Loading...
HomeMy WebLinkAboutPermit M17-0195 - BOEING #13-03 DCMA - APT RECONFIGURATIONBOEING #13-03 - DCMS APT RECONFIGURATION 10002 E MARGINAL WAY S M17-0195 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0003400021 Permit Number: 10002 E MARGINAL WAY S BLDG 13- Issue Date: 03 Permit Expires On: BOEING #13-03 DCMA - APT RECONFIGURATION M 17-0195 1/11/2018 7/10/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 AMY HIGHTOWER 3051 E VALLEY RD , RENTON, WA, 98057 APOLLO MECHANICAL CONTRACTORS 1133 W COLUMBIA DR, KENNEWICK, WA, 99336 APOLLMC864JQ Phone: (253) 872-5151 Phone: (509) 586-1104 Expiration Date: 4/18/2018 DESCRIPTION OF WORK: DEMO AND REINSTALLATION OF 2 VAVS, 11 GRILLES/DIFFUSERS AND ASSOCIATED DUCTWORK Valuation of Work: $21,570.00 Type of Work: REPLACEMENT Fuel type: Fees Collected: $505.38 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to t e condins ttached to this permit. Signature: Print Name: dToklJ/L Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the 'Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW&. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. MI1 011 Project No. I v Date Application Accepted: ii 1 Date Application Expires: 4 ` U (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION 'QO0 Site Address:1 ,900 E Marginal Way S, Tukwila WA 98108 Suite Number: Floor: Tenant Name:` The Boeing CO t119rO7 New Tenant:. ❑ Yes ®..No King Co Assessor's Tax No.: PROPERTY OWNER Company Name: Apollo Mechanical Name: Amy Hightower City: Renton State: WA Zip:98057 Name: The Boeing CO Contr Reg No.: APOLLMC864JQ Exp Date: 04/18 City: Renton State: WA zip: 98057 Address: PO Box 7827 Email: ahightower@apollosm.com City: Seattle State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Company Name: Apollo Mechanical Name: Amy Hightower City: Renton State: WA Zip:98057 Address: 3051 E Valley Rd Contr Reg No.: APOLLMC864JQ Exp Date: 04/18 City: Renton State: WA zip: 98057 Phone: 253-872-5151 %CKII: 509-727-0438 Email: ahightower@apollosm.com MECHANICAL CONTRACTOR INFORMATION Company Name: Apollo Mechanical Address: 3051 E Valley Rd City: Renton State: WA Zip:98057 Phone: 253-872-5151 Fax: Contr Reg No.: APOLLMC864JQ Exp Date: 04/18 Tukwila Business License No.: BUS -0995010 Valuation of project (contractor's bid price): $ 21,570 Describe the scope of work in detail: Demo and reinstallation of 2 VAVs, 11 Grilles/Diffusers and associated ductwork. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\porms-Applications On Line \2016 Applications\Mechanical Pcrmit Application Revised 1-4-I6.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 11 Floor furnace 1 Suspended/wall/floor mounted heater I Appliance vent Commercial Repair or addition to heat/refrig/cooling system I Air handling unit 2 <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfrn 11 Evaporator cooler 1 Ventilation fan connected to single duct I Ventilation system Commercial Hood and duct I Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 11 Thermostat 1 45 dB(A) I Wood/gas stove Commercial Emergency generator I Other mechanical equipment 65 dB(A) Industrial 60 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/I,750,000 btu 50+hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A HORIZED AGENT: Signature: Date: 12/11/17 Print Name: Amy Hightower 509-727-0438 Day Telephone: Mailing Address: 3051 E Valley Rd Renton WA 98057 City H: Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $505 38 M17-0195 Address: 10002 E MARGINAL WAY S BLDG 13-03 Apn: 0003400021 $505.38 Credit Card Fee $14.72 Credit Card Fee R000.369.908.00.00 0.00 $14.72 MECHANICAL $471.79 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $344.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $94.36 TECHNOLOGY FEE $18.87 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13001 R000.322.900.04.00 0.00 $18.87 $505.38 Date Paid: Monday, December 11, 2017 Paid By: AMY HIGHTOWER Pay Method: CREDIT CARD 009705 Printed: Monday, December 11, 2017 3:18 PM 1 of 1 CirieWSYSTEMS INSPECTION NO. INSPECTION RECORD ��) Retain a copy with permit I PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: _.fiY(- /3-03 Type of Inspection: -L t itC L 01111-L Address: n�� ii ,q /066a- Or M, /y1ti Date Called: Special Instructions: AP r Rff »J! Date Wanted: ' I —,-q- l8 a.m. p.m. Requester Phone No: 2-0(e - 7/3 - to 'b7 pproved per applicable codes. Corrections required prior to approval. COMMENTS: PAd-r-OfAMCIli, FI N� 1 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 11417-0/qg Proect: -t 16- ' 0-6 1�C 3163 Type of Inspection: / ov . rn ft H is Address: HA2 £ 444 7%09414/_. y Date Called: Special Instructions: Date Wanted: a.rn. �. . Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: 61<- Rag0-1X1 itit• ' AW I Cot_ Inspector: Y6 Date:/ - REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Neudorfer Engineers. Consulting Engine-orrs Seattle I'orlland Inc'. Air Handling Unit PROJECT: Boeing Bldg. 13-03 DCMA-APT Reconfiguration LOCATION: SEATTLE, WA PROJECT #: 2018-0084 DATE: 1/29/2018 CONTACT: Andy Eaden AUTHOR: SYSTEM/UNIT: Existing Air Handler AREA: Mechanical Room Log: Tested By: Andy Eaden Date: 1/26/2018 A Existing Air Handler 1/26/2018 Andy Eaden This is an existing air, handler. No unit data was obtained. ,.,, SYSTEM/UNIT: Existing Air Handler/2D6B AREA: 2nd Office Area Unit Data Manufacturer Model Number VAV Address Application # , Cooling Inlet Size Cooling K Factor Enviro-Tec VFREH 1 6606 8 inches 0.60 Nested By: Andy�aden �batte. 1/26/018 141116,_ Air Test Data Existing Air Handler/2D6B Supply Outlet Sum rriarty � \ \•. VAV'F • n DesignSlow VA�V��an ActuallFlow (\Clg'Ma'Des!Primary`ioDy �CIgs,M�Des. Prima Clg Max Act. Fli,mar low \ \pig Min Act.�Pramary Plow 820 CFM 845 CFM 820 CFM 250 CFM 845 CFM 250 CFM N-1 System/Unit Area Served Type of Reading Outlet Type 1 LSize iLLxxWT/ID, '''AK D'esign IcVelocityfl, ; Design+ `Ul h Prelim ,_ Reading Final Reading Final % Remarks Outlet -01 2nd Office Area Flowhood CD44 (10 x.10 ',, 1 " - A -12o5 220 220 107 Outlet -02 2nd Office Area Flowhood j -CD-2 1/410 x 10, >1 dt ;"1-205 215 215 105 Outlet -03 2nd Office Area FIowhood f CD -2w, 10‘x 10 ' 1 C' 205 215 215 105 Outlet -04* 2nd Office Area Flowhbod \CD`2, 10 x 10 1 - 205 195 195 95 (1) Totals: ',Ilk = '7►j 1, - 820 845 .I 845 103 Log: Existing Air Handler/2D6B//Outlet-.044'1/26/20 8 r dytEaden (1 Volume damper is full open. Mr7%- OF/5 RECEIVED CITY OF TUKWILA JAN 292016 PERMIT CENTER Neudorfer Engineers, Inc. Page 1 of 2 Air Handling Unit PROJECT: Boeing Bldg. 13-03 DCMA-APT Reconfiguration LOCATION: SEATTLE, WA PROJECT #: 2018-0084 DATE: 1/29/2018 CONTACT: Andy Eaden AUTHOR: SYSTEM/UNIT: Existing Air Handler/2E5A AREA: 2nd Office Area Unit Data Manufacturer Model Number VAV Address Application # Cooling Inlet Size Cooling K Factor Enviro-Tec VFREH 2 . 6606 10 inches 0.57 Log: Tested By: Andy Eaden Date: 1/26/2018 A Air Test Data VAV Fan Design Flow. VAV Fan Actual Flow Clg Max Des. P n matyFlow CIg Min Des!Pnmary Flow Clg Max Act. Primary Flow CIg Min- Act,Primary Flow \I150 (1) CFM 150 CFM 1150 (1) CFM 420 CFM 1150 CFM 4120f CFM Existing Air Handler/2E5A 1/26/2018 Andy Eaden (1)IWithrthe primary air damper full open, the actual airflow is 1,160 FFM. The original design was 1,400 COW NEI called`�the mechanical engineer and informed him'�bff v tnuch air the box could do with the primatySair�'QJamper full open. The mechanical engineertaTfine with the new design of 1,150 CFM. Existing Air Handler/2E5A Supply Outlet Summary a System/Unit Area Served Type of Reading Outlet Type Size-� LxWf Sl AK, "Designj' [[Veeelocity Desigri Value `+Prelim { SYR ading Final Reading Final % i Remarks Outlet -01 2nd Office Area Flowhood CD -3 10 k 10^ , 1 t / t230" w - 270 235 102 Outlet -02 2nd Office Area Flowhood CD -3 '10 x 10 \1 `, - . t23Q " 250 235 102 Outlet -03 2nd Office Area Flowhood CD -,3,1 ,10 x 10\ 1 \, ' - K jit.230 220 230 100 Outlet -04 2nd Office Area Flowhood\ CD -3 00 x 70 \ 1 f • 4,, j230 220 235 102 Outlet -05* 2nd Office Area Flowhdode ACD -3N 100x 10 /1 N,N ) 230 200 215 93 (1) Totals: 1W., 1M4., - - S " 1150 1160 1150 100 - Log: � r Existing Air Handler/2E5A/Outlet-05 \1/26/2018 AndytEa'd n N (1) Volume damper is full open. v v/41/ o. 4% � MC7 o�9s RECEIVED CITY OF TUKWILA JAN292018 PERMIT CENTER Neudorfer Engineers, inc. Page 2 of 2 C A\ICAL VAC \D GENERAL NOTES: GENERAL SYMBOL DESCRIPTION -IL11 RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN MEE I 24/1, I 24/1"\`� DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST i<l ROUND DUCT, NUMBER INDICATES DIAMETER b 240 m 240 f f DUCT TYPE SMOKE DETECTOR OVAL DUCT, FIRST NUMBER INDICATES MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER b 24/12=- 4 I'f 124't2. f U © SUPPLY AIR DUCT. SQUARE OR RECTANGULAR ELBOW FACING TOWARDS I \/ �\ I �.C— 100 CFM AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING AWAY MESUPPLY SCREENED OPENING AND CFM AIR FLOW ROUND,TE BOWR ACINGST WARDSR DUCT Mr --- __ EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING AWAY 1111010 I 1 T I EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING TOWARDS LINEAR DIFFUSER AND CFM AIR FLOW (SEE NOTE 4) I I EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR. ELBOW FACING AWAY 1111111 F'7 IBJ ti TRANSITION RECTANGULAR TO RECTANGULAR /-*Y_ / RETURN/RELIEF GRILLE, CEILING TYPE, NON -DUCTED CO \ TRANSITION AT TAKE OFF iii 1-10 UNIT HEATER, VERTICAL PROJECTION 6-4TOA. � �I�I UISQUARE OP. RECTANGULAR TO ROUND OR OVAL triUP DUCT OFFSET UP OR DOWN 11 11 DOWN rillOPPOSED BLADE DAMPER rillPARALLEL BLADE DAMPER AD SD VOLUME DAMPER LINED DUCT WITH AXIAL FLOW FAN Fil I \f DUCT DAMPER, MOTOR OPERATED (ELECTRIC OR PNEUMATIC) rrl IA ��u UUU BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) MB-' BDD AD OR AP ACCESS DOOR (AD) OR ACCESS PANEL (AP) IL SFD SMOKE FIRE DAMPER (I HOUR) + i + f ISFD f SFD2 SMOKE FIRE DAMPER (2 HOUR) i 4j l ;SFD2 I f r________ SEPARATE PERMIT 1,,2Q JIRFD FOR. Q Mechanical 0,Clectn'cal (-i mbing itAas Piping .E '1'..1....1.. f vt r uc�VVII DIVISION GENERAL SYMBOL DESCRIPTION -IL11 ,,1 RECTANGULAR DUCT, SQUARE ELBOW WITH TURNING VANES L_��� IL \ N RECTANGULAR DUCT, RADIUS VANED ELBOW 000E EXTRACTION GRID l© P14 ----4H FLEXIBLE DUCT DUCT TYPE SMOKE DETECTOR FLEXIBLE DUCT CONNECTION DUCT TYPE HEAT DETECTOR I'f PRESSURE REGULATOR U © SIDEWALL SUPPLY AIR DIFFUSER, GRILLE OR REGISTER AND CFM AIR FLOW —y ittoo CFM APPKuVto 11 2017 �.C— 100 CFM SIDEWALL RETURN/EXHAUST AIR GRILLE OR REGISTER AND AIR FLOW 100 "*"--VIM lh SCREENED OPENING AND CFM AIR FLOW SUPPLY OUTLET, CEILING TYPE, DIFFUSER OR GRILLE, SQUARE OR RECTANGULAR AND CFM AIR FLOW (4 TYP) El --- __ TEMPERATURE TRANSMITTER SUPPLY OUTLET, CEILING TYPE, ROUND AND CFM AIR FLOW (SEE NOTE 4) I 1 T I LINEAR DIFFUSER AND CFM AIR FLOW (SEE NOTE 4) I I RETURN/EXHAUST REGISTER OR GRILLE, CEILING DUCT TYPE AND CFM AIR FLOW F'7 IBJ ti I /-*Y_ / RETURN/RELIEF GRILLE, CEILING TYPE, NON -DUCTED CO \ UNIT HEATER. HORIZONTAL \O/ i \ UNIT HEATER, VERTICAL PROJECTION LINED DUCT itin SOUND ATTENUATOR f i LINED DUCT WITH ACCESS DOOR AND SMOKE DAMPER AD SD LINED DUCT WITH AXIAL FLOW FAN Fil CENTRIFUGAL FAN CENTRIFUGAL FAN, INLET GUIDE VANES IA ��u UUU EXHAUST FAN SUPPLY AIR FLOW DIRECTION -,V-4... . RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION GENERAL SYMBOL DESCRIPTION APPROVED THERMOSTAT, REMOTE, CEILING Q REVISION Q HUMIDISTAT, WALL 000E HUMIDISTAT CEILING l© KB 4D DUCT TYPE SMOKE DETECTOR PD DUCT TYPE HEAT DETECTOR SRSTATIC PRESSURE REGULATOR U © TEMPERATURE SENSOR, HUMIDITY SENSOR, DUCT MOUNTED MIN APPKuVto 11 2017 0 THERMOSTAT, WALL ON NIGHT THERMOSTAT THERMOSTAT, CEILING El of Tukwila �E� TEMPERATURE TRANSMITTER © 3 . ; VAV BOX LEGEND VV=VARIABLE AIR VOLUME TERMINAL UNIT MARK NUMBER—/ BY APPROVED Mk 0)161 REVISION 80 APPROVED 000E A ISSUE FOR CONSTRUCTION KB c 3.14.90 RE` CODE iEv ED FOR COMPLIANCE_ B 1 APPKuVto 11 2017 1 IAT DEC I City �E I! 111 of Tukwila �E� 3 . ; 808 RE0510N BY APPROVED ' DATE 0)161 REVISION 80 APPROVED 000E A ISSUE FOR CONSTRUCTION KB CL 3.14.90 B 01MA-APT RECONFIGURATION W5319392 FSI 10.25.17 SUGGESTED ABBREVIATIONS ABBREVIATION DESCRIPTION A AAV AD ADD AF AFF AP APPROX ARCH AUT AVG BI BDD BFP BHD BHP BLDG BOD BOP BOS BTU BTUH BW C Cv 'C CAP CC CCW CFM CI CQID CONN CONT CPLG CPVC CW DA DB DBD DIA 0 DIS DIR DN DS DWG dB EA EAT EFF ELL ELEC ELEV, EL ESP EVAP EWT EXH EXIST EXT FC FD FLR FCO FOB FOF FOC FOT FPM FRP FS FT FV GAL CPM GALV GA HC HD HORIZ HP HPC HR HVAC HPU HTG ID IE IGV INSUL IN ANCHOR AUTOMATIC AIR VENT ACCESS DOOR ANGULAR DOWN DISCHARGE AIR FOIL WHEEL ABOVE FINISHED FLOOR ACCESS PANEL APPROXIMATELY ARCHITECTURAL ANGULAR UP DISCHARGE AVERAGE BACKWARD INCLINED WHEEL BACK DRAFT DAMPER BACKFLOW PREVENTER BOTTOM HORIZONTAL DISCHARGE BRAKE HORSE POWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUTTWELD COMMON FLOW COEFFICIENT TEMPERATURE - DEGREES CELSIUS CAPACITY COOLING COIL COUNTER CLOCKWISE ROTATION CUBIC FEET PER MINUTE CAST IRON CENTER LINE CONDENSATE CONNECTION CONTINUED/CONTINUATION COUPLING CHLORINATED POLYVINYL CHLORIDE CLOCKWISE ROTATION DIRECT ACTING DRY BULB TEMPERATURE DOWN BLAST DISCHARGE DIAMETER DEIONIZED WATER SUPPLY DEIONIZED WATER RETURN DOWN DOWNSPOUT DRAWING DECIBELS EXHAUST AIR / EACH ENTER AIR TEMPERATURE ('F) EFFICIENCY ELBOW ELECTRICAL ELEVATION EXTERNAL STATIC PRESSURE EVAPORATOR ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR / EXTERNAL TEMPERATURE - DEGREES FAHRENHEIT FORWARD CURVE WHEEL FIRE DAMPER FLOOR FLOOR CLEAN OUT FLAT ON BOTTOM FACE OF FLANGE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE GLASS FIBER REINFORCED PLASTIC FLOW SWITCH FEET FACE VELOCITY FPM GALLONS GALLONS PER MINUTE GALVANIZED GAGE, GAUGE HEATING COIL HEAD - FEET OF WATER HORIZONTAL HORSEPOWER HIGH PRESSURE CONDENSATE HOUR HEATING, VENTILATING AND AIR CONDITIONING HEAT PUMP UNIT HEATING INSIDE DIAMETER INVERT ELEVATION INLET GUIDE VANE INSULATION INCHES PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED Qi BOE/NG° — ACCEPTABILITY THIS 0E510N AND/OR SPECIFICATION IS APPRO' ED APPROVED 8Y DEPT. DATE SUGGESTED ABBREVIATIONS ABBREVIATION DESCRIPTION KW KVA LAT LBS, '# LWT MA MAX MBH MCC MECH MIN MOV MTD, MIG NC NCC NO NTS NPSH OA OBD OF OS&Y OD OVHD PBD PD/AP PDI POC POS PRESS PRV PS ?SIG PSV PVC RA RECT REF REV RH RM ROT RPM ROD RTN RV SA SCFH SCFM SFD SHC SHF SHT SL SO SOV SP SO SS STL STRUC SW SUCT TDH TEMP TH THC THD THRD TOD TOS TOP TP TS TSP TV TYP UBD VAV VD VP VERT VTA VTR WB WCO WG WHA W/ DRAWN M. CAUNITIS KILOWATT KILOVOLT -AMPERE LEAVING AIR TEMPERATURE CO POUNDS LEAVING WATER TEMPERATURE CO MIXED .AIR MAXIMUM HEAT CAPACITY BTU PER HOUR X 1000 MOTOR CONTROL CENTER MECHANICAL MINIMUM MOTOR OPERATED VALVE MOUNTED, MOUNTING NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN / NUMBER NOT TO SCALE NET POSITIVE SUCTION HEAD REVISIONS No changes shad be made to the scope of �� :ork lIfithau,t prior approval of 't.tkwila Building Division. I NOTE: t;e�visians will require a new plan submittal and may include additional plan review fees. PBFC,LIRF AIR 1. SEE DRAWINGS Mtb AND M1c FOR ADDITIONAL MECHANICAL LEGENDS AND ABBREVIATIONS. 2. SEE CONTROL SCHEMATIC(S) FOR ADDITIONAL ABBREVIATIONS AND SYMBOLS RELATING TO CONTROL SYSTEMS. 3. DIFFUSER SYMBOLS WITHOUT AIR FLOW DIRECTION ARROWS INDICATE AIR FLOW IN ALL DIRECTIONS (TWO DIRECTIONS FOR LINEAR DIFFUSERS). AIR FLOW ARROWS ARE USED TO INDICATE DESIRED AIR FLOW DIRECTIONS IN OTHER CASES. 4. SOME ABBREVIATIONS AND SYMBOLS INCLUDED IN THIS LEGEND MAY NOT BE FOUND ON ANY DRAWINGS. THEY ARE INCLUDED HERE AS PART OF A STANDARD LEGEND AND MAY BE UTILIZED IN THE FUTURE. 5.p//4DESIGNATES EQUIPMENT APPEARING ON MECHANICAL EQUIPMENT SCHEDULES. OUTSIDE OPPOSED BLADE DAMPER OVERFLOW OUTSIDE SCREW AND YOKE OUTSIDE DIAMETER OVERHEAD PARALLEL BLADE DAMPER PRESSURE DROP OR DIFFERENTIAL PLBG. & DRAINAGE INSTITUTE POINT OF CONNECTION POSITION PRESSURE PRSSURE REGULATING VALVE PRESSURE SWITCH PRESSURE - POUNDS PER SQUARE INCH, GAUGE PRESSURE RELIEF (SAFETY) VALVE POLYVINYL CHLORIDE REVERSE ACTING (CONTROLLER) / RETURN AIR RECTANGULAR REFERENCE REVISED RELATIVE HUMIDITY ROOM ROTATION REVOLUTIONS PER MINUTE REQUIRED RETURN ROOF VENT FILE COPY Permsxt No. M 17-o(cc SUPPLY AIR Plan review c;)pi oval is subject to errors and omissions. STANDARD CUBIC FEET/HR STANDARD CUBIC FEET/MIN pprovai of construction documents does not authorize COMBINATION SMOKE & FIRE DAM SENSIBLE HEAT CAPACITY SENSIBLE HEAT FACTOR the violation of any adopted code or ordinance. SHEET SOUND LINE SCREENED OPENING SOLENOID OPERATED STATIC PRESSURE SQUARE STAINLESS STEEL STEEL STRUCTURAL SOCKET WELD SUCTION TOTAL DYNAMIC HEAD (FEET OF WATER) TEMPERATURE TOTAL HEAD (FEET OF WATER) TOTAL HEAT CAPICITY TOP HORIZONTAL DISCHARGE THREADED TOP OF DUCT TOP OF STEEL TOP OF PIPE TOTAL PRESSURE TEMPERATURE SWITCH TOTAL STATIC PRESSURE TURNING VANE TYPICAL VALVE Receipt of approved Field Copy and co ditions i a owledged: By: Date: 1–It-r� UP BLAST DISCHARGE VARIABLE AIR VOLUME VOLUME DAMPER VELOCITY PRESSURE VERTICAL VENT TO ATMOSPHERE VENT THROUGH ROOF WET BULB TEMPERATURE WALL CLEAN OUT WATER GAUGE (INCHES OF WATE WATER HAMMER ARREST WITH DAZE HkLKLD D. KLOTZ ENGINEER D. KLOTZ 1810110 G. SMITH 00480008 - C. LYNCH A00010VE0 K. RAMP.ALDINI 5u801 City of Tukwila BUILDING DIVISION 1 OM HVAC LEGEND AND ABBREVIATIONS DCMA-APT RECONFIGURATION - _BUILDING .13 -03 - MECHANICAL MASTER RECEIVED CITY OF TUKWILA DEC 1 1 2017 PERMIT CENTER ERR ISSUED FOR CONSTRUCTION 10.25.17 ® FSi consulting engineers Seottle, Washington REMS1ON W5319392 BOL Solutons & Service B 001E 10.25.17 COL. DEV. CENTER, VA SHEET M1a JOB N0. COMP NO DWG N0. 3-03-M1a 4) VARIABLE AIR VOLUME TERMINAL UNIT (W) SCHEDULE VARIABLE AIR VOLUME TERMINAL UNIT (W) SCHEDULE AR REHEAT COIL MAX PAR VALVE ONLY INLET REHEAT COIL (4)(5) MARK NUMBER MAX COOLING CFMNCH PRPRWARY ESSURE DROP AT MAXIMUM CFM WG VALVE ONLY RADIATED (1) NC LEVEL INLET SIZE DIA. (INCH) PRIMARY CFM (2)(TOTAL CAPACITY KW) NO OF STEPS FAN HP VOLT PHASE (4)(5) REMARKS MARK NUMBER COOLING CFM PRERIMARY RY DROP AT MAXIMUM CFM INCH WG RADIATED (1) NC LEVEL SIZE DIA. (INCH) PRIMARY CFM (2)(2)mat.KW) CAPACITY NO OF STEPS FAN (6. HP VOLT PHASE REMARKS 262 1440 .15 35 10 435 3.0 2 1/3 480 3 TRANE MODEL 1700 VFED OR APPROVED (6) 3A1 400 .15 21 6 120 3.0 2 1/15 480 3 TRANE MODEL 600 VFED OR APPROVED 284 1440 .15 35 10 435 3.0 2 1/3 480 3 TRANE MODEL 1700 VFED OR APPROVED (6) 361 550 .25 26 6 165 2.0 2 1/8 480 3 TRANE MODEL 600 VFED OR APPROVED 285 780 .10 25 8 235 4.5 3 1/8 480 3 TRANE MODEL 1100 VFED OR APPROVED (6) 3A2 235 .05 <15 6 75 1.0 1 1/15 480 3 TRANE MODEL 600 VFED OR APPROVED 2C2 1300 .12 34 10 390 4.5 3 1/3 480 3 TRANE MODEL 1700 VFED OR APPROVED (6) 3A3 550 .25 26 6 165 2.0 2 1/8 480 3 TRANE MODEL 600 VFED OR APPROVED 2C3 1800 .05 31 12 - - - 1/2 480 3 TRANE MODEL 2400 VFCD OR APPROVED (6) 3A4 800 .10 25 8 240 2.0 2 1/8 480 3 TRANE MODEL 1100 VFED OR APPROVED 2C4A 2400 .09 34 12 - - - 1/2 480 3 TRANE MODEL 2400 VFCD OR APPROVED (6) 3B3 480 .20 23 6 145 1.0 1 1/15 480 3 TRANE MODEL 600 VFED OR APPROVED 2C4B 280 .09 15 6 - - - 1/15 480 3 TRANE MODEL 600 VFCD OR APPROVED (6) 3B4A 800 .10 25 8 - - - 1/8 480 3 TRANE MODEL 1100 VFCD OR APPROVED 2C40 105 .02 <15 6 - - - 1/15 480 3 TRANE MODEL 600 VFCD OR APPROVED (6) 3848 540 .25 26 6 165 1.0 1 1/8 480 3 TRANE MODEL 600 VFED OR APPROVED 2C4D 1335 .15 34 10 - - - 1/3 480 3 TRANE MODEL 1700 VFCD OR APPROVED (6) 385 790 .10 25 8 235 4.5 3 1/8 480 3 TRANE MODEL 1100 VFED OR APPROVED 2C5 385 .15 18 6 - - - - - - TRANE MODEL 600 VCCD OR APPROVED 3C1 550 .25 26 6 165 2.0 2 1/8 480 3 TRANE MODEL 600 VFED OR APPROVED 202 1290 .12 34 10 390 4.5 3 1/3 480 3 TRANE MODEL 1700 VFED OR APPROVED (6) 3C3 420 .15 22 6 - - - 1/15 480 3 TRANE MODEL 600 VFCD OR APPROVED 2D5A 600 .30 29 6 - - - - - - ENVIRO-TEC #SDR UNIT SIZE 8 3C4 540 .25 26 6 165 2.0 2 1/8 480 3 TRANE MODEL 600 VFED OR APPROVED 3C5 385 .15 20 6 - - - - - - TRANE MODEL 600 VCCD OR APPROVED 206A 715 .08 30 - 8 - - - - - - TRANE MODEL 1100 VCCD OR APPROVED 301 310 .09 15 6 100 2.0 2 1/15 480 3 TRANE MODEL 600 VFED OR APPROVED 2D6B 820 0.11 20 8 .250 3.5 3 1/2 480 3 ETI MODEL VFR-EH-ECM 0811E (7) 3D2A 1600 .17 35 10 - - - 1/3 480 3 TRANE MODEL 1700 VFCD OR APPROVED 2E2 1300 .12 34 10 390 4.5 3 1/3 480 3 TRANE MODEL 1700 VFED OR APPROVED (6) 3028 1200 .20 33 10 - - - 1/3 480 3 TRANE MODEL 1700 VFCD OR APPROVED 2E3 530 .22 22 10 - - - 1/8 480 3 TRANE MODEL 600 VFCD OR APPROVED (6) 3D4A 800 .10 25 8 - - - 1/8 480 3 TRANE MODEL 1100 VFCD OR APPROVED 2E5A 1400 0.02 26 10 420 6.5 3 1/2 480 3 ETI MODEL VFR-EH-ECM 1018E (7) 3048 2000 .06 33 12 - - - 1/3 480 3 TRANE MODEL 2400 VFCD OR APPROVED 2E5B .50 .0: 2 8 2.0 1.' 1 1/8 •:0 T• E OD 1 00 ' ED OR APPRSVED (6) 3D5A 730 .08 23 8 - - - - - - TRANE MODEL 1100 VCCD OR APPROVED 2F5 185 .04 <15 6 60 1.0 1 1/15 480 3 TRANE MODEL 600 VFED OR APPROVED (6) 2F6A 170 .04 <15 6 60 1.0 1 1/15 480 3 TRANE MODEL 600 VFED OR APPROVED (6) 3D5C 600 .30 29 6 - - - - - - ENVIRO-TEC #SDR UNIT SIZE 8 2066 550 .25 26 6 165 3.0 2 1/8 480 3 TRANE MODEL 600 VFED OR APPROVED (6) 3E1 350 .10 16 6 105 2.0 2 1/15 480 3 TRANE MODEL 600 VFED OR APPROVED 3E4 315 .10 15 6 - - - 1/15 480 3 TRANE MODEL 600 VFCD OR APPROVED 3E5A 550 .25 26 6 - - - - - - TRANE MODEL 600 VCCD OR APPROVED 3E58 740 .09 23 8 225 3.0 2 1/8 480 3 TRANE MODEL 1100 VFED OR APPROVED 3F1 365 .12 16 6 110 3.0 2 1/15 480 3 TRANE MODEL 600 VFED OR APPROVED 3F2 450 .18 22 6 135 2.0 2 1/15 480 3 TRANE MODEL 600 VFED OR APPROVED 3F3 220 .05 <15 6 70 1.0 1 1/15 480 3 TRANE MODEL 600 VFED OR APPROVED NOTES: MAX RADIATED NC LEVEL ® 2.0"WG INLET. NOTES: (1) MAX RADIATED NC LEVEL © 2.0"WG INLET. (1) (2) PRIMARY AIR HEATING CFM IS 30% OF COOLING CFM, (2) PRIMARY AIR HEATING CFM IS 30% OF COOLING CFM, EXCEPT FOR CONSTANT VOLUME BOXES. EXCEPT FOR CONSTANT VOLUME BOXES. CONSTANT VOLUME OPERATION. (3) CONSTANT VOLUME OPERATION. (4) SET FAN SPEED SO THAT TOTAL HEATING CFM (FAN CFM + PRIMARY AIR) (4) SET FAN SPEED SO THAT TOTAL HEATING CFM (FAN CFM + PRIMARY AIR) IS AS CLOSE TO PEAK COOLING CFM AS POSSIBLE. IS AS CLOSE TO PEAK COOLING CFM AS POSSIBLE. (5) FAN POWERED BOXES ARE PARALLEL TYPE. (5) FAN POWERED BOXES ARE PARALLEL TYPE. (6) FURNISH WITH TRANSFORMER FOR MOTOR VOLTAGE (277V,10) (6) FURNISH WITH TRANSFORMER FOR MOTOR VOLTAGE (2771/10) (7) FURNISH WITH SCR CONTROLLER. REVIE Y �/�YG80D FOR CODE COMPLIANCE APPROVED APPROVED DECv 14 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF T U K W I L A DEC 1 1 2017 PERMIT CENTER ' • FSi consulting engineers PROFESSIONAL STAMP & SIGNATURE Seattle, Washington APPLIES TO WORK WITHIN THE CLOUDED - REVISION AREAS ONLY AS INDICATED Solutions & Service ISSUED FOR CONSTRUCTION 10.25.1 T RR SYM REVISION 95 APPROVED 0910 SYM 901510N 8Y APPROVER DATEDRAWN W. 14+ ACCEPTABILITY R.BROWER DATE SUBTITLE EQUIPMENT SCHEDULES CURRENT REVISION W5319392 SYMBOL E DATE RR 10.25.17 8 A ISSUE FOR CONSTRUCTION - MC DK CL 3.14.96 Ok p 6� "H..' ci �. - 'ky THIS DESIGN AND/OR SPECIFICATION IS APPROVED D.KLOTZ -._..-_.-- SHEET N B DELETED BACKUP WS MC DK CL 8.12.96 ® 2 » ,w 0 viii z f(; APPROVED BY DEPT. DATE iDGINEER D.KLOTZ 7111E DCMA-APT RECONFIGURATION M2e - -C - RESTROOM HEAT IN 13-03------. ------ J792353-00 CH 8.11.99 - - - ejtASTAGFEZArig - y,x �• CHECKED GSMDH - - BUILDING-13-03 - - �Da ND. - ---- _ SNP No.---"-""" D RESTROOM HEAT W 13-03 CH 4.12.00 -_ Fs ' +` cN�� APPROVED C.PR VE z 3 E 4792353-02 DCMA-APT RECONFIGURATION. W5319392 FSi 10.25.17 _ ..` � �-.. _ 4-. _ �. ,- _ .. _ oxer o... APPROVER K.RAMBALDINI 2.12.96 MECHANICAL MASTER. COL. DEV. CENTER, WA DwG NO. 13 03 M2e 325 CFM (TYP 4 /CD \325 CFM 3 (TYP 4 El (TYP) VOLUME DAMPER, TYP 360 CFM CD (TYP 4) 3 001 24918 SECURITY s,GRILLE 2 }� SCREENED OPENING (TYP 6 PL) 24018 S CURITY GRILLE 265 CFM /CD (TYP 2) 50 CD CFM 1 2075 CFM (TYP) 24/14 9'-8" BOTTOM OF DUCT 18/12 odII24/18 34/18 34/22 1 34/26 24/14 10X8 OPENING 12" BELOW TRUE CEILING W 7C4Q 360 CFM CD (TYP 4) \ 3 / O, !L 0x12 ® 600 CEM �/ ACCESS Q (TYP 4) I. SFD DOOR 16. IJ 36/24 A OVE /' CEILING/SFD'2D5Fl %CD 150 CFM 1335 S 1 , _ ,rte...........' -- (TYP 4) Cra . 20 SFD SFD TO W/1F46 SEE SHEET 1M10 1-\650 100 TO W/1B5A SEE SHEET 1M10 .' 125f 1 A2FM ,8/10 r 4111L715 8 CFM/ SEE DETAIL / 2M10 M505 140 14/14 CD 185 2 / CFM 0 SEE DETAIL 3.0 CFM Ulf 2. 3 CFM C 3 / 85CDS M505 /W\ 2F6B CD\550 GEM =fIANGER DEITAI 2M10 M5 250 CFM, CD (TYP 2) T SEE DETAIL (��� \_4_/ 2M10 M505 21018 x.150'1 1 1/4"G UP' 2"G DN TO AH3D7 -- = SECOND FLOOR S BOD @ 10'-0"AFF % REMOVAL AIR MEASURING STATION U 0 AH3E7 SPS M504 FCR MANBARS AMS IN R SER, SEE SHEET M504 UP TO AH3E7 FSi consulting engineers PROFESSIONAL STAMP & SIGNATURE Seattle, Washington APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED Solutions & Service 0 LEGEND: 1. SEE SHEET M1 o, M1 b, AND M1c FOR MECHANICAL LEGENDS AND ABBREVIATIONS. (1 > 35 KW DUCT HEATER FOR 28"0 DUCT. SCR CONTROLS TO USE 4-20 rnA SIGNAL OR 0-10 VOLT SIGNAL, 480V 30. 2 >2 MESH 12 GAUGE (0.105" DIA.) HARDWARE CLOTH OVER END OF DUCT PENETRATION. PROVIDE SLEAVE AS REQUIRED. INSTALL WITH TAMPER—PROOF CONSTRUCTION USING TAMPER—PROOF SCREWS OR RIVETS. ISSUED FOR CONSTRUCTION 10.25.17 GENERAL NOTES: 1. VAV TERMINAL UNIT INSTALLATION, SEE DETAIL ( IM10 M503 2. VAV UNIT ACCESS LABELING, SEE DETAIL (7Thi 1M10jM503 3. LAY—IN DIFFUSER INSTALLATION, SEE DETAIL ( T 1M10 M503 REMOVAL NOTES: REMOVE DUCTS, VAV BOXES, COTNROLS, AND DIFFUSERS IN HATCHED AREA. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 14 2t11 8' City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1.1 2017 PERMIT CENTER 4' 0 4' 8' 16' 1111111..2 STRANKYLKMATINU SCALE: 1/8"=1'-0" SY REVISION A ISSUE FOR CONSTRUCTION DY MC DK APPROVED DATE SYM REVISION BY APPROVED DATE CL 3.14.96 F INSTALL SECURITY RWS RWS 04.27.06 B GENERAL REVISION' ' "• C DK CL 8.12 96- G ADL -2 IN 13-03:2 170567-00 .WONG RWS 03.14.08 C AIL HUMIDITY REQUIREMENTS HHRR911 MECHANICALDESIGN - MAN BARS 10598463 D RESTROOM -HEAT IN 13-03 792353-00 CH 8.18.99 J DCMA-APT RECONFIGURATION W5319392 M.WONG FSi RWS 04.23.10 10.25.17 RESTROOM HEAT IN 13-03 792353-02 CH 4.12.00 DRAWN � `�� ACCEPTABILITY' M. CAUNITIS DATE A- E� w100 THIS DESIGN AND/OR CHECKED SPECIFlCATI0N IS APPROVED. D. KLOT HKER PROVED 9Y DEPT. DATE D. KLOTZ SUBTITLE 2ND FLOOR HVAC PLAN CURRENT REVISION W5319392 SYMDO DATE 10.25.17 CHECKED -. - G. 50718 --- 5550aV00- 0. LYNCH APPRO`VE0 k' PAMRAI DWI 7 17 LE (DISCIPI INF) MASTFR DCMA—APT RECONFIGURATION BUILDING 13-03 COI.. A—F/1-7 DEV. CENTER. WA SHEET• 2M1OR OB MFC -95060 COMP NO. - DWG N0. 13-03-2M108 (n ® © u LEGEND: 1. SEE SHEET M1a, M1b, AND M,c FOR MECHANICAL LEGENDS AND ABBREVIATIONS. 1----% 35 KW DUCT HEATER FOR 28"0 DUCT. SCR CONTROLS TO USE 4-20 mA SIGNAL OR 0-10 VOLT SIGNAL, 480V 30. n> Y" MESH 12 GAUGE (0.105" DIA.) HARDWARE CLOTH OVER END OF DUCT PENETRATION. PROVIDE SLEAVE AS -'1 REQUIRED. INSTALL WITH TAMPER -PROOF CONSTRUCTION _ ms 1---"-= ______ ..__.-.._.....--= 325 CFM, CD /CD215 CFM USING TAMPER -PROOF SCREWS OR RIVETS li (TYP 4 ® i \L. , ("(l"P 6) 7 a CD 325 CFM NW( "P 4) _.:`-'4E1 , i w 0.2,; (TYP) ® 1 VOLUME DAMPER, TYP GENERAL NOTES: 262 "®m 2 18112 E - - ( Lff 1. VAV TERMINAL UNIT INSTALLATION, SEE DETAIL 'mmorratamim r 1M10 M503 -:I 2. VAV UNIT ACCESS LABELING, SEE DETAIL I • " 120 �m % 100 1M10 M503 3. LAY IN DIFFUSER INSTALLATION, SEE DETAI L ,1= 1 M 10 M503 I 360 CFM CD a C' (-1 300 CFM/ CD (TYP 4) j - 1041 o° %% SCREENED OPENING �.: ; (TYP 6 PL) TYP 6 3 l.T.- \\ 24018 SECURITY I�] 24x18 .CURIT( CONSTRUCTION NOTES: , -- GRILLE 265 CFM CD GRILLE 2 r7 (TYP 2) INSTALL VAV BOXES, DUCTWORK, RETURN ' \ C�' - . QT / GRILLS AND DIFFUSERS AS SHOWN. .—.__..-��r.. -- (3 ...._ rte-,. 0. - ------- -�""" .. 1 TON">:FK,<--F=�_.- 11 L'. SMECONTROLS �+ � ���.�" 075 CFM (TYP) `�ilPROVEFIELDINSTALL � {�4/t4 9'-8" BOTTOM ON VAV BOX. OF DUCT Ti "' X24/14 -� a Z 1. Y 1 ,.tT�l; Wr�� 3� SEAL VERTICAL DUCT TO ELIMINATE ALL LEAKS AND INSTALL 2" SOUND INSULATION ON W B4 0' �2,M-.7--;18_II,!_jjl.. � r� i4/18 34/22 ' 1 34/26 E rr-" 1-10X8 OPENING EXTERIOR OF DUCTWORK. ®� I 1 '!, 14 �, 1 112" �. - ,; CD '" ! '> 12" BELOW TRUE `" ' I a W CFM , , o CEIUNc 4 PROVIDE SEIMENS TEMPERATURE SENSOR. 04 14 ■ 1i� ,\ - r -- -; Ir`--__=_:=:== COMPATIABLE WITH SCR CONTROL. ZC4C 105 O SA 445 CFM ® 11 0 CFM' I SEC v DETAIL �„ ��p i 0 6"0 ��J iff& Eli. _ Li 7C4A B0 C W 4` ®i 13 CFM, 4 00 2 O 360 CFM CDa 0 ®� Lr_ ':" .R_f (ttP 4) 3 !' 9C4nn 1� :> MOM I i� _ %'r T L._. -._- -- .._—..-- I �� SFD --==' .,., , 10x12 mi 600 CFM rLD5L 36/24 A10VE-\ 6 0 I ACCESS 4 TYP 4 C ILING /SFD ')DSA /CO 150 CFM 1338 0 TOW 1F46 I_ CLOTH- `$ 4)Ewl�'�IYAI[�ItifH SEE SHEET 1M10 L SFD DOOP. 1 160 A!(TYP o 140 Y, =�=��.�: m'----:1:0- --x---- ► REVIEWED -----ate ; : o, -60 X65 l.... �� :8n N% !■�� Dn< 10„,)0Q, L�, °�° SFD 5 D [ FLANGE _. SID " 60' 1� /�� ` •— ._.... ,_I ®CFM COMPLIANCE , o• S. ` ►�SF� _,_ • 5 SF �i 1 0 �' n 0, . `�fppm �• L...— —.—....._--....—.._„_...._.._.. .___.—....—.j{ - _—...__.._ , c......_..,ala lO : �/ :�' APPROVED Is / , m - 1 II 1250, SC ! ""-� `' _� i TO W/1B5.A T 100 ;, rER _,.- 14/121 CFM 2D5, E5A �,'� i (® RG SE` DETAIL i �1 II SEE SHEET 1M10 i D ® a I I -l. _. 715 .� it 1 I �1 t t ;12 l� 0 B IIIIIIIII1 I�` ; ■ 5• AOI �� �S, M10 M505 ) ` DEC _ © Cf y ® m . I x65 N ..:;.:..:"m„ • �� mei 1 � ,I RG s ©_ M� II1 , T 6o ,) m ® CFM : � 1 P C o ! c 5 O _:. W - ®/8 14014 120 I z .._ ' liar 'II N N► 1- �Ivv RG SEE DETAIL d a • Cf` R(''4 � =�- u 170v 2M10 M505 City o Tukwilaa 391 CFM® % '' TYP 2) �� � ouF4 o�� oc �I �A1 Tr 2 v ,.n. M503- CFM DI`+Jt�a !' -'� -- � .;���—„ . r.._ ;��xr��= -M10 _� �� 8� -� �'' � � . � � BUILDING 16/20 UP/ 11A _, ��..�.II�I'� N 3 85 / _ '� © w /Mcg �! P I r 'Ei $' ■ ( W CFM 3 / 50 ._ 120© 9----1..1'..' ,1 p.._-_,-, _. ER 7 Nit / 'CFM �� �1 mu iiI / CCt 550 _ 81 I_ ` / © CFM A ER7IETATE----------- -- 205 CFM m O �0 �• �I�i i y: I` 2M10 �8 (TYP 4) ©� 1 .; t'7:': I�� 6� �C �A!/ RG SEE DETAIL RECEIVED e /: - ommrkmow —: A wl r _- , �. j ei 2M10 M505 CITY OF TUKWILA I ' ,�— t: I incl J � �- 1,1111111111111 F, TIS - '4� - _ _� -�d�i C -_...__.,-- 1 TO -- 1/4"G UP - 2"0 DN - AH3D7 BOD @ AIR MEASURINGAMS 10'-0"AFF%• STATION Um F R IN R 440 AH3E7 SHEET M504 MANBARS L_- SER. SEE UP T DEC 1 1 2017 AH3E7 PERMIT CENTER SECOND FLOOR PLAN N .._-_._.__._..___ ._. --- SCALE: 1/8"=1'-0" 8' 4' 0 4' 8' 16' • FSi consulting engineers ISSUED FOR CONSTRUCTION I w1 RAU9 -A PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED Seattle, Washington Solutions & Service 10.25.17 1 - SCALE: 1/8"=1'-0" SYM REASON 8Y APPROVED OATS SYM REASON 8Y APPROVED DATE ACCEPTABILITY 11RAWN CKEDIns 0416 BUB117LE 2ND FLOOR HVAC PLAN CURRENT REVISION W5319392 SYMBOL DATE o 10.25.17 A ISSUE FOR CONSTRUCTION MC DK CL 3.14.96 F INSTALL SECURITY RWS - RWS 04.27.06 2���'Hw4+0 k' � At,. THIS DESIGN AND/OR SPECIFICATION 6 APPROVED CHECKED C D. KLOTZ SHEET - \ n B GENERAL REVISION MC DK CL 8.12.96 C AOL -2 IN 13-03.2 170567-00 M.WONG RWS 03.14.08 ® BO�,�� 2� a ,�:. A, O r 0 , , APPROVED BY DEPT. DATE ENCINEEMTITLE D KLDRECRO� DCMA—APT RECONFIGURATION 2 M 1 O ~o .0 AIL HUMIDITY REQUIREMENTS _ HARRAH H MECHANICAL DESIGN -MAN BARS 10598463-- M.WONG - RWS 04.23.10 G. SMITH - _ ,. __ _ -_ 13 03 _- - - •- JOB N0: ..... _.._COMP NO... _ .• z J DCMA-APT RECONFIGURATION W5319392 FSi__, _ - _-F t E ..BUIL--DING r.Pya APPROVED C. LYNCH - . MFC -95060 0 RESTROOM HEAT IN 13-03 792353-00,.._CH _, _,.. 8;18.99 „ .10.25.17 -. �� - - _..,- _ �x�� -_ _.___. _ _ WD ND E RESTROOM HEAT IN 13-03 . 792353-02 CH 4.12.00 NI APPROVED K. RAMBALDINI 12.12.96 (DISCIPLINE) MASTER COL. A -F/1-7 DEV. CENTER, WAD 13-03-2M10 5 4 - 2M260 M509 L'T ' 20-x0 3-69 1" 4• 6-0 8-0 1-6 -12'-5" Air' 8-0 8-0 S-0 8 Q7• /4" ff• -0 1/2" 8-0 ff• 0s 2" mo2" on 1 1/2'. 4-6j 3-6 8-0 �---rnr 124' AFF 3 E.PYBEUHSar.....-........... .1..1.....71=_111.. S-0 80 3-6'" 1" ;'1-0 9-0 /1/4" 1)/2" E. "2,, fe O„ C9• /2" 0• 1 1/2" 0• 1,1/4" es 1. �1. 8-0 8-0 7-6 7I b-0 8�li 6�-r-:-.4"--0"--37-6"-- 2" -b�3-c 2" / I-0 1 1/2" „ 9" 1 1/4" /4" 1 1/2' /4 1" 2M260 M510 2M260 M509 CZ 1 an A.5-0 -4426-511 Aft 1/2" 2M260 6"WET LINE RUN IN UNHEATED WALL CAVITY PER BOEING DIRECTIVE. 1" INSU LATION B7 OTHERS 2M260 M509 SECOND FLOOR PLAN SCALE: 1/8 =1 -0 BEAN PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED ......................... 0 FSi consulting engineers Seattle, Washington Solutions & Service LEGEND: • 0 SPRINKLER HEAD 2 -WAY EARTHQUAKE BRACING 4 -WAY EARTHQUAKE BRACING PIPE HANGER ® SPRINKLER RISER GENERAL NOTES: 1. DEFLECTORS OF UPRIGHT SPRINKLERS TO BE LOCATED 22" BOTTOM OF DECK THIS FLOOR U.N.O. DROPS TO BE 1"x(2-2) 0.9.0. SPRINKLERS TO BE 1"x(0-2 1/2) U.N.O. CONSTRUCTION NOTES: E> RELOCATE SPRINKLER HEADS AS REQUIRED PER NFPA13 FOR LIGHT HAZARD ZONES. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 14 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 1 2017 PERMIT CENTER SPRINKLERS SYM TYPE MFG\MODEL SIZE TEMP FINISH CANOPY 0T1' • SSP GEM MOD A 1/2" 155' CHR CHR REC 163' • CONCEAL GEM F976 1/2" 165' CHR CHR NEC 18 00 SSU GEM MOD A 1/2" 155' BRASS - 6 < HSSW GEM MOD A 1/2" 155' BRASS - 1 • DRY PEND GEM F960 1/2" 200' BRASS m0 SSU GEM MOD A 1/2" 200 BRASS 167 TOTAL THIS SHEET 353 ISSUED FOR CONSTRUCTION 10.25.17 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" SY REVISION APPROVED DATE SY6 REVISION DY APPROVED DATE REDRAWN KB CH 7.15.97 A ADL -62- IN 13.03.2 170567-00 ONG RWS 01.25.08 DCMA-APT RECONFIGURATION 5319392 FSI 10:25.17 przteAvo° ACCEPTABILITY THIS 0E100 AND/OR SPECIFICATION IS APPROVED ` APPROVED Br DEPT: DATE DATE CHECKED SU3TITI.E SECOND FLOOR FIRE PROTECTION PLAN CURRENT REVISION W5319392 S09901 GATE 10.25.17 GINE0N CHECKED..r APPROVED APPROVED TITh MECHANICAL MASTER DCMA-APT RECONFIGURATION BUILDING 13-03. COL. A -F/1-7 DEV. CENTER. WA SHE 2M260 O6, NO 0MP- NO.• • 13-03-2M260 ?ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0195 DATE: 12/12/17 PROJECT NAME: BOEING #13-03 DCMA¥APT RECONFIGURATION SITE ADDRESS: 10002 E MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: I)---14-(7 Building Division Public Works A -M N/A-- a-1 --t7 Fire Prevention Planning Division Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWERc6, INITIALS: DATE: 12/12/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: Approved ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) 01/09/18 Notation: REVIEWERc6 INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 APOLLO MECHANICAL CONTP 11 ()Inc Espanol Contact. Safety & Health Claims & insurance 0 Washington State Department of Labor & ndustries Search L&I A -Z Index help Page 1 of 3 My I.&I Workplace Rights Trades & Licensing APOLLO MECHANICAL CONTRACTORS Owner or tradesperson Principals RATCHFORD, BRUCE W, PRESIDENT HIGHTOWER, BOB, VICE PRESIDENT BRISCOE, DAN, VICE PRESIDENT HAISCH, ANGIE, SECRETARY HAISCH, ANGIE, TREASURER Doing business as APOLLO MECHANICAL CONTRACTORS WA UBI No. 600 443 607 Parent company APOLLO SHEET METAL INC 1133 W. COLUMBIA DRIVE KENNEWICK, WA 99336 509-586-1104 BENTON County Business type Corporation Governing persons BRUCE WAYNE RATCHFORD BOB HIGHTOWER; DAN BRISCOE; ANGIE HAISCH; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. APOLLMC864JQ Effective — expiration 04/18/2014— 04/18/2018 Bond Western Surety Co Bond account no. 58714750 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 04/18/2014 04/08/2014 Expiration date Until Canceled Insurance Cincinnati Ins Co $1,000,000.00 Policy no. EPP0044685 Received by L&I Effective date 09/20/2017 09/30/2013 Expiration date 09/30/2018 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600443607&LIC=APOLLMC864JQ&SAW= 12/15/2017