Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M17-0057 - TUKWILA SCHOOL DISTRICT - TRANSPORTATION BUILDING
TSD TRANSPORTATION BLDG 3825 S 128 ST MI 7-0057 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT 2384200010 Permit Number: 3825 S 128TH ST Issue Date: Permit Expires On: Project Name: TSD - TRANSPORTATION BLDG M 17-0057 8/14/2017 2/10/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA SCHOOL DISTR #406 4640 S 144TH ST, TUKWILA, WA, 98168 ALEXANDER CLARK AIA 105 SOUTH MAIN ST #323 , SEATTLE, WA, 98116 Phone: (206) 624-4222 HOLMBERG COMPANY Phone: (425) 822-2233 15400 SE 30TH PL, STE 100 , BELLEVUE, WA, 98007 HOLMBC*066ME Expiration Date: 9/1/2017 DESCRIPTION OF WORK: PROVIDE NEW HVAC SYSTEM, 2 ZONES, SERVING OFFICES, BREAKOUT SPACES, REST ROOMS AND TRAINING AREA. SYSTEM SHALL BE SPLIT HEAT PUMPS CONTROLLED VIA THERMOSTATS AND NEW ENERGY MGMT SYSTEM. PROVIDE EXHAUST FANS, TOTAL OF 4. PROVIDE RANGE HOOD, TYPICAL OF 1. PROVIDE ALL CORRESPONDING DUCTWORK, DIFFUSERS AND ROOF CAPS Valuation of Work: $185,914.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $2,405.84 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: �� Date: cZA Print Name: G/;G7b ILIP'ti-� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW. 1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. M IM -OQ1 Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 12801 E. Marginal Way S., Tukwila,WA 98168 Suite Number: Floor: Tenant Name: Tukwila School District.- 171prZ OIJ New Tenant: ❑ Yes j..No PROPERTY OWNER Name: A emZ Name: Tukwila School District City: s.64.77,- State:,, Zip: 4w Address: 4640 South 144th St. Email: City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: A emZ Address: /4$ 5. /0 S7 5wie. s2,3 City: s.64.77,- State:,, Zip: 4w Phone: Fax: Email: MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Provide new HVAC system, 2 zones, serving offices, breakout spaces, rest rooms and training area. System shall be split heat pumps controlled via thermostats and new energy management system. Provide exhaust fans, total of 4. Provide Range hood, typical of 1. Provide all corresponding ductwork, diffusers and roof caps. X 85; 9/Y Use: Residential: New ❑ Replacement ❑ Commercial: New 2 Replacement ❑ Fuel Type: Electric Gas El Other: H:Wpplications\Forms-Applications On Line \2016 Applications\Mcchanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 4 Furnace >100k btu 22 Floor furnace 2 Suspended/wall/floor mounted heater 2 Appliance vent 1 Repair or addition to heat/refrig/cooling system 2 Air handling unit 65 dB(A) <10,000 cfm 2 Unit Type Qty Air handling unit 4 >10,000 cfm 22 Evaporator cooler 2 Ventilation fan connected to single duct 57 dB(A) Ventilation system 2 Hood and duct 1 Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper 4 Diffuser 22 Thermostat 2 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE AWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Signature: Print Name: Mailing Address: 0 S W41n) X32.5 H:Wpplications\Forms-Applications On Line \2016 Applications\Mechanical Pcrmit Application Rcviscd 1-4-16.docx Rcviscd: January 2016 bh Date: /S/1<1 Day Telephone: 7P, 9-12 22-- 0)4- City 2--0) -City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PAID PermitTRAK $5,767.50 M17-0056 Address: 13601 32ND AVE S Apn: 1623049038 $3,557.17 MECHANICAL $3,387.78 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $3,354.63 TECHNOLOGY FEE $169.39 TECHNOLOGY FEE 1 R000.322.900.04.00 0.00 $169.39 M17-0057 Address: 3825 S 128TH ST Apn: 2384200010 $1,943.18 MECHANICAL $1,850.65 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $1,817.50 TECHNOLOGY FEE $92.53 TECHNOLOGY FEE ( R000.322.900.04.00 0.00 $92.53 M17-0058 Address: 4242 S 144TH ST BLDG 1 Apn: 1523049108 $267.15 MECHANICAL $254.43 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $221.28 TECHNOLOGY FEE $12.72 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R12125 $12.72 $5,767.50 Date Paid: Monday, August 14, 2017 Paid By: HOLMBERG COMPANY Pay Method: CHECK 65743 Printed: Monday, August 14, 2017 12:02 PM 1 of 1 IRPSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK PAID $3,438.09 D17-0110 Address: 4242 S 144TH ST BLDG 1 Apn: 1523049108 $569.36 DEVELOPMENT $569.36 PERMIT FEE R000.322.100.00.00 0.00 $69.83 PLAN CHECK FEE R000.345.830.00.00 0.00 $499.53 EL17-0308 Address: 13601 32ND AVE S Apn: 1623049038 $868.20 ELECTRICAL $868.20 PLAN CHECK FEE R000.345.832.00.00 0.00 $868.20 EL17-0309 Address: 12801, E MARGINAL WAY S Apn: 2384200010 $407.60 ELECTRICAL $407.60 PLAN CHECK FEE R000.345.832.00.00 0.00 $407.60 EL17-0310 Address: 4242 S 144TH ST BLDG 1 Apn: 1523049108 $109.92 ELECTRICAL $109.92 PLAN CHECK FEE 1 R000.345.832.00.00 0.00 .. $109.92 M17-0056 Address: 13601 32ND AVE S Apn: 1623049038 $846.95 MECHANICAL $846.95 PLAN CHECK FEE R000.322.102.00.00 0.00 I $846.95 M17-0057 Address: 12801 E MARGINAL WAY S Apn: 2384200010 $462.66 MECHANICAL $462.66 PLAN CHECK FEE 1 R000.322.102.00.00 I 0.00 I $462.66 M17-0058 Address: 4242 S 144TH ST BLDG 1 Apn: 1523049108 $63.61 MECHANICAL $63.61 PLAN CHECK FEE R000.322.102.00.00 0.00 I $63.61 PG17-0048 Address: 12801 E MARGINAL WAY S Apn: 2384200010 $109.79 PLUMBING $109.79 PLAN CHECK FEE R000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R11350 0.00 $109.79 . $3,438.09 Date Paid: Tuesday, April 25, 2017 Paid By: TUKWILA SCHOOL DISTRICT Pay Method: CHECK 95046 Printed: Tuesday, April 25, 2017 12:59 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: TV W(01-4 ,a7125int- Type of Inspection: Address: 3Orep/ 2 Pi / .5! / �yy 4 5n Date Called: Special Instructions: M Kei44Aii aft- Ili" r Date Wanted: .18 a.m� Requester: , Phone No: pproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: c'k ri CC ich-L OWN,` Inspector: s Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 MI7 CX 57 Project: 1?1<vOrr--A-- 4— pis /— Type of Inspection: Address: Address: Date Called: Special Instructions: TRANS', , B Cr,p.m. Date Wanted: a.m.,, Requester:er� R00 Ttty / 1 Phone No:7-e AQfe Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: 3 Date: z _2_7 zZ _464) REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 lAN17-Cx57 (206) 431-3670 Project: 11A41.01.41- srileor_ pis' 1 Type of Inspection: palJ6.14_ -r$ W1,C 4AMK "[-- Address: 3825' 'i 128114 37 Date Called: Special Instructions: TRANS , a-1)6- Date Wanted: (-2.5`43 a.m: p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Rai'16 fN /*V ci-44Wic4-L . Inspector: Date: / _2 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Tukwila School District Transportation Building Page 1 Memorandum To: Project: Re: Date: June 5, 2017 Bill Rambo From Alexander Clark, AIA Permit Technician Principal City of Tukwila Rolluda Architects, Inc Tukwila School District Transportation Building Project #: 331-16-01 Applicant Response to Mechanical Permit Application # M17-0057 Correction Letter #1 Dear Mr. Rambo, The following are our responses to your Correction Letter#1 dated May 2, 2017. RAI Reply The office type lunch room residential appliances will only be used for Boiling, steaming and warming pre-cooked foods. The cooking hood provided vents to the outside. Per the IMC Washington State Amendments Table 507.1.2, a residential hood is allowed in an office lunch room, where boiling steaming or pre-cooked food is being prepared.; Solution: A prominent plastic plaque, 12"x6" with 1" letters, will be placed on the back wall adjacent to the electric range stating that "No roasting, pan frying or deep frying is allowed in or on appliances. Per IMC Washington State Amendments Table 507.1.2" Drawing adjustments: See revised sheets A2.01 and A8.01 for revised ilanguage and location of plaque. We believe this satisfies the code requirements per our phone conversation. Please let us know if you have any questions or further comments. Thank you, CORRECTION Alexander Clark, AIA LTR# Principal Rolluda Architects, Inc. Encl. Sheet A2.01 and A801 revised RECEIVED CITU OF TUKWILA JUN 06 2011 PERMIT CENTER t4ii• 0057 May 10, 2017 City of Tukwila Department of Community Development ALEXANDER CLARK AIA 105 SOUTH MAIN ST #323 SEATTLE, WA 98116 RE: Correction Letter # 1 MECHANICAL Permit Application Number M17-0057 TSD - TRANSPORTATION BLDG - 12801 E MARGINAL WAY S Dear ALEXANDER CLARK AIA, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: FIRE - M DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. • The scope of work for this permit mentions the installation of a Type 1 kitchen hood and there is a reference to a kitchen hood with fire protection system on sheet #TM4.01. However, there are no details for the Type 1 hood provided. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. M17-0057 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0057 DATE:. 06)06/17 PROJECT NAME: TSD - TRANSPORTATION BLDG SITE ADDRESS: , _ .: 30)1 5 id -0 S÷. Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division Public Works E A-iA M te`r7`H7 Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 06/08/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 07/06/17 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0057 DATE: 04/28/17 PROJECT NAME: TSD - TRANSPORTATION BLDG SITE ADDRESS: 12801 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 144,E-- *tic,'-�-� Building Division Public Works El Covi Fire Prevention 1 Planning Division ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/02/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required (corrections entered in Reviews) Notation: DUE DATE: Approved with Conditions Denied ❑ (ie: Zoning Issues) 05/30/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED:"��� Departments issued corrections: Bldg 0 Fire' - Ping 0 PW 0 Staff Initials: tut 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must he submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /oq.21-7-- Plan Check/Permit Number: M17-0057 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: TSD — Transportation Bldg Project Address: 12801 E Marginal Way S ,4 (tze z - avvd e--- Phone : 2O ip (a7-54 42/zz_ Contact Person: RECEIVED CITY OF TUKWILA JUN 0 6 2011 PERMIT CENTER Summary of Revision: 5"- _ kCt`g WI4mo gfeti, 19 RoLLu s IN fi4 L LO LJ 044;- ;49J e.t> Sheet Number(s): %� • 01 f 1-b, "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: E —Entered in TRAKiT on "'' (p ( 7 \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: HOLMBERG COMPANY I-leme Espanol Contact Safety & Health Claims & Insurance Washington State Department of iLAIP Labor & industries Search L&I Page 1 of 3 A-7 Index help My L&I Workplace Rights Trades & Licensing HOLMBERG COMPANY Owner or tradesperson Principals WHITE, JEFF K, PRESIDENT BAILOR, WADE WAYNE, VICE PRESIDENT TOBIN, MARK ALLEN, SECRETARY HOLMBERG, A PHER, VICE PRESIDENT (End: 07/30/2015) WHITE, DIANA, SECRETARY (End: 07/30/2015) HOLMBERG, KANDICE K, SECRETARY (End: 07/30/2015) VARRIANO, JON S, TREASURER (End: 07/30/2015) Doing business as HOLMBERG COMPANY WA UBI No. 174 003 387 15400 SE 30TH PL, SUITE 100 BELLEVUE, WA 98007 425-822-2233 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HOLMBC*066ME Effective — expiration 07/05/1994— 09/01/2019 Bond HANOVER INSURANCE COMPANY THE Bond account no. 1959086 Received by L&I 07/18/2011 Bond history Insurance ......................... American Fire & Casualty Co Policy no. BKA55653106 Active. Meets current requirements. $12,000.00 Effective date 09/01/2011 Expiration date Until Canceled $1,000,000.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=174003387&LIC=HOLMBC*066ME&SAW= 8/14/2017 HOLMBERG COMPANY Received by L&I Effective date 07/24/2017 09/01/2013 Expiration date 09/01/2018 Insurance history Savings ....................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 15-2-00439-2 Complaint filed by DJ MECHANICAL INC Complaint date 03/13/2015 Dismissed Complaint against bond(s) or savings 1959086 Complaint amount $49,186.06 L&I Tax debts .._.................................. No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 104,069-02 ..............................:.. Doing business as HOLMBERG CO Estimated workers reported Quarter 2 of Year 2017 "76 to 100 Workers" L&I account contact T1 / JAN BENTLEY (360)902-4652 - Email: STR0235@lni.wa.gov Track this contractor Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid ..................._.........._......................................_.................. No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/17/2013 Inspection no. 316854116 Location 1906 NE 45th Seattle, WA 98105 Inspection results date 04/03/2012 Inspection no. 315796003 Location 1415 5th Avenue Seattle, WA 98101 Violations No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=174003387&LIC=HOLMBC*066ME&SAW= 8/14/2017 MECHANICAL LEGEND REFERENCE SYMBOLS AHU NEW MECHANICAL WORK ENLARGED PLAN BORDER DETAIL OR DRAWING IDENTIFIER EQUIPMENT IDENTIFIER POINT OF CONNECTION PLUMBING SL LL C DOMESTIC COLD WATER DOMESTIC HOT WATER HOT WATER RECIRC SANITARY SEWER ABOVEGROUND SANITARY SEWER UNDERGROUND VENT PIPING RAIN WATER LEADER OVERFLOW RAIN WATER LEADER HVAC PIPING REFRIGERATION PIPING - SUCTION REFRIGERATION PIPING - LIQUID CONDENSATE DRAIN HEATING WATER RETURN HEATING WATER SUPPLY GAS HWR HWS G FIRE PROTECTION FM FIRE SPRINKLER MAIN PIPING ELEMENTS MV4 ISI 0 CO BALL VALVE GLOBE VALVE RELIEF/SAFETY VALVE AUTOMATIC AIR VENT (EXTEND DISCHARGE TO DRAIN) DIRECTION OF FLOW STRAINER WITH BLOW OFF VALVE UNION HOSE BIBB FLOOR DRAIN, FLOOR SINK, AREA DRAIN CLEAN-OUT (FLOOR) PIPE CONTINUES PIPE CAP o PIPE RISING UP PIPE DROPPING DOWN DUCTWORK COMBINATION FIRE/SMOKE DAMPER ` (CFSD) / \ Y V. MANUAL VOLUME DAMPER MOTOR OPERATED DAMPER DUCT SMOKE DETECTOR RECTANGULAR DUCT UP RECTANGULAR DUCT DOWN ROUND DUCT UP ROUND DUCT DOWN GRD SYMBOLS [21 SUPPLY DIFFUSER RETURN OR RELIEF GRILLE EXHAUST GRILLE CONTROLS VFD 0 VARIABLE FREQUENCY DRIVE DIRECT DIGITAL CONTROL PANEL CONTROL WIRING ROOM THERMOSTAT ROOM SENSOR SHUTOFF DAMPERS OUTSIDE AIR SUPPLY, EXHAUST OPENINGS, RELIEF OUTLETS, STAIRWAY AND SHAFT VENTS AND RETURN OPENINGS USED FOR AIRSIDE ECONOMIZER SHALL BE PROVIDED WITH CLASS I MOTORIZED DAMPERS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE C403.2.4.3. CLASS I DAMPERS SHALL HAVE A MAXIMUM LEAKAGE RATE OF 4 CFM/SQ.FT. @ 1.0" W.C. SEE DRAWINGS FOR DAMPER LOCATIONS. OUTSIDE AIR INTAKE OPENING LOCATION 1. INTAKE OPENINGS SHALL BE LOCATED A MINIMUM OF 20 FEET FROM LOT LINES OR BUILDING ON THE SAME LOT. WHERE OPENINGS FRONT ON A STREET OR PUBLIC WAY, THE DISTANCE SHALL BE MEASURED TO THE CENTERLINE OF THE STREET OR PUBLIC WAY. 2. MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 10 FEET HORIZONTALLY FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE. EXCEPT AS NOTED IN ITEM 3. 3. INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 3 FEET BELOW CONTAMINANT SOURCES WHERE SUCH OPENINGS ARE LOCATED WITHIN 10 FEET OF THE OPENING. 4. INTAKE OPENINGS ON STRUCTURES IN FLOOD HAZARD AREAS SHALL BE AT OR ABOVE DESIGN FLOOD LEVEL. 5. ENVIRONMENTAL AIR (RELIEF AIR) SHALL BE A MINIMUM OF 3 FT FROM OPERABLE OPENINGS INTO BUILDING FOR ALL OCCUPANCIES OTHER THAN GROUP U AND 10 FEET FROM MECHANICAL AIR INTAKES. MECHANICAL ABBREVIATIONS 0 DIAMETER, PHASE L LENGTH A AIR LAT LEAVING AIR TEMPERATURE MV AUTOMATIC AIR VENT LB POUND ABV ABOVE LL REFRIGERANT LIQUID LINE AD AREA DRAIN, ACCESS DOOR LVR LOUVER ADA AMERICANS WITH DISABILITIES ACT LWT LEAVING WATER TEMPERATURE AFF ABOVE FINISHED FLOOR MAT MIXED AIR TEMPERATURE AHJ AUTHORITY HAVING JURISDICTION MAX MAXIMUM AHU AIR HANDLING UNIT MBH THOUSANDS OF BTUH APPROX APPROXIMATE MECH MECHANICAL ARCH ARCHITECT MED MEDIUM R-3.3. DUCTWORK LOCATED IN UNCONDITIONED SPACES SHALL BE INSULATED AMERICAN SOCIETY OF HEATING, REFRIG. MERV MINIMUM EFFICIENCY REPORTING VALUE ASHRAE AND AIR-CONDITIONING ENGINEERS, INC. MIN MINIMUM B BOILER MISC MISCELLANEOUS BDD BACKDRAFT DAMPER MPG MEDIUM PRESSURE GAS BF BELOW FLOOR MU MAKEUP WATER BFF BELOW FINISHED FLOOR (N) NEW BLDG BUILDING NA NOT APPLICABLE BLW BELOW NEG NEGATIVE BOD BOTTOM OF DUCT NO NORMALLY OPEN BOP BOTTOM OF PIPE NO. NUMBER BOT BOTTOM NP NON -POTABLE C CONDENSATE PIPING NTS NOT TO SCALE CAP CAPACITY OA OUTSIDE AIR CBV CIRCUIT BALANCING VALVE OAT OUTSIDE AIR TEMPERATURE CD CEILING DIFFUSER OCC OCCUPIED CFM CUBIC FEET PER MINUTE OSA OUTSIDE AIR CL CENTER LINE PD PRESSURE DROP CLG CEILING PERF PERFORATED CO CLEANOUT PH PHASE COND CONDENSATE PIV POST INDICATOR VALVE CONN CONNECTION POC POINT OF CONNECTION CU CONDENSING UNIT, CUBIC PRESS PRESSURE CV CHECK VALVE, CONSTANT VOLUME PRV PRESSURE REDUCING VALVE CW DOMESTIC COLD WATER PSI POUNDS PER SQUARE INCH DB DRY BULB PU PUMP DEPT DEPARTMENT QTY QUANTITY IN FRONT OF ANY ELECTRICAL PANEL, INCLUDING PANELS ON EQUIPMENT. R REFRIGERANT PIPING DF DFU DRINKING FOUNTAIN DRAINAGE FIXTURE UNIT RA RETURN AIR DIFF DIFFERENTIAL RAF RETURN/RELIEF AIR FAN DIM DIMENSION RAG RETURN AIR GRILLE DN DOWN RCP REFLECTED CEILING PLAN DX DIRECT EXPANSION RD REF ROOF DRAIN REFERENCE, RETURN/EXHAUST FAN DWG DRAWING (E) EXISTING REL RELIEF EA EACH, EXHAUST AIR RET RETURN EAT ENTERING AIR TEMPERATURE RG RETURN GRILLE ECG EGGCRATE GRILLE RH ROOF HOOD EF EXHAUST FAN RM ROOM EFF EFFICIENCY ROD . ROOF OVERFLOW DRAIN EG EXHAUST GRILLE RPBA REDUCED PRESSURE BACKFLOW ASSEMBLY ELEC ELECTRIC RPBP REDUCED PRESSURE BACKFLOW PREVENTER ELEV ELEVATION RPM REVOLUTIONS PER MINUTE EMCS ENERGY MANAGEMENT CONTROL SYSTEM RTU ROOFTOP UNIT ENT ENTERING SA SUPPLY AIR ESP EXTERNAL STATIC PRESSURE SAD SUPPLY AIR DIFFUSER EWT ENTERING WATER TEMPERATURE SCH SCHEDULE EX EXHAUST S/D SMOKE DAMPER EXT EXTERIOR, EXTERNAL SF SUPPLY FAN, SQUARE FOOT °F DEGREES FAHRENHEIT SG SUPPLY GRILLE FC FLEXIBLE CONNECTOR SL REFRIGERANT SUCTION LINE FCO FLOOR CLEANOUT SMACNA SHEET METAL AND AIR CONDITIONING FD FLOOR DRAIN CONTRACTORS' NATIONAL ASSOCIATION, INC. F/D FIRE DAMPER SP STATIC PRESSURE FLA FULL LOAD AMPS SPEC SPECIFICATION FLR FLOOR SQ SQUARE FLEX FLEXIBLE SUP SUPPLY FPM FEET PER MINUTE TAB TESTING, ADJUSTING AND BALANCING FS FLOOR SINK TEMP TEMPERATURE F/S/D COMBINATION FIRE SMOKE DAMPER TG TRANSFER GRILLE FDIC FURNISHED BY OWNER, INSTALLED TPRV TEMPERATURE/PRESSURE RELIEF VALVE .. I Y of Tukwila BY CONTRACTOR TSP TOTAL STATIC PRESSURE FV FACE VELOCITY T'STAT THERMOSTAT G GAS TYP TYPICAL GAL GALLON UNOCC UNOCCUPIED GC GENERAL CONTRACTOR V VENT, VOLTS GPM GALLONS PER MINUTE VAV VARIABLE AIR VOLUME UNIT GR GRILLE VD VOLUME DAMPER GRD GRILLES, REGISTERS, AND DIFFUSERS VEL VELOCITY GWH GAS WATER HEATER VENT VENTILATION, VENTILATOR HB HOSE BIBB VFD VARIABLE FREQUENCY DRIVE HC HEATING COIL VTR VENT THRU ROOF HD HEAD W WASTE, WATT, WIDTH HOR HORIZONTAL WCO WALL CLEANOUT HP HEAT PUMP, HORSEPOWER W/O WITHOUT HVAC HEATING, VENTILATION & AIR CONDITIONING WPD WATER PRESSURE DROP HW DOMESTIC HOT WATER WSEC WASHINGTON STATE ENERGY CODE HWC DOMESTIC HOT WATER CIRCULATING WSFU WATER SUPPLY FIXTURE UNIT I.E. INVERT ELEVATION WT WEIGHT KW KILOWATT WTD WATER TEMPERATURE DROP MECHANICAL LEGEND REFERENCE SYMBOLS AHU NEW MECHANICAL WORK ENLARGED PLAN BORDER DETAIL OR DRAWING IDENTIFIER EQUIPMENT IDENTIFIER POINT OF CONNECTION PLUMBING SL LL C DOMESTIC COLD WATER DOMESTIC HOT WATER HOT WATER RECIRC SANITARY SEWER ABOVEGROUND SANITARY SEWER UNDERGROUND VENT PIPING RAIN WATER LEADER OVERFLOW RAIN WATER LEADER HVAC PIPING REFRIGERATION PIPING - SUCTION REFRIGERATION PIPING - LIQUID CONDENSATE DRAIN HEATING WATER RETURN HEATING WATER SUPPLY GAS HWR HWS G FIRE PROTECTION FM FIRE SPRINKLER MAIN PIPING ELEMENTS MV4 ISI 0 CO BALL VALVE GLOBE VALVE RELIEF/SAFETY VALVE AUTOMATIC AIR VENT (EXTEND DISCHARGE TO DRAIN) DIRECTION OF FLOW STRAINER WITH BLOW OFF VALVE UNION HOSE BIBB FLOOR DRAIN, FLOOR SINK, AREA DRAIN CLEAN-OUT (FLOOR) PIPE CONTINUES PIPE CAP o PIPE RISING UP PIPE DROPPING DOWN DUCTWORK COMBINATION FIRE/SMOKE DAMPER ` (CFSD) / \ Y V. MANUAL VOLUME DAMPER MOTOR OPERATED DAMPER DUCT SMOKE DETECTOR RECTANGULAR DUCT UP RECTANGULAR DUCT DOWN ROUND DUCT UP ROUND DUCT DOWN GRD SYMBOLS [21 SUPPLY DIFFUSER RETURN OR RELIEF GRILLE EXHAUST GRILLE CONTROLS VFD 0 VARIABLE FREQUENCY DRIVE DIRECT DIGITAL CONTROL PANEL CONTROL WIRING ROOM THERMOSTAT ROOM SENSOR SHUTOFF DAMPERS OUTSIDE AIR SUPPLY, EXHAUST OPENINGS, RELIEF OUTLETS, STAIRWAY AND SHAFT VENTS AND RETURN OPENINGS USED FOR AIRSIDE ECONOMIZER SHALL BE PROVIDED WITH CLASS I MOTORIZED DAMPERS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE C403.2.4.3. CLASS I DAMPERS SHALL HAVE A MAXIMUM LEAKAGE RATE OF 4 CFM/SQ.FT. @ 1.0" W.C. SEE DRAWINGS FOR DAMPER LOCATIONS. OUTSIDE AIR INTAKE OPENING LOCATION 1. INTAKE OPENINGS SHALL BE LOCATED A MINIMUM OF 20 FEET FROM LOT LINES OR BUILDING ON THE SAME LOT. WHERE OPENINGS FRONT ON A STREET OR PUBLIC WAY, THE DISTANCE SHALL BE MEASURED TO THE CENTERLINE OF THE STREET OR PUBLIC WAY. 2. MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 10 FEET HORIZONTALLY FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE. EXCEPT AS NOTED IN ITEM 3. 3. INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 3 FEET BELOW CONTAMINANT SOURCES WHERE SUCH OPENINGS ARE LOCATED WITHIN 10 FEET OF THE OPENING. 4. INTAKE OPENINGS ON STRUCTURES IN FLOOD HAZARD AREAS SHALL BE AT OR ABOVE DESIGN FLOOD LEVEL. 5. ENVIRONMENTAL AIR (RELIEF AIR) SHALL BE A MINIMUM OF 3 FT FROM OPERABLE OPENINGS INTO BUILDING FOR ALL OCCUPANCIES OTHER THAN GROUP U AND 10 FEET FROM MECHANICAL AIR INTAKES. FIRE SPRINKLER GENERAL NOTES 1. FIRE SPRINKLER SYSTEM ISA PERFORMANCE SPECIFICATION. CONTRACTOR IS RESPONSIBLE FOR FULLY COMPLIANT SYSTEM DESIGN AND INSTALL. 2. DIAGRAMMATIC ROUTING OF CONCEALED PIPING IS FOR REFERENCE ONLY. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE ROUTING WITH OTHER TRADES; PROVIDE PIPE OFFSETS AND COVERAGE AS REQUIRED. PIPING AND HEAD LOCATIONS SHALL NOT OBSTRUCT ACCESS TO MECHANICAL EQUIPMENT ABOVE CEILINGS. 3. PROVIDE SPRINKLER PROTECTION FOR ALL AREAS OF THE BUILDING INCLUDING VOID SPACES, CEILING SPACES, ATTIC SPACES, ETC. IN COMPLIANCE WITH NFPA 13 REQUIREMENTS. 4. SPRINKLER SYSTEM SHALL COMPLY WITH REQUIREMENTS OF NFPA 13 AND AUTHORITY HAVING JURISDICTION (AHJ), CITY OF TUKWILA FIRE MARSHALL. 5. SPRINKLER CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES PRIOR TO INSTALLATION. HVAC WORK SHALL TAKE PRECEDENCE. SPRINKLER PIPING INSTALLED WITHOUT PROPER COORDINATION SHALL BE SUBJECT TO REMOVAL AND REINSTALLATION AT NO COST. 6. FIRE SPRINKLER CONTRACTOR SHALL PROVIDE COMPLETE SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO SUBMITTING TO THE JURISDICTION. 7. ALL EXPOSED SPRINKLER PIPING SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. THERE SHALL BE NO EXPOSED PIPING IN OCCUPIED FINISHED SPACES UNLESS APPROVED BY ARCHITECT. SPRINKLER PIPING INSTALLED WITHOUT PROPER COORDINATION AND APPROVAL SHALL BE SUBJECT TO REMOVAL AND REINSTALLATION AT NO COST. 8. PROVIDE SEISMIC FLEXIBLE PIPE CONNECTIONS TO SPRINKLER HEADS IN CEILINGS. 9. MAINTAIN FIRE AND SMOKE RATINGS OF WALLS. REVISIONS No changes shall be made to the scope of work withott prior approval of Tukwila Building Division. POT,: n3L iS ano viii require a new plan submittal and may include additinn,I p! 'n review Ices. J MECHANICAL SHEET LIST: MECHANICAL GENERAL NOTES: 1. STANDARD CURRENT TRADE PRACTICES & METHODS APPLY TO THIS PROJECT. TYPE PROVIDING SETPOINT TEMPERATURES, NIGHT SETBACK, MANUAL TM0.02 ALL WORK IS TO MEET REQUIREMENTS OF ALL CURRENT CODE & LOCAL OVERRIDE, & MINIMUM 5 -DEGREE DEADBAND. CONTROLS SHALL ALLOW FOR TM0.03 JURISDICTIONAL REQUIREMENTS AND AMENDMENTS. THESE CODES INCLUDE OPTIMUM START. TMCF.01 BUT ARE NOT LIMITED TO WASHINGTON STATE ENERGY CODE, INTERNATIONAL TMCF.02 MECHANICAL CODE, INTERNATIONAL BUILDING CODE, UNIFORM PLUMBING 25. HEAT PUMPS WITH AUXILIARY ELECTRIC HEAT SHALL HAVE CONTROLS TMCF.03 CODE, NFPA, INTERNATIONAL FIRE CODE, & LOCAL JURISDICTIONAL . COMPLYING WITH WSEC C403.2. TM1.01 REQUIREMENTS. COMPLY WITH ALL MANUFACTURER'S REQUIREMENTS. TM2.01 COORDINATE WITH OWNER'S REPRESENTATIVE FOR ANY VARIANCES. 26. SEAL & TEST ALL DUCTWORK AS REQUIRED PER IMC, WSEC C403.2.8.3 TM3.01 HVAC FLOOR PLAN LEAKAGE REQUIREMENTS, & IBC VAPOR RETARDER REQUIREMENTS. 2. DRAWINGS ARE DIAGRAMMATIC ONLY & NOT INTENDED TO SHOW ALL DETAILS DUCTWORK DESIGN PRESSURE IS 2". TM7.01 OF THE WORK. VERIFY LOCATION & MEASUREMENTS OF ALL ITEMS ON THE JOB TM9.01 SITE PRIOR TO INSTALLATION. CONTRACTOR SHALL PROVIDE ALL OFFSETS & 27. ALL SHEET METAL DUCTWORK SHALL BE INSULATED IN ACCORDANCE WITH TM9.02 ADDITIONAL DUCTWORK & PIPING AS NECESSARY TO AVOID STRUCTURAL THE WASHINGTON STATE ENERGY CODE. CONCEALED DUCTWORK LOCATED ELEMENTS ON THE PROJECT. CONTRACTOR SHALL PRODUCE SHOP WITHIN THE CONDITIONED SPACE SHALL BE INSULATED WITH A MINIMUM OF DRAWINGS & COORDINATE WITH OTHER TRADES. THERE SHALL BE NO R-3.3. DUCTWORK LOCATED IN UNCONDITIONED SPACES SHALL BE INSULATED ADDITIONAL COST TO THE OWNER FOR THIS COORDINATION OR FOR EXTRA WITH A MINIMUM OF R-6. WHERE LOCATED OUTSIDE OF THE BUILDING, MATERIAL REQUIRED IN ORDER TO ACCOMPLISH THIS TASK. DUCTWORK SHALL BE INSULATED WITH A MINIMUM OF R-8. 3. PROVIDE COMPLETE & FULLY -OPERATING SYSTEMS. 28. SOUND -LINE ALL SUPPLY, RETURN, OR EXHAUST DUCT WITHIN 10' OF FANS UNLESS NOTED OTHERWISE. 4. COORDINATE LOCATIONS OF ALL EQUIPMENT & APPURTENANCES WITH OTHER TRADES. 29. ALL SHEET METAL PRODUCTS SHALL COMPLY WITH SMACNA DUCT IT I II FrAl CONSTRUCTION STANDARDS, CURRENT EDITION. 5. ALL EQUIPMENT SHALL BE REGULARLY CATALOGED ITEMS OF THE MANUFACTURER & SHALL BE SUPPLIED AS A COMPLETE UNIT IN ACCORDANCE 30. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE GALVANIZED SHEET METAL WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS. ANY OPTIONAL UNLESS NOTED OTHERWISE. ROUND DUCT SHALL BE SHEET METAL. PROVIDE ITEMS REQUIRED FOR PROPER INSTALLATION SHALL BE INCLUDED UNLESS TURNING VANES IN ALL ROUND 2 -PIECE AND RECTANGULAR 90 DEGREE OTHERWISE NOTED. ELBOWS. 6. ANY CUTTING, PATCHING & PAINTING OF BUILDING ELEMENTS & FINISHED 31. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. SURFACES IS TO BE DONE BY THE GENERAL CONTRACTOR. 32. WHERE FLEXIBLE DUCT IS SHOWN AT GRILLES, REGISTERS, AND DIFFUSERS, 7. ALL APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY PROVIDE 6' MAXIMUM LENGTH OF FLEXIBLE DUCT. FASTENED IN PLACE. 33. PROVIDE FLEXIBLE CONNECTORS AT DUCT CONNECTIONS TO ALL AIR 8. ALL EQUIPMENT SHALL BE LABELED PER PLANS & THE REQUIREMENTS OF THE . HANDLING EQUIPMENT. SPECIFICATIONS. 34. SUPPORT FOR SUSPENDED EQUIPMENT SHALL INCLUDE APPURTENANCES AS 9. RATING OF ACCESS DOORS AND/OR ACCESS PANELS THROUGH FIRE -RATED NOTED IN ASHRAE AND REQUIRED IN CODE FOR SEISMIC/SWAY BRACING. WALLS, SHAFTS, CEILINGS, ETC., MUST EQUAL THE FIRE RATING OF THE MATERIAL PENETRATED. 35. PROVIDE VOLUME DAMPERS AT ALL GRILLES, REGISTERS, & DIFFUSERS. 10. CAULK & FLASH ALL PENETRATIONS PER CODE. 36. MOTORIZED DAMPERS SHALL BE CLASS 1 AND HAVE A MAXIMUM LEAKAGE RATE OF 4 CFM/SQUARE FOOT AT 1.0" W.G. 11. ADJUSTING & BALANCING: ADJUST EACH PART OF SYSTEM TO ENSURE PROPER FUNCTIONING OF ALL CONTROLS & SPECIFIED AIR DISTRIBUTION. LEAVE 37. REFERENCE BUILDING HVAC LOAD CALCULATIONS FOR EQUIPMENT ENTIRE SYSTEM IN OPERATING CONDITION. CAPACITIES. NO HUMIDIFICATION PROVIDED. NO SIMULTANEOUS HEATING/COOLING ALLOWED. 12. PROVIDE OPERATING & MAINTENANCE MANUALS (O&MS), RECORD DRAWINGS, & OWNER TRAINING PER WSEC. 38. CONTROLS SHALL CLOSE ALL OSA DAMPERS WHEN EQUIPMENT IS NOT RUNNING IN COMPLIANCE WITH C403.2.4.3 13. PROVIDE NATIONAL ELECTRICAL CODE (NEC) MINIMUM WORKING CLEARANCE IN FRONT OF ANY ELECTRICAL PANEL, INCLUDING PANELS ON EQUIPMENT. RE-ROUTE OR OFFSET PIPING AND/OR DUCTWORK AS REQUIRED. 14. HEAT -TRACED SYSTEMS SHALL MEET THE INSULATION THICKNESS REQUIREMENTS OF THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. UNTRACED PIPING WITHIN A HEAT -TRACED SYSTEM SHALL BE INSULATED WITH NOT LESS THAN 1" OF INSULATION. 15. SERVICE WATER PIPING INSULATION CONDUCTIVITY IS NOT TO EXCEED 0.27 BTU PER INCH. INSULATION THICKNESS SHALL BE PER TABLE C403.2.9. 16. PROTECT PIPING INSULATION PER REQUIREMENTS OF WSEC C403.2.9.1 17. PROVIDE COMMISSIONING OF THE HVAC SYSTEM. INCLUDE FUNCTIONAL TESTING SEQUENCE OF OPERATION & TEST PROCEDURES PER WASHINGTON,.. STATE ENERGY CODE. SEE SPECIFICATIONS FOR SPECIFIC EQUIPMENT TESTING REQUIREMENTS. ITEMS TO BE COMMISSIONED ARE: CONTROL -,0 / i lJ s SYSTEMS, AIR HANDLERS, HEAT PUMPS, EXHAUST FANS, PUMPS, AND WATER HEATERS. AIR SYSTEMS SHALL BE BALANCED SO AS TO FIRST MINIMIZE Flan review approval is subject to errors and omissions. THROTTLING LOSSES, THEN ADJUSTED TO MEET DESIGN FLOW CONDITIONS. PROVIDE PRELIMINARY AND FINAL COMMISSIONING REPORTS. SUBMIT FIGURE Approval of construdreion documents doesnot authorize C408.1.2.1 COMPLIANCE CHECKLIST FROM WASHINGTON STATE ENERGY CODE the violation of any adopted code or ordinance. Receipt TO AUTHORITY HAVING JURISDICTION UPON COMPLETION OF PRELIMINARY COMMISSIONING REPORT. PROVIDE CLOSEOUT DOCUMENTS IN COMPLIANCE of approved Field Copy and conditions is acknowledged: WITH C103.6 6y' 7 T 18. PROVIDE AIR SYSTEM BALANCING DEVICES, INCLUDING VOLUME DAMPERS, AND ZONE DAMPERS ON TERMINALS AS SHOWN ON PLANS. Date: 77 i /i-� 19. CEILING FANS, EQUIPMENT, DIFFUSERS, & GRILLES SHALL BE COORDINATED City of Tukwila WITH PLACEMENT OF LIGHT FIXTURES. BUILDING DIVISION 20. VENTILATION SHALL BE PROVIDED PER IMC CHAPTER 4. MECHANICALLY VENTILATED SYSTEMS SHALL BE CAPABLE OF REDUCING THE OUTDOOR AIR SUPPLY TO THE MINIMUM REQUIRED BY CHAPTER 4 OF THE IMC. ,__-�___• SEPARATE PERMIT 21. OUTSIDE AIR ECONOMIZERS SHALL INCLUDE AUTOMATICALLY MODULATING RE.OUIRED FOR: OUTSIDE & RETURN/RELIEF AIR DAMPERS ARRANGED TO PROVIDE 100% OF REVIEWED FOR THE DESIGN SUPPLY AIR FLOW, & SYSTEM SHALL INCLUDE CONTROLS FOR0 bhaniGat CODE COMPLIANCE ECONOMIZER OPERATION.Iectrical APPROVED22. AIR ECONOMIZERS ON SYSTEMS GREATER THAN 65,000 BTUH SHALL PROVIDE PARTIAL COOLING WHEN MECHANICAL COOLING IS REQUIRED TO MEET THE Iu Bing as Piping JUN 19 2017 REMAINDER OF THE COOLING LOAD. City of Tukwila 23. PROVIDE COMBINATION FIRE & SMOKE DAMPERS (CFSD)AND/OR FIRE BUIL ?I! G DIVISION .. I Y of Tukwila -...--._- DAMPERS WHERE REQUIRED BY CODE. BUILDING DIVISION 24. TEMPERATURE CONTROLS SHALL BE MINIMUM OF 7 -DAY PROGRAMMABLE FIRE SPRINKLER GENERAL NOTES 1. FIRE SPRINKLER SYSTEM ISA PERFORMANCE SPECIFICATION. CONTRACTOR IS RESPONSIBLE FOR FULLY COMPLIANT SYSTEM DESIGN AND INSTALL. 2. DIAGRAMMATIC ROUTING OF CONCEALED PIPING IS FOR REFERENCE ONLY. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE ROUTING WITH OTHER TRADES; PROVIDE PIPE OFFSETS AND COVERAGE AS REQUIRED. PIPING AND HEAD LOCATIONS SHALL NOT OBSTRUCT ACCESS TO MECHANICAL EQUIPMENT ABOVE CEILINGS. 3. PROVIDE SPRINKLER PROTECTION FOR ALL AREAS OF THE BUILDING INCLUDING VOID SPACES, CEILING SPACES, ATTIC SPACES, ETC. IN COMPLIANCE WITH NFPA 13 REQUIREMENTS. 4. SPRINKLER SYSTEM SHALL COMPLY WITH REQUIREMENTS OF NFPA 13 AND AUTHORITY HAVING JURISDICTION (AHJ), CITY OF TUKWILA FIRE MARSHALL. 5. SPRINKLER CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES PRIOR TO INSTALLATION. HVAC WORK SHALL TAKE PRECEDENCE. SPRINKLER PIPING INSTALLED WITHOUT PROPER COORDINATION SHALL BE SUBJECT TO REMOVAL AND REINSTALLATION AT NO COST. 6. FIRE SPRINKLER CONTRACTOR SHALL PROVIDE COMPLETE SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO SUBMITTING TO THE JURISDICTION. 7. ALL EXPOSED SPRINKLER PIPING SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. THERE SHALL BE NO EXPOSED PIPING IN OCCUPIED FINISHED SPACES UNLESS APPROVED BY ARCHITECT. SPRINKLER PIPING INSTALLED WITHOUT PROPER COORDINATION AND APPROVAL SHALL BE SUBJECT TO REMOVAL AND REINSTALLATION AT NO COST. 8. PROVIDE SEISMIC FLEXIBLE PIPE CONNECTIONS TO SPRINKLER HEADS IN CEILINGS. 9. MAINTAIN FIRE AND SMOKE RATINGS OF WALLS. REVISIONS No changes shall be made to the scope of work withott prior approval of Tukwila Building Division. POT,: n3L iS ano viii require a new plan submittal and may include additinn,I p! 'n review Ices. J MECHANICAL SHEET LIST: TM0.01 MECHANICAL LEGEND, ABBREVIATIONS, GENERAL NOTES & SHEET LIST TM0.02 MECHANICAL SCHEDULES TM0.03 MECHANICAL SCHEDULES TMCF.01 MECHANICAL COMPLIANCE FORMS (WASHINGTON STATE - NREC) TMCF.02 MECHANICAL COMPLIANCE FORMS (WASHINGTON STATE - NREC) TMCF.03 MECHANICAL COMPLIANCE FORMS (WASHINGTON STATE - NREC) TM1.01 PLUMBING FOUNDATION PLAN TM2.01 PLUMBING FLOOR PLAN TM3.01 HVAC FLOOR PLAN TM4.01 MECHANICAL ROOF PLAN TM7.01 FIRE PROTECTION PLAN TM9.01 MECHANICAL DETAILS TM9.02 MECHANICAL DETAILS IT I II FrAl II rolluda architects arch tecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 V V� TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com V 0 J O- _ 5M C^) W VJ z W a. ctI- < 0 J ct Z F - (O!) Q °C) Zm coo O) Q 'S ui o Co N w z 0 V O N J U) O p O O .(000 V = Q 0 CO_ cn -1-joe_ U) N g co W I - d- I- I- I u REVISION DATE Design: Drawn: Checked: Project No. RSH RSH DMNRECEIVED CITY OF TUKWILA 331-16-01 APR 252017 PERMIT CENTER Issuance PERMIT SET Date: 4/14/2017 Drawing Title MECHANICAL LEGEND Drawing Number 0:1 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC TM0.01 LEGEND.DWG N.• N N FAN COIL UNIT SCHEDULE TAG AREA SERVED MANUFACTURER/MODEL FAN HEATING CAPACITY (MBH) COOLING ELECTRICAL REFRIGERANT PIPE LL/SL (IN) DRAIN PIPE (IN) OUTSIDE AIR (CFM) DIMENSIONS (LxWxHT) (INxINxIN) WEIGHT (LBS) REMARKS FLOW (_CFM) ESP (IN WC) HP (HP) MOTOR TYPE MOTOR DRIVE TOTAL CAPACITY (MBH) SENSIBLE CAPACITY (MBH) MCA (A) MOP (A) VOLTAGE/ PHASE V/0 FC -01 DRIVER PREP/LOBBY/OFFICES DAIKIN MBVC1600AA-1 1200 0.90 0.75 ECM DIRECT 34.4 34.6 26.2 87.3 110.0 230/1 3/4" / 3/4" 3/4" 310 21x21x52 125 SEE NOTES FC -02 TRAINING/BREAK ROOM DAIKIN MBVC1600AA-1 1200 0.90 0.75 ECM DIRECT 34.4 34.6 26.2 87.3 110.0 230/1 3/4" / 3/4" 3/4" 310 21x21x52 125 SEE NOTES NOTES: 1) 2) 3) VERTICAL UNIT CONFIGURATION. PROVIDE WITH DAIKIN MODEL CAPF3642D6 CASED COIL, COIL PERFORMANCE AS LISTED. PROVIDE WITH DAIKIN MODEL HKA-15C AUXILIARY HEAT KIT, 15.0 kW, SINGLE POINT KIT. . HEAT PUMP UNIT SCHEDULE TAG UNIT SERVED LOCATION MANUFACTURER/MODEL FAN COMPRESSOR HEATING NOMINAL CAPACITY (MBH) COOLING NOMINAL CAPACITY (MBH) SEER /EER ELECTRICAL SOUND PRESSURE LEVELS (dB(A)) REFRIGERANT PIPE LL (IN) REFRIGERANT PIPE SL (IN) DIMENSIONS (LxWxHT) (INxINxIN) WEIGHT (LBS) REMARKS QTY (#) RATED AMPS (A) QTY (#) RATED AMPS (A) MCA (AMPS) MOP (AMPS) VOLTAGE/ PHASE V/0 HP -01 FC -01 PAD MOUNT DAIKIN DZ16TC-0361A 1 1.2 1 15.3 36.0 36.0 16/12.5 20.3 35 230/1 73 3/8" 7/8" 36x36x39 300 SEE NOTES HP -02 FC -02 PAD MOUNT DAIKIN DZ16TC-0361A 1 1.2 1 15.3 36.0 36.0 16/12.5 20.3 35 230/1 73 3/8" 7/8" 36x36x39 300 SEE NOTES NOTES: 1) COORDINATE 2) PROVIDE ALL ELECTRICAL CONNECTIONS AND OR REQUIREMENTS WITH DIVISION 26. WITH ANCHOR BRACKET KIT, MODEL ABK-20. EXHAUST FAN SCHEDULE TAG AREA SERVED LOCATION MANUFACTURER / MODEL FAN MOTOR DRIVE TYPE DIMENSIONS (LxWxHT) (INxINxIN) WEIGHT (LBS) REMARKS FLOW (CFM) ESP (IN WC) SPEED (RPM) POWER (W) AMPS (A) VOLT/PH (V/0) EF -109 CUSTODIAN 109 CEILING PANASONIC FV-05-11VKSL1 110 0.25 1237 17.6 1.7 120V/1 DIRECT 11x11x8 14 SEE NOTES EF -110 SHOWER 110 CEILING PANASONIC FV-05-11VKSL1 110 0.25 1237 17.6 1.7 120V/1 DIRECT 11x11x8 14 1 & 2 EF -111 WOMEN'S 111 CEILING PANASONIC FV-05-11VKSL1 110 0.25 1237 17.6 1.7 120V/1 DIRECT 11x11x8 14 1 & 2 EF -112 MEN'S 112 CEILING PANASONIC FV-05-11VKSL1 110 0.25 1237 17.6 1.7 120V/1 DIRECT 11x11x8 14 1 & 2 NOTES: 1) PROVIDE WITH NEOPRENE HANGING VIBRATION ISOLATION KIT AND SQUARE TO ROUND ADAPTERS AS NECESSARY. PROVIDE BACKDRAFT DAMPER. 2) PROVIDE WITH MANUFACTURER'S CURB, BIRDSCREEN AND CORRESPONDING DISCHARGE CAP. PUMP SCHEDULE TAG SYSTEM SERVED LOCATION MANUFACTURER / MODEL FLOW (GPM) HEAD (FT) FLUID ELECTRICAL FLA (AMPS), MCA/ MOP (AMPS) DIMENSIONS (LxWxHT) (INxINxIN) OPERATING WEIGHT (LBS) NOTES MOTOR ENCLOSURE HP (HP) RPM (RPM) VOLT/PHASE V/0 DCP-01 DOMESTIC HW BOILER ROOM B&G SERIES PL 8 10 WATER TEFC 1/8 3250 120V/1 N/A N/A 7x5x8 15 1 NOTES: 1) SUSPEND FROM PIPING OR IMMEDIATE STRUCTURE TO RESTRICT MOVEMENT. ELECTRIC WATER HEATER SCHEDULE TAG SYSTEM SERVED LOCATION MANUFACTURER / MODEL CAPACITY (GAL) RECOVERY AT 60°F (GPH) TEMP SETTING (F) CAPACITY (W) CAPACITY STAGES (#) CW INLET (IN) HW OUTLET (IN) ELECTRICAL DIMENSIONS (DIAxHT) (INxIN) OPERATING WEIGHT (LBS) REMARKS VOLTAGE/PHASE (V/0) DWH-01 BUILDING DHW CUSTODIAN 109 A.O.SMITH HPTU-50N 50 70.0 110 2@4500 1 3/4 3/4 230/1 22x63 575 SEE NOTES NOTES: 1) PROVIDE WITH SEISMIC RESTRAINT ELECTRIC WALL HEATER SCHEDULE TAG LOCATION MANUFACTURER / MODEL AIRFLOW (_CFM) ELECTRIC HEATING ELECTRICAL DIMENSIONS (LxWxHT) (INxINxIN) WEIGHT (LBS) NOTES CAPACITY (KW) STAGES (#) FLA (AMPS) MAX FUSE (AMPS) VOLT./PH. (V/0) EWH-01 STORAGE 113 Q -MARK CWH1151DSF 65 750W 1 6.3 15 120V/1 11x4x12 10 SEE NOTES EWH-02 JANITOR 109 Q -MARK CWH3404F 100 3 1 14.5 20 230V/1 16x4x20 22 SEE NOTES NOTES: 1. 750W MODELS; PROVIDE WITH MODEL CWHSM SURFACE MOUNTING FRAME AND MODEL SRAFCTPF TAMPER RESISTANT FRONT COVER. THERMOSTAT SHALL BE INTEGRAL. 2. 3000W MODELS; PROVIDE WITH MODEL CWH35M SURFACE MOUNTING FRAME AND MODEL LFKSFC 14 GAUGE SECURITY FRONT COVER. THERMOSTAT SHALL BE INTEGRAL. EXPANSION TANK SCHEDULE TAG SYSTEM SERVED LOCATION MANUFACTURER / MODEL VOLUME (GAL) ACCEPTANCE VOLUME (GAL) SYSTEM PRESSURE (PSIG) SYSTEM CONN (IN) DIMENSIONS (DIAxHT) (INxIN) OPERATING WEIGHT (LBS) NOTES ET -01 DOMESTIC HW MECH. ROOM AMTROL THERM-X-TROL ST -12-C 6.4 3.2 60 3/4 12x14 20 NOTES 1 & 2 NOTES: 1) PROVIDE WITH SIGHT GLASS AND SEISMIC ANCHOR RESTRAINTS. 2) CONTRACTOR SHALL VERIFY SYSTEM PRESSURE REQUIREMENTS AND CHARGE TANK ON SITE. TRAP PRIMER SCHEDULE TAG MAKE & MODEL NUMBER OF OUTLETS PIPE CONNECTIONS REMARKS INLET OUTLETS TP -4 PPP, PRIME -TIME 4 3/4" 1/2" SEE NOTES NOTES: 1. TRAP PRIMER MANIFOLD. RECESS MOUNT. PLUMBING FIXTURE SCHEDULE ID/NO FIXTURE MANUFACTURER/MODEL NUMBERS HYDROTROL MODEL NUMBER PLUMBING CONNECTIONS NOTES WASTE VENT HW CW P-1, P -1A WATER CLOSET ADA TYPE, MFR., MODEL: WALL HUNG, FLUSH VALVE; AMERICAN STANDARD "AFWALL" NO. 3351.128, EVERCLEAN SURFACE FLUSH VALVE: SLOAN "ROYAL" 111 -ADA, 1.28 -GALLON FLUSH. SEAT: OPEN FRONT, LESS COVER; BENEKE NO. 523SS/CH. HANGER: VERTICAL COMPACT SUPPORT. MISCELLANEOUS: FLUSH CONTROL SHALL BE MOUNTED FOR USE FROM WIDE SIDE OF WATER CLOSET AREA. HANDICAPPED - MOUNTING HEIGHT FROM FLOOR TO TOP OF SEAT SHALL BE A MAXIMUM OF 19" AND MINIMUM OF 17" 4" 2" - 1" A2 P-2 URINAL WALL HUNG; VITREOUS CHINA, HEU URINAL SYSTEM, SLOAN, MODEL WEUS 1000.1001-0.13 FLUSH VALVE: MANUAL HEU FLUSHOMETER 0.13 GPF HANGER: INTEGRAL WITH FIXTURE CARRIER: ZURN FLOOR -MOUNTED PLATE TYPE SINGLE URINAL CARRIER WITH BEARING PLATE Z1222 4" 2" - 1" P-3 LAVATORY TYPE, MFR., MODEL: COUNTER MOUNT, 4" CENTERS, VITREOUS CHINA; AMERICAN STANDARD FAUCET: CHICAGO FAUCETS MODEL NO 802-665CP, SLOW SELF-CLOSING METERING WITH INTEGRAL SPRAY FACE, 4 INCH CENTERS, 0.5 GPM VANDAL RESISTANT; TRAP & TAILPIECE: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P -TRAP WITH CLEANOUT AND TAILPIECE SUPPLIES: LOOSE KEY QUARTER -TURN BALL STOP WITH FLEXIBLE BRAIDED STAINLESS STEEL RISERS; BRASSCRAFT HANGER: FLOOR -MOUNTED WITH CONCEALED ARMS. 2" 1-1/2" 1/2" 1/2" P -3A LAVATORY ADA TYPE, MFR., MODEL: WALL HUNG, 4" CENTERS, VITREOUS CHINA; AMERICAN STANDARD "LUCERNE" NO. 0355.012 FAUCET: CHICAGO FAUCETS MODEL NO 802-665CP, SLOW SELF-CLOSING METERING WITH INTEGRAL SPRAY FACE, 4 INCH CENTERS, 0.5 GPM VANDAL RESISTANT; ADA COMPLIANT. TRAP & TAILPIECE: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P -TRAP WITH CLEANOUT AND TAILPIECE SUPPLIES: LOOSE KEY QUARTER -TURN BALL STOP WITH FLEXIBLE BRAIDED STAINLESS STEEL RISERS; BRASSCRAFT HANGER: FLOOR -MOUNTED WITH CONCEALED ARMS. MISC: PROVIDE INSULATION ON TRAP AND SUPPLIES PER SPECIFICATIONS 2" 1-1/2" 1/2" 1/2" P -4A SHOWER ADA ENCLOSURE BY OTHERS; SEE ARCHITECTURAL PLANS TRIM: POWERS E710 TEMPERATURE/PRESSURE COMPENSATING SHOWER SYSTEM E710-0-0-0-1-0-0 WITH 24" CHROME ADA WALL GRAB BAR SYSTEM, AND 2.5 GPM SHOWER HEAD MISC: CURTAIN ROD AND CURTAIN DRAIN: 2" SHOWER DRAIN 2" 1-1/2" 1/2" 1/2" P-5 SERVICE SINK FLOOR -MOUNTED 12" MOP SERVICE BASIN, FIAT MSB -2424-10. FAUCET: DELTA NO. 28C2383, 8" WALL MOUNT WITH INTEGRAL CHECK STOPS, CAST BRASS, CENTERS ADJUSTABLE, TWO HANDLE, POLISHED CHROME PLATED FINISH, 1/2" IPS BRASS PIPE RIGID PAIL HOOK SPOUT, STAINLESS STEEL WALL GUARD, STAINLESS STEEL BUMPER GUARD, HOSE & HOSE BRACKET 832AA SERIES. 3" 2" 3/4" 314" P-6 KITCHEN SINK SINGLE COMPARTMENT, 18 GAUGE STAINLESS STEEL, 19" x 17.5" x 7.5" DEEP WITH STAINLESS STEEL BASKET STRAINERS; JUST MODEL SL -17519 -A -6R FAUCET: SINGLE -HANDLE DECK -MOUNT WITH ESCUTCHEON AND SPRAY, 8" CENTERS, 1.5 GPM, CHROME; DELTA 400LF-HDF TRAP & TAILPIECE: MCGUIRE OR EQUAL, 1-1/2" CHROME PLATED CAST BRASS P -TRAP WITH CLEANOUT SUPPLIES: QUARTER -TURN ANGLE BALL STOP WITH FLEXIBLE BRAIDED STAINLESS STEEL RISERS; BRASSCRAFT SPEEDI-PLUMB PLUS OR EQUAL BY MCGUIRE OR EASTMAN. 2" 1-1/2" 1/2" 1/2" P..7 CLOTHES WASHER CONNECTION BOX TOP SUPPLY, 2" WASTE CONNECTION, 1/2" BRASS QUARTER -TURN HOT AND COLD WATER VALVES WITH 3/4"HOSE BIBBS, INCLUDING HAMMER ARRESTORS, SEE SPECIFICATIONS 2" 1-1/2" 1/2" 1/2" RECESSED BOX P-8 EYEWASH STATION GUARDIAN G1848LH-L EYEWASH, WALL MOUNTED, AUTOFLOW, 90° SWING -DOWN, TWO GS -PLUS SPAY HEADS, DUST COVER, INTERNAL FLOW CONTROL, FURNISHED WITH IN-LINE STRAINER TO PROTECT VALVE AND SPRAY HEADS FROM DEBRIS IN WATER LINE. - - 1/2" 1/2" HB -1 WALL HYDRANT ACORN HOSE & SUPPLY BOXES 8145 STAINLESS STEEL RECESSED HOSE BOX WITH WALL FLANGE VALVE & STOP BODY IS CAST BRONZE WITH EXPOSED PARTS CHROME -PLATED.- - 3/4" 3/4" WATER HAMMER ARRESTOR SIZING SCHEDULE (BELLOWS) MARK FIXTURE UNITS SIZE HYDROTROL MODEL NUMBER REMARKS 1-11 3/4" 5005 Al 12-32 1" 5010 ' A2 33-60 1" 5020 A3 61-113 1" 5030 A4 114-154 1n 5040 A5 WATER HAMMER ARRESTOR SIZING SCHEDULE (PISTON) 0 MARK FIXTURE UNITS PPP MODEL NUMBER REMARKS 1-11 1/2" SC -500 Al 12-32 3/4" SC -750 A2 33-60 1" SC -1000 A3 61-113 1-1/4" SC -1250 A4 114-154 1-1/2" SC -1500 A5 RUNOUTS TO LAST FIXTURE SHALL NOT BE SMALLER THAN SIZE REQUIRED FOR ARRESTERS CW MAIN HW MAIN TO FIXTURES WATER HAMMER ARRESTERS, VIA ACCESS PANEL ISOLATION VALVES PIPING TO LAST FIXTURE NOTE: USE TABLE 10-1 UNIFORM PLUMBING CODE FOR FIXTURE UNITS, FOR SIZING WATER HAMMER ARRESTERS NOTES: 1. WATER HAMMER TYPE SHALL BE BELLOWS OR PISTON. 2. PROVIDE ISOLATION VALVES AT EACH WHA AS SHOWN. WATER HAMMER ARRESTER DIAGRAM REVIEWED FOR CODE COMPLIANCE APPROVED JUIN 19 2017 Chi of Tukwila BUNG DIVISION 7 0097 rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com O cnQ Z0) 0- ui 0 0 o N REVISION DATE Design: RSH Drawn: RSH Checked: DMM RECEIVED Project No. 331-1-b OF TUKWILA APR 252017 PERMIT CENTER Issuance PERMIT SET Date: 4/14/2017 Drawing Title MECHANICAL SCHEDULES Drawing Number TM0.02 COPYRIGHT© 2015 ROLLUDA ARCHITECTS INC TM0.01 LEGEND.DWG 2 0 N 0 r` 0 N N DUCT CONSTRUCTION SCHEDULE DUCT LOCATION DUCT TYPE DUCT SERVICE PRESSURE CLASS (IN) MIN SMACNA SEAL CLASS DUCT MATERIAL NOTES OUTDOOR EXHAUST EXHAUST FANS 2 C GA DUCT WRAP UNCONDITIONED SUPPLY FAN COIL, FURNACES, HEAT PUMPS AND TERMINAL UNITS 2 B GA DUCT WITHIN CONDITIONED SPACE CONSTANT VOLUME AIR HANDLING UNITS 2 B GA 85.5 VARIABLE VOLUME AIR HANDLING UNITS 4 A GA ROUND AND OVAL RETURN FAN COIL, FURNACES, HEAT PUMPS AND TERMINAL UNITS 2 B GA RIGID BOARD AIR HANDLING UNITS 2 B GA R-7, 1 LAYER, 3 INCH THICK EXHAUST EXHAUST FANS 2 C GA DUCTS AND PLENUMS WITHIN CONDITIONED SPACE FUNCTIONING AS PART OF BUILDING ENVELOPE AIR HANDLING UNITS 2 C GA 88.5 OUTDOOR AIR FAN COIL, FURNACES, HEAT PUMPS AND TERMINAL UNITS 2 C GA 90.2 AIR HANDLING UNITS 2 C GA 89.5 CONDITIONED SUPPLY FAN COIL, FURNACES, HEAT PUMPS AND TERMINAL UNITS 2 C GA 90.2 CONSTANT VOLUME AIR HANDLING UNITS 2 C GA 91.7 VARIABLE VOLUME AIR HANDLING UNITS 4 A GA 91.0 RETURN FAN COIL, FURNACES, HEAT PUMPS AND TERMINAL UNITS 2 C GA 93.0 AIR HANDLING UNITS 2 C GA IN ACCORDANCE WITH NEMA STANDARD MGI. MANUFACTURERS ASSOCIATION (NEMA) DESIGN CLASS SMALL AND MEDIUM AC SQUIRREL -CAGE INDUCTION MOTORS. EXHAUST EXHAUST FANS 2 B GA AIR HANDLING UNITS 2 B GA OUTDOOR AIR FAN COIL, FURNACES, HEAT PUMPS AND TERMINAL UNITS 2 C GA AIR HANDLING UNITS 2 C GA NOTES 1. ALL DUCTWORK SHALL BE CONSTRUCTED, SEALED AND ERECTED IN ACCORDANCE WITH THE IMC AND C403.2.7. DUCT SYSTEMS INSULATION SCHEDULE LOCATION OF DUCT DUCT SYSTEM TYPE DUCT CONFIGURATION INSULATION TYPE MINIMUM R -VALUE, INSULATION THICKNESS NOTES DUCT NOT WITHIN CONDITIONED SPACE SUPPLY, RETURN, EXHAUST MIXED, OUTSIDE, AND TRANSFER AIR DUCTS RECTANGULAR - EXPOSED RIGID BOARD R-7, 1 LAYER, 2 INCH THICK 4 RECTANGULAR - CONCEALED DUCT WRAP R-7, 1 LAYER, 3 INCH THICK 1800 ROUND AND OVAL DUCT WRAP R-7, 1 LAYER, 3 INCH THICK 1200 DUCT WITHIN CONDITIONED SPACE SUPPLY, RETURN, EXHAUST GENERATOR EXHAUST, RELIEF AND TRANSFER AIR DUCTS RECTANGULAR - EXPOSED RIGID BOARD R-3.3, 1 INCH THICK 85.5 RECTANGULAR - CONCEALED DUCT WRAP R-3.3, 1 LAYER, 1-1/2 INCH THICK 86.5 ROUND AND OVAL DUCT WRAP R-3.3, 1 LAYER, 1-1/2 INCH THICK 87.5 MIXED AND OUTSIDE AIR DUCTS RECTANGULAR - EXPOSED RIGID BOARD R-7, 1 LAYER, 2 INCH THICK 85.5 RECTANGULAR - CONCEALED DUCT WRAP R-7, 1 LAYER, 3 INCH THICK 85.5 ROUND AND OVAL DUCT WRAP R-7, 1 LAYER, 3 INCH THICK 89.5 DUCTS AND PLENUMS WITHIN CONDITIONED SPACE FUNCTIONING AS PART OF BUILDING ENVELOPE ALL DUCT TYPES RECTANGULAR RIGID BOARD R -VALUE EQUAL TO BUILDING ENVELOPE, THICKNESS AS REQ. 88.5 ROUND AND OVAL DUCT WRAP R -VALUE EQUAL TO BUILDING ENVELOPE, THICKNESS AS REQ. 88.5 NOTES: 1. INSULATE OUTSIDE, EXHAUST, AND RELIEF AIR DUCTS FROM BUILDING ENVELOPE TO BACKDRAFT/MOTORIZED DAMPER WITH R -VALUE EQUAL TO BUILDING ENVELOPE THICKNESS. 2. REQUIREMENTS APPLY TO THE DUCT TYPE LISTED, WHETHER HEATED OR MECHANICALLY COOLED DUCTS REQUIRING INSULATION SHALL HAVE A VAPOR RETARDER, WITH A PERM RATING NOT GREATER THAN 0.5 AND ALL JOINTS SEALED. 3. R-3.3; 1.0 INCH TO 3.0 LB/FT3 DUCT LINER, MINERAL OR GLASS FIBER BLANKET OF EQUIVALENT TO PROVIDE AND INSTALLED TOTAL THERMAL RESISTANCE OF AT LEAST R-3.3. 4. R-5.3; 2.0 INCH 0.75LB/FT3 MINERAL OR GLASS FIBER BLANKET, 1.5 INCH 1.5 TO 3.0 LB/FT3 DUCT LINER, MINERAL OR GLASS FIBER BLANKET, 1.5 INCH 3.0 TO 7.0 LB/FT3 MINERAL OR GLASS FIBER BOARD OR EQUIVALENT TO PROVIDE AN INSTALLED TOTAL THERMAL RESISTANCE OF AT LEST R-5.3. 5. R-7; 3.0 INCH 0.75LB/FT3 MINERAL OR GLASS FIBER BLANKET, 2.0 INCH 1.5 TO 3.0 LB/FT3 DUCT LINER, MINERAL OR GLASS FIBER BLANKET, 2.0 INCH 3.0 TO 7.0 LB/FT3 MINERAL OR GLASS FIBER BOARD OR EQUIVALENT TO PROVIDE AN INSTALLED TOTAL THERMAL RESISTANCE OF AT LEAST R-7. ENERGY EFFICIENT ELECTRIC MOTORS MINIMUM NOMINAL FULL -LOAD EFFICIENCY SCHEDULE TYPE OF PIPE MINIMUM NOMINAL FULL -LOAD EFFICIENCIES (%) MOTOR HP OPEN MOTORS ENCLOSED MOTORS NOTES NUMBER POLES 2 4 6 2 4 .6 SYNCHRONOUS SPEED (RPM) 3600 1800 1200 3600 1800 1200 1.0 77.0 85.5 82.5 77.0 85.5 82.5 1.5 84.0 86.5 86.5 84.0 86.5 87.5 2.0 85.5 86.5 87.5 85.5 86.5 88.5 3.0 85.5 89.5 88.5 86.5 89.5 89.5 5.0 86.5 89.5 89.5 88.5 89.5 89.5 7.5 88.5 91.0 90.2 89.5 91.7 91.0 10.0 89.5 91.7 91.7 90.2 91.7 91.0 15.0 90.2 93.0 91.7 91.0 92.4 91.7 20.0 91.0 93.0 92.4 91.0 93.0 91.7 25.0• 91.7 93.6 93.0 91.7 93.6 93.0 NOTES: IN ACCORDANCE WITH NEMA STANDARD MGI. MANUFACTURERS ASSOCIATION (NEMA) DESIGN CLASS SMALL AND MEDIUM AC SQUIRREL -CAGE INDUCTION MOTORS. 1. NOMINAL EFFICIENCIES SHALL BE ESTABLISHED DESIGNS A AND B ARE NATIONAL ELECTRIC DESIGNATIONS FOR FIXED FREQUENCY PIPING SYSTEMS INSULATION SCHEDULE TYPE OF PIPE INSTALLATION LOCATION INSULATION (TYPE) PIPE SIZE (INCHES) INSULATION THICKNESS (INCHES) NOTES COLD PLUMBING PIPING INSIDE BUILDING ENVELOPE FIBERGLASS ALL SIZES 1" THICK NOTE 2 OUTSIDE BUILDING ENVELOPE AND BURIED ELASTOMERIC ALL SIZES MULTIPLE LAYERS FOR 1-1/2" TOTAL THICKNESS NOTES 1, 4 HOT PLUMBING PIPING INSIDE BUILDING ENVELOPE FIBERGLASS 1-1/4 INCH AND SMALLER 1" THICK 1 1/2 INCH AND LARGER 1-1/2" THICK NOTE 1 OUTSIDE BUILDING ENVELOPE AND BURIED ELASTOMERIC ALL SIZES MULTIPLE LAYERS FOR 2" TOTAL THICKNESS NOTES 1, 4 COLD HVAC PIPING INSIDE BUILDING ENVELOPE FIBERGLASS 1-1/4 INCH AND SMALLER 1" THICK NOTE 2 1-1/2 INCH AND LARGER 1-1/2" THICK NOTE 2 NOTES: 1. INCREASE THICKNESS OF PIPE INSULATION BY 1/2 INCH WHERE PIPING IS LOCATED OUTDOORS OR OTHERWISE EXPOSED TO AMBIENT AIR. 2. INCLUDE POLYETHYLENE TUBING. 3. INCLUDE MULTI -PLY LAMINATE JACKET. 4. INCLUDE FACTORY APPLIED WEATHERABLE JACKET OR MANUFACTURER RECOMMENDED COATING. • AIR TERMINAL SCHEDULE SYMBOL AIR TERMINAL - SIZES AS NOTED ON PLANS MANUFACTURER/MODEL NO. CEILING DIFFUSER: TITUS MODEL TDC WITH FIXED DISCHARGE FOR INSTALLATION IN T -BAR CEILINGS. PROVIDE 24x12 OR 24x24 PANS AS REQUIRED TO SUIT CEILING PANELS. MANUFACTURER'S STANDARD OFF-WHITE FINISH. STEEL CONSTRUCTION. OINLET CFM ELECTRIC RANGE CEILING RETURN/TRANSFER: TITUS MODEL 50-F 1/2"x1/2"x1/2" EGGCRATE GRILLE FOR INSTALLATION IN T -BAR CEILINGS. PROVIDE 12x24 OR 24x24 PANS AS REQUIRED TO SUIT CEILING PANELS. MANUFACTURER'S STANDARD OFF-WHITE FINISH. PAINT DUCT MATTE BLACK BEHIND GRILLE. OINLET CFM INLET SUPPLY GRILLE: TITUS MODEL 300FL FOR INSTALLATION ON WALL, 3/4" BLADE SPACING, DOUBLE DEFLECTION, INDIVIDUALLY ADJUSTABLE BLADES, FRONT BLADES PARALLEL TO LONG DIMENSION. MANUFACTURER'S STANDARD OFF-WHITE FINISH. ALUMINUM CONSTRUCTION. © CFM MISCELLANEOUS EQUIPMENT SCHEDULE MARK SERVES MANUFACTURER/MODEL NO. REMARKS RH-01 ELECTRIC RANGE ACCUREX XRRS-30 RANGE HOOD W/FIRE SUPPRESSION, PROVIDE UNIT WITH VERTICAL IN-LINE EXHAUST FAN & DISCHARGE, EXHAUST FAN SHALL BE FACTORY CALIBRATED TO DELIVER 390 CFM MAX. HOOD SHALL BE INTERLOCKED WITH RANGE FOR ENABLE/DISABLE. COORDINATE WITH DIVISION 26 FOR ALL ELECTRICAL REQUIREMENTS AND CONNECTION TO UNIT. REVIEWED FOR BODE COMPLIANCE APPROVED !JUN 19 2017 • arty &Tukwila BUILDI ,VISION rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 ,('-'1.% IIIIMIUMIll TRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com REVISION DATE Design: RSH Drawn: RSH Checked: DMM RECEIVED Project. No. 3314OE TUKWILA APR 2 5 2017 PERMIT CENTER Issuance PERMIT SET Date: 4/14/2017 Drawing Title MECHANICAL SCHEDULES Drawing Number TM0.03 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC TM0.01 LEGEND.DWG 0 ti N REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 19 2017 City of Tukwila BUILDING DIVISION tillrr � rn3057 rolluda architects arch tecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com E I— 0 co Cfl Z o Cn ui O CO N 1-- w 0 0 cij—J 0O 00 M � C:6 a 0 N Iz na- .i LL1 I— I— I REVISION DATE Design: Drawn: Checked: Project No. RSH RSH RECEIVED DM"tin" OF TUKWILA 331-16-01 APR 2 5 2017 PERMIT CENTER Issuance PERMIT SET Date: 4/14/2017 Drawing Title MECHANICAL COMPLIANCE FORMS Drawing Number TMCF.03 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC TM0.01 _LEGEND.DWG 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 2 of 2 Energy Recovery (ER) Systems - Service Water Heating and Pool Systems NA 0404.10.4 (Section under 0404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or permanent spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by a 36°F NA 0403.5.3 Energy recovery - cooler/ freezer condensers For buildings with food service, meat or deli departments that have a 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate if condenser ER will be used to pre -heat service water For buildings with a 40,000 sf conditioned floor area and with a 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate if condenser ER will be used to pre -heat service water NA 0403.5.4 Energy recovery - condenser systems For buildings with 24-hour operation and > 1,500,000 Btu/h of heat rejection capacity and design SWH load > 250,000 Btu/h, indicate condenser ER to pre -heat service water; or exception taken. Provide calculations showing the amount of recovered heat that Is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). NA 0404.10 Drain water heat recovery units For systems incorporating drain water ER, indicate system design complies with CSA B55.2 (or CSA 55.1 for Group R); indicate potable waterside pressure loss at design flow is < 10 psi Service Water Heating Energy Use Metering NA 0404.9 SWH energy usage in dwelling units For Group R-2 multi -family buildings with central SWH systems, provide metering of hot water energy usage per dwelling unit; indicate metering and data reporting method NA C409.3.2 SWH equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, with total SWH equipment capacity a 50 kW (z 170,600 Btu/h), verily energy use metering of all SWH equipment will be provided per C409 Additional Efficiency Package Option, Reduced Energy Use In Service Water Heating - Must comply with both provisions to be eligible NA C406.7.1 Eligible building type To comply with additional efficiency package option, verify that z 90% of the conditioned floor area of the building is one or more of the occupancies identified in this section, OR; Provide whole building energy analysis per C407 that demonstrates the SWH load In the building is a 10% of total building energy loads NA C406.7.2 0403.5.4 Load fraction To comply with additional efficiency package option, provide documentation that verifies z 60% of building annual SWH energy is provided by high efficiency sources (heat pump water heater with COP a 3, waste heat recovery, solar water -heating system); For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and design service hot water load > 250,000 Btu/h (per C403.5.4); provide documentation that verifies a 100% of building annual SWH energy is provided by condenser energy recovery or other high efficiency source Documentation and Specific System Requirements to Supporting Commissioning Yes C406.4 Scope of service water heating systems commissioning Indicate that all SWH equipment and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned;+D7 TM0.01 For buildings where the largest SWH system has 7 200,000 Btu/h total output capacity, indicate that all SWH systems regardless of individual capacity are required to be commissioned. NA C408.4.1.3 Scope of pool and permanent spa systems commissioning Indicate that all pool and permanent spa water heating systems regardless of individual capacity are required to be commissioned; Indicate that energy recovery equipment that heats pool water regardless of capacity is required to be commissioned; Identify all pool heating and energy recovery equipment and controls that the WSEC defines as being capable of and / or configured to perform specific functions. Yes C404.13 C408.1.1 C408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate in plans and specifications that Cx per C408 is required for all applicable service water heating systems; Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 Including: narrative description of activites, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); TM0.01 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. TM0.01 Yes 0408.4.1 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems TM0.01 Project Close Out Documentation Yes 0103.6 Documentation and project close out submittal requirements Indicate in plans that project close out documentation and training of building operations personnel is required for all SWH components, equipment and systems governed by this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations TM0.01 REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 19 2017 City of Tukwila BUILDING DIVISION tillrr � rn3057 rolluda architects arch tecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com E I— 0 co Cfl Z o Cn ui O CO N 1-- w 0 0 cij—J 0O 00 M � C:6 a 0 N Iz na- .i LL1 I— I— I REVISION DATE Design: Drawn: Checked: Project No. RSH RSH RECEIVED DM"tin" OF TUKWILA 331-16-01 APR 2 5 2017 PERMIT CENTER Issuance PERMIT SET Date: 4/14/2017 Drawing Title MECHANICAL COMPLIANCE FORMS Drawing Number TMCF.03 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC TM0.01 _LEGEND.DWG TO 4" FDC. SEE CIVIL FOR CONTINUATION. INCOMING 4" FIRE SPRINKLER MAIN, SEE CIVIL DRAWINGS FOR CONTINUATION. 11 2"DCW C4) (13D 4"WUP 2"VUP STORAGE 113 3"WUP 4"W UP TO FCO 2"WUP 4"WUP 2"WUP --\ 2"VUP-, WOMEN 111 LOBBY 101 i 2"VUP 4"WUP TO FD 4"W 2"WUP TO FD 2"VUP 2" DCW SERVICE UP TO CW HEADER 4" FIRE MAIN UP (BY OTHERS) 4"W 4"W r —) 2"W OFFICE 102 4" INCOMING SANITARY MAIN, SEE CIVIL DRAWINGS FOR CONTINUATION. 2" INCOMING DOMESTIC TER SERVICE SE CIVIL DRAWINGS FORCONTINUATION. MEN 112 4"W I.E. = 45.47' PLUMBING FOUNDATION PLAN SCALE : 1/4" = 1'-0" ............ DRIVER PREP 108 3"WUP 2"VUP 2"WUP 11 110 2"WUP 2"VUP 4'W 0 f 2"WUP TO FD 2"W _2".V._.UP =.7 3"W 0 B.7, 3"WUP TO FCO USTODIAN CLST. ,i 109\ 2"W l OFFICE 103 CONFERENCE / TRAINING 104 2"W —E - L_ STORAGE 1 106 2"WUP 2"WUP TO FD 2"VUP 2"WUP 4"WUP T©_FCa..1"...I_ MECH 1 ELEC 107 BREAK ROOM 105 -- --- --- — - -- 2"WUP TO FCO GENERAL NOTES: 1. CONTRACTOR SHALL COORDINATE ALL TRENCHING SO THAT ANY FOOTINGS AND OR COLUMNS ARE NOT IMPACTED. 2. PROVIDE SANITARY WASTE AND VENT CONNECTIONS TO FIXTURES SHOWN AS REQUIRED FOR A FULLY FUNCTIONAL SYSTEM. PLAN NOTES: ONO PIPING WITHIN THIS AREA. ORECESSED SLAB, LOCATE DRAIN AS SHOWN. t. L J N O Mtl REVIEWED FOR CODE COMPLIANCE APPROVED JUN 19 2017 City of Tukwila BUILDING DIVISION S7 m rolluda architects archlecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 cr''' TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 1— O co Q� Zco a� Q Luco o: w 0 0 O 1——.I (1) 0 CI 0 J co M O(Cs oU co M N433 0 {d mcot. D Wf— REVISION DATE Design: Drawn: Checked: Project No. RSH RSH DMM RECEIVED 331-ri1g10F TUKWILA APR 2 5 2017 PERMIT CENTER Issuance PERMIT SET Date: 4/14/2017 Drawing Title PLUMBING FOUNDATION PLAN Drawing Number TM1.01 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC TM1.01 _TB-PLAN.DWG STORAGE 113 2"V DROP "W DN. 1"CW DROP 2"V -DROP 3"W DN. 4/4"H&CW DROP CEO FD-1 II I If I WOMEN--- FD-1 OMEN 2"V DROP /3/4"CW DROP 2"V DN. FM, SEEM7.01 FOR CONTINUATION DDCVA & FIRE SPRINKLER RISER,--- SEE ISER;SEE DETAIL 2"CW HEADER, SEE DETAIL FD -1 2"V DN- 0 P -8 FCO P -1A 1„ FCO D4 L 2"V DR 4"W DN. 1"CW DROP — P-1 P-3 I -0-144.{ A=1/2"V DROP. 2"W D 1/2' CW .DR( 1 /2"H&CW DROP P HB -1 LOBBY 101 AD -1 0❑ OFFICE 102 I: 1" 108 3/4" 2"V DROP 3"W DN. 3/4"H&CW DROP FD -1 2"V DN. —� z 0 0 1 I ` 3/4" OFFICE 103 3/4"CW DROP TI DWH-01 DCP-01 DET -01 HB -1 FCO P-5 II CUST. E — CLST. FD -1 3/4"CW DROP STORAGE 3/4" 106 1 1/4 1 1-1/2"V DROP 2"W DN. 3/4"H&CW DROP MECH ELEC 107 FD -1 1/2"H&CW DN 1-1/2"V DN. 2"V ON. CONFERENCE / TRAINING 104 J 0 B- FCO o C) BREAK ROOM 105 (3) PLUMBING FLOOR PLAN SCALE : 1/4" = 1'-0" HB -1 GENERAL NOTES: 1. PROVIDE SANITARY WASTE, VENT, HOT AND COLD WATER CONNECTIONS TO FIXTURES SHOWN AS REQUIRED FOR A FULLY FUNCTIONAL SYSTEM. 2. COORDINATE ALL PLUMBING WORK W/HVAC & ELECTRICAL SO THAT NO CONFLICTS WITH ROUTING SHALL OCCUR. SEE CORRESPONDING HVAC SHEET FOR ACCESS AND CLEARANCE LOCATIONS. IN GENERAL, ROUTE PLUMBING TIGHT TO WALLS AND STRUCTURE. 3. ALL FLOOR DRAINS, FLOOR SINKS AND AIR GAP DRAIN TRAPS SHALL BE CONNECTED TO TRAP PRIMER. NO EXCEPTIONS. 4. PROVIDE ISOLATION VALVES @ ACCESSIBLE LOCATIONS, ABOVE LAY -IN CEILING OR BEHIND WALL WITH ACCESS PANEL. TYPICAL FOR ALL PLUMBING FIXTURES AND TOILET ROOM GROUPS. 5. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS FOR EXACT MOUNTING HEIGHTS OF ALL PLUMBING FIXTURES. 6. PROVIDE WALL CLEANOUTS AT SINKS UNLESS NOTED OTHERWISE. 2.7) 7. ALL PIPING THAT IS NOT INSULATED PER THE SPECIFICATIONS SHALL BE PROTECTED BY USING THE CUSH-A-CLAMP SYSTEM OR EQUAL PRODUCT AS SPECIFIED. 0 PLAN NOTES: OSEE DETAIL, SHEET M9.01. OHW MAIN SHALL DROP DOWN IN WALL TO WITHIN 24" OF FIXTURE AND RISE BACK UP AS SHOWN. REQUIRED ONLY ON PUBLIC LAVS. mn OO7 REVIEWED FOR CODE COMPLIANCE APPROVED 1 JUN 19 2017 City of Tukwila BUILDING DIVISION r()11 da architects arch tecture planning: interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 A Aer" TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 0 o rn Cl) O 0 0 J co ti0 u) _ o ti— (A _ J N t o n- ncoDw I— d' I— I— Z REVISION DATE Design: Drawn: Checked: Project No. RSH RSH DMM 331-16-01 RECEIVED CITY OF TUKWILA APR 9 91117 Issuance PERMIT CENTER PERMIT SET Date: 4/14/2017 Drawing Title PLUMBING FLOOR PLAN Drawing Number TM2.01 TM2.01 TB-PLAN.DWG CL. N O N- N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC -77 0 113 8"0 200 0 . CEILING EXHAUST FAN, 6"0 EXHAUST UP TO ROOF CAP DISCHARGE, TYP. TYPICAL WOMEN 111 u�7 EF -109 EF -111 SHOWER 110 0 `B.7 CUSTODIAN CLST. 109 6"0 50 48x24 O.A. LOUVER STORAGE of 106 EWH-02 18x12 "11 mil Il'i•" -- I DRIVER PREP 108 EF -112 101 8"0 175 OFFICE 102 B 8x8 x8 'i 3X46' 10x1 175 8"0 200 CONFERENCE / TRAINING 104 O8„0 A 150 OFFICE 103 8"0 200 8"0 200 ._�.)._. FC -020.. J i V:=1 12x12 600 18x12 18x12 /S F/S 12x12 l 12„0 8"0 150 Elimm 18x12 MECH ELEC FC -02 107 ELECTRICAL PANELS BY E,C. TYPICAL FC -01 159/ i 12x12 • © 600 8"0, TYP. T r 8"0 150 8"0 150 BREAK ROOM 105 R L/RLL PIPING, PROVIDE F NAL CONNECTION TO UNITS. TYPICAL OF.2. RH-01 I"1 HP -01 HP -0 10"0 UP TOFOOF DISCHARGE. HVAC FLOOR PLAN SCALE : 1/4" = 11-0" N 2) GENERAL NOTES: 1. COORDINATE LOCATION OF ALL GRILLES, REGISTERS AND OR DIFFUSERS WITH ARCHITECTURAL ELEVATION AND INTERIOR DRAWINGS. PLAN NOTES • • 0 4"0 DRYER VENT UP TO ROOF DISCHARGE CAP. SEE TM4.01. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 19 2011 City of Tukwila BUILDING DIVISION MI74 057 rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 7 A Aft'i-• TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com V Z 0 O J O- _ 5 U m �z U0 Q 0 d O -J C° Co Z 03 J�Q ¢� �z 2Q w J_ c I— E ,12 0 ✓ O IY ui Cl) O c J co00 M ti -s O z • Ecl) N_ 0 1—�NIW—= REVISION DATE Design: RSH Drawn: RSH Checked: DMM Project No. 331-1!EEIVED CITY OF TUKWILA APR 2 5 2017 't IIv11T CENTER Issuance PERMIT SET Date: 4/14/2017 Drawing Title HVAC FLOOR PLAN Drawing Number TM3.01 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC TM3.01 TB-PLAN.DWG 2 r 0 N N E O 0 ROOF CAP EXHAJST DISCHAGE, TYPICAL 0 4"VTR 0 4"VTR 0 D"YER V=NT CAP. FI H T c E SUP`RESSION RANGE OD DIS HARGICAP. REFER MANU ACTURER'S DETAIL. MECHANICAL ROOF PLAN SCALE : 1/4" = 1'-0" N . CD REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 19 2017 City of Tukwila BUILDING DIVISION Mt7 O'057 architects rolluda arch Lecture planning i iter.or design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 ' f: 206-624-4226 A Aftrz TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com REVISION DATE Design: RSH Drawn: RSH Checked: RECEIVED Project NQ T &fItift9fiWILA APR 2 5 2017 iDPf? IT rrnMTCn Issuance PERMIT SET Date: 4/14/2017 Drawing Title MECHANICAL ROOF PLAN Drawing Number TM4.01 TM4.01 TB-PLAN.DWG ti T N N c�F COPYRIGHT m 2015 ROLLUDA ARCHITECTS INC L 0 \, L J 0 JJ F— �_.. _.....f r 1 t \\C ri FIRE PROTECTION PLAN SCALE : 1/4" = 1'-0" L — 4 3 N GENERAL NOTES: 1. FIRE SPRINKLER SYSTEM IS A PERFORMANCE SPECIFICATION. CONTRACTOR IS RESPONSIBLE FOR FULLY COMPLIANT SYSTEM DESIGN AND INSTALL. 2. DIAGRAMMATIC ROUTING OF CONCEALED PIPING SHOWN IS FOR REFERENCE ONLY. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE ROUTING WITH OTHER TRADES; PROVIDE PIPE OFFSETS AND COVERAGE AS REQUIRED. PIPING AND HEAD LOCATIONS SHALL NOT OBSTRUCT ACCESS TO MECHANICAL EQUIPMENT IN ATTICS OR ABOVE CEILINGS. 3. PROVIDE SPRINKLER PROTECTION FOR ALL AREAS OF THE BUILDING INCLUDING VOID SPACES, CEILING SPACES, ATTIC SPACES, ETC. NOT PREVIOUSLY PROVIDED WITH FIRE PROTECTION. 4. SPRINKLER SYSTEM SHALL COMPLY WITH REQUIREMENTS OF NFPA 13 AND AUTHORITY HAVING JURISDICTION. 5. SPRINKLER CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES PRIOR TO INSTALLATION. HVAC WORK SHALL TAKE PRECEDENCE. SPRINKLER PIPING INSTALLED WITHOUT PROPER COORDINATION SHALL BE SUBJECT TO REMOVAL AND REINSTALLATION AT NO COST. 6. FIRE SPRINKLER CONTRACTOR SHALL PROVIDE COMPLETE SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO SUBMITTING TO THE JURISDICTION. 7. PROVIDE SEISMIC FLEXIBLE PIPE CONNECTIONS TO SPRINKLER HEADS IN CEILINGS. 8. SEE DIV 21 SPECIFICATIONS FOR DESIGN GUIDELINES. 9. EXTERIOR BUILDING OVERHANGS LESS THAN 4'-0" DO NOT REQUIRE SPRINKLER PROTECTION. 10. MAINTAIN FIRE AND.SMOKE RATINGS OF WALLS. PLAN NOTES: 1O EXTENT OF FIRE PROTECTION WORK SHALL BE CONTAINED WITHIN THIS AREA. . COORDINATE WITH ARCHITECT FOR FINAL LOCATION OF ALL NEW SPRINKLER HEADS SO AS NOT TO CONFLICT WITH NEW STRUCTURE AND OR REVISED CEILING GRIDS. FIRE PROTECTION DDCVA AND RISER ASSEMBLY, SEE DETAIL 1/TM9.02. Mr7 REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 19 2017 • City of Tukwila BUILDING DIVISION 0 0 5 7 rolluda architects architecture planning I iter or design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226Itt "r111/ .40AF. TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com V z OJ O D 0m VJ Z MJ \ (i)O �/ Q: J � < Co Zcco rn z�� � wg co H w z 0 co co ao rn H C9 0 —J 0 0 00 tiu) rn m a) N W I— I— I— H I REVISION DATE Design: RSH Drawn: RSH Checked: D Project No{,i - IMIVED 1 6 KWILA Issuance APR 2 5 2017 rI[rtRnIT (' MTCD PERMIT SET Date: 4/14/2017 Drawing Title FIRE PROTECTION FLOOR PLAN Drawing Number TM7.01 TM7.01 TB-PLAN.DWG a M O ti N F COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC WALL 1" HOSE CONNECT TO SINK DRAIN HOSE CLAMPS AIR VENT FITTING COUNTER TOP SINK 1" DRAIN HOSE FROM D/W DISHWASHER DRAIN CONNECTION SCALE: NONE CUT 1-1/2" RIGID INSULATION TO FIT. ATTACH WITH DUCT TAPE DUCT TAPE TRAP PRIMER CONNECTION ADJUSTABLE STRAINER HEA STRAINER FINISHED GROUT (BY G.C. SLOPED FLOOR REMOVE STRAINER, STRAINER HEAD, AND FLASHING COLLAR. STORE FOR LATER INSTALLATION P 15-0" MIN. FROM ANY FRESH AIR INTAKE FLASHING FINISHED ROOF y SEE DETAIL 8/A2.02 L VANDAL–PROOF VENT CAP fFLASHING VENT PIPING; SIZE AS NOTED ON PLANS VENT THRU ROOF DETAIL SCALE: NONE CW SUPPLY CAULK CONCRETE BY G.C. FLOOR DRAIN BODY PIPE SIZE AS NOTED ON PLAN DURING CONCRETE POUR (STEP #1) NOTES: FLASHING COLLAR WITH WEEP HOLES CONCRETE BY G.C. BALL VALVE TRAP PRIMER VALVE DISTRIBUTION UNIT ACCESS ON WALL COORDINATE LOCATION W/ G.C. AND ARCHITECTURAL PLAN TO FLOOR DRAINS INSTALL STRAINER, STRAINER HEAD, AND FLASHING COLLAR (SET FINAL ELEVATION) AFTER CONCRETE HARDENS (STEP #2) 1. COMPLETE INSTALLATION OF FLOOR DRAIN AND SETTING OF FINAL ELEVATION WILL NOT BE ALLOWED DURING INITIAL CONCRETE POUR. 2. DO NOT ALLOW GROUT PENETRATE WEEP HOLES AND FILL UP TRAP. FLOOR DRAIN INSTALLATION DETAIL SCALE: NONE NOTES: 1. ALL MATERIALS IN CONTACT WITH WATER TO BE COPPER, BRASS, BRONZE, EPDM, STAINLESS STEEL AND CERTIFIED LEAD FREE. ALL EQUIPMENT TO HAVE FLANGED CONNECTIONS FOR EASE OF REPLACEMENT 2. SECOND PRV IS SMALLER SIZE AND SET AT LOWER PRESSURE FOR TIMES WHEN ONLY A FEW FIXTURES ARE IN USE. THIS ALLOWS PROPER CONTROL OF PRESSURE AND PREVENTS CHATTERING AND WEAR IN THE LARGER PRV WATER HAMMER ARRESTOR 2" AIR GAP FITTING, PIPE DISCHARGE FULL SIZE TO DRAIN L. 2" BUILDING i - SERVICE STRAINER WITH #60 MESH. PROVIDE DRAIN VALVE AND THREADED CAP RPBP RELIEF VALVE SET AT 90 PSI; PIPE TO DRAIN — PRV 80 PSI INLET, 60 PSI OUTLET PRV 80 PSI INLET, 55 PSI OUTLET FLOOR DRAIN 3/4" DRAIN VALVE WITH THREADED CAP GALVANIZED STEEL SLEEVE 1" ABOVE FINISHED FLOOR WITH MODULAR SEAL 2"W BLIND FLANGE SUPPORT PIPE (TYPICAL) FINISHED FLOOR PIPE DISCHARGE FULL SIZE TO DRAIN. CUT ENDS OF PIPING AT 45 DEGREE ANGLE TO REDUCE SPLASHING. MAINTAIN MINIMUM 2 PIPE DIAMETER AIR GAP ABOVE FLOOD RIM 8 DOMESTIC CW HEADER DETAIL TM9.01 SCALE: NONE LINED SHEET METAL CAN; INSIDE CLEAR DIMENSION SAME AS DIFFUSER NECK, SEALED TIGHT FINISHED CEILIN FINISHED CEILIN HOT WATER STOP THERMOMETER (30° - 180°) c'— 120° -- 15" MIN FAUCET LAVATORY COLD FLEXIBLE RISER (TYPICAL) BALL VALVE TEE ESCUTCHEON (TYPICAL) COLD WATER STOP LAVATORY TEMPERING VALVE, AS SPECIFIED; INSTALL SO THAT INTEGRAL CHECK VALVES OPERATE PROPERLY LAVATORY SERVICES INSTALLATION DETAIL SCALE: NONE THERMOSTATIC MIXING VALVE PIPE PER MFR INSTALLATION INSTRUCTION It ASME RATED COMBINATION TEMPERATURE & PRESSURE RELIEF VALVE U rI L PIPE FULL SIZE TO DRAIN W/ 2 PIPE DIA. AIR GAP 3/4" HEAT TRAP AQUASTAT (CONTROL WIRING TO PUMP BY E.G.) DCP-01 1 HEAT TRAP DWH-01 DRAIN VALVE FUNNEL & FLOOR DRAIN - SIZE AS SHOWN ON PLAN FINISHED FLOOR FLEXIBLE DUCT SIZE AS SHOWN ON PLAN CEILING DIFFUSER, REGISTER OR GRILLE NOTE: ONLY USE THIS TYPE OF CONNECTION IN CONSTRICTED CEILING SPACES 7– FLEXIBLE DUCT CEILING DIFFUSER, REGISTER OR GRILLE NOTE: USE THIS TYPE OF CONNECTION WHERE THERE IS ENOUGH CEILING SPACE TO KEEP KINKS OUT OF FLEXIBLE DUCT SUPPLY/RETURN AIR CONNECTION SCALE: NONE J �- DRAIN PAN HWC - SIZE AS SHOWN ON PLAN CW - SIZE AS SHOWN ON PLAN NOTE: WATER HEATERS & EXPANSION TANKS SHALL HAVE SEISMIC SUPPORTS ATTACHED TO STRUCTURE. DET -01 EXPANSION TANK 4" HIGH CONCRETE PAD, 4" WIDER THAN TANK R-10 INSULATING PAD 6 ELECTRIC WATER HEATER DETAIL TM9.01/ SCALE: NONE RECTANGULAR TRUNK DUCT CONICAL TAP ROUND TRUNK DUCT CONICAL TAP CONICAL ENTRY TAP ROUND BRANCH DUCT VOLUME DAMPER MAIN SUPPLY DUCT 45' ENTRY TAP MAIN SUPPLY DUCT VOLUME DAMPER 45° ENTRY TAP NOTES: 1. FOLLOW SMACNA DUCT CONSTRUCTION STANDARDS. 2, ALL BRANCH DUCTS ARE TO HAVE VOLUME DAMPERS. BRANCH CONNECTION SCALE: NONE WASTE & VENT LINE PLUMBING FIXTURE AS SHOWN ON PLAT TRAP COVE II Er l cr \moi DUAL DRAINAGE HOLE/7 CLEANOUT DOMESTIC WATER PIPING ALVE AND SUPPLY COVER ADA TRAP & SUPPLY COVER DETAIL SCALE: NONE •-- FINISHED FLOOR NICKEL BRONZE TOP CAST IRON RISER SIZE AS SHOWN ON PLANS, MATERIAL AS NOTED IN SPECIFICATIONS 1-7-1 III- - I VI 1-- 11.1 V 1 ... III -111_-1_1 I__1 119 11--111----1111--I' 1�...I-I I II � �I 1� I I -I—lI!_ 1. FOR INDOOR APPLICATIONS CONCRETE, CERAMIC TILE, TERRAZZO - USE STANDARD SCORIATED CLEANOUT COVER; CARPET - USE CARPET FLANGE; VINYL - USE CLEANOUT INSERT COVER. 2. FOR EXTERIOR APPLICATIONS, PROVIDE AN 18"x18"x5-1/2" CONCRETE PAD AND A NICKEL BRONZE TOP. THREADED ROD, ATTACH TO STRUCTURE; SEE NOTE 1 TRANSVERSE BRACE, (TYPICAL); SEE NOTE 1 STANDARD CLEVIS HANGER SIZED TO GO AROUND RIGID INSULATION INSERT, WITH CLEVIS CROSS BRACE PIPING INSULATION AS SPECIFIED TYPE 25 BEAM CLAMP OR OTHER SPECIFIED ATTACHMENT MAY REQUIRE ROD STIFFENER; SEE NOTE 1 NUT AND WASHER NOTES: RIGID INSULATION INSERT WITH SHIELD AS SPECIFIED 0 S7 1. SEISMIC BRACING, RIGID OR CABLE, SIZE, SPACING, CABLE ANCHORAGE TO BE SPECIFIED BY MECHANICAL CONTRACTOR'S SEISMIC ENGINEER, FOLLOWING SMACNA RESTRAINT MANUAL. INSULATED PIPE HANGER SCALE: NONE REVIEWED FOR CODE COMPLIANCE APPROVED JUN 1 9 2011 City of Tukwila BUILDING DIVISION rolluda rchrtects arch tecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 4411.1\ TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com VJ z FE3 O J ♦0 m VJ Z O 0 J i- Q 0 I - a. Q0 -J mil "-§ I— I— w z 0 I— I- 0 J co • co O U3� Voi• �S r- I—rI- 0 cc(15O 0 0 00 co �g rn ti rn Co N I a. WI— I— I REVISION DATE Design: RSH Drawn: RSH Checked: DMM Project Noci ivgWILA APR 2 5 2017 e..rlIuu I '.L.Id IL. Issuance PERMIT SET Date: 4/14/2017 Drawing Title MECHANICAL DETAILS Drawing Number TM9.01 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC TM9.01 TB-PLAN.DWG ELECTRIC ALARM BELL LOCATED ON EXTERIOR WALL WITH FIRE ALARM SYSTEM WIRING, SEE ELECTRICAL (41ilDWGS WATER FLOW SWITCH WITH FIRE ALARM SYSTEM WIRING, SEE ELECTRICAL DWGS PRESSURE GAGE (TYP) WET PIPE SPRINKLER SYSTEM ALARM VALVE (TYP) RESTRICTED DRAIN ORIFICE GATE OR BUTTERFLY VALVE WITH VALVE MONITOR (TAMPER) SWITCH WITH FIRE ALARM SYSTEM WIRING, SEE ELECTRICAL DWGS (TYP) EXTERIOR WALL MAIN DRAIN VALVE (TYP) FINISHED GRADE FIRE PROTECTION WATER SERVICE TO FIRE DEPARTMENT CONNECTION, SEE CIVIL PIPE MATERIAL AND FITTINGS AS SPECIFIED TO WET PIPE SYSTEM 2" DRAIN TO SPRINKLER TEST / DRAIN RECEPTOR, SEE DETAIL (TYP) DOUBLE CHECK VALVE ASSEMBLY OS AND Y INDICATING VALVE WITH VALVE MONITOR (TAMPER) SWITCH (TYP) PRESSURE GAGE (TYP) SWING TYPE CHECK VALVE WITH 3/4" STRAIGHT BALL DRIP VALVE (TYP) 24" TO 60" AFF !L � FINISHED FLOOR PIPE SLEEVE AND SEALANT, SEE SLEEVE THROUGH FLOOR DETAIL (TYP) PIPE SUPPORT AND FLOOR PLATE (TYP) .. a • • CONCRETE EXPANSION ANCHOR (TYP) PIPE SLEEVE AND SEALANT AS SPECIFIED, SEE SLEEVE THROUGH FOUNDATION WALL DETAIL (TYP) NOTES: 1. PIPING SHOWN BELOW GRADE IS UNDER FOOTING OR THROUGH FOUNDATION WALL. FIRE SPRINKLER DDCVA & RISER ASSEMBLY SCALE: NONE RETAINING GLAND (TYP) BUILDING EXTERIOR WALL 10'-0" NOT TO EXCEED 18" TO BUILDING FIRE SERVICE RISER, SEE DWGS FOR CONT lel FINISHED FLOOR 1'-0" FINISHED GRADE f DEPTH PER NFPA 24 TO FIRE DEPARTMENT CONNECTION, SEE DWGS FOR CONT PIPE MATERIAL AND FITTINGS AS SPECIFIED RESTRAINING RODS WITH CORROSION -RESISTIVE COATING (TYP) NOTES: 1. COMPLY WITH NFPA STANDARDS. 2. SIZE SLEEVES TO ALLOW RESTRAINING ROD INSTALLATIONS. 3. COMPLY WITH SPECIFIED TRENCH AND BACKFILL REQUIREMENTS. BUILDING FIRE SERVICE ENTRANCE PIPE PIPE SLEEVE AND SEALANT SEE SLEEVE THROUGH WALL DETAIL (TYP) FOOTING 2 FIRE MAIN PENETRATION @ BELOW GRADE WALL SCALE: NONE REVIEWED FOR CODE COMPLIANCE APPROVED JUN 192017 City of Tukwila BUILDING DIVISION' Mt7 DOS 7 rolluda architects architecture planning i iterior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 44-tijfooti\:AF,..Z. TRES WEST EMMINM TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com J Z ZE5 O— _ 5 r0 m vJZ U 0 :: Q D E— aC 0 Z F- F- cnI- 0 m Z co cc cc < 2 wg o co N I— w z 0 0 J 00 N- u. N- 0) CD t J Ili I— I— I REVISION DATE Design: RSH Drawn: RSH Checked: DMM Project No.F I V E D c zKWILA APR 2 5 2017 I Ef1MIT OCYJTC11 Issuance PERMIT SET Date: 4/14/2017 Drawing Title MECHANICAL DETAILS Drawing Number TM9.02 TM9.01 TB-PLAN.DWG 0 M O C) N N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC 60'-0" 16'-2 3/4" 11'-5 1 /4" 5'-7 3/4" 7'-2 3/4" 10'-4 3/4" LOCKERS FOIC BENCH FOIC IlurlIuIll CH ELEC EL 48.14 EYEWASH STATION INSTALLED OVER SINK co 9 STORAGE Ass 4 -EL 47.81 FIRE SUPPRESSION RANGE HOOD, SEE NOTE 4 3 STORAGE Walt AV, VJATVAC,' CARPET FIRE CAB 9 SMART PROJECTION PLAQUE RESTRICTIN USE OF APPLIANCE, SEE N •TE 5 - MECHANICAL ENCLOSURE ENTRY MAT RE EPTI AR A / 5'-1 1/2' LOBBY Ilan CONFERENCE / TRAINING BREAK ROOM S ART 105 PROJECTION OFFICE M 0 EM -1 W/DRAIN RING IN BUZZER SMART PROJECTION SMART PROJECTION LANDING OFFICE LANDING ADA ACTUATOR & CARD READER / 5'-0 1 /4" / / 5'-4 3/4" 5'-4 3/4" 4'-2 1 /2" EL 48.64 Can, 3'-0" GENERAL PLAN NOTES 1. SEE SHEET A9.03 FOR INTERIOR PARTITION TYPES. 2. SEE SHEETS A6.03 FOR INTERIOR FINISH SCHEDULE. 3. SEE SHE 411 S. 4. Fl E S w PPRESSION RANGE HOOD MEET NG WITH VENTILATION TO EXTERIOR. 5. A SURFACE MOUNTED 12"x6" PLASTIC SIGNAGE PLAQUE WITH 1" HT. LETTERS SHALL BE MOUNTED ABOVE THE COUNTER ON EA. SIDE OF THE RANGE APPLIANCE STATING: "NO ROASTING, PAN FRYING OR DEEP FRYING ALLOWED IN OR ON APPLIANCES. PER IMC WASHINGTON STATE AMENDMENTS TABLE 507.1.2". FLOOR PLAN SCALE : 1/4" = 1'-0" 7 - LINE OF ROOF EDGE ABOVE REVIEWED FOR CODE COMPLIANCE APPROVED JUN 19 2017 City of Tukwila BUILDING DIVISION Mr7oos7 RECEIVED CITY OF TUKWILA JUN 06 2011 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 6250 Alex r . Ro u . a TATE OF WASHINGTON 0 (/) Z_ OJ O _ D 0 m (%) z Jho � :51_ W < U)D o- p er O J� ▪ Ao CO M J Ci) c=▪ '`� V=Q°'5 ui5- '''-'1(V I- I- 2 H O II- d- F- h I co D IA I— REVISION DATE MECH. PERMIT REVIEW COMMENTS 6/5/2017 PERMIT CORRECTION LETTER#1 Design: AC Drawn: JL Checked: AC Project No. 331-16-01 Issuance PERMIT SET Date: 3/21/2017 Drawing Title FLOOR PLAN Drawing Number A2.01 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC A2.02-TB-PLAN. DWG TcS cV a ti ' - I L aD N • ,OPEN, FILE CASEWORK ELEVATIONS — FRONT DESK SCALE : 1/2" = 1'-0" ELEVATION — COUNTER SCALE : 1/2" = 1'-0" RB -2 4" TYP, U.N.O SHOWER 110 — NORTH ELEVATION SCALE : 1/2" = 1'-0" RB -2 4" TYP, U.N.O 1 2'-1" SINK EQ E 2'-1" 1" SCRIBE i /"\ r 2'-1" \ /\ / •\ / / \ / X \ / \ N / \ \v/ 0 CV I©©I REF DW —7- / / / / / SINK 2'-0" ONE-PIECE ADA -COMPLIANT ROLL -IN SHOWER. MOUNTING HEIGHTS PER MFR, TYP. T / 0 M CASEWORK ELEVATIONS — BREAK ROOM SOUTH SCALE : 1/2" =1'-0" SHOWER 110 — EAST ELEVATION SCALE : 1/2" = 1'-0" GRAB BAR 3'-1 5/8" RANG /OVEN A SURFACE MOUNTED 12" SIGNAGE PLAQUE WITH 1" SHALL BE MOUNTED ABOV ON EA. SIDE OF THE RANG STATING: "NO ROASTING, P DEEP FRYING ALLOWED IN APPLIANCES. PER IMC WA STATE AMENDMENTS TABL L_ SHOWER HEAD FOLD DOWN ADA COMPLIANT BENCH SHOWER 110 — SOUTH ELEVATION SCALE : 1/2" = 1'-0" / O O " PLASTIC T. LETTERS THE COUNTER APPLIANCE N FRYING OR R ON HINGTON 507.1.2". Xf1 3' 1 1/2" OVEN (3) EQ CABS CASEWORK ELEVATIONS — BREAK ROOM WEST SCALE : 1/2" = 1'-0" Mt7Oo 57 REVIEWED FOR CODE COMPLIANCC APPROVED JUN 19 2017 City of Tukwila BUILDING DIVISIOIL RECEIVED CITY OF TUKWILA SHOWER 110 — WEST ELEVATION JUN 46 2417 SCALE : 1/2" = 1'-0" PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 J z OJ O T 0 00 v/ Z 00 MJ W 1— < T �-- ct aC —J a- 2 T Ct F- 0 CO >- 5 5 2 ui 0o N co W rn 5 REVISION DATE MECH. PERMIT REVIEW COMMENTS 6/5/2017 PERMIT CORRECTION LETTER#1 Design: AC Drawn: JL Checked: AC Project No. 331-16-01 Issuance PERMIT SET Date: 3/21/2017 Drawing Title INTERIOR ELEVATIONS Drawing Number A8.01 A8.01 TB INT ELEVATIONS.DWG 2 N U) rel COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC