Permit M17-0069 - BOEING #9-101 - FAN COIL UNIT, VAV BOX, DUCTWORK AND PIPING
BOEING #9-101 9725 E MARGINAL WAY S MI 7-0069 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT 0003400018 Permit Number: M17-0069 9725 E MARGINAL WAY S BLDG 9-101 Project Name: BOEING #9-101 Issue Date: Permit Expires On: 5/25/2017 11/21/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 CONNIE HARDIN 4600 S 134 PL , SEATTLE, WA, 98168 HOLADAY PARKS INC 4600 S 134 PL , SEATTLE, WA, 98168 HOLADPI379NO Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2017 DESCRIPTION OF WORK: INSTALL (1) FAN COIL UNIT & (1) VAV BOX, ASSOCIATED DUCTWORK & PIPING Valuation of Work: $45,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $821.05 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date:S..--- —(s_ 1 hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this developm: nt• I •• 11: nd__,:a.,...,,,.... � r . to the coni ions attached to this permit. III ♦° a• - . , Signature: Date: c� — ( 7 Print Name:C ((� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 2: ***MECHANICAL PERMIT CONDITIONS*** 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov W6( Mechanical Permit No. �� C (" (' ) 6 9' Project No. Date Application Accepted: J r (..'`-( 7 Date Application. Expires: I (-1 q `-'i (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address. KsCo Assessor's Tax Noe:_3 ` 0D 0 1 Suite Number: Floor: Tenant Name: 4t,4 .c A . _ • , � _� � New Tenant: ❑ Yes Ue.glo PROPERTY OWNER Company Name: C S Name: • 00 'lab ZOLick F 2/6 Z gUU7 Addres%4 00 S l 'i 44// Address` City: t— State�0L Z481 / ;Ph_,tl Ph�Cj to ZSl% J ,7V Fax: -at. ut y rub City: Se State: Zips (//zq CONTACT PERSON — person receiving all project communication Company Name: C S Name: Ofon n P - r,�tn 00 'lab ZOLick F 2/6 Z gUU7 Addres%4 00 S l 'i 44// Tukwila Business License No.: City: t— State�0L Z481 / (/ 0 Ph�Cj to ZSl% J ,7V Fax: -at. ut y rub Ema4Rn tt h c 1(xeL ty,uckc.iJiw- MECHANICAL CONTRACTOR INF RMAT ON Company Name: C S AddressLica S rsu pop City: State: LAIL Ziiq . / J 00 'lab ZOLick F 2/6 Z gUU7 Contr Reg No.Hrnioixp Date: -040/7 Tukwila Business License No.: Valuation of project (contractor's bid prie): $ _ d Si D b ' ct e k(C6 ih° -.A Describe the scope of work in detail: Use: Residential: New Commercial: New Fuel Type: Electric ❑ Gas Replacement Replacement Other: H.MtwliratinnaWnnalc-Applieations On Line \2016 Applications\Mechanieal Permit Application Revised I-4-16.doex Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit t <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic t Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) eta.. fedi t Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-1OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN ORI AGENT: Signature: Print Name: l lrli'1t .0'tV01,Ji l n Day Telephone: Mailing Address:U JD `�� 2 <G►. City H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $821.05 M17-0069 Address: 9725 E MARGINAL WAY S BLDG 9-101 Apn: 0003400018 $821.05 Credit Card Fee $23.91 Credit Card Fee R000.369.908.00.00 0.00 $23.91 MECHANICAL $766.48 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $580.03 PLAN CHECK FEE R000.322.102.00.00 0.00 $153.30 TECHNOLOGY FEE $30.66 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11531 R000.322.900.04.00 0.00 $30.66 $821.05 Date Paid: Friday, May 19, 2017 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 08677G Printed: Friday, May 19, 2017 2:42 PM 1 of 1 CRSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: %1 *fr1- /0 / Type of Inspection: , c, .+`IaL1-/AA e., Address: 972 e /41/4126/A/AL 05 Date Called Special Instructio s: j &. el -10/ 0 CAL& f i g— Date W t : i) / 7 Request r: rig Phone No: 2c6 9 '6 o 3021 gApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 3K- Mei- c -i_ 01.<- (1-K BA-IAA/CZ R PbK1— Inspector: �S Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projct:� tS� i:.1 A� y `" �f��1471644- Ty of Inspection: ' /A � ' e1ii4lk)d'C -- Address: Date Called: Special Instructions: •Date 131, 5'101 Waryte 1 f� 2� a i mm. Requeste : Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1Z1)061-1- inspector: .ai)6 * inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /07- Oa toy, Project: 4/6- Type of Inspection: go v6 -t-+- mgc, en -L_-. /Yl 7,4 //e4 -L. Address: 972 " AT. A /N,L 144 '5 Date Called: efftc/i ,'€CL D Special Instructions: 114-ry edit -44 ' -/b/ /vH 7, Date Wanted: 1.27-)7 m p.m. Requester: ?77 vvt ,tion Sa/ Phone No: 30 `ZO le- ci S'�4 '. ElApproved per applicable codes. E] Corrections required prior to approval. COMMENTS: ? R61G - ,✓ /Yl 7,4 //e4 -L. •� 'CA. P i' efftc/i ,'€CL D i43 -0L4 ?4 91-4- OTff-di< a W , Cc VER h Inspector: ?Lt5 Date: 7:-27117 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit j7-0069 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �F,//� Type of Inspection: Rev # --/A1/oF / -L Address: `% 725 A /n G✓X WY Date Called: Special Instructions: O q--/0/ �,�,� Date Wanted: C a•'U' 76.'`? P•m. Requester: 72rvl /494-rt)1FY Mili< Phone No: 204-Pir-6?-304/ 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: "K - 5a'4L'/611r 0172 lv �c - ,/¢, ®r.c;c' DA-✓vt Inspector: Date: 3/y7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr 'ect: -aC/�I7/0/ T e of Inspection: itic - i J j4i(Ci4A,J/( . Address: /72s--.1" / A/204 r�#L GJ./.5 Date Called: Special Instructions: NZ& 1ef-J' / Date Wanted: d' 2 f a.m. Requester: Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: t' )/ ,jn.40-4,0, 09L. Inspector: Date: 17 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. NEUDORFER ENGINEERS INC. TEST, ADJUST & BALANCE BALANCE REPORT Boeing Building 9-101 Secured Space Seattle, Washington 2017-673 Project Completion Date: 08/15/17 Revision Date: En i;+i;:, `kr WILLIAM C. NEUDORFER CERTIFICATION 2465 Exp. 3/31/19 H: dro%kC 5516 1` Ave S Seattle, WA 98108 Phone (206) 621-1810 Fax (206) 343-9820 Revision Number: RECEIVED CITY OF TUKWILA AUG 25 2011 PERMIT CENTER i 2501 SE Columbia Way, Ste. 4230 Vancouver, WA 98661 Phone (503) 235-8924 Fax (503) 235-8925 vLr7 OOzy ifit Conn -Wag Edi &. Portland www, Weud rrfetE PROJECT LOCATION TABLE OF CONTENTS Cover Report Title Certification Warranty 3 4 5 Terms & Abbreviations 6-7 Executive Summary 8-10 Air Handling Unit 11-19 Fan Coil 20 Coil Test 21 TAB Drawings 22-29 Instrument Calibration 30 eudorier En ,neer Inc. g Engineers Seattle Rolland Report Title CERTIFIED TEST: BALANCE REPORT Project: Boeing Building 9-101 Secured Space Seattle, Washington NEI Job#: 2017-673 Engineer: -- Contractor: Holaday Parks TAB Firm: Neudorfer Engineers Inc 5516 1st Avenue South Seattle, WA 98108 Test Engineer: Andy Eaden Architect: -- 5516 1't Ave S Seattle, WA 98108 Phone (206) 621-1810 Fax (206) 343-9820 3 WILLIAM C. NEUDORFER CEFfTIRCATION 2465 Fxp.3l31U19 2501 SE Colurnbia Way, Ste. #230 Vancouver, WA 98661 Phone (503) 235-8924 Fax (503) 235-8925 Nuo e Eniro s. Inc. Consulting..Enginaara Seam Portland CERTIFICATION The data presented in this report is a record of system measurements and final adjustments that have been obtained in accordance with the current edition of the NEBB Procedural Standards for Testing, Adjusting, and Balancing of Environmental Systems. Any variances from design quantities which exceed NEBB tolerances are noted in the Test-Adiust-Balance Report Project Summary. Significant / Noteworthy Remarks are noted on the General Remarks and General Field Notes pages. Other remarks are noted on individual test sheets. Noted deficiencies are not Neudorfer Engineers responsibility to repair. Prior to issuance of this report, Deficiency Reports are forwarded to our contracted agent. Warranty is limited to one year from date of this report. Within that time, any discrepancies, ambiguities, or omissions found in this report will be retested, adjusted, or balanced as needed. A written notification will be required. Submitted and Certified by: NEBB TAB Firm: Neudorfer Engineers Inc Certification No: 2465 Expiration Date: March 31, 2019 Certification Date: August 15, 2017 (Date completed) Signed and Sealed by: NEBB Supervisor: William C. Neudorfer 4 WILLIAM C. NEUD RFER CERTIFICAT6ON 2465 Exp. 3/31/19 Neudorfer Engineers. Inc. Consulting Engineers $ a Portland Warranty Project: Boeing Building 9-101 Warranty of Services: Neudorfer Engineers, Inc. warrants that the air balancing, evaluated during this performance evaluation are operating at the specified levels as documented within this report At and only this time, and makes no other warranties, stated or implied, concerning the continued performance, operation or safety in the use of this equipment past this time. Neudorfer Engineers warrants the air and hydronic balancing for 1 year from the date of substantial completion. Neudorfer Engineers reserves the right to correct errors or omissions in the collections of data. Warranty Procedures: For all warranty items, Neudorfer Engineers requires written request. The written request should be specific on the areas of concern, such rooms, or equipment, and the type of issue the occupants are experiencing. Once written notification is received, Neudorfer Engineers will schedule a Technician. It is recommended that an Owner or A/E Representative be on site at that time. Voided Warranty and Additional Charges: If a complaint issue is due to a mechanical equipment failure, control or maintenance related, the return trip maybe subject to a service charge, not covered under warranty. Neudorfer Engineers reserves the right to resolve any TAB issue. If a third party or competing Test & Balance Commissioning firm test or adjust any equipment, all project warranty is voided. (This is typical standard for the Mechanical industry, as Manufacture, Mechanical and Control Contractor voids all warranty when a competing firm tests or manipulates their systems.) Any return trips to the job site are subject to a service charge and a purchase order will be required before returning to the job site. Document Archiving An electronic file of all test documents will be kept on file until the end of the Warranty period. During that time and electronic copy of the test data will be provided a no charge. Any additional hard / bound copies requested will be subject to a fee. 5 Nei orter Engin ars. nc. comear,Engtirmaces Seattle Porthowl Terms and Abbreviations Project: Boeing Building 9-101 AC or ACU Air Conditioner or Air Conditioning Unit Act. Actual ACCU Air Cooled Condensing Unit Address Equipment designation number given on the Control Program AH or AHU Air Handler or Air Handling Unit Amps Amperage AP Access Point APP. Application Arr Arrangement AVG Average BHP Brake Horsepower BTU British Thermal Units BTUH British Thermal Units per Hour • CAV Constant Air Volume • CBV Calbirated Balancing Valve (Circuit Setter) CC Cooling Coil CD Ceiling Diffuser CFLA Correct Full Load Amperage CFM Cubic Feet per Minute CH Chiller CHWS Chilled Water Supply CHWR Chilled Water Return Coeff. Coefficient CP Circulating Pump CR Ceiling Register CRAC Computer Room Air Conditioner CRU Computer Room Unit CT Cooling Tower CU Condenser Unit CUH Cabinet Unit Heater CWS Condenser Water Supply CWR Condenser Water Return DAT Discharge Air Temperature DB Dry Bulb DD Direct Drive DDC Direct Digital Controls: EMS Control System for the HVAC Delta Difference, net decrease or increase 6 Des. Dia. Disch. DNL EA EAT Economizer EDC EDH EF EG EMCS ERU E.S.P. Design Diameter Discharge Data Not Listed Exhaust Air Entering Air Temperature Controls and components that allow an air handler to logically utilize outdoor air for cooling as opposed to the use of mechanical cooling. Electric Duct Coil Electric Duct Heater Exhaust Fan Exhaust Grille Energy Management Control System Energy Recovery Unit External Static Pressure Evap. Evaporator EWT Entering Water Temperature FCU Fan Coil Unit FD Fire Damper FH Fume Hood FLA Full Load Amperage: Maximum amperage a motor can draw. Flow Hood Instrument that captures air and converts the reading to CFM. FPB Fan Powered Box FPM Feet per Minute FR Field Report FT Foot, Feet FTU Fan Terminal Unit GPM Gallons per Minute HC Heating Coil HD Pressure Difference across the entering and leaving side of a pump. Heater O.L. Thermal overload protection for motors located at the motor starter (starter heaters) HEPA High Efficiency Particulate Arrestance HOA Hand / Off / Auto Switch HP Horsepower eudarfer Engineer rsutting Enginoots Scotto Portland Inc. Terms and Abbreviations Project: Boeing Building 9-101 HRC Heat Recovery Coil HUH Hydronic Unit Heater HVAC Heating Ventilation and Air Conditioning HWS Heating Water Supply HWR Heating Water Return HX Heat Exchanger HZ Hertz, cycle per second I.D. Inside Diameter in. inches in.w.g. inches of water gauge Kfactor Correction factor to the free area need to calculate CFM. KW Kilowatts LAT Leaving Air Temperature LWG Low Wall Grille LWR Low Wall Register LWT Leaving Water Temperature MAU Make-up Air Hangling Unit MBH 1,000 BTUH MAX. Maximum Flow Requirements for DDC MBH Mega BTUs per hour (1MBH=1,000BTUH) MIN Minimum Flow Requirements for DDC N/A Not Available N/S Not Shown or Specified OA Outside Air OBD Opposed Blade Damper O.D. Outside Diameter PD Pressure Drop. PH Phase PHC Preheat Coil Prim. Primary PSI Pounds per Square Inch RA Retum Air • RAT Return Air Temperature RF Return Fan RH Relative Humidity RHC Reheat Coil RPM Revolutions per Minute RTU Roof Top Unit 7 RVA Rotating Vane Anemometer -reads air velocity in feet per minute SA Supply Air SAT Supply Air Temperature S.F. Service Factor Schedule Design data obtained from the (sched) mechanical prints' schedule of equipment. SCR Silcon Controlled Rectifier Speed Controller SF Supply Fan SFD Smoke/Fire Damper SP Static Pressure Spec(s) Specifications sq.ft. square feet Submittals Submitted data on equipment (subs) capabilities. Suct. Suction SWG Sidewall Grille SWR Sidewall Register TAB Test; Adjust; and Balance Tach Tachometer Tech Technician TSP Total Static Pressure: Difference between the entering and leaving static pressure of a fan. TP Traverse or Test Point UH Unit Heater VAV Variable Air Volume; box that contains a motorized damper that modulates airflow. VD Volume Damper VFD Variable Frequency Drive Velgrid Instrument that reads used to read velocity in feet per minute. VP Velocity Pressure VVT Variable Volume Terminal WC Water Column W.G. Water Gauge WB Wet Bulb do er i r nc. ConsultIng. Engineers atIlk: Portland PROJECT Boeing Building 9-101 Secured Space LOCATION Seattle, Washington EXECUTIVE SUMMARY This project has been balanced per plans and specifications using the National Environmental Balancing Bureau (NEBB) standards and procedures. Neudorfer Engineers performed the air balancing and water balancing on the following: (6) Existing Variable Air Volume Boxes, (1) new supply outlet off of an existing Variable Air Volume Box, and (1) New Fan Coil with a Chilled Water Coil. This fan has been checked for unit data, operating amperage, voltage, rotation, RPM, and operating static pressure. All outlets have been proportioned to ± 10% of design airflow unless otherwise noted. Existing Air Handier (AH2/J2A) • Existing Variable Air Volume Box (AH2/J2A W2/6A) This existing box servers the new secured area on the 2nd Floor of the Boeing Bldg. 9-101. Through the Siemens controls, the controller was commanded to full cooling mode. The primary air was calibrated using the flow hood on the supply grill. Design is 250 CFM and actual is 245 CFM (98% of design total). All overrides were released and the box was put back to normal operation. • Existing Variable Air Volume Box (AH2/J2A VV2/J1A) This existing box servers the new secured area on the 2nd Floor of the Boeing Bldg. 9-101. Through the Siemens controls, the controller was commanded to full cooling mode. The primary air was. calibrated using the flow hood on the supply grills. Design is 825 CFM and actual is 805 CFM (98% of design total). After the supply grills were proportioned and with design tolerance, all overrides were released and the box was put back to normal operation. NATIONAL ENVIRONMENTAL BALANCING BUREAU 8 sln Eng rr eudorfer !neer nc. Portia PROJECT Boeing Building 9-101 Secured Space LOCATION Seattle, Washington EXECUTIVE SUMMARY (CONTD.) Existing Air Handler (AH2/J2A) • Existing Volume Air Volume Box (AH2/J2A VV2/J1B) This existing box servers the new secured area on the 2nd Floor of the Boeing Bldg. 9-101. Through the Siemens controls, the controller was commanded to full cooling mode. The primary air was calibrated using the flow hood on the supply grills. Design is 1,050 CFM and actual is 1,080 CFM (103% of design total). After the supply grills were proportioned and with design tolerance, all overrides were released and the box was put back to normal operation. • - Existing Variable Air Volume Box (AH2/J2A VV2/J2A) This existing 'box servers the new secured area on the 2nd Floor of the Boeing Bldg. 9-101. Through the Siemens controls, the controller was commanded to full cooling mode. The primary air was calibrated using the flow hood on the supply grills. Design is 1,310 CFM and actual is 1,315 CFM (100% of design total). After the supply grills were proportioned and with design tolerance, all overrides were released and the box was put back to normal operation. • Existing Variable Air Volume Box (AH2/J2A VV2/K1 B) This existing box servers the new secured area on the 2nd Floor of the Boeing Bldg. 9-101. Through the Siemens controls, the controller was commanded to full cooling mode. The primary air was calibrated using the flow hood on the supply grills. Design is 700 CFM and actual is 685 CFM (98% of design total). After the supply grills were proportioned and with design tolerance, all overrides were released and the box was put back to normal operation. NATIONAL ENVIRONMENTAL BALANCING BUREAU 9 ire r Inc. C nsulting Engineers SetaI<ti i rliand PROJECT Boeing Building 9-101 Secured Space LOCATION Seattle, Washington EXECUTIVE SUMMARY (CONTD.) Existing Air Handler (AH2/J2A) • Existing Variable Air Volume Box (AH2/J2A VV2/K2A) This existing box servers the new secured area on the 2nd Floor of the Boeing Bldg. 9-101. Through the Siemens controls, the controller was commanded to full cooling mode. The primary air was calibrated using the flow hood on the supply grills. Design is 1,050 CFM and actual is 1,025 CFM (98% of design total). After the supply grills were proportioned and with design tolerance, all overrides were released and the box was put back to normal operation. Existing Air Handler (AH2/J4A) • Existing Variable Air Volume Box (AH2/J4A VV2/J3A) This existing box serves existing supply diffusers, one of the supply diffusers was in the construction bubble for air balancing. Through the Siemens controls, the controller was commanded to full cooling mode. Design on the one supply grill is 240 CFM and actual is 265 CFM (110% of design total). This box was not calibrated and the other diffusers were not read not proportioned. After the one supply grills was set to the design flow, all overrides were released and the box was put back to normal operation. • New Fan Coil (FC -2J1) This new fan coil serves the server room in the secured space of the Boeing Bldg. 9-101. Design is 1,500 CFM and actual is 1,490 CFM (99% of design total). After the supply and return grills were proportioned, the chilled water data was obtained. Refer to the chilled water data sheets for further details. When all the data was documented, all overrides were released and the controller was put back to normal operation. Balancing diagrams are attached to this report with outlets numbered for locations. NATIONAL ENVIRONMENTAL BALANCING BUREAU 10 ., i sa�l¢�g E�rgia Pardand inc. Air Handling Unit PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: Existing Air Handler AH2/J2A AREA: 2nd floor Log: Tested By: Andy Eaden Date: 8/10/2017 Existing Air Handler AH2/J2A 8/8/2017 Andy Eaden Existing air handler, no unit data was obtained. Neudorfer Engineers, Inc. 11 Air Handling Unit PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: Existing Air Handler AH2/J2ANV2/6A AREA: 2nd Floor Secured Conference Room Unit Data Manufacturer VAV Address Application # Cooling Inlet Size Cooling K Factor Titus 5 6621 6 inches 0.58 Tested By: Andy Eaden Date: 8/10/2017 Air 'Test Data Clg Max Des. Primary Flow Clg Min Des. Primary Flow Clg Max Act. Primary Flow Clg Min Act. Primary Flow 250 CFM 250 CFM 245 CFM 245 CFM Existing Air Handler AH2/J2ANV2/6A Supply Outlet Summary System/Unit Area Served Type of Reading Outlet Type Size LxW 1 D AK Design Velocity Design Value Prelim Readinq " Final Reading Final % Remarks Outlet -01 2nd Floor Secured Conference Room Flowhood CD -8B 8 x 8 1 - 250 230 245 98 Totals: - - - - - 250 230 245 98 - Neudorfer Engineers, Inc. 12 Air Handling Unit PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: Existing Air Handler AH2/J2ANV2/J1 A AREA: 2nd Floor Secured Office Space Unit Data Manufacturer Model Number VAV Address Application # Cooling Inlet Size Cooling K Factor Enviro-Tec SSDII 2 6521 10 inches 0.73 Tested By: Andy Eaden Date: 8/10/2017 Air Test Data Clg Max Des. Primary Flow Clg Min Des. Primary Flow Clg Max Act. Primary Flow Clg Min Act. Primary Flow 825 CFM 160 CFM 805 CFM 160 CFM Existing Air Handler AH2/J2ANV2/J1A Supply Outlet Summary System/Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Value; Prelim Reading Final Reading Final % Remarks Outlet -01 2nd Floor Secured Office Space Flowhood CD -8A 8 x 8 1 - 275 270 270 98 Outlet -02 2nd Floor Secured Office Space Flowhood CD -8A 8 x 8 1 - 275 260 260 95 (1) Outlet -03 2nd Floor Secured Office Space Flowhood CD -8A 8 x 8 1 - 275 275 275 100 Totals: - - - - `825 805. 805 98 - Log: Existing Air Handler AH2/J2ANV2/J 1 A/Outlet-02 8/10/2017 Andy Eaden (1 Volume damper is full open. Neudorfer Engineers, Inc. 13 Air Handling Unit PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: Existing Air Handler AH2/J2ANV2/J1 B AREA: 2nd Floor Secured Office Space Unit Data Manufacturer Model Number VAV Address Application # Cooling Inlet Size Cooling K Factor Enviro-Tec SSDII 3 6521 10 inches 0.70 Tested By: Andy Eaden Date: 8/10/2017 Air Test Data Clg Max Des. Primary Flow Clg Min Des. Primary Flow Clg Max Act. Primary Flow Clg Min Act. Primary Flow 1050 CFM 210 CFM 1080 CFM 215 CFM Existing Air Handler AH2/J2ANV2/J1 B Supply Outlet Summary System/Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Value Prelim Reading Final Reading Final % Remarks Outlet -01 2nd Floor Secured Office Space Flowhood CD -8A 8 x 8 1 - 350 400 350 100 (1) Outlet -02 2nd Floor Secured Office Space Flowhood CD -8A 8 x 8 1 - 350 430 360 103 Outlet -03 2nd Floor Secured Office Space Flowhood CD -8A 8 x 8 1 - 350 410 370 106 Totals: - - - •- 1050 1240 1080 103 Log: Existing Air Handler AH2/J2ANV2/J1 B/Outlet-01 8/8/2017 Andy Eaden (1) Volume damper is full open. Neudorfer Engineers, Inc. 14 Air Handling Unit PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: Existing Air Handler AH2/J2ANV2/J2A AREA: 2nd Floor Secured Office Space Unit Data Manufacturer Model Number VAV Address Application # Cooling Inlet Size Cooling K Factor Enviro-Tec SSDII 4 6521 12 inches 0.69 Tested By: Andy Eaden Date: 8/10/2017 Air Test Data Clg Max Des. Primary Flow Clg Min Des. Primary Flow CIg Max Act. Primary Flow CIg Min Act. Primary Flow 1310 CFM 260 CFM 1315 CFM 260 CFM Existing Air Handler AH2/J2ANV2/J2A Supply Outlet Summary System/Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Value Prelim Reading Final Reading `Final % Remarks Outlet -01 2nd Floor Secured Conference Room Flowhood CD -8A 8 x 8 1 - 200 415 200 100 Outlet -02 2nd Floor Secured Office Space Flowhood CD -8A 8 x 8 1 - 370 330 370 100 (1) Outlet -03 2nd Floor Secured Office Space Flowhood CD -8A 8 x 8 1 - 370 375 375 101 Outlet -04 2nd Floor Secured Office Space Flowhood CD -8A 8 x 8 1 - 370 360 370 100 Totals: - - - - 1310 14801315 100 - Log: Existing Air Handler AH2/J2A/VV2/J2A/Outlet-02 8/8/2017 Andy Eaden (1) Volume damper is full open. Neudorfer Engineers, Inc. 15 Air Handling Unit PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: Existing Air Handler AH2/J2ANV2/K1 B • AREA: 2nd Floor Secured Conference Room Unit Data Manufacturer Model Number VAV Address Application # Cooling Inlet Size Cooling K Factor Enviro-Tec SSDII 6 6521 8 inches 0.85 Tested By: Andy Eaden Date: 8/8/2017 Air Test Data Clg Max Des. Primary Flow Clg Min Des. Primary Flow Clg Max Act. Primary Flow Clg Min Act. Primary Flow 700 CFM 140 CFM 685 CFM 140 CFM Existing Air Handler AH2/J2ANV21K1 B Supply Outlet Summary System/Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Value Prelim Reading Final Reading Final % Remarks Outlet -01 2nd Floor Secured Conference Room Flowhood CD -8A 12 x 12 1 - 350 610 345 99 Outlet -02 2nd Floor Secured Conference Room Flowhood CD -8A 8 x 8 1 - 350 285 340 97 (1) Totals: - - - - - 700 895 685 98 - Log: Existing Air Handler AH2/J2ANV2/K1 B/Outlet-02 8/8/2017 Andy Eaden (1 Volume damper is full open. Neudorfer Engineers, Inc. 16 eudorier neer Inc. Consulting Eng:ntors Seattle Thriiancfo Air Handling Unit PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: Existing Air Handler AH2/J2A/VV2/K2A AREA: 2nd Floor Secured Conference Room Unit Data Manufacturer Model Number VAV Address Application # Cooling Inlet Size Cooling K Factor Enviro-Tec SSDII 7 6521 10 inches 0.73 Tested By:. Andy Eaden Date: 8/10/2017 Air Test Data Clg Max Des. Primary Flow Clg Min Des. Primary Flow Clg Max Act. Primary Flow Clg Min Act. Primary Flow 1050 CFM 210 CFM 1025 CFM 210 CFM Existing Air Handler AH2/J2A/VV2/K2A Supply Outlet Summary System/Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Value Prelim Reading Final :Reading Final % Remarks Outlet -01 2nd Floor Secured Conference Room Flowhood CD -8A 8 x 8 1 - 350 375 350 100 Outlet -02 2nd Floor Secured Conference Room Flowhood CD -8A 8 x 8 1 - 350 370 340 97 Outlet -03 2nd Floor Secured Conference Room Flowhood CD -8A 8 x 8 1 - 350 290 335 96 (1) Totals: - - - - - 1050 1035 1025 98 - Log: Existing Air Handler AH 2/J2A/VV2/K2A/Outlet-03 8/8/2017 Andy Eaden (1 Volume damper is full open. Neudorfer Engineers, Inc. 17 eudarier r.. ' r Inc. Consulting Engtnao Ia Portland Air Handling Unit PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: Existing Air Handler AH2/J4A AREA: 2nd floor Log: Tested By: Andy Eaden Date: 8/10/2017 Existing Air Handler AH2/J4A 8/8/2017 Andy Eaden Existing air handler, no unit data was obtained. Neudorfer Engineers, inc. 18 Air Handling Unit PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: Existing Air Handler AH2/J4A/VV2/J3A AREA: 2nd floor Unit Data Manufacturer Model Number VAV Address Application # Cooling Inlet Size Cooling K Factor Enviro-Tec SSDII 2 6521 10 inches 0.71 Log: Tested By: Andy Eaden Date: 8/10/2017 Air Test Data CIg Max Des. Primary Flow CIg Min Des. Primary Flow CIg Max Act. Primary Flow CIg Min Act. Primary Flow 1200 CFM 240 CFM (1) CFM (1) CFM Existing Air Handler AH2/J4ANV2/J3A 8/8/2017 Andy Eaden (1) This an existing VAV box with (4) other supply grills. But the construction bubble only wanted 1 of the 5 existing diffusers balanced to the design CFM on the mechanical print. Existing Air Handler AH2/J4ANV2/J3A Supply Outlet Summary System/Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Value Prelim Reading Final Reading Final % Remarks Outlet -01 2nd floor Flowhood CD -8B 8 x 8 1 - 240 295 265 110 Totals: - - - - - 240 295 - 265 110 - Log: Existing Air Handler AH2/J4ANV2/J3A/Outl et -01 Existing Air Handler A H 2/J 4ANV2/J 3A/O utl et -01 8/8/2017 Andy Eaden The fire smoke damper was not wired for power and not tied into the fire alarm system. The fire smoke damper was manually opened, to complete the air balancing for this outlet. After the air balancing was completed. The fire smoke damper was retumed to the original position and the set screws we're both secured down to the shaft. 8/8/2017 Andy Eaden This an existing VAV box with (4) other supply grills. But the construction bubble only wanted 1 of the 5 existing diffusers balanced to the design CFM on the mechanical print. Neudorfer Engineers, Inc. 19 Fan Coil PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: FC -2J1 AREA: 2nd Floor Secures Server Room Unit Data Unit Manufacturer Unit Model Number Unit Serial Number Unit Location Drive Type Johnson Controls FNP C Server Room Direct Drive Test Data Total Design Flow Total Actual Flow RA Design Flow RA Actual Flow Motor Volts T1-T2 Motor Amps T1 1500 CFM 1490 CFM 1500 CFM 1485 CFM 210 Volts 3.90 (1) Amps Log: Tested By: Andy Eaden Date: 8/10/2017 Motor Data Motor Manufacturer Motor HP Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Genteq (2) 1/3 (2) 1025 (2) 208-230 1 60 2.8 (2) Test Pressures Fan Suction SP Fan Discharge SP Design External SP Actual External SP -0.37 " W.C. (3) " W.C. 0.50" W.C. 0.24 " W.C. Filter Data Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 Koch Pleated 2 16x20x2 FC -2J1 FC -2J1 FC -2J1 8/8/2017 Andy Eaden (3) No access between discharge side of fan and entering side of cooling coil. 8/8/2017 Andy Eaden (1) The actual Amperage is a total from both motors. (2) This fan coil has (2) direct drive motors with the same motor data. .8/8/2017 Andy Eaden FC -2J1 Supply Outlet Summary System/Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Value Prelim Reading Final Reading Final % Remarks Outlet -01 2nd Floor Secures Server Room Flowhood CD- 12A 12 x 12 1 - 750 740 740 99 (1) Outlet -02 2nd Floor Secures Server Room Flowhood CD- 12A 12 x 12 1 - 750 750 750 100 Totals: - - - - - 1500. 1490 1490 99 - Log: FC-2J1/Outlet-01 8/8/2017 Andy Eaden (1 Volume damper is full open. FC -2J1 Return Inlet Summary System/Unit Area Served Type of Reading Outlet Type Size LxW / D AK Design Velocity Design Value Prelim Reading Final Reading Final % Remarks Inlet -01 2nd Floor Secures Server Room Flowhood RG 24 x 24 1 - 750 740 740 99 (1) Inlet -02 2nd Floor Secures Server Room Flowhood RG 24 x 24 1 - 750 745 745 99 Totals: - - - -- 1500 1485 1485 99 - Log: FC-2J1/Inlet-01 8/8/2017 Andy Eaden (1) Volume damper is full open. Neudorfer Engineers, Inc. 20 eudorfe ineer nc,. alii a Enginears Seattle " Portland Coil Test PROJECT: Boeing Bldg. 9-101 Secured Space LOCATION: SEATTLE , WA PROJECT #: 2017-673 DATE: 8/17/2017 CONTACT: Andy Eaden SYSTEM/UNIT: FC -2J1 AREA: 2nd Floor Secures Server Room Unit Data, System Number FC -2J1 Valve Manufacture B&G Valve Model Number 1 L61 Valve Size 1" Coil Location Ceiling Coil Type Chilled Water Tested By: Andy Eaden Date: 8/10/2017 Air Test Data Airflow Design Airflow Actual Ent. Air DB Temp Design Ent. Air DB Temp Actual Ent. Air WB Temp Design Ent. Air WB Temp Actual Leay. Air DB Temp Design Leay. Air DB Temp Actual Leay. Air WB Temp Design Leay. Air WB Temp Actual Air Temp Delta T Design Air Temp Delta T Actual 1500 CFM 1490 CFM 70.0 Deg F 77.2 Deg F 63.0 Deg F 56.2 Deg F 56.0 Deg F 62.6 Deg F 55.3 Deg F 50.2 Deg F 14.0 Deg F 14.6 Deg F Water Test Data CBV Entering PSI CBV Leaving PSI CBV DP Actual CBV Position Water Flow Design Water Flow Actual Ent. Water Temp Design Ent. Water Temp Actual Leay. Water Temp Design Leay. Water Temp Actual Water Delta T Design Water Delta T Actual 42 40 2 100% 6.70 GPM 6.80 GPM 45.0 Deg F 42.6 Deg F 56.0 Deg F 53.4 Deg F 11.0 Deg F 10.8 Deg F Neudorfer Engineers, Inc. 21 A. | { !§ Et , § k :k4 ( ) [ §§■§!7 M; ■. r0 >mO $Q3 co z> zrzz 23Vds aln32s E )11VIA27 n MK) °;i1 V 211 5' glel.5 6 !! RR 6 1 FFFF1111;11P11111 Fl 45AEAlli pH. swzgEmEa REggiRim.n, 1E1141 111011 1111911!!!! 11111 ; F FcF 1 1 gali IMP Pil5E 11"! 1 1r! 14 030111 E: I 01, 11491"5 11111111111 11111111111111r E ; F 3= CO CO 70 Fri g wms...4fio Egmi imEAEEEEEE.glAAPIAAAE'4" AA@EqE0— EIANAiriplAZ P8%9 W5§4' 0"111APEA VCV4' =C) cn 4 EID51901J1 Ogri 111911116M 11111111! 111111Wir MINI Pi!!! q !I :P 00 11'01111H g ' 11 2 A ' ill; EPIP /1 !Ill 11; g 111 116 i; :/ "11 11 11 Ili i! T " "I 5;1 lel 11 1 ;11 01/ F 11 Nit - 111 Ili 1 IQ !! e A ire i di A ! ! ; hp 115 11; a 1 g 11 W 8 ! g.x I ! 11 1 1 Fl E m2 1 .1 E E 4 hp 0 1: zli 4 1 g al 1 q ill 1 4 11 0 AN !IE E Prxi 1 le I!: E r/ AP ! A oXi 6/E ;P ill g 2 1 I! -. 2 ;!; ! IRE i EV 5 ;11 111 i0 1 11 i; p le 1 m.x 6 r e 11 g g Ni 6 7 5 —t1 2 8 8 c Fig 0 0 N f - x 0 0 8 0 6 R' .7L 10/16/0512 85:19 8 8 5 2 8 8 2 8 6 V. 8 8 8 67' 8 8 5 2 8 8 8 8 P1 2 9 6 8 8 8 8 8 8 5 A 8 8 8 3 5 a 8 8 8 8 8 APPP0088 p €€88 5-51 33888888 8 8 8 8988 11/1 8 Oig 8 ilt 8 0 8 8 8 8 8 8 8 8 E. 8 8 8 8 8 8 8 8 8 8 5 8 8 8 8 E KI 8 se 8 8 8 8 8 8 0 8 8 8 8 8 8 8 g 5 0 8 8 5 8 8 8 2 8 8 8 EE 8 8 8 s 8 8 8 0 9 .7.- 8 8 A 8 8 8 8 5. g5 5 8 8 8 8 8 8 8 8 0 8 8 8 8 8 8 ri 5. 8 8 8 5 8 8 8 I 8 G 8 8 8 8 5 8 8 8 5. 8 8 8 8 5 5 8 8 8 8 8 8 8 8 8 8 8 5 8 5 8 5 8 8 8 8 8 i 8 8 8 s 8 8 8`3 2 8 7. 8 i 1 43 e EZ r. G ifi N@ 2 `e 0 1 1 1 1 J p 0) m 0 m 0 0 cn 73 iv 0 z --4 C17 0 0 0 C7 r- -a r- 3 E 2 A 1:P s 6 c e C) W CT .3 tME:li 1IV130 1000 Tf01 MD N01133S G 2 a c) w W U) 0) m m —n0 O 0 N O 0 z A,/ 7,-1 0 :L7 0 • .o 0 —4N cn Em gz 25 05 :NOI1V213d0" JO 30N3f103S mat 3n 13 lMtIe NA FAN SPEED (LOW/MEDIUM/HMI) AIRFLOW (LOW/MEDIUM/MGH) g 1 C � 1 J 5P — _i CURREHY SENSING RELAY i 4 g R b 0 —4N cn Em gz 25 05 :NOI1V213d0" JO 30N3f103S mat 3n 13 lMtIe NA eudorfor Enmeers. Inc. na!ling Enginsora Snaffle Portland Instrument Calibrations Instrument Type Air Data Meter with Flowhood Instrument Manufacturer Shortridge Instrument Model Number ADM 870 Instrument Serial # M97514 Calibration Due Date 3/24/2018 Instrument Type Tachometer Instrument Manufacturer Shimpo Instrument Model Number DT-207LR Instrument Serial # D1520236R Calibration Due Date 4/21/2018 Instrument Type Amp Probe Instrument Manufacturer Fluke Instrument Model Number 324 Instrument Serial # 28680012WS Calibration Due Date 4/21/2018 Instrument Type Temperature Probe Instrument Manufacturer Shortridge Instrument Model Number ADM 870 Instrument Serial # M97514 Calibration Due Date 3/24/2018 Instrument Type Air Foil Instrument Manufacturer Shortridge Instrument Model Number ADM 870 Instrument Serial # M97514 Calibration Due Date 3/24/2018 Instrument Type Hydrometer Instrument Manufacturer Shortridge Instrument Model Number HDM-250 Instrument Serial # W12178 Calibration Due Date 1/23/2018 30 PERMIT COORD COPY: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0069 DATE: 05/19/17 'PROJECT NAME: BOEING #9-101 SITE ADDRESS: 9725 E MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AWC Building Division Public Works /U/4 Fire Prevention Planning Division Structural ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/23/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/20/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: [Permit Center Use. Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC Horne. Espanol Contact Search L&I Page 1 of 3 A -Z Index 1-lelp My Lit Safety & Health Claims & Insurance Workplace Rights Trades & Licensing AlWashington State Departlnent of Labor & industries HOLADAY PARKS INC Owner or tradesperson BECK, DAVID CARL Principals BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUIT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) 4600 S 134TH PL SEATTLE, WA 98168 206-248-9700 KING County WA UBI No. Business type 578 004 089 Corporation 1 1 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 5/25/2017 Help us improve HOLADAY PARKS INC Page 2 of 3 I License I Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HOLADPI379NO Effective — expiration 01/21/1983— 09/03/2017 Bond LIBERTY MUTUAL INS CO Bond account no. 23000452. Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/23/2002 09/01/2002 Expiration date Until Canceled Insurance ............................... Charter Oak Fire Ins Co Policy no. DTCO1 F465357C0F16 $1,000,000.00 Received by L&I . Effective date 10/31/2016 11/01/2016 Expiration date 11/01/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ......................................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 177,231-00 ................................. Doing business as HOLADAY PARKS INC Estimated workers reported Quarter 1 of Year 2017 "Greater than 100 Workers" L&I account representative T3 / REAGAN MOREY (360)902-5135 - Email: MREA235@lni.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/22/2016 Inspection no. 317940948 Location 1007 Stewart St Seattle, WA 98101 No violations Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 5/25/2017 VI CI \ITY VAP PROJECT SITE FROM DOWNTOWN SEATTLE 900 99 EXIT 158 d N EXIT 157 EXIT 157 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE—TACOMA AIRPORT DEVELOPV 599 TUKWILA E\TAL CE\TER FROM KENT & AUBURN NO SCALE 900 SCOPE CF WOR RECONFIGURATION OF EXISTING OFFICE AREA TO SECURE SPACE OFFICE AREA. WORK INCLUDES CONSTRUCTION OF SMALL OFFICE, SERVER ROOM, LARGE MEETING ROOM, AND SECURE SMALL MEETING ROOM, ALONG WITH OPEN OFFICE. MODIFICATIONS TO HVAC, FIRE SPRINKLERS AND POWER/DATA AS REQUIRED BY RECONFIGURATION. ALL NEW PARTITIONS ARE NON—BEARING. BOEING WORKPLACE SERVICES BUILDING 09-101 SECURE SPACE 22J2 BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA VAP 3UILD 9725 EAST TU \G ADDRESS: v1AGI\AL WAY SOUTH 'KWILA, WASHI\GTO\ -85 09-101 3UILDI\ G LOCATIO\ NO SCALE GE\ ERAL \ OTES A CONSTRUCTION SET OF DOCUMENTS, REVIEWED STAMPED BY THE CITY OF TUKWILA BUILDING DEPARTMENT MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. THE GENERAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS WITHIN THE AREA OF WORK BEFORE COMMENCING ANY WORK AND ENSURE THAT THE JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. THE CONTRACTOR SHALL BRING DISCREPANCIES ON THE DRAWINGS OR SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY ONLY IF THEY REQUIRE DESIGN REVISIONS. 2. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS. COORDINATE ALL ROUGH -IN REQUIREMENTS FOR MATERIALS OR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS PROJECT. 3. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED OR WILL BE REMOVED PRIOR TO THE BEGINNING OF THE WORK FOR THIS PROJECT. A COPY OF THE REPORT OF THE SURVEY WILL BE FURNISHED TO THE CONTRACTOR AT THE TIME OF BIDDING OR NEGOTIATIONS. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THE WORK AREA. CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DISCOVERED OR DAMAGED THAT IS REQUIRED TO BE REMOVED TO SUPPORT THE WORK OF THIS PROJECT. 4. THE GENERAL CONTRACTOR SHALL OBTAIN AND MAINTAIN A FULL SET OF CONSTRUCTION DOCUMENTS ON SITE. THIS SET SHALL BE MARKED UP (RED—LINED) DAILY WITH ANY ACTUAL WORK OR INSTALLATIONS DIFFERING FROM THE CONSTRUCTION DOCUMENTS. SAID SET SHALL BE TURNED OVER TO THE BOEING CONSTRUCTION PROJECT MANAGER AT THE COMPLETION OF THE WORK FOR INCORPORATION INTO BOEING RECORD DOCUMENTS. DESIG\ TEA/ OWNER: CONTACTOR AND STATE NO. ARCHITECT MECHANICAL ELECTRICAL BOEING DEVELOPMENT CENTER P.O. BOX 3707 M/C 46-88 SEATTLE, WA 98124 PROJECT CONTACT JOHN MURDOCH 253-740-0214 THE BOEING COMPANY BOEINC* 294ML (01.18.2018) ROLLUDA ARCHITECTS 105 SOUTH MAIN STREET, SUITE 323 SEATTLE, WASHINGTON 98104 ERIC CRANSTON (425) 624-4222 FSI CONSULTING ENGINEERS 506 SECOND AVENUE, SUITE 700 SEATTLE, WASHINGTON 98104 CHRIS HALLOCK (206) 622-3321 CASNE ENGINEERING 10604 NE 38TH PLACE, SUITE 205 KIRKLAND, WASHINGTON 98033 STEVEN GARRL I I (425) 522-1000 CODE SUNv1AY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT TUNNEL FIRST FLOOR MEZZANINE SECOND FLOOR BUILDING GROSS AFFECTED AREA BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC DESIGN CATEGORY: WIND EXPOSURE: TUKWILA 2015 I.B.C. CODES AND THE WAC 51-20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUP B AND GROUP F, DIVISION 1 (OFFICE AND FACTORY) TYPE II—B, NON—COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 1,116,306 (UNLIMITED PER IBC 507.3) 713,829 50,910 713,829 55,689 295,878 1,116,306 EXISTING OFFICE AREA OF APPROXIMATELY 4,155 SQ. FT. GROUP B OCCUPANCY 111 FT. MAXIMUM 2 OVERALL (NO CHANGES) BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT D C SEPARATE PERMIT REQUIRED FOR: 0 Mechanical ellectrical LIumbing (leas Piping City of Tukwila BUILDING DIVISION - FILE COPY Permit No.. M (7-00 b,7 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved F _.opy • con./ tions is acknowledged: City of Tu . DRAWI\G I\DEX SHEET NO. SHEET NAME ARCHITECTURAL 09-101—GO 09-101—G1 09-101-2A01 09-101-2Al2R 09-101-2Al2 09-101-2A282 09-101—A220 09-101—A350 09-101—A580 MECHANICAL 09-101—M1 D 09-101-2M12R 09-101-2M262R 09-101-2M12 09-101-2M62 09-101-2M262 09-101—M323 09-101—M635 ELECTRICAL 09-101—E1 09-101-2E7CR 09-101-2E12R 09-101-2E62R 09-101—E500R 09-101-2E7C 09-101-2E12 09-101-2E62 09-101—E500 09-101—E505 COVER SHEET SYMBOLS, ABBREVIATIONS & GENERAL NOTES SECOND FLOOR EXITING PLAN PARTIAL FLOOR PLAN — REMOVAL PARTIAL FLOOR PLAN REFLECTED CEILING PLAN WALL SECTIONS DOOR AND HARDWARE SCHEDULES MISCELLANEOUS DETAILS SCHEDULES HVAC DUCTING — REMOVAL FIRE PROTECTION PLAN — REMOVAL HVAC DUCTING HVAC PIPING — SECOND FLOOR PLAN FIRE PROTECTION PLAN SEQUENCE OF OPERATIONS & I/O POINTS FAN COIL DETAILS ELECTRICAL SYMBOLS AND LEGEND DATA OUTLETS — REMOVAL PLAN — LIGHTING — REMOVAL 208Y/120V POWER PLAN — REMOVAL LIGHTING CONTROL DIAGRAM — REMOVAL DATA OUTLETS PLAN — LIGHTING 208Y/120V POWER PLAN LIGHTING CONTROL DIAGRAM LIGHTING CONTROL DIAGRAM REVISIONS No chances shall be made to the scope r'f work withr"..t prior approval of .,,�y Building Division. t`: : j :��53iC ?;, wiil require a new plan submittal and may in;,:ude additional plan review fees. REVISION C F D D A B J E J D E A C J Y C J Y REVIEWED FOR CODE COMPLIANCE APPROVED MAY 232017 YS Log City of Tukwila DUI R s IVISION MF7 004? ISSUE FOR CONSTRUCTION 05.12.17 CITY OF TUKWILA BLANKET PERMIT NO. BPA 16-0008 RECEIVED CITY OF TUKWILA MAY 19 2017 PERMIT CENT PROJECT TITLE: 9-101 SECURE SPACE 22J2 SYM A REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 09-101 BETTERMENTS(WP-1 ENTRY & CANOPY DCA -9-05013 RECORD DRAWING DCA -9-05013 DLR GROUP DLR GROUP LS LM/LS 12.19.05 12.19.08 B 9-101.1 ADC HVAC UPGRADE 21406-W01969369 RAI/AF 10.25.13 C RECORD DRAWING SECURE SPACE 21406-W01969369 33090-12 RAI/AF F.C/ROLLUDA AJC 11.20.14 05.12.17 gli_mEirzw.9 6604 GISTERED HITECT • RIC C STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN ROLLUDA ARCH DATE 11.20.14 CHECKED SUBTITLE COVER SHEET CURRENT REVISION 33090-12 SYMBOL DATE 05.12.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER SECURE SPACE BUILDING 09-101 SHEET GO JOB NO. 33090-12 COMP NO.. DEV. CENTER, WA DWG NO. 09-101—GO 1/28/2013 11:57:52 AM VAIA3LE AR VOLUvE U\IT (vv) NA< SCHEDULE MARK NUMBER VAV— AIR CFMW NUMBER MARK VAV—# AIR CFMW NUMBER MARK VAV—# AIR FLOCFMW MARK NUMBER . VAV—# AIR CFFLOW MARK NUMBER VAV—# AIR CFMFLOW MARK NUMBER VAV— AIR CFMW MARK NUMBER r VAV—# AIR CFMW NUMBER VAV—# AIR CFMW MARK NUMBER VAV—# AIR FLOW CFM 30-33 AH2B2A 11x8 * W2A8A VAV-10 780 W2G 1 A VAV-10 790 W2C6C VAV-6 360 W2F3A VAV-12 1400 W2D16C VAV-12 1500 W2H3B VAV-10 520 PAINTED AH2J4A _ _ _ , W2J8D VAV-10 800 W2A1C VAV-8 150 W2A9A VAV-10 630 W2H1A VAV-10 520 W2C6D VAV-8 740 W2F4A VAV-12 1400 W2D16D VAV-12 1500 W2H4A VAV-12 1400 W2J3A VAV-10 720 EG -10 iAdm. CD -8A 'Y IN T—B' : �� LAY IN T—BAR ST W2A2B VAV-10 980 24 24 35 0 S 715 REP:1 RIO E .'US 'I TIT 50F STEEL W2C7A VAV-12 1480 W2F5A VAV-12 1400 W2D17A VAV-10 720 W2H5A VAV-12 1400 W2J3B VAV-12 1780 17 0.093 489 W2A3B VAV-10 710 STEEL AH2B8A 12x12 14 AH2C5A 20 W2C8A VAV-12 1480 W2D17B VAV-12 1380 W2J3C VAV-12 1200 W2A4B VAV-10 880 W2A6B VAV-10 960 W2C 1 B VAV-12 1050 W2C9A VAV-12 2220 AH2E16A W2D17C VAV-12 1500 AH2G6A W2J4A VAV-12 1500 W2A5B VAV-10 880 W2A7B VAV-10 960 W2C2A VAV-12 1050 W2C 10A VAV-12 900 W2D12A VAV-8 630 W2D17D VAV-12 1500 W2F7A VAV-10 720 W2J4B VAV-12 1350 W2B 1 B VAV-10 600 W2A8B VAV-10 960 W2C3A VAV-12 1500 W2D6A VAV-10 1000 W2D12B VAV-10 720 W2D17E VAV-12 1125 W2F7B VAV-10 720 W2J5A VAV-12 1200 W2B2A VAV-12 950 W2A9B VAV-12 1470 W2C4A VAV-12 1400 W2D6B VAV-8 150 W2D12C VAV-8 480 W2D18A VAV-10 720 W2F7C VAV-10 750 W2J5B VAV-12 1200 W2B2B VAV-10 660 W2B6A VAV-12 1520 W2C5A VAV-12 1400 W2D7A VAV-10 1000 W2D12D . - VAV-8 630 W2E18A \'AV -8 480 W2F7D VAV-12 1200 W2J5C VAV-10 670 W2B3A VAV-12 1400 W2B7A VAV-12 1520 W2D1B VAV-12 1050 W2D7B VAV-10 540 W2D13A r VAV-14 1890 W2E18B \'AV -8 480 W2G7A VAV-12 1500 W2B3B VAV-6 170 W2B8A VAV-12 1520 W2D2A VAV-12 1050 W2D8A VAV-10 1080 W2D13B VAV-10 725 W2F18A VAV-10 1080 W2G7B VAV-12 1500 AH2J7A W2B4A VAV-12 1400 W2B9A VAV-12 1520 W2D3A VAV-12 700 W2D9A VAV-10 1620 W2D14A VAV-10 1080 W2G7C VAV-12 1500 W2J6A VAV-10 910 W2B5A VAV-12 1400 W2B10A VAV-10 680 W2D3B VAV-10 820 W2D10A VAV-10 675 W2D14B VAV-8 630 AH2G3A W2G7D VAV-12 1500 W2J6B VAV-12 1500 W2B1OB VAV-8 710 W2D3C VAV-6 210 W2E9A VAV-12 1200 W2D14C VAV-12 1125 W2G2A VAV-10 1050 W2G7E VAV-12 1500 W2J6C VAV-8 500 AH2B5A W2D3D VAV-6 160 W2D14D VAV-12 1500 W2G2B VAV-10 1050 W2J6D VAV-8 750 W2A1A VAV-8 350 AH2C2A W2D4A VAV-10 1200 AH2E3A W2D14E VAV-12 1500 W2G3A VAV-12 1400 AH2J2A W2J6E VAV-10 1000 W2A1D VAV-6 280 W2A1B VAV-8 320 W2D4B VAV-8 420 W2E2A VAV-10 1050 W2D15A VAV-8 480 W2G4A VAV-12 1400 W2J 1 A VAV-10 800 W2J7A VAV-12 1500 W2A2A VAV-8 280 W2B 1 A VAV-10 780 W2D4C VAV-8 350 W2E2B VAV-10 1050 W2D15B VAV-12 1500 W2G5A VAV-12 1400 W2J 1 B VAV-10 1050 W2J7B VAV-10 1000 W2A3A VAV-10 630 W2B1C WA -6 240 W2D5A VAV-12 1750 W2E3A VAV-12 1400 W2D15C VAV-12 1500 W2H1B VAV-12 1360 W2J2A AV— 1 0 W2J7C VAV-8 690 W2A4A VAV-10 520 W2C 1 A VAV-10 780 W2E4A VAV-12 1400 W2H2A VAV-10 600 W2K 1 A VAV-6A 250 W2J7D VAV-8 430 W2A5A VAV-10 520 W2D 1 A VAV-10 520 AH2C8A W2E5A VAV-12 1400 AH2E17A W2H2B VAV-10 830 W2K 1 B VA —: a ! W2J8A VAV-10 1000 W2A6A VAV-10 780 W2E1A VAV-10 520 W2C6A VAV-6 230 W2F2A VAV-10 1050 W2D16A VAV-10 750 W2H2C VAV-10 800 W2K2A VAV-10 870 W2J8B VAV-10 810 W2A7A VAV-10 520 W2F1A VAV-12 780 W2C6B VAV-6 230 W2F2B VAV-10 1050 W2D16B VAV-10 720 W2H3A VAV-12 880 B t W2J8C VAV-8 800 VAIA3LE AIP VOLUME TEPMI\AL U\IT (VAV) SCHEDULE VAV—# AIR QUANT. RANGE/-7,RANGE CFM PRIMARY AIR PRESSURE DROP INCH WG MAX DISCH NC LEVEL © 1.5" WG INLET TERMINAL SIZE INLET SIZE VAV BOX OUTLET SIZE INCHES REMARKS VAV-6 250-500 0.05 — 0.23 28-33 6 60 8/10 ENVIRO—TEC MDL SSD—II, 1/2" DIAM SHAFT MIN 3" LONG, 90 DEG TURN, NO CONTROLS OR SENSORS VAV-8 500-1000 0.06 — 0.27 30-34 8 80 12/10 ENVIRO—TEC MDL SSD—II, 1/2" DIAM SHAFT MIN 3" LONG, 90 DEG TURN, NO CONTROLS OR SENSORS VAV-10 750-1500 0.05 — 0.18 30-33 10 11x8 * 14/10 ENVIRO—TEC MDL SSD—II, 1/2" DIAM SHAFT MIN 3" LONG, 90 DEG TURN, NO CONTROLS OR SENSORS VAV-12 1000-2000 0.05 — 0.19 33-36 12 14x8 * 18/10 ENVIRO—TEC MDL SSD—II, 1/2" DIAM SHAFT MIN 3" LONG, 90 DEG TURN, NO CONTROLS OR SENSORS 1 . •- ;• ; .4 _: s * LAY IN T—BAR I, PIADIA0 SHAFT MIN 3" LO 95 PEG 'N , • a' '0 -!— , ! D •R SP'_ PAINTED 12 _ _ _ , VAV-6A 250 0.02 — 0.25 17-18 6 60 12x8 TITUS DESV SIZE 6 OVA SIZ VAL GIVEN ARE UPPER LIMIT. AR DIFFUSED / PEGISTEP / GILL (AR) SCHEDULE MARK NUMBER TYPE MATERIAL FINISH INLET / NECK SIZE, INCHES DIFFUSER FLEX DUCT SIZE, INCHES FACE SIZE INCHES MAXIMUM NOISE COEFFICIENT MAXIMUM TP INCH WG MAXIMUM SET CFM REMARKS CD -6 LAY IN T— BAR STEEL PAINTED 6 6 24/24 35 0.06 120 NAILOR—HART SERIES 4600, TYPE RNS2 CD -8 LAY IN T—BAR STEEL PAINTED 8 8 24/24 35 0.13 260 NAILOR—HART SERIES 4600, TYPE RNS2 CD -10 LAY IN T— BAR STEEL PAINTED 10 10 24/24 35 0.18 435 NAILOR—HART SERIES 4600, TYPE RNS2 CD -12 LAY IN T—BAR STEEL PAINTED 12 12 24/24 35 0.20 650 NAILOR—HART SERIES 4600, TYPE RNS2 -- EGGCRATE STEEL PAINTED 24/24 -- 24/24 -- -- 1600 USED FOR RETURN AIR GRILLE, NAILOR—HART 51 ECC OR EQUAL -- EGGCRATE STEEL PAINTED 12/24 -- 12/24 -- 800 USED FOR RETURN AIR GRILLE, NAILOR—HART 51 ECC EG -10 iAdm. CD -8A 'Y IN T—B' : �� LAY IN T—BAR ST PAINTED 10 10 24 24 35 0 S 715 REP:1 RIO E .'US 'I TIT 50F STEEL PAINTED 8x8 10 24/24 25 0.093 489 TITUS MCD WITH 8x8 NECK CD -8B CEILING MOUNTED STEEL PAINTED . 8x8 10 24/24 17 0.093 489 TITUS MCD WITH 8x8 NECK IN TITUS TRM FRAME CD -12A LAY IN T—BAR STEEL PAINTED 12x12 14 24/24 20 0.055 750 TITUS MCD WITH 12x12 NECK FA\ COIL SCHEDULE MARK NUMBER SERVICE COOLING TYPE FREE COOLING EAT (DB/WB) LAT (DB/WB) EWT LWT GPM INDOOR FAN COOLING 10 CFM MOTOR (HP) ESP (IN) NOMINAL CAPACITY (TONS) TOTAL COOLING (BTUH) SENSIBLE COOLING (BTU ( BASIS OF DESIGN FC -2J1 SERVER ROOM CHILLED WATER NO 70.0/63.0 56.0/55.3 45.0 56.0 6.70 1570 (2) 1/3 .5 3 35,220 24,100 JOHNSON CONTROLS FNP16 02 10 PROVIDE CONDENSATE PUMP LITTLE GIANT PUMP MODEL VCL-24ULS ON CONDENSATE DRAIN. ROUTE TO CONDENSATE DRAIN ON AH2J2A. SIEMENS TO PROVIDE FIELD INSTALLED BACNET PTEC UNIT CONDITIONER CONTROLLER FOR APPLICATION 6645 PRO ESSIO AL ST '+ P & SIGNATURE E I - T REVISION AREAS ONLY AS INDICATED ISSUED FOR CONSTRUCTION 05.12.17 REVIEWED FOR VODE COMPLIANCE APPROVED Fit MAY 2 3 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 19201 PERMIT CENTER • FSI consulting engineers Seattle, Washington Solutions 84 Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE — RECORD DRAWING SR GS KR 06.15.93 A F-22 WORK ROOM W1208311 DLR GROUP RJV 06.29.12 — RECORD DRAWING B SECURE SPACE W1208311 DLR GROUP 33090-12 FSi RJV 10.19.12 05.12.17 0:EaBONG- 05.12.17 SlCIND ACCEPTABILITY This DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. BUN CHECKED M. FEINSTEIN DATE SUBTITLE SCHEDULES CURRENT REVISION SYMBOL 33090-12 3 DATE 05.12.17 ENGINEER M. FEINSTEIN CHECKED D. KLOTZ APPROVED R. RAMSEY APPROVED P. WOLD TITLE 3.14.91 MECHANICAL MASTER SECURE SPACE BUILDING 09-101 SHEET M1D JOB NO. COMP NO. DEV. CENTER, WA DWG NO. 09-101—M1 D 10/16/2012 3:45:19 PM aJ 24x24 RETURN GRILLE (TYP) 12x12 RETURN GRILLE WITH 2” OF ACOUSTICAL INSULATION INSIDE OF DUCTWORK 12x12 WITH SOUND LINE TEMP. SENSOR TO ALARM PANEL!_ DWG 109-101-2241 E-1 & 2002 EXITWY -66 96x48 ACOUSTICAL BOOT -« 1 375 CFM (TYP 12) 12” FLEX (TYP 12) 750 C (2 TYP 20" X 18" DUCT (TYP 4 38/24 20x20 120 120 BOOT TEES 2M12 M635 26" X 14" X 48" LONG TRANSITION 1,111 JIB 1411111k /I dmigirm..ipmEEITAEEEI I30 0 OSA D rfall:ak P STORAGE OFFICE TROL _NEAR 221" WITH 1" PERFORATED S (6 CUN LINT EE1 M 96x48 ACOUSTICAL BOOT 20" X 14" X L" LON TRANSITION (T P 3) - /2.5 " DUCT B.O. 18'- 7" AS 350 CFM CD (4 TYP) 8A 0 HALLWAY® 23M2 30/22 240 CFM 5TYP @ B.O.D. EL. 7'- 3" ASF 20" X 18" DUCT B.O.D. ELEV. OF 17- 4 ASF (TYP 4) N�.' d- / - _ 1 / 16 16 120 100 TEMP. SENSOR TO ALARM PANEL SEE DWG #109-1 01 —2 241 E-1 & 2002 E-66 BOD EL @ 10'-0" '--12/12 300 CFM CD 4 TYP 12/12 x 120(4 TYP) 30/22 12" TITUS ESV 3000 DROP CT UNDER CATWAL 2M12 2M462 OA INTAKE TO 1ST FLOOR WI FIRE DAMPER 2ND FLOOR S 1 300 CFM 111 !.,„AV/X/,!/,,,/,,,,,,,/„/,,,,,,, sac/aiAK //// /1// /// 41, IJ /,,///////: T //)W 7/ // //// // /////// // ///// / /r'/ / / / /// f - _ - -_ ._,...._.... __ _ ._._ --] ; Ir 40/24 fi Flip F---ILI_ 100(4 TYP) ti • SECO\D = LOCH PLA\ SCALE: 1/8' =1'-0" L PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED 1 8' 4' 0 4' 8' 16' SCALE: 1 /8"=1'-0" 11(7 LEGE\ D: 0 STATIC PRESSURE SENSOR QT--� T—STAT LOCATED IN RETURN GRILLE 11 • DIFFUSER BLANK—OFF SECTION 24/24 EGGCRATE RETURN GRILLE VAV TERMINAL UNIT CLR = CENTER LINE RADIUS LATERAL OR SEISMIC BRACING GE\EAL \OYES: 1. SIZE OF FLEX RUNOUT IS SAME AS DIFFUSER NECK UNLESS INDICATED OTHERWISE. 2. INSTALL EARTHQUAKE TABS (2 PER DIFFUSER) ON ALL DIFFUSERS AND ATTACH WITH 12 GA WIRE TO UNISTRUT GRID. 3. SEAL ALL PIPE PENETRATIONS THROUGH SECURE WALL. PROVIDE SECURE BARS IN WALL/CEILING PENETRATION PER DETAIL 2/M635. PROVIDE ACCESS DOOR WITH LOCK TO VERIFY SECURE BARS ARE INSTALLED. 6 > PROVIDE FIRE/SMOKE DAMPER IN CEILING TO MAINTAIN FIRE RATING OF THE CEILING. 7. ALL VAV BOX CONTROLS ARE TO BE PROVIDED BY SIEMENS AND CONNECTED TO THE EXISTING DDC. SIEMENS TO PROVIDE GRAPHICS AND AS—BUILT DRAWINGS. CO\STRUCTION \OTES CONNECT 14x14 DUCT TO EXISTING DUCT. PROVIDE ACOUSTICAL BOOT ON EXISTING FIRE DAMPER LINE DUCTWORK WITH 2" OF ACOUSTICAL INSULATION. CONNECT 26" ROUND DUCT WITH 2" ACOUSTICAL LINER TO EXISTING 26" DUCT. TEMPERATURE SENSOR TO BE PROVIDED BY SIEMENS. RECEIVED CITY OF TUKWILA MAY 192017 PERMIT CENTER ISSUED FOR CONSTRUCTION 05.12.17 KEY P SCALE: NONE REVIEWED FOR CODE COMPLIANCE :., APPROVED ,7 3 1 MAY 232017 City of Tukwila BUILDING DIVISION • FSi consulting engineers Seattle, Washington Solutions & Service SYM REVISION BY APPROVED DATE SYM REVISION A AIRFRAME CONF. ROOM B PROVIDE AIR TO AIRFRAME CORRIDOR J#147024-02 J#147024-07 C E F F-22 CLASSROOM RE -ARRANGE DIFFUSER PROVIDE TWO OFFICES F-22 J#771031-02 J#1 10136-00 J#546383-00 KGP DMV SPR DMV G F22 TRAINING ROOM RELOCATION C. HARRAH RWS/EJC RWS 8.4.97 8.4.97 8.7.04 H J CAFETERIA - RECORD DRAWING J#160530-04 12254733 SECURE SPACE 33090-12 BY M.WONG HGI FSi APPROVED DATE RWS SEL 10.25.06 10.31.13 05.12.17 Q� BE/NGS ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. BUN DATE CHECKED S. ROSSE ENGINEER A. KIWP CHECKED G. SMITH SUBTITLE HVAC DUCTING CURRENT REVISION SYMBOL 33090-12 J DATE 05.12.17 APPROVED K. RAMSEY APPROVED TITLE MECHANICAL MASTER SECURE SPACE BUILDING 9-101.2 COL. J—N/1-6 DEV. CENTER, WA SHEET 2M12 JOB NO. COMP NO. DWG NO. 9-101.2-2M 12 *** DO NOT TYPE HERE *** T f% Flip 21111 ®J I2ll14 imEl /2M12 zM1 121117 pp I2U19I 21(20 m I i i I 121(2211 I 2112 Enrui EMI 2M26 M r I 21(22ML 9I 12M3o I ® 121132 I ima li - - N- • FSi consulting engineers Seattle, Washington Solutions & Service SYM REVISION BY APPROVED DATE SYM REVISION A AIRFRAME CONF. ROOM B PROVIDE AIR TO AIRFRAME CORRIDOR J#147024-02 J#147024-07 C E F F-22 CLASSROOM RE -ARRANGE DIFFUSER PROVIDE TWO OFFICES F-22 J#771031-02 J#1 10136-00 J#546383-00 KGP DMV SPR DMV G F22 TRAINING ROOM RELOCATION C. HARRAH RWS/EJC RWS 8.4.97 8.4.97 8.7.04 H J CAFETERIA - RECORD DRAWING J#160530-04 12254733 SECURE SPACE 33090-12 BY M.WONG HGI FSi APPROVED DATE RWS SEL 10.25.06 10.31.13 05.12.17 Q� BE/NGS ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. BUN DATE CHECKED S. ROSSE ENGINEER A. KIWP CHECKED G. SMITH SUBTITLE HVAC DUCTING CURRENT REVISION SYMBOL 33090-12 J DATE 05.12.17 APPROVED K. RAMSEY APPROVED TITLE MECHANICAL MASTER SECURE SPACE BUILDING 9-101.2 COL. J—N/1-6 DEV. CENTER, WA SHEET 2M12 JOB NO. COMP NO. DWG NO. 9-101.2-2M 12 *** DO NOT TYPE HERE *** 12/24 RETURN GRILLE (TYP) TEMP . SENSOR TO ALARM PANEL S1 € ( DWG #109-101-2241 E-1 & 2002 -66 375 CFM (TYP 12) 12" FLEX (TYP 12) 2M12 M530 350 CFM 38/24 20" X 18" DUCT (TYP 4) 26" X 14" X 48" LONG TRANSITION 24 R R GRILLE DOWN AT 4 350 CFM (3 TYP) FLEX CONN 220 1] Will AH2�` I 2A J sir MID. _ �+/��AM Tikau-m e-2 W' iMMSETMIE.IMWAI 30" 14" X 90' 50 OSA DUCT TIED TO AH 5" TO 30"0 TRANS. 5" CLR ELL VIA A A 30" 26" DIA DUCT W/2" HICK DUCT L ER, B.O.D. L. 20 ASF 20" X 14" X 4" LON TRANSITION (T P 3) -' -o m 0 NO 12"0 NECK 80D CFM, 247z4 DIFFUSER Pa (TYP.) TO CO TROL NEAR COL N/2.5 0 BOOT ,TEE 26" DUCT : '- 2" AS' 26" DUCT B.O.D. r, 18'- 7" ASF INSTALL A 19"SQ. T 26"x90'20" CLR E RAISE DUCT TO B.0 WILL BE LINED W/2 26"x i RANS ON AHU. THIS WI ELEV. OF 20' A DUCT LINER L F. BOT CFM 2 TYP) 30/22 240 CFM (5TYP) 20" B.O.D. EL. OF 1r'— 3" ASF 20" X 18" DUCT B.O.D. ELEV. OF 17'- 4" ASF (TYP 4) N // /// / '- 1 / TEMP. SENSOR TO ALARM PANEL SEE DWG #109-101-2241 E-1 & 2002 E-66 120 100 BOD EL © 10'-0" 16/16 V2 375 CFM (4 TYP) 300 CFM CD (4 NP) 10 100(4 TYP) 30/22 375 CFM `-12' TITUS =SY 3000 VAX `v C DROP DJCT UNDER CATWALK - i OA INTAKE TO 1ST FLOOR WI* -I FIRE DAMPER JET 2ND FLOOR SLAB 00 CFM / CD 300 CFM 4 TYP 7 71 4;0 //J////////////////s//////!//////////J!////i////////////f/////t////1////////// -L i i//J'/////'''////////////////////////////////////////////////l!//////////%?////////////f//////////LSI. 40/24 f 1211a 1 12111` 21412 12)413 I 335 CFM (2 1`(P) 100(4 TYP) 12/12 16 16 ■I� 0 12/12 100(4 TYP) r x SECOND LOOR PLAN SCALE: 1/8' =1'-0" PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED 1 8' 4' 0 4' SCALE: 1 /8"=1'-0" 8' 16' LEGE\D: 0 STATIC PRESSURE SENSOR T—STAT LOCATED IN RETURN GRILLE GE\ DIFFUSER BLANK—OFF SECTION 24/24 EGGCRATE RETURN GRILLE VAV TERMINAL UNIT CLR =CENTER LINE RADIUS LATERAL OR SEISMIC BRACING ERAL \ OTES : SIZE OF FLEX RUNOUT IS SAME AS DIFFUSER NECK UNLESS INDICATED OTHERWISE. INSTALL EARTHQUAKE TABS (2 PER DIFFUSER) ON ALL DIFFUSERS AND ATTACH WITH 12 GA WIRE TO UNISTRUT GRID. REMOVE EXISTING TRANSFER DUCT AND PATCH WALL. RECEIVED CITY OF TUKWILA MAY 192011 PERMIT CENTER REMOVAL KEY P REVIEWED FOR CODE COMPLIANCE APPROVED MAY 232017 City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION 05.12.17 SCALE: NONE Vai FSi consulting engineers Seattle, Washington Solutions 8c Service SYM REVISION A B C AIRFRAME CONF. ROOM PROVIDE AIR TO AIRFRAME CORRIDOR F-22 CLASSROOM J#147024-02 J#147024-07 J#771031-02 BY KGP DMV SPR APPROVED DATE SYM G REVISION H 8.4.97 J F22 TRAINING ROOM RELOCATION CAFETERIA - RECORD DRAWING SECURE SPACE J#160530-04 12254733 33090-12 BY M.WONG HGI FSi APPROVED DATE RWS SEL 10.25.06 10.31.13 05.12.17 E RE -ARRANGE DIFFUSER J#110136-00 DMV RWS/EJC 8.4.97 F PROVIDE TWO OFFICES F-22 J#546383-00 C. HARRAH RWS 8.7.04 BOE/NG® � 05.1217 SAM ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. BUN DATE CHECKED S. ROSSE ENGINEER A. KILLIP SUBTITLE HVAC DUCTING CURRENT REVISION SYMBOL 33090-12 J DATE 05.12.17 CHECKED G. SMITH APPROVED K. RAMSEY APPROVED TITLE MECHANICAL MASTER SECURE SPACE BUILDING 9-101.2 COL. J—N/1-6 DEV. CENTER, WA SHEET 2M12R JOB NO. COMP NO. DWG NO. 9-101.2-2M 2R *** DO NOT TYPE HERE *** 1211a 1 12111` 21412 12)413 I I2M21I 211 1 1211.1 EliEl 12M201 21417 iI 12M2211 2123 F I21425I 2M26 m I II 1 1 [9] 1211291 I 2M30I © I2111321 Eal II N ISSUED FOR CONSTRUCTION 05.12.17 SCALE: NONE Vai FSi consulting engineers Seattle, Washington Solutions 8c Service SYM REVISION A B C AIRFRAME CONF. ROOM PROVIDE AIR TO AIRFRAME CORRIDOR F-22 CLASSROOM J#147024-02 J#147024-07 J#771031-02 BY KGP DMV SPR APPROVED DATE SYM G REVISION H 8.4.97 J F22 TRAINING ROOM RELOCATION CAFETERIA - RECORD DRAWING SECURE SPACE J#160530-04 12254733 33090-12 BY M.WONG HGI FSi APPROVED DATE RWS SEL 10.25.06 10.31.13 05.12.17 E RE -ARRANGE DIFFUSER J#110136-00 DMV RWS/EJC 8.4.97 F PROVIDE TWO OFFICES F-22 J#546383-00 C. HARRAH RWS 8.7.04 BOE/NG® � 05.1217 SAM ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. BUN DATE CHECKED S. ROSSE ENGINEER A. KILLIP SUBTITLE HVAC DUCTING CURRENT REVISION SYMBOL 33090-12 J DATE 05.12.17 CHECKED G. SMITH APPROVED K. RAMSEY APPROVED TITLE MECHANICAL MASTER SECURE SPACE BUILDING 9-101.2 COL. J—N/1-6 DEV. CENTER, WA SHEET 2M12R JOB NO. COMP NO. DWG NO. 9-101.2-2M 2R *** DO NOT TYPE HERE *** c\D HWS HWR HWS HWR HWS HWR HWS HWR EXITWAY HWS HWR FAN/COIL 2Y"HWS&R MICROPROCES OR CONTROLLER N THE WALL FOR A/ UNIT - V2 --CHWS HWS 1/2" HWR HWE HWR 22M2 HWS HWR 1 FOR COIL AND CONDENSATE CONNECTION S DETAIL 5 X62 M5 2" ChWS & TOP EL 18 FROM 6" AS 2 1/2 CHW 2 1/2 CHWR UP J =(21M2) 22M2 23M2 IL— DRAIN 21M3 7'-0"x10'-0" BOP EL 61'-4" 1 (/ FOR COIL AND CONDENSATE CONNECTION SEE DETAIL %5 HWR HWS HWR HWS T 6'-0"x6'-0" HW 24M1 HWS BOP EL 61'-0" HWR--411 HWS® HWR HWS - 2M621 M510 /AH2 �J4A, U 1 1/4" (4) 1 1/4" HWS/R UP TO AHRN5 I (ON ROOF) 2 1/2" CHWS & R FROM ROOF HWR HWS 1 1 /2" HWR 1 1/2" HWS HJ -o 2 1/2" CHWS & R FROM ROOF (CAPPED) II UP TO AHRM5 II (ON ROOF) HWR HWS HWR HWS ////"///l//l//l////r///l//rl/al!/l///////l//////r".J///l/"////a! f/- /./a/ N Moir/sariilii/// //a /// 9' ///iaiirl/ /// /// ,/ // U 0 10 1" HWS/R UP II TO AHRM6 I (ON ROOF) it r LL- _PAROF$SSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED C 1 1/2" HWR 1 1/2" HWS SECO\D FLOOR PLAN .9C,L-E; 1/8'=1'-0" 8' 4' 0 4' 8' SCALE: 1/8"=1'-0" 16' LEGE\ D STM STEAM PIPING C STEAM CONDENSATE PIPING HWS HEATING WATER SUPPLY HWR HEATING WATER RETURN CHWS CHWR CHILLED WATER SUPPLY CHILLED WATER RETURN X ANCHOR I'J 154 GATE VALVE CHECK VALVE BALL VALVE GLOBE VALVE BALANCING VALVE 2 WAY BRACE, FOR DETAILS SEE ><( 4 WAY BRACE, FOR DETAILS SEE GE\ RAL \ OTES 1. FOR CONTINUATION OF HWS/R PIPING UP, SEE DRAWINGS RFM12 AND RFM13. DEFERENCE DRAWINGS CO \STUCTIO\ NOTES CONNECT 1" CHWS & 1" CHWR TO EXISTING CHWS & CHWR. PRIOR TO STARTING WORK VERIFY EXISTING POINT OF CONNECTION. D RECEIVED CITY OF TUKWILA MAY 19 2017 PERMIT CENTER KEY PLAN SCALE: NONE ISSUED FOR CONSTRUCTION 05.12.17 O O 2M60 2M66 2M61 2M67 Oe O 2M68 2M63 2M69 REVIEWED FOR BODE COMPLIANCE APPROVED ft • MAY 2 3 2017 City of Tukwila BUILDING DIVISION 2M64 2M65 2M70 2M71 2M72 2M73 2M74 2M75 2M76 2M77 2M78 2M81 2M82 2M83 FSi consulting engineers Seattle, Washington SYM A B C D REVISION AIR FRAME CONF. ROOM INSTALL SPOT COOLER CAFETERIA - RECORD DRAWING SECURE SPACE J#147024-02 J#575568-00 12254733 33090-12 BY KGP M.WONG HGI APPROVED DATE SYM REVISION BY APPROVED DATE RWS SEL 02.01.07 10.31.13 FSi 05.12.17 BOE/NG Cr'— 05.12.17 sRauo ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. BUN CHECKED L. SAWYER ENGINEER L. SAWYER CHECKED D. KLOTZ DATE APPROVED K. RAMSEY APPROVED 12.21.90 SUBTITLE HVAC PIPING - SECOND FLOOR PLAN TITLE MECHANICAL MASTER SECURE SPACE BUILDING 9-101.2 COL. J–N/1-6 DEV. CENTER, WA Solutions 8c Service CURRENT REVISION SYMBOL 33090-12 D DATE 05.12.17 SHEET 2M62 JOB NO. COMP NO. DWG NO. 9-101.2-2M 62 SYM A HEAD BELO HEAD LOWE SV906 ALARM VALVE ON FIRST FLOOR SV905 ALARM VALVE ON FIRST FLOOR 1" AIR BLEED TO SV905 INSPECTORS TEST 0 )1 EL Al B S J 0 /2" 0 • /1) ENLARGED PLAN 2M262 2M463 eof- 1 "DRAIN VALV IN DUCT CHA 4" 2 1/2" i r. CZ CN REVISION BY APPROVED DATE SYM REVISION TO BY APPROVED DATE B C D E AIR FRAME CONF. ROOM ADD SPRINKLER HEADS PROVIDE TWO OFFICE F-22 CAFETERIA - RECORD DRAWING SECURE SPACE J#147024 J#111136-00 J#546383-00 12254733 33090-12 KGP DMV C. HARRAH HGI FSi RWS SEL 10.17.01 8.13.04 10.31.13 05.12.17 PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED Qi BOE/NG° o� 05.,217 SIMM 8' 4' 0 4' 8' 16' .1111111_1 - SCALE: 1/8"=1'-0" ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. BUN DATE APPROVED BY DEPT. DATE CHECKED R. PIERCE ENGINEER R. PIERCE CHECKED D. KLOTZ SUBTITLE LEGE\ D: CEILING LEVEL PENDENT SPRINKLER HEAD AND UPRIGHT HEAD AT ROOF LEVEL • PENDENT SPRINKLER HEAD - 0- UPRIGHT SPRINKLER HEAD -4D-- UPRIGHT SPRINKLER HEAD BELOW AHU AND CATWALK. SPRINKLER RISER ALARM VALVE ON FIRST FLOOR ®— I©I SVXXX SECTIONAL VALVE NUMBER (FOR EXAMPLE: SV907) 2 WAY BRACE, FOR DETAILS SEE 2M262 M507 4 WAY BRACE, FOR DETAILS SEE 2M262 M507 SPRINKLER HEADS GRINNEL MODEL VIKING MODEL (NEW) TEMP ORIFICE SIZE UPRIGHT OR PENDENT "K" FACTOR CRY(ORIGINAL) SSU -1 O 2M267 165 1/2" U 5.5 79 SSP -1 0 2M273 165 1/2" P 5.5 0 M p 155 1/2" U 5.5 5 M 0 155 1/2" P 5.5 80 TOTAL NO. OF HEADS (PHASE 2—D ONLY) 164 GE\ERAL NOTES: 1. THIS AUTOCAD DRAWING IS DRAWN BASED ON DATA TAKEN FROM THE FOLLOWING HAND DRAFTED EXISTING DRAWINGS: A. DWG NO. 21, CONT. NO.26-FP-1313, LAST REV. DATE: 12-20-83 B. DWG NO. 22, CONT. NO.26-FP-1313, LAST REV. DATE: 4-28-83 C. DWG NO.109-101-4404-M9, REV. B, 6-10-85 D. DWG NO.109-101-4478-M 1, REV. B, 1-26-87 E. DWG NO.109-101-4478-M2, REV. A, 11-20-86 2. SPRINKLER SYSTEMS ON THIS DRAWING HAVE BEEN HYDRAULICALLY CALCULATED USING A DENSITY OF 0.20 GPM/SOFT AND A DESIGN AREA OF 1500 SOFT. A HOSE STREAM ALLOWANCE OF 500 GPM AT THE SOURCE HAS BEEN MADE. CO \STUCTION CTES REUSE EXISTING SPRINKLERS. ROUTE SPRINKLERS AROUND NEW WALLS AS REQUIRED TO MAINTAIN ORDINARY HAZARD GROUP II CLASSIFICATION. RECEIVED CITY OF TUKWILA MAY 19 2017 PERMIT CENTER ISSUED FOR CONSTRUCTION 05.12.17 FIRE PROTECTION PLAN VIEW REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 2017 City of Tukwila BUILDING DIVISION 00 Cz) / V T T T T 2M260 2M261 /2M262i 2M263 2M266 2M267 2M268 2M269 2M273 2M274 2M275 --H 2M279 2M280 2M281 KEY PLAN SCALE: NONE FSi co0 nsulting engineers Seattle, Washington Solutions & Service CURRENT REVISION SYMBOL 33090-12 E DATE 05.12.17 APPROVED K. RAMSEY APPROVED P. WOLD 12.21.90 TITLE SECURE SPACE BUILDING 9-101.2 MECHANICAL MASTER COL. JA—N/1-6 DEV. CENTER, WA SHEET 2M262 JOB NO. COMP NO. DWG NO. 9-101.2-2M262 DETNU3: 08/09/04 08:42 SEQUE\CE OF OPEATIO\: FAN COIL CONTROL START/STOP THE DDC SHALL ENABLE THE FAN IN THE FAN COIL TO START AT LOW AIRFLOW. THE FAN COIL SHALL RUN CONTINUOUSLY WHEN COOLING IS REQUIRED. TEMPERATURE CONTROL THE SPACE TEMPERATURE SENSOR SHALL RESET THE BOX DISCHARGE TEMPERATURE TO MAINTAIN THE SPACE SETPOINT. AS THE CALL FOR COOLING INCREASES, THE DDC SHALL OPEN THE FAN COIL CHILLED WATER CONTROL VALVE. AS THE FAN COIL CONTROL VALVE REACHES ITS FULL OPENED POSITION AND THERE IS A CONTINUES CALL FOR COOLING THE DDC SHALL COMMENT THE FAN TO INCREASE SPEED TO MEDIUM/HIGH AIRFLOW TO MAINTAIN SPACE SETPOINT TEMPERATURE. AS THE CALL FOR COOLING DROPS, THE DDC SHALL REDUCE THE SPEED OF THE FAN TO MEDIUM/LOW AIRFLOW. ONCE THE FAN IS AT LOW AIRFLOW AND THERE IS A CONTINUED DROP IN CALL FOR COOLING, THE DDC SHALL MODULATE THE FAN COIL CHILLED WATER COIL CONTROL VALVE TO MAINTAIN THE SPACE SETPOINT. POI\TS LIST: BUILDING CONTROL SYSTEM POINT SUMMARY SYSTEM NAME: FAN COIL — FC -2J1 DESCRIPTION: ANALOG INPUTS ANALOG OUTPUTS DIGITAL INPUTS DIGITAL OUTPUTS ALARMS REMARKS TYPICAL OF FC -2J1 SPACE TEMPERATURE 1 1 ALARM IF SPACE TEMP IS 10DEG ABOVE SETPOINT SPACE SETPOINT 1 FAN START/STOP 1 FAN PROOF 1 1 CURRENT SENSING RELAY FAN SPEED (LOW/MEDIUM/HIGH) 1 AIRFLOW (LOW/MEDIUM/HIGH) 1 CHW CONTROL VALVE 1 ISSUED FOR CONSTRUCTION 05.12.17 REVIEWED FOR CODE COMPLIANCE , APPROVED MAY 232017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 19 2011 PERMIT CENTER 6 • FSi consulting engineers 'Seattle, Washington Solutions & Service SYM REVISION ORIG SECURE SPACE 33090-12 BY FSi APPROVED DATE 05.12.17 SYM REVISION BY APPROVED DATE el,BOE/NGm - 05.12.17 srcxm ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. PENROD DATE CHECKED SUBTITLE SEQUENCE OF OPERATIONS & I/O POINTS CURRENT REVISION SYMBOL 33090-12 ORI G DATE 05.12.17 ENGINEER CHECKED APPROVED APPROVED TRLE SECURE SPACE MECHANICAL MASTER BUILDING 9-101.2 COL. X—X/X—X DEV. CENTER, WA SHEET M323 JOB NO. COMP NO. DWG NO. 09-101—M323 10106A: 3/7/2013 NOTE: X = DUCTWORK PRESSURE IN H20, CONTRACT OR TO MEASURE & VERIFY IN THE FIELD. 2", TYP c U V) PRESSURE & TEMP TEST PORT, TYP MANUAL VENT VERIFY COIL INLET AND OUTLET CONN. LOCATION PRIOR TO PIPING FABRICATION AND INSTALLATION. CONNECT INLET AND OUTLET PER MANUFACTURER'S INSTRUCTIONS. 1" COOLING COIL 3/4" TO DRAIN CAPPED TEE, TYPJ 2 -WAY MODULATING CONTROL VALVE (P.I.C.V) MANUAL DRAIN WITH HOSE -END CONNECTION AND CAP, TYP. DRAIN PAN '-CONDENSATE PUMP FC -1 COOLING COIL WITH 2 -WAY VALVE DETAIL SCALE: NTS (Th\ 2M621M635 1/8/1/2 - 2 1/8 1/2 - 2 L2"X2"X1/4" 1/4" LAG SCREW SECURE AREA • o• .o e .• o O A. O . .••• 000- . DUCT OPEN AREA NOTE: INSTALL INSPECTION PORT IN DUCTING, IN AN ACCESSIBLE LOCATION ON SECURE SIDE OF ROOM. FABRICATE FRAME FROM L 2X2X 1/4 1‘2"0 CROSS BARS 6 O.C. EACH WAY WELD © BAR INTERSECTIONS — FABRICATE FRAME IN (2) PIECES. BOLT PIECES TOGETHER IN FIELD - TACK WELD NUT TO ROD • ASSESS DOOR ON SECURE SIDE OF DUCT RUSKIN ADH12 - RECTANGULAR DUCT, RUSKIN ARDD - ROUND DUCT. 1/4"0 LAG SCREW EXTERIOR FRAME TO WALL ON SECURED SIDE (APROX. 12" O.C. OR 2 EA. LEG MINIMUM) EXISTING DUCT 1/2" NUT a a r--1/2"0 X 1 1/2" BOLT 1/21'0 NUT TACK WELD NUT TO BOLT (TYP.) . EXISTING DUCT UNSECURED SIDE OF WALL NOTE: SIMILAR CONSTRUCTION SHALL BE USED FOR ROUND & OVAL DUCTS ROUND AND RECTANGULAR DUCT SECURITY GRILLE DETAIL (2 2M12 M635 SCALE: NTS 96x48 OPENING MIN. 24" 2" ACOUSTICAL LINING ti O PROVIDE ACCESS DOOR ON SECURE SIDE SECURE BAR SECURED SIDE OF WALL SECTION VIEW ACOUSTICAL BOOT DETAIL EXISTING FIRE DAMPER 96x48 OPENING UNSECURED SIDE OF WALL 3 SCALE: NTS 2M:1_21.„1635 ISSUED FOR CONSTRUCTION 05.12.17 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 232017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 192017 PERMIT CENTER 0 FSI consulting engineers Sea.ttle, Washington Solutions •& Service SYM REVISION ORIG SECURE SPACE 33090-12 BY FSi APPROVED DATE SYM REVISION BY APPROVED DATE 05.12.17 m Q� M&ff/NG o-- 05.12.17 OMB ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. PENROD CHECKED DATE SUBTITLE DETAILS CURRENT REVISION 33090-12 SYMBOLORIG DATE 05.12.17 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER SECURE SPACE BUILDING 9-101.2 COL. X—X/X—X DEV. CENTER, WA SHEET M635 JOB NO. COMP NO. DWG NO. 09-101—M6 35 10106A: 3/7/2013