Loading...
HomeMy WebLinkAboutPermit M17-0096 - SAFARI - BATHROOM EXHAUST VENTSAFARI 2867 SOUTHCENTER MALL MI 7-0096 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 9202470010 2867 SOUTHCENTER MALL Project Name: SAFARI Permit Number: Issue Date: Permit Expires On: M17-0096 8/30/2017 2/26/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 GLORIA CHIEN 1420 NW GILMAN BLVD #23463 , ISSAQUAH, WA, 98027 J E M CONSTRUCTION INC 29506 8TH AVE S , ROY, WA, 98580 JEMCOI*033DD Phone: (206) 335-4199 Phone: (253) 843-2765 Expiration Date: 5/15/2019 DESCRIPTION OF WORK: ADDING BATHROOM EXHAUST VENT. ADJUSTING MINIMUM OUTSIDE AIR FOR VENTILATION. Valuation of Work: $4,500.00 Type of Work: REPLACEMENT Fuel type: Fees Collected: $264.12 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name U -n Date: 8/3(3//7 /7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 2: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 3: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 4: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: ***MECHANICAL PERMIT CONDITIONS*** 7: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 8: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKV,, A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project. No. ffi Date Application Accepted: Date Application Expires: (For gffice use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: q 20 2 /- - 0 0 % 0 Site Address: Z 6 7' So 14+1114+11e�,w�>r / 11 , L4 fro act W/rl gl Sgite Number: Floor: 2 - Tenant Tenant Name: PROPERTY OWNER Name: Wes f eG,( SoN+hCerrter. Address: (233 SoialtLla e✓ Parkway City: TIAtAiibtState: 1NA Zip:it 1$a CONTACT PERSON — person receiving all project communication Name: �IoriA Glti2h , rs Pest./", Address: ) (t20 Ai W ci iwt0t." g b/d . it 234-3 City: i rssapa State: wA Zip: pia 0 27 Phone: lP,� o 6 3 3 et p Fax: Email: gloriac@ v -s--desiakc . tow, New Tenant: gf Yes ❑.. No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Z{- S7-,5 0 Describe the scope of work in detail: Ad4.146.1 120cHn Yborin a ach a V e k1 . A dj to dM9 M/11).1 ►+M uM, o t&t rte t 4-o r VeA,- f"Art t . u vA C. sys-te. -Eo rem/1,41A a S 1 f. Use: Residential: New Commercial: New Fuel Type: Electric ❑ Replacement Replacement Gas ❑ o Other: N l H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 *Daytim District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) ' 70 dB(A) A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR UTHORIZED AGENT: Signature: Date: 00— y/2o / �- Print Name: C h t 145.61 Day Telephone: Mailing Address: 6 2- 7 / L i 3i, A- v.V e -Alf- ASIC e City H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh 206 2Z 43S Ain qg a s� State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT QUANTITY ( PAID $2,289.25 D17-0177 Address: 2877 SOUTHCENTER MALL Apn: 9202470010 $1,896.53 DEVELOPMENT $1,806.43 PERMIT FEE R000.322.100.00.00 0.00 $1,801.93 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $90.10 TECHNOLOGY FEE R000.322.900.04.00 0.00 $90.10 M17-0096 Address: 2867 SOUTHCENTER MALL Apn: 9202470010 $213.33 MECHANICAL $203.17 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $170.02 TECHNOLOGY FEE $10.16 TECHNOLOGY FEE I R000.322.900.04.00 I 0.00 $10.16 PG17-0080 Address: 2867 SOUTHCENTER MALL Apn: 9202470010 $179.39 PLUMBING $170.85 PERMIT FEE R000.322.100.00.00 0.00 $137.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $8.54 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12230 R000.322.900.04.00 0.00 $8.54 $2,289.25 Date Paid: Wednesday, August 30, 2017 Paid By: JEM CONSTRUCTION Pay Method: CHECK 15277 Printed: Wednesday, August 30, 2017 9:36 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY I PAID $1,264.75 D17-0177 Address: 2867 SOUTHCENTER MALL Apn: 9202470010 $1,171.25 DEVELOPMENT $1,171.25 PLAN CHECK FEE 1 R000.345.830.00.00 I 0.00 $1,171.25 M17-0096 Address: 2867 SOUTHCENTER MALL Apn: 9202470010 $50.79 MECHANICAL $50.79 PLAN CHECK FEE R000.322.102.00.00 0.00 I $50.79 PG17-0080 Address: 2867 SOUTHCENTER MALL Apn: 9202470010 $42.71 PLUMBING $42.71 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R11832 R000.322.103.00.00 0.00 $42.71 $1,264.75 Date Paid: Thursday, June 29, 2017 Paid By: RAINIER ACTIVE LLC Pay Method: CHECK 1007 Printed: Thursday, June 29, 2017 1:48 PM 1 of 1 CIISYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:q Type` of Inspection: firm-L_ Address: 'Z -81e'7 SC't}71CJ4firg 1141414— Date Called: Special Instructions: Date Wanted: /6s'516 -i 7 a.m. P.m. Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: _ pm1-t McCi, „009-L_ Inspector: 215 Date: /o —33-1 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0096 DATE: 06/30/17 PROJECT NAME: SAFARI SITE ADDRESS: 2867 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A-3 AlAi C 7 11111 Building Division Public Works ❑ \I -r Ay -to-17 Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 07/04/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 4110 08/01/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 J E M CONSTRUCTION INC Home. Espaiiol Contact Search L&I Page 1 of 2 A -Z Index Help My L&1 Safety & Health Claims & Insurance Workplace Rights Washington State Department of 40 Labor & Industries J E M CONSTRUCTION INC Owner or tradesperson Principals MILLER, JAMES E, PRESIDENT Doing business as J E M CONSTRUCTION INC WA UBI No. 601 770 782 29506 8TH AVE S ROY, WA 98580 253-843-2765 PIERCE County Business type Corporation Governing persons JAMES E MILLER LORI K MILLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. JEMCOI*033DD Effective — expiration 03/04/1997— 05/15/2019 Bond ................. CBIC Bond account no. SA7695 $12,000.00 Received by L&I Effective date 03/19/2002 03/01/2002 Expiration date Until Canceled Insurnace ............. -..... .... American States Insurance Co Policy no. 01C12205496 $1,000,000.00 Received by L&I Effective date 03/23/2017 04/16/2015 Expiration date 04/16/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bondor savings .. ........ .... No lawsuits against the bond or savings accounts during the previous 6 year period. Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601770782&LIC=JEMCOI*033DD&SAW= 8/30/2017 J E M CONSTRUCTION INC L&I Tax debts No L&I tax debts are recorded for this contra.__. license during the previous 6 year period, but some L may be recorded by other agencies. License Violations ... _................................................ No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 968,907-00 ................................. Doing business as J E M CONSTRUCTION INC Estimated workers reported Quarter 2 of Year 2017 "4 to 6 Workers" L&I account contact T2 / SUSAN BETTS (360)902-4828 - Email: BETT235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 CI Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601770782&LIC=JEMCOI*033DD&SAW= 8/30/2017 GENERAL NOTES 1) COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE MOST CURRENT BUILDING, MECHANICAL, ENERGY, PLUMBING, F1RE AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. 2) ALL AIR-CONDITIONING UNITS WITHOUT INTERNAL TRAP SHALL HAVE A P -TRAP FOR THE CONDENSATE PAN WITH PLUG TEES FOR CLEANING AND CONDENSATE PIPES SHALL BE DISCHARGED TO EXISTING CONDENSATE WASTE PIPING. VERIFY SIZE AND LOCATION AT SITE. 3) MECHANICAL CONTRACTOR SHALL COORDINATE DIFFUSER LOCATIONS AND DUCT ROUTING CLEARANCES WITH THE STRUCTURAL, REFLECTED CEIUNG AND LIGHTING PLANS. 4) ALL F1RE RATED STRUCTURE SHALL BE F1RE DAMPERED. VERIFY WITH THE ARCHITECTURAL AND INSTALL PER THE LOCAL JURISDICTIONS. 5) ALL AIR DISTRIBUTION OUTLETS SHALL HAVE VOLUME CONTROL DEVICES. 6) ALL VOLUME DAMPERS IN NON -ACCESSIBLE CEILINGS SHALL HAVE A CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION ("YOUNG" REGULATIONS OR EQUAL). EXACT LOCATION OF CONTROL DEVICES VISIBLE IN FINISHED SPACES SHALL BE COORDINATED WITH THE ARCHITECT. 7) ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH -ROUND OR SQUARE WITH TURNING VANES. 8) MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF PIPING AND DUCTWORK AND PENETRATIONS WITH THE STRUCTURE. 9) MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 6' OR AS SHOWN ON DRAWINGS. 10) ALL DUCTWORK, EQUIPMENT AND PIPING SHALL BE SEISMICALLY SUPPORTED PER SMACNA AND LOCAL REGULATIONS. 11) ALL MECHANICAL EQUIPMENT SHALL CONFORM TO SMACNA AND LOCAL REGULATIONS FOR SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). 12) ALL EQUIPMENT AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE ACCESS DOORS. 13) TOTAL SYSTEM SHALL BE WARRANTED FOR ONE YEAR; STARTING FROM THE TIME OF OWNER/ENGINEER'S FINAL ACCEPTANCE. 14) HVAC NOTES: A) PROVIDE FLEXIBLE CONNECTION IN ALL DUCTS CONNECTING TO AIR MOVING EQUIPMENT AS CLOSE TO FAN AS POSSIBLE. FLEXIBLE CONNECTION SHALL CONSIST OF 6" OR MORE OF AIR TIGHT, FIREPROOF FLEXIBLE NEOPRENE COATED WOVEN FIBROUS GLASS MATERIAL. VENT FABRICS, INC. OR APPROVED EQUAL B) ALL DUCTWORK SHALL BE SHEET METAL SOUND UNE RECTANGULAR SUPPLY AND RETURN DUCTS WITHIN 10 FEET FROM THE UNIT OPENINGS. C) D) E) F) PROVIDE LOCKABLE VOLUME DAMPERS IN ALL AIR DISTRIBUTION OUTLETS. DUCT HANGERS, SUPPORTS AND METHODS OF INSTALLATION SHALL CONFORM TO ASHRAE AND SMACNA RECOMMENDATIONS. DUCT SIZES SHOWN ON PLANS INDICATE INSIDE FREE AREA. ALL DUCTWORK SHALL BE CLASS 1 AIR DUCT AS APPROVED BY U.L-181. 15) THE CONTRACTOR SHALL NOT OPERATE THE EQUIPMENT FOR TEMPORARY HEATING OR VENTILATION DURING THE CONSTRUCTION. (ALL EQUIPMENT SHALL RUN FOR TESTING AND BALANCING PURPOSES ONLY). NOTIFY THE ENGINEER 48 HOURS (MINIMUM) IN ADVANCE TO ARRANGE A FINAL FIELD INSPECTION PRIOR TO COVERING UP THE CEIUNG. 16) CONTRACTOR IS TO BRING UP THE DISCREPANCIES AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED FOR OR SHOWN BUT ARE REQUIRED FOR A COMPLETE MECHANICAL SYSTEM AND AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT; AFTER AWARDING THE CONTRACT ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE OWNER'S BENEFICIAL USE SHALL BE FURNISHED AND INSTALLED INCLUDING ALL SUCH DISCREPANCY ITEMS MENTIONED ABOVE, AT NO ADDITIONAL COST TO THE OWNER AND PER LOCAL CODES. MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE STANDARDS WITH THE ARCHITECT/ENGINEER'S APPROVAL 17) ALL EQUIPMENT SUPPUED FOR THESE SPECIFICATIONS SHALL BE FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND TITLE, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. IF IT APPEARS WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE THAT EQUIPMENT DOES NOT MEET THE WARRANTIES ABOVE, THE CONTRACTOR SHALL IMMEDIATELY CORRECT ANY DEFECT AND SHALL RESTORE THE SYSTEM TO THE ORIGINAL SATISFACTORY CONDITIONS AT HIS EXPENSE. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN UEU OF OTHER WARRANTIES, WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY. NO WARRANTY OF MERCHANT ABILITY OF FITNESS FOR PURPOSE SHALL APPLY. (THE WARRANTY SHALL START FROM THE TIME OF ARCHITECT/ENGINEER'S FINAL ACCEPTANCE.) 18) ENTIRE INSTALLATION OF ALL EQUIPMENT, CONTROL, PIPING, DUCTWORK AND RELATED ACCESSORIES SHALL BE PER BASIC OWNERS' STANDARDS. MECHANICAL CONTRACTOR IS TO FAMILIARIZE HIMSELF WITH THESE STANDARDS. 19) MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY THE ROUTING AND INSTALLATION FEASIBILITY OF ALL EQUIPMENT, PIPING AND DUCTWORK PRIOR TO SUBMITTING HIS BID AND INCLUDE IN HIS BID ADDITIONAL PIPING, DUCTWORK, FITTINGS, OFFSETS, ETC. WHICH MIGHT BE REQUIRED FOR A COMPLETE SYSTEM READY FOR OWNER'S BENEFICIAL USE. 20) COORDINATE THE CONSTRUCTION SCHEDULE WITH THE ARCHITECT AND PERFORM ALL REQUIRED WORK IN STRICT ACCORDANCE WITH THE OWNER'S SCHEDULE. 21) MECHANICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND CERTIFICATES REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. 22) ADJUST ALL EQUIPMENT AND PERFORM A COMPLETE AIR -BALANCING AND PUT ALL MECHANICAL SYSTEMS IN OPERATION AND SUBMIT MINIMUM 4 COPIES OF BALANCING REPORTS TO THE OWNER/ARCHITECT. E RGY CODE NOTES: 1) THERMOSTATS SHALL BE A 7 DAY PROGRAMMABLE TYPE WITH A 5 DEGREE DEADBAND AND AUTOMATIC SETBACK CONTROL PER C403.2.4.3.2 & C403.2.4.2 WSEC. 2) HVAC EQUIPMENT SHALL MEET THE MINIMUM ENERGY EFFICIENCY RATINGS PER TABLES C403 WSEC. 3) DUCT INSULATION AND SEALING SHALL MEET WSEC SECTION 403.2.7 REQUIREMENTS. 4) SUPPLY AND RETURN DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO MIN. R-6.ROOFTOP HVAC DUCTWORK SHALL HAVE A WEATHER BARRIER AND INSULATED TO R-8 PER C403.2.7.2 WSEC. 5) SUPPLY AND RETURN DUCTS IN CONDITIONED SPACES SHALL BE INSULATED TO MIN. R-3.3 PER C403.2.7.2 WSEC. 6) PIPING INSULATION SHALL MEET THE REQUIREMENTS OF TABLE 403.2.8 WSEC. 7) OUTSIDE AIR DUCTS SHALL BE INSULATED PER WSECC403.2.7. OUTSIDE AIR DUCTS SHALL HAVE A MOTORIZED DAMPERS OR AUTOMATIC DAMPER FOR ALL OUTSIDE AIR INTAKES 403.2.4.4 WSEC. 8) HVAC SYSTEMS SHALL BE COMMISSIONED PER C408 WSEC. 9) FRACTIONAL HORSEPOWER MOTORS 1 HP AND LESS SHALL MEET THE EFFICIENCIES PER C403.2.10.3. EXHAUST FAN SCHEDULE SYNX1. EF -1 WM TOILET ROOM MAttr.: BROAN KOELI L100 TYPE CEILING MB DIRECT Cffi 109 ESP. ) 0.125" EXXES 0.9 li'RA: €1.1/ WX.TACe 120 PHAM 1 FD FEMAMS (1)(2) (1) SOURCE SPECIFIC FAN SHALL BE AMCA 210 OR HVI 916. (2) CONTROLLED BY LIGHT SWITCH. DESIGN CODES: ALL CODES WITH WASHINGTON STATE AMENDMENTS 2015 WASHINGTON STATE ENERGY CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 UNIFORM PLUMBING CODE 2015 INTERNATIONAL FIRE CODE LEGEND SYNX1. AIESEVIAIXIN DES ON 0/Cs T'STAT/SENSOR THERMOSTAT/SENSOR Zone Population. Number of people in space.* e1 Occupant Density (#/1000sf) __ DUCTWORK W/ TURNING VANE AND FLEX CONN. —, VD VOLUME DAMPER Proposesd Design Outdoor Air Intake Flow Vot/(CFM) -- RIGID DUCT -- FLEXIBLE DUCT 143 -- ROUND SPIN -IN WITH V.D. FD FIRE DAMPER -4 SFD SMOKE FIRE DAMPER -4 ® CFD CEILING RADIATION FIRE DAMPER C* CD ROUND CEIUNG DIFFUSER • CG ROUND CEILING GRILLE 785 >;g CD SQUARE CEIUNG DIFFUSER Offices* VI CG SQUARE CEIUNG GRILLE CD CD CONDENSATE DRAIN UNE 1.00 121.00 41 -- SMOKE DUCT DETECTOR A.F.F. ABOVE FINISHED FLOOR REVISIONS No chances shell be made to the scope of riorl< !"'ith,� ;? prior approval of Tti! Iiia f3u! ding Division. e .ions itAl require a new plan submittal and may include additional plan reviewfees Permit . Y(, f 7-- QO'! Plan review r9prcI.wl is subject to errors and omissions. Approval of con L cilon documents does not authorize the violation of any adopted code or ordinance. Receipt of approved F; id Copy and conditions is acknowledged: LAAA 1 �)/.)I i'7 City of Tukwila BUILDING DIVISION By Date: Minimum Outside Air Ventilation Schedule Ventilation Rate per 2015 IMC 403 (based on ASHRAE Std. 62.1-2010) Equip. Tag Zone Occupancy Category Area (sf) People Outdoor Air Rate (dm/person) Table 403.3 Zone Population. Number of people in space.* Area Outdoor Air Rate (cfm/sf) (Table 403.3) Occupant Density (#/1000sf) Breathing Zone Outdoor Air Flow Vbz/(CFM) Zone Air Distribution Effectiveness Ez (Table 403.3.1.2) Zone Outdoor Air Flow (Voz/(CFM) System Ventilation EfficiencyEv (Table 403.3.2.3.2 Minimum Outdoor Air Intake Flow Vot/(CFM) Proposesd Design Outdoor Air Intake Flow Vot/(CFM) Safari Place Play Area/Vestibule Education 3100 10.0 50 0.12 35 872.00 1.00 872.00 0.90 785 785 Party Room Offices* 350 5.0 20 0.06 5 121.00 1.00 121.00 0.90 109 110 * In some cases occupancy is Tess than maximums as allowed per 403.3 exception, in no case shall the occupancy be Tess than one half per Table 403.3. \1 EXISTING VAY BOX TO REMAIN EXISTING VAV BOX TO REMAIN 6"0 TO EXIS11IIG EXHAUST PROVIDED FOR FUTURE TENANTS WITH B.D.D. VERIFY AT SITE FOR EXACT LOCATION & ROUTING. COORDINATE WITH LANDLORD !SEPARATE PERMIT PEQ''JIRED FOR: 0 Machanical Pglectrical Lre'`numbing was Piping tyi of Tukwila Libt!ILDP:.IG DIVISION G 0 0 0 0 (E) 0 / 0 E) (E) (E) (E) (E) (E) NOTE: EXISTINi HVAC SYSTEM TO REMAIN. VERIFY T -HC Mf -UM OUTSIDE�A R- PER SCHEDULE ON THIS- SHEET AND ° o FOR "CO2" SENSOR. VERIFY AT SITE AND WITH LANDL–OR-D—Sc PER LOCAL JURISDICTION (E) (E) (FMB 2 (E) 777 (E) + + + ";++ + _ EXISTING JO JREMAIN', co 0 (E) NEW- ` 16x16 LOUVER 0 R (E) (E) 1 r (E) - (r) to (E) 0 o F. E. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 11 2011 City of Tukwila BUILDING DIVISION CO2 MONITOR FOR DEMAND VENTILATION TO CONTROL MINIMUM OUTSIDE AIR PER W.S.E.0 VERIFY EXACT LOCATION & COORDINATE WITH LANDLORD FOR HVAC UNIT MODIFCA11ON c>^lv GI `` OF TUKWILA JUN 2 9 2017 PERMIT CENTER COORDINATE MTH G.C. TO STOP WALL BELOW CEILING FLOOR PLAN - HVAC SCALE= 1/4'4-0' EXISTING TRANSFORMER TO BE VENTILATED NORTH ABOSSEIN ENGINEERING L.L.0 MECHANICAL - ELECTRICAL CIVIL - LEED - STRUCTURAL FIRE PROTECTION 2100 112TH AVE. NE BELT.F,VUE, WA 98004 OFFICE: (425) 462-9441 FAX: (425) 462-9451 EMAIL: CService@abossein.com WEBSITE: www.abos 1'in.com 2867 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS: NO. DESCRIPTION 0 1 z 0 0 w PERMIT SET 6/28/17 JOB NO.: 217077 DATE: 06/28/2017 1 OF 2 0 SPECIFICATIONS EVISIONS: 0. DESCRIPTION PERMIT SET 6/28/17 HVAC SPECIFICATIONS - DIVISION #23 PART 100 GENERAL 1.01 LOCAL CONDITIONS: VISIT AND INSPECT THE PREMISES TO ASCERTAIN THE EXISTING CONDITIONS BEFORE SUBMITTING A BID. NO EXTRA PAYMENT SHALL BE ALLOWED FOR THE LACK OF KNOWLEDGE OF THESE CONDITIONS. 1.02 CODES: STRICTLY COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS. IMC - MECHANICAL CODE IPC - PLUMBING CODE IFGC - FUEL GAS CODE 1.03 STANDARDS: THE FOLLOWING PUBLICATIONS (LATEST EDITION) FORM A PART OF THESE REQUIREMENTS TO THE EXTENT INDICATED BY THE REFERENCES THERETO: SHEET METAL AND AIR CONDITIONING CONTRACTOR NATIONAL ASSOCIATION (SMACNA) LATEST "HVAC DUCT CONSTRUCTION STANDARDS" MANUAL 1.04 PLANS AND SPECIFICATIONS: THE MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN CHARACTER INTENDED TO COVEY THE SCOPE OF WORK AND INDICATE THE GENERAL ARRANGEMENT OF EQUIPMENT, DUCTS, PIPING, ETC., AND APPROXIMATE SIZES AND LOCATIONS OF EQUIPMENT AND OUTLETS. DETERMINE THE EXACT LOCATION OF THE ELEMENTS OF THE SYSTEM FROM THE STRUCTURE AND FROM THE EQUIPMENT, NOT FROM THE DRAWINGS. DO NOT SCALE DRAWINGS FOR MEASUREMENTS NOR USE AS SHOP DRAWINGS. 1.05 PROVIDE ALL ITEMS, EQUIPMENT, MATERIALS, OPERATIONS, OR METHODS LISTED, MENTIONED OR SCHEDULED ON THE DRAWINGS, AND/OR HEREIN INCLUDING ALL INCIDENTALS AND ACCESSORIES NECESSARY AND REQUIRED FOR INSTALLATION OR MOUNTING, OR NORMALLY SUPPLIED BY COMMON PRACTICE WHETHER SPECIFICALLY MENTIONED OR NOT, TO PROVIDE COMPLETE AND PROPERLY FUNCTIONING SYSTEMS. 1.06 BRING ANY NON -COMPLIANCES WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS, CONFLICTS AND DISCREPANCIES TO THE ENGINEER'S ATTENTION BEFORE SUBMITTING BID. A CORRECT, COMPLETE AND EASILY MAINTAINED SYSTEM IS INTENDED. 1.07 THE CONTRACTOR'S BID WILL BE CONSTRUED AS AN AGREEMENT TO COMPLETE THE WORK WITHOUT ADDITIONAL COST TO THE OWNER. WHERE CONFLICTS BETWEEN PLANS AND SPECIFICATIONS OR CONFLICTING INFORMATION ON THE PLANS OCCURS, THE CONFLICTS SHALL BE REPORTED TO THE ARCHITECT PRIOR TO BIDDING. THE MORE COSTLY ALTERNATIVE SHALL BE INCLUDED IN THE BID PRICE. 1.08 MAKE NO CHANGES IN THE WORK SPECIFIED, UNLESS SUCH CHANGES ARE AUTHORIZED IN WRITING BY THE OWNER, ARCHITECT AND/OR ENGINEER. NO CHARGES FOR EXTRA WORK WILL BE PAID UNLESS SUCH EXTRA WORK HAS BEEN AUTHORIZED AND THE AUTHORIZATION CONTAINS A STATEMENT OF THE WORK TO BE ACCOMPLISHED AND THE CHARGES TO BE MADE FOR THE WORK. 1.09 IT IS THE INTENT OF THESE SPECIFICATIONS TO PROVIDE A MECHANICAL SYSTEM COMPLETE, FULLY ADJUSTED, AND READY TO USE. 1.10 IT IS THE INTENTION OF THESE SPECIFICATIONS AND DRAWINGS TO CALL FOR FINISHED WORK, TESTED, AND READY FOR OPERATION. WHEREVER THE WORK "PROVIDE" IS USED, IT SHALL MEAN "FURNISH AND INSTALL COMPLETE AND READY TO USE." MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR THE PROPER INSTALLATION AND OPERATION, SHALL BE INCLUDED IN THE WORK, THE SAME AS IF HEREIN SPECIFIED OR SHOWN. 1.11 THE CONTRACTOR SHALL GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS AND PAY ALL GOVERNMENT SALES TAXES, FEES AND OTHER COSTS, INCLUDING UTILITY CONNECTIONS OR EXTENSIONS, IN CONNECTION WITH HIS WORK; FILE ALL NECESSARY PLANS, PREPARE ALL DOCUMENTS AND OBTAIN ALL NECESSARY APPROVALS OF ALL GOVERNMENTAL DEPARTMENTS HAVING JURISDICTION; OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION OF HIS WORK AND DELIVER SAME TO THE ARCHITECT BEFORE REQUEST FOR ACCEPTANCE AND FINAL PAYMENT FOR WORK. 1.12 THE CONTRACTOR SHALL INCLUDE IN THE WORK, WITHOUT EXTRA COST TO THE OWNER, ANY LABOR, MATERIALS, SERVICES, APPARATUS, DRAWINGS, IN ORDER TO COMPLY WITH ALL APPLICABLE LAWS, ORDINANCES, RULES AND REGULATIONS, WHETHER OR NOT SHOWN ON DRAWINGS AND/OR SPECIFIED. PART 2.00 PRODUCTS 2.01 MATERIALS AND EQUIPMENT SUBSTITUTIONS: THE BID PRICE SHALL BE BASED ON THE MATERIALS, EQUIPMENT AND/OR SERVICES AS SCHEDULED ON THE DRAWINGS AND/OR SPECIFIED HEREIN, AND/OR AS ACCEPTED PRIOR TO BIDDING. 2.02 REQUESTS FOR ACCEPTANCE OF ALTERNATIVES SHALL BE SUBMITTED TEN (10) DAYS PRIOR TO BID. 2.03 ACCEPTANCE OF ALTERNATE OR SUBSTITUTE EQUIPMENT IN NO WAY VOIDS MATERIAL OR PERFORMANCE REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PERFORMANCE OF ANY MATERIAL OR EQUIPMENT SUBSTITUTED FOR SPECIFIED ITEMS ACCEPTED BY THE ARCHITECT AND/OR ENGINEER BEFORE OR AFTER THE BID DATE. CONTRACTOR SHALL BE RESPONSIBLE FOR INCORPORATING ANY SUBSTITUTE EQUIPMENT IN THE SYSTEM DESIGN. 2.04 CONTRACTOR SHALL PAY FOR ALL EXTRA COSTS BY ANY TRADE FOR CHANGES NECESSITATED BY MATERIAL OR EQUIPMENT SUBSTITUTIONS REGARDLESS OF ACCEPTANCE WITHOUT FURTHER COST TO THE CLIENT. 2.05 REVIEW OF MATERIALS AND EQUIPMENT: WITHIN 30 DAYS OF CONTRACT AWARD, SUBMIT FIVE COPIES OF EACH 2.06 GENERAL MATERIALS AND EQUIPMENT: ALL MATERIAL AND EQUIPMENT SHALL BE NEW AND OF THE BEST OF CATALOG GRADE INDICATED AND/OR SPECIFIED AND SHALL BE FREE FROM ALL DEFECTS. 2.07 MATERIAL AND EQUIPMENT SPECIFIED HEREIN SHALL BE GUARANTEED BY THE MANUFACTURER TO PERFORM TO STANDARDS INDICATED OR INFERRED IN PUBLISHED LITERATURE OR CATALOG DATA. MANUFACTURER'S RECOMMENDATIONS SHALL BE CLOSELY FOLLOWED ON INSTALLATION. 2.08 REFRIGERANT PIPING: TYPE "L" OR TYPE "K" WITH BRAZED HIGH TEMPERATURE SOLDER JOINTS. PIPE SHALL BE CLEAN AND TESTED FOR LEAKS. INSULATE SUCTION PIPING WITH 1 INCH THICK FIBERGLASS WITH FRJ JACKET SEALED WATER TIGHT. COVER OUTDOOR INSULATION WITH ALUMINUM OR PLASTIC JACKET APPLIED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2.09 ALL INSULATION SHALL HAVE A COMPOSITE (INSULATION, JACKET OR FACING, AND ADHESIVE) FIRE HAZARD RATING AS TESTED BY ASTM E-84, NFPA 255, OR UL 723, NOT TO EXCEED 25 FLAME SPREAD AND 50 SMOKE DEVELOPED. ACCESSORIES SUCH AS COATINGS, TAPES, AND ADHESIVES SHALL HAVE THE SAME COMPONENT RATINGS. ALL INSULATING MATERIALS OR THEIR CONTAINERS SHALL HAVE A LABEL INDICATING COMPLIANCE WITH THE ABOVE RATING. REFERENCE STANDARDS: NFPA D-255, A.S.T.M. E-84, UL -723, ASHRAE 90-75 AND THE STATE ENERGY CODE. ACCEPTABLE MANUFACTURERS: CERTAINTEED, OWENS-CORNING, KNAUF AND MANVILLE. PART 3.00 EXECUTION 3.01 PERMITS AND INSPECTIONS: APPLY AND PAY FOR ALL PERMITS AND CERTIFICATES OF INSPECTION REQUIRED FOR THE WORK, AND AT COMPLETION, PRESENT THE OWNER WITH THE SIGNED CERTIFICATES OF FINAL INSPECTION. 3.02 UTILITIES: CHARGES BY UTILITY COMPANIES FOR PROVIDING SERVICES SHALL BE PAID BY OWNER AND WILL NOT BE A PART OF THIS CONTRACT. THE CONTRACTOR SHALL DO INSTALLATION WORK NORMALLY PROVIDED IN THIS CONTRACT. 3.03 PLACE AND ARRANGE EQUIPMENT, PIPING, DUCTS, CONTROLS, ETC., TO FIT THE SPACE AVAILABLE. INCLUDING ALL OFFSETS IN PIPING OR DUCTS, DUCT TRANSFORMATIONS, ETC. REQUIRED. 3.04 SUBMIT SHOP DRAWINGS FOR TEMPERATURE CONTROL SYSTEMS, MECHANICAL EQUIPMENT WIRING, MECHANICAL EQUIPMENT AND MATERIALS WHICH CANNOT BE ADEQUATELY DESCRIBED BY MANUFACTURER'S PRINTED SHEETS, AND FOR SUCH ADDITIONAL ITEMS AS THE ARCHITECT/ENGINEER MAY DIRECT. 3.05 CLEARLY MARK SUBMITTALS AS TO PLAN CODE, SPECIFIC ITEM PROPOSED, CATALOG NUMBERS, RECESS OPENINGS, DIMENSIONS, CAPACITIES, ELECTRICAL CHARACTERISTICS, ETC.. SUBMITTALS WHICH ARE INCOMPLETE WILL BE REJECTED. 3.06 THE ENGINEER'S CHECK SHALL BE GENERAL, AND DOES NOT RELIEVE THE CONTRACTOR OF FINAL RESPONSIBILITY OF COMPLIANCE TO THE INTENT OF THE PLANS AND SPECIFICATIONS. 3.07 SUPERVISION AND WORKMANSHIP: QUALIFIED SUPERVISION FOR EACH TRADE SHALL BE IN CHARGE OF THE WORK AT ALL TIMES AND SHALL BE ON THE JOB SITE WHENEVER WORK IN THAT TRADE IS BEING ACCOMPLISHED. 3.08 ALL WORK SHALL BE DONE IN A FIRST-CLASS MANNER BY WORKMEN SKILLED IN THE TRADE AFFECTED. 3.09 CLEANING PIPING, DUCTS, EQUIPMENT: THOROUGHLY CLEAN ALL DUCTS AND EQUIPMENT OF DIRT, CUTTINGS, AND OTHER FOREIGN SUBSTANCES. REMOVE FROM PREMISES ALL FUBBISH AND DEBRIS, LEAVING THE AREA CLEAN AND READY FOR USE. 3.10 EQUIPMENT START-UP: ADJUST ALL BELTS, OR OTHER DRIVES AND CHECK MOTOR ROTATIONS. 3.11 INSTALL TEMPORARY AIR FILTERS IN AIR HANDLING EQUIPMENT THAT IS BEING USED FOR HEATING OR VENTILATION DURING CONSTRUCTION. INSTALL A NEW SET OF THE SPECIFIED AIR FILTERS FOR THE EQUIPMENT AT THE COMPLETION OF THE JOB. 3.12 COMPLETION: OPERATE ALL MECHANICAL SYSTEMS, INCLUDING ALL EQUIPMENT FURNISHED UNDER THIS DIVISION FOR A PERIOD OF TIME NOT TO EXCEED 5 DAYS OR AS MNY BE REQUIRED AT THE DIRECTION ON THE ARCHITECT/ENGINEER TO PROVE THAT ALL COMPONENTS ARE PROPERLY OPERATING AND THAT THE COMPLETE INSTALLATION IS FUNCTIONING SMOOTHLY AND NOISELESSLY TO THE FULL EXTENT OF PLANS AND SPECIFICATIONS, ANY REBALANCING, READJUSTING OF SYSTEM ELEMENTS FOUND NECESSARY WHEN THE SYSTEMS ARE SUBJECT TO ACTUAL OPERATING CONDI TIONS SHALL BE DONE BY THE CONTRACTOR AT NO EXTRA COST TO THE OWNER. 3.13 OPERATING INSTRUCTIONS: SUBMIT 30 DAYS PRIOR TO COMPLETION DF THE PROJECT, FOUR (4) SETS OF OPERATING BROCHURES. EACH BROCHURE SHALL INCLUDE OPERATING INSTRUCTIONS, MAINTENANCE INSTRUCTIONS, INSTALLATION INSTRUCTIONS, PARTS LISTS AND WIRING DIAGRAMS FOR EACH ITEM OF MECHANICAL EQUIPMENT WITH MIXING OR MOVABLE PARTS. THE BROCHURE SHALL ALSO INCLUDE OPERATIONAL AND DIAGRAMS OF TEMPERATURE CONTROL SYSTEMS. 3.14 PROVIDE TYPEWRITTEN OPERATING INSTRUCTIONS IN THE BROCHURE COVERING EACH PIECE OF MOTORIZED MECHANICAL EQUIPMENT, GIVE NORMAL STARTING AND STOPPING PROCEDURES, ALONG WITH PROPER PARTIES TO CONTACT IN THE EVENT OF EMERGENCY, FAILURE OF CONTROLS OR EQUIPMENT. OUTLINE OF INSTRUCTIONS AS FOLLOWS: NORMAL STARTING, STOPPING AND EMERGENCY SHUT -DOWN CF EACH PIECE OF MOTORIZED EQUIPMENT. PROVIDE LUBRICATION INSTRUCTIONS FOR EACH MOTOR BEARING OR OPERABLE PIECE OF EQUIPMENT. GIVE FREQUENCY OF LUBRICATION, TYPE AND BRAND OF OIL DR GREASE. INCLUDE CALIBRATION, CLEANING AND ADJUSTMENT SCHEDULES AND PROCEDURES. INCLUDE COPIES OF MANUFACTURER'S LITERATURE ON MAINTENANCE AND OPERATION OF EACH PIECE OF EQUIPMENT, INCLUDING INSTALLATION INSTRUCTIONS, DIAGRAMS, AND PARTS LISTS, IN EACH BROCHURE. 315 AS -BUILT DRAWINGS: SUBMIT AS -BUILT DRAWINGS AT COMPLETION DF WORK. 3.16 GUARANTEE: THE MECHANICAL SYSTEM SHALL BE LEFT IN PROPER WORKING ORDER. REPLACE ANY WORK, MATERIAL OR EQUIPMENT PROVIDED UNDER THIS CONTRACT WHICH D VELOPS DEFECTS WITHIN ONE (1) YEAR FROM DATE OF SUBSTANTIAL COMPLETION WITHOUT ADDITIONAL CHARGES. A NEW ONE (1) YEAR GUARANTEE ON THE AFFECTED ITEM OR ITEMS SHALL BE PROVIDED COMMENCING ON THE DATE OF THE APPROVED REPAIR OR REPLACEMENT. 3.17 MECHANICAL EQUIPMENT WIRING AND CONNECTIONS: ITEM EQUIPMENT MOTORS MOTOR CONTROLLERS, PUSHBUTTON STATIONS, PILOT LIGHTS, ETC. MULTI -SPEED SWITCHES LINE VOLTAGE THERMOSTATS BY MC FURNISHED MC MC OR MOUNTED BY MC INSTALLED EY EC EC DISCONNECT SWITCHES, (FUSED OR UNFUSED), HP RATED SWITCHES, THERMAL OVERLOAD SWITCHES, ETC. MC EC LOW VOLTAGE THERMOSTATS, CONTROL RELAYS, TIME CLOCKS, CONTROL TRANSFORMER, CONTROL PANELS, PRESURESTATS, MOTOR VALVES, DAMPER MOTORS, SOLENOID VALVES, EP & PE SWITCHES, ETC. AND ALL INTERLOCK WIRING MC MC MC - MECHANICAL CONTRACT EC - ELECTRICAL CONTRACT CONNECTED BY EC WIRED AND/OR EC THE MECHANICAL CONTRACTOR SHALL FURNISH ALL MAGNETIC STARTERS OR CONTACTORS. EC EC MC 3.18 ALL MANUAL OR AUTOMATIC CONTROL AND PROTECTIVE OR SIGNAL DEVICES REQUIRED BUT NOT INDICATED ON ELECTRICAL PLANS SHALL BE FURNISHED AND INSTALLED UNDER THIS DIVISION OF THE SPECIFICATIONS. THE WIRING INSTALLATION SHALL CONFORM TO ELECTRICAL DIVISION. 3.19 3.20 3.21 3.22 3.23 3.24 3.25 ALL WIRING CONNECTIONS TO CONTROLS ATTACHED TO DUCT WORK, DR MECHANICAL EQUIPMENT SHALL BE MADE WITH FLEXIBLE CONNECTIONS TO PREVENT VIBRATION. COORDINATE WITH THE ELECTRICAL CONTRACTOR BEFORE ORDERING MOTORS AND/OR OTHER ELECTRICAL EQUIPMENT TO ASSURE ELECTRICAL EQUIPMENT BEING OF PROPER ELECTRICAL CHARACTERISTICS. FURNISH PROPER NEMA TYPE ENCLOSURES FOR ALL STARTERS AND/OR CONTACTORS AS REQUIRED BY USAGE OR CODE. PROVIDE HEAVY DUTY SPEED SELECTOR SWITCHES, THERMAL MAGNETIC SWITCHES, START STOP PUSH BUTTON STATIONS ETC. AS REQUIRED. CUTTING AND PATCHING: CAREFULLY PERFORM ALL WORK WHERE CUTTING, CHANNELING, CHASING, OR DRILLING OF FLOORS, WALLS, PARTITIONS, CEILINGS OR OTHER SURFACES IS NECESSARY FOR PROPER INSTALLATION OR SUPPORT OF DUCTS, PIPINGS, OR OTHER MECHANICAL EQUIPMEN T. ANY DAMAGE TO BUILDING, PIPING, EQUIPMENT, PLASTER, WOODWORK OR METAL WORK SHALL BE REPAIRED BY SKILLED MECHANICS OF TRADES INVOLVED, AT NO ADDITIONAL COST TO THE OWNER. DO NOT CUT, CHANNEL, CHASE OR DRILL MASONRY OR TILE; OR CUT, DRILL OR WELD STRUCTURAL MEMBERS OF THE BUILDING, ETC., WITHOUT FIRST OBTAINING ARCHITECT'S PERMISSION, IF PERMISSION IS GRANTED, PERFORM THIS WORK IN A MANNER APPROVED BY THE ARCHITECT. 3.26 CAULKING & WATERPROOFING: CAULK AROUND ALL PIPES, ETC. TO PREVENT AIR AND MOISTURE LEAKAGE WITH COMPOUND APPROVED BY ARCHITECT/ENGINEER. 3.27 3.28 3.29 INSERTS, SLEEVES & BLOCKOUTS: FURNISH AND INSTALL, PRIOR TO CONCRETE POURING OR OTHER CONSTRUCTION, INSERTS, SLEEVES, OR BLOCKOUTS IN WALLS, FLOOR SLABS, ROOFS AND PARTITIONS FOR PASSAGE OF ALL WORK INSTALLED UNDER THIS .DIVISION. SEAL AROUND ALL PIPES AND DUCTS WITH FIREPROOF CAULKING OR GROUT WHERE THEY PASS THROUGH FLOORS, FIREWALLS, AND SHAFTS. PROVIDE FLASHINGS WHERE ALL PIPES AND DUCTS PIERCE OUTSIDE WALLS OR ROOF AS NECESSARY TO PREVENT MOISTURE ENTRY. 3.30 PROVIDE GALVANIZED IRON AND STEEL PIPE SLEEVES FOR IRON PIPES. USE COPPER SLEEVES FOR COPPER PIPES. PROVIDE WOOD OR STEEL BLOCKOUTS FOR LARGE OPENINGS. SECURE ALL SUCH ITEMS FIRMLY IN POSITION. 3.31 VIBRATION -ABSORBING MOUNTINGS AND CONNECTIONS: ISOLATE EACH ITEM OF EQUIPMENT WITH MOVING PARTS FROM THE BUILDING STRUCTURE ALONG WITH ANY PIPING, CONDUITS, OR DUCTS ATTACHED THERETO. UNLESS OTHERWISE INDICATED, UNITS ISOLATING EQUIPMENT FROM STRUC TURE SHALL BE PROPERLY DESIGNED SPRING -TYPE ISOLATORS. 3.32 BELT DRIVE GUARDS: PROVIDE BELT DRIVE GUARDS FOR ALL EQUIPMENT AND SAFETY SCREENS ON EXPOSED FAN INLETS. 3.33 VALVES: NIBCO BALL VALVES OR EQUAL. 3.34 NOT USED. 3.35 NOT USED. 3.36 PROVIDE PRODUCTS OF COMBUSTION DETECTOR IN SUPPLY AND RETURN AIR IN ALL UNITS 2000 CFM OR OVER TO SHUT DOWN UNIT ON ALARM CONDITION. 3.37 EXHAUST FANS: FANS SHALL MEET CAPACITIES SCHEDULED AND NOT EXCEED SOUND LIMITATIONS SPECIFIED. 3.38 GRILLES & REGISTERS: SCHEDULED ON DRAWINGS. TITUS OR EQUAL. 3.39 DUCT LINING: 1/2" THICKNESS, 3 PCF DENSITY, NEOPRENE COATED DUCT LINER MEETING FIRE HAZARD RATING REQUIREMENTS FOR INSULATION. INSTALL WITHIN MINIMUM 10' DUCT LENGTH FROM FANS. 3.40 DUCTWORK: SHEET METAL DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED STEEL. DUCTS SHALL CONFORM ACCURATELY TO THE DIMENSIONS INDICATED AND SHALL BE STRAIGHT AND SMOOTH ON THE INSIDE WITH JOINTS NEATLY FINISHED. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH SMACNA LOW PRESSURE DUCT MANUAL, 2" WG FOR SUPPLY & 1" WG FOR EXHAUST DUCTS. ELBOWS, FITTINGS AND BRANCH TAKE -OFFS SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED AS RECOMMENDED IN SMACNA "DUCT CONSTRUCTION STANDARDS" WITH THE USE OF TURNING VANES OR RADIUS ELBOWS. FLEXIBLE RUNOUTS FROM BRANCHES, RISERS OR MAINS TO AIR TERMINAL UNITS, AND OUTLETS SHALL BE FACTORY -FABRICATED, CLASS I, VAPOR BARRIER INSULATED FLEXIBLE CONNECTORS COMPLYING WITH NFPA STANDARD NO. 90A AND UL 181. FLEXIBLE CONNECTORS SHALL NOT EXCEED 10' IN LENGTH. PRESSURE RATING SHALL BE 4" W.G. FLEXIBLE DUCT CONNECTIONS TO EQUIPMENT AND OTHER DUCTS SHALL BE MADE WITH DRAW BANDS. PROVIDE DAMPER IN RUN OUT TO AIR OUTLETS. 3.41 HINGED DUCT ACCESS DOORS SHALL BE PROVIDED AT ALL AUTOMATIC DAMPERS, FIRE DAMPERS, AND OTHER APPARATUS REQUIRING SERVICE AND INSPECTION IN THE DUCT SYSTEM. DOORS SHALL BE 15 X 18 INCHES UNLESS OTHERWISE INDICATED. WHERE SIZE OF DUCT WILL NOT ACCOMMODATE THIS SIZE, THE DOOR SHALL BE MADE AS LARGE AS PRACTICAL. DOORS SHALL BE PROVIDED WITH AIRTIGHT GASKETS, GALVANIZED HINGES AND APPROVED BRASS FASTENERS. DOORS IN INSULATED DUCTS SHALL BE OF THE INSULATED TYPE. DOORS SHALL SO SWING THAT FAN PRESSURE OR SUCTION HOLD DOOR CLOSED. 3.42 PROVIDE NON-COMBUSTIBLE APPARATUS FLEXIBLE CONNECTIONS OF NOT LESS THAN 15 OUNCE WOVEN FABRIC APPROVED MATERIAL WHERE SHEET METAL DUCTS ARE CONNECTED TO FANS OR OTHER MOVING EQUIPMENT. THE FLEXIBLE CONNECTIONS SHALL BE SECURELY FASTENED. 3.43 DUCT LINER INSULATION: INSULATE INTERIOR SURFACES OF ALL HP -1, HP -2 SUPPLY DUCTS FROM AIR CONDITIONING UNIT SUPPLY FANS TO AIR OUTLETS AND INDICATED RETURN OR EXHAUST DUCTS WITH ACOUSTICAL MATERIAL. 3.44 APPLY AND SECURE INSULATION AS RECOMMENDED BY MANUFACTURER AND AS APPROVED. ANY LOOSENING OF INSULATION LINER WILL REQUIRE REMOVAL AND REINSTALLATION OF ALL DUCT WORK, AT NO EXTRA COST. 3.45 INCREASE INDICATED DUCT SIZES TO COMPENSATE FOR THICKNESS OF DUCT UNER INSULATION. SEALING: ALL TRANSVERSE JOINTS ON THE LOW PRESSURE SYSTEM SHALL BE SEALED WITH "HARDCAST" DUCT TAPE SYSTEM APPLIED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS OR OTHER APPROVED SYSTEM. 3.46 IN LIEU OF RECTANGULAR LINED DUCT, RECTANGULAR DUCT INSULATED WITH 1" VAPOR BARRIER DUCT WRAP OR ROUND DUCT OF EQUIVALENT CROSS SECTIONAL AREA AND INSULATED WITH 1" VAPOR BARRIER INSULATION, MAY BE USED. 3.47 NOT USED 3.48 DESCRIPTION: PERFORM TESTING AND BALANCING IN ACCORDANCE WITH THE PROCEDURE OF THE ASSOCIATED AIR BALANCE COUNCIL'S "NATIONAL STANDARDS FOR FIELD MEASUREMENTS AND INSTRUMENTATION TOTAL SYSTEM BALANCE." 3.49 USE ACCURATE INSTRUMENTS FOR BALANCING AIR SYSTEMS THAT HAVE BEEN CALIBRATED WITHIN 6 MONTHS PRIOR TO BALANCING. TYPES, SERIAL NUMBERS, AND DATE OF CALIBRATION OF ALL INSTRUMENTS SHALL BE LISTED IN THE FINAL AIR BALANCE REPORTS. 3.50 MAKE AIR QUANTITY MEASUREMENTS IN MAIN AND BRANCH DUCTS BY PITOT TUBE TRAVERSE OF THE ENTIRE CROSS SECTIONAL AREA OF THE DUCT. DUCTS HAVING VELOCITIES OF 1000 OR MORE FEET PER MINUTE SHALL BE MEASURED WITH INCLINED MANOMETERS (DRAFT GAUGE) OR MAGNEHELIC GAUGES. DUCTS HAVING VELOCITIES OF LESS THAN 1000 FT. PER MINUTE SHALL BE MEASURED WITH MICROMANOMETERS, HOOD GAUGES OR SIMILAR LOW PRESSURE INSTRUMENTS. OPENINGS IN DUCTS FOR PITOT TUBE INSERTION SHALL BE SEALED WITH SNAP -IN PLUGS AFTER AIR BALANCE IS COMPLETE. OUTLET AND INLET AIR QUANTITIES SHALL BE DETERMINED BY AN APPROVED METHOD. 3.51 TOTAL AIR QUANTITIES SHALL BE OBTAINED BY ADJUSTMENT OF FAN SPEEDS. THE BALANCING CONTRACTOR SHALL FURNISH AND INSTALL ANY REQUIRED FAN DRIVE CHANGES AS PART OF THIS CONTRACT. 3.52 VOLUME ADJUSTERS MAY BE USED TO BALANCE AIR QUANTITIES AT OUTLETS AND INLETS PROVIDING FINAL ADJUSTMENTS ARE MINOR AND DO NOT PRODUCE OBJECTIONABLE DRAFTS OR EXCESSIVE SOUND LEVELS. 3.53 CERTIFIED BALANCE REPORTS: THREE (3) COPIES OF THE AIR AND WATER BALANCE REPORT, CERTIFIED BY THE BALANCING FIRM, SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER SEVEN (7) DAYS PRIOR TO FINAL ACCEPTANCE OF THE PROJECT. THE REPORT SHALL INCLUDE ALL AIRAND WATER BALANCE DATE AND HEAT TRANSFER EQUIPMENT TEST DATA LISTED BELOW, AND OTHER DATA AS REQUIRED BY THE "NATIONAL STANDARD FOR FIELD MEASUREMENTS AND INSTRUMENTATION". 3.54 3.55 NOT USED. INDIVIDUAL OUTLET AND INLET TEST RESULTS: OUTLET AND INLET IDENTIFICATION (LOCATION AND NUMBER DESIGNATION). 3.56 FOLLOWING FINAL ACCEPTANCE OF THE SYSTEM BALANCE BY THE OWNER, THE CONTRACTOR SHALL PERMANENTLY MARK THE SETTINGS OF ALL VALVES, SPLITTERS, DAMPERS, AND OTHER ADJUSTMENT DEVICES SO THAT ADJUSTMENT CAN BE RESTORED IF DISTURBED AT ANY TIME. DEVICES SHALL NOT BE MARKED BEFORE FINAL ACCEPTANCE. 3.57 NO STRUCTURAL MEMBERS SHALL BE CUT WITHOUT THE APPROVAL OF THE ARCHITECT, AND ALL SUCH CUTTING SHALL BE DONE IN A MANNER DIRECTED BY HIM. 3.58 PROVIDE WEATHER-PROOF FLASHING AT ALL DUCT, PIPE, ETC. MECHANICAL PENETRATIONS THROUGH THE BUILDING WALLS AND ROOF. FLASHING SHALL BE DESIGNED AND INSTALLED PER SMACNA AND SHALL BE GUARANTEED WEATHER PROOF FOR THE DURATION OF THE GUARANTEE. Mtl 00 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 11 2017 City of Tukwila BUILDING DIVISION RECE=IVED CITY OF TUKWILA JUN 29 2017 PERMIT CENTER ABOSSEIN ENGINEERING L.L.0 MECHANICAL - FT,FCTRICAL CIVIL - LEED - STRUCTURAL FIRE PROTECTION 2100 112TH AVE. NE BEI.T,FVUE, WA 98004 OFFICE: (425) 462-9441 FAX: (425) 462-9451 EMAIL: CService@abossein.com WEBSITE: www.abos , in.com 2867 SOUTHCENTER MALL TUKWILA, WA 98188