Loading...
HomeMy WebLinkAboutPermit M17-0197 - ACURA OF SEATTLE - DUCTWORK, GRILLES, REGISTERS, DIFFUSERSACURA OF SEATTLE 301 BAKER BLVD M17-0197 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0223100075 Permit Number: 301 BAKER BLVD Issue Date: Permit Expires On: ACURA OF SEATTLE M 17-0197 1/5/2018 7/4/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: OB FIFE PROPERTY II L L C P 0 BOX 726 , BELLEVUE, WA, 98009 MISTY POMADA 18702 NORTH CREEK PKWY, STE 110 , BOTHELL, WA, 98011 COMFORT SYSTEMS USA (NW) INC 18702 NORTH CREEK PKWY - SUITE 110, BOTHELL, WA, 98011 COMFOSU842LB Phone: (425) 883-9224 Phone: (425) 883-9224 Expiration Date: 6/20/2018 DESCRIPTION OF WORK: MINOR DUCTWORK AND RELOCATIONG SOME GRILLES/REGISTERS & DIFFUSERS Valuation of Work: $16,792.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $436.76 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: cA Date:1 " 5 — 1 v Print Name: .\\, & cbrv,(76,0. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M 11, 010 Project No. 12 JS -11 Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 301 Baker Blvd Tenant Name: Acura Seattle @ Southcenter PROPERTY OWNER Name: Misty Pomada Name: O'Brien Auto Group City: Bothell State: WA Zip: 98011 Address: PO Box 726 Email: misty.pomada@comfortsystemsusa.com City: Bellevue State: WA Zip: 98009 CONTACT PERSON — person receiving all project communication Name: Misty Pomada Address: 18702 North Creek Pkwy, Suite 110 City: Bothell State: WA Zip: 98011 Phone: 425-883-9224 Fax: Email: misty.pomada@comfortsystemsusa.com King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ® ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Comfort Systems Northwest Address: 18702 North Creek Pkwy, Suite 110 City: Bothell State: WA Zip: 98011 Phone: 425-883-9224 Fax: Contr Reg No.: COMFOSU842LB Exp Date: 06/20/18 Tukwila Business License No.: BUS -0992852 Valuation of project (contractor's bid price): $ 16,792.00 Describe the scope of work in detail: Minor ductwork, and relocating some grilles/registers & diffusers. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 17 Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heatlrefrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfin 17 Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 17 Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22, District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTH(ZED AGENT: Signature: (w. rt_ Date: I )3 Print Name: Misty Pomada Day Telephone: 425-883-9224 Mailing Address: 18702 North Creek Pkwy # 110 Bothell WA 98011 City H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1.4-16.docx Revised: January 2016 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY PAID $352.76 M17-0197 Address: 301 BAKER BLVD Apn: 0223100075 $352.76 Credit Card Fee $10.27 Credit Card Fee R000.369.908.00.00 0.00 $10.27 MECHANICAL $326.18 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $293.03 TECHNOLOGY FEE $16.31 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13196 R000.322.900.04.00 0.00 $16.31 $352.76 Date Paid: Friday, January 05, 2018 Paid By: COMFORT SYSTEMS USA (NW) INC Pay Method: CREDIT CARD 045655 Printed: Friday, January 05, 2018 11:44 AM 1 of 1 ClaillIVSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $84.00 M17-0197 Address: 301 BAKER BLVD Apn: 0223100075 $84.00 Credit Card Fee $2.45 Credit Card Fee R000.369.908.00.00 0.00 $2.45 MECHANICAL $81.55 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R13017 R000.322.102.00.00 0.00 $81.55 $84.00 Date Paid: Wednesday, December 13, 2017 Paid By: COMFORT SYSTEMS USA INC Pay Method: CREDIT CARD 056750 Printed: Wednesday, December 13, 2017 12:13 1 of 1 PM CRSYSTEMS INSPECTION RECORD Retain a copy with permit —0 INSPECTION NO. PERMIT NO. Ofr CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projecct1:� �' p�- �� 0 ecA�(1(, Q Type of inspection: -1444,— l'�X A% W 1 `,— dl d. ress* 50 li e BLVc Date Called: Special Instructions: Date Wanted: a.m% q...//- 2..0)". p.m. Requester: 10 Phone No: za5, 745---/n Approved per applicable codes. O Corrections required prior to approval. COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION M/7-0097 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:Type /let IR4 Df S'EArrL of Inspection: Address: 3)/ 13'41a7? RL.VVD1 Date Called: Special Instructions: Date Wanted:.m. ,2 a1'/ p.m. A00641. -4N %?✓4rOIA OL- Requester: I ICI_ Phone No: 4/ 765- C?iO Approved per applicable codes. Corrections required prior to approval. COMMENTS: Rcv&f -!N Mvlc1}-L Inspector: Date:��,r REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT CO RD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0197 DATE: 12/13/17 PROJECT NAME: ACURA OF SEATTLE SITE ADDRESS: 301 BAKER BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: �-� iftA4 -')24i Building Division Public Works ❑ l`k AM- 12---ti-H7 it Fire Prevention Structural Planning Division n Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 12/14/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/11/18 Approved Corrections Required ❑ Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 COMFORT SYSTEMS USA (NW) INC Home Espanol Contact Safety & Health Washington State Department of )Labor & Industries Claims & Insurance Search L&I A -Z index Iiell,) Workplace Rights COMFORT SYSTEMS USA (NW) INC. Owner or tradesperson Principals PATTERSON, DAVE A, PRESIDENT GEORGE, WILLIAM III, VICE PRESIDENT MCKENNA, TRENT T, VICE PRESIDENT WEISS, JON -PAUL, VICE PRESIDENT ENGSTROM, BRIAN J, TREASURER Doing business as COMFORT SYSTEMS USA (NW) INC WA UBI No. 600 517 946 Parent company COMFORT SYSTEMS USA INC 18702 NORTH CREK PKWY STE 110 BOTHELL, WA 98011 425-883-9224 KING County Business type Corporation Governing persons RODERICK V KIRKWOOD MIKE FRICKBERG; JOAN KIRKWOOD; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. COMFOSU842LB Effective — expiration 06/20/2016— 06/20/2018 Bond Fidelity & Deposit Ins Co of Maryland Bond account no, 08358695 Received by L&I 06/20/2016 Insurance Zurich American Ins Co Policy no. VTC2JC0826 K6148TI L17 Received by L&I 10/23/2017 Active. Meets current requirements. $12,000.00 Effective date 05/01/2016 Expiration date Until Canceled $2,000,000.00 Effective date 11/01/2017 Expiration date 11/01/2018 Page 1 of 2 My I.CI Trades & Licensing bin v(611/ PS' Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600517946&LIC=COMFOSU842LB&SAW= 12/15/2017 -x� I A33HVIATIO\S 0 ABV AD AFF AHU AP APRVD BF BFC BOT CD CFM CIP CLG CONC CONN CW DB DIMS DN DR DWG EA EAT EF EG EQUIP ESP EWT EXH FF FPM FT FUT GAL GALV GD HP HT HVAC. HWR HWRR HWS ID IN IN WG LAT LBS LD LIN FT LWT MAX MBH MD MIN MOCP MUA N/A OBD OD OSA PH PN POC PRESS PSI RA RG RL RPBP RPM RS DIAMETER ABOVE ACCESS DOOR ABOVE FINISHED FLOOR AIR HANDLING UNIT ACCESS PANEL APPROVED BELOW FLOOR BELOW FINISHED CEILING BOTTOM CEILING DIFFUSER CUBIC FEET PER MINUTE CAST IN PLACE CEILING CONCRETE CONNECTION COLD WATER DRY BULB DIMENSIONS DOWN DRAIN DRAWING EAC H ENTERING AIR TEMPERATURE EXHAUST FAN EXHAUST GRILLE EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST FINISHED FLOOR FEET PER MINUTE FOOT OR FEET FUTURE GALLON GALVANIZED GREASE DUCT HORSEPOWER HEIGHT HEATING, VENTILATING AND AIR—CONDITIONING HEATING WATER RETURN HEATING WATER REVERSE RETURN HEATING WATER SUPPLY INSIDE DIAMETER INCHES INCHES WATER GAUGE LEAVING AIR TEMPERATURE POUNDS LINEAR DIFFUSER LINEAR FOOT OR FEET LEAVING WATER TEMPERATURE MAXIMUM 1000 BRITISH THERMAL UNITS PER HOUR MOTORIZED DAMPER MINIMUM MAX OVER CURRENT PROTECTION MAKE UP AIR NOT APPLICABLE OPPOSED BLADE DAMPER OUTSIDE DIAMETER/DIMENSION OUTSIDE AIR PHASE PROJECT NORTH (REFERENCE) POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH RETURN AIR RETURN GRILLER REFRIGERANT LIQUID LINE REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTIONS PER MINUTE REFRIGERANT SUCTION LINE SA SUPPLY AIR SBC SEATTLE BUILDING CODE SCHD SCHEDULE OF EQUIPMENT SEC SFD SG SMC SOG SEATTLE ENERGY CODE SMOKE FIRE DAMPER SIDEWALL GRILLE SEATTLE MECHANICAL CODE SLAB ON GRADE SL SOUND LINED SMACNA SHEET METAL NATIONAL ASSOCIATION SQ FT SQUARE FOOT OR FEET SS STAINLESS STEEL TDH TOTAL DYNAMIC HEAD TG TRANSFER GRILLE TN TRUE NORTH TYP TYPICAL UNO W W/ W/0 WB WG UNLESS NOTED OTHERWISE WATTS OR WIDTH WITH WITHOUT WET BULB WATER GAUGE GE\RAL LEGE\3 EQUIPMENT TAG TYPE EQUIPMENT TAG NUMBER DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN --a SECTION LETTER SHEET NUMBER WHERE SECTION IS SHOWN c=ps REVISION CLOUD AND CHRONOLOGICAL NUMBER DETAIL REFERENCE OUTLINE POINT OF CONNECTION TO EXISTING OR TO OTHERS' WORK 0 KEY NOTE CALLOUT / WORK TO BE REMOVED HVAC -LEGE\� 0 0 0 >< RG — 100 CD — 100 EG — 100 x AIR FLOW DIRECTION 3UILDI\G v ATI O \ PROJECT ADDRESS: ACURA OF SEATTLE AT SOUTHCENTER 301 BAKER BLVD TUKWILA, WA 98188 BUILDING USE: AUTO SHOWROOM, OFFICE, SERVICE PROPERTY OWNER: ARCHITECT: O'BRIEN FIFE PROPERTY II, LLC P.O. BOX 726 BELLEVUE, WA 98009 (877) 562-7436 LANCE MUELLER & ASSOCIATES SANDY CONDIOTTY 130 LAKESIDE, SUITE 250 SEATTLE, WA 98122 (206) 325-2553 SANDYC@LMUELLER.COM TAX PARCEL: 0223100075 ZONING: CITY OF TUKWILA, LATEST EDITION (TUK—RC) CONSTRUCTION TYPE: III—B, FULLY SPRINKLERED OCCUPANCY TYPE: S-1 WITH B NON—SEPARATED USE PER IBC 508.3 FIN FLR ELEV: +00.00' (PROJECT DATUM) SUPPLY OR OSA DUCT SECTION UP, ROUND OR RECTANGULAR CLIMATE ZONE: RETURN, RELIEF OR EXHAUST DUCT SECTION UP, ROUND OR RECTANGULAR SUPPLY OR OSA DUCT SECTION DOWN, ROUND OR RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN, ROUND OR RECTANGULAR RETURN AIR GRILLE, NUMBER INDICATES CFM QUANTITY SUPPLY AIR DIFFUSER, NUMBER INDICATES CFM QUANTITY EXHAUST AIR GRILLE, NUMBER INDICATES CFM QUANTITY SO 100 SCREENED OPENING, NUMBER INDICATES CFM QUANTITY SLSM II EXISTING DUCTWORK. SOUND LINED SHEET METAL FLEXIBLE EQUIPMENT CONNECTION SFD COMBINATION FIRE AND SMOKE DAMPER FD FIRE DAMPER SD SMOKE DAMPER VOLUME DAMPER MOTORIZED DAMPER GAS TURNING VANES ROUND TO ROUND 45° FITTING SQUARE TO SQUARE 45° FITTING SQUARE TO ROUND 45° FITTING 45° FITTING FOR DUCTWORK GAS PIPING CARBON MONOXIDE SENSOR NITROGEN DIOXIDE SENSOR OCCUPANCY SENSOR SWITCH (ON/OFF/TIMER) REMOTE SENSOR SPEED CONTROLLER THERMOSTAT TERMINAL UNIT REQUIRED EQUIPMENT CLEARANCE CODES 4C KING ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES: 1. 2015 I.B.C. WITH WASHINGTON STATE AMENDMENTS WAC 51-50 2. ICC/ANSI A117.1-2009 ACCESSIBILITY STANDARDS • 3. CITY OF TUKWILA ZONING 4. 2015 INTERNATIONAL MECHANICAL CODE & WAC 51-52 5. 2015 INTERNATIONAL FUEL GAS CODE (IMFGC) & WAC 51-52 6. 2015 NATIONAL ELECTRICAL CODE (NEC) 7. 2015 INTERNATIONAL FIRE CODE (IFC) & WAC 51-54 8. 2015 UNIFORM PLUMBING CODE (UPC) & WAC 51-56 & 51 -57 9. 2015 WASHINGTON STATE ENERGY CODE (COMMERCIAL), WAC 51-11C COBE CO v PLIANCE \OTES OUTSIDE VENTILATION AIR PROVIDED BY EXISTING HVAC SYSTEMS. CONTROLS SHALL BE CAPABLE OF PROVIDING 5 DEGREE DEAD BAND AS REQUIRED BY 2015 WSEC SECTION C403.2.4.2. CONTROLS SHALL BE CAPABLE OF PROVIDING SEVEN DAY PROGRAMMABLE TEMPERATURE SETTINGS, AUTOMATIC SETBACK AND SHUTOFF AND OPTIMUM START AS REQUIRED BY 2015 WSEC SECTION C403.2.4.3. 4. IF SHOWN, MOTORIZED AND GRAVITY DAMPERS SHALL BE PROVIDED AS REQUIRED BY 2015 WSEC SECTION C403.2.4.4, INCLUDING MAXIMUM LEAKAGE RATES IN ACCORDANCE WITH 2015 WSEC C402.4.5.2. GRAVITY DAMPERS USED FOR OUTSIDE AIR INTAKE SHALL BE PROTECTED FROM WIND INFLUENCES. DUCT WORK SHALL BE INSULATED AND PROVIDED WITH VAPOR BARRIER AS REQUIRED BY 2015 WSEC SECTION C403.2.7 AND AS FOLLOWS: TYPE LOCATION R—VALUE SUPPLY OR RETURN IN UNCONDITIONED SPACE 6 DUCT WORK SHALL BE SEALED IN ACCORDANCE WITH 2015 WSEC SECTION C403.2.7.3. 7. ALL DUCTWORK SPECIFIED SHALL BE CLASSIFIED AS LOW PRESSURE AND SHALL BE MANUFACTURED AND INSTALLED IN ACCORDANCE WITH 2015 IMC REQUIREMENTS AND CURRENT SMACNA STANDARDS FOR 2" WG, UNLESS HIGHER STATIC PRESSURES ARE INDICATED ON THE DRAWINGS. 8. PROVIDE SEISMIC BRACING AND SUPPORTS IN ACCORDANCE WITH 2015 IBC FOR SEISMIC DESIGN CATEGORY D AND BASED ON AN IMPORTANCE FACTOR OF 1.0 FOR ALL SYSTEMS, EXCEPTING THE GAS PIPING SHALL HAVE AN IMPORTANCE FACTOR OF 1.5. P3JE:T DESCIPTIO\ ACURA OF SEATTLE REMODEL: MINOR HVAC WORK RELATED TO REMODEL OF PORTIONS OF EXISTING SHOWROOM AND OFFICE CEILINGS. RELATED BUILDING PERMIT: MECHANICAL HVAC WORK LIMITED TO CEILING GRILLE AND DIFFUSER RELOCATIONS TO MATCH ARCHITECTURAL REFLECTED CEILING PLAN AS SHOWN. D16-0243 INTERIOR REMODEL OF EXISTING AUTOMOTIVE DEALERSHIP (REF ARCH SHEET TA -1) VECHA\ICAL SCOPE REVISE MECHANICAL CEILING SYSTEMS TO SUPPORT THE REMODEL OF AN EXISTING AUTOMOTIVE DEALERSHIP SHOWROOM AND OFFICE SPACES. MECHANICAL WORK INCLUDES THE FOLLOWING: 1. FIELD WORK TO SUPPORT EXISTING GRILLES, REGISTERS AND DIFFUSERS SO THAT THE EXISTING CEILING SYSTEMS CAN BE DEMOED. DEMO OF CEILING SYSTEM BY OTHERS. LABOR AND MATERIALS TO RELOCATE THE EXISTING GRILLES, REGISTERS AND DIFFUSERS TO LOCATIONS AS SHOWN TO MEET THE NEW ARCHITECTURAL CEILING LAYOUT DESIGN. CLEAN EXISTING GRILLES, REGISTERS AND DIFFUSERS FOR RE—USE. GE\PAL \OTES COORDINATE ALL WORK WITH THE CEILING STRUCTURE AND OTHER TRADES. FIELD VERIFY GRD LOCATIONS, DROPS AND POSITIONS. 3. ALL HVAC EQUIPMENT, DUCTWORK AND APPRURTUNENECS ARE EXISTING. THERE ARE NO MODIFACTIONS OR ADJUSTMENTS TO EQUIPMENT CAPACITIES, WEIGHTS OR LOCATIONS ON THIS PROJECT. EQUIPMENT LOCATIONS, PIPE AND DUCTWORK DIMENSIONS, IF SHOWN ON PLANS AND DETAILS, ARE NOMINAL SIZES. MAX FLEX DUCT LENGTH SHALL BE 8'-0 6. SUPPLY AND RETURN AIR DUCWORK SHALL BE LINED WITH 1" SOUND LINER WITHIN 10' OF EQUIPMENT, WHERE SHOWN (TYPICAL). 7. WHERE REQUIRED, DAMPERS SHALL BE INSTALLED SO AS TO BE ACCESSIBLE FOR TAB, UNLESS NOTED OTHERWISE. SITE CO\DITIO\S DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. ADDITIONALLY, THE INFORMATION CONTAINED HEREIN IS SUBJECT TO HIDDEN OR UNDETECTABLE PRIOR CONSTRUCTION REVISIONS FOR A NUMBER OF REASONS. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. caw aa.» .:..........,.... REVISIONS No changes shall he made to the scope of work withnut prior approval of Bu Iding Division. NMI; ,_; b v;sii�, ys will require a new plan sutmnittai and may im3ude additional plan review fees. 1 SE 7.'1 T E PERMIT FOR: 0 Mechanical .Iectrtcai poisjumbing Irt4as Piping City of Tukwila BUILDING DIVISION VICI\ITY Iv A POJECT- TAX ASSESSOR #: 0223100075 ACURA OF SEATTLE AT SOUTHCENTER LEGAL D ESC I DTI O \ \3TH TAX ASSESSOR NUMBER: 0223100075 ANDOVER INDUSTRIAL PARK #2 POR . N OF LN PLW & 459 FT S OF S MGN OF BAKER BLVD LESS ST. DAW \G I\DEX SHEET # 4. iiiii Alliglibhk,;, Nierri--------iffis- m ookkv0000, 4014, i M1-1 SITE PLAN - MECHANICAL M2-1 FIRST FLOOR CEILING PLAN — MECHANICAL 1 I - - SOUTHCENTER MALL BAKER BLVD. V.1: STRANDER BLVD . a g "44 JRLINGTON NORTHE a � MINKER BL�� UPLAND DR . - • MIDLAND DR S 178TH ST TRILAND DR s 180TH ST . NOT TO SCALE POJECT- TAX ASSESSOR #: 0223100075 ACURA OF SEATTLE AT SOUTHCENTER LEGAL D ESC I DTI O \ \3TH TAX ASSESSOR NUMBER: 0223100075 ANDOVER INDUSTRIAL PARK #2 POR . N OF LN PLW & 459 FT S OF S MGN OF BAKER BLVD LESS ST. DAW \G I\DEX SHEET # SHEET TITLE MO -0 COVER SHEET — MECHANICAL M1-1 SITE PLAN - MECHANICAL M2-1 FIRST FLOOR CEILING PLAN — MECHANICAL EXPIRED — FILE SSUED FOR PERMIT — Permit No. 1 q Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Data: 1c� City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 14 2011 City of Tukwila BU1LDI11 RECEIVED CITY OF TUKWILA DEC 13 2017 PERMIT CENTER Mi1Ol'P7 TYP PROJECT SCALES: 1/8" & 1/32" PER FT UNO 8' SCALE: 1/8" = 1'-0" 16' COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS A COPYRIGHTED WORK OWNED BY COMFORT SYSTEMS USA (NORTHWEST); INC. ("COMFORT SYSTEMS NORTHWEST") AND COMFORT SYSTEMS NORTHWEST HEREBY RESERVES ITS RIGHT TO PREVENT UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS LAYOUT/DESIGN AND TO OBTAIN DAMAGES THEREFORE. um ines isto Lari wsin oc la LAI CO igg 301 BAKER BOULEVARD TUKWILLA, WASHINGTON 98188 w 1- LL z N 0 00 z 0 0 z 5 0 0 M CD 1- w w z W 0 0 0 m w it 0 z w 0 0 REVISIONS 0. FOR PERMIT 11-30-2016 1. FOR PERMIT 12-13-2017 2. - 3. - DESIGNED SAL CHECKED ASA DATE 11-29-2016 JOB NUMBER 116036 SHEET TITLE COVER SHEET MECHANICAL SHEET NUMBER MO -0 SHEET 1 OF 3 PROP. LINE (FOR REFERNCE) SEPARATE FRANCHISE (NOT A PART OF THIS WORK) PROP. LINE (FOR REFERNCE) PROP. LINE (FOR REFERNCE) 15'-0" DISTANCE TO PROPERTY LINE FROM EXTERIOR WALL EXISTING AREA SEPARATION WALL f EXISTING ACURA DEALERSHIP 3A )SCALE: 1/32" --• 1' — 0" <H BLVD. -1° 0 U AlliSEMEGGINGIONISINIP IMO \\ PROP. LINE (FOR REFERNCE) SHADING INDICATES AREA OF INTERIOR CEILING WORK SITE PLA\ VECHA \ICAL GE\PAL \CIES 1. SHADED AREA ON SITE PLAN INDICATES AREA OF INTERIOR WORK. DLA\ \OTES 0 NOTE NOT USED. EXPIRED RE -ISSUED FOR PERMIT ---> masammam REVIEWED FOR CODE COMPLIANCE APPROVED DEC 14 2017 City of Tukwila BUILDING DIVISION CITYRECFETILIKEDWILA DEC 1 3 2017 PERMIT CENTER 0 16' 32' ALE: " = ' 64' COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS A COPYRIGHTED WORK OWNED BY COMFORT SYSTEMS USA (NORTHWEST), INC. ("COMFORT SYSTEMS NORTHWEST") AND COMFORT SYSTEMS NORTHWEST HEREBY RESERVES ITS RIGHT TO PREVENT UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS LAYOUT/DESIGN AND TO OBTAIN DAMAGES THEREFORE. 00 00 00 ce WI- -10 cs = 0 y m < g ;Si 4 Northwest .4* CsJ 03 CO LC) CNI •cr WA LICENSE: MERITM163CM WV'VW.COMFORTSYSTEMSUSANORTHWEST.COM REVISIONS 0. FOR PERMIT 1. FOR PERMIT 2. - 3. - 11-30-2016 12-13-2017 DESIGNED SAL CHECKED ASA DATE 11-29-2016 JOB NUMBER 116036 SHEET TITLE SITE PLAN MECHANICAL SHEET NUMBER M11 C11 C� o. QUN 121 x (Ecl 0 0 RETAIL PARS 1.9 VENDING 1,20 (R x x x (E) (R) 0_ SERVI•E AN CAS......lE 12 (R) m x (E (R) x 1p SALE SALES 10 El GEN MGR 105 0 O O [F;il 0 0 0 0 0 O C 'Id LI\G PLA\ SCALE: 1/8" = 1' — 0" GE\ PAL \OTES SHADED AREA ON SITE PLAN INDICATES SCOPE OF INTERIOR WORK (SEE M1-1). (E) = EXISTING CEILING GRILLE. (R) = RELOCATED CEILING GRILLE. PLA\ \OTES O NOTE NOT USED. ENTRY 10 10.9 �1 I 12.6) ECHA\ EXPIRED RE -ISSUED FOR PERMIT ---> REVIEWED FOR CODE COMPLIANCE APPROVED DEC 14 2017 City of Tukwila BUILDING DIVISION CAL. RECEIVED CITY OF TUKWILA DEC 13 2017 PERMIT CENTER LE: 1I = 1'- 16' COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS A COPYRIGHTED WORK OWNED BY COMFORT SYSTEMS USA (NORTHWEST), INC. ("COMFORT SYSTEMS NORTHWEST") AND COMFORT SYSTEMS NORTHWEST. HEREBY RESERVES ITS RIGHT TO PREVENT UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS LAYOUT/DESIGN AND TO OBTAIN DAMAGES THEREFORE. 0 ratin UA gisa Cn w m o 0 . w 0) r M LI i'CI) Cf) ce ¢h CO o CO W (/) co M co W ¢ co W W v_- w>- W J Et cc ¢ o zm �t 0 00 N. co ,- REVISIONS REVISIONS 0. FOR PERMIT 1. FOR PERMIT 2. 3. - 11-30-2016 12-13-2017 DESIGNED SAL CHECKED ASA DATE 11-29-2016 JOB NUMBER 116036 SHEET TITLE FIRST FLOOR MECHANICAL SHEET NUMBER M2-1 SHEET 3 OF 3