1) The installation date is the date that the unit is originally installed. (2) If the date the unit is originally installed cannot be verified, the installation date is three months after the manufacture date. The first four digits of the serial number (YYMM) on the unit indicate the manufacture date. For example, a serial number beginning with "1306" indicates the unit was manufactured in June 2013. How Long Does Warranty Coverage Last? The warranty lasts for a period up to (1) 20 YEARS for the heat exchanger (only applicable to units containing a heat exchanger) and (2) 5 YEARS on all other parts. This warranty period does not continue after the unit is removed from the location where it was originally installed. The replacement of a part under this warranty does not extend the warranty period. In other words, Daikin warrants a replacement part only for the period remaining in the applicable warranty that commenced on the installation date. What Will Daikin Do To Correct Problems? Daikin will furnish a replacement part, without charge for the part only, to replace any part that is found to be defective due to workmanship or materials under normal use and maintenance. Furnishing of the replacement part is Daikin's only responsibility under this warranty. THE OWNER AGREES THAT THESE REMEDIES ARE THE OWNER'S EXCLUSIVE REMEDIES FOR BREACH OF ALL WARRANTIES. What Won't Daikin Do To Correct Problems? Daikin will not pay for: • Labor, freight, or any other cost associated with the service, repair, or operation of the unit. Part No. PWDLCPPF 7/2015 © 2014 - 2015 DAIKIN COMPANY. L.P. Page 6 of 8 V1J'AI1IN COMMERCIAL WARRANTY Models: DCC, DCG, DCH, 4. • Electricity or fuel costs, or increases in electricity or fuel costs, for any reason, including additional or unusual use of supplemental electric heat. • Lodging or transportation charges. • Refrigerant. WHETHER ANY CLAIM IS BASED ON NEGLIGENCE OR OTHER TORT, BREACH OF WARRANTY OR OTHER BREACH OF CONTRACT, OR ANY OTHER THEORY, NEITHER DAIKIN NOR ANY OF ITS AFFILIATES SHALL IN ANY EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOST PROFITS, LOSS OF USE OF A UNIT, EXTRA UTILITY EXPENSES, OR DAMAGES TO PROPERTY. How Can The Owner Receive Warranty Service? If there is a problem with the unit, contact a licensed contractor. To receive a replacement part, a licensed contractor must bring the defective part to a Daikin heating and air conditioning products distributor. For more information about the warranty, contact Daikin Consumer Affairs at 855-770-5678 or write to Daikin Consumer Affairs, 7401 Security Way, Houston, Texas 77040. Where Can Any Legal Remedies Be Pursued? ARBITRATION CLAUSE. IMPORTANT. PLEASE REVIEW THIS ARBITRATION CLAUSE. IT AFFECTS YOUR LEGAL RIGHTS. 1. Parties: This arbitration clause affects your rights against Daikin and any of its affiliates or employees or agents, successors, or assigns, all of whom together are referred to below as "we" or "us" for ease of reference. 2. ARBITRATION REQUIREMENT: EXCEPT AS STATED BELOW, ANY DISPUTE BETWEEN YOU AND ANY OF US SHALL BE DECIDED BY NEUTRAL, BINDING ARBITRATION RATHER THAN IN COURT OR BY JURY TRIAL. "Dispute" will be given the broadest possible meaning allowable by law. It includes any dispute, claim, or controversy arising from or relating to your purchase of this heating or air conditioning unit, any warranty upon the unit, or the unit's condition. It also includes determination of the scope or applicability of this Arbitration Clause. The arbitration requirement applies to claims in contract and tort, pursuant to statute, or otherwise. 3. CLASS -ARBITRATION WAIVER: ARBITRATION IS HANDLED ON AN INDIVIDUAL BASIS. IF A DISPUTE IS ARBITRATED, YOU AND WE EXPRESSLY WAIVE ANY RIGHT TO PARTICIPATE AS A CLASS REPRESENTATIVE OR CLASS MEMBER ON ANY CLASS CLAIM YOU MAY HAVE AGAINST US OR WE AGAINST YOU, OR AS A PRIVATE ATTORNEY GENERAL OR IN ANY OTHER REPRESENTATIVE CAPACITY. YOU AND WE ALSO WAIVE ANY RIGHT TO CLASS ARBITRATION OR ANY CONSOLIDATION OF INDIVIDUAL ARBITRATIONS. Page 7 of 8 DTC, DTG, DTH Discovery and Other Rights: Discovery and rights to appeal in arbitration are generally more limited than in a lawsuit. This applies to both you and us. Other rights that you or we would have in court may not be available in arbitration. Please read this Arbitration Clause and consult the rules of the arbitration organizations listed below for more information. 5. SMALL CLAIMS COURT OPTION: YOU MAY CHOOSE TO LITIGATE ANY DISPUTE BETWEEN YOU AND ANY OF US IN SMALL CLAIMS COURT, RATHER THAN IN ARBITRATION, IF THE DISPUTE MEETS ALL REQUIREMENTS TO BE HEARD IN SMALL CLAIMS COURT. 6. Governing Law: For residents of the United States, the procedures and effect of the arbitration will be governed by the Federal Arbitration Act (9 U.S.C. § 1 et seq.) rather than by state law concerning arbitration. For residents of Canada, the procedures and effect of the arbitration will be governed by the applicable arbitration law of the province in which you purchased your unit. The law governing your substantive warranty rights and other claims will be the law of the state or province in which you purchased your unit. Any court having jurisdiction may enter judgment on the arbitration award. 7. Rules of the Arbitration: If the amount in controversy is less than $250,000, the arbitration will be decided by a single arbitrator. If the amount in controversy is greater than or equal to $250,000, the arbitration will be decided by a panel of three arbitrators. The arbitrator(s) will be chosen pursuant to the rules of the administering arbitration organization. United States residents may choose the American Arbitration Association (1633 Broadway, 10th Floor, New York, NY 10019, www.adr.org), JAMS (1920 Main Street, Ste. 300, Irvine, CA 92614, www.jamsadr.com), or, subject to our approval, any other arbitration organization. In addition, Canadian residents may choose the ADR Institute of Canada (234 Eglinton Ave. East, Suite 405, Toronto, Ontario, M4P 1K5, www.amic.org). These organizations' rules can be obtained by contacting the organization or visiting its website. If the chosen arbitration organization's rules conflict with this Arbitration Clause, the provisions of this Arbitration Clause control. The award of the arbitrator(s) shall be final and binding on all parties. 8. Location of the Arbitration Hearing: Unless applicable law provides otherwise, the arbitration hearing for United States residents will be conducted in the federal judicial district in which you reside or, for Canadian residents, in the province in which you reside. Part No. PWDLCPPF 7/2015 © 2014 - 2015 DAIKIN COMPANY. L.P. VAIkIru COMMERCIAL WARRANTY Models: DCC, DCG, DCH, DTC, DTG, DTH 9. Costs of the Arbitration: Each party is responsible for its own attorney, expert, and other fees unless applicable law requires otherwise. Daikin will pay your share of the fees charged by the arbitration organization and arbitrator(s) beyond the first $200. Where permissible by law, you may be required to reimburse Daikin for the fees of the arbitration organization and arbitrator(s) in whole or in part by decision of the arbitrator(s) at the discretion of the arbitrator(s). 10. Survival and Enforceability of this Arbitration Clause: This Arbitration Clause shall survive the expiration or termination, or any transfer, of the warranty on your unit. If any part of this Arbitration Clause, except waivers of class-action rights, is found to be unenforceable for any reason, the remainder of this clause and the warranty shall remain enforceable. If, in a case in which class-action allegations have been made, the waiver of class-action rights under this warranty is found to be unenforceable with respect to any part of the dispute, the parts of the dispute as to which the waiver of class-action rights have been found unenforceable will be severed and will proceed in court without reference or application of this Arbitration Clause. Any remaining parts will proceed in arbitration. OWNER NAME ADDRESS OF INSTALLATION CITY / STATE -PROVINCE / ZIP -POSTAL CODE INSTALLER. NAME CITY / STATE -PROVINCE / ZIP -POSTAL CODE PHONE # / FAX # DISTRIBUTOR NAME CITY / STATE -PROVINCE / ZIP -POSTAL CODE PHONE # / FAX # MODEL # & SERIAL # INSTALLATION DATE Part No. PWDLCPPF 7/2015 © 2014 - 2015 DA/KEN COMPANY. L.P. Page 8 8 a PCS Structural Solutions Seattle Tacoma 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 1250 Pacific Avenue, Suite 701 • Tacoma, WA 98402 • tel: 253.383.2797 STRUCTURAL CALCULATIONS www.pcs-structural.ccm FOR SEGALE PROPERTIES ROOF TOP UNIT REPLACEMENT STRANDER BLVD AND ANDOVER PARK IN TUKIAIILA INASHINGTON PREPARED BY PGS STRUCTURAL 5O1_11T/0N5 11 - FEBRUARY FEBRUARY 2S, 2017 11-304 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2017 City of Tukwila BUILDING DIVISION CITY OF TUKWILA NAR 03 2017 PERMIT CENTER t1F7o3o ra v C56Z Sid S�2( Z'•f6J <N° n' 0.+1r•1 M v� 7 " ' N019NINSV7! t3IMW1 Y 1St' NJVd if3A00NY 1V wS 2130r8.iS; 1r4ILJ 1 N30 MFu Z a-. fY •r• z W' EI e F] .I, r•ti yr ;N}F .fi't r. !qt e it• 'l :f! 1 • y' :M �� ` yy11��tt air: �.. PCS Structural Solutions Job Number = 17-304 Date = 28 -Feb -17 Name = LAH Project = Design Cilteri*:*AStE446.18tieji5 Unit Weight, Wp = 1650 Ib Includes existing curb Existing Unit Weight = 1350 Ib Roof Dead = Roof Snow = 15 psf 25 psf Segale Properties RTU Replacement - Tukwila, Washington 1.-ate'reAsialiisiit. The •new unit does not have a significant impact to the building's capacity to resist wind or seismic forces ASCE 7 Eq 13.3-1 Fp = 0.4*SDS*(1p/Rp)*a p*Wp* [1+2*Zihi = 825 Ib ASCE 7 Eq 13.3-2 Ft, max = 1.6*Sos*Ip*Wp = 2640 Ib ASCE 7 Eq 13.3-3 Fpmin = 0.3*SDs*Ip*Wp = 495 Ib SDS = 1 alrgE LLIV.b0 ASCE 7, Table 13.5-1 ap = 2.5 ASCE 7, Sec. 13.1.3 1p = 1 Icftf arsti\ ,c23,G)3 161 112 ASCE 7, Table 13.5-1 Rp = 6 height of attachment z = 18.0 ft total of height h = 18.0 ft '41(1004ti.tt,4to .2t-5).= 01316k,V; ICAZ7 Atks skoNte-r w& *\D co -u4 Awr 11,3 eAlrtkrrY1 PCS Project: u`'--' ,j��{, Subject: - — Sheet- — Name - `^' Job No:— Structural Solutions Originating Office: ❑ Seattle 2' acoma tate: • Seattle Tacoma ',75-10 tdrcto 6b Ueat ';302 U 303 L15))15 = t,b-4 (1--) a- LI- ttg, 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 www.pcs-structural.corn 1250 Pacific Avenue, Suite 701 • Tacoma, WA 98402 • tel: 253.383.2797 Project: OFFICE DEPOT System ID(s): 580DEV150220AA REPL Design Requirements Power Supply Cooling Capacity Outdoor Design Temp Indoor Dry Bulb Temp Indoor Wet Bulb Temp Total CFM ESP Configuration 480/3160 12.5 Ton 95.0 80.0 67.0 4975 0.6 Downflow Standard Features: DC Series Packaged Units - R -410A chlorine -free refrigerant - High -efficiency Copeland scroll compressor(s) - Copper tube / aluminum fin coils - High-capacity, steel -cased filter dryer - High- and Low-pressure switches - Lugged electrical contactor - Single -point power - Color Coded Wiring - Foil Faced Internal Insulation - Heavy -gauge, galvanized -steel cabinet - UV -resistant powder -paint finish - Full perimeter base rail MODEL #: Cooling Performance Total Capacity Sensible Capacity Cooling Stages Refrig Type Compressor Type Pressure Switches DCG150210413AXX Outdoor Design Temp 1 ;indoor Dry Bulb Temp Indoor Wet Bulb Temp :1 Efficiency (at ARI conditions) ;Heating Performance •Input Output AFUE 148.0 MBH 108.0 MBH Two R410A Copeland Scroll High & Low (std) 95.0 80.0 67.0 10.8 EER / 11.0 IEER 210000 Hi, 157500 Lo 168000 HI, 126000 Lo 80% Supply Air Blower Performance ; ;Total Air Supply ESP 1 Blower Type Horsepower Base Unit Electrical Data Power Supply Min Circuit Ampacity Max Overcurrent Protection Physical Attributes Be Unit' Ofier, Decibels 83 Filter(s) _ Qty (4) 20x25x2 4975 CFM 0.6 IWG Belt Drive 3 48013/60 31 Amps 40 Amps Fld hist Fct Inst Item # DDNECNJ9015013 Accessories DMenflair Eciinciffiker Plmenslons 40x20x41 Itis 135 °nr- u3Ext-k)T---- Ils---vtgAis-- 190 tkiti tteSt, Pn9e 3 0, Project: OFFICE DEPOT System ID(s): 580DEV150220AA REPL DIMENSIONS 13% ic" NPT Gas Pipe Entrance; 5319" 6 u" from bottom of rail r 12W 0 •0 L MODEL SIZE 7)4 to 10 Tons 12% Tons Horizontal Discharge DIMENSIONS 36%" 177W Vertical Discharge (Bottom of Unit) 3/1/2018 City of Tukwila Department of Community Development CHRIS TAYLOR 109 WASHINGTON BLVD - SUITE B ALGONA, WA 98001 RE: Permit No. M17-0030 OFFICE DEPOT 300 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/7/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/7/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M17-0030 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director October 5, 2017 Chris Taylor Five Star Mechanical 109 Washington Blvd — Suite B Algona, WA 98001 RE: Request for Extension #1 Permit Number M17-0030 Dear Mr. Taylor, This letter is in response to your written request for an extension to Permit M17-0030. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through April 7, 2018. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. M17-0030 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov -Is- ` tom-igOic7 3-3s- 70 0 Mo -)-s Q Extension Request: Denied (provide explanation) RECEIVED CITY OF TUKWILA OCT 042017 PERMIT CENTER 0A-< Q4 -+r J L c,„ -L ‘±-,D Alfa G--1 9,_3 6 _ sr o,ts t2 8/31/2017 City of Tukwila Department of Community Development CHRIS TAYLOR 109 WASHINGTON BLVD - SUITE B ALGONA, WA 98001 RE: Permit No. M17-0030 OFFICE DEPOT 300 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/7/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/7/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M 17-0030 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 March 15, 2017 City of `Tukwila Department of Community Development CHRIS TAYLOR 109 WASHINGTON BLVD - SUITE B ALGONA, WA 98001 RE: Correction Letter # 1 MECHANICAL Permit Application Number M17-0030 OFFICE DEPOT - 300 ANDOVER PARK W Dear CHRIS TAYLOR, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) 1. Provide quality control statement of special inspections required for the new steel framing supports. (IBC 1705) Note: This permit plan review may not be complete as revised plans may require further corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have. enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 433-7165. Sincerely,a achelle Ripley Permit Technician File No. M17-0030 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 40 Fax 206-431-3665 PERMIT COORD COPY: PLAN REVIEW/ROi1TING SLIP PERMIT NUMBER: M17-0030 DATE: 03/30/17 PROJECT NAME: OFFICE DEPOT SITE ADDRESS: 300 ANDOVER PARK W Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: ftti Al VI Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/04/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/02/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: ;Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff initials: 12/18/2013 PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0030 PROJECT NAME: OFFICE DEPOT SITE ADDRESS: 300 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # DATE: 03/03/17 Revision # L before Permit Issued Revision # after Permit Issued DEPARTMENTS: Coy W 7 Building Division IP Public Works ❑ km Piro x\10 Fire Prevention Structural Planning Division n Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 03/07/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 04/04/17 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: // 15 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW,❑ Staff Initials: T242— 12/18/2013 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard. Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the .Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M17-0030 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: OFFICE DEPOT Project Address: 300 ANDOVER PARK W Contact Person: Phone Number: Summary of Revision: 20L 61G\`‘D- No new structural members are being added or being modified. As such, no special - inspection is required of the existing members or of the work being performed from a _structural standpoint. Luke Heath, SE PCS Structural Solution RECEIVED CITY OF TUKWILA, MAR 302017 Sheet Number(s): PERMIT CENTEK "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Ni ----Entered in TRAKiT on C:\1Jscrs1Rachellc-R\I k:skI p\Ncvision Submittal Form - 1)17.113115,Jnc Revised; August 21115 FIVE STAR MECHANICAL Washington State Department of Labor & Industries Home Espanol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 2 A -Z Index help My LCI Workplace Rights Trades & Licensing FIVE STAR MECHANICAL Owner or tradesperson Principals WARE, GERALD LAVON, MEMBER WARE, JOHN EDWARD, MEMBER ALLEN, ANGELA RENEE, MEMBER WARE, BETTY J, MEMBER Doing business as FIVE STAR MECHANICAL WA UBI No. 601 937 083 109 WASHINGTON BLVD STE B ALGONA, WA 98001 253-852-8284 KING County Business type Corporation Governing persons BETTY J WARE ANGELA R ALLEN; JOHN E WARE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. - Meets current requirements. License specialties GENERAL License no. FIVESM*010JT Effective — expiration 04/30/1999— 05/01/2018 Bond Western Surety Co Bond account no. 62031473 $12,000.00 Received by L&i Effective date 05/16/2014 04/27/2014 Expiration date Until Canceled Bond history .Insurance AMCO Ins Co. Policy no. ACP3026636020 $1,000,000.00 Received by L&I Effective date 04/25/2016 04/27/2016 Expiration date 04/27/2017 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601937083&LIC=FIVESM*010JT&SAW= 4/7/2017 FIVE STAR MECHANICAL Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations - No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts Account no. 629,163-00 Doing business as FIVE STAR MECHANICAL Certificate of Workers' Comp Coverage Track this contractor Account is current. Account no. 629,163-01 Doing business as LODESTAR HVAC Certificate of Workers' Comp Coverage Track this contractor .0 Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601937083&LIC=FIVESM*010JT&SAW= 4/7/2017 NW CORNER SE1/4 NE1/4 26-23-4 METRO MANHOLES WATER UNE EASEMENT AF # 5357464 EXISTING TRAFFIC SIGNAL SET LARGE PK -NAIL & TAG LS# 17659 GAS VALVE ITRAFFIC SIGNAL. DI HANDHOLE WATER LINE EASEMENT AFf 5357464 CoLi N CNI Lit cr4-1.3 UGHT o HANDHOLES 1"••••• UGHT HANDHOLE 301 LIGHT I HANDHOLE 2 Li 10 ,-1 0 z LIGHT HANOHO 5 13 0 1.1 POWER tac „to VAULT ta co 0 30 F7z LIGHT HANDHOLE Id • 0 U) 0 tn 30' LIGHT HANOHOLE ELEC. (MANHOLE TRAFFIC SIGNAL b BOXS ELEC HANOHOLE -4arisionm SIGNAL CARNET 5' WIDE TELEPHONE EASEMENT AF# 6397207 OM, LIGHT HANDHOLE OLYMPIC P1PEUNE CO. 5' WIDE EASEMENT AF# 6683975 -SD 033 area S 8815'38" E (MEAS) S 8815'33" E (PARK NO. 3) 846.76'(MEAS) 646.83'(LEGAL) SD- 15' UTIUTY EASEMENT -AF # 7402080363 LIGHT HANDHOLES S 8815'38" E (MEAS) S -.si5 - LIGHT HANOHOLE 625.24' STRANDER (5 LANES) 10' WIDE SEWER EASEMENT AF# 5357464 625.316(LEGAL) OLYMPIC PIPELINE COMPANY 15' X 15' EASEMENT AF# 6683975 LIGHT HANDHOLES b BOULEVARD SIDEWALK AND DECELERATION LANE EASEMENT AF# 9408261548 PETROLEUM . I PIPELINE SIGN PUGET I VAULT WHEEL RAMP SET LARGE PK -NAIL & TAG LS# 17659 1083.08'(MEAS) 1080.16(PARK NO. 32 EASEMENT FOR INGRESS AND. EGRESS - -RECORDED UNDER AF# 9406240102 IR --- ....RECORDED UNDER AF f 9406240103 ADDRESS #100 POa J 2v 1o o 42.00' 10' WIDE PUGET POWER EASEMENT • API 9409160475 LEGEND - LIGHT STANDARD ▪ -CATCH BASIN X = WATER VALVE Cf - FIRE HYDRANT (1) - SANITARY SEWER MANHOLE • STORMDRAIN MANHOLE - CONCRETE COLUMN p PLANTER SD - STORM DRAIN LINE SS SANITARY SEWER UNE WAT WATER UNE ADDRESS poo WATER MtER 24 compact :paces OIL/WATER SEPERATOR 15' CITY UTIUTY EASEMENT --AF# 7402080363 planter LOT AREA 416,928 sq.ft. 9.57 acres ADDRESS #700 ADDRESS LIGHT HANDHOLE ADDRESS #400 AUTO SPRINKLER ADDRESS 1300 LIGHT HANDH 10' WIDE PUGET POWER EASEMENT AF # 9409160475 MEASURED: • A I. 8115'54. R 410.28' T - 354.13' L es 584.30' GAS METER AC -PAVEMENT CURBING ALONG PROPERTY UNE 60 1" = 30' 1111111111111111111111111111111111 siiimmtara ANDOVER INDUSTRIAL PARK NO. 5 VOL. 83 PG. 22 -t • ilia.rill= I immiaminumelimmemossimmemiamosommeimenternimmiusaminamassiniumai....rogail/0.11............"... FOUND 1/2. 1.P LS# 17659 SET 5/8" REBAR & CAP lc TAG LS# 17659 ETIARGE PK -NAIL neanswilmaramnammimmilmimiiimimitameimmilimMIlimuxiMINIMIIIIIIIIMINNI111111111111 N 84'25'50" W (MEAS) I 98.11'(LEGAL) 41=11•11 MOM GROSS LEASABLE AREAS ADDRESS SUITE #100 SUITE #200 SUITE #300 SUITE #400 • SUITE #600 SUITE #700 SUITE #800 TENANT SQ FT (INCL. IN BARNES & NOBLE SF) 25,003 SF (INCL. IN BARNES & NOBLE SF) 28,768 SF (GROUND FLOOR) 10,465 SF (MEZZANINE) BARNES & NOBLE STARBUCKS • OFFICE DEPOT 28,715 SF 18,870 SF 10,534 SF TOTAL GLA TOTAL PARKING STALLS 122,355 SF 494 STALLS PARKING RATIO (BASED ON GR. FL. ONLY) 4.42 STALLS / 1000 SF PARKING RATIO (BASED ON TOTAL GLA) 4.03 STALLS / 1000 SF MEASURED: A - 68'55'37" R 00 410.28' T 281.59' L 493.57' LEGAL A - 6855'41- R 410.28' L 493.58 OVERLAP 0.6' 0.05's x 0.23V FOUND OLD 0.11'S X 0.45'W - 10' WIDE PUGET POWER EASEMENT AF # 7601270451 23.5' WIDE RAILROAD EASEMENT AF# 7504210345 VICINITY MAP TU( P RKWAY • • InG4tier;;Zig,/:. {isiJ ctAl 158v • ;74" • C•11 /Thm • -7r i&9. yez,M.e...? • 158 ST •P 23.5' WIDE RAILROAD EASEMENT WI 75042 TRECK OR WHEEL CHAIR RMP WAT GAS VA Fire Pork RTH SET BRASS TACK k TAG LS # 17654 N 8816'17' • 406.72'(LEGAL) :v1INKLER cLVO LEGAL DESCRIPTION OF RECORD 10' WIDE PUGET POWER EASE.4ENT AFf 9409160475 THAT PORTION OF THE SOUTHEAST 1/4 OF ME NORTHEAST 1/4 OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST W.M., DESCRIBED AS FOLLOWS: BEGINNING AT THE SOUTHWEST CORNER OF 'THE SOUTHEAST 1/4 OF THE NORTHEAST 1/4 OF SAID SECTION 26; • THENCE NORTH 01'05'05. EAST ALONG THE WEST LINE OF SAID SUBDIVISION. A DISTANCE OF 609.06 FEET TO THE TRUE POINT OF BEGINNING; THENCE SOUTH 8816'17. EAST. ALONG THE NORTH LINE OF THAT CERTAIN PARCEL OF PROPERTY CONVENED TO MARRIOTT CORPORATION. A DELAWARE CORPORATION. BY DEEDS RECORDED UNDER RECORDING NOS. 8612302063 AND 8702261746, AND THE WESTERLY EXTENSION OF SAID UNE. A DISTANCE OF 406.72 FEET TO A POINT OF CURVATURE ON THE WEST UNE OF 11-1E PLAT OF ANDOVER INDUSTRIAL PARK NO. 5, AS PER PLAT RECORDED IN VOLUME 83 OF PLATS, PAGES 22 AND 23, RECORDS OF KING COUNTY: THENCE NORTHEASTERLY ALONG SAID WEST LINE OF SAID PLAT ALONG A CURVE TO THE RIGHT HAVING A RADIUS OF 410.28 FEET, THE CENTER OF' WHICH BEARS SOUTH 7832'46" EAST THROUGH A CENTRAL ANGLE OF 81'36'55AN ARC DISTANCE OF 584.42 FEET; THENCE SOUTH 8425'51* EAST A DISTANCE OF 198.11 FEET TO A POINT ON THE SOUTHWESTERLY UNE OF LOT 5 OF THE PLAT OF ANDOVER INDUSTRIAL PARK NO, 3, AS PER PLAT RECORDED IN VOLUME 78 OF PLATS, PAGES 6 AND 7, RECORDS OF KING COUNTY: • THENCE NORTHWESTERLY, ALONG THE SAID SOUTHWESTERLY UNE OF SAID LOT 5 ALONG A CURVE TO THE RIGHT HAVING A RADIUS OF 410.28 THE CENTER OF WHICH BEARS NORTH 06'24'49* EAST THROUGH A CENTRAL ANGLE Cf' 68'55'41" AN ARC DISTANCE OF 493.58 FEET; THENCE NORTH 14'39'30 WEST A DISTANCE OF 120.44 FEET TO THE NORTH UNE OF 'THE SOUTHEAST 1/4 OF THE NORTHEAST 1/4 OF SAID SECTION 26; ' THENCE NORTH 8815'33" WEST ALONG SAID NORTH LINE A DISTANCE OF 646.83 FEET TO THE NORTHWEST CORNER OF SAID SUBDIVISION; THENCE SOUTH 01'05'05" WEST ALONG THE WEST LINE OF SAID SUBDIVISION A DISTANCE OF 718.10 FEET TO THE TRUE POINT OF BEGINNING; EXCEPT THE NORTH 30 FEET THEREOF FOR STRANDER BOULEVARD; AND EXCEPT THE WEST 30 FEET THEREOF FOR ANDOVER PARK WEST: • SITUATE IN THE CITY OF TUKWILA. COUNTY OF KING, STATE OF WASHINGTON. SET LARGE PK -NAIL & TAG LS# 17659 IN RR TIE FOUND LARGE PK -NAIL & TAG LS # 22338 0.11'N X 0.20V SW CORNER 5E1/4 NE1/4 26-23-4 32 • y ------ .11 T WaryWillimonamoOMP04.11.4011M.WwIJOIllaNW001.11.0.ADV.W SEARAT7 REQUI17-17D 0 Ncnnc2! fierEfectricz.il erPlumbing Pip!no City of T2 PLAT MON • Permit R17.LEivtcl---7Yom Plan MieW [1pre..! 13 subject to errors and omission. Approval of constrZjon C:JCImerits does no Z authorize the violation of any adopted c• e or ordinance. Recelpt of approved Field opy and odr4ris is acknowledged: By: • Date: City of Tukwila • BUILDING DIVISION MI7 • No chances shall be made to the scope of work without prior approval of T. I •-• •-• • RECEIVED CITY OF TUKWILA MAR Oa 2017 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2017 tc.1 41=24021141011111111211M1e" TUKWILA, WASHINGTON DESIGNED CHECKED E RW8 DRAWN BY R80 DATE 8/94 PROJ. NO. • 1093-4 SEC. TWP. RNG.• 28 23 4 • SCALE • 30* SHEET 1 OF 1 requiro Wan submittal ar n:.1`.7 Cael