Loading...
HomeMy WebLinkAboutPermit M17-0138 - SAHALE SNACKS - DUCTLESS SPLIT SYSTEMS, CONDENSERS, EVAPORATORSSAHALE SNACKS 3411 S 120 PL M17-0138 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 1023049069 Permit Number: 3411 S 120TH PL 100 Issue Date: Permit Expires On: Project Name: SAHALE SNACKS M17-0138 10/23/2017 4/21/2018 Owner: Name: Address: SABEY CORPORATION 12201 TUKWILA INTL BLVD 4THFL , ' SEATTLE, WA, 98168 Contact Person: Name: JARROD LONGMIRE Address: Contractor: Name: Address: License No: Lender: Name: Address: 12646 INTERURBAN AVE S , SEATTLE, WA, 98168 TCMS OF SEATTLE LLC PO BOX 11252 , PORTLAND, OR, 97211 TCMSSSL905CB !/I Phone: (206) 588-8787 Phone: (570) 928-5613 Expiration Date: 2/10/2018 DESCRIPTION OF WORK: INSTALLING TWO HIGH EFFICIENCY DUCTLESS SPLIT SYSTEMS TO STORAGE AREA, SETTING THE CONDENSERS ON THE ROOF AND •THE EVAPORATORS IN THE CEILING Valuation of Work: $28,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $587.73 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: ' ® — ?5-1 7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this developmentp mit and agree to the conditions attached to this permit. Signature: Print Name: l Onl� ‘•r� Date: /0'Z3- 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0609 0705 0701 MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. �r —0130 Project No. Date Application Accepted: Date Application Expires: -.L5I7 3^2-s -� (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 3411 South 120th Place Tukwila Wa. Suite Number: CO Floor: Tenant Name: Sahale Snacks PROPERTY OWNER Name: Sabey Corp. Address: 12201 Tukwila International Blvd, City Seattle State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Karl Sanders Address: 3411 S. 120th Place City: Tukwila State: WA. Zip: - Phone: (206) 456-7493 Fax: Email: karl.sanders@jmsmuckers.com New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: TCMS of Seattle Address: 12646 Interurban Ave. S City: Seattle State: WA Zip: 98168 Phone: (206) 588-8787 Fax: (206) 588-8998 Contr Reg No.: 602845504 Exp Date: 07/18/2018 Tukwila Business License No.: 0996773 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Installing two high eff. ductless split systems to storage area, setting the condenser's on the roof and the evaporators in the ceiling 28,000 Use: Residential: New ❑ Replacement ❑ Commercial: New 121 Replacement ❑ Fuel Type: Electric 0 Gas ❑ Other: Ductless split system H:Wpplications\Porms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type • Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 2 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 2 Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 2 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source - District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. 'Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Ol>l AUTIORIZED AGENT: Signature: Date: 9/Z$/i% Print Name: Jarrod Longmi Day Telephone: (206) 454-9413 Mailing Address: 12646 Interurban Ave. S H:\ApplicationsWonns-Applications On Line\2016 Applications\Mcchanial Permit Application Revised 1.4.16.docx Revised: January 2016 bh Seattle WA. 98168 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $587.73 M17-0138. Address: 3411 S 120TH PL 100 Apn: 1023049069 $587.73 Credit Card Fee$17.12 Credit Card Fee R000.369.908.00.00 0.00 $17.12 MECHANICAL $548.66 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $405.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $109.73 TECHNOLOGY FEE $21.95 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12414 • R000.322.900.04.00 0.00 $21.95 $587.73 Date Paid: Monday, September 25, 2017 Paid By: JAROD LONGMIRE Pay Method: CREDIT CARD 683069 Printed: Monday, September 25, 2017 2:28 PM 1 of 1 CSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit MI7- N3,' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: _S h,qLe -� =.Ks Type of Inspection: r1,11cc \ FI Aec., Address: Date Called: r—. 3 t I S 120 �-- F1 leo Special Instructions: ', Date Wanted: Li- 7- efrn. * Gi6E'f�(ag-r�it'/y I& p.m. Requester: h Lej# t o %'i t%`s:,[„ 0 Phone No: / G Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: oK - Rbt) /+' iii M;eC l'r(At, K- ifaieg 6-9 c)K- t -c__ i1/ Crkfl-Mc.-L Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Gr8ectrical Eg'Plumbing Inas Piping City of Tukwila BUILDING G DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No. Nl(7-013) Plan review approval is subject to errors and on ons. Approval of constriction documents does not authorize the violates of any, adopt code or ordnance. Receipt of approved Ref E ,.; ; , is ackromfedgect City of Tukwila BUILDING DIVISION x"1 11- d 1 3 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 8 2011 City of Tukwila Ra.Q tt BION MECHANICAL SYMBOLS LEGEND HYDRONIC SYSTEM LABELS REFERENCE SYMBOLS PIPE BREAK (CONTINUATION) HYDRONIC SUPPLY HYDRONIC RETURN DIRECTION OF FLOW CAP HEAT TRACED PIPING HYDRONIC VALVES AND SPECIALTIES 2 -WAY ELECTRIC CONTROL VALVE FAIL OPEN FAIL CLOSED DETAIL NUMBER SHEET FLAG NOTE REVISION TAG MECHANICAL EQUIPMENT DIFFUSER/GRILLE TYPE CFM SECTION NUMBER SHEET NUMBER 3 -WAY: ELECTRIC CONTROL VALVE : CEILING RADIATION DAMPER 43. OR COMBINATION SMOKE/FIRE DAMPER DUCTWORK LABELS -.--* 16X12 INTERNALLY.UNED DUCT HIDDEN DUCT DUCT (1ST DIMENSION SIDE SHOWN, 2NDDIMENSION OTHER SIDE) REMOVE DUCT, PIPE OR MECH..EQUIPMENT FLEX DUCT m RECTANGULAR SUPPLY DUCT OUT OF PAGE RECTANGULAR SUPPLY DUCT INTO PAGE • SUPPLY DIFFUSER RECTANGULAR RETURN DUCT OUT OF PAGE RECTANGULAR RETURN DUCT INTO PAGE 0 OR . RETURN OR EXHAUST GRILLE to TURNING VANES STRAIGHT TAP TAPERED FITTING BELL MOUTH FITTING CONICAL FITTING 45 DEG. ANGLE TAP ROUND ELBOW OUT OF PAGE • ROUND ELBOW INTO PAGE ROUND DUCT OUT OF PAGE ROUND DUCT.INTO PAGE ROUND DUCT BREAK (CONTINUATION) RECTANGULAR DUCT BREAK (CONTINUATION) FLEX CONNECTION VOLUME DAMPER MOTORIZED CONTROL DAMPER . . THERMOSTAT IN DUCT REMOTE OPERATED VOLUME DAMPER' BACKDRAFTDAMPER PRESSURE INDEPENDENT VOLUME DAMPER (TROX VFL) PRESSURE INDEPENDENT VOLUME CONTROLLER (IROX VFC) PRESSURE INDEPENDENT VOLUME CONTROLLER W/ ACTUATOR (TROX VFC E0 /M0) THERMOSTAT, MOUNT (g.4'-0" A.F.F. SENSOR CARBON MONOXIDE DETECTOR WITH FAN INDICATED CARBON DIOXIDE DETECTOR PIPING SYSTEM LABELS G n itt Tor TAY NATURAL GAS OR PROPANE BALL VALVE MANUAL LEVER BUTTERFLY VALVE MANUAL LEVER BUTTERFLY GEAR VALVE GLOBE VALVE MANUAL LEVER BALANCE VALVE (CIRCUIT SETTER) BALANCE VALVE (PRESSURE INDEPENDENT) PIPE TO DRAIN PRESSURE SAFETY VALVE AUTOMATIC AIR VENT MANUAL AIR VENT WYE STRAINER WYE STRAINER VdTH VALVE AND HOSE END CAP HEAT TRACE PIPING HOSE END AND CAP EXPANSION LOOP HVAC ENERGY CODE NOTES 1: SEE SCHEDULES FOR EQUIPMENT TYPE, CAPACITYANDEFFICIENCY. ALL. EQUIPMENT SHALL MEET MINIMUM EFFICIENCY PER C403.2.3. - 2. THERMOSTATICGCONTROLS IN THE SAME ZONE OR IN NEIGHBORING ZONES CONNECTED BY OPENINGS. LARGER THAN 10% OF THE FLOOR AREA OF EITHER ZONE SHALL BE INTERLOCKED TO-NOTACLOW SIMULTANEOUS HEATING AND COOLING. 3. HEAT PUMPSWITH.SUPPLEMENTARYELECTRIC.HEAT SHALL INCLUDE MICROPROCESSOR.CONTROLS THAT MINIMIZE ELECTRIC. HEAT USAGE DURING START-UP, SET-UP, ANDDEFROST CONDITIONS. CONTROLS SHALL'ANTICIPATE NEED FOR HEAT AND USE COMPRESSION HEATING AS THE FIRST STAGE.'. CONTROLS SHALL INDICATE WHEN ELECTRIC HEAT IS BEING USED THROUGH VISUAL MEANS. • ELECTRIC HEAT SHALL:NOTOPERATE-ABOVE 40 F OUTSIDE AIR TEMPERATURE. 4. THERMOSTATIC. CONTROLS SHALL BE CONFIGURED WITH AT LEAST A 5F-DEADBAND'BETWEEN HEATING AND COOLING SETPOINTS. . THERMOSTATS (OTHER THAN GROUP R) SHALL BE 7-DAY.PROGRAMMABLEWITH AUTOMATIC SETBACK CONTROLS SET DOWN TO 55F AND UP TO 85F. CONTROLS SHALLMAINTAIN PROGRAMMING FOR AT LEAST•10 HOURS -DURING LOSS OF POWER. CONTROLS SHALL HAVE A. MANUAL 2 HR OVERRIDE:FOR TEMPORARY' OPERATION. CONTROLS SHALL ADJUST THE DAILY START TIME FOR MORNING WARMUP •PRIOR TO SCHEDULED -OCCUPANCY. • PROVIDE •AMCA CLASS 1 -MOTORIZEDCONTROL DAMPERS FOR OUTSIDE AIR INTAKES, EXHAUST OUTLETS, RELIEF OPENINGS, STAIRWAY AND SHAFT VENTS AND.RETURN SIDE OF AIRSIDE ECONOMIZERS... • •: . AIR-COOLED UNITARY DIRECT. -EXPANSION UNITS WITH A COOLING. CAPACITY OF 54 MBH OR. GREATER THAT ARE EQUIPPED WITH AN.1ECONOMIZERSHALLINCLUDE-FAULTOETECTON'ANDOIAGNOSTICS(FDD). •• PROVIDE. GAS-FIRED HEATING' EQUIPMENT WITH MODULATING OR STAGED COMBUSTION CONTROL FOR ALL EQUIPMENT OVER . 225 MBH- . 8.. THERMOSTATS (GROUP. R) SHALL BE 5-2 ITH PROGRAMMABLE.SCHEDULE WATLEAST 2 SETBACK PERIODS PER DAY. 10: PROVIDE DUCT, SHAFT AND PLENUM INSULATION PER C403;2.8 MID SPECIFICATION. SECTION 23 0700. 11. SEAL' ALL TRANSVERSE AND LONGITUDINAL SEAMS, JOINTS: AND CONNECTIONS OF ALL DUCTWORK WITH WELDS, GASKETS OR 12. PROVIDE PIPE INSULATION PER ENERGY. CODE SECTION C493:2.9 AND SPECIFICATION SECTION 23 07 00: :: - - - - INSULATION EXPOSED TO WEATHER SHALL BE. PROTECTED FROM DAMAGE, SUNLIGHT; MOISTURE AND WIND. PROVIDE JACKET 13' AND ALUMINUM COVERS. -ADHESIVE:TAPE-IS NOT PERMITTED... • • : - - • • • - • _ 14: SINGLE FAN OR MULTIPLE. PANS IN PARALLEL WITH COMBINED -MOTOR NAMEPLATE OVER 5HP SHALL HAVE A FAN -EFFICIENCY - GRADE(FEG) OF 67 OR HIGHER AND -SHALL BE SELECTED TQ OPERATE WITHIN 15% OF THE MAXIMUM TOTAL EFFICIENCY OF THE FAN..• :. f:. -. .: - - _ 15. COOLING SYSTEMS. 85 MBH AND GREATER SHALL HAVE TWO SPEED FAN CONTROL OR MODULATING FAN CONTROL. 18. FANAND PUMP MOTORS 7.5 HP AND GREATER SHALL -BE PROVIDED WITH A VFD. - - - . 17. ECONOMIZERS SHALL BE INTEGRATED WITH MECHANICAL COOLING AND SHALL BE CAPABLE OF PROVIDING PARTIAL ECONOMIZER COOLING EVEN WHEN.ADDITIONALMECHANICAL COOLING IS,REQUIRED: - • • L. 18.-AIRECONOMIZERS.SHALL HAVE. FIXED DRY-BULB. HIGH-LIMITSHUTOFF CONTROLNOT TO EXCEED 75 DEG. -F.. 19. ALL ELECTRIC.MOTORS LL MEET THE EFFICIENCY REQUIREMENTS OF•TABLES C405.8(1)THROUGH C405.8(4). 20. FANMOTORSI/12 HP UP TO 1, HP SHALL BE ECM: - • - • : - 21: PROVIDE A MEANS'OF BALANCING EVERY AIR INLET AND OUTLET AND EVERY AIR OR WATER TERMINAL DEVICE. • 22. ALL -PIPE AND DUCT INSULATION SHALL BE LABELLED WITH ITS THICKNESS AND INSULATING'VALUE:(RORK).. • 5. 6. 7. HVAC GENERAL NOTES ACT ADA AW AFF AFG ALT AP APPROX ARCH AS AUX BFF. BHP BLDG BOP BTU BTUH CA CFH CFM CLG CO CO2 GOND CW CX dB DB °F • OR DEG. 0 O DIA D/L DN DWG(S) DWV -1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EEXACT ROUTING OR EVERY OFFSET, WHICH MAYBE REQUIRED: : - THEHVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO.VERIFY ALL CLEARANCES BEFORE - COMMENCING WORK. - - - - 2. MATERIALS, METHODS AND INSTALLATION' SHALL COMPLY -WITH -THE PROVISIONS OFTHELATEST EDITION OF THE - - INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE,• INTERNATIONAL FIRE: CODE - - - AND. LOCAL CODES AND•ORDINANCES. - - . . 3. DUCT. CONSTRUCTION AND HANGING SHALL COMPLY WITH THE LATEST IMC AND WITH CURRENT SMACNA STANDARDS.. . 4. JOINTS OF. DUCT SYSTEM SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT -SEALANT.. 5. -.DUCTS SHALL BE INSULATED AS INDICATED ON.PLANS TO MEET THE REQUIREMENTS OF THE CURRENT INTERNATIONAL ENERGY CODE SPECIFICATION. 6. FLEXIBLE'DUCTS SHALL ONLY:. BE USED. WHERE -SHOWN AND -SHALL NOT EXCEED;6. FT.IN LENGTH UNLESS : NOTED OTHERIMSE, 7. PROVIDE:EARTHQUAKE.RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH .THE CURRENTBC. '8.- PIPING PENETRATIONS OP -FIRE RATED WALLS OR -FLOOR SHALL BE SLEEVED AND FIRE WITH LISTED.MATERIALS SO AS TO MAINTAIN. THE INTEGRITY: AND. RATING OP THE FLOOR OR WALL • . . .9. PROVIDE RETURN DUCT. SMOKE •DETECTOR(S) FO.R AUTOMATIC•SHUT DOWNOF ALL HEATING OR COOLING'' EQUIPMENT . DELIVERING:IN EXCESS OF 2000 CFM IN ACCORDANCE WITH THE CURRENT INTERNATIONAL MECHANICAL CODE. POWER - WIRING AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS•BY THE ELECTRICAL CONTRACTOR:. 10. HVAC EQUIPMENT, VALVES -AND' DAMPERS SHALL BE LOCATED IN EASILY -ACCESSIBLE LOCATIONS,- UNLESS SHOWN ON . .ARCHITECTURALDRAWINGS. REQUIRED ACCESS PANELS SHALL BE PROVIDED BY THE -HVAC CONTRACTOR AND - • INSTALLED BY THE GENERAL CONTRACTOR. •- - - 11. HVAC CONTRACTOR MUST COORDINATE WITH LIGHTING FIXTURES PRIOR TO DUCT AND PIPING INSTALLATION. . REVIEWED FOR CODE COMPLIANCE APPROVED SEP 1017 CIS of TWEte^ kg RECEIVED CITY OF TUKWILA SEP 2 5 2017 PERMIT CENTER iT7O -138 EX EA . . EA EAT ERU ESP ET EXP ABBREVIATIONS . ACOUSTICAL CEILING TILE MEP AMERICANS WITH DISABILITIES ACT. ADJUSTABLE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ALTERNATE ACCESS PANEL APPROXIMATE ARCHITECTURAUARCHFTECT AIRSEPARATOR AUXILIARY BELOW FINISHED FLOOR BRAKE HORSE POWER BUILDING.. BOTTOM OF PIPE BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR COMBUSTION AIR CUBIC FEET PER HOUR CUBIC FEET PER MINUTE CEIUNG CARBON MONOXIDE CARBON DIOXIDE. CONDENSATE COLD WATER CONNECT TO EXISTING DECIBEL DRY BULB TEMPERATURE DEGREE DIAMETER DOOR LOUVER DOWN DRAWINGS) DRAIN, WASTE, WAIT EASING/EXISTING TO REMAIN EACH EXHAUST AIR ENTERING AIR TEMPERATURE ENERGY RECOVERY. UNIT EXTERNAL STATIC PRESSURE EXPANSION TANK EXPANSION' FC FAIL CLOSED FF FINISHED FLOOR FLA FULL LOAD AMPS FO - FAIL OPEN FP , . ' FIRE PROTECTION FPM : FEET PER MINUT .. . FPS . FEET PER SECOND FT . - FEET/FOOT FTGFOOTING G NATURAL GAS GA 'GAUGE GAL ' GALLON GALV GALVANIZED _ - G.C. GENERAL CONTRACTOR GSM GALVANIZED SHEET METAL H HD HP HVAC HW HX HZ HEIGHT - - - HEAD. HORSEPOWER HEATING VENTILATING AND AIR CONDITIONING. HOT WATER HEAT EXCHANGER HERTZ ID ' - - INSIDE DIAMETER/DIMENSION. IN INCH/INCHES IN WC INCHES WATER COLUMN KW KILOWATT/KILOWATTS LAT LBS LF LRA. LTG LWT MBH LEAVING AIR TEMPERATURE POUNDS UNEAL FOOT LOCKED ROTOR AMPS LIGHTING LEAVING WATER TEMPERATURE 1000 BRITISH THERMAL UNIT PER HOUR MED MEDIUM MEZZ MIN MISC HA NC NEG NIC NO NOM NPT NTS OA 080 OC OD OFCI OF01 AP PERF. •MORPH . PLBG POC .PRESS • PRV. PSF PSI. PSIG PTHC • QTY REQD. RH RM RPBP RPM RLX RTU RV. • RX • SD SF S.L SP SPEC • S/S, OR SS STD SYM T8P TBD TEMP TOB TOC TOD TOJ TOS T8P TSP TYP UL UNO V VAV VERT VFD VIB VOL W/ W/IN W/O We WC WPD WT MECHANICAL ELECTRICAL B PLUMBING .. MEZZANINE MINIMUM OR MINUTE MISCELLANEOUS NOT APPLICABLE NORMALLY -CLOSED NEGATIVE NOT IN CONTRACT NORMALLY OPEN NOMINAL NATIONAL PIPE THREAD NOT TO SCALE OUTSIDE AIR OPEN BLADE DAMPER ON CENTER OUTSIDE DIAMETER OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED - - OWNER. INSTALLED PRESSURE' DIFFERENTIAL PERFORATED. PHASE PLUMBING. POINT OF, CONNECTION PRESSURE PRESSURE REDUCING VALVE POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POUNDS PER INCH GAUGE. PACKAGE TERMINAL AIR CONDITIONER REQUIRED RELATIVE HUMIDITY ROOM REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTIONS. PER MINUTE RELOCATE EXISTING - ROOF TOP UNIT RELIEF VALVE REMOVE EXISTING SMOKE DETECTOR SQUARE FOOT SOUND.UNER STATIC PRESSURE SPECIFICATION STAINLESS STEEL STANDARD SYMBOL TEMPERATURE AND PRESSURE REUEF VALVE - TO BE DETERMINED TEMPERATURE TOP OF BEAM TOP OF,CONCRETE TOP OF DECK - TOP OF JOIST TOP OF SLAB/TOP-OF STEEL : : TEMPERATURE & PRESSURE - TOTAL STATIC PRESSURE. - - TYPICAL • UNDERWRITERS LABORATORY- _ UNLESS NOTED -OTHERWISE. VOLT VARIABLE AIR VOLUME - VERTICAL VARIABLE FREQUENCY DRIVE VALVE -IN -BOX VOLUME !ITN WITHIN VNTH0LJr . WET BULB TEMPERATURE WATER COLUMN WATER PRESSURE DROP WEIGHT : SIDER -BYERS 192 Nickerson, SUBe /100 Seattle, Washington. 98109 Phone: 206.285.2966 Fax 206.285.1045 STORAGE ors COVER SHEET wow KS r:. NB se 9/1;/;7 son. AS NOTED 17061 M1 1 REFRIGERANT PIPING AND CONDUITS. -7 END COVER CAULK PENETRATIONS. WATERTIGHT. 16" HEIGHT CURB • WEATHER TIGHT ACCESS PANEL OVER TOP. 18 GA. ALUMINUM. ATTACH AND FLASH TO CURB. ROOF FLASHING AND COUNTER FLASHING BY OTHERS.. ROOF — PACK BATT INSULATION.. SOUD AROUND PIPING. FULL HEIGHT OF CURB. NOTE SIMILAR DETAIL FOR CONDENSER WATER P PING FROM LEESON FLUID COOLER REFRIGERANT PIPE PORTAL N.T.B. FILL HOLE 8 SEAL AT GSM WITH SILICONE. %% Mow - SUPPORT BY OTHERS.. ANCHORED TO ROOF STRUCTURE. (VERIFY EXACT SIZE/QUANTITY OF FASTENERS) DETAIL TYPICAL FOR CONDENSING UNIT SUPPORT. BOLT EQUIPMENT TO.RAIL(VERIFY EXACT SIZE/QUANTITY OF • FASTENERS) EQUIPMENT NEOPRENE ISO PAD 22 GA. GSM CAP CANT BYOTHERS ROOFING OVER SUPPORT BY OTHERS RAIL SUPPORT DETAIL Scale: NONE THREADED ROD CLEVIS HANGER 6' VIDE, 26GA S/M SHIELD, OVERLAPPING PRE -INSULATED REFRIGERANT TUBING UNE SET. REFRIGERANT PIPE SUPPORT N.T.S. .I, 01221111 EX UGHT FIXTURE (FYI') REFRIGERANT PIPE. SIZE ' I� PER MFG'S REQUIREMENTS UNOCCUPIED STORAGE AREA (TYP) f STORAGE AREA - BELOW EX CARRIER SPUTSYSTEM 1 •: (1. PIPE PORTAL SEE DETAIL oo. HP -2 ate FLOOR PLAN S.CALE:1/4'01'-0' EX EXHAUST CAP 1 0 EX DIFFUSER OR • ,"4" GRILLE ABANDONED IN PLACE. DEMO AS NECESSARY (TYP) . . PIPE INDOOR UNIT CONDENSATE ONES TO EX WATER HEATER FLOOR DRAIN R`'VIENWED. FOR CODE COMPLIANCE APPROVED SEP 2 8 2017 Citi of Tukw . BUILDING OIVIOION r E001 J - ROOF PLAN SCALE:1/4'+T-0' EX FUJITSU PUT SYSTEM EX STRUCTURAL BEAM CITY OF TUKWILA SEP 2 5 2017 PERROT CENTER SPLIT SYSTEM HEAT PUMP UNIT SCHEDULE INDOOR UNIT OUTDOOR UNIT MARK SERVES MAKE MODEL SUPPLY - TOTAL ESP OSA CFM. W.C. - CFM- .. COOLING: . . TOTAL EAT . OAT. SEER EER: MBH DB I WB DB (AHRI) (AHRI) HEATING HEATING MBH COP - - - - 17 OAT . AT 47F VOLT / PH. MCA MOCP : ELECTRICAL SOUND dBA OP. WT. LBS. MARK MAKE MODEL ELECTRICAL VOLT 1 PH MCA SOUND PRESSURE dBA OP: NR.. LBS. NOTES HP -1 R&D STORAGE MITSUBISHI PLA-A24EA7 810 0 HP -2 R&D STORAGE MITSUBISHI PLA-A24EA7 810 0 0 0 19.5 19.5 80/67 80/67 24.2 14.3 4.35 208/1 1 15 24.2 14.3 15.8 4.35 208/1 1: 15 CU -1 CU -2 MITSUBISHI PUZ-A24NHA7 208/1 19 48 ALL MITSUBISHI PUZ-A24NHA7 208 / 1 19 48. ALL NOTES: .. 1. ROOM COOLING LOAD AS DETERMINED BY HEAT OUTPUT OF REFRIGERATION EQUIPMENT IN THE STORAGE SPACE 2. ECONOMIZER EXCEPTION C403.3 EXCEPTION.3 IN COMPLIANCE WITH TABLE C403.3 - - 3. INTERNAL CONDENSATE UFT - 4. PROVIDE WITH SMART ME THERMOSTAT - - - - - - 5. PROVIDE: INDOOR UNIT WITH TRIM PANEL SI DER - BYERS 06 0 ✓ KS .0 N8 NB out • 9111/17 m AS NOTED ▪ 17081 M2.1 From: , Jarrod Longmire Sent Wednesday; August 23, 2017,9:18 AM To: Jarrod Longmire Subject Sent from Snipping Tool. --J REVIEW:D :'O OD SEP 2 8 ,n ? City ofi'� ufwiile BUILDING DIVISIC; e 14'2 RECEIVED CITY OF �'JKWIL SEP 251..` PERMIT C1 1 P=SERIES SUBMITTAL DATA: PLA-A24EA7 & PUY-A24NHA7(-BS) ' MITSUBISHI 24,000 BTU/H CEILING -CASSETTE AIR-CONDITIONING SYSTEM M\ ELECTRIC Job Name: System Reference: Date: Indoor Unit: PLA-A24EA7 ` Outdoor Unit: ❑ PUY A24NHA7 ❑ PUY A24NHA7-BS if, REVIEWED INDOOR UNIT FEATURES • Space -efficient ductless installation • Equipped with 3D i -see SensorTM for enhanced comfort and energy efficiency . • Airflnw cc44inne fnr Rink and In\•/ rnilinn annlirafinne 1 FOR CODE COMPLIANCE APPROVED SEP 2 8 2017 • • Individual vane settings for direct/indirect airflow control or variable airflow patterns City of Tukwila • Knockouts for outside -air intake and branch -duct run BUILDING DIVISION • Filter indicator signal • Easy -to -clean, washable filter (optional high -efficiency filter available - requires multi -function casement) • Built-in condensate lift mechanism • Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • Suction accumulator pre -charged with refrigerant volume for piping length up to 100 ft (70 ft. for Al2/18/24/30) • Low ambient cooling down to -20°F providing 100% capacity (only for PUY models with wind baffles installed) • 24-hour continuous operation (cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers RECEIVED • Superior energy and operational efficiency CITY OF TUKWILA SEP 2 5 2017 PERMIT CENTER Mu7OL3� Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. SPECIFICATIONS: PLA-A24EA7 PUY-A24NHA7(-BS Model Number PLA-A24EA7 Indoor Gl i$3 Outdoor Igatp PUY-A24NHA7 PUY-A24NHA7-BS Cooling*1 Maximum Capacity Btu/h 24,000 Rated Capacity Btu/h 24,000 Minimum Capacity Btu/h 10,000 Maximum Power Input W 1,670 Rated Power Input W 1,670 Moisture Removal Pints/h 3.0 Sensible Heat Factor 0.86 Power Factor % 94.3 Efficiency SEER 24.2 EER *1 14.3 ENERGY STAR® Certified (ENERGY STAR products are third- party certified by an EPA -recognized Certification Body) Yes Electrical Voltage, Phase, Frequency 208 / 230V 1 -phase, 60 Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Voltage: Indoor - Outdoor, S2 -S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 Recommended Fuse/Breaker Size A 25 Recommended Wire Size (Indoor - Outdoor) AWG 14 Indoor Unit MCA A 1.00 Fan Motor Full Load Amperage A 0.60 Fan Motor Output W 120 Airflow Rate, Dry CFM 530-640-710-810 Airflow Rate, Wet CFM 490-600-670-770 External Static Pressure in.WG n/a Sound Pressure Level dB(A) 28-30-33-36 Drain Pipe Size In. (mm) 1-1/4 (32) Condensate Lift Mechanism, Max. Distance In. 33-7/16 Heat Exchanger Type Plate fin coil External Finish Color White Munsell 6.4Y 8.9/0.4 Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. SPECIFICATIONS: PLA-A24EA7 PUY-A24NHA7(-BS) Model Number PLA-A24EA+7 Indoor Imo} Outdoor IB PUY-A24NHAq PUY-A24NHA7-BS Unit Dimensions // Grille Dimensions W In. (mm) 33-1/16 (840) // 37-13/32 (950) D: In. (mm) 33-1/16 (840) // 37-13/32 (950) H: In. (mm) 11-3/4 (298) // 1-9/16 (40) Package Dimensions // Grille Dimensions W In. (mm) 35-9/16 // 39-6/16 D: In. (mm) 34-5/16 // 38-3/16 H: In. (mm) 16-9/16 // 4-12/16 Unit Weight // Grille. Weight Lbs. (kg) 56(25) // 11 (5) Package Weight Lbs. (kg) 68 (31) Indoor Unit Operating Temperature Range Cooling Intake Air Temp (Maximum / Minimum) °F 90 DB, 73 WB / 66 DB, 59 WB Outdoor Unit MCA A 19 MOCP A 26 Fan Motor Full Load Amperage A 0.40 Fan Motor Output W 86 Airflow Rate CFM 1,940 Refrigerant Control Electronic Expansion Valve Heat Exchanger Type. Cross fin Sound Pressure Level, Cooling*1 dB(A) 47 Sound Pressure Level, Heating*2 dB(A) 48 Compressor Type INVERTER -driven twin rotary Compressor Model SNB172FWHM1 Compressor Rated Load Amps A 7 Compressor Locked Rotor Amps A 11 Compressor Oil Type // Charge oz. FV5OS // 23 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a Unit Dimensions W In. (mm) 37-13/32 (950) D: In. (mm) 13 + 1-3/16 (330 + 30) H: In. (mm) 37-1/8 (943) Specifications are subject to change without notice. Copyright CO 2017 Mitsubishi Electric US, Inc. SPECIFICATIONS: PLA-A24EA7 PUY-A24NHA7(-BS) Model Number Indoor QOM PLA-A•24EA7 Outdoor Mial PUY-A24NHA7 PUY-A24NHA7-BS Package Dimensions W In. (mm) 40-15/16 D: In. (mm) 17-11/16 H: In. (mm) 40-11/16 Unit Weight Lbs. (kg) 151 (68) Package Weight Lbs. (kg) 176 (80) Outdoor Unit Operating Temperature Range Cooling Intake Air Temp (Maximum / Minimum) °F 115 DB / -20* DB Refrigerant Type R410A Charge Lbs; oz 7 lbs, 11 oz Piping Gas Pipe Size O.D. (Flared) In.(mm) 5/8 (15.88) Liquid Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Maximum Piping Length Ft. (m) 225 (69) Maximum Height Difference Ft. (m) 100 (30) Maximum Number of Bends 15 AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) *1 Cooling (Indoor //Outdoor) °F: • 80°F DB, 67°F WB // 95°F DB, 75°F WB Notes *Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -20°F -115°F. Refer to wind baffle documentation for further information. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic -Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • "Blue Fin" treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Notes: Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. DIMENSIONS: PLA-A24EA7 & PUY-A24NHA7 (-BS) PLA-A24EA7 _ MOMSRmRTRE OOr0.0ED MRIES FA M., E«�," F DRPE.FREEDED ORCQA,t� ""PTR. a�D MM. 011. NIPsYRRNPR,FROMT,ELW.e AMOR-..EREWED-YRE MINCE 14/.03£• LAKE WU TO 61.1,11IE ELECTRICAL WIRE LITRE MT FOR0.11.1030/1•10,XE Mr 19 AM TO KM:WEED TIEDRRIER. 7IIEOUIRFS 'V OR YORE SPACHSEPAVEN 'PROM MO CEDNa YRE NFE:11..,M. • TIE 61.410.1111.101.11E SNE TO NSIUYF ROE WREN. OTIERMSEaE ThEC N.TOFO Oft WPM WY0ttM. eR F[W IFS TIE WISE FE OR DROPLET OR d(ONET ONKNOI E68SN NFALLAVI EPVILI PACE RIME NOV TO IMF NOM AT RIME - .1 FORTIE NFTWRCR OR TME OPIRUE 17MENC'II MIER OR • . WTNUICYRNN C.FORTNI6ER TO SPECK NURNF. • 1NND Unit: inch (mm) Ma MUSS 00 110i11/0”1051.11. G.11114•041.11.1E CORM DWI MN IV* CCIMIEN FLLIDFOOTE Y.3.1001q FY PLARmrAT mHI:MUN iJ 001 901 SRN wih[ N.Mii-CfiA1 1031.01.01.4111 RODOWEIVI PNI 5 wRe-RDR Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. DIMENSIONS: PLA-A24EA7 & PUY-A24NHA7 (-BS) PUY-A24NHA7(-BS) 1 FREE SPACE (Aroudd the unit) The diagram belt shoes a lash on of p Ftehrlh i o1 petiole detailsare h sten hie habitation manuals etc. 2 SERVICE SPACE Dimensions ale/tate needed torenvies access are sham tithe below&wen 3 FOUNDATION BOLTS 4 PIPING4MRING DIRECTIONS Please sem to irk Derry Ronnie and Mag =medals with/Inundation (mom>)bp6. can De made len/6redios: (Bob and washers minas FROKRigt,Rea ed Behr. paanasMkwMs) Example of Notes Rear Ar Intake Hardie10 mo -•Refrigerant GAS pipe connection(FLARE) •15.118(EMP) - Relieved LIGUD pipe connedion(FLARE) •9.52(4 ), '1•-Indkatkin et STOP VALVE comedian hatica Air Intake Handle Jpr moving Piping knockout Hole Details .Poser sip* plies We Nehemiah Firle bat Unit: mm<in> QRerIntake bU ShapednBdtar.AalaNlYDOW • Seek hake for 950‘37-13/32, 32X12.11116s Faith Tended Connections ) Left— Power ssim�p�lyy wiring Refight -• Indoors tdoor wiring Service panel Handle for Pew mitring hie ('-enhndniy RiglCarrYg tide Set teemdvmdhtee . tMminafrgae orad, masite Anil (end u2c- FORM# PLA-A24EA7 / PUY-A24NHA7(-BS) - 201706 From Moine cover • Rear piping cover/ ArtMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Uaery 5mW aL ane1s.aw2ina:e Intertek Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. 3/1/2018 City of Tukwila Department of Community Development JARROD LONGMIRE 12646 INTERURBAN AVE S SEATTLE, WA 98168 RE: Permit No. M17-0138 SAHALE SNACKS 3411 S 120 PL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work;has begun for a period of 180 days. Your permit will expire on 4/21/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/21/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M17-0138 7-11 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PEFWHTCOORD COPY: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0138 DATE: 09/25/17 PROJECT NAME: SAHALE SNACKS SITE ADDRESS: 3411 S 120 PL - SUITE 100 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AT Building Division Public Works ❑ PQM IA °\\14 Fire Prevention Structural Planning Division ❑ Permit Coordinator • PRELIMINARY REVIEW: DATE: 09/26/17 Not Applicable ri Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/24/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 TCMS OF SEATTLE LLC Horne Espafiol Contact Safety & Health Claims & Insurance igilik Washington State Department of kj Labor & Industries Search L&I Page 1 of 2 A -L Index Help Aly L&1 Workplace Rights Trades.& Licensing TCMS OF SEATTLE LLC. Owner or tradesperson Principals MOORE, WILLIAM J, MANAGER Doing business as TCMS OF SEATTLE LLC WA UBI No. 602 845 504 Parent company MOORE HOLDING CORP P 0 BOX 11252 PORTLAND, OR 97211 570-928-5613 Business type Limited Liability Company Governing persons WILLIAM J MOORE THOMAS HERBURGER; DAVID RYAN; JANE RYAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ....................................................................... Meets current requirements. License specialties GENERAL License no. TCMSSSL905CB Effective — expiration 02/01/2010— 02/10/2018 Bond ......_...... DEVELOPERS SURETY & INDEM CO Bond account no. 269810C $12,000.00 Received by L&I Effective date 02/01/2010 01/27/2010 Expiration date Until Canceled Insurance Travelers Indemnity Company Th $1,000,000.00 Policy no. DTC06H357142IND167 Received by L&I Effective date 09/28/2017 10/01/2016 Expiration date 10/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings �s- 09q67-73 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602845504&LIC=TCMSSSL905CE&SAW= 10/23/2017 TCMS OF SEATTLE LLC No lawsuits against the bond or savings at its during the previous 6 year period. L&I Tax debts No L&l tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&1 Account ID 878,452-01 Doing business as TCMS OF SEATTLE LLC Estimated workers reported Quarter 2 of Year 2017 "21 to 30 Workers" L&I account contact T4 / NIKKI BUTLER (360)902-4918 - Email: BUTQ235@Ini.wa.gov Track this contractor Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ................. ..................................... No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602845504&LIC=TCMSSSL905CB&SAW= 10/23/2017