Loading...
HomeMy WebLinkAboutPermit M17-0097 - ARDANS RESIDENCE - FURNACEARDANS RESIDENCE 5534 S 144 ST MI 7-0097 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 3365900206 5534 S 144TH ST ARDANS RESIDENCE MECHANICAL OTC PERMIT Permit Number: M17-0097 Issue Date: Permit Expires On: 7/5/2017 1/1/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: ARDANS KATHRYN A+JONATHAN M 5534 S 144TH ST, TUKWILA, WA, 98168 KATHRYN ARDANS 5534 5 144TH ST, TUKWILA, WA, 98188 GREEN CITY HTG & A/C INC 948 INDUSTRY DR , TUKWILA, WA, 98188 GREENCH866B2 111 Phone: Phone: (206) 227-6616 Expiration Date: 1/22/2018 DESCRIPTION OF WORK: REMOVE/REPLACE FURNACE - Valuation of Work: $2,707.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $198.44 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 Permit Center Authorized Signature:4 11/44 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Dater ' r' I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit aid agree to the conditions attached to this permit. Signature: Print Name: V-ekUD� vt This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: T(» / ii - PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Type 1 Hoods, the required grease duct leakage test and light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL 4 CITY OF TUKWi Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. 11,11- 00(n Date Application Accepted: Date Application Expires: 1- t (For office rise only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION I - - --King.Co-Assessor's Tax No.: Site Address: SSZ✓A S ltitAA % S}' 1-rUt uNt \Q t v)(1- ftiiog Suite Number: ),J ( Pr Floor: N�� Tenant Name: 4A44A phdots f RSV kn0101/4 New Tenant: ❑ Yes 0.. No PROPERTY OWNER Name: 4 Nraiws. Name: I . _ ,4 e,yaolvI. 4 7-evost, , AottAva Address: ss3a s Not. sk Email: aYdOlhS e rpt,p i I. CO h.,‘ City: ,rujiG�, State: top, Zip: love CONTACT PERSON - person receiving all project co11111111nicatl011 Name: 4 Nraiws. Address: s 6...a4 S \ tkou 5A... City:.* r. kA State: tiofl Zip: aFstiog Phone: -47,1-. ei3i. 3bir Fax: N IA Email: aYdOlhS e rpt,p i I. CO h.,‘ MECHANICAL CONTRACTOR INFORMATION Company Name: qYvity% ci 60 1 __.4 e Address: q gi s T City:1.0..wAla 0 State: opc Zip: is(s& Phone: 2ol0.Z24.or.,ip Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: n REe NLkA 8100E2 Valuation of project (contractor's bid price): $ pC -[3-,1.3 Describe the scope of work in detail: Pe"a e. '€Ct fLettit FurnaCc . 1-4Asviiisi.1..(24110)! C2300 IV Use: Residential: New ❑ Replacement Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 r CI Indicatertype of mechanical work being installed and the quantity below: r Unit Aypr. . 3 1 d v Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater ,57 dB(A) Appliance vent Coirimercial"' ` Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm °' ' ' ' 60 -iB(A) ' Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct ,57 dB(A) Ventilation system Coirimercial"' ` Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial °' ' ' ' 60 -iB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove ,57 dB(A) Emergency generator Coirimercial"' ` Other mechanical equipment 47 dB(A) ' 60 dB(A) 65 dB(A) Boiler/Compressor Qh' 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: r r , a Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound cad•be'heard•from'within a house at nightih'a residentiarzone`it may not be allowed. For more details, see TMC 8.22 *Daytim District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 1 55 dB(A) 45 dB(A) ,57 dB(A) 60 dB(A) Coirimercial"' ` `'` 57 dB(A) 47 dB(A) ' 60 dB(A) 65 dB(A) Industrial ' °' ' ' ' 60 -iB(A) 50 dB(A) 65 dB(A) ` 70 dB(A) A few sounds are exempt from the noise code including:' • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); Testing.of backup generators during the day. PERMIT APPLICATION NOTES - • Value of construction— in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. •, Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). :1 HEREBY CERTIFY THAT I HAVE READ AND"EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Oj, E f ,/ RR AUT ORIZED AGENT: Signature: (O` d✓ Print Name: meq" fit P1400n S Mailing Address: SS j` -I 3 i 4' V SA— H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Day Telephone: riu 1�v��1G 'City Date: f 1 I l 131. 3(oV) State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $198:44 M17-0097 Address:'55345144TH ST Apn: 3365900206 $198.44 Credit Card Fee $5.78 Credit Card Fee R000.369.908.00.00 0.00 $5.78 MECHANICAL .. $183.49 PERMIT FEE R000.322.100.00.00 0.00 $150.34 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $9.17 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11856 R000.322.900.04.00 0.00 $9.17 $198.44 Date Paid: Wednesday, July 05, 2017 Paid By: KATHRYN ARDANS Pay Method: CREDIT CARD 515050 Printed: Wednesday, July 05, 2017 1:09 PM 1 of 1 CRIVSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r11117-001' 7 „vim �la . 3670 6300 Southcenter on Request 0, Tukwila. WA 1 Line (206) 438- 350 (206) 4344_ Project: P-RDENS kmbioucE Type of Inspection: Rai 064-1 -M gci�irlJi Cer 1.. Address: 553V 2 r Lilt/44 7-1 Date Called: Special Instructions: Date Wanted: '7-(Q`I7 a.m. p.m. Requester: Phone No: 7? qr3/-36-O rri Approved per applicable codes. Corrections required prior to approval. COMMENTS: ag ,6,7u2A-1_ Inspector: REINSPECTION FEE REQUIRED. Prior to next inspeckion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Green City HTG & A/C INC Rinne Enspafiol Contict. Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Page 1 of 3 Search L&I A -Z Index Help Workplace Rights Trades & Licensing Green City HTG & A/C INC Owner or tradesperson Principals Simonson„ Jeffrey Orvold, PRESIDENT Simonson, Katrina Marie, SECRETARY Doing business as Green City HTG & A/C INC WA UBI No. 603 363 739 948 INDUSTRY DR TUKWILA, WA 98188 206-227-6616 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. GREENCH866B2 Effective — expiration 01/22/2014— 01/22/2018 Bond Wesco Insurance Co Bond account no. 46W B079066 $6,000.00 Received by L&I Effective date 08/25/2016 08/19/2016 Expiration date Until Canceled Bond history Insurance Arch Specialty Ins Co $1,000,000.00 Policy no. AGL0043156-00 Received by L&I. Effective date 11/17/2016 11/18/2016 Expiration date 11/18/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 16-2-02889-6 Open Help us improve https://secure.ini.wa.gov/verify/Detail.aspx?UBI=603363739&LIC=GREENCH866B2&SAW= 7/5/2017 Green City HTG & A/C INC Complaint filed by NADA & JAMES DOHERTY Complaint against bond(s) or savings 100180935 Complaint date Complaint amount 02/14/2016 $0.00 L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. EJOJP00386 Issue date 08/26/2015 Violation city BONNEY LAKE Type of violation ELECTRICAL CITATION Description Offering, bidding, advertising, or performing electrical installations, alterations or maintenance outside the scope of the firm's specialty electrical contractors license. Satisfied RC WNVAC 19.28.041 RCW Violation amount $500.00 Infraction no. EJOJP00388 Issue date 08/26/2015 Violation city BONNEY LAKE Type of violation ELECTRICAL CITATION Description Energizing electrical equipment without an electrical inspection as referenced in WAC 296-46B-901. Satisfied RCW/WAC 19.28.101 RCW Violation amount $250.00 Infraction no. EJOJP00387 Issue date 08/26/2015 Violation city BONNEY LAKE Type of violation ELECTRICAL CITATION Description Employing an individual for the purposes of chapter 19.28 RCW who does not possess a valid certificate of competency or training certificate to do electrical work. Satisfied RCW/WAC 19.28.271 RCW Violation amount $250.00 Infraction no. EJOJP00385 Issue date 08/26/2015 Violation city BONNEY LAKE Type of violation ELECTRICAL CITATION Description Class B eligible work - Failure of the person identified as the installer on the Class B label to post a Class B label, or number if allowed. (See WAC 296-46B-908.) 15448 SE 167 PL, RENTON Satisfied RCW/WAC 19.28.101 RCW Violation amount $100.00 Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603363739&LIC=GREENCH866B2&SAW= 7/5/2017