Loading...
HomeMy WebLinkAboutPermit M17-0124 - SEE'S CANDIES - RTUS, DUCTWORK, GRILLES, DIFFUSERSSEE'S CANDIES 17100 SOUTHCENTER PKWY SUITE 108 M17-0124 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT 7888920020 Permit Number: 17100 SOUTHCENTER PKWY 108 Project Name: SEES CANDIES Issue Date: Permit Expires On: M17-0124 1/11/2018 7/10/2018 Owner: Name: Address: WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE, CA, 98006 Contact Person: Name: RICHARD ESCALANTE Address: 3434 S LA CIENEGA BLVD , LOS ANGELES, CA, 90016 Contractor: Name: EMERALD AIRE INC (CONSTRUCTION) Address: 5108 D ST NW , AUBURN, WA, 98001- 2418 License No: EMERAAI055BL Lender: Name: Address: Phone: (310) 993-9635 Phone: (253) 872-5665 Expiration Date: 4/1/2019 DESCRIPTION OF WORK: 2 EXISTING RTU'S ARE TO BE REUSED. EXISTING RTU -1 WITH REUSE OF THE EXISTING SUPPLY AIR MAINS AND ADJUSTED DUCTWORK RUNOUTS TO NEW DIFFUSERS/GRILLES. EXISTING RTU -2 TO HAVE ALL NEW DUCTWORK WITH ASSOCIATED GRILLES/DIFFUSERS. NEW CEILING MOUNTED TOILET EXHAUST FAN WITH ASSOCIATED DUCTWORK Valuation of Work: $75,000.00 Type of Work: Fuel type: GAS Fees Collected: $1,204.28 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 NktilPermit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development pe trait and free to the conditions atta •d to this permit. Signa Print Dame: Date:a1/ 1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL �Y. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. " I M / v Iv+ Project No. Date Application Accepted: 'J Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: Southcenter Square - 17100 Southcenter PKWY Suite Number: 108 Floor: 1 New Tenant: ❑ Yes ®..No Tenant Name: Sees Candies PROPERTY OWNER Name: RICHARD ESCALANTE Name: DAVID KRUEGER - WIG PROPERTIES Address: 4811 134TH PLACE SE Phone: (310) 993-9635 Fax: (310) 842-4436 City: BELLEVUE State: WA Zip: 98006 CONTACT PERSON - person receiving all project communication Name: RICHARD ESCALANTE Address: 3423 S LA CIENEGA BLVD City: LOS ANGELES State: CA Zip: 90016 Phone: (310) 993-9635 Fax: (310) 842-4436 Email: RESCALANTE@SEES.COM MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ r OW Describe the scope of work in detail: (2) Existing roof top units are to be reused. Existing roof top unit RTU -1 with reuse of the existing supply air mains and adjusted ductwork runouts to new diffusers/grilles. Existing roof top unit RTU -2) to have all new ductwork with associated grilles/diffusers. New ceiling mounted toilet exhaust fan with associated ductwork. Use: Residential: New ❑ Replacement ❑ Commercial: New 0 Replacement 0 Fuel Type: Electric ❑ Gas 0 Other: (2) Existing roof top units to be reused. H:WpplicationsTorms-Applications On Line \2016 ApplicationsVvlechanical Permit Application Revised 1-4-16.does Revised: January2016 bh Page 1 of 2 a Indicate type of mechanical work being installed and the quantity below: Note: (2) existing RTU's are to be reused. No new HVAC cooling/heating equipment. Unit Type Qty Furnace <100k btu 2 Furnace >100k btu 2 Floor furnace 2 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 2 Evaporator cooler 2 Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 23 Thermostat 2 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: -- Date: 09/06/2017 Print Name: TIM BENSON Day Telephone: (608) 785-2760 Mailing Address: 3823 CREEKSIDE LANE HOLMEN WI 54636 H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh City State Zip Page 2 of 2 °or I T74111111 O 190a 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $4,075.13 D17-0234 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020 $2,281.60 Credit Card Fee $66.45 Credit Card Fee R000.369.908.00.00 0.00 $66.45 DEVELOPMENT $2,109.88 PERMIT FEE R000.322.100.00.00 0.00 $2,105.38 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY. FEE $105.27 TECHNOLOGY FEE R000.322.900.04.00 0.00 $105.27 EL17-0686 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020 $1,435.94 Credit Card Fee $41.82 Credit Card Fee R000.369.908.00.00 0.00 $41.82 ELECTRICAL $1,327.73 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,327.73 TECHNOLOGY FEE $66.39. TECHNOLOGY FEE R000.322.900.04.00 0.00 $66.39 M17-0124 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020 $80.46 Credit Card Fee $2.34 Credit Card Fee R000.369.908.00.00 0.00 $2.34 MECHANICAL $33.15 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $44.97 TECHNOLOGY FEE R000.322.900.04.00 0.00 $44.97 PG17-0110 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020 $277.13 Credit Card Fee $8.07 Credit Card Fee R000.369.908.00.00 0.00 $8.07 PLUMBING $256.25 PERMIT FEE R000.322.100.00.00 0.00 $223.10 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $12.81 TECHNOLOGY FEE I R000.322.900.04.00 I 0.00 I $12.81 TOTAL FEES PAID BY RECEIPT: R13154 $4,075.13 Date Paid: Thursday, January 04, 2018 Paid By: RICHARD ESCALANTE Pay Method: CREDIT CARD 062432 Printed: Thursday, January 04, 2018 9:26 AM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK$892.22 PAID M17-0124 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020 $892.22 Credit Card Fee $25.99 Credit Card Fee R000.369.908.00.00 0.00 $25.99 MECHANICAL $866.23 PERMIT FEE R000.322.100.00.00 TOTAL FEES PAID BY RECEIPT: R13155 0.00 $866.23 $892.22 Date Paid: Thursday, January 04, 2018 Paid By: RICHARD ESCALANTE Pay Method: CREDIT CARD 19256P Printed: Thursday, January 04, 2018 9:27 AM 1 of 1 (SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $639.47 EL17-0686 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020 $341.89 Credit Card Fee $9.96 Credit Card Fee R000.369.908.00.00 I 0.00 $9.96 ELECTRICAL - $331.93 PLAN CHECK FEE R000.345.832.00.00 0.00 $331.93 M17-0124 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020, $231.60 Credit Card Fee $6.75 Credit Card Fee R000.369.908.00.00 0.00 I $6.75 MECHANICAL $224.85 PLAN CHECK FEE R000.322.102.00.00 0.00 $224.85 PG17-0110 Address: 17100 SOUTHCENTER PKWY 108 Apn: 7888920020 $65.98 Credit Card Fee $1.92 Credit Card Fee R000.369.908.00.00 0.00 $1.92 PLUMBING $64.06 PLAN CHECK FEE R000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R12285 0.00 $64.06 $639.47 Date Paid: Monday, September 11, 2017 Paid By: PAUL WARREN Pay Method: CREDIT CARD 59433D Printed: Monday, September 11, 2017 9:56 AM 1 of 1 I?SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 41/7-o/2 Project: p -.2C s4✓DY Type of Inspection: /✓ Cc144.AliCi i_ (i Mi - Address: 17/00 c�®v1Mir i? Date Called: Special Instructions: Date Wanted: a.m. 3-8-18 p.m. RequeerAA-A__ E Phone No: b / -112;3 3 pproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 01/7-6/2V PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: i S.i Pig Type of inspection: biCf MiSairri A' Address: Date Called: Special Instructions: Date Wanted: 3-7r /8 a."m. p:m. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: DU i f N SiLi 1 Mi inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. CD INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 f417-a/2t Project: ,Type 5Oig j3, of Inspection: Address: 17100 S'oanticeffirR, kvid Date Called: Special Instructions: Date Wanted: ,2-7-18. a.m: Requester: Re:i3 Phone No: 2 -95 -1987. Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: inspector: t�S Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 MeollaMcai Summary MECH-SUM 201 ! "°4�Y P`''! '' .de Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 P , .. ;� a ,; C r, •� � 38672 • FCt v' p' Project Title: See's Candies at Southcenter Square, Tukwila, WA Date 7/18/2017 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. CITY FIEEt Egiapi®e OF T U K W I L A SEP 1 1 2017 CENTER Company Name: Company Address: Applicant Name: Applicant Phone: PERMIT Project Briefly describe the text box • Total Descri mechamca systems provided Bldg Performance (TBP)701.1„1 includes all mandatory per C401.2 Option 2. MECH-CHK, and C407 Analysis forms required. 1 New Building ■ Building Addition ❑.. Tenant Improvement 1 System Retrofit • No System Changes (2) Existing ceiling gas roof top units to be reused with modified ductwork routing to diffusers/grilles. ReplaLce existing mounted toilet exhaust fan with a new ceiling mounted toilet exhaust fan. ` This path provisions MECH-SUM, Energy Design Load Calculations heating, cooling or includes all applicable 1 Load calculation summary II MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building ventilating needs. If a load calculation summary is provided with the permit documents that compliance information then the MECH-LOAD-CALC form is not required. Mechanical Schedules forms are not required, o Mechanical Plans 1 MECH-EQ Forms (TBD) Indicate location of equipment compliance information. If provided on plans then MECH-EQ however, include on plans all applicable compliance information listed in MECH-EQ tables. IV /A 6>< • R"T kr S 4, ie'"`,.., " . Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and occupied, conditioned areas shall be served by a DOAS that delivers required ventilation require space conditioning fan operation. Space conditioning fans cycled off when no fire station occupancies) air in a manner that does heating or cooling is required. Exception 1) of DOAS (C403.6, Exception library or fire station) C402.4.1.4 with 100% of 1 All not • Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, 1 and space conditioning provided by a HEVAV system per C403.7 in lieu Ventilation DOAS included in project, although not required (occupancy not office, retail, education, DOAS related allowances included in project: • 0 1 Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area in building served by DOAS. 1 Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. 1 IN HVAC Hydronic Systems 1 Hydronic chilled water 1 Water -loop heat pump 1 No hydronic systems II Hydronic heating water MI Geothermal C406 Opti Additional Efficiency ■ 1 C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than minimum requirements. All stand alone supply, retum, and exhaust fans over the must have FEQ z 71 and must be selected within 10% of maximum total or static pressure. C406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% of annual hot water energy use be provided by heat pump, waste heat recovery or solar water -heating systems. n - _ Cil l D FC' CODE COMPLIAiNIC V APPROVED R R }' SEP 18 2017 City of Tukwila BUILDING DIVISION % 1 14 ,A'/" '+ 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary, pg. 2 MECH-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Service Water Heating Systems Commissioning Equipment Type (s) Q Hot water heating tank(s) ❑ Dedicated boiler Distribution Type (s) ❑ Circulation System ❑ Instantaneous U No service water systems ❑ Heat exchange from space heat boiler or central hot water/steam ❑ On -demand Commissioning is required for: ❑ Mechanical systems per C408.2 ❑ Service water heating systems per C408.4 !f required, commissioning shall be performed for all applicable systems regardless of individual equipment capacity. Exceptions to commissioning requirements: ❑ Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h cooling or 300,000 Btu/h heating. Mechanical systems commissioning not required. Capacity of largest service water heating system in building does not exceed 200,000 Btu/h. Service water heating systems commissioning not required. Low Energy and Semi -Heated Spaces Space ;Type (Note 6 and 7) Area Served squerefeet Heating Capacity;•Btu/h (Note 4) Cooling Capacity Btu/h (Note "5) Peak Space Conditioning.:' Capacity ;`, 8tu/h sf Compliance Check Note 4 - Provide total installed heating ou put capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. Enter 0 if no cooling. Note 6 - Refer to Section C402.1.1 Low Energy Building. Intalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h*sf. Note 7 - Refer to Section C402.1.1.1 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h*sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 1 of 2 Service Water Heating Permit Plans Checklist SVVH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: See's Candies at Southcenter Square, Tukwila, WA Date 7/18/2 017 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Equipment - Sizing, Performance and Type Yes C404.2 SWH equipment type and efficiency Provide equipment schedule on plans indicating type and capacity; indicate efficiency complies with required federal standard P2 NA C404.2.1 High input -rated SWH systems For individual SWH equipment serving an entire building with >_ 1,000,000 Btu/h capacity, indicate thermal efficiency 5 90%; or exception taken For buildings with aggregate capacity of all SHW equipment z 1,000,000 Btu/h (exclude < 100,000 Btu/h equipment from threshold calculation), indicate average capacity weighted thermal efficiency 5 90%; or exception taken If applying Exception 1 for site -solar or site -recovered energy, provide calculations and source of annual service water heating energy use estimate Yes C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply and discharge - P2 NA C404.5 Insulation under electric water heater For electric water heaters located in unconditioned spaces or on concrete floors, indicate R-10 insulation under equipment Piping Systems Yes C404.6 Insulation of piping Indicate thickness of piping insulation on plans per Table C403.2.9; verify insulation is provided - from the water heater to the final fixture in a line, from the inlet / outlet piping at water heater to heat trap (up to 8 feet), and on piping that is heat traced; note exceptions taken P1, MP1 Yes C404.3 Efficient SWH supply piping Indicate method of compliance on plans for all piping runs connecting service hot water source to hot water fixture (maximum pipe length or maximum pipe volume method per Table C404.3.1); provide calculations for all piping runs documenting the total length and / or volume P2 Service Water Heating System Controls Yes C404.7.1 0404.8 Heated -water circulating systems For circulation systems with dedicated retum piping, indicate controls are configured to automatically start pump based on demand for hot water and shut-off pump when there is no demand and when the desired water temperature is met P1, P2 For circulation systems with cold water supply piping serving as the retum, indicate controls are configured to automatically start pump based on demand for hot water and shut-off pump when there is no demand, or when temperature of water entering the cold water supply pipe is >_ 104°F NA C404.7.2 Heat trace system controls For heat trace systems provided to maintain temperature of service hot water in piping, indicate controls are configured to de -energize system when there is no demand for hot water and when the desired water temperature is met NA 0404.7.3 Controls for hot water storage For systems with separate water heater and storage tank, indicate controls are configured td limit operation time of pump after end of heating cycle to 5 5 minutes NA 0403.2.13 C403.4.2.7 Variable flow control- pumps For SWH, pool / spa and pressure boosting pump motors 2 7.5 hp, indicate methodof variable flow control (VSD or equivalent method that requires z 30% design wattage at 50% design fluid flow); note exception taken Identify basis of pump speed control (differential or static pressure setpoint, pressure, zone load demand, etc) Pools and Permanent Spas - Equipment and Controls (Sections are under C404.11) NA C404.10.1 Pool heating equipment efficiency Provide equipment schedule on plans indicating type and capacity for all pool heating equipment; indicate efficiency complies with required federal standard; for heat pump water heaters Indicate COP 2 4 NA C403.2.13 Variable flow control - pumps Refer to Service Water Heating System Controls 4- NA C404.10.1 C404.10.2 Pool heater on / off controls Indicate automatic on / off control based on scheduling and readily accessible on / off switch on heater that operates independent of thermostat setting; note exceptions taken NA C404.10.3 Pool covers For all pools and in -ground permanent spas, indicate a vapor retardant cover on plans For all pools and in -ground spas heated to > 90°F, indicate cover shall include insulation >_ R- 12 NA C404.10.3 Pool assembly insulation For all pools and in -ground spas heated to > 90°F, Indicate on plans that sides and bottom are provided with insulation t R-12 NA C404.12 Energy consumption of portable spas Indicate portable spa complies with Association of Pool and Spa Professionals APSP-14 rgy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all K1 - rage -z or z Energy Recovery (ER) Systems - Service Water Heating and Pool Systems NA 0404.10.4 (Section under 0404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or permanent spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by >_ 36°F NA 0403.5.3 Energy recovery - cooler / freezer condensers For buildings with food service, meat or deli departments that have >_ 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate I1 condenser ER will be used to pre -heat service water For buildings with >_ 40,000 sf conditioned floor area and with >_ 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate if condenser ER will be used to pre -heat service water NA 0403.5.4 Energy recovery - condenser systems For buildings with 24-hour operation and > 1,500,000 Bluth of heat rejection capacity and design SWH load > 250,000 Btu/h, indicate condenser ER to pre -heat service water, or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). NA 0404.10 Drain water heat recovery units For systems Incorporating drain water ER, indicate system design complies with CSA B55.2 (or CSA 55.1 for Group R); indicate potable waterside pressure loss at design flow is < 10 psi Service Water Heating Energy Use Metering NA 0404.9 SWH energy usage in dwelling units For Group R-2 multi -family buildings with central SWH systems, provide metering of hot water energy usage per dwelling unit; indicate metering and data reporting method NA 0409.3.2 SWH equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, with total SWH equipment capacity z 50 kW (z 170,600 Btu/h), verfiy energy use metering of all SWH equipment will be provided per C409 Additional Efficiency Package Option, Reduced Energy Use In Service Water Heating - Must comply with both provisions to be eligible NA C406.7.1 Eligible building type To comply with additional efficiency package option, verify that z 90% of the conditioned floor area of the building is one or more of the occupancies identified In this section, OR; Provide whole building energy analysis per C407 that demonstrates the SWH load in the building is a 10% of total building energy loads NA 0406.7.2 0403.5.4 Load fraction To comply with additional efficiency package option, provide documentation that verifies >_ 60% of building annual SWH energy is provided by high efficiency sources (heat pump water heater with COP z 3, waste heat recovery, solar water -heating system); For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and design service hot water load > 250,000 Btu/h (per C403.5.4); provide documentation that verifies z 100% of building annual SWH energy is provided by condenser energy recovery or other high efficiency source Documentation and Specific System Requirements to Supporting Commissioning NA C408.4 Scope of service water heating systems commissioning Indicate that all SWH equipment and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned;+D7 For buildings where the largest SWH system has ? 200,000 Btu/h total output capacity, indicate that all SWH systems regardless of individual capacity are required to be commissioned. NA C408.4.1.3 Scope of pool and permanent spa systems commissioning Indicate that all pool and permanent spa water heating systems regardless of individual capacity are required to be commissioned; Indicate that energy recovery equipment that heats pool water regardless of capacity is required to be commissioned; Identify all pool heating and energy recovery equipment and controls that the WSEC defines as being capable of and / or configured to perform specific functions. NA C404.13 C408.1.1 C408.1.2 0408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate In plans and specifications that Cx per C408 is required for all applicable service water heating systems; Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activites, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of • interest plan (if required); Include in general summary that a Cx project report or Compliance Checklist (Figure 0408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. NA 0408.4.1 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, Including interfacing between new and existing -to -remain systems Project Close Out Documentation NA C103.6 Documentation and project close out submittal requirements Indicate in plans that project close out documentation and training of building operations personnel is required for all SWH components, equipment and systems govemed by this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations �ERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0124 DATE: 09/12/17 PROJECT NAME: SEES CANDY SITE ADDRESS: 17100 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: k5- Aoc Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 09/12/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: i1 10/10/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 EMERALD AIRE INC Washington State Department of Labor & Industries Page 1 of 3 Home • Espafiol. Contact Search L&I A -Z Index Safety & Health Claims & Insurance Workplace Rights EMERALD AIRE INC Owner or tradesperson Principals HAPPE, DOUGLAS A, PRESIDENT RIDGE, JOHN PATRICK, VICE PRESIDENT RICHARDS, RON, SECRETARY (End: 06/01/2000) DUPUIS-FRICKE, LINDA, PRESIDENT (End: 12/31/1999) HAPPE, DOUGLAS A, PRESIDENT (End: 12/31/1999) TREMAINE, DAVIS WRIGHT, AGENT (End: 12/31/1999) Doing business as EMERALD AIRE INC WA UBI No. 600 591 552 5108 D STREET NW AUBURN, WA 98001 253-872-5665 KING County Business type Corporation Governing persons DOUG HAPPE JOHN RIDGE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL Active. Meets current requirements. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600591552&LIC=EMERAAI055BL&SAW= 1/11/2018 EMERALD AIRE INC License no. EMERAAI055BL Effective — expiration 01/13/1995— 04/01/2019 Bond Merchants Bonding Co (Mutual) Bond account no. WA100080 $12,000.00 Received by L&I Effective date 12/29/2016 01/01/2017 Expiration date Until Canceled Bond history Insurance American Fire & Casualty Co $1,000,000.00 Policy no. BKA57677232 Received by L&I Effective date 11/29/2017 12/01/2017 Expiration date 12/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Page 2 of 3 No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 491,003-00 Doing business as EMERALD AIRE Estimated workers reported Quarter 3 of Year 2017 "Greater than 100 Workers" L&I account contact T3 / NATHAN KOZAK (360)902-6243 - Email: KOZN235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600591552&LIC=EMERAAI055BL&SAW= 1/11/2018 • IrTimi ti A-8"0 150 8/12 16 11,0 MECHANICAL NOTES 1. ALL EQUIPMENT, INSTALLATION AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE LANDLORD CRITERIA. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING, PRIOR TO FINAL BID, ALL EXISTING STUB -INS, TAPS, ETC. FOR PLUMBING AND MECHANICAL SYSTEMS WITHIN TENANT SPACE. 3. BRANCH DUCT RUN OUTS TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER NECK UNLESS OTHERWISE SPECIFIED. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO THE LANDLORD'S BASE SYSTEMS. COORDINATE ALL SYSTEMS IN THE FIELD. 6. VERIFY LOCATION OF ANY PENETRATION OF ROOF WITH LANDLORD. ALL ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE BY LANDLORD APPROVED ROOFING CONTRACTOR AT TENANT CONTRACTOR'S EXPENSE. 7. ALL FIRE PROTECTION AND SPRINKLER WORK SHALL BE PERFORMED BY LANDLORD -APPROVED FIRE PROTECTION CONTRACTOR AT THE TENANT'S EXPENSE. 8. CONTRACTOR SHALL SUBMIT CERTIFIED AIR BALANCE REPORT INCLUDING ALL ASSOCIATED AIR TEMPERATURES AND PRESSURES AS APPLICABLE. SEND TWO COPIES TO OWNER FOR APPROVAL. 9. CEILING CONTRACTOR TO PROVIDE ADEQUATE ACCESS IN OPEN CEILING GRID AT DIFFUSER/DAMPER LOCATIONS FOR PURPOSE OF AIR BALANCING. 10. ALL SUPPLY AND RETURN AIR DUCTS IN PLENUM TO BE EXTERIOR INSULATED. 11. REMOVE ALL UNUSED HVAC EQUIPMENT, DUCTWORK, ACCESSORIES AND PIPING. DO NOT ABANDON. VERIFY CONDITIONS IN FIELD. KEYED NOTES O1 EXISTING GAS ROOFTOP UNIT TO BE REUSED. SEE SCHEDULE FOR AIR BALANCE AND REFURBISHING REQUIREMENTS. VERIFY EXACT LOCATION ON SITE. TYP FOR RTU -1 & RTU -2. REPLACETHEHE EXISTINGTOILETEXHAUST FAN WITHA NEW TOILET EXHAUST FAN (EF -1). ROUTE 6" RIGID DUCT W/ BACKDRAFT DAMPER AND ROUTE UP TO THE EXISTING RIGID TOILET EXHAUST DUCT ROUTED UP THRU ROOF. VERIFY SIZE AND ROUTING IN FIELD. INSTALL DUCTWORK AS HIGH AS POSSIBLE AND ADJUST DUCTWORK AS REQUIRED TO AVOID STRUCTURAL ELEMENTS. COORDINATE ROUTING OF DUCTWORK IN FIELD WITH OTHER TRADES PRIOR TO FABRICATING ANY DUCTWORK. VOLUME DAMPER AND SPIN -IN. TYPICAL FOR ALL. FLEX DUCT 5'-0" MAX LENGTH. TYPICAL FOR ALL. RELOCATE THE EXISTING THERMOSTAT (HONEYWELL COMMERCIAL VISION PRO #TB8220U1003) SERVING RTU -1 AS SHOWN ON PLAN AND MOUNT AT 4'-0" A. F. F.. • ROUTE 6"0 RIGID DUCT DOWN TO 12"x12" SUPPLY DIFFUSER TO BE INSTALLED AT LOWER LEVEL GYP. BRD. CEILING AT 8'-0" A.F.F.. REFER TO ARCH. DRAWINGS. O EXISTING SUPPLY AIR DUCTWORK SERVING RTU -1 TO BE REUSED.: CAP, SEAL AND INSULATE ALL UNUSED RUN -OUTS AIRTIGHT. FIELD VERIFY EXISTING CONDITIONS. 9O EXISTING RETURN AIR DUCT SMOKE FOR EXISTING ROOF TOP UNIT RTU -1. FIELD VERIFY EXISTING CONDITIONS. 10 RELOCATE THE EXISTING THERMOSTAT FOR RTU -2 AS SHOWN ON PLAN AND MOUNT AT 4'-0" A.F.F.. COORDINATE WITH SEE'S PROJECT MANAGER FOR POSSIBLE REPLACEMENT OF EXISTING T -STAT WITH A NEW SEE'S CANDIES PROVIDED T -STAT (HONEYWELL COMMERCIAL VISION PRO #TB8220U1003). 11 EXISTING 8"O TOILET EXHAUST DUCT UP THRU ROOF TERMINATED WITH EXISTING ROOF CAP TO REMAIN. VERIFY EXISTING CONDITIONS. 12 REPLACE EXISTING SUPPLY AIR DIFFUSER WITH A NEW SUPPLY AIR DIFFUSER AS SCHEDULED AND LOCATE AS SHOWN ON PLAN. BALANCE EACH DIFFUSER TO AIR VOLUME SHOWN ON PLANS. 13 EXISTING 5 TON GAS ROOF TOP UNIT (YORK MODEL D7CG060) TO REMAIN IN PLACE FOR POSSIBLE FUTURE USE. CAP, SEAL AND INSULATE SUPPLY AND RETURN DUCT DROPS BELOW ROOF JOISTS FROM EXISTING ROOF CURB. VERIFY EXACT LOCATION ON SITE. 14 IF NOT EXISTING, FURNISH AND INSTALL A NEW RETURN AIR DUCT SMOKE DETECTOR FOR EXISTING ROOF TOP UNIT (RTU -2) PER LOCAL CODE REQUIREMENTS. VERIFY EXISTING CONDITIONS IN FIELD. 15 CAP, SEAL AND INSULATE SUPPLY AIR TAKE -OFF NOT BEING REUSED. VERIFY EXISTING CONDITIONS. 16 ROUTE 10"0 RETURN AIR TRANSFER DUCT DOWN TO (2) 24"x12" GRILLES AS SHOWN ON PLAN. TRANSITION AS REQUIRED. EXTERIOR INSULATED ROUND RIGID DUCT (EQUIVALENTLY SIZED) CAN BE SUBSTITUTED FOR RECTANGULAR DUCT SHOWN ON PLANS. (TYP). SEE DUCT SPECIFICATION. ALL DUCTWORK IS TO BE CONSTRUCTED AND SEALED PER IMC 2015. ALL UNEXPOSED SUPPLY/RETURN FROM THE AIR CONDITIONING UNIT SHALL BE WRAPPED WITH A MINIMUM R-6 INSULATION WHERE LOCATED IN UNCONDITIONED SPACES PER WASHINGTON STATE ENERGY CODE). 0C-6"0 50 11 270 A 10"0 '70 MECHANICAL CONTRACTOR SHALL PROVIDE SEISMIC BRACING FOR ALL MECHANICAL EQUIPMENT. DUCTWORK. PIPING ETC. PER LOCAL CODE REQUIREMENTS. __ 4NI 315 B ii 1,260 ri. E CO NM=8____=/= =; 1111111111111711111 NM r 111„ 118. MI MIR IIIIIIII AZ j tat A + ERNI/ All. I. O a ,260 ■ al 11111 imppirr- O 1 is 41, pp 0 44111111110. 111 400 Meg 400 No changes REVISIONS shall be rnade to the scope ithou€ prior approval of TukIvla Building Division. OTE: Revisions will require a new plan submittal and may include additional plan review fees. MECHANICAL SYMBOLS X A-10"0 450 CFM REQUIRED THERMOSTAT SUPPLY DIFFUSER RETURN GRILLE VOLUME DAMPER DIFFUSER TYPE/NECK SIZE ® POINT OF CONNECTION EX EXISTING TO REMAIN so SMOKE DETECTOR ISF ARATE PERMIT I`.E QL$ RE D FOR: Mechanical 4j/electrical TePlumbing [Leas Piping of Tukwila Ela" r. !G DIVISION LE COPY REVIEWED FOR CODE COMPLIANCE APPROVED SEP 1 8 2017 ` , VU1_ City of Tukwila BUILDING DIVISION Permit NO. M 1-- 0 L )1-k Plan review approval is subject to errors and omi. one. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fiel • • py an • condito : •... ac ,‘__ edged: g Date: City of Tukwila BUILDING DIVISION DUNHAM �I Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 wEa dunhameng.com mechanical + electrical consulting engineering PROJECT NO. 0418743-004 MBA Architects, Inc. 3823 Creekside Lane Holmen, WI. 54636 608-785-2760 FAX: 608-785-2750 E—mail: officeOmba—architects.com CLIENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 SEE'S CANDIES 3423 S LA. CIENEGA BLVD. LOS ANGELES, CA 90016 PH: 310/287-4616 FAX: 310/842-4436 SEE'S CONTACT RICHARD ESCALANTE 310/ 287-4616 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785-2760 dote L. 0 To 0 0. .2 0 v c 0 0 > comments PREUM REVIEW 08/16/17 0 PERMIT 8/28/17 0 0 0 0 0 drawn by: DS checked by: GS THIS SHEET CONTAINS: HVAC PLAN RECEIVED CITY OF TUKWILA SEP 1 1 2017 PERMIT CENTER M1 ARCHITECT'S COMMISSION NUMBER 17-725.161 RIGID ROUND BRANCH DUCT W/ EXTERNAL INSULATION WORM DRIVE CLAMPS OR DRAWBANDS AND ADHESIVE DIFFUSER ONICAL TAKEOFF SUPPLY DUCT W/ EXTERNAL INSULATION BALANCING DAMPER W/ LOCKING QUADRANT INSULATED FLEXIBLE FLEXIBLE DUCT, 5 FT. MAX. LENGTH, MAX. ALLOWABLE OFFSET FROM CENTERLINE TO BE HALF OF NECK DIAMETER DIFFUSER/DUCT DETAIL M2 NO SCALE M2 NO SCALE SPACE LOAD CALCULATIONS DESIGN TEMPS SUMMER 85 0.A.D.B. O.A.W.B I.A.D.B. 72 DEG F DEG F 65 DEG F GAINS SOLAR LOAD ROOF LOAD GLASS LOAD 14,025 26,180 3,570 WALL LOAD BTU H BTU H BTU H 8,424 BTUH LIGHTS PEOPLE (SENS) PEOPLE (LAT) 23,865 BTUH 10,000 BTUH 8,000 BTUH MISCELLANEOUS 2,387 BTUH VENT. 610 CFM VENTILATION (SENS) 7,906 BTUH VENTILATION (LAT) 3,986 BTUH SENS. LOAD TOTAL LOAD WINTER OADB 23 DEG F IADB 70 .DEG F 96,356 BTUH TOTAL 108,342 BTUH LOSS 15,775 BTUH 11,985 BTUH 8,424 BTUH 30,964 BTUH 68,622 BTUH EXHAUST FAN TAG MANUFACTURER MODEL NO. TYPE CFM S.P. WATTS VOLTAGE ACCESSORIES EF -1 GREENHECK SP -B110 CEILING 100 .25 80 SEE ELEC BACKDRAFT DAMPER NOTE: TOILET EXHAUST FAN SHALL BE INTERLOCKED WITH TOILET ROOM LIGHT SWITCH. OUTSIDE AIR CALCULATION OUTSIDE AIR CALCULATION BASED ON THE 2015 IMC. AREA #1 - SALES AREA 1104 SQ. FT. X 22 P / 1,000 SQ. FT. 7.5 CFM / PERSON X 21 PEOPLE = 0.12 CFM/SQFT. X 1104 SQ. FT. = AREA #3 - STORAGE AREA 0.12 CFM/SQFT. X 1498 SQ. FT. = VENTILATION: VENTILATION: 165 133 298 180 180 CFM TOTAL:478 CFM VENTILATION EFFECTIVENESS FACTOR BASED ON 2015 IMC SECTION 403.3.1.2 478 (TOTAL VENTILATION) _ 0.8 (VENT. EFFECT. FACTOR) MINIMUM VENTILATION REQUIRED: VENTILATION PROVIDED (RTU -1 & RTU -2): 598 CFM 598 CFM 600 CFM M17 012y DIFFUSER, GRILLE & REGISTER SCHEDULE MARK EQUIP. TAG SERVICE TYPE MODULAR/FACE SIZE NECK SIZE MANUF. MODEL NO.DESCRIPTION EER ® ARI MOUNTING TYPE PATTERN NOTES UNIT WEIGHT (LBS) A SUPPLY SQUARE 24"x24" SEE PLAN TITUS PCS PERFORATED FACE LAY -IN 4 -WAY 1, 2 375 B RETURN SQUARE 24"x24" SEE PLAN TITUS PAR PERFORATED FACE LAY -IN - 1 5.0 C SUPPLY SQUARE 12"x12" SEE PLAN TITUS PCS PERFORATED FACE SURFACE 4 -WAY 1, 2, 3 D RETURN/TRANSFER SQUARE 24"x12" SEE PLAN TITUS PAR PERFORATED FACE LAY -IN - 1 E SUPPLY SQUARE 12" x12" SEE PLAN TITUS PCS PERFORATED FACE LAY -IN 4 -WAY 1, 2 NOTES: 1. ALL GRILLES, REGISTERS & DIFFUSERS SHALL HAVE "WHITE" FINISH. 2. PROVIDE 4—WAY ADJUSTABLE DISCHARGE PATTERN PERFORATED SUPPLY DIFFUSER (ROUND NECK) WITH MODEL EGT EQUALIZING GRID, AG -85 BUTTERFLY DAMPER (ROUND NECK). (NOTE: PER SEE'S CANDIES CRITERIA, THE PERORATED SUPPLY AIR DIFFUSER SHALL HAVE THE PATTERN DEFLECTOR LOCATED IN THE NECK OF THE DIFFUSER AND NOT HAVE THE PATTERN DEFLECTOR PLATE RIVETED TO PERFORATED FACE OF THE DIFFUSER. 3. PROVIDE WITH PLASTER MOUNTING FRAME AS REQUIRED FOR GYP. BRD CEILING. EXISTING ROOFTOP UNIT SCHEDULE (GAS HEAT/ELEC. COOL) MARK MFG/ MODEL DISCHARGE TONS ESP CFM OUTSIDE AIR CFM GROSS COOUNG CAPACITY (MBH) EER ® ARI HEATING CAPACITY AFUE % ELECTRICAL UNIT WEIGHT (LBS) TOTAL SENSIBLE INPUT OUTPUT VOLT/PH/HZ RTU -1 YORK DF078 VERTICAL 6.0 0.5 2520 375 (EX.) (Ex.) (EX.) 80 MBH (EX.) 64 MBH (EX.) 80 (EX.) (EX.) (EX.) RTU -2 YORK D7CG060 VERTICAL 5.0 0.5 2100 225 (EX.) (Ex.) (EX.) 100 MBH (EX.) 80 MBH (EX.) 80 (EX.) (EX.) (EX.) NOTE: MECHANICAL CONTRACTOR SHALL PERFORM SERVICE AND REPAIR OF THE EXISTING ROOF TOP UNIT AND ITS ACCESSORIES AS FOLLOWS, BUT ARE NOT LIMITED TO: ALL COILS, REPLACE THE FILTERS AND BELTS, INSPECT, REPAIR OR REPLACE DRIVES, FAN BEARINGS, MOTORS, CONTROL COMPONENTS, VALVES AND ANY OTHER NECESSARY FOR A COMPLETE AND PROPER OPERATING SYSTEM. THIS CONTRACTOR SHALL ALSO VISIT THE SITE PRIOR TO BIDDING AND VERIFY ALL EXISTING SITE 1. THE CLEAN ITEM CONDITIONS. REVIEWED FOR CODE COMPLIANCE APPROVED SEP 18 2017 City of Tukwila BUILDING DIVISION DUNHAM EI Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 wes dunhameng.com mechanical + electrical consulting engineering PROJECT NO. 0418743-004 MBA Architects, Inc. 3823 Creekside Lane Holmen, WI. 54636 608-785-2760 FAX: 608-785-2750 E—mail: officeOmba—architects.com CLIENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 SEE'S CANDIES 3423 S LA. CIENEGA BLVD. LOS ANGELES, CA.90016 PH: 310/287-4616 FAX: 310/842-4436 SEE'S CONTACT RICHARD ESCALANTE 310/ 287-4616 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785-2760 C me c date L 0 c comments PREUM REVIEW 08/16/17 0 PERMIT 8/28/17 0 0 0 0 0 drown by: DS checked by: GS THIS SHEET CONTAINS: EXISTING MECHANICAL FLOOR PLAN RECEIVED CITY OF TUKWILA SEP 112017 PERMIT CENTER M2 ARCHITECT'S COMMISSION NUMBER 17-725.161 MECHANICAL WORK INCLUDED: EACH CONTRACTOR SHALL VERIFY LANDLORD REQUIREMENTS. BID AND INSTALLATION SHALL BE BASED ON SUCH REQUIREMENTS. DRAWINGS AND SPECIFICATIONS. MECHANICAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL WORK WITH THAT OF OTHER TRADES ON THE PROJECT PREVENTING UNNECESSARY CONFLICTS OR DELAYS DURING CONSTRUCTION. IF FOR ANY REASON EXISTING EQUIPMENT TO BE RE -USED NEEDS REPLACEMENT PARTS, THIS COST IS TO BE COVERED UNDER ORIGINAL CONTRACT AMOUNT AND WILL NOT BE ACCEPTED AS AN EXTRA COST OR EXPENSE. CONTRACTOR MUST INSPECT ALL EQUIPMENT TO BE RE -USED AT TIME OF BIDDING OR NEGOTIATING PERIOD. CONTRACTOR SHALL EXAMINE THE SITE, COMPARE IT WITH DRAWINGS AND SPECIFICATIONS AND BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE SUBMITTING A BID. NO ALLOWANCE WILL SUBSEQUENTLY BE MADE IN BEHALF OF THIS CONTRACTOR BY REASON OF ANY ERROR ON HIS PART. CODES AND STANDARDS: ALL CODES, ORDINANCES, RULES, REGULATIONS, ORDERS, AND OTHER LEGAL REQUIREMENTS WITH WHICH COMPLIANCE IS REQUIRED BY GOVERNING AUTHORITIES SHALL BE ADHERED TO. TENANTS CONTRACTORS SHALL VERIFY WITH HVAC PLAN TO COORDINATE THE REQUIREMENT OF PLENUM RATED FIXTURES, PIPING, WIRING, ETC. FAILURE TO DO SO COULD RESULT IN THE REMOVAL AND REPLACEMENT OF THESE ITEMS AT NO ADDITIONAL COST TO THE TENANT. SCOPE A. THE WORK COVERED BY THIS SPECIFICATION INCLUDES THE COMPLETE HEATING AND AIR CONDITIONING SYSTEM. B. THE WORK TO BE PERFORMED UNDER THE HEATING AND AIR CONDITIONING SPECIFICATIONS AND DRAWINGS CONSISTS OF FURNISHING ALL LABOR AND MATERIAL FOR THE COMPLETE INSTALLATION OF ALL HEATING AND AIR CONDITIONING SYSTEM FOR TENANT SPACE. THE WORK SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO, THE FOLLOWING: 1. HEATING/COOLING UNITS 2. TOILET ROOM EXHAUST SYSTEMS 3. AUTOMATIC TEMPERATURE CONTROL 4. DUCTWORK AND AIR CONTROL 5. USE OF CRANE TO PLACE ROOF TOP EQUIPMENT (WHEN REQUIRED) GENERAL: A. THIS SPECIFICATION IS INCLUSIVE FOR EACH ITEM REQUIRING ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO PROPERLY INSTALL, ALTER, ADJUST, AND PUT IN OPERATION, THE COMPLETE HEATING AND AIR CONDITIONING SYSTEM. B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER LAYOUT AND CONSTRUCTION OF THE WORK INCLUDED IN THIS CONTRACT. LAWS, ORDINANCES AND REGULATIONS: A. ALL SYSTEMS IN ALL AND/OR PART SHALL CONFORM TO ALL PERTINENT LAWS, ORDINANCES AND REGULATIONS OF ALL BODIES HAVING JURISDICTION, AT ALL GOVERNING LEVELS, NOTWITHSTANDING ANYTHING IN THESE DRAWINGS OR SPECIFICATIONS TO THE CONTRARY. IN CASE OF CONFLICT BETWEEN GOVERNING LEVELS, THE MORE STRINGENT LAWS SHALL APPLY. B. THE CONTRACTOR SHALL PAY ALL FEES AND OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY ANY AUTHORITY HAVING JURISDICTION IN CONNECTION WITH HIS WORK. MATERIALS AND EQUIPMENT: A. ALL MATERIALS SHALL BE NEW AND SHALL BE OF THE TYPE AND SHALL MEET THE CAPACITIES OF EQUIPMENT SPECIFIED ON THE DRAWINGS. ALL MATERIALS AND EQUIPMENT UTILIZED SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA. B. ALL EQUIPMENT OFFERED UNDER THESE SPECIFICATIONS SHALL BE LIMITED TO PRODUCTS REGULARLY PRODUCED AND RECOMMENDED FOR SERVICE, IN ACCORDANCE WITH ENGINEERING DATA, RATINGS, OR OTHER COMPREHENSIVE LITERATURE MADE AVAILABLE TO THE PUBLIC AND IN EFFECT AT THE TIME OF OPENING OF BIDS. C. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR TYPE AND CAPACITY OF EACH PIECE OF EQUIPMENT USED. WORKMANSHIP: A. ALL HEATING EQUIPMENT SHALL BE INSTALLED IN A WORKMANLIKE MANNER MEETING THE ACCEPTED STANDARDS OF THE HEATING INDUSTRY. THE WORK SHALL BE DONE BY SKILLED HEATING CRAFTSMAN, AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF ASHRAE AND/OR THE SMACNA MANUAL. CUTTING, PATCHING AND PAINTING: UNLESS OTHERWISE DIRECTED BY THE LANDLORD CRITERIA, THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING REQUIRED IN CONNECTION WITH HIS WORK. ALL FINISHED SURFACES THAT ARE CUT SHALL BE REPLACED IN KIND SO THAT THERE ARE NO VISIBLE EVIDENCE OF "PATCH". PAINTING OF MECHANICAL WORK SHALL BE BY PRIME CONTRACTOR. ALL EQUIPMENT WHICH HAS HAD THE FINISH DAMAGED BY INSTALLATION OR TRANSPORTATION SHALL BE REFINISHED. ROOF AND OTHER PENETRATIONS: EACH CONTRACTOR REQUIRING OPENINGS IN THE ROOF OF THE BUILDING STRUCTURE (WHERE REQUIRED) SHALL MAKE ARRANGEMENTS WITH THE LANDLORD FOR SUCH OPENINGS. PROCEDURE AND COST ARRANGEMENTS SHALL BE OUTLINED IN THE LANDLORD CRITERIA. COMPLY WITH ALL LANDLORD REQUIREMENTS. ALL ROOF PENETRATIONS SHALL BE ARRANGED TO PROVIDE A WEATHER -TIGHT INSTALLATION. THE INSTALLATION SHALL INCLUDE, WHERE REQUIRED, VENTILATING COLLARS TO GIVE PROPER CLEARANCE FROM COMBUSTIBLE ROOFS, FLOORS, CEILINGS OR OTHER SUCH STRUCTURES. FIRE -PROOFING SHALL BE PROVIDED USING MATERIALS CONFORMING WITH MUNICIPAL CODES AND ORDINANCES. DUCTWORK: A. ALL DUCTWORK SHALL BE INSTALLED AS SHOWN ON MECHANICAL DRAWINGS. B. THE DUCTWORK SHALL BE CLEAR INSIDE OF THE SIZES SHOWN ON THE DRAWINGS. ALL DUCTS TO BE SHEET METAL DUCTS AS PER ASHRAE AND SMACNA GUIDLINES. C. FLEXIBLE DUCTS SHALL BE LIMITED TO 5'-0" MAX. FOR CONNECTION TO AIR DEVICES. D. DUCTWORK SHALL BE "FACTORY MADE" CLASS 1 GALVANIZED SHEET METAL, MINIMUM 26 GAUGE WITH IRON SUPPORTS SECURED TO OVERHEAD MEMBERS AT 5'-0" ON CENTER. DUCTWORK MATERIALS SHALL BE PER SMACNA STANDARDS AND CURRENT MECHANICAL CODE. DUCTWORK INSULATION: SUPPLY FROM THE AIR CONDITIONING UNIT SHALL BE WRAPPED WITH A MIN. R -VALUE OF 8 FIBERGLASS, FOIL BACKED INSULATION TO PREVENT CONDENSATION. GRILLES AND DIFFUSERS: GRILLES AND DIFFUSERS SHALL BE AS MANUFACTURED BY KREUGER, HART AND COOLEY, BARBERCOLMAN, OR TITUS. EACH IS TO BE FITTED WITH A VOLUME DAMPER. (OPPOSED BLADE DAMPER) TESTING AND BALANCING CERTIFIED (AABC OR NABB) INDEPENDENT TESTING COMPANY TO TEST AND BALANCE SYSTEM TO CFM AS SPECIFIED. REPORT RESULTS TO TENANT AND ARCHITECT. GUARANTEE: A. EACH CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE IN WRITING ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE OF OWNER. THE CONTRACTOR SHALL PROVIDE FREE SERVICE FOR ALL EQUIPMENT INVOLVED IN HIS CONTRACT DURING THIS GUARANTEE PERIOD. B. THE GUARANTEE SHALL INCLUDE RESTORATION OF ITS ORIGINAL CONDITION OF ALL ADJACENT WORK THAT MUST BE DISTURBED IN FULFILLING THIS GUARANTEE. C. ALL SUCH REPAIRS AND/OR REPLACEMENTS SHALL BE MADE WITHOUT DELAY, AND AT THE CONVENIENCE OF THE OWNER. SUBSTITUTIONS: A. APPROVALS OF SUBSTITUTIONS FOR "APPROVED EQUAL", MUST BE IN WRITING AND SUBSTITUTION MUST BE APPROVED BEFORE INSTALLATION. INSTALLATION WITHOUT PRIOR APPROVAL MAY RESULT IN CONTRACTOR REMOVING SUBSTITUTION AND REPLACING IT WITH SPECIFIED ITEM AT HIS EXPENSE. B. APPROVAL MAY BE GIVEN BY ARCHITECT, ENGINEER OR OWNER. HVAC EQUIPMENT: (2) EXISTING GAS ROOF TOP UNITS ARE TO BE REUSED WITH MODIFICATIONS TO THE DUCTWORK LAYOUT AND DISTRIBUTION TO DIFFUSERS/GRILLES AS SHOWN ON SHEET M1. PROVIDE ONE NEW CEILING MOUNTED EXHAUST FAN WITH ALL ASSOCIATED EXHAUST DUCTWORK. SEE SHEET M1 FOR AIR BALANCING REQUIREMENTS AND ADDITIONAL REQUIREMENTS. SPACE TEMPERATURE CONTROL FOR EACH ROOF TOP UNIT. A. INSTALL THERMOSTATS ROOF TOP UNITS AS NOTED ON SHEET M1. SEQUENCE OF OPERATIONS (EXISTING ROOF TOP UNITS) A. EXISTING SEQUENCE OF CONTROLS (VERIFY IN FIELD). 1. OCCUPIED HOURS. A. UNIT OUTDOOR AIR DAMPER SHALL OPEN TO ITS MINIMUM POSITION AND UNIT SUPPLY FAN SHALL OPERATE CONTINUOUSLY. B. UNIT OUTDOOR AIR DAMPER SHALL MODULATE FROM ITS MINIMUM SCHEDULED POSITION TO ITS MAXIMUM SCHEDULED POSITION IN RESPONSE TO SPACE MOUNTED CO2 SENSOR (BY OTHERS) SET AT 1,000 PPM. C. UNIT COMPRESSOR(S) OR HEAT EXHANGER SHALL CYCLE STAGE TO MAINTAIN SPACE SETPOINT. D. UNIT ECONOMIZER CYCLE SHALL BE INITIATED UPON A SIGNAL FROM OUT DOOR AND RETURN AIR TEMPERATURE AND ENTHALPY SENSORS. OUTDOOR AIR DAMPER, RETURN AIR DAMPER, AND UNIT COMPRESSOR(S) SHALL CYCLE TO MAINTAIN SPACE SETPOINT. ECONOMIZER CYCLE SHALL OVER RIDE CO2 MONITORING SYSTEM. 2. UNOCCUPIED HOURS. A. UNIT OUTDOOR AIR DAMPER SHALL REMAIN CLOSED AND UNIT SUPPLY FAN SHALL CYCLE ON A SIGNAL FROM SPACE SENSOR. B. UNIT COMPRESSOR(S) SHALL CYCLE OR HEAT EXCHANGER SHALL STAGE WITH UNIT SUPPLY FAN TO MAINTAIN SPACE SETPOINT. 3. SMOKE ALARM (WHEN REQUIRED) A. UNIT OUTDOOR AIR DAMPER SHALL CLOSE AND UNIT SUPPLY FAN SHALL STOP ON A SIGNAL FROM DUCT SMOKE DETECTOR. DUCT SMOKE DETECTOR SHALL SEND A SIGNAL TO REMOTE ALARM DEVICE. PLUMBING SCOPE: A. THE WORK TO BE PERFORMED UNDER THE PLUMBING SPECIFICATIONS AND DRAWINGS CONSISTS OF FURNISHING ALL LABOR AND MATERIAL FOR THE COMPLETE INSTALLATION OF ALL PLUMBING SYSTEMS FOR TENANT SPACE. THE WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING: 1. COLD AND HOT WATER SYSTEMS 2: DRAINAGE AND VENT SYSTEMS 3. INSULATION GENERAL: A. THIS SPECIFICATIONS IS INCLUSIVE FOR EACH ITEM REQUIRING ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO PROPERLY INSTALL, ALTER, ADJUST, AND PUT INTO OPERATION, THE COMPLETE PLUMBING SYSTEM . B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER LAYOUT AND CONSTRUCTION OF THE WORK INCLUDED IN THIS CONTRACT. WORKMANSHIP: ALL WORK MUST BE DONE IN A WORKMANLIKE MANNER TO THE COMPLETE SATISFACTION OF THE ENGINEERS AND SHALL BE PERFORMED BY QUALIFIED MECHANICS. A. ALL MATERIALS AND EQUIPMENT SHALL BE. NEW, AND SHALL CONFORM TO THE GRADE, QUALITY AND STANDARDS SPECIFIED HEREIN. ALL MATERIALS AND EQUIPMENT UTILIZED SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA. B. ALL EQUIPMENT OFFERED UNDER THESE SPECIFICATIONS SHALL BE LIMITED TO PRODUCTS REGULARLY PRODUCED AND RECOMMENDED FOR SERVICE, IN ACCORDANCE WITH ENGINEERING DATA, RATINGS, OR OTHER COMPREHENSIVE LITERATURE MADE AVAILABLE TO THE PUBLIC AND IN EFFECT AT THE TIME OF OPENING OF BIDS. C. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR TYPE AND CAPACITY OF EACH PIECE OF EQUIPMENT USED. LAW, ORDINANCES AND REGULATIONS: A. ALL MECHANICAL SYSTEMS IN ALL AND/OR PART SHALL CONFORM TO ALL PERTINENT LAWS, ORDINANCES AND REGULATIONS AND ALL BODIES HAVING JURISDICTION, AT ALL GOVERNING LEVELS, NOTWITHSTANDING IN THESE PLANS AND SPECIFICATION TO THE CONTRARY. IN CASE OF CONFLICT BETWEEN GOVERNING LEVELS, THE MORE STRINGENT LAWS SHALL APPLY. B. CONTRACTOR SHALL PAY ALL FEES AND OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY ANY AUTHORITY HAVING JURISDICTION IN CONNECTION WITH HIS WORK. C. WHERE APPLICABLE, ALL MATERIAL SHALL BEAR THE THE NATIONAL BOARD OF FIRE UNDERWRITER'S SEAL OF APPROVAL. CERTIFICATES TO THIS EFFECT TO BE FURNISHED TO ARCHITECT TO BE TO ARCHITECT UPON REQUEST. ESCUTCHEONS: A. ALL EXPOSED PIPES, EXCEPT AS OTHERWISE DESCRIBED, PASSING THRU WALLS, FLOORS, CEILINGS, ETC. IN FINISHED SPACES, SHALL BE PROVIDED WITH SOLID PATTERN HEAVY CEILING, FLOOR OR WALL ESCUTCHEONS WITH SET SCREW. ESCUTCHEONS AND PLATES SHALL BE OF STEEL OR MALLEABLE IRON WITH PRIME COAT READY FOR PAINTING. ESCUTCHEONS WILL NOT BE PROVIDED WHERE SLEEVES INTENTIONALLY EXTEND ABOVE FINISHED FLOOR. B. ALL EXPOSED PLUMBING SHORT BRANCH CONNECTIONS TO FIXTURES AND/OR EQUIPMENT PASSING THROUGH WALL OR FLOORS SHALL BE EQUIPPED WITH PRESS BRASS, CHROMIUM PLATED, SOLID TYPE ESCUTCHEONS. GUARANTEE: A. EACH CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE IN WRITING ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY OWNER. THE CONTRACTOR SHALL PROVIDE FREE SERVICE FOR ALL EQUIPMENT INVOLVED IN HIS CONTRACT DURING THIS GUARANTEE PERIOD. B. THE GUARANTEE SHALL INCLUDE RESTORATION TO ITS ORIGINAL CONDITION OF ALL ADJACENT WORK THAT MUST BE DISTURBED IN FULFILLING THIS GUARANTEE. C. ALL SUCH REPAIRS AND/OR REPLACEMENTS SHALL BE MADE WITHOUT DELAY, AND AT THE CONVENIENCE OF THE OWNER. TEMPORARY SERVICES: A. THE CONTRACTOR, AT HIS OWN EXPENSE AND COST, SHALL INSTALL, OPERATE, PROTECT AND MAINTAIN THE RESPECTIVE TEMPORARY SERVICES AS REQUIRED BY HIS WORK. TEST OF PIPING AND SYSTEM: A. THE SYSTEMS OF PIPING AS INSTALLED BY THIS CONTRACTOR MUST BE TESTED WITH WATER OR AIR AND PROVEN TIGHT TO THE SATISFACTION OF REPRESENTATIVES OF THE OWNER. TESTING INSTRUMENTS MUST BE FURNISHED BY THE PLUMBING CONTRACTOR. B. TEST MUST BE MADE WITH WATER, EXCEPT WHEN THERE IS DANGER FROM FREEZING, THEN TESTS MAY BE MADE WITH AIR. WOODEN PLUGS ARE NOT TO BE USED IN MAKING TESTS. STERILIZATION OF DOMESTIC WATER SYSTEM: A. BEFORE BEING PLACED IN SERVICE ALL WATER LINES SHALL BE CHLORINATED TO THE SATISFACTION OF THE A.W.W.A SPECIFICATIONS C601 -53T. SOIL WASTE AND VENT PIPING: PIPING MATERIALS A. SOIL WASTE PIPING SHALL BE SERVICE WEIGHT CAST IRON PIPE, BELL & SPIGOT TYPE AS REQUIRED. B. VENT PIPE SHALL BE SERVICE WEIGHT CAST IRON BELL & SPIGOT TYPE AS REQUIRED PER LOCAL CODE. NOTE: ABS WASTE & VENT PIPING MAY BE UTILIZED IF APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION. ABS PIPING SHALL NOT BE INSTALLED IN A RETURN AIR PLENUM ABOVE THE CEILING.. INSULATE -ALL LINES (ABOVE CEILING/IN WALLS INCLUDED): A. DOMESTIC HOT WATER PIPING LESS THAN 1-1/2" IN DIAMETER SHALL BE INSULATED WITH 1" THICK INSULATION WITH CONDUCTIVITY "K" FACTOR OF 0.21-0.28 AT 100F MEAN RATING TEMPERATURE PER IECC TABLE C403.2.10. DOMESTIC COLD WATER PIPING LESS THAN 1-1/2" IN DIAMETER SHALL BE INSULATED WITH 1/2" THICK INSULATION WITH CONDUCTIVITY "K" FACTOR OF 0.21-0.27 AT 75F MEAN RATING TEMPERATURE PER IECC TABLE C403.2.10. SUBSTITUTIONS: A. SUBSTITUTIONS WILL BE CONSIDERED FOR "OR EQUAL" BUT MUST BE APPROVED IN WRITING, BY OWNER, ARCHITECT OR ENGINEER, PRIOR TO INSTALLATION. B. IF, AFTER PLANS ARE COMPLETED, AUTHORITIES RULE THAT HANDICAPPED RESTROOM IS REQUIRED, BUT NOT SHOWN, USE AMERICAN STANDARD 'CADET -HI" WATER CLOSETS AND SET LAVATORY AT PROPER HEIGHT WITH LEVER HANDLES. (VERIFY ALL FINAL EQUIPMENT SPECS WITH PLUMBING DRAWING). WATER PIPING: A. WATER PIPING UNDER FLOOR SHALL BE TYPE "K" SOFT COPPER WITH SILVER SOLDER JOINTS.. B. WATER PIPING ABOVE FLOOR SHALL BE TYPE "L" HARD DRAWN COPPER WITH LEAD FREE SOLDER JOINTS. FIRE PROTECTION EXECUTION -INSTALLATION: B. A. GENERAL CONTRACTOR TO VERIFY MALL SPRINKLER CONTRACTOR REQUIREMENTS AND USE SPECIFIED CONTRACTOR IF REQUIRED. INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 13. INSTALL SPRINKLER PIPING PRODUCTS WHERE REQUIRED IN ACCORDANCE WITH RECOGNIZED PRACTICES TO ENSURE THAT FIRE PROTECTION SPRINKLER PIPING COMPLIES WITH GOVERNING REQUIREMENTS AND SERVES THE INTENDED PURPOSES. C. EXAMINE OTHER WORK SHOWN ON THE DRAWINGS AND CONDITIONS AT THE JOB SITE. COORDINATE THE ROUTING OF WORK WITH OTHER TRADES TO AVOID INTERFERENCE WITH OTHER INSTALLATIONS. D. PIPE ROUTING AND SPRINKLER HEAD LOCATIONS SHALL BE LOCATED AS REQUIRED TO AVOID EQUIPMENT, PLUMBING, HEATING AND AIR CONDITIONING PIPING, DUCTWORK, LIGHTING FIXTURES, ELECTRICAL CONDUITS AND BUS DUCTS AND SIMILAR WORK. E. PROVIDE PIPE OFFSETS AS REQUIRED TO COMPLETE THE INSTALLATION. MODIFY PIPE, PREFABRICATED PIPING, PIPE HANGERS AND OTHER COMPONENTS AS REQUIRED TO FIT THE JOB SITE CONDITIONS. CLEANING AND FLUSHING: PRIOR TO CONNECTING SPRINKLER PIPING FOR FLUSHING, FLUSH WATER FEED MAINS, LEAD-IN CONNECTIONS AND CONTROL PORTIONS OF SPRINKLER PIPING. AFTER FIRE SPRINKLER PIPING INSTALLATION HAS BEEN COMPLETED AND BEFORE PIPING IS PLACED IN SERVICE, FLUSH ENTIRE SPRINKLER SYSTEM UNDER PRESSURE, AS REQUIRED TO REMOVE FOREIGN SUBSTANCES AS REQUIRED BY NFPA 13. CONTINUE FLUSHING UNTIL WATER IS CLEAR AND CHECK TO ENSURE THAT DEBRIS HAS NOT CLOGGED SPRINKLERS. TESTING: A. AFTER FLUSHING SYSTEM, TEST FIRE SPRINKLER PIPING HYDROSTATIC ALLY IN ACCORDANCE WITH NFPA 13, AT NOT LESS THAN 200 PSI OR AT 50 PSIG. CHECK SYSTEM FOR LEAKAGE AT JOINTS. MEASURE HYDROSTATIC PRESSURE AT LOW POINT OF EACH SYSTEM OR ZONE BEING TESTED. B. REPAIR OR REPLACE PIPING SYSTEM AS REQUIRED TO ELIMINATE LEAKAGE IN ACCORDANCE WITH NFPA STANDARDS FOR "LITTLE OR NO LEAKAGE" AND RETEST AS SPECIFIED TO DEMONSTRATE COMPLIANCE. SPRINKLER MAINS AND BRANCHES PIPING MATERIAL: BLACK STEEL, SCHEDULE 40 OR LIGHTWEIGHT SPRINKLER PIPE, SCHEDULE 10 ASTM A 135 (IF ALLOWED BY LANDLORD AND LOCAL AUTHORITIES). FITTINGS: THREADED, CLASS 175. MECHANICAL COUPLINGS AND TEES OF A ROLLED GROOVED TYPE WILL BE ACCEPTED (IN LIEU OF THREADED) IF BOTH U.L. LISTED AND FIRE MARSHAL APPROVED. INSTALLATION: ALL SPRINKLER PIPING SHALL BE CONCEALED UNLESS OTHERWISE INDICATED. ALL PIPING SHALL BE LOCATED TO AVOID INTERFERENCE WITH ALL OTHER ELEMENTS ABOVE CEILINGS, ETC. SUPPORT ALL HORIZONTAL PIPING AT NOT GREATER THAN 10 FEET INTERVALS, EXCEPT PIPES OF SIZE 1-1/2" AND LARGER WHICH SHALL BE SUPPORTED AT NOT GREATER THAN FIFTEEN FEET INTERVALS, WITH APPROVED SWIVEL SPLIT RING HANGERS WITH ROD SUPPORTS AND SWAY BRACES AT EVERY THIRD HANGER. ALL SPRINKLER PIPING SHALL BE INSTALLED SO THAT IS CAN BE THOROUGHLY DRAINED AND WHERE PRACTICAL, ARRANGE TO DRAIN THE MAIN VALVE. SPRINKLER HEADS A. SPRINKLER HEADS IN AREAS WITH LAY -IN AND DRYWALL CEILINGS SHALL BE CENTERED IN LAY -IN CEILING TILE WITH WHITE CONCEALED HEADS, 165 DEGREE RATED. B. ALL SPRINKLER HEADS SHALL BE 1/2" ORIFICE, RATED AT 165 DEGREES WITH A K -FACTOR OF 5.65. C. ALL SPRINKLER HEADS SHALL BE INSTALLED IN ACCORDANCE TO NFPA 13 AND ALL LOCAL CODES AND AUTHORITIES HAVING JURISDICTION. PRIOR . TO BID, THE CONTRACTOR SHALL REVIEW THE MECHANICAL, ELECTRICAL AND KITCHEN EQUIPMENT DRAWINGS. THE CONTRACTOR SHALL INCLUDE IN HIS BID ALL RELEVANT WORK IN THE ENTIRE SET OF DOCUMENTS AND REPORT ALL DISCREPANCIES BETWEEN THESE DRAWINGS TO THE ENGINEER PRIOR TO BIDDING FOR CLARIFICATION. IF DISCREPANCIES REMAIN UNRESOLVED DUE TO A SHORT TIME FRAME, THE CONTRACTOR SHALL INCLUDE THE MOST WORK AND THE HIGHER COSTS IN THE BID. SOLUTIONS TO UNREPORTED DISCREPANCIES WILL BE DETERMINED BY THE ARCHITECT/ENGINEER, WITH NO ADDITIONAL COMPENSATION DUE TO THE CONTRACTOR. DRAWINGS AND SPECIFICATIONS ARE TO BE CONSIDERED AS SUPPLEMENTING EACH OTHER. WORK SPECIFIED BUT NOT SHOWN ON DRAWINGS, OR SHOWN ON DRAWINGS BUT NOT SPECIFIED, SHALL BE PERFORMED OR FURNISHED AS THOUGH MENTIONED IN BOTH SPECIFICATIONS AND DRAWINGS. IF NOT OTHERWISE DIRECTED, INSTALLATION OF ALL SYSTEMS AND EQUIPMENT SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. WHERE WORK DESCRIBED IN THE SPECIFICATIONS IS IN CONFLICT WITH THE WORK SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL SUPPLY THE GREATER QUANTITY, QUALITY AND COST VIA THE BID AND CONTACT THE ENGINEER FOR CLARIFICATION ON DIRECTION PRIOR TO INSTALLATION. fr'tF7 012)1 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 18 2017 City of Tukwila BUILDING DIVISION DUNHAM EI Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHME 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering PROJECT NO. 0418743-004 MBA Architects, Inc. 3823 Creekside Lane Holmen, WI. 54636 608-785-2760 FAX: 608-785-2750 E—mail: officeOmba—architects.com CLIENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 SEE'S CANDIES 3423 S LA. CIENEGA BLVD. LOS ANGELES, CA 90016 PH: 310/287-4616 FAX: 310/842-4436 SECS CONTACT RICHARD ESCALANTE 310/ 287-4616 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785-2760 date c 0 0 -o 0 v c 0 a L .2 0 E c 0 0 0 .0 c > comments VIEW 08/16/17 0 BID/ PERMIT 8/28/17 0 0 0 0 0 drown by: DS checked by: GS THIS SHEET CONTAINS; MECHANICAL AND PLUMBING SPECIFICATIONS RECEIVED CITY OF TUKWILA SEP 1 1 2017 PERMIT CENTER MP1 ARCHITECT'S COMMISSION NUMBER 17-725i 61