HomeMy WebLinkAboutPermit M17-0117 - KITANDA - DIFFUSERS, AIR BALANCE SYSTEM, EXHAUST FANKITANDA 436 SOUTHCENTER MALL EXPIRED 03/06/18 M17-0117 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov 9202470010 436 SOUTHCENTER MALL Project Name: KITANDA MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: M 17-0117 9/7/2017 3/6/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 KAYLENE NELSON 1221 SECOND AVE N , KENT, WA, 98032 HERMANSON COMPANY LLP 1221 2ND AVE N , KENT, WA, 98032- 2945 HERMACL005B1 Phone: (253) 359-7147 Phone: (206) 575-9700 Expiration Date: 8/25/2018 DESCRIPTION OF WORK: RELOCATE (6) DIFFUSERS AND AIR BALANCE SYSTEM. INSTALL (1) NEW GENERAL EXHAUST FAN WITH PLENUM DISCHARG E Valuation of Work: $4,200.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $272.04 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: *— Date: 9--)-(7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: a SL Date: 9. 7-/ 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. SIM 41 VI Project No. Date Application Accepted: 1 I Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 2Q6 Southcenter Mall, Tukwila, WA 98188 Tenant Name: Kitanda PROPERTY OWNER Name: Kaylene Nelson Name: Kitanda City: Kent State: WA Zip: 98032 Address: 12700 124th St NE Email: kaylene.nelson@hermanson.com Cin': Kirkland State: WA Zip: 98034 CONTACT PERSON — person receiving all project communication Name: Kaylene Nelson Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Email: kaylene.nelson@hermanson.com Suite Number: 1005 Floor: New Tenant: ❑ Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Ave N City: Kent State: WA zip: 98032 Phone: (206) 575-9700 Fax: (206) 575-9800 Contr Reg No.: HERMACL005BJ Exp Date: 08/25/2018 Tukwila Business License No.: 602004844 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Relocate [6] diffusers and air balance system. install [1] new general exhaust fan with plenum discharge. 4,200 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric 121 Gas ❑ Other: H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 6 Floor furnace Suspended/wall/floor mounted heater 1 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 6 Evaporator cooler Ventilation fan connected to single duct 1 Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 6 Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR UTHORIZED AGENT: Signature: fQ 4 /h_ OATS)._ � Print Name: Kim Lange Day Telephone: (206) 573-2023 Date: 08/18/2017 Mailing Address: 12212nd Ave N H:\Applications\Forms-Applications On Line12011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Kent WA 98032 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY I PAID PermitTRAK $558.16 M17-0117 Address: 436 SOUTHCENTER MALL Apn: 9202470010 $272.04 Credit Card Fee $7.92 Credit Card Fee I R000.369.908.00.00 0.00 $7.92 MECHANICAL $253.96 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $170.02 PLAN CHECK FEE R000.322.102.00.00 0.00 $50.79 TECHNOLOGY FEE $10.16 TECHNOLOGY FEE 1 R000.322.900.04.00 0.00 $10.16 PG17-0100 Address: 436 SOUTHCENTER MALL Apn: 9202470010 $286.12 Credit Card Fee $8.33 Credit Card Fee R000.369.908.00.00 0.00 $8.33 PLUMBING $267.11 PERMIT FEE R000.322.100.00.00 0.00 $180.54 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $53.42 TECHNOLOGY FEE $10.68 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12171 R000.322.900.04.00 0.00 $10.68 $558.16 Date Paid: Friday, August 18, 2017 Paid By: KIMBERLY LANGE Pay Method: CREDIT CARD 415885 Printed: Friday, August 18, 2017 11:10 AM 1 of 1 CiriPWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Kr ®/ Type of Inspection: Rbr1--# MOCIMM 61' (-- Address: Pie 55 r7CCi �i4 Date Called: Special Instructions: Date Wanted: fo ,3-!7 a.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: OK_ R U( -It wt; cNJ1 Ck �- Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2/1/2018 City of Tukwila Department of Community Development KAYLENE NELSON 1221 SECOND AVE N KENT, WA 98032 RE: Permit No. M17-0117 KITANDA 436 SOUTHCENTER MALL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/6/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at Least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/6/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ipley Permit Technician File No: M17-0117 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0117 DATE: 08/21/17 PROJECT NAME: KITANDA SITE ADDRESS: 436 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: q42-41 Building Division Public Works Ezi io/A- Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 08/22/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 09/19/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: w18/2013 HERMANSON COMPANY LLP Home Espanol Contact Safety & Health Claims & Insurance CWashington State Department of k Labor & Industries Search L&I Page 1 of 3 EA A -Z Index Help My Workplace Rights Trades & Licensing HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No. 602 004 844 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County Business type Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. HERMACLOO5BJ Effective — expiration 01/11/2000— 08/25/2018 Bond WESTERN SURETY CO Bond account no, 929381801 $12,000.00 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 9/7/2017 HERMANSON COMPANY LIP Insurance Valley Forge Ins Co Policy no. 6043050846 $1,000,000.00 Received by L&I Effective date 08/18/2017 08/21/2017 Expiration date 08/21/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ......................................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ......................................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 409,648-01 ................................. Doing business as HERMANSON COMPANY LLP Estimated workers reported Quarter 2 of Year 2017 "Greater than 100 Workers" L&I account contact T4 / NIKKI BUTLER (360)902-4918 - Email: BUTQ235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 02/23/2016 Inspection no. 317939295 Location 15580 NE 31st St. Redmond, WA 98052 Inspection results date 05/21/2015 Inspection no. 317935231 Location 4480 154th PI NE Redmond, WA 98052 Inspection results date 12/10/2014 Inspection no. 317424935 No violations No violations No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 9/7/2017 A AC ACH ACT AD ADD'L AFF AFG AHU ALUM AMP/AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTUH CAP CBD CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DDC DEFL DEG DIA DMPR DN DOAS DWG EXH EA EAT EC EER EF EFF EL ELEC/ELECT EMCS ENT EQUIP ESP EWT EXIST EXH F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT R/ G GA GALV GC GPM GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX HZ MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL CEILING TILE ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN / BLACK STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CALIBRATED BALANCING DAMPER CONTROLS CONTRACTOR CEILING DIFFUSER/CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT/CONNECTED/CONNECTION CONTINUOUS/CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC/CONDENSER UNIT DOMESTIC COLD WATER/CONDENSER WATER DUCTBOARD/DRY BULB/DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/DEGREES DIAMETER DAMPER DOWN DEDICATED OUTSIDE AIR SYSTEM DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL/ELECTRIC ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING EXHAUST FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE/SMOKE DAMPER FOOT/FEET FUTURE FACE VELOCITY GRILLE GAUGE/GALLON GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE/REGISTER/DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HERTZ BC CW D E EER MC N N WG PLV KW LAT LB/LBS LF/LIN FT LPG LPS LVG LWA LWG LWT MAX MAU MBH MCA MD MFR MISC MIN MPS MT MTD MUW NA NC NG/NGAS NIC NO NPW N -R OA/OSA OBD OD PCF PD PH POC P/PRESS PSI PSIG QTY R RA RD/RND REF REQ RESID RF RG RL RPM RS S SA SAT SD S/D S_C SEER SENS SL SM SPEC SO SOG SP SF SS STRUC TA TEMP TBD TOD TOS TOT TSP TSTAT TYP UH UNO V VD VEL VERT VFD VOL W WB WG W/O W/SF WSEC NTERNATIONAL BUILDING CODE NDUSTRIAL COLD WATER NSIDE DIAMETER/DIMENSION NVERT ELEVATION NTEGRATED ENERGY EFFICIENCY RATIO NTERNATIONAL MECHANICAL CODE NCHES NCHES WATER GAUGE NTEGRATED PART LOAD VALUE KILOWATTS LEAVING AIR TEMPERATURE POUND/POUNDS LINEAL FOOT/FEET LIQUID PROPANE GAS LOW PRESSURE STEAM LEAVING SOUND POWER RATING LEVEL (IN DB) LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM MAKE UP AIR UNIT 1000 BRITISH THERMAL UNITS/HOUR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MANUFACTURER MISCELLANEOUS MINIMUM/MINUTE MEDIUM PRESSURE STEAM MOUNT MOUNTED MAKE-UP WATER NOT APPLICABLE NORMALLY CLOSED/NOISE CRITERIA NATURAL GAS NOT IN CONTRACT NORMALLY OPEN/NUMBER NON -POTABLE WATER NON-RESIDENTIAL OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIAMETER/DIMENSION POUNDS PER CUBIC FOOT PRESSURE DROP PHASE POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANTITY RETURN GRILLE/RELOCATED/RETURN RETURN AIR ROUND REFERENCE REQUIRED RESIDENTIAL RELIEF REFRIGERANT DISCHARGE GAS REFRIGERANT LIQUID REVOLUTIONS PER MINUTE REFRIGERANT SUCTION SUPPLY SUPPLY AIR SATURATION/SUPPLY AIR TEMPERATURE SMOKE DETECTOR SLIP & DRIVE CONNECTION SEATTLE CODE SEASONAL ENERGY EFFICIENCY RATING SENSIBLE SOUND LINED SHEET -METAL SPECIFICATION SCREENED OPENING SLAB ON GRADE STATIC PRESSURE SQUARE FEET STAINLESS STEEL STRUCTURAL TRANSFER AIR TEMPERATURE/TEMPORARY TO BE DETERMINED TOP OF DUCT TOP OF STEEL/TOP OF SLAB TOTAL TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNIT HEATER UNLESS NOTED OTHERWISE VOLT VOLUME DAMPER VELOCITY VERTICAL VARIABLE FREQUENCY DRIVE VOLUME WRAPPED DUCT WET BULB WATER GAUGE WITH WITHOUT WATTS PER SQUARE FOOT WASHINGTON STATE ENERGY CODE MECHANICAL LEGEND i-io"motx1 210"X 10"® -[-io"xio";)( 10"X10"© .t10"X 10"VI z10"X 10"izi f10"X10"1,, 1 ,10"X10"0 12"X10"or b 12"X10"� ;,-7) -t1 O"0"- 1DIz 1F 10"� 10" 0 k 10"0.1 k 2 10"01 2 10"0i D' I 2 D 2 (s) RECT SUPPLY AIR DUCT UP/TOWARD RECT SUPPLY AIR DUCT DN/AWAY RECT EXHAUST OR RETURN DUCT UP/TOWARD RECT EXHAUST OR RETURN DUCT DN/AWAY ROUND DUCT - UP/TOWARD ROUND DUCT - DN/ AWAY FLATOVAL DUCT - UP/ TOWARD FLATOVAL DUCT - DN/ AWAY DUCT OVERLAP BOOT TAP 45' TAP VOLUME DAMPER CALIBRATED BALANCING DAMPER RISE(R) & DROP(D) TRANSITION TURNING VANES/SPLITTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW (FORCED AIR) 111111111•Eilliffir pcx-fc_rotsq CD /X\ ##"0 ##x##"0 CD1-100 8"0 T T'STAT/TEMP SENSOR H HUMIDITY SENSOR sD SMOKE DETECTOR sP STATIC PRESSURE SENSOR ©OCCUPANCY SENSOR COMBINATION FSD FIRE DAMPER SMOKE DAMPER MOTOR OPERATED DAMPER ACCESS DOORS SOUND TRAP FLEX CONNECTION ACOUSTICALLY LINED DUCT OD = OUTSIDE DIMENSIONS SL = SOUND LINING (THICKNESS) FABRIC DUCT CLEARANCE SUPPLY AIR DIFFUSER (WITH CORE BLANKOFF/ROTATE) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) REVISION CLOUD & TRIANGLE ROUND DUCT SYMBOL FLATOVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE -CFM SIZE -ME t I D z z z z z---CHWs/CHWR-5 RL/RS- 5 ANG -- 5 z- LPG -5 z-CDWS /CDWR-5 z- HWS /HWR-5 COND -5 FOV -5 z- FOS /FOR -5 RDG -5 co CARBON DIOXIDE SENSOR co CARBON MONOXIDE SENSOR QQ SENSOR EXISTING DUCTWORK DEMO DUCTWORK WALL -MOUNTED GRILLE PIPE ELBOW UP PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP PRESS REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY/RETURN REFRIGERANT LIQUID/SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY/RETURN HEATING WATER SUPPLY/RETURN CONDENSATE FUEL OIL VENT FUEL OIL SUPPLY/RETURN REFRIGERANT DISCHARGE GAS MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 WSEC, 2015 IMC, & & SIMILAR YEAR WAC 296-104 BOILER RULES. 2. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNO. 3. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEEPRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNO. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE OUTSIDE DIMENSIONS BEFORE SOUND LINING HAS BEEN ACCOUNTED FOR (SOUND LINING CO 1", UNO) 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY VENTS, STREETS, LOADING DOCK, NEIGHBORING LOT LINES & FUEL BURNING EQUIPMENT OR 3 FEET BELOW OR 25' ABOVE ANY CONTAMINANT SOURCE WITHIN 10 FEET. 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING PER C403.3.1 & C403.2.4.7: - 0% TO 100% OF THE DESIGN SUPPLY AIR WITH FAULT DETECTION & DIAGNOSTIC REPORTING. - CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. -INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE CLASS 1 AND EQUIPPED WITH MOTORIZED (OR GRAVITY PER EXCEPTIONS IN C403.2.4.3) DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, UNO FOR SMOKE CONTROL SYSTEM OPERATION 13. THE CONTROL SYSTEM SHALL MEET C403 AND BE PROGRAMMABLE, CAPABLE OF BEING SET FOR DIFFERENT DAY TYPES PER WEEK, SETBACKSTEMPERATURES WITH OPTIMALISTARTOCONTROLNCONTROLTSYSTEMHSHALLTINCLUDE COOLING O MICROPROCEOSSOR AND BE CAPABLE OF VARYING FLOWS AND RESETTING SUPPLY AIR & WATER TEMPERATURES BY REPRESENTATIVE BUILDING LOADS WHERE REQUIRED IN C403.4. 14. WHERE REQUIRED BY C408, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING >2000 CFM (INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH A TOTAL SUPPLY >2000 CFM) OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. VAV BOX (WITH FAN) SHUTDOWN CAN BE THROUGH CONTROLS SYSTEM. 20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" OR PRESSURIZED SHAFTS/ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS & CORNERS SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE CONSTRUCTION SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE. -ANY PENETRATIONS OF THE CONSTRUCTION (DUCTWORK CONDUIT PIPING) SHALL BE SEALED ON BOTH SIDES -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS AND THRESHO D SWEEPS, AND OPEN AGAINST THE DIRECTION OF PRESSURE. -USE SECTION 909.5 OF THE 2012 IBC FOR MAX ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. 23. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS USED DURING THE INSTALLATION/FINISH WORK SHALL MEET THE LEED REQUIREMENTS FOR IEQ. 24. MAXIMUM STANDARD LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET; UP TO 25' MAXIMUM LENGTH IS ACCEPTABLE IF; REFER TOTII�ISTALLATION SDETAILS NOT 'SUPPORTOREQUIREMENTS D FLEX BLE INCREASED CRT FLAM RSPRENADMRATINGI SHALLBBED< 2O NOT EXCEED DEVELOPEDL. RATING SHALL BE < 50. USE THERMAFLEX MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 25. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. 26. C406 "ADDITIONAL ENERGY PACKAGE OPTIONS" AS APPLICABLE. MINIMUM DUCT INSULATION LAST UPDATED 07/11/16 DUCT TYPE DUCT LOCATION (IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM) INSULATION R -VALUE REMARKS SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: OUTSIDE BUILDING R-8 1,2,3 OUTSIDE AIR WITHIN CONDITIONED SPACE: INSIDE BUILDING SEE NOTES 4 & 5 1,2,3,4,5 SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING R-6 1,2 SUPPLY AIR <55° OR >105° WITHIN CONDITIONED SPACE R-3.3 1,2 1 REFER TO C403.2.8 FOR FURTHER REQUIREMENTS & ALSO R403 FOR RESIDENTIAL INSTALLATIONS 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.8.1 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (AND Z" THICK INSULATION MIN. TO PREVENT CONDENSATION ON DUCTS IN PLENUM UP TO THE HEATING OR COOLING EQUIPMENT) 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND <2,800 CFM SUPPLY AIR 141EPUNIUNI KM INSULATIONLAST UPDATED: 07/11/16 FLUID DESIGN OPERATING TEMP °F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH) CONDUCTIVITY RANGE MEAN TEMP RATING °F <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION) N/A 0.21-0.27 75 0.5 0.5 0.5 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 <40 0.20-0.26 75 0.5 1.0 1.0 1.0 1.5 NOTE: * NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA. ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED SEE R403 FOR RESIDENTIAL INSTALLATIONS. DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION M0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC M2.01 PARTIAL 1ST FLOOR PLANS & SCHEDULE - HVAC Hermanson Building Today, Defining Tomorrow REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ APN NUMBER 9202470010 LEGAL DESCRIPTION WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP #L10-032 REC #20101021000765) KITANDA ESPRESSO AND ACAI TI WESTFIELD SOUTHCENTER 2800 SOUTHCENTER MALL, SUITE 1005 TUKWILA, WA 98188 i PJ 1;1, :I ..:F:,.. i4o. x,.11-�_ oflrmit Ian review approval is subject to errors and omissions. Approval of'canstruction d cuts does not authorize pt the violation of any meted code or ordinance. R of approved Field Copy and'conditions is acknowledged: urvT'-t: 4 Date: Ardpvpl .7 City" of Tukwila --....1,1,,,.1. 366o Southcenter Ma41 5s'"• � iLDING DIVISION • VICINITY MAP Revisions 08/18/17 JMH ISSUE FOR PERMIT No. Date By Description Design Design Team JMH Drawn FVP Checked DTN Pre -Construction Number 11-17-11293 Construction Number Issue Date 08/18/17 SEI- F_ PERMIT f 0,iiiRED FOR: 1 0 Mechanical (3 lectrical tumbing Gas Piping ;:;:_;r of Tukwila Ri01..r`;P.JC DIVISION LEGEND, ABBREVIATION, GENERAL NOTES & SHEET INDEX- HVAC SITE MAP v ;t1 'R `} , D FOR APPROV gQDE COMPLIANCE AN 3 O UV (ifig City of Tukwila t?I% ION ISSUE FOR P R CEIVED CITY OF TUKWIL AUG 2 4 X017 PERMIT CENTER M0.00 Z__J �L 1 1 J I L (1) (� N // �\ 2/> / / i ' \ ' -- / // / \./ \ ,/ \\ �/ / ( l << \ \ / \• \ \ //// / 0 \ J \\ / / / I \\\ ff IN 0 \� fl1 17, { I LJ 0 1\1 II 0 1 r.1 f I f / // 1/ C. I PARTIAL 1ST FLOOR DEMO PLAN - HVAC SCALE: 3/16" = 1'-0" a/,iiia/ PARTIAL 1ST FLOOR PLAN - HVAC SCALE: 3/16" = 1'-0" 1, t EXHAUST FANSCHEDULE LAST UPDATED: 8/23/2017 UNIT E.S.P. MAX WEIGHT TAG SERVICE/LOCATION MAKE MODEL NR TYPE CONTROLS CFM IN. W.G. RPM HP V/PH SONES LBS REMARKS EF1-01 AIR PURIFICATION/ COFFEE 4051 CEILING GREENHECK SQ85VG IN-LINE ON / OFF 150 0.500 1512 1/4 115/1ph 7.6 49 1-8 1 FOR TRADE COORDINATION REFER TO APPROVED EQUIPMENT SUBMITTALS 2 PROVIDE WITH BACKDRAFT DAMPER 3 PROVIDE WITH MOTOR MOUNTED SPEED CONTOLLER, INSULATED HOUSING AND BACKDRAFT DAMPER 4 ELECTRICAL WIRING, DISCONNECT AND MOTOR STARTER (AS REQUIRED) BY ELECTRICAL CONTRACTOR 5 CONTROLLED VIA WALL SWITCH (PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR) 6 MOTOR TO BE ECM (OR 70% MINIMUM EFFICIENCY) PER ENERGY CODE C403.2.10.3 FOR MOTORS GREATER OR EQUAL TO 1/12 HP & LESS THAN 1 HP 7 INSTALL PER MANUFACTURER RECOMMENDATIONS 8 FIELD COORDINATE FINAL LOCATION DESIGN NOTE 01 RELOCATE AND MODIFY LINEAR DIFFUSERS ND DUCTS AS REQUIRED FOR NEW CEILING PLAN. KEY PLAN SCALE: NONE REVIEWED FOR LODE COMPLIANCE APPROVED AUG 302017 City of Tukwila BUILDING DIVISION Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ KITANDA ESPRESSO AND ACAI TI WESTFIELD SOUTHCENTER 2800 SOUTHCENTER MALL, SUITE 1005 TUKWILA, WA 98188 Revisions 08/18/17 JMH ISSUE FOR PERMIT No. Date By Description Design Design Team JMH Drawn FVP Checked DIN Pre --Construction Number 11-17-11293 Construction Number Issue Date 08/18/17 RECEIVED CITY OF TUKWILA AUG 2 4 2017 PERMIT CENTER ISSUE FOR PERMIT