HomeMy WebLinkAboutPermit M17-0192 - JARED'S JEWELERS - ROOFTOP UNITSJARED'S JEWELERS 16840 SOUTHCENTER PKWY EXPIRED 07/23/18 M17-0192 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto://www.TukwilaWA.eov MECHANICAL PERMIT 2623049129 16840 SOUTHCENTER PKWY Project Name: JARED'S JEWELERS Permit Number: Issue Date: Permit Expires On: M 17-0192 1/24/2018 7/23/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: PARKWAY SQUARE L L C P 0 BOX 5003 , BELLEVUE, WA, 98009 JESSE SIMENSON PO BOX 29116 , BELLINGHAM, WA, 98228 NORTHSOUND REFRIGERATION INC PO BOX 29116 , BELLINGHAM, WA, 98228 NORTHRI898CG Phone: (360) 380-1381 Phone: (360) 380-1381 Expiration Date: 2/7/2019 DESCRIPTION OF WORK: REMOVAL OF 3 GAS/ELECT ROOFTOP UNITS AND REPJLACE W/NEW UNITS OF SAME SIZE (CAPACITY) W/CURB ADPT. Valuation of Work: $10,100.00 Type of Work: Fuel type: Fees Collected: $344.08 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-466: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: 117q, I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development perm nd agree to the conditions attached to this permit. Signature: Print Name: ease 1-t Date: /- 2L1C/ 4 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City.Ordinance #2437) 5: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 6: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 7: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 8: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 10: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: RTU curb installation must be inspected before RTU is set on it. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M_ 1-1 -0 %Y 2 Project No. Date Application Accepted: 1 . (g 1/ Date Application Expires: U (HI (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE .LOCATION Site Address: 'bete 5:itt r/CC J7tZ PKWY Tenant Name: ^,..,I14e. MENU Ls( "2.S King Co Assessor's Tax No.: Z.230g9 ZR Floor: Suite Number: PROPERTY OWNER Name: �Agg..wQ-f Sri) UAg.JG L.L.C. Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Company Name gef.iziCa,6. n ■,� Wv Address: Po. (.li! y 2q 116 Name:. t��se. si t''IEtl Phone: 2 ,� .300' 150) Fax: _ `�`"`''II 86 C( oi, Tukwila Business License No.: sus _63-7L Address: P 0. sox 2 1 L6 State: City: Uelf_ m 1+41,1 � Zip:902 h� Phone: J13.. J Fax:360 it 3_ Ib Email.10erni.i ri1 New Tenant: ❑ Yes No MECHANICAL CONTRACTOR .INFORMATION Company Name gef.iziCa,6. n ■,� Wv Address: Po. (.li! y 2q 116 City: Damm6 NRM State: IA IA. zip$32 Phone: 2 ,� .300' 150) Fax: _ `�`"`''II 86 Contr Reg No.:NQQni Q= $18cticp Date: 211,• it, Tukwila Business License No.: sus _63-7L •wM Valuation of project (contractor's bid price): $ Describe the scope of work in detail: gEtAov 4u. or 3 Cr A s / eLL-cc-•'r" RDOF TDP L11414-5 A -.t p - a -i LACE th M}5 op sprmsS I2E.`(4 p4Sr-171) w 1 Gum SOD Use: Fuel Type: Residential: Commercial: New New Electric ,f Gas Replacement Replacement Other: H:1Applications\Forms-Applications On Line\2016 Applications\ Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial -60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial -60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytim A few sounds are exempt from the noise code, including: Waming devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the pemit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR Signature: HORIZED AGENT: Print Name: Mailing Address: P- 0 •43D.X. 1 Ib Date: 12 - d7' Z617 nI) Day Telephone �7� — tEw k1 City H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh u, 9Zz State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $344.08 M17-0192 Address: 16840 SOUTHCENTER PKWY •Apn: 2623049129 $344.08 MECHANICAL $330.85 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $231.53 PLAN CHECK FEE R000.322.102.00.00 0.00 $66.17 TECHNOLOGY FEE $13.23 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12981 R000.322.900.04.00 0.00 , • $13.23 $344.08 Date Paid: Friday, December 08, 2017 Paid By: NORTHSOUND REFRIGERATION INC Pay Method: CHECK 19671 Printed: Friday, December 08, 2017 9:07 AM 1 of 1 CR(SYSTEMS i ---REVISIONS No changes shall he made to the scope of work r ritho ii prior approval of I Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY PermIt No. M (1-- 0 (9X Plan rev e.w t °cal is subject to errors and omissions. Approval of ccnsfruction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Co, d conditions is acknowledged: B Date: City of Tukwila BUILDING DIVISION 'SEPARATE PERMIT 1::::CILJIF D FOR: 1Mechanical I tectrical L lI mbing IIW&s Piping ICity of Tukwila SI-.D(NG DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 17 2010 WO I city of Tukwila BUILDING DIVISION VL1i 92 WIINF General Data Table 10. General da — 6 to 7.5 to — high efficiency C01RECTION LTR#� M1.7%- 0192, CWILA 018 Putu°' IVTER Single Compressor T/YHC072E/F3,4,W 6 Tons Dual Compressor T/YHC074F3,4 7.5 Tons T/YHC092F3,4, .Cooling Performance(!) Gross Cooling Capacity 72,000 73,000 EER(b) 12.6 13.1 Nominal cfm/AHRI Rated cin 2,400/2,100 2,400/2,100 .. , AHRI Net Cooling Capacity 68,000 71,000 89,000 IEER(c) 14.5 15.5(d) 14,5(e) System Power (kW) 5.37 5.42 7.06 Compressor 4 - s * r.,, ', w" , Number/Type 1/Scroll 2/Scroll 2/Scroll Sound r , 1 _ " • • _ Outdoor Sound Rating (dB)\11 89 89 88 Type Microchannel Microchannel Microchannel Configuration Full Face Face -Split Face -Split Tube Size (in.) 0.71 1 1 Face Area (sq. ft.) 20.77 20.77 20.77 Rows/FPI (Fins per inch) 1/23 1/20 1/20 Indoor Coif .. 49 ... Type Lanced Lanced Lanced Configuration Full Face Intertwined Intertwined Tube Size (in.) 0.3125 0.3125 0.3125 Face Area (sq. ft.) 12.36 12.36 12.36 Rows/FPI(Fins per inch) 4/16 4/16 4/16 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve Drain Connection No./Size in.) 13 NPT 13A NPT 13/4 NPT Outdoor Pari : — ;. i - = 4...:•:.%'''' ° Type Propeller Propeller Propeller No. Used/Diameter (in.) 1/26 1/26 1/26 Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 CFM 5900 5750 6800 Motor HP 0.7 0.7 0.75 Motor RPM 1100 1100 1100 1 Type FC Centrifugal BC Plenum BC Plenum No. Used/Diameter(in.)/W dth (In.) 1/15x15 1/21.0315x6.14 1/21.0315x6.14 Drive Type/No. Speeds(g)/R?M Belt/Variable/1,750 DirectNariable Direct/VaHable Motor HP (Standard/Oversi ,ed) 1.0/2.0 - 2.75/— - 2.75/— Motor Frame Size (Standard/Oversized) (Standard/Oversized) 56/56 —/— ®�`/f`p�r� �/�a E FOR h '["',; •v: _{• () 4 A z a , . - « , � ,F i � is ii+ .i f•I: 44 4, e�::• J 5 * Type Furnished Throwaway Pp,, kiVUlarl LU'1IV�fr:. a _ Throwaway Throwaway Number Size Recommended (4) 20x25x2 �f 1 tl E b (4) 20x25x2 Option f'�Iot Gas ReheateCail r , , - t' • : i y Tube Size (in.) OD - �-'-s--it, 7 i JAN -1 Gui8 rl _• 3. 0.3125 Face Area (sq. ft.) — — 8.652 Rows/FPI(Fins per inch) —• — 1/16 RefrigeraitChar P).'r r ,• p t , --w _ 7.7 vir g 1 avv c. ECMStandard Optional Hot Gas Reheat Cd — .l �V i LD1i G DI:ViS ,tC.4 i d . OF TU Heating Pestonnance"jGss/ EfeCtric OnCy}14, S ♦ .a r.j, . , Heating input _t t -,;a = C01RECTION LTR#� M1.7%- 0192, CWILA 018 Putu°' IVTER t -a1,ct2_ "RANF General Data Table 11. General d — 8.5 to 10 tons — high efficiency CORRE TION LTR# FOR IANCE ED 018 �CEIVED )F TUKWILA N 12 2018 IIT CENTER RT-PRCO23AN-EN 8.5 Tons 10 Tons T/YMC102F3,4,W T/YHC120F3,4,W COolino Periotrhance(a) : • Gross Cooling Capacity 104,000 . e i • EER(b) i = 12.5 Y=12.4 • Nominal cfm/AHRI Rated cPn 3,400/2,720 .: ,: e 0 AHRI Net Cooling Capacity 99,000 113,000 IEER(c) T= 14.7(4) YHC102FW=14.5 AER = 14.1 SZVAV, JEER = 15.2 System Power (kW) 7.92 9.11 Compressor ° :} ''; ,. Number/Type 2/Scroll 2/Scroll Sound . 7 f. Outdoor Sound Rating (dB) el 89 87 Outdoor Coil Type Microchannel Microchannel Configuration Face Split Face Split Tube Size (in.) 1 1 Face Area (sq. ft.) 20.77 26.77 Rows/FPI (Fins per inch) 1/20 1/23 iiidoar-Coit, -� ' . _ a-' Type • Lanced Lanced Configuration Intertwined Intertwined Tube Size (in.) 0.3125 0.3125 Face Area (sq. ft.) 12.36 16.65 Rows/FPI (Fins per inch) 5/16 4/16 Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Drain Connection No./Size in.) 13,4 NPT 13,4 NPT Os•tdoorFan, R -e - 7 - .,. . Type Propeller Propeller No. Used/Diameter (in.) 1/26 1/30 Drive Type/No. Speeds Direct/1 Direct/1 CFM 6,800 7,540 , Motor HP 0.75 0.75 Motor RPM 1,100 ,i00RFVIF%jvFn door Fare ; } Ihtr _, ,. (r s,... C Type (Standard) BC Plenum B 'P n n G~� `"` No. Used/Diameter (in. )/Wkth (in.) 1/21.0315x6.14 1/21.Ip315x6.1APPRCV Drive Type/No. Speeds/RPh to Direct/Variable Direiariabier a Motor HP 2.75/— (q� _ 2.75/— JAN 1 Motor Frame Size —/— Filters(a) r :1 « r _ a . Type Furnished Throwaway Th wawa�3.. Number Size Recommendei (4) 20x25x2 (4) Ox2Sx10"4r �� i fY (2) RPM nl nic; nil conal Hot 6as Reh(eatiCot1- g .. � *- . � ,-�� " -=•"•in Tube Size (In.) OD 0.3125 0.3125 Face Area (sq. ft.) 8.652 15.23 Rows/FPI (Fins per Inch) 1/16 1/16 TV Refngerant-Charge(ibs 3rR-. - 410A)(h1• - r . , f t ,.. , t a q GI rf -Io ; } c- >:. Standard 6.3/4.9 7.7/5.2 Optional Hot Gas Reheat Ca I 6.6/4.7 8.6/5.2 JA Heating'Perrormance (G is/ tlectric onti)r), . .. ;. ; - t' . t CORRE TION LTR# FOR IANCE ED 018 �CEIVED )F TUKWILA N 12 2018 IIT CENTER RT-PRCO23AN-EN AAar S.Paier 1d. Jared #415 Replacement Product Data - 3-10 Ton R410A PKGD Unitary Gas/Electric All Units DX cooling, gas heat —.High efficiency Convertible configuration 10 Ton Major design sequence 208-230/60/3 Microprocessor controls 3ph Medium gas heat 3ph Economizer Dry Bulb 0-100% Standard condenser coil w/hail guard Through the base electrical 3ph Circuit breaker Unpowered convenience outlet (3ph units) tsp.Return air smoke detector 3ph Power exhaust (Fld) CO2 wall mounted, field sensor kit (Fld) Year 6-10 heat exchanger warranty June 26, 2017 Rooftop REVIEWED FOR ODE COMPLIANCE APPROVED JAN 17 2018 City of Tukwila > t Ill nINt � 4 °4h`I RECEIVED CITY OF TUKWILA DEC 0°8 2017 PERMIT CENTER 0161(1 FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 4 of 18 Others Jared #415 Replacement Mechanical Specifications - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al - A3 Qty: 3 Tag(s): R-1, R-2, R-3 June 26, 2017 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R -410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather -resistant baked enamel finish. Units surface shall be tested 672 hours in a salt spray test in compliance with ASTM 8117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil -faced, fire -retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil -faced, closed -cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double -hemmed and gasket -sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2 -inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct -drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3 -stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC (036, 048, 060, 072, 090, 102, 120); standard on YHC (036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward -curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 81/2 ton units (standard efficiency) shall have belt drive motors with an adjustable idler -arm assembly for quick -adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 71 to 81 (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct -drive, statically and dynamically balanced, draw -through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 5 of 18 Others Jared #415 Replacement June 26, 2017 for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube -to -fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all -aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual -sloped, removable and reversible condensate drain pan with through -the -base condensate drain is standard. Tool -less Hail Guards Tool -less, hail protection quality coil guards are available for condenser coil protection. Controls Unit shall be completely factory -wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti -short cycle timing and time delay between compressors to provide a higher level of machine protection. 24 -volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory -installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field -installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Powered or Unpowered Convenience Outlet This is a GFCI, 120v/15amp, 2 plug, convenience outlet, either powered or unpowered. When the convenience outlet is powered, a service receptacle disconnect will be available. The convenience outlet is powered from the line side of the disconnect or circuit breaker, and therefore will not be affected by the position of the disconnect or circuit breaker. This option can only be ordered when the Through the Base Electrical with either the Disconnect Switch or Circuit Breaker option is ordered. Plenum Fan The following unit shall be equipped with a direct drive plenum fan design (all 10 tons and 7.5-8.5 ton high efficiency units). Plenum fan design shall include a backward -curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 6 of 18 Others Jared #415 Replacement June 26, 2017 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Through the Base Electrical Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections inside the curb and through the base of the unit. Option will allow for field installation of liquid -tight conduit and an external field -installed disconnect switch. Through the Base Electrical with Circuit Breaker This option is a thermal magnetic, molded case, HACR Circuit Breaker with provisions for through the base electrical connections. The circuit breaker will be installed in a water tight enclosure in the unit with access through a swinging door. Wiring will be provided from the switch to the unit high voltage terminal block. The circuit breaker will provide overcurrent protection, be sized per NEC and UL guidelines, and be agency recognized by UL/CSA. Supply and/or Return Air Smoke Detector Smoke detector shall be factory installed photoelectric smoke detector mounted in the return air section (with or without the economizer or motorized damper option), AND/OR in the supply air fan compartment. The detector will be wired for continuous power whenever the unit is energized. Upon detection of smoke, the detector will shut down all unit operations. Local codes may dictate the location of detectors. Note: Due to the shipping position of the economizer or motorized damper, the return air smoke detector will not be completely factory installed. The wiring harness for the detector will be routed and tied off in the fan compartment for shipping. The smoke detector and barometric damper hood will also be installed in a shipping position in the fan compartment. Accessory - Powered Exhaust The powered exhaust shall provide exhaust of return air, when using an economizer, to maintain better building pressurization. Accessory - CO2 Sensing The CO2 sensor shall have the ability to monitor space occupancy levels within the building by measuring the parts per million of CO2 (Carbon Dioxide) in the air. As the CO2 levels increase, the outside air damper modulates to meet the CO2 space ventilation requirements. Supply, Return, and Plenum Air Smoke Detector With this option installed, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit. In order for the supply air smoke detector or return air smoke detector to properly sense smoke in the supply air stream or the return air stream, the air velocity entering the smoke detector unit must be between 500 - 4000 feet per minute. Equipment covered in this manual will develop an airflow velocity that falls within these limits over the entire airflow range specified in the evaporator fan performance table. Supply and/or Return Smoke Detectors may not be used with the Plenum Smoke Detector. FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 7 of 18 Others Jared #415 Replacement Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al - A3 Qty: 3 Tag(s): R-1, R-2, R-3 June 26, 2017 3/4"-14 DIA HOLE CONDENSATE DRAIN 27 5/8" 4 3/4" ISOMETRIC -PACKAGED COOLING FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 8 of 18 Others Jared #415 Replacement Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al - A3 Qty: 3 Tag(s): R-1, R-2, R-3 ELECTRICAL / GENERAL DATA June 26, 2017 'GENERAL (2)(4") Model: YHC120F Oversized Motor HEATING PERFORMANCE HEATING - GENERAL DATA Unit Operating Voitage: 187-253 MCA: N/A Heating Model: 'Medium Unit Primary Voltage: Unit Secondary Voltage 208 MFS: N/A Heating Input (BTU): 200,000/140,000 230 MCB: N/A Heating Output (BTU): 160,000/112,000 Unit Hertz:60 Unit Phase: se: 3 No. Burners: 4 No. Stages 2 EER Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: '46.1 MCA: N/A Natural Gas (Min/Max): '4.5/14 MFS: 60.0 MFS: N/A LP (Min/Max) 10.0/14.0 MCB: 60.0 MCB: N/A Gas Pipe Connection Size: 3/4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number: '1 Number: N/A Number: N/A Horsepower: 3.8 Horsepower: N/A Horsepower: N/A Motor Speed (RPM): -- Motor Speed (RPM): N/A Motor Speed (RPM): N/A Phase ' 3 Phase N/A Phase N/A Full Load Amps: 8.5 - 8.5 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: __ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1 /2 OUTDOOR MOTOR Number: '2 Number: '1 Horsepower: 5.1/3.0 Horsepower: 0.75 Phase: 3 Motor Speed (RPM): 1100 Rated Load Amps: 19.6/10.4 Phase: 3 Locked Rotor Amps: 136.0/73.0 Full Load Amps: 2.7 Locked Rotor Amps: 9.8 POWER EXHAUST ACCESSORY 131 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: 1 Type: Throwaway Horsepower: 0.87 Furnished: Yes Factory Charge Motor Speed (RPM): 1075 Number 3 / 2 Circuit 81 7.1 Ib Full Load Amps: 5.7 Recommended 20"x25"x2" Circuit 82 5.0 Ib Locked Rotor Amps: 13.6 20"x30"x2" NOTES: 1. Maximum (HACK) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 10 of 18 Others Jared #415 Replacement Accessory - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al - A3 Qty: 3 Tag(s): R-1, R-2, R-3 June 26, 2017 ECONOMIZER HOOD ECONOMIZER HOOD 16 3/4" ECONOMIZER HOOD ACCESSORY 6 7/8" FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 13 of 18 Others Jared #415 Replacement Accessory - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al - A3 Qty: 3 Tag(s): R-1, R-2, R-3 June 26, 2017 POWER EXHAUST POWER EXHAUST ECONOMIZER HOOD 4 5 5/8" 21 5/8" POWER EXHAUST AND HOOD ACCESSORY FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 14 of 18 Others Jared #415 Replacement Accessory - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al - A3 Qty: 3 Tag(s): R-1, R-2, R-3 F2 7/8" 4 11/16" June 26, 2017 NOTES: 1. SEE ENGINEERING SPECIFICATION FOR DETAILS. 2. VERIFY ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. BAYCO2K001 B - WALL MOUNT CO2 ACCESSORY FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 15 of 18 Others Jared #415 Replacement Field Wiring - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al - A3 Qty: 3 Tag(s): R-1, R-2, R-3 June 26, 2017 / f -77 0 0 I I HTB1 `1t i - ' O V V 0 O . V ZONE SENSOR WIRE TABLE WIRE SIZE MAXIMUM WIRE LENGTH 22 GAUGE 20 GAUGE 18 GAUGE 16 GAUGE 14 GAUGE NOTE: 1. All wiring and devices shown dashed to be supplied and installed by the customer in accordance with national and local electrical codes. 2. Low voltage control wiring must not be run in conduit with power wiring. 1800" 3000" 4500" 7200" 11700" FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 16 of 18 Others Jared #415 Replacement Field Wiring - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al - A3 Qty: 3 Tag(s): R-1, R-2, R-3 3.75 June 26, 2017 CO2 SENSOR WIRING ECA DCV 6P8 2 ALPHA 543012 CABLE LTB 0 100EE (RED) 24VAC 150A(BLK) 151A (BRN) F 0 101YY(BLU) LTB 24VAC CO2 W44 (BLU) CO2- CO2 SENSOR 4V 1._) OUT 24COM GND VENTILATION OVERRIDE WIRING RTOM EXHAUST PURGE PRESSURIZE 5J6 2 3 195A (BLK) 194A (BLK) LTB 0 191A (BLK W42 (RED) OPTIONAL POWER EXHAUST ACCY WIRES W43 (BLU) WNI • 1 R (RED) EXH PUR 0 PRS 0 24VAC WN2 2K (BLU) • O 1 0 LI T1 F L2' I I 01-2 T2 FIRE PANEL REF DESCRIPTION ECA ECONOMIZER ACTUATOR F FAN CONTACTOR LTB LOW VOLT TERM BLOCK RTOM OPTIONS MODULE WNI WIRE NUT WN2 WIRE NUT NOTE: 1. DASHED LINES REPRESENT RECOMMENDED FIELD WIRING. 2. APPLIES TO DUCT MOUNTED SENSOR ONLY. NOTES: 1. PRINT ON STRIP -TAC PLUS WITH BLACK LETTERS 2. REDUCE TRIMMED LABEL TO SIZE INDICATED. 3 50" FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 17 of 18 Others Jared #415 Replacement June 26, 2017 Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item Tag(s) Qty Description Model Number Al R-1 1 3-10 Ton R410A PKGD Unitary Gas/Electric YHC120F3RMA--C 001 A2A000A0000 000000000000 A2 R-2 1 3-10 Ton R410A PKGD Unitary Gas/Electric YHC120F3RMA--C 001 A2A000A0000 000000000000 A3 R-3 1 3-10 Ton R410A PKGD Unitary Gas/Electric YHC120F3RMA--C 001 A2A000A0000 000000000000 Field Installed Option Description Part/Ordering Number CO2 wall mounted, field sensor kit BAYCO2K001 B Power exhaust BAYPWRX026A FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 18 of 18 Others Kingworks CONSULTING ENGINEERS 600 Dupont St * Ste B Bellingham, WA 98225 360-714-8260 www.king-works.com JOB TITLE NRS - Jared's Southcenter Structural Cales and Sketches JOB N0. 17201 SHEET NO. 1 ; CALCULATED BY BBJ DATE 12/6/17 CHECKED BY JRK DATE 17/07/17 Code: Loads: FuLa STRUCTURAL CALCULATIONS FOR Northsound Retridgeration Jared's Southcenter RTU Replacement 16840 Southcenter Parkway Tukwila, WA 2015 International Building Code Existing Roof Dead Live 20 psf 25 psf Applied to PDF REVIEWED FOR CODE COMPLIANCE APPROVED JAN 172013 _BU City of Tukwila Mechanical Units Tag Ex Wt New Wt Change Note RTU 1- 7.5T RTU 2 - 7,5T RTU 3 - 10T 956 lbs 956 lbs 1094 lbs 1395.5 lbs 1395.5 lbs 1395.5 lbs 46% 46% 28% increase is greater than 5%, see attached increase is greater than 5%, see attached increase is greater than 5%, see attached Description: Reviewing replacement of (3) new rooftop mechanical units. Structural calculations include check for the increase in demand on the existing structure and seismic/wind anchorage calculations. Structural Sketches Attached in the Appendix Page Item 1 Calc Cover Sheet 2 Disclaimer and results summary 3 Existing Beam Check 6 Overturning. Criteria 8 Lateral Anchorage 9 Appendix 1: Structural Sketches 13 Appendix 2: As -Built Info Frorn Client RECEIVED CITY OF TUKWILA DEC 0 8 2017 PERMIT CENTER �IU1�Olg2 Kingworks CONSULTING ENGINEERS 600 Dupont St * Ste B Bellingham, WA 98226 360-714-8280 www.king-works.com JOB TITLE NRS - Jared's Southcenter Structural Calculations JOB No. 17201 SHEET NO. 2 CALCULATED BY BBJ DATE 12/6/17 CHECKED BY JRK DATE 12/7/17 Structural Review Disclaimer: All weights, geometry, and existing building information has been provided by Northsound Refridgeration. Kingworks takes no responsibility for any incorrect or inaccurate information provided that would change the results of our calculations. Notify Kingworks immediately if any variations from what has been provided are encountered in the field. Structural Review Findings: The new units do not increase demand on the existing structure by more than 5%. The attached structural sketches in the appendix outline required seismic anchorage and strengthening to the existing trusses(as necessary). Kingworks CONSULTING ENGINEERS 800 Dupont St * Ste B Bellingham, WA 98225 380.714-8260 www.king-works.com JOB TITLE NRS - Jared's Southcenter Structural Calm and Sketches JOB NO. 17201 SHEET NO, 3 CALCULATED BY BBJ DATE 12/8/17 CHECKED BY JRK DATE 17/07/17 Review Existing Member to Verify Increase in Demand is Less than 5% Member: Joists under RTU 1 Span Existing Loading Full Uniform Load Point Loads Pi= Partial Uniform Load w1=_1 From New Proposed Loading Full Uniform Load . Point Loads w 41 t, P1= Loading. Shear, and Moment Diagrams Existing Loading Loading Shear Moment 1 Results Summary Partial Uniform Load w'= e i¢ From 4', % Change w1= a From tI to 5248 lbs 5327 Ibs wi=,ir FromJ Moment 93775 ft -lbs New Loading Existing New % Change Status Shear 5248 lbs 5327 Ibs 1.52% OK Moment 93775 ft -lbs 96201 ft -lbs 2.59% OK Kingworks CONSULTING ENGINEERS 600 Dupont St ` Ste 8 Bellingham, WA 98226 360-714-8260 www.king•works.com JOB TITLE NRS - Jared's Southcenter Structural Caics and Sketches JOB NO. 17201 SHEET NO. 4 CALCULATED BY BBJ DATE 12/6/17 CHECKED BY JRK DATE 17/07/17 Review Existing Member to Verify Increase in Demand is Less than 5% Member: Joists under RTU 2 Span Existing Loading Full Uniform Load Point Loads w= P1= Partial Uniform Load w�= New Proposed Loading Full Uniform Load Point Loads w= P = Loading, Shear: and Moment Diagrams Existing Loading Loading 1 Shear Moment Results Summary Partial Uniform Load w1= >Q From a to w,= e a From 1.60% to 9 w,= . From 2.42% to New Loading _A Existing New % Change Status Shear 5257 lbs 5341 IN 1.60% OK Moment 93439 ft -lbs 95703 ft-tbs 2.42% OK Kingworks CONSULTING ENGINEERS 600 Dupont St * Ste 8 Bellingham, WA 98225 360-714-8260 www,king-works,com Jos TITLE NRS - Jared's Southcenter Structural Calcs and Sketches JOB NO. 17201 SHEET No. 5 CALCULATED BY BBJ DATE 12/6/17 CHECKED BY JRK DATE 17/07/17 Review Existing Member to Verify Increase in Demand is Less than 5% Member: Joists under RTU 3 Span Existing Loading Full Uniform Load Point Loads w Partial Uniform Load From New Proposed Loading Full Uniform Load Point Loads Pi Loading, Shear, and Moment Diagrams Existing Loading Loading Shear Moment Results Summary Partial Uniform Load w1_ Existing ra r From :® Status Shear w1= (a..1 From OK to P eq, From e � to New Loading 1 Existing New % Change Status Shear 5205 Ibs 5241 Ibs 0.69% OK Moment 93239 ft -lbs 94537 ft -lbs 1.39% OK Kingworks CONSULTING ENGINEERS 600 Dupont St *Ste B Bellingham, WA 98225 360-714-8260 www.king-works.com Wind and Seismic Overturning Criteria Seismic (ASCE 7-10 Chapter 13), Site Class = Stn. Ip = a = Rp= Bldg Ht = Unit Ht on Bldg = JOB TrrLE NRS - Jared's Southcenter Structural Cates and Sketches JOB NO. 17201 SHEET NO. 6 CALCULATED BY BBJ DATE 12/6/" CHECKED BY JRK DATE 17/07/11 [Assumed] [USGS Hazard Calculator] [ASCE Section 13.1.3] [ASCE Table 13.6-11 [ASCE Table. 13.6-11 [h] [z] Seismic Design Force(ASCE 13.3) Horizontal 0.4dpFfDSWpl1+2h Fp pmax = 1.6SDS1PWP FPmin = 0`3SDSi;pWP Fp = .48 x Wp <-----controls F,3max = 1.55 x Wp Rpm, .29xWp Design Fptt = .48 x Wp Vertical Fpw,t = +/-0.2SdsWp Design Fp„rt = .19 x Wp Wind Loads (ASCE 7-10 Chapter 29 Building Appurtenances) Wind Speed, V Exposure Cat Ka= Kn = ze = Kz = Horizontal GC, = Horizontal GCr = qh = [ASCE Section 26.7.3] [ASCE Table 28.8.1 ] [ASCE Section 26.8] 7 [ASCE Table 26.9-1] 1200 [ASCE Table 26.9-1] 0.70 [ASCE Table 27.3-1 Footnote Equations] 1.9 [ASCE Section 29.5.1 ] 1.5 [ASCE Section 29.5.1] 18.446 psf [ASCE Eq 29.3.1] Phoriz = 35.048 psf P„et = 27.669 psf Kingworks CONSULTING ENGINEERS 800 Dupont St • Ste 8 Bellingham, WA 98225 360.714-8260 www.king-worka.com JOB TITLE. JOB NO. CALCULATED BY CHECKED BY NAS - Jared's Southcenter Structural Calor and Sketches 17201 SHEET NO. 7 BBJ DATE 12/6117 JRK DATE 17107117. Calculate Unit Overturning and Shear For Wind & Seismic Unit: RTU 1 Weight = Length Width Height = Overturning in Short Direction .13 0 NCV II II w = 676 Ibs 12901bs Width = 5.25 Overturning in Long Direction 676 Ibs = 8131bs Z Length = 8.333 ft Max/Min Reactions (LRFD) 1.2D+E: 1257 Ibs .9D+E: 208 lbs 1.2D+W: 1985 Ibs .9D+W:-519 lbs MaxiMin Reactions (ASD) D+.7E: 992 Ibs .6D+.7E: 125 Ibs D+.6W: 1387 Ibs .6D+.6W: -270 ibs Max/Min Reactions (LRFD) 1.2D+E: 1152 Ibs .9D+E: 314 Ibs 1.2D+W: 1658 Ibs .90+W:-1921bs Max/Min Reactions (ASD) D+.7E: 918 Ibs .6D+.7E: < 199 lbs D+.6W: 1190 Ibs .6D+.6W: -74 Ibs kingworks CONSULTING ENGINEERS PROJECT DESCRIPTION .. .. .. .-....I 1►•? . ENGINEER PROJECT NO. 360.714-8260 www.kIng-worksrcom ' 9 z.Z /401 DATE PAGE AS PIA Pr MECHANICAL UNIT PER PLAN 2"x4"x16 GA PLATE WITH (2)# 12 SCREWS INTO MECH'L UNIT AND (2) #12 SCREWS INTO CURB ADAPTOR. (2) PLATES EACH SIDE OF UNIT CURB ADAPTOR (18 GA MIN) ..: #12 SCREW AT 12* OC FOR PERIMETER OF CURB. (E) CURB VERIFY #12aCREWSAT 12" OC MIN, ADD SCREWS AS REQUIRED TO MEET 12" OC CRITERIA. (E) ROOF SHEATHING (E) JOIST OR BLOCKING • ti (a).#"rz ..:rota "xe ;s( :• 2 Z. 5cZEL.). S 18 1,4 Kingworks CONSULTING ENGINEERS 800 Dupont St • Ste 8 Bellingham, WA 88225 SS0-714.8280 www.ding•woncs.com JOB TITLE NRS - Jared's Southcenter Structural Cellos and Sketches JOB NO. 17201 SHEET NO 9 CALCULATED BY BBJ DATE 12/6/17 CHECKED BY JRK DATE 17/07/17 APPENDIX 1: Structural Sketches FOR Northsound Refridgeration Jared's Southcenter RTU Replacement 18840 Southcenter Parkway Tukwila, WA 0 a VERIFY IN FIELD t 90' - 0" (E) CMU WALLS AT PERIMETER, TYP VERIFY IN FIELD NEW RTU, MAX WT = 1,400 LBS (EXISTING WT = 1094 LBS) NEW RTU, MAX WT = 1,400 LBS: (EXISTING WT = 956 LBS): NEW RTU, MAX WT = 1,400 LB (EXISTING WT = 956 LBS) INDICATES 46" DEEP WOOD :TRUSSES AT 4'-0" OC SPANNING BETWEEN CMU WALLS III Digi - Seal Applied to PDF L RTU PER PLAN (E) WOOD TRUSS PER PLAN 10 SIM VERIFY MIN 2x6 BLOCKING BELOW EXISTING CURB BTWN) JOISTS NOTES: 1. NOTIFY KINGWORKS IF ANY DISCREPANCIES FROM EXISTING FRAMING SHOWN ARE FOUND. EXISTING STRUCTURE SHOWN IS BASED ON INFORMATION PROVIDED BY NSR, KINGWORKS TAKES NO RESPONSIBILITY IF ACTUAL FRAMING VARIES FROM WHAT IS SHOWN. 2. EACH UNIT IS SUPPORTED BY (3) TRUSSES MINIMUM. 3. IF MECHANICAL CURB DOES NOT ALIGN WITH PANEL POINT ON JOIST, PROVIDE TRUSS STRENGTHENING PER SSK-03. k i n gwo rks EXISTING ROOF PLAN NSR -SOUTHCENTER JARED'S CONSULTING ENGINEERS, PLLC 600 DUPONT STREET, SUITE B BELLINGHAM, WARMS 960-7148260 Www.king-works.com ,Project number 17201 SSK_O 1 1 Date 12107/17 Dram by BBJ Checked by JRK Scale As indicated mpyngi Kn 12/7/2017911.02M4 Digit. Seal Applied to PDF L MECHANICAL UNIT PER PLAN 2"x4"x16 GA PLATE WITH (2)# 12 SCREWS INTO MECH'L UNIT AND (2) #12 SCREWS INTO CURB ADAPTOR. (2) PLATES EACH SIDE OF UNIT CURB ADAPTOR (18 GA MIN) #12 SCREW AT 12" OC FOR PERIMETER OF CURB. (E) CURB VERIFY #12x3" SCREWS AT 12" OC MIN, ADD SCREWS AS REQUIRED TO MEET 12" OC CRITERIA. (E) ROOF SHEATHING (E) TOP CHORD OF WOOD TRUSS. BLOCKING BTWN TRUSSES AT SIM 11 k i n g� V V A o r'ks MECHANICAL UNIT ANCHORAGE DETAIL NSR - SOUTHCENTER JARED'S CONSULTING ENGINEERS, PLLC 600 DUPONT STREET, WA SUITE BELLINGHAM, 26 98225 360-714-8260 www.king-works.com Project number 17201 SSK-02 SSK-02 Date - 12/07/17 Drawn by Author Checked by Checker Scale 1 1/2". 1'-0" ® copyright Kingworks Consulting Engineers PLLD 2017 12/7/2017 940:33 AM CURB ADAPTOR CURB ADAPTOR (E) CURB (E) CURB (3) SIMPSON SDS25300 SCREWS EA END INDICATES (E) TRUSS PANEL POINT, TYP 2x8 HF#2 SPANNING FROM TOP TO BOTTOM CHORD AS SHOWN (E) WOOD TRUSS 8" MAX OPTION A Digi Seal Applied to PDF L (8) 10d COMMON NAILS EACH END, SPACE EQUALLY (ACCEPTABLE TO STAGGER) OPTION B NOTE: STRENGTHENING SHOWN IN THIS SKETCH IS NOT REQUIRED WHEN DIMENSION 'X' IS LESS THAN 6" 12 3/4" PLYWOOD STRUCT-I PLAYWOOD SHEATHING ki n gwo rks EXISTING TRUSS STRENGTHENING DETAIL NSR-SOUTHCENTER JARED'S CONSULTING ENGINEERS, PLLC 600 DUPONT STREET, SUITEB BELLI3GNAM, WA 98225225Date 360-714-8260 www.king-works.com Project number 17201 SSK-03 12/07/17 Drawn by Author Checked by Checker Scale 3/4" = 1'-0" e copyright Kingwaks ConsNOng Engineers PLLC: 2017 12R/201784833 AM Kingworks CONSULTING ENGINEERS 800 Dupont StSte B Bellingham, WA 98225 360-714-8280 www.kIng-worb.com JOB TITLE NRS - Jared's Southcenter Structural Caics and Sketches JOB NO. 17201 SHEET NO 13 CALCULATED BY 813.1 DATE 12/6/17 CHECKED BY JRK DATE 17/07/17 APPENDIX 2: As-Builts from NSR FOR Northsound Refridgeration Jared's Southcenter RTU Replacement 16840 Southcenter Parkway Tukwila, WA Dated 11415 Re lacement Unit Dimensions - 3.10 Ton R41OA PKGD Unitary Gas/Electric Rooftop item: Al - A3 Qty: 3 Tag(s): R-1, 11-2, Rya June 26, 2017 GAS CONNECTION (SEE NOTE 2) 4017rDO0ii TOP PANEL DENSER FAN. ' EVAPORATOR SECT O1 ACCESS PANEL— CONDENSATE (SEL'thiE:4) — -CONDENSER COIL C MPE Ssi3R ACC t SS PANEL POWER WIRE {SEE NOTGi 3l PACKAGED GAS f ELECTRICAL THROLIOH THE F.TASE CO NOTES 1, ALTERNATE CONOtNSATE DRAIN c N,INECTION ... 314'.:-14 NPT DIA. HOLE .... . 2,12' NR -r GAS CONNECTION (0 mbh.120 mbt } Ft4' NPT GAS CONNECTION (I5 nb ,, 200m64, 25011b15 3. UNIT POWER WIRE 13/0" DIA. HOLE: 4. TRW -THE .BASE ELECTRICAL AND OAS IS NOT STANDARD ON ALL UN ITS. 5 VERIFY WEIGHT, CONNECTION, ANO AU. DIMENSION :WI . INSTALLER °OCOMENTS BEFORE INSTALLATION .: PLAN VIEW Ut+NT OIMCNS1ON DnAVYINia ?i25IRV . 5b7/8' 16 11116` COb. StR CE CONDENSATE DRAIN PACKAGED GAS I ELECTRICAL DIMENSION DRAWING FLO Furnished by Trane U.S. Inc. l In t> tiled by equipment Sabin! al Ushers Page 9 ai 1 Jared 5415 Re = Iacement Weight, Clearance & Rigging Diagram « 3.10 Ton 1141 PKQA Unitary Gas/Electric Rooftop item: Al • A3 Qty: 3 . Teg(a):.R-1, R-2, R - INSTALLED ACCESSORIES NET EIGHT DATA !MRNOAitXfJ3 MOTs la s OSUTSICfE AIR rii MANUl11'C?UT$ DE Aiti t tA1 BAROiiFi[G RELtEP Dvti1T&tzD MOT.ti. I3ELTO IVE t OT♦ POWER E%HAUS'f THROUGHT THE BASE ELECTRICAL AS:{Ftr g} : 13.t] tE UNIT A 3UWTEO CIRCUIT BREAKER k0PSS3 S:tt Ib. POWEREDCONNVEN117M RINSED DOCRS,tF1OP I HAIL I3UARD' TECTOR, SUPPLY ' netu iN. NOVAR CONTROL STAINLESS STEEL I -EAT EXCHANGER ROC* CDPIR CORNER WEIGHTS I CEfdTEA O :CnAYrtl (EtLENfi#17 SFiWtDTH NOTE All %ado g epproxt ; Wabhte to pPttons thn! tas trot rot refer to Onto liti/ ¢rs 0uide- 3. 7hn sow I wBrpIn rue Feted m ata unit namedat8. . 4: Refer to unit nameplate mrd Instal alkn atOde for weight; beim srlreduSna tramponellon andOf fink • tial S: Tho weight Moan representsthe weal urpt opalciana Weight for ate cced'igutaUon eeacied. Ee1'dnoted at +t• 1C %of did nameplate .wool. , 6. Vealy welpttt, cohne teen. and all denensfon wh initaihr dot -favorite beta) installation:: T., Corner wegnts:aro glen for information Oniy ��. 9. NalSnifpng weight at optiwtal anOaserlae slra4d be added to'untt wetgid Mizen ordering (esttory or held InsttilWd aac04sottea, PACKAGED GAS J ELECTRICAL RIGGING AND CENTER OF GRAVITY FLO = Furnis►ted b Others mite US Inc. It felled by Equipri t'atte i"t a# l8 Jar d 11415 ae • acament ... June 2a 2 Weight, Clearance & Rigging. Diagram 3-10 Ton R410A PKQD.Unitary Gas/Electric Rooftop Item: Al • A3 Qty: 3 Tag(s): R-1, R•2, R-3 . EAWANCE'FROM TOP OF MT CLEARANCE 33 CLEARANCE 413' r> it ~»` k r, t yr RANCE 48 DOWNFLOW CLEARANCE 36` HORIZONTAL CLEARANCE :irk GLEARMICE .36' PACKAGED, GAS /ELECTH c EANGE ' .. i1NITC& (Anima' 633116• PACKAGEP GAS/ELECTRIC L oWNFL OV TYPICAL ito it 00ENING FLn: Furnish c d by .Trane U.S. Inc./1 I by Equipment Subn Others Page 12 of 18 CURD SVTGTTALUT M COI RESERVES HERIGHT TO CHANGE WITHOUT NOTIFICATION> IF CURB 18 NQ£DEO IN A DIFFERENT CONFIGURATION COI.NUST 88 NOTIFIED PRIOR TO PLACING AN ORDER.. .:... : 6/1/2018 City of Tukwila Department of Community Development JESSE SIMENSON PO BOX 29116 BELLINGHAM, WA 98228 RE: Permit No. M17-0192 JARED'S JEWELERS 16840 SOUTHCENTER PKWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/23/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/23/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, h e'�le Permit Technician File No: M17-0192 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development December 20, 2017 JESSE SIMENSON PO BOX 29116 BELLINGHAM, WA 98228 RE: Correction Letter # 1 MECHANICAL Permit Application Number M17-0192 JARED'S JEWELERS - 16840 SOUTHCENTER PKWY Dear JESSE SIMENSON, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Alien Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Provide manufactures specification complete with the EER ratings per WSEC, TABLE's C403. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 If you have any questions, I can be reached at (206)433-7165. Sincerely, Rachelle Ripley Permit Technician File No. M17-0192 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0192 DATE: : 01/12/18 PROJECT NAME: JARED'S JEWELERS SITE ADDRESS: 16840 SOUTHCENTER PKWY Original Plan Submittal Revision # X Response to Correction Letter # 1 Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/16/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ DUE DATE: 02/13/18 (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT CQCRD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0192 DATE: 12/12/17 PROJECT NAME: JAREDoS JEWELERS SITE ADDRESS: 16840 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: COltr. ZN)4 Building Division II Public Works Fire Prevention Structural it* Planning Division n ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/12/17 Structural Review Required REVIEWERc6 INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 01/09/18 ❑ Approved with Conditions ❑ Corrections Required oim 4.1 Denied (corrections entered in Reviews (ie: Zoning Issues) Notation: REVIEWERc$ INITIALS: DATE: [Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: P(1.-- 12/18/2013 City of Tukwila REVISION SUBMITTAL Department of Community Development 6 300 Southcenter Boulevard, Suite #100 T ikwila, Washington 98188 Phone: 206-431-3670 Web site: http://wvTukwilaWA.gov7) Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: -1 1 1'0 1 8 Pian Check/Permit Number: M17-0192 ❑ Response to Inc( mplete Letter # ® Response to Corection Letter # 1 El Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Deferred Submittal # Project Name: JARED'S JEWELERS Project Address: Contact Perso 16840 SOUTHCENTER PKWY Summary of Revision : Phone Number: DO' cft- RECEIVED CITY OE TUKWILA JAN 12 2018 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of nevi: Received at the City o= NORTHSOUND REFRIGERATIO'T INC Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & industries Page 1 of 2 Search L&I A -Z Index Help - My L&1 Workplace Rights Trades & Licensing NORTHSOUND REFRIGERATION INC Owner or tradesperson Principals MILSTEAD, PAUL STUART, PRESIDENT Doing business as NORTHSOUND REFRIGERATION INC WA UBI No. 602 170 260 PO BOX 29116 BELLINGHAM, WA 98228 360-380-1381 WHATCOM County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. NORTHRI898CG Effective — expiration 02/07/2011— 02/07/2019 Bond CBIC Bond account no. SI8582 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 02/07/2011 02/03/2011 Expiration date Until Canceled Insurance Berkley Insurance Co $2,000,000.00 Policy no. CPA602833622 Received by L&I Effective date 06/02/2017 06/09/2017 Expiration date 06/09/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602170260&LIC=NORTHRI898CG&SAW= 1/23/2018