Loading...
HomeMy WebLinkAboutPermit M17-0074 - DATE RESIDENCE - HEAT PUMP AND THERMOSTATDATE RESIDENCE 4103 S 130T" ST M17-0074 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 7340600821 4103 S 130TH ST DATE RESIDENCE MECHANICAL OTC PERMIT Permit Number: M17-0074 Issue Date: 5/25/2017 Permit Expires On: 11/21/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: DATE BRIAN + VICKIE 4103 S 130TH , SEATTLE, WA, 98168 KATRINA SIMONSON 1813185 ST E , BONNEY LAKE, WA, 98391 GREEN CITY HTG & A/C INC 948 INDUSTRY DR , TUKWILA, WA, 98188 GREENCH866B2 Phone: (206) 227-6616 Phone: (206) 227-6616 Expiration Date: 1/22/2018 DESCRIPTION OF WORK: INSTALL A LENNOX HEAT PUMP & THERMOSTAT Valuation of Work: $7,500.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $245.63 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code. Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per it and agree to the conditions attached to this permit. Signatur Print Na t a SI vv\oin.ca h 70/7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Type 1 Hoods, the required grease duct leakage test and light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov i Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION //�� Kink() Assessor's Tax No.:13 40 (O 00%2... 1 Site Address: `i O S . \ � ST Suite Number: Floor: Tenant Name: V sa- B� (l �( .� New Tenant: ❑ Yes ❑..No PROPERTY OWNER CName: GrerC\- Ci 'hi Address:c tl 1r uS ®r Name: Vn.(`��a. Email: orpenc.vivituar 63 nixtti 1. a Address: q 103,_ s ' a s -r City U�i�l� 31 Q State: Zip: q %I LA CONTACT PERSON — person receiving all project communication CName: GrerC\- Ci 'hi Address:c tl 1r uS ®r City:t_� � Stat .�p ZipgC, `C nc/ �1 O O si Phonej�Ujx�,.�, _ ,�. j , Lob / / Fax: Email: orpenc.vivituar 63 nixtti 1. a J MECHANICAL CONTRACTOR INFORMATION Company Name rc moi, 1 .t.0 \ YIC.- AddressrHis. l arks b r City:�.v J13.�1 LCA state Zip:q% i$% �l Phone. 22-1 , cola ` LFax: Contr RegNo.Ge£ ENCKF.blo 167 1- 1 _ zz-I & Tukwila Business License No.:8 os 790%1,3 Valuation of project (contractor's bid price): $ —757)0 . (a® Describe the scope of work in detail: 1 V1S`{ R. (1 a_d poi/1(p et- T „eat Use: Residential: New ❑ Replacement Commercial: New ❑ Replacement / ❑ Fuel Type: Electric..) Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-I6.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 1 Suspended/walUfloor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 1 Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper. Residential, Nighttime Diffuser Industrial Thermostat 1 45 dB(A) 57 dB(A) 60 dB(A) Commercial Wood/gas stove 47 dB(A) Emergency generator 65 dB(A) Other mechanical equipment 60 dB(A) 50 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORLZED TO APPLY FOR THIS PERMIT. BUILDING O ER t R AUTHORIZED AGENT: .rr Sign.'' Date: S l 1 -' 7 Print Name: Kgt S\vY\Xi&OV\. Day Telephone62040 ' 11-1 ' V0 lQ 1 CO Mailing Address: "1 + 1 hda-i-S\Th(VA6v- ki (& /-k "l O1 City State Zip H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY PAID $368.21 EL17-0399 Address: 41035130TH ST Apn: 7340600821 $122.58.: ELECTRICAL $116.74 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $116.74 TECHNOLOGY FEE $5.84 TECHNOLOGY FEE 1 R000.322.900.04.00 0.00 I $5.84 M17-0074. Address:. 4103 S 130TH ST Apn: 7340600821 $245.63 MECHANICAL $233.93 PERMIT FEE R000.322.100.00.00 0.00 $200.78 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $11.70 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11578 R000.322.900.04.00 0.00 $11.70 $368.21 Date Paid: Thursday, May 25, 2017 Paid By: GREEN CITY HTG & A/C INC Pay Method: CHECK 6558 Printed: Thursday, May 25, 2017 3:31 PM 1 of 1 CANWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit /1/1/7-06`741 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 l.�'�E'� project: Type of Inspection: Address: 11100Z .5 i 20114 Sr. Date Called:, Special Instructions: • Date Wanted 7/J4///7 a.m. p.m. Requeste . Phone No: Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: Ct. To ��✓e,c.s Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Green City HTG & A/C INC Home Espanol Contact Safety & Health Claims & Insurance 41/1114 Washington State Department of 4 Labor & Industries Search L&I Page 1 of 3 A -'L Index Help My L8d Workplace Rights Trades & Licensing Green City HTG & A/C INC Owner or tradesperson Principals Simonson„ Jeffrey Orvold, PRESIDENT Simonson, Katrina Marie, SECRETARY Doing business as Green City HTG & A/C INC WA UBI No. 603 363 739 948 INDUSTRY DR TUKWILA, WA 98188 206-227-6616 KING County Business type Corporation License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. GREENCH866B2 Effective — expiration 01/22/2014— 01/22/2018 Bond ................. Wesco Insurance Co Bond account no. 46WB079066 $6,000.00 Received by L&I Effective date 08/25/2016 08/19/2016 Expiration date Until Canceled Bond history Insurance ............................... Arch Specialty Ins Co $1,000,000.00 Policy no. AGL0043156.00 Received by L&I Effective date 11/17/2016 11/18/2016 Expiration date 11/18/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603363739&LIC=GREENCH866B2&SAW= 5/25/2017 Green City HTG & A/C INC Cause no. 16-2-02889-6 Complaint filed by NADA & JAMES DOHERTY Complaint date 02/10/2016 Open ................ Complaint against bond(s) or savings 100180935 Complaint amount $0.00 L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. EJOJP00385 Issue date 08/26/2015 Violation city BONNEY LAKE Type of violation ELECTRICAL CITATION Description - Class B eligible work - Failure of the:person identified as the installer on the Class B label to post a Class B label, or number if allowed. (See WAC 296-46B-908.) 15448 SE 167 PL, RENTON Satisfied ......................... RCW/WAC 19.28.101 RCW Violation amount $100.00 Infraction no. EJOJP00386 Satisfied ......... _............... RCW/WAC Issue date 08/26/2015 Violation city BONNEY LAKE Type of violation ELECTRICAL CITATION Description Offering, bidding, advertising, or performing electrical installations, alterations or maintenance outside the scope of the firm's specialty electrical contractors license. Infraction no. EJOJP00388 Issue date , 08/26/2015 Violation city BONNEY LAKE Type of violation . ELECTRICAL CITATION Description Energizing electrical`equipment without an . •electrical inspection -as referenced in WAC 296-46B-901. ' Infraction no. EJOJP00387 Issue date 08/26/2015 Violation city BONNEY LAKE Type of violation ELECTRICAL CITATION Description Employing an individual for the purposes of chapter 19.28 RCW who does not possess a valid certificate of competency or training certificate to do electrical work. 19.28.041 RCW Violation amount $500.00 Satisfied RCWM/AC 19.28.101 RCW Violation amount $250.00 Satisfied ......................... RCW/WAC 19.28.271 RCW Violation amount $250.00 Page 2 of 3 Help us improve https://securedni.wa.gov/verify/Detail.aspx?UBI=603363739&LIC=GREENCH866B2&SAW= 5/25/2017