Loading...
HomeMy WebLinkAboutPermit M17-0189 - CATALYST WORKPLACE - GRDS AND THERMOSTATSCATALYST WORKPLACE 10848 E MARGINAL WAY S M17-0189 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0323049164 10848 E MARGINAL WAY S Project Name: CATALYST WORKPLACE Permit Number: M17-0189 Issue Date: 12/11/2017 Permit Expires On: 6/9/2018 Owner: Name: Address: E MARGINAL WAY PROPS LLC 3006 NORTHUP WAY STE 101, BELLEVUE, WA, 98004 Contact Person: Name: TAYLOR LOWERY Address: Contractor: Name: Address: License No: Lender: Name: Address: 1221 SECOND AVE N , KENT, WA, 98032 HERMANSON COMPANY LLP 1221 2ND AVE N , KENT, WA, 98032- 2945 HERMACL005B1 Phone: (206) 817-9099 Phone: (206) 575-9700 Expiration Date: 8/25/2018 DESCRIPTION OF WORK: 23 GRD'S, 5 THERMOSTATS RELOCATION, REUSING MOST EXISTING GRD'S Valuation of Work: $30,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $615.18 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform .Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: ,/ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Nam l7 oy 1 Date:I L/ 1 I f 11 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL 11) CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. j"( ( ` d ( y I Project No. Date Application Accepted: 19- ` H - 7 Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: U p 4 D f. Yutot,r King Co Assessor's Tax No.: 0 3 2_3 ( 46) 1124 rod WouJ S Suite Number: Floor: ((\� Tenant Name: Wl 1 All St W(} V 1G4 -e,; New Tenant: ❑ Yes Y.No PROPERTY OWNER Name: — I A LI/VO Y Lowe v`�- Name: cotkait1Si' W 1G1ct, City: V-Ln-fV" State: �,� I # Zip: (lc0r03Z V Address: In 4 . mourckinc4.4Wow S. City: -Ici , V , A , Im State: w Zip: GI It CONTACT PERSON — person receiving all project communication Name: — I A LI/VO Y Lowe v`�- Address: 1,Lt 2A l a fIQ City: V-Ln-fV" State: �,� I # Zip: (lc0r03Z V Phone: 4 511 �Kax. 25 Email: iv i mr. I UWCrw &, h?rmrxnSON MECHANICAL CONTRACTOR INFORMATION Company Name: `krrna, 1S0n, C b. Address:'Z.LI i nd 14V I M . City: p State: IAA Zip:01 60 iz Phone: Lou a,.1 ci oatgFax. Contr Reg No.: ft x, 00 5xo ate: to it.15/ i g Tukwila Business License No.: E kA S _ 0 olai 44 ti 4 o rvt Valuation of project (contractor's bid price): $ i )0 1 000 , d 0 Describe the scope of work in detail: Use: Fuel Type: Residential: Commercial: Electric 23 C IZVS 5 t SI-arl-S re) 0coLti a v \(-cu nT- m 06 t f).iSt r- C, QTY S New ❑ Replacement ❑ New ❑ Replacement Gas ❑ Other: H:\Applications\Forms-Applications On Line \2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 2.3 Floor furnace 5 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm 2.3 Evaporator cooler 5 Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 2.3 Thermostat 5 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-1OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDINGWNER 0 AUTHORIZED AGENT: Signature: • (\./t0\ Print Nam;:f6 0 y/ i 6ti,?JV' Mailing Address: 1 2.1 Znol kit) N • H:Wpplications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Date: Z/ Day Telephone: 2. % - Qc‘9A �fXl� W 1cr qlS U� City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK 1 ACCOUNT QUANTITY PAID $615.18 M17-0189 Address: 10848 E MARGINAL WAY S Apn: 0323049164 ' $615.18 Credit Card Fee $17.92 Credit Card Fee R000.369.908.00.00 0.00 $17.92 MECHANICAL $574.29 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $426.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $114.86 TECHNOLOGY FEE $22.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12937 R000.322.900.04.00 0.00 $22.97 $615.18 Date Paid: Monday, December 04, 2017 Paid By: SYDNEY LOWERY Pay Method: CREDIT CARD 256983 Printed: Monday, December 04, 2017 10:40 AM 1 of 1 ?SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ProjeccFcAl. We4RAtmedi Pe ofRiT Rat Fn. M�F Address: E. i Date Called: ‘oetiK pecial Instructions *e-Wated . 6.201 a. P.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ecko,niCAL — DJ A J`1 ed 1 CAL rimoL kr Inspect (NW Date:4/ /(o" 2.0 ?l REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Hermanson Project: Hermanson Company LLP 1221 2nd Avenue North Kent, WA 98032 tel 206-575-9700 fax 206-575-9800 Catalyst Workplace Activation 10848 E. Marginal Way S. Tukwila, WA 98168 Date: November - 30, 2017 Load Calculations REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 8 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 04 2017 PERMIT CENTER Mechanical Construction, Engineering and Service www.hermanson.com 3) Hermanson SPACE INPUT DATA System Loads Carrier HAP Version 5.1 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Roof Constructions 11/29/2017 01:53PM Existing Roof Roof Details Outside Surface Color Medium Absorptivity 0.675 Overall U -Value 0.030 BTU/(hr•ft2•°F) Roof Lavers Details (Inside to Outside Layers Thickness in Density Ib/ft' Specific Ht. BTU / (Ib•°F) R -Value (heft'•°F)/BTU Weight Ib/ft' Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 R-30 batt insulation 9.000 0.5 0.20 28.84615 0.4 22 gage steel deck 0.034 489.0 0.12 0.00011 1.4 4 -in LW concrete 4.000 40.0 0.20 3.33333 13.3 Built-up roofing 0.375 70.0 0.35 0.33245 2.2 Outside surface resistance 0.000 0.0 0.00 0.17000 0.0 Totals 13.409 - 33.36703 17.3 Hourly Analysis Program v5.10 Page 1 of 1 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Window Constructions 11/29/2017 01:54PM Existing Glazing 10' Window Details: Detailed Input Yes Height 10.00 ft Width 1.00 ft Frame Type Aluminum with thermal breaks Internal Shade Type None Overall U -Value 0.612 BTU/(hrft2•°F) Overall Shade Coefficient 0.545 Glass Details: Gap Type 1/2" Air Space Glazing Glass Type Transmissivity Reflectivity Absorptivity Outer Glazing 1/4" gray tint 0.479 0.062 0.459 Glazing #2 1/4" clear 0.792 0.079 0.129 Glazing #3 not used 1.000 0.000 0.000 Existing Glazing 3' Window Details: Detailed Input Yes Height 10.00 ft Width 1.00 ft Frame Type Aluminum with thermal breaks Internal Shade Type None Overall U -Value 0.612 BTU/(hrft2•°F) Overall Shade Coefficient 0.545 Glass Details: Gap Type 1/2" Air Space Glazing Glass Type Transmissivity Reflectivity Absorptivity Outer Glazing 1/4" gray tint 0.479 0.062 0.459 Glazing #2 1/4" clear 0.792 0.079 0.129 Glazing #3 not used 1.000 0.000 0.000 Hourly Analysis Program v5.10 Page 1 of 1 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Wall Constructions 11/29/2017 01:52PM Existing Wall Wall Details Outside Surface Color Medium Absorptivity 0.675 Overall U -Value 0.113 BTU/(hrft2•°F) Wall Lavers Details (Inside to Outside Layers Thickness in Density Ib/ft3 Specific Ht. BTU / (Ib•°F) R -Value (hrft2•°F)/BTU Weight , Ib/ft2 Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 Gypsum board 0.625 50.0 0.26 0.56000 2.6 R-11 batt (24" O.C.) 4.000 0.5 0.20 6.60000 0.2 8 -in HW concrete 8.000 140.0 0.20 0.66667 93.3 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 12.625 - 8.84467 96.1 Hourly Analysis Program v5.10 Page 1 of 1 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-01 E Conference 1. General Details: Floor Area 245.0 Avg. Ceiling Height 10.0 Building Weight 70.0 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults .. ASHRAE Standard 62.1-2010 ft2 ft Ib/ft2 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 500.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: 2.4. People: Occupancy 9.0 People Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. SE 333.0 0 0 0 3.1. Construction Types for Exposure SE Wall Type Existing Wall 4. Roofs, Skylights: Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 245.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.50 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 245.0 ft2 Total Floor U -Value 0.420 BTU/(hrft2•°F) Exposed Perimeter 20.8 ft Edge Insulation R -Value 10.00 (hrft2•°F)/BTU 7. Partitions: 7.1. 1st Partition Details: 7.2. 2nd Partition Details: Partition Type Wall Partition (No partition data). Area 193.0 ft2 U -Value 0.333 BTU/(hrft2•°F) Uncondit. Space Max Temp 82.0 °F Ambient at Space Max Temp 82.0 °F Uncondit. Space Min Temp 55.0 °F Ambient at Space Min Temp 24.0 °F Hourly Analysis Program v5.10 Page 1 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-02 SE Open Office 1. General Details: Floor Area 675.0 Avg. Ceiling Height 10.0 Building Weight 70.0 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults .. ASHRAE Standard 62.1-2010 ft2 ft Ib/ft2 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 1540.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: 2.4. People: Occupancy 14.0 People Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. SE 745.0 12 0 1 3.1. Construction Types for Exposure SE Wall Type Existing Wall 1st Window Type Existing Glazing 3' Door Type SEA -NR Swinging 4. Roofs, Skylights: Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 675.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.50 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 675.0 ft2 Total Floor U -Value 0.420 BTU/(hr•ft2-°F) Exposed Perimeter 43.0 ft Edge Insulation R -Value 10.00 (hr•ft2•°F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v5.10 Page 2 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-03 SW Open Office 1. General Details: Floor Area 715.0 Avg. Ceiling Height 10.0 Building Weight 70.0 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults .. ASHRAE Standard 62.1-2010 ft2 ft Ib/ft2 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 400.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: 2.4. People: Occupancy 16.0 People Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. SE 123.0 0 0 1 SW 1692.0 50 0 1 3.1. Construction Types for Exposure SE Wall Type Existing Wall Door Type SEA -NR Swinging 3.2. Construction Types for Exposure SW Wall Type Existing Wall 1st Window Type Existing Glazing 10' Door Type SEA -NR Swinging 4. Roofs, Skylights: Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 715.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.50 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 715.0 ft2 Total Floor U -Value 0.420 BTU/(hr•ft2•°F) Exposed Perimeter 129.0 ft Edge Insulation R -Value 10.00 (hr•ft2•°F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v5.10 Page 3 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-04 Conference 1. General Details: Floor Area 395.0 ft2 Avg. Ceiling Height 10.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults .. ASHRAE Standard 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 650.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: 2.4. People: Occupancy 14.0 People Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants - 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 395.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 395.0 ft2 Total Floor U -Value 0420 BTU/(hrft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 10.00 (hrft2•°F)/BTU 7. Partitions: 7.1. 1st Partition Details: 7.2. 2nd Partition Details: Partition Type Wall Partition (No partition data). Area 647.0 ft2 U -Value 0.330 BTU/(hrft2•°F) Uncondit. Space Max Temp 82.0 °F Ambient at Space Max Temp 82.0 °F Uncondit. Space Min Temp 55.0 °F Ambient at Space Min Temp 24.0 °F Hourly Analysis Program v5.10 Page 4 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-05 Open Office 1. General Details: Floor Area 1835.0 ft2 Avg. Ceiling Height 10.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults _ ASHRAE Standard 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented). Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 2860.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: 2.4. People: Occupancy 26.0 People Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 1835.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 1835.0 ft2 Total Floor U -Value 0.420 BTU/(hr•ft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 10.00 (hr•ft2•°F)/BTU 7. Partitions: 7.1. 1st Partition Details: Partition Type Wall Partition Area 1223.0 ft2 U -Value 0.330 BTU/(hr•ft2•°F) Uncondit. Space Max Temp 82.0 °F Ambient at Space Max Temp 82.0 °F Uncondit. Space Min Temp 55.0 °F Ambient at Space Min Temp 24.0 °F 7.2. 2nd Partition Details: (No partition data). Hourly Analysis Program v5.10 Page 5 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-06 Enclosed Office 1. General Details: Floor Area 90.0 ft2 Avg. Ceiling Height 10.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults .. ASHRAE Standard 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 135.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: 2.4. People: Occupancy 1.0 Person Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 90.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 90.0 ft2 Total Floor U -Value 0420 BTU/(hr•ft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 8.00 (hr•ft2•°F)/BTU 7. Partitions: 7.1. 1st Partition Details: Partition Type Wall Partition Area 163.0 ft2 U -Value 0.330 BTU/(hr•ft2•°F) Uncondit. Space Max Temp 82.0 °F Ambient at Space Max Temp 82.0 °F Uncondit. Space Min Temp 55.0 °F Ambient at Space Min Temp 24.0 °F 7.2. 2nd Partition Details: (No partition data). Hourly Analysis Program v5.10 Page 6 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-07 Meeting 1. General Details: Floor Area 115.0 ft2 Avg. Ceiling Height 10.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults.. ASHRAE Standard 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 300.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: 2.4. People: Occupancy 3.0 People Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 115.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 115.0 ft2 Total Floor U -Value 0.420 BTU/(hrft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 8.00 (hrft2•°F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v5.10 Page 7 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-08 Open Office 1. General Details: Floor Area 3450.0 ft2 Avg. Ceiling Height 10.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults .. ASHRAE Standard 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 2420.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: 2.4. People: Occupancy 30.0 People Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. SW 185.0 10 0 0 3.1. Construction Types for Exposure SW Wall Type Existing Wall 1st Window Type Existing Glazing 10' 4. Roofs, Skylights: Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 3450.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 3450.0 ft2 Total Floor U -Value 0420 BTU/(hrft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 8.00 (hrft2•°F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v5.10 Page 8 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-09 Conference 1. General Details: Floor Area 95.0 ft2 Avg. Ceiling Height 10.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults .. ASHRAE Standard 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 300.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: 2.4. People: Occupancy 4.0 People Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 95.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 95.0 ft2 Total Floor U -Value 0.420 BTU/(hr•ft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 8.00 (hr•ft2•°F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v5.10 Page 9 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-10 Telephone Room 1. General Details: Floor Area 35.0 ft2 Avg. Ceiling Height 10.0 ft Building Weight 70.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults .. ASHRAE Standard 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 50.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: 2.4. People: Occupancy 1.0 Person Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 35.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 35.0 ft2 Total Floor U -Value 0.420 BTU/(hr•ft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 8.00 (hr•ft2•°F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v5.10 Page 10 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-11 Telephone Room 1. General Details: Floor Area 35.0 ft2 Avg. Ceiling Height 10.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults ASHRAE Standard 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 50.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: 2.4. People: Occupancy 1.0 Person Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 35.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 35.0 ft2 Total Floor U -Value 0.420 BTU/(hr•ft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 8.00 (hr•ft2•°F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v5.10 Page 11 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-12 Conference 1. General Details: Floor Area 125.0 ft2 Avg. Ceiling Height 10.0 ft Building Weight 70.0 Ib/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults .. ASHRAE Standard 62.1-2010 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office Lights/Elec 2.2. Task Lighting: Wattage 0.00 W/ft2 Schedule None 2.3. Electrical Equipment: Wattage 300.0 Watts Schedule 90.1 Office Lights/Elec 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: 2.4. People: Occupancy 4.0 People Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule 90.1 Office Occupants 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 125.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 125.0 ft2 Total Floor U -Value 0.420 BTU/(hrft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value 8.00 (hrft2•°F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v5.10 Page 12 of 13 TUK_Catalyst Workplace Activation_v5_1 HERMANSON COMPANY LLP Space Input Data 11/30/2017 01:19PM 01-13 Copy/Mail Room 1. General Details: Floor Area 125.0 Avg. Ceiling Height 10.0 Building Weight 70.0 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 5.0 CFM/person OA Requirement 2 0.06 CFM/ft2 Space Usage Defaults .. ASHRAE Standard 62.1-2010 ft2 ft Ib/ft2 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 0.89 W/ft2 Ballast Multiplier 1.08 Schedule 90.1 Office LightslElec 2.2. Task Lighting: Wattage Schedule 0.00 W/ft2 None 2.3. Electrical Equipment: Wattage Schedule 90.1 Office LightslElec 500.0 Watts 3. Walls, Windows, Doors: (No Wall, Window, Door data). 4. Roofs, Skylights: 2.4. People: Occupancy 0.0 Person Activity Level Office Work Sensible 245.0 BTU/hr/person Latent 205.0 BTU/hr/person Schedule None 2.5. Miscellaneous Loads: Sensible 0 BTU/hr Schedule None Latent 0 BTU/hr Schedule None Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 125.0 0 0 4.1. Construction Types for Exposure H Roof Type Existing Roof 5. Infiltration: Design Cooling 0.00 CFM Design Heating 0.00 ACH Energy Analysis 0.00 CFM Infiltration occurs at all hours. 6. Floors: Type Slab Floor On Grade Floor Area 125.0 ft2 Total Floor U -Value 0.420 BTU/(hr•ft2•°F) Exposed Perimeter 0.0 ft Edge Insulation R -Value . 8.00 (hr•ft2•°F)/BTU 7. Partitions: (No partition data). Hourly Analysis Program v5.10 Page 13 of 13 Hermanson SYSTEM INPUT DATA System Loads Carrier HAP Version 5.1 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP RTU -R01 Input Data 11/30/2017 01:19PM 1. General Details: Air System Name RTU -R01 Equipment Type Packaged Rooftop Units Air System Type Single Zone CAV Number of zones 1 2. Ventilation System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Ventilation Sizing Method ASHRAE Std 62.1-2010 Unocc. Damper Position Closed Damper Leak Rate 5 % Outdoor Air CO2 Level 400 ppm Economizer Data: Control Integrated enthalpy control Upper Cutoff 75.0 °F Lower Cutoff 35.0 °F Central Cooling Data: Supply Air Temperature 55.0 °F Coil Bypass Factor 0.100 Cooling Source Air -Cooled DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 86.9 °F Heating Source Combustion - Natural Gas Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw-thru Fan Performance 1.75 Overall Efficiency 54 Fan Control 2 -speed fan cooling, 1 -speed fan heating Low Speed Fan Airflow 67 in wg ok Ok Duct System Data: Supply Duct Data: Duct Heat Gain 3 % Duct Leakage 2 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 1 Cooling T-Stat Occ. (°F) 01-05 Open Office x1 01-06 Enclosed Office x1 01-07 Meeting x1 Thermostats and Zone Data: Zone Cooling T-Stat Occ. (°F) Cooling T-Stat Unocc. (°F) Heating T-Stat Occ. (°F) Heating T-Stat Unocc. (°F) T-Stat Throttling Range (°F) Diversity Factor (%) Direct Exhaust Airflow (CFM) Direct Exhaust Fan (kW) 1 75.0 80.0 72.0 55.0 1.50 100 0.0 0.0 Thermostat Schedule 90.1 Office HVAC Unoccupied Cooling is Available Supply Terminals Data: Hourly Analysis Program 5.10 Page 1 of 10 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP RTU -R01 Input Data 11/30/2017 01:19PM Zone Terminal Type Air Distribution Air Distribution Effectiveness Specification Air Distribution Effectiveness Minimum Airflow Fan Performance Fan Efficiency Design Supply Temp. 1 Diffuser (no reheat) Ceiling supply / ceiling return ASHRAE 62.1 1 0.30 CFM/ft2 - - - Zone Heating Units: Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer -Generated): System Sizing Data: Sizing Data: Cooling Supply Temperature 55.0 °F Supply Fan Airflow 1327.5 CFM Ventilation Airflow 276.8 CFM Heating Supply Temperature 86.9 °F Hydronic Sizing Specifications: Chilled Water Delta -T 10.0 °F Hot Water Delta -T 20.0 °F Safety Factors: Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Sum of space airflow rates Space Airflow Sizing Method Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 1300.9 - - 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load 42.5 MBH Design OAT 95.0 °F Equipment Sizing User -Defined Gross Cooling Capacity 1.0 MBH Compressor & OD Fan Power 1.000 kW DX System Configuration 1 -stage compression, 1 circuit Conventional Cutoff OAT 55.0 °F Low Temperature Operation Not used Central Heating Unit - Combustion Estimated Maximum Load 23.3 MBH Equipment Sizing User -Defined Gross Heating Capacity 1.0 MBH Average Efficiency 85.0 % Misc. Electric 0.000 kW Hourly Analysis Program 5.10 Page 2 of 10 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP RTU -R02 Input Data 11/30/2017 01:19PM 1. General Details: Air System Name RTU -R02 Equipment Type Air System Type Number of zones Packaged Rooftop Units Single Zone CAV 1 2. Ventilation System Components: Ventilation Air Data: Airflow Control Ventilation Sizing Method Unocc. Damper Position Damper Leak Rate 5 % Outdoor Air CO2 Level 400 ppm Constant Ventilation Airflow ASHRAE Std 62.1-2010 Closed Economizer Data: Control Integrated enthalpy control Upper Cutoff 75.0 °F Lower Cutoff 35.0 °F Central Cooling Data: Supply Air Temperature 55.0 °F Coil Bypass Factor 0.100 Cooling Source Air -Cooled DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 86.9 °F Heating Source Combustion - Natural Gas Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw-thru Fan Performance 1.75 in wg Overall Efficiency 54 % Fan Control 2 -speed fan cooling, 1 -speed fan heating Low Speed Fan Airflow 67 % Duct System Data: Supply Duct Data: Duct Heat Gain 3 % Duct Leakage 2 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 2 01-04 Conference x1 01-13 Copy/Mail Room x1 Thermostats and Zone Data: Zone Cooling T-Stat Occ. (°F) Cooling T-Stat Unocc. (°F) Heating T-Stat Occ. (°F) Heating T-Stat Unocc. (°F) T-Stat Throttling Range (°F) Diversity Factor (%) Direct Exhaust Airflow (CFM) Direct Exhaust Fan (kW) 1 75.0 80.0 72.0 55.0 1.50 100 0.0 0.0 Thermostat Schedule 90.1 Office HVAC Unoccupied Cooling is Available Supply Terminals Data: Hourly Analysis Program 5.10 Page 3 of 10 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP RTU -R02 Input Data 11/30/2017 01:19PM Zone Terminal Type Air Distribution Air Distribution Effectiveness Specification Air Distribution Effectiveness Minimum Airflow Fan Performance Fan Efficiency Design Supply Temp. 1 Diffuser (no reheat) Ceiling supply / ceiling return ASHRAE 62.1 1 0.30 CFM/ft2 - - - Zone Heating Units: Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer -Generated): System Sizing Data: Sizing Data: Cooling Supply Temperature 55.0 °F Supply Fan Airflow 480.3 CFM Ventilation Airflow 105.1 CFM Heating Supply Temperature 86.9 °F Hydronic Sizing Specifications: Chilled Water Delta -T 10.0 °F Hot Water Delta -T 20.0 °F Safety Factors: Cooling Sensible 0 Cooling Latent 0 % Heating 0 Zone Sizing Data: Zone Airflow Sizing Method Sum of space airflow rates Space Airflow Sizing Method Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 470.7 - - 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load 15.7 MBH Design OAT 95.0 °F Equipment Sizing User -Defined Gross Cooling Capacity 1.0 MBH Compressor & OD Fan Power 1.000 kW DX System Configuration 1 -stage compression, 1 circuit Conventional Cutoff OAT 55.0 °F Low Temperature Operation Not used Central Heating Unit - Combustion Estimated Maximum Load 8.9 MBH Equipment Sizing User -Defined Gross Heating Capacity 1.0 MBH Average Efficiency 85.0 % Misc. Electric 0.000 kW Hourly Analysis Program 5.10 Page 4 of 10 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP RTU -R03 Input Data 11/30/2017 01:19PM 1. General Details: Air System Name RTU -R03 Equipment Type Air System Type Number of zones Packaged Rooftop Units Single Zone CAV 1 2. Ventilation System Components: Ventilation Air Data: Airflow Control Ventilation Sizing Method Unocc. Damper Position Damper Leak Rate 5 % Outdoor Air CO2 Level 400 ppm Constant Ventilation Airflow ASHRAE Std 62.1-2010 Closed Economizer Data: Control Integrated enthalpy control Upper Cutoff 75.0 °F Lower Cutoff 35.0 °F Central Cooling Data: Supply Air Temperature 55.0 °F Coil Bypass Factor 0.100 Cooling Source Air -Cooled DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 86.9 °F Heating Source Combustion - Natural Gas Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw-thru Fan Performance 1.75 in wg Overall Efficiency 54 % Fan Control 2 -speed fan cooling, 1 -speed fan heating Low Speed Fan Airflow 67 % Duct System Data: Supply Duct Data: Duct Heat Gain 3 % Duct Leakage 2 % Return Duct or Plenum Data: Retum Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 3 01-01 E Conference x1 01-02 SE Open Office x1 Thermostats and Zone Data: Zone Cooling T-Stat Occ. (°F) Cooling T-Stat Unocc. (°F) Heating T-Stat Occ. (°F) Heating T-Stat Unocc. (°F) T-Stat Throttling Range (°F) Diversity Factor (%) Direct Exhaust Airflow (CFM) Direct Exhaust Fan (kW) 1 75.0 80.0 72.0 55.0 1.50 100 0.0 0.0 Thermostat Schedule 90.1 Office HVAC Unoccupied Cooling is Available Supply Terminals Data: Hourly Analysis Program 5.10 Page 5 of 10 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP RTU -R03 Input Data 11/30/2017 01:19PM Zone Terminal Type Air Distribution Air Distribution Effectiveness Specification Air Distribution Effectiveness Minimum Airflow Fan Performance Fan Efficiency Design Supply Temp. 1 Diffuser (no reheat) Ceiling supply / ceiling return ASHRAE 62.1 1 0.30 CFM/ft2 - - - Zone Heating Units: Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer -Generated): System Sizing Data: Sizing Data: Cooling Supply Temperature 55.0 °F Supply Fan Airflow 948.0 CFM Ventilation Airflow 173.6 CFM Heating Supply Temperature 86.9 °F Hydronic Sizing Specifications: Chilled Water Delta -T 10.0 °F Hot Water Delta -T 20.0 °F Safety Factors: Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Sum of space airflow rates Space Airflow Sizing Method Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 929.0 - - 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load 29.3 MBH Design OAT 95.0 °F Equipment Sizing User -Defined Gross Cooling Capacity 1.0 MBH Compressor & OD Fan Power ,____ 1.000 kW DX System Configuration 1 -stage compression, 1 circuit Conventional Cutoff OAT 55.0 °F Low Temperature Operation Not used Central Heating Unit - Combustion Estimated Maximum Load 22.5 MBH Equipment Sizing User -Defined Gross Heating Capacity 1.0 MBH Average Efficiency 85.0 % Misc. Electric 0.000 kW Hourly Analysis Program 5.10 Page 6 of 10 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP RTU -R04 Input Data 11/30/2017 01:19PM 1. General Details: Air System Name RTU -R04 Equipment Type Air System Type Number of zones 1 Packaged Rooftop Units Single Zone CAV 2. Ventilation System Components: Ventilation Air Data: Airflow Control Ventilation Sizing Method Unocc. Damper Position Damper Leak Rate 5 % Outdoor Air CO2 Level 400 ppm Constant Ventilation Airflow ASHRAE Std 62.1-2010 Closed Economizer Data: Control Integrated enthalpy control Upper Cutoff 75.0 °F Lower Cutoff 35.0 °F Central Cooling Data: Supply Air Temperature 55.0 °F Coil Bypass Factor 0.100 Cooling Source Air -Cooled DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 86.9 °F Heating Source Combustion - Natural Gas Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw-thru Fan Performance 1.75 in wg Overall Efficiency 54 % Fan Control 2 -speed fan cooling, 1 -speed fan heating Low Speed Fan Airflow 67 % Duct System Data: Supply Duct Data: Duct Heat Gain 3 % Duct Leakage 2 % Return Duct or Plenum Data: Return Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 4 Cooling T-Stat Occ. (°F) 01-08 Open Office x1 01-09 Conference x1 01-10 Telephone Room x1 01-11 Telephone Room x1 01-12 Conference x1 Thermostats and Zone Data: Zone Cooling T-Stat Occ. (°F) Cooling T-Stat Unocc. (°F) Heating T-Stat Occ. (°F) Heating T-Stat Unocc. (°F) T-Stat Throttling Range (°F) Diversity Factor (%) Direct Exhaust Airflow (CFM) Direct Exhaust Fan (kW) 1 75.0 80.0 72.0 55.0 1.50 100 0.0 0.0 Thermostat Schedule 90.1 Office HVAC Unoccupied Cooling is Available Supply Terminals Data: Hourly Analysis Program 5.10 Page 7 of 10 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP RTU -R04 Input Data 11/30/2017 01:19PM Zone Terminal Type Air Distribution Air Distribution Effectiveness Specification Air Distribution Effectiveness Minimum Airflow Fan Performance Fan Efficiency Design Supply Temp. 1 Diffuser (no reheat) Ceiling supply / ceiling retum ASHRAE 62.1 1 0.30 CFM/ft2 - - - Zone Heating Units: Zone Unit Heat Source Electric Resistance, Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer -Generated): System Sizing Data: Sizing Data: Cooling Supply Temperature 55.0 °F Supply Fan Airflow 1814.3 CFM Ventilation Airflow 449.9 CFM Heating Supply Temperature 86.9 °F Hydronic Sizing Specifications: Chilled Water Delta -T 10.0 °F Hot Water Delta -T 20.0 °F Safety Factors: Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Sum of space airflow rates Space Airflow Sizing Method Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 1778.0 - - 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load 59.6 MBH Design OAT 95.0 °F Equipment Sizing User -Defined Gross Cooling Capacity 1.0 MBH Compressor & OD Fan Power 1.000 kW DX System Configuration 1 -stage compression, 1 circuit Conventional Cutoff OAT 55.0 °F Low Temperature Operation Not used Central Heating Unit - Combustion Estimated Maximum Load 29.4 MBH Equipment Sizing User -Defined Gross Heating Capacity 1.0 MBH Average Efficiency 85.0 % Misc. Electric 0.000 kW Hourly Analysis Program 5.10 Page 8 of 10 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP RTU -R05 Input Data 11/30/2017 01:19PM 1. General Details: Air System Name RTU -R05 Equipment Type Packaged Rooftop Units Air System Type Single Zone CAV Number of zones 1 2. Ventilation System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Ventilation Sizing Method ASHRAE Std 62.1-2010 Unocc. Damper Position Closed Damper Leak Rate 5 % Outdoor Air CO2 Level 400 ppm Economizer Data: Control Integrated enthalpy control Upper Cutoff 75.0 °F Lower Cutoff 35.0 °F Central Cooling Data: Supply Air Temperature 55.0 °F Coil Bypass Factor 0.100 Cooling Source Air -Cooled DX Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 86.9 °F Heating Source Combustion - Natural Gas Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw-thru Fan Performance 1.75 in wg Overall Efficiency 54 % Fan Control 2 -speed fan cooling, 1 -speed fan heating Low Speed Fan Airflow 67 % Duct System Data: Supply Duct Data: Duct Heat Gain 3 % Duct Leakage 2 % Return Duct or Plenum Data: Retum Air Via Ducted Return 3. Zone Components: Space Assignments: Zone 1: Zone 5 01-03 SW Open Office x1 Thermostats and Zone Data: Zone Cooling T-Stat Occ. (°F) Cooling T-Stat Unocc. (°F) Heating T-Stat Occ. (°F) Heating T-Stat Unocc. (°F) T-Stat Throttling Range (°F) Diversity Factor (%) Direct Exhaust Airflow (CFM) Direct Exhaust Fan (kW) 1 75.0 80.0 72.0 55.0 1.50 100 0.0 0.0 Thermos at Schedule 90.1 Office HVAC Unoccupied Cooling is Available Supply Terminals Data: Hourly Analysis Program 5.10 Page 9 of 10 Air Distribution Air Design Air Effectiveness Distribution Fan Supply Zone Terminal Type Distribution Specification Effectiveness Minimum Airflow Fan Performance Efficiency Temp. Hourly Analysis Program 5.10 Page 9 of 10 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP RTU -R05 Input Data 11/30/2017 01:19PM 1 Diffuser (no reheat) Ceiling supply / ceiling retum ASHRAE 62.1 1 0.30 CFM/ft2 Zone Heating Units: Zone Unit Heat Source Electric Resistance Zone Heating Unit Schedule JFMAMJJASOND 4. Sizing Data (Computer -Generated): System Sizing Data: Sizing Data: Cooling Supply Temperature 55.0 °F Supply Fan Airflow 1888.3 CFM Ventilation Airflow 122.9 CFM Heating Supply Temperature 86.9 °F Hydronic Sizing Specifications: Chilled Water Delta -T 10.0 °F Hot Water Delta -T 20.0 °F Safety Factors: Cooling Sensible 0 % Cooling Latent 0 % Heating 0 % Zone Sizing Data: Zone Airflow Sizing Method Sum of space airflow rates Space Airflow Sizing Method Individual peak space Toads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 1850.5 - - 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load 47.6 MBH Design OAT 95.0 °F Equipment Sizing User -Defined Gross Cooling Capacity 1.0 MBH Compressor & OD Fan Power 1.000 kW DX System Configuration 1 -stage compression, 1 circuit Conventional Cutoff OAT 55.0 °F Low Temperature Operation Not used Central Heating Unit - Combustion Estimated Maximum Load 31.6 MBH Equipment Sizing User -Defined Gross Heating Capacity 1.0 MBH Average Efficiency 85.0 Misc. Electric 0.000 kW Hourly Analysis Program 5.10 Page 10 of 10 Hermanson SYSTEM OUTPUT DATA System Loads Carrier HAP Version 5.1 Air System Sizing Summary for RTU -R01 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Air System Information Air System Name RTU -R01 Equipment Class PKG ROOF Air System Type SZCAV Number of zones 1 Floor Area 2040.0 ft2 Location Seattle IAP, Washington Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 3.5 Tons Load occurs at Jul 1500 Total coil load 42.5 MBH OA DB / WB 86.0 / 67.0 °F Sensible coil load 35.0 MBH Entering DB / WB 78.0 / 63.3 °F Coil CFM at Jul 1500 1327 CFM Leaving DB / WB 53.2 / 51.9 °F Max block CFM 1327 CFM Coil ADP 50.4 °F Sum of peak zone CFM 1327 CFM Bypass Factor 0.100 Sensible heat ratio 0.825 Resulting RH 46 % CFM/Ton 375.0 Design supply temp. 55.0 °F ft2/Ton 576.2 Zone T -stat Check 1 of 1 OK BTU/(hr•ft2) 20.8 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 23.3 MBH Load occurs at Des Htg Coil CFM at Des Htg 1327 CFM BTU/(hrft2) 11.4 Max coil CFM 1327 CFM Ent. DB / Lvg DB 61.7 / 78.2 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 1327 CFM Fan motor BHP 0.64 BHP Standard CFM 1306 CFM Fan motor kW 0.50 kW Actual max CFM/ft2 0.65 CFM/ft2 Fan static 1.75 in wg Outdoor Ventilation Air Data Design airflow CFM 277 CFM CFM/person 9.23 CFM/person CFM/ft2 0.14 CFM/ft2 Hourly Analysis Program 5.10 Page 1 of 20 Zone Sizing Summary for RTU -R01 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Air System Information Air System Name RTU -R01 Equipment Class PKG ROOF Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 2040.0 ft2 Location Seattle IAP, Washington Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 1301 1301 0.64 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 27.5 Jul 1800 10.7 2040.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 01-05 Open Office 1 24.2 Jul 1800 1138 9.5 . 1835.0 0.62 01-06 Enclosed Office 1 1.3 Jul 1800 66 1.0 90.0 0.73 01-07 Meeting 1 2.1 Jul 2100 97 0.2 115.0 0.85 Hourly Analysis Program 5.10 Page 2 of 20 Ventilation Sizing Summary for RTU -R01 K_Catalyst Workplace Activation_v5_1 MANSON COMPANY LLP 3 Method ASHRAE Std 62.1-2010 Cooling operation ity (D) 1000 door Air Intake (Vou) 272 CFM )n Efficiency (Ev) 0.984 (Vot) 277 CFM tion Analysis )gram 5.10 Supply Air (CFM) Space Floor Area (ft2) Area Outdoor Air Rate (CFM/ft2) Time Averaged Occupancy (Occupants) People Outdoor Air Rate (CFM/person) Air Distribution Effectiveness Space Outdoor Air (CFM) Breathing Zone Outdoor Air (CFM) Spa( Ventilatic Efficieni :e Name Mult. (Vpz) (Az) (Ra) (Pz) (Rp) (Ez) (Voz) (Vbz) (Ev ce 1 1138 1835.0 0.06 26.0 5.00 1.0 240 240 0.9E Office 1 66 90.0 0.06 1.0 5.00 1.0 10 10 1.0! 1 97 115.0 0.06 3.0 5.00 1.0 22 22 0.9E e Multipliers) 1301 272 0.91 )gram 5.10 Air System Design Load Summary for RTU -R01 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Hourly Analysis Program 5.10 Page 4 of 20 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 86.0 °F / 67.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 2040 ft2 1002 - 2040 ft2 2935 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 2040 ft2 0 - 2040 ft2 0 - Partitions 1386 ft2 2734 - 1386 ft2 7775 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1961 W 6087 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 3295 W 10790 - 0 0 - People 30 6181 6150 0 0 0 Infiltration - 0 0- 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 26794 6150 - 10710 0 Zone Conditioning - 29541 6150 - 10691 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 1327 CFM 0 - 1327 CFM 0 - Ventilation Load 277 CFM 2962 1304 277 CFM 13993 0 Supply Fan Load 1327 CFM 1722 - 1327 CFM -1722 - Space Fan Coil Fans - 0 -- 0 - Duct Heat Gain / Loss 3% 804 - 3% 321 - » Total System Loads - 35028 7454 - 23283 0 Central Cooling Coil - 35028 7455 - 0 0 Central Heating Coil- 0 - - 23283 - » Total Conditioning - 35028 7455 - 23283 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.10 Page 4 of 20 Air System Sizing Summary for RTU -R02 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP. 11/30/2017 01:20PM Air System Information Air System Name RTU -R02 Equipment Class PKG ROOF Air System Type SZCAV Number of zones 1 Floor Area 520.0 ft2 Location Seattle IAP, Washington Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space Toads Central Cooling Coil Sizing Data Total coil load 1.3 Tons Load occurs at Jul 1700 Total coil load 15.7 MBH OA DB / WB 84.2 / 66.4 °F Sensible coil load 12.4 MBH Entering DB / WB 77.6 / 63.5 °F Coil CFM at Jul 1700 480 CFM Leaving DB / WB 53.2 / 52.0 °F Max block CFM 480 CFM Coil ADP 50.5 °F Sum of peak zone CFM 480 CFM Bypass Factor 0.100 Sensible heat ratio 0.795 Resulting RH 48 % CFM/Ton 368.2 Design supply temp. 55.0 °F ft2/Ton 398.7 Zone T -stat Check 1 of 1 OK BTU/(hrft2) 30.1 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise ' N/A Central Heating Coil Sizing Data Max coil load 8.9 MBH Load occurs at Des Htg Coil CFM at Des Htg 480 CFM BTU/(hrft2) 17.2 Max coil CFM 480 CFM Ent. DB / Lvg DB 61.0 / 78.5 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 480 CFM Fan motor BHP 0.23 BHP Standard CFM 473 CFM Fan motor kW 0.18 kW Actual max CFM/ft2 0.92 CFM/ft2 Fan static 1.75 in wg Outdoor Ventilation Air Data Design airflow CFM 105 CFM CFM/person 7.51 CFM/person CFM/ft2 0.20 CFM/ft2 Hourly Analysis Program 5.10 Page 5 of 20 Zone Sizing Summary for RTU -R02 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Air System Information Air System Name RTU -R02 Equipment Class PKG ROOF Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 520.0 ft2 Location Seattle IAP, Washington Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 2 471 471 0.91 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 2 10.0 Jul 1800 4.4 520.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 2 01-04 Conference 1 7.9 Jul 1800 371 4.2 395.0 0.94 01-13 Copy/Mail Room 1 2.1 Jul 2000 99 0.2 125.0 0.79 Hourly Analysis Program 5.10 Page 6 of 20 Ventilation Sizing Summary for RTU -R02 K_Catalyst Workplace Activation_v5_1 MANSON COMPANY LLP 1 Method ASHRAE Std 62.1-2010 Cooling operation ity (D) 1.000 door Air Intake (Vou) 101 CFM 3 Efficiency (Ev) 0.963 (Vot) 105 CFM tion Analysis )gram 5.10 Supply Air (CFM) Space Floor Area (ft2) Area Outdoor Air Rate (CFM/ft2) Time Averaged Occupancy (Occupants) People Outdoor Air Rate (CFM/person) Air Distribution Effectiveness Space Outdoor Air (CFM) Breathing Zone Outdoor Air (CFM) Spa( Ventilatic Efficient se Name Mult. (Vpz) (Az) (Ra) (Pz) (Rp) (Ez) (Voz) (Vbz) (Ev 1)e 1 371 395.0 0.06 14.0 5.00 1.0 94 94 0.9( I Room 1 99 125.0 0.06 0.0 5.00 1.0 8 8 1.1i e Multipliers) 471 101 0.91 )gram 5.10 Air System Design Load Summary for RTU -R02 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Hourly Analysis Program 5.10 Page 8 of 20 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1700 COOLING OA DB / WB 84.2 °F / 66.4 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 520 ft2 313 - 520 ft2 748 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 520 ft2 0 - 520 ft2 0 - Partitions 647 ft2 1304 - 647 ft2 3630 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 500 W 1571 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 1150 W 3786 - 0 0 - People 14 2954 2870 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 9928 2870 - 4378 0 Zone Conditioning - 10591 2870 - 4133 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 480 CFM 0 - 480 CFM 0 - Ventilation Load 105 CFM 935 333 105 CFM 5292 0 Supply Fan Load 480 CFM 623 - 480 CFM -623 - Space Fan Coil Fans- 0 - - 0 - Duct Heat Gain / Loss 3% 298 - 3% 131 - » Total System Loads - 12447 3203 - 8933 0 Central Cooling Coil - 12447 3203 - 0 0 Central Heating Coil - 0 - - 8933 - » Total Conditioning - 12447 3203 - 8933 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.10 Page 8 of 20 Air System Sizing Summary for RTU -R03 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Air System Information Air System Name RTU -R03 Equipment Class PKG ROOF Air System Type SZCAV Number of zones 1 Floor Area 920.0 ft2 Location Seattle IAP, Washington Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.4 Tons Load occurs at Aug 1500 Total coil load 29.3 MBH OA DB / WB 86.0 / 67.0 °F Sensible coil load 24.1 MBH Entering DB / WB 77.7 / 63.5 °F Coil CFM at Aug 1500 948 CFM Leaving DB / WB 53.9 / 52.6 °F Max block CFM 948 CFM Coil ADP 51.2 °F Sum of peak zone CFM 948 CFM Bypass Factor 0.100 Sensible heat ratio 0.820 Resulting RH 48 % CFM/Ton 387.8 Design supply temp. 55.0 °F ft2/Ton 376.3 Zone T -stat Check 1 of 1 OK BTU/(hrft2) 31.9 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 22.5 MBH Load occurs at Des Htg Coil CFM at Des Htg 948 CFM BTU/(hrft2) 24.4 Max coil CFM 948 CFM Ent. DB / Lvg DB 62.5 / 84.8 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 948 CFM Fan motor BHP 0.45 BHP Standard CFM 933 CFM Fan motor kW 0.36 kW Actual max CFM/ft2 1.03 CFM/ft2 Fan static 1.75 in wg Outdoor Ventilation Air Data Design airflow CFM 174 CFM CFM/person 7.55 CFM/person CFM/ft2 0.19 CFM/ft2 Hourly Analysis Program 5.10 Page 9 of 20 Zone Sizing Summary for RTU -R03 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Air System Information Air System Name RTU -R03 Equipment Class PKG ROOF Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 920.0 ft2 Location Seattle IAP, Washington Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 3 929 929 1.01 0.0 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft.) Zone 3 19.1 Aug 1700 14.6 920.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft.) Space CFM/ft2 Zone 3 01-01 E Conference 1 5.7 Aug 1800 294 4.7 245.0 1.20 01-02 SE Open Office 1 13.5 Aug 1600 635 9.9 675.0 0.94 Hourly Analysis Program 5.10 Page 10 of 20 Ventilation Sizing Summary for RTU -R03 K_Catalyst Workplace Activation_v5_1 MANSON COMPANY LLP t Method ASHRAE Std 62.1-2010 Cooling operation ity (D) 1000 door Air Intake (Vou) 170 CFM jn Efficiency (Ev) 0.980 (Vot) 174 CFM tion Analysis )gram 5.10 Supply Air (CFM) Space Floor Area (ft2) Area Outdoor Air Rate (CFM/ft2) Time Averaged Occupancy (Occupants) People Outdoor Air Rate (CFM/person) Air Distribution Effectiveness Space Outdoor Air (CFM) Breathing Zone Outdoor Air (CFM) Spat Ventilatic Efficien4 :e Name Mult. (Vpz) (Az) (Ra) (Pz) (Rp) (Ez) (Voz) (Vbz) (Ev :rice 1 294 245.0 0.06 9.0 5.00 1.0 60 60 0.9 Office 1 635 675.0 0.06 14.0 5.00 1.0 111 111 1.0( e Multipliers) 929 170 0.91 )gram 5.10 Air System Design Load Summary for RTU -R03 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Hourly Analysis Program 5.10 Page 12 of 20 DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1500 COOLING OA DB / WB 86.0 °F / 67.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 36 ft' 1309 - 36 ft2 - - Wall Transmission 1021 ft' 2457 - 1021 ft' 5541 - Roof Transmission 920 ft' 389 - 920 ft' 1323 - Window Transmission 36 ft' 171 - 36 ft' 1064 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads . 21 ft' 60 - 21 ft2 373 - Floor Transmission 920 ft2 0 - 920 ft2 1249 - Partitions 193 ft' 384 - 193 ft' 1093 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 884 W 2745 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 2040 W 6680 - 0 0 - People 23 4739 4715 0 0 0 Infiltration - 0 0 - 3910 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 18935 4715 - 14554 0 Zone Conditioning - 20389 4715 - 14555 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 948 CFM 0 - 948 CFM 0 - Ventilation Load 174 CFM 1864 569 174 CFM 8691 0 Supply Fan Load 948 CFM 1230 - 948 CFM -1230 - Space Fan Coil Fans - 0 -- 0 - Duct Heat Gain / Loss 3% 568 - 3% 437 - » Total System Loads - 24050 5284 - 22452 0 Central Cooling Coil- 24050 5285 - 0 0 Central Heating Coil- 0 - - 22452 - » Total Conditioning - 24050 5285 - 22452 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.10 Page 12 of 20 Air System Sizing Summary for RTU -R04 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Air System Information Air System Name RTU -R04 Equipment Class PKG ROOF Air System Type SZCAV Number of zones 1 Floor Area 3740.0 ft2 Location Seattle IAP, Washington Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 5.0 Tons Load occurs at Aug 1500 Total coil load 59.6 MBH OA DB / WB 86.0 / 67.0 °F Sensible coil load 49.2 MBH Entering DB / WB 78.7 / 63.5 °F Coil CFM at Aug 1500 1814 CFM Leaving DB / WB 53.2 / 51.8 °F Max block CFM 1814 CFM Coil ADP 50.4 °F Sum of peak zone CFM 1814 CFM Bypass Factor 0.100 Sensible heat ratio 0.825 Resulting RH 45 % CFM/Ton 365.2 Design supply temp. 55.0 °F ft2/Ton 752.8 Zone T -stat Check 0 of 1 OK BTU/(hr•ft2) 15.9 Max zone temperature deviation 0.3 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 29.4 MBH Load occurs at Des Htg Coil CFM at Des Htg 1814 CFM BTU/(hrft2) 7.9 Max coil CFM 1814 CFM Ent. DB / Lvg DB 59.9 / 75.2 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 1814 CFM Fan motor BHP 0.87 BHP Standard CFM 1785 CFM Fan motor kW 0.69 kW Actual max CFM/ft2 0.49 CFM/ft2 Fan static 1.75 in wg Outdoor Ventilation Air Data Design airflow CFM 450 CFM CFM/person 11.25 CFM/person CFM/ft2 0.12 CFM/ft2 Hourly Analysis Program 5.10 Page 13 of 20 Zone Sizing Summary for RTU -R04 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Air System Information Air System Name RTU -R04 Equipment Class PKG ROOF Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 3740.0 ft2 Location Seattle IAP, Washington Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 4 1778 1778 0.48 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 4 37.6 Aug 1600 8.8 3740.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 4 01-08 Open Office 1 32.2 Aug 1600 1517 8.4 3450.0 0.44 01-09 Conference 1 2.2 Jul 2100 104 0.1 95.0 1.10 01-10 Telephone Room 1 0.5 Jul 2100 24 0.1 35.0 0.69 01-11 Telephone Room 1 0.5 Jul 2100 24 0.1 35.0 0.69 01-12 Conference 1 2.3 Jul 2100 109 0.2 . 125.0 0.87 Hourly Analysis Program 5.10 Page 14 of 20 Ventilation Sizing Summary for RTU -R04 K_Catalyst Workplace Activation_v5_1 MANSON COMPANY LLP 3 Method ASHRAE Std 62.1-2010 Cooling operation ity (D) 1.000 door Air Intake (Vou) 424 CFM 3n Efficiency (Ev) 0.943 (Vot) 450 CFM tion Analysis )gram 5.10 Supply Air (CFM) Space Floor Area (ft2) Area Outdoor Air Rate (CFM/ft2) Time Averaged Occupancy (Occupants) People Outdoor Air Rate (CFM/person) Air Distribution Effectiveness Space Outdoor Air (CFM) Breathing Zone Outdoor Air (CFM) Spa( Ventilatic Efficieni :e Name Mult. (Vpz) (Az) (Ra) (Pz) (Rp) (Ez) (Voz) (Vbz) (Ev ce 1 1517 3450.0 0.06 30.0 5.00 1.0 357 357 1.0( :e 1 104 95.0 0.06 4.0 5.00 1.0 26 26 0.9( a Room 1 24 35.0 0.06 1.0 5.00 1.0 7 7 0.9, 3 Room 1 24 35.0 0.06 1.0 5.00 1.0 7 7 0.9, :e 1 109 125.0 0.06 4.0 5.00 1.0 28 28 0.9E e Multipliers) 1778 424 0.94 )gram 5.10 Air System Design Load Summary for RTU -R04 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Hourly Analysis Program 5.10 Page 16 of 20 DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1500 COOLING OA DB / WB 86.0 °F / 67.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 100 ft2 5265 - 100 ft2 - - Wall Transmission 85 ft2 130 - 85 ft2 461 - Roof Transmission 3740 ft2 1582 - 3740 ft2 5380 - Window Transmission 100 ft2 473 - 100 ft2 2939 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 3740 ft2 0 - 3740 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 3595 W 11159 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 3120 W 10217 - 0 0 - People 40 8242 8200 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous- 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 37068 8200 - 8780 0 Zone Conditioning- 41103 8200 - 8664 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 1814 CFM 0 - 1814 CFM 0 - Ventilation Load 450 CFM 4633 2217 450 CFM 22854 0 Supply Fan Load 1814 CFM 2354 - 1814 CFM -2354 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 3% 1112 - 3% 263 - » Total System Loads - 49202 10417 - 29427 0 Central Cooling Coil - 49202 10417 - 0 0 Central Heating Coil- 0 - - 29427 - » Total Conditioning - 49202 10417 - 29427 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg Toads Hourly Analysis Program 5.10 Page 16 of 20 Air System Sizing Summary for RTU -R05 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Air System Information Air System Name RTU -R05 Equipment Class PKG ROOF Air System Type SZCAV Number of zones 1 Floor Area 715.0 ft2 Location Seattle IAP, Washington Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space Toads Central Cooling Coil Sizing Data Total coil load 4.0 Tons Load occurs at Sep 1500 Total coil load 47.6 MBH OA DB / WB 84.0 / 66.0 °F Sensible coil load 43.8 MBH Entering DB / WB 76.5 / 62.3 °F Coil CFM at Sep 1500 1888 CFM Leaving DB / WB 54.7 / 53.3 °F Max block CFM 1888 CFM Coil ADP 52.2 °F Sum of peak zone CFM 1888 CFM Bypass Factor 0.100 Sensible heat ratio 0.920 Resulting RH 45 % CFM/Ton 476.0 Design supply temp. 55.0 °F ft2/Ton 180.2 Zone T -stat Check 1 of 1 OK BTU/(hrft2) 66.6 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 31.6 MBH Load occurs at Des Htg Coil CFM at Des Htg 1888 CFM BTU/(hrft2) 44.2 Max coil CFM 1888 CFM Ent. DB / Lvg DB 67.8 / 83.5 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 1888 CFM Fan motor BHP 0.90 BHP Standard CFM 1858 CFM Fan motor kW 0.72 kW Actual max CFM/ft2 2.64 CFM/ft2 Fan static 1.75 in wg Outdoor Ventilation Air Data Design airflow CFM 123 CFM CFM/person 7.68 CFM/person CFM/ft2 0.17 CFM/ft2 Hourly Analysis Program 5.10 Page 17 of 20 Zone Sizing Summary for RTU -R05 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Air System Information Air System Name RTU -R05 Equipment Class PKG ROOF Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 715.0 ft2 Location Seattle IAP, Washington Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 5 1851 1851 2.59 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 5 39.3 Sep 1500 27.9 715.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 5 01-03 SW Open Office 1 39.3 Sep 1500 1851 27.9 715.0 2.59 Hourly Analysis Program 5.10 Page 18 of 20 Ventilation Sizing Summary for RTU -R05 K_Catalyst Workplace Activation_v5_1 MANSON COMPANY LLP Method ASHRAE Std 62.1-2010 1 Cooling operation ity (D) 1000 door Air Intake (Vou) 123 CFM Jn Efficiency (Ev) 1.000 (Vot) 123 CFM tion Analysis )gram 5.10 Supply Air (CFM) Space Floor Area (ft2) Area Outdoor Air Rate (CFM/ft2) Time Averaged Occupancy (Occupants) People Outdoor Air Rate (CFM/person) Air Distribution Effectiveness Space Outdoor Air (CFM) Breathing Zone Outdoor Air (CFM) Spa Ventilatic Efficieni :e Name Mult. (Vpz) (Az) (Ra) (Pz) (Rp) (Ez) (Voz) (Vbz) (Ev Office 1 1851 715.0 0.06 16.0 5.00 1.0 123 123 1.0( e Multipliers) 1851 123 1.01 )gram 5.10 Air System Design Load Summary for RTU -R05 Project Name: TUK_Catalyst Workplace Activation_v5_1 Prepared by: HERMANSON COMPANY LLP 11/30/2017 01:20PM Hourly Analysis Program 5.10 Page 20 of 20 DESIGN COOLING DESIGN HEATING COOLING DATA AT Sep 1500 COOLING OA DB / WB 84.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB 1 WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 500 ft2 28672 - 500 ft2 - - Wall Transmission 1273 ft2 1891 - 1273 ft2 6909 - Roof Transmission 715 ft2 183 - 715 ft2 1029 - Window Transmission 500 ft2 1752 - 500 ft2 14695 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 42 ft2 89 - 42 ft2 746 - Floor Transmission 715 ft2 0 - 715 ft2 1466 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 687 W 2133 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 400 W 1310 - 0 0 - People 16 3297 3280 0 0 0 Infiltration - 0 0 - 3039 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 39327 3280 - 27883 0 Zone Conditioning- 39122 3280 - 27076 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 1888 CFM 0 - 1888 CFM 0 - Ventilation Load 123 CFM 1048 520 123 CFM 6114 0 Supply Fan Load 1888 CFM 2450 - 1888 CFM -2450 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 3% 1180 - 3% 836 - » Total System Loads - 43799 3800 - 31576 0 Central Cooling Coil- 43799 3803 - 0 0 Central Heating Coil- 0 - - 31576 - » Total Conditioning - 43799 3803 - 31576 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program 5.10 Page 20 of 20 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIF PERMIT NUMBER: M17-0189 DATE: 12/04/17 PROJECT NAME: CATALYST WORKPLACE SITE ADDRESS: 10848 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: P/J PAN& 141 4� Building Division Fire Prevention Planning Division Public Works Structural ❑ Permit Coordinator 0 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 12/05/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 01/02/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 HERMANSON COMPANY LLP Home Espanol Contact Safety & Health 0 Washington State Department of Labor & Industries Claims & Insurance Search L&I A -Z Index Help Workplace Rights HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLPJSEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No. 602 004 844 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County Business type Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HERMACLOO5BJ Effective — expiration 01/11/2000— 08/25/2018 Bond WESTERN SURETY CO Bond account no. 929381801 Received by L&I 12/01/2005 Active. Meets current requirements. $12,000.00 Effective date 01/01/2006 Expiration date Until Canceled Page 1 of 3 Mg L&1 Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 12/8/2017 10"o (d) A AC ACH ACT AD ADD'L AFF AEG AHU ALUM AMP/AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTUH CAP CBD CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DDC DEFL DEG DIA DMPR DN DOAS DWG EXH EA EAT EC EER EF EFF EL ELEC/ELECT EMCS ENT EQUIP ESP EXIST/(E) EXH F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GPM GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX HZ MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL CEILING TILE ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN / BLACK STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CALIBRATED BALANCING DAMPER CONTROLS CONTRACTOR CEILING DIFFUSER/CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT/CONNECTED/CONNECTION CONTINUOUS/CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC/CONDENSER UNIT DOMESTIC COLD WATER/CONDENSER WATER DUCTBOARD/DRY BULB/DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/DEGREES DIAMETER DAMPER DOWN DEDICATED OUTSIDE AIR SYSTEM DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL/ELECTRIC ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING EXHAUST FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE/SMOKE DAMPER FOOT/FEET FUTURE FACE VELOCITY GRILLE GAUGE/GALLON GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE/REGISTER/DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HERTZ BC CW D E EER MC N N WG PLV KW LAT LB/LBS LF/LIN FT LPG LPS LVG LWA LWG LWT MAX MAU MBH MCA MD MFR MISC MIN MPS MT MTD MUW NA NC NG/NGAS NIC NO NPW N -R OA/OSA OBD OD PCF PD PH POC P/PRESS PSI PSIG QTY R RA RD/RND REF REQ RESID RF RG RL RPM RS S SA SAT SD S/D S_C SEER SENS SL SM SPEC SO SOG SP SF SS STRUC TA TEMP TBD TOD TOS TOT TSP TSTAT TYP UH UNO V VD VEL VERT VFD VOL W WB WG W/ W/O W/SF WSEC NTERNATIONAL BUILDING CODE NDUSTRIAL COLD WATER NSIDE DIAMETER/DIMENSION NVERT ELEVATION NTEGRATED ENERGY EFFICIENCY RATIO NTERNATIONAL MECHANICAL CODE NCHES NCHES WATER GAUGE NTEGRATED PART LOAD VALUE KILOWATTS LEAVING AIR TEMPERATURE POUND/POUNDS LINEAL FOOT/FEET LIQUID PROPANE GAS LOW PRESSURE STEAM LEAVING SOUND POWER RATING LEVEL (IN DB) LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM MAKE UP AIR UNIT 1000 BRITISH THERMAL UNITS/HOUR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MANUFACTURER MISCELLANEOUS MINIMUM/MINUTE MEDIUM PRESSURE STEAM MOUNT MOUNTED MAKE-UP WATER NOT APPLICABLE NORMALLY CLOSED/NOISE CRITERIA NATURAL GAS NOT IN CONTRACT NORMALLY OPEN/NUMBER NON -POTABLE WATER NON-RESIDENTIAL OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIAMETER/DIMENSION POUNDS PER CUBIC FOOT PRESSURE DROP PHASE POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANTITY RETURN GRILLE/RELOCATED/RETURN RETURN AIR ROUND REFERENCE REQUIRED RESIDENTIAL RELIEF REFRIGERANT DISCHARGE GAS REFRIGERANT LIQUID REVOLUTIONS PER MINUTE REFRIGERANT SUCTION SUPPLY SUPPLY AIR SATURATION/SUPPLY AIR TEMPERATURE SMOKE DETECTOR SLIP & DRIVE CONNECTION SEATTLE CODE SEASONAL ENERGY EFFICIENCY RATING SENSIBLE SOUND LINED SHEETMETAL SPECIFICATION SCREENED OPENING SLAB ON GRADE STATIC PRESSURE SQUARE FEET STAINLESS STEEL STRUCTURAL TRANSFER AIR TEMPERATURE/TEMPORARY TO BE DETERMINED TOP OF DUCT TOP OF STEEL/TOP OF SLAB TOTAL TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNIT HEATER UNLESS NOTED OTHERWISE VOLT VOLUME DAMPER VELOCITY VERTICAL VARIABLE FREQUENCY DRIVE VOLUME WRAPPED DUCT WET BULB WATER GAUGE WITH WITHOUT WATTS PER SQUARE FOOT WASHINGTON STATE ENERGY CODE MECHANICAL LEGEND fio"xio"IXI •10"X10";) ,10"X 10" 4-10"x1017-1 10"X10"0 1-10"xio";,/ ,10"X10"n 1Q"0 10"0 10"0O )12"X10"oQ) h 12"X1O"� 10"o 1F 10 10"0J Jj 10"O1 •k 2 11 1> NrwVV% -1\r> RECT SUPPLY AIR DUCT UP/TOWARD RECT SUPPLY AIR DUCT DN/AWAY RECT EXHAUST OR RETURN DUCT UP/TOWARD RECT EXHAUST OR RETURN DUCT DN/AWAY ROUND DUCT - UP/TOWARD ROUND DUCT - DN/ AWAY FLATOVAL DUCT - UP/ TOWARD FLATOVAL DUCT - DN/ AWAY DUCT OVERLAP BOOT TAP 45' TAP VOLUME DAMPER CALIBRATED BALANCING DAMPER RISE(R) & DROP(D) TRANSITION TURNING VANES/SPLITTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW (FORCED AIR) 6_"X16"ODSLi lo CD1-100 8"0 T T'STAT/TEMP SENSOR H HUMIDITY SENSOR sD SMOKE DETECTOR sP STATIC PRESSURE SENSOR oU OCCUPANCY SENSOR COMBINATION FSD FIRE DAMPER SMOKE DAMPER MOTOR OPERATED DAMPER ACCESS DOORS SOUND TRAP FLEX CONNECTION ACOUSTICALLY LINED DUCT OD = OUTSIDE DIMENSIONS SL = SOUND LINING (THICKNESS) FABRIC DUCT CLEARANCE SUPPLY AIR DIFFUSER (WITH CORE BLANKOFF/ROTATE) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) REVISION CLOUD & TRIANGLE ROUND DUCT SYMBOL FLATOVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE -CFM SIZE z CARBON DIOXIDE SENSOR co CARBON MONOXIDE SENSOR ()SENSOR EXISTING DUCTWORK • DEMO DUCTWORK 4. 0 D z z z z 2-CHWS /CHWR-5 z- RL/RS5 2- NG -5 LPG -s z-CDWS /CDWR-5 z--HWS/HWR-5 z- COND -5 FOV -5 z-- FOS /FOR -s RDG-i ® z da z WALL -MOUNTED GRILLE PIPE ELBOW UP PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP PRESS REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY/RETURN REFRIGERANT LIQUID/SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY/RETURN HEATING WATER SUPPLY/RETURN CONDENSATE FUEL OIL VENT FUEL OIL SUPPLY/RETURN REFRIGERANT DISCHARGE GAS MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 WSEC, 2015 IMC, & & SIMILAR YEAR WAC 296-104 BOILER RULES. 2. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNO. 3. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNO. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE OUTSIDE DIMENSIONS BEFORE SOUND LINING HAS BEEN ACCOUNTED FOR (SOUND LINING ® 1", UNO) 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY VENTS, STREETS, LOADING DOCK, NEIGHBORING LOT LINES & FUEL BURNING EQUIPMENT OR 3 FEET BELOW OR 25' ABOVE ANY CONTAMINANT SOURCE WITHIN 10 FEET. 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING PER C403.3.1 & C403.2.4.7: - 0% TO 100% OF THE DESIGN SUPPLY AIR WITH FAULT DETECTION & DIAGNOSTIC REPORTING. - CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. - INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED CLASS 1 LOW LEAK (<4 CFM/SF ® 1" WG) DAMPERS (OR GRAVITY PER EXCEPTIONS IN C403.2.4.3) DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, UNO FOR SMOKE CONTROL SYSTEM OPERATION. 13. THE CONTROL SYSTEM SHALL MEET C403 AND BE PROGRAMMABLE, CAPABLE OF BEING SET FOR DIFFERENT DAY TYPES PER WEEK, DEADBAND SETTING OF AT LEAST 5'F (10'F FOR RESIDENTIAL), BETWEEN THE HEATING AND COOLING SETPOINTS AND SETBACK TEMPERATURES WITH OPTIMAL START CONTROL. CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF VARYING FLOWS AND RESETTING SUPPLY AIR & WATER TEMPERATURES BY REPRESENTATIVE BUILDING LOADS WHERE REQUIRED IN C403.4. 14. WHERE REQUIRED BY C408 RECORD DRAWINGS OF THE. ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED IN THE RETURN AIR, PER MECH CODE, SUCH AS HVAC EQUIPMENT DELIVERING (NOT EXHAUST) >2000 CFM (INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH A TOTAL SUPPLY >2000 CFM) OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, NOT IN SYSTEMS SERVING SINGLE ROOMS/SPACES. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. VAV BOX (WITH FAN) SHUTDOWN CAN BE THROUGH CONTROLS SYSTEM. 20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" OR PRESSURIZED SHAFTS/ROOMS, THE FOLLOWING SHALL OCCUR: - ALL VERTICAL JOINTS & CORNERS SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE CONSTRUCTION SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE. - ANY PENETRATIONS OF THE CONSTRUCTION (DUCTWORK CONDUIT PIPING ...) SHALL BE SEALED ON BOTH SIDES - ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS AND THRESHOLD SWEEPS, AND OPEN AGAINST THE DIRECTION OF PRESSURE. - USE SECTION 909.5 OF THE 2012 IBC FOR MAX ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. 23. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS USED DURING THE INSTALLATION/FINISH WORK SHALL MEET THE LEED REQUIREMENTS FOR IEQ. 24. MAXIMUM S(UL-181 ANDARD LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET; UP TO 25' MAXIMUM LENGTH IS ACCEPTABLE IF; REFER TOTINST LLATION SDETDAILS NOT "SUPPORTOREQIS REMENTSDFLEXIBLE DUCTEFFIAMEBSPREADMRNATINGI SHALLBBED< 2520 NOT EXCEED MOK RDEVELOPEDL. RATING SHALL BE < 50. USE THERMAFLEX MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 25. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. 26. C406 "ADDITIONAL ENERGY PACKAGE OPTIONS" AS APPLICABLE. DUCTI LAST UPDATED 07/11/16 DUCT TYPE DUCT LOCATION (IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM) INSULATION R -VALUE REMARKS SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: OUTSIDE BUILDING R-8 1,2,3 OUTSIDE AIR WITHIN CONDITIONED SPACE: INSIDE BUILDING SEE NOTES 4 & 5 1,2,3,4,5 SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING R-6 1,2 SUPPLY AIR <55° OR >105° WITHIN CONDITIONED SPACE R-3.3 1,2 1 REFER TO C403.2.8 FOR FURTHER REQUIREMENTS & ALSO R403 FOR RESIDENTIAL INSTALLATIONS 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.8.1 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (AND Z" THICK INSULATION MIN. TO PREVENT CONDENSATION ON DUCTS IN PLENUM UP TO THE HEATING OR COOLING EQUIPMENT) 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND <2,800 CFM SUPPLY AIR MINIMUM PIPE INSULATION LAST UPDATED: 07/11/16 FLUID DESIGN OPERATING TEMP °F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH) CONDUCTIVITY RANGE MEAN TEMP RATING °F <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION) N/A 0.21-0.27 75 0.5 1 0.5 0.5 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 <40 0.20-0.26 75 0.5 1.0 1.0 1.0 1.5 NOTE: * NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA. TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED SEE R403 FOR RESIDENTIAL INSTALLATIONS. ** DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION M0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC M0.01 SCHEDULE SHEET - HVAC M2.01 D PARTIAL 1ST FLOOR DEMO PLAN - HVAC M2.01 PARTIAL 1ST FLOOR PLAN - HVAC r--.._________________.... REVISIONS No changes shall i• f -n do to the scope of work withcu+l prior approve) of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees tSERARA I'" SIT 1 REQUIT* ? C'= Vii: ❑ Niectzanicai Iectrical lumbing Gas Piping City of Tukwila BLiII_I;IING DIVISION APN NUMBER 0323049164 Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ LEGAL DESCRIPTION PARCEL 2 OF TUKWILA BLA L08-023 REC #20080612900007 LOCATED IN W 1/2 OF SW 1/4 OF 03-23-04 CATALYST WORKPLACE ACTIVATION TI 10848 E. MARGINAL WAY S. TUKWILA, WA VICINITY MAP NO SCALE FILE COPY Permit NotV%I'I0`61 Plan review approval i3 subject to errors and omissions. Approval of constructi pn documents does net a Jtiorize the violation of any adopted coda or ordinanc o. Receipt of approved Field Copy and conditions is acknowizdged: 17-j 11 / 11 SITE MAP NO SCALE By: Date: CtyofTukwila BUILDING DIVISION CEIVED QF TUKWILA 042017 PERMIT CENTER I7- 0 1 8 9 ISSUE FOR PERMIT Revisions 12/01/17 TMP ISSUE FOR PERMIT No. Date By Description Design Design Team TMP Drawn FVP Checked DTN Pre -Construction Number 11-17-11513 Construction Number Issue Date 12/01/17 LEGEND, ABBREVIATION, GENERAL NOTES & SHEET INDEX - HVAC MO REVIEWED FOR MPLIANCE OVED E`'82017 ft -4 x-12 City of Tukwila BUILDING DIVISION PACKAGED AC UNIT SCHEDULE (EXISTNG) LAST UPDATED: 11/22/17 UNIT TAG LOCATION AREA SERVED BASIS OF DESIGN SUPPLY CFM OSA CFM ESP IN WG OSA °F MAT °F UNIT/DUCT SAT DB °F COOLING CAPACITY GAS HEATING CAPACITY SEER/ EER ELEC 6 SOUND dBA WEIGHT LBS REMARKS STAGES INPUT MBH OUTPUT MBH NG CONN DB WB COND DB DB WB TOTAL MBH SENS. MBH MCA V/PH RTU -R01 ROOF CONFERENCE GCS16-048 1600 280 0.50 82 66 95 78.0 63.0 55.0 47 34 1 75 60 0.50 10.3/9.5 12 460/3 82 500 1,2 RTU -R02 ROOF OPEN OFFICE TRANE 4YCC3030 1000 105 0.58 82 66 95 78.0 63.0 55,0 29 23 1 75 60.5 0.50 13/11 19 208/3 70 500 1,2 RTU -R03 ROOF OPEN OFFICE TRANE YCC030 1000 170 0.40 82 66 95 78.0 63.0 55.0 30 - - 40 32 - - 20 208/3 - - 1,2 RTU -R04 ROOF OPEN OFFICE TRANE YCD060 2000 495 0.50 82 66 95 78:0 63.0 55.0 60 - - 90 73 - - 16 460/3- - 1 2 RTU -R05 ROOF OPEN OFFICE GCS16-060 2000 130 0.50 82 66 95 78.0 63.0 55.0 59 43 1 75 60 0.50 10/8.9 16 460/3 82 530 1,2 GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC ..) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS REMARKS: 1 EXISTING UNIT 2 REBALANCE AIRFLOW AS SHOWN ON PLANS MODULAR DIFFUSER SCHEDULE LAST UPDATED: 11/28/17 UNIT TAG BASIS OF DESIGN TYPE NECK SIZE IN DIA MAX CFM CORE SIZE FACE SIZE NC MOUNTING MATERIAL REMARKS DT1 SHOEMAKER 700MA MODULAR 6 100 6 X 6 24 X 24 20 T -BAR STEEL 1,2,3,4,5 DT2 SHOEMAKER 700MA MODULAR 8 210 8 X 8 24 X 24 20 T -BAR STEEL 1,2,3,4,5 DT3 SHOEMAKER 700MA MODULAR 10 350 10 X 10 24 X 24 25 T -BAR STEEL 1,2,3,4,5 DT4 SHOEMAKER 700MA MODULAR 12 500 12 X 12 24 X 24 25 T -BAR STEEL 1,2,3,4,5 ALUMINUM 1, 2, 3/4, 5 R7 SHOEMAKER 600T 1,800 20 T -BAR 24 x 24 ALUMINUM 1, 2, 3/4, 5 GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION &INSTALL PER MANUFACTURERS REQUIREMENTS 1 RUN OUT SIZE SAME SIZE AS DIFFUSER NECK SIZE, U.N.O. ON DWGS. 2 ALL DIFFUSERS TO HAVE SIDE INLET SHEET METAL CAN PLENUM IF < 1.5 DIA STRAIGHT FLEX AVAILABLE FOR TOP INLET 3 ECCO MFG DIFFUSER CAN TO HAVE PERFORATED INTERIOR PLATE (AND 1" SOUNDLINING IF SPACE <_ NC -30 OR SAT < 55°F) 4 STANDARD WHITE POWDER COAT TRANSFER / RETURN 1 EXHAUST AIR GRILLES LAST UPDATED: 11/28/2017 UNIT TAG BASIS OF DESIGN MAX CFM NECK SIZE IN DIA MOUNTING FACE SIZE MATERIAL REMARKS R1 SHOEMAKER 600T 150 8 T -BAR 24 x 12 ALUMINUM 1, 2, 3/4, 5 R2 SHOEMAKER 600T 300 10 T -BAR 24 x 12 ALUMINUM 1, 2, 3/4, 5 R3 SHOEMAKER 600T 500 12 T -BAR 24 x 12 ALUMINUM 1, 2, 3/4, 5 R4 SHOEMAKER 600T 750 14 T -BAR 24 x 24 ALUMINUM 1, 2, 3/4, 5 R5 SHOEMAKER 600T 1,000 16 T -BAR 24 x 24 ALUMINUM 1, 2, 3/4, 5 R6 SHOEMAKER 600T 1,400 18 T -BAR 24 x 24 ALUMINUM 1, 2, 3/4, 5 R7 SHOEMAKER 600T 1,800 20 T -BAR 24 x 24 ALUMINUM 1, 2, 3/4, 5 GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION &INSTALL PER MANUFACTURERS REQUIREMENTS 1 RUNOUT SAME AS DWG NECK SIZE U.N.O. ON DWG 2 T -BAR LAY -IN 3 PROVIDE DUCTBOARD PLENUM 4 PROVIDE SHEETMETAL PLENUM 5 STANDARD SOFT WHITE FINISH Mr/ IP RECEIVED CITY OF TUKWILA DEC 04 2017 PERMIT CENTER ISSUE FOR PERMIT Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL005BJ CATALYST WORKPLACE ACTIVATION TI 10848 E. MARGINAL WAY S. TUKWILA, WA Revisions 12/01/17 TMP ISSUE FOR PERMIT No. Date By Description Design Design Team TMP Drawn FVP Checked DTN Pre—Construction Number 11-17-11513 Construction Number Issue Date 12/01/17 SCHEDULE SHEET - HVAC REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila BUILDING DIVISION M0 .01 23"X23"RA UP 19"X21"SA UP 12"0 r':._ 10 0 UP TO RTU -R01.... Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ CATALYST WORKPLACE ACTIVATION TI 10848 E. MARGINAL WAY S. TUKWILA, WA Revisions 12/01/17 TMP ISSUE FOR PERMIT No. Date By Description Design Design Team TMP Drawn FVP 23"X23"RA UP 19"X21"SA UP Checked DTN Pre -Construction Number 11-17-11513 Construction Number L-19 L-19 Issue Date 12/01/17 1►I►i L► • UP TO RTU -R05 PARTIAL 1ST FLOOR DEMO PLAN - HVAC RECEIVED CITY OF. TUKWILA DEC 0 4 2017 PERMIT CE EVIE D FOR E COIF, PLIANC APPR VED PARTIAL 1ST FLOOR DEMO PLAN - HVAC SCALE: 1/8" = 1'-0" DEC 0 2011 ISSUE FOR PERMIT City ofukwila BUILDINGIVIOIO!'1 FURNITURE STORAGE WAREHOUSE 0 RELOCATED--- EXIST T—STAT RELOCATED DIST T -STAT WALL DISPLAY PANEL DT1-100 UP TO ' RTU -R01 Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ 1600 CFM RAL. OPEI1 OFFICE 280 CFM ;280 CFM ;280 CFM 280 CFM: DT2-150 CATALYST WORKPLACE ACTIVATION TI 16"X18" R2-300 10848 E. MARGINAL WAY S. TUKWILA, WA UP TO RTU—R02 • DT3-235 14"X14". ..........._..._. EXISTING WATER FOUNTAIN / BOTTLE FILLING STATION DT2-155 DT2-155 Revisions DT2-155 L/COP ` RK/I_ VCT -1 150 CFM! 8"0 700 CFM GEN FA 1155 CFM 8"0 (E) DT3-235 OPEN OFFICE/ :MODULAR:. Tta.TEE:E::W.FLt. 1600 CFM DT1-50 DT1-50 6"0 12/01/17 TMP ISSUE FOR PERMIT No. Date By Description R5-1000 16"0 DT2-155 8"0 DT2-155 235 CFM Design Design Team TMP 23"X23"RA UP 19"X21 "SA UP Drawn FVP Checked DTN Pre—Construction Number 11-17-11513 DT2-155' 8"0 DT2-155 8"0 R5-1000 16"0(TYP 2) Construction Number 20X2 /.: • 22'X22"RA UP Issue Date 12/01/17 285 CFM DT3-285 10"0 DT3-285' 10"0 PARTIAL 1ST FLOOR PLAN - HVAC 285 CFM 285 CFM (E) CLOSE H CONSTRUCTION NOTE: Q1 MOUNT THERMOSTAT ON INSULATED SUB—BASE. PARTIAL 1ST FLOOR PLAN - HVAC SCALE: 1/4" = 1'-0" RECEIVED CITY OF KWILA DEC 0 017 PERMIT iNTER REVIEWI'D FOR CODE COW PLIANCE APPRC VED • ISSUE FOR PERMIT DEC of 2017 City of Tukwila BUILDING DIVISION