Permit M17-0162 - BDS H-10 BOEING COMPANY - HEAT PUMP, PIPING
BDS H-10 BOEING COMPANY 9725 E MARGINAL WAY S BLDG 9-008 M17-0162 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 5624201032 Permit Number: M17-0162 9725 E MARGINAL WAY S BLDG 9-008 Issue Date: 11/16/2017 Permit Expires On: 5/15/2018 Project Name: BDS H-10 BOEING COMPANY Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 CONNIE HARDIN 4600 S 134 PL , SEATTLE, WA, 98168 HOLADAY PARKS INC 4600 S 134 PL, SEATTLE, WA, 98168 HOLADP1379NO 111 Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2019 DESCRIPTION OF WORK: INSTALL HEAT PUMP, ASSOCIATED PIPING Valuation of Work: $7,500.00 Type of Work: Fuel type: Fees Collected: $313.23 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Date: 4//G47 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local.laws regolating1construction or the performance of work. I am authorized to sign and obtain this developed �':`rPni. angee to the co .'itions attached to this permit. Signature: Print Name: C0O1./1 r L4Cts �t Date: (H (0-1 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 12: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 13: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 14: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 15: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 16: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 17: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 18: ***MECHANICAL PERMIT CONDITIONS*** 19: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 20: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL ybW3 Fits 14 -to CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov (2 Mechanical Permit No. �U i'�� IJ v Project No: . Date, Application Accepted: �� s I'I Date Application Expires: (For'o ce u only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION .Site Address: q &• Lo 4/1 Q A. Tenant Name: 11).S 4`1 b po_ King Co Assessor's Tax No.: SI 2. q 0 /0 32. Suite Number: Floor: New Tenant: 0 Yes 1171:No CONTACT PERSON- person receiving all project communication Name: • AAt•R, '[ la,-d1I Address: t 160 s rst.0'�1 2 `•lkarrLe City• State: , .c \Zip:ni1j_v Phone 6asp, 4 Fax:2662U G e7a00o Email:eNnel :tie L D okoat.t.4 su.r6•040w ., '. ECHANICAL CONTRACTOR INFORMATION Company Name:1 LI parks Address:4600 S i 3 n n City:` State: ZipsT .CoY Phone�� as0 cis".3d Fax:9 au.$ g ?DO Contr Reg No.: Exp Date: a " is 0bP ao s 3?a�iA Tukwila Business License No.: Valuation of project (contractor's bid price): $ 1S-0° n n ` e.ld -p +p as50C;W 144,1. Describe the scope of work in detail: Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric 0 Gas 0 Other: H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 14-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor fumace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 1 <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfin Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 1 Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) ae 1 Boiler/Compressor Qtr 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: — Date: 1 1 -- Print Print Name: &f h ►t 1AaX1 Lit Day Telephone: b% Ste Ws 36 Mailing Address: —1 IbOO 5 1 t*' 61. l / ($ ' City State Zip H:\Applications\Forms•Applications On Linc\201 6 Applications \Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R12731 DESCRIPTIONS ( PermitTRAK ACCOUNT QUANTITY PAID $313.23 M17-0162 Address: 9725 E MARGINAL WAY S BLDG 9-008 Apn: 5624201032 $313.23 Credit Card Fee $9.12 Credit Card Fee R000.369.908.00.00 0.00 $9.12 MECHANICAL $292.41 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $200.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $58.48 TECHNOLOGY FEE $11.70 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12731 R000.322.900.04.00 0.00 $11.70 $313.23 Date Paid: Monday, November 06, 2017 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 07368G Printed: Monday, November 06, 2017 12:11 PM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 Mil-o/!2a (206) 431-3670 Project: /30i/NG- pDs ft -16/WO/ Type of Inspection: ivtgCIl4/v, L Address: 9'725 g; filer401.--OH Date Called: Olio- n / H sU iffi77.1N Special Instructions: ?Tlvh2D6-`t4$-!Q3�%R Date Wanted: L-2 5s-1,63 a.m P.m. Requester: O K Phone No: NA LL &Approved per applicable codes. E Corrections required prior to approval. COMMENTS: ok (, -/1 dv K cl+ri liCif 4 -- PK Olio- n / H sU iffi77.1N O K /4PSC HrgAirc l z_ NA LL Inspector: ‘J:K Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0162 DATE: 11/07/17 PROJECT NAME: BDS H-10 BOEING #9-08 SITE ADDRESS: 9725 E MARGINAL WAY S #9-08 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: SActiv c 11-9 -7 - Building Division Public Works ETA ;irk�1�� 11-13-1 Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWERcb INITIALS: DATE: 11/07/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/05/17 Approved ❑ Approved with Conditions L Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER06 INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC Home Espaiiol Contact. Safety & Health Claims & Insurance CoWashington State Department of Labor & industries Page 1 of 3 Search L&I A -Z Index Help My I&1 Workplace Rights Trades & Licensing HOLADAY PARKS INC Owner or tradesperson BECK, DAVID CARL Principals BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUIT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) WA UBI No. 578 004 089 4600 S 134TH PL SEATTLE, WA 98168 206-248-9700 KING County Business type Corporation License Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 11/16/2017 HOLADAY PARKS INC Verify the contractor's active registration / license Construction Contractor License specialties GENERAL License no. HOLADPI379NO Effective — expiration 01/21/1983— 09/03/2019 Bond LIBERTY MUTUAL INS CO Bond account no. 23000452 , tification (depending on trade) and any past violations. Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/23/2002 09/01/2002 Expiration date Until Canceled Insurance Charter Oak Fire Ins Co Policy no. DTCO1F465357C0F17 $1,000,000.00 Received by L&I Effective date 10/31/2017 11/01/2017 Expiration date 11/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. LW Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 177,231-00 Doing business as HOLADAY PARKS INC Estimated workers reported Quarter 3 of Year 2017 "Greater than 100 Workers" L&I account contact T4 / CASSANDRA SMITH (360)902-5632 - Email: SMCA235©Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/22/2016 Inspection no. No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 11/16/2017 PROJECT NAME: -+hnOl L) S' S i n SITE ADDRESS: lice � ?"1"-lk PERMIT NO: M O ORIGINAL ISSUE DATE: if).-.( REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF /j f IALS - l ('i �- Summary of Revision: A , , ` n \ A_ ILA r i e Aar- ww,Mo— e4/11-- Received by: L � , `;�', _T%. AI REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I 1 1 a Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: r/6 C1_31Chl Project Address: \ \ 6 RivioiQ_r Pox erhoory-fhone Contact Person: - U'V� e-� l Number: (3f( S S 6 Summary of Revision: )( E>c,4 in * Pkow, RECEIVED CITY OF TUKWILA JAN 1 6 2018 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including de of of revision C Received at the City of Tukwila Permit -Center by: Entered in TRAKiT on 1 ssE ( `( V W:'Permit Center (Brenda)\Forms\Permit Center Documents (Word)\Revision Submittal Form.doc Revised: August 2015 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: //g// Y Plan Check/Permit Number: M 17-0184 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Innovasian Cuisine Project Address: 116 Andover Park E Contact Person: , f�an /0%71 4 Phone Number: 6 ??3 r/? 5 Summary of Revision: RECEIVED CITY OF TUKWILA 0 8 2018 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date o revi ipn Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: SKILFAB SHEET METAL CO Horne Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 A -Z Index Help My L8:I Workplace Rights Trades & Licensing SKILFAB SHEET METAL CO Owner or tradesperson Principals MCNEELY, DANIEL ROBERT, PRESIDENT MCNEELY, MARIANNE LUCILE, SECRETARY MCNEELY, DANIEL S (End: 01/01/1980) STEWART, BRUCE (End: 01/01/1980) MCNEELY, ROBERT SAMUEL, VICE PRESIDENT (End: 01/18/2017) NEFF, SUSAN M (End: 02/15/2011) Doing business as SKILFAB SHEET METAL CO WA UBI No. 600 555 086 8300 Railroad Ave SE #1775 SNOQUALMIE, WA 98065 425-831-5555 KING County Business type Corporation Governing persons DANIEL R MCNEELY ROBERT S MCNEELY; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties METAL FABRICATION License no. SKILFSM169RE Effective — expiration 12/05/1984— 01/22/2019 Bond CBIC Bond account no. SA5760 $6,000.00 Received by L&I Effective date 10/15/2001 12/03/2001 Expiration date Until Canceled Insurance Hallmark Insurance Company $1,000,000.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600555086&LIC=SKILFSM169RE&SAW= 1/12/2018 SKILFAB SHEET METAL CO Policy no. 44CL495091 Received by L&I Effective date 0810112017 08/01/2017 Expiration date 08/01/2018 Hartford Casualty Ins Co Policy no. 52SBAVY4480 $1,000,000.00 Received by L&I Effective date 07/31/2017 08/01/2017 Expiration date 08/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. LW Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 480,131-00 Account is current. Doing business as SKILFAB INDUSTRIES INCORPORATE Estimated workers reported Quarter 3 of Year 2017 "7 to 10 Workers" L&I account contact T4 / STEPHEN TASSONI (360)902-4819 - Email: TASS235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600555086&LIC=SKILFSM169RE&SAW= 1/12/2018 v C T" PSA 7-127 KING COUNTY AIRPORT OFFICE .CENTER (FM) PROJECT SITE FROM DOWNTOWN SEATTLE ri 14-01 900 AIR MUSEUM BOEING FIELD rn -o 95 0 -11 EXIT 158 EXIT 157 599 TUKWILA EAST MARGINAL WAY 99 CORPORATE PARK FROM SEATTLE -TACOMA AIRPORT DEVELOPvE\ TAL CE\TE FROM KENT & AUBURN 900 NO SCALE BO 9/25 PORTIO \ S W D AS NA,. of SPCTO LLAV1- T1- V U v PHD OP D \ ARG AS U TOW\S A\ DARCFL \ VB AREA NA D 3UILD1\G ADERESS: 9725 EAST VAGI\AL WAY SOUTH TU<WILA, WASHI\GTO\ PROJECT SITE 3UILIJI\G 9-08 LOCATIO\ NO SCALE 9 A 23 \C CO R 562/ A 08 0\ \OR \TV, WAS 20-0990 9 U 98 SO 08 A\CH II\GTO\ R FAST, CO3E SMVARV 9-08 SUMMARY BUILDING CODE OCCUPANCY GROUP CONSTRUCTION TYPE LOCATION ON PROPERTY FLOOR AREA (ACTUAL): BUIDLING FOOTPRINT BUILDING GROSS 1ST FLOOR 2ND FLOOR 3RD FLOOR 4TH FLOOR 5TH FLOOR PENTHOUSE BUIDLING HEIGHT STORIES OCCUPANT LOAD: OFFICE @ 1 TO 100SF MECH/STORAGE © 1 TO 300SF OTHER © 1 TO 100SF HANDICAPPED REQUIREMENTS FIRE PROTECTIONS SEPARATION EXTERIOR WALL (NON–BEARING) INTERIOR WALLS (NON–BEARING) INTERIOR WALLS (BEARING) STRUCTURAL FRAME FLOORS STAIR ENCLOSURES SHAFT ENCLOSURES ELEVATOR SHAFT CORRIDORS ROOF ROOFING CONSTRUCTION SEISMIC ZONE DESIGN LOADS: ROOF – SNOW LIVE FLOOR OFFICE (LIVE) DEAD MECH & STORAGE STAIRS & CORRIDOR WIND SCOPE OF WORK: 2015 INTERNATIONAL BUILDING CODE B BUSINESS (GROUP B, PROFESSIONAL SERVICES) TYPE II–A (FORMERLY II–FR) MINIMUM 60 FT. ALL SIDES 50,207 SF (37,500SF X 2=75,000SF ALLOWABLE W/SPRINK 253,832 SF INCR.) 50,012 SF 50,207 SF 50,207 SF 50,207 SF 50,207 SF 2,992 SF 84'-1" ROOF PARAPET, 95'-3" PENTHOUSE PARAPET, 85' ALLOW 5 (5 ALLOW PER 97UBC, 5 +1=6 SPRINKLER ADD ALLOWABLE) 1ST FLR © 340 2ND, 3RD, 4TH, 5TH © 419 EACH BUILDING TOTAL = 2016 BARRIER FREE FULLY AUTOMATIC THROUGH–OUT F/S CLASS 1 1 HOUR UNPROTECTED (UBC & IBC) 1 HR 97UBC & 2003 IBC 2 HR 97 UBC, 1 HR 2003 IBC 2 HR 97 UBC, 1 HR 2003 IBC 2 HR 97 UBC, 1 HR 2003 IBC 2 HR 97 UBC & 2003 IBC 2 HR 97 UBC & 2003 IBC 2 HR 97 UBC & 2003 IBC 1 HR 97 UBC & 2003 IBC 1 HR 97 UBC & 2003 IBC FIRE RETARDANT: CLASS A (FM CLASS 1) CATEGORY 'D' 25 PSF 20 PSF 100 PSF 20 PSF (PARTITION) 125 PSF 100 PSF 110 MPH ARCHITECT'S INTENT: FOR 2015 IBC WORK DESIGN WILL MAINTAIN EXISTING LIKE KIND MATERIALS AND ASSEMBLIES PER 97 UBC REQUIREMENTS. RECONFIGURE EXISTING BUILDING AREA TO ACCOMMODATE NEW LAB FUNCTIONS. WORK INCLUDES INSTALLING PROJECTION SCREENS, FURNITURE, (1) INTERIOR WALL AND DOOR, ALONG WITH ASSOCIATED MECHANICAL AND ELECTRICAL. SEPARATE PERMIT REQUIRED FOR: 0 Mechanic L1lectrrc l Q'Plumbing was Piping City of Tukwila BUILDING DIVISION REVISIONS No changes sha11 he made to the scope of work withOI.iF prior approval of i ult ii!a Building Division. NM : Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No, • Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved • d +nr• nditiorts i; knowledgecf: Date: u --I -D City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED NOV 14 2011 %A--5 City of T uktivla BUIL©t /*MVP ISSUE FOR CONSTRUCTION OCTOBER 27, 2017 RECEIVED •p r)r: i f; i ._ KAI it6Is PERMIT CENTER SITTS & HILL ENGINEERS, INC. CML ■ STRUCTURAL • SURVEYING 4815 CENTER STREET 1 TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sitts-hill-engineers.com/ Project No.: 18019 Project Mgr.: BKL Proj. Engineer: DCB Proj. Drafter: SLM SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE H10 REV 1 34355 SITTS BKL 10.12.17 Q,�BOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Leslie ENGINEER D. Boileau CHECKED B. Leslie APPROVED APPROVED DATE 09.08.17 09.08.17 09.08.17 09.08.17 SUBTITLE TITLE ARCHITECTURAL COVER SHEET H10REV 1 BUILDING 09-08 DEV. CENTER, WA CURRENT REVISION SYMBOL 34355 DATE 10.27.17 SHEET AO JOB NO. 34355 COMP NO. DWG NO. 09-008–AO 10:59:12 PM SMCCARTHY: 8/16/2017 \DFX OF DRAW 1 \GS INCLUDED IN SET NO. SHEET NO. DRAWING TITLE REV DATE DRAWING ACHITECTUAL 09-08–AO AO COVER SHEET 10.27.17 — 09-08–AI Al GENERAL ARCHITECTURAL NOTES 10.27.17 — 09-08–IA3 1A3 COMPOSITE FIRST FLOOR PLAN -- 10.27,17 09-08-1A450 IA450 ENLARGED FIRST FLOOR PLAN 10.27.17 — 09-08–IA450R IA450R ENLARGED FIRST FLOOR PLAN – REMOVAL -- 10,27.17 09-08–A500 A500 MISC SECTIONS AND DETAILS -- 10.27.17 VECHA\ICAL 09-008–M4 M4 EQUIPMENT SCHEDULES G 10.27,17. 09-08–IMI0 IMIO HVAC PLAN B 10.27.17 09-08–IMIOR IMIOR HVAC PLAN – REMOVAL A 10,27.17 09-08-1M60 IM60 FIRST FLOOR PIPING PLAN A 10.27.17 09-008–IM260 IM260 FIRE PROTECTION IST FLOOR PLAN A 10.27,17 ELECTRICAL ID 09-08–IEIOR IEIOR FIRST FLOOR LIGHTING PLAN – REMOVAL A 10.27.17 09-08–IE10 IEIO FIRST FLOOR LIGHTING PLAN A 10.27.17 09-08-1E60 1E60 208Y/120V POWER PLAN C 10.27.17 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 14 2011 %A--5 City of T uktivla BUIL©t /*MVP ISSUE FOR CONSTRUCTION OCTOBER 27, 2017 RECEIVED •p r)r: i f; i ._ KAI it6Is PERMIT CENTER SITTS & HILL ENGINEERS, INC. CML ■ STRUCTURAL • SURVEYING 4815 CENTER STREET 1 TACOMA, WA. 98409 PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sitts-hill-engineers.com/ Project No.: 18019 Project Mgr.: BKL Proj. Engineer: DCB Proj. Drafter: SLM SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE H10 REV 1 34355 SITTS BKL 10.12.17 Q,�BOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. McCarthy CHECKED B. Leslie ENGINEER D. Boileau CHECKED B. Leslie APPROVED APPROVED DATE 09.08.17 09.08.17 09.08.17 09.08.17 SUBTITLE TITLE ARCHITECTURAL COVER SHEET H10REV 1 BUILDING 09-08 DEV. CENTER, WA CURRENT REVISION SYMBOL 34355 DATE 10.27.17 SHEET AO JOB NO. 34355 COMP NO. DWG NO. 09-008–AO 10:59:12 PM SMCCARTHY: 8/16/2017 HEAT PUMP (HP) SCHEDULE MARK NUMBER FAN PERFORMANCE FILTER (SPECIAL DETACHED) AIR CONNECTIONS AT FILTER BOX WATER FLOW GRISWOLD FLAW CONTROL ASS Y COOLING PERFORMANCE HEATING PERFORMANCE MAXIMUM SET CFM REMARKS MAX. CFM EXT. STATIC IN. Wq. MOTOR FLA SIZE FACE VEL FPM MAX -FINAL SP IN WG CFM SIZE / OTHER GPM MAX. PRESS. DROP CONDENSER FT. WG HOSE SIZE HOSE LENGTH PSI RANGE FLOW RATE GPM 24x24 HOSE SET P/N EAT °F DB/WB ° EWT F TOTAL MBH SENSIBLE MBH HT. REJECT MBH POWER INPUT KW LAT °F DB EWT °F TOTAL HEAT MBH HEAT ABSORBED MBH POWER INPUT KW MANU./MODEL SIZE QUANTITY HP -1 486 0.5 0.86 1-24x24 120 0.3 75/6"0 PLENUM 3.0 3.4 1/2" 36" 2-32 3 140 K10-2DS 80/67 85 14.3 10.3 19.1 1.45 65 65 17.6 12.6 1.49 (4) MACQUAY/CCH 15A 77 EGG CRATE CEILING SUPPLY GRILL HP -2 955 0.5 1.0 1-24x24 240 0.3 145/7"0 PLENUM 6.1 4.6 3/4" 36" 2-32 6 .080 K10-2FS 80/67 85 29.3 21.8 39.5 2.99 65 65 37.0 26.2 3.19 (1) MACQUAY/CCH 30A 191 WHITE HP -3 1275 0.5 1.8 1-24x24 320 0.3 190/8"0 (5) PLENUM 8.6 10.7 3/4" 36" 2-32 9 TITUS SERIES 270 K10-2FS 80/67 85 41.7 31.4 55.8 4.1 65 65 54.0 39.3 4.30 (1) MACQUAY/CCH 42A 44 HP2B16 HP -4 1940 0.5 2.6 2-24x24 240 0.3 290/0 PLENUM 12.8 9.8 1" 36" 2-32 13 EXHAUST GRILL K10-2HS 80/67 85 61.3 46.7 82.7 6.3 65 65 60.1 43.0 5.02 (1) MACQUAY/CCH 60A 9 .065 HP -5 800 0.72 2.4 1-24x18 240 0.3 160/8"0 PLENUM 6.2 11.08 1" 36" 2-32 6 WHITE K36-2HS 80/67 85 24.4 17.5 30,9 - 65 65 28.1 21.5 HP5A17 MACQUAY/WCCW 24 1 (1),(2),(3),(4) NOTES (1) R -410A REFRIGERANT (2) 460/3PH, 5.3 MCA (3) 14.7 EER (4) 4.23 COP AIR DIFFUSER / REGISTER / GRILL SCHEDULE MARK NUMBER TYPE MATERIAL FINISH FACE SIZE INCHES INLET/NECK SIZE INCHES MAXIMUM NOISE COEFFICIENT MAXIMUM TP INCH WG MAXIMUM SET CFM REMARKS CD -1 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 60 33 .060 190 KRUEGER 6404F23 CD -2 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 80 33 .110 275 KRUEGER 6404F23 CD -3 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 100 36 .130 425 KRUEGER 6404F23 CD -4 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 120 36 .127 550 KRUEGER 6404F23 CD -5 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 140 48 .240 950 KRUEGER 6404F23 RG -1 EGG CRATE CEILING RETURN GRILL STEEL WHITE 24x24 24x24 29 .150 800 KRUEGER EGC-JNSF SG -1 EGG CRATE CEILING SUPPLY GRILL STEEL WHITE 24x24 22x22 --- .150 2900 KRUEGER EGC-JNSF SG -2 PERFORATED CEILING SUPPLY GRILL STEEL WHITE 24x24 60 34 .080 220 KRUEGER 6590F23 SG -3 PERFORATED CEILING SUPPLY GRILL STEEL WHITE 24x24 80 43 .200 380 KRUEGER 6590F23 SG -4 PERFORATED CEILING SUPPLY GRILL STEEL WHITE 24x24 100 44 .210 540 KRUEGER 6590F23 SG -5 SUPPLY GRILL STEEL WHITE 16x10 HP4B11 25 .120 720 TITUS SERIES 270 SG -6 SUPPLY GRILL STEEL WHITE 12x6 HP3B11 23 .120 280 TITUS SERIES 270 SG -7 SUPPLY GRILL STEEL WHITE 16x6 HP2B16 23 .100 400 TITUS SERIES 270 SG -8 SUPPLY GRILL STEEL WHITE 30x18 HP1B15 21 .100 2000 TITUS SERIES 270 EG -1 EXHAUST GRILL STEEL WHITE 14x8 HP5A5 29 .150 450 TITUS CORE 8F EG -2 EXHAUST GRILL STEEL WHITE 6x5 HP5A9 26 .065 50 TITUS CORE 23 EG -3 EXHAUST GRILL STEEL WHITE 8x6 HP5A15 29 .100 130 TITUS CORE 8F EG -4 EXHAUST GRILL STEEL WHITE 12x8 HP5A16 26 .040 280 TITUS CORE 23 EG -5 EXHAUST GRILL STEEL WHITE 18x16 HP5A17 32 .110 720 TITUS CORE 23 EG -6 EXHAUST GRILL STEEL WHITE 24x16 HP5A18 33 .180 1200 TITUS CORE 23 EG -7 PREFORATED CEILING EXH GRILL STEEL WHITE 24x24 12x12 29 .150 600 TITUS 8F TYPE 3 SOUND ATTENUATOR (SA) SCHEDULE MARK NUMBER HEAT PUMP ID NUMBERS UNIT WIDTH X HEIGHT INCHES HP1 MAX FV FPM AIR QUANTITYOCTAVE CFM HP2 10-12 W HERTZ REMARKS HP3 HP4 HP5 HP1A4A HP4C2 HP1A9 HP2B4 HP3A9 HP4A9 MEESE HP1A19 HP5C15 HP1B5A HP1B5A HP1A6A HP4C10 HP1A10 HP2B5 HP3Al2 HP4Al2 HP5B6 HP1C5 HP5C14 HP2E16 HP3A7 HP1A8 HP4C12 HP1A13 HP2B7 HP3A18 HP4A15 HP5B11 HP1C9 HP5C13 HP2E17 HP4C8 HP1B4 HP4C17 HP1A15 HP2B8 HP3B4 HP4A17 HP5B12 HP1C14 12x18 HP3C18 550 HP1B8 HP4C18 HP1A17 HP2B9 HP3B5 HP4B4 HP5B15 HP1D6 28 HP4A10 IAC TYPE S HP1B11 HP4D17 HP1B3 HP2B10 HP3B6 HP4B5 HP5B18 HP1D14 12 HP4A11 28 HP1B18 HP4E1 HP1B6 HP2B11 HP3B7 HP4B6 HP5C2 HP1E13 .10 HP4B10 500 HP1B19 HP4F1 HP1B9 HP2B12 HP3B8 HP4B7 HP5C12 HP1E17 17 HP4C11 SA -6 HP1C3 HP4F3 HP1610 HP2B13 HP3B9 HP4B8 HP5C15 HP2C6 16 HP4D11 35 HP1C17 HP4F10 HP1B12 HP2B14 HP3B10 HP4B11 HP5C19 HP2C14 550 HP5B10 +1000 HP1D1 HP4F11 HP1B13 HP2B15 HP3B11 HP4B12 HP5D11 HP2D6 IAC TYPE S HP2C18 HP1D7 HP4F14 HP1B14 HP2B16 HP3B12 HP4B13 HP5D12 HP2D9 HP1D16 HP4F16 HP1B15 HP2B17 HP3B16 HP4B14 HP5E1 HP2D14 HP1F1 HP5A5 HP1B16 HP2B18 HP3B17 HP4B15 HP5E2 HP3A14 HP1F10 HP5A9 HP1B17 HP2B19 HP3B18 HP4B16 HP5E7 HP3A15 HP1F17 HP5A15 HP1C3 HP2C2 HP3B19 HP4B17 HP5E10 HP3B15 HP2A4 HP5A16 HP1C8 HP2C8 HP3C3 HP4B18 HP5E11 HP3C6 HP2A9 HP5A17 HP1C12 HP2C11 HP3C8 HP4B19 HP5E12 HP3C9 HP2A15 HP5A18 HP1 D11 HP2C12 • HP3C11 HP4C3 HP5E13 =-_�-- HP2A19 HP5A19 HP1E1 HP2E2 HP3C12 HP4E2 HP5E17 HP3D6 HP2B6 HP5B5 HP1E2 HP2E3 HP3D2 HP4E3 HP5F6 HP3D14 HP2C3 HP5B8 HP1E3 HP2E4 HP3E1 HP4E4 HP5F11 HP3E2 HP2C17 HP5B19 HP1 E4 HP2E5 HP3E3 HP4E5 HP5F13 HP4C6 HP2D1 HP5C3 HP1E5 HP2E6 HP3E4 HP4E6 HP5F16 HP4C14 HP2F3 HP5C9 HP1E6 HP2E7 HP3E5 HP4E7 HP5B13 HP4D6 HP2F7 HP5C17 HP1E8 HP2E8 HP3E6 HP4E8 HP4D9 HP2F9 HP5D3 HP1E11 HP2E9 HP3E7 HP4E9 HP4D14 HP2F16 HP5D15 HP1 E14 HP2E10 HP3E8 HP4E10 HP4E16 HP3A3 HP5E3 HP1 E15 HP2E11 HP3E9 HP4E11 HP5A3 HP3A19 HP5E5 HP1 F3 HP2E12 HP3E10 HP4E12 HP5B4 HP3B13 HP5E8 HP1F4 HP2E13 HP3E11 HP4E13 HP5B7 HP3B14 HP5E15 HP1 F5 HP2E14 HP3E12 HP4E14 HP5B9 HP3C2 HP5F1 HP1F6 HP2E15 HP3E13 HP4E15 HP5C6 HP3C17 HP5F4 HP1 F7 HP2F1 HP3E14 HP4F5 HP5C14 HP3F9 HP5F8 HP1F12 HP2F2 HP3E15 HP4F7 HP5C18 HP3F10 HP5F17 HP1F12 HP2F5 HP3E16 HP4F13 HP5D6 HP3F11 -' F : HP1 F14 HP2F12 HP3F1 HP4F17 HP5D9 HP3F16 HP1P3 HP2A3 HP2F14 HP3F3 HP5A4 HP5D14 HP3F17 HP2A6 HP2F15 HP3F6 HP5A7 HP5E4 HP4A19 HP2A9 HP3A4 HP3F14 HP5A10 HP5E6 HP4B3 HP2A13 HP3A7 HP4A4 HP5Al2 HP5E9 HP4B9 HP2A17 HP3A8 HP4A6 HP5E14 SOUND ATTENUATOR (SA) SCHEDULE MARK NUMBER LENGTH FEET UNIT WIDTH X HEIGHT INCHES MAXIMUM PD IN/H20 MAX FV FPM AIR QUANTITYOCTAVE CFM MINIMUM REQUIRED ACOUSTIC RATING dB RE BAND CEJ�ITER FREQUENCY 10-12 W HERTZ REMARKS RATING 63 125 250 500 1000 2000 4000 8000 SA -1 3 12x36 .11 550 1650 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA -2 3 12x24 .10 550 1000 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA -3 3 12x18 .10 550 750 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA -4 3 12x42 .11 600 2000 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA -5 3 6x24 .10 550 500 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA -6 3 12x12 .10 550 500 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA -7 3 6x12 .10 550 450 +1000 7 12 16 28 35 35 28 17 IAC TYPE S ID NUMBER EXAMPLE: HP2D16 PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED NOTES: (1.) 460V/30/60Hz (2. 208V/30/60Hz 3.) 115V/1 0/60Hz (4.) 208V/1 0/60Hz FSi consulting engineers Seattle, Washington Solutions 8c Service 1 COLUMN LOCATION FLOOR HEAT PUMP CONSTRUCTION NOTES -0144-if ISSUED FOR CONSTRUCTION OCTOBER 27, 2017 RECEIVED CITY OF TUKWILA NOV 0 6 2017 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE ;.. APPROVED NOV 14 217 City of Tukwila BLUING 0[VISIQN SYM A B REVISION BY APPROVED DATE C D E RECORD DRAWINGS UPDATE EQUIPMENT LIST REPLACE HEAT PUMP 160082-00 JSF MIC VTC PROJECT J#701437-00 BLDGS 9-08 & 9-96 BR&T BELLEVUE RELOCATION W1901252 MJC SR DMV C. HARRAH SAZAN/SS KMR/DS RS/EJC RS/EJC RWS 10.1.90 3.19.94 SYM F G REVISION RECORD DRAWING BDS LAB PACKAGES 1-5 - H10 - BOX 10 34355 BY SAZAN/SL FSi APPROVED DATE AWL 12.09.13 10.27.17 7.29.96 2.20.01 08.06.13 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED BY DEPT. APPROVED 10.27.17 SIAM DATE DRAWN P. TRACEY DATE CHECKED R. MURRAY ENGINEER W. HENCKEL CHECKED W. HENCKEL APPROVED K. RAMSEY SUBTITLE EQUIPMENT SCHEDULES CURRENT REVISION SYMBOL 34355 G DATE 10.27.17 APPROVED D. SEPTELKA 10.1.90 TITLE BDS LAB PACKAGES 1-5 - H10 - BOX 10, T PROP MECHANICAL MASTER BUILDING 09-008 COL. N/A DEV. CENTER, WA SHEET M4 JOB NO. COMP NO. DWG NO. 09-008-M4 CO \ST J CTIO\ \OYES: PROVIDE HEAT PUMP, DAIKIN MODEL WCCW24. COORDINATE EQUIPMENT PROCUREMENT WITH BOEING SURPLUS. CONTRACTOR TO PROVIDE REPLACEMENT HEAT PUMP TO BOEING SURPLUS. INTEGRATE HEAT PUMP INTO EXISTING BUILDING CONTROL SYSTEM. PROVIDE FIRE DAMPER. PROVIDE THERMOSTAT AND MOUNT 4' A.F.F. AT LOCATION SHOWN. RELOCATE THERMOSTAT TO LOCATION SHOWN. MOUNT 4' AF.F. R1A> 7 1M13,1M14 M507 CHNG TO 12/12 THRU WALL GE\EAL \ITES 1. TYPICAL HEAT PUMP NUMBERING SYSTEM; a EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE, SEE SCHEDULE ON SHEET M4, SYMBOL FOR (RG) TYPICAL. 12"W X 12"H DUCT SILENCER, IAC 10TLMS 10 FEET LONG. DUCT ACCESS DOOR FOR THE FIRE DAMPER. 9x9 FIRE DAMPER, GREENHECK DFD -150 TYPE -A, 165°F { (v) 200 EVAP. { 12/10 HP1A4A, \HP2/ 290 100 V) LID 2 SF) 220 DA 60 19. ClJ <c3D> TYP OF 6 125 )NAM• 125 C5 Ma I 2 HP1C3 \HP2/ 16/10 150 CD 1 2S HP1D1 \HP1/ 225 HP1E1 \HP2/ N (7) 150 1 SF 4 (r) 6/10 150 22`HP1F1 5 `PV 150 war - for 1,11Psil 8/8 \P1 B4 300 Al HP1% ©1 SF 20/12 2200 24/10 290 24/ 20/12 ABOVE 20-i'12 Aft { 1 CD 2 6/8 3 ` 100/C1D\ �P1C HPlf FB, FD 190 IT 1 SF r { x-2900 0,3 430 ECD. 3 3 <C3 r4 430 HP1E3 ;"0 \HP2/ 12/10 8/10 10/10 14/10 20/12 P1BA� 290 �HP4� 290 71 5 CIJ 1 N‘ ( 0CD 1 HP1F4 415 \HP2/ 80 14/10 '01 415 HP1F� \HP2/ 2 80 HP1E4\ 1 0 150 50 HP1E� \HP2/—' 4/10 60 (CD 3 )TYP OF 3 11111 ( C2D (C2D) FI 20/16 0 6 SF 150 8/12 FD FD FD 60 AC1D7A 275 60 360 10/10 Ng gig I=1 gill MI gl=1111=1 lig 12 1111 CM Illi= MATCH LINE (FOR CONTINUATION SEE SHEET 1M13) RST FLOOR HVAC PLA\ 2 /16 24/12 1M14 60 4/10 FD 02(C3 ,275 HP1F7 \HP2/ 1 44/16 PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED 20/12 AFSD TYPICAL 6 PL AFSD2 34/22 AFSD2 30/30 34/14 50/60 AFSD2 16/12 44/16 2M13 20/16 20/16 AFSD FSD 1M14 M520 16/12 FD 20/16 AFSD A IM MATCH LINE (FOR CONTINUATION SEE SHEET 1M13) PARTIAL FIRST FLOOR 0 FSi consulting engineers Seattle, Washington Solutions & Service LEGEND: VAC PLA\ 11E1 INN MEIN EXISTING WALLS NEW FULL -HEIGHT PARTITION DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AND STC 45 PARTITION STC 45 PARTITION STC 50 PARTITION FD FIRE DAMPER 5/4 REVIEWED FOR CODE COMPLIANCE APP7ED NOV 14- 2017 d Tukwila RECEIVED CITY OF TUKWILA PERMIT CENTER ISSUED FOR CONSTRUCTION Mil #0 I OCTOBER 27, 2017 SYM A REVISION BY SAP ROOM RECONFIGURE BDS LAB PACKAGES 1-5 - H10 - BOX 10 34355 M.WONG FSi APPROVED RWS AWL DATE SYM REVISION BY APPROVED DATE 03.02.07 10.27.17 si?_i__Am,Enzw ® MMID ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN D. WILLIAMS CHECKED M. CAUNITIS DATE 10.01.90 ENGINEER M. CAUNITIS CHECKED W. HENCKEL APPROVED K. RAMSEY APPROVED D. SEPTAELKA 10.01.90 10.01.90 10.01.90 10.01.90 SUBTITLE TITLE HVAC PLAN BDS LAB PACKAGES 1-5 - H10 - BOX 10 MECHANICAL MASTER BUILDING 9-08.1 COL. A -F/1-7 DEV. CENTER, WA CURRENT REVISION SYMBOL 34355 3 DATE 10.27.17 SHEET 1 M 1 0 JOB NO. 1M13,1M141 CHNG TO 12 THRU WALL v EVOVAL \OTES. GE\EAE \ETES REMOVE DUCT AND CAP. DIFFUSERS TO REMAIN. 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL, EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. a SYMBOL FOR (RG) TYPICAL. CD IIW 12"W X 12"H DUCT SILENCER, IAC 10TLMS 10 FEET LONG. , 1 1, © DUCT ACCESS DOOR FOR THE FIRE DAMPER. © 9x9 FIRE DAMPER, GREENHECK DFD -150 TYPE -A, 165°F \ \ 350 \ CD �125 (i) CD 'w, tr'I CD t I 1 150 1 0 350 150E , 7 4 50 o 5 1 SF CD .--' 1 111) II 1 )8 2 SF _.� SF _ 4, ---, 125 HPlEI \HP2/ 6/10 150 \ I ( HP1D1 V �_ HP1F1 .� HP1� 225 \ HP1 � � <GB> 225 1 A 1D 190 190 CD A _/2900 .►2 CD CD 150 �� \ �� t1 P1C3 2 ` _ HP El 2 / P2 2 x'25 CD1/10 0`�)90 7\HP2/ 8/10 /10 \'� HP1F3 CD I 1 = t% 1-� •.•- CD r F� ) , 24/1E \HP2/ 2 --- N CD i 2 10so ; 190 190 gi 00 2 ® EVAP, f 2506 ]FDI W' N 14 12 \ ❑-2900 <GB) 2 430 <GB) 430 3 200 � © F�.- v CD 3 \HP2/ - HP E1 r� , 100 N 75 o 3 ' 50 \ 6/8 FD \HP2/ - - 6 FD �� t..� 12/10 250 , HP Cl 3 r--. (CID 8/10 12/10 \ ��� (CI 8/8 \HPI/ cD D _ FD r ' . HP1B4 300 'GI o 1 D. L-1 L �HP1Y 30/12 �''� \�1 (CID) —� — ,.•._ ----� 1 1 SF 10/10 14/10 SG _ 0 CD CR1Ab HP1A4A, o �- 2 SF \ 1 SF HP Fl 4 750\HP2/(' ' .� , 2200 CD ?900 = 1 415 \HP2� OOA6020/12 c�20 ) `�� 80 290 24/10 ``-A,- AM15 CD �; L 100( _ ill 290 �' ©o\%,ri \1507 1 290 (c3D 290.:1SG 10/10 14/10 24/ j," 1 \ 20/12 MI1 ► TYP OF 6 q ABOVE HP1E4 ` E 150 ,0 PP00 I i 20/12 EA \HP2/� 29010x) ' �'_,� , 415 41 D) 4 ®� -� .r. �- \ �: HP1F5 3 �1 ,' __ ' CAPPE r` cU 4-,,, FSD 34/1' �HP2l /12 CMCS 12/1Q TYP OF 3 �� 16/12 P1C5 o 20/12 CMCS \-IP3/ 24/24 60/24 CAPPED -, .-� cU \ 44/16 44/16 2 P4 CD 80 ---) 290 OA t:: /A 71 5 HHP25 • CMCS 290 290 IAFS : 00 SG '� CD ,—, CR Bl 24/16 415 Fr CRlA6 `� 10/10 4/10 4 --� � ,� 2725 20/16 � _ 3 150 '415H?6 ANL '— I W 60 AFSD 24/12 HP2 8/12 HP1D6 6 SF __ 90 t 1 6 20/16 Li( 750 N -- CR Cl ® ��``~ .� HP3 . L� rvir ''` `�- FD ,—, FD FD 230 , CR1B7 HP1A6A 20/12 Q CD �.+ 30 CD 16/12 G ,\ CD 6� \HP2/ `� 0'• 2725 O �. © N N owl 2 "�- Q 2 CD r, �� 0 `. L-,- IMI 275 '- 80 MI •.+ ��-- .� 16/10x1- �� F1060 Fye F • \ Tori) --,_ 360 6 , 0 16/10 .10/10 --` —'---14/10 275 ,AC1D7A 10/10 --- P1B6 290 23/16 _ �� �. IAC -- ] 2750 P2 '_'' ' CMCS I1 I \ 1-,- 231\ 7 o D \ \ 60 FD A 290 Ecu 8 o 0 230 \HP2/ =I 1211 El I= 1222111=22E1122112 22 SE 1111 112 =I LE MN El SE El El =01 El El =I 11111 Ell Ell 111 CZ El El El =1 Ell Ell =I 112 El =I 101 = 1121 cii = KGB 3 TYP OF 3 � `CD � 2 REMOVAL (C2D MATCH LINE (FOR CONTINUATION SEE SHEET 1M13) QRST FLO=R HVAC PLA\ SCALE: 1/8'=1-0' 1M14 HP1F'7 \HP2/ PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED /16 TYPICAL 6 PL 20/12 AFSD 34/14 AFSD 16/12 44/16 2M13 20/16 20/16 • • AFSD • • • 1M14 M520 16/12 FD 20/16 AFSD A I=1 El IZI MATCH LINE (FOR CONTINUATION SEE SHEET 1M13) PARTIAL FIST SCALE: 1/4°=1 -0' FSi consulting engineers Seattle, Washington Solutions KEY PLAN NO SCALE & Service FLo-R HVAC PLA\ LEGEND: EXISTING WALLS NEW FULL -HEIGHT PARTITION DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AND STC 45 PARTITION STC 45 PARTITION STC 50 PARTITION FD FIRE DAMPER ISSUED FOR CONSTRUCTION OCTOBER 27, 2017 5/4 <EG> REVIEWED FOR CODE COMPLIANCE s•. APPROVED 1 NOV la 201? CVO tukwita BUtl.8ION RECEIVED CITY OF TUKWIL A NV 0 6 2017 PERMIT CENTER 1411'Ol ic- SYM A REVISION BDS LAB PACKAGES 1-5 — H10 34355 BY FSi APPROVED DATE SYM REVISION BY APPROVED DATE AWL 10.12.17 Q�BOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY MCS DEPT. DATE DRAWN D. WILLIAMS DATE 10.01.90 CHECKED M. CAUNITIS ENGINEER M. CAUNITIS CHECKED W. HENCKEL APPROVED K. RAMSEY APPROVED D. SEPTAELKA 10.01.90 10.01.90 10.01.90 10.01.90 SUBTITLE HVAC PLAN CURRENT REVISION 34355 SYMBOL A DATE 10.12.17 TITLE BDS LAB PACKAGES 1-5 — H10 — BOX 10 10.01.90 MECHANICAL MASTER BUILDING 9-08.1 COL. A—F/1-7 DEV. CENTER, WA SHEET IMIOR JOB NO. COMP NO. DWG NO. 9-08-1M1OR SYM A 3/4" DRAIN ED) 3/4"CW DOWN TO HOSE BIBB SEE SHEET UGM110 FOR CONTINUATION CO 3/4" ISOLATION VALVES FOR BOTH SUPPLY AND RETURN ( BOTH UNITS) COND. EVAP. ICO P1P1 C3 3/4" HPWS 3/4" HPWR 1 1/2" HPWR 1 1/2" HPWS PB13� 1" HPWS 1" HPWR av1_, CI CI Ci CI 1/2" PW 1 1/2" HPWR 1 1/2" HPWS 2" HPWS 2" HPWR 1 1/2"HPW 1 1 /2"HPW 1/2" PW 3"HPWS It I 2"HPWS 2"HPWR 5" RWL DN 3/4" PUMPED DRAIN 1/2" PW 1 1/2" HPWS 1 1/2" HPWR CR1A6 1 1/2" HPWS 1 1/2" HPWR 1 P 2" H 2" H 5" RWL DN TYPICAL HEAT PUMP SEE NOTE 1 3/4"CW DOWN SURPLUS TO HOSE BIBB SEE SHEET UGM110 FOR CONTINUATION 3/4" DRAIN CR1C6 HP1 F6 1/2" P 1 1/2" 1 1/2" TON I EBERT, C1D7A 1" HPWS 1" HPWR 1 1/2" ID HP E1 6 O REVISION 1 1/2" ID BDS LAB PACKAGES 1-5 — H10 — BOX 10 34355 BY FSi APPROVED DATE SYM 3/4"CW FOR CONT. SEE SHT 1M111 REVISION 2" V TO TOILET AREA SEE SHT. 1M111 FOR CONT. BELOW RAI •ED 1/4" PUMPED FLOOR. CONDENSATE. MATCH LINES (FOR CONTINUATION SEE SHEET 1M61) FIRST FLOOR PIPING PLAN - C BY APPROVED DATE AWL 10.27.17 PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED Q�BOE/NG 2" V SEE SHT. UGM110 FOR CONT. ACC EPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE FSi consulting engineers Seattle, Washington Solutions & Service DRAWN F. BARBAZADEH CHECD R. MURRAY ENGINEER F. BARBAZADEH CHECKED W. HENCKEL APPROVED K. RAMSEY APPROVED P SFPTFI kA DATE 10.01.90 10.01.90 SUBTITLE LEGE\ 3: EXISTING WALLS NEW FULL—HEIGHT PARTITION DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AND STC 45 PARTITION STC 45 PARTITION --- STC 50 PARTITION GE\RAL \CTES 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. 4. FOR EXACT LOCATION OF HP'S AND CR'S SEE SHEET 1M14. ALSO SEE SCHEDULE ON SHEET M4 FOR PIPE SIZING AND DETAILS A AND TYP. M311 TYP. M521 TYP. M311 CO\STUCTIO\ \OYES: PROVIDE FLEX CONNECTION. KEY PLAN NO SCALE REVIEWED FOR COCEAPCOMPLIANCE PROVED NOV 14 2011 C-4 Tu ILDINGIDNISION ASBESTOS NOTIFICATION A good faith survey of the work area has been conducted and asbestos containing material was not discovered that would ECEIVEQ involved in the construction of this project. Do not req�},OFTUKWIL , damaged or disturb any asbestos material adjacent to the work area. Please contact Boeing Facilities Department if asbest 1 containing material is damaged or discovered that is require ' U 20'� to be removed to support work, PERMIT CENTER The following materials in the areas adjacent to this job assumed to be positive for asbestos: NONE ISSUED FOR CONSTRUCTION OCTOBER 27, 2017 FIRST FLOOR PIPING PLAN 1411/01(6 - CURRENT REVISION 34355 SYMBOL A DATE 10.27.17 TITLE 10.01.90 10.01.90 10.01.90 BDS LAB PACKAGES 1-5 — H10 — BOX 10 in o1.on MECHANICAL MASTER BUILDING 9-08.1 COLA—F/1-7 SHEET 1M60 JOB NO. COMP NO. DEV. CENTER, WA DWG No. 9-08-1M60