Loading...
HomeMy WebLinkAboutPermit M17-0086 - FAMILY FUN CENTER - ROOFTOP A/C UNITFAMILY FUN CENTER 7300 FUN CENTER WAY EXPIRED 12/27/17 M17-0086 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2423049063 7300 FUN CENTER WAY FAMILY FUN CENTER MECHANICAL PERMIT Permit Number: M17-0086 Issue Date: 6/30/2017 Permit Expires On: 12/27/2017 Owner: Name: Address: FAMILY FUN CENTERS TUKWILA 7300 FUN CENTER WAY, TUKWILA, WA, 98188 Contact Person: Name: JEREMY MOELLER Address: PO BOX 3205 , KIRKLAND, WA, 98083 Contractor: Name: C F M HEATING AND COOLING INC Address: PO BOX 3205 , KIRKLAND, WA, 98083 License No: CFMHEHC969CD Lender: Name: Address: Phone: (425) 821-1293 Phone: (425) 821-1293 Expiration Date: 2/4/2018 DESCRIPTION OF WORK: REPLACE AN EXISTING ROOFTOP A/C UNIT WITH A NEW ROOFTOP A/C UNIT. NEW UNIT WILL SIT ON EXISTING CURB AND CONNECT TO EXISTING SUPPLY AND RETURN DUCTWORK. NEW A/C UNIT WILL RECONNECT TO EXISTING GAS LINE. OLD UNIT WEIGHJS 1,305 LBS. NEW UNIT WEIGHS 1,277 LBS. Valuation of Work: $14,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $384.06 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: {II1LIIk, P I Tf l Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: cT.i,i4y RIR Pp.,' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: ( `3'o'L ) PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH-IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Conununity Development Department Permit Center 6300.Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. ( 63910 Project No. Date Application Accepted: jp IS'( 7 Date Application Expires: (For ofce'use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 73000 Fi A CeA1ef Way Tenant Name: ! GIA�i 1y Fun Ce''ieir King Co Assessor's Tax No.: 4423 O'15 06 3 Suite Number: NA Floor: 6"a� PROPERTY OWNERf Name: rQth; �kl dun CCS, Kers T()kw< i Address: 7300 Fun lin e t 1Trx /ditty City: f _ otut `0. State: LA Zip:781 43 CONTACT PERSON — person receiving all project communication Name: �eAe of IA ot,ue Aot,ue ✓' Address: F o Cox 3205 p City: V t oan j' State: zip: 1`u0f3 I Phone:Ily2, _ 621. X243 Fax: ail_ (3y 3 1 Email: �F�2tM4ty CFM- VkVitCR_cOP New Tenant: ❑ Yes ®..No MECHANICAL CONTRACTOR: INFORMATION Company Name: C €M Ne��; 0 Q _ 1 , no (� JJ Address: P QOK 3205 City: I<.I al'Id4IJ State: 6� 7_ip:.80g3 (( Phone: G125't�-'1e t _1713 Fax: 6z -ti_ (5c13 Contr Reg No.: C FMNE \Ae`j Exp Date: H1GJ oZ py/ f6 Tukwila Business License No.: Valuation of project (contractor's bid price): S Describe the scope of work in detail: �e1/40tUe an eJ�ig{i � cobc4cp AC tr ew rook top AC, on i -f . N2w 06.t:I\ 5t- an e)65t'.oj Coo Curb ctncl count-{ +o ex;bigD ,5upP1H and fC41ri duc4tuorL t\jew Ac L'A,-i w‘t l\ re conM4 �o ex',bi"r jr Jas \fie O\� c wei5ins t, 305 1o6 _ OM) ENO wet6h5 ►1277 'ii 000 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric..... ❑ Gas Other: 1I `Applical ionAlorms-Applicn:imis 1)n Line'21110 Applian inns'•Atechanical Permit Application Revised 1-4-16.docx Revised: J:uwary 2010 hh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace>100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 1 <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) incinerator — comnt/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/I,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Proper y Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) ' 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES 1 Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT t HAVE READ AND EXAMINED THiS APPLICATION AND KNOW THE SAME TO 13E TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND i AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 'N R OR AUTHORIZED AGENT: Signature: Date: 06 (5-11 Print Name: CJe►"etly AyScy- Mailing Address: Po, bx. 32o5KwkiciQf Vob5 Il:`,Applienl ions \Forms-Appltont ions On Line \21116 Applications\Mechanical Permit Application Revised I-4-16.docx Rcvisul: January 2016 hh Day Telephone: State Zip City Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY °PermitTRAK PAID $384.06 M17-0086 Address: 7300 FUN CENTER WAY Apn: 2423049063 $384.06 MECHANICAL $369.29 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $262.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $73.86 TECHNOLOGY FEE $14.77 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.77 TOTAL FEES PAID BY RECEIPT: R11727 $384.06 • Date Paid: Thursday, June 15, 2017 Paid By: CFM HEATING AND COOLING INC Pay Method: CHECK 10293 Printed: Thursday, June 15, 2017 3:30 PM 1 of 1 CANWSYSTEMS 11/2/2017 City of Tukwila Department of Community Development JEREMY MOELLER PO BOX 3205 KIRKLAND, WA 98083 RE: Permit No. M17-0086 FAMILY FUN CENTER 7300 FUN CENTER WAY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/27/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it -is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/27/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M17-0086 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0086 DATE: 06/15/17 PROJECT NAME: FAMILY FUN CENTER SITE ADDRESS: 7300 FUN CENTER WAY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: f\-.1 frwo 441 Building Division Public Works ❑ PMM Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/20/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 07/18/17 ❑ Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Pernat Center Use Only CORRECTION LETTER MAILED -�_ Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 C F M HEATING AND COOLING TNC Home Espanol Contact. Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 Ai A -Z Index Help My L&1 Workplace Rights Trades & Licensing C F M HEATING AND COOLING INC Owner or tradesperson Principals CLANCY, SHAUN P, PRESIDENT Doing business as C F M HEATING AND COOLING INC WA UBI No. 602 361 244 PO BOX 3205 KIRKLAND, WA 98083 425-821-1293 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. CFMHEHC969CD Effective — expiration 02/04/2004— 02/04/2018 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 798903C $12,000.00 Received by L&I Effective date 12/17/2008 02/04/2009 Expiration date Until Canceled Insurance AMERICAN FIRE & CASUALTY CO $1,000,000.00 Policy no. BKA54333410 Received by L&I Effective date 01/11/2017 02/04/2011 Expiration date 02/04/2018 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602361244&LIC=CFMHEHC969CD&SAW= 6/29/2017 C F M HEATING AND COOLING JNC Do you know if the t usiness has employees? If s ify the business is up-to-date on workers' comp premiu L&I Account ID 061,078-00 Doing business as CFM HEATING AND COOLING INC Estimated workers reported Quarter 1 of Year 2017 "21 to 30 Workers" L&I account contact Employer Services Help Line — 360-902-4817 Account is current. Workplace t,afety and health No inspections during the previous 6 year period. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni :..va.gov/verify/Detail.aspx?UBI=602361244&LIC=CFMHEHC969CD&SAW= 6/29/2017 ABBREVIATIONS AC AD AFC AFF AHU AL BDD BFC BHP BI BOD BTU BTUH CFM CO CV CW CRD AIR CONDITIONING ACCESS DOOR ABOVE FINISHED CEILING ABOVE FINISHED FLOOR AIR HANDLING UNIT ALUMINIUM BACK DRAFT DAMPER BELOW FINISHED CEILING BRAKE HORSE POWER BACKWARD INCLINED BOTTOM OF DUCT BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR CUBIC FEET PER MINUTE CLEAN OUT CONSTANT VOLUME COLD WATER CEILING RADIATION DAMPER DIA DIAMETER DIM DIMENSION DMPR DAMPER DN DOWN DP DIFFERENTIAL PRESSURE DWG DRAWING EX EXISTING EAT ENTERING AIR TEMPERATURE EF EXHAUST FAN EFF EFFICIENT, EFFICIENCY EG EXHAUST GRILLE ELEC ELECTRICAL FG FLOOR GRILL FD FIRE DAMPER F FURNACE FPM FEET PER MINUTE FSK FOIL SKRIM KRAFT LINER (SPUNSTRAND) FT FEET, FOOT GR HP HR HTG HVAC HW ID IN INFO INSUL JAN KW KWH LAT LF LVG MA MBH MAT MAX MECH MFG MED MIN MISC NA NTS PD PERF PF PH QTY RA REQD RET RGM SA SCHED SD SF SFD S.I.O SHT SP PEC SR SS STAT TEMP TK TEMP THRU TSTAT TYP UL UV UMC UP UBC V VAC VDC VD VAC VAV VEL VOL GAS GRILLE HORSE POWER HOUR HEATING HEATING, VENTTALTION AND AIR CONDTIONING HOT WATER INSIDE DIMENSION INCH, INCHES INFORMATION INSULATE, INSULATION JANITOR KILOWATT KILOWATT HOUR LEAVING AIR TEMPERATURE LINEAL FEET LEAVING MIXED AIR THOUSAND BRITISH THERMAL UNITS PER HOUR MIXED AIR TEMPERATURE MAXIMUM MECHANICAL MANUFACTURER MEDIUM MINIMUM, MINUTE MISCELLANEOUS NORTH NOT APPLICABLE NOT TO SCALE PRESSURE DROP PERFORATED PRE FILTER PHASE QUANTITY RETURN AIR REQUIRED RETURN REVOLUTIONS PER MINUTE RETURN GRILLE SUPPLY AIR SCHEDULE SMOKE DETECTOR SUPPLY FAN SMOKE/FIRE DAMPER SUPPLIED & INSTALLED BY OWNER/ (OTHER) SHEET STATIC PRESSURE SPECIFICATION SUPPLY REGISTER STAINLESS STEEL THERMOSTAT TEMPERATURE TOE KICK TEMPORARY THROUGH THERMOSTAT TYPICAL UNDERWRITER'S LABORITORY UNIT VENTILATOR UNIFORM MECHANICAL CODE UNIFORM PLUMBING CODE UNIFORM BUIDUNG CODE VOLT VOLTS AC VOLTS DC VOLUME DAMPER VACCUUM VARIABLE AIR VOLUME VELOCITY VOLUME MECHANICAL SPECIFICATION GENERAL SCOPE THE INTENT OF THE SPECIFICATION AND NE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL MECHANICAL SYSTEM. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO COMPLETE THE MECHANICAL WORK. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW OFFSETS WHICH MAY BE REQUIRED. SITE EXAMINATION THE MECHANICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, DUCTWORK, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE MECHANICAL WORK. PACKAGED ROOFTOP AC UNIT SCHEDULE MARK MAKE MODEL CFM SP. COOLING HEATING ELECTRICAL WEIGHT ECONO TOTAL SENS IEER INPUT OUTPUT AFUE% DATA FUSE M.C.A. AC -1 CARRIER 48TCDD14A3A5-0A0G0 5000 .50" 23.28 18.04 12.2 IEER 120.0 98.0 82.0 208-3-60 80 67 1277 LBS. YES STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF HVAC NOTES: ARL, ASME, ASTM, UL, NEMA, ANSO, SMACNA, ASHRAE, NFPA, AS APPLICABLE 1. AC -1 IS TO BE EQUIPPED WITH ECONOMIZER TO EACH INDIVIDUAL UNIT OR ASSEMBLY. _2- C--ISPL UNIT.SITN E OXISTING ROOF - CURB AND CONNECT TO EXISTING SUPPLY AND RETURN AIR DUCTWORK, NO INTERIOR CHANGES CODES S a , ¢t ►`r ec iore ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO THE OWNER. PERMITS AND FEES THE MECHANICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE MECHANICAL WORK. WARRANTY THE MECHANICAL CONTRACTOR SHALL UNCONDITIONIALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY OWNER, AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND SHALL RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. DUCTWORK AND ACCESSORIES SHEET METAL DUCTWORK ALL DUCTWORK TO BE RIGID SHEET METAL CONSTRUCTED FROM GALVANIZED SHEET STEEL IN ACCORDANCE WITH SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS. ALL EXPOSED DUCTWORK TO BE ROUND, SPIRAL, LOCK SEAM TYPE. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (8% LEAKAGE) AND NOISELESS (NO OBJECTIONABLE NOISE) SYSTEMS CAPABLE OF PERFORMING EACH INDICATED SERVICE. FURNISH ALL DAMPERS, TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING SYSTEM. NO VARIATION OF DUCT CONFIGURATION OR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER. DUCT SEALANT SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A NON -HARDENING, NON -MIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR SEALING JOINTS AND SEAMS IN SHEET METAL DUCTWORK. COVER ALL FIELD JOINTS, JOINTS AROUND SPIN -IN FITTINGS, AND FASTENING SCREWS WITH MASTIC. SUPPORTS: PROVIDE HOT -DIPPED GALVANIZED STEEL, FASTENERS, ANCHORS, RODS, STRAPS, TRIM, AND ANGLES FOR SUPPORT OF DUCTWORK. DAMPERS PROVIDE OPPOSED -BLADE, MULTI -LEAF VOLUME CONTROL DAMPERS WHERE INDICATED ON DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN, AND EXHAUST DUCTS WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIED UL LISTED FIRE DAMPERS WHERE REQUIRED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE CONVEINIENTLY LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE DAMPERS. THERMAL INSULATION PROVIDE EXTERNAL THERMAL INSULATION WIN AN INTEGRAL VAPOR BARRIER FACING OF SUFFICIENT THICKNESS TO MEET LOCAL ENERGY CODE REQUIREMENTS. PROVIDE INSULATION ON EXHAUST AND OUTSIDE AIR DUCTS, AND ON CONCEALED PORTIONS OF SUPPLY AND RETURN AIR DUCTS. DO NOT INSULATE EXPOSED DUCTWORK AND PORTIONS OF DUCTWORK THAT ARE INTERNALLY LINED. THERMAL INSULATION TO COMPLY WITH AN NFPA FLAME SPREAD OF 25 OR LESS, AND SMOKE DEVELOPED NO GREATER THAN 50. ACCOUSTICAL DUCT LINER: UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE 1" GLASS FIBER ACCOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK WITHIN 10 FEET OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS. INCREASE DUCT SIZE INDICATED ON PLANS 2" IN EACH DIMENSION TO ACCOMODATE LINER. TESTING, ADJUSTING, BALANCING MECHANICAL CONTRACTOR OR AN INDEPENDENT NEBB • OR AABE CERTIFIED AIR BALANCE CONTRACTOR SHALL ACCURATELY BALANCE THE AIR SYSTEMS TO PROVIDE AIR QUANTITIED INDICATED ON THE DRAWINGS AND IN THIS SPECIFICATION. OPERATE AUTOMATIC CONTROLS SYSTEM AND VERIFY SET POINTS DURING BALANCING. SUBMIT TWO (2) COPIES OF THE BALANCE REPORT TO THE ENGINEER FOR APPROVAL. INCLUDE A COPY OF THE BALANCE REPORT AS APPROVED BY THE ENGINEER WITH APPLICATION FOR FINAL CONTRACT PAYMENT. 2015 INTERNATIONAL ENERGY CODE NOTES WITH WASHINGTON STATE AMENDMENTS: 1. ALL SINGLE ZONE AC UNITS DO NOT EXCEED CAPACITY LIMITS AND DO NOT HAVE ACTIVE HUMIDIFICATION OR SIMULTANEOUS HEATING AND COOLING PER SECTION C403.34 2. AC -1 REQUIRES ECONOMIZER PER SECTION 0403.3.1 3. AC -1 IS TO BE INSTALLED WITH MODULATING ECONOMIZER CAPABLE OF 100% OSA 4. AC -1 REQUIRES ECONOMIZER CONTROLS PER SECTION 0403.4.1 5. CONTROLS FOR ECONOMIZER UNITS WILL BE INSTALLED TO CONTROL BUILDING HEATING USAGE DURING NORMAL OPERATION PER SECTION 0403.4.1.4 6. AC -1 SHALL HAVE THERMOSTATIC CONTROLS PER SECTION 0403.3.4.1 7. AC -1 SHALL INCLUDE MICROPROCESSOR CONTROLS THAT MINIMIZE SUPPLEMENTAL HEAT USAGE DURING START UP AND DEFROST PER SECTION 0403.2.4.1.1. UNIT CURB A/C UNIT CURB INSULATION A/C UNIT RAIL SECURE AtC UNIT TO CURB W/ /8" X 4 LONG BOLT, 2 EA SIDE OF UNIT OR #10 SHEET METAL SCREWS ® 24" O.C. ETAL FLASHING ROOFING MATERIAL CURB LEVELING FRAME ROOF DECK TYPICAL A/C UNIT MOUNTING SCALE: NONE COQ`= Perm5t N a M ri—oOC6Co Pan reVi " a i3 Subject to errors and omissions. Approval c? c3i o coca ments does not authorize the violation of Lily adopted code or ordinance. Begirt of approved Fi,Jid Copy and conditions is acknowledged: By: Date: " 060-3D-(-7 City of Tukwila BUILDING DIVISION REVISIONS No changes she!! Fro made to the scope of work \+Without prior approval of T uki.v+la Building Division. 1'777: 7: : 17.,1 i•..:;.:! ro as r:.-/ r's,n Submit! i SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical gi Electrical Plumbing Grans as Piping cf Tukwila Btifr' ;r, n!VISION DRAWING SYMBOLS O NORTH ARROW SECTION IDENTIFICATION SHEET IDENTIFICATION COLUMN GRID SYMBOLS GENERAL MECHANICAL NOTES NUMBER IDENTIFICATION FLAG MECHANICAL NOTES NUMBER IDENTIFICATION MECHANICAL LEGEND SYMBOL DESCRIPTION IN ORMAI I LI T UNF OUND NEW WORK (HEAVY UNE) ORLD VICEaTelATEDQUIPMENT ITEM % BE SIELEA DEMOUS K POINT OF NEW CONNECTION EXHAUSAN SNONSIGNATI(NV ROOM/ZONE THERMOSTAT 2NDTFIGURE SIDE INSIi0 1111 FLEXIBLE CONNECTION VOLUME DAMPER //' t 45' TAKE -OFF ? 2 ,9i • FCjaANGULAR TAKE -OFF W1TH tww., FLEXIBLE DUCT SFD AFD 8 TERMINALS: TYP2 CRD MOTORIZED DAMPER COMBINATION SMOKE/FIRE DAMPER FIRE DAMPER RADODPE GRILLE IA11N A C LgUNG DIFFUSER, TYPE 1 BALAN <TO 350 CFM 2R4E1URN EGRILLE, TYPE 1 BALANCE 1 350 CFM TRANSFER GRILL, TYPE 1 24x12 NECK BALANCE TO 350 CFM TYPICAL OF 2 CEILING DIFFUSER N44- CEILING RETURN GRILLE CEIUNG EXHAUST GRILLE ---- RL RS REFRIGERANT LIQUID LINE REFRIGERANT SUCTION LINE CONDENSATE PIPING SHEET INDEX REVISION m 0 Q z 0 JOB NUMBER 0 JEREMY MOELLER ■ cC 00 w 1- HVAC SCHEDULES M0.1 HVAC SCHEDULES RECEIVED M1.0 HVAC ROOF PLAN CITY OF TUKWILA JUN 15 2017 PERMIT CENTER OFS27 RE COD It...t.n.,4"'"..'=.4,.`t,:.. , '2,-Z:?"'»tirefft,' • 0 8 SET DATE: 06-13-17 BU oz 0 212 ,s8 gg' z gW oZ a aux §2,,q 11 ,E° WED F OMPLIANCE ROVED 2 2 2017 f Tukwila G DIVISION SHEET NUMBER 0 N co E zo c U UJ O) U U Z c ' Y r N .rod Mo.7 CONTRACTOR'S LICENSE CFMHEHC969CD REPLACE EXISTIN AC UNIT WITH NEW UNIT. UNIT IS A CARRIER MODEL #48TJD014---531 GA, 12.5 TON (5000 CFM), 208-3-60 ELECTRICAL, 120,000 BTU'S HEATING, WEIGHING 1,305 LBS. NEW UNIT IS A CARRIER MODEL #48TCR 14A3A5-0A0AG0, 12.5 TON (5000 CFM), 208-3-60 ELECTRICAL, 120,00 BTU'S HEATING, WEIGHING 1,277 LBS WITH ECONOMIZER AND 2 STAGE CO . ING WITH VFD EXISTING ROOFTOP AC UNIT TYPICAL OF ALL HVAC ROOF PLAN SCALE:1 /8"=1'0" 27 2017, M17 -00$b RECEIVED CITY OF TUKWILA JUN 15 2017 SET DATE: Q6-13-17 PER CENTER REVISION JOB NUMBER CC M Z LI W W F— (3) EQ EVIE DE CO APPROVED JUN 2 2 2017 DING DIVISIo SHEET NUMBER M1.0 CONTRACTOR'S LICENSE CFMHEHC969CD