Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M17-0073 - WOODSPRING SUITES - A/C UNITS
WOODSPRING SUITES 15637 WEST VALLEY HWY MI 7-0073 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0005800002 15637 WEST VALLEY HWY Project Name: WOODSPRING SUITES MECHANICAL PERMIT Permit Number: M17-0073 Issue Date: 10/30/2017 Permit Expires On: 4/28/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: NELSEN FAMILY TRUST 10510 NORTHUP WY #300 C/O VWC, KIRKLAND, KS, 98033 LINDSEY KNOX 6700 ANTIOCH PLAZA - SUITE 300 , MERRIAM, KS, 66204 WASATCH DC BUILDERS NW LLC 10620 NE 9TH PL , BELLEVUE, WA, 98004 WASATDB846OR Phone: (913) 236-3404 Phone: (425) 974-7071 Expiration Date: 9/19/2018 DESCRIPTION OF WORK: EXTENDED ASTAY HOTEL THAT IS CONSIDERED A MULTI -FAMILY DWELLING. A/C IN EACH UNIT. ALL EQUIPMENT PER SHEET M1 TO BE INSTALLED IN WOODSPRING SUITES TUKWILA Valuation of Work: $301,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $3,618.92 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: international Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 )�y. Permit Center Authorized Signature: \F' Date: t O I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development p- . , •`, e to the conditions attached to this permit. Signature: t V/1 Print Name: Date: t /3'1//7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0609 0705 0701 MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKW.. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. tit (71 �i -I; Project No. Date Application Accepted: s — 2S -1 7 Date Application Expires: ( )� —1 7 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 15643 W. Valley Hwy., Tukwila, WA 98188 Suite Number: Floor: Tenant Name: WoodSpring Suites Hotel PROPERTY OWNER Name: Lindsey Knox Name: Tukwila Hotel Holdings, LLC. City: Merriam State: KS Zip: 66204 Address: 10620 NE 9th Place Email: lindsey.knox@brrarch.com City: Bellevue State: WA Zip: 98004 CONTACT PERSON — person receiving all project communication Name: Lindsey Knox Address: 6700 Antioch Plaza, Suite 300 City: Merriam State: KS Zip: 66204 Phone: (913) 236-3404 Fax: Email: lindsey.knox@brrarch.com New Tenant: ® Yes El.. No MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 11 000 Describe the scope of work in detail: Extended stay hotel that is considered a multi -family dwelling. AAL /N e (AA - .4 c\„,J 1' \ \ L i a� IAUse:vr w Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric ® Gas Other: H:\Applications\Forms-Applications On Line \2016 Applications \Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type ' 'Qty Furnace <100k btu 131 Furnace >100k btu 18 Floor furnace 135 Suspended/wall/floor mounted heater 5 Appliance vent 3 Repair or addition to heat/refrig/cooling system 131 Air handling unit 65 dB(A) <10,000 cfm 3 Unit Type Qty Air handling unit 131 >10,000 cfin 18 Evaporator cooler 135 Ventilation fan connected to single duct 129 (Exhaust Fans) Commercial Ventilation system 131 Hood and duct 65 dB(A) Incinerator — domestic 60 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper 131 Diffuser 18 Thermostat 135 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment (PTACs) 131 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3 3-15 hp/500,000 btu Industrial 15-30 hp/1,000,000 btu 55 dB(A) 30-50 hp/1,750,000 btu 57 dB(A) 50+ hp/1,750,000 btu Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O�N�A THO IZED AGENT: Signature: Date: 47- 2C-- 17 Print Name: i 6 V tc1 L VI �O) Day Telephone: t25. /0j.i5Z3 `p Mailing Address: /0‘, 1( Zb E Tit ?1,1-&---Re/J,, L.e v4. C( oof City State Zip H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,922.97 M17-0073 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $2,922.97 MECHANICAL $2,783.78 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $2,750.63 TECHNOLOGY FEE $139.19 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12683 R000.322.900.04.00 0.00 $139.19 $2,922.97 Date Paid: Monday, October 30, 2017 Paid By: MM COMFORT SYSTEMS Pay Method: CHECK 344706 Printed: Monday, October 30, 2017 1:22 PM 1 of 1 CiSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY PAID $4,546.68 EL17-0398 . Address: 15637 WEST VALLEY HWY Apn: 0005800002 $1,672.36 ELECTRICAL $1,672.36 PLAN CHECK FEE 1 R000.345.832.00.00 I 0.00 I $1,672.36 M17-0073 Address: 15637 WEST VALLEY HWY Apn; 0005800002 $695.95 MECHANICAL $695.95 PLAN CHECK FEE 1 R000.322.102.00.00 I 0.00 $695.95 PG17-0072 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $2,178.37 GAS $24.86 PLAN CHECK FEE 1 R000.322.103.00.00 I 0.00 I $24.86 PLUMBING $2,153.51 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R11582 R000.322.103.00.00 0.00 $2,153.51 $4,546.68 Date Paid: Friday, May 26, 2017 Paid By: TUKWILA HOTEL HOLDINGS Pay Method: CHECK 1001 Printed: Friday, May 26, 2017 11:30 AM 1 of 1 CSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: G✓ J) SPR) * S Ut:TrS Type of Inspection:. Address:�� 7563 7 e1'. y!/gLLLVVY Date Called: Special Instructions: v6,//N j >oft Date Wanted: 1742-i7 a.m. p.m. Requester: RICK Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: p% f —12ol7 4CVZ1.. '� /h�cM4HIO9t_ R /AI Inspector: Date: �p I2(i`(7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit �'I d.Z oto? 3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION -g1/4P 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: l D.SPAii/& S-'O(7Z5 Type of Inspection: 6 /4/9-1- rA 1-->✓9///cc Addres is '7 AAv; y f Date Called: Special Instructions: Date Wanted: 5-- /8 a.m. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: c�44- f'1710-1- ev\acttithcfr inspector: Date: a REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit /1117 -6(513 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: / 37 G.%I1ituxY livr Date Called: Special Instructions: Date Wanted: 5 -2. -/8 i a.m. ,p.m. Requester: Phone No: Approved per applicable codes. L Corrections required prior to approval. COMMENTS: — Inspector: Date: 5-t-16 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION rim -0013 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Prod ct: (L� W (Mac f� U \ 1C� Type of Inspection: + L I � .,in i cei F1NA/- .1 Address: Address: 1 v 1537 \ss4 VV.ktn Date Called: Special Instructions: i Date Wanted: 2 Ca.m} Requester: Phone No: Approved per applicable codes. L� Corrections required prior to approval. COMMENTS: . t 142 ax„ e A1AL/ nco1 L �S+ LL Akx..4 ,a 4.)0Y( rs k CAL 'cz) ,$+oc.[< Inspector Date: q - Zd _Zo J' REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 17—N73 INS N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 rod ct: dol 'rt% S , cI� r leS T pe of Inspection: �eE l�►04-,1�.L- r r � Address. Oes-f V 14/Date Date Called: Spei lal Instructions: Wanted: Z4_,z—tel a.m. gf pm Requester: Phone No: ❑ Approved per applicable codes. COMMENTS: Corrections required prior to approval. *tc__ kityi - 4 et-prewn lAJ refAUS .0t/ti p 2 r1S e TAis t om] m T' — "0/".2-42;s Inspector: Date: qv2-20 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M 11-0073 PrProject:Type WODC P s t, of Inspection: � M Qp ply Address: � J 156,37 tdO 4U7 iftwil Date Called: 3-5-2oe Special Instructions: Date Wanted: 7 /� zorl = P.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: • Mme, ik r-<-7ar--rij d t ,r/c. cg:k" 2v" �s .p.vvedi r -6Y cover -fh�ss ext- arid(6.u4sf/ Mi* r) te,,4. td n.s v Inspector* Date: 3 ,Z. mcg. REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Ali -6073 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: - %fla, /VeVC S> 5' Type of Inspection: RDU(. --/N M i . Address:; ''� /,� 7�r Ly/i"f Date Called: ,' Special Instructions: isVii4 -2 Date Wanted: / / �W �3 -s3./C.� p.m. Requester: Phone No: .200- 9-35 75 - Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 1..401eL 1 `2 r 3 rWick c_ -raj( Inspector: Date: 3 'l8 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 10/16/2017 City of Tukwila Department of Community Development LINDSEY KNOX 6700 ANTIOCH PLAZA - SUITE 300 MERRIAM, KS 66204 RE: Permit Application No. M17-0073 WOODSPRING SUITES 15637 WST VALLEY HWY Dear LINDSEY KNOX, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 5/25/2017, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 11/25/2017. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, ac elle Ripley Permit Technicia File No: M17-0073 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 brr Change Narrative Project Name: WoodSpring Suites Project Description: New Construction Project Number: 31000057 ARCHITECTURAL SHEET 151.1- BUILDING CODE AND LIFE SAFETY PLANS. DETAIL 1— FIRST FLOOR LIFE SAFETY PLAN 1. Revised wall of Elevator. Machine Room. 2. Addition of 2 -hour rated wall. SHEET A1.1 — FIRST FLOOR PLAN DETAIL 1- FIRST FLOOR PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. SHEET A1.6 — FIRST FLOOR RCP. DETAIL 1— FIRST FLOOR RCP 1. Revised wall of Elevator Machine Room. SHEET A4.1 — ENLARGED PUBLIC PLANS DETAIL 1- FIRST FLOOR ENTRANCE PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. DETAIL 2 — FIRST FLOOR FURNITIRE PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. SHEET A4.2 — ENLARGED FINISH PLANS Project Location: Delta Number: Revision Date: DETAIL 1— FIRST FLOOR REFLECTED CEILING PLAN 1. Revised wall of Elevator. Machine Room. 2. Revised room name to Elevator Machine Room. DETAIL 2 — FIRST FLOOR FINISH PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room •oo Tukwila, WA 9 - CCD#5 09/08/2017 REVISION N04 RECEIVED CITY OF TUKWILA SEP 182017 PERMIT CENTER Mn�rh vwuw.brrarch.com 6700 Antioch Plaza, Suite 300. Merriam, KS 66204 Page 1 of 3 MAIN 913.262.9095 Kansas City - Bentonville - Phoenix - San Francisco - Philadelphia - Atlanta - Austin - Miami - Los Angetes - Chicago Page 2 of 3 SHEET A6.2 — ELEVATOR PLANS, SECTIONS & DETAILS DETAIL 1— TYPICAL ELEVATOR TOWER SECTION 1. Revised room name to Elevator Machine Room. DETAIL 3 — FIRST FLOOR ELEVATOR PLAN 1. Addition of finish dimensions. 2. Revised room name to Elevator Machine Room. DETAIL 5 — UPPER FLOOR ELEVATOR PLAN 1. Removed elevator control panel note. SHEET A7.1— PARTITIONS, FINSH SCHEDULE & DETAILS ROOM FINISH SCHEDULE 1. Revised room name to Elevator Machine Room. SHEET A8.1— DOOR SCHEDULE & DOOR DETAILS DOOR SCHEDULE 1. Revised room name to Elevator Machine Room. 2. Revised fire rating of Elevator Machine Room. MECHANICAL SHEET M-1— MECHANICAL NOTES, SCHEDULES, AND LEGENDS SCHEDULE — DUCTLESS SPLIT SYTSEM SCHEDULE 1. Added to plans SCHEDULE — EXHAUST FAN FAN SCHEDULE 1. Remove EF -5. SHEET M-2 — MECHANICAL FIRST FLOOR PLANS DETAIL 4 — MECHANICAL FIRST FLOOR PLAN 1. Update elevator machine room. 2. Add FCU -1 to elevator machine room. SHEET M-5 — MECHANICAL FOURTH FLOOR PLANS DETAIL 3 — MECHANICAL ROOF PLAN 1. Add CU -1. DETAIL 4 — ELEVATOR SHAFT RELIEF HOOD DETAIL 1. Revise control description. PLUMBING SHEET P-2 — PLUMBING WASTE AND VENT PLAN 1ST FLOOR DETAIL 1— FIRST FLOOR WASTE & VENT 1. Revised sump pump drain line and floor drain per elevator change. SHEET P-6 — PLUMBING WATER AND GAS PLAN 1ST FLOOR DETAIL 1— FIRST FLOOR WATER AND GAS PLAN 1. Added hose bib per owner directed RFI. SHEET P-10 — PLUMBING ENLARGED PLANS wvwv.brrarch.com 6700 Antioch Plaza, Suite 300. Merriam. KS 66204 MAIN 913.262.9095 Kansas City - Bentonville = Phoenix - San Francisco'- Philadelphia - Atlanta - Austin - Miami - Los Angeles - Chicago Page 3 of 3 DETAIL 1— SUMP PUMP DETAIL 1. Revised sump pump drain line and floor drain per elevator change. ELECTRICAL SHEET E-1 — ELECTRICAL RISER DIAGRAM PANELBOARD SCHEDULES 1. Revised per drawing updates. SHEET E-2 — ELECTRICAL PLANS — FIRST FLOOR PANELBOARD SCHEDULES 1. Revised per drawing updates. SHEET E-3 — ELECTRICAL PLANS — FIRST FLOOR DETAIL 1— FIRST FLOOR ELECTRICAL PLAN 1. Added callout for elevator control room. DETAIL 3 — ENLARGED LAUNDRY 1. Revised treadmill electrical circuit. DETAIL 4 — ENLARGED ELEVATOR 1. Added detail and keynotes. SHEET E-6 — ELECTRICAL PLANS — FOURTH FLOOR DETAIL 2 — ELEVATOR ELECTRICAL PLAN 1. Removed detail. DETAIL 3 — ELECTRICAL ROOF PLAN 1. Added CU -1. End of Revision/Addendum/Construction Change Directive By: BRR Architecture, Inc., Drew Truskey, Designer www.brrarch.com 6700 Antioch Plaza, Suite 300. Merriam, KS 66204 MAIN 913.262.9095 Kansas City - Bentonville - Phoenix - San Francisco - Philadelphia - Atlanta - Austin - Miami - Los Angeles - Chicago "TWIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0073 DATE: 09/21/17 PROJECT NAME: WOODSPRING SUITES SITE ADDRESS: 15643 W VALLEY HWY Original Plan Submittal X Revision # 1 before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Mk7 °IIZD Building Division Public Works W $ � 1 Fire Prevention Structural Planning Division ❑ Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 09/21/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 10/19/17 ❑ Approved with Conditions (corrections entered in Reviews) Notation: Denied (ie: Zoning Issues) irlot( 5.e71-/7 Scyf bad wire✓isPel REVIEWER'S INITIALS: DATE: Permit Center. Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY:. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0073 DATE: 05/25/17 PROJECT NAME: WOODSRING SUITES SITE ADDRESS: 15637 WEST VALLEY HWY :X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: %J AWG (�t Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/30/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/27/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: tPermit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 PROJECT NAME: \V SITE ADDRESS: 19# 41) n 5uv+t IJAl PERMIT NO: M11" --00Th ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS I ISSUED DATE STAFF INITIALS I COI Summary of Revision: feij ri'D 0,. Received by: , REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED • STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 09.18.17 Plan Check/Permit Number: MiQO1' 9 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # X❑ Revision # t-afterPermit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: WoodSpring Suites Project Address: 15643 W Valley Hwy Contact Person: Lindsey Knox Phone Number: 913.:236.3404 Summary of Revision: The overall change was switching elevator types. The owner switched from a electric traction elevator to a machine room hydraulic elevator. It included adding a machine room adjacent to the elevator. Sheet Number(s): 18 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on W:\Permit Center\Templates\Forms\Revision Submittal Form.doc Revised: August 2015 WASATCH DC BUILDERS NW LLC Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of )Labor & Industries Page 1 of 2 Search L&I A -L Index Help My I:&I Workplace Rights Trades & Licensing WASATCH DC BUILDERS NW LLC Owner or tradesperson Principals Nielson, Michael James, MANAGER West77 Partners LLC, MANAGER Doing business as WASATCH DC BUILDERS NW LLC WA UBI No. 603 591 156 10620 NE 9th PI BELLEVUE, WA 98004 425-974-7071 KING County Business type Limited Liability Company Governing persons MICHAEL NIELSON LLC WEST77 PARTNERS; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. WASATDB846OR Effective — expiration 09/19/2016— 09/19/2018 Bond ................ Western Surety Co Bond account no. 62697583 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 09/19/2016 09/15/2016 Expiration date Until Canceled Insurance . _ ......................... Ironshore Specialty Ins Co $1,000,000.00 Policy no. AGS0100701 Received by L&I Effective date 10/11/2017 10/12/2017 Expiration date 10/12/2018 Insurance history Savings No savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603591156&LIC=WASATDB8460R&SAW= 10/30/2017 WASATCH DC BUILDERS NWT ,LC Lawsuits against the bond or savings No lawsuits against the bond or savings y.....ounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ..........._..._...................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 523,517-01 ............................. Doing business as WEST77 CONSTRUCTION LLC Estimated workers reported Quarter 2 of Year 2017 "7 to 10 Workers" L&I account contact T2 / SUSAN BETTS (360)902-4828 - Email: BETT235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ......_..._................._........................ No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603591156&LIC=WASATDB8460R&SAW= 10/30/2017 9/7/2017 4:36:55 PM MECHANICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION ABBREVIATIONS REMARKS DIFFUSER RETURN AIR GRILLE RETURN OR DUCT UP SUPPLY DUCT UP SUPPLY DUCT DOWN RETURN OR EXHAUST DUCT DOWNillibt\ ROUND DUCT DOWN DUCT UP VANED ELBOW LOW PRESSURE DUCT 45° TAKEOFF FITTING MANUAL VOLUME DAMPER FIRE/SMOKE DAMPER FIRE DAMPER CAPACITY EQUIPMENT (SEE SCHEDULE) AFF AOVE FINISHED FLOOR BTU BRITISH THERMAL UNIT CFM CUBIC FEET PER MINUTE COMP COMPRESSOR COD CABLE OPERATED DAMPER DB DRY BULB DN DOWN DX DIRECT EXPANSION EA EACH EAT ENTERING AIR TEMPERATURE EFF EFFICIENCY ESP EXTERNAL STATIC PRESSURE ETC AND SO FORTH EX EXHAUST °F DEGREES FAHRENHEIT FLA FULL LOAD AMPS FPM FEET PER MINUTE FT FEET GPM GALLONS PER MINUTE GRS/LB GRAINS PER POUND HP HORSEPOWER HZ HERTZ IN INCHES MW KILOWATT MBH THOUSANDS OF BTU PER HOUR MIN MINIMUM NEG NEGATIVE NTS NOT TO SCALE OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OC ON CENTER PH PHASE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE SARH RUPATIVE HUMIDITY AIH SH SENSIBLE HEAT SP STATIC PRESSURE TEMP TEMPERATURE TYP TYPICAL UC UNDERCUT VOLT VOLTAGE W/O WITHOUT WB WET BULB WC WATER COLUMN WEIGHT MCA MOCP FCU -1 / CU -1 CARRIER / 12 MBH X -X " EQUIPMENT NUMBER INDICATES DETAIL, PLAN, SECTION, AND/OR DIAGRAM(APPLIES ONLY WHERE INDICATEDON DRAWINGS) 10 nuEXHAUST 15.0 1,2,3,4,5 INDICATES DRAWING ON WHICH DETAIL APPEARS IL -- 18x24 TYP -- INDICATES TYPICAL DETAIL (APPLIES TO ALL CONTRACT DRAWINGS) DRAWING ON N / V 1,3,4 T1 X INDICATES WHICH DETAIL APPEARS UNIT SHALL BE SECURELY MOUNTED ON EQUIPMENT CURB FLASHED TO ROOF. PIPING SHALL BE SIZED AND INSTALLED PER MANUFACTURERS RECOMMENDATIONS. UNITS SHALL BE OF THE SAME MANUFACTURER. _ MOUNTED TEMPERATURE CONTROLLER. OPTIONAL 115V CONDENSATE PUMP AND RECEPTOR FOR INDOOR UNIT. 1 / V ALUMINUM WHITE INDICATES SECTION NUMBER WALL RD X AROUND INDICATES ON WHICH DRAWING SECTION APPEARS INDICATES REVISION & NUMBER CONNECT NEW TO EXISTING SHEET NOTE NUMBER DIFUSER TYPE SIZESES CFM THERMOSTAT HUMIDISTAT WALL SWITCH DUCT MOUNTED SMOKE DETECTOR MOTORIZED DAMPER ACTUATOR DOOR UNDERCUT TITUS REMARKS: C #> S1 10"0 300 TO O OS SD MD UC HIGH FACTORY ROOF CURB MATCHING ROOF SLOPE FOR LEVEL INSTALLATION OF HOOD. BIRD SCREEN. 1. PROVIDE WITH 14" 2. PROVIDE WITH ALUMINUM a SINGLE WALL ------\----1------\----1FLEX 1,2,3 ELECTRICAL ROOM 265 0 8,900 9.8 9,000 2.9 le FD I DUCTLESS SPLIT SYSTEM SCHEDULE MARK MANUFACTURER INDOOR UNIT OUTDOOR UNIT SEER REMARKS MODEL CAPACITY WEIGHT MODEL WEIGHT MCA MOCP FCU -1 / CU -1 CARRIER 40MFC012---3 12 MBH 20 LBS 38MFC012---3 75 LBS 10 15 15.0 1,2,3,4,5 -- 3 -- 18x24 36x36 -- 1,2 COD 1,3,4 T1 TITUS REMARKS: UNIT SHALL BE SECURELY MOUNTED ON EQUIPMENT CURB FLASHED TO ROOF. PIPING SHALL BE SIZED AND INSTALLED PER MANUFACTURERS RECOMMENDATIONS. UNITS SHALL BE OF THE SAME MANUFACTURER. _ MOUNTED TEMPERATURE CONTROLLER. OPTIONAL 115V CONDENSATE PUMP AND RECEPTOR FOR INDOOR UNIT. 1. REMOTE CONDENSING 2. REFRIGERANT 3. AIR CONDITIONING 4. PROVIDE REMOTE 5. PROVIDE MANUFACTURER'S ROOF HOOD SCHEDULE MARK MANUFACTURER MODEL TYPE USE MATERIAL CFM S'P' (IN) HOOD VELOCITY (FPM) FREE AREA (SQ FT) THROAT VELOCITY (FPM) DIMENSIONS (IN) WEIGHT (LBS) REMARKS THROAT HOOD RH-1 COOK 1824 -GR LOW CONTOUR RELIEF ALUMINUM -- -- -- 3 -- 18x24 36x36 -- 1,2 COD 1,3,4 T1 TITUS 350 FL RETURN SURFACE ALUMINUM WHITE SINGLE WALL OBD 1,2,3 R1 TITUS REMARKS: TRANSFER HIGH FACTORY ROOF CURB MATCHING ROOF SLOPE FOR LEVEL INSTALLATION OF HOOD. BIRD SCREEN. 1. PROVIDE WITH 14" 2. PROVIDE WITH ALUMINUM GRILLE, REGISTER, AND DIFFUSER SCHEDULE MARK MANUFACTURER MODEL USE MOUNTING MATERIAL FINISH DEFLECTION / THROW LOCATION ACCESSORIES REMARKS S1 TITUS 272 FS SUPPLY SURFACE ALUMINUM WHITE DOUBLE WALL OBD 1,2,3 rr`Y;-.r,=y''-•-•7-...,-,-....r."'r S2 TITUS 250-M SUPPLY SURFACE ALUMINUM WHITE 4 -WAY CEILING COD 1,3,4 T1 TITUS 350 FL RETURN SURFACE ALUMINUM WHITE SINGLE WALL OBD 1,2,3 R1 TITUS 350 FL TRANSFER SURFACE ALUMINUM WHITE SINGLE WALL OBD 1,2,3 ELECTRICAL ROOM 265 0 8,900 9.8 9,000 2.9 208 1 14.0 2,900 EMARKS: 20 ON PLANS FOR NECK SIZE AND CFM. RECTANGULAR TO ROUND ADAPTERS AT ALL GRD CONNECTIONS. ALL INTERIOR DUCT SURFACES VISIBLE THROUGH FACE OF GRILLE/DIFFUSER BY MECHANICAL CONTRACTOR). CRD -1 WJ CEILING RADIATION DAMPER ASSEMBLY FOR WOOD JOIST CONSTRUCTION. 1. REFER TO CALLOUTS 2. PROVIDE REQUIRED 3. PAINT, FLAT BLACK, 4. PROVIDE WITH GREENHECK PACKAGED TERMINAL AIR CONDITIONER SCHEDULE MARK MANUFACTURER MODEL SERVES(CFM) AIRFLOW VENTILATION (CFM) COOLING CAPACITY (BTUH) EER NOMINAL HEATING (BTUH) ELECTRIC HEAT (KW) ELECTRICAL INFORMATION REMARKS 1, -Yews VOLTAGE PHASE AMPS WATTS MCA MOCP PTAC-1 AMANA PTC073G35RXXX** GUEST ROOMS 310 65 7,700 11.7 6,800 2.5 208 1 10.1 2,115 14.1 15 1,2,3,4,5,6,7 PTAC-2 AMANA PTC153G35RVXX** CORRIDORS 360 95 14,700 10.0 9,900 3.5 208 1 14.1 2,935 19.5 20 1,2,3,4,5,6,8,9 PTAC-3 AMANA PBE093G35** ELECTRICAL ROOM 265 0 8,900 9.8 9,000 2.9 208 1 14.0 2,900 19.4 20 1,2,3,4,9 RESTROOM 139 75 0.38 CENTRIFUGAL 900 2 DIRECT 36 120 1 SWITCH W/ LIGHTS 25 1,2,3,4,8 RUUD NOT USED UPFLOW GUEST LAUNDRY REMARKS: 1600 1. EQUIPMENT SELECTIONS BASED ON AMANA BRAND THRU-WALL CHASSIS UNITS WITH ELECTRIC COOLING & HEATING. FRONT COVER & FACTORY INSTALLED POWER CORD INCLUDED WS900E 42" WIDE STONEWOOD BEIGE COLOR INSULATED METAL WALL SLEEVE & PGKOITB STONEWOOD BEIGE COLOR EXTERIOR ARCHITECTURAL GRILLE REQUIRED FOR ALL PTC UNITS. PBWSOIA 26" WIDE STONEWOOD BEIGE COLOR INSULATED METAL WALL SLEEVE & PBAGKO1TB STONEWOOD BEIGE COLOR EXTERIOR ARCHITECTURAL GRILL REQUIRED FOR PBE UNIT. 2. PTC & PBE CHASSIS UNITS TO BE PROVIDED WITH PERMANENT SLIDE -OUT INDOOR INTAKE AIR FILTERS. 3. COOLING CAPACITIES & EER ARE BASED ON AHRI CONDITIONS AT 208/60/1. UNITS SHALL OPERATE AT A MINIMUM OF 197 VOLTS AND A MAXIMUM OF 253 VOLTS. 4. PTC AND PBE CHASSIS UNITS TO BE INSTALLED INTO WALL SLEEVE AND EXTERIOR GRILLE PER NOTE #1. 5. FOR ALL PTC CHASSIS UNITS, FIELD PROGRAM ROOM # INTO PTAC TOUCH PAD. 6. ALL PTC CHASSIS UNITS TO HAVE FACTORY PROVIDED RF ANTENNA TO ENABLE THEM TO BE MONITORED AND CONTROLLED VIA DLO1 E DIGILINK WEB ENABLED PLATFORM CONTROLLER. 5 P ie1 -F I. L... ,TI bS.N OR, Rw ,t ' 0.,-A E,Hw T 8. PROVIDE DS01 E RF WIRELESS WALL THERMOSTAT WITH HONEYWELL-TG512A1009 LOCKABLE COVER & KLO3E KEY LOCK KIT ON ALL PTC153G35RVXX UNITS WITH FACTORY INSTALLED POWER VENT AT END OF CORRIDORS. SEE ARCH PLANS FOR LOCATIONS. 9. UNITS PROVIDED IN NON -GUEST ROOM AREAS (CORRIDORS, ELECTRICAL ROOM) DO NOT REQUIRE DD01 E RF WIRELESS MOTION SENSOR / DOOR SWITCH. 10. NOT USED 35 EXHAUST FAN SCHEDULE MARK MANUFACTURER MODEL SERVES AIRFLOW (CFM) ESP (IN) FAN DATA MOTOR DATA CONTROL TYPE WEIGHT (LBS) REMARKS TYPE RPM SONES DRIVE WATTS VOLTAGE PHASE EF -1 COOK GC -128 GUEST ROOMS 55 0.25 CENTRIFUGAL 708 1 DIRECT 29 120 1 WALL SWITCH 25 1,2,3,4,7,8 EF -2 COOK GC -128 UTILITY ROOM 440 35 0.25 CENTRIFUGAL 587 1.5 DIRECT 29 120 1 CONTINUOUS 25 1,2,3,5,8 EF -3 COOK GC -542 MECHANICAL ROOM 300 0.25 CENTRIFUGAL 1387 4.5 DIRECT 100 120 1 THERMOSTAT 45 1,2,3,5,6,7,8 EF -4 COOK GC -146 RESTROOM 139 75 0.38 CENTRIFUGAL 900 2 DIRECT 36 120 1 SWITCH W/ LIGHTS 25 1,2,3,4,8 RUUD NOT USED UPFLOW GUEST LAUNDRY 0.5 1600 150 4 47.2 34.5 REMARKS: TRANSFORMER & 24V SECONDARY CONTROL RELAY, SURFACE MOUNTING FRAME, SINGLE -POLE THERMOSTAT, AND UNIT MOUNTED DISCONNECT SWITCH. MOUNTED TAMPER RESISTANT LOW VOLTAGE THERMOSTAT(40°F-90°F), POWER DISCONNECT SWITCH, WALL MOUNTING BRACKET. 1. PROVIDE WITH 208/24V 2. PROVIDE WITH UNIT RXBH-1724?07J 5.4 53/85 EF -5 EF -6 COOK GC -128 UTILITY ROOM 340 35 0.25 CENTRIFUGAL 587 1.5 DIRECT 29 120 1 CONTINUOUS 25 1,2,3,5,8 REMARKS: DISCONNECTS, BACKDRAFT DAMPERS, VIBRATION ISOLATION KITS, CEILING RADIATION DAMPERS, AND THERMOSTAT WHERE NOTED AS "CONTROL TYPE". WITH DIRECT DRIVE MOTORS. RELAYS, TRANSFORMERS, TIMECLOCKS, MOTOR STARTERS, ETC. PROVIDED BY THE DIVISION 26 SEE ELECTRICAL PLANS. NON -YELLOWING, HIGH IMPACT STYRENE INJECTION MOLDED CEILING GRILLE. CEILING GRILLE. ONLY THERMOSTAT FOR EF -3. BROAN FANS MAY BE USED, MODEL #L100 (EF -1) AND #L300 (EF -3). FOR FAN TYPES AND ACCESSORIES. 1. PROVIDE WITH FACTORY 2. PROVIDE SPEED CONTROLLERS 3. ALL SWITCHES, INTERLOCKS, 4. PROVIDE WHITE, 5. PROVIDE WHITE ALUMINUM 6. PROVIDE COOLING 7. ACCEPTABLE ALTERNATE 8. REFER TO SPECIFICATIONS UNIT HEATER SCHEDULE MARK MANUFACTURER SERIES MODEL TYPE I SERVES HEATING (BTUH) ELECTRICAL DATA WEIGHT (LBS) REMARKS VOLTAGE PHASE KW AMPS EUH-1 QMARK EFF EFF -4004 ELECTRIC VESTIBULE 135 10,239 208 1 3.0 14.4 23 1 EUH-2 QMARK EFF EFF -4004 ELECTRIC HALL / VENDING 136 10,239 208 1 3.0 14.4 23 1 EUH-3 QMARK EFF EFF -4004 ELECTRIC MECHANICAL ROOM 140 10,239 208 1 3.0 14.4 23 1 EUH-4 QMARK AWH AWH-4404 ELECTRIC STAIRS 152 10,235 208 1 3.0 14.4 • 20 2 EUH-5 QMARK AWH AWH-4404 ELECTRIC STAIRS 150 10,235 208 1 3.0 14.4 20 2 100 1,2,3,4,5 FCU -3 RUUD RHIP4821S UPFLOW GUEST LAUNDRY 0.5 1600 150 4 47.2 34.5 REMARKS: TRANSFORMER & 24V SECONDARY CONTROL RELAY, SURFACE MOUNTING FRAME, SINGLE -POLE THERMOSTAT, AND UNIT MOUNTED DISCONNECT SWITCH. MOUNTED TAMPER RESISTANT LOW VOLTAGE THERMOSTAT(40°F-90°F), POWER DISCONNECT SWITCH, WALL MOUNTING BRACKET. 1. PROVIDE WITH 208/24V 2. PROVIDE WITH UNIT HEAT PUMP SCHEDULE MARK MANUFACTURER MODEL SERVES NOMINAL COOLING (TONS) AMBIENT TEMPERATURE (°F) SEER CORRESPONDING INDOOR UNIT VOLTAGE PHASE MCA MOCP WEIGHT (LBS) REMARKS HP -1 RUUD RP14-36AJ LOBBY'/OFFICE 3 95 14.0 FCU -1 208 1 22 35 175 1,2,3,4 HP -2 RUUD RP14-24AJ STAFF LAUNDRY 2 95 14.0 FCU -2 208 1 14 20 150 1,2,3,4 HP -3 RUUD RP14-36AJ GUEST LAUNDRY 4 95 14.0 FCU -3 208 1 29 50 200 1,2,3,4 FCU -2 RUUD RHIP2417S UPFLOW STAFF LAUNDRY 0.5 800 50 2 28.6 21.2 95 80/67 57/55 REMARKS: TIME DELAY CONTROLS, BI-DIRECTIONAL FILTER DRIER, START KIT, LOW AMBIENT CONTROLS, AND HAIL GUARDS. INDOOR UNIT SCHEDULE FOR ENTERING AND LEAVING TEMPERATURES AT THE COIL. SHALL PROVIDE AND INSTALL DISCONNECT SWITCH FOR EACH UNIT. 1. PROVIDE WITH COMPRESSOR 2. REFER TO ASSOCIATED 3. ELECTRICAL CONTRACTOR FAN COIL UNIT SCHEDULE GENERAL AIRFLOW COOLING HEATING ELECTRICAL MOTOR WEIGHT REMARKS MARK MANUFACTURER MODEL TYPE SERVES ESP (IN) CFM MINIMUM OUTDOOR AIR (CFM) NOMINAL REQUIRED CAPACITY (TONS) TOTAL CAPACITYCAPACITY (BTUH) SENSIBLE (BTUH) AMBIENT AIR (°F) EDB / EWB (°F) LDB / LWB (°F) MODEL TOTAL CAPACITY (KW) EDB / LDB (°F) VOLTAGE PHASE MCA MOCP HP TYPE FCU -1 RUUD r RH1 P3621 S -, UPFLOW LOBBY / OFFICE 0.5 1200 175 3 35.4 25.9 95 80/67 57/55 RXBH-1724?07J 5.4 53/85 208 1 36 40 1/3 DIRECT 125 1,2,3,4,5 FCU -2 RUUD RHIP2417S UPFLOW STAFF LAUNDRY 0.5 800 50 2 28.6 21.2 95 80/67 57/55 RXBH-1724?07J 5.4 53/85 208 1 35 35 1/5 DIRECT 100 1,2,3,4,5 FCU -3 RUUD RHIP4821S UPFLOW GUEST LAUNDRY 0.5 1600 150 4 47.2 34.5 95 80/67 57/55 RXBH-1724?07J 5.4 53/85 208 1 39 40 3/4 DIRECT 150 1,2,3,4,5 - REMARKS: PROVIDE WITH FACTORY FURNISHED PIPING & VALVE KIT. PROVIDE ALL VALVES & ACCESSORIES FOR DX CONNECTIONS. PROVIDE WITH FAN SWITCH, CONTROL TRANSFORMER AND ALL NECESSARY CONTROL ACCESSORIES. PROVIDE WITH (2) SETS OF FILTERS. "`^�'`rrW"Y✓"Z.`vy"'�,," r..`"`y''l^'•1^`"!'Yf"1^''W"Yr'Y,,,'1'✓,"l'r�,.,r^y.✓"1'�" `r.ri^,"1^ MYf-�"'4^"`r'rY^✓"Y.r^r'"1^'l'�+°"r'W'i"yr^.'ry✓'W"1"`"Z^'✓l^,"1-f"ti^'1'.r�. . i"l ROUTE CONDENSATE TO NEAREST FLOOR DRAIN. PROVIDE WATER SENSING SWITCH IN CONDENSATE PAN HIGHER THAN THE PRIMARY DRAIN LINE CONNECTION AND BELOW THE OVERFLOW RIM. THE UNIT SHALL SHUT DOWN UPON ALARM FROM SWITCH, {}(tj PROVIDE THERMOSTAT AND HONEYWELL-TG512A1009 LOCKABLE COVER. 1. 2. 3. 4. 5. Lopz GENERAL NOTES: . EXISTING EQUIPMENT, DUCTWORK, AND PIPING SIZES AND LOCATIONS ARE SHOWN FOR REFERENCE ONLY. ADJUST EXACT INSTALLATION AND CONNECTION OF NEW ITEMS ACCORDING TO ACTUAL CONDITIONS. 1. DEFINITIONS: FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS." PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." 2. ALL WORK SHALL COMPLY WITH CURRENT FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES AS WELL AS THE CONSTRUCTION DOCUMENTS. REPORT ANY CONFLICTS TO THE ENGINEER AS SOON AS THEY ARE DISCOVERED. 3. UNLESS OTHERWISE NOTED, THE WORK DESCRIBED ON THE PLANS AND SPECIFICATIONS SHALL INCLUDE THE FURNISHING AND INSTALLATION OF ALL LABOR AND MATERIALS NECESSARY FOR COMPLETE AND OPERATIONAL HVAC SYSTEM. CONTRACTOR SHALL FURNISH THESE EVEN IF ITEMS REQUIRED TO ACHIEVE THIS (I.E. OFFSETS, ISOLATION AND BALANCING DEVICES, MAINTENANCE CLEARANCES, ETC.) ARE NOT SPECIFICALLY SHOWN IN THE DRAWINGS AND SPECIFICATIONS. DRAWINGS AND SPECIFICATIONS CARRY EQUAL IMPORTANCE AND ITEMS LISTED IN EITHER SHALL BE PROVIDED AS IF LISTED IN BOTH. ALSO REVIEW DETAILS AND RISER DIAGRAMS FOR ADDITIONAL ITEMS/INSTRUCTIONS WHETHER SPECIFICALLY REFERRED TO ON PLANS OR NOT. 4. DATA GIVEN ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED. ABSOLUTE ACCURACY IS NOT GUARANTEED, OBTAIN AND VERIFY EXACT LOCATIONS, MEASUREMENTS, LEVELS, SPACE REQUIREMENTS, POTENTIAL CONFLICTS WITH OTHER TRADES, ETC. AT THE SITE AND SHALL SATISFACTORILY ADAPT THE WORK TO ACTUAL CONDITIONS AT THE BUILDINGS. THE DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND SHALL NOT BE SCALED. HOWEVER, THIS DOES NOT RELIEVE ANY SUB -CONTRACTOR FROM COORDINATING THEIR WORK WITH ALL OTHER TRADES AND FROM ADJUSTING THEIR WORK AS REQUIRED BY THE ACTUAL CONDITIONS OF THE PROJECT. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING A BID TO BECOME THOROUGHLY FAMILIAR WITH THE ACTUAL CONDITIONS OF THE PROJECT. 5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL ITEMS THAT AFFECT OTHER DISCIPLINES WITH THE CORRESPONDING CONTRACTOR AND THE GENERAL CONTRACTOR IF EQUIPMENT, MATERIALS, ETC. OTHER THAN THOSE SCHEDULED AND SPECIFIED (PENDING PRE -APPROVAL) ARE PROVIDED. 6. COORDINATE AND ADJUST ALL WORK BETWEEN TRADES AND EXISTING CONDITIONS IN ORDER TO ACCOMPLISH A NEAT, INTEGRATED AND EFFICIENT INSTALLATION. CHANGE ORDERS WILL NOT BE GRANTED DUE TO LACK OF COORDINATION WITH JOB CONDITIONS AND/OR OTHER CONTRACTORS. 8. GENERAL CONTRACTOR SHALL CUT AND PATCH FLOOR, WALLS, AND ROOF AS REQUIRED FOR INSTALLATION/DEMOLITION OF MECHANICAL SYSTEMS. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR STORAGE OF RELOCATED EQUIPMENT AND MATERIALS DURING CONSTRUCTION. ITEMS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. 10. UPON COMPLETION OF THE PROJECT, PROVIDE AS -BUILT DRAWINGS TO THE OWNER, ARCHITECT, AND ENGINEER SHOWING EQUIPMENT, DUCTWORK, PIPING, ETC. THAT DIFFERS FROM CONSTRUCTION DOCUMENTS AS THEY ARE ACTUALLY INSTALLED. 11. EXAMINE THE CONTRACT DOCUMENTS OF ALL TRADES (I.E. THE ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL LIGHTING PLAN, FIRE PROTECTION PLAN, ETC.). THE RESPONSIBILITY OF EACH CONTRACTOR IS NOT LIMITED TO THEIR SPECIFIC DISCIPLINE'S DRAWING SHEETS. REFER TO OTHER DISCIPLINES' DRAWING SHEETS AS REQUIRED FOR ADDITIONAL INFORMATION/INSTRUCTIONS. 12. FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS. SLEEVE IN ENTIRETY WITH APPROPRIATE SLEEVE MATERIAL. 13. MAINTAIN ALL REQUIRED SERVICE, FRESH AIR, AND ROOF EDGE CLEARANCES FOR ALL NEW AND EXISTING EQUIPMENT, DUCTWORK, AND PLUMBING VENTS. 14. COORDINATE NECESSARY EQUIPMENT, DUCTWORK AND PIPING LOCATIONS SO THAT THE FINAL INSTALLATION IS COMPATIBLE WITH THE MATERIALS AND EQUIPMENT OF THE OTHER TRADES. 15. PREPARE SHOP DRAWINGS FOR INSTALLATION OF ALL NEW WORK BEFORE INSTALLATION TO VERIFY COORDINATION OF WORK BETWEEN TRADES. 16. REFER TO THE ARCHITECTURAL DIVISION FOR EXACT LOCATION OF ALL VISIBLE FIXTURES, EQUIPMENT AND AIR DEVICES. 17. MAINTAIN A MARK-UP SET OF DRAWINGS WHICH INDICATE VARIATIONS IN THE ACTUAL INSTALLATION FROM THE ORIGINAL DESIGN. SURRENDER DRAWINGS TO OWNER UPON COMPLETION. 18. VERIFY THE ELECTRICAL SERVICE PROVIDED BY THE ELECTRICAL CONTRACTOR BEFORE ORDERING ANY MECHANICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. 19. COORDINATE ALL REQUIRED BREAKER SIZES WITH ELECTRICAL CONTRACTOR UPON RECEIPT OF RETURNED SUBMITTALS. NO COST CHANGES WILL BE ACCEPTED FOR FAILURE TO COORDINATE. 20. SUSPEND EACH TRADE'S WORK SEPARATELY FROM THE STRUCTURE. DUCTWORK SHALL BE HELD TIGHT TO STRUCTURE EXCEPT WHERE SHOWN. 21. PROVIDE ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 22. PROVIDE MANUFACTURER'S RECOMMENDED SERVICE CLEARANCE ALL AROUND ALL EQUIPMENT REQUIRING SAME. 23. PROVIDE FOR SAFE CONDUCT OF THE WORK, CAREFUL REMOVAL AND DISPOSITION OF MATERIALS AND PROTECTION OF PROPERTY WHICH IS TO REMAIN UNDISTURBED. 24. PROVIDE ACCESS DOORS FOR ALL EQUIPMENT, VALVES, CLEANOUTS, ACTUATORS AND CONTROLS WHICH REQUIRE ACCESS FOR ADJUSTMENT OR SERVICING AND WHICH ARE LOCATED IN OTHERWISE INACCESSIBLE LOCATIONS. 25. ALL CURBS, ROOF JACKS, ROOF THIMBLES, SANITARY VENTS, ROOF DRAINS, ETC. SHALL BE COMPATIBLE WITH THE ROOFING SYSTEM TO BE PROVIDED. REFERENCE ARCHITECTURAL DIVISION FOR REQUIRED FLASHING DETAILS. 26. ALL DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS. SEE SPECIFICATIONS FOR INSULATION REQUIREMENTS. 27. PROVIDE BALANCING DAMPERS IN EACH GRILLE/DIFFUSER DUCT RUN OUT NOT BEING PROVIDED WITH OBD AT GRILLE (SEE GRILLES, REGISTERS, AND DIFFUSERS SCHEDULE). LOCATE DAMPERS ABOVE ACCESSIBLE CEILINGS. 28. UPON COMPLETION OF INSTALLATION OF NEW HVAC SYSTEMS, ALL SYSTEMS SHALL BE BALANCED BY THE MECHANICAL CONTRACTOR. 29. TRANSITION FROM DUCT SIZE SHOWN ON PLANS TO EQUIPMENT CONNECTION SIZE AT CONNECTION TO EQUIPMENT. 30. WARRANTY: THE ENTIRE MECHANICAL SYSTEM SHALL BE WARRANTED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR AFTER ACCEPTANCE OF THE SYSTEM BY THE OWNER. 31. PROVIDE ALL REQUIRED PERMITS, INSPECTIONS AND COORDIN4TIO GOVERNING AUTHORITIES. INSTALLATION TO CONFORM WITH 438 PROVISIONS OF: A. APPLICABLE LOCAL, STATE AND FEDERAL CODES, LAWS AN REGULATIONS. B. CURRENT BUILDING AND MECHANICAL CODES. C. APPLICABLE PAMPHLETS OF THE NFPA INCLUDING THE NATI ELECTRICAL CODE. D. AMERICANS WITH DISABILITIES ACT (ADA). 32. QUALITY CONTROL: A. SUBMIT CUT SHEETS ON ALL OF THE SPECIFIED EQU B. SUBMIT FOUR (4) COPIES OF ALL SUBMITTALS I REQUIRED BY THE CONTRACTOR AND THEIR SUPPLI.?? ' T A• S ALA i ` SHALL BE RETAINED BY THE OWNER, ARCHITECT AND ENGINEER. SEP 18 2017 B R R Architect of Record: BRR Architecture, Inc. Kansas Oty • 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P 913 322 5150 ® F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with its Issue date and it Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers, Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 9 09/08/17 CCD #5 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES' AN EXTENDED STAY HOTEL Project Manager: J Checked By: CF/AR Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal WED FOR COMPLIANCE APPROVED PERMIT CENTER NOTE: NO SUBSTITUTIONS OF VENDORS OR PRODUCT ON EQUIPMENT UNLESS APPROVED BY WOODSPRING SUITES, THE ARCHITECT AND THE OWNER. 11 0019) REVISION NO.L EXPIRES: 09/21/17 Sheet Title MECHANICAL NOTES, SCHEDULES, AND LEGENDS Sheet No. M -1 BRR Original printed on recycled paper 5/24/2017 10:01:56 AM • : : . . • i ! I ' : • : . . • . 1 t , ,.... .• k' : : ROUTE DUCT WITHIN FIRE RATED ASSEMBLY FROM FAN TO EXTERIOR WALL HOOD. ....... . EXHAUST DUCTWORK DETAIL - FIRST SECOND & THIRD FLOORS 2 SCALE: NOT TO SCALE PTAC 1 UTILITY ROOM 1 1 240 1 DELUXE KING 225] DOUBLE QUEEN SUITE 12231 DOUBLE QUEEN. SUITE L.. 1221 1 3-- DOUBLE....1 QUEEN' • -- SUITE 12191 4"0 I 1 PROVIDE FIFE RADIATION DAMPER WITH EXHAUST FANS (TYP. LL LOCATIONS) CORRIDOR 200 5"0 EXHAUST WALL CAPS WITH GRAVITY DAMPERS. (TYP) !if it, t! •• QUEEN SUITE 234 1 • DOUBLE QUEEN SUITEI 11 ACC. DOUBLE QUEEN SUITE 222 1 (L= DOUBLE QUEEN 1 SUITE 1220 1 DELUXE \ CORNER \ SUITE QUEEN/ SUITE '3 PTAC) 1 1 226 1 1224 1 PTAC \ 1 8 MECHANICAL SECOND FLOOR PLAN SCALE: 1/8" = 1'0" PTAC MOUNT /VTHERMOSTAT AT A.F.F. AND PROVIDE WITH • LOCKABLE COVER. \'' QSUUEI TEEN /\ PTAC BALANCE OUTDOOR AIR TO 125 CFM. REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 14 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 2 5 2017 PERMIT CENTER Architect of Record: BRR Architecture, Inc. Kansas aty Bentonville Phoenix San Francisco Philadelphia Atlanta Miami 6700 Antioch Plaza Suite 300 Merriam, KS 66204 Tel: 913-262-9095 Fax: 913-262-9044 Consultants ACE RTUS CONSULTING GROUP, LLC 14817 West 951h Street • Lenexa, Kansas 66215 P 913 322 5150 • F 913 322 5155 www.AcertusGroup.com Copyright Notice Thls drawing was prepared for use on a specific site contemporaneously with Its issue date and it Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title MECHANICAL SECOND FLOOR PLANS Sheet No. M=23 0 BRR Original printed on recycled paper 5/24/2017 10:02:01 AM f. <PTAC 1 STAIRS UTILITY ROOM :DOUBLE QUEEN_...__ SUITE DOUBLE QUEEN SUITE ir) DELUXE KING SUITE DOUBLE QUEEN SUITE DOUBLE 'QUEEN SUITE .-. 1 323 1 1 321 1 R1 6"x6" HALL CORRIDOR PROVIDE FIRE RADIATION DAMPER WITH EXHAUST FANS (TYP. ALL LOCATIONS) CORRIDOR 300 1 (TYP OF 32 DOUBLE QUEEN SUITE 5"Y EXHAUST WALL CAPS WITH GRAVITY DAMPERS. (TYP) QUEEN SUITE QUEEN, SUITE DOUBLE QUEEN DOUBLE QUEEN DOUBLE QUEEN SUITE 1 334 1 1 332 1 ACC. DELUXE KING SUITE 1322 1 DELUXE �. CORNER SUITE C/PTAC ACC. QUEEN, , SUITE •1. 324 1 j 'CORRIDOR 1 6 MECHANICAL THIRD FLOOR PLAN SCALE: 1/8" = 1'-0" MOUNT THERMOSTAT AT 4'-0" A.F.F. AND PROVIDE WITH LOCKABLE COVER. /PTAC QUEEN SUITE QUEEN SUITE STAIRS i Mt7 BALANCE OUTDOOR AIR TO 125 CFM. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 14 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 2 5 2017 73 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas (My 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P 913 322 5150 ® F 913 322 5155 www.AceriusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and It is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproductlon of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 \/ WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title MECHANICAL THIRD FLOOR PLAN Sheet No. M-4 0 BRR Original printed on recycled paper 9/7/2017 4:37:06 PM FIRE ALARM RELAj\ A B H N 120 VAC SPRING RETURN NORMALLY OPEN NORMALLY OPEN DAMPER WITH 120 VAC SPRING RETURN ACTUATOR DAMPER EQUAL TO RUSKIN CD -36 LOW LEAK CONTROL DAMPER. INTERLOCK DAMPER TO OPEN ON DETECTION OF SMOKE IN ELEVATOR LOBBY. DAMPER SIZED TO FIT INSIDE ROOF CURB. ELEVATOR SHAFT ROOF HOOD ROOF CURB, MIN. 14" HIGH ROOF ELEVATOR SHAFT VENT CONTROL: A NORMALLY OPEN DAMPER LOCATED AT THE TOP OF THE ELEVATOR SHAFT SHALL BE CONTROLLED BY THE BUILDING FIRE ALARM CONTROL SYSTEM. THE DAMPER SHALL REMAIN CLOSED UNDER NORMAL CONDITIONS. UPON ACTIVATION OF A SMOKE DETECTOR LOCATED IN ANY ELEVATOR LOBBY OR A SIGNAL FROM THE FIRE ALARM CONTROL THE DAMPER SHALL OPEN AND REMAIN OPEN UNTIL THE ALARM CONDITION IS CLEARED AND A SIGNAL IS GENERATED FROM THE FIRE ALARM CONTROL SYSTEM FOR THE DAMPER TO CLOSE. 4 ELEVATOR SHAFT RELIEF HOOD DETAIL SCALE: NOT TO SCALE 12"x6' TITUS 350FL, EXHAUST AIR GRILLE LOCATED IN SOFFIT OR EXHAUST FAN MANUFACTURER SOFFIT GRILLE AND EAVE ELBOW. (TYP) to X x STAIRS UTILITY ROOM DOUBLE QUEEN _---._-_- SUITE DOUBLE QUEEN SUITE 1429 1 T1 6"x6" DOUBLE , ' \ \ ,'j QUEEN SUITE \ /`r��/ //` - \' CORRIDOR PROVIDE FIRE RADIATION DAMPER WITH EXHAUST FANS (TYP. ALL LOCATIONS) CORRIDOR ti QUEEN. SUITE 14341 (PTAC) LG. ACC. DELUXE KING DOUBLE QUEEN SUITE 14241 DOUBLE QUEEN._ SUITE 14221 14201 CORRIDOR MECHANICAL ROOF PLAN SCALE: 1/8" =11-0" 5"0 EXHAUST WALL CAPS WITH GRAVITY DAMPERS. (TYP) 7' ./ // �PTAC\ MECHANICAL FOURTH FLOOR PLAN SCALE: 1/8" = 1'-0" 4"0 QUEEN SUITE :. MOUNT THER OSTAT AT \ 4'-0" A. . AND ---PROVIDE ITH LOCKABL , COVER. \// \% \ //^ ORRIDOR X4001 / QUEEN SUITE 14031 12"x6" TITUS 350FL, EXHAUST AIR GRILLE LOCATED IN SOFFIT OR EXHAUST FAN MANUFACTURER SOFFIT GRILLE AND EAVE ELBOW. (TYP) PROVIDE FIRE RADIATION DAMPER WITH EXHAUST FANS (TYP ALL LOCATIONS) QUEEN SUITE`. \, \ / `QUEEN SUITE QUEEN SUITE / 14021 SEP 2 6 2017 EXHAUST DUCTWORK DETAIL - FOURTH FLOOR SCALE: NOT TO SCALE BALANI OUTDO AIR TO 125 CF City of Tukwila 'BUILDING DI ISION STAIRS i i RECEIVED CITY OF TUKWILA SEP 18.2017 PERMIT CENTER M117�,vxe;;ifi����. l.`�1 fi` ,e t073 B R R Architect of Record: BRR Architecture, Inc. Kansas City 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Phllanelphla Atlanta Tet: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street 4 Lenexa, Kansas 66215 P 913 322 5150 0 F 913 322 5155 www.AceriusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with its issue date and it Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 6 05/31/17 CCD #2 9 09/08/17 CCD #5 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES' AN EXTENDED STAY HOTEL Project Manager: Checked By: CF/AR Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title MECHANICAL FOURTH FLOOR PLAN Sheet No. M-5 BRR Original printed on recycled paper