Loading...
HomeMy WebLinkAboutPermit M17-0109 - RED WING SHOES - HEAT PUMP RTUThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M17-0109 RED WING SHOES 17135 SOUTHCENTER PKWY THE ABOVE MENTIONED Page # DIGITAL Code RECORDS PERMIT FILE INCLUDES Exemption (DR) EXEMPTION LOG THE FOLLOWING REDACTED INFORMATION Brief Explanatory Description StatutelRule Personal Information — The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 55 DR2 Financial Information — RCW 42.56.230(4 5) account numbers, which are exempt from disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. 42.56.230(5) Personal Information — Driver's License. RCW Redactions contain information used to prove RCW DR3 — identity, age, residential address, social security 42.56.230 (7a 42.56.230 (7a & c) number or other personal information required to apply for a driver's license or identicard. & c) Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW DR4 Attorney -Client Privilege — RCW 5.60.060(2)(a); RCW disclosure pursuant to RCW 5.60.060(2)(a), which protects attorney-client privileged 5.60.060(2)(a); RCW 42.56.070(1) communications, and RCW 42.56.070(1), which protects, under the PRA, information exempt or prohibited from disclosure under another statute. 42.56.070(1) RED WING SHOES 17135 SOUTHCENTER PKWY EXPIRED 03/13/18 M17-0109 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049071 Permit Number: M17-0109 17135 SOUTHCENTER PKWY Project Name: RED WING SHOES Issue Date: 9/14/2017 Permit Expires On: 3/13/2018 Owner: Name: Address: KTM GROUP LLC 2810 EASTLAKE AVE E , SEATTLE, WA, 98102 Contact Person: Name: DAWNA PETET Phone: (253) 939-9495 Address: 899 W MAIN ST, AUBURN, WA, 98001 Contractor: Name: IECS INC Phone: (206) 939-9495 Address: PO BOX 19252 , SEATTLE, WA, 98109- 1252 License No: IECS***044QL Expiration Date: 11/20/2018 Lender: Name: Address: DESCRIPTION OF WORK: REPLACE EXISTINGTRANE MODEL #YSC060A3EHAI GAS RTU WITH A NEW CARRIER MODEL #50KCQA06A HEAT PUMP RTU Valuation of Work: $16,535.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $424.04 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized"Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2014 2014 2014 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development •ermit and agree to the conditions attached to this permit. Signatur Print Name: - (DCl` Wiry( Date: q_11-/-/7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION .0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: - 010? 0-11- 17 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION -7 Sot King Co Assessor's Tax No.: Site Address: 17 ( 3 5 (�-( Pkw n r1 Tenant Name: gQ�X � l n , _S PROPERTY OWNER Name: kilr /mina p Address: 9 s Ip gas*? 'Iv{ i - City: eta State:'f 4 j/4 ZiP:6 73/0a CONTACT PERSON — person receiving all project communication Name: no,r L T;I�- Low � Address: Sen 1,0 ` }ilsLivi s+__ , Zip:9 City: 1J114(i\._ State: Mx_aot) I Phone: (g5. 'Q.3_9l : (253- 939,_ q24-0 Email:Ad Lti mit 1 5,ea44-tszoli cko hd nd 1 Suite Number: New Tenant: A 64610 7 / Floor: 0 Yes 1FL.No MECHANICAL CONTRACTOR INFORMATION Company Name: /�,J ,���� /�%�/� (5-M 'WI ale d I cd Address: gqq too `, _f 'l r ` . (y�� City: A. i b r(o State: f 3j Zip: gOCX) Phone:a55'" l-�`7 '" 9 (ti ax:t2t3' q -- 9,26 0 l -�% Contr Re o.: Exp Date: i i hafts Tukwila Business License No.:Auk509'A947 ( Valuation of project (contractor's bid price): $ / W) 51b5, 0 0 ' �1 Describe the scope.of work in detail: R-Q,��QCJZ_ e ii t i�'C�. - . V nbo J * y5 0..010 0 ' i + b i 1 G", R'T u 1.0{"d1'1t"l ac Ale V WL ea�rno c s.k 50 kc a l o (a 0 14 - wn RTS.. Use: Residential: New 0 Replacement 0 Commercial: New 0 Replacement Fuel Type: Electric �Q Gas ❑ Other: HAAppliatio=Worms-Applicata= On Late \2016 Applications\Mechanical Permit Application Revised 1-4-16.doex Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Fumace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) N 0121-1- um,l, 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 *Daytim District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE;SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD : G OWNER ORA ? O ' .ZED AG NT: Signatur Print Name: Mailing Address: QLon1 '� ► `¢ T ` -42- fA lQ , elephone: gg9I Ire (s -. /944tAlily HAApplicationa\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Date: SID State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT I QUANTITY PermitTRAK PAID $424.04 M17-0109 Address: 17135 SOUTHCENTER PKWY Apn: 2623049071 $424.04 MECHANICAL $407.73 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $293.03 PLAN CHECK FEE R000.322.102.00.00 0.00 $81.55 TECHNOLOGY FEE $16.31 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12102 R000.322.900.04.00 0.00 $16.31 $424.04 Date Paid: Friday, August 11, 2017 Paid By: SEATTLE MECHANICAL INC Pay Method: CHECK 12220 Printed: Friday, August 11, 2017 8:57 AM 1 of 1 CRIVSYSTEMS REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1 FILE COPY Permit No. Vt. L <7 i o Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field Copy and conditions is acknow$edget City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: 0 Mechanical El/Electrical Ltumbirg -f4Gas Piping City of Tukwila BUILDING DIVISION RV 1: 2O REVIEWED FOR CODE COMPLIANCE APPROVED AUG 3 0 201? {: City of Tube BUILDING Scope of work Replace existing Trane YSC060A3EHA1 Gas RTU with a new Carrier 5OKCQA06A Heat Pump RTU. EVIEWED *FOR C DE COMPLIANCE APPROVED AUG 3 0 2017 City of Tukwil- IL�ING D!' ON .+� o 1.1 C 00 cn o0 0 c 3 M 3 a et eg 'ERM IT SEi' • Google Earth feet meters 90 3C RECEIVED ITY OF TUKWILA AUG 112017 PATECENTER PATE ; 7/18/2017 Lu1 vvasnington state Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary 2015 Washin.ton State Ene Code Com Project Information lance Forms for Commercial Bulldin s includin• R2 & R3 over 3 stories and all R1 ►i MECH-SUM Revised January 2017 Project Title: (VI 14(5/1 0 v V1L 6E Date Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. A2 Company Name: 5-r Y/J ��,�tcdc%L Company Address: r q AAA.) c\ --r . /A, �vrn ,, k1 • 9 Applicant Name: f RJ �l.i`F Applicant Phone: 253 q3 91- q — For Building Dept. Use riLE Project Description Briefly describe mechanical systems in the text box provided ❑Total Bldg Performance (TBP) This path includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required. :New Building ❑Building Addition ❑Tenant Improvement ❑System Retrofit o System Changes 1 'LAC rui&- 51ro0 G A5 t''AC.k446e v 'Act ,,,_)ert-t » IU Cor► R2 (e-12 0 igelcr ?utA-4 �. Design Load Calculations Mechanical Schedules ❑ Load calculation summary ❑ MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC for is not required. Mechanical Plans)Yf 0 MECH-EQ Forms (TBD) Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, however, include on plans all applicable compliance information listed in MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and fire station occupancies) All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation air in a manner that does not require space conditioning fan operation. Space conditioning fans cycled off when no heating or cooling is required. ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, Exception 1) ❑ Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS (C403.6, Exception 2) ❑ DOAS included in project, although not required (occupancy not office, retail, education, library or fire station) 0 DOAS related allowances included in project: O Prescriptive vertical fenestration maximum area allowance increased to 40% per C402.4.1.4 with 100% of conditioned floor area in building served by DOAS. ❑ Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power HVAC Hydronic Systems fid Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM for. O For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements ano exceptions. ❑ Hydronic chilled water ❑ Hydronic heating water ❑ Water -loop heat pump ❑ Geothermal 'J No hydronic systems C406 Additional Efficiency 0 HonsMe an:gal REVIEWED FOR :ODE COMPLIANCE APPROVED ❑ C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than minimum requirements. All stand alone supply, return, and exhaust fans overlhp must have FEQ 2 71 and must be selected within 10% of maximum total or static pressure. ❑ C406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per 0403.6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. ❑ C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% of annual hot water energy use be provided by heat pump, waste heat recovery or solar water -heating systems. AUG 302017 ' City of Tukwila t/i( T. 0 I 0 7 BUIL'DING DIVISION RECEIVED CITY OF TUKWILA AUG 11 2017 PERMIT CENTER 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 7 ec anica ummary, pg. 2 MECH-SUM State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised 2015 Washington January 2017 Service Water Heating Systems N(A' I Equipment Type (s) ❑ Instantaneous g No service water systems from space heat boiler or • Hot water heating tank(s) ❑ Dedicated boiler Distribution Type (s) ❑ Circulation System • Heat exchange central hot water/steam • On -demand Commissioning Commissioning is required for: per C408.2 shall be performed requirements: of all mechanical heating. Mechanical water heating not required. water heating systems per C408.4 systems regardless of individual equipment capacity. systems in the building do not exceed 240,000 Btu/h commissioning not required. does not exceed 200,000 Btu/h. Service water heating • Mechanical systems • Service !f required, commissioning Exceptions to commissioning Tr -'0. Total output capacity cooling or 300,000 Btu/h for all applicable space conditioning systems system in building • Capacity of largest service systems commissioning Low Energy and Semi -Heated Spaces (Note 6 and 7) Space Type • Location iri Plan(s) - Space(s) Served' Area Served, square feet Heating Capacity;-Btu/h (Note 4) Cooling Capacity, Btu/h (Note 5) Peak Space Conditioning Capacity, Btu/h-sf Compliance Check Notes iii Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. En er 0 if no cooling. Note 6 - Refer to Section C402.1.1 Low Energy Building. 'Walled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/lest Note 7 - Refer to Section C402.1.1.1 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h*sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 1 of 7 Mechanical Permit Plans Checklist 2015 Washington State Energy Code Compliance Forms for MECH-CHK Project Title: Fill this line out on MECH-SUM rcewseu January zui r Date 1 /1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required -Must be in permit documents Location in Documents Building Department Notes Equipment - Sizing, Performance and Type C403.1 Exempt process equipment Identify equipment to be used in manufacturing, industrial or commercial processes that do not provide space conditioning; identify provisions applicable to this equipment per C403.1 exception iC403.2.1 Load calculations Provide load calculations performed per ASHRAE Std 183 or equivalent, using design parameters per C302 and Appendix C; include load adjustments to account for energy recovery rL �C, 7 03 2 2 Equipment and system sizing Indicate that output capacities of heating and cooling equipment and systems are no greater than the smallest available equipment size that exceeds the calculated loads; note exceptions taken C403.2.3 C403.2.3.2 C403.2.13.1 HVAC equipment performance requirements (efficiency) Provide equipment schedules on plans or complete MECH-EQ forms indicating type, capacity, rated and WSEC minimum efficiencies for all heating and cooling equipment; include supply and OSA cfms and operating hours for all air systems; identify heating and cooling equipment that does not have a corresponding WSEC minimum efficiency (manufacturer rated) C405.8 0403.2.14 Electric motor efficiency List all motors 2 1/12 hp (that are not integral to a rated piece of equipment) in the mechanical or electrical equipment schedules on plans; indicate hp, rpm, number of poles and rated efficiency, or exception applied For fractional hp motors (1/12 - 1 hp), indicate whether they are an electronically commutated motor, have rated efficiency of at least 70%, or exception taken For all HVAC fan systems that provide heating and / or cooling, provide system total nameplate hp in MECH-FANSYS-SUM form C403.2.11.1 Fan power limitation For all applicable HVAC systems with total fan motor hp > 5hp, verify fan system motor hp or bhp complies with fan power limits per equations in Table C403.2.11.1(1), provide MECH- FANSYS form for each system 0403.2.11.2 Motor nameplate hp For all applicable HVAC systems with total fan motor hp > 5hp, indicate fan motors specified are the smallest available motor hp size greater than fan bhp, note exceptions taken 0403.2.11.3 Fan efficiency For all applicable HVAC systems with total fan motor hp > 5hp, identify in equipment schedule all fans required to comply with fan efficiency grade and indicate rated FEG is 2 67, or exception taken; Indicate these fans are sized so total efficiency is within 15% of the fan maximum total efficiency frA.,0403.2.11.4 Nexhaust Group R occupancy fan efficacy For all exhaust fans < 400 cfm in Group R occupancies, indicate in equipment schedule the fan flow rate and efficacy (cfm/watt), or exception taken; refer to Table C403.2.11.4 (CE -57) C403.2.13 Variable flow capacity - fans For fan motors 2 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for an HVAC system refer to HVAC System Controls for additional requirements C403.2.3 Maximum air cooled chiller capacity For chilled water plants and buildings with > 500 tons of cooling capacity, indicate air-cooled chiller capacity is 5 100 tons, or exception taken C403.4 Large capacity cooling systems For buildings with 2 300 tons of cooling capacity, indicate method of multi -stage or variable capacity control (VSD, multiple staged compressors, or max capacity of any single unit < 66% of the total) C403.2.3.1 Non-standard water-cooled centrifugal chillers For water-cooled centrifugal chillers not designed for operation at standard conditions, provide calculations documenting maximum full load and part load rated equipment performance requirements C403.2.13.1 C403.4.3.2 Centrifugal fan open -circuit cooling towers For open -circuit centrifugal fan cooling towers with 2 1,100 gpm capacity, indicate cooling towers comply with efficiency requirements for axial fan open circuit cooling towers C403.4.2 Large For single boilers with > 500,000 Btu/h capacity, indicate multi -stage or modulating bumer C403.4.2.5 capacity boiler systems For boiler system (single or multiple) with > 1,000,000 Btu/h capacity, indicate tumdown ratio per Table C403.4.2.5 and method (multiple single input boilers, modulating boilers, or combination) 0403.2.13 Variable flow capacity - pumps For pump motors 2 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for a hydronlc system refer to Hydronic System Controls for additional requirements C403.2.3 Gas and oil -fired forced air fumace and unit heaters For forced air furnaces with capacity 2 225,000 Btu/h and all unit heaters, indicate in equipment schedule intermittent ignition or IID, flue or draft damper, and rated jacket loss C403.2.4.8 Combustion heating equipment For combustion heating equipment with output capacity > 225,000 Btu/h, indicate modulating or staged combustion control C403.2.3.3 Packaged electric heating / cooling equipment Verify all packaged electric equipment with > 6,000 Btu/h cooling capacity and any amount of heating is a heat pump; include in equipment schedules C403.2.12 Heating outside a building Indicate systems providing heating in non -enclosed outdoor occupied spaces are radiant systems; refer to HVAC System Controls for additional requirements C403.2.7.1 Kitchen exhaust hoods Indicate on plans the type, duty and exhaust air rate of each kitchen hood, refer to HVAC System Controls for additional requirements �' C403.2.4.3 Outdoor supply air, exhaust Indicate and relief dampers rating, locations of OSA intake, and exhaust and relief outlet dampers on plans; indicate whether dampers are Class 1 motorized, or gravity and exception taken (include leakage cfm/sf); refer to HVAC System Controls for additional requirements for OSA dampers C403.2.4.3 Indicate Retum air dampers dampers eligible locations of retum air dampers that are Integral to economizer operation; verify are motorized; indicate whether dampers are Class 1, or within packaged equipment for leakage rating exception (include leakage rating, cfm/sf) 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 2 of 7 Mechanical Permit Plans Checklist 2015 Washington State Energy Code Compliance F MECH-CHK Project Title: Fill this Zine out on MECH-SUM rcevisea January zui t Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code ProvisionInformation Required -Must be in permit documents Location in Documents Building Department Notes �I 0403.2.4.3 Stairway and shaft vent dampers Indicate location of stairway and shaft vent dampers on plans; verify dampers are Class 1 motorized; refer to HVAC System Controls for additional requirements C403.2.4.4 Zone isolation dampers For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; Identify isolation zone areas on plans and locations of associated isolation dampers in HVAC distribution system; refer to HVAC System Controls for additional requirements C403.2.3.4 Humidification For cooling systems with humidification equipment that are also required to have air economizer, indicate humidifier is adiabatic (direct evaporative or fog atomization), or exception taken Add i tonal Efficiency Package Option, More Efficient HVAC Equipment & Fan Performance - Mu comply with all 3 provisions to be eligible C406.2.1 C403.2.3 HVAC system selection To comply with additional efficiency package option, calculate the percentage of heating and cooling equipment in the project (based on output capacity) that do not have a corresponding WSEC listed efficiency; shall be less than 10% to comply C406.2.2 C403.2.3 Minimum equipment efficiency To comply with additional efficiency package option, indicate that all listed heating and cooling equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% C406.2.3 0403.2.11.3 Minimum fan efficiency To comply with additional efficiency package option, indicate rated FEG of stand alone fans is z 71; indicate these fans are sized so the fan efficiency at design conditions Is within 10% of the maximum total or static efficiency HVC System Controls Indicate locations of thermostatic and humidity control devices and the zones they serve on plans, including perimeter system zones C403.2.4.1 Thermostatic controls (thermostats and humidistats) Where adjacent (neighboring) zones are controlled by separate thermostats (including perimeter systems used to offset heat gain or loss), and are connected by permanent openings > 10% of either zone sf area, indicate controls configured to prevent adjacent zones from operating in conflicting modes (one in heat, other in cool); applies to adjacent perimeter zones, adjacent nonperimeter zones, and adjacent perimeter and nonperimeter zones If applying Exception 2 to nonperimeter zones adjacent to perimeter zones, Indicate that setpoints and deadband settings In these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature in that zone is 5°F higher than the adjacent perimeter zone temperature In heating Et? 0403.2.4.1.1 Heat pump supplementary heat Indicate staged heating operation with compression as the first stage of heating and supplemental heating controlled with outdoor lockout temperature set to 40°F or less er-L C 0403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that control both heating and cooling ye C403.2.4.1.3 Setpoint overlap restriction (thermostats) If separate heating and cooling systems with separate thermostatic control devices are used to serve a zone, indicate locations of both thermostatic control devices and the zone they serve on plans Indicate a limit switch, mechanical stop or DDC control with programming to prevent simultaneous heating and cooling C403.2.4.2 C403.2.4.2.1 C403.2.4.2.2 Automatic setback and shutdown Indicate zone thermostatic controls configured with required automatic setback and manual override functions, setback temperatures, and control method (automatic time clock or programmable controls); note exceptions taken Ol��j 1 0403.2.4.2.3 Automatic (optimum) start Indicate system controls that adjust equipment start time required to bring each area served up to design temperature just prior to scheduled occupancy i] FS (V - C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment operation; not including economizer cooling, night flush or IMC required OSA / exhaust • F % W / C403.2.4.3 Stairway and shaft vent P Indicate method of activation of stairway and shaft vent dampers (fire alarm or interruption of power) C403.2.4.4 Zone isolation controls For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; indicate controls that allow for independent space conditioning of isolation zones; or exception taken C403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off heating system when area served is unoccupied C403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation is falling, and when outdoor air temperature exceeds 40°F C403.2.4.6 Freeze protection system controls Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F, or conditions protect fluid from freezing C403.2.4.9 Group R1 hotel / motel guest rooms For hotels and motels with over 50 guest rooms, indicate automatic controls serving guest rooms that are capable of setback (heating) and set-up (cooling) of temperature setpoint by at least 5°F; Indicate control method - activated by room entry or occupancy sensor 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 3 of 7 Mechanical Permit Plans Checklist 2015 Washington State Energy Code Compliance Forms for Commercial Buildings Including R2 MECH-CHK _..._ _._. - _._..___.._....... Project 710e: Fill this line out onMECHSUM nov,aCu JaiIualy CU 1r Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code ProvisionInformation Required -Must be in permit documents Location in Documents Building Department Notes Q ',1i/ C403.2.4.10 0403.2.4.11 Group R2 / R3 dwelling units, Group R2 sleeping units For primary space conditioning system, indicate 5-2 programmable thermostats capable of two setback periods per day; for all thermostats indicate purpose (heating only, cooling only, or both), required temperature range and at minimum a 10°F deadband; or exception taken Indicate method of ventilation air delivery (natural or mechanical) for each zone C403.2.6 0403.2.11.4 Ventilation If mechanically delivered, indicate that systems are configured to provide not more than 150% of, but at least the minimum required volume of outdoor air to each zone per IMC, ASHRAE 62.1 or other applicable code (WAC, OSHA, etc); or exception taken If delivered via natural ventilation, identify required elements per IMC including minimum openable area to the outdoors or qualifying adjoining spaces C403.2.6.2 Demand controlled ventilation Identify spaces > 500 sf with occupant load > 25 people/1,000 sf per IMC; for each space indicate whether It is served by an HVAC system with total design OSA > 3,000 cfm, and / or the system has airside economizer or automatic modulating OSA dampen indicate OSA controls are configured to provide demand controlled ventilation or provide supporting documentation for applied exception C403.2.6.3 Occupancy sensors For gyms, classrooms, auditoriums and conference rooms > 500 sf, indicate occupancy -based OSA control when space is unoccupied and method (closes OSA damper or shuts -off equipment); or alternate means provided to automatically reduce OSA when space is partially occupied C403.2.6.4 C403.2.6.4.1 Enclosed loading dock ventilation For enclosed loading docks, indicate ventilation / exhaust system method of activation (gas detection system for CO and NO2, or occupancy sensors), and control method (staged or modulating) C403.2.6.4 C403.2.6.4.2 Enclosed parking garage ventilation For enclosed parking garages, indicate ventilation / exhaust system activated by gas detection system for CO and NO2, and control method (staged or modulating); or exception taken C403.2.7.1 Kitchen exhaust hoods Provide calculations that show a balanced accounting of total kitchen exhaust (include all hoods) with % of: supply air, transfer air from adjacent spaces, and make-up air, if applicable, indicate that direct make-up air to each hood does not exceed 10% of hood exhaust For kitchens with total hood exhaust exceeding 2,000 cfm, indicate exhaust air rate per Table C403.2.7.1 and compliance method (DCV, energy recovery, or transfer air that would otherwise be exhausted) C403.2.7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements C403.2.13 Variable flow capacity - HVAC system fans For HVAC fan motors a 7.5 hp, indicate method of variable flow control (VSD, or equivalent control method that reduces design air volume by 50% at 1/3 static design pressure); note exception taken C403.3.1 DX air handler variable cooling control (Under Integrated For DX air handlers with economizer and cooling capacity a 65,000 Btu/h, indicate number of cooling stages provided and method (multiple compressors and / or variable speed compressors); indicate minimum displacement (capacity reduction) as % of full load Economizer) Indicate control method (cooling capacity controlled in response to space temperature, space temperature controlled by modulating supply airflow, or both) For DX air handling units with cooling capacity z 65,000 Btu/h and evaporative and chilled water air handling units with fan 2 0.25 hp, indicate whether system is single zone or multiple zone and related control method (cooling capacity controlled in response to space temperature, space temperature is controlled by modulating supply airflow, or both) C403.2.11.5 Fan airflow control For mechanical cooling systems (includes DX and chilled water coils) that control cooling capacity in response to space temperature - Provide a minimum of two stages of fan control; indicate minimum fan speed is 5 66% of full speed drawing 5 40% of full speed fan power during periods of low cooling or ventilation only For other mechanical cooling systems (includes DX and chilled water coils) that control space temperature by modulating airflow (in lieu of, or in addition to, controlling capacity in response to space temperature) - Provide fan controls for modulating supply airflow; indicate minimum fan speed is 5 50% of full speed drawing 5 30% of full speed fan power during periods of low cooling or ventilation only; or exception taken C403.2.4.12 DDC system capabilities Provide central and zone level DDC controls as required based on system application, capacity or size thresholds and other qualification per Table C403.2.4.12.1 Identify all DDC system input / output control points; indicate capability for trending and graphical display Du ing Systems C403.2.8.1 Duct Indicate on plans that all ductwork is constructed and sealed per IMC C403.2.8.3 construction For OSA ductwork, also indicate on plans that ductwork meets air leakage requirements per C402.5 and vapor retarder requirements per the IBC C403.2.8.3 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans C403.2.8.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 4 of 7 Mechanical Permit Plans Checklist 2015 Washington State Energy Code Compliance F MECH-CHK Project Title: Fill this line out on MECH-SUM Kevised January 2017 Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code ProvisionLocation Information Required - Must be in permit documents in Documents Building Department Notes For supply and retum ductwork located In unconditioned space or outdoors, indicate R -value of insulation on ductwork on plans; identify climate zone; note exceptions taken I pr C403.2.8.1 C403.2.8.2 For supply ductwork located in conditioned space, identify if design supply temperature is < Duct insulation 55°F or> 105°F and indicate R -value of insulation on this ductwork on plans; note exception taken i For OSA ductwork, shafts and plenums, indicate R -value of insulation on these elements on _plans per Table C402.1.3 for steel -framed walls; note exception taken Pipin; Systems C403.2.9 Piping insulation Indicate design temperature range of fluid conveyed in piping and thickness of insulation (in inches) on hydronic piping plans; or exception taken C403.2.9.1 Piping insulation exposed to weather Indicate method of protection of pipe insulation from damage / degradation on hydronic piping plans Econlmizers Identify in equipment schedules on plans or in MECH-EQ forms at cooling systems requiring air economizer controls C403.3 Air economizer required Provide MECH-ECONO form indicating systems utilizing air economizer exceptions, including those with water -side economizer In lieu of air economizer, indicate on plans eligible exception(s) taken and measures to comply with exception(s) C403.3.1 Integrated economizer operation - air and water Indicate air and water -side economizers are configured for partial cooling operation even where additional mechanical cooling is required to meet the load C403.3.2 Economizer heating system impact - air and water Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation wCiS C403.3.3.1 Air economizer capacity Indicate modulating OSA and return air dampers are configured to provide up to 100% OSA for cooling 1E5 C403.3.1 0403.3.3.2 Integrated air economizer Verify mechanical cooling controls are interlocked with air economizer controls so the outside air damper remains in 100% open position when mechanical cooling is also required to meet the cooling load, until the leaving air temperature is < 45°F For systems with cooling capacity a 65,000 Btu/h, verify that control of economizer dampers is not based only on mixed air temperature; or exception taken b IA. C403.3.3.3 controls Air economizer high limit Indicate high limit shut-off control method and required high limit per Table 0403.3.3.3 C403.3.4.1 Water economizer capacity For eligible systems where water -side economizer may be provided in lieu of air economizer, indicate system is capable of 100% design cooling capacity at 50°F db / 45°F wb OSA temperatures C403.3.4.2 Water economizer maximum pressure drop Indicate pressure drop across precooling coils and heat exchangers in water economizer system do not exceed pressure drop limit C403.3.1 DX air handling equipment control For DX air handlers with economizer and cooling capacity a 65,000 Btu/h, refer to HVAC System Controls for requirements C403.2.4.7 DX equipment economizer fault detection and diagnostics For DX air handlers with economizer and cooling capacity a 54,000 Btu/h, provide a fault detection and diagnostics (FDD) system to monitor economizer system operation and report faults Systems Requiring Energy Recovery Energy recovery (ER) - For systems with design OSA > 5,000 cfm, or design suppy air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations C403.5.1 ventilation / exhaust systems For rooms served by multiple systems with aggregate design OSA > 5,000 cfm, or aggregate design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations Indicate ER rated effectiveness that increases OSA enthalpy by z 50% based on delta between OSA and retum air enthalpies at design conditions C403.2.7.2 Laboratory exhaust systems (energy recovery) For buildings with total lab exhaust > 5,000 cfm, indicate method of energy recovery used to precondition laboratory make-up air, ER effectiveness (min 25°F); or alternative method per exception (VAV exhaust, semi -conditioned makeup, or CERM calculation) C404.10.4 (under C404.11) Pools and permanent spas exhaust systems For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken (energy recovery) Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by a 36°F 0403.5.2 Energy recovery - For buildings with on-site steam heating systems, indicate condensate water ER • steam condensate systems For buildings that use off-site generated steam where condensate Is not retumed to the source, indicate on-site condensate water ER 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and at R1 - Page 5 of 7 Meclihnical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for _ — ........... - ........... ...... ....... Protect Title: Fill this line out on MECH-SUM rceviseu January tvr r Date 1/1/2015 the following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code ProvisionInformation Required - Must be !n permit documents Location in Documents Building Department Notes ij IA' 0403.5.3 Energy recovery - For buildings with food service, meat or deli departments that have 2 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy (service water heating, space heating, or dehumidification reheating) cooler / freezer condensers For buildings with 2 40,000 sf conditioned floor area and with z 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy for service water heating and also for space heating, or dehumidification reheating C403.5.4 Energy recovery - condenser systems For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and design service hot water load > 250,000 Btu/h, indicate condenser ER to pre -heat service water, or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). Hydronic System Controls 0403.2.13 C403.4.2.7 Variable flow control - hydronic system pumps For hydronic system pump motors z 7.5 hp, indicate method of variable flow control (VSD or equivalent method that requires z 30% design wattage at 50% design fluid flow); note exception taken Identify whether hydronic coils have DDC controls and associated manner of pump speed control (differential pressure, zone hydronic demand, etc) For boilers that provide building heating, indicate controls that provide heating water temperature setback based on outdoor temperature C403.2.5 C403.4.2.4 Hydropic system setback and part load controls For heating and chilled water systems 2 300,000 Btu/h, indicate systems are configured to automatically reset supply water temperature based upon demand; or exception taken. If system pump motor hp a 3 hp, also indicate controls automatically reduce flow by a 50%. For chilled water systems (2 300,000 Btu/h, pump motor hp 2 3 hp) that serve water-cooled unitary air conditioners, indicate VSD or staged pumps in chilled water system and heat rejection loop that reduce pump flow so that one control valve is nearly wkie open, or to maintain a minimum differential pressure; or exception taken C403.4.2 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers C403.4.6 Hot gas bypass limitation For cooling equipment with hot gas bypass, provide either multiple step unloading or continuous capacity modulation; indicate bypass capacity per Table C403.4.6 C403.4.2.2 Two -pipe changeover systems Indicate changeover deadband (min 15°F), heating / cooling mode scheduling and changeover temperature range (limit 30°F) C403.4.2.6 Chiller / boiler plant pump isolation Indicate controls are configured to automatically reduce overall plant flow and shut-off flow through individual chillers and boilers when not in use C403.2.13.1.1 C403.4.3.1.1 Heat rejection equipment - variable flow control For cooling towers with fan motors 2 7.5 hp, indicate VSD and method to adjust fan speed (adjusted based on leaving fluid temperature or condenser temperature / pressure of heat rejection device) C403.4.3.1.2 For multiple -cell heat rejection equipment with VSD, indicate controls that ramp all fans in unison C403.4.3.3 Heat rejection equipment - cooling tower flow tumdown Indicate open -circuit cooling towers with multiple pumps or VSD control are designed so all cells can be run in parallel C403.4.2.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide minimum 20°F water supply temperature deadband between heat rejection and heat addition modes; or exception taken C403.4.2.3.2.1 Water loop heat pump - heat rejection equipment, Zone 4 Indicate type of cooling tower (open- or closed-circuit) in equipment schedule; indicate method used to limit system heat loss when heat rejection is not needed C403.4.2.3.2.2 Water loop heat pump - heat rejection equipment, Zone 5 For open- or closed-circuit cooling towers, provide a heat exchanger that separates the coolin tower and heat pump loop g C403.4.2.3.3 Water loop heat pump - isolation valves For hydronic heat pump systems with total system power> 10 hp, indicate 2 -way isolation valves on each heat pump and variable flow system control Dedicated Outdoor Air Systems (DOAS) - Option through 6/30/16, Prescriptive 7/1/2016 C403.6 C403.6.3 Dedicated outdoor air systems For buildings with office, retail, education, library and fire station spaces, identify these spaces on plans; indicate that ventilation air in each occupied space is provided via a DOAS system; or document compliance with C403.6.3 Impracticality; or exception taken (buildings complying with C402.4.1.4 or C406.6 may not utilize exceptions) C403.6.1 Energy recovery ventilation with DOAS For all DOAS systems, indicate exhaust air ER method; or exception taken with supporting calculations. Indicate ER rated effectiveness that increases OSA enthalpy by t 50% based on delta between OSA and retum air enthalpies at design conditions. C403.6.2 Heating / cooling system controls with DOAS Indicate equipment associated with the delivery of zone level heating and cooling (fans, hydronic pumps, primary air dampers, etc) are configured to shut off, and central equipment is configured to tum down, when there is no call for heating or cooling in the zone they serve if applying Exception to heating / cooling fans used for air mixing in the space during deadband periods, include fan watts per cfm in equipment schedule 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 6 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buil in - _ - - - - -- - --- -- -..- - Project Title: . Fill this line out on MECH-SUM , wa.,oau uanua 7 c� i t Date 1/1/2015 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code ProvisionInformation Required -Must be in permit documents location in Documents Building Department Notes Y g ( C402.4.1.4 C403.6 Increased prescriptive maximum vertical fenestration area with DOAS Indicate that all occupied, conditioned spaces are served by a DOAS per C403.6 Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) C406.6 Building provided with DOAS To comply with additional efficiency package option, indicate that 90% or more of all occupied, conditioned spaces are served by a DOAS per C403.6 Multiple Zone Air Systems NfA f� C403.4.4 Air systems serving multiple zones Identify supply air systems serving multiple zones and the zones they serve on plans; indicate whether system is VAV and method of primary air control; or provide supporting documentation for applied exception to VAV Provide equipment schedules on plans or MECH-EQ form that list all VAV air terminals and types C403.4.4 VAV systems serving multiple zones For each air terminal include: maximum airflow rates for primary supply air during zone peak heating and zone peak cooling; maximum airflow during reheating, recooling or mixing; minimum airflow rate to maintain required ventilation, and the basis for these values; if IMC or ASHRAE 62.1 multiple zone equation is basis for minimum flow rates, provide calculation on plans C403.4.4.1 Single duct VAV terminal units Indicate single duct terminal units are configured to reduce primary supply air before reheating or recooling C403.4.4.2 Dual duct systems - terminal units For systems with separate warm air and cool air ducts, indicate terminal units are configured to reduce the flow from one duct to minimum before mixing with air from the other duct Indicate locations of duct static pressure sensors on plans; Include at least one sensor per major duct branch; verify controller setpoint pressure at each sensor is 5 1.2 inch w.g. r C403.4.1.1 C403.4.1.2 VAV system static pressure sensors - sensors and DDC set points For systems with zone level DDC, indicate controls are configured to monitor zone damper positions and reset static pressure setpoint based on the zone requiring most pressure; include control logic that automatically detects and generates an alarm if any zone excessively drives reset logic, and allows building operators to exclude zones from reset logic C403.4.4.3 Multiple -zone VAV system ventilation optimization controls For systems with zone level DDC controls, indicate controls are configured to automatically reduce outdoor airflow in response to changes in system ventilation efficiency; or exception taken C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or outdoor air temperature; or exception taken MAiltiple Zone HVAC Systems, High Efficiency VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply with all 16 provisions C403.7, Item 1 Air economizer Indicate system is configured for 100% air economizer operation and complies with all related economizer requirements per C403.3 (without economizer exceptions) C403.7, Item 2 Direct digital controls (DDC) Provide DDC controls for all components of system; identify all DDC system input / output control points; indicate capability for trending and graphical display C403.7, Item 3 Outdoor airflow measurement and reduction For systems with minimum OSA > 2,500 cfm, indicate outdoor airflow monitoring station that measures OSA intake under all load conditions; indicate control sequence that increases or reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency (per C403.4.4.3 without exceptions) or DCV (per C403.2.6.2) C403.7, Item 4 Supply airflow measurement For systems with minimum OSA > 2,500 cfm, Indicate supply airflow monitoring station capable of measuring supply air delivered to VAV terminals under all load conditions C403.7, Item 5 Zone isolation and maximum area served Verify maximum area served by a single HEVAV system is 5 50,000 sf, or one entire floor, whichever is greater, in addition If a system serves > 25,000 sf, that includes areas that are expected to be occupied non -simultaneously, indicate zone isolation controls per C403.2.4.4 C403.7, Item 6 Interior / exterior zone design supply air temperature Verify that VAV terminals serving interior cooling driven loads are sized per design supply air temperature that is 5°F higher than VAV terminals serving exterior zones C403.7, Item 7 Maximum air terminal inlet velocity Identify air terminals with minimum primary airflow setpoints > 50% of maximum setpoint in equipment schedule or MECH-EQ form; indicate air terminal inlet velocity does not exceed 900 fpm C403.7, Item 8 Sequence of operation Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC 36 C403.7, Item9 Maximum allowable system brake horsepower Verify fan system bhp is 5 90% of the bhp limit per Option 2 equation in Table C403.2.11.1(1), provide MECH-FANSYS form for each system C403.7, Item 10 Fan -powered terminal unit motor and control Indicate all series and parallel terminal fans have electronically commutated motors; indicate DDC control system is configured to vary air terminal fan speed as a function of the load; indicate fan speed during periods of low heating, low cooling, or ventilation only is 5 66% of peak design air flow or provide supporting documentation for applied exception 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 7 of 7 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 ov Project Title: Fill this Zine out on MECH-SUM (Date 1/1/2015 the following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents - Location in Documents Building Department Notes +� f C403.7, Item 11 Application of single duct un fan-poweredd terminal Indicate VAV terminal types on plans; verify fan -powered terminal units only serve perimeter zones with envelope loads; verify all other zones are served by single duct terminal units C403.7, Item 12 Fan -powered terminal unit primary air reset Indicate DDC controls are configured to automatically reset the primary supply air cfm setpoint of all fan -powered terminal units to the minimum required to maintain ventilation during occupied heating or deadband, based upon the VAV air handling unit OSA ventilation fraction C403.7, Item 13 High occupancy space controls For spaces > 150 sf with occupant density 2 25 people / 1000 sf, indicate space is served by a dedicated terminal unit with DCV control that resets terminal unit ventilation setpoint; also indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by 2 5°F C403.7, Item 14 Dedicated HVAC systems For server, electronic equipment, telecom or similar spaces with cooling loads > 5 W/sf, Indicate spaces are served by independent HVAC systems that are separate from HPVAV systems serving rest of building; indicate dedicated HVAC systems have air economizer controls or energy recovery per C403.3 Exception 9 Indicate whether systems are served by a high efficiency heating water plant, or a high efficiency chilled water plant C403.7, Central plant efficiency If complying via high efficiency heating water plant: Indicate all VAV terminals have hydronic heating coils served by heating water system with either gas-fired boiler(s) with thermal efficiency 2 90%, air -to -water heat pumps, or heat recovery chillers Item 15 If complying via high efficiency chilled water plant: Indicate all VAV air handlers have cooling coils served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25% per Table C403.2.3(7) (note water-cooled IPLV is max, all others are min); indicate smallest chiller or compressor in plant is 5 20% of total plant capacity, or provide thermal storage sized for 5 20% of total plant capacity C403.7, Item 16 Faun detection and diagnostics Indicate DDC system includes a fault detection and diagnostics (FDD) system configured to monitor operation and provide fault reporting of required parameters for all VAV air handlers and VAV air terminal units in the HPVAV system HVA Equipment Energy Use Metering C409.3.1 HVAC equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, verify energy use metering of all equipment used to provide space heating and cooling, dehumidification and ventilation will be provided per C409; indicate equipment eligible for exception Documentation and System Specific Requirement To Support Commissioning Scope of mechanical Indicate that all mechanical systems, equipment, and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; C408.2 systems commissioning For buildings with z 240,000 Btu/h total output cooling capacity or a 300,000 Btu/h total output heating capacity, indicate that all mechanical systems regardless of individual capacity are required to be commissioned; or provide building heating / cooling capacity calculation demonstrating eligibility for exception Indicate in plans and specifications that Cx per C408 is required for all applicable mechanical systems; C403.2.10 C408.1.1 C408.1.2 C408.1.4.2 Commissioning requirements in construction documents Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); C103.6 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical Inspection. C408.2.2 Air system and hydronic system balancing Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances defined in the specifications; indicate systems shall be balanced in a manner to first minimize throttling losses, then adjusted to meet design flow conditions C408.2.2.1 Air system balancing devices Indicate devices that provide the capability to balance all supply air outlets, zone terminals and air handling equipment requiring system balancing C408.2.2.2 Hydronlc system balancing devices Indicate devices that provide the capability to isolate, balance and measure flow across all hydronic equipment requiring system balancing including heating and cooling coils and pumps C408.2.3 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems Project Close Out Documentation `If�i, `rV� I C103.6 Documentation and project close out submittal requirements Indicate in plans that project close out documentation and training of building operations personnel is required for all mechanical components, equipment and systems govemed by this code; Indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Ec`onomizer Exceptions MECH-ECONO 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Fill this line out on MECH-SUM Date 1/1/2015 All cooling systems shall be configured to provide air economizer operation, regardless of system capacity, for new construction and mechanical system alterations. Various exceptions to this requirement are available. Identify all systems that an economizer exception will be applied to and additional information as noted below. For Building Dept. Use Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS Exp 1 Cooling equipment serving spaces that are provided with a dedicated outdoor air system (DOAS) per C403.6. Spaces served shall have year- round design cooling loads from lights and equipment less than 5 watts per square foot. System ID Lighting + Equipment Loads (W/sf) Exp 2 Single zone unitary or package systems with dehumidification that affect other systems such that air economizer would increase energy consumption. System ID Exp 3 High efficiency single zone unitary or packaged systems. Equipment cooling efficiency shall be better than the WSEC required minimum efficiency by at least 64% in Climate Zone 4C and 59% in Climate Zone 5B per Table C403.3. System ID Exp 4 Equipment that provides hydronic chilled water for chilled beams and chilled ceiling systems that is served by a water economizer system per C403.3.4 in lieu of air economizer. System ID Exp 5 Water -source heat pumps with heat recovery. Heat pump efficiency shall be 15% better than WSEC required minimum efficiency. Provide at minimum 60% air economizer. Energy recovery to preheat OSA shall have at least 50% effectiveness. Additional system requirements apply. System ID Exp 6 Cooling equipment serving Group R occupancies. Per unit limit is less than 20,000 Btu/h cooling capacity for equipment installed outdoors or in a mech room adjacent to the outdoors. For cooling equipment installed in other locations the unit limit is less than 54,000 Btu/h. Efficiency shall be 15% better than WSEC required minimum efficiency. System ID Equipment Location Cooling Capacity (Btu/h) Exp 7 Variable refrigerant flow (VRF) systems with energy recovery. Outdoor unit shall be a reverse -cycle heat pump with variable speed compressor(s) and condenser fan(s). Outdoor unit cooling capacity shall be not less than 65,000 Btu/h. Energy recovery to preheat outdoor air shall have at least 50% rated effectiveness. System shall be capable of providing simultaneous heating and cooling by tranferring recovered energy from zone(s) in cooling mode to other zone(s) that are in heating mode. Outdoor Unit System ID Cooling Capacity (Btu/h) Exp 8 Cooling equipment serving Controlled Plant Growth Environments. Equipment cooling efficiency shall be better than WSEC required minimum efficiency by at least 20%. Not eligible: unitary and applied heat pumps. System ID SEER, EER, & IEER Exp 9 Cooling equipment with energy recovery. Spaces served shall have year-round design cooling loads from lights and equipment greater than 5 watts per square foot. Energy recovery system shall utilize recovered energy for on-site space heating or preheating of service hot water. Provide calculations to the code official that demonstrate the amount of recovered energy used for on-site heating purposes is equivalent to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID Lighting + Equipment Loads (W/sf) 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Economizer Exceptions, cont. MECH-ECONO 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Date 1/1/2015 Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS, CONTINUED Exp 10 Cooling equipment for dedicated server, electronic equipment or telecom switch rooms. Per building limit for this exception is 240,000 Btu/h cooling capacity or 10% of required building air economizer capacity, whichever is greater. Part load control required over 85,000 Btu/h. Additional requirements apply. Option a - Cooling equipment efficiency shall be 15% better than the WSEC required minimum efficiency.. Option b - Waterside economizer required. Cooling equipment efficiency shall be 5% better than the WSEC required minimum efficiency. Option c - Waterside economizer required. All cooling equipment is subject to ASHARE Standard 127. System ID Compliance Option Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 240 kBtu/h): Alternate Exp 10 Capacity Limit: ECONOMIZER EXCEPTIONS - MECHANICAL SYSTEM ALTERATIONS OR REPLACEMENT C503.4 Pre -approved design alternative to full compliance with air economizer Exp 1 requirement. An altemative for mechanical system alterations where existing building constraints make full compliance with air economizer requirement impractical. Provide calculations to the code official that demonstrate the proposed altemate design strategy provides similar energy savings to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID Alt. Strategy ECONOMIZER EXCEPTIONS - SIMPLE SYSTEMS C503.4 Qualifying small equipment. Per unit limit less than 33,000 Btu/h. Per Exp 2 building limit for this exception is 72,000 Btu/h cooling capacity or 5% of required building air economizer capacity, whichever is greater. Cooling equipment efficiency shall be 15% better than WSEC required minimum efficiency. Not eligible: non -unitary equipment, unitary equipment installed outdoors or in mech room adjacent to outdoors, equipment installed during new construction, shell -and -core construction, or initial tenant improvement. System ID Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 72,000 Btu/h): Alternate C503.4 Exp 2 Capacity Limit: C503.4 Equipment that provides hydronic chilled water for chilled water terminal Exp 3 units. Equipment part load cooling efficiency (IPLV) shall be better than WSEC required minimum efficiency by at least 25%. Per building limit for this exception is 480,000 Btu/h cooling capacity or 20% of required building air economizer capacity, whichever is greater. Chilled water terminal units serving Group R occupancies are not included in the building capacity total. System ID Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 480,000 Btu/h): Alternate C503.4 Exp 3 Capacity Limit: Table Compliance Options for alteration or replacement of existing C503.4 mechanical cooling equipment per Table C503.4. Refer to table and all applicable table footnotes for full requirements. Applies to the following retrofit conditions: Option a - Any new or replacement equipment Option b - Replacement equipment of same type with same or smaller cooling output capacity. Option c - Replacement equipment of same type with large cooling output capacity. Option d - New equipment added to existing system or replacement equipment that is different than existing being replaced. System ID Equipment Type Compliance Path • 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Fan System Power Allowance* MECH-FANSYS-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings includin R2 & R3 over 3 stories and II R1 R ' ed J g • Project Title: Fill this line out on MECH-SUM a eves anuary 201 Date 1/1/2015 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces -they serve. System or Primary Supply Fan ID Speed Control (Note 1) Description (Note 2) System Total Nameplate HP (Note 3) Fan Power Calculation Required (Note 4) VTO 1 N o Q4040itt2A5 t. 2.7.- N`04- . Note 1 - Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403.2.11.1 Exception Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list all fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. all supply, retum/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series terminals. VAV parallel fan powered terminals and economizer relief fans do not need to be included if the fans do not operate at conditions. Note 3 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No) 1. Include fan -powered peak (Yes), MECH-FANSYS Forms , A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5'hp. Select (Add Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E32 of the added form. 2.015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Fan System Power Allowance'). MECH-FANSYS 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and ali R1 Revised Janua 2017 Project Title: Fill this line out on MECH-SUM 9 ry Date 1/1/2015 A separate MECH-FANSYS form must be completed for every HVAC system that exceeds the 5 hp threshold. For Building Dept. Use Fan System ID S stem Supply Fan Y PP Y Speed Control�system , 4 3 1.1 Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV that qualifies for VAV budget per C403.2.11.1, Exception 1 Compliance Option Compliance is based upon either the fan motor nameplate horse power (Option 1), the fan brake horsepower (Option 2), or C403.7 high efficieny VAV fan brake horsepower (10% less than Option 2). The bhp calculation provides adjustments for special equipment per Table C403.2.11.1(2). Fan S stem Supply Y PP Y CFM Total - In Fan Equipment Schedule below, provide maximum design supply airflow rate (CFM) of all supply fans serving the conditioned space in Fan Equipment Schedule below. Fan System CFM Total is the supply airflow of the central air handler at peak design conditions. Additional volumetric air flow provided at zone fan terminals, booster fans, or through induction is not included In the supply CFM total. However, the fan power of this equipment is included in the HP"and •BHP calculations. Fan System Supply CFM Total Is automatically calculated by the form. Fan Equipment Schedule Fan ID and Location Fan Type Quantity of Fan Type Total CFM (Note 1) Total Nameplate HP (Note 2) Total BHP (Note 3) Note 1 - Total CFM is the maximum CFM of the listed fan(s) when Total Proposed: operating at peak design operating conditions. Note 2 - Total namplate hp of the listed fan(s). Total Allowance: Note 3 - Total brake horsepower (bhp) of the listed fan(s) at peak design operating conditions. Not required if Nameplate HP compliance option chosen. Compliance Message: " Brake Horsepower Allowance Adjustments Device Type Description and Location CFM thorough this device (CFMD) Assigned Pressure' Drop, PD in w.c. (Note 6) Calculated Pressure Drop, PD in w.c. (Note 7) Adjustment, A in bhp (Note 8) • Note 4 - Bhp allowance for energy recovery devices and run around coil loops includes both air Total Adjustment (bhp): streams, so the CFMD is the sum of the suooly CFM and exhaust CFM if hath9 o throw t, the device. Note 5 - Energy recovery effectiveness is defined as change in the enthalpy of the outdoor air supply divided by the enthaply difference between the outdoor air and retum air at design conditions. Note 6 - Assigned pressure drop (PD) adjustment per Table C403.2.11.1(2). Note 7 - Pressure drop (PD) adjustment shall be calculated per the applicable method defined in Table C403.2.11.1(2) based on specific system conditions. Note 8 - A = PD • CFMD/4131 where A is the allowed system brake horse power adjustment, PD is pressure drop allowance, and CFMD is the cfm through the device. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 General Instructions: A. Include all fans directly associated with the delivery and removal of conditioned air to the zones served by the system. Enter CFM and brake horsepower (bhp) of each fan at peak design conditions and the nameplate horsepower (hp). Include supply, return and relief fans, exhaust and exhaust hood fans (>1 hp), booster fans and fans included as part of make-up air units, dedicated outside air systems (DOAS), energy recovery ventilators (ERV), and series fan -powered terminal equipment. B. VAV parallel fan powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. C. Fans not directly associated with the delivery and removal of conditioned air, such as condenser fans, do not need to be included in the fan power total. D. Fan power calculations are not required for non -central air HVAC systems such as 4 -pipe fan coils and variable refrigerant flow (VRF) systems unless individual fan systems are greater than 5hp. E. In the Brake Horsepower Allowance Adjustments table, if a Device Type is selected that has an Assigned Pressure Drop, this value will autofill into the Assigned Pressure Drop cell and the Calculated Pressure Drop cell will be write -protected. If the Device Type requires a Calculated Pressure Drop, then enter this value into the Calculated Pressure Drop cell and the Assigned Pressure Drop cell with be write protected. F. Refer to FAQ section of MECH-FANSYS-DOC for additional instructions. Fan lower Allowance Adjustment Factors 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 MECH-FANSYS-DOC 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Revised January 2017 TABLE C403.2.11.1(2) FAN POWER LIMITATION PRESSURE D Device Adjustment Credits Fully ducted return and/or exhaust air systems 0.5 inch w.c. (2.15 inches w.c. for laboratory and vivarium systems) Return and/or exhaust air flow control devices 0.5 inch w.c. Exhaust filters, scrubbers, or other exhaust treatment The pressure drop of device calculated at fan system design condition Particulate filtration credit: MERV 9 - 12 0.5 inch w.c. Particulate filtration credit: MERV 13 - 15 0.9 inch w.c. Particulate filtration credit: MERV 16 and greater and electronically enhanced filters Pressure drop calculated at 2x clean filter pressure drop at fan system design condition Carbon and other gas -phase air cleaners Clean filter pressure drop at fan system design condition Biosafety cabinet Pressure drop of device at fan system design condition Energy recovery device, other than coil runaround loop (2.2 x energy recovery effectiveness) — 0.5 inch w.c. for each airstream Coil runaround loop 0.6 inch w.c. for each airstream Evaporative humidifier/cooler in series with another cooling coil Pressure drop of device at fan system design conditions Sound attenuation section (fans serving spaces with design background noise goals below NC35) 0.15 inch w.c. Exhaust system serving fume hoods 0.35 inch w.c. Laboratory and vivarium exhaust systems in high-rise buildings 0.25 inch w.c./100 feet of vertical duct exceeding 75 feet Deductions Systems without central cooling device -0.5 inch w.c. Systems without central heating device -0.3 inch w.c. Systems with central electric resistance heat -0.2 inch w.c. ...— W dL 1 l:u1LLL1II. For SI: 1 inch w.c..= 249 Pa, 1 inch .= 25.4 mm. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Design Load Calculation Summary MECH-LOAD-CALC 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all RRevised January 2017 Project Title: Fill this line out on MECH-SUM Date 1/1/2015 The following information shall be included in the Toad calculation program summary submitted with the permit documents. If a load calculation summary is not available, provide the required information below. For Building Dept. Use Equip. ID Area(s) Served Heating Design Cooling Design Load in Btu/h (Note Load in Btu/h (Note 1) 1) Calculation Method (Note 2) 4 Notes Note 1 - Design load shall account for the building envelope, lighting, ventilation and occupancy loads of the space(s) served by the mechanical system. Heating and cooling loads shall be adjusted to account for load reduction achieved by an energy recovery system, if applicable. Note 2 - Computer load calculation program, worksheet (identify source), or equivalent computation procedure in accordance with ASHRAE Standard 183. l�C Table GD -2 — General Data General Data TRANEe (5 - 6 Tons) Standard Efficiency YSC060A1 Cooling Performance Gross Cooling Capacity 63,100 SEER,EER2 9.90/— Nominal CFM / ARI Rated CFM 2,000/2,000 ARI Net Cooling Capacity 60,000 Integrated Part LoadValue' — System Power (KW) 6.86 Heating Performance Heating Models lav Medium High law Medium's Figh law Medium'a High Heating Input (Btu) 60,000 80,000 130,000 60,000 80,000 130,000 80,000 120,000 150,000 Heating Output (Btu) 47,000 63,000 103,000 48,000 64,000 104,000 64,800 97,200 121,500 AFUE%5 81 81 80 81 81 80 81 81 81 Steady State Efficiency (%) 81 81 80 81 81 80 81 81 ' 81 No. Bumers 2 2 3 2 2 3 2 3 3 No. Stages 1 1 1 1 1 1 1 1 2 Gas Supply Line Pressure Natural (minimum/maximum) 4.5/14.0 4.5/14.0 4.5/14.0 LP (minimum/maximum) 10.0/14.0 10.0/14.0 10.0/14.0 Gas Connection Pipe Size (in.) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 Comp/ YPe r 5Ton Convertible YSC060A3, A4, AW, AK 63,100 10.20/- 2,000/2,000 60,000 6.78 6Ton Convertible YSC072A3, A4, AW, AK 72,000 —/10.212 2,400/2,100 69,000 6.77 1/Scroll 1/Scroll 1/Scroll Outdoor Sound Rating (dB)8 84 84 88 Outdoor Coil -Type Lanced Lanced Lanced Tube Size (in.) OD 03125 0.3125 0.3125 Face Area (sq ft) 8.81 8.81 13.88 Rows/FPI 2/17 2/17 2/17 indoor Coil -Type Lanced Lanced Lanced Tube Size (in.) 0.3125 0.3125 0.3125 Face Area (sq ft) 5.00 5.00 9.89 Rows/FPI 3/16 3/16 2/16 Refrigerant Control Short Orifice Short Orifice Short Orifice Drain Connection No/Size (in.) 1/V4 NPT 1/3/4 NPT 1/3/4 NPT Outdoor Fan -Type Propeller Propeller Propeller No. Used/Diameter (in.) 1/22 1/22 1/26 DriveType/No. Speeds Direct/1 Direct/1 Direct/1 CFM 3,470 3,470 No. Motors/HP 1/0.33 1/0.3315 6,1004 1,075 Motor RPM 1075 11 70 1,075 Direct Drive indoor Fan -Type FC Centrifugal FC Centrifugal WA No. Used/Diameter (in.) 1/11 x 118 1/11 x 118 WA DriveType'No. Speeds Direct/2 Direct/2 No. Motors 1 N/A 1 N/A Motor HP (Standard/Oversized) 0.90/1.00 0.90/1.0016 N/A Motor RPM (Standard/Oversized) 985/1,0809 985/1,0809 WA Motor Frame Size (Standard/Oversized) 48/48 48/48 N/A REVIEWED FOR CODE COMPLIANCE APPROVED AN 3 0 2011 City of Tukwila BUILDING DIVISION FITPRC006-EN oioq RECEIVED CITY OF TUKWILA AUG 112017 PERMIT CENTER 17 General Data (5 - 6 Tons) Standard Efficiency Table GD -2 — Continued 5Ton Convertible YSC06OA1 rYSC06073- A4, AW, AK 'FC Centrifugal 1/11 x 11 BeltNariable Sheave 1 1.00/- 1,750/ — 48/- 6Ton Convertible YSc072A3, A4, AW, AK Belt Drive Indoor Fan -Type FC Centrifugal No. Used/Diameter (in.) — 1/12 x 12 DriveTypeMo. Speeds — Belt/Variable Sheave No. Motors _ 1 Motor HP (Standard/Oversized) — 1.00/2.00" Motor RPM (Standard/Oversized) — 1,750/1,750 Motor Frame Size (Standard/Oversized) — 56/56 Filters -Type Furnished 1' Throwaway Throwaway (No.) Size Recommended (2) 20 x 25 10 (2 20 x 10 Throwaway Refrigerant Charge (Lbs of R-2217 4.7 14) 16 x 25 x 2 49 71 Notes: 1. Cooling Performance is rated at 95 F ambient, B0 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat: ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to o20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz) units. 2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. 3. Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80° F ambient, B0° F entering dry bulb, and 67° F entering wet bulb at ARI rated cfm. 4. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. 5. AFUE is rated in accordance with DOE test procedures. 6. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For additional information refer to Table PD -90. 7. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 8. YSC060A1,3,4,W Oversized Motor and YSC060AK Standard Motor Fan Diameter is 12 x 11. 9. Motor RPM shown is low speed. High speed RPM is 1100/1135. 10. Filter size shown is for low and medium heat models. High heat model filter size recommended is 20 x 30 x 1. 11. Optional 2" pleated filters also available. 12. YSC072A when used in a horizontal application has an EER of 10.1 and System Power (kW) of 6.83. 13. Medium heat is not available for AK (380V/60 Hz) units. 14. Outdoor motor is 0.75 hp for AK (380V/60 Hz) units. 15. Outdoor motor is 0.40 hp for AK (380V/60 Hz) units. 16. Standard Motor is 1.00 hp for YSCO60AK (380V/60 Hz) units. 17. Standard Motor is 2.00 hp for the YSC072AK (380V/60 Hz) units. 18 RT-PRC006-EN Weights Table W-1 — Maximum Unit And Comer Weights (Lbs) And Center Of Gravity Dimensions (In.) Unit Maximum Weights (Lbs)2 ComerWeights (Lbs)' Center of Gravity (In.) Tons Model No. Shipping Net A B C D Length Width 3 YSC036A 572 480 151 124 96 109 32 19 `11-1CO36A 589 497 158 128 101 110 32 19 4 YSC048A 5.97 505 199 130 108 109 33 19 YHC048A 631 539 166 133 114 126 32 20 — A 614 4` 522 169 134 105 114 32 18 <_--'� YHC060A 666 ` 574 179 140 719 136 32 20 6 YSC072A 878 735 249 193 132 161 39 21 A 915 772 249 193 141 184 39 22 A 963 820 273 208 146 193 38 22 71/2 YSC092A 965 822 277 222 147 175 40 21 A 1066 923 306 243 165 210 39 22 81/2 YSC102A 1042 893 297 243 165 191 40 21 YHC102A 1100 957 310 252 175 220 40 22 10 YSC120A 1063 958 317 261 177 202 41 21 YHC120A 1203 1060 342 277 197 245 40 22 Notes: 1. Corner weights are given for information only. 2. Weights are approximate. 94 CENTER OF GRAVITY .•—..-- LENGTH CENTER OF GRAVITY WIDTH D CENTER OF GRAVITY Table W,2 — Factory -installed Options I!et Weights (Lbs)t-2 Accessory Economizer Net Weight 3-5Tons 6-10Torts 26ai 36 Barometric Relief 7' - 10 Powered Exhaust _ 80 Motorized Outside Air Damper 20 f 30 Manual Outside Air Damper 16 26 Roof Curb Oversized Motor 70 115 5 8 Belt Drive Motor 31 Smoke Detector, Return 7 7 Smoke Detector, Supply Coil Guards 5 5 12 20 Hinged Doors 10 12 Powered Convenience Outlet 38 38 Through the Base Electrical 8 13 Through the Base Gas 5 5 Unit Mounted Circuit Breaker _5.._ 5 Unit Mounted Disconnect e...... 5--F.,- 5 Novar Control 8 8 Dehumidification (Hot Gas Reheat) Coil 15 25 Notes: 1. Weights for options not listed are < 5 Ibs. 2.Net weight should be added to unit weight when ordering factory -installed accessories. RTPR0006•EN REVIEWED FOR CODE COMPLIANCE APPROVED AN 3 0 2011 City of Tukwila BUILDING. DIVISION CCarrier United Technologies SUBMITTAL Project Parkway Village Date Tuesday, July 18, 2017 Contractor Seattle Mechanical 0109 RECEIVED CITY OF TUKWILA AUG 112011 PERMIT CENTER 5t Unit Project: Parkway Village Prepared By: 07/18/2017 07:42AM Packaged Rooftop Builder 1.49 5t Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Page 2 of 14 Project: Parkway Village Prepared By: Unit Report For 5t Unit 07/18/2017 07:42AM Unit Parameters Unit Model. 50KCQA06A2A5-0A0A0 Unit Size. 06 (5 Tons) Volts -Phase -Hertz 208-3-60 Dimensions (ft. in.) & Weight (lb.)*** Unit Length. 6' 2.375" Unit Width 3' 10.75" Unit Height 3' 5.375" Heating Type. Heat Pump *•* Total Operating Weight 660 Ib Duct Cfg. Vertical Supply / Vertical Return Standard One -Stage Cooling Refrigeration Coil Lines and Filters Return Air Filter Type. Throwaway Return Air Filter Quantity• 4 Return Air Filter Size• 16 x 16 x 2 Unit Configuration Medium Static Option Belt Drive AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty. Information 5 -Year electric heaters (STD.) 1 -Year parts (STD.) 5 -Year Compressor (std.) No optional warranties were selected. *" Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50KCQA06A2A5-0A0A0 Rooftop Unit 1 Base Unit Medium Static Option Belt Drive None Accessories CRECOMZR067A01 Ultra LOW LEAK - Vertical EconoMi$er X with solid-state W7220 controller 1 CRHEATER104B00 7.9/9.6/10.5 kW 208/230/240-1/3-60 Volt Electric Heater 2 CRSINGLE039A00 Single Point Kit 1 Packaged Rooftop Builder 1.49 Page 3 of 14 Project: Parkway Village Prepared By: Certified Drawing for 5t Unit 07/18/2017 07:42AM 101(5: 1. 0360041083 nE 11 101X(5 0131990031 58 1 1 63( 13 6141(1111(5. 1. 0(611 OF 0630(0 3. *, 013(11104 Or 419 (109 4. —Ej • ALL 3109 DOA woo 3RD 49GM DRAWING REPRESENTS PRODUCT BUILT AFTER 01/01/2017 (STARTING WITH SERIAL NUMBER 0117...) SEE DETAIL "E" anger 1 4u a t ale�""ir a'iu n 041 i4nt.Marterrov nem 4098017109 SIMS 3 311. 1131 019 FIELD PORI 32PPL1 ROSE 2. 1703 DIA 308ER SUPPLY IIgIWT 314. 1511 513 DIME 3CRn RW 213. 0221 DIA FIELD 001102 (18133 1(0.0 311'-11 IPT COMEIn1E 5MA13 2 I/O • 1611 IIA 0131E5 SUPPLY 3110[8-001 1683-rR-0081 CRAM 18010 ZEUS 10331809 FOR USE 43510330431691. 11(1813 1111 300'8 1410 (OMIT SIR USE 513(3 1110.1 r 112• 151 113• 122.11 I 111• 143 116. 121.11 S 311• PRIER 1-11.128.3 f0(3T101S1i0R8061Y01• 0 03 o0 ED ME ME 11110 FIE MSE 04381 SEE DETAIL E 141(1 S • 11351 TOP -SAI 3 1 1113.41 LEFT Packaged Rooftop Builder 1.49 14 40630131181133 I 04041 U.S. ECCN:NS5 1 OF 3 0314 noecCDE3 50610 0I-06 SINGLE ZONEELECTRIC 300 6-24-2016 19 -IT -2014 I BEAT PUMP I /6X4000263 I A Page 4 of 14 Project: Parkway Village • Prepared By: Certified Drawing for 5t Unit 07/18/2017 07:42AM 80(13: 1. 8 318(/118/AK (8 117183 0188857045 le 1 1 887 I8 e1LL(I(1ES5. I. (e (8M8(8 Of 80037! 3. MO, (memo Or Aro row *.—E4 611 91CA 01181 11110 380 AILS 78)3 53!60.01 13 118 18111 11 ll6 11117 !01000.05 Al 318 111511 lib 13111 500(0.01 *1 Ile 11031) f1 10 Inn A]CCe W 91X01 1133 608E** BACN 2-31e Inns [151 119 ,111 I3TR g eu'I1lVIlA[k118886!b*eiv'lp 10A111nrt rrr���ea DRAWING REPRESENTS PRODUCT BUILT BEFORE 01/01/2017 SEE DETAIL "B" ' ECW01171t 8007 08(74411 `�--- 25 ale 8(111811116. (MDEISER. cot(• IMnWAO 3171081 [O• W[00311 7 ^ I .�1 I1 II1 [7)87) LEFT Packaged Rooftop Builder 1.49 E�e 1 I1 16128 Leu 11-111 I I 11541 I [363) ) — 4103 11311 �. 32 Ill —.. 16131 6[E MAIL 8 MI 5 1\ 9 EALT.— 08Aj 0838111886 10 863E00 TOP 6.1)1 111)1 x 1101) 1 4.11 1 -Ile (0112 1161111 I 1 K1le 11-]11 11111 141] AI* [1131 818 3418 7831 7'118 111311871) 0048(71(08 312ES A 1 Ile• 1351 016 3(110 POIFI 1U1PLP MOLE 0' 1301 OIA 511[8 8U7911 1148001 1 III. 1311 016 00(18 463E63 9100 Ile• (221 DIA FIELD CO4T0L 511(83 80.E 311•-11 MPT CO80E8*A1E 08AI8 0 70 • 111] DIA 908(8 !WILY 5110C11-001 11(67 1318-I11E7115[ C36*1 80113 808168(0 708 (5E 08111/1/02201 (58(3KR 1(03 837 61733 POLE WIWI • 1)' 1132 7)6' 1]].21 4 110• 243 716' 122.01 ! • 371• POWER 1 118' 788.86 706 •111(-111-883[88' 7![108! 091108, 71711803 103 0411 6,! KC 3300(3(0 • !ELECT 311X1! 31*• 08 7)7• 738 88878, 0(1780183 18 8311 337E 311 * 888rty 011! *I8 ; :17.„„ RIGHT ITC cu11(im 1134 s8ttr 0*14 80"3"."80"3"."U.S. ECC*:RSR - I 2 OF 5 5-21-8015 1 3-17-1011 I 508[0 01-06 NFA( PU PpIE ELECTRIC I 16X000018) I RAv Page 5 of 14 Project: Parkway \tiIlage Prepared By: Certified Drawing for 5t Unit 07/18/2017 07:42AM PITT 410. 00(401 LA3, UNIT 56. COe0ER 001671 Lee. lel Re. C00*13 171001 053. lei k6. C01000 1111611T 155, ICI 0*. coni(* 0E1031 Lee. 10) k0. C,6, I I WEIGHT t )0100)01 405 714 lee 31 110 51 Ile 33 130 33 35 ere 103113 73 ere 6913 le )re (7111 503(0103 $10 753 161 53 577 69 110 59 147 ee 35 172 11071 11 118 15501 20 171 15111 503(0101 110 714 160 13 1)1 el 111 61 132 et 35 era Ilett 40 4,2 (5111 20 are 15711 Id1A 0430 (*1T 01(697 (5 1(1140? 111073(6 9 1 400 *(104011 *56075300. p 0120 1511033 * 7 u6E1509(03. 0060 10 71E *500061 0*13 611700 CORNER A CORNER 0 TOP OP Ikill Moo I 1 I I . 00E - Packaged Rooftop Builder 1.49 FRONT CORNER 8 CORNER C ITR 011*13PE0*Tim U.S. ECCR:RSR .rmums 111,/ mm memo ge no mom colun "TOMpirja=“' 11rr trte_.. �.. BACK_.--_ WITH ECONOMIZER RI? 114 111111 BACK KIT OUT ECONOMIZER LEFT 0ni13O0170*.AL DOOR 1) 0700 4000 l � 51• - FRONT l' 001[6: 1. F0* ALL 7111190 CLI43*06ES LOCAL 00063 OR 100150161(005 RAI PREVAIL. 11.16112 MONT LOFT !MS MOOD WSW Ta SNER DA E 300(36(OC3 3 OF 5 6-24-2016 9-17-2014 IMINIZ CLENVIICE CCIOICIIRE WIRER 48 (121955] 48 (1319035] 48 (1219031 36 (9141ni) 36 (914031 12 11829031 80IRCE VTR 9OWOUCIM MRI881 36 (614031 42 (1061031 42 (1067031 36 (914031 36 (914031 72 (182903] 506C0 04-06 6111GLE 009E ELECTRIC RFC PUMP Page 6 of 14 Project: Parkway Village Prepared By: Certified Drawing for 5t Unit 07/18/2017 07:42AM ••••••••••MSIIMI E14 X11.fga.N RO [MP [11![1,5154[ Ei �p Mt�P�� �i;mt a i�4ii:c7'"' ,111516F TIE SASESjl1F 1 SKIM . .ACCESS 1 IPOOOI COIL ACCESS PAPA 41 t MIK TAE 0 0 / INSIDE BASERAIL DIMENSIONS BOTTOM 11 CIO, w6a IILTFI ACCF# MNFI ITOOliI5S1 . .ACCESS ` COIL COIL IPOOOI COIL ACCESS PAPA bi fr r_C-IT-rloa4 Packaged Rooftop Builder 1.49 BACK LEFT STC CLASSItICATIOP I SREET U.S. ECCS:NSR 4 OF S �[E OMR C 0-IS/0i5/11CA] r-- TTI COR! 1116111 O111 AAPINC10FI HALO 04-06 SINGLE ZONE ELECTRIC I-24-2016 I 9-11-1014 NEAT PUMP ISI 485E000253A Page 7of14 Project: Parkway Village Prepared By: Certified Drawing for 5t Unit 07/18/2017 07:42AM 0100 -TOE -OA E OW 11•50 11F50 lass REWIRED Fa USE CPoTW12001231 12205[0 •IRs Afro 100E C 000T SIRE Rs SIDES 1141.1 • 111' 1101, 1I6' 121.21 2 t/1' 142 T/5. 122.21 I • S/A' NKR 1 115' 020.10 EOR 'mo-TBE-0/SE Ar r1[Tas MT101, FIT1I1115 120 ORIS S,I A5E 52000202 ' • SELECT EITIE5 311. OR 1/2' FOR 50155, OEPER0250 OR 520E 5001 II OCTAD 8 riamut I ------------------------------'-----I 4125 Ub 4 MIRA Il 1.141 ot11.."b, �ti,RAA• [f 31111 nRN dtlin P,0 m,mf"."" 1d,b�b 1Cbk Mmbll aMe�iil m a991br 4� THEM DOLES NEWIRED FW 435E CI112MR041A21 133042(0 111E 200'2 5012 COMMIT SIM 051 SIZES 1144.1 1IV 1155 Ill' (12.20 1 I53' lir Ile 222.21 343• 00105 1-14.126.41 F0A 'T11I-TIE-SASF113' r [TOR, 0TI01, 111114,65 105 ONLY 1, t AME 51On0E0 • 1034412 I11•tn1p mile II502310 I 1 ! I 21 25 .., 3051 gun E Ma 51[22 21 25-311 25531 THIS VIEW REPRESENTS PRODUCT BUILT PRIOR TO 1/1/17 THIS VIEW REPRESENTS PRODUCT BUILT AFTER 1/1/17 Packaged Rooftop Builder 1.49 ITC cLAs0IIICAT1OA U.S. (CMOS sun 50F 5 - GAT2 0-24-2016 5n40E(1, 05-11-2011 502(0 04-06 SINGLE ZONE ELECTRIC HEAT PUB, 18X(000283 etv A Page 8of14 Project: Parkway Village. 07/18/2017 Prepared By: 07:42AM Certified Drawing for 5t Unit Packaged Rooftop Builder 1.49 Page 9 of 14 Service aearance caro, LOCATION DIMENSION CONDITION 4881 (1219 mer) • IMM disconnect Is mourned on peel A 18.4 (457 mm) • Mp disconnect. convenience outlet option • Recommended servkedearame 124n (SOS . ) • Mei/morn durance 424n (1667 mm) •arbce behind seodeerb grounded (e.g., metal, mammy we) 8 3681(914 mon) •5urbce blend ser9cer6 elect 1l 0y non-conductive (e.g.,wood. fiberglass) Special *Check tor sources at the products within la ft. or unit freshen Into* Ifo C 868n (91e mm) • Side condensate drain Is used 18.1n (457 mm) • Mhemwn deem= 4888(1219818) • No flue dlsdiarge =more Installed. surtece8 combustible materiel 42811/6788) • Surface behind seeker 4gmurded e.g..metal.maswoywall, another unit) 0 3681 4181) • 4atece behind senate.. 4 ehctrkagy nan-cmrdolle (e.g.. wood. fiberglass) Specie] •Checker adgoemudo or building freshetalahes within SO Ot's . of this min gine outlet MOTE: Shift rot designed to have overhead obstruction. Co0sal Application Engineering for guldecean any appgcaton planning overheadobstructko or vertical deermes. omni 43 Packaged Rooftop Builder 1.49 Page 9 of 14 Project: Parkway Village Prepared By: Performance Summary For 5t Unit 07/18/2017 07:42AM Part Number:5OKCQAO6A2A5-0A0A0 ARI SEER. 14.30 Base Unit Dimensions Unit Length. 74.4 in Unit Width _._ 46.8 in Unit Height 41.4 in Operating Weight Base Unit Weight 610 Ib Medium Static Option Belt Drive. 10 Ib Accessories 7.9/9.6/10.5 kW 208/230/240-1/3-60 Volt Electric Heater 30 Ib Single Point Kit 10 Ib Total Operating Weight 660 Ib Unit Unit Voltage -Phase -Hertz. 208-3-60 Air Discharge. Vertical Fan Drive Type- Belt Actual Airflow. 2000 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU/Ib Evaporator Leaving Air DB- 60.0 F Evaporator Leaving Air WB• 58.1 F Evaporator Leaving Air Enthalpy 25.12 BTU/Ib Gross Cooling Capacity 56.83 MBH Gross Sensible Capacity- 43.20 MBH Compressor Power Input 4.79 kW Coil Bypass Factor 0.156 Heating : Performance Outdoor Ambient Temperature. 47.0 F Entering Air Indoor Coil DB. 70.0 F Leaving Air Indoor. Coil DB• 95.9 F Total Heating Capacity. 55.90 MBH Integrated Heating Capacity 55.90 MBH Heating Power Input 4.07 kW HSPF. 8.2 Electric Heating Capacity 15.80 kW Unit Leaving Air Temp. 120.8 F Supply Fan External Static Pressure. 10.50 in wg Options / Accessories Static Pressure Electric Heaters- :0.17 in wg Total Application Static (ESP + Unit Opts/Acc.) 0.67 in wg Fan RPM. 1182 Fan Power 1.22 BHP NOTE. Selected IFM RPM Range: 1066 -1380 Electrical Data Voltage Range. 187.253 Compressor #1 RLA• 15.9 Packaged Rooftop Builder 1.49 Page 10 of 14 Project: Parkway Village Prepared By: Performance Summary For 5t Unit 07/18/2017 07:42AM Compressor #1 LRA. 110 Actual Electric Heater kW 15.8 Electric Heater FLA. 43.8 Outdoor Fan Motor Qty• 1 Outdoor Fan FLA (ea). . 1.4 Indoor Fan Motor Type MED Indoor Fan Motor FLA. 8.4 Power Supply MCA. 85 Power Supply MOCP (Fuse or HACR). 90 Disconnect Size FLA. 80 273 Electrical Convenience Outlet None Electric Heater Number of Stages' 2 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Disconnect Size LRA. Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 88.5 88.0 57.7 125 Hz 81.7 78.4 66.6 250 Hz 74.2 66.4 68.7 500 Hz 71.7 64.4 72.9 1000 Hz 70.9 66.0 74.5 2000 Hz 65.8 60.6 71.1 4000 Hz 67.5 56.7 67.6 8000 Hz 64.1 49.8 62.6 A -Weighted 76.3 70.5 79.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 57.7 66.6 68.7 72.9 74.5 71.1 67.6 62.6 79.1 Lw Packaged Rooftop Builder 1.49 Page 11 of 14 Project: Parkway Village Prepared By: Performance Summary For 5t Unit 07/18/2017 07:42AM B 31.5 50.5 60.1 69.7 74.5 72.3 68.6 61.5 78.1 LwA C 25.3 34.2 36.3 40.5 42.1 38.7 35.2 30.2 D -0.9 18.1 27.7 37.3 42.1 39.9 36.2 29.1 Legend A Sound Power Levels at Units Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA 46.7 Lp 45.7 LpA Calculation methods used in this program are pattemed after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve 18 -150C.RPM 71 17Q73i.. -11M 16 3.00BFF 1.504P 1,OOBFP 13 C6 09 12 15 Airflow(CFM-1 usands) RPM= 1182 BHP= 122 MaximumRPM=2100 MaxnmunBHP=2.90 Note: Pleasecontactapplicxdonengineeringforselectionsoutsidetheshadedregion. SC-SystemCurve RP-RatedPoint 21 24 27 Packaged Rooftop Builder 1.49 Page 12 of 14 Project: Parkway Village Prepared By: Unit Feature Sheet for 5t Unit 07/18/2017 07:42AM WeatherMakef - 50KCQ PACKAGED ROOFTOP NEAT PUMP UNITS -14 SEER WEATHERMAKER SERIES WeatherMaker 501=1 (14 SEER) units are single -packaged heat pump units that are prewired and charged with Puron (R -410x) refrigerant The units are factory tested and rated in accordance with AHRI Standard 2101240. Wert herMakerunits are designed in accordance with UL Standard 1995, and listed by the Underwriters' Laboratories. Puron C[RkiFED. Ulf a the MN artaea moteAnvitee nSo Miran Far yemhoeisn elorttd••rMrrrax4• mama WM •rni'+*arvs, Cerdfled to .ISO 9001 4,5TONS PERFORMANCE FEATURES • .PURON (R -410A) HFC refrigerant • Meets and exceedsASHRAE90.1eneegyetfa ancylevets • SEERsupto 14.4.EERsupto12.2..ISSPi^s up to 8.0 • Single stage wan capacity control • Exclusive noncorrosive composite condensate pan in accordance Pith ASIatAE 62 Standard. sloping design: side orcenterdrain • Coppertube aluminum fn cols with optional corrosion resistant coil • Pre -painted exteriorpanelsand p +erooatedite1iorpanelstestedto 500 hours salt spray protection • AcutroFTM refrigerant metering system • Cooling operating range upto 115F (40C) and down to 25 F (-4C) • Sodxtatecontrol board and easy access terminal board • Refit grant filter drier and accumulatoroneach refterantotouit • Fully insulated cabinet • Automatic used with a utotfnengeoverthemrostat • ;Rated in accordance wth AHRI Standards 240 • Loss of charge. freeze protection. and hih yresare watches • Dependable Time fTerrparature defrost board and logic • Listed twit. and UL. Canada MAINTENANCE FEATURES: • Accerapsr:akath easy grip handles • lnnovatim, easy starting. no strip screw features en unt access pants. • Tav-inch disposable return skitters • Tool -less fitter • ,Obeid Drive —ECM indoormotor is standard with optional b&t drive systems • Terminal board far:Mating simple safety6sarit trovbleshoofsng and. simplified controtboxarrangement INSTALLATION FEATURES: • Thnr-0he-bottompowerertryospablitystandard • Single point ekataiccennectcns • Pull perimeter hese nalwihbullar rigging adapters and fork truck slots • 'Meld convertible from vertical to horizontatairrbw STANDARD WARRANTY: • 8-yearelectric heaters • 5-yearconpresaor • 1-yearparls Many aptionaiwanantiesatso available OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • Premierlink and RTU Open Muni Protocol DDC Controls • Supptyand Return air smoke detectors • Non-fused disconnect watch, and convenience outletoptions • High staticn>otoroptons • Ow sensor • Corrosion resistant col options forevaporetorand condenser • field accessory etectwie heat and single point Ma (field -instated only) • bunged access panels • Integrated ewnor izersystem. Standard and L ltra Low Leak versions Fora complete flat of options and accessories referto the Product Data Catalog forthis unit. Packaged Rooftop Builder 1.49 Page 13 of 14 Spec Sheet for 5t Unit Project: Parkway Village Prepared By: 07/18/2017 07:42AM Packaged Rooftop Builder 1.49 Page 14 of 14 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 30 2011 City of Tukwila BUILDING DIVISION L STRUCTURAL CALCULATIONS Redwing RTU 17135 Southcenter Parkway Tukwila, Washington AUGUST 3, 2017 4.., SJ ;44 PREPARED FOR: Seattle Mechanical 899 West Main Street Auburn, Washington 98001 PREPARED BY: Moore Engineering Group 21902 96th Avenue SE 7 Snohomish, Washington RECEIVED CITY OF TUKWILA AUG 1 1 2017 PERMIT CENTER Moore EYVir'.4rj1LIR 1 Engineering Group Mt1oW1 GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTJS AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT 920 POUNDS EARTHQ''UAKE .... SDS = 0.968 SITE CLASS C WIND l 110 MPH, EXPOSURE B 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MEC ANICAL DRAWINGS FOR:BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VE FY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY EN SNEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITION§ '.PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON §ITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED t ONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER :PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACT R SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, CHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR TI -TE COMPLETION OF THE WORK. 7. SHEET M.ETIA.L SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". CONNECT THE UNIT TO THE METAL CURB WITH A :MINIMUM OF (3) #12 SHEET METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER O THE UNIT AND THE THIRD SCREW AT APPROXIMATELY THE MIDDLE OF THE UNIT OWN EACH SIDE. • Moore Engineering Group PROJECT: b\:ts Z V ENGR: /{,V DATE: SA/1'7 SCALE: l/ 2/9 SHEET PROTECT DESCRIPTION: The project consists of the replacement of an existing rooftop mechanical unit. LOADS: LIVE DEAD DEAD + L WIND SEISMIC E Roofing and re -roof 1/2' plywood sheathing 2x6 @ 24" on -center 4x14 @ 8' on -center Insulation MEP Ceiling & Lights Total Dead 110 mph, Exposure B Latitude Longitude Site Class SDS= EQUIPMENT Existing RTU -1 Unit 570 Existing C rb 110 Curb Ada ter 150 Total 830 pounds Dimensio 4.0 1.5 1.1 1.6 1.0 2.0 2.0 13.2 25 PSF 382 PSF 47.451 -122.263 C WA DNR 0.968 New RTU -1 660 110 150 920 pounds 74"x47"x73" high Moore Engineering Group PROJECT: REDWING RTU ENGR: KWM DATE: 8/3/ 17 SCALE: SHEET 7/29/2017 Design Maps Summary Report Design aps Summary Report User -Specified Input Report Title Redwing RTU Sat 3uly 29, 2017 13:55:57 UTC Building Code Reference Document 2012/2015 international Building Code (which utilizes USGS hazard data available in 2008) Site Coo dinates 47.451°N, 122.263°W Site Soil Class fication Site Class C - "Very Dense Soil and Soft Rock" Risk ategory I/1I/1I1 1i F1_0114'IICr own. ,,fir I ` `�� ;� RENTON � INN ii +� , I PA4t' . t1 ri�en ; 't=‘. Ilenton 'SEATTLE '` r1 ' 11 COMA PiTt : r AtF?POR ; 4,4';,;''' ••; Maple Valley Des . oin �) 'fir if L o Iah USGS-Provided Output Ss = 1.452 g S1 = 0.541 g s= 1.452g = 0.703 g "`zent •r ovingtori • Sos = 0.968 g Sol = 0.469 g •H o� Cea For information on how the SS ani. S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEIIRP" building code reference document. MCEER Response S ectrum MGI ago asp *xm 0.73 CIL" MI 21.51 : Pennon. >{ (see) 114 • a; :Aa Design Response Spectrucn +0 SI 7J a a1° xl 1:11 an; L. 4(4 11. 173 +_ PeKY1.T (Tae) •a I+fO _.1, Although this information is a produc@ of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therei`t. This tool is not a substitute for technical subject -matter knowledge. https://earthquake.usgs.gov/cn1/designmaps/us/summary.php?template=minimal&latitude=47.451 &longitude-122.263&siteclass=2&riskcategory=0&e,.. 1/1 Weights Mfg Wi -- Mixmlan Unit Am Coiner (Lis)And Center Ofavvity Dimensions (1nJ MatdrrlumWeghtsMOO CornerlWight!IWO 1431 A B C Unit Torts Mode No. 3 VBA .—r Yric0604 4 8 YHCW7A MEGA 71 Y90092A YHC032A YSC107A 814 YHC102A 10 Y5C120A YHC1204 Y5C072A Center of Gravity (kr.) 1-01/011 Wan 572 M81 151 124 96 109 32 19 5113 487 168 128 .101 110 32 19 1 MU 51b 159 135 108 109 33 19 831 539 1155 133 114 12 3 20 614 ✓ 572 189 134 105 114 32 18 886 574 179 140 119 135 32 20 878 746 249 193 132 151 21 �16 772 249 198 141 164 39 22 963 825 273 ZS 146 193 38 22 966 8221 277 272 147 175 40 21 1066 923 306 243 109 210 39 22 1042 869 237 273 166 191 ,40 21 1100 957 310 252 175 220 40 22 1063 95 317 281 177 202 41 21 1203 1060 342 277 157 245 40 22 NM03: 1. Comer weights era own for Mormetbn 2. Weighte eta approximate.. 94 Y• 4-- 7 1e W2 — Fectorpletstalied Options Net Miens 11h)i" Accessory Economizer NetWaight 3-5Tons 6.10Tons 7- 28 t 38 Barometric Re9ef 7 4 10 Azweted Exhaust 80 Motormed Oatede Air Damper 20 r 30 Manual Outside Air Damper 16 26 Roof Curb 70 115 Oversized Motor 5 8 Bah Drive Motor 31 Smoke Detector, Raum 7 7 Smoke D Supply 5 5 Cog Guards 12 20 Hinged Doors_ 10 12 RIWINIXI Convenience Outlet 38 38 'Through the Rase Samba 8 13 Through the Bose Gas Unit Mounted Qr iltBreaker Unit Mounted Disoonnat 5 5 5 5 5 6 Hover Control 8 8 Oehumldiiicatton Hot Gas Reheat) Cog 13 25 Notes: /Weights foro Dion not listed ere <5 tbs. 2Netwetghtshautd be edited to unit weidM when orderingteetoryinsteiled accessaries. RFPR0006 34 General Data (5 - 6 Ts Standard Efficiency DM, GD2 — Data Cooing Perforrroros' Grose Cooling Capacity SIMMER, Nominal CFM/ARI Famed CFNI ARI Nat CooTerm Cegchy integrated Part LoadVelue' System Power (KW) (feeds* Perbrn anee* Heating Media Heating Input (btu) ItoeNng Ou8ax (Btu) ARJlxiba Steady State Efficiency (%l No. Burners 0/0. Stages Gas Supply Line Pressure Natural (Wetmore/maximum) tP (minimnanhnmdmum) Gas Connection Pipe Size (ln.) Compressor Outdoor Sound Rating (dBP Outdoor Coll -Type Tube Star 6n) OD Face Area (as RI Rows/FPI Moor Call Type TUbe Sit (in.l Face Area (sq ft) RoweFR Refrigerant Control Drain Cormacijon No/Size 8n.) Outdoor Fan -Type N0. Lhsdiphmteter OriveTypeNtr, Speeds CFM Na MoloreHP MotarRPM 5Ton Convertible YSCO60A1 rCSC060A31A4, AW, AK 63,100 67.100 9.801— 10.20/- 2400/2,000 2.0002400 60,000 60.000 6.86 6.78 6Ton Convertible VSC072A3,A4,AW, AK 72.000 —f10.2" 2.400100 69.000 Direct MI* Indoor Fan Type No. UsodDlemeter On.) thlveTypeNo.Speeds No, Motors Motor NP (Standard+Oversized) Motor RPM iStandard/Ovend Motor Freels &reiSlendard/Ovetatzed) 6.77 low Median liar Lew Medium', High law Median° HO 60.000 80.000 130,000 60,003 80,000 130,000 8040) 120,000 150,000 47400 83.000 103,000 48.000 64,000 101.000 64.E 97,200 121,500 81 81 80 81 81 80 8t 81 81 81 81 80 e1 81 80 81 81 81 2 2 3 2 2 3 2 3 3 1 1 1 1 1 1 1 2 4.5/14.0 4.5/14.0 4Sr1Q.0 10.0/14.0 10.0/14.0 1013114.0 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 1/Scroll 1/SCroll i/SCroll 84 84 lanced Lanced nc 0.3125 03125 0taaoe5 8.81 8.81 13.883 2/17 2/17 17 lanced nc 0.3125 0.3125 :.3125 0.3125 0.3125 5.00 5.00 9.89 3/16 3/16 2/16 Short Orifice Short Orifice Short Orifice 1/44 NFT IPA NPT 1/$4 NPT Propeller premia Baer 1/22 1122 1/26 Oirect/1 Oft ect/1 0 3,470 3,470 6,100 1/033 10.3r 1/0.701' 1875 1.075 1475 Fir Centrifugal FCeCentrif tgal WA Direct/2 Dlreee2 N/A 1 1 0.90/1.00 0.90/1.0010 NA 985/1,!)80+ 885/14800 TWA A 48/48 48/48 N/A Belt Woe Indoor Fen -Type No. Used/Diameter Poi DrtveTypeNo. Speeds No. Motors Motor HP (Standard/Crashed) Motor RPM (SteiximdAOvsized} General Data (5 - 6 Tons} Standard Efficie cy Bron Convertible VSUOSOA1 1 YSC060A3 A4 AW, AK —FC 1/11 x11 B%WWartabte Sheave 1 too, - 1,75W — Motor FremeSize <Standard Ove d) 481— Fllees -Type Furnished' Throwaway lbroativeay No.) Size Reoomnletxted (2) 20 x 25 x 1e (2)20 x 2Sx1" 1RetrtezerteCharge { the ofR-22P 4.7 4S 71 Notes: i 1. Coding Perfomancebrated at65Fatr ier1t,80Fertteringdrybut.67Fenterirguvetbulb.GrosseareeitydeednotincludeAregffactoffanmot rhest.ARlcaaacityisnetandincludes the effect offan motor heat. Unita ere suitable far apertiontds20% canominalcim.UnitsarecertifiedIneccordanoeMiltareUnitaryAlr-ConditionerEgtripmenteertiGcationpmgrarn which is based onARlStandard 710/240e dept AKgeOV/80Halunits. Z EER aattior SEER are rated at MI oondillon8 a nd in accorthince vAill 00E tent procedures. a Untag/mad Part Lend Value brated inecoo rtcewwithAAl$tandard210/240x380.Unitseraratedat80•Fambinn6 Fentering dry hub. and 6TFentering wetbuibatAMrsteddm• ¢ Heating Performance lintsettings and ratirgdate were eatabl'rlhodondapprwmdunder laboratory test conditionsusingAmericanNadawlStandardsinstitutestandards• Ratings shown are for etevadarsup to 2000Jieet For elevations above 2000feet, ratings should be reduced at the rete of 4% for each 1000 feat above gas level ' S - APUEis rated M accordance with OOE test Procedures. 6. Outdoor Sound Rating ahownistested In� rem wfthARI Standard 270.For additional hd�rrtadonreforrmTa PP0.y0, 7. Refrigerant charge is enappnprimatevalue. a man precise vabre,see unit namotlleoend serviceinstviceans. 9. YSL1160At,3,4,WOverehedMotaand KStandard Mater Fan Otametaria12x11. 9 Motor RPM shown Is low speed. MO speed RPM is t t 00ft 136 10. filter size shown is for towand median heat modes. High hoot model finer site recommended is 20x30 x 1, 11.Optbnal Y pleated fitters afro evalsbte. I 12.Y$C072A wfrenumdin8botifomatappicajionhesenEER 01lOiend System Power t44Mof6.81, 13, Medium heat i4 not eve/able forAK 1386V/612Ht1 wills. 14.Outdoor motorta0.78hefor AK1380 6010iunits. 16.Outdoor nrotcrb0A0too forAK ammo Hz) umla. 16.Stamford Matwis1.00hpforYSC060AK38bV/60}fdwins, 17. Standrd Motris2.00hpforthaYSCO7 (3601.160144unhe. 6Ton Convertible YSC072A3,A4, AW. AK FC Centrifuge! 1/12x12 Bal artebia Sheave 1.Ofp2A0" 1.751.750 56156 ThrouensV 14)16x25x2 18 RT-PRCA06.EN Proiect Parkway Village Prepared By: Performance Summary For 5t Unit Part Number:5OKCQAO A2A5.OAOAO ARI SEER' Buse Unit Dimensions Unit Length' Unit Width: Unit Height- Operating eight Operating Weight Base Unit Weight..._..._._......___._...._ �_........_.___._._._....... Medium Static Option Belt Drive:....... Accessories 7.9/9.6/10.5 kW 2081230/240- /3.60 Volt Electric Heater:. Single Point Kit..__..._-•--.-_..._.. _......_--•----_-..-- - Total Operating Weight:. 14.30 74.4 in 46.8 in 41.4 in 610 lb .......... ib 30 lb 10 ib 660 ib Unit Unit Voltage -Phase -Herts:.._..._...__...__.__ ---• - - _.. 20860 Air Discharge'.. Vertical Fan Drive Type .__..__.._...._._....._.. _.. _ . _. . -..._........._........._.,Bert Actual Airflow 20110 Site Altitude:....__._._._..._..__.._.._._._.... 0 CFM ft Cooling Performance Condenser Entering Air DB:..___ -_.-. . _ ......_.__......................__._---___........__. . 95.0 F Evaporator Entering Air DBS....__ _......._.__......._.._....._ 80.9 F Evaporator Entering Air ..... 67.0 F Entering Air Enthalpy: ._.._..__ _--. .._...._...._31.44 BTU/ib Evaporator Leaving Air OB _..._._._._.._ _ 60.11 F EvaporatorLeaving Air WB_......_...._.......____.........__._.._...._........._...__..._.._....._..._..._....._............._......._ ._ 58.1 F Evaporator Leaving Air Entire! _ _...._......... _.__..._ .................._....._...__......._.._.___..2!1.12 BTU/lb Gross Cooling Capacity:._...__.._..___......_.._._. 58.83 MBH Gross Sensible Capacity _.._.._........_..._.-_.._... 43.20 MBH Compressor Power Input_..._.._._ ._._.. 4.79 kW Coil B _.__._...... _... _.._ ypass Factor ......._.._.-.._...-_._ _._.__.._..._......_..--_ .._.._ .................... -_....._..........._... 0.166 Hosting Performance Outdoor Ambient Temperature: Entering Air Indoor Coil OB:....._ Leaving Air Indoor Coil DB. __..__...._....._..._..-.--._._.._.._ 95.9 F Total Heating Capacity: _....--.._-..._.�...._.........._._..__.._ --.._.._..............----......_....._.__.._....._............___._._..._..65.90 MBH Integrated Heating Capacity __....-------_........._. _..... 55.90 MBH Heating Power input_...__.._.....__. _.._._._.__. __.... 4.07 kW HSPF:.._._.._.. --- - - .&2 Electric Heating Capacity:- --._ ._.._.._.. 15.8 O kW Unit Leaving Air Temp:......._...__. __.. _ _.._ _ _ . ......_._.__.__.._ 120.8 F Supply Fan External Static Pressure:........__.___.._.._...._....._._...._..._..._.__.___........... _... 0.50 in wg Options / Accessories Steric PreSsure ElectricHeaters .__._.._.._.__....___._._..___._.-...._........____...__.___._._.._......._...._......---._ _........._..___........._......._......0.17 in wg Total Application Static (ESP + Unit Opts/Ac..._........__._.._..._.._...__.._..__......_._......__..._..._...__..........---..0.67 in wg FanRPM:...._..._._.._ ..................__. ___.1......_......._ 1182 FanPower... - -_.._._...._......._....._....._..._..._..__....... - 1.22 BHP TE .---._._..___-•-•- Selected iFM RPM Range: 1066 -1380 47.6 F 70.0 F Electrical Data Voltage Range;_.._ .._..,...._.__.._ Compressor#1 RIA: Packaged ' • . op = Wider .49 187 - 283 15.9 07/18/2017 07:42AM Page 10 of 14 84 3"JJAite c)"1„ Pte, 74(14 Slot' 133. 205' `4' co,tz ervt,, . A 164 /04 44%1 gec 14,t, 551 4( 441 44 vw,mk(: ,) scat Moore Engineering Group PROJECT: Cetwi ENGR: .\Y.f tY" I DATE: 6/1/17 SCALE: SHEET 2/1/2018 City of Tukwila Department of Community Development DAWNA PETET 899 W MAIN ST AUBURN, WA 98001 RE: Permit No. M17-0109 RED WING SHOES 17135 SOUTHCENTER PKWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/13/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it: is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/13/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ache le Ripley Permit Technician File No: M17-0109 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 r'ERMIT COORS COPY, PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0109 DATE: 08/11/17 PROJECT NAME: RED WING SHOES SITE ADDRESS: 17135 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ,-� 4wc 17 frJ A'/A- Building Division Fire Prevention Planning Division ❑ Public Works ❑ Structural Permit Coordinator • PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/15/17 Structural Review Required REVIEWER'S INITIALS: DATE: El APPROVALS OR CORRECTIONS: DUE DATE: 09/12/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: BIdg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 IECS INC Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 3 A -Z Index Help My L&J Workplace Rights Trades & Licensing IECS INC Owner or tradesperson Principals HUMPHREY, GEORGE, PRESIDENT Doing business as IECS INC WA UBI No. 601 639 846 PO Box 19252 SEATTLE, WA 98109-1252 206-939-9495 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. IECS***044QL Effective — expiration 11/13/1996-11/20/2018 Bond No bond accounts during the previous 6 year period. Insurance Active. Meets current requirements. Nationwide Mutual Ins Co $1,000,000.00 Policy no. ACPACT07555636456 Received by L&I Effective date 08/01/2017 08/01/2017 Expiration date 08/01/2018 Insurance history Savings (in lieu of bond) $6,000.00 Received by L&I Effective date 11/20/2001 11/20/2001 Release date Impaired date N/A N/A Savings account ID Savings history Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601639846&LIC=IECS * * * 044QL&SAW= 9/5/2017 IECS INC License Violations No license violations during the previous 6 , period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 845,304-01 Doing business as SEATTLE MECHANICAL Estimated workers reported Quarter 2 of Year 2017 "11 to 20 Workers" L&I account contact T4 / ALISON WOODWARD (360)902-4629 - Email: WOAL235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 06/14/2016 Inspection no. 317939701 Location 6428 California Ave SW Seattle, WA 98109 Inspection results date 03/31/2015 Inspection no. 317935645 Location 13028 Interurban AVE Tukwila, WA 98178 Inspection results date 04/09/2013 Inspection no. 316583194 Location 940 NE Park Dr Issaquah, WA 98029 Inspection results date 12/11/2012 Inspection no. 316257716 Location 3325 South 116th Building #2 Seattle, WA 98168 Inspection results date 04/10/2012 Violations Violations Violations Violations Violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601639846&LIC=IECS* * *044QL&SAW= 9/5/2017 IECS INC Inspection no. 315954495 Location 300 Park Ave Bremerton, WA 98337 Page 3 of 3 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601639846&LIC=IECS* * *044QL&SAW= 9/5/2017