Permit M17-0075 - WELLS FARGO - DUCTLESS SPLIT SYSTEM
WELLS FARGO 18035 SPERRY DR MI 7-0075 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2623049094 18035 SPERRY DR WELLS FARGO MECHANICAL PERMIT Permit Number: M17-0075 Issue Date: 6/22/2017 Permit Expires On: 12/19/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: HIGHLAND PARK PROPERTIES L 495 ANDOVER PARK BLVD E , TUKWILA, WA, 98188 JESSE CHUTICH 3202 C ST NE , AUBURN, WA, 98002 COMFORT MECHANICAL INC 3202 C ST NE , AUBURN, WA, 98002 COMFOM1015LA Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: 4/25/2018 DESCRIPTION OF WORK: REPLACE (1) DUCTLESS SPLIT SYSTEM WITH NEW 2 -TON SYSTEM Valuation of Work: $3,815.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $258.87 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City. of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Date: .);.-17 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: V .S 'c4 Date: 6V 2 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0609 0705 0701 MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKWIL.1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. 117\ 00475 Project No. Date Application Accepted. (p f 7 Date Application Expires tk5`.. 6 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION 9O s S" Site Address: /44111196- perr Y I : we. King Co Assessor's Tax No.: 36'230c/106N" Suite Number: Floor: Tenant Name: \*/P,I(S rOkr10 Gill" K S�rvar &Oh* New Tenant: ❑ Yes J2'.No PROPERTY OWNER Name: Des S� G A,-►,/LiGi, Name: wells Fac10 .4.$ Gorr, irac-ior Tukwila Business License�Lls _ No.: JJ U�� �oS Address: SA.11,4, a s S :-.1.t.. Phone: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Des S� G A,-►,/LiGi, City:Stately/ Zip: OO Z A'tbc",r» Address: sc.h-, c .4.$ Gorr, irac-ior Tukwila Business License�Lls _ No.: JJ U�� �oS City: State: Zip: Phone: Fax: Email: MECHANICAL CONTRACTOR INFORMATION Company Name: G 0P141- f' A4eGAayn:Ga( Address: '3241 G 1-4_ ,A/E City:Stately/ Zip: OO Z A'tbc",r» Phone:g25- z...-7 409 Fax: Contr Reg No.69A,‘ Fejti fariciyAcp Date:/ 5477 � Tukwila Business License�Lls _ No.: JJ U�� �oS Valuation of project (contractor's bid price): $ 3 8f S" Describe the scope orf work in detail: 11 R�tecc 2 (j dei c4fe55 �l < 4- Sys `/Pik'+ '7 k)e-c-' 2 - Tm }-7 SYS'—eft'' Use: Residential: New ❑ Replacement Commercial: New .: ❑ Replacement Fuel Type: Electric Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-0-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Conunercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Noise: Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Conunercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Conunercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) • Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound.levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard'frotn within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Conunercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) • *Daytime means 7AM-10PM, Monday through•Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I.AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O _.:.i ; OR AUTHO Signature: ZED AGENT: Print Name: JP�ss.� 6 t4 !`J/ Mailing Address: 3 20 2—Ci .S NO H:\Applications\Forna-Applications On Line \20I6 Applications\Mechanical Permit Application Revised I-0-16.docx Revised: January 2016 bh Date: Day Telephone: —1 Z S ZS"( 2i,S A >rn W74- ,f0OZ City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $258.87 M17-0075 Address: 18035 SPERRY DR Apn: 2623049094, $258.87 Credit Card Fee $7.54 Credit Card Fee R000.369.908.00.00 0.00 $7.54 MECHANICAL $241.66 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $160.18 PLAN CHECK FEE R000.322.102.00.00 0.00 $48.33 TECHNOLOGY FEE $9.67 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11625 R000.322.900.04.00 0.00 $9.67 $258.87 Date Paid: Monday, June 05, 2017 Paid By: JESSE CHUTICH Pay Method: CREDIT CARD 215041 Printed: Monday, June 05, 2017 10:14 AM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit -7S PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 981 8 ( 6) 431-3670 Permit Inspection Request Line (206) 438-935;� Project::T Wats r4 -06-r) pe of Inspection: 6c►f�+Anc ' AI4/...., Adddress:Date O NS_ -- We fi 1 b , Called: Date Wand: 61/ 7 {a.m. Spe ct ons: Requester: RAAJ Phone No: Zoe / . i 17 / r lei Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fie must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection! PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0075 DATE: 06/05/17 PROJECT NAME: WELLS FARGO SITE ADDRESS: 18035 SPERRY DR X Original Plan Submittal Revision # Response to Correction Letter # Revision # before Permit Issued after Permit Issued DEPARTMENTS: kJ AU kilMil Building Division Public Works 4,AA AVA-- Lo -n-17 Fire Prevention Structural Planning Division nPermit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 06/06/17 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 07/04/17 Notation: REVIEWER'S INITIALS: DATE: EPerniit Center Use Only _--__. _ _ _ CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 'Staff Initials: 12/18/2013 COMFORT MECHANICAL INC Horne Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & industries Search L&I Page 1 of 2 A -Z index Help My Uzi Workplace Rights Trades & Licensing COMFORT MECHANICAL INC Owner or tradesperson Principals JACKSON, SHIRLEY A, PRESIDENT JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA 98002 425-251-9840 KING County Business type Corporation Governing persons HERB JACKSON SHIRLEY A JACKSON; License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOMI015LA Effective --.expiration 06/01/1999— 04/25/2018 Bond Lexon Ins Co Bond account no. 9815017 $6,000.00 Received by L&I Effective date 06/04/2012 06/01/2012 Expiration date Until Canceled Bond history Insurance . . .......................... AMCO Ins Co $1,000,000.00 Policy no. ACP3008276478 Received by L&I Effective date 05/24/2017 06/01/2017 Expiration date 06/01/2018 Insurance history Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 6/22/2017 COMFORT MECHANICAL INC Savings No savings accounts during the previous 6 yew , zriod. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ........................................ No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ........................................ _ ............. No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 973,224-00 ................................ Doing business as COMFORT MECHANICAL INC Estimated workers reported Quarter 1 of Year 2017 "21 to 30 Workers" L&I account contact Employer Services Help Line — 360.902-4817 Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 10/16/2012 Inspection no. 316456144 Location 444 Valley Mall Parkway East Wenatchee, WA 98802 Violations Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601054041&LIC=COMFOMI015LA&SAW= 6/22/2017 VICINITY MAP N.T.S. TAX PARCEL 3623049094 LEGAL DESCRIPTION EXISTING OFFICE BUILDING AREA OF WORK EXISTING PARKING LOT PROJECT DESCRIPTION: 1. REPLACE (1) 1.5 -TON DUCTLESS SPLIT SYSTEM WITH NEW 2 TON DUCTLESS SPLIT SYSTEM INCLUDING ROOFTOP CONDENSING UNIT AND INDOOR AIR HANDLER TO SERVE SERVER ROOM. GENERAL NOTES: 1. SYSTEM DOES NOT HAVE ECONOMIZER PER IMC403.3.1 EXCEPTION 10. 2. INSTALL GFCI OUTLET WITHIN 25' OF CONDENSING UNIT. 3 CONDENSING UNIT TO SIT ON 4X4 PRESSURE TREATED WOOD SLEEPERS WITH SHEET METAL CAPS. 4. PROVIDE COMMISSIONING REPORT. 5. (5) SERVER RACKS AND (1) MONITOR = 5,900 WATTS 5,900 WATTS X 3.412 = 20,131 BTUS 21,500 BTU DUCTLESS SPLIT. SITE PLAN NTS. PORS. OF' GL 4 & OF GI 1 IN SEC 35 LY S OF ild LN EXTND . DAF BEG AT NW COR OF SEC 36 TH S ALG W LN THOF. 1355.89 FT TO TPOB & S MGN OF. S 180TH ST. TH ELY ON CRV LFT CTR BRG N 02-45-45 E RAD 336 FT C/A Oi-32-04 A DIST OF 9 FT TO S LN. OF N 36 FT OF SD GL 4•TH S 88-46-19 E ALG SD S.LN 274.81. FT TH ON CRV RGT RAD 50 FT C/A 90-00-00 A DIST OF 78.54 FT TH S 01-13-41 W 58 FT TH N 88-46-19 W TO SWLY. LN OF GL 1 IN SEC 35 TH.NWLY ALG SD SWLY LN TO WLY EXT OF N LN OF SD GL 4 TH S 88-46-19 E ALG SD WLY EXT TAP 142.38 FT W OFNW COR SD GL 4 TH ON CRV LFT CTR BRG N 27-59-36 E RAD 336 FT 147.96 FT TO TPOB REFRIGERANT AND CONDENSATE PIPING ROOF PENETRATION CU -1 (OUTDOOR) REVISIONS No changes shalt be made to the scope of work without prior approval of Tukwila Building Division. I NOTE.: Revisions will require a new plan submitiai and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: O Mechanical L4�E`ectrical Qdslumbing Ias Piping City of Tukwila BUILDING DIVISION PARTIAL ROOF PLAN EXISTING OFFICE 101 AH -1 (INDOOR) d EXISTING OPEN OFFICE 100 OFFICE FLOOR PLAN 1/4" = 1'-0" NEW SERVER ROOM 103 {' *WM' REFRIGERANT PIPING ROUTE ABOVE CEILING TO (E) ROOF PENETRATION nu COPY Permit No. ` 0.1S Plan review pT.)rovel is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or. ordinance. Receipt of approved Fieidi Copy and conditions is acknowledged: Date: a City of Tukwila BUILDING DIVISION • REVIEWED FOR CODE COMPLIANCE APPROVED JUN 1�7 Oity of Tukwila BUILDING_3LVgS1O M17 RECEIVED CITY OF TUKWILA JUN 052017 PERMIT CENTER W7S r+' 1 REVISIONS. • w CO>«� O 2 «, 0 0 a, ©rC LL >. cn Lo C w co 00 IL - ..I w DATE SCALEI 'DRAWN: CHECKEDZ roAIKIN Submittal Data Sheet 2.0 -Ton Walt Mounted Unit FTXS24LVJURXS24LVJU FEATURES • Intelligent eye occupancy sensor • Weekly timer for programmable comfort • Low ambient heat operation down to 0' F e Titanium apatite photocatalytie air purifying e 12 year timfted parts and compressor warranty with online registration INDOOR UNIT •�+,s-!R CERTIFIED R-41 OA INVERTER' Submittal Data Sheet 2.0 -Ton Wall Mounted Unit FTXS24LVJURXS24LVJU Indoor Unit Model No. Outdoor Unit Model No. Rated Cooling Capacity (Btu/hr): BENEFITS e Quiet operation OUTDOOR UNIT FTXS24LVJU Indoor Unit Name: FTXS24LVJU RXS24LVJU Outdoor Unit Name: RXS24LVJU 21,500 Rated Cooling Conditions: 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all.R1 = �' MECH �5 SUM Mechani.cai; Summar ..,r 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Information Protect Title: WELLS FARGO BANK LOCKBOX Date 1/1/2015 System or Primary Supply Fan ID Applicant Information. Provide contact Information for Individual who can respond to Inquiries about compliance form Information provided. For Building Dept. Use System Total Nameplate HP ,(Note 3) . Company Name: Comfort Mechanical AH -1 Company Address: 3202 C st NE Auburn, WA 98002 AIR HANDLER Applicant Name: Jesse Chutich No Applicant Phone: 4252519840.0 Project Description Briefly describe mechanical systems In the text box provided CONDENSING UNIT ■ New Building ■ Building Addition ■ Tenant Improvement 1 System Retrofit • No System Changes Replace (1) 1.5 -ton ductless split sytstem with new 2 -ton system. • Total Bldg Performance (TBP) This path Includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required Design Load Calculations heating, cooling or Includes all applicable 1 Load catcuiation summary 1 MECH-LOAD-CALC Form Provide design load calculations fora0 mechanical systems and equipment serving the building ventilating needs. If a load calculation summary Is provided with the permit documents that compliance Information then the MECH-LOAD-CALC fort Is not required. Mechanical Schedules forms are not required, IS Mechanical Plans 1 MECI-1-EQ Forms (TBD) Indicate location of equipment compliance Information. if provided on plans then MECH-EQ however, include on plans all applicable compliance Information listed In MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate fire station occupancies) air in a manner that does heating or cooling is required. Exception 1) of DOAS (C403.6, Exception library or fire station) C402.4.1.4 with 100% of • DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no IN Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, • Ventilation and space conditioning provided by a HEVAV system per C403.7 In lieu 2 ■ DOAS included in project, although not required (occupancy not office, retail, education, • DOAS related allowances included in project 1 Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area in building served by DOAS. 1 Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power exceeds 5hp. 5 horsepower threshold. El Project includes HVAC air distribution systems that provide heating and/or cooling ifyes, provide a MECH-FANSYS-SUM form. • For one or more systems, the total fan motor nameplate hp of all fans in HVAC system If yes, provide a separate MECH-FANSYS form for each HVAC system exceeding the Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems • Hydronic chilled water ❑ Water -loop heat pump • No hydronic systems ❑ Hydronic heating water 1 Geothermal C406 Additional Elfiflency Options - Mechanical or air -to -water heat be 15% more efficient than have FEQ a 71 and must be required ventilation air In a annual hot water energy use be • C4062 More efficient I-IVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed In tables C40323(1)-(9) pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must minimum requirements. Alt stand alone supply, return, and exhaust fans over 1hp must selected within 10% of maximum total or static pressure. • C406.6 Dedicated outdoor sir system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers manner that does not require space conditioning fan operation. • C406.7 Reduced energy in service water heating Requires 90% of floor area be In occupancy types listed In C406.7.1 and that 60% of provided by heat pump, waste heat recovery or solar water -heating systems. Indoor Cr DB/WB): 80/67 Ambient (°F D8/W13): 95175 Sensible Capacity (Btulhr): 16,880 Max/Min Cooling Capacity (Stu/hr): 25,80017.800 Cooling Input Power (kW): 1.720 Rated Piping Length(ft): Rated Height Difference (ft): Rated Heating Conditions: 65.60 Indoor (-F DB/WB): 70 / 70 Ambient (-F DBTWB): 47 / 43 SEER (Non-Ducted!Ducted): 20.00 / EER (Non-Ducted/Ducted): 12.50 / Rated Heating Capacity (Btu/hr): 25,400 HSPF (Non-Ducted/Ducted): 10.61 Heating COP (Non-Ducted/Ducted): 3.4 / Max/Min Heating Capacity (Btu/hr): 31,400 / 7,800 Heating Input Power (kW): 2.21 SYSTE Refrigerant Type: Holding Refrigerant Charge (Ills): Additional Charge (ib/ft): R -410A Cooling Operation Range ('F DB): 6.7 Heating Operation Range CF WB): 021 Pre -charge Piping (Length) (ft): Max. Pipe Length (Total) (ft): 98 Max Height Separation (Ind to Ind ft): 66 Max. Pipe Length (Vertical) «1): Cooling Range w/Batfle (-F DB): 14 -115 5-64 0 -115 Heating Range w/Baffle (-F WB): 0 - 77 DAIKIN Submittal Data Sheet 2.0 Ton Wall Mounted Unit FTXS24LVJURXS24LVJU OR UN T DETAIL Power Supply (V/Hz/Ph): Power Supply Connections: 208-230 / 60 / 1 Airflow Rate (HMI/1/SL) (CFM): 643/494/350/328 L1,1.2, Ground Moisture Removal (Gal/hr): 9.6 Min. Circuit Amps MCA (A): Max Overcurrent Protection (MOP) (A): ------ •. Gas Pipe Connection (inch)`.--------•- 5/8 Liquid Pipe Connection (inch): 1/4 Dimensions (HxWxD) (in): 133/8 x 41-5/16 x 9-3/4 Condensate Connection (inch): 5/8 Panel (HxWxD) (in): Sound Pressure (H/MIIJSL) (dBA): 51/34137/34 Net Weight (Ib): 31 Sound Power Level (dBA): 67 Panel Weight (lb): DIMENSIONAL DRAWING - INDOOR UNIT LEFT THE MARK (') SHOWS PIPING DIRECTION f REAR 41-5/16 (1050) REAR I i RIGHT FRONT GRILLE FIXING SCREWS FLAPS (INSIDE) -- SIGNAL TRANSMITTER 21/4 (58) 3/4 8) 1 x D • o WIRELESS REMOTE CONTROLLER (AR0452A9) /HORRIZONT CBLADE ) COOLING Ext. Static Pressure (Rated/Max) (inWg): 0.00 / 0.00 (SPACE FOR MAINTENANCE) MINA .15/16(50) AIR FLOW(INDOOR) (FOR PERFORMANCE A140 MAINTENANCE) /////////////////1/////////////// 1111/////////////////////z/./ I ' i INCLUDING `INSTALLATION PLATE 9-7/16 (240) OPERATION LAMP SIGNAL RECEIVER INDOOR UNIT 0NOOFF SWITCH ROOM TEMP.THERMISTOR (INSIDE) INTELLIGENT EYE SENSOR TIMER LAMP HOME LEAVE LAMP 9-3/8 (238) m F.; BLADE ANGLES DRY 40° 35• / MODEL NAME PLATE TER)fi4ALS.00 (Y/M1 EARTH TERMINAL (INSIDE) MIN.1-15116 (50 (SPACE FOR MAINTENANCE) REQUIRED SPACE GAS PIPE (1/2 CuT (THE LENGTH OF PIPE OUTSIDE THE UNIT: ABOUT 133/8) UQUID PIPED /4 CuT (THE LENGTH SIDE TH UNiTPABOUTIPE U15 3/8) DRAIN HOSE FOR VPI3 (CONNECTING PART I.D.9/16, OD. 11/16) (THE HOSE LENGTH OF OUTSIDE THE UNIT: ABOUT 17-5/16) WALL HOLE FOR EMBEDDED PIPING 13VB HOLE 315/1 (99.5) WALL HOLE STANDARD LOCATIONS OF WALL HOLES f3 -1B HOLE et - 30062861 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Ccono'nizer XceptIonS 2015 Washington State Energy Code Compliance Forms far Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: WELLS FARGD BANK LOCKBOX Date 1/1/2015 All cooling systems shall be configured to provide air economizer operation, regardless of system capacity, for new construction and mechanical system alterations. Various exceptions to this requirement are available. Identify all systems that an economizer exception will be applied to and additional information as noted below. For Building Dept. Use Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS Exp 1 Cooling equipment serving spaces that are provided with a dedicated outdoor air system (DOAS) per C403.6. Spaces served shall have year- rtund design cooling loads from lights and equipment Tess than 5 watts per square foot. System ID Lighting + Equipment Loads (Wlsf) Exp 2 S'ngle zone unitary or package systems with dehumidification that affect oher systems such that air economizer would increase energy consumption. System ID Exp 3 I-fgh efficiency single zone unitary or packaged systems. Equipment cooling efficiency shall be better than the WSEC required minimum efficiency by at feast 64% in Climate Zone 4C and 59% in Climate Zone 5B per Table C403.3. System ID Exp 4 Equipment that provides hydmnic chilled water for chilled beams and culled ceiling systems that is served by a water economizer system per 0103.3.4 in lieu of air economizer. System ID Exp 5 . Water -source heat pumps with heat recovery. Heat pump efficiency shall be 15% better than WSEC required minimum efficiency. Provide at rrinimum 60% air economizer. Energy recovery to preheat OSA shall have at least 50% effectiveness. Additional system requirements apply. System ID Exp 6 Cooling equipment serving Group R occupancies. Per unit limit is less than 20,000 Btu/h cooling capacity for equipment installed ortdoors or in a mech room adjacent to the outdoors. For cooling eluipment installed in other locations the unit limit is less than 51,000 Btu/h. Efficiency shall be 15% better than WSEC required minimum efficiency. System ID Equipment Location Cooling Capacity (Btu/h) Exp 7 Variable refrigerant flow (VRF) systems with energy recovery. Outdoor wit shall be a reverse -cycle heat pump with variable speed crmpressor(s) and condenser fan(s). Outdoor unit cooling capacity shall bs not less than 65,000 Btu/h. Energy recovery to preheat outdoor air stall have at least 50% rated effectiveness. System shall be capable of p-oviding simultaneous heating and cooling by tranferring recovered energy from zone(s) in cooling mode to other zone(s) that are in heating mode. Outdoor Unit System ID Cooling Capacity (Btulh) Exp 8 Cooling equipment serving Controlled Plant Growth Environments. Equipment cooling efficiency shall be better than WSEC required minimum efficiency by at least 20%. Not eligible: unitary and applied teat pumps. System ID SEER, EER, & IEER Exp 9 Cooling equipment with energy recovery. Spaces served shall have year-round design cooling loads from lights and equipment greater than 5watts per square foot. Energy recovery system shall utilize recovered energy for on-site space heating or preheating of service hot water. Frovide calculations to the code official that demonstrate the amount of recovered energy used for on-site heating purposes is equivalent to the ainual energy that would be saved by the cooling system with air economizer per C4033. System ID Lighting + Equipment Loads (W/sf) DA IKIN Submittal Data Sheet 2.0 Ton Wall Mounted Unit FTXS24LVJURXS24LVJU OUTDOOR UNIT DETAILS'' Power Supply (V/Hz/Ph): 208-230 / 60 / 1 Compressor Type: Inverter Power Supply Connections: 11, L2, Ground Capacity Control Range (%): Min. Circuit Mips MCA (A): 17.50 Airflow Rate (H) (CFM): Max Overcurrent Protection (MOP) (A): 20.00 Gas Pipe Connection (inch): 1,924 5/8 Max Starting Current MSC(A): Liquid Pipe Connection (inch): 1/4 Rated Load Amps RLA(A): 7.1 Dimensions (HxWxD) (in): 30-5/16 x 35-7/16 x 12-5/8 Sound Pressure (H) (dBA): 52 Sound Power Level (dBA): 66 Net Weight (Ib): 159 DIMENSIONAL DRAWING - OUTDOOR UNIT 35-7/16 24-7/16 4 0 4 -CUTS FOR ANCHOR BOLTS m tnN (M12) va co 1.314 14-13/16 7.11a m M Z Q m� DRAIN OUTLET I.D. (15/16 HOSE FOR CONNECTION. BRAND N/ME LABEL MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE = LESS THAN 47.1/4 `////1///////////////1111//1 **///////////////7//// //AV w w w 0 a co c) 1-15/16 44///1l///////l///1!/1/1///1! M M GAS STOP VALVE TERMINAL STRIP OUTDOOR AIR NAME PLATE LIQUID STOP VALVE THERMISTOR GROUND TERMINAL l o .r • 1' RXS24LVJU 1.. 4.1/16 GAS PIPE 15/8 SINGLE UNION) LIQUID PIPE (f1/4 SINGLE UNION) 2015 Washington State Energy Code Compliance Forms for. Commercial, R2 and R3 over 3 stories and all R1 Economizer Exceptions con TECH-ECON+C 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Date 1/1/2015 Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS, CONTINUED Exp 10 Cooling equipment for dedicated server, electronic equipment or telecom switch moms. Per building limit for this exception is 240,000 Btu/h cooling capacity or 10% of required building air economizer capacity, whichever is greater. Part load control required over 85,000 Btulh. Additional requirements apply. Option a - Cooling equipment efficiency shall be 15% better than the WSEC required minimum efficiency... Option b - Waterside economizer required. Cooling equipment. efficiency shall be 5% better than the WSEC required minimum efficiency. Option c - Waterside economizer required. All cooling equipment is subject to ASHARE Standard 127. System ID Compliance Option Cooling Capacity (Btu/h) AH-1/CU-1 Option a 21,500 Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 240 kBtulh): Alternate Exp 10 Capacity Limit: 21,500. ECONOMIZER EXCEPTIONS -MECHANICAL SYSTEM ALTERATIONS OR REPLACEMENT' C503.4 Pre -approved design alternative to full compliance with air economizer Exp 1 requirement An alternative far mechanical system alterations where existing building constraints make full compliance with air economizer requirement impractical. Provide calculations to the code official that demonstrate the proposed altemate design strategy provides similar energy savings to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID AltStrategy ECONOMIZER EXCEPTIONS - SIMPLE SYSTEMS C503.4 Exp 2 Qualifying small equipment. Per unit limit less than 33,000 Btu/h. Per building limit for this exception is 72,000 Btu/h cooling capacity or 5% of required building air economizer capacity, whichever is greater. Cooling equipment efficiency shall be 15% better than WSEC required minimum efficiency. Not eligible: non -unitary equipment, unitary equipment installed outdoors or in mech room adjacent to outdoors, equipment installed during new construction, shell -and -core construction, or initial tenant improvement. System ID Cooling Capacity (Btu/b) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 72,000 Btulh): Alternate C503.4 Exp 2 Capacity Limit: C503.4 Equipment that provides hydmnic chilled water for chilled water terminal Exp 3 units. Equipment part load cooling efficiency (IPLV) shall be better than WSEC required minimum efficiency by at least 25%. Per building limit for this exception is 480,000 Btu/h cooling capacity or 20% of required building air economizer capacity, whichever is greater. Chilled water terminal units serving Group R occupancies are not included in the .. building capacity total. System ID Cooling Capacity (Bluth) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 480,000 Btu/h): Alternate C503.4 Exp 3 Capacity Limit Table Compliance Options for alteration or replacement of existing C503.4 mechanical cooling equipment per Table C503.4. Refer to table and all applicable table footnotes for full requirements. Applies to the following retrofit conditions: Option a - Any new or replacement equipment Option b - Replacement equipment of same type with same or smaller cooling output capacity. Option c - Replacement equipment of same type with large cooling output capacity. Option d - New equipment added to existing system or replacement equipment that is different than existing being replaced. ' System ID Equipment Type Compliance Path 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical` Fan System Power Allowance MECH-FANSYS-SUM Ccmpliance Forms for Commercial Buildings induding R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: WELLS FARGO BANK LOCKBOX Date 1/1/2015 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. System or Primary Supply Fan ID Speed Control (Note 1) Description (Note 2) • System Total Nameplate HP ,(Note 3) . Fan Power Calculation Required (Note 4) AH -1 VAV AIR HANDLER 0.064 No CU -1 CONDENSING UNIT 0.088 No 'cal 17 00 5 Note 1- Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per 0403.2.11.1 Exception 1. Sing e zone VAV systems shall comply as CV. Note 2 - Describe system type and list all fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. Include all supply, returnfrefief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes), or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No) MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp_ Select (Add Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E32 of the added form. REVIEWED FOR CODE COMPLIANCE APPROVED 1 JUN ID 2017 tx„ City 0? Tut la • BUILI I E 11,itS4ON RECEIVED CITY OF TUKWILA JUN 05 2017 PERMIT CENTER (- REVISIONS v z COMFORT F. 253.736.6598 0 O ct z m �p o rn � d Q � J J coLIJ Y DATE: SCALE DRAWNI - CHECKED: 1 00-000