HomeMy WebLinkAboutPermit M17-0175 - SABEY - IGE BUILDING AIR DUCTS, CRACT UNITS AND FIRE DAMPERSSABEY - IGE BLDG
3333 S 120T" PL BLDG 3
M17-0175
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
1023049079
3333 S 120TH PL BLDG 3
Project Name: SABEY - IGE BLDG
MECHANICAL PERMIT
Permit Number: M17-0175
Issue Date: 2/12/2018
Permit Expires On: 8/11/2018
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
SABEY CORPORATION
12201 TUKWILA INTL BLVD 4TH FL ,
SEATTLE, WA, 98168
DARLA DOLL
7717 DETROIT AVE SW , SEATTLE, WA,
98106
MACDONALD/MILLER FAC SOL INC
PO BOX 47983 , SEATTLE, WA, 98146-
7983
MACDOFS980RU
Phone: (206) 768-4278
Phone: (206) 768-4180
Expiration Date: 1/4/2019
DESCRIPTION OF WORK:
PROVIDE/INSTALL NEW RETURN AIR DUCTS FOR (21) EXISTING CRAC UNITS. PROVIDE/INSTALL NEW SUPPLY AIR
DUCTS FOR (3) CRAC UNITS. PROVIDE/INSTALL (3) NEW RETURN AIR PENETRATIONS WITH FIRE DAMPERS.
Valuation of Work: $47,553.00
Type of Work: REPLACEMENT
Fuel type: GAS
Fees Collected: $837.11
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125,TUKWILA
Sewer District: VALLEY VIEW
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Date: a - A01 -----( e
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to theEZZgnditions attached to this permit.
Signature: 'V `G ` A— \4k
Print Name:
Date: D-, 19-+ 1
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
7: ***MECHANICAL PERMIT CONDITIONS***
8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
9: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0701 ROUGH -IN MECHANICAL
CITY OF TUKWI,
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. � (7— di -7c
Project No.
1 14--)-1 -H 7
Date Application Accepted:
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.: 023049079
Site Address: 3333 S 120th Pl., Tukwila, WA 98198 Suite Number: Floor: 1
Tenant Name: New Tenant: ❑ Yes ..No
PROPERTY OWNER
Name: Joyce Copley
Name: SABEY CORPORATION
City: Seattle State: WA Zip: 98106
Address: 3333 S 120th P1
Email: joyce.copley@MACMILLER.COM
City: TUKWILA State: WA
Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: Joyce Copley
Address: 7717 Detroit Ave SW
City: Seattle State: WA Zip: 98106
Phone: (206) 406-2614 Fax: (206) 905-3749
Email: joyce.copley@MACMILLER.COM
MECHANICAL CONTRACTOR INFORMATION
Company Name: MacDonald Miller
Address: 7717 Detroit Ave SW
Cin': Seattle State: WA zip: 98106
Phone: (206) 905-3748 Fax: (206) 905-3749
Contr Reg No.: MACDOFS980RU Exp Date: 04/01/2019
Tukwila Business License No.: BUS -0994318
Valuation of project (contractor's bid price): $
Describe the scope of work in detail:
Replace 1 Penthouse Built up Unit 'ith gas/electric packaged rooftop AC unit. Demo HW piping and coil. Abandon boiler in
place.
47,553
Use: Residential: New ❑ Replacement ❑
Commercial: New Replacement ❑
Fuel Type: Electric ❑ Gas ❑
Other:
H:\Applications\Forms-Applications On Line \2016 Applications \Mechanical Permit Application Revised 1-4-1 6.docx
Revised: January 2016
bh
Page 1 of 2 /
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
9
Furnace >100k btu
Industrial
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
Commercial
11epair or addition to
heat/refrig/cooling
system
1
Air handling unit
65 dB(A)
<10,000 cfm
60 dB(A)
Unit Type
Qty
Air handling unit
9
>10,000 cfm
Industrial
Evaporator cooler
55 dB(A)
Ventilation fan
connected to single duct
57 dB(A)
Ventilation system
Commercial
Hood and duct
47 dB(A)
Incinerator — domestic
65 dB(A)
Incinerator —
comm/industrial
60 dB(A)
Unit Type
Qty
Fire damper
9
Diffuser
Industrial
Thermostat
55 dB(A)
Wood/gas stove
57 dB(A)
Emergency generator
Commercial
Other mechanical
equipment
47 dB(A)
60 dB(A)
65 dB(A)
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
1
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
• Warning devices;
• Construction and property maintenance during the daytime hours (7am-lOpm);
• Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 1.05.3.2 International Building Code (current edition).
1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNF•I2 OP A1TTHOR17F.i) AGENT!
Signature: �_21e � Date: 11/20/2017
Print Name: Joyce Copley Day Telephone: (206) 407-2614
Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106
City State Zip
H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx
Revised: January 2016
bh
Page 2 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
3
Furnace >100k btu
Industrial
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
Commercial
Repair or addition to
heat/refrig/cooling
system
47 dB(A)
Air handling unit
26
<10,000 cfm
60 dB(A)
Unit Type
Qty
Air handling unit
3
>10,000 cfm
Industrial
Evaporator cooler
55 dB(A)
Ventilation fan
connected to single duct
57 dB(A)
Ventilation system
Commercial
Hood and duct
47 dB(A)
Incinerator — domestic
26
Incinerator —
comm/industrial
60 dB(A)
Unit Type
Qty
Fire damper
3
Diffuser
Industrial
Thermostat
55 dB(A)
Wood/gas stove
57 dB(A)
Emergency generator
Commercial
Other mechanical
equipment
47 dB(A)
new ductwork runs
26
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
• Warning devices;
• Construction and property maintenance during the daytime hours (lam-1Op 0RRE TION
• Testing of backup generators during the day. (J
RECEIVED
CITY OF TUKWILA
JAN 2 9 2018
PERMIT APPLICATION NOTES
PFRMIT CENTER
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON:, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ..:..: '.:: 1 GE
Signature:
Date: 11/20/2017
Print Name: Darla Doll Day Telephone: (206) 768-4278
Mailing Address: 7717 DETROIT AVE SW
SEATTLE WA 98106
City ` State Zip
H:\Applications\Forma-Applications On Line \2016 Applications\Mechanical Permit Ap cat Reed -16.docx
Revised: January 2016 \` ` ■`
bh
Ot7S
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS 1 ACCOUNT QUANTITY
PermitTRAK
PAID
$837.11
M17-0175 Address: 3333 S 120TH PL BLDG 3 Apn: 1023049079
$837.11
MECHANICAL
$804.91
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
PERMIT FEE
R000.322.100.00.00
0.00
$610.78
PLAN CHECK FEE
R000.322.102.00.00
0.00
$160.98
TECHNOLOGY FEE
$32.20
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R12839
R000.322.900.04.00 0.00
$32.20
$837.11
Date Paid: Tuesday, November 21, 2017
Paid By: MACDONALD-MILLER FACILITY SOLU
Pay Method: CHECK 4759
Printed: Tuesday, November 21, 2017 10:55 AM 1 of 1
CRWSYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
MIii_Oi75
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
,S7113 IG(' P D6 -
Type of Inspection:
Address: �r�
7935 a t' -T' i 1c i
Date Called:
Special Instructions:
13 LPG- 3
Date Wanted:
-a o -t e,
CD
p.m.
Requester:
/Z/C 4 WOLF-
O'-FPhone
PhoneNo:
2E41 - iNO — /887
IKApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
OK I44_0 ' C4L
Inspector:
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
January 30, 2018
City of Tukwila
Department of Community Development
DARLA DOLL
7717 DETROIT AVE SW
SEATTLE, WA 98106
RE: Correction Letter # 2
MECHANICAL Permit Application Number M17-0175
SABEY - IGE BLDG - 3333 S 120 PL
Dear DARLA DOLL,
Allan Ekberg, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments.
• (GENERAL INFORMATION NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised
plan sheets shall be the same size sheets as those previously submitted.)
(If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of
the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature.
Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp,
signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a
bound specification document that contains specifications other than that of an engineering or land surveying
nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is
responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed;
Front page only will be sufficient. (WAC 196-23-010 & 196-23-020)
(BUILDING REVIEW NOTES)
1. Plans stamped and signed by the registered design professional shall include the date of the stamp. See general
note above.
Note: Contingent on response to these corrections, further plan review may request for additional corrections.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
Sincerely,
(-9rAZ
Bill Rambo
Permit Technician
File No. M17-0175
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
City of Tukwila
Department of Community Development
November 29, 2017
JOYCE COPLEY
7717 DETROIT AVE SW
SEATTLE, WA 98106
RE: Correction Letter # 1
MECHANICAL Permit Application Number M17-0175
SABEY - 3333 S 120 PL
Dear JOYCE COPLEY,
Allan Ekberg, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these
comments.
• (GENERAL INFORMATION NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of24x36; all sheets shall bethe same size. New revised
plan sheets shall be the same size sheets as those previously submitted.)
(If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain' the seal/stamp, signature of
the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature.
Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp,
signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a
bound specification document that contains specifications other than that of an engineering or land surveying
nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is
responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed;
Front page only will be sufficient. (WAC 196-23-010 & 196-23-020)
(BUILDING REVIEW NOTES)
1. The scope of work on the permit does not match the scope of work on the plans.
* Provide clarifications as necessary to clarify the scope of work.
* Provide manufacturer's specifications and installation manual for the new equipment.
* Show on the plans the location of the units to be replaced to include location of other mechanical work to be
performed.
* Specify weight of existing and the new mechanical units.
* Include specifications or details for securing the new unit to resist seismic and wind loads.
Note: Contingent on response to these corrections, further plan review may request for additional corrections.
FIRE - M DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments.
• The scope of work stated on the application does not match the scope of work description on the cover sheet of the
submitted plans.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
Sincerely,
Bill Rambo
Permit Technician
File No. M17-0175
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY.
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M17-0175 DATE: 02/05/18
PROJECT NAME: SABEY V IGE BLDG
SITE ADDRESS: 3333 S 120TH PL BLDG 3
Original Plan Submittal Revision # before Permit Issued
X Response to Correction Letter # 1 Revision # after Permit Issued
DEPARTMENTS:
k,)
Building Division
Public Works
Fire Prevention
Structural
Planning Division ❑
❑ Permit Coordinator n
PRELIMINARY REVIEW:
DATE: 02/06/18
Not Applicable ❑ Structural Review Required
(no approval/review required)
REVIEWER.S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 03/06/18
Approved ❑ Approved with Conditions ❑
Corrections Required ❑ Denied ❑
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWERc INITIALS:
DATE:
Permit Center Use Only
!CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW 0 Staff Initials:
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M17-0.175 DATE: 01/29/18
PROJECT NAME: SABEY
SITE ADDRESS: 3333 S 120 PL
Original Plan Submittal Revision # before Permit Issued
X Response to Correction Letter # 1 Revision # after Permit Issued
DEPARTMENTS:
A. COWS
Building Divis o
Public Works
AA 44 -
Fire Prevention I Planning Division
Structural
❑ Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 01/30/18
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 02/27/18
Approved
Corrections Required L
(corrections entered in Reviews)
Approved with Conditions
Denied
(ie: Zoning Issues)
n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED: I-301
Departments issued corrections: Bldg 41. Fire 0
Ping 0 PW ❑
Staff Initials:
12/18/2013
PERMIT COORD COPY_.
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M17-0175 DATE: 11/21/17
PROJECT NAME: SABEY
SITE ADDRESS: 3333 S 120 PL
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Cove
Building Division
Public Works
AR coueIZ 1\9-e-17
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 11/23/17
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)' (ie: Zoning Issues)
DUE DATE: 12/21/17
Approved with Conditions ❑
Denied
Notation:
REVIEWER'S INITIALS:
DATE:
,Permit Center Use Only
CORRECTION LETTER MAILED: 1—?'q`I
Departments issued corrections: Bldg— Fire Ping ❑ PW 0 Staff Initials:_
12/18/2013
Date: as
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Plan Check/Permit Number:
❑ Response to Incomplete Letter #
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
❑ Deferred Submittal #
Project Name:
5PIVDE -.LSC i�L}
Project Address: 33 !la0±h' 1 P ` 10 1 1C&
Contact Persona-- Q_ Phone Number:
Summary of Revision:
7 CR
RFCFIVFU
CITY OF TUK lkiliP.
EER 0 "7 9213
PERMIT CFNTEF:•
Sheet Number(s):
"Cloud" or highlight all areas of revision including ate # re
Received at the City of Tukwila Permit Center by:
Entered in TRAKiT on
W:\Permit Center (Brcnda)\Forms\Permit Center Documents (Word)'Revision Submittal Form.doc
Revised: August 2015
scon�/��
�
r I"'1V
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: ,
Plan Check/Permit Number:
❑ Response to Incomplete Letter #
Response to Correction Letter # 1
❑ Revision # after Permit is Issued
MI1-D195
❑ Revision requested by a City Building Inspector or Plans Examiner
❑ Deferred Submittal #
Project Name: S\IS
Project Address. 5555 s t 1-O-1-1/1 PI T kw l l a 1 N owL2
L2
Contact Person: Phone Number:
Summary of Revision:
rz_outditmet Mlefatl- Sc oLo k
-tv C,g-ctiC.. u. k)(LD-utcat ln*Ill raw
v Pt at(' S icp-e.(3) fIQW
(\n*a.it If tk) ktu
RECEIVED
CITY OF TLJKV TL ,
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revisi i.n
Received at the City of Tukwila Permit Center by:
Entered in TRAKiT on 1-->q
`i S
W:\Permit Center (Brenda)Worms\Permit Center Documents (Word)\Revision Submittal Form.doc
Revised: August 2015
(PERMIT CENTER
MACDONALD/MILLER FAC SOL Page 1 of 3
Nome Espanol Contact:
Safety & Health Claims & Insurance
CWashington State Department of
P Labor & Industries
Search L&I
A-Zlndex help
7I v#``af"f
My L&l
Workplace Rights Trades & Licensing
MACDONALD/MILLER FAC SOL INC
Owner or tradesperson
Principals
SIMONDS, DERRICK R, PRESIDENT
WEBSTER, MARK E, VICE PRESIDENT
GEBHARDT, STEPHANIE
WETTACH, TREASURER
NOEL, STEPHANIE W, MEMBER
SIGMUND, FREDRIC, PRESIDENT
(End: 01/04/2011)
LOVELY, STEVE C, VICE PRESIDENT
(End: 01/04/2011)
HACK, RICHARD, SECRETARY
(End: 01/04/2011)
KOPET, TYLER, TREASURER
(End: 01/04/2011)
TURLEY, DOUGLAS, CHIEF EXECUTIVE
OFFICER
(End: 01/04/2011)
TURLEY, DOUGLAS, CHIEF OPERATING
OFFICER
(End: 01/04/2011)
GOUGH, DAVID ANTHONY, DIRECTOR
(End: 08/29/2014)
Doing business as
MACDONALD/MILLER FAC SOL INC
WA UBI No.
602 254 260
PO BOX 47983
SEATTLE, WA 98106
206-768-4180
KING County
Business type
Corporation
Governing persons
FREDRIC
J
SIGMUND
STEVE C LOVELY;
TYLER C KOPET;
License
Verify the contractor's active registration / license / certificatio.n (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
MACDOFS980RU
Effective — expiration
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS980RU&SAW= 2/12/2018
MACDONALD/MILLER FAC SOL INC
12/31/2002— 01/04/2019
Bond
..............
LIBERTY MUTUAL INS CO
Bond account no.
023006951
$12,000.00
Received by L&I Effective date
12/31/2002 12/11/2002
Expiration date
Until Canceled
Insurance
............................
Phoenix Insurance Company, The $1,000,000.00
Policy no.
DT-CO-3K790954-PHX-1
Received by L&I Effective date
01/02/2018 12/31/2017
Expiration date
12/31/2018
Liberty Mutual Ins Co
Policy no.
TB7-661-066178-033
$2,000,000.00
Received by L&I Effective date
11/20/2017 12/31/2013
Expiration date
12/31/2018
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
....... ......... _ ...................
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID
252..,4.57-05
....... ....................
Doing business as
MACDONALD MILLER FACILITY
Estimated workers reported
Quarter 4 of Year 2017 "Greater than 100 Workers"
L&I account contact
T4 / STEPHEN TASSONI (360)902-4819 • Email: TASS235@Ini.wa.gov
Account is current.
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
...._.................................._....._......
No strikes have been issued against this contractor.
Contractors not allowed to bid
.............................................................................................
No debarments have been issued against this contractor.
Workplace safety and health
Check for any past safety and health violations found on jobsites this business was responsible for.
Inspection results date
08/24/2015
Inspection no.
Violations
Page 2 of 3
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS980RU&SAW= 2/12/2018
Cr, Temob
0
w
1-
VI
n
t
3
i
o+
C
c
W
J:\7317\6881 ICE Bldg 3 COLO 2 & 3 LL0\00\2
FILE COPY
Permit No. M1'1" 0\1Cj
Plan review e?proval is subject to errors and omissions.
Approval of co ns:, uction documents doss not authorize
the violation of any adopted coda or ordinance. Receipt
of approved Field Copy and condi ions is acknowledged:
Dwak - U
By:
Data:
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall h' made to the .scope
of work witho! '; prior approval of
Tulo.vi{a 61 f;': f;r,q Division.
NOTE. RTA.t.:7r7Zt• Ul rocqufr i I i °,v plan submittal
and may f`'.-,:l.:::n ac'c'"I naI pian review fee's
SEPARATE PERMIT
REQUIRED FOR:
❑ lachanicaI
tE Electrical
j'lumbtng
Gas Piping
Ci -y of Tukwila
HVAC GENERAL AE3BREVIATIONt
ABBV
FULL NAME
ABBV
AC
AFF
AHU
AL
BAS
BDD
81
BOD
BOTT
BTU
BTUH
CAT1
CAT4
CFM
CPVC
DB
DDC
DEMO
DIFF
DMPR
DN
E
EAT
EC
EER
EF
ELEV
ESP
EWT
AIR CONDITIONING UNIT
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
ALUMINUM
BUILDING AUTOMATION SYSTEM
BACK DRAFT DAMPER
BLACK IRON
BOTTOM OF DUCT
BOTTOM
BRITISH THERMAL UNITS
BRITISH THERMAL UNITS PER HOUR
CATEGORY ONE VENT
CATEGORY FOUR VENT
CUBIC FEET PER MINUTE
CPVC MATERIAL
DUCTBOARD
DIRECT DIGITAL CONTROLS
DEMOLISH
DIFFUSER
DAMPER
DOWN
EXISTING
ENTERING AIR TEMPERATURE
EGGCRATE
ENERGY EFFICIENCY RATIO
EXHAUST FAN
ELEVATION
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
FCU
FD
FLA
FOB
FOT
FSD
GALV
GC
GENX
GLVNL
GPM
GREASE
GWB
HP
HVAC
HX
ID
LAT
LBS
LWT
MAT
MBH
MCA
MD
MIN
M -M
NC
NIC
NO
FULL NAME
FAN COIL UNIT
FIRE DAMPER
FULL LOAD AMPS
FLAT ON BOTTOM
FLAT ON TOP
FIRE SMOKE DAMPER
GALVANIZED
GENERAL CONTRACTOR
GENERATOR EXHAUST
GALVANNEAL
GALLONS PER MINUTE
GREASE DUCT
GYPSUM WALL BOARD
HORSE POWER, HEAT PUMP
HEATING, VENTILATION AND AIR CONDITIONING
HEAT EXCHANGER
INSIDE DIMENSION
LEAVING AIR TEMPERATURE
POUNDS
LEAVING WATER TEMPERATURE
MIXED AIR TEMPERATURE
ONE THOUSAND BTUH
MINIMUM CIRCUIT AMPACITY
MOTORIZED DAMPER
MINIMUM
MACDONALD-MILLER
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
ABBV
NOM
NTS
OBD
OD
POC
PRV
PVC
REQ'D
RPBA
RTU
SA
SD
SL
SM
SP
SS
SUSP
T
TOD
TV
TYP
UNO
VAV
VD
VFD
W
W/
WELD
0
FULL NAME
NOMINAL
NOT TO SCALE
OPPOSED BLADE DAMPER
OUTSIDE DIMENSION
POINT OF CONNECTION
PRESSURE REDUCING VALVE
POLYVINYL CHLORIDE
REQUIRED
REDUCED PRESSURE BACKFLOW ASSEMBLY
ROOFTOP UNIT
SUPPLY AIR
SMOKE DAMPER
SOUND LINED
SHEET METAL
STATIC PRESSURE
STAINLESS STEEL
SUSPENDED
THERMOSTAT
TOP OF DUCT
TURNING VANES
TYPICAL
UNLESS NOTED OTHERWISE
VARIABLE AIR VOLUME
VOLUME DAMPER
VARIABLE FREQUENCY DRIVE
DUCT INSULATION WRAP
WITH
WELDED
VOLTAGE PHASE & DUCT DIAMETER
ABBV
FULL NAME
ABBV
HVAC SYSTEM ABBREVIATION
FULL NAME
ABBV
FULL NAME
AR
C
CA
CDWR
CDWS
CHRV
CHWR
CHWS
CLN STM
COMB
CRYV
EA
FLU
FOC
FOF
FOR
FOS
FOV
HE
ARGON
CONDENSATE
COMPRESSED AIR
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CHILLER RELIEF VENT
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CLEAN STEAM
COMBUSTION AIR
CRYOGEN VENT
EXHAUST AIR
FLUE VENT
FUEL OIL SECONDARY CONTAINMENT
FUEL OIL FILL
FUEL OIL RETURN
FUEL OIL SUPPLY
FUEL OIL VENT
HELIUM
HHWR
HHWS
HPC
HPS
HRR
HRS
IA
IA -IN
LA
LA -IN
LPC
LPG
LPS
MPC
MPS
MUA
MUW
NG-2PSI
NG-5PSI
HEATING HOT WATER RETURN
HEATING HOT WATER SUPPLY
HIGH PRESSURE STEAM CONDENSATE
HIGH PRESSURE STEAM
HEAT RECOVERY RETURN
HEAT RECOVERY SUPPLY
INSTRUMENT AIR
INSTRUMENT AIR INTAKE
LAB AIR
LAB AIR INTAKE
LOW PRESSURE STEAM CONDENSATE
LIQUID PROPANE
LOW PRESSURE STEAM
MEDUIM PRESSURE STEAM CONDENSATE
MEDIUM PRESSURE STEAM
MAKE-UP AIR
MAKE UP WATER
MEDIUM PRESSURE NATURAL GAS - 2PSI
MEDIUM PRESSURE NATURAL GAS - 5PSI
NG -H
NG -L
NG -V
OA
PC
PCHR
PCHS
RA
RGAS
RLF
RLIQ
RSUC
SCHR
SCHS
SPC
SV
SVA
VAC
VAC -E
HIGH PRESSURE NATURAL GAS
LOW PRESSURE NATURAL GAS
NATURAL GAS VENT
OUTSIDE AIR
PUMPED CONDENSATE
PROCESS CHILLED WATER RETURN
PROCESS CHILLED WATER SUPPLY
RETURN AIR
REFIGERANT HOT GAS
RELIEF AIR
REFIGERANT LIQUID
REFIGERANT SUCTION
SECONDARY CHILLED WATER RETURN
SECONDARY CHILLED WATER SUPPLY
STEAM PUMPED CONDENSATE
STEAM VENT
STEAM VENT ATMOSHPERIC
VACUUM
VACUUM EXHAUST
PER SCHEDUL
SYMBOL DESCRIPTION -POWERED
1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE. VERTICAL
OR HORIZONTAL , 165° F FUSABLE LINK, BLADE IN AIR STREAM,
GREENHECK DFD 150 TYPE A OR EQUAL.
FD -1
NOTES SYMBOL DESCRIPTION -NON POWERED
NOTES
NOTES:
1. ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR
2. INTERLOCK OF SMOKE DAMPER TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR
3. CONTROL FROM LOCAL DETECTOR
4. CONTROL FROM DUCT DETECTOR
5. OPEN/CLOSED POSITION INDICATOR
6. DAMPER FAILS OPEN
7. DAMPER FAILS CLOSED
FFUSER/GRILLE SCHEDUL
SYMBOL
MANUFACTURER & MODEL NUMBER
SIZE
TYPE
NOTES
/\SIZE
CFM
SHOEMAKER 905 -DW
AS NOTED
SURFACE MT RET/EXH GRILLE
M -M METAL EGGCRATE
12/24
RETURN/EXH
N
M -M METAL EGGCRATE
24/24
RETURN/EXH
ACE CODE NOTES (2015'
1.
2.
3.
COOLING AND HEATING LOADS HAVE BEEN PERFORMED PER ASHRAE STANDARDS.
PROVIDE HVAC EQUIPMENT SIZED NO LARGER THAN THE NEXT LARGER AVAILABLE EQUIPMENT SIZE ABOVE CALCULATED LOADS.
ALL MOTORS, EXCEPT THOSE INCLUDED IN EQUIPMENT WITH EFFICIENCY RATED AS A WHOLE UNIT, SHALL BE ENERGY EFFICIENT MOTORS MEETING NEMA STANDARD MG -1.
4. UNLESS OTHERWISE NOTED, FAN MOTORS SHALL BE THE SMALLEST AVAILABLE MOTOR HP SIZE GREATER THAN THE FAN BHP.
5. ALL MOTORS 1/12 HP TO 1 HP SHALL BE ELECTRONICALLY COMMUTED (EC) TYPE.
6. CONTROLS SHALL USE A MINIMUM DEADBAND BETWEEN HEATING AND COOLING OF 5°F.
7. CONTROLS SHALL BE CONFIGURED TO SET BACK UP TO 85°F OR DOWN TO 55°F.
COMMISSIONING IN COMPLIANCE WITH 2015 WASHINGTON STATE ENERGY CODE (WSEC) SHALL BE REQUIRED FOR ALL NEW SYSTEMS OR MODIFIED PORTIONS OF SYSTEMS UNLESS THE SYSTEMS MEET
ONE OR MORE OF THE FOLLOWING EXCEPTIONS:
EXCEPTION 1: SYSTEMS WITH A BUILDING TOTAL COOLING CAPACITY OF LESS THAN 20 -TONS AND HEATING CAPACITY LESS THAN 300,000 BTU/H.
THE COMMISSIONING PROCESS SHALL BE REQUIRED BY 2015 WSEC SECTION C408 AND INCLUDE: 1) A COMMISSIONING PLAN; 2) SYSTEMS TEST AND BALANCE; 3) HVAC EQUIPMENT AND HVAC CONTROLS
FUNCTIONAL TESTING; 4) MANUALS, RECORD DOCUMENTS, AND TRAINING; AND 5) COMMISSIONING REPORT
COMMISSIONING DOCUMENTATION SHALL BE AS REQUIRED IN 2015 WSEC SECTION C408 AND INCLUDE 1) RECORD DOCUMENTS; 2) OPERATION AND MAINTENANCE MANUALS; 3) SYSTEM BALANCING
REPORT; 4) A FINAL COMMISSIONING REPORT.
RECORD DRAWINGS THAT ARE UPDATED AND REDLINED TO INDICATE THE SYSTEM AND EQUIPMENT AS INSTALLED SHALL BE PROVIDED ACCORDING TO 2015 WSEC SECTION C103.6.1
A FINAL COMMISSIONING REPORT SHALL BE AS REQUIRED BY 2015 WSEC SECTION C408.1.3 AND INCLUDE 1) RESULTS OF FUNCTIONAL PERFORMANCE TESTS; 2) DESCRIPTION OF DEFICIENCES FOUND
DURING TESTING AND DETAILS OF CORRECTIVE MEASURES; 3) FUNCTIONAL PERFORMANCE TEST PROCEDURES
SYSTEMS OPERATIONS TRAINING SHALL BE PROVIDED AS REQUIRED BY 2015 WSEC SECTION C103.6.4 AND INCLUDE 1) REVIEW OF SYSTEMS DOCUMENTATION; 2) HANDS-ON DEMONSTRATION OF
MAINTENANCE AND OPERATION; AND 3) TRAINING COMPLETION REPORT
1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO
VERIFY ALL CLEARANCES BEFORE COMMENCING WORK.
2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2015 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE
CODE AND STATE AND LOCAL CODES AND ORDINANCES.
3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2015 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE
SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM.
4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT.
5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2015 WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS
- DUCT WRAP, WHERE INDICATED, SHALL BE 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER.
- SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM.
- DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT.
- SUPPLY DUCT WHICH CONVEYS SUPPLY AIR AT TEMPERATURES LESS THAN 55 DEG F OR GREATER THAN 105 DEG F WHEN LOCATED IN CONDITIONED SPACE SHALL BE INSULATED WITH A MINIMUM OF R-3.3 ,
WHEN LOCATED IN UNCONDITIONED SPACE R-6 AND WHEN LOCATED OUTSIDE THE BUILDING R-8 (CLIMATE ZONE 4) OR R-12 (CLIMATE ZONE 5) PER WSEC C403.2.8.2.
- OUTSIDE AIR DUCT INSULATION SHALL MATCH BUILDING ENVELOPE INSULATION VALUES UNLESS SERVING INDIVIDUAL SUPPLY AIR UNITS WITH LESS THAN 2800 CFM OF TOTAL SUPPLY AIR CAPACITY,
PROVIDED THESE ARE INSULATED TO R-7 MINIMUM PER WSEC C403.2.8.1.
6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS
1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE.
7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2015 IBC.
8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2015 IBC. PROVIDE CEILING FIRE DAMPERS WHERE
INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2015 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS
INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE.
9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL.
10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION
606 OF THE 2015 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. BAS TO MONITOR FIRE ALARM CONTROL PANEL AND SHUT
DOWN ALL FAN TERMINAL UNITS DURING ANY BUILDING FIRE ALARM EVENT, IN ACCORDANCE WITH IMC 606.2.2.
11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED
AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18".
12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING
WITH ELECTRICAL CONTRACTOR.
13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.
14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS
A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL
AIR AND WATER DESIGN FLOW RATES.
15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC
CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM.
16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC), COMMERCIAL PROVISIONS AND SECTION C408.
17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER
18. SHAFT WALLS CONSTRUCTED TO SUPPORT AIR MOVEMENT FOR RETURN AIR SYSTEMS AND STAIR & ELEVATOR PRESSSURIZATION SYSTEMS SHALL BE CONSTRUCTED
TO THE FOLLOWING STANDARDS:
A. SHAFTS (RATED FOR MAXIMIUM 2" WC) SHALL BE CONSTRUCTED TO WITHSTAND 15 PSF LOADING WITH A DEFLECTION OF L/360 (UNO).
B. SHAFTS SHALL BE SEALED SUBSTANTIALLY AIR -TIGHT USING THE CRITERIA FROM THE INTERNATIONAL BUILDING CODE:
1. SECTION 715.6 FIRE RESISTANT JOINT SYSTEMS IN SMOKE BARRIERS: LEAKAGE SHALL NOT EXCEED 5 CFM PER LINEAR FOOT OF JOINT AT 0.3" WC.
2. SECTION 909.5 SMOKE BARRIER CONSTRUCTION FOR INTERIOR EXIT STAIRWAYS AND EXIT PASSAGEWAYS: MAXIMUM ALLOWABLE LEAKAGE AREA
PER SHAFT SHALL NOT EXCEED (0.00035 SF/SF)
C. STAIR AND ELEVATOR PRESSURIZATION SHAFTS SHALL BE PRESSURE TESTED DURING COMMISIONING. CONTRACTOR SHALL MAKE MODIFCATIONS TO
INSTALLATION UNTIL SHAFT IS IN COMPLIANCE.
19. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500D): MOTORIZED DAMPERS: 4 CFM/S.F.
GRAVITY DAMPERS: 20CFM/S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION).
20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC, COMMERCIAL PROVISIONS, SECTION C403.2.4.3 EXCEPT AS
ALLOWED BY WSEC.
LEGAL DESCRIPT
APN#: 1023049079
LEGAL DESCRIPTION: LOT 3 OF TUKWILA BLA #L04-060 REC #20041008900012 LOCATED IN SE 1/4 OF SEC 9 & SW 1/410 IN 23-04
ING SHEET IND
NAME TITLE
NAME
TITLE
TM0.01 SCHEDULES - HVAC
TM0.01S SITE MAP
TM2.01A 1ST FLR PARTIAL PLAN - HVAC
TM2.01 B 1ST FLR PARTIAL PLAN - HVAC
PROVIDE/INSTALL NEW RETURN AIR DUCTS FOR 21 EXISTING CRAC UNITS. PROVIDE/INSTALL NEW SUPPLY AIR DUCTS FOR (3) CRAC UNITS. PROVIDE/INSTALL (3) NEW RETURN AIR PENETRATIONS W/FIRE DAMPERS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 0 7 2018
•
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 2 2018
PERMIT CENTER
CORRECTION
LTR#
fid.
E
0
iv
E
U
f0
E
MACDOFS980RU
Z
02/01/2018
1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1
I I I I I �I
0
N
0
0
1 1 1 1
0
J
J
CO
cso
N
RECTION 1
NI
0
cV
1
1-
w
00
0 U
ENGINEER:
T VANDOOREN
CHECKED BY:
B GEZON
CAD:
w
0
REVISIONS:
w
Q
0
REVISIONS:
z
0
U
Cf)
z
0
U
0
0
W
VJ
LAST REVISED:
01-08-18
DATE PLOTTED:
01-08-18
ISSUE DATE
T VANDOOREN 01-08-18
DRAWING NUMBER:
D-3861-73176881-00
SHEET NUMBER:
TM0.01
3
0
a
67,171
3
0
rn
c
.c
m
c
w
1 /
N
0
0
M
CTI
08, 2018 8:59:27
a
0
0
0
/
/
/
/
/
/
/
/
/
/
/
/
/
H //////////////// 1 //I/,/I/„////////////IL//
1'I �i
•
J
T U K WILA U0/
ZONE — INDUS
”
RIAL
A
6.22 AC.
TUKWILA "MI /H"
ZONE INDUSTRIAL
as
CO CO
co 0
co
o
CI) co
CD 0
• ny-
CD
O 6
o
.macmiller.com
WA Lic No: MACDOFS980RU
/i
///////////\//////////A
II
ff
1
IvTERNATIOvAL
GATEWAY EAST it
12201 TUKW L A
INTERNATIONAL BLVD
SEATTLE, WA 98168
FRAVERSO
IDRODIRTIES
11025 SE 601 ST
BELH-IVUE--_, WA 98168
ru
— INDUST IAL
3333 S 120TH PL,
TUKWILA, WA. 98168
.D0 BOX 2769
KE CHLM, ID 853L
NTERNATI ONAL
GATEWAY EAST II!
12201 - _I KWILA
INTERNATIONAL BLVD
SEA TILE WA 98168
if
IN TE INATIONAL
GATIWAY EAST IV
IN TERNATIONAL
GATEWAY EAST IV
REVIEVVED FOR
CODEICOMPLIANCE
ApPROVED
F93. 07 2018
CiW of Tukwila
BUILDING DIVISION
I RECEIVED
CITY OF TUKWILA
FEB 0 2 2018
PERMIT CENTER
02/01/2018
11111111
11111111
1 1 1 1 1 I :11
co N-
o
oo
CO
>-
co
CO
co
co
co
ENGINEER:
00
C▪ O
0 1-
E m
Et 11
REVISIONS:
LAST REVISED:
0
0
0
LIJ
(1)
T VANDOOREN 01-08-18
CHECKED BY:
B GEZON
DATE PLOTTED:
01-08-18
ISSUE DATE
T VANDOOREN 01-08-18
DRAWING NUMBER:
SHEET NUMBER:
TMO 01S
J:\7317\6881 IGE Bldg 3 COLO 2 & 3 LLO\00\2
SEE SHEET DWG NO. TM2.01 B
__FDS
COLO-3-CAHU-7
COLO-3-CAHU-8
COLO-3-CAHU-9
000000
). 124X34
RA
G.C. TO PROVIDE TWO NEW
44X18 WALL OPENINGS UNDER
THE FLOOR (TYP. 2). PROVIDE
FULL SIZE FIRE DAMPERS. SUPPLY
AIR SCOOP OF COLO-3-CAHU-7
& COLO-3-CAHU-8 TO BE
REVERSED, DIRECTING AIR
THROUGH NEW OPENINGS.
COLO-2-CAHU-1
COLO -2 -CAH U-10
EXTEND RETURN AIR DUCTS OF
COLO-2-CAHU-7 THRU COLO-2-CAHU-10
UP TO 13'-0" ELEVATION ABOVE
RAISED FLOOR (TYP. 4)
GENERAL NOTES:
1. G.C. TO REMOVE GRID CEILING IN
COLO -2
EXTEND RETURN AIR DUCTS OF
COLO-2-CAHU-6
UP TO 15'-0" ELEVATION
ABOVE RAISED FLOOR
_J
0
COLO-2-CAHU-2
COLO-2-CAHU-9
LCOLO-2-CAHU-6
000000
1
J
LJ
COLO-2-CAHU-8
COLO-2-CAHU-7
EXTEND RETURN AIR DUCTS OF
COLO-2-CAHU-1
UP TO 15'-0" ELEVATION
G.C. TO PROVIDE TWO NEW
44X18 WALL OPENINGS UNDER
THE FLOOR. PROVIDE FULL SIZE
FIRE DAMPERS. SUPPLY AIR SCOOP OF
COLO-1-CAHU-1 TO BE REVERSED, �-_-
DIRECTING AIR THROUGH NEW
OPENINGS.
® 124X34
RA
EXTEND RETURN AIR DUCTS OF
COLO-2-CAHU-3 THRU COLO-2-CAHU-5
UP TO 13'-0" ELEVATION ABOVE
RAISED FLOOR (TYP. 4)
COLO-2-CAHU-3
COLO-2-CAHU-4
COLO-2-CAHU-5
c-'
EXTEND RETURN AIR DUCTS OF
/COLO-1-CAHU- 1 , COLO-3-CAHU-7,
& COLO-3-CAHU-8 UP TO 10'-0" ELEVATION
COLO-1-CAHU-4
ABOVE RAISED FLOOR BEFORE PROVIDING AN ELBOW TO
TWO NEW 48X44 OPENING IN WALL BY G.C.
PROVIDE FULL SIZE FIRE DAMPER. (TYP. 3)
COLO-1-CAHU-1
COLO -1 -CAHU-9
COLO -1 -CAHU-3
COLO -1 -CAHU-2
0
COLO -1 -CAHU- 1 0
COLO -1 -CAH U- 1
COLO -
DC POWER
DC POWER
NETWORK -CAHU- 1
V-UPS-CAHU-2
000000
NETWOR
l D -C l-CAHU;-2
V-UPS-CAHU-1 •
B-C-CAHU- 1
IL_
000.00
r
000000
000000
C-UPS-CAHU-2
C-UPS-CAH U-3
T
C
- UPS -CAH U-1
l
\�I
C-UPS-CAHU-4
REVIEWED FOR
COD CQMPLIANCE
APPROVED
?r !
FEB.647 X 018
S �.� -_,
w E
— — J
J
Cit\9f, Tykw'Ia
BUILD NG;DI:VISION
RECEIVED i.
CITY OF TUKWILA
UP
FEB 0 2 2018
PERMIT GENIER
cirai
CO CO
CO CO
<
N.
dj O
N
fB
N
ALL
-O
0O
C C)
1
.o O
• N
o ff;
I- C
r O
CL
www.macmiller.com
WA Lic No: MACDOFS980RU
02/01/2018
1 1 1 1 1 1 1 1
0
REVISIONS:
I I I I I I0°Ir:Li w
� cV
0
J
CO
V
0
J
0
CO U
rn co
V �
—I >-- g
Q J o0
m W N _
W CO co
co
() M
ENGINEER:
I
0
I
0
N
CORRECTION 1
/ \ CD/PERMIT SET
REVISIONS:
LAST REVISED:
SSU ED FOR CONSTRUCTION
T VANDOOREN 01-08-18
CHECKED BY:
DATE PLOTTED:
B GEZON 01-08-18
CAD: ISSUE DATE
T VANDOOREN 01-08-18
4
DRAWING NUMBER:
D-3861-73176881-00
SHEET NUMBER:
TM2.01A
0
I
J:\7317\6881 IGE Bldg 3 COLO 2 & 3 LL0\00\2
N
0)
N
to
co
O
N
o
O
0
0
0
0
0 0
10
SEE SHEET DWG NO. TM2.01A
GENERAL NOTES:
1. G.C. TO REMOVE GRID CEILING IN
COLO -3
COLO-3—CAHU-7
COLO-3—CAHU-4
COLO-3—CAHU-3 j
i
J
—11
EXTEND RETURN AIR DUCTS OF
COLOT-3—CAHU-1 THRU COLO-3—CAHU-6
UP—TO 13'-0" ELEVATION ABOVE
RAISED FLOOR (TYP. 6)
COLO-3—CAHU-5
COLO-3—CAHU-6
COLO-3—CAHU-8
COLO-3—CAHU-2
COLO-3-CAHU-1
Ek(TEND RETURN AIR DUCTS OF
COLO-3—CAHU-9 THRU COLO-3—CAH U-10
UPj TO 15'-0" ELEVATION ABODE
RAISED FLOOR (TYP. 2)
COLO-3—CAHU-9
COL-O-3—CAH U-10
oaooro
L
CE)
4x8
COLO-1—CAH U-6
COLO -1 —CAHU-5
COLO -1 —CAHU-7
COLO -1 —CAHU-8
COLO-1—CAH U-4
COLO -1 —CAHU-9
Mt
EVIEV D FOR—
CODE
OSCODE COMPLIANCE
APPROVED
FEB 0 7 2018
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 2 2018
PERMIT CENTER
CO CO
O I-
N— N-
CO
O O
O
< co
co
(176-
0 Qj O
• N
O as
ALL
• O
N p
C p)
Q (fl
ti
w ,
O
O
N
0
I— 0 O
I� L
r-
02/01/2018
'-
.macmiller.com
WA Lic No: MACDOFS980RU
02/01/2018
11 1 1 1 1 1 I
0
J
CO
N
0
J
0
U
CO
0
J >-
0o
w 00
ENGINEER:
CO
m
J co
0.
O
N
CO
co
co
co D
cO
00I
0
cV
N.1
0
CV
CORRECTION 1
/ \ CD/PERMIT SET
w
0
REVISIONS:
UJ
0
z
0
U5
ct
LAST REVISED:
z
0
U
(n
z
0
U
0
LL
0
L1.1
(1)
(1)
T VANDOOREN 01-08-18
CHECKED BY:
B GEZON
CAD:
DATE PLO IILO:
01-08-18
ISSUE DATE
T VANDOOREN 01-08-18
DRAWING NUMBER:
D-3861-73176881-00
SHEET NUMBER:
M2....O. 1B