HomeMy WebLinkAboutPermit M17-0107 - CASCADE VIEW ELEMENTARY - REFIGERATION PIPINGCASCADE VIEW ELEMENTARY 13601 32ND AVE S M17-0107 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto://www.TukwilaWA.sov MECHANICAL PERMIT 1623049038 Permit Number: 13601 32ND AVE S Project Name: CASCADE VIEW ELEMENTARY Issue Date: Permit Expires On: M 17-0107 8/25/2017 2/21/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST, TUKWILA, WA, 98168 KYLE REYNOLDS 6716 EASTSIDE DR NE #1-104 , TACOMA, WA, 98422 AMERICAN RFRG & CONTROL LLC 6716 EASTSIDE DR NE #1-104 , TACOMA, WA, 98422 AMERIRC873KU Phone: (253) 653-2456 Phone: (253) 653-2456 Expiration Date: 5/31/2019 DESCRIPTION OF WORK: INSTALL REFRIGERATION PIPING FOR WALK-IN FREEZER Valuation of Work: $2,500.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $245.69 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: NONE,VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Date: (Dc(aS(l7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: 1�"' \ Date: 5 -2 � ) R Print Name: c)/- This Q This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: Maintain a 4 foot clear space around the sprinkler riser(s) for emergency access. (NFPA 25) (City Ordinance #2436) 11: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 13: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKh _..A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Vi 17 -OE07 Project No. Date Application Accepted: 8^{ Q--( 7 Date Application Expires: 0 ^ (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION & OU-W,Oik �WYVVPS Q King Co Assessor's Tax No.: Site Address: (Jt'O 1 �Z'4WE 5 Suite Number: Tenant Name: ` CC,C %)) �� EL -R, tAk-en New Tenant: ❑ Yes Floor: PROPERTY OWNER Name: r� O `y(io)CA I.-C� Address: /' „1) ` s)eit Ovt. , ".l0`-) Cit t (.7k.„1 State: 7,49 Zip, 159 ZZ Name:, _,) )01 32hov -01.,..k < Address: City: State: Zip: CONTACT PERSON - person receiving all project communication Name: r� O `y(io)CA I.-C� Address: /' „1) ` s)eit Ovt. , ".l0`-) Cit t (.7k.„1 State: 7,49 Zip, 159 ZZ Phone: Zh--3 (.'S g Zy: Email: D id> Ftp -e z,e_ 0 ci,vQ0),rlovi MECHANICAL CONTRACTOR INFORMATION Company Name: W\-sZl1«6--fk fes`' t etiS Address:I „ i Crn L S wi 0 .i.2..„' /,_)C? `) City10,(4;\ State: Zip1isti2Z Phone: ,,LS. -5 �� z(45,xe,Fax: Contr Re No.: . aExp Date: c �,.c_..„5 ..,...s s- ll Tukwila Business License No.: Valuation of project (contractor's bid price): $ l ¶TO Describe the scope of work in detail: 1v' 5 \Ll 1 1z e_ir��iz.-rJ �- �d' vJ Use: Residential: New Commercial: New Fuel Type: Electric Replacement Replacement Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refriglcooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard.from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytim A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY AT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF P :; Y / E LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN i jam, ER�i ;� ► THORIZED AGENT: Signature: Print Name: Day Telephone: Date: �» -1- ZSR 60C3 z --‘71S-1) Mailing Address: J I,h j ;`S�SNI 1 J(L !i ) ' if/ J e Gk'1.'-'‘. ( %V ar City State Zip H:\Applications\Forms-Applications On Line\2016 Applications'Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila R12085 DESCRIPTIONS ACCOUNT I QUANTITY ' PAID $245.69 PermitTRAK M17-0107 Address: 13601 32ND AVE S Apn: 1623049038 $245.69 Credit Card Fee $7.16 Credit Card Fee R000.369.908.00.00 0.00 $7.16 MECHANICAL $229.36 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $150.34 PLAN CHECK FEE R000.322.102.00.00 0.00 $45.87 TECHNOLOGY FEE $9.17 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12085 R000.322.900.04.00 0.00 ' $9.17 $245.69 Date Paid: Thursday, August 10, 2017 Paid By: KYLE REYNOLDS Pay Method: CREDIT CARD 151808 Printed: Thursday, August 10, 2017 9:15 AM 1 of 1 CSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: e�ype of Inspection: Address: /360/ 02,120 Avg - Date Called: 11 Special Instructions: %t�ficti,F�IiLc1-L rt' Date Wanted: //7',39'7 a r p.m. Requester: 1 Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: OAC /344rt CSL Inspector: Date: // , /7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 W7-otc7 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: CASCADE' ✓d jj LZ'm@T� �r+".+cr v. W , T pe of Inspection: Address: /ulna/ 3.1%9 A✓C S', Date Called: Special Instructions: Date Wanted: (.O 2G•`)7 pim. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: p% OUTIOCACZ Mir eD 1 6'.0,(/ P, SIJIX ! Inspector: Date: 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit iq-c/O7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #.100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ect: D6 IPS Tye,of Inspection: F`' i . '"". kbth -/J.1 MatiA JJ L. Address:Date & o /' 32A b S Called: Special Instructions: Date W d: 2P /? Requeste : Phone No: EApproved per applicable codes. Corrections required prior to approval. COMMENTS: zs1.0 K -/ Y f /)1(7L ,IRsVArt -%mss 1 Inspector: Date: —26—J 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. wERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0107 DATE: 08/10/17 PROJECT NAME: CASCADE VIEW ELEMENTARY SITE ADDRESS: 1360132 AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AT (-47 Building Division Public Works PT 'NW, CO \i/P Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/15/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/12/17 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff initials: 12/18/2013 AMERICAN RFRG & CONTROL T T,C Horne Espanol Contact Safety & Health Claims & Insurance 6111111111Washington State Department of % Labor & Industries Search L&I Page 1 of 2 -ERIco A -Z Index help My I.,&1 Workplace Rights Trades & Licensing AMERICAN RFRG & CONTROL LLC Owner or tradesperson Principals REYNOLDS, KYLE ANSON, PARTNER/MEMBER Doing business as AMERICAN RFRG & CONTROL LLC WA UBI No. 603 303 983 6716 Eastside dr ne #1-104 TACOMA, WA 98422 253-653-2456 PIERCE County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. AMERIRC873KU Effective — expiration 05/31/2013— 05/31/2019 Bond ................. American Contractors Indem CO Bond account no. 10223253 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 05/31/2013 05/22/2013 Expiration date Until Canceled Insurance .. ................... Ohio Security Ins Co Policy no. BKS55579236 $1,000,000.00 Received by L&I Effective date 05/09/2017 05/22/2014 Expiration date 05/22/2018 Insurance history Savings ................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603303983&LIC=AMERIRC873KU&SAW= 8/25/2017 115/60/1 1.37 Amps 115/60/1 0.04 Amps HAV L� V///////////////////////////////////////// .//////////////////A ti 7- / -10° FREEZER WITH FLOOR SMOOTH ALUMINUM FINISH STANDARD CLOSURE PANELS EXTENDING ABOVE THE WALK-IN TO THE CEILING (ADVISE REQUIRED HEIGHT) NL708 ALARM/ LIGHT MANA3ER Lu ti 4 w • • • a■ . •.• EXTERIOR DOOR HEATER WIR INTERIOR FINISHED FLOOR MUST BE SWEEP TRANSIT LEVEL GASKET AND SMOOTH /S/S THRESHOLD VIEW -A- PARTITION WALL ��(IF APPLICABLE) VAPOR BARRIER: 6 MIL POLYETHYLENE OR 30 LBS. ASPHALT FELT OR HOT ASPHALT GROUT FILL .;* 411 .d"4•. • •••d..! • • 4' •• • . • 4 . -• •• . • - A d • . • . 44 d.• 3"x3" ANGLE TRIM STRIP STD. WITH FLOOR DETAIL IN A 4" RECESS . 4. ; . • . 4' • e . . • • 4 •• d. 4" MIN. SUB SLAB DETAIL 007C BD 8/19/02 DISTANCE ABOVE WALK-IN BUILDING CEILING 3/4" #8 SIS S.M.S. APPROX. 14" APART WALK-IN CLOSURE PANEL OVERLAP ON SIDE OF WALK-IN STANDARD CLOSURE PANEL DETAIL OPTIONAL FLASHING BY G.C.; FLASHING FROM BUILDING OVER TRIM AND MEMBRANE ROOF. FLASHING(by G.C.) CUT INTO BUILDING AND FASTENED BY GENERAL CONTRACTOR. MEMBRANE ROOF MATERIAL TRIM BY NOR LAKE DETAIL 029A BD 5/20/94 4 .12 WALK-IN COOLER/FREEZER 1 2" MAXIMUM — AIR SPACE (ELEVATION VIEW) WALK-IN MEMBRANE ROOF TRIM (1) LAWD200RL4-#BYH REMOTE REFRIGERATION SYSTEM R -404A, AIR COOLED, LOW TEMPERATURE 208-230/60/1 CONDENSING UNIT MCA 23.1, MAX FUSE 35, 352 LBS. UL APPROVED FLIP UP ALL WEATHER HOOD BUILDING DETAIL 040B DRAWN 8/19/02 REVISION 2/26/07 REVISION 8/16/10 SPECIFICATIONS D28946 (QUOTE NUMBER NL1755714SO-A) Nor -Lake is registered by UL to ISO 9001-2008. California State Contractor License #940932. (1) Nor -Lake FINELINE Walk -In Freezer 13' 0" long, 9' 0" wide, 7' 7" high. Finishes: 040 Smooth Aluminum - Interior wall, Interior ceiling 26 Gauge Corrosion Resistant Stucco Embossed Coated Steel - Exterior wall 040 Stucco Aluminum - Exposed wall, Exterior door frame, Exterior door 26 Gauge Smooth Galvanized - Ceiling topside, Floor bottomside .100 Smooth Aluminum - Interior floor REVISIONS No changes shall he made. to the scope of work Withol_:i prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees r • 1 FILE L^iPY Permit NO. IVII��\O- Plan Plan roview c,; ;..rov ; is subjoct to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: B Y� Date: ch -1C f City of Tukwila BUILDING DIVISION Outdoor Walk -In includes Flat White Membrane Roof With Trim — 45 Lbs./Sq. Ft. Ceiling Load Capacity Minimum. . (1) 36" X 78" Walk -In Door left-hand swing -- Includes door closer, cam lift hinges (one spring loaded), NL9800 deadbolt key/padlock handle with inside release, magnetic gasket, heater wire, double sweep gasket, LED vapor proof light, Heated Air Vent (standard on all freezer compartments) and NL508 combination digital thermometer and switch w/pilot light. (1) Model NL708 High/Low Digital Alarm And Light Management System Installed In Door Panel With Digital Readout -Sounds On Rise Or Fall Of Temperature (In Lieu Of Standard NL508 Combination Digital Thermometer And Switch With Pilot Light) (1) Motion Sensor For NL708 Alarm (Flush Or Surface Mount Style), Kason 1901 Light Activator Installed On Interior Door Frame (1) Third Hinge, Cam Lift (1) 36" Stainless Steel With Floor Threshold (14 Gauge Stainless Steel) (6) Chrome-Kote Shelving 4' 0" x 5' 4" x 2' 0" x 3 tiers. (1) Chrome-Kote Shelving 3' 0" x 5' 4" x 2' 0" x 3 tiers. Refrigeration is "sized" for holding product only; that is; our calculation is based on product entering at the same temperature as the desired temperature of this walk-in. If you feel that this is insufficient, please advise. (1) LAWD200RL4-#BYH -10° F Operation, Low Temperature, Air Cooled, R -404A, Defrost Timer, Remote Fast -Trak cULus Refrigeration System, Pre -Assembled, Pre -Piped, With Hand Valves For Field Piping, Welded Hermetic , Low Profile Unit Cooler, Meets CEC Requirements, 208/230-1-60 Electrical With Flip Up All Weather Hood And -20 Degree Ambient Controls. Condensing Unit Rack Overall Size Is 36.5 Inches Wide, 37.25 Inches Long And 22 Inches High. Unit Cooler Overall Size Is 15 Inches Wide, 45.5 Inches Long And 15.25 Inches High. Condensing Unit, 208/230-1-60 Electrical Requirements Are 23.1 Minimum Circuit AMPS And 35 Maximum Fuse Size. Unit Cooler, 208/230-1-60 Electrical Requirements Are 8.7 Minimum Circuit AMPS And 15 Maximum Fuse Size. 4.49 EER Rating. ( system capacity 7726 BTU's/hour at 100.0°F ambient temperature. ) Calculated load for Freezer (-10.0°F) is 5299 BTU's/hour calculated from 100 °F ambient temperature, 0' elevation, 70 °F floor temperature, 9.26 minutes open door time per 24 hrs for(1) 36.00" X 78.00" walk -indoor opening into 100.00 °F ambient, 1.5 Watts per square foot lighting operating 10 hours per day, 0.0585 occupants working 10 hours per day. All calculations are based on data supplied by ASHRAE publications. (1) 200 To 225 Series - Optional Five Year Extended Compressor Warranty (1) 18 Month Labor/Service Warranty Other Walk -In Accessories: (2) 3" x 3" x 8' 7" Angle Trim Strips 040 Stucco Aluminum (1) Set of Standard Closure Panels 1' high x 31' long 040 Stucco Aluminum With floor walk-in recessed in 4" pit. 'SIT :o` `'r -D FOR: OP: 0 [V73clianical 2/Electrical C'i'lumbing C'Gas Piping City of Tukwila EUILDING DIVISION Construction Approvals: NSF Approved, cULus and CSA Electrical, UL Flame Spread -25 and ULC Flame Spread -50 in accordance with ASTME-84. To comply with the US Energy Independence & Security Act of 2007, all walk-in doors opening into the ambient (indoors or outdoors) are required to have a method for minimizing infiltration when the doors are open. All Nor -Lake walk-in doors will include a spring hinge to comply with this standard by 1-1-09, however; to further minimize infiltration, Nor -Lake recommends the use of a strip curtain or strip door for all exterior doors. NOTE: Indoor walk-in(s) must be in an environmentally controlled space. Relative Humidity should be kept between 30%-60%, maintaining a Dew Point of 50° F or Tess. Quotation is subject to change upon receipt of detailed specifications and/or refrigeration load information. Refrigeration sizing is based on maximum line runs of 100 feet per system. NOTE: Walk -Ins sold into the state of California may require structural engineered drawings for seismic review. If required, Nor -Lake can provide the required drawings and structural support. Please contact Nor -Lake for lead time and pricing to meet this requirement. Local Codes: Walk -Ins may need engineered drawings or special construction to meet local code approvals for rain, wind, seismic, and snow load approvals. If required, please contact Nor -Lake for lead time and pricing to meet these requirements. This walk-in has been quoted with very incomplete and conflicting specifications. Nor -Lake, Inc. is not responsible for discrepancies between this quote and the complete specifications until the complete specification has been received and reviewed by Nor -Lake, Inc. Closure panels quoted as 1' high, please verify prior to order Verify all dimensions prior to order; quoted per scaled drawing in lieu of written specifications Floor finish was not specified, quoted with Nor -Lake standard of smooth aluminum Height was not specified, quoted as 7' 7" high Delivery and Installation Not Included In This Quotation Shelving is quoted as 64" high in lieu of 66" high Quotation is subject to change upon receipt of detailed specifications and/or refrigeration load information. M17- 0107 CITY OF TUKWILA AUG 10 2017 PERMIT CENTER NORLAKE, -SINCE 1947- 727 SECOND STREET, HUDSON, WI. 54016 (715) 386-2323 or (866) A STANDEX COMPANY N.S.F. FOAMED -IN-PLACE FINELINE WALK-IN FREEZER WITH FLOOR SMOOTH ALUMINUM 13'x9'x7'7" CUSTOMER: PROJECT: Tukwila School District Cascade View ES A MINIMUM OF 2" CLEARANCE MUST BE ALLOWED AT ANY POINT WHERE THE WALK-IN IS ERECTED NEXT TO AN EXISTING BUILDING WALL. ALL PANELS ARE FOAMED -IN-PLACE WITH HFC 245fa, CFC FREE POLYURETHANE INSULATION, ZERO OZONE -DEPLETION. NOTE: INDOOR WALK-IN(S) MUST BE IN AN ENVIRONMENTALLY CONTROLLED SPACE. RELATIVE HUMIDITY SHOULD BE KEPT BETWEEN 30% - 60%, MAINTAINING A DEW POINT OF 50°F OR LESS. PLEASE RETURN THE APPROVED DRAWINGS AS SOON AS POSSIBLE TO PREVENT ANY DELAY IN FABRICATION. APPROVED APPROVED AS NOTED NOT APPROVED -RESUBMIT SIGNED DATE IMPORTANT: CHANGES MADE AFTER THE PRINT APPROVAL MAY INVOLVE ADDITIONAL CHARGES AND THE POSSIBILITY OF A REVISED SHIPPING DATE NO. DATE BY DATE: 6/21/17 SCALE: 1/2" = 1' DRN. BY: KB MSR APP APP. BY: D289 EVI DE AP J ity of Tukwila BUILDING DIVISION WED FOR MPLIANCE ROVED 17 2017 1 j' 1 2'-4" rBUJ T L_ 40x24x3 n c� 40x24x3 e.1 40x24x3 U N M n (-10.0°F) 7'7"high With Floor M • 1 'J L 'A"x3'0"x3 WITT SE26-928-DE UNIT COOLER 208-230/60/1 8.7 AMPS Freezer -, CV 4'0"x24"x3 I U M �� U 4'0"x24"x3 n t� UJ 4'0"x24"x3 n1 115/60/1 1.37 Amps 115/60/1 0.04 Amps HAV L� V///////////////////////////////////////// .//////////////////A ti 7- / -10° FREEZER WITH FLOOR SMOOTH ALUMINUM FINISH STANDARD CLOSURE PANELS EXTENDING ABOVE THE WALK-IN TO THE CEILING (ADVISE REQUIRED HEIGHT) NL708 ALARM/ LIGHT MANA3ER Lu ti 4 w • • • a■ . •.• EXTERIOR DOOR HEATER WIR INTERIOR FINISHED FLOOR MUST BE SWEEP TRANSIT LEVEL GASKET AND SMOOTH /S/S THRESHOLD VIEW -A- PARTITION WALL ��(IF APPLICABLE) VAPOR BARRIER: 6 MIL POLYETHYLENE OR 30 LBS. ASPHALT FELT OR HOT ASPHALT GROUT FILL .;* 411 .d"4•. • •••d..! • • 4' •• • . • 4 . -• •• . • - A d • . • . 44 d.• 3"x3" ANGLE TRIM STRIP STD. WITH FLOOR DETAIL IN A 4" RECESS . 4. ; . • . 4' • e . . • • 4 •• d. 4" MIN. SUB SLAB DETAIL 007C BD 8/19/02 DISTANCE ABOVE WALK-IN BUILDING CEILING 3/4" #8 SIS S.M.S. APPROX. 14" APART WALK-IN CLOSURE PANEL OVERLAP ON SIDE OF WALK-IN STANDARD CLOSURE PANEL DETAIL OPTIONAL FLASHING BY G.C.; FLASHING FROM BUILDING OVER TRIM AND MEMBRANE ROOF. FLASHING(by G.C.) CUT INTO BUILDING AND FASTENED BY GENERAL CONTRACTOR. MEMBRANE ROOF MATERIAL TRIM BY NOR LAKE DETAIL 029A BD 5/20/94 4 .12 WALK-IN COOLER/FREEZER 1 2" MAXIMUM — AIR SPACE (ELEVATION VIEW) WALK-IN MEMBRANE ROOF TRIM (1) LAWD200RL4-#BYH REMOTE REFRIGERATION SYSTEM R -404A, AIR COOLED, LOW TEMPERATURE 208-230/60/1 CONDENSING UNIT MCA 23.1, MAX FUSE 35, 352 LBS. UL APPROVED FLIP UP ALL WEATHER HOOD BUILDING DETAIL 040B DRAWN 8/19/02 REVISION 2/26/07 REVISION 8/16/10 SPECIFICATIONS D28946 (QUOTE NUMBER NL1755714SO-A) Nor -Lake is registered by UL to ISO 9001-2008. California State Contractor License #940932. (1) Nor -Lake FINELINE Walk -In Freezer 13' 0" long, 9' 0" wide, 7' 7" high. Finishes: 040 Smooth Aluminum - Interior wall, Interior ceiling 26 Gauge Corrosion Resistant Stucco Embossed Coated Steel - Exterior wall 040 Stucco Aluminum - Exposed wall, Exterior door frame, Exterior door 26 Gauge Smooth Galvanized - Ceiling topside, Floor bottomside .100 Smooth Aluminum - Interior floor REVISIONS No changes shall he made. to the scope of work Withol_:i prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees r • 1 FILE L^iPY Permit NO. IVII��\O- Plan Plan roview c,; ;..rov ; is subjoct to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: B Y� Date: ch -1C f City of Tukwila BUILDING DIVISION Outdoor Walk -In includes Flat White Membrane Roof With Trim — 45 Lbs./Sq. Ft. Ceiling Load Capacity Minimum. . (1) 36" X 78" Walk -In Door left-hand swing -- Includes door closer, cam lift hinges (one spring loaded), NL9800 deadbolt key/padlock handle with inside release, magnetic gasket, heater wire, double sweep gasket, LED vapor proof light, Heated Air Vent (standard on all freezer compartments) and NL508 combination digital thermometer and switch w/pilot light. (1) Model NL708 High/Low Digital Alarm And Light Management System Installed In Door Panel With Digital Readout -Sounds On Rise Or Fall Of Temperature (In Lieu Of Standard NL508 Combination Digital Thermometer And Switch With Pilot Light) (1) Motion Sensor For NL708 Alarm (Flush Or Surface Mount Style), Kason 1901 Light Activator Installed On Interior Door Frame (1) Third Hinge, Cam Lift (1) 36" Stainless Steel With Floor Threshold (14 Gauge Stainless Steel) (6) Chrome-Kote Shelving 4' 0" x 5' 4" x 2' 0" x 3 tiers. (1) Chrome-Kote Shelving 3' 0" x 5' 4" x 2' 0" x 3 tiers. Refrigeration is "sized" for holding product only; that is; our calculation is based on product entering at the same temperature as the desired temperature of this walk-in. If you feel that this is insufficient, please advise. (1) LAWD200RL4-#BYH -10° F Operation, Low Temperature, Air Cooled, R -404A, Defrost Timer, Remote Fast -Trak cULus Refrigeration System, Pre -Assembled, Pre -Piped, With Hand Valves For Field Piping, Welded Hermetic , Low Profile Unit Cooler, Meets CEC Requirements, 208/230-1-60 Electrical With Flip Up All Weather Hood And -20 Degree Ambient Controls. Condensing Unit Rack Overall Size Is 36.5 Inches Wide, 37.25 Inches Long And 22 Inches High. Unit Cooler Overall Size Is 15 Inches Wide, 45.5 Inches Long And 15.25 Inches High. Condensing Unit, 208/230-1-60 Electrical Requirements Are 23.1 Minimum Circuit AMPS And 35 Maximum Fuse Size. Unit Cooler, 208/230-1-60 Electrical Requirements Are 8.7 Minimum Circuit AMPS And 15 Maximum Fuse Size. 4.49 EER Rating. ( system capacity 7726 BTU's/hour at 100.0°F ambient temperature. ) Calculated load for Freezer (-10.0°F) is 5299 BTU's/hour calculated from 100 °F ambient temperature, 0' elevation, 70 °F floor temperature, 9.26 minutes open door time per 24 hrs for(1) 36.00" X 78.00" walk -indoor opening into 100.00 °F ambient, 1.5 Watts per square foot lighting operating 10 hours per day, 0.0585 occupants working 10 hours per day. All calculations are based on data supplied by ASHRAE publications. (1) 200 To 225 Series - Optional Five Year Extended Compressor Warranty (1) 18 Month Labor/Service Warranty Other Walk -In Accessories: (2) 3" x 3" x 8' 7" Angle Trim Strips 040 Stucco Aluminum (1) Set of Standard Closure Panels 1' high x 31' long 040 Stucco Aluminum With floor walk-in recessed in 4" pit. 'SIT :o` `'r -D FOR: OP: 0 [V73clianical 2/Electrical C'i'lumbing C'Gas Piping City of Tukwila EUILDING DIVISION Construction Approvals: NSF Approved, cULus and CSA Electrical, UL Flame Spread -25 and ULC Flame Spread -50 in accordance with ASTME-84. To comply with the US Energy Independence & Security Act of 2007, all walk-in doors opening into the ambient (indoors or outdoors) are required to have a method for minimizing infiltration when the doors are open. All Nor -Lake walk-in doors will include a spring hinge to comply with this standard by 1-1-09, however; to further minimize infiltration, Nor -Lake recommends the use of a strip curtain or strip door for all exterior doors. NOTE: Indoor walk-in(s) must be in an environmentally controlled space. Relative Humidity should be kept between 30%-60%, maintaining a Dew Point of 50° F or Tess. Quotation is subject to change upon receipt of detailed specifications and/or refrigeration load information. Refrigeration sizing is based on maximum line runs of 100 feet per system. NOTE: Walk -Ins sold into the state of California may require structural engineered drawings for seismic review. If required, Nor -Lake can provide the required drawings and structural support. Please contact Nor -Lake for lead time and pricing to meet this requirement. Local Codes: Walk -Ins may need engineered drawings or special construction to meet local code approvals for rain, wind, seismic, and snow load approvals. If required, please contact Nor -Lake for lead time and pricing to meet these requirements. This walk-in has been quoted with very incomplete and conflicting specifications. Nor -Lake, Inc. is not responsible for discrepancies between this quote and the complete specifications until the complete specification has been received and reviewed by Nor -Lake, Inc. Closure panels quoted as 1' high, please verify prior to order Verify all dimensions prior to order; quoted per scaled drawing in lieu of written specifications Floor finish was not specified, quoted with Nor -Lake standard of smooth aluminum Height was not specified, quoted as 7' 7" high Delivery and Installation Not Included In This Quotation Shelving is quoted as 64" high in lieu of 66" high Quotation is subject to change upon receipt of detailed specifications and/or refrigeration load information. M17- 0107 CITY OF TUKWILA AUG 10 2017 PERMIT CENTER NORLAKE, -SINCE 1947- 727 SECOND STREET, HUDSON, WI. 54016 (715) 386-2323 or (866) A STANDEX COMPANY N.S.F. FOAMED -IN-PLACE FINELINE WALK-IN FREEZER WITH FLOOR SMOOTH ALUMINUM 13'x9'x7'7" CUSTOMER: PROJECT: Tukwila School District Cascade View ES A MINIMUM OF 2" CLEARANCE MUST BE ALLOWED AT ANY POINT WHERE THE WALK-IN IS ERECTED NEXT TO AN EXISTING BUILDING WALL. ALL PANELS ARE FOAMED -IN-PLACE WITH HFC 245fa, CFC FREE POLYURETHANE INSULATION, ZERO OZONE -DEPLETION. NOTE: INDOOR WALK-IN(S) MUST BE IN AN ENVIRONMENTALLY CONTROLLED SPACE. RELATIVE HUMIDITY SHOULD BE KEPT BETWEEN 30% - 60%, MAINTAINING A DEW POINT OF 50°F OR LESS. PLEASE RETURN THE APPROVED DRAWINGS AS SOON AS POSSIBLE TO PREVENT ANY DELAY IN FABRICATION. APPROVED APPROVED AS NOTED NOT APPROVED -RESUBMIT SIGNED DATE IMPORTANT: CHANGES MADE AFTER THE PRINT APPROVAL MAY INVOLVE ADDITIONAL CHARGES AND THE POSSIBILITY OF A REVISED SHIPPING DATE NO. DATE BY DATE: 6/21/17 SCALE: 1/2" = 1' DRN. BY: KB MSR APP APP. BY: D289 EVI DE AP J ity of Tukwila BUILDING DIVISION WED FOR MPLIANCE ROVED 17 2017