HomeMy WebLinkAboutPermit M17-0135 - BOEING - YARD GATE 8 SPLIT UNITBOEING -YARD GATE 8 9725 E MARGINAL WAY S M17-0135 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 5624201036 Permit Number: 9725 E MARGINAL WAY S Project Name: BOEING - YARD GATE 8 Issue Date: Permit Expires On: M 17-0135 9/28/2017 3/27/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 CONNIE HARDIN 4600 S 134 PL, SEATTLE, WA, 98168 HOLADAY PARKS INC 4600 S 134 PL , SEATTLE, WA, 98168 HOLADPI379NO Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2019 DESCRIPTION OF WORK: INSTALL (1) SPLIT UNIT AND ASSOCATED REFER PIPING Valuation of Work: $5,000.00 Type of Work: NEW Fuel type: Fees Collected: $272.04 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature:MI 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Date: 41 i 2 1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or loc . ►: s :ul.ti.ng consruction or the performance of work. I am authorized to sign and obtain is developme pemit a ar: _ t.'the condition .. cached to this permit. Signature: Print Name: Date: (. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: Readily accessible access to roof mounted equipment is required. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL yGiz7 • CITY OF TUKWIL Community Development Department Permit Center 6300 SouthcenterBlvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Sg Mechanical Permit No. Mn --O(2 "9 Project No. Date Application Accepted: ' Date Application Expires: 'I/ (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address"\ ? a_ or) L4 TenantName: `Q King Co Assessor's Tax N4 (12314006 PROPERTY OWNER Name!Z_ Address City: 370 Nt State: '1 Zip' zti CONTACT PERSON — person receiving all project communication Name: 1WrdtrL p Address4oO , 3 ll-�V,V7C . Ci 4 Stat[["'' ZiE!}1ff4 Pho t'iS 0 F oo Z ito II+�7.z G�CIY� 2� Emayli h t:t k 0. Vth le. Ctc,... Suite Number: Floor: New Tenant: ❑ Yes K..No MECHANICAL CONTRACTOR INFORMATION Company Name:l'1 V�aL,4-1.-Arles () Address .Obs P.J C Jt :e State: 13 ZiP7 pQ r, Phone] r6 Z. L Fax 2 ,{ t. 60 Contr Reg N40 3' 1 Exp Date: 00 17 Tukwila Business License No..: (oh Q c�. ,7 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Use: Residential: New Commercial: New Fuel Type: Electric ❑ Replacement Replacement Gas 0 1,14t44 A -C\ Other: H:Wpplications\Forms-Applications On Linc'2016 Applications\Mcchanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 1 <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfin Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 1 Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) t\rt 1 Boiler/Compressor Qty 0-3 hp/1 00,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-1 Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: I lit 0 t e - CLrC1 to Day Telephone._v6( 2 5-0 ■ L{ 5" 3v Address: 4600 S 1.304' per( _ l.Q _. ; a0 &g Date: State H:4Applications\Forms-Applications On LineVA16 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 PermitTRAK ACCOUNT QUANTITY PAID $272.04 M17-0135 Address: 9725 E MARGINAL WAY S Apn: 5624201036 $272.04 Credit Card Fee $7.92 Credit Card Fee R000.369.908.00.00 0.00 $7.92 MECHANICAL $253.96 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $170.02 PLAN CHECK FEE R000.322.102.00.00 0.00 $50.79 TECHNOLOGY FEE $10.16 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12375 R000.322.900.04.00 0.00 $10.16 $272.04 Date Paid: Wednesday, September 20, 2017 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 02274G Printed: Wednesday, September 20, 2017 3:55 1 of 1 PM CRSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit /.1117 -0135 - PERMIT 17.01.7g PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: y� %lY6 d� /�/ U f 6 Type of Inspection: meC%i fil-. 9-iN4L. -• Address: 9725 .6". /740/ ii q ij', Y s'® Date Called: C)l<- Special Instructions: • R, la 6 i-- J I Date Wanted: .2-9-113 (m: P.011 Requester: N 77/4 P• hone .2-07-9Y8- 473o4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: — kni EC/401011- 21\bei-4 e5K a �. NM IC4- 1)( P IT— r1-"fise; C)l<- r4C N4N',ckt_ R, la 6 i-- J I Inspector: Date: 2...44e REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2/1/2018 City of Tukwila Department of Community Development CONNIE HARDIN 4600 S 134 PL SEATTLE, WA 98168 RE: Permit No. M17-0135 BOEING - YARD GATE 8 9725 E MARGINAL WAY S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/27/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/27/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, achel e P le P Y Permit Technician File No: M17-0135 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0135 DATE: 09/25/17 PROJECT NAME: YARD GATE 8 SITE ADDRESS: 9725 E MARGINAL WAY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS AT A1)c 611`11 `11 Building Division Public Works ❑ OA OR' Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 09/26/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) 10/24/17 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC 1-Inme. Espaiiol Contact Safety & Health Claims & Insurance Clik Washington State Department of 4 Labor & Industries Page 1 of 3 Search L&I A-7, index Help - My L&I Workplace Rights Trades & Licensing HOLADAY PARKS INC Owner or tradesperson BECK, DAVID CARL Principals BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUIT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) 4600 S 134TH PL SEATTLE, WA 98168 206-248-9700 KING County WA UBI No. Business type 578 004 089 Corporation Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 9/28/2017 VICINITY MAP ❑ n 14-01 7-127 KING COUNTY AIRPORT OFFICE CENTER (FM) FROM DOWNTOWN SEATTLE 900 99 EXIT 158 d PROJECT SITE EXIT 157 EXIT 157 EAST MARGINAL WAY CORPORATE PARK 99 599 TUKWILA FROM KENT & AUBURN DEVELOPMENTAL CENTER NO SCALE 900 SYM REVISION REOPEN GATE J8 W4618793 BY CEI APPROVED DATE SYM REOPEN GATE J8 W4618793 BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA MAP OXBOW PARKING LOT PROJECT LOCATION NO SCALE REVISION BY APPROVED DATE AH 07.12.17 CODE SUMMARY TYPE OF APPLICATION: ❑ NEW ALTERATION ❑ ADDITION ❑ DEMOLITION BRIEF PROJECT NARRATIVE: REOPENING GATE J8 INVOLVES THE REMOVAL OF CHAIN LINK FENCING, CONCRETE CURBING, ASPHALT AREAS AND THE EXISTING SWING GATES. NEW WORK INCLUDES RE—ALIGNING OF ROADWAY, PAVEMENT MARKINGS, SITE LIGHTING, NEW FENCING, BOLLARD PROTECTION, A NEW MANUAL GATE AND RE—CONDITION AN EXISTING GUARDHOUSE WITH POWER, HEATING/COOLING AND DATA. PARCEL NUMBER: TOTAL PARCEL AREA: TOTAL PROJECT AREA: AREA OF SOIL DISTURBANCE: ASPHALT MILL AND OVERLAY: REMOVED IMPERVIOUS SURFACE: (REPLACED WITH LAWN) ESTIMATED EARTHWORK QUANTITIES: LAND USE CODE GEOTECHNICAL REPORT BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS BUILDING ROOF OCCUPANT LOAD BUILDING HEIGHT STORIES HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE CONTRACTOR & STATE NUMBER: BOEING CONSTRUCTION MANAGER: BOEING PERMIT COORDINATOR: 0003400026 169,013 SF (3.88 AC) PER KINC CO. PARCEL DATA APPROXIMATELY 7,100 SF (0.16 AC) APPROXIMATELY 1,946 SF (0.05 AC) APPROXIMATELY 1,502 SF (0.03 AC) APPROXIMATELY 0 SF (0 AC) CUT FILL TOTAL 50 CY 45 CY 5 CY (5 CY NET CUT) M-2 HEAVY INDUSTRY (CITY OF TUKWILA) N/A 2015 IBC, IFC, U.P.C., AND THE WAC 51-20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUP B V—B 36 SQ. FT. 36 SQ. FT. 105 SQ. FT. 1 OCCUPANT 8'-4" 1 BARRIER FREE N/A CATEGORY 'D' THE BOEING CO. BOEING* 294ML (01-18-2019) GABRIEL HESS JOHN MURDOCH E—MAIL: john.s.murdoch®boeinq.com PHONE: 206-316-7870 PHONE: 253-740-0214 ffaNG° C'— OFFMAN N G I N E E R S 1601 Fifth Avenue, Suite 900 1 Seattle, WA 98101 ph 206.623.07171 fax 206.624.3775 coffman.com LASTING creativity 1 results 1 relationships ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CEI DATE 07.12.17 CHECKED A. HAZEN 07.12.17 it o NU1 -0[35 SEPARATE PERMIT REQUIRED FOR: 0 Mechanical (trE`tectrical Wiumbing C$4s Piping City of Tukwila BLIII_ ?ING DIVISION Cityof BUILDING DIVISION CODES AND PERMITS PROJECT TITLE: REOPEN GATE J8 QUANTITY SUBMITTED: ❑ 5 SETS: GENERAL PERMIT (SHELL & CORE) OR STRUCTURAL TENANT • 4 SETS: TENANT IMPROVEMENT (NON—STRUCTURAL) ❑ 3 SETS: FIRE PROTECTION/SPRINKLERS ❑ 2 SETS: TENANT IMPROVEMENT (REVISION) SUBMITTED FOR PERMIT & REVIEW: ❑ BUILDING GRADING ❑ PLUMBING ❑ LANDSCAPE MECHANICAL ❑ DEMOLITION ❑ STRUCTURAL ❑ — GA ❑ TO BE REVIEWED UNDER SEPARATE PERMIT JOB NUMBER: W4618793 IMPROVEMENT ra ELECTRICAL ❑ FIRE PROTECTION ❑ CANTILEVER RACKS ❑ - GO WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE—APPROACHES COMPLIANCE OPTION ❑ PRESCRIPTIVE ❑ LPA ❑ ANALYSIS M N/A SPECIAL INSPECTIONS REQUIRED: ❑ WELD ❑ CONCRETE ❑ REBAR ❑ ANCHOR BOLTS El STRUCTURAL BOLTING N/A El STRUCTURAL OBSERVATION ❑ OTHER CALCULATIONS TYPE. N/A ATTACHED (YES) (NO) 1 GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO JOHN MURDOCH AT BLDG. 9-51.2 COL M/2, AFTER COMPLETION OF THIS CONSTRUCTION. REVISIONS No changes shall be made to the scot* of work without prior approval of ;jk'vila Building Division. NOTE: i 3`'t'isioris will require a new plan submittal and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 $ 20I7 City of Tukwila BUILDING DIVISION 07.12.2017 ISSUE FOR CONSTRUCTION SUBTITLE COVER SHEET RECEIVED CITY OF TUKWILA SEP 2 0 2017 PERMIT CENTER CURRENT REVISION SYMBOL W4618793 DATE 07.12.17 ENGINEER CHECKED APPROVED APPROVED TITLE GENERAL MASTER REOPEN GATE J8 09-YRD COL. DEV. CENTER, WA SHEET GO JOB NO. W4618793 COMP NO. DWG NO. 09—YRD—G 0 nG MR /17 V HC A\CAL VAC LI -GI -\D GENERAL SYMBOL DESCRIPTION IL 24/12 24/12 RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN 24/12 DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST h 240 9 240 f ROUND DUCT, NUMBER INDICATES DIAMETER () 24/120 f 24/120 f OVAL DUCT, FIRST NUMBER INDICATES MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER x SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING TOWARDS SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING AWAY EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING TOWARDS EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING AWAY EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING TOWARDS L--"1 EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING AWAY t==:111 TRANSITION RECTANGULAR TO RECTANGULAR TRANSITION AT TAKE OFF TRANSITION SQUARE OR RECTANGULAR TO ROUND OR OVAL UP DOWN DUCT OFFSET UP OR DOWN OPPOSED BLADE DAMPER i PARALLEL BLADE DAMPER VOLUME DAMPER DUCT DAMPER, MOTOR OPERATED (ELECTRIC OR PNEUMATIC) t BDD BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) AD OR AP IL ACCESS DOOR (AD) OR ACCESS PANEL (AP) r FD FD f FIRE DAMPER (1 HOUR) FD2 ;FD2 f FIRE DAMPER (2 HOUR) SYM REVISION BY GENERAL SYMBOL DESCRIPTION THERMOSTAT, REMOTE, CEILING WITHTANGULAR TURNING VANESDUCTSQUARE ELBOW �� Q '1,, MARK NUMBER HUMIDISTAT CEILING H 4D DUCT TYPE SMOKE DETECTOR clD DUCT TYPE HEAT DETECTOR 2 STATIC PRESSURE REGULATOR RECTANGULAR DUCT, RADIUS VANED ELBOW TEMPERATURE SENSOR, HUMIDITY SENSOR, DUCT MOUNTED am I\ Q THERMOSTAT, WALL ON NIGHT THERMOSTAT THERMOSTAT, CEILING T EXTRACTION GRID TT FLEXIBLE DUCT I-14 - —*1 -----0" FLEXIBLE DUCT CONNECTION SIDEWALL SUPPLY AIR DIFFUSER, GRILLE OR REGISTER AND CFM AIR FLOW 10000 CFM SIDEWALL RETURN/EXHAUST AIR GRILLE OR REGISTER AND AIR FLOW ®__A,_ 100 CFM SCREENED OPENING AND CFM AIR FLOW IL 1100 -- SUPPLY OUTLET, CEILING TYPE, DIFFUSER OR GRILLE, SQUARE OR RECTANGULAR AND CFM AIR FLOW (SEE NOTE 3) ---- __ SUPPLY OUTLET, CEILING TYPE, ROUND AND CFM AIR FLOW (SEE NOTE 3) LINEAR DIFFUSER AND CFM AIR FLOW (SEE NOTE 3) RETURN/EXHAUST REGISTER OR GRILLE, CEILING DUCT TYPE AND CFM AIR FLOW .f I-71 IBJ Z.'s-iv-- RETURN/RELIEF GRILLE, CEILING TYPE, NON -DUCTED — — , --- \ UNIT HEATER, HORIZONTAL UNIT HEATER, VERTICAL PROJECTION LINED DUCT fill SOUND ATTENUATOR LINED DUCT WITH ACCESS DOOR AND SMOKE DAMPER p AD SD LINED DUCT WITH AXIAL FLOW FAN G] CENTRIFUGAL FAN CENTRIFUGAL FAN, INLET GUIDE VANES C,C IFS EXHAUST FAN ._ SUPPLY AIR FLOW DIRECTION -4' RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION APPROVED DATE SYM REVISION GENERAL SYMBOL DESCRIPTION THERMOSTAT, REMOTE, CEILING R �� Q HUMIDISTAT, WALL MARK NUMBER HUMIDISTAT CEILING H 4D DUCT TYPE SMOKE DETECTOR clD DUCT TYPE HEAT DETECTOR 2 STATIC PRESSURE REGULATOR T H TEMPERATURE SENSOR, HUMIDITY SENSOR, DUCT MOUNTED am Q THERMOSTAT, WALL ON NIGHT THERMOSTAT THERMOSTAT, CEILING T TEMPERATURE TRANSMITTER TT VAV BOX LEGEND 1ST CHARACTER: V= VARIABLE AIR TERMINAL UNIT VOLUME' 2ND CHARACTER: F= FAN POWERED UNIT C= SHUTOFF UNIT 3RD CHARACTER: E= ELECTRIC HEAT W= HOT WATER HEAT C= NO HEAT COIL �� MARK NUMBER BY APPROVED DATE REOPEN GATE J8 W4618793 CEI TB 07.12.17 SUGGESTED ABBREVIATIONS ABBREVIATION DESCRIPTION A MV AD ADD AF AFF AP APPROX ARCH AUD AVG BI BDD BFP BHD BHP BLDG BOD BOP BOS BTU BTU H BW C Cv sC CAP CC CCW CFM CI COND CONN CONT CPLG CPVC CW DA DB DBD DIA 0 DIS DIR DN DS DWG dB EA EAT EFF ELL ELEC ELEV, EL ESP EVAP EWT EXH EXIST EXT FC FD FLR FCO FOB FOF FOIC FOT FPM FRP FS FT FV GAL GPM GALV GA HC HD HORIZ HP HPC HR HVAC HPU HTG ID IE IGV INSUL IN ANCHOR AUTOMATIC AIR VENT ACCESS DOOR ANGULAR DOWN DISCHARGE AIR FOIL WHEEL ABOVE FINISHED FLOOR ACCESS PANEL APPROXIMATELY ARCHITECTURAL ANGULAR UP DISCHARGE AVERAGE BACKWARD INCLINED WHEEL BACK DRAFT DAMPER BACKFLOW PREVENTER BOTTOM HORIZONTAL DISCHARGE BRAKE HORSE POWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUTTWELD • COMMON FLOW COEFFICIENT TEMPERATURE - DEGREES CELSIUS CAPACITY COOLING COIL COUNTER CLOCKWISE ROTATION CUBIC FEET PER MINUTE CAST IRON CENTER LINE CONDENSATE CONNECTION CONTINUED/CONTINUATION COUPLING CHLORINATED POLYVINYL CHLORIDE CLOCKWISE ROTATION DIRECT ACTING DRY BULB TEMPERATURE DOWN BLAST DISCHARGE DIAMETER DEIONIZED WATER SUPPLY DEIONIZED WATER RETURN DOWN DOWNSPOUT DRAWING DECIBELS EXHAUST AIR / EACH ENTER AIR TEMPERATURE (T) EFFICIENCY ELBOW ELECTRICAL ELEVATION EXTERNAL STATIC PRESSURE EVAPORATOR ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR / EXTERNAL TEMPERATURE - DEGREES FAHRENHEIT FORWARD CURVE WHEEL FIRE DAMPER FLOOR FLOOR CLEAN OUT FLAT ON BOTTOM FACE OF FLANGE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE GLASS FIBER REINFORCED PLASTIC FLOW SWITCH FEET FACE VELOCITY FPM GALLONS GALLONS PER MINUTE GALVANIZED GAGE, GAUGE HEATING COIL HEAD - FEET OF WATER HORIZONTAL HORSEPOWER HIGH PRESSURE CONDENSATE HOUR HEATING, VENTILATING AND AIR CONDITIONING HEAT PUMP UNIT HEATING INSIDE DIAMETER INVERT ELEVATION INLET GUIDE VANE INSULATION INCHES 7/11 /17 SUGGESTED ABBREVIATIONS ABBREVIATION DESCRIPTION KW KVA LAT LBS, LWT MA MAX MBH MCC MECH MIN MOV MTD, MTG NC NIC NO NTS NPSH OA OBD OF OS&Y OD OVHD PBD PD/AP PDI POC POS PRESS PRV PS PSIG PSV PVC RA RECT REF REV RH RM ROT RPM RQD RTN RV SA SCFH SCFM SHC SHF SHT SO SOV SP SQ SS STL STRUC SW SUCT TDH TEMP TH THC THD THRD TOD TOS TOP TP TS TSP TV TYP UBD VAV VD VP VERT VTA VTR WB WCO WG WHA W/ KILOWATT KILOVOLT -AMPERE LEAVING AIR TEMPERATURE (°F) POUNDS LEAVING WATER TEMPERATURE (°F) MIXED AIR MAXIMUM HEAT CAPACITY BTU PER HOUR X 1000 MOTOR CONTROL CENTER MECHANICAL MINIMUM MOTOR OPERATED VALVE MOUNTED, MOUNTING NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN / NUMBER NOT TO SCALE NET POSITIVE SUCTION HEAD OUTSIDE AIR OPPOSED BLADE DAMPER OVERFLOW OUTSIDE SCREW AND YOKE OUTSIDE DIAMETER OVERHEAD PARALLEL BLADE DAMPER PRESSURE DROP OR DIFFERENTIAL PRESSURE PLBG. & DRAINAGE INSTITUTE POINT OF CONNECTION POSITION PRESSURE PRSSURE REGULATING VALVE PRESSURE SWITCH PRESSURE - POUNDS PER SQUARE INCH, GAUGE PRESSURE RELIEF (SAFETY) VALVE POLYVINYL CHLORIDE REVERSE ACTING (CONTROLLER) / RETURN AIR RECTANGULAR REFERENCE REVISED RELATIVE HUMIDITY ROOM ROTATION REVOLUTIONS PER MINUTE REQUIRED RETURN ROOF VENT SUPPLY AIR STANDARD CUBIC FEET/HR STANDARD CUBIC FEET/MIN SENSIBLE HEAT CAPACITY SENSIBLE HEAT FACTOR SHEET SCREENED OPENING SOLENOID OPERATED VALVE STATIC PRESSURE SQUARE STAINLESS STEEL STEEL STRUCTURAL SOCKET WELD SUCTION TOTAL DYNAMIC HEAD (FEET OF WATER) TEMPERATURE TOTAL HEAD (FEET OF WATER) TOTAL HEAT CAPICITY TOP HORIZONTAL DISCHARGE THREADED TOP OF DUCT TOP OF STEEL TOP OF PIPE TOTAL PRESSURE TEMPERATURE SWITCH TOTAL STATIC PRESSURE TURNING VANE TYPICAL UP BLAST DISCHARGE VARIABLE AIR VOLUME VOLUME DAMPER VELOCITY PRESSURE VERTICAL VENT TO ATMOSPHERE VENT THROUGH ROOF WET BULB TEMPERATURE WALL CLEAN OUT WATER GAUGE (INCHES OF WATER) WATER HAMMER ARRESTOR WITH ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN CEI DATE 05.02.17 CF ECKED TB - 05.02.17 SUBTITLE HVAC LEGEND 17 013 ACOFFMAN NGINEERS 1601 Fifth Avenue, Suite 900 1 Seattle, WA 98101 ph 206.623.07171 fax 206.624.3775 coffman.com LASTING creativity 1 results 1 relationships REVIEWED FOR CODE COMPLIANCE APPROVED • SEP 28 2017 City of Tukwila BUILDING ICON RECEIVED CITY OF TUKWILA SEP 2 0 2017 PERMIT CENTER 07.12.2017 ISSUE FOR CONSTRUCTION CURRENT REVISION SYMBOL W4618793 DATE 07.12.17 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER REOPEN GATE J8 BUILDING 09-056 COL. X-X/X-X DEV, CENTER, WA SHEET MIA JOB NO. W4618793 COMP NO. DWG NO. 09-056-M1A 7/11 /17 '1 VHC A\CAL \G LHCH\D GENERAL PIPE IDENTIFICATION PIPE IDENTIFICATION PIPE FITTINGS PIPING SPECIALTIES WELDING SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION BREAK IN PIPE A COMPRESSED AIR, PLANT PCW— PROCESS COLD WATER —Z Z— Q TEST PLUG GROOVE ANGLE, 1 AS SOLVENT CEMENT THERMOMETER, LINE MOUNT ROOT OPENING CONTOUR SYMBOL INCLUDED ANGLE I CROSSING LINES, NO CONNECTION AQUEOUS SOLUTION —PHW PROCESS HOT WATERK DEPTH OF FILLING FINISH SYMBOL OF COUNTERSINK I I DIRECTION OF FLOW SPRING HANGER THERMOMETER, SEPARABLE WELL MOUNT FOR PLUG AND SLOT WELDS FOR PLUGWELD —A(250)- COMPRESSED AIR, 250 PSI —PTW PROCESS TEMPERED WATER —�f� LENGTH OF WELD SLOPE C T TRAP, FLOAT EFFECTIVE / DIRECTION OF SLOPE, DOWN CONDENSATE RETURN (GRAVITY) —PHWC— PROCESS HOT WATER CIRCULATING --I F— UNION, FLANGED THROAT F,l PITCH (CENTER TO CENTER SPACING) Av CD RL REFRIGERANT LIQUID TP TRAP SEAL PRIMER VALVE SIZE OR OF WELDS EQUIPMENT MARK NUMBER CHEMICAL DRAIN —1 11— UNION, SCREWED A STRENGTH FOR EXIST EXISTING WORK CF —1V- 1— UNCLASSIFIED VALVE CERTAIN WELDS R FIELD WELD SYMBOL CHEMICAL FEED RS REFRIGERANT SUCTION (GAS) WELDED FITTING /////// EXISTING TO BE REMOVED CHILLED WATER RETURN ARROW CONNECTING —CHWR— RWL— RAIN WATER LEADER o o SOLDERED FITTING VACUUM BREAKER S (E){p, oREFERENCE N}L—PTO LINE ARROW SIDE HIDDEN OR BELOW GRADE CHILLED WATER SUPPLY A 1>s OR ARROW SIDE — — —CHWs— S SPRINKLER LINE VACUUM DROP (LAB VAC) mi Pj N } MEMBER OF JOINT RECIRCULATING PUMP CLD CLEAR WATER DRAIN SAN— --`40---IN-LINE SANITARY WASTE ABOVE GRADE OR FLOOR PIPING SPECIALTIES Ov VACUUM OUTLET (LAB VAC) HARD PIPED (N) ( 1— INSULATED PIPE COOLING WATER RETURN SAN-- SANITARY WASTE BELOW GRADE OR FLOOR WELD ALL AROUND —CLWR— -- SYMBOL DESCRIPTION I i I VACUUM CLEANING OUTLET SYMBOL —6 1-- INSULATED PIPE WITH ELECTRIC HEAT TRACING —CLWS— COOLING WATER SUPPLY SPD— SUMP PUMP DISCHARGE 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR O VALVE BOX —FA ELEMENTS IN THIS AREA REFERENCE LINE REMAIN AS SHOWN WHEN NEW WORK CRV CORROSION RESISTANT VENT VALVE IN RISER (TYPE SPECIFIED)TAIL ANDDVARROD ARE ANEW STM — STEAM SUPPLY II 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR -KC -I NUMBER OF SPOT OR RESE -.aW PROJECTION POINT OF CONNECTION CRW CORROSION RESISTANT WASTE GRADE T WATER HAMMER ARRESTOR WELDS POC -- STS-- STORM DRAIN BELOW A /A AIR DROP - HOSE, SIMPLEX / DUPLEX \BADETAIL OR --fl PUMP — CTFR— COOLING TOWER FILTER RETURN --- TP --- TRAP PRIMER e / ® AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX WYE STRAINER (WITH DRAIN VALVE) REFERENCED — CTFS— COOLING TOWER FILTER SUPPLY --- V-- VENT �j CO ANGLE GLOBE VALVE, ELEVATION PLAN / TAIL MAYBE OMMITTED WHEN REFE ENCE IS NOT USED O VALVE —CTWR— COOLING TOWER WATER RETURN FIRE PROTECTION —VAC VACUUM400 (NUMBERCFLOW INDICATESPM)L ) SPECIFICATIONS, PROCESS OR OTHER REFERENCE FIXTURES -CTWS— COOLING TOWER WATER SUPPLY VPD— VACUUM PUMP DISCHARGE AAV AUTOMATIC AIR VENT (WITH DRAIN) SYMBOL DESCRIPTION CW DOMESTIC COLD WATER BACKFLOW PREVENTER EARTHQUAKE BRACING BACK WELD SYMBOL DESCRIPTION —I BFP I— a 2 WAY WASHFOUNTAIN DEIONIZED WATER 1*1 FILLET WELD 0 CIRCULAR DI PIPE FITTINGS BALANCE VALVE WITH METERING PORTS X 4 WAY EARTHQUAKE BRACING L ALV ® SEMI -CIRCULAR WASHFOUNTAIN DW DISTILLED WATER SYMBOL DESCRIPTION 1>14 BALANCE VALVE W/O METERING PORTS 0 ALARM VALVE, WET Ii PLUG OR SLOT WELD WATER F BELL & SPIGOT AUTOMATIC SPRINKLER RISER SQUARE WELD LI ELECTRIC COOLER FIRE LINE, AHEAD OF ALARM VALVE ) ) -10F/-1 1- BALL VALVE, OPEN / CLOSED ® ASR 11 FH FIRE HOSE CABINET PIPING BLIND FLANGE BUTTERFLY VALVE O SPOT OR PROJECTION WELD Q LAVATORY, ROUND COUNTER MOUNT --II fdl— 10 DRY PIPE VALVE.. FUEL OIL RETURN BUSHING r. • LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT FOR —1> COOLING COIL CHILLED WATER ELECTRIC BELL EXPANSION JOINTDG�1 GRD (OFD) ROOF DRAIN (OVERFLOW DRAIN - ROOF) — FOS— FUEL OIL SUPPLY FLOAT VALVE - EXISTING SPRINKLER HEADS (TO REMAIN) FOV— FUEL VENT FLANGED FITTING SPRINKLER 0 SAFETY EYE WASH FOUNTAIN — OIL -II— —4 FLOWMETER, VENTURI TYPE X X EXISTING HEADS (REMOVE) 1 °.1 SAFETY SHOWER AND EYE WASH G FLEXIBLE PIPE CONNECTION --11 FLOWMETER ORIFICE NATURAL GAS _••_ 1 F— FHC FIRE HOSE CABINET +; SERVICE SINK, FLOOR MOUNT GASEOUS NITROGEN 'GC GROOVED COUPLING -1>4-/ FDC c' ul GN2 GATE VALVE, OPEN / CLOSE FIRE DEPARTMENT CONNECTION, WALL TYPE SERVICE SINK, WALL HUNG — HGD — REFRIGERANT HOT GAS DISCHARGE HOSE BIBB GATE VALVE, OUTSIDE SCREW AND YOKE 4FDC 00. FIRE DEPARTMENT CONNECTION, YARD TYPE B SHOWER AND FIXTURE HPC GATE VALVE, WITH HOSE CONNECTION FDC STALL — — CONDENSATE, STEAM (HIGH PRESSURE) N HOSE BIBB - NON FREEZE DO LJ FIRE DEPARTMENT CONNECTION, FLUSH HB URINAL, WALL HUNG HPR— CONDENSATE RETURN PRESSURE) PIPE ANCHOR FIRE HYDRANT - 2 HOSE OUTLET — (HIGH X -02l-/-t»1- GLOBE VALVE, OPEN / CLOSED FH FIRE HYDRANT - 2 HOSE OUTLET GENERAL NOTES: p WATER CLOSET, WALL HUNG HPS— STEAM SUPPLY PRESS, 125-250 PSIG) PIPE CAP SCREWED OR SOLDER JOINT — (HIGH HEATING COIL FH AND PUMPER CONNECTION WATER FLOOR cJ CLOSET, MOUNT —HPW — HOT PROCESS WATER D PIPE CAP, WELDED OR GROOVED -N- / * LIFT CHECK VALVE FS FLOW SWITCH 1. SOME ABBREVIATIONS AND SYMBOLS INCLUDED IN THIS PIPE CROSS LEGEND MAY NOT BE FOUND ON ANY DRAWINGS. THEY —HPWC— HOT PROCESS WATER CIRCULATING III .MAV MANUAL AIR VENT (WITH DRAIN) O HALON SYSTEM AUTOMATIC DISCHARGE STATION ARE INCLUDED HERE AS PART OF A STANDARD LEGEND AND MAY BE UTILIZED IN THE FUTURE. HW DOMESTIC HOT WATER SUPPLY SR PIPE ELBOW, 90° SHORT RADIUS I:4 MOTOR OPERATED VALVE D HALON SYSTEM, MANUAL DISCHARGE STATION HWC— DOMESTIC HOT WATER CIRCULATING- 90° LONG NEEDLE VALVE___EbEc PIPE ELBOW, RADIUS 4 GROOVED COUPLING, GROOVED CAP HWR— HEATING WATER RETURN hi 0 NITROGEN DROP M MONITOR SWITCH PIPE ELBOW, REDUCING PIV HWS— HEATING WATER SUPPLY I O NITROGEN OUTLET WASTE FITTINGS \ PIPE ELBOW, 45° I POST INDICATOR VALVE, YARD SYMBOL DESCRIPTION IA INSTRUMENT AIR 10 PIPE ELBOW, TURNED UP OR TOWARD PETCOCK SPRINKLER HEAD, DRY PENDENT "±).. 1/4 BEND ID INDIRECT DRAIN —f0 AWAY +I FE —O PIPE ELBOW, TURNED DOWN OR PETE'S PLUG, WITH BALL VALVE SPRINKLER HEAD, OVER AND UNDER co IW INDUSTRIAL WASTE PIPE GUIDE --11 CLEAN OUT, EXPOSED = —111— PLUG VALVE/STOP COCK SPRINKLER HEAD, PENDENT, IN LINE, NEW FCO INDUSTRIAL PIPE HANGER —0 CLEAN OUT, FLOOR PIW— WASTE (PUMPED) X PRESSURE GAUGE WITH VALVE IF— SPRINKLER HEAD, PENDENT, OFFSET, NEW REVIEWED FOR X Y 7 0 1 33 CODE COMPLIANCE wco CLEAN OUT, WALL LN2 LIQUID NITROGEN 1 PIPING MATERIAL CHANGE, X TO Y 01 PRESSURE REGULATING VALVE W/EXT PRESS TAPI SPRINKLER HEAD, SIDEWALL, PENDENT, NEW PPROVED PIPE PLUG - 2 8 2091 0 FUNNEL FLOOR DRAIN LPC — CONDENSATE, STEAM (LOW PRESSURE) 14 A7 PRESSURE REGULATING VALVE (SELF CONTAINED) V SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW SEP FFD PIPE REDUCER CONCENTRIC 0 FUD FUNNEL DRAIN LPG — LIQUID PETROLEUM GAS —D PRESSURE RELIEF VALVE / SAFETY VALVE —0 SPRINKLER HEAD, UPRIGHT, NEW City of Tuiwila LPS STEAM SUPPLY PRESS, 0-15 PSIG) PIPE REDUCER ECCENTRIC BUILDING DIVISION 0 FLOOR DRAIN — (LOW D>GI QUICK OPENING VALVE THRUST BLOCK FD Fal MPC CONDENSATE, STEAM (MEDIUM PRESSURE) PIPE SUPPORT FS FLOOR SINK — D> QUICK CLOSING VALVE, FUSIBLE LINK $WIV WALL INDICATOR VALVE, PLAN / ELEVATION OFFMAN RECEIVED I LATERAL MPS STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) I+I SOLENOID OPERATED VALVE T' WMG WATER MOTOR GONG CITY �I — PIPE TEE, STRAIGHT —pl� N G I N E E R S OF TUKWILA Fifth Avenue, Suite 9001 Seattle, WA 98101x-01 I I ICI I 1 TRENCH DRAIN OFD — OVERFLOW DRAIN —1601 PIPE TEE, UP OR TOWARD —rr STEAM TRAP T TAMPER SWITCH ph 206.623.0717 I fax 206.624.3775 SEP 2 0 2017 coffman.com DO WASTE RECEPTOR, ROOF PA PAINT BOOTH SERVICE AIR REDUCING PIPE FLANGE LASTING creativity! melts 1melatlonships PERMIT CENTER WR — —ID SWING CHECK VALVE WITH FLOW 1111co WYE BEND, SHOWN WITH CLEAN OUT —PCWS— PROCESS COOLING WATER SUPPLY AND 1/8 101 PIPE TEE, DOWN OR AWAY PCWP— PROCESS COOLING WATER RETURN SCREWED FITTING OR AS SPECIFIED 07.12.2017 1 1 PC CONDENSATE RETURN /S (PUMPED) SEISMIC HANGER ISSUE FOR CONSTRUCTION SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ilti m i . . _A )ffA El ivirM r' ® L Sp G� � .. ,►�• „ • ;� ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN CEI DATE 05.02.17 SUBTITLE PIPING LEGEND CURRENT REVISION w4618793 SYMBOL - DATE 07.12.17 CHECKED TB 05.02.17 - REOPEN GATE J8 W4618793 CEI TB 07.12.17 SHEET Ivl ENGINEER TITLE REOPEN GATE J8 BUILDING 09-056 MECHANICAL MASTER COL. X-X/X-X DEV, CENTER, WA APPROVED BY DEPT. DATE �36611 � `�SjONAL �� CHECKED JOB N0. W4618793 COMP N0. APPROVED DWG N0. 09-056-M1B APPROVED 7/11 /17 SYM REVISION ORIG REOPEN GATE J8 W4618793 BY CEI APPROVED DATE SYM HEAT PUMP SCHEDULE UNIT NO. AREA SERVED PAIRED UNIT MAKE MODEL UNIT SIZE (TONS) SEEER HSPF COP LIQUID (IN.) SUCTION (IN.) ELECTRICAL SOUND dB(A) WEIGHT (LBS.) REMARKS VOLTS PH AMPS CU -1 GUARD SHACK FCU -1 DAIKIN RXL09QMVJU 0.75 20 11.7 4.1 1/4 3/8 208 1 3.61 49 60 1,2 NOTES: 1. UNIT TO BE MOUNTED OUTSIDE ON CONCRETE SLAB 2. REFRIGERANT R -410A, CHARGED TO 2.09 LBS FAN COIL UNIT SCHEDULE UNIT NO. AREA SERVED MAKE MODEL TYPE COOLING COIL TOTAL (BTU/H) FAN CFM (RANGE) ELECTRICAL (LBS) REMARKS VOLTS PHASE AMPS FCU -1 GUARD SHACK DAIKIN FVXSO9NVJU SPLIT SYSTEM 9,000 145-290 208 1 0.14 31 1,2,3 NOTES: 1. ELECTRICAL DISCONNECT BY ELECTRICAL CONTRACTOR. 2. PROVIDE WITH WALL MOUNTED, PROGRAMMABLE THERMOSTAT. 3. ECONOMIZER EXCEPTION: COOLING UNITS AND SPLIT SYSTEMS WITH A TOTAL COOLING CAPACITY RATED IN ACCORDANCE WITH SECTION C403.2.3 OF LESS THAN 33,000 BTU/H REVISION CONDENSING UNIT REFRIGERANT PIPING FAN COIL UNIT DRAIN BY 2 3 NECHA\ICAC PLA\ SCALE: 1/2"= 1'-0" APPROVED DATE MS 07.12.17 ROOF LINE ABOVE CONCRETE PAD Q� BOE/NG° (Y - 7/11117 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED BY DEPT. APPROVED DATE DRAWN CEI &LCOFFMAN NGINEERS 1601 Fifth Avenue, Suite 9001 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity 1 results 1 relationships LEGE\D GE\EAL \OTES EFEH\CE DW\WI\GS CO \STUCTIC\ \OTES PROVIDE NEW FAN COIL UNIT. PROVIDE NEW CONDENSING UNIT. PROVIDE NEW PROGRAMMABLE T'STAT. PROVIDE NEW REFRIGERANT PIPING WITH CLOSE -CELL INSULATION AND ALUMINUM JACKET ON EXTERIOR PIPING. PROVIDE NEW 1" COPPER DRAIN PIPE WITH TRAP. LOCATE TRAP INSIDE OF GUARD SHACK. 6. MAINTAIN 9" OF CLEARANCE BETWEEN CU -1 AND NORTH WALL OF GUARD SHACK. M3s JIIIIII REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 S 2017 City of Tukwila BUILDING DIVISION 07.12.2017 ISSUE FOR CONSTRUCTION DATE 05.02.17 TRICKED MS 05.02.17 SUBTITLE MECHANICAL PLAN GATE J-8 GUARD BLDG KEYPLAN SCALE: NONE CURRENT REVISION W4618793 IVED UKWILA 2 0 2017 PERMIT CENTER SYMBOL0 sic DATE 07.12.17 ENGINEER MS CHECKED APPROVED APPROVED 05.02.17 TITLE MECHANICAL MASTER REOPEN GATE J8 BUILDING 09-056 DEV, CENTER, WA SHEET M500 JOB NO. W4618793 COMP NO. DWG NO. 09-056-M500