HomeMy WebLinkAboutPermit M17-0182 - TARGET AGENT GRID - ROOFTOP HEAT PUMPTARGET AGENT GRID 17640 WEST VALLEY HWY M17-0182 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2523049017 17640 WEST VALLEY HWY Project Name: TARGET AGENT GRID MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: M 17-0182 12/11/2017 6/9/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TERRENO 17600 WVH LLC 101 MONTGOMERY ST #200, SAN FRANCISCO, WA, 94104 JESSE CHUTICH 3202 C ST NE , AUBURN, WA, 98002 COMFORT MECHANICAL INC (CONSTRUCT) 3202 C ST NE , AUBURN, WA, 98002 COMFOM1015LA Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: 4/25/2018 DESCRIPTION OF WORK: REPLACE (1) 2.5 -TON ROOFTOP HEAT PUMP LIKE FOR LIKE Valuation of Work: $5,751.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $285.78 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: RENTON Sewer District: RENTON Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: /� 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: it PA 2017 2017 2017 2015 Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: �JeSS.0 Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. r1/41 ( 1'0 t Project No. Date Application Accepted: Date Application Expires: s',– 30—( V (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION / ' l King Co Assessor's Tax No.: Zs -230y -10/ 7 Site Address: / 76, yo \✓es � vo( / (e y �l w y Suite Number: Tenant Name: q t c1 ¢, �- Iq c�t n i' G r i d ! PROPERTY OWNER Name: Jesse Chutich Name: e,rre,1)® ( City: Auburn State: WA Zip: 98002 Address: J moo v41! ya 1-1g... City: T�l k W 1 State:(! Zip. "lg 1 b �p v CONTACT PERSON – person receiving all project communication Name: Jesse Chutich Address: 3202 C St NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Email: jesse@comfortmech.com Floor: New Tenant: ❑ Yes 0 MECHANICAL CONTRACTOR INFORMATION Company Name: Comfort Mechanical Inc. Address: 3202 C St NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Contr Reg No.: COMFOM1015LA Exp Date: 04/25/2018 Tukwila Business License No.: BUS -0993365 Valuation of project (contractor's bid price): $ S, 7 ( Describe the scope of work in detail: Re?ll►C.As 0) 1,S- -lair roof fop I- e t p t eke for (;ke Use: Residential: New Commercial: New Fuel Type: Electric Replacement Replacement Gas ❑ Other: H:\Applications\Fortes-Applications On Line \2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh E Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type . Qty Furnace <1OOk btu 1 Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) . <10,000 cfin 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) . Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) . Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+hp/1,750,000 btu Noise: ' - • ' Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum perinissible sound levels are based ontfromwhere the sound is created and where the sound is heard. Additionally, if sound can be heard from within a'hotise at night in a residential zone -it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) . Industrial 60 dB(A) 50 dB(A)' • •65 dB(A) ` 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.; A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. .'i. `,'" •e i ', . BUILDING 0 i• R OR AU HORIZED AGENT: Signature: Print Name: Jesse Chutich Mailing Address: 3202 C St NE H:\Applications\Porms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Date: I Vz drA Day Telephone: (425) 251-9840 Aburn City WA 98002 State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $285.78 M17-0182 Address: 17640 WEST VALLEY HWY Apn: 2523049017 $285.78 Credit Card Fee $8.32 Credit Card Fee R000.369.908.00.00 0.00 $8.32 MECHANICAL $266.79 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $180.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $53.36 TECHNOLOGY FEE $10.67 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12901 R000.322.900.04.00 0.00 $10.67 $285.78 Date Paid: Thursday, November 30, 2017 Paid By: JESSE CHUTICH Pay Method: CREDIT CARD 210364 Printed: Thursday, November 30, 2017 10:46 AM 1 of 1 crSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 m11i7-01£ 0— Project: TARGET 116E1VT 610.0 Type of Inspection: /hrcHAAlic/L ANA-1— Address: /7690 r Kitts ,4wr, Date Called: Special Instructions: Date Wanted: a p.m. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Ok— mOiNificAL F/M- l�l� M& b i,C*L ef-/ Inspector: Date: 12 —24 q7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. STRUCTURAL CALCULATIONS Transportation Agent Grid RTU 17640 West Valley Highway Tukwila, Washington SEPTEMBER 25, 2017 PREPARED FOR: Comfort Mechanical 3202 C Street NE Auburn, Washingt02 • REVIEWED FOR COMPLIANCE APPROVED DEC 0 8 2017 City of Tukwila BUILDING DIVISION PREPARED B ' : Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington Moore Engineering Group M - o 2, RECEIVED CITY OF TUKWILA NOV 3 0 2011 PERMIT CENTER GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT 559 POUNDS EARTHQUAKE SDS = 0.906 SITE CLASS D to E WIND 110 MPH, EXPOSURE B 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 8. CONNECT THE UNITS TO THE METAL CURB ADAPTERS AND THE METAL CURB ADAPTERS TO THE EXISTING METAL CURBS S WITH A MINIMUM OF (4) #12 SHEET METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 4" TO 6" FROM EACH CORNER OF THE UNIT AND THE REMAINING SCREWS ;EQUIDISTANT BETWEEN THE CORNER SCREWS. PROTECT DESCRIPTION: The project consists of the replacement of an existing rooftop mechanical unit. LOADS: LIVE DEAD DEAD + LIVE WIND SEISMIC Roofing and re -roof 1/2' plywood sheathing 2x4 @ 24" on -center Wood trusses at 8' on -center Insulation MEP Ceiling & Lights Total Dead 110 mph, Exposure B Latitude Longitude Site Class SDs (D) = SDs (E) = SDS = EQUIPMENT Existing RTU -1 Unit 325 Existing Curb 80 Curb Adapter Total 405 pounds Dimensions 4.0 1.5 0.7 2.8 1.0 2.0 2.0 14.0 25 PSF 39 PSF 47.445 -122.244 D to E WA DNR 0.953 0.858 0.906 New RTU -1 351 80 128 559 pounds 48"x33"x82" high Moore Engineering Group PROJECT: TRANSPORTATION AGENT GRID RTU ENGR: KWM DATE: 9725/ 17 SCALE: 71110 SHEET 9/20/2017 USGS Design Maps Summary Report User—Specified Input Design Maps Summary Report Report Title Transportation Agent Grid RTU Wed September 20, 2017 23:18:56 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.445°N, 122.244°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category 1/11/111 USGS—Provided Output Ss = 1.429 g S1= 0.532 g MS= 1.429 g SMI = 0.798 g S„ = 0.953 g S„ = 0.532 g For information on how the SS and Si. values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCER Rtsponse Spetturri n to % Penod, T <set) Otvgn Ref*•pai 9 SPeC UM C..1t7 Perkx.t T (act ) 1 k3 Although this information is a product of the U.S. Geological Survey, we provide no Warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. https://earthquake.usgs.gov/on2/designmaps/us/summary.php?template=minimal&latitude=47.445&longitude=-122.2448,siteclass=3&riskcategory=0&e... 1/1 9/20/2017 Design Maps Summary Report JS Design Maps Summary Report User -Specified Input Report Title Transportation Agent Grid RTU Wed September 20, 2017 23:19:10 UTC Building Code Reference Document 2012/2015. International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.445°N, 122.244°W Site Class E - "Soft Clay Soil" I/II/III Site Soil Classification Risk Category USGS-Provided Output Ss = 1.429 g Si = 0.532 g SMs= 1.287 g SM1 = 1.277 g Sns = 0.858 g Sol = 0.852 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. A4irn Respon SP Spectrum Design Response SpettNjm PE'f1., r Ks c,) — 1 1 '1 1 1. 1 1 I <,i :.'1.� 1.::; 1 1.1..E •..1: ..1i Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. https://earthquake:usgs.gov/cn2/designmaps/us/summary.php?template=minimal&latitude=47.445&longitude=-122.244&siteciass=48,riskcategory=0&e... 1/1 11 I Certified Drawing for 2.5T Pkg HP LI / V Packaged Rooftop Builder 1.49a <-40 Project: NVCP Prepared By: Performance Summary For 2.5T Pkg HP U807DU17 partNurnber5Olr[-C3O--3 ARI SEER: Base Unit Dimensions Unit Length* Unit VViuth:.' Unit Height Hoight Total Operating Weight 14 00 _4x.2 in _ 32.6 in 51.8 in 351 lb Unit Unit Vonaoa-"aoe-Hertc-........... --__.... --............ -....... _---..... -.......... -..... --.... 208-1'*0 Air Discharge* Vertical Fan Drive DirecteTypa� - - Actual Airflow' 963 CFM Site Altitude. _--V ft Cooling Performance Condenser Entering Air DB: . yso F Evaporator Entering Air DB' 80.0 F Evaporator Entering Air WB' -_ 67.0 F Entering Air Enthalpy• 31.44 BTU/lb ao�* F EvuponemrLemv�gA�DB* -'__-'--_----�_--_'- Evaporator g Air WB ---.-' 57.8 F Evaporator Lving AiEnmalp)c24.87 BTU/lb Net Capacity'_____-_--_2o�4 MBH Cooling No\SoosiblCapacity* 20.89 MBH Total Unit Power Input ---_--'_'--_- 2.48 kW Coil Bypass Factor' 0.037 Heating Performance Outdoor 47o F Entering Air Indoor Coil DB. 70.0 F LeavingAir Indoor Coil DB: 97.2 F Total ___ ___ __� _ __ 28,32 MBH Heating 28.32 MBH Integrated Moa�ngCopad�' � --'-_-�-------_-'_'-_-__^__ Heating Power 214 kW Electric HeaUngCapaoky 7.50 kW Supply Fan External o.ao in wg Options / AccessoriessmocPeonum Economizer: _............ _-----------_-----____—'_-0zm inw� Wet Coil' ' _---'_-_-n.nu in wg Total Application Static (ESP + Unit OumAcc>. 0.45 in wg Fan Power -'--- _'------u.3n BHP FanMmorOize.hp' -- _____�_ _1/c NOTE. ... High Motor Speed, Vert Electrical Data 197 Minimum Voltage' _'—'-_--_''—_--___--__'_'- � _--�--_--'---�_'---__---_-_�'263 Maximum- 14.1�� CompressorCompressor LRA. 73 ActualElectric Heater kVV:___-............. -...... ..... .......... .... ............... ____________ ........................... 36.1 E��hcHea�rF�''--__---'--_-__ -- - 0.7 OutdoorFan FLA �u/ --'----'--- .uo Indoor Fan Mom,FU\�-'--''_--__--_--_--__________________________�____ . Power Supply MCA' 67.3 Packaged Rooftop Builde1.49a Page 5 of 8 K 0 8 6 0 \ ; 0 08 EXISTING CURS LAYOUT 40 to ''"" 14765-4021 7 ;( / 0 / 2 E t:ieg \ k | /A gari � \ /#\- � 5 v'/� 0 41/r f 54k 3 0... 5 444 414 F1.9) t?- otc �p � Pr\ akoTep 10 :- -4::: . 'Per -13 C.- 3 et01 rcv eal co36 obir -to ey,, ,i- Moore Engineering Group PROJECT: -6A Q2° 'O ENGR: /6 DATE: Cl/Z.417 SCALE: SHEET (411<'ott) q)1/ °'4_,(_-'2°.PY°1-1(-4),§27r)(1-.- z-1 kir To Moore Engineering Group PROJECT: Mg) - C re -ib ENGR: /C -J., DATE: ef.A751/7 SCALE: SHEET SUBMITTAL Project NVCP Date Thursday, September 07, 2017 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 8 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 3 0 2017 PERIVIIT CENTER Mil- O)2. Project: NVCP Prepared By: 2.5T Pkg HP 09/07/2017 07:18AM 2.5T Pkg HP Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.49a Page 2 of 8 Project: NVCP Prepared By: Unit Report For 2.5T Pkg HP 09/07/2017 07:18AM Unit Parameters Unit Model: 50VT-C30---3 Unit Size:.._ _ ............... _ .30 (2-1/2 Tons) Volts -Phase -Hertz' 208-1-60 Heating Type: Heat Pump Duct Cfg• Vertical Supply / Vertical Return Warranty Information 1 year warranty on parts 5 yearwarranty on compressor No optional warranties were selected. Dimensions (ft. in.) & Weight (1b.)*** Unit Length:.. 4' 0.1875" Unit Width: .2' 8.625" Unit Height. 4' 3.75" "* Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Total Operating Weight. 351 Ib NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50VT-C30---3 Rooftop Unit 1 Base Unit Accessories CPCRKHTR008A00 240V Crankcase Heater 1 CPHEATER050A00 7.5/9.2/10.0 kW, 208/230/240-1-60 volt, Electric Heater 1 CPECOMZR007B00 ACC -ECONOMIZER VERT 2016 SPP 1 CPRLYKIT001A00 Economizer relay kit for heat pumps 1 Packaged Rooftop Builder 1.49a Page 3 of 8 Certified Drawing for 2.5T Pkg HP 111 111 111 ,11,EISEM 7t I] ,IE I ILL1.CTUS 0 LEFT SIDE VIEW Packaged Rooftop Builder 149a .T. •.;! 4,. 6L_:, ). 1 0 LEFT SIDE VIEW Packaged Rooftop Builder 149a Microldlet' 0 Date: 7/12/2017 Weights: 471bs/21.32kg Units: Part Number: ECD-SPPSMSA-DWDS Submitted To: shumphries@airefco.com Job: Notes: Economizer - Standard Leak Economizer, Vertical Orientation, Honeywell W7212 Single Speed Electromechanical Controller, Adjustable Dry Bulb Sensor, Siemens Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. Supply air cover panel. Shipped on `„ -. HVAC unit. '-� j j -. 2" Filter Rack \ '` Coil `' 1" Filters 1 1111 1I,; '�.� /% Filter Access Door provided 3/8" \,; .. 8N , i -20 0 Panel for controls �Illlp) �� filter and access , VI \ �,j -.. � \� 11111 -, III III(/� • Replacement panel shipped with economizer (some newer units will include this panel) \ :,•Aluminum " _ • N • • - , water entrainment � �� �, filter Economizer \ outside air .. �,��" 1�!�i SIDE VIEW damper Economizer's p barometric relief damper �� Rainhood with �� Down Discharge ,.- water entrainment filter "Provided.Filters r _- (2) 10" x 20" x 1" The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248. 0 IVIicr01N1et' Date: 7/12/2017 Weights: 471bs/21.32kg Units: Part Number: ECD-SPPSMSA-DWDS Submitted To: shumphries@airefco.com Job: Notes: Economizer - Standard Bulb Sensor, Siemens Actuator. Features: Leak Economizer, Vertical Orientation, Honeywell W7212 Single Speed Electromechanical Controller, Adjustable Dry Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. installed trouble-free operation, eliminating slippage and binding associated with standard linkage. aluminum water entrainment filters in the outside air section. water run-off. damper provided. needed are provided. Honeywell W7212 controller, mixed (supply) air temperature sensor. OA sensor in description. and spring -return actuator (some include differential return mounted on economizer. is field installed in indoor blower fan section. sensor (included in "-DWZS" models or can be ordered separately - MicroMeti Part No. 9901-0018) is field installed in return duct. • Includes filter rack. Field • Gear driven design for • Includes rainhood with • Rainhood is sloped for • Built-in barometric relief • All hamesses and plugs Notes: 1. Control systems include sensor as noted). 2. W7212 controller is factory 3. Mixed (supply) air sensor 4. Differential return enthalpy The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 Project: NVCP Prepared By: Performance Summary For 2.5T Pkg HP 09/07/2017 07:18AM Part Num bGy:50VT-C3O--3 ARI SEER: - 1*.00 Base Unit Dimensons Unit Lengthl- -�-� ' ' ' ' ---�' --'-''-� ' ' - -- -� ' ' ' 48.2 in Unit Width: _- -' -' --'_ --- _-'' - ------' - 328 in Unit Height. 51.8 in Total Operating Weight 351 lb Unit UohVo8age~Phooe'MoUz. 2084'60 Air Discharge. Vertical panDhveType: - Direct Actual Airflow- 963 CFM Site Altitude. 0 ft Cooling Performance ConUonoerEmeringAirDB: --' '- - ----' 96.0 F Evaporator Entering Air DB.-�------ -�---� ---- -80.0 F Evaporator Entering Air WB67.0 F Entering Air Enthalpy 31.44 BTU/lb Evaporator Leaving Air DB: 58.9 F Evaporator Leaving Air WB 57.8 F Evaporator Leaving Air Enthalpy 24.87 BTU/lb Net Cooling Capacity 28.44 MBH Net Sensible Capacity 20.89 MBH Total Unit Power Input 2.48 kW Coil Bypass Factor 0.037 Heating Performance Outdoor Ambient Temperature 47.0 F Entering Air Indoor CoiI DB• -� ' ' ' 70.0 F Leaving Air Indoor Coil DB: ...... -'-' -''-- - ' --- -� 97.2 F Total Heating Capacity -' -'-'----� - 28.32 MBH |ntegogodHoahngCapocity- 28.33 MBH Heating PoweInput: ----- --__- 2.14 kW Electric Heating Capacity. 7.50 kW Unit Leaving Air Temp. 121.8 F Supply Fan External Static Pressure. 0.30 in wg Options / Accessories Static Pressure Economizer: 0.09 in wg Wet Coil. 0.06 in wg Total Application Static (ESP + UndOpts6Auu). 0.49 in wg Fan Power 0.38 BHP Fan Motor Size, hp: -1/2 NOTE: High Motor Speed, Vert Electrical Data Minimum Voltage: ' 187 Maximum Voltage. 253 CumppaoaurRLA. 14.1 Compressor LRA- 73 Actual Electric Heater kW 7.5 BecthoHeotarFLA- J8] Outdoor Fan FLA (ea). 0.7 Indoor Fan Motor FLA- 3.8 Power Supply MCA 67.3 Packaged Rooftop Builder 1.49a Page 5 of 8 Project: NVCP Prepared By: Performance Summary For 2.5T Pkg HP 09/07/2017 07:18AM Power Supply MOCP (Fuse or HACR)70 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating 75.0 db Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 52.7 250 Hz NA NA 53.0 500 Hz NA NA 57.9 1000 Hz NA NA 58.7 2000 Hz NA NA 54.8 4000 Hz NA NA 52.2 8000 Hz NA NA 43.2 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground' 30.0 ft 2. Horizontal distance from unit to receiver ........... ._50.0 ft 3. Receiver height above ground 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 0.0 52.7 53.0 57.9 58.7 54.8 52.2 43.2 63.5 Lw B - 26.2 36.6 44.4 54.7 58.7 56.0 53.2 42.1 62.3 LwA C 0.0 20.3 20.6 25.5 26.3 22.4 19.8 10.8 31.1 Lp D - 26.2 4.2 12.0 22.3 26.3 23.6 20.8 9.7 29.9 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.49a Page 6 of 8 Project: NVCP Prepared By: Performance Summary For 2.57 Pkg HP 09/07/2017 07:18AM Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.49a Page 7 of 8 5OVT-C Comfort^ 14 SEER Single—Packaged Heat Pump System with :PuronO (R,-41OA) Refrigerant Single Phase2 5 Nominal Tons:(Sizes 24-60)' ;Three Phase 3-5 Nominal Tons (Sizes 36-60)` turn to the experts Product Data A09034 Fig. 1 - Unit SOVT-C Single -Packaged Products with Energy -Saving Features and PuronTO refrigerant. • Up to 14.5 SEER • Up to 12.0 EER • 8.0 HSPF • ECM Motor -Standard • Certified to leak 2% or less of nominal air conditioning CFM deliv- ered when pressurized to 1 -in. W.C. with all present air inlets, air out- lets, and condensate drain port(s) sealed. FEATURES/BENEFITS One-piece Heat Pump unit with optional electric heater, low installation cost, dependable performance and easy maintenance. Efficient operation High -efficiency design with SEERs (Seasonal Energy Efficiency Ratio) of up to 14.5. Puron Environmentally Sound Refrigerant is Carrier's unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems, proving highly reliable, environmentally sound performance. Easy Installation Factory -assembled package is a compact, fully self-contained, heat pump unit that is prewired, pre -piped, and pre -charged for minimum installation expense. These units are available in a variety of standard capacity ranges with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on.a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Durable, dependable components Scroll Compressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection. ECM Motor is standard on all models. Direct -drive, PSC (Permanent Split Capacitor) condenser -fan motors are designed to help reduce energy consumption and provide for cooling operation down to 40°F (4.4°C) outdoor temperature. MotormasterOO II low ambient kit is available as a field installed accessory. Innovative Unit Base Design On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Thermostat Controls designed to work as a system with Carrier's small packaged product. Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. High and Low Pressure Switches provide added reliability for the compressor. Indoor and Outdoor coils are computer -designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit. Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 73dBA. Easy to service cabinets provide easy 3 panel accessibility to serviceable components during maintenance and installation. The base with integrated drain pan provides easy ground level installation with mounting pad. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4 -in. wide perimeter flange makes frame mounting on a rooftop easy. Convertible duct configuration Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow with the two standard duct covers. Downflow operation is easily provided in the field to allow vertical ductwork connections. The basepan utilizes seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Cabinets are constructed of heavyduty, phosphated, zinc -coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator and electric heater compartments are insulated with cleanable semi-rigid insulation hoard, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air 1 Conditioning Engineers No. 62P.) The sloped drain pan minimizes standing water in the drain. An external drain is provided. Short -Cycling protection for the compressor is incorporated into our defrost control board ensuring a five minute delay (+/-2 minutes) before restarting compressor after shutdown for any reason. TABLE OF CONTENTS FEATURES/BENEFITS 1 MODEL NUMBER NOMENCLATURE 2 AHRI CAPACITIES 3 PHYSICAL DATA 4 OPTIONS AND ACCESSORIES 5 ROOF CURB ACCESSORY DIMENSIONS 6 BASE UNIT DIMENSIONS 7-8 SELECTION PROCEDURE 10 PERFORMANCE DATA 11-24 TYPICAL PIPING AND WIRING 25 APPLICATION DATA 26 ELECTRICAL DATA '78 TYPICAL WIRING SCHEMATICS 30-35 CONTROLS 36 GUIDE SPECIFICATIONS 37-38 MODEL NUMBER NOMENCLATURE 50VT C 24 Type of Unit 50VT - Single Packaged Heal Pump System N/A Major Series Nominal Cooling Capacity 24 - 2.0 Tons 30 - 2.5 Tons 36 - 3.0 Tons 42 - 3.5 Tons 48 - 4.0 Tons 60 - 5.0 Tons N/A c LISTED US 3 1 Options LT - 2% air leakage, tin plated indoor coil hairpins and louver metal outdoor grille. TP - Base unit with tin plated indoor coil hairpins (Single Phase ;Only) See Price Page for full list of factory options. Only used 4 ordering an option Minor Series Electrical Supply 3 - 208/230-1 - 60 5 - 208/230-3-60 6 - 460- 3- 60 .4i CERTIFIO ti'k. Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program For verification of certification for individual products, go to www.ahridireclory.org. ASIMAE COMPLIANT. z O Lu z 0 ce o U a o z z Q a a EXISTING CURB LAYOUT Hea 0O 20 zo (0 en PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0182 DATE: 11/30/17 " PROJECT NAME: TARGET AGENT GRID SITE ADDRESS: 17640 WEST VALLEY HWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ars tw& YOi Building Division Public Works n Fire Prevention Structural Planning Division n ❑ Permit Coordinator Tr]I PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 12/05/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/02/18 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 COMFORT MECHANICAL INC Washington State Department of Labor & Industries Hoine Lsspano1 Contact. Safety & Health Claims & Insurance Page 1 of 2 Search L&I A -Z Hrdex I-lelp Workplace Rights Trades & Licensing COMFORT MECHANICAL INC Owner or tradesperson Principals JACKSON, SHIRLEY A, PRESIDENT JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA 98002 425-251-9840 KING County Business type Corporation Governing persons HERB J JACKSON SHIRLEY A JACKSON; License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOMI015LA Effective — expiration 06/01/1999— 04/25/2018 Bond Lexon Ins Co Bond account no. 9815017 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 06/04/2012 06/01/2012 Expiration date Until Canceled Bond history Insurance AMCO Ins Co Policy no. AC P3008276478 Received by L&I 05/24/2017 Insurance history Savings $1,000,000.00 Effective date 06/01/2017 Expiration date 06/01/2018 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 12/8/2017 PARCEL Parcel Number 252304-9017 Name TERRENO 17600 WVH LLC Site Address 17600 WEST VALLEY HWY 98188 ILegal S329.85 FT OF GL 7 LY BET PST & P R/W & CO RD LESS ST HVVY PROJECT DESCRIPTION: 1. REPLACE (1) 2.5 -TON ROOF MOUNTED PACKAGED HEAT PUMP WITH NEW 2.5 -TON ROOF MOUNTED PACKAGED HEAT PUMP WITH ECONOMIZER. GENERAL NOTES: 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING AND MULTIPLE COOLING STAGES. 2. NO MODIFICATIONS TO EXISTING STRUCTURE PER STRUCTURAL CALCS. 3 ANCHORAGE: (3) #10 SMS PER SIDE. 4. THERMOSTAT TO PROVIDE MINIMUM 50 DEADBAND. 5.7 -DAY PROGRAMMABLE THERMOSTAT WITH LOCKOUT. 6. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 7. ROUTE CONDENSATE TO SPLASH BLOCK ON ROOF. 8. PROVIDE COMMISSIONING REPORT. HVAC Equipment Schedule (New) # Brand Model Ton 1 Total CFM Cap. Heat Cap. Cool SEER Weight Sound(bels) Location RTU -1 Carrier 50VT-C30 2.5 1 963 28,000 28,000 14 351 75 Roof Project Briefly the text ill This provisions MECH-SUM, Energy Description describe mechanical systems In box provided Total Bldg Performance (TBP) path includes all mandatory per C401.2 Option 2. MECH-CHK and 0407 Analysis forms required. n ,__,New Building DBuiithng Addition DTenant Improvement REPLACE (1) 2.5 -TON ROOF MOUNTED PACKAGED HEAT PUMP El System Retrofit WITH NEW LIKE UNIT. No System Changes Design Load Calculations 1 Load calculation summary Provide design load calculations for all ventilating needs. If a load calculation summary compliance information then the MECH-LOAD-CALC • mechanical MECH-LOAD-CALC Form systems and equipment serving the building heating, cooling or is provided with the permit documents that includes all applicable form is not required. Mechanical Schedules Fi Mechanical Plans Indicate location of equipment compliance however, include on plans all applicable 1 compliance MECH-EQ Forms (TBD) information. If provided on plans then MECH-EQ forms am not required, information listed in MECH-EQ tables. Dedicated Outdoor .Air System Requirements arid High Efficiency VAV Alternate • All not • 1 DOAS occupied, require • • ill DOAS DOAS 1 Is required per C403.6 effective July 1, 2017 (office, retail, education, library and fire station occupandes) conditioned areas shall be served by a DOAS that delivers required ventilation air In a manner that does space conditioning fan operation. Space conditioning fans cycled off when no heating or cooling Is required Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, Exception 1) Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS (C403.6, Exception 2) included in project, although not required (occupancy not office, retail education, library or fire station) related allowances Included in project: Prescriptive vertical fenestration maximum area allowance increased to 40% per 0402.4.1.4 with 100% of conditioned floor area In building served by DOAS. Exception to air economizer per C403.3 Exception 1, Include MECH7ECONO form. Fan Power El is Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. For one or more systems, the total fan motor nameplate hp of all fans In HVAC system exceeds 5hp. /f yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section c403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Ilydronic Systems 1 1 Hydronic chilled water HydronIc heating water 0 1 Water -loop heat pump Geothermal .., No hydronic systems C406 Additional Efficiency Options - Mechanical • 1 1 0406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than minimum requirements. All stand alone supply, retum, and exhaust fans over 1hp must have FEQ 71 and must be selected within 10% of maximum total or static pressure. 0406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. C406.7 Reduced energy In service water heating Requires 90% of tloor area be in occupancy types listed in C406.7.1 and that 60% of annual hot water energy use be provided by heat pump, waste heat recovery or solar water -heating systems. Note 1- Constant Volume (CV), Variable Air Volume (VAV), or HospitaULab CV system that qualifies for VAV budget per C403.2.11.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list al! fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. Include all supply, retum/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3- Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes), or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No) MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan RECEI System Form) to generate an additional form Added forms can be deleted with button in cell E32 of the added form. CITY OF T RiU-1 30'1 I I TRANSPORT AGENT GRID 1. ROOF PLAN - NO SCALE REVISIONS No changes shall ho made to the Scope of work without prior approval of Tukwila Boilding Division - NOTE: RevLsons Will require a new plan submittal and may ins:ude additional plan review fees 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 -,- mu - Mechanical Summary MECH-SUM Date 11/7/2017 2015 Washington State Energy Code Compliance Forms for Commercial Buildin. s includin. R2 & R3 over 3 stories and all R1 Revised January 2017 Project Information Project Title: Transport Agent Grid Date 11/7/2017 System Total Nameplate HP (Note 3) Applicant Information. Provide contact information for Individual who can respond to inquiries about compliance form Information provided. For Building Dept. Use CV Company Name: COMFORT MECHANICAL. 0.5 No Company Address: 3202 C ST NE AUBURN, WA 98002 Applicant Name JESSE CHUTICH Applicant Phone: 425-251-9840 Project Briefly the text ill This provisions MECH-SUM, Energy Description describe mechanical systems In box provided Total Bldg Performance (TBP) path includes all mandatory per C401.2 Option 2. MECH-CHK and 0407 Analysis forms required. n ,__,New Building DBuiithng Addition DTenant Improvement REPLACE (1) 2.5 -TON ROOF MOUNTED PACKAGED HEAT PUMP El System Retrofit WITH NEW LIKE UNIT. No System Changes Design Load Calculations 1 Load calculation summary Provide design load calculations for all ventilating needs. If a load calculation summary compliance information then the MECH-LOAD-CALC • mechanical MECH-LOAD-CALC Form systems and equipment serving the building heating, cooling or is provided with the permit documents that includes all applicable form is not required. Mechanical Schedules Fi Mechanical Plans Indicate location of equipment compliance however, include on plans all applicable 1 compliance MECH-EQ Forms (TBD) information. If provided on plans then MECH-EQ forms am not required, information listed in MECH-EQ tables. Dedicated Outdoor .Air System Requirements arid High Efficiency VAV Alternate • All not • 1 DOAS occupied, require • • ill DOAS DOAS 1 Is required per C403.6 effective July 1, 2017 (office, retail, education, library and fire station occupandes) conditioned areas shall be served by a DOAS that delivers required ventilation air In a manner that does space conditioning fan operation. Space conditioning fans cycled off when no heating or cooling Is required Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, Exception 1) Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu of DOAS (C403.6, Exception 2) included in project, although not required (occupancy not office, retail education, library or fire station) related allowances Included in project: Prescriptive vertical fenestration maximum area allowance increased to 40% per 0402.4.1.4 with 100% of conditioned floor area In building served by DOAS. Exception to air economizer per C403.3 Exception 1, Include MECH7ECONO form. Fan Power El is Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. For one or more systems, the total fan motor nameplate hp of all fans In HVAC system exceeds 5hp. /f yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section c403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Ilydronic Systems 1 1 Hydronic chilled water HydronIc heating water 0 1 Water -loop heat pump Geothermal .., No hydronic systems C406 Additional Efficiency Options - Mechanical • 1 1 0406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than minimum requirements. All stand alone supply, retum, and exhaust fans over 1hp must have FEQ 71 and must be selected within 10% of maximum total or static pressure. 0406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. C406.7 Reduced energy In service water heating Requires 90% of tloor area be in occupancy types listed in C406.7.1 and that 60% of annual hot water energy use be provided by heat pump, waste heat recovery or solar water -heating systems. CO PM ermit No, \1117. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted coda or ordnance. Receipt of approved Field Copy and cond' s is acknowledged: By: Date: 12-A fX-z City of Tukwila BUILDING DIVISION 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stones and all R1 Mechanical Fan System Power Allowance MECH-FANSYS-SUM 015 Washjnaton State Enerav Code Com !lance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January2ol7 — ' Project Title: Transport Agent Grid Date 11/7/2017 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. System or Primary Supply Fan ID Speed Control (Note 1) Description (Note 2) System Total Nameplate HP (Note 3) Fan Power Calculation Required (Note 4) RTU -1 CV HEAT PUMP 0.5 No Note 1- Constant Volume (CV), Variable Air Volume (VAV), or HospitaULab CV system that qualifies for VAV budget per C403.2.11.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Describe system type and list al! fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. Include all supply, retum/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan -powered terminals. VAV parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3- Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Note 4 - This form automatically identifies whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance (Yes), or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less (No) MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan RECEI System Form) to generate an additional form Added forms can be deleted with button in cell E32 of the added form. CITY OF T REVISIONS z. 0 DATE : SCALE DRAWN: CHECKED: I SPPi RE( RATE PERMIT .UIRED FOR: Mechanical Electrical Plumbing Gs Piping y of Tukwila DivisioN VED KWILA NOV 30 2017 - PERMIT CENTER