Loading...
HomeMy WebLinkAboutPermit M17-0039 - COSTCO / OPTICAL - GAS RADIANT HEATERCOSTCO OPTICAL 400 COSTCO DR M17-0039 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov 3523049089 400 COSTCO DR COSTCO - OPTICAL MECHANICAL PERMIT Permit Number: M17-0039 Issue Date: 4/24/2017 Permit Expires On: 10/21/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: COSTCO WHOLESALE CORPORATIO 999 LAKE DR PROPERTY TAX DEPT 006, ISSAQUAH, WA, 98027 KAYLENE NELSON 1221 SECOND AVE N , KENT, WA, 98032 HERMANSON COMPANY LLP 1221 2ND AVE N , KENT, WA, 98032- 2945 H E RMACL005 BJ 111 Phone: (253) 359-7147 Phone: (206) 575-9700 Expiration Date: 8/25/2018 DESCRIPTION OF WORK: INSTALL ONE GAS RADIANT HEATER Valuation of Work: $9,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $326.96 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: KbU- 4,//ty_ la vn 1,6,47-C Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 8: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2013 edition). 6: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 7: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 10: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW_ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. 1 Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 400 Costco Drive Tukwila, WA 98188 King Co Assessor's Tax No.: 2523049063 Suite Number: Floor: 1 Tenant Name: Costco Wholesale / otifICAV PROPERTY OWNER Name: Kaylene Nelson Address: 1221 2nd Avenue N Name: Costco Wholesale Phone: (253) 359-7147 Fax: Email: Kaylene.nelson@hermanson.com Address: 999 Lake Drive Cin': Issaquah State: WA zip: 98027 CONTACT PERSON — person receiving all project communication Name: Kaylene Nelson Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Email: Kaylene.nelson@hermanson.com New Tenant: ❑ Yes ❑ .. No MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Contr Reg No.: HERMACL005BJ Exp Date: 08/25/2018 Tukwila Business License No.: BUS -0994464 Valuation of project (contractor's bid price): $ 9,000 Describe the scope of work in detail: Provide and install one Gas Radiant Heater. Use: Residential: New ❑ Replacement ❑ Commercial: New ® Replacement ❑ Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 3-9-1 Ldocx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater 1 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/1 00,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: Print Name: Kaylene Nelson AU HORI . ED ENT: Mailing Address: 1221 2nd Avenue N H:\Applications\Forms-Applications On Line\201 I Applications\Mcchanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Date: 03/20/2017 Day Telephone: (253) 359-7147 Kent WA 98032 City State Zip Page 2 of 2 1 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK 'QUANTITY PAID $143.38 M17-0039 Address: 400 COSTCO DR Apn: 3523049089 $62.88 Credit Card Fee $1.83 Credit Card Fee 1 R000.369.908.00.00 0.00 $1.83 MECHANICAL $61.05 PLAN CHECK FEE 1 R000.322.102.00.00 0.00 $61.05 PG17-0034 Address: 400 COSTCO DR Apn: 3523049089 $25.61 Credit Card Fee $0.75 Credit Card Fee R000.369.908.00.00 I 0.00 $0.75 GAS $24.86 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.86 PG17-0035 Address: 2811 S 102ND ST 220 Apn: 0423049190 $54.89 Credit Card Fee $1.60 Credit Card Fee I R000.369.908.00.00 0.00 $1.60 GAS $24.86 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.86 PLUMBING $28.43 PLAN CHECK FEE R000.322.103.00.00 0.00 $28.43 Date Paid: Monday, March 20, 2017 Paid By: KAYLENE NELSON Pay Method: CREDIT CARD 169371 Printed: Monday, March 20, 2017 12:58 PM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $264.08 M17-0039 Address: 400 COSTCO DR Apn: 3523049089 $264.08 Credit Card Fee$7.69 Credit Card Fee R000.369.908.00.00 0.00 $7.69 MECHANICAL $244.18 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $211.03 TECHNOLOGY FEE $12.21 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11339 R000.322.900.04.00 0.00 $12.21 $264.08 Date Paid: Monday, April 24, 2017 Paid By: HERMANSON COMPANY Pay Method: CREDIT CARD 780869 Printed: Monday, April 24, 2017 2:20 PM 1 of 1 RSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 14417 -( '3 Project: (tel/rij 611104-L_ Type of Inspection: illiz/)4 i1C4 // -L. Ad ress: 4 er CO --7-0 be Date Called: Special Instructions: Date Wanted %` m. �a Requester. ..t5,', IV Phone No: 2 /7—/ 2 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ¢OtZ Project: y� Type of Inspection: 1 Address: Date Called: Special Instructions: Date Wanted 5425---i 7 _ i:rn p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: //%%uCs- Inspector: 85 - REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION. RECORD Retain a copy with per'mit1 rvi (26;7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: CO51-r6 604--(cc.4 Type of Inspection: rig- //,.1/4-- Address: j r Suite #: d 6 Co ` v Contact Person:I ,%� t k. --e.- 1t�l / le.vMatv4. 5 Special Instructions: Permits: Phone No.: F -1,-y2.- 6--ivo-i-6, K v9 -7,v' - Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: v & ) Fire Alarm: kt E Hood & Duct: -es- Monitor: :/ ✓ice -6N if i . / f ri-6 v c1) -,e7/ h4`) s Permits: F -1,-y2.- 6--ivo-i-6, K v9 -7,v' - Py Needs Shift Inspection: 4 t 5 Sprinklers: v & ) Fire Alarm: kt E Hood & Duct: -es- Monitor: Pre -Fire: /V ePiSE"-) Permits: Occupancy Type: 11/1 Inspector: j Date: 5-7;----/13__ Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department.. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 ?EAPv11T CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0039 PROJECT NAME: COSTCO - OPTICAL DATE: 03/20/17 SITE ADDRESS: 400 COSTCO DRIVE X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: G Building Division Public Works El 11 kM MVO 11Z Fire Prevention Structural Ta Planning Division Permit Coordinator n El PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 03/21/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 04/18/17 Approved with Conditions ❑ Corrections Required Denied (corrections entered 'n Reviews) (ie: Zoning Issues) Notation: `"O DV I0. ( v REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 HERMANSON COMPANY LLP Home Espanol Contact Safety & Health Claims & Insurance 4114 Washington State Department of Labor & Industries Search L&I Page 1 of 3 A -Z Index 1-lelp My I&I Workplace Rights Trades & Licensing HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNOT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No. 602 004 844 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County Business type Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HERMACLOO5BJ Effective — expiration 01/11/2000— 08/25/2018 Bond WESTERN SURETY CO Bond account no. 929381801 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 4/7/2017 HERMANSON COMPANY LLP Insurance Valley Forge Ins Co $1,000,000.00 Policy no. 6043050846 Received by L&I Effective date 08/15/2016 08/21/2016 Expiration date 08/21/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 409,648-01 Doing business as • HERMANSON COMPANY LLP Estimated workers reported Quarter 4 of Year 2016 "Greater than 100 Workers" L&I account representative T1 / NIKKI BUTLER (360)902-4918 - Email: BUTQ235@Ini.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 02/23/2016 Inspection no. 317939295 Location 15580 NE 31st St. Redmond, WA 98052 No violations Inspection results date 05/21/2015 Inspection no. 317935231 Location 4480 154th PI NE Redmond, WA 98052 No violations Inspection results date 12/10/2014 Inspection no. 317424935 Location 21601 76th Ave W. Edmonds, WA 98026 No violations Inspection results date 05/17/2013 Violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004$44&LIC=HERMACL005BJ&SAW= 4/7/2017 CONNECT NEW 1/2" GAS W/PRV TO EXISTING GAS ON ROOF. C L -r- REMOVE EXISTING UNIT & INSTALL NEW UNIT PER SCHEDULE. SEE DETAIL C?) PARTIAL FLOOR PLAN SCALE: 1/16" = 1'-0" 8/8 CD -4 100 CFU (E) VD (E-)8"0 24/12 RG • THERMOSTAT (E)8.,o RELOCATE BRANCH DUCT AS SHOWN. PROVIDE NEW DIFFUSER. (E 8/ F -CD -- 1017 CFM 24/12 RG 6'0, 0/10 150 VD 'D-4 FM 18 X 8 X :E)8"0 to qY 10" VD 8/8 CD -4 100 CPU 10 10 CD -4 50 CFM FIELD VERIFY SIZE AND REUSE EXISTING LOCATION OF SUPPLY OPENING IN AND RETURN DUCTING. SUPPLY DUCT G EXISTING WATER HEATER UNDER SINK TO REMAIN G G (E)3" GAS 1O"0 10/10 CID -4 250 FM ID 1 PIPING SYSTEMS THE FOLLOWING NOTES APPLY TO AU. PLUMBING PLANS. 1. APPLICABLE PLUMBING CODE: 291:2r UPC 2415'- 2. O15'2. ALL WASTE PIPING, CONDENSATE PIPING & STORM DRAIN PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. 3. SURFACE MOUNTED PIPING WILL NOT BE ACCEPTABLE IN FINISHED ROOMS OR COOLERS. PIPING AND CONDUIT OF ALL TYPES SHALL BE CONCEALED WITHIN WALLS, FLOORS, CEILINGS (INCLUDING CONDENSATE DRAIN LINES, WATER HEATER PRESSURE RELIEF LINES AND SODA LINES). 4. INSULATE ALL INTERIOR PIPING; STORM DRAIN, HOT, COLD, RECIRC, AND CONDENSATE PER SPECIFICATION SECTION 22 07 00. 5. PIPING IN ROOF TRUSS SPACE TO BE RUN PERPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS, FOR PASSING BELOW SOUD GIRDERS MOUNT PIPING 6" MAXIMUM FROM BOTTOM OF GIRDER. DO NOT BLOCK LIGHTING & SKYLIGHTS. GENERAL MECHANICAL NOTES THE FOLLOWING NOTES APPLY TO ENTIRE PLAN AS APPLICABLE. 1. M.C. SHALL ENSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON PLAN ON THE INSIDE & OUT OF THE BUILDING. THIS INCLUDES HVAC UNITS & EXHAUST FANS. LABELS SHOULD BE IN 6" BLOCK LETTERING IN BLACK COLOR AND LOCATED WHERE EASILY VISIBLE FROM THE ROOF HATCH. 2. MAINTAIN A MINIMUM OF 10'-0" BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. 3. COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OR PANELS. 4. DIMENSIONS ARE TO COLUMN LINES. 5. APPLICABLE BUILDING CODE 2015 IBC APPLICABLE MECHANICAL CODE: 2015 IMC APPLICABLE ENERGY CODE: 2015 WASHINGTON STATE ENERGY CODE 6. PROVIDE TIE DOWN FOR ALL FLUES & VENTS OF 3' OR TALLER. 7. FIELD VERIFY EXISTING FIRE SPRINKLERS AND DUCT DETECTORS. REINSTALL AND RECONNECT DUCT DETECTORS OR REPLACE WITH EQUAL. 8. ALL CONDENSATE PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. 9. RUN PIPING IN ROOF TRUSS SPACE PERPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS, FOR PASSING BELOW SOUD GIRDERS MOUNT PIPING 6" MAXIMUM FROM BOTTOM OF GIRDER. DO NOT BLOCK LIGHTING & SKYLIGHTS. DEMO EXISTING SUPPLY DUCT PROVIDE NEW 10" SUPPLY DUCT. OPTICAL CENTER HVAC PLAN SCALE: 1/4" = 1'—O" CONNECT 1/2" H&CW TO THE NEW SINK. OES 3/4" G (E)3/4" CW 0 NEW 10" DUCT FROM EXISTING AS SEE FIT FOR NEW SUPPLY DIFFUSER. MAINTAIN DUCT SIZE. PROVIDE 1/2" H & CW SEE DETAIL CONNECT NEW 3/4" CW TO EXISTING 3/4" APPROX. HERE. FIELD VERIFY SIZE AND LOCATION. SEE DETAIL RADIANT HEA LOCATE BETWEEN EXISTING LIGHTS. MINIMUM 12' 6" AFF. C HVAC LEGEND k 24/48 k t Le, TV N -C- 0 CONT. TYP. CFM DB DG WB MBH ESP RG CD RA SA CO VD MBS M.0 G.0 AIR DUCT - FIRST # IS SIDE SHOWN FLEXIBLE DUCT CONNECTION TURNING VANE SUPPLY DUCT UP RETURN DUCT UP SUPPLY DUCT DOWN RETURN DUCT DOWN AIR VOLUME DAMPER CEILING DIFFUSER SQUARE TO ROUND DUCT TRANSITION CONDENSATE DRAIN AIR CONDITIONER #1 THERMOSTAT CONTINUATION TYPICAL CUBIC FEET PER MINUTE DRY BULB TEMPERATURE DOOR GRILLE WET BULB TEMPERATURE 1,000 BRITISH THERMAL UNITS/HR. EXTERNAL STATIC PRESSURE RETURN GRILLE CEILING DIFFUSER RETURN AIR SUPPLY AIR CLEAN OUT VOLUME DAMPER METAL BUILDING SUPPLIER MECHANICAL CONTRACTOR GENERAL CONTRACTOR MECHANICAL PLAN NOTES SEE BUBBLE ON PLAN FOR SPECIFIC REFERENCE. (E)3/4" CW G ---G— — G OPTICAL CENTER PLUMBING PLAN SCALE: 1/4" = 1'-0" (E)1/2" d3 LJ O2 NEW AC UNIT ON ADAPTOR CURB. REPLACE EXISTING AC UNIT WITH NEW AC UNIT. INSTALL ADAPTOR ON EXISTING CURB AND NEW AC UNIT ON ADAPTOR. CONNECT GAS AND CONDENSATE WHERE APPLICABLE. FIELD VERIFY SIZE, LOCATION AND DIMENSIONS OF EXISTING AC UNIT AND CURB. SCRAPE EXISTING GASKET AND ADHESIVE FROM CURB AND REPLACE WITH NEW NEOPRENE GASKET FOR BOTH ADAPTER CURB AND NEW UNIT. ADAPTOR CURB TO BE PRE-ENGINEERED BY THYBAR OR EQUIVALENT. FOR COORDINATION WITH THYBAR CONTACT BILL MARZEC (775-343-0600) ® THYBAR TO ORDER ADAPTOR CURBS. EXISTING STAINLESS STEEL CURBS TO BE EQUIPPED WITH STAINLESS STEEL ADAPTOR CURBS. G.C. TO SUBMIT STAMPED DRAWING FOR ADAPTOR CURB. SUBMITTAL TO INCLUDE CONNECTIONS BETWEEN EXISTING CURB & ADAPTOR CURB; AND CONNECTION BETWEEN ADAPTOR CURB & NEW AC UNIT; AND ADAPTOR CURB WEIGHT. (E)3/4" l RFI 04 01/13/17 f////f////////11/7/7 E J DEMO (E) RADIANT HEAT IN OPTICAL. CAP 1/2" LINE. FIELD VERIFY SIZE & LOCATION. (E)4" NEW 1 1/2" VENT. CONNECT TO EXISTING VENT APPROX HERE. FIELD VERIFY LOCATION. L / (E)6" (E)2" O CONNECT NEW 1/2" GAS W/PRV TO EXISTING 3/4" APPROX HERE IN TRUSS SPACE. FIELD VERIFY SIZE & LOCATION. (E)2" PLUMBING LEGEND A C V G III A.F.F. A.H.J. B.F.F. CO CONT. CW FCO G.0 G.V H&CW HW I N. WC M.0 PSI SCO S.S. TYP. U VTR W. WCO WASTE/SANITARY SEWER VENT COLD WATER HOT WATER HOT WATER CIRCULATION AIR CONDENSATE DRAIN GAS GAS COCK UNION VALVE - GATE VALVE - PRESSURE REDUCING (PRV) CAP OFF ABOVE FINISH FLOOR AUTHORITY HAVING JURISDICTION BELOW FINISH FLOOR CLEAN OUT CONTINUATION COLD WATER FLOOR CLEAN OUT GENERAL CONTRACTOR GATE VALVE HOT & COLD WATER HOT WATER INCHES OF WATER COLUMN MECHANICAL CONTRACTOR POUNDS PER SQUARE INCH SURFACE CLEAN OUT SANITARY SEWER TYPICAL UNION VENT THRU ROOF WASTE WALL CLEAN OUT GAS SIZE CHART PRESSURE IN WC 7 PRESSURE DROP 0.5 MAX DEVELOPED LENGTH (FEET) 100 PIPE SIZE ( UPC) MAX LOAD (MBH) MAX LOAD (MBH) 1/2" 3/4" 47 3/4" 556 98 1" 1-1/2" 185 1-1/4" 3,291 380 1-1/2" 3" 570 2" 18,914 1,098 2-1/2" 8" 1,750 3" REGULATORS AT EACH PIECE OF 3,093 4" #496 6,309 6" SPRING - GREEN 18,483 8" 325-5L600 37,976 CONNECT NEW 2" WASTE LINE TO EXISTING LINE LOCATED ABOVE FLOOR AND BEHIND WALL APPROX. HERE. FIELD VERIFY SIZE, LOCATION, AND I.E. PRIOR TO WORK 1-1/2" RFI 04 01/13/17 GAS SIZE CHART PRESSURE PSI 2 PRESSURE DROP PSI TO 1.0 MAX DEVELOPED LENGTH (FEET) 800 PIPE SIZE( UPC) MAX LOAD (MBH) 1/2" 141 3/4" 295 1" 556 1-1/4" 1,141 1-1/2" 1,709 2" 3,291 2-1/2" 5,245 3" 9.273 4" 18,914 6" 55,407 8" 113,841 PROVIDE ONE OF FOLLOWING REGULATORS AT EACH PIECE OF EQUIPMENT SENSUS MODEL #496 PIPE SIZE - 3/4" OR 1" ORIFICE - 3/8" SPRING - GREEN FOR GAS LOAD UP TO 760 MBH MAXITROL MODEL: 325-5L600 PIPE SIZE - 3/4" OR 1" FOR GAS LOAD UP TO 340 MBH 325-7AL21 OD PIPE SIZE 1-1/4" OR 1-1/2" FOR GAS LOAD BETWEEN 340 MBH AND 1000 MBH *ALL GAS PRESSURE REGULATORS TO BE RATED FOR 5 PSI. No chanoso of Twort( �1rifhc. i Ukt'' ra EI I:I^i -NOTE: Fevison3.w U -i Ali and may inLlude addiAio r"'de to the scope Coproval of ro ar. V-Pansubmittai al plan revra'rr fess FILE COP Permit Vidor ti Plan rl v. : ° i3 ;Jed to of CO3 a_ J0fl 6 a r'roei the violation of any adopte ° code of approved Field Copy and c'*nd C C By: Date: 49/2/ •;, ^lT FOR: cilartcai ncal l Plumbing C2.2s Piping. I l C.,,, , ci T ukwiia El'`'.`'`r'''. DIVI;.:^!OlN OPTICAL CENTER WASTE & VENT FL SCALE: A City of T , UILDINC S1O ECEIVED OF CITDI TUII{WILA AR 202017 owl 0, C r5 and Oil -n:31023. r°0C I1 s au:.;i1r,Tfi7.3 # r rdin€tnce. F1 yF l i IOiL IS acknc.v'odif,pd: 1-1 or PERMIT CENTER 0 4.4 CHECKED: ANT/PKR DRAWN: TB ISSUE DATE: JULY 2016 ARCHITECT REFERENCE NO: 93-0440-30 -J 0 3z Z I - ow w0 O {- U Z 00 oU v1 Z � W r me 0 Z CI. w gW E- U 01 o� 0 I- F- 0ce D_ zo O a 0 01 Co M 0 C 0 0 CO 0 0 0 U) N 0 U) I_ Li W a Co 0 0 0 0 0 U z 0 c.) 0 0 0 U) U) N W 10 cp 4.1 A O CD C 0.3�p (s7p�Cc\2� y p r a EQ zwoz Z �.14 co MX CO CO .—I CO REVIEWED FOR ODE COMPLIANCE APPROVED APR 0 4 2017 By Ferguson Construction, In Qui 04 01/13/17 4" TYPE "B" VENT CAP- = = = = 4" TYPE "B" VENT PIPE-\ NON -HARDENING CAULK ROOF -� DECK TITE OBTAINED FROM MBS CEILING CLOSURE PLATE 4" SINGLE-� WALL PIPE VENT ADAPTER n {n 24" MIN. T -STAT OR TIMER (Do AUTOMATION DIRECT ECX2300-10K POTENTIOMETER IN PBGX1 WALL MOUNT NEXT TO T -STAT TIMER. I 0 0 0 J10 JUMPER POSITION SHOWS "CENTRAL" DESIGNATION AND "POTENTIOMETER" CONTROL METHOD. 0 0 J 1 � DO A B 0 0 0 0 0 J10 I0 0 01 SINGLE VENT WIRING CANOPY/TIRE INSTALL INFRARED HEATER DETAIL SCALE: NONE NOTE: VERIFY MINIMUM CLEARANCE TO COMBUSTIBLES. UNISTRUT-\ TUBE/REFLECTOR HANGER BURNER TUBE REFLECTOR INFRARED HEAT EQUIPMENT SCHEDULE - S.I.C. SYMBOL ITEM SERVES MFR/# DESCRIPTION ELECT. WEIGHT REFERENCE REMARKS NOTES RH-1 INFRARED HEATER OPTICAL RG VANTAGE CTH3-80 INFRARED TUBE HEATER, 52-80 MBH INPUT, 20' LENGTH ALUMINIZED TUBE W/ALUMINUM 45' TILT REFLECTOR. CONTROLLED BY T'STAT TIMER SWITCH. MOUNT EMITTER TUBE AT 17' A.F.F. 120V/10 1.3 FLA 126# PLAN M-1.1 28/M T'STAT W/LOCKING COVER AND MODULATING TIMER SWITCH INSTALLED BY M.C. MOUNT AT 12'6" MINIMUM AFF. GENERAL NOTES: - EQUIPMENT TO BE PROVIDED AND INSTALLED BY M.C. - M.C. TO PROVIDE CONTROL WIRE AND CONDUIT FOR T'STAT - T'STAT TO BE MOUNTED 0 78"A.F.F. UNLESS NOTED OTHERWISE COSTCO WHOLESALE T.E., Inc. 830 NORTH RIVERSIDE DRIVE RENTON, WASHINGTON 98057 PHONE: 425-970-3753/FAX: 425-970-3756 TUKWILA, WA 98188 ONO PART OF THIS DOCUMENT MAY BE USED OR COPIED IN WHOLE OR IN PART WITHOUT THE PRIOR WRITTEN CONSENT OF T.E.INC. JOB #: 15-302 SKM2 A M17 0039 CEIVCD CITY OF TUKWILA MAR 2 0 2017 PERMIT CENTER ARCH #: 93-0440-30 DRAWN BY: tb DATE: 1/13/2017 SCALE: NOT TO SCALE CHECK BY: ANT/PKR REVIEWED FOR CODE COMPLIANCE APPRVED APR 0 4 2017 • City of Tukwila BUILDING DIVISION!