Permit M17-0184 - INNOVASIAN CUISINE - HOOD AND INLINE EXHAUST FAN
INNOVASIAN CUISINE 116 ANDOVER PARK E M17-0184 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT 0223000060 Permit Number: M17-0184 116 ANDOVER PARK E INNOVASIAN CUISINE Issue Date: 1/12/2018 Permit Expires On: 7/11/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: PIETROMONACO/PB L L C 7900 SE 28TH ST STE #310 , MERCER ISLAND, WA, 98040 DAN MCNEELY 8300 RAILROAD AVE SE #1775 , SNOQUALMIE, WA, 98065 SKILFAB SHEET METAL CO 8300 RAILROAD AVE SE #1775 , SNOQUALMIE, WA, 98065 SKILFSM169RE Phone: (425) 831-5555 Phone: (425) 831-5555 Expiration Date: 1/22/2019 DESCRIPTION OF WORK: INSTALLATION OF AN 8 FT TYPE I HOOD WITH AN INLINE EXHAUST FAN. NO ROOFTOP WORK Valuation of Work: $30,400.00 Type of Work: NEW Fuel type: GAS Fees Collected: $610.58 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature Print Nam Date: 02-11P) This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 3: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 4: Local U.L. central station supervision is required. (City Ordinance #2437) 5: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 6: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 7: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.12.5) 8: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 15: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 16: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 17: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 18: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 19: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 20: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 21: ***MECHANICAL PERMIT CONDITIONS*** 22: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 23: Manufacturers installation instructions shall be available on the job site at the time of inspection. 24: Type 1 Hoods, the required grease duct leakage test and light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL 0710 TYPE 1 HOOD AND DUCT CITY OF TUKWILA Community Development Department Permit Center 6300 SouthcenterBlvd., Suite 100 Tukwila, WA 98.188 http://www.TulcwilaWA.gov Mechanical Permit No. ( '7 -0(0-11 Project No. Date Application Accepted: Date Application Expires: II -30-17 s-30-18 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION �1 // � w-- // King Co Assessor's Tax No.: C2)93O00040 Site Address: 116 U44clol,4/t pW� c Suite Number: Floor: New Tenant: ❑ Yes ..No Tenant Name: PROPERTY OWNER Company Name: SL/Li / / 6 / _/_ , Address: g,30,it,4j Git,,tG 56 -- City: nState: (s Zip:104,s_ Phone: Fax: y2S-83J-sSSr 4/2S-P3)-ss7,g- Namel/L e P dOG. Address: U City: �-fz /,a State: / ,/ Zip: clew CONTACT PERSON — person receiving all project communication • Name: Addres 300 Azt City: Phone: Email: Sify -93 '12-5- 9 3/ s3-5--Ye9jte. MECHANICAL CONTRACTOR INFORMATION Company Name: SL/Li / / 6 / _/_ , Address: g,30,it,4j Git,,tG 56 -- City: nState: (s Zip:104,s_ Phone: Fax: y2S-83J-sSSr 4/2S-P3)-ss7,g- Contr Reg No.: `k 1 Lys M I r b"t i�f= n .Exp Date: ` y 7 izo 1 9 Tukwila Business License No.: Valuation of project (contractor's bid price): $ O. 9k 11'' Describe the scope of work in detail: ( 8 �G lefrt Use: Fuel Type: Residential: New ❑ Replacement 0 Commercial: New ,.j Replacement ❑ Electric ❑ Gas ❑ Other: /i///g H:\Applications\Foto-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh T e Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system I Air handling unit 65 dB(A) <10,000 cfin 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct I Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Day Telephone: CO 5. 831 - Ss -Ss - Mailing Address: 4+1 9 H:\Applications\Forms-Applications On Line12016 Applications\Mechanical Permit Application Revised 1-4-I6.docx Revised: January 2016 bh City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $69.87 M17-0184 Address: 116 ANDOVER PARK E Apn: 0223000060 $69.87 Credit Card Fee $2.04 Credit Card Fee R000.369.908.00.00 0.00 $2.04 MECHANICAL $67.83 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R13619 R000.345.830.00.00 1.00 $67.83 $69.87 Date Paid: Tuesday, January 30, 2018 Paid By: DANIEL MCNEELY Pay Method: CREDIT CARD 01196E Printed: Tuesday, January 30, 2018 12:40 PM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $610.58 M17-0184 Address: 116 ANDOVER PARK E Apn: 0223000060 $610.58 MECHANICAL $587.10 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $436.53 PLAN CHECK FEE R000.322.102.00.00 0.00 $117.42 TECHNOLOGY FEE $23.48 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12904 R000.322.900.04.00 0.00 $23.48 $610.58 Date Paid: Thursday, November 30, 2017 Paid By: SKILFAB SHEET METAL CO Pay Method: CHECK 8205 Printed: Thursday, November 30, 2017 11:44 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M )7-09y vc)/ Projec VG, -S Type of Inspection: G.AiQc atL 6:01}AL Address: il 74.77t. r Date Called: Special Instructions: Date Wanted: ® _& ' a.m. p.m. Requester: Phone No: 174 Approved per applicable codes. Corrections required prior to approval. COMMENTS: FhttaL Inspector: Date: i,/`/C .20e REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M tii-o r� Project: A�0all l\a04> Type of Inspection: lpit vlIL�C11 RI -i Address: ,Ver6Ve'r ?)i-r1C--F. Date Called: penal Inst uctions: Date Wanted: a.m� ^ Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. OMMENTS: % Oleejlja ` ( Inspector j >p a/ Date: ��g .'2i REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Mil-o18�( Project: t ` . T �iitj Vc S AAS e cS/r, e Type of Inspection; h'k1 C.0.1. 1- ► JL Address:( _ ' j� 'tP 'T4)CtOjl ►-k F - e Date Called: Special Instructions: *61r L% ce_ l5 c lW 1 Date Wanted: q%Z"ZD/S a.m. P.m• Requester: 1I % CCI Phone No: 20 "79,3- 81q3 Approved per applicable codes. AlCorrections required prior to approval. COMMENTS: ( h' Co r11 -a. tinier -VI - a. pub (>30i -p ® . y,v,a vice �-a f CP41(.41 is A/6+ instil / Cj41,(5 Oeci/) ri2ov.cs)-P.k -GrzNeija /i4ed /O 44614.1 vi: , e)(4944er (31 Date: L' z_20123,, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit M1`l-a 8y PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Pro ect: % ' !sillC, Type of Inspection: Mr..616..eAct . � r'hrAt D "GSiA-1J Address:.Date Pt&d° frile147 Called: pate W�t 'yZoid Cemmp e Requesr Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: plar�t c�.l �inA-1. —' ►'�G�i+�t 11 ,eXit tkod ** l ir+++ur1 ',`ter►. np,4 is der be tC / 1L - eilut - w svt_ Pln;r„w- .5 Pr rfee1 . Inspector: nig? asst. Date:si//x , 'l REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedute reinspection. INSPECTION RECORD Retain a copy with permit Airi-olg1/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: /WO VR3'i COS/JV, a of Inspecuo �� 4 Ad�j cess: // moo 17 , to Caliedb tc Special instructions: 7/P 4DOCT• 1 HS Oi-ifeAtAii.m. Cfi_ A- c s Date Wanted: Requester: xnrvirt GL Phone No:t ws"-g.J Z i ?9Z Approved per applicable codes. COMMENTS: Corrections required prior to approval. 1. A.4.4.10 meet ntyv-fieriace- 6N sfic d[se cits< t t 04-1,47114 1S) Roryspevvillipy (Heerr4±sse/ Itlspector:C....(2......._ Date: REINSPECTION, FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cat[ to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. 1117-0/84-1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438.9350 Project: '01.40c11/eSie4(L1.1Sinc e of Inspection: (I.4_) .L c L Address: JV✓ 4eir-- /I( Date Ile r""\ SpecialInstructions: Date Wanted:_ 2 7 % (Sl .' mtimr Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENT - NTS. I 11 cvm`v )a 1-1-te_Celc Inspector: %� �.r REINSPECTION FEE REQUIRED. Prior to next inspec$'on. f must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit /Fi`? Q/21 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /NNai/ ohs/Ay/NE Type of Inspection: Address: #6 If/Y.0 0ER J Aqk E, Date Called: Special instructions: 'TyPe 1 tita f ' 1100 PSI Ott- Afi ANA BOK Date Wanted: P. --I -18 p.m: Requester: S—Trie Phone No: 2-53-85.'2" � Approved per applicable codes. COMMENTS: EJCorrections required prior to approval. 0.41. YPr fievap AUcT Lt6H-7— 7 57 Inspector: .05 Date: ; _ 9./8 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 I7 ofgy Project: MA/0VAS A/ Clivi NE Type of inspection: Address: //4, 44/Di(,4 FrIRK Date Called: Special Instructions: TY1 1ec�A 4''DUCT Date Wanted: .2-8-16 a. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: .13y ccorraNeoR Inspector: Date: 8 r-( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Btvd.. Suite 100. Calc to schedule reinspection. Job #1819 Innovasian Field Balance Report Service Region: Tukwila WA Service Person: Dan McNeely Customer Number: 18198 Customer Name: Steven Vern Address: Innovasian Cuisine Ent. 116 Andover Park East. Tukwila WA 98188 Region Job # 18198 Region Job Name: Innovasian Sales Region: Bargreen Ellingson Tacoma Sales Person: Jason Stratton Created By: Dan McNeely Creation Date: 4/2/2018 2:15pm Last Modified by: Dan McNeely Last Modified Date: 4/2/2018 3:30pm Dining Room Pressure: 0 Hours on Job: 0 Kitchen Pressure: 0 Extra Hours: 0 Completed: Yes Completed By: Dan McNeely Completion Date: 4/2/18 3:30pm Hood Group 1 Exhaust CFM: Design 2400 Actual 2369 98.70% of design Hood 1 Model: SkCan Slope 8' 0" Exhaust CFM design: 2400 Length: 8' 0" actual: 2369 98.70% of design #s$krVE /CIE Job #1819 Innovasian Field Balance Report Service Region: Tukwila WA Service Person: Dan McNeely Customer Number: 18198 Customer Name: Steven Vern Address: Innovasian Cuisine Ent. 116 Andover Park East. Tukwila WA 98188 Region Job # 18198 Region Job Name: Innovasian Sales Region: Bargreen Ellingson Tacoma Sales Person: Jason Stratton Created By: Dan McNeely Creation Date: 4/2/2018 2:15pm Last Modified by: Dan McNeely Last Modified Date: 4/2/2018 3:30pm Dining Room Pressure: 0 Hours on Job: 0 Kitchen Pressure: 0 Extra Hours: 0 Completed: Yes Completed By: Dan McNeely Completion Date: 4/2/18 3:30pm Hood Group 1 Exhaust CFM: Design 2400 Actual 2369 98.70% of design Hood 1 Model: SkCan Slope 8' 0" Exhaust CFM design: 2400 Length: 8' 0" actual: 2369 98.70% of design INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit III 17- 0/6Y / -F-0631 /?- —03`7) a PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Type /A'- /�r�, m -J of Inspection: o% Address:Contact Suite #: /j6 ,4p _ Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: y.*57 Sprinklers: Fire Alarm: Hrs.: Hood & Duct: Monitor:`{ Pre -Fire: Permits: Occupancy Type: / l/.4f fi-c_ / Ai oad `? 4/f - — '`'c -S / Needs Shift Inspection: y.*57 Sprinklers: Fire Alarm: Hrs.: Hood & Duct: Monitor:`{ Pre -Fire: Permits: Occupancy Type: Inspector-- -'G y.*57 Date: 9///%/ b Hrs.: /. U $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14, T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 18-J--0(03 rpt I 1 —01 PERMIT NUMBERS Project: /M OVk w --.s Type of Inspection: Iv0d Address:r Suite #: 11� -Q Special L Contact Person: Instructions: Monitor: Phone No.: Approved per applicable codes. iorrect1ons required prior to approval. COMMENTS: /`'o Z10/A/X77/,(fes- /t4,#ve-e,` 74. f -- Needs Shift Inspection: Sprinklers: Hrs.: /• 0 Fire Alarm: Hood & Duct: `_ Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: _ y2 Date:.//(/� j 8 Hrs.: /• 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 City of Tukwila Department of Community Development December 14, 2017 DAN MCNEELY 8300 RAILROAD AVE SE SNOQUALMIE, WA 98065 RE: Correction Letter # 1 MECHANICAL Permit Application Number M17-0184 INNOVASIAN CUISINE - 116 ANDOVER PARK E Dear DAN MCNEELY, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Provide a wall detail where the Type I hood shall be installed Specify type of framing materials consist of and backing of the Type I hood. 2. Plan indicates the duct to discharge horizontally through the exterior wall. Provide full details describing the existing wall construction and show clearance around the duct from combustible construction. One concern is how termination of the exhaust duct is constructed to prevent moisture intrusion and protecting the exterior of the building around the duct penetration from grease buildup. Construction details shall be consistent with the 2015 Mechanical Code. (IMC Section 506.3.11, 506.3.13.2, and 506.3.13.3) 3. The plan shows a cross cut reference key A-ID1. I could not find that detail. Please clarify or remove that key marker. 4. Provide note on the plan: Type I hoods and ducts shall be inspected by approved inspection agencies that satisfy the requirements as to qualifications and reliability. Final inspection reports from such approved agencies of the Type I hood and duct shall be accepted by the code official after the special inspections of hood and duct have been completed. (2015 IMC SECTION 107 & IMC 506.3.2.5) 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Note: Contingent onresponse to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. M17-0184 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0184 DATE: 01/16/18 PROJECT NAME: INNOVASIAN CUISINE SITE ADDRESS: 116 ANDOVER PARK E Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Iff Building Division Public Works El AM fhP l -18-t8 Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 01/18/18 Structural Review Required DATE: 111 APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 02/15/18 Notation: REVIEWER'S INITIALS: DATE: ;Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0184 PROJECT NAME: INNOVASIAN CUISINE SITE ADDRESS: 116 ANDOVER PARK E Original Plan Submittal X Response to Correction Letter # 1 DATE: 01/08/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: �gKw° 11\1(6 uiIding Divisi n Fire Prevention Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/09/18 Structural Review Required REVIEWERS INITIALS: DATE: ❑ APPROVALS OR CORRECTIONS: DUE DATE: 02/06/18 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERC INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg]] Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0184 PROJECT NAME: INNOVASIAN CUISINE SITE ADDRESS: 116 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # DATE: 11/30/17 Revision # 1 before Permit Issued Revision # after Permit Issued DEPARTMENTS: ceitt Building Division Public Works ❑ (7 Apt /wc i)-�«--( 7 Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 12/05/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 01/02/18 ❑ Approved with Conditions ❑ Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: ) 1i r -( Bldg [�Fire 0 Ping 0 PW 0 Staff Initials: U1 12/18/2013 EXHAUST TO HAVE FIRE -WRAP 2 -HOUR 0" CLEARANCE TO COMBUSTIBLES. MOTORIZED DAMPER TIED TO HOOD —18.0000— 96.0000 /BOTTOM OF FLOOR JOIST -18.0000-- 39.- 566 0000 11 111111.1101 0 —_$ L — .2768 ROP CEILING STAINLESS WALL FLASHING SCALE: 1/2"=1' HOOD ELEVATIONS FAN UNIT Na TAG FAN UNIT MODEL # CFM ESP. RPM HP. B.H.P. 0 VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS.) SEINES 1 EF NCA14FA 2400 1.000 1329 1.500 0.7750 3 208 4.6 759 FPM 144 17.6 FAN UNIT NO. TAG OPTION (City. - Descr.) 1 EF 1 - Grease Box 1 - Extra Set of Belts 1 - Fan Base Ceramic Seal - Installed At Plant - For Grease Ducts 1 - Hinge Kit - Ships Loose for Curb Supplied by Others FAN UNIT NO. TAG EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 EF YES FAN 1#1 NCA14FA - EXHAUST FAN (EF) DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) FEATURES: - ROOF MQDNTED FANS - RESTAURANT MODEL - 1L705 AND UL762 - ANCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - VEATHERPF* DISCONNECT - HIGH FEAT OPERATION300F 049'C) - GREASE CLASSIFICATION TESTING 108801. TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 3001E (149'0) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM. AND WIIQDIT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY VH/LE EXHAUSTING BURNING GREASE VAPORS AT 600'r (316'C) 008 A PERIOD 13 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TEL ANY EXTENT THAT COU.D CAUSE AN UNSAFE 0000rTDIN. OPTIONS GREASE BOX EXTRA SET OF BELTS FAN BASE CERAMIC SEAL - INSTALLED AT PLANT - FOR GREASE DUCTS HINGE KIT - SHIPS LOOSE FOR CURB SUPPLIED BY OTHERS JOB Innovasian - EF LOCATION SNOQUALMIE, WA, DATE 1/3/2018 JOB # 3257131 DWG # 1 DRAWN BY RTB - 85 REV. SCALE' 3/8' = 1'-0' 20.0 000 24. 000 WALL CONSTRUCTION CONCRETE ROOM 116 EXHAUST BIRD SCREEN COVER AIR INTAKE LOUVER 24"X24" ROLL DOWN PROJECTION SCREEN CONFRANCE ROOM 121 STORAGE 117 L r P2=:,1 COO 8 4 a 4 e. 4 Q • -L. r ti -22 GAUGE STAINLESS STEEL GYPSUM WALL BOARD N-20 GAUGE STEEL STUDS EINFORCED CONCRETE ALL CONCRETE, FRAMING, G.W.B. BY OTHERS Cr i�'77:7 ie lT �a I--Oi : -.; .`�chanical Es/Electrical Q/Plumbing was Piping °.amity of Tukwila BUlLOING DIVISION WALL SECTION AT HOOD FXLE COP Permit I:. M C8 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinanc R Receipt of approved Field C, and co d` io -r o `> :d: By: 150/17.1116"°g/ ` 1,,,`,1;(� Date:/�a/ r�' City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope pf work without prior approval of Tukwila Building Division. VOTE: i ;cvisions will require a new plan submittal and may include additional plan review fees. j RE VISION J\:OL Ml7 01811 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 f : 2018 LK City of Tukwila RECEIVED CITY OF TUKWILA JAN 16 2018 PERMIT CENTER 1 m m 0 0 a) E LL F- () w O-7 a 0 N E LL w 0 U) 08/20/2015 w SCALE Varies 45 0 0 E LL Lu J 1- 1= 1-- w w 9 0) office@skilfab.com PO BOX #1775/ Snoqualmie Washington 98065/ (street) 8300 Railroad AVE SE / Phone: 425.831.5555/ Fax: 425.831.5575 /T REVISION WINDOWS DO NOT OPEN WALK IN FEEEZER EXHAUST AND FAN EXHAUST IS DIRECTED AWAY FROM BUILDING AND OPENINGS INTAKE 2'X2' LOUVER WAREHOUSE DESK 'WAREHOUSE DESK WAREHOUSE DESK SERVER ROOM WEARHOUSE ELEVATOR 110 FOYER 111 1 WEARHOUSE NORTH ELEVATION @ DUCT TERMINATIONS EMPLOYEE BREAK ROOM 2ND STAIR 112 HALL ELETRICAL ROOM 1/4X2 HAMMER SET CONCRETE ANCHOR ELETRICAL ROOM STORAGE RESTROOM FIRE WRAP BARRIER SPRINKLER RISER KITCST HEN RESTROOM INFILL BETWEEN WALL AND POST TO CREATED FULL HEIGHT WALL FOR NEW SIGNAGE. RECEPTION ROLL DOWN e• PROJECTION SCREEN 16 GAUGE DUCT CAP FAN TO BE HINGED ON THIS CAP WHICH IS WELDED TO THE DUCT tormswaskaviog CONFRANCE ROOM REVIEWED FOR CODE COMPLIANCE APPROVED • JAN 2 4 2010 STEEL FLASHING City of Tukwila BUILDINGDLV1SION OMPOSITE PLAN MAIN STAIRS Date: 8-10-17 NORTH Scale: NOTED Drawn by: sg/mjl Job: InnovAsian Tukwila, WA COMPOSITE PLAN 1ST FLOOR SCALE: 1/8" = 1'-0" Site Plan NOT TO SCALE SITE INFO: Site address: 116 Andover Park E Tukwila, WA 98188 Parcel: 0223000060 Contact: Joseph Zalke 18251 B Cascade Ave S Tukwila, WA 98188 (425)251-3706 x2702 Kitchen Mechanical Contractor: Skilfab Industries 8300 Railroad ave SE Snoqualmie, WA 98065 (425)831-5555 Codes; System to be installed and commissioned per: 2015 IMC NPFA 96 2015 WSEC 2015 IBC KEF-x: Kitchen Exhaust Fan MUA-x: Make-up Air Fan Fire suppression by others Electrical by others Plumbing by others Notes: SEPARATE: PERMIT i EQUP..wD FOR: ElfMechanical Lt Electrical ErPlumbing tai Gas Piping City of Tukwila BUILDING DIVISION No changes s'i�,tl ,,_, nip ,, ;o the scone of work without prix( of Tukwila Building C?ivisior�. NOTE: Revisions will require a new plan submittal and may include additional plan review tees , Y Permit iso.FILE Mfl CO- \`6 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Data: IIt°)‘�l�City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 10 2018 P -J 1212- City of Tukwila BUILDIN .DIVISION RECEIVED CITY OF TUKWILA JAN 482018 PERMIT CENTER CoRBE ION LTR# I m O 0 0 E LL 1- 0 W O a. 45 0 E it CUSTOMER 08/20/2015 SCALE Varies 0 E Jr: SHEET TITLE it r1 LJ EXHAUST FAN & MAKE UP AIR UNIT VERIFY LOCATION a I I I � I .I II .I % I II 11 II I I 1I 11 I I I CIOK INE 1-- 1 A i‘ 1 I / \\ \ I \ I I / •I •• 1 PRELIMINARY NOT FOR CONSTRUCTION r5 PREP NIMMMN 1 MOOMMII MIMEO MMIM I —PULL STATION 1 I ■���Yars-� SCULLERY 1111 111 III III IIII III EQ.,IPN E\ T PLA\ Scale: 1/4"=1'-0" CD d - N co 0 L(j c? r --- co co LO C.4 LO N LC) N N V c X O J0 LLL RELEASE INFORMATION DATE 07/21/17 This plan is the property of Bargreen Ellingson and is loaned subject to the condition that it is not to be copied, reproduced, or distributed either in whole or in part, without written permission, and is not to be used in any way detrimental to the best interests of the company. ©2014 BARGREEN ELLINGSON INC. DRAWN BY: B. FLANNERY PROJECT MANAGER: J. STRATTON SHEET TITLE: FOODSERVICE EQUIPMENT PLAN SHEET NUMBER 1 OF 6 PROJECT NUMBER 3893 REVIEWED F -OR CODE COMPLIANCE APPROVED JAN 10 2011 City of Tukwila BUILDING JRVICION RECEIVED CITY OF TUKWILA JAN 0 8 2018 PERMIT CENTER organ ThermalCeramics Insulating Our World Datasheet Code US: 7-14-236 MSDS Code US: 406 © 2009 Morgan Thermal Ceramics, a business within the Morgan Ceramics Division of The Morgan Crucible Company plc ICC • Commonly referred to test method CA Section 01350 is CDPH Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers Version 1.1, Feb 2010 Grease Duct Enclosure System Air Ventilation Duct Enclosure System Product Data & Installation Guide 1. Product Description FireMaster® FastWrap XL is a flexible blanket composed of high temperature fibers classified for applications to 2192°F (1200°C) and fully encapsulated in a durable glass fiber reinforced foil facing for easy handling and installation. FastWrap XL is UL and ULC Listed for 1 and 2 hour fire resistive enclosure protection, zero clearance for kitchen exhaust ducts, electrical circuit protection, and as a component in UL firestop designs for fire resistance rated floors, ceilings, and walls. The core fibers in FastWrap XL are manufactured using Morgan Thermal Ceramics patented Superwoole' fiber which is an alkaline -earth silicate wool with low biopersistence and therefore increased safety for installers. FastWrap XL is under UL's Follow -Up Service Program to ensure the consistent quality essential to this life -safety application. Morgan ThermalCeramics Product Features • Thin and Lightweight at 1-1/2" (38mm) thick, 6 pcf (96 kg/m3) density • Contours easily to complex duct designs • Grease duct installation UL and ULC Listed with butt joints at all seams on both layers • Fully foil encapsulated for fast and clean installation • Contains 2192°F (1200°C) rated fibers • Microbial Resistance validated by UL Environment • Good sound absorption • Compliant to IMC, NFPA 96, UMC, CMC, CNBC 2. Applications • 1, 2 and 3 hour enclosure and firestop systems for kitchen exhaust ducts • Zero clearance to combustibles for kitchen exhaust ducts • 1 and 2 hour enclosure and firestop system for hazardous exhaust ducts, pressurization ducts, clothes dryer exhaust ducts, trash and linen chutes, and other fire rated HVAC ducts • 1 hour electrical circuit integrity protection • Engineered and tested solutions for fire protection of structural steel and storage vessels per ASTM E119, ISO 834, and UL1709 3. Specifications - Division 23 07 00 (or 15080) CSI Spec and AutoCAD available online, www.arcat.com/sd/clients/thermcer.html. FireMaster FastWrap XL is a flexible high temperature insulation rated to 2192°F (1200°C) that is fully encapsulated in FSP facing. The duct enclosure system shall be listed by UL and /or ULC per ASTM E 2336, CAN/ULC S144 and ISO 6944 for 1-, 2- and 3 -hour rating and zero clearance to com- bustibles, and tested per ASTM E84 for a flame/smoke rating Tess than 25/50. Insulation shall have a nominal thickness of 1-1/2 inches (38 mm) and density of 6 lbs/ft3 (96 kg/m3). Insulation shall have a R -Value of 7.3 at 75°F. Installation shall be in strict accordance to manufacturers published installation instructions, UL or ULC Listings, and shop drawings. FireMaster FastDoorT'" XL shall be used for duct access where specified or as required by code. www.morganthermalceramics.com 1 Grease and HVAC Duct Enclosure System 1 or 2 Hour Shaft Alternative / Zero Clearance to Combustibles lir Pail I ,Orn Butt Joint / Butt Joint Typical TWO LAYER INSTALLATION (Grease Duct Der ASTM E2336 and CAN/ULC S144) 0 117(3{) 1, • •• 11.1m. kNatanvaaaxwa3 21't5301•p. Telescope Wrap Option Butt Joint Option 141_1_2.Sat I 21.(533) TW. I \ Checkerboard Wrap Option SINGLE LAYER INSTALLATION OPTIONS (2 -Hour rated HVAC Duct oer UL HNLJ V-19) LEGEND 1 Two Layers of XL Insulation for ASTM E2336 and CAN/ULC S144 Grease Duct Enclosur One Layer of XL Insulation for 2 -Hour Air Ventilation Duct Enclosures 2 Steel banding minimum 1/2" (13) wide by 0.015" (0.4) thick. 3 Tight butt joints (no overlap) at perimeter and longitudinal joints, both layers for grease dt 4 Min. 3" (75) overlap on perimeter and between adjacent blankets 5 Optional 6" XL collar 6 Hangers - size dependent weight of assembly (see datasheet Section G) 7 Trapeze Supports - size dependent on weight of assembly (see datasheet Section G) 8 Steel Rectangular or Round Duct (size, gage and construction dependent per Listed Des s cls gn) www.morganthermalceramics.com Morgan ThermalCeramics 4. Physical Characteristics Insulating Our World Product Unit Size Units/ Ctn. Wt./ Ctn. FastWrap XL Roll 1-112" x 24" x 25' 1 37.5 lbs. FastWrap XL Roll 1-1/2" x 48" x 25' 1 75 lbs. 5. Performance Specifications Reference Standard Standard No. Performance Grease Duct Enclosure System ASTM E2336 Pass Section 16.1 - Non -Combustibility ASTM E136 Pass Section 16.2 -Fire Resistance (wall) ASTM E119 Pass - Test Section 16.3Durability ASTM C518 Pass Section 16.4 - Internal Fire• Test ASTM E2336 Pass Section 16.5 - Fire Engulfment (duct) ASTM E814/E119 Pass ULC Grease Duct Test Protocol ULC Pass Standard Methods of Fire Resistance Tests - Grease Duct Assemblies CAN/ULC 5144 Pass Grease Duct Clearances UL 1978 Pass Air Ventilation Duct Enclosure ISO 6944 Pass Surface Burning Characteristics ASTM E84 <25/50 Thermal Resistance (R -value @ 75°F) ASTM C518 7.3 per layer Mold Growth ASTM C1338 ULE Validated Low VOCs CA Standard 01350 ULE Validated U Morgan ThermalCeramics 6. Listings/Building Code Reports Listed Uses Agency Listing Layers Grease Duct Enclosure per ASTM E2336 and AC101 (2006, 2009, 2012 IMC, NFPA 96, UMC, CMC) UL G18 2 ICC -ES ESR 2213 ULC Grease Duct Test Protocol and CAN/ULC S144° ULC FRD 4, 7' 2 Grease Duct Insulation (2003 IMC) OPL TC/BI 120-01 1 Through Penetration FireStop System per ASTM E814, UL 1479 UL See Figure 2 1 or 2 ULC 1- or 2 -hour Ventilation Duct Enclosure per ISO 6944-1985 UL HNLJ.V1, 19, 29 1 ULC FRD 3, 5, 6, 18 3 -hour Ventilation Duct Enclosure per ISO 6944-1985 UL HNLJ-V2 2 Electrical Circuit Protective System UL FHIT.5 2 7. Storage FastWrap XL must be stored in a dry warehouse environment on pallets. Pallets should not be stacked. 8. Installation FastWrap XL shall be installed by a qualified contractor in accordance with manufacturer's instructions and laboratory design listings. Materials and Equipment • FastWrap XL blanket • Aluminum foil tape • Glass filament reinforced tape (optional) • Carbon steel or stainless steel banding material, minimum 112" (13mm) wide, minimum 0.015" (0.4mm) thick, with steel banding clips • Hand banding tensioner and crimping tool • Minimum 12 gage (3mm) steel insulation pins; steel speed clips, minimum 1-1/2" (38mm) square or 1-1/2" (38mm) diameter, or equivalent sized cup -head pins; • Capacitor discharge stud gun • Morgan Thermal Ceramics FastDoorTm XL • An approved firestop sealant www.morganthermalceramics.com Insulating Our World Commercial Kitchen Grease Duct Enclosure System Air Ventilation Duct Enclosure System Through Penetration Firestop Systems IXL Insulation continuous through rated wall assembly XL insulation temtlnated on both sides of the rated wall assembly 01:2013 Page 2 of 8 IXL Insulation continuous through rated floodceiling assembly XL insulation terminated at the top and bottom surface of the floor/ceiling assembly Firestop Designs per ASTM E814 / UL 1479 - Consult UL / ULC Directories for System Details UL Listing F- & T -Rating (1) Floor/Wall (2) Penetrant (3) Enclosure Per (4) Termination (5) Firestop Sealant Details C -AJ -7012 2 -hour Concrete/CMU 84x24; 26 Ga Duct V19; FRD3; 5; 18 wrap through 1/2 in; STI; Tremco C -AJ -7014 3 -hour Concrete/CMU 84x24; 26 Ga Duct V2: wrap through 1/2 in; STI; Tremco C -AJ -7019 1 or 2 -hour Concrete/CMU 84x24; 26 Ga Duct V19; FRD3, 5, 18 lerminate at 114 in; STI; Tremco GAJ -7021 2 -hour Concrete/CMU 49x24; 16 Ga Duct G18; FRD4; 7 terminate at 1/4 in; STI; Tremco C -AJ -7095 2 -hour Concrete/CMU 39x39; 22 Ga Duct V19; FRD3, 5, 18 wrap through 1/4 in; 511 Hilti; Rectorseal; Tremco C -AJ -7098 2 -hour Concrete/CMU 49x24; 16 Ga Duct 618; FRD4; 7 wrap through 1/4 in; STI; Hilti; Rectorseal; Tremco F -C-7036 1 ort -hour Wood/Gyp Floor 24x12; 16 Ga Duct G18: FRD4; 7 wrap through 1/4 in; STI; Hilti; Rectorseal; Tremco F -C-7055 1 -hour Wood/Gyp Floor 4 Dia: 30 Ga Duct V29; FRD28 wrap through 1/4 in; STI W -J-7086 2 -hour Concrete/CMU Watl 1000100; 26 Ga Duct V19; FRD3;5; 18 terminate at 1/4 in; STI W -L-7121 1 or 2 -hour Gyp Wall 30x30; 16 Ga Duct 018; FRD4; 7 wrap through 1/4 in; STI; Hilti; Rectorseal; Tremco W -L-7145 1 or 2 -hour Gyp Wall 100x100; 26 Ga Duct V19; FRD3; 5; 18 terminate at 5/8 in; STI Tito int gdty of Morgan 'Memel Commies duct systems Is limited to the quatty a tho instaiialen. xwal-5 www.morganthermalceramics.com organ !Ceramics Insulating Our World General Cut edges of the blanket shall be taped with aluminum foil tape to prevent exposed edges of the insulation absorbing grease and moisture in the event of a compromised grease duct joint or condensation. Overlaps and/or tightly butted joints are used to block heat transfer in the event of duct deformation resulting from thermal expansion. Filament tape is suggested to hold the blanket in place until steel banding or pinning is installed to permanently secure the blanket. A. Installation on Grease Duct per ASTM E2336 and CAN/ULC S144 (Figure 1) System requires two layers of insulation applied directly to the duct with tight butt joints at all seams on both layers. The first layer of insulation is cut to a length sufficient to wrap around the duct and provide a tight butt joint where the blanket ends meet. Adjacent blankets on the first layer are butted tightly together with longitudinal seams offset minimum 6" (150mm). The second layer of insulation is installed in the same method as the first layer, with seams between layers offset a minimum of 6" (150mm). Banding and/or pinning per Section D is used to permanently secure the insulation to the duct. B. Installation on HVAC Duct per ISO 6944 (Figure 1) System requires one layer of insulation applied directly to the duct with 3" (75mm) overlaps at all seams. The insulation is cut to a length sufficient to wrap around the duct and provide a 3" (75mm) overlap where the blanket ends meet. Adjacent blankets are installed to provide a minimum overlap of 3" (75mm). Banding and/or pinning per Section D is used to permanently secure the insulation to the duct. C. 2 & 3 Sided Wrap Installation (Figure 4) When space does not allow for a complete wrap applied to the duct on all four sides, the FastWrap XL is approved for 2 or 3 sided installations with mechanical attachment to a rated concrete or CMU assembly. (See Figure 4 for installation details.) D. Mechanical Attachment Methods 1) Banding (Figure 1) - Minimum 1/2" (13mm) wide carbon steel or stainless steel banding, 0.015" (0.4mm) thick, is placed around the entire perimeter of the insulated duct on maximum 10-1/2" (270mm) centers and 1-1/2" (38mm) from each blanket edge or 1-1/2" (38mm) from each collar edge when using the butt joint and collar method. The banding is placed around the blanket and tightened to firmly hold the FastWrap XL in place against the duct, but not cause any cutting or damage to the blanket. 2) Pinning - Pinning on all sides of the duct may be used as an alternative to banding. For ducts wider than 24" (610mm) pinning is required on the bottom of horizontal runs, or on one side of vertical runs (in addition to steel banding). When applicable, 12 Gage (0.4mm) steel pins are installed on 12" (305mm) centers along the width of the duct and 10-1/2" (270mm) centers along the length of the duct. Pins that extend beyond the outer blanket layer shall be turned down or the excessive length cut off to prevent sharp edges. Shoot through pins (cup head pins) may be used in conjunction with steel banding to prevent blanket sag. E. Access Doors 1) FastDoorTM XL (Figure 3) - FastDoor XL is a UL Listed, liquid tight duct cover panel supplied complete with a single layer insulation cover per UL Listing HNKT G18. The FastDoor XL is installed per included installation instructions. No field welding is required. 2) Field Fabricated Access Doors - Each access door assembly has four threaded rods 1/4 inch (6mm) in diameter and 5" (127mm) in length, with one welded to each corner of the door opening. Hollow steel tubes, 4-1/2" (114mm) long are installed outside the access cover plate and over the threaded rods. Four 12 gage (3mm) and 4-1/2" (114mm) long steel insulation pins are welded to the access cover plate to allow for installation of the three layers of FastWrap XL. One layer of FastWrap XL is cut to approximately the same size as the access panel, and impaled over the insulation pins on the panel. A second layer of FastWrap XL is cut so as to overlap the first layer a minimum of 1-1/2" (38mm). It is essential that the first and second layer fit tightly against the surrounding wrap with no through openings. The third and outside layer should be cut to overlap the second insulation layer by a minimum of 1-1/2" (38mm). Minimum 1-1/2" (38mm) round or square insulation clips are installed on the insulation pins to secure the three layers of insulation to the access cover plate. All cut edges of the insulation shall be taped with minimum 3" (75mm) wide aluminum foil tape. Wing nuts and washers are installed on the four threaded rods, and tightened against the hollow steel tubes to seal the www.morganthermalceramics.com Insulating Our World 01:2013 Page 3 of 8 FASTDOOR XL Access Door Systems ASTM E 2336 Compliant Enclosure and Door System FIGURE 3 1 UL listed FastDoor XL access panel 2 All Thread Rods and wing nuts 3 Retainer Clips with threaded nut and wing bolts 4 Insulation layers as required by UL or ITS Listings 5 FastDoor XL; 1-1/2 inch thick single layer insulation FastDoor XL1 Access Doors Sizes Available Opening Sizes Ordering Code 10" x 6" Door Opening 434-6970-034-99X1 12" x 8" Door Opening 434-6970-035-99X1 12" x 12" Door Opening 434-6970-036-99X1 16" x 12" Door Opening 434-6970-037-99X1 20" x 20" Door Opening 434-6970-038-99X1 www.morganthermalceramics.com Morgan ThermalCeramics Insulating Our World access cover plate to the duct. F. Through Penetration Firestop System (Figure 2) - When the duct penetrates a fire rated assembly an approved fire stop system must be employed. Figure 2 provides a complete list of UL 1 ULC firestop design listings which can be found in the Certifications Directory at www.ul.com for US systems and www.ulc.ca for Canadian systems. Prior to installing any firestop system the surfaces of all openings and penetrating items must be clean and dry. The FastWrap XL core blanket (or mineral wool where allowed by the firestop design listing) must be compressed into the annular space. The packing material must be recessed a minimum depth from the surface of the concrete or gypsum assembly. The recessed opening must be filled with a minimum thickness of an approved firestop sealant. The packing material type and compression, minimum recess (typically 1/4" (6mm)), and approved firestop sealant and thickness (typically 1/4" (6mm)) shall be as specified in an approved UL / ULC firestop design listing. When there is not sufficient annular space around the duct to run the FastWrap XL enclosure system continuous through the fire rated assembly, the enclosure may terminate above and below the floor/ceiling assembly or on either side of a wall assembly as shown in Figure 2. When this method is used, the FastWrap XL must be mechanically attached on either side of the fire rated assembly using one of the attachment methods described in Section D, spaced a maximum of 1-1/2" (38mm) from the fire rated assembly. G. Support Hanger Systems 1) Grease ducts: Trapeze support hangers shall be spaced on maximum 60 in. (1500 mm) centers. Hanger rods or straps shall be anchored with steel drop in or wedge expansion type masonry anchors. No additional protection is required for hangers and supports meeting the requirements of the Table below. Hanger Cross Section Maximum Perimeter, in (mm) Trapeze Support (or equiva- lent Yield Strength), in (mm) 36 in (10 mm) threaded rod 148(3759) 2 (51) x 2 (51) x 18 (3) in angle 2) HVAC ducts: Trapeze support hangers shall be spaced on maximum 60 in. (1500 mm) centers. Hanger rods or straps shall be anchored with steel drop in or wedge expansion type masonry anchors. No additional protection is required for hangers and Li Morgan ThermalCeramics supports meeting the requirements of the Table below. Hanger Cross Section Max. Perimeter, in (mm) Trapeze Support (or equivalent Yield Strength), in (mm) 1 in x 16 gage strap (25 mm x 1.5 gage strap) 100 (2540) 3 114dIn (6 mm) threaded 50 (1270) a1.74 n (38) x 1% (38) x 316 (5) 9 38 in (10 mm) threaded rod 150 (3810) 1% (38) x 1X (38) x 316 (5) angle 12 in (12.7 mm) threaded rod 218 (5540) 2 (51) x 2 (51) x 14 (6) angle 9. Maintenance and Repair No maintenance is required when installed in accordance with Morgan Thermal Ceramics (MTC) installation instructions. If damage is limited to the foil facing, aluminum foil tape can be used to repair the foil facing. If an area of blanket is found to be damaged the following procedure must be incorporated. If the damaged area is larger than 8" (203mm) x 8" (203mm) the entire wrap section must be removed and replaced according to MTC installation instructions. If the damaged area is small (less than 8" (203mm) x 8" (203mm)), the damaged area must be cut away and replaced with a new section 1" (25mm) larger in length and width than the cut out, such that the new section can be compressed tightly into the cut out area. All cut edges of the new section must be taped and sealed with aluminum foil tape. The new section must be held in place with either pinning or banding per MTC installation instructions. 10. Limitations Morgan Thermal Ceramics FireMaster FastWrap XL shall be installed in accordance with these installation instructions and appropriate laboratory design listings. The integrity of FastWrap XL systems is limited to the quality of the installation. *For personal protective equipment recommendations, please see SDS. Thermal Ceramics, FireMaster, and FastWrap are trademarks of Morgan Crucible Company Plc. FireMaster products are manufactured by Morgan Thermal Ceramics and are distributed by authorized distributors. www.morganthermalceramics.com Insulating Our World 01:2013 Page 4 of 8 Commercial Kitchen Grease Duct Enclosure System Air Ventilation Duct Enclosure System 1 Or 2 Hour Shaft Alternative / Zero Clearance to Combustibles 2 and 3 Sided Wrap Detail for Attaching to Walls and/or Cilings XL005-3 N. N. N. N. ..1 41 t 6 - 16 \ \ Note: Ducts must be independently supported per code O N. N. N. N. LEGEND 1 1 or 2 Hour Rated Concrete floor, ceiling, or wall 2 Two layers of XL Insulation for Grease Duct Enclosures (ASTM E2336) One layer of XL Insulation for Air Ventilation Duct Enclosures 3 Concrete fastener system 4 3/16" (5) thick x 2" (50) -3" (75) wide bar stock perforated 12" (305) o.c. 5 8" (203) maximum Air Gap 6 Duct 7 Steel banding min. 112" (13) wide by 0.015" (0.4) thick. 8 Banding clip The tetegdty of Morgan Thermal Ceramics duct systems s limited to the quality of the installatiat. the f,alc-.4�� ics.com • • • 0 �._- REVIEWED FOR CODE. COMPLIANCE APPROVED 10 7018 City of Tali wila RECEIVED CITY OF TUKWILA JAN 082018 PERMIT CENTER >- m 0 -3 1- 0 w 0 CUSTOMER 08/20/2015 SCALE Varies SHEET TITLE 01:2013 Page 5of8 01:2013 Page 6of8 01:2013 Page 7 of 8 9 1/2" Wood 11Sammy1l Bolt 8013925 GTS2 1/411 x 2" 1760 Lbs. Ultimate pullout Ceiling stud Composite Beam Connection Composite truss Allthread w/ fender washer and nut - Filler block extends 18" either direction of bolt location 1/2" Nut r 1/2"Lock Washer " -----1/2" Fender Washer Reinforced Composite Beam Connection 1/2" Lock Washer 1/2" Nut 1/2" Althread 1/2" Fender Washer 1/2" Lock Washer 1/2" Nut 1/2" Althread r 1/2" Nut 1/2r1Lock Washer Detail "A" Hood Connection I load Bracket 1/2" Lock Washer 1/2" Nut nistrut P1000T Unistrut Trapeze Lower pring Nut Steel Plate 1/2" Althread 1/2" Nut H Allthread 1/2" Fender Unistrut P1000 T 1/2"Lock Washer 1/2" Lock Washer Couple Nut Unistrut Trapeze Upper dame! Seledlor Chart i'.,Nat£0 tiharnel lions /1ddM100al 5500611100l6on9 1 q5; 41 14.1. ,5.' 41-� ' 10 frl 10 ?h23g )- 915 r 1V1` --I -- 1 II 2 11 I30 C14,M ..-G.. .. _ FOISP 'Le11;01 M§i151: P1010 P1000 7pP 0P '0 201 i0 0 201 40 11010 11010 00 OR 20 11900 10 18900 P1010 P1010 Pg, PG (0 1(9.00 20 119.00 P1010 P1010 00 20 20,41 211.40 11016 11000 20 119.00 101 19.01 P1010 81010 0L IL 20 119.00 10 100.02 011110 P1000 14. 211 10 7130 10 71 P10(0 PI0 23 95 10 19x1 20 1E6 Of P1000 0 67 20 11901 110110 07 10 119.01 1 q5; 41 14.1. ,5.' 41-� ' 10 frl 10 ?h23g )- 915 r 1V1` --I -- 1 II 2 11 I30 C14,M ..-G.. .. _ Weld 540,000.555 n' t9.6oh71 Ain t -I P.n 2-2 film'''" 10876.11 01656 17.711'1 02360' 19.80411 „,„,:t11 0202 I1 133 liTd1 0.240 in,128031 Rax I te' N Gy GSrn,19 ml 0051101'.7.1 Lnktuei Heght flat PA0ua0p ' L. a: SlatFaa 11191 MA C014mALOAD P008e ate.E. 6=065 1}031 N=160 2509 ('(8 0(111 K:t2 15x:1 24 36 3510 3.150 10.740 8.910 98110 7740 8,700 6310 7.740 5.310 46 80 2770 2310 7260 5 910 60,0 1690 1.650 .1.6'00 3100 2,960 2 11 2010 1.110 4140 1480 3800 2200 2560 2.110 2400 1.980 96 - 1.670 1580 110 1660• 1 0 100 1,9'u 1.1{0 ".150 2100 2110 4481 2110 1 1.611 • 111 1.1.74 260 1.660 ran �4 a4 L puZ 5 .m"S A: ,:m 1 , Y ,i ar 101 690, AI 101t (/ldt40ln Lasa (104' 018.1 U 0t T'L0 0170 tit., tlnlntn pled (101 Snap 880 066) Opan 72640 11811 an !3150. tk61 tlro0300: R90utt. 1.3[11 24 1690 006 9690 1690 1690 100 2b 4P 1.131 150 0.1" 071 1.1"U 050 113U 7211 500 inn 014 088 60 6F0 0.35 650 180 320 012 72 64 560 90 0.50 0.66 1"0 330 340 250 420 160 0.70 075 9E 00 +20 500 0.81 1.14 >50 :00 150 150 130 ,00 0.71 0.05 120 144 '210 710 1.10 2.110 160 110 120 80 80 60 066 061 168 192 :40 '10 22.72 3.55 80 60 60 50 1. 055 051 216 240 330 00 0.58 5.62 50 40 40 • 047 044 Area of Section 0.555('2 (3.661'2) Axis 1-1 Axis 2-2 Moment of Inertia (1) 0.185 int (7.7 cm') 0.236104 (9,8 cm4 r Section. Modulus (S1 0.202 in3 (3.3 cm3l 0.290 in-' (4.8 cm31 Radius of Gyration (r1 0.577 in(1.5 cm) 0.651 in(1.7cm) 4;11 bit Column L'rlad Unbraced Load at Applied at C.C. Height Slot Face:, K=0.65 K=0,80 K=1.0 K=1:2 (in) (Ibs) (lbs) (lbs) (lbs.) (lbs 24 3,550 10,740 9, 0 6,770 7,740 36 3.190 8.910 7.740 6,390 5,310 48 2,770 7.260 6.018 4.690 3,800 60 2,380 5,910 4,690 3,630 2.960 72 2.080 4,840 3,800 2.960 2.400 84 1.660 4.040 3,200 2,480 1,98a 96 1.670 3.480 2,750 2.110 1,660 108 1.510 3.050 2.400 1,810 120 1,380 2.700 2,110 144 1,150 2,180 1,660 'KUr > 200 Span (in) 24 36 48 60 72 84 96 108 120 1,690 1,130 850 689 560 480 420 380 340 0.06 0.13 0:22 0.35 0.50 0.68 0.89 1.14 1.40 Span /180 (lbs) 1,690 1,130 850 650 450 330 250 200 160 Span /240 (lbs) 1,690 1,130 760 480 340 250 190 150 120 Span /360 (lbs); 1,690 900 500 320 220 160 130 100 80 ateral Bracing `Redact: Factor 1.00 0.94 0.88 0.82 0.78 0.75 0.71 0.69 0.66 144 280 2.00 110 80 60 0.61 168 240 2.72 80 60 40 0.55 192 210 3.55 60 50 0.51 216 190 4.58 50 40 0.47 240 170 5.62 40 0.44 HOOD LENGTH: 8'-O" HOOD DUTY: MEDIUM CFM : 8*300=2400cfm Add 3-1/4" Angle along length of hood W / #12 Zinc SMS into studs. Detail "A" Hood #12 Stainless SMS into every stud. HOOD CONSTRUCTION: 16 GAUGE GALVANIZED STEEL, 18 GUAGE STAINLESS S1EEL.._ CvoK �o yo APPROVED FILTERS TO BE U.L. LISTED LIGHT FIXTURES TO BE U.L. 2015 IMC NPFA 96 LISTED°2018 L City of Tukwila BUIL I O: MISION RECEIVED CITY OF TUKWILA JAN 0 8 2018 PERMIT CENTER >- m m 0 0 E LL 0 W O cc 0 45 0 E LL CUSTOMER 08/20/2015 SCALE Varies 0 E LE SHEET TITLE 8 :2 8 0 r- 60 M 1.0 64) X co 64 ) Nit ID 0 a W co a co Goco N co rn s a- 0 iq Ln O m a EXHAUST TO HAVE FIRE -WRAP 2 -HOUR 0" CLEARANCE TO COMBUSTIBLES. /-BOTTOM OF FLOOR JOIST MOTORIZED DAMPER TIED TO HOOD u /GREENHECK Building Value in Air. 18.0000--- 96.0000 .0000 39.5566 JL ®® VT - L � t 18.0000--- .2768 ROP CEILING STAINLESS WALL FLASHING SCALE: 1/2"=1' HOOD ELEVATIONS Printed Date: 11/28/2017 Job: Skill Slab - Innov-Asian Mark: Mark 1 Model: TCB -2-12-20 Performance Quantity 1 Volume (CFM) 2,400 External SP (in. wg) 0.625 Total SP (in. wg) 0.625 Operating Power (hp) 1.48 Start -Up Power (hp) 1.48 Fan RPM 2604 Elevation (ft) 30 Start-up Temp.(F) 70 Operating Temp.(F) 70 Fan Configuration Size 12 Level 2 Discharge Position Horizontal Mounting Ceiling Hung Material Type Steel Equipment Weights Fan (LMD)(Ib) 130 Motor/Drive (Ib) 39 Accessories (Ib) 39 Misc Fan Data FEG 53 Outlet Velocity (ft/min) 1,304 Static Efficiency (%) 17 Tip Speed (ft/min) 8,352 Motor and Drives Motor Included Size (hp) 2 RPM 1725 Enclosure ODP Voltage 460 Cycle 60 Phase 3 Frame Size 56 Max Frame Size 182 Location C Pulley Type Constant Drive Loss (%) 5.3 Drives Single Drive Service Factor 1.5 NEC FLA* (Amps) 3.4 amca iORUMIDE OERTN1ED RRTIRGJ Model: TCB -2-12-20 Inline Centrifugal Fan Operating Performance 4.0 3.5 3.0 -63 2.5 2.0 1.5 0 c`n1.0 0.5 0.0 0 0 - 2604 FRAM >/ ro vsqi Q0 0 1_ ---------------- 1.6 1.4 1.2 1.0 Q. 0.8 3 -- 0.6 Y co 0.4 0 3 6 9 12 15 18 21 Volume (CFM) x 100 Operating Bhp point Operating point at Total External SP Operating point at External SP Fan curve - - System curve Brake horsepower curve Sound Power by Octave Band 0.2 0.0 24 27 Sound Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Inlet 84 81 84 83 80 77 81 71 87 75 •F - based on tables 150 or 148 of National E ectncal ode 2002. Actual motor FLA may vary, for siz ng thermal overload, consult factory. LwA - A weighted sound power level, based on ANSI S1.4 dSA - A weighted sound pressure level, based on 11.5 dB attenuation per octave band at 5 ft-dBA levels are not licensed by AMCA International LA C Generated by: daniel@dorse.com CAPS 4.24.1923 \\coho\Public\Daniel T\Winjobs\Skill Slab - Innov-Asian.gfcj Page 1 of 7 20.0000 L .7854 Type I Hood Special Inspections Type I hoods and ducts shall be inspected by approved inspection agencies that satisfy the requirements as to qualifications and reliability. Final inspection reports from such approved agencies of the Type I hood and duct shall be accepted by the code official after the special inspections of hood and duct have been completed. (2015 IMC SECTION 107 & IMC 506.3.2.5) GREENHECK CAPS 4.24.1923 Building Value in Air. 24.0 000 Printed Date: 1/28/2017 Jo •w• Skill Slab - nov-Asian ark: Mark 1 TCB -2-12-20 Model: TCB -2-12-20 Inline Centrifugal Fan Standard Construction Features: HOUSING: Continuously welded steel or aluminum housing {-) Inlet and outlet flanges with mounting holes {-} Aluminum rub ring {-} Meets AMCA type B spark resistance {-} Structural steel parts are phosphatized and coated with Permatector BEARINGS, SHAFT, AND WHEEL: Heavy duty, self -aligning ball or roller pillow block bearings with extended lubrication lines (-) Polished, solid steel shafts {-} Backward inclined aluminum wheel Selected Options & Accessories: Motor with Class F or Greater Insulation Coating - Permatector, Concrete Gray -RAL 7023, Fan and Attached Accesso Hanging, Isolator -Spring, Hanging, 1 Inch UL -762 - "Power Ventilators for Restaurant Exhaust Appliances" Extended Lube Lines - Copper Motor Cover - Steel Easy Access Door Grease Trap with Drain Connection, shipped loose Mounting Rails Drain Connection - 1" Pipe Thread w/Plug Unit Warranty: 1 Yr (Standard) IMC 2015 508.1 Makeup air Makeup air shall be supplied during the operation of commercial kitchen exhaust systems that are provided for commercial cooking appliances. The amount of makeup air supplied to the building from all sources shall be approximately equal to the amount of exhaust air for all exhaust systems for the building. The makeup air shall not reduce the effectiveness of the exhaust system. Makeup air shall be provided by gravity or mechanical means or both. Mechanical makeup air systems shall be automatically controlled to start and operate simultaneously with the exhaust system. \coho is\Da rated by: da Win' WALL CONSTRUCTION CONCRETE ROOM 116 EXHAUST BIRD SCREEN COVER GREENHECK Building Value in Air. AIR INTAKE LOUVER 24"X24" ROLL DOWN P BOJ ECTI O \, SCREEN CONFRANCE ROOM 121 i STORAGE 117 IDP1. 0 J Printed Date: 11/28/2017 Job: Skill Slab - Innov-Asian Mark: Mark 1 Model: TCB -2-12-20 Model: TCB -2-12-20 2015 IMC 507.1.1 Operation The exhaust fan serving the Type I hood S'Iall have automatic controls that will activate the fan when cooking the appliance that requires such Type I Hood is turned on, or a means of interlock shall be provided that will prevent operation of such appliances when the exhaust fan is not turned on. Where one or more temperature or radiant energy sensors are used to activate a Type I hood exhaust fan, the fan shall activate not more than 15 minutes after the first appliance served by that hood has been turned on. A method of interlock between an exhaust hocd system and appliances equipped with standing pilot burners shall not cause the pilot burners to be extinguished. A method of interlock between an exhaust hood system and cooking appliances shall not involve or depend upon any component of a fire -extinguishing system. Skill Slab - Innov-Asian.gfcj Page 2 of 7 .44 DIA. D VI 23.00 18.38 Inline Centrifugal Fan RI 18.38 21 63 P� SIDE VIEW UNTING HOLES SHOWS FROM INLET END OF UNIT NOT FIELD ROTATABLE 1" NPT Drain Connection CAPS 4.24.1923 26.00 END VIEW Notes: All dimensions shown are in units of in. Generated by: daniel@dorse.com \\coho\Public\Daniel T\Winjobs\Skill Slab - Innov-Asian.gfcj 21.75 MAX Bolt Circle 0 19.75 Flange Hole 0 0A4 Quantity 16 Page 3 of 7 GREENHECK Building Value in Air. Printed Date: 11/28/2017 Job: Skill Slab - Innov-Asian Mark: Mark 1 Model: TCB -2-12-20 23 0) to 1 TCB -2-12-20 Performance Min/Max Fan Curve Requested Volume (CFM) Actual Volume (CFM) Extemal SP (in. wg) Total SP (in. wg) Fan RPM Operating Power (hp) 2,400 2,400 0.625 0.625 2604 1.48 3274 FRpm 2879 <ZP- 114 2604 --bhp 807 REVIE CODEC( AFT JAN I" L -1-.10-1-1-1- ._.I_., ..1.._i._._i .. T. i t 1 1 5 10 15 20 25 Volume (CFM) x 100 Operating Bhp point O Operating point at Total External SP o Operating point at External SP Construction Limit Motor/System Limit Fan curve Min FRPM - - System curve Brake horsepower curve CAPS 4.24.1923 Generated by: \\coho\Public\Daniel TtWinj 3.0 2.5. 2.0 1.5 0 a) PER )MPLI I ICE lOVED 9'9019 1 i '�ifil� C`f �L"�Nlld 36 -E2 -122:72P 4 135°') VISION RECEIVED CITY OF TUKWILA JAN 0 8 2018 PERMIT CENTER >- co m 0 0 E U w 0 0_ 0 0 E LL CUSTOMER 08/20/2015 SCALE Varies 0 to E LL SHEET TITLE 8 3c 8 to co N : 425.831.5555/ F 0 0 t 0 t) 8300 Railroad AVE SE Q:',0 BOX #17751 Snoqualmi SERVER ROOM 109 ELEVATOR 110 FOYER 111 STAIR 112 HALL 113 ELETRICAL ROOM 115 ELETRICAL ROOM 116 SPRINKLER RISER 119 TEST KITCHEN 120 0 WALK IN FEEEZER WAREHOUSE DESK 'WAREHOUSE DESK WAREHOUSE DESK 108 0 WEARHOUSE WEARHOUSE OFF,IC 11;4 OFFICE 11 STORAGE 117 0 ROLL DOWN PROJECTION SCREEN --` CONFRANCE ROOM 121 NORTH 0 106 EMPLOYEE BREAK ROOM IQ] 105 RESTROOM 104 RESTROOM 103 107 0 INFILL BETWEEN WALL AND POST TO CREATED FULL HEIGHT WALL FOR NEW SIGNAGE. 0 *UP MAIN STAIRS 101 RECEP110N 102 ENTRY 100 COMPOSITE PLAN 1ST FLOOR WINDOWS DO NOT OPEN EXHAUST 10 -0" INTAKE 2'X2' LOUVER NORTH ELEVATION @ DUCT TERMINATIONS SCALE: 1/8" = 1'-0" REVIEWED FOR CCDE COMPLIANCE APPROVED JAN 10 it 0 City of Tukwila BUIL PING olyi I_ & I RECEIVED CITY OF TUKWIL izz=2 JAN 08 2018 vs) PERMIT CENTER REVISION DATE INIT t-6 00 00 00 w O 0 -] z 1 1 rl r-1 z w z 0 w -- w 0 O_ z COMPOSITE PLAN Date: 8-10-17 Scale: NOTED Drawn by: sg/mjI Job: InnovAsian Tukwila, WA ID1