HomeMy WebLinkAboutPermit M17-0182 - TARGET AGENT GRID - ROOFTOP HEAT PUMPTARGET AGENT GRID
17640 WEST VALLEY HWY
M17-0182
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
2523049017
17640 WEST VALLEY HWY
Project Name: TARGET AGENT GRID
MECHANICAL PERMIT
Permit Number:
Issue Date:
Permit Expires On:
M 17-0182
12/11/2017
6/9/2018
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
TERRENO 17600 WVH LLC
101 MONTGOMERY ST #200, SAN
FRANCISCO, WA, 94104
JESSE CHUTICH
3202 C ST NE , AUBURN, WA, 98002
COMFORT MECHANICAL INC
(CONSTRUCT)
3202 C ST NE , AUBURN, WA, 98002
COMFOM1015LA
Phone: (425) 251-9840
Phone: (425) 251-9840
Expiration Date: 4/25/2018
DESCRIPTION OF WORK:
REPLACE (1) 2.5 -TON ROOFTOP HEAT PUMP LIKE FOR LIKE
Valuation of Work: $5,751.00
Type of Work: REPLACEMENT
Fuel type: ELECT
Fees Collected: $285.78
Electrical Service Provided by: PUGEST SOUND ENERGY
Water District: RENTON
Sewer District: RENTON
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature: /�
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
it PA
2017
2017
2017
2015
Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name: �JeSS.0
Date:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: Readily accessible access to roof mounted equipment is required.
4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
7: ***MECHANICAL PERMIT CONDITIONS***
8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
9: Manufacturers installation instructions shall be available on the job site at the time of inspection.
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
0703 MECH EQUIP EFF
1800 MECHANICAL FINAL
0609 PIPE/DUCT INSULATION
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TulcwilaWA.gov
Mechanical Permit No. r1/41 ( 1'0 t
Project No.
Date Application Accepted:
Date Application Expires: s',– 30—( V
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
/ ' l King Co Assessor's Tax No.: Zs -230y -10/ 7
Site Address: / 76, yo \✓es � vo( / (e y �l w y Suite Number:
Tenant Name: q t c1 ¢, �- Iq c�t n i' G r i d
!
PROPERTY OWNER
Name: Jesse Chutich
Name:
e,rre,1)®
(
City: Auburn State: WA Zip: 98002
Address: J moo
v41! ya 1-1g...
City: T�l k W 1
State:(! Zip. "lg 1 b �p
v
CONTACT PERSON – person receiving all project
communication
Name: Jesse Chutich
Address: 3202 C St NE
City: Auburn State: WA Zip: 98002
Phone: (425) 251-9840 Fax:
Email: jesse@comfortmech.com
Floor:
New Tenant: ❑ Yes
0
MECHANICAL CONTRACTOR INFORMATION
Company Name: Comfort Mechanical Inc.
Address: 3202 C St NE
City: Auburn State: WA Zip: 98002
Phone: (425) 251-9840 Fax:
Contr Reg No.: COMFOM1015LA Exp Date: 04/25/2018
Tukwila Business License No.: BUS -0993365
Valuation of project (contractor's bid price): $ S, 7 (
Describe the scope of work in detail:
Re?ll►C.As 0) 1,S- -lair roof fop I- e t p t eke for (;ke
Use: Residential: New
Commercial: New
Fuel Type: Electric
Replacement
Replacement
Gas ❑
Other:
H:\Applications\Fortes-Applications On Line \2016 Applications\Mechanical Permit Application Revised I-4-16.docx
Revised: January 2016
bh
E
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type .
Qty
Furnace <1OOk btu
1
Furnace >100k btu
Industrial
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
Commercial
Repair or addition to
heat/refrig/cooling
system
47 dB(A)
Air handling unit
65 dB(A) .
<10,000 cfin
60 dB(A)
Unit Type
Qty
Air handling unit
Residential, Nighttime
>10,000 cfm
Industrial
Evaporator cooler
55 dB(A)
Ventilation fan
connected to single duct
57 dB(A)
Ventilation system
Commercial
Hood and duct
47 dB(A)
Incinerator — domestic
65 dB(A) .
Incinerator —
comm/industrial
60 dB(A)
Unit Type
Qty
Fire damper
Residential, Nighttime
Diffuser
Industrial
Thermostat
55 dB(A)
Wood/gas stove
57 dB(A)
Emergency generator
Commercial
Other mechanical
equipment
47 dB(A)
60 dB(A)
65 dB(A) .
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+hp/1,750,000 btu
Noise: ' - • '
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum perinissible sound levels are based ontfromwhere the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a'hotise at night in a residential zone -it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A) .
Industrial
60 dB(A)
50 dB(A)' •
•65 dB(A) `
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.;
A few sounds are exempt from the noise code, including:
• Warning devices;
• Construction and property maintenance during the daytime hours (7am-lOpm);
• Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
.'i. `,'" •e i ', .
BUILDING 0 i• R OR AU HORIZED AGENT:
Signature:
Print Name:
Jesse Chutich
Mailing Address: 3202 C St NE
H:\Applications\Porms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx
Revised: January 2016
bh
Date:
I Vz drA
Day Telephone: (425) 251-9840
Aburn
City
WA 98002
State Zip
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$285.78
M17-0182 Address: 17640 WEST VALLEY HWY Apn: 2523049017
$285.78
Credit Card Fee
$8.32
Credit Card Fee
R000.369.908.00.00
0.00
$8.32
MECHANICAL
$266.79
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
PERMIT FEE
R000.322.100.00.00
0.00
$180.28
PLAN CHECK FEE
R000.322.102.00.00
0.00
$53.36
TECHNOLOGY FEE
$10.67
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R12901
R000.322.900.04.00
0.00
$10.67
$285.78
Date Paid: Thursday, November 30, 2017
Paid By: JESSE CHUTICH
Pay Method: CREDIT CARD 210364
Printed: Thursday, November 30, 2017 10:46 AM 1 of 1
crSYSTEMS
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
m11i7-01£ 0—
Project:
TARGET 116E1VT 610.0
Type of Inspection:
/hrcHAAlic/L
ANA-1—
Address:
/7690 r Kitts ,4wr,
Date Called:
Special Instructions:
Date Wanted:
a
p.m.
Requester:
Phone No:
Approved per applicable codes. E Corrections required prior to approval.
COMMENTS:
Ok— mOiNificAL F/M-
l�l� M& b i,C*L ef-/
Inspector:
Date: 12 —24 q7
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
STRUCTURAL
CALCULATIONS
Transportation Agent Grid RTU
17640 West Valley Highway
Tukwila, Washington
SEPTEMBER 25, 2017
PREPARED FOR:
Comfort Mechanical
3202 C Street NE
Auburn, Washingt02
•
REVIEWED FOR
COMPLIANCE
APPROVED
DEC 0 8 2017
City of Tukwila
BUILDING DIVISION
PREPARED B ' :
Moore Engineering Group
21902 96th Avenue SE
Snohomish, Washington
Moore
Engineering
Group
M - o 2,
RECEIVED
CITY OF TUKWILA
NOV 3 0 2011
PERMIT CENTER
GENERAL STRUCTURAL NOTES:
1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO
THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION.
2. DESIGN LOADING CRITERIA:
ROOF LIVE LOAD 25 PSF
MECHANICAL UNIT 559 POUNDS
EARTHQUAKE SDS = 0.906
SITE CLASS D to E
WIND 110 MPH, EXPOSURE B
3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION
WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR
SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL
NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION.
4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND
CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING
CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE
VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED
EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON
EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH
THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE
OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO
COMMENCING ANY WORK.
5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND
STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN
COMPLETED IN ACCORDANCE WITH THE DRAWINGS.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE
METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE
COMPLETION OF THE WORK.
7. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL
INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL
STRUCTURAL MEMBERS".
8. CONNECT THE UNITS TO THE METAL CURB ADAPTERS AND THE METAL CURB
ADAPTERS TO THE EXISTING METAL CURBS S WITH A MINIMUM OF (4) #12 SHEET
METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 4" TO 6" FROM
EACH CORNER OF THE UNIT AND THE REMAINING SCREWS ;EQUIDISTANT BETWEEN
THE CORNER SCREWS.
PROTECT DESCRIPTION: The project consists of the replacement of an existing rooftop
mechanical unit.
LOADS: LIVE
DEAD
DEAD + LIVE
WIND
SEISMIC
Roofing and re -roof
1/2' plywood sheathing
2x4 @ 24" on -center
Wood trusses at 8' on -center
Insulation
MEP
Ceiling & Lights
Total Dead
110 mph, Exposure B
Latitude
Longitude
Site Class
SDs (D) =
SDs (E) =
SDS =
EQUIPMENT
Existing RTU -1
Unit 325
Existing Curb 80
Curb Adapter
Total 405 pounds
Dimensions
4.0
1.5
0.7
2.8
1.0
2.0
2.0
14.0
25 PSF
39 PSF
47.445
-122.244
D to E WA DNR
0.953
0.858
0.906
New RTU -1
351
80
128
559 pounds
48"x33"x82" high
Moore
Engineering
Group
PROJECT:
TRANSPORTATION
AGENT GRID RTU
ENGR: KWM
DATE: 9725/ 17
SCALE:
71110
SHEET
9/20/2017
USGS Design Maps Summary Report
User—Specified Input
Design Maps Summary Report
Report Title Transportation Agent Grid RTU
Wed September 20, 2017 23:18:56 UTC
Building Code Reference Document 2012/2015 International Building Code
(which utilizes USGS hazard data available in 2008)
Site Coordinates 47.445°N, 122.244°W
Site Soil Classification Site Class D - "Stiff Soil"
Risk Category 1/11/111
USGS—Provided Output
Ss = 1.429 g
S1= 0.532 g
MS= 1.429 g
SMI = 0.798 g
S„ = 0.953 g
S„ = 0.532 g
For information on how the SS and Si. values above have been calculated from probabilistic (risk -targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
MCER Rtsponse Spetturri
n
to
%
Penod, T <set)
Otvgn Ref*•pai 9 SPeC UM
C..1t7
Perkx.t T (act )
1 k3
Although this information is a product of the U.S. Geological Survey, we provide no Warranty, expressed or implied, as to the
accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge.
https://earthquake.usgs.gov/on2/designmaps/us/summary.php?template=minimal&latitude=47.445&longitude=-122.2448,siteclass=3&riskcategory=0&e... 1/1
9/20/2017 Design Maps Summary Report
JS Design Maps Summary Report
User -Specified Input
Report Title Transportation Agent Grid RTU
Wed September 20, 2017 23:19:10 UTC
Building Code Reference Document 2012/2015. International Building Code
(which utilizes USGS hazard data available in 2008)
Site Coordinates 47.445°N, 122.244°W
Site Class E - "Soft Clay Soil"
I/II/III
Site Soil Classification
Risk Category
USGS-Provided Output
Ss = 1.429 g
Si = 0.532 g
SMs= 1.287 g
SM1 = 1.277 g
Sns = 0.858 g
Sol = 0.852 g
For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
A4irn Respon SP Spectrum
Design Response SpettNjm
PE'f1., r Ks c,)
—
1 1 '1 1 1. 1 1 I
<,i :.'1.� 1.::; 1 1.1..E •..1: ..1i
Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the
accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge.
https://earthquake:usgs.gov/cn2/designmaps/us/summary.php?template=minimal&latitude=47.445&longitude=-122.244&siteciass=48,riskcategory=0&e... 1/1
11
I
Certified Drawing for 2.5T Pkg HP
LI
/ V
Packaged Rooftop Builder 1.49a
<-40
Project: NVCP
Prepared By:
Performance Summary For 2.5T Pkg HP
U807DU17
partNurnber5Olr[-C3O--3
ARI SEER:
Base Unit Dimensions
Unit Length*
Unit VViuth:.' Unit Height
Hoight
Total Operating Weight
14 00
_4x.2 in
_ 32.6 in
51.8 in
351 lb
Unit
Unit Vonaoa-"aoe-Hertc-........... --__.... --............ -....... _---..... -.......... -..... --.... 208-1'*0
Air Discharge* Vertical
Fan Drive DirecteTypa� - -
Actual Airflow' 963 CFM
Site Altitude. _--V ft
Cooling Performance
Condenser Entering Air DB: . yso F
Evaporator Entering Air DB' 80.0 F
Evaporator Entering Air WB' -_ 67.0 F
Entering Air Enthalpy• 31.44 BTU/lb
ao�* F
EvuponemrLemv�gA�DB* -'__-'--_----�_--_'-
Evaporator g Air WB ---.-' 57.8 F
Evaporator Lving AiEnmalp)c24.87 BTU/lb
Net Capacity'_____-_--_2o�4 MBH
Cooling
No\SoosiblCapacity* 20.89 MBH
Total Unit Power Input ---_--'_'--_- 2.48 kW
Coil Bypass Factor' 0.037
Heating Performance
Outdoor 47o F
Entering Air Indoor Coil DB. 70.0 F
LeavingAir Indoor Coil DB: 97.2 F
Total ___ ___ __� _ __ 28,32 MBH
Heating 28.32 MBH
Integrated Moa�ngCopad�' � --'-_-�-------_-'_'-_-__^__
Heating Power 214 kW
Electric
HeaUngCapaoky 7.50 kW
Supply Fan
External o.ao in wg
Options / AccessoriessmocPeonum
Economizer: _............
_-----------_-----____—'_-0zm inw�
Wet Coil' ' _---'_-_-n.nu in wg
Total Application Static (ESP + Unit OumAcc>. 0.45 in wg
Fan Power -'--- _'------u.3n BHP
FanMmorOize.hp' -- _____�_ _1/c
NOTE. ... High Motor Speed, Vert
Electrical Data
197
Minimum Voltage' _'—'-_--_''—_--___--__'_'- �
_--�--_--'---�_'---__---_-_�'263
Maximum- 14.1��
CompressorCompressor LRA. 73
ActualElectric Heater kVV:___-............. -...... ..... .......... .... ............... ____________ ...........................
36.1
E��hcHea�rF�''--__---'--_-__ -- -
0.7
OutdoorFan FLA �u/ --'----'---
.uo
Indoor Fan Mom,FU\�-'--''_--__--_--_--__________________________�____ .
Power Supply MCA' 67.3
Packaged Rooftop Builde1.49a Page 5 of 8
K
0
8
6
0
\
;
0
08
EXISTING CURS LAYOUT
40
to
''"" 14765-4021
7
;(
/
0
/
2
E
t:ieg
\
k |
/A
gari
� \
/#\-
� 5
v'/�
0 41/r f 54k 3 0...
5
444
414
F1.9) t?-
otc �p
�
Pr\
akoTep
10 :-
-4::: .
'Per -13 C.- 3 et01
rcv eal co36 obir
-to ey,, ,i-
Moore
Engineering
Group
PROJECT:
-6A Q2° 'O
ENGR: /6
DATE: Cl/Z.417
SCALE:
SHEET
(411<'ott) q)1/
°'4_,(_-'2°.PY°1-1(-4),§27r)(1-.- z-1 kir
To
Moore
Engineering
Group
PROJECT:
Mg)
- C re -ib
ENGR: /C -J.,
DATE: ef.A751/7
SCALE:
SHEET
SUBMITTAL
Project
NVCP
Date
Thursday, September 07, 2017
REVIEWED FOR
CODE COMPLIANCE
APPROVED
DEC 0 8 2017
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
NOV 3 0 2017
PERIVIIT CENTER
Mil- O)2.
Project: NVCP
Prepared By:
2.5T Pkg HP
09/07/2017
07:18AM
2.5T Pkg HP
Tag Cover Sheet
Unit Report
Certified Drawing
Performance Report
Unit Feature Sheet
Packaged Rooftop Builder 1.49a Page 2 of 8
Project: NVCP
Prepared By:
Unit Report For 2.5T Pkg HP
09/07/2017
07:18AM
Unit Parameters
Unit Model: 50VT-C30---3
Unit Size:.._ _ ............... _ .30 (2-1/2 Tons)
Volts -Phase -Hertz' 208-1-60
Heating Type: Heat Pump
Duct Cfg• Vertical Supply / Vertical Return
Warranty Information
1 year warranty on parts
5 yearwarranty on compressor
No optional warranties were selected.
Dimensions (ft. in.) & Weight (1b.)***
Unit Length:.. 4' 0.1875"
Unit Width: .2' 8.625"
Unit Height. 4' 3.75"
"* Weights and Dimensions are approximate. Weight does not include roof
curbs, unit packaging, field installed accessories or factory
installed options. Approximate dimensions are provided primarily for
shipping purposes. For exact dimensions and weights, refer to appropriate
product data catalog.
Total Operating Weight. 351 Ib
NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods.
Ordering Information
Part Number
Description
Quantity
50VT-C30---3
Rooftop Unit
1
Base Unit
Accessories
CPCRKHTR008A00
240V Crankcase Heater
1
CPHEATER050A00
7.5/9.2/10.0 kW, 208/230/240-1-60 volt, Electric Heater
1
CPECOMZR007B00
ACC -ECONOMIZER VERT 2016 SPP
1
CPRLYKIT001A00
Economizer relay kit for heat pumps
1
Packaged Rooftop Builder 1.49a Page 3 of 8
Certified Drawing for 2.5T Pkg HP
111
111
111
,11,EISEM 7t I] ,IE I ILL1.CTUS
0
LEFT SIDE VIEW
Packaged Rooftop Builder 149a
.T.
•.;!
4,.
6L_:,
).
1
0
LEFT SIDE VIEW
Packaged Rooftop Builder 149a
Microldlet'
0
Date:
7/12/2017
Weights:
471bs/21.32kg
Units:
Part Number:
ECD-SPPSMSA-DWDS
Submitted To: shumphries@airefco.com
Job:
Notes:
Economizer - Standard Leak Economizer, Vertical Orientation, Honeywell W7212 Single Speed Electromechanical Controller, Adjustable Dry
Bulb Sensor, Siemens Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included.
Supply air cover
panel. Shipped on `„ -.
HVAC unit. '-�
j
j -.
2" Filter Rack
\
'` Coil
`'
1" Filters
1 1111
1I,;
'�.�
/%
Filter Access
Door
provided
3/8"
\,;
..
8N
,
i -20 0
Panel for
controls
�Illlp)
��
filter and
access
,
VI
\
�,j
-..
�
\�
11111
-,
III III(/�
•
Replacement panel
shipped with
economizer (some
newer units will
include this panel)
\
:,•Aluminum
"
_
•
N
•
•
-
,
water
entrainment
�
�� �,
filter
Economizer \
outside air
..
�,��"
1�!�i SIDE VIEW
damper Economizer's
p
barometric relief
damper
�� Rainhood with
�� Down Discharge
,.- water entrainment
filter
"Provided.Filters r _-
(2) 10" x 20" x 1"
The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited.
Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248.
0 IVIicr01N1et'
Date:
7/12/2017
Weights:
471bs/21.32kg
Units:
Part Number:
ECD-SPPSMSA-DWDS
Submitted To: shumphries@airefco.com Job: Notes:
Economizer - Standard
Bulb Sensor, Siemens Actuator.
Features:
Leak Economizer, Vertical Orientation, Honeywell W7212 Single Speed Electromechanical Controller, Adjustable Dry
Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included.
installed
trouble-free operation, eliminating slippage and binding associated with standard linkage.
aluminum water entrainment filters in the outside air section.
water run-off.
damper provided.
needed are provided.
Honeywell W7212 controller, mixed (supply) air temperature sensor. OA sensor in description. and spring -return actuator (some include differential return
mounted on economizer.
is field installed in indoor blower fan section.
sensor (included in "-DWZS" models or can be ordered separately - MicroMeti Part No. 9901-0018) is field installed in return duct.
• Includes filter rack. Field
• Gear driven design for
• Includes rainhood with
• Rainhood is sloped for
• Built-in barometric relief
• All hamesses and plugs
Notes:
1. Control systems include
sensor as noted).
2. W7212 controller is factory
3. Mixed (supply) air sensor
4. Differential return enthalpy
The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited.
Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800
Project: NVCP
Prepared By:
Performance Summary For 2.5T Pkg HP
09/07/2017
07:18AM
Part Num bGy:50VT-C3O--3
ARI SEER: -
1*.00
Base Unit Dimensons
Unit Lengthl- -�-� ' ' ' ' ---�' --'-''-� ' ' - -- -� ' ' ' 48.2 in
Unit Width: _- -' -' --'_ --- _-'' - ------' - 328 in
Unit Height. 51.8 in
Total Operating Weight 351 lb
Unit
UohVo8age~Phooe'MoUz. 2084'60
Air Discharge. Vertical
panDhveType: - Direct
Actual Airflow- 963 CFM
Site Altitude. 0 ft
Cooling Performance
ConUonoerEmeringAirDB: --' '- - ----' 96.0 F
Evaporator Entering Air DB.-�------ -�---� ---- -80.0 F
Evaporator Entering Air WB67.0 F
Entering Air Enthalpy 31.44 BTU/lb
Evaporator Leaving Air DB: 58.9 F
Evaporator Leaving Air WB 57.8 F
Evaporator Leaving Air Enthalpy 24.87 BTU/lb
Net Cooling Capacity 28.44 MBH
Net Sensible Capacity 20.89 MBH
Total Unit Power Input 2.48 kW
Coil Bypass Factor 0.037
Heating Performance
Outdoor Ambient Temperature 47.0 F
Entering Air Indoor CoiI DB• -� ' ' ' 70.0 F
Leaving Air Indoor Coil DB: ...... -'-' -''-- - ' --- -� 97.2 F
Total Heating Capacity -' -'-'----� - 28.32 MBH
|ntegogodHoahngCapocity- 28.33 MBH
Heating PoweInput: ----- --__- 2.14 kW
Electric Heating Capacity. 7.50 kW
Unit Leaving Air Temp. 121.8 F
Supply Fan
External Static Pressure. 0.30 in wg
Options / Accessories Static Pressure
Economizer: 0.09 in wg
Wet Coil. 0.06 in wg
Total Application Static (ESP + UndOpts6Auu). 0.49 in wg
Fan Power 0.38 BHP
Fan Motor Size, hp: -1/2
NOTE: High Motor Speed, Vert
Electrical Data
Minimum Voltage: ' 187
Maximum Voltage. 253
CumppaoaurRLA. 14.1
Compressor LRA- 73
Actual Electric Heater kW 7.5
BecthoHeotarFLA- J8]
Outdoor Fan FLA (ea). 0.7
Indoor Fan Motor FLA- 3.8
Power Supply MCA 67.3
Packaged Rooftop Builder 1.49a Page 5 of 8
Project: NVCP
Prepared By:
Performance Summary For 2.5T Pkg HP
09/07/2017
07:18AM
Power Supply MOCP (Fuse or HACR)70
Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage
Acoustics
Sound Rating 75.0 db
Sound Power Levels, db re 10E-12 Watts
Discharge Inlet Outdoor
63 Hz NA NA NA
125 Hz NA NA 52.7
250 Hz NA NA 53.0
500 Hz NA NA 57.9
1000 Hz NA NA 58.7
2000 Hz NA NA 54.8
4000 Hz NA NA 52.2
8000 Hz NA NA 43.2
Advanced Acoustics
Advanced Accoustics Parameters
1. Unit height above ground' 30.0 ft
2. Horizontal distance from unit to receiver ........... ._50.0 ft
3. Receiver height above ground 5.7 ft
4. Height of obstruction: 0.0 ft
5. Horizontal distance from obstruction to receiver 0.0 ft
6. Horizontal distance from unit to obstruction 0.0 ft
Detailed Acoustics Information
Octave Band Center Freq. Hz
63
125
250
500
1k
2k
4k
8k
Overall
A
0.0
52.7
53.0
57.9
58.7
54.8
52.2
43.2
63.5 Lw
B
-
26.2
36.6
44.4
54.7
58.7
56.0
53.2
42.1
62.3 LwA
C
0.0
20.3
20.6
25.5
26.3
22.4
19.8
10.8
31.1 Lp
D
-
26.2
4.2
12.0
22.3
26.3
23.6
20.8
9.7
29.9 LpA
Legend
A Sound Power Levels at Unit's Acoustic Center, Lw
B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA
C Sound Pressure Levels at Specific Distance from Unit, Lp
D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA
Packaged Rooftop Builder 1.49a Page 6 of 8
Project: NVCP
Prepared By:
Performance Summary For 2.57 Pkg HP
09/07/2017
07:18AM
Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI
Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed
that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical
estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be
appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate
an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an
Acoustical Engineer or a person with sound prediction expertise should be consulted.
Packaged Rooftop Builder 1.49a Page 7 of 8
5OVT-C
Comfort^ 14 SEER Single—Packaged Heat Pump
System with :PuronO (R,-41OA) Refrigerant
Single Phase2 5 Nominal Tons:(Sizes 24-60)'
;Three Phase 3-5 Nominal Tons (Sizes 36-60)`
turn to the experts
Product Data
A09034
Fig. 1 - Unit SOVT-C
Single -Packaged Products with Energy -Saving Features and
PuronTO refrigerant.
• Up to 14.5 SEER
• Up to 12.0 EER
• 8.0 HSPF
• ECM Motor -Standard
• Certified to leak 2% or less of nominal air conditioning CFM deliv-
ered when pressurized to 1 -in. W.C. with all present air inlets, air out-
lets, and condensate drain port(s) sealed.
FEATURES/BENEFITS
One-piece Heat Pump unit with optional electric heater, low
installation cost, dependable performance and easy maintenance.
Efficient operation High -efficiency design with SEERs
(Seasonal Energy Efficiency Ratio) of up to 14.5.
Puron Environmentally Sound Refrigerant is Carrier's unique
refrigerant designed to help protect the environment. Puron is an
HFC refrigerant which does not contain chlorine that can harm the
ozone layer. Puron refrigerant is in service in millions of systems,
proving highly reliable, environmentally sound performance.
Easy Installation
Factory -assembled package is a compact, fully self-contained,
heat pump unit that is prewired, pre -piped, and pre -charged for
minimum installation expense. These units are available in a
variety of standard capacity ranges with voltage options to meet
residential and light commercial requirements. Units are
lightweight and install easily on.a rooftop or at ground level. The
high tech composite base eliminates rust problems associated with
ground level applications.
Durable, dependable components
Scroll Compressors are designed for high efficiency. Each
compressor is hermetically sealed against contamination to help
promote longer life and dependable operation. Each compressor
also has vibration isolation to provide quieter operation. All
compressors have internal high pressure and overcurrent
protection.
ECM Motor is standard on all models. Direct -drive, PSC
(Permanent Split Capacitor) condenser -fan motors are designed to
help reduce energy consumption and provide for cooling operation
down to 40°F (4.4°C) outdoor temperature. MotormasterOO II low
ambient kit is available as a field installed accessory.
Innovative Unit Base Design
On the inside a high-tech composite material will not rust and
incorporates a sloped drain pan which improves drainage and helps
inhibit mold, algae and bacterial growth. On the outside metal base
rails provide added stability as well as easier handling and rigging.
Thermostat Controls designed to work as a system with Carrier's
small packaged product.
Refrigerant system is designed to provide dependability. Liquid
filter driers are used to promote clean, unrestricted operation. Each
unit leaves the factory with a full refrigerant charge. Refrigerant
service connections make checking operating pressures easier.
High and Low Pressure Switches provide added reliability for the
compressor.
Indoor and Outdoor coils are computer -designed for optimum
heat transfer and efficiency. The indoor coil is fabricated from
copper tube and aluminum fins and is located inside the unit for
protection against damage. The outdoor coil is internally mounted
on the top tier of the unit.
Low sound ratings ensure a quiet indoor and outdoor
environment with sound ratings as low as 73dBA.
Easy to service cabinets provide easy 3 panel accessibility to
serviceable components during maintenance and installation. The
base with integrated drain pan provides easy ground level
installation with mounting pad. A nesting feature ensures a
positive basepan to roof curb seal when the unit is roof mounted. A
convenient 3/4 -in. wide perimeter flange makes frame mounting
on a rooftop easy.
Convertible duct configuration
Unit is designed for use in either downflow or horizontal
applications. Each unit is converted from horizontal to downflow
with the two standard duct covers. Downflow operation is easily
provided in the field to allow vertical ductwork connections. The
basepan utilizes seals on the bottom openings to ensure a positive
seal in the vertical airflow mode.
Cabinets are constructed of heavyduty, phosphated, zinc -coated
prepainted steel capable of withstanding 500 hours in salt spray.
Interior surfaces of the evaporator and electric heater compartments
are insulated with cleanable semi-rigid insulation hoard, which
keeps the conditioned air from being affected by the outdoor
ambient temperature and provides improved indoor air quality.
(Conforms to American Society of Heating, Refrigeration and Air
1
Conditioning Engineers No. 62P.) The sloped drain pan minimizes
standing water in the drain. An external drain is provided.
Short -Cycling protection for the compressor is incorporated into
our defrost control board ensuring a five minute delay (+/-2
minutes) before restarting compressor after shutdown for any
reason.
TABLE OF CONTENTS
FEATURES/BENEFITS 1
MODEL NUMBER NOMENCLATURE 2
AHRI CAPACITIES 3
PHYSICAL DATA 4
OPTIONS AND ACCESSORIES 5
ROOF CURB ACCESSORY DIMENSIONS 6
BASE UNIT DIMENSIONS 7-8
SELECTION PROCEDURE 10
PERFORMANCE DATA 11-24
TYPICAL PIPING AND WIRING 25
APPLICATION DATA 26
ELECTRICAL DATA '78
TYPICAL WIRING SCHEMATICS 30-35
CONTROLS 36
GUIDE SPECIFICATIONS 37-38
MODEL NUMBER NOMENCLATURE
50VT
C 24
Type of Unit
50VT - Single Packaged
Heal Pump
System
N/A
Major Series
Nominal Cooling Capacity
24 - 2.0 Tons
30 - 2.5 Tons
36 - 3.0 Tons
42 - 3.5 Tons
48 - 4.0 Tons
60 - 5.0 Tons
N/A
c
LISTED
US
3 1
Options
LT - 2% air leakage, tin plated indoor coil hairpins
and louver metal outdoor grille.
TP - Base unit with tin plated indoor coil hairpins
(Single Phase ;Only)
See Price Page for full list of factory options.
Only used 4 ordering an option
Minor Series
Electrical Supply
3 - 208/230-1 - 60
5 - 208/230-3-60
6 - 460- 3- 60
.4i CERTIFIO ti'k.
Use of the AHRI Certified
TM Mark indicates a
manufacturer's
participation in the
program For verification
of certification for individual
products, go to
www.ahridireclory.org.
ASIMAE
COMPLIANT.
z
O
Lu z 0
ce
o
U a
o z
z
Q
a
a
EXISTING CURB LAYOUT
Hea
0O
20
zo
(0
en
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M17-0182 DATE: 11/30/17
" PROJECT NAME: TARGET AGENT GRID
SITE ADDRESS: 17640 WEST VALLEY HWY
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
ars tw& YOi
Building Division
Public Works
n
Fire Prevention
Structural
Planning Division n
❑ Permit Coordinator
Tr]I
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 12/05/17
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 01/02/18
Approved
Corrections Required
❑ Approved with Conditions ❑
❑ Denied ❑
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials:
12/18/2013
COMFORT MECHANICAL INC
Washington State Department of
Labor & Industries
Hoine Lsspano1 Contact.
Safety & Health Claims & Insurance
Page 1 of 2
Search L&I
A -Z Hrdex I-lelp
Workplace Rights Trades & Licensing
COMFORT MECHANICAL INC
Owner or tradesperson
Principals
JACKSON, SHIRLEY A, PRESIDENT
JACKSON, HERB J, VICE PRESIDENT
Doing business as
COMFORT MECHANICAL INC
WA UBI No.
601 954 041
3202 C ST NE
AUBURN, WA 98002
425-251-9840
KING County
Business type
Corporation
Governing persons
HERB
J
JACKSON
SHIRLEY A JACKSON;
License
Verify the contractors active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
HeatingNent/Air-Conditioning and Refrig
(HVAC/R)
License no.
COMFOMI015LA
Effective — expiration
06/01/1999— 04/25/2018
Bond
Lexon Ins Co
Bond account no.
9815017
Active.
Meets current requirements.
$6,000.00
Received by L&I Effective date
06/04/2012 06/01/2012
Expiration date
Until Canceled
Bond history
Insurance
AMCO Ins Co
Policy no.
AC P3008276478
Received by L&I
05/24/2017
Insurance history
Savings
$1,000,000.00
Effective date
06/01/2017
Expiration date
06/01/2018
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 12/8/2017
PARCEL
Parcel Number
252304-9017
Name
TERRENO 17600 WVH LLC
Site Address
17600 WEST VALLEY HWY 98188
ILegal
S329.85 FT OF GL 7 LY BET PST & P R/W & CO RD LESS ST HVVY
PROJECT DESCRIPTION:
1. REPLACE (1) 2.5 -TON ROOF MOUNTED PACKAGED HEAT
PUMP WITH NEW 2.5 -TON ROOF MOUNTED PACKAGED
HEAT PUMP WITH ECONOMIZER.
GENERAL NOTES:
1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH
PARTIAL COOLING AND MULTIPLE COOLING STAGES.
2. NO MODIFICATIONS TO EXISTING STRUCTURE PER
STRUCTURAL CALCS.
3 ANCHORAGE: (3) #10 SMS PER SIDE.
4. THERMOSTAT TO PROVIDE MINIMUM 50 DEADBAND.
5.7 -DAY PROGRAMMABLE THERMOSTAT WITH LOCKOUT.
6. INSTALL GFCI OUTLET WITHIN 25' OF UNIT.
7. ROUTE CONDENSATE TO SPLASH BLOCK ON ROOF.
8. PROVIDE COMMISSIONING REPORT.
HVAC Equipment Schedule (New)
#
Brand
Model
Ton 1
Total CFM
Cap. Heat
Cap. Cool
SEER
Weight
Sound(bels)
Location
RTU -1
Carrier
50VT-C30
2.5 1
963
28,000
28,000
14
351
75
Roof
Project
Briefly
the
text
ill
This
provisions
MECH-SUM,
Energy
Description
describe mechanical systems In
box provided
Total Bldg Performance (TBP)
path includes all mandatory
per C401.2 Option 2.
MECH-CHK and 0407
Analysis forms required.
n
,__,New Building DBuiithng Addition DTenant Improvement
REPLACE (1) 2.5 -TON ROOF MOUNTED PACKAGED HEAT PUMP
El
System Retrofit
WITH NEW LIKE UNIT.
No System Changes
Design Load Calculations
1 Load calculation summary
Provide design load calculations for all
ventilating needs. If a load calculation summary
compliance information then the MECH-LOAD-CALC
•
mechanical
MECH-LOAD-CALC Form
systems and equipment serving the building heating, cooling or
is provided with the permit documents that includes all applicable
form is not required.
Mechanical Schedules
Fi Mechanical Plans
Indicate location of equipment compliance
however, include on plans all applicable
1
compliance
MECH-EQ Forms (TBD)
information. If provided on plans then MECH-EQ forms am not required,
information listed in MECH-EQ tables.
Dedicated Outdoor .Air
System Requirements arid
High Efficiency VAV
Alternate
•
All
not
•
1
DOAS
occupied,
require
•
•
ill
DOAS
DOAS
1
Is required per C403.6 effective July 1, 2017 (office, retail, education, library and fire station occupandes)
conditioned areas shall be served by a DOAS that delivers required ventilation air In a manner that does
space conditioning fan operation. Space conditioning fans cycled off when no heating or cooling Is required
Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, Exception 1)
Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS (C403.6, Exception
2)
included in project, although not required (occupancy not office, retail education, library or fire station)
related allowances Included in project:
Prescriptive vertical fenestration maximum area allowance increased to 40% per 0402.4.1.4 with 100% of
conditioned floor area In building served by DOAS.
Exception to air economizer per C403.3 Exception 1, Include MECH7ECONO form.
Fan Power
El
is
Project includes HVAC air distribution systems that provide heating and/or cooling
If yes, provide a MECH-FANSYS -SUM form.
For one or more systems, the total fan motor nameplate hp of all fans In HVAC system exceeds 5hp.
/f yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold.
Refer to Section c403.2.11 and MECH-FANSYS-DOC for requirements and exceptions.
HVAC Ilydronic Systems
1
1
Hydronic chilled water
HydronIc heating water
0
1
Water -loop heat pump
Geothermal
..,
No hydronic systems
C406 Additional Efficiency
Options - Mechanical
•
1
1
0406.2 More efficient HVAC equipment and fan systems
Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat
pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than
minimum requirements. All stand alone supply, retum, and exhaust fans over 1hp must have FEQ 71 and must be
selected within 10% of maximum total or static pressure.
0406.6 Dedicated outdoor air system (DOAS)
Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a
manner that does not require space conditioning fan operation.
C406.7 Reduced energy In service water heating
Requires 90% of tloor area be in occupancy types listed in C406.7.1 and that 60% of annual hot water energy use be
provided by heat pump, waste heat recovery or solar water -heating systems.
Note 1- Constant Volume (CV), Variable Air Volume (VAV), or HospitaULab CV system that qualifies for VAV budget per C403.2.11.1 Exception 1.
Single zone VAV systems shall comply as CV.
Note 2 - Describe system type and list al! fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. Include
all supply, retum/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered
terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak
conditions.
Note 3- Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system.
Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes),
or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No)
MECH-FANSYS Forms
A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan RECEI
System Form) to generate an additional form Added forms can be deleted with button in cell E32 of the added form. CITY OF T
RiU-1
30'1
I I
TRANSPORT AGENT GRID 1.
ROOF PLAN - NO SCALE
REVISIONS
No changes shall ho made to the Scope
of work without prior approval of
Tukwila Boilding Division -
NOTE: RevLsons Will require a new plan submittal
and may ins:ude additional plan review fees
2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1
-,- mu -
Mechanical Summary MECH-SUM
Date 11/7/2017
2015 Washington State Energy Code Compliance
Forms for Commercial Buildin. s includin. R2 & R3 over 3 stories and all R1 Revised January 2017
Project Information
Project Title: Transport Agent Grid
Date 11/7/2017
System Total
Nameplate HP
(Note 3)
Applicant Information. Provide contact information for Individual who can respond to
inquiries about compliance form Information provided.
For Building Dept. Use
CV
Company Name: COMFORT MECHANICAL.
0.5
No
Company Address: 3202 C ST NE AUBURN, WA 98002
Applicant Name JESSE CHUTICH
Applicant Phone: 425-251-9840
Project
Briefly
the
text
ill
This
provisions
MECH-SUM,
Energy
Description
describe mechanical systems In
box provided
Total Bldg Performance (TBP)
path includes all mandatory
per C401.2 Option 2.
MECH-CHK and 0407
Analysis forms required.
n
,__,New Building DBuiithng Addition DTenant Improvement
REPLACE (1) 2.5 -TON ROOF MOUNTED PACKAGED HEAT PUMP
El
System Retrofit
WITH NEW LIKE UNIT.
No System Changes
Design Load Calculations
1 Load calculation summary
Provide design load calculations for all
ventilating needs. If a load calculation summary
compliance information then the MECH-LOAD-CALC
•
mechanical
MECH-LOAD-CALC Form
systems and equipment serving the building heating, cooling or
is provided with the permit documents that includes all applicable
form is not required.
Mechanical Schedules
Fi Mechanical Plans
Indicate location of equipment compliance
however, include on plans all applicable
1
compliance
MECH-EQ Forms (TBD)
information. If provided on plans then MECH-EQ forms am not required,
information listed in MECH-EQ tables.
Dedicated Outdoor .Air
System Requirements arid
High Efficiency VAV
Alternate
•
All
not
•
1
DOAS
occupied,
require
•
•
ill
DOAS
DOAS
1
Is required per C403.6 effective July 1, 2017 (office, retail, education, library and fire station occupandes)
conditioned areas shall be served by a DOAS that delivers required ventilation air In a manner that does
space conditioning fan operation. Space conditioning fans cycled off when no heating or cooling Is required
Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, Exception 1)
Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS (C403.6, Exception
2)
included in project, although not required (occupancy not office, retail education, library or fire station)
related allowances Included in project:
Prescriptive vertical fenestration maximum area allowance increased to 40% per 0402.4.1.4 with 100% of
conditioned floor area In building served by DOAS.
Exception to air economizer per C403.3 Exception 1, Include MECH7ECONO form.
Fan Power
El
is
Project includes HVAC air distribution systems that provide heating and/or cooling
If yes, provide a MECH-FANSYS -SUM form.
For one or more systems, the total fan motor nameplate hp of all fans In HVAC system exceeds 5hp.
/f yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold.
Refer to Section c403.2.11 and MECH-FANSYS-DOC for requirements and exceptions.
HVAC Ilydronic Systems
1
1
Hydronic chilled water
HydronIc heating water
0
1
Water -loop heat pump
Geothermal
..,
No hydronic systems
C406 Additional Efficiency
Options - Mechanical
•
1
1
0406.2 More efficient HVAC equipment and fan systems
Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat
pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than
minimum requirements. All stand alone supply, retum, and exhaust fans over 1hp must have FEQ 71 and must be
selected within 10% of maximum total or static pressure.
0406.6 Dedicated outdoor air system (DOAS)
Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a
manner that does not require space conditioning fan operation.
C406.7 Reduced energy In service water heating
Requires 90% of tloor area be in occupancy types listed in C406.7.1 and that 60% of annual hot water energy use be
provided by heat pump, waste heat recovery or solar water -heating systems.
CO
PM
ermit No, \1117.
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted coda or ordnance. Receipt
of approved Field Copy and cond' s is acknowledged:
By:
Date: 12-A fX-z
City of Tukwila
BUILDING DIVISION
2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stones and all R1
Mechanical Fan System Power Allowance
MECH-FANSYS-SUM
015 Washjnaton State Enerav Code Com !lance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January2ol7
— '
Project Title: Transport Agent Grid
Date 11/7/2017
For Building Dept. Use
HVAC Air Distribution System Schedule
List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve.
System or
Primary Supply
Fan ID
Speed Control
(Note 1)
Description
(Note 2)
System Total
Nameplate HP
(Note 3)
Fan Power
Calculation
Required
(Note 4)
RTU -1
CV
HEAT PUMP
0.5
No
Note 1- Constant Volume (CV), Variable Air Volume (VAV), or HospitaULab CV system that qualifies for VAV budget per C403.2.11.1 Exception 1.
Single zone VAV systems shall comply as CV.
Note 2 - Describe system type and list al! fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. Include
all supply, retum/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered
terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak
conditions.
Note 3- Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system.
Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes),
or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No)
MECH-FANSYS Forms
A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan RECEI
System Form) to generate an additional form Added forms can be deleted with button in cell E32 of the added form. CITY OF T
REVISIONS
z.
0
DATE :
SCALE
DRAWN:
CHECKED:
I SPPi
RE(
RATE PERMIT
.UIRED FOR:
Mechanical
Electrical
Plumbing
Gs Piping
y of Tukwila
DivisioN
VED
KWILA
NOV 30 2017 -
PERMIT CENTER