Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M17-0198 - FLOOR & DECOR - AIR HANDLING UNIT, RTU, DIFFUSER ETC
FLOOR & DECOR 17651 SOUTHCENTER PKWY M17-0198 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3523049088 17651 SOUTHCENTER PKWY FLOOR & DECOR Permit Number: M17-0198 Issue Date: 3/5/2018 Permit Expires On: 9/1/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: LEVITZ TUKWILA LLC 180 N STETSON AVE #324-D , CHICAGO, CO, 80601 VANESSA MASELL 355 UNION BLVD - SUITE 301, LAKEWOOD, CO, 80228 DIRECT MECHANICAL CNTRCTRS LLC PO BOX 872472 , VANCOUVER, WA, 98687 DIRECMC913K0 Phone: (720) 445-4387 Phone: (360) 921-2175 Expiration Date: 6/24/2019 DESCRIPTION OF WORK: MECHANICAL WORK FOR NEW TENANT Valuation of Work: $123,480.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $1,766.57 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: kt ckylii(v) I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: f''76t/ t P& v to Date: 3/-Cj 18 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Mh/ Project NoDate Application Accepted: . ln/IX /f Date Application Expires: (f 6 (For office us onl}) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 17601 South Center Parkway Floor & Decor PROPERTY OWNER Name: Vanessa Masell Name: Cathy Green Address: 355 Union Bvd. Address: 180 N. Stetson Suite 3240 City: Lakewood State: co City: Chicago State: IL Zip: 60601 CONTACT PERSON — person receiving all project communication Name: Vanessa Masell Address: Address: 355 Union Bvd. City: Lakewood State: co Zip: 80223 Phone: (720) 445-4387 Fax: Email: vmasell@centerpoint-is.com Phone: (253) 225-4433 King Co Assessor's Tax No.: 352304-9087 Suite Number: Floor: New Tenant: ® Yes 1=1 „No MECHANICAL CONTRACTOR INFORMATION Company Name: Direct Mechanical Address: City: State: Zip: Phone: (253) 225-4433 Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Contra cter_w.ill_provide-r-ernaining:io r—rnation,at_per--mit issuance Valuation of project (contractor's bid price): $ 123,480 Describe the scope of work in detail: Mechanical work for new tenant Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 10 Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cool ing system 47 dB(A) Air handling unit 1 <10,000 cfm 60 dB(A) Unit Type Air handling unit >10,000 cfm Evaporator cooler Qty I Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Residential, Nighttime Diffuser 10 Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) '1 ff U‘ V2 Boiler/Compressor Qty 0-3 hp/100,000 btu Residential, Nighttime 3-15 hp/500,000 btu Industrial 15-30 hp/1,000,000 btu 55 dB(A) 30-50 hp/1,750,000 btu 57 dB(A) 50+ hp/1,750,000 btu Commercial 57 dB(A) 47 dB(A) V\te 2 Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-1OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CE IFY AT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF POJURY r Y THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: John atcher Day Telephone: Lakewood City AUTHORI Mailing Address: 355 Union Blvd. Suite 301. H:\ApplicationsTorms-Applications On Line\2016 Applications \Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Date: kIk \2-\r (720) 445-4387 CO 80228 State Zip Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R13925 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,426.84 M17-0198 Address: 17651 SOUTHCENTER PKWY Apn: 3523049088 $1,426.84 Credit Card Fee $41.56 Credit Card Fee R000.369.908.00.00 0.00 $41.56 MECHANICAL - $1,319.31 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $1,286.16 TECHNOLOGY FEE $65.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13925 R000.322.900.04.00 0.00 $65.97 - $1,426.84 Date Paid: Monday, March 05, 2018 Paid By: MARK PAVLOV Pay Method: CREDIT CARD 08172G Printed: Monday, March 05, 2018 12:16 PM 1 of 1 CSYSIEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY PAID $1,385.12 EL17-1016 Address: 17601 SOUTHCENTER PKWY Apn: 3523049088 $887.47 Credit Card Fee $25.85 Credit Card Fee R000.369.908.00.00 I 0.00 $25.85 ELECTRICAL $861.62 PLAN CHECK FEE R000.345.832.00.00 1 0.00 $861.62 M17-0198 Address: 17601 SOUTHCENTER PKWY Apn: 3523049088 $339.73 Credit Card Fee $9.90 Credit Card Fee 1 R000.369.908.00.00 0.00 I $9.90 MECHANICAL $329.83 PLAN CHECK FEE R000.322.102.00.00 0.00 I $329.83 PG17-0170 Address: 17601 SOUTHCENTER PKWY Apn: 3523049088 $157.92 Credit Card Fee $4.60 Credit Card Fee R000.369.908.00.00 0.00 I $4.60 GAS $60.56 PLAN CHECK FEE R000.322.103.00.00 0.00 $60.56 PLUMBING $92.76 PLAN CHECK FEE R000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R13034 0.00 $92.76 $1,385.12 Date Paid: Friday, December 15, 2017 Paid By: GREG TOLER Pay Method: CREDIT CARD 852868 Printed: Friday, December 15, 2017 10:17 AM 1 of 1 CRWSYS7EMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter BIvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 117-0/9F Prc� t_ _ °libecO,- spectl TypA piofe l wait o JC/11/ /, . Address:01tein ,ta Date Called: Special Instructions:/ Date Wanted: /0 - �i 2 <-1' a.m. p.m. Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: rAb5te___ Inspector:.//f ce,4 Date:/C' 00 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit !`4/70/98 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr t: Or divots,r eco Type of Inspection: Mecham-NIeat fii, L Address: /757Sct 62634 ?C14tY Date Called: Special Instructions: /O g n4 . Date Wanted:7 - ���� a.m. AO• p.m. Requester: ,AA No: 3&O -95V-'57, lr pproved per applicable codes. Corrections required prior to approval. COMMENTS: 9t/- D63 die ,71,1111M ,t,1 11i Smoke bAr..d[ -f AtreeilZ M yea L NA -L 11 Aide -a (6t4Act gerzy+, Inspect&: a Date: 7 Z0.0' REINSPECTION FEE REQUIRED. Prior to next inspection 'fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project. i FLOOr D Ty�p�e of Inspection: Neck EQU I pr E 1' Address: 76 / (& fear' R4.4)i Date Called: Special Instructions: Date Wanted: �%�j / /�� Requester: Phone No: 1.Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: /91P," Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IN417 —Off INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projeecc : 4, Type of lnspectien: Address: /7 /S ?L Date Called: Special Instructions: Date Wanted:a.m: 4 , (- Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: it) /14,� e4c, .Afr Itjel _51-nplep Or fes-- Q4-, 3.) itibeeP EteciriceL 61,4 Inspector: 13:oc:71) Date: / - /5- Zb/l/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: IU R le A—ea( Type of Inspection: c MCC/79MM- ->'S9 «yvvr-r " Address: /7,s/ 5cyin r /kAy Date Called: Special Instructions: Date Wanted: S"-, 918 m p.m. Requester: Phone No: • PlApproved per applicable codes. E Corrections required prior to approval. COMMENTS: — ()CT I rfEcO(A'_ CC/ Inspector: Date: £ /8 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection. cv INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: -fir l ed.0i� Type of Inspection: � .A RCP/ k - Address: 17(S t Soya -in Bivri Date Called: Special Instructions: Date Wanted:cc --tc, R 2O1� a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: C3 1.0 fAtECHIVIOCh 1. R.o1J(H Inspector: Date: II REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. AND BALANCE REPORT I'iJ1'O176 FAN NAMEPLATE MFG: LENNOX MODEL LGH SERIAL NA SIZE 10-15 tons LOCATION Sales floor TAG: RTU -1-12 EQUIPMENT RTU - 1 LGH180H4MS36 RTU -2 LGH180H4MS36 RTU -3 LGH180H4MS36 RTU -4 LGH180H4MS36 RTU -5 LGH180H4MS36 RTU -6 LGH 180H4MS36 RTU -7 LGH180H4MS36 RTU -8 LGH 180H4MS36 RTU - 9 LGH 180H4MS36 RTU - 10 LGH120H4MM3G RTU - 11 LGH120H4MM3G RTU - 12 LGH120H4MM3G REGISTERS AND GRILLES Room Sales Ggaii0 Outlet RTU1 Design 6000 Initial 4800 5780 5780 96.3% Wiles RTU2 5800 4500 5600 5600 96.67o Sales RTU3 6000 5000 5450 5450 90.8% Sales RTU4 6000 4800 5700 5700 95.0% Sales RTU5 6000 4800 6000 6000 100.0% Sales RTU6 6000 4900 5900 5900 98.3% Sales RTU7 6000 5000 5570 5570 92.8% Sales RTU8 6000 5000 5600 5600 93.3% Sales Sales Sales Sales Entrace Womans Mens IT room Cut room Elec room TOTAL RTU9 6000 4800 6100 6100 101.7% RTU10 4000 3400 3800 3800 95.0% RTU11 4000 3500 3980 3980 99.5% RTU12 4000 3500 4020 4020 100.5% D-2 200 170 190 190 95.0% EF -1 275 203 256 257 93.5% EF -1 275 234 240 242 88.0% EF -2 330 320 310 310 93.9% EF -3 150 140 142 142 94.7% EF -4 150 145 144 144 96% 67180 55212 64782 64785 96.4% REMARKS © 2017 NCI, Inc. '. r .. . CB206-08/17 DATE 05/10/18 PROJECT Floor & Decor 1761 Southcenter Parkway, Tukwila, WA SYSTEM Roof top Units / Gas forced air AREA SERVED SALES READINGS BY Sergey Pavlov Cert# 16-164-09 CI 0 M w I=(13 D 3� u • N Q Drn 0• U o N Z Q M w 0 M u7 RTU 1-12 IL - CITY OF TUKWILA OCT 0 9 2019 PERMIT CENTER AIR AND BALANCE REPORT FAN NAMEPLATE MFG: LENNOX MODEL LGHO6H4EU4G SERIAL 5618A06100 SIZE 5.0 TONS LOCATION Offices, Breakroom, Storage, TAG: RTU -13 Equipment RTU - 13 LGHO6H4EU4G REGISTERS AND GRILLES Room 'Training Name Outlet D-1 Design 400 Initial 505 'TarRio.) 415 405 101.3% Corridor 1 D-1 75 110 109 77 102.("% CEM D-1 175 131 166 170 97.1% Cash 'Vault D-2 150 138 145 147 98.0% D-2 150 127 138 140 93.3% Assistant RM D-1 150 121 141 142 94.7% Break RM 'Womans Restroom D-1 350 405 380 388 110.9% D-3 175 153 161 166 94.9% Mens Restroom Sign Corridor 2 Storage RM D-3 175 146 163 162 92.6% D-4 50 90 51 51 102.0% D-1 100 107 100 100 100.0% D-1 100 95 96 95 95.0% #DIV/0! #DIV/0! #DIVIO! #DIVIO! #DIV/0! #DIVIO! TOTAL 2050 2128 2065 2043 99.7% REMARKS © 2017 NCI, Inc. CB206-08/17 DATE 05/10/18 PROJECT Floor & Decor 1761 Southcenter Parkway, Tukwila, WA SYSTEM Roof top Units / Gas forced air AREA SERVED Offices / Restrooms READINGS BY Sergey Pavlov Cert# 16-164-09 J Z 2 w 2 1- w cc CI nz IL > (V ON 07 U0 Z M RTU - 13 AIR BALANC REPORT FAN NAMEPLATE MFG: LENNOX MODEL LGH SERIAL NA SIZE 10-15 tons LOCATION Sales floor TAG.: RTU -1-12 EQUIPMENT RTU - 1 RTU -2 RTU -3 RTU - 4 RTU -5 RTU -6 RTU -7 RTU -8 RTU -9 RTU - 10 RTU - 11 RTU - 12 LGH 180H4MS36 LGH180H4MS36 LGH180H4MS36 LGH180H4MS36 LGH180H4MS36 LGH180H4MS36 LGH180H4MS36 LGH180H4MS36 LGH180H4MS36 LGH120H4MM3G LGH120H4MM3G LGH120H4MM3G REGISTERS AND GRILLES Sales males Room Glima Outlet RTU1 Design CFM 6000 INF 1u CG'�il 4800 `Wig) Ale na G�Gd] 5780 96.3% RTU2 5500 4500 na 5600 96.5% Sales RTU3 6000 5000 na 5450 90.8% Sales RTU4 6000 4800 na 5700 95.0% Sales RTU5 6000 4800 na 6000 100.0% Sales RTU6 6000 4900 na 5900 98.3% Sales RTU7 6000 5000 na 5570 92.8% Sales Sales Sales Sales Sales Entrace Womans Mens IT room Cut room Elec room RTU8 6000 5000 na 5600 93.3% RTU9 6000 4800 na 6100 101.7% RTU10 4000 3400 na 3800 95.0% RTU11 4000 3500 na 3980 99.5% RTU12 4000 3500 na 4020 100.5% D-2 200 170 na 190 95.0% EF -1 275 203 256 257 93.5% EF -1 275 234 240 242 88.0% EF -2 330 320 na 310 93.9% EF -3 150 140 na 142 94.7% EF -4 150 145 na 144 96% TOTAL 67180 55212 #VALUE! 64785 96.4% #DIV/0! REMARKS © 2017 NCI, Inc. CB206-08/17 DATE 05/10/18 PROJECT Floor & Decor 1761 Southcenter Parkway, Tukwila, WA SYSTEM Roof top Units / Gas forced air AREA SERVED SALES READINGS BY Sergey Pavlov Cert# 16-164-09 V Z 2 V w 2 1— w lel CI RTU 1-12 REcF/vE ) C?T Y OF rtal.WhhA OCT 0 8 2019 PERMIT CENTER nwevEn CITU OF TUKWF AIR AND BALANC REPORT FAN NAMEPLATE MFG: LENNOX MODEL LGHO6H4EU4G SERIAL 5618A06100 SIZE 5.0 TONS LOCATION Offices, Breakroom, Storage, TAG: RTU -13 REGISTERS AND GRILLES Room 'Training 'Corridor 1 Name Outlet D-1 Design CFM 400 w Qr�ll 505 415 405 101.3% 0-1 75 110 109 77 102.77o CEM D-1 175 131 166 170 97.1% Cash D-2 150 138 145 147 98.0% Vault D-2 150 127 138 140 93.3% Assistant RM 0-1 150 121 141 142 94.7% Break RM 'Womans Restroom 0-1 350 405 380 388 110.9% D-3 175 153 161 166 94.9% Mens Restroom D-3 175 146 163 162 92.6% Sign D-4 50 90 51 51 102.0% Corridor 2 O -1 100 107 100 100 100.0% Storage RM O -1 100 95 96 95 95.0% #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! TOTAL 2050 2128 2065 2043 99.7% #DIV/0! REMARKS © 2017 NCI, Inc. CB206-08/17 DATE 05/10/18 PROJECT Floor & Decor 1761 Southcenter Parkway, Tukwila, WA SYSTEM Rooftop Units / Gas forced air AREA SERVED Offices / Restrooms READINGS BY Sergey Pavlov Cert# 16-164-09 J 0 Z 2 ci w 1- w cc 0 LA OCT 0 8 2019 PERMIT CENTER ED Ci Y OF TUKWILA JUN 20,, 2018. PERMIT CENTER Project Information LE MX Product Submittal vw- 1 9 g Project Name: Floor & Decor - Tukwila, WA (REVISED -ADDED 24" ROOF CURBS) Project Number: 3000715059 Project Location: 17601 S CENTER PARKWAY TUKWILA, WA 17401, US Project Altitude: 1000 Customer Information Company Name: Floor & Decor Outlets Of America Tiglas Engineering Assoc., Inc MT 12-20-17 A 0 RA Company Address: 2233 LAKE PARK DR SE STE 400 FURNISH AS SUBMITTED EVISE ND RESUBMIT 0 REJECTED 0 SUBMIT SPECIFIED ITEM Company Location,: SMYRNA, GA 30080-8851 111 FURNISH AS CORRECTED Reviewed for roof curb only, all other please see COMMENTS previOuS submittal Contact: Phone: 404-471-1634 Engineering Information Corrections cr comments made on the shop timings during thls mime do not relieve ecntrector frorn compliance with requirements of the et-ovcrias end specifecticris This thee*n only for review of genenol conformance WO the (lesion 4;171cC Pt 'Di the project and general compilance with the information given In The contract documents. contractor ts responsible ter: conhrming and esmelathg I ciannies &maims coordinning NS work with that of di trade% ond performing his work In e—acts.cznisstiedartizie.ramaar 0 Company Name: Company Address: Company Location: Contact: Phone: We are pleased to provide the attached project submittal. Ifyou have any questions or need additional information, please feel free to call our office. Project: 3000715059 Floor & Decor - Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 1 of 28 Last Changed: UEHLINGER, HOMER Prepared On: 2017-12-18 Phone: 404-471-1634 Lennox Industries Inc. Product Submittal Table of Contents System ID Qty Model Description ' RTU 1,3,7,9 4 LGH180H4M PKGGE/15TON/CONFIGURABLE RTU 2,4,5,6,8 5 LGH180H4M PKGGE/15TON/CONFIGURABLE RTU 10-12 3 LGI-1120H4M PKGGE/10TON/CONFIGURABLE RTU 13 1 LGH060H4E PKGGEISTON/CONFIGURABLE Project: 3000715059 Floor & Decor - Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 2 of 28 Last Changed: UEHLINGER, HOMER Prepared On: 2097-12-18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID; RTU 1,3,7.9 Package Model: LGH180H4M Description: PKGGE/I5TON/CONFIGURABLE HEATING PERFORMANCE Unit Type HIE LowInput WE Low Output WE Highlnput HIE HighOutput System HeatOutput Packaged Gas 'Electric 169000 (Btuh) 135200 (Btuh) 260000 (Btuh) 208000 (Btuh) 208000 (Btuh) Gas Supply Connection WE Heat Rise AFUE/ TherrnalEff Number of Heating Stages Gas Supply Pressure 1.00 (in.) 32.1 (°F) 80 2 7 (in,WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARU NetTotalCool Coil GrossTotalCool Unit NetTotalCool Coil GrossSensCooi Unit NetSensCool Environ Refrigerant Charge Tube/Fin :Refrigerant Charge Tube/Fin Humiditrol Refrigerant Charge R -410A. 12.0 13.7 14300 (W) 176000 (Btuh) 172000 (Btuh) 182100 (Btuh) 175170 (Bath) 138396 (Btuh) 131466 (Btuh) 17 LBS. 8 07. 37 LBS, 8 O7. 41 LBS. 8 07. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 3 2 1.00 (in.) 95.0 (°F) 80.0 (°F) 67.0 (°F) 57.3 (°F) 56.9 (°F) 58.4 (°F) 57.3 (°F) 41.2 (Ib'hr) 41.2 (lbfJii ) HIJMIDITROL PERFORMANCE Humid -1st CoilDisehDB Humid -1st CoilDischWB Humid-AI1 CoilDischDB :Humid -All. CoilDischWB 74.3 (°F) 63..7 (°F) 66.3 (°F) 60.3 (°F) Humiditrol OutdoorDB Humiditrol MixedDB Humiditrol MixedWB Humid -i st MoistRemoval Humid -All MoistReniova.l. 95.0 (°F) 80.0 (°F) 67.0 (°F) 28.2 (Ib/hr) 38.9 (Ib/hr) SUPPLY FAN PERFORMANCE Supply AirFlow ExtStatiePress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 6000 (cfin) 0.50 (in.WC) 2.29 (hp) 5.00 (hp) MSAV Belt Drive 733 (rpm) 685 (rpm) 856 (rpm) TotalStatiePress Wet Coil Static Press Gas WE Static Press Added Filter Static Press Humiditrol Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.66 (in.WC) 0.03 (in.WC) 0.07 (in.WC) 0.03 (in.WC) 0.03 (in.WC) 6 24.0 (in.) 24.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA. Cooling FLA Total Unit Oper Range -Nona Voltage 460V 3Ph 60 (Hz) 39.0 (amp) 45 (amp) 24.0 (amp) 36.8 (amp) +-1- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 7.6 (amp) 5.2 (amp) 1500 (UVJ) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 91.1 (in.) 132.6 (in.) 54.3 (in.) 2632 (Ib) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 15.0 (itt.) 60.5 (in.) Projects 3000715059 Floor & Decor - Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 3 of 28 Last Changed: LIEI-{LINGER, HOMER Prepared On: 2017-12.18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU L3,7,9 Package Model: LGH144H4M Description: PKGGEI15TON/CONFIGURABLE SOUND Outdoor Sound Rating 93 (db) Project: 3000715059 Floor & Decor- Tukwila, WA Quote: 4000868238 Floor & Decor Tukwila, WA Page 4 of 28 Last Changed: UEMLING'ER, HOMER Prepared On: 2097.12.18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 1,3,7.9 Package Model: LGHISOHLIM Description: PKGGEJ15TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor ' Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comh. Gas Control Valve Electronic Flame Sensor Direct Spark ignition Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFCI - FACTORY ll'NISTALLED/NON-POWERED HUMIDITROL STANDARD CAP 2 IN MERV8 FILTER DRAIN PAN OVERFLOWSW MUM -STAGE AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM MSAV BLOWER BYPASS DUAL ENTHALPY ECONOM1ZER/W HOOD BAROMETRIC RELIEF DAMPERS/W 1400D PHASE MONITOR DISCONNECT WEATHERPROOF RA SMOKE DETECTOR INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 11E61 17M50 13T12 4 4 4 ClCUR1373C-1 DNFLOW HYBRID CURB 24" COSNSR3I AEI- SENSOR KIT, REMOTE HUMIDITY Cl GARD51C21 MESH HAIL/COIL GUARD Protech 3000716059 Floor & Decor - Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 5 of 28 Last Changed: HEHLINGER, HOMER Prepared On: 2017.12.18 Phone: 404-471-1634 Lennox Industries Inc . - Product Submittal System ID: RT11 1,3,7.9 Package Model: LGH180H4M Description: PKGGEII5TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY LGH 18O Model Mo. AA BB CC DD EE FF lbs. kg lbs. kg Ib.. kg lbs. I kg iti. nim in. I mitt LGH180 Std. Unit 407 230 476 224 622 293 636 1 300 53-14 1353 39-112 I 1003 LOW 80 M. Unit 597 232 567 263 652 308 699 1 330 52 1321 42 1 1057 9IC_ tilt -The unt Ai , M0 o?T I[1M. Mex Lm -The urdtAn) ALL CPTICNS InstlIec :Eca,anlxr. elt.) fiP1-1A9 nzl: AA O?TIOt4AL 1SCONRECT I; xclery.lresialled4 OAS SIJ 'LY.NLE' tlYit Ez.IL•Ail - -_ GasEts,41 YOIIt♦I _ `JI -11I __ (1376) 1.1.2} ly {331 4-1A '1081 12,'§8 60-172 (1537) :374) 15 :3311 33Tra 1 RETURN III AIR Ceo 1NG A BOTTOM SUPPLY 14 AIR.°PEN9L= tCo7; .` 121 BB •, •- ROTTON: POWER ENTRY TOP VIEW ,.. i1PTIONA!. In VO_TOUT !ET ;f strory I -Y:-a1IM I ft.r.18 LOU) 01-t,8i7.31n1 BASE SI0C ELGC"TR.CA IALLTS END VIEW Project_ 3000795059 Floor & Decor - Tukwila, WA Quote: 4000868238Floor & Decor - Tukwila, WA Page 6 Of 28 12101 341 (53) 4 _ i GAS P.LLP .Y. t4fT 6 LIFTIYG I1CLE3 122-5Z6 L13a.) FUJIE OUT L Ei CC FOR41FT SLOTS (152) !Tofly (f alYd Lefl Gide '; fisYi a v mit) 107-31(2737) BASE SIDE VIEW ;645; Last Changed: UE HUNGER, HO ER Prepared On: 2017-12-18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU L3,7,9 Package Model: LGH 80H4M Description: PKGGEi15TOI (CONFIGURABLE ACCESSORY DIMENSIONS • INCHES (MM) Project: 3000715059 Floor Quote: 4000868238 Floor Page 7of28 OPTIONAL OUTDOOR MR HOOD DETAIL WITH STANDARD STATIC POWER EXHAUST FANS 16 Gip r OPTIONAL OUTDOOR ,MR HOOD (Factory or Feld Takata!) Rewired voth Eau mcr or Odd= Ar Damper ' OPTIONAL STANDARD STATIC POWER 'EXHAUST FANS HOOD (Fiat Instated) Decor - Tt vita, WA Decor - Tukwila, WA Last Changed: UERLGMGER, HOMER Prepared On: 2017.12.18 Phone: 404-471-1634 Lennox Industries Inc. Product Submittal System ID: RTU 1,3,7.9 Package Model: LGH 180H4M Description: PKGGEl15TONTCONFIGURABLE HYBRID ROOF CURBS - DOUBLE DUCT OPENING TYPICAL FLASHING DETAIL FOR ROOF CURB BASE ISOTTOM ` (PACKAGED FtSERGLASS IN tLAT1OP. (Fu tm) NAILER STRIP ROOF CURB (Extondr around untie Pedelettr d van R'I3I D INSULATION jFiull Sup�iod COON -TER IRA -SI -00G j (Rob SlarOW G�( CANT STRIP III 1 Fl3l, Suppled) ROOFING . grA/1:;F / PAATEPJAL Project: 3000715059 Floor & Decor - Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 8of28 DETAIL ROOF CURB ti=34y (44) -h �■ 1/2 (13) 6 203) 14 356 18 '45-0 24 61 L1 1 FACTORY INSTALLED PE/kir/ma moo NAILER STRIP I' '1 (44) Last Changed. UEHLINGER, HOMER Prepared On: 2017-12.18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal, System ID: RTU 1.3,7.9 Package Model: LGH 180 4M Description: PKGGEI15TO /CONFIGURABLE UNIT CLEARANCES - INCHES (MM) Unit With (Economizer /f/ isovg 7 ///...../A , _ Top Clearance /// A /./1/ Note: 210-240-300 sizes crown ' Unit Clearance Top Clearance in. nim in. mm in, rens on. mm Service Clearance 59 '1121 36 I P',4 38 93.1 88 1575 tlnohstnirtFd Clearance to Combustibles 38 914 1 i 25 1 2.5 1 25 Minimum Operation Clearance 45 1143 36 ! 914 36 914 41 1341 NOS -attire arsinx er aunit:49e wet me Rupp ort *Ten above tole rncuillgsurface. Sxrvrce eleannaa - Aaxutxi far rsrrxrval d vanicsaal; pars: Clearance to conbustnates - Rectured macanse t0 OntuEutle;n319n31 r�: IImEl1 Operation Clearatce - Re -aired :fear;rruce tec proper n rpt enematn. Project: 3000715059 Floor & Decor - TnFkw�nla, WA Quote: 4000868235 Floor & Decor - Tukwila, WA Page 9 of 28 Last Changed: UEHLINGER, HOMER Prepared On: 2017.12-18 Phone: 464-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 2,4,5.6,8 Package Model: LGH180H4M Description: PKGGE/15TONTCONFIGURABLE HEATING PERFORMANCE Unit Type H/E Lowlnput WE LowOutput HIE Highlnput H/EHighOutput System HeatOutput Packaged Gas Electric 169000 (Btuh) 135200 (Btuh) 260000 (Blab) 208000 (Btuh) 208000 (Btuh) COOLING PERFORMANCE Gas Supply Connection HIE Heat Rise AFUE/ ThennalEff Number of Heating Stages Gas Supply Pressure L00 (in.) 32.1 (°F) 80 2 (in.WC) Refrigerant AR1 EER AR1 IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossIondCool Unit NetTotalCool Coil GrossSensCool Unit NetSensCool Environ Refrigerant Charge Tube/Fin Refrigerant Charge TubefFin Humiditroi .Refrigerant Charge R -410A 12.0 13.7 14300 (W) 176000 (Btuh) 172000 (Btuh) 182100 (Btith) 175382 (Btuh) 138396 (Btuh) 131678 (Btuh) 17 LBS. 8 01. 37 LBS. 8 01. 41 LBS. 801 Number Compressors Number of Cooling Stages Condensate DraM Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureR emoval System MoistRemoval 3 2 1.00 (in.) 95.0 (°F) 80.0 (°F) 67.0 (°F) 57.3 (°F) 56.9 (°F) 58A (°F) 57.3 (°F) 41.2 (IMO 41.2 (Ib/hr) SUPPLY FAN PERFORMANCE Supply .AirFlow ExtStaticPress Supply SupplyFan Req"dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 6000 (dm) ° 0.50 (in.WC) 2.22 (hp) 5.00 (hp) MSAV Belt Drive 721 (rpm) 685 (rpm) 856 (rpm) TotalStaticPress Wet Coil Static Press Gas HTE Static Press Added Filter Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.63 (in.WC) 0.03 (in.WC) 0.07 (in.WC) 0.03 (in.WC) 6 24.0 (in.) 24.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency . System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 39.0 (amp) 45 (amp) 24.0 (amp) 36.8 (amp) +/- 10% SupplyFain FLA CondensingUnit FLA CondenserFan Power 7.6 (amp) 5.2 (amp) 1500 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 91.1 (in.) 132.6 (in.) 54.3 (in) 2477 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Returtri Width 20.0 (in.) 28.0 (in.) 15.0 (in.) 60.5 (in.) SOUND Outdoor Sound Rating 93 (db) Project: 3000715059 Floor & Decor - Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 110 ar 28 Last Changed: UEHLINGER, HOMER Prepared On: 2017-12.18 Phone: 404471.1634 Lennox Industries Inc. - Product Submittal System ID: RTU Package Model: LGH180H4M Description: PKGGEII 5TONICONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint finish Scroll Compressor Pre -charged Refrigeration System High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Frodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and :Limit Controls Factory Test Operated `Bonded for Grounding internal Pressure Relief Valve Overload Protection Crankcase Heater Test Timed Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark ignition Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on Environ Coil System of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED CFO - FACTORY INSTALLED/NON-POWERED STANDARD CAP 2 IN MERV8 FILTER DRAIN PAN OVERFLOW SW MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS ENVIRON COIL SYSTEM MSAV BLOWER BYPASS DUAL ENTHALPY ECONOM1ZER/W HOOD BAROMETRIC RELIEF DAMPERS/W HOOD PHASE MONITOR DISCONNECT - WEATHERPROOF RA SMOKE DETECTOR 'INCLUDED SYSTEM OPTIONS - .FIELD INSTALLED I iFfoi 15T93 5 5 Cl CURB73C-1 DNFLOW HYBRID CURB 24" GARD52C22 MESH RA1L/COIL GUARD Project: 3000715059 Floor & Decor - Ttikwila, WA Quote. 4000868238 Floor & Decor - Tukwila, WA Page 11 of 28 Last Changed: UEHLINGER, HOMER Prepared On: 2017-12-18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 2,4,5,6,8 Package Model: LGH l80H4M. Description: PKGGE/15TON(CONFIGURABLE DIMENSIONS - INCHES (MM) NER WEIGHTS CENTER OF GRAVITY LGH18Q Model No. AA BB CC DD E=E FF lbs. :kg lbs. kg lbs. kg ]bs 1 kg in. mm in. I ram 1_01-1190 Std. Unit 497 230 478 224 622 293 636 I 300 53-14 1353 39-112 1 1003 LGH190 Max. Unit 597 232 567 263 652 308 699 1 330 52 1321 42 ( 1087 8I . l nt-Ira urrix+lh NOOP'iILiN3. Aim Urn( -Fre unit'alln ALL CP'TLCNS In5lsllec :Ecanonixr. et.) AA OU 4.11 '1081 l2 aar2 (1537} ;3141 151331; DOTTCG1 RETURN 4 AIR CPENtiG 1a 11144 i oTTC,t SUPFLY ;JR OPEN: X11\ 4 ' .35 7117'1 X711: 1711? 2113}3)ir i EE 1 1 CENTER OF GRA/ITN Fl BB — - ROTTON: PO/47i ENTRY A X Aix:i,, 112: X743 mina TOP VIEW CC 132,51s DI SCON'1LCT 11. VO' T 0I01 ET (Factay Install --dl ;F11±n,ry Iti-}-agm I!t 1e (hit) r COhDENS .TE DRAIN GAS SUt1LY ;NLE- Gas Sul?. OiuIyl (!3e} 54414 (1356) 1-12 , 133: SIDE SLECTRCt IALLTS 31- 85,$23161 END VIEW Project: 3000795059 Floor & DEICor = Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila. WA Page 12 of 28 a -LK 1210; 3441 1 I GAA $IJP N f IJI FT ,.{ OUTLETS 6 LIFTING FiCLE3 €IZiMFT SLCT6 O04 ca521 (Fix Riggiu iFmY. and LCB Gide Only; Fsri sr' A) 107.344 (273%Y 2sas BASE 1845; SIDE VIEW Last Changed! UEHLINGER, HOMER Prepared On- 2017-12-16 Phone, 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 2.4.5,6,8 Package Model: ;LGH18OH4M Description: PKGGEJI.5TONJCONFIGURABLE ACCESSORY DIMENSIONS • INCHES (MM) OPTIONAL OUTDOOR AIR HOOD DETAIL WITH STANDARD STATIC POWER EXHAUST FANS 16 (406/ r— OPTIONAL O1rno A1R14000 (Factory or Field tri) Rired with ger or OuRmor AF Dampcx ' OPTICd4AL STANDARD STATIC POJVER EXHAUST FANS 14000 (Field Installed) Project: 3000715059 Floor & Decor = Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila; WA Page 13of28 Last Changed: UEHLINGER, HOMER Prepared On: 2017-12-18 Phone: 404=471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU Package Model: LGHl 80114M Description: PKGGE/ I 5TON/CONFIGURABLE HYBRID ROOF CURBS - DOUBLE DUCT OPENING E16-1/8 12188) --RETURN ENING, 61-1/2 OSS2) 1CQ {2591) — SUPPLY .B14/2 (2070)„ aS-112 (2502) TYPICAL FLASHING DETAIL. FOR ROOF CURB EA:SEISM-IOU PACKAGED 7" liner IRSERGLASE INSULAIION (E(rckateci) MAILER STRIP (P ~CO) 1100P CURB (EglAke8 around camp Pestmelcc d Wig Ram INSULAT/ON fFlekl Simitioe8 COO/ITER fLASHLNO {Fred StaARKI) CANT STRE, ROOFING ine4118LIPP444) :17143- Project: 3000715059 Floor & Decor - Tukwila, WA Quote: 4000868238 Floor & Decor - Ttikwila, WA Page id or 28 > 1 1 1NTR, 24 r18(45 NOTE - Root del& rrl ay ba oisitidd callinta of act. DETAIL ROOF CURB 6 14 18 24 I -3/4r 1/2(13) FACTORY INSTALLED PERIMETER MOD NAILER STRIP 1-3/4 (44) Last Changed' UEHLINGER, HOMER Prepared On: 2097-12-98 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System IIA: RTL) Package Model: LGH 180H4M Description: PKGGE/15`FON/CONFIGURABLE UNIT CLEARANCES - INCHES CMM) Unit With !Economizer /0AR A 11000 // //./A( /l/e fi 07 /7 / ..af 7 / F // ! r //ffJ/,:"fes Nae: 210.240-300 slaes shonun .. Unit Clearance A B C D Top Clearance in. nim in_ mm in. mrn in_ mm Service Clearance 60 '524 36 j A-,4 36 93.1 65 1570 Ilnnhstnict d Clearance to Combustibles 36 F1 1 1 1 25 1 2.6 1 26 Minimum Operation Clearance45 1143 3.13 9'4 36 914 41 1:141 NOM - Wire orsinwler or Unit'owe requires support *ten ee.^a?eCi rncow@ nuance. ' Sevvrcra Cloamtxa - Banti tar rerxnal d senirea* par s. Clearance to Conibustmtes - RegJF€C veararde to lSontueutie t71atan.t Pitini ratan Operation Ciearatonce - Frtaircai r;earancrtur-pruper cre:Op&IYBec. Project: 3000715059 Floor & Decor Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 15 of 28 Last Changed: DEHLIINGER, HOMER Prepared On: 2017-12-18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 10-12 Package Model: LGH120H4M Description: PKGGE/10TOWCONFIGURABLE HEATING PERFORMANCE Unit Type WE Lowinput WE LowOutput HIE Highinput H/E IiighOutput System HeatOutput Packaged Gas Electric 117000 (13ht) 93500 (BUM) 180000 (Btuh) 144000 (Btuh) 144000 (Btuh) Gas Supply Connection 11/E Heat Rise AFUE1 ThennalEff Number of Heating Stages Gas Supply Pressure 0.75 (in.) 33.3 (°F) 80 2 7 (in,WC) COOLING .PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI. NetTotalCool. Environ Refrigerant Charge R =410A 12.0 13.8 9800 (W) 122000 (Btuh) 118000 (Btuh) 14 LBS. '120Z, Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB 2 2 1.00 (in.) 95.0 (°F) 80.0 (09 67.0 (°F) SUPPLY FAN PERFORMANCE ExtStaticPress Supply SupplyFan NomPower Supply Fan Type SupplyDrive Min RPM SupplyDrive Max RPM 0.50 (in.WC) 3.00 (hp) MSAV Belt Drive 730 (rpm) 970 (rpm) TotalStaticPress Gas WE Static Press. Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.94 (in.WC) 0.21 (in.WC) 0.04 (in.WC) 0.19 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range4Vom 'Voltage 460V 3.Ph 60 (Hz) 26.0 (amp) 30 (amp) 16.0 (amp) 23.4 (amp) +1- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 4.8 (amp) 2.6 (amp) 800 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1388 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (M.) 24.0 (in.) 27.0 (in.) SOUND Outdoor Sound Ratios 88 (db) Project: 3000715059 Floor & Decor - Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 18 of 28 Last Changed: UEHLINGER, HOMER Prepared On: 2017-12-18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 10-12 Package Model; LGH12OH4M Description; PKGGEll OTONICONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature ,in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Beater Test Timed On -Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Cornb Gas Control Valve Electronic Flame Sensor Direct Spark 'pinion Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on Environ Coil System of 3 years Limited warranty on all other components of I year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OP -TIONS - FACTORY INSTALLED GEO - FACTORY INSTALLED/NON-POWERED STANDARD CAP 2 IN MERV8 FILTER DRAIN PAN OVERFLOW SW MULTJ-STAGE AIR VOLUME HINGED ACCESS DOORS ENVIRON COIL SYSTEM MSAV BLOWER 'BYPASS DUAL ENTHALPY ECONOMIZERIW HOOD BAROMETRIC RELIEF DAMPERS'W HOOD PHASE MONITOR DISCONNECT - WEATHERPROOF RA SMOKE DETECTOR INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 1,1E57 3 ClCURB73B-1 DNFLOW HYBRID CURB 24" I3T05 3 CJGARD52B-3 MESH HAILICOIL GUARD Project- 3400715059 Floor & Decor Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 17 of 28 Last Changed: UEHLINGER, HOMER Prepared On: 2017-12-18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 10-12 Package Model: LGH 1 20H4M Description: PKGGEII10TONICGNFIGURABLE SII® 5-1Nal ES't Model No. CORNER WE NTS CENTER OF GRAVITY AA BB CC OD EE FF Base Max. Base Max. IBa6e ' Max. Base Max. Base Max. Base Max, lbs. Ikg lbs. 1kg ilbs. kg lbs. kg Ibs. kg 1ibs. kg Ibs. kg lbs. kg In. Imnt in. mm in: mim in. mm 092 293 133 338 153 283 119 295 134 285 130 316 143 325 148 370 168 46.5 1181 45.5 1156 24.5 622 25.5 848 102 294 134 340 '154 285'120 297 135 288 131 318 144 328 149 372 189 46.5''1981 45.5 1156 24.5 622 25.5 848 120 306 139 349 158 275 125 305 '138 295 134 325 148 334 152 382 173 46.5 1181 45.5 1156 24.5 622 25.5 848 150 316 143 359 163 284 129 314 142 304 1381393 178 345 157 393 178146.5 1181 45.5 1156 24.5 622 25.5 648 sate i.k4- The vat wt1!ra0 NTERNALOP11ONS. 1Aar. x- The u8aWIN ALL TNT BINALOP11ONS'kstmie8 TEOC .Titit•t, SttrxltrdSmitPO E, 5TMFans, cdeifen),,,em.}.DstsnatitthAlta06Cs3er 8e emein urdiorhigh a9atiopower ct tspa 04rs 2 II8t*1 OTlSUPPLY 042)} Ali OPE MN% ri1(a— (tSE) Wo -V3(1 EASE BOTTOM POWER ENPRY 18412 4 to:4 oil END VIEW Project: 3000715059 Floor & Decor - T& kwila, WA Quote: 4000868238 Floor & Decor -Tukwila, WA Page 18 of 28 24 tG1r1} IO,'t4 4271 20 45m81 2T BOTTOM RETURN AIR OPENING 7 078) ino EE 28 — (7Lr} Q7ERATTMR d FF 7 48781 34.78 NSA 101.17E 8Ass. [1872) TOP VIEW 7!5.184 OP'TI0ar41..ID0xr1X4NECT..: 1-2[10 (FACTORrrIA ED) 125) CONDENSATE4/ SGPPt ORi.85J 1888017 / INIJET 641.8 (837} ELECTRIC w1ETS a RUE 471€i Ol2j f Ir ORNiUT SLOTS. 48D?W'SJEES) L, - THOLES 4FOR MGMCO) 101.110 (2572) SIDE VIEW I_t 7M 4ti S+1) IHORIZONTFt 9UPP1.YAJR OPEite4G SIDE VIEW {.1 o TIzon isl Openings) Last Changed: UEHLINGER, HOMER Prepared ©n': 2017-12.18 Phone:, 404-471-1634 dTs 438 (1az. ,111[z•7 END VIEW Project: 3000715059 Floor & Decor - T& kwila, WA Quote: 4000868238 Floor & Decor -Tukwila, WA Page 18 of 28 24 tG1r1} IO,'t4 4271 20 45m81 2T BOTTOM RETURN AIR OPENING 7 078) ino EE 28 — (7Lr} Q7ERATTMR d FF 7 48781 34.78 NSA 101.17E 8Ass. [1872) TOP VIEW 7!5.184 OP'TI0ar41..ID0xr1X4NECT..: 1-2[10 (FACTORrrIA ED) 125) CONDENSATE4/ SGPPt ORi.85J 1888017 / INIJET 641.8 (837} ELECTRIC w1ETS a RUE 471€i Ol2j f Ir ORNiUT SLOTS. 48D?W'SJEES) L, - THOLES 4FOR MGMCO) 101.110 (2572) SIDE VIEW I_t 7M 4ti S+1) IHORIZONTFt 9UPP1.YAJR OPEite4G SIDE VIEW {.1 o TIzon isl Openings) Last Changed: UEHLINGER, HOMER Prepared ©n': 2017-12.18 Phone:, 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 10-12 Package Model: LGH120H4M Description: PKGGVIOTOWCONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL OUTDOOR AIR HOOD (Furnished with Ecomornizer or Outdoor Air Dariper) EXHAUST AIR FOOD (funniMed, Field Installed) Prclect: 3000715059 Floor & Decor - Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 19 of 28 (FA1) Lest Changed: UENLFNGER, HOMER Prepared On: 2017-12-18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU W-12 Package Model: LGH1201-14M Description: PKGGEll OTON/CONFIGURAB LE HYBRID ROOF CURBS DOUBLE DUCT OPENING 518 (2723) 9 42334) 26-3fil 54414 (i378) 50-318 (1289 TYPICALIFIASH/NG DETAIL FOR ROOF CURB FIB 9A .sOTT/ EF0 NAKERSTRN frotrkm4 IROCP CURB. itEoliwi$800001Ntly8 880A11081,tonla. 11112,0 InSULATION Irti SIPIRKO ° .a1 I r I A ourr$T1IF 1 P MEN EN1P%0 a OOKENG -0 41,4'''-'2•77 A a 077,A07 PACKAGED CO1POEPPLA-NING (R811 SWANN Project: 3000715059 Floor & Decor - Tukwila, WA Quote: 4003868238 Floor & Decor . Tukwila, WA Page 20 of 28 NOTE - Nm1 deck 0v8ybe «riHd WIrriM t_ Anti DETAIL ROOF CURB 88203) 18 ma) 181481) 24,1610) , (44) are (13) FAL. 1 014i INSTAUED PERIVEPOI WOOD NAILER'STR1P 1-381 Lest Changed: UEHLINGER, HOMER Prepared On2017.12-18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 10-12 Package Model: LGH120114M Description: PKGGV1OTONICONFIGURABLE UNIT CLEARANCES - I LACHES (MM) Vey ' Unit Clearance U1.1113NAL B •,-.••_- --'?' /= ..i .. .% •i • .? '-71.,41_ D Top Cloorailc, Ull MUM rnm • mm In. Ala HOOD in. mm Senile Clearance 60 1524 36 914 ..7.j,„ .11-11.t:lic. 934 60 1524 . Unobstructed Clearance to Combustibles -111144 e°7" L.' 8 4 ' Unit Clearance A B C D Top Cloorailc, in. rnm In. mm In. mtn in. mm Senile Clearance 60 1524 36 914 36 934 60 1524 . Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE -Erilin-.1 off .01 tifil uqIiiIc Hr.ii whrti rif Ailno!) &grave Clearance - RewArEdicr ren-cra seriiceablz• p3r5. Clearance ID Contuslble9 - Ilelikedcleararo:elD corrl 7 -BIM!? matenai. Witilincruf)po ni hut rival vnitx: Rooirsi fasivalia! FII Iv-qr.:1 tixItrithi! Preject: 30+30715059 Floor & Decor = Ttrkwila, WA Ouote: 4000868238 Floor & Decor - Ttrkwila, WA Page 21 of 28 Last Changed: UEHLINGER, HOMER Prepared On: 2017.12.18 Phone 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 13 Package Model: LGH060H4E Description: PKGGE/5TON/CONFIGURABLE HEATING PERFORMANCE Unit Type R/E Lowlnput HIE LowOutput HIE Highlnput HIE HighOutput jirstern HeatOutput Packaged Gas Electric 81000 (Btuh) 65000 (Btuh) 108000 (Btuh) 86000 (Btuh) 8,6000 Gas Supply Connection WE Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 39.8 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant R -410A ARI EER 12.7 ARI SEER 17.0 ARI Total Power 4700 (W) AFI GrossTotalCool 61600 (Btuh) ARI NetTotalCool 60000 (Btuh) Errviron Refrigerant Charge 7 LBS. 5 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB 2 1.00 (in.) 95.0 (°F) 80.0 (°F) 67.0 (°T) SUPPLY FAN PERFORMANCE ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower • Supply Fan Type 0.50 (in.WC) 1.00 (hp) 1.00 (hp) MSAV Direct Drive TotalStaticPress Gas HTE Static Press Added Filter Static Press Economizer Static Pre -ss Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.64 (in.WC) 0.04 (in.\VC) 0.05 (in.WC) 0.05 (in.WC) 4 20.0 in. 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (I -1z) 15.0 (amp) 20 (amp) 9.0 (amp) 14.8 (amp) 4/- 10% SupplyFan FLA CondensingUnit FLA 3.7 (amp) 2.1 (amp) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 46.9 (in.) 882 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND. Outdoor Sound Rating 82 (db) Project: 3030715059 Floor & Decor = Tdkwila, WA Quote 4000868238 Floor & Decor - Tukwila, WA Page 22 of 28 Last Changed: UEHLINGER, HOMER Prepared On: 2017-12-18 Phcrne: 404-471-1634 Lennox Industries nc. - Product Submittal System ID: RTU 113 Package Model: LGH060H4E Description: PKGGE/5TON/CONFIGU BLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Pre -charged Refrigeration System High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodio unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Test Tuned Off Control AGA -CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb, Gas Control Valve Electronic Flame Sensor Direct Spark ignition Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Lirnited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GFC1 - FACTORY .INSTALLED/NON-POWERED STANDARD CAP 2 IN MERV8 FILTER DRAIN PAN OVERFLOW SW MULTI -STAGE AIR. VOLUME HINGED ACCESS DOORS ENVIRON COIL SYSTEM DUAL ENTHALPY ECONOMIZERIW HOOD BAROMETRIC RELIEF DAMPERS/W. HOOD DISCONNECT kVEATHERPROOF RA SMOKE DETECTOR INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 1F53 13T0.3 CI CURB73A-1 DNFLOVer HYBRID CURB 24" GARD5I ATI MESH HAIL/COIL GUARD Project: 3000715059 Floor & Decor - Tutmla, WA Quote 4000868238 Floor & Decor - Tukwila, WA Page 23 of 28 Last Changed! UEHUNGER, HOMER Prepared On: 2017-12-18 Phone: 404-471-1634 J 4 Lennox Industries Inc. - Product Submittal System :ID: RTU 13 Package Model: LGH060H4E Description: PKGGE/STON/CONFIGURABLE DIMENSIONS INCHES IMM) CORNER WEIGHTS 1 CENTER OF GRAVITY Model No. AA BB CC DD EE FF lbs. kg lbs. kg lbs, kg lbs. kg "l In. mm tn. mm 1104036 Base Unit 98 45 919 54 192 87 158 72 38.5 978 18 457 I LGH036 Max. Unit 137 62 I 155 70 250 113 221 100 1 40 1016 18 457 1104048 Base Unit 104 47 126 57 202 92 167 _ 76 38:5 978 18 457 I LGH048 Max. Unit 145 66 164 74 264 , 120 233 106 ' 40 1016 18 457 11-G11060 Base Unit 118 54 144 65 232 105 191 87 3&5 978 18 457 I L.GH060 Max. Unit 164 75 165 84 299 136 264 120 'I 40 1016 18 457 ILGH072 Base Unit 132 60 160 73 258 117 212 96 38.5 978 118 457 I LGH072 Max. Unit 173 78 195 89 314 143 278 126 40 ' 1016 18 457 1101074 Base Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 I LGH074 Max. !Unit 173 78 I 195 89 314 143 278 126 40 1016 18 457 Base lkd - Tte unit rii NO NOIKIERMALOPTIONS. 7,13x lire: -The un)i e: m.L itTriBireNAL OPTIONS led. (rLorrornizer. mrd Stec Power Exhaust Fas. Coerlots, 5 J. n of IndtMe amessorirs 631.e1131 uria or high staficpoufs' exhaust. 548 1 RI1s} 7 (1 77) BOTTOM RETURN AGR 0 tI 00 END VIEW 1SS(4 1s' (413} 4457) 3 5(127) CASE CENTER OPENING 20 29 (737) sir (tee o OPENING of T GRAVITY I ll!! 11.\ 411114 } ' se}o— i IX- La (2411 UFOW *OM TLIGH0 Enc!spence Packaged Gas # ENctria 3 to 6 Ton Maw 52 Project: 3000715059 Floor & Decor = Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 24 of 28 min (87Ili u BOTTOM BOTTO Y POWER ENTRY COV13'ersATEO¢ina 3X4(76X 2321. . TOP VIEW (Base) jcc SIDE VIEW 11 1 R5) _83114 _} (211 tl ?54f2 �t_ aGh17E5`9AT a raeT E. - EIXOTRICAL GAS grit r (737 15 (351) -4140) tr2 02- ,Ca _? 16 i_.2_____ 1 6.112 7 (BM ?L 08E1854(21B) SIDE VIEW 11 1 R5) FORKLIFT SLOTS 1HO1117.0NTAL (Fant BIO nasi SUPPLY AP Sonnet tel) OPENING BACK VIEW ) 54/2 61EWR5 r L RWC) oneittO (1-4 542 (WinnutEannotiai) Last Changed: UEIILINGER, HOMER Prepared On: 2017.12-18 Phone: 404-471-1634 - _OgieL__-.o.sa (4934 _ _ (4671 -- - _ {_*3 (737 22 ) • FORKLIFT SLOTS 1HO1117.0NTAL (Fant BIO nasi SUPPLY AP Sonnet tel) OPENING BACK VIEW ) 54/2 61EWR5 r L RWC) oneittO (1-4 542 (WinnutEannotiai) Last Changed: UEIILINGER, HOMER Prepared On: 2017.12-18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 113 Package Model: LGH060H4E Description: PKGGE/5TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR NR H000 DETAIL FOR OPTIONAL ECONOMIZER AND BARON" URIC RELIEF DAMPERS Dcwn-Flow ApFlicatIons) PTIOI/A-CUICoae HLVD .+0 Ecammnr1 'e OF MOW_ GAR014.7.7FIC PGIAF HCOO r Sopra-fttcr! OUTDOOR AIR HOOD FOR ECONOMIZR (Furnis hod, 11 aoEL1Ao.* 7.5.7.d.0-ni M101 9ril .:"1? SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZE R (Furnished) Model in. rum A in. 936. 0,48 , 9-114 4B9 mm 13 330 in. mm 11-3/4 28 CED, 072 23-14 531 17 432 15-3g 230 Project: 3000715059 Floor & Decor - Tukwila, WA Quote: •400086823B Floor & Decor - Tukwila, WA Page 25 of 28 Last Changed: UEHLINGER, HOMER Prepared On: 2017-12-18 Phone: 404-471-1634 Lennox Industries Inc. - Product Submittal System ID: RTU 13 Package Model: LGH060114E Description: PKGGIEJ5TON/CONFIGURABLE HYBRID ROOF CURBS -DOUBLE DUCT 12-0 EN [NG TYPICAL FLASHING 'DETAIL :FOR ROOF CURB BASE IBOTTOM FSERGLASS NVIRAT NAILER STRIP friltMOlifid) ROOf CURE (ti:40 AfccoldtAliM gerimelei d ma) RIGID INSULATION (WSIPPOE'd) PACKAGED UN IT °GUNTER FLASHING V Pal SupgiNt) CANT STRIP (FiPM &PP Ir&cri ' 1300FAIG ,jr MATERIAL A drir.drOW Project: 3000715059 Floor & Decor - Tukwila, WA Quote: 4000868238 Floor & Decor - Tukwila, WA Page 28 of 28 DETAIL ROOF CURB 14_4,11-314 (44) Last Changed: UEHLINGER, HOMER Prepared On; 2017-12-18 Phone- 404-471-1634 Lennox Industries nc. - Product Submittal System ID: RTU 13 Package Model: LGH06OH4E Description: PKGGE{5TON/CONFIGIJRAELE UNIT CLEARANCES - INCHES (MM) CrJ it ovtt HOOD A ,, f• ' ":: > .. Alli D *1 !i,),I;I ,A`�� _ 1, f1 Top Clearance in. 1 thiit Clearance A B C D Top Clearance in. mm irt. mm in. mm in. rnm Service Clearance 49 121`'•] 39 914 30 934 30 911 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 I 914 36 914 36 914 NUI1_-t:r re3ennteteratunitbase wiressuppo:tutter+aleva`eclalxwe hemourning ;urtce. Rib ii!r: Clc>tiMu:to-- Ri:l1niiC:;f E>t ierlifYi;;1!rlf g<a�ii`.P.711iil l"r ri$ Clearance to Contbu5tlbles - Ideaule1 clearance tocat busitle rr.:.oera.. Minimum! 04x:i atinn C6:ri Inc r. Ri giii eras i .0 irxx: fin gaalr:1 .Til ept.i Alin t. Project 3000715059 Floor Quote: 4000868238 Floor Page 27 of 28 Decor Ttfkwile, WAS Decor - Tukwila, WA Last Changed: UEHLINGER, HOMER Prepared On: 2017.12.18 Phone: 404471-1834 Lennox Industries Inc. - Product Submittal MISCELLANEOUS MATERIALS X6523 CRP WIND SEISMIC RESTR BRKTS 87N53 EG T8100 -LN CO2 DETECTOR/WHITE/WALL COMSD Third Party CURBS PLUS 2510-13115 DIFFUS COMSD Third Party CURBS PLUS 2010-10/12,5 DIFF Project: 3000715059 Floor & Decor = Ttrkwila, WA Quote. 4000868238 Floor & Decor - Tukwila, WA Page 28 of 28 Last Changed° UEHLINGER, HOMER Prepared On: 2017-12-18 Phone: 404-471;1634 Bill Rambo From: Jerry Hight Sent: Monday, September 16, 2019 11:33 AM To: Bill Rambo Cc: Bill Centen Subject: Renewal of M17-0198 Apparently, mechanical permit M17-0198 experienced a TRAKiT error and was inadvertently canceled. Please reactivate so Bill can enter corrections. Jerry Hight Building Official City of Tukwila 1 RECEIVED CITY OF TUKWILA SFP 1 7 2019 PERMIT CENTER 11/1/2018 City of Tukwila Department of Community Development VANESSA MASELL 355 UNION BLVD - SUITE 301 LAKEWOOD, CO 80228 RE: Permit No. M17-0198 FLOOR & DECOR 17651 SOUTHCENTER PKWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/24/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/24/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M17-0198 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 °ERMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0198 DATE: 12/15/17 PROJECT NAME: FLOOR & DECOR SITE ADDRESS: 17601 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works M C 1)--)-1-1 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWERcS INITIALS: DATE: 12/21/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) 01/16/18 Notation: REVIEWERcS INITIALS: DATE: CPermif Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 DIRECT MECHANICAL CNTRCT" S LLC Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 A-ZIndex lielp • My L&1 Workplace Rights Trades & Licensing DIRECT MECHANICAL CNTRCTRS LLC Owner or tradesperson Principals PAVLOV, SERGEY VIKTOR, PARTNER/MEMBER PAVLOV, MARK VIKTOR, PARTNER/MEMBER PAVLOV, DANIIL VIKTOR, PARTNER/MEMBER PAVLOV, VIKTOR N, PARTNER/MEMBER Doing business as DIRECT MECHANICAL CNTRCTRS LLC WA UBI No. 602 922 445 PO BOX 872472 VANCOUVER, WA 98687 360-921-2175 CLARK County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ..................._..........._........ _.__..................._ Meets current requirements. License specialties GENERAL License no. DIRECMC913K0 Effective — expiration 05/20/2009— 06/24/2019 Bond ................ Wesco Insurance Co Bond account no. 46WB001062 Received by L&I 07/26/2012 Bond history $12,000.00 Effective date 07/18/2012 Expiration date Until Canceled Insurance ........._........_...... Mid -Century Ins Co $1,000,000.00 Policy no. 605067968 Received by L&I Effective date 12/26/2017 01/10/2014 Expiration date 01/10/2019 Insurance history Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602922445&LIC=DIRECMC913KO&SAW= 03/05/2018 DIRECT MECHANICAL CNTRCTRS LLC Savings No savings accounts during the previous 6 yL , period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ....................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations IVo license violations during the previous 6 year period. Workers' comp Do you know if the' business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 175,676-00 ................................. Doing business as DIRECT MECHANICAL CONTRACTORS Estimated workers reported Quarter 4 of Year 2017 "4 to 6 Workers" L&I account contact T2 / DALE RIUTTA (360)902-4834 - Email: RIUD235@ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes This contractor received a valid strike(s) for violation or infraction for the following L&I law(s). Learn more about contractor strikes. RCW Violation 18.27.200 Description Failure to comply with contractor registration requirements, per RCW 18.27 Contractors not allowed to bid No debarments have been issued against this contractor. Effective Date 4/1/2011 Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 i Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602922445&LIC=DIRECMC913KO&SAW= 03/05/2018 SM -20N ACROVYN 4000 WALL CONOMON SPECIFIED FASTENER DRILL DIAMETERS CS PART "USER WALL. RETAINER STmefUOAYPSUMWALL WOOD 8TUDIGYPSUNWALL Se K 1 SWSUGLE NEADSHEEr METAL SCREW 8014078002 AF-0PUSOCANCHOR90W8004 %EBLOCK 470 X1 lir PHILLIPS PAN HEAD SMS 4040 CONCRETE1CONCAEIE BLOCK 1I8•BLIND RIVET 90"111002 END CAP ATTACHMENT re SAE FLAT WASHER STEEL PLATED 0014010008 STEEL STUD (BY OTHERS) G.W.B. (BY OTHERS) REGRIND RETAINER (24U026000) CEILING 1/4" [6.4mm] CAP TOP & BOTTOM 1116" _ [1.6mm] TOP & BOTTOM #6 X 1 5/8" BUGLE HD SMS 18" [457.2mm] MAX. ACROVYN 4000 COVER (24U002)=) ACROVYN CHAMELEON (24U634xxx) FLOOR [76.1 mm] CORNER GUARD DETAIL SCALE: NTS BASE HGT. FLOOR PLAN LEGEND EXISTING WALL NEW MASONRY WALUINFILL NEW STUD WALL NEW LOW STUD WALL FLOOR PLAN GENERAL NOTES 1. CURING AND HARDENER- SEE SPECIFICATIONS FOR CURING PROCEDURE AND MATERIALS REQUIRED FOR CURING AND HARDENING OF INTERIOR AND EXTERIOR CONCRETE SLABS. 2. CONCRETE SLAB JOINTS- SEE STRUCTURAL DRAWINGS FOR TYPICAL CONCRETE SLAB JOINT LOCATIONS, REINFORCING AND DETAILS FOR THE FOLLOWING: A. ENTRY VESTIBULE B. TRUCK WELL C. SIDEWALK 3. MISCELLANEOUS WOOD BLOCKING- G.C. SHALL PROVIDE ALL NECESSARY F.R.T.WOOD BLOCKING OR METAL F.R.T. STUD BLOCKING FOR ALL WALL SUPPORTED DEVICES, I.E. ACCESSORIES, PANELS, EQUIPMENT ETC PER THE DEVICE MANUFACTURER'S RECOMMENDATIONS. 4. BUILDING SERVICES AND EQUIPMENT UTILITY DROPS- THE LOCATIONS OF ALL UTILITY DROPS INCLUDING FIRE, ELECTRICAL, PLUMBING ETC. MUST BE WITHIN 18" OF OF DOOR OPENINGS ON PERIMETER ALLS INSIDE THE BUILDING. NO LOCATIONS OF UTILITY DROPS WILL BE ACCEPTED OUTSIDE OF THESE AREAS BEFORE RACK SYSTEM INSTALLATION. 5. EXTERIOR AND INTERIOR PIPE BOLLARDS TO HAVE RED COVERS. POLYPROPYLENE COVERS BY -IDEAL SHIELD 6. THE GENERAL CONTRACTOR MUST VERIFY WITH FINAL FIXTURE PLAN BEFORE BUILDING INTERIOR PARTITIONS. FLOOR PLAN KEYED NOTES YELLOW LOADING ZONE STRIPING w/ RED NO PARKING LETTERING 60"W x 36" D x 60"H PROPANE STORAGE CAGE (BY OTHERS) 6" DIAMETER CONCRETE FILLED STEEL PIPE BOLLARD TYPICAL AT SIDES AND REAR OF BUILDING REFER TO DETAIL 3/A504 NOT USED. EXISTING STEEL COLUMN, TYPICAL - PAINT PER DETAIL 1/A800 EXISTING INTERNAL ROOF DRAIN - G.C. TO FIELD VERIFY. NEW INTERIOR DOWNSPOUT - REFER TO SHEET A301. CONCRETE PAD AT EXTERIOR DOORS NEW GAS METER LOCATION. SEE CML AND PLUMBING PLANS. 42" HIGH HANDRAIL - SEE DETAIL 2/A504 TRENCH DRAIN AT TRUCK WELL - SEE CML FOR DETAILS 12 TRANSFORMER - SEE CIVIL AND ELECTRICAL COORDINATE TRANSFORMER PAD REQUIREMENTS AND PRIMARY CONDUIT INSTALLATION WITH UTILITY PROVIDERS'S STANDARD DETAILS. 13 DOMESTIC AND FIRE RISERS - SEE CML FOR UTILITY ROUTING. PROVIDE DETECTOR CHECK VALVES PER LOCAL UTILITY REQUIREMENTS. COORDINATE SIAMESE AND PIV LOCATIONS WITH LOCAL FIRE DEPARTMENT. 14 FLUSH CURB CONDITION - SEE CML 15 6" THICK REINFORCED CUSTOMER LOAD -OUT SLAB - SEE CML AND STRUCTURAL FOR SLAB EDGE CONDITIONS AND REINFORCEMENT. 0 6" REINFORCED CONCRETE TRUCK WEU. SLAB - SEE CML AND STRUCTURAL FOR SLAB EDGE CONDITIONS AND REINFORCEMENT. 0 NOT USED. 18 COMPACTOR CHUTE AND CONTAINER BY FLOOR AND DECOR VENDOR. COORDINATE ELECTRICAL REQUIREMENTS . 0 NOT USED. 0 8" REINFORCED COMPACTOR SLAB. SEE CML FOR IDEAL SLOPE AND STRUCTURAL FOR SLAB EDGE CONDITIONS, AND REINFORCEMENT. 21 6" REINFORCED CONCRETE SLAB - SEE STRUCTURAL FOR REINFORCEMENT @ NOT USED. 0 EXTERIOR ANGLE AT LOADING DOCK WALL. 0 NEW EGRESS DOOR 1MT1-1 METAL STAIRS, RAILING AND NEW LANDING. 25 EXISTING EGRESS DOOR TO REMAIN. 0 WALL INFILL STRUCTURE. RE: STRUCTURAL & FIRE PROTECTION 0 NEW VESTIBULE/ENTRY CENTERED ON EXISTING STRUCTURAL PILASTERS AT THIS LOCATION. 1/A504 \ 3/A301 1/A503 1/A101 SEPARATE PERMIT REQUIRED FOR: 0 Mechanical I'ectrical af)lumbing Crcas ". BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED RHS DESIGN BUILD RM 144 SQFT SAKE REINDERSMA ARCHITECT 5450 E High Street, Suite 200 Scottsdale, Arizona 85054 p: 480.515.5123 f: 602.513.7193 wwwsra360.com RARCHITECTEGIS'EREJ AKE H. REINDERSMA STATE OF WASHINGTON JANITOR ABOVE 115 SQFT REVISIONS No changes shn[I be made to the scope of work t ,ith iit prior approval. of uilding Division. NCT . 14 •.s ons r ii1 require a new Flan submittal and may include additional plan review fees. COR 00 go FLbOR & DECOR 88`784 S.F. ISTING USABLE 86,337 S.F. WAREHOUSE 103 SALES 102 WOMENs 223 SQFT AREA) NOTE: REFERENCE SPECIFICATIONS SECTION 03 35 00 "POLISHED CONCRETE" FOR DESIGN MIX FILE COPY Pe it -0 ct Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: VEND. VEND. City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILIA DEC 1 5 2017 PERMIT CENTER BREAK ROOM 383 SQ CORRIDOR 2 ASSIST. ROOM DEC .24 NS 103 SQFT CITY AUG PERM CE CE KWILA VAULT 70 SQFT 141 SQFT CASH ROOM TRAINING 244 SQFT FOR PERMIT revision no.: date: job no.: 11-021 sheet title: FLOOR PLAN TENANT FLOOR PLAN SCALE: 1/16" =1F -0t1 NORTH C"--2 1 KEY PLAN SCALE: NTS A101 RTU -11 RTU -10 RTU -9 RTU - 3 RTU -8 RTU -5 RTU - 2 ROOF PLAN SCALE: 1/16" =1'-0" SLOPE 1/4" PER FT. NORTH SLOPE 1/4" PER FT. ENLARGED MAPES ROOF PLAN ac ENTRY SCALE: 1/4" =1'-0" NORTH 8/A304 0 RECOVERY BOARD WI TPO OVER METAL DECK - BY G.C. 10 PREFINISHED GUTTER AND DOWNSPOUTS, REFER TO PLUMBING. 11 EXTERIOR CANOPY UNDER SEPARATE PERMIT. COORDINATE WITH ARCHITECT. 12 GUTTER AND PIPING BY G.C., REFER TO PLUMBING. 13 60 MIL. TPO ROOF (MECHANICALLY FASTENED) MIN. R-23 AGED POLISOCYANURATE ROOF INSULATION ON 3" METAL DECK. 14 SENSOR; REFER TO M100 FOR SENSOR TYPE DETAILS. 15 PIPE ROOF DRAINS TO COLUMN LOCATIONS AND RUN DOWN COLUMN. 16 NEW ROOF DRAIN. 17 PARAPET RETURNS CANTILEVERED OFF BACK OF PANEL, REFER TO STRUCTURAL. 04 45x8' SMOKE /HEAT VENT, REFER TO 10/A202 19 PROVIDE CONTINUOUS DRIP EDGE ALONG CUTOUT IN STOLITE TOWER (3/A304). PIPE GUARD AND CONNECTIONS PER MANUFACTURE DOWNSPOUT AND STRAP WALL PER PLAN STEEL PIPE GUARD BEACON (BPGWM636-Y) AT REAR WALL, POWDER COATED YELLOW - SEE ELEVATIONS FOR LOCATIONS INSTALL PER MANUFACTURES RECOMMENDATIONS. DOWNSPOUT DOWNSPOUT AND CLEAN-OUT SEE CML FOR CONTINUATION OF DRAIN IF REQUIRED ELEVATION VIEW DOWNSPOUT DETAILS SCALE: 1/2" =1'-.0" MATCH EXISTING TIO PANEL TBD ROOF SCUTTLE TO PROVIDE PROPER DRAINAGE ROUTING AT EACH LOCATION. 6. ROOF PENETRATIONS- SEE DETAILS ON SHEET A202 FOR TYPICAL ROOF PENETRATIONS FOR ELECTRICAL, GAS AND PLUMBING PIPING. 7. FLUE AND VENT DETAILS- SEE DETAILS ON SHEET A202 FOR TYPICAL ROOF PENETRATIONS FOR FLUE AND VENT PIPE PENETRATIONS. 8. COORDINATE ROOF ELEVATIONS WITH STRUCTURAL DRAWINGS. REFER TO SPECIFICATIONS FOR ROOF WARRANTIES, CURBS, FLASHING DETAILS, ETC. 9. THE ROOF SHALL NOT BE USED FOR STOCKPILING OF EQUIPMENT OR MATERIALS UNLESS APPROVED IN WRITING BY ARCHITECT AND STRUCTURAL ENGINEER. 10. REMOVE ROOF WASTE, EMPTY ADHESIVE CONTAINERS, AND OTHER DEBRIS ON A DAILY BASIS. 11. CONDENSATE PIPING AND GAS PIPING SHALL BE SECURED TO ROOF WITH PRE - MANUFACTURED SUPPORTS WITH ADDITIONAL ROOF MEMBRANE REINFORCEMENT AT EACH SUPPORT LOCATION. NEW JOIST BEARING ZC EMBEDS, REFER TO STRUCTURAL DRAWINGS. gib 18'-0" AFF PAINT ONE / REVEAL 10'-0" AFF PAINT LINE / REVEAL NEW DOWNSPOUT NOZZLE: JOSAM #25010 -BS OR APPROVED EQUAL, AS REQUIRED RE: CML FOR DOWNSPOUT TO DAYLIGHT LOCATION. RE: PLUMBING FOR REQUIRED SIZE OF DOWNSPOUT NOZZLE IF USED 0-0" AFF FINISH FLOOR ♦, ROOF MEMBRANE OVER BONDING ADHESIVE - EXTEND UP OVER BLOCKING AT TOP OF PARAPET. CANT STRIP, SEE DETAIL 41A202 ROOF MEMBRANE OVER RIGID INSULATION (MIN. R-23) OVER STEEL DECK. REFER TO NOTES ON A201 ROOF DRAIN SUMP RE: PLUMBING STEEL JOIST, REFER TO STRUCTURAL DRAWINGS ROOF DRAIN LEADERS R •EE PLUMBING 5x5 DOWNSPOUT, PREFINISHED TO MATCH WALL. RE: PLUMBING FOR REQUIRED SIZE 71/4" CONCRETE PANEL REFER TO STRUCTURAL DRAWINGS. 5/8" FRT PLYWOOD FROM FINISH FLOOR TO 8'-0". 5/8" GYP. BD. FROM 8'-0" TO DECK. 2" RIGID INSULATION W/ METAL Z -CLIPS AT 24" STEEL DOWNSPOUT GUARD AT EACH DOWNSPOUT ATTACH W/ EXPANSION BOLTS (BEACON BPGWM636-Y) NEW BACKFILL RE: CML 3/A201 Afel 242010 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 72017 scottstfaie, Arizona s9U54 p: 480.515.5123 f: 602.513.7193 wwwsra360.com 11273 REGISTERED ARCHITECT H. REINDERSMA STATE OF WASHINGTON RECEIVED CITY OF TUKWILA DEC 1 5 2017 PERMIT CENTER NEW 6" CONCRETE SLAB, REFER TO STRUCTURAL DRAWINGS NEW FOUNDATION, FOOTING, AND BACKFILL RE: STRUCTURAL; WALL SECTION AT DOWNSPOUT SCALE: 1/2" = 11-0" OS/10/2017 issued for: FOR PERMIT revision no.:. date: job no.: 11-021 sheet title: ROOF PLAN Aug 09, 2017 — 7:08pm by Nathan 408 MLES\2017\17122 FnD Tukwila WA 71\17122 MP.dwg 4 Tips Engineering Associabas, Inc. exptesslyreserves is common law copyright & other properly rights h these plans. AB designs, Infonnaticn, data, plans, drawings and specifications are the property of Tights Engineering Associates, hha as instruments of service and may not be used for any otherImpose without written consentofTigiasEngneedn9 Associates, Inc. No liabliiy is assumed for deviations from those documents. GENERAL NOTES: A. EXISTING CONDITIONS ARE BASED ON RECORD DRAWINGS PROVIDED BY THE OWNER AND/OR LIMITED FIELD VERIFICATION BY OTHERS. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE PROJECT. B. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE PROVIDED FOR ANY EXTRAS DUE TO THE CONTRACTOR'S FAILURE TO VISIT THE PROJECT SITE PRIOR TO SUBMITTING THE BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER FOR RESOLUTION. C. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH DEMOLITION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR IS RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED FOR INSTALLATION/CONSTRUCTION OF NEW WORK. D. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES. E. MECHANICAL CONTRACTOR SHALL FIELD COORDINATE WITH ELECTRICAL CONTRACTOR FOR ALL POWER REQUIREMENTS, PRIOR TO ORDERING ANY EQUIPMENT. F. ALL CONTRACTORS SHALL REVIEW A COMPLETE SET OF CONSTRUCTION DOCUMENTS AND COOPERATE WITH THE OTHER TRADES SO THAT THE INSTALLATION OF ALL EQUIPMENT MAY BE PROPERLY COORDINATED. G. ALL EQUIPMENT FURNISHED SHALL FIT THE SPACE AVAILABLE WITH CONNECTIONS IN THE REQUIRED LOCATIONS AND WITH ADEQUATE SPACE FOR OPERATING AND SERVICING. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND INDICATE THE INTENT OF THE INSTALLATION WHILE THE SPECIFICATIONS AND EQUIPMENT LIST DENOTE THE TYPE AND QUALITY OF MATERIAL AND WORKMANSHIP TO BE USED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENTS. WHERE A CONFLICT EXISTS BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE HIGHER AND/OR MORE COSTLY STANDARD WILL APPLY. THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ENGINEER WHOSE DECISION SHALL BE FINAL. NO ALLOWANCE WILL BE MADE SUBSEQUENTLY IN THIS REGARD ON BEHALF OF THE CONTRACTOR AFTER AWARD OF THE CONTRACT. H. COORDINATE DUCT ROUTING AND HEIGHTS WITH GENERAL CONTRACTOR. VERIFY ALL CLEARANCES BEFORE STARTING WORK. I. THE CONTRACTOR SHALL INSTALL ALL PIPING, DUCTWORK AND EQUIPMENT AS REQUIRED TO CONFORM TO THE STRUCTURE, AVOID OBSTRUCTIONS, PRESERVE CEILING HEIGHTS AND HEADROOM AND MAKE ALL EQUIPMENT REQUIRING MAINTENANCE OR REPAIR ACCESSIBLE. J. ALL DUCT CONNECTIONS TO HVAC EQUIPMENT MUST BE MADE WITH FLEXIBLE CONNECTORS. K. DO NOT ATTACH ANYTHING TO DECK ABOVE. ATTACH TO STRUCTURE (I.E. BEAMS, JOISTS) ONLY. DUCT HANGERS SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE. ALL CONNECTIONS TO JOISTS SHALL BE MADE AT THE TOP CORD. COORDINATE WITH STRUCTURAL ENGINEER. ALL DUCT DIMENSIONS INDICATED ARE CLEAR INSIDE DIMENSIONS. ALL SUPPLY AND UNTEMPERED OUTDOOR AIR DUCTWORK SHALL BE LINED WITH I" ACOUSTICAL DUCT LINER OR WRAPPED WITH I -I/2" THICK FIRE RETARDANT FIBERGLASS WITH A REINFORCED ALUMINUM FOIL JACKET AND SHALL BE APPROVED FOR USE BY SMACNA AND NAIMA. RETURN AIR TRANSFER DUCTS AND RETURN DUCTWORK WITHIN 10 FEET OF THE UNIT FAN SHALL BE LINED WITH I" ACOUSTICAL DUCT LINER. M. PROVIDE REMOTE VOLUME DAMPER CONTROL MANUFACTURED BY YOUNG REGULATOR OR UNITED ENERTECH FOR DAMPERS LOCATED ABOVE INACCESSIBLE CEILINGS. LOCATE CONTROLLER ABOVE ACCESSIBLE CEILING LOCATION. N. THIS PROJECT UTILIZES A PLENUM RETURN AIR CEILING DESIGN. ALL EQUIPMENT AND MATERIALS INSTALLED IN THE PLENUM RETURN CEILINGS MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS. 0. ROOF MOUNTED EQUIPMENT SHALL BE LABELED WITH THE TENANT NAME AND SPACE NUMBER WITH 3" HIGH WEATHER PROOF LETTERS. P. MECHANICAL CONTRACTOR SHALL PROVIDE TENANT WITH A WRITTEN ONE (I) YEAR MANUFACTURER'S WARRANTY AND I YEAR LABOR WARRANTY IN ADDITION TO MANUFACTURERS WARRANTY. ON ALL HVAC EQUIPMENT PROVIDED AND / OR INSTALLED. THE WARRANTY SHALL INCLUDE ALL LABOR, MATERIALS AND THREE (3) ROUTINE SERVICES INCLUDING FILTER CHANGES DURING A ONE (I) YEAR PERIOD. Q. AT THE COMPLETION OF CONSTRUCTION AN NEBB, AABC OR TABB CERTIFIED AIR BALANCE REPORT SHALL BE SUBMITTED TO THE ENGINEER, TENANT, AND LANDLORD. THE BALANCING MUST BE COMPLETED BY AN INDEPENDENT, THIRD PARTY CONTRACTOR WITH NO TIES TO THE INSTALLING CONTRACTORS. LOADING DOCK NOTE NOTE /0 10 TON NOTE 7 (ET -3) NOTE 8 TO RTIC/2 N07E 2 NOTE 4 (RTTf-9) 2050 CFM OSA NOTE 4 2050 CFM 054 (RTU -7, RTU -8) TO RTU -7 (EF -2) TO RTU -9 NOTE Z 15 TON 15 TON NOTE NOTE IO TO RTU -8 NOTE 2 TE 3 OTE /0 NOTE /0 NOTE 7 (EF -9 RTU -13 5 TON TO RTU -I1 NOT E2 50/30 60/15 1400 CFM OSA 2050 CFN OSA NOTE 4 (R771.4, RT1.1-5) NOTE.5 NOTE /0 RTU -11 10 TON KIU-0 5 TON IU - 15 TON 2050 CFM OSA TO R7U,4 NATE 2 K1U-4 5 TON TO RTU -6 N07F 2 NOTE 3 NOTE /0 TO RTU -5 NOTE 2 0TF 3 ATE /0 NOTE 3 NOTE /0 NOTE 8 NOTE 8 /400 CFM 0S NOTE 4 (RTU -/0) 60//5 2050 CFM 084 NOTE 4 (7T11-1, R77.f2) RTU -I0 KIU ) 15 TON 2i $ .. TO RTIC/ NOTE 2 60/15 15 TON K IU—I 15 TON NOTE NOTE /0 TO RTU -/0 NOTE 2 TO RTU -5 NOTF 2 N07E 3 NOTE /0 TO RTU -2 NOTE 2 7F .5 TE /0 NOTE 3 NOTE /0 PRO SALES 0000 RTU 1-15 NOTE 1 OVERALL MECHANICAL PLAN SCALE: 1/16" = 1'-0" HVAC NOTES: I. COMMUNICATING THERMOSTAT WITH REMOTE SENSING CAPABILITIES SHALL BE FURNISHED BY ENTOUCH AND INSTALLED IN THE POWERWALL BY SQUARE D. THERMOSTATS SERVING THE SAME TEMPERATURE ZONE SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING. WIRING AND CONDUIT FROM SENSOR TO THERMOSTAT AND FROM THERMOSTAT TO ROOFTOP UNIT SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. 2. REMOTE TEMPERATURE SENSORS SHALL BE FURNISHED BY ENTOUCH AND INSTALLED BY MECHANICAL CONTRACTOR. MOUNT SENSOR ON COLUMN OR WALL AT 84" ABOVE FINISHED FLOOR. WIRING AND CONDUIT FROM SENSOR TO THERMOSTAT SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. 3. TEMPERATURE SENSOR SHALL BE FURNISHED BY ENTOUCH AND INSTALLED BY MECHANICAL CONTRACTOR. MOUNT SENSOR IN SUPPLY AIR DUCT FOR MONITORING OF DISCHARGE AIR TEMPERATURE. WIRING AND CONDUIT FROM SENSOR TO EMS SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4. CARBON DIOXIDE (CO2) SENSOR SHALL BE FURNISHED BY OWNER AS PART OF LENNOX PACKAGE TO CONTROL ROOFTOP UNIT DEMAND CONTROL VENTILATION AND SHALL BE INSTALLED BY MECHANICAL CONTRACTOR. SENSOR SHALL BE CAPABLE OF MAINTAINING A CO2 CONCENTRATION OF LESS THAN OR EQUAL TO 600 PPM_ MOUNT SENSOR AT 80" ABOVE FINISHED FLOOR. WIRING AND CONDUIT FROM SENSOR TO ROOFTOP UNIT CONTROLLER SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. 5. PROVIDE THERMOSTAT WITH UNIT HEATER. MECHANICAL CONTRACTOR SHALL INSTALL THERMOSTAT AT 84° ABOVE FINISHED FLOOR AS INDICATED ON PLAN. PROVIDE WITH INSULATED BACK FOR INSTALLATION ON EXTERIOR WALL. PROVIDE WITH LOCKING COVER. 6. MOUNT UNIT HEATER AT 14'-0" ABOVE FINISHED FLOOR. EXTEND FLUE TO ROOF FLUE VENT CAP PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. 7. PROVIDE NEW EXHAUST FAN AS NOTED ON PLANS AND SCHEDULED ON SHEET M300. THE CONTRACTOR SHALL FIELD VERIFY THAT THE LOCATION SHOWN IS A MINIMUM OF IO' -0" FROM ANY OUTDOOR AIR INTAKE. 8. PROVIDE FULL-SIZE RETURN AIR OPENING IN TOP OF DUCT WITH 3/4" MESH GALVANIZED SCREEN. EXTEND DUCT MINIMUM OF 5'-0" PRIOR TO OPENING. RETURN AIR DUCTWORK WITHIN 10'-0° OF UNIT SHALL BE LINED WITH I" ACOUSTICAL LINER. 9. NOT USED. 10. MOUNT BOTTOM OF DROP BOX DRUM LOUVER AT 18' ABOVE FINISHED FLOOR. DRUM LOUVER SHALL BE FURNISHED BY OWNER AS PART OF LENNOX PACKAGE. MECHANICAL CONTRACTOR SHALL INSTALL DRUM LOUVER AND DUCTWORK/TRANSITION BETWEEN DRUM LOUVER AND ROOFTOP UNIT. DUCT SMOKE DETECTORS SHALL NOT BE REQUIRED ON ROOFTOP UNITS SERVING THE SALES AND STOCK AREAS, PER IMC 606.2 EXCEPTION: DETECTORS SHALL NOT BE REQUIRED DISTRIBUTION SYSTEMS ARE INCAPABLE OF SPREADING SMOKE BEYOND ENCLOSED WALLS AND FLOORS. EXP M17 NORTH 3EC 24 218 115VIEVVE FOR CODE OOMMPLIANCE APPROVED DEG 7 21)17 City of Tukwila BUILDINGMLI RECEIVED CITY OF TUKWILA DEC 1 5 2017 PERMIT CENTER c ED CI : F KWIILA AUG ` 2011 Engineering Associates, Inc CO ;L1I It I' Engineers A R l 4t 19017 etc fax 512918 1 101 W. Maryland Ave. Phoeelx, AL 15113 TEA# 17122 MP SAKE REINDERSMA ARCHITECT 5450 E. HIGH STREET, SUITE 200 SCOTTSDALE, ARIZONA 85054 P: 480.515.5123 7: 602.513.7193 WWW.SRA360. COM ARCHITECT: STRUCTURAL: DATE: 8-3-2017 ISSUED FOR: PERMIT SUBMITTAL REVISION NO.: DATE: JOB NO.: 17-027 SHEET TITLE: OVERALL MECHANICAL PLAN TrelasEngineering Associates,Inc.expresslyreservesdscommonlaw copyright & other property rights In these plans. A9 designs, 'donation, data, plans, drawings and specifications are the propedy ofTiglas Erb Associates, Inc. as instruments of service and may not be used for any other purpose withoutwritten consent ofTigtasEngineering Associates, Inc. No Ilabllyy Is assumed for deviations from these doauments. EF -3 NOTE II NOTE13 NOTE4 50CFM 6/6 D-4 SIGN JANITOR 107 NOTE 4 CORRIDOR NOTE 4 /75 CFM VD /N ORGP' 75 CFM VAULT WOMENS NOTE4 105 NOTE 12 10/10 G-4 NOTE 7 275 CFM Is VD /N DROP NOTE 3 NOTE // BREAK ROOM ISSUED FOR: PERMIT SUBMITTAL REVISION NO.: DATE: 150:FM JOB NO.: 17-027 VAULT ASSIST. ROW 640411 CEM CFM CASH ROOM 113 NOTE 5 ENLARGED MECHANICAL PLAN SCALE: 1/4° = NORTH HVAC NOTES: I. REMOTE TEMPERATURE SENSOR SHALL BE FURNISHED BY ENTOUCH AND INSTALLED BY MECHANICAL CONTRACTOR. MOUNT SENSOR ON COLUMN AT 60" ABOVE FINISHED FLOOR. WIRING AND CONDUIT FROM SENSOR TO THERMOSTAT SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. 2. TEMPERATURE SENSOR SHALL BE FURNISHED BY ENTOUCH AND INSTALLED BY MECHANICAL CONTRACTOR. MOUNT SENSOR IN SUPPLY AIR DUCT FOR MONITORING OF DISCHARGE AIR TEMPERATURE. WIRING AND CONDUIT FROM SENSOR TO EMS SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. 3. PROVIDE 12/10 EXHAUST AIR DUCT UP TO EF -I ON ROOF. 4. CONTRACTOR SHALL UNDERCUT DOOR 3/4°. 5. PROVIDE FULL-SIZE RETURN AIR OPENING IN TOP OF DUCT WITH 3/4" MESH GALVANIZED SCREEN. EXTEND DUCT MINIMUM OF 5.-0' PRIOR TO OPENING. RETURN AIR DUCTWORK WITHIN I0.-0" OF UNIT SHALL BE LINED WITH I' ACOUSTICAL LINER. 6. NOT USED. 7. EXTEND WARM -AIR EXHAUST DUCT FURNISHED WITH PAC -I UNIT TO WALL GRILLE AS INDICATED ON PLANS AND PROVIDE TRANSITION AND CONNECTION AS NECESSARY. PAINT GRILLE TO MATCH WALL AS COORDINATED WITH ARCHITECT. 8. TEMPERATURE SENSOR FOR MONITORING SHALL BE FURNISHED AND INSTALLED BY ENTOUCH. 9. MECHANICAL CONTRACTOR SHALL INSTALL FLEXIBLE COOLING DUCT ACCESSORY ON UNIT PAC -I. COORDINATE COOLING DUCT TERMINATION LOCATION AND DIRECTION WITH PROJECT MANAGER. 10. PROVIDE THERMOSTAT TO CONTROL EXHAUST FAN EF -2. CONTRACTOR SHALL SET THERMOSTAT TO ENGAGE EXHAUST FAN AT 80° FAHRENHEIT OR AS DIRECTED BY THE OWNER. II. PROVIDE NEW EXHAUST FAN AS NOTED ON PLANS AND SCHEDULED ON SHEET M300. 12. PROVIDE 8/8 EXHAUST AIR DUCT UP TO EF -2 ON ROOF AND EXTEND 3" BELOW CEILING. CONTRACTOR SHALL COVER OPEN END WITH 3/4"X3/4" WIRE MESH. 13. EXHAUST FAN (EF -3) ON ROOF CURB WITH 8"X8" DUCT DOWN TO 12"X12" G2 EXHAUST GRILLE. DEC 24 201 REV'IE'W► n FOR CODE COMPLIANCE APPROVED DEC 271117 Cit of Tukwila RECEIVED CITY OF TUKWILA DEC 1 5 2017 PERMIT CENTER i1O (8 ED CITY ''\T I KW1LA AUG 17 PERMI . ENT 44x974- Engineering Associates, inc C©asalli g Mine= Fait 819W.MarylandAue. PIIestnIX AL 85013 landemiasencom TEA# 11122 MP SAKE REINDERSMA ARCHITECT 5450 E. HIGH STREET, SUITE 200 SCOTTSDALE, ARIZONA 85054 P: 480.515.5123 F: 602.513.7193 WWW.SRA360.COM ARCHITECT: STRUCTURAL: DATE: 8-3-2017 ISSUED FOR: PERMIT SUBMITTAL REVISION NO.: DATE: JOB NO.: 17-027 VAULT CASH ROOM NOTE 5 ENLARGED MECHANICAL PLAN SCALE: 1/4° = NORTH HVAC NOTES: I. REMOTE TEMPERATURE SENSOR SHALL BE FURNISHED BY ENTOUCH AND INSTALLED BY MECHANICAL CONTRACTOR. MOUNT SENSOR ON COLUMN AT 60" ABOVE FINISHED FLOOR. WIRING AND CONDUIT FROM SENSOR TO THERMOSTAT SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. 2. TEMPERATURE SENSOR SHALL BE FURNISHED BY ENTOUCH AND INSTALLED BY MECHANICAL CONTRACTOR. MOUNT SENSOR IN SUPPLY AIR DUCT FOR MONITORING OF DISCHARGE AIR TEMPERATURE. WIRING AND CONDUIT FROM SENSOR TO EMS SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. 3. PROVIDE 12/10 EXHAUST AIR DUCT UP TO EF -I ON ROOF. 4. CONTRACTOR SHALL UNDERCUT DOOR 3/4°. 5. PROVIDE FULL-SIZE RETURN AIR OPENING IN TOP OF DUCT WITH 3/4" MESH GALVANIZED SCREEN. EXTEND DUCT MINIMUM OF 5.-0' PRIOR TO OPENING. RETURN AIR DUCTWORK WITHIN I0.-0" OF UNIT SHALL BE LINED WITH I' ACOUSTICAL LINER. 6. NOT USED. 7. EXTEND WARM -AIR EXHAUST DUCT FURNISHED WITH PAC -I UNIT TO WALL GRILLE AS INDICATED ON PLANS AND PROVIDE TRANSITION AND CONNECTION AS NECESSARY. PAINT GRILLE TO MATCH WALL AS COORDINATED WITH ARCHITECT. 8. TEMPERATURE SENSOR FOR MONITORING SHALL BE FURNISHED AND INSTALLED BY ENTOUCH. 9. MECHANICAL CONTRACTOR SHALL INSTALL FLEXIBLE COOLING DUCT ACCESSORY ON UNIT PAC -I. COORDINATE COOLING DUCT TERMINATION LOCATION AND DIRECTION WITH PROJECT MANAGER. 10. PROVIDE THERMOSTAT TO CONTROL EXHAUST FAN EF -2. CONTRACTOR SHALL SET THERMOSTAT TO ENGAGE EXHAUST FAN AT 80° FAHRENHEIT OR AS DIRECTED BY THE OWNER. II. PROVIDE NEW EXHAUST FAN AS NOTED ON PLANS AND SCHEDULED ON SHEET M300. 12. PROVIDE 8/8 EXHAUST AIR DUCT UP TO EF -2 ON ROOF AND EXTEND 3" BELOW CEILING. CONTRACTOR SHALL COVER OPEN END WITH 3/4"X3/4" WIRE MESH. 13. EXHAUST FAN (EF -3) ON ROOF CURB WITH 8"X8" DUCT DOWN TO 12"X12" G2 EXHAUST GRILLE. DEC 24 201 REV'IE'W► n FOR CODE COMPLIANCE APPROVED DEC 271117 Cit of Tukwila RECEIVED CITY OF TUKWILA DEC 1 5 2017 PERMIT CENTER i1O (8 ED CITY ''\T I KW1LA AUG 17 PERMI . ENT 44x974- Engineering Associates, inc C©asalli g Mine= Fait 819W.MarylandAue. PIIestnIX AL 85013 landemiasencom TEA# 11122 MP SAKE REINDERSMA ARCHITECT 5450 E. HIGH STREET, SUITE 200 SCOTTSDALE, ARIZONA 85054 P: 480.515.5123 F: 602.513.7193 WWW.SRA360.COM ARCHITECT: STRUCTURAL: DATE: 8-3-2017 ISSUED FOR: PERMIT SUBMITTAL REVISION NO.: DATE: JOB NO.: 17-027 SHEET TITLE: ENLARGED MECHANICAL PLAN Tglas Engineering Associates, Inc. expressly Reserves is common taw copyright & other property rights bi these piens. M damns, informalion, data, plans, drawings and specifications are the property ofllglas Engineering Associates, Inc. as instruments of svica and may not be . used for any other purpose %Clout%rtten=sent ofTlglaBEngineering Associates, Inc. No Wily is assumed IordevtaVons from these documents. OUTSIDE AIR CALCULATIONS (CODE: 2015 INTERNATIONAL MECHANICAL CODE) OCCUPANCY CATEGORY FLOOR AREA Az (FT2) AREA OUTDOOR AIRFLOW RATE RA (CFM/FT2) PEOPLE OUTDOOR AIRFLOW RATE RP (CFM/P) OCCUPANT DENSITY (#/IOOOFT2; OUTDOOR AIRFLOW VBz (CFM) CORRECTED OUTDOOR AIRFLOW VOZ (CFM) EXHAUST RATE (CFM/FT2) REQUIRED EXHAUST AIRFLOW (CFM) RETAIL 68066 15825 19782 SHIPPING/RECEIVING 17876 2503 3128 JANITOR CORRIDOR STORAGE BREAK ROOM TRAINING ROOM OFFICE SPACE VAULT/DEPOSIT PUBLIC TOILETS GAS LINE 75 PER FIXTURE 225 PUBLIC TOILETS 75 PER FIXTURE 225 12.0 -RS- REFRIGERANT SUCTION UNE RTU -6 SQUARE CEILING DIFFUSER TWO WAY THROW TOTAL OUTDOOR AIR REQUIRED 23281 TOTAL EXHAUST REQUIRED /3-1/4" OUTSIDE DIMENSION - SYMBOL INSIDE DIMENSION SYMBOL DESCRIPTION 24", 201 /8" OR /2° C" CHANNEL REINFORCING BY G.C. AROUND OPENING MOUNTING SCREW FIELD INSTALLED DRYWALL CEILING I-1/2" /--//8" STEEL MOUNTING FRAME NOTE f. CONTACT MANUFACTURERFOR /NFORMAT7ONREGARDING ROUGH-INS/ZES. TYPICAL DRYWALL MOUNTING FRAME DETAIL NOT TO SCALE MECHANICAL CONTRACTOR NOTES: I. MECHANICAL CONTRACTOR SHALL COMPLETE EQUIPMENT STARTUP CHECKLIST. REFER TO CONSTRUCTION SPECIFICATION 23740. 2. MC SHALL INCLUDE IN HIS BASE BID ALL COSTS ASSOCIATED WITH PROVIDING A HEATING AND COOLING STARTUP. 3. HEATING STARTUP: STARTUP TO BE CONDUCTED ANYTIME OF THE CALENDAR YEAR. MC SHALL VERIFY PROPER OPERATION OF ALL HEATING EQUIPMENT. 4. MC SHALL: CLEAN ALL EQUIPMENT, ENSURE GAS PRESSURE IS CORRECT AT EACH PIECE OF EQUIPMENT, REPLACE AND ADJUST BELTS AS REQUIRED, REPLACE DISPOSABLE FILTERS AND CLEAN OUTSIDE AIR INTAKE FILTERS AT JOB TURNOVER AND AT GRAND OPENING. 5. COOLING STARTUP: STARTUP TO BE CONDUCTED WHEN AMBIENT CONDITIONS ALLOW. MC SHALL VERIFY PROPER OPERATION OF ALL COOLING EQUIPMENT. 6. MC SHALL: CLEAN ALL EQUIPMENT, ENSURE ALL VOLTAGE IS CORRECT AT EACH PIECE OF EQUIPMENT, REPLACE AND. ADJUST BELTS AS REQUIRED, REPLACE DISPOSABLE AIR FILTERS WITH MERV 8 PLEATED FILTERS AND CLEAN OUTSIDE AIR INTAKE FILTERS AT JOB TURNOVER AND AT GRAND OPENING, VERIFY REFRIGERANT LEVELS ARE CORRECT AND REPLENISH IF NECESSARY. 7. MC TO PROVIDE TEMP PROTECTION ON RETURN AIR FILTERS DURING CONSTRUCTION. SYM B O LS HEATING -VENTILATING -AIR CONDITIONING • SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION fi` STEAM (MEDT PRESSURE)STEAM (LOW PRESSURE) STEAM (HIGH PRESSURE) AAUTOMATIC CONTROL VALVE t,, SUPPLY DUCT (SA) // // -(433-..PRESSURE REGU.ATING VALVE (PRV) SAFEIY RELIEF VALVEF TWO 8 GA. El OR EXHAUST OR AUR DUC OR FA)• CONDENSATE (LOW PRESSURE) CONDENSATE (EDIU M PRESSURE) CONDENSATE (HIGHGH PRESS& ) "RETURN BLOW OFF VALVE ))FRESH SOUND TRAP -IRIS- HOT WATER SUPPLY (HEATING) TWO 3/8" AND T TRAP (CAP. S/NIR) HOT WATER RETURN (HEATING) TWO 1/2" SUPPLY REGISTER OR GRILLE (R OR G) THERMOSTATIC TRAP ETHYLENE GLYCOL SUPPLY STATIC PRESSURE REfLRH REGISTER OR GRILLE (R CR G) - ES- ETHYLENE GLYCOL RETURN 0.5 CIRCUIT SETTER FLOW CONTROL VALVE SIZE -CWS- CHILLED WATER SUPPLY (1 - AIR BLEEDER VALVE (RADIANT PAWL) CFNI rSIZEFRESH AIR INTAKE (FA) -ast- CHILLED WATER RETURN S AIR EUMINATOR f ROUND CEILING DIFFUSER (SUPPLY) y„ _ CONDENSATE OR VACUUM 6,000 AUTOMATIC BALANCING VALVE j . 8 460 Alm DISCHARGE HUMIDIFICATION LINE --(1,)--- \\\l ROUND CEILING DIFFUSER (SUPPLY AND RETURN) ----H-- r --0-,-.-- SOLENOID VALVE (REFRIGERANT) S ( -AGS- TLE(. OIL SUPPLY '® .. THERMOSTATIC EXPANSION VALVE(REAR) ( ` v (SUPPLY) CEILING DIFFUSER --Far- FUEL OR RETURN 5.0 S aL_ BACK PRESSURE VALVE /7 -FOV- FIIEL OIL VENT -.(D- SIGHT GLASS ` SQUARE CEILING DIFFUSER (SUPPLY Atm RETURN) - G- GAS LINE 2050 260 208 REFRIGERANT LIQUID UNE 0.5 PIPE OR ROUND DUCT RISER- --7SQUARE 'f CEILING DIFFUSER THREE WAY THROW -RL- [J FC -1" FAN COL UNIT AND MARK 12.0 -RS- REFRIGERANT SUCTION UNE RTU -6 SQUARE CEILING DIFFUSER TWO WAY THROW -R5 REFRIGERANT HOT GAS DISCHARGE LINEutir 2050 UeT HEATER -PROPELLER TYPE 8 KWIC 208 6,000 '+., `+,[ AUTOMATIC DAMPER CONDENSER WATER -C- t , - CABINET W17 HEATER a MARK 2420 12.0 WATER RETURN ...104WV\-.. _ GRAVITY DAMPER --CR--CONDENSER -830 - BOILER SLOW OFF FT -I r , I H FIN TUBE, MARK Arm CAPADTY FR D FIRE DAMPER .....ES..........EXHAUST STEAM 460 CONVECTOR AND MARK 42 45 --•••111F- CONCENTRIC REDUCER © UNIT VENTILATOR AND MARK I BD BASEBOARD DIFFUSER HEATING RISER NUMBER 182.1 ECCENTRIC REDUCER }- ( '§§" ( RECTANGULAR DICT FIRST FIGURE IS SIDE SHOW! ROW DUCT: C --COLD R=RETURN1.1410T S.-UPPLY 208 WIDE ICE , -111-- , b 0 ...-1191 STRAINER 1 f1} CANVAS CONNECTION LGHI80H4M [1-11,13-21] EXHAUST FAN RISER NUMBER 138.4 182.1 O -rr EXPANSION JOINT gilitrIV VOLUME DAMPER ED EV AND PLAN) eit atssa RD RADIATION IQf -- THERMOSTATki $ TURN/VANES a REMOTE SENSOR R4IOA THERMOMETER RTU -I0 89.6 124.4 10 PRESSURE GAGE 93:3EXTRACTOR 144 NOTE: I. NOT EVERY SYMBOL ON THIS SCHEDULE APPEARS ON THIS PROJECT. UPPER HANGER ROD HANGER BOX LEVEL ADJUSTMENT NUT LOWER HANGER ROD SPRING HANGER ASHRAE TYPE 3 NOT TO SCALE DIA. WIRE DIA. ROD STRAP 10" DN ONE 12 GA. 1/4" I" x 22 GA. 11-18" TWO 12 GA. OR ONE 8 GA. 1/4" 1" x 22 GA. 19-24" TWO 10 GA. 1/4" 1" x 22 GA. 25-36' TWO 8 GA. 3/8" I" x 20 GA. 37-50" - TWO 3/8" TWO I" x 20 GA. 51-60" - TWO 3/8" TWO I' x 18 GA. 61-84" - TWO 3/8" TWO I" x 16 GA. 85-96° - TWO 1/2" TWO 11/2" x 16 GA. NOTES: I. STRAPS ARE GALVANIZED STEEL; RODS ARE UNCOATED OR GALVANIZED STEEL; WIRE IS BLACK ANNEALED, BRIGHT BASIC OR GALVANIZED STEEL. ALL ARE ALTERNATIVES. 2. TABLE ALLOWS FOR CONVENTIONAL WALL THICKNESS, AND JOINT SYSTEMS PLUS ONE LB/SF OF INSULATION WEIGHT. IF HEAVIER DUCTS ARE TO BE INSTALLED, ADJUST HANGER SIZES TO BE WITHIN THEIR LOAD LIMITS. ROUND DUCT HANGER TABLE NOT TO SCALE ROOF TOP UNITS (FURNISHED BY OWNER) MARK CLG. CAP. (MBH) OSA CFM HTG CAP. (MBH) CFM EXT. S.P. FAN HP ELECTRICAL WEIGHT (LBS) SEER/ EER REF. TYPE LENNOX MODEL NUMBER SENS. TOTAL NOM TONS INPUT OUTPUT VOLTS PH MCA MOCP RTU -I 138.4 182.1 15.0 2050 260 208 6,000 0.5 5.0 460 3 42 45 2420 12.0 R4IOA LGHI80H4M [1-11,13-21] RTU -2 138.4 182.1 15.0 2050 260 208 6,000 0.5 5.0 460 3 42 45 2420 12.0 R4IOA LGHI80H4M [1-11,13-21] RTU -3 138.4 182.1 15.0 2050 260 208 6,000 0.5 5.0 460 3 42 45 2420 12.0 R4IOA LGHI80H4M [1-11,13-21] RTU -4 138.4 182.1 15.0 2050 260 208 6,000 0.5 5.0 460 3 42 45 2420 12.0 R4104 LGHI80H4M [1-11,13-21] RTU -5 138.4 182.1 15.0 2050 260 208 6,000 0.5 5.0 460 3 42 45 2420 12.0 R4I0A LGHI80H4M [1-11,13-21] RTU -6 138.4 182.1 15.0 2050 260 208 6,000 0.5 5.0 460 3 42 45 2420 12.0 R4IOA LGHI80H4M [1-11,13-21] RTU -7 138.4 182.1 15.0 2050 260 208 6,000 0.5 5.0 460 3 42 45 2420 12.0 R4IOA LGHI80H4M [1-11,13-21] RTU -8 138.4 182.1 15.0 2050 260 208 6,000 0.5 5.0 460 3 42 45 2420 12.0 R4IOA LGHI80H4M [1-11,13-21] RTU -9 138.4 182.1 15.0 2050 260 208 6,000 0.5 5.0 460 3 42 45 2420 12.0 R4IOA LGH180H4M [1-11,13-21] RTU -I0 89.6 124.4 10.0 1400 180 144 4,000 0.5 3.0 460 3 26.0 30 1450 12.0 R4104 LGHI20H4M [1-11,13-21] RTU -II 89.6 124.4 10.0 1400 180 144 4,000 0.5 3.0 460 3 26.0 30 1450 12.0 R4IOA LGHI20H4M [1-11,13-21] RTU -12 89.6 124.4 10.0 1400 180 144 4,000 0.5 3.0 460 3 26.0 30 1450 12.0 R410A LGHI20H4M [1-11,13-21] RTU -13 46.8 63.3 5.0 650 108 86 2,000 0.5 1.0 460 3 17.0 20 975 12.7 R4104 LGH060H4E [1-9,12,14-21] 1. COOLING CAPACITIES BASED ON ARI STANDARD 210/240 OR 340/360: 80° F DB/ 67° F WB INDOOR ENTERING AIR TEMPERATURE, 85° F DB AIR ENTERING OUTDOOR FAN. SCHEDULED UNIT CFM MAY DIFFER FROM ARI STANDARD CFM. 2. LENNOX IS THE BASE OF DESIGN. ROOFTOP UNITS ARE FURNISHED BY OWNER AND INSTALLED BY MECHANICAL CONTRACTOR. COORDINATE CURB LOCATION AND INSTALLATION WITH STRUCTURAL ENGINEER. COORDINATE ROOF PENETRATIONS WITH LANDLORD APPROVED ROOFING CONTRACTOR. 3. (FBO) ENTOUCH EMS CONTROL WITH COMMUNICATING THERMOSTAT, WITH SUPPLY AND RETURN AIR SENSORS (2 HEATING AND 3 COOLING STAGES MIN.). REFER TO ADDITIONAL CONTROL NOTES THIS SHEET. 4. SUPPLY FAN SHALL OPERATE CONTINUOUSLY DURING OCCUPIED HOURS. 5. PROVIDE WITH FACTORY INSTALLED DISCONNECT, POWERED CONVENIENCE OUTLET AND THROUGH THE BASE ELECTRICAL CONNECTION. 6. PROVIDE WITH 14" HEIGHT ROOF CURB, COORDINATE WITH STRUCTURAL DRAWINGS FOR LOCATION, ADAPTOR CONNECTION, ETC. 7. PROVIDE WITH DIFFERENTIAL ENTHALPY ECONOMIZER AND BAROMETRIC RELIEF DAMPER. 8. PROVIDE WATER LEVEL MONITORING DEVICE IN DRAIN PAN TO SHUT OFF UNIT IF THE DRAIN LINE BECOMES RESTRICTED. 9. PROVIDE WITH CONDENSER COIL HAIL GUARD. 10. PROVIDE DEMAND CONTROL VENTILATION AND CO2 SENSOR (SENSORS PER PLAN). II. UNITS WITH COOLING CAPACITY GREATER THAN 65 MBH SHALL HAVE MULTI -STAGE CAPABILITY PER APPLICABLE ENERGY CODE. 12. PROVIDE WITH FACTORY INSTALLED RETURN DUCT SMOKE DETECTOR, EXCEPT AT SALES AND STOCK AREAS PER IMC 606.2 EXCEPTION. 13. PROVIDE WITH DROP BOX DRUM LOUVER (PART OF LENNOX PACKAGE). 14. COORDINATE WITH EQUIPMENT SUPPLIER FOR ALL FIELD INSTALLED ACCESSORY REQUIREMENTS. 15. PROVIDE WITH RTU TO CURB HOLD DOWN CLIPS AND CORROSION PROTECTION - PHENOLIC EPDXY COATING, FACTORY APPLIED TO CONDENSER AND EVA PORATOR COILS, FOR LOCATIONS WITHIN 10 MILES OF SALTWATER BODIES AND FOR ALL OF FLORIDA. 16. ALL DOORS NEED TO BE ACCESSIBLE AND ALLOWED TO FULLY OPEN. 17. CONTRACTOR TO PROVIDE I -YEAR WARRANTY FOR WORK IN ADDITION TO FACTORY WARRANTY. 18. VERIFY WITH ELECTRICAL ENGINEER PRIOR TO ORDERING EQUIPMENT. 19. PROVIDE FACTORY INSTALLED STAINLESS STEEL HEAT EXCHANGER. 20. PROVIDE ENVIRONMENTAL CORROSION PROTECTION FOR CONDENSER COILS. 21. PROVIDE HUMIDITROL DEHUMIDIFICATION SYSTEM. EXHAUST FANS (FURNISHED BY G.C.) MARK LOCATION SERVICE CFM EXT. S.P. (IN W.G.) SONES MOTOR DATA RPM MFR. REMARKS HP VOLTS PH CYC. EF -I ROOF RESTROOMS 600 0.5 9.4 1/4 115 I 60 1725 GREENHECK G -098-A [1-4] EF -2 ROOF I.T. 330 0.5 6.6 1/15 115 1 60 1550 GREENHECK G -090-D [I-4] EF -3 ROOF CUT ROOM 150 0.25 4.3 1/30 115 I 60 1550 GREENHECK G-065-D[I-4] GREENHECK IS THE BASE OF DESIGN. COOK, PENN AND CAPTIVEAIRE ARE EQUAL. NO EXCEPTIONS. 2. PROVIDE SOLID STATE SPEED CONTROL. 3. PROVIDE MOTORIZED BACKDRAFT DAMPER. 4. PROVIDE MINIMUM 12" HEIGHT ROOF CURB. 5. CONTRACTOR TO PROVIDE I -YEAR WARRANTY FOR WORK IN ADDITION TO FACTORY WARRANTY. UNIT HEATERS (FURNISHED BY G.C.) MARK SERVICE INPUT MBH OUTPUT MBH TEMP. RISE °F CFM MOTOR DATA RPM MANUFACTURER MODEL NUMBER HP VOLTS PH UH -I RECEIVING 175 145 60 2242 1/6 115 I 1050 REZNOR UDAP-175 [1-3] UH -2 PRO -SALES 175 145 60 2242 1/6 115 I 1050 REZNOR UDAP-175 [1-3] I. PROVIDE WALL -MOUNTED THERMOSTAT WITH LOCKING COVER. 2. PROVIDE HANGER KIT. 3. PROVIDE ROOF CONCENTRIC VENT KIT. 4. CONTRACTOR TO PROVIDE I -YEAR WARRANTY FOR WORK IN ADDITION TO FACTORY WARRANTY. PORTABLE SELF-CONTAINED AIR CONDITIONING UNIT (FURNISHED BY G.C.) MARK COOLING CAP. (MBH) HEAT CAP. (MBH) CFM EXT. SP (IN H20) FAN HP ELECTRICAL REF. TYPE TRIPP LITE MODEL NUMBER TOTAL SENSIBLE VOLTS PH MCA MOCP PAC -1 12,000 -- N/A 329 0.0 -- 120 1 12.0 15 R4104 SRCOOLI2K I. TRIPP LITE IS THE BASE OF DESIGN. 2. UNIT PLUGS INTO STANDARD 15 AMP OUTLET (NEMA 5-15R). 3. UNIT TO RESTART AUTOMATICALLY AFTER POWER FAILURE. 4. PROVIDE WITH COLD AIR DIRECTIONAL TUBE AND HOT EXHAUST AIR REMOVAL TUBE. 5. CONTRACTOR TO PROVIDE I -YEAR WARRANTY FOR WORK iN ADDITION TO FACTORY WARRANTY. DIFFUSERS, GRILLES AND REGISTERS (FURNISHED BY G.C.) MARK SERVICE LOCATION CLG. TYPE MANUFAC. CATALOG NUMBER REMARKS D -I SUPPLY CEILING AC TILE TITUS TMSA X 24x24 3 26 D-75 SEE PLAN FOR NECK SIZE [1,4.5] D-2 SUPPLY CEILING GYP BD TITUS TMSA X 12x12 3 26 D-75 SEE PLAN FOR NECK SIZE [1,3-5] D-3 SUPPLY CEILING GYP BD TITUS TMSA X 24x24 3 26 D-75 SEE PLAN FOR NECK SIZE [1,3-5] D-4 SUPPLY WALL N/A TITUS 300RL X X 1 26 SEE PLAN FOR NECK SIZE [I] G -I RETURN CEILING AC TILE TITUS 50F X X 3 26 SEE PLAN FOR NECK SIZE [1,2,4] G-2 RETURN/EXHAUST CEILING GYP BD TITUS50F X X 126 SEE PLAN FOR NECK SIZE [1-4] G-3 EXHAUST WALL N/A TITUS 350FL X X 126 SEE PLAN FOR NECK SIZE [i] *G-4 EXHAUST WALL N/A TITUS 350RL X X 126 SEE PLAN FOR NECK SIZE [I] 1. TITUS IS BASE OF DESIGN. KREUGER, PRICE, CARNES ARE EQUAL. NO EXCEPTIONS. 2. PROVIDE 1/2° x 1/2' x I" CORE. 3. PROVIDE MODEL TRM FRAME. 4. REFER TO REFLECTED CEILING PLAN FOR EXACT LOCATION. 5. PROVIDE WITH 4 -WAY THROW PATTERN UNLESS OTHERWISE INDICATED ON PLAN (ARROWS). DRUM LOUVER PLENUM DIFFUSER (FURNISHED BY OWNER) MARK SERVICE LOCATION CLG. TYPE MANUFAC. CATALOG NUMBER REMARKS DD -I 4 -WAY SUPPLY - DUCT N/A CURBS PLUS, INC. DLPD-2510-15 (6000 CFM) [I] DD -2 4 -WAY SUPPLY DUCT N/A CURBS PLUS, INC. DLPD-2010-10/12.5 4000 CFM) [I] I. FURNISHED BY OWNER AS PART OF LENNOX PACKAGE. ALL ROOF WORK SHALL BE PERFORMED BY LANDLORD APPROVED ROOFING CONTRACTOR. GC TO FURNISH 1 YEAR LABOR WARRANTY FOR WORK IN ADDITION TO EQUIPMENT MANUFACTURER WARRANTY. LENNOX NATIONAL ACCOUNT CONTACT: HOMER UEHLINGER, HOMER.UEHLINGER@LENNOXIND.COM DEC 242O18 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 7 2017 City of Tukwila BUILD1N L1SI©N CITY OF TUKWILA DEC 1 5 2017 PERMIT CENTER ECE EI CI ' : F F : KWILA A ; 2017 PERM C ER F q9 4P 9'W17' /1-•.. Ofr , giasFIX 6 ' 1541 ten 199 W.1181011ARI. 141880. AL 85113 Engineering Associates, Inc ,` ' IA# inn p ensuing minim SAKE REINDERSMA ARCHITECT 5450 E. HIGH STREET, SUITE 200 SCOTTSDALE, ARIZONA 85054 P: 480.515.5123 F: 602.513.7193 Www.SRA36O.COM . ARCHITECT: STRUCTURAL: 5 1- 1- z 0 u O NEV,) 00§ oug era . 411 >- cL o V~Q Q w c:e'S < ct ocD `0 LL J L. >- W DATE: 8-3-2017 ISSUED FOR: PERMIT SUBMITTAL REVISION NO.: DATE: JOB NO.: 17-027 SHEET TITLE: MECHANICAL SPECIFICATIONS HEET NO.: M300 FILES\2017\17122 FMD Tukwaa WA 71\17122 MP.dwg Aug 09, 2017 — 7:08pm by Nathan ADJUSTABLE OR SOLID SHEET METAL RAD/GS ELBOW, MIN INSIDE RADIUS TO BE /X D/A SHEETMETAL SCREWS (MIN OF4) RADIUS ELBOW NOT TO SCALE INSULATED FLEX DUCT (5'-O MAX) MARE TO ROUND TRANSIT/ONPER SMACNA RETURN GRILLE PER FLOOR PLANS /'ACOUST/CAL Lilt/NG; BLACK FACE —1 RETURN AIR GRILLE SHEET METAL PLEMN,, FILL SIZE OFRETL4?N GRILLE 11 NOT TO SCALE Tiglas Engineering Associates, Inc. expressly reserves its common Law copyright 8 other properly rights in these plans. Ali designs, information, data, plans, drawings and specifications are the property of Tigles &peering Associates. Inc. as instruments of service and may not be used for any other purpose wdtrootwritten consentofTiglas EnOneering Associates, Mc. No llabilly is ass urred for deviations from these documents. i i i 2'SHEETMETAL HANGER STRAP AIR TITE TAKEOFF SLEEVE INSULATION 26 GAGE G.1. FLASHING WITH SHEET METAL SCREWS METALBESTOS OR EQUAL DOUBLE-WALL VENT PANOU/T STRAP ON INTERIOR 8 EXTERIOR OF /NSIL4TED r J FLEX DICT FLEXIBLE DUCT TAKEOFF NOT TO SCALE ROOF CAP, METALBESTOS OR EQUAL STORM COLLAR S/NGLEWALL FLEE CONNECTION SEALED WITH ACCEPTABLE MATER/AL NOTES: 1 PROVIDE 2' CLEAR DIAMETER FROM ALL COMBUST/BLE SURFACES. Z CAP, JACK 8 COLLAR SECLL,ED WITH 4 METAL SCREWS. 3. ALL PARTS TO BE BY THE SAMEMANVFACTMRER. 4. FLLEPENETRATION OF ROOF SHALL BEA MIN/MIN OF 10=0' FROM PARAPET. TOP OF ROOF CAP SHALL TERMINATE IV' ABOVEROOF SLRFACE. 5. ALL GAS FLIES TO BE TYPE 73'METALBESTOS OR EQUAL. TERM/NATERif ABOVE /N ACCORDANCE M77/ CODES. PROVIDE ROOF JACK, WAIERPROOFAT ROOF 8 FLUE SEE ARCH/TECTUR4L DRAW/NGS FOR DETAIL. HEATER FLUE ROOF PENETRATION NOT TO SCALE BAR JO/ST WRAP /NSLLATION SQUARE TO ROUND CENTER SPREAD SHEETMETAL SCREWS— — SLEEVE /NSLL4T/ON SQUARE TO ROUND TRANSITION NOT TO SCALE MINIMUM 6' WIDE, /8 GAUGE GALVANIZED STEEL HOLD-DOWN, MECHANICAL CONTRACTOR TO PROV/DEA M/NOF (2)HOLD-DOWNS ON LONG SLOES OF UNIT 8 (II ON SHORT SIDES OF LdY/T (4) #IOX//2' TEX SCREWS TO ATTACHHULD-DOWN TO CMB NAILER STR/P // i IMPORTANT- HOLD-DOW MPORTANTHOLD-DOWN MUST BE INSTALLED TO CURB PR/OR TO RR/ BEING SET ON CURB (4) #10X1/2' TE/( SCREWS TO ATTACH HOLD-DOWN TO LWIT RAILS ROOF CLRB i / . RIGID /NSLLAT/ONBY CC '///, ///%/ DECK REFER TO STRUCTURAL DRAW/NGS FOR S7RUCTTRAL SUPPORT DETAILS RTU -TO -CURB HOLD-DOWN NOT TO SCALE SQUARE ELBOW NOT TO SCALE NOT TO SCALE TYPICAL OFF/CEPACK4GE LWIT B-LINEB24 STRUT BOLTED TO BAR JOIST TRANSITION AS SHOWN ONDWGS SUPPLY RETURN ROOF v v _ FLEX/BLE CONNECTION SUPPORT FROM STRUCTURE AS /REQUIRED BY SMACNA TYPICAL INSULATED DUCTWORK (TYPFOR SUPLY8 RETURN) CEILING ODTYPICAL DUCT AT OFFICE AREA NOT TO SCALE NOT TO SCALE ELECTRICAL CONDUIT GUIDE WOOD NAILING STRIP PREFABRICATED ROOF CCM INSTALLED SIPPLYAIR PLENUM/TRANS/TION IS PROVIDED BY THEMECHNV/CAL CONTRACTOR, LENGTH OF NIS DUCT DEPENDS ONDEP7H OF STRUC77JRAL STEEL. SIZE OF EXTENSION DEPENDS ONS/ZEOF SUPPLY AIR DROP BOX DUCT OPENING, VERIFYD/MENSIONSFROM BOX BOLT (Z) B -LINE 624 STRUTS ON BOTTOM CHORD OF BAR JOISTS SUPPORT SLFPLYDROP BOX FT20MSTRUT 18'-0' AFF SHEETMETAL SCREW SADDLE OR T FITTING SLEEVE INSULATION BRANCH DUCT SHEETMETAL SCR RETURN TAKEOFF 45° TAKEOFF SLEEVE INSULATION DUCT DROP ATTACH DUCT TO LWIT WITH FLEXIBLE CONNECT/ON INSULATED DUCTWORK (TY? FOR SUPPLY 8 RETIRN) _ oveseppQlam BRANCH DUCT SUPPLY TAKEOFF BRANCH TAKE -OFF ROUND NOT TO SCALE MECHANICAL UNLIT TO BESET LEVEL, CONTRACTOR TO RESTRAIN LW/T PER MANI #ACT IRER S RECOMMENDATIONS TAP SEALANT • CONTINUOUS GALVANIZED METAL FLASHING FACTORYFLRW/SHED ROOF CURB TO OFFSET ROOF SLOPE 47//; DECK /Jf- OFFICE RTU MOUNTING NOT TO SCALE RTU-# A/R T/TE TAKEOFF SLEEVE INSULATION BRANCH DUCT (ROUND) BRANCH TAKE -OFF RECTANGLE NOT TO SCALE SHEET METAL PLANUM, RILL SIZE OF RETURN GRILLE /'ACOUSTICAL LINING, BLACK FACE CONICAL SPIN -IN — STENC/L ROOFTOP UNIT WITH RTU-`; 12' RED, VISIBLE FROMBUILD/NGROOF HATCH 5' MIN 0 e STENCIL ROOFTOP GMT ,# TO — BOTTOM OFDROP BOX (8' RED) MOTOR NOISING .S -i: x.110 111,1 111:0:.ir{{1X0: a01X}i... .1.ri.s..YY,,x:.,.-,Y.f...ryivt{.yi%:h>.n11'••_ 0 0 CURB CAP ROOFING MEMBRANE INSULATION ROOFDECK RIGID CONDUIT TO ACCOMMODATE — ELECTRICAL WRING (SEE NOTES) GRAVITY BACKDRAFT DAMPER NOTES- 1 OTES1 SECIRE CLRB CAP TO WOOD NA/UNG STRIP WITH #/0XI/2' TEN SCREWS AT /2'O.C. 2. SECLREDICTWORK 8 DAMPER TO ROOF WITH RUST RESISTANT BOLTS. J. SIZEOFDUCT THROUGH ROOF SHALL NOT BELARGER 77/AN C(RB SUPPLIED WITH EXHAUST FAN. 4. REFER TO ARCHITECTURAL SRAW/NGS FOR ROOF [LASHING DETAILS. EXHAUST FAN NOT TO SCALE ,1 v.?:Prn 1:,..0. 111:,:40111 RIR BOLT THRU SUPPORT TABS ONBOXAT EACH CORNER PROVIDE PLASTIC BUSHED NUT S(.PPLYDIFFUSERDROP BOX (CURB FLUS)TO BE PROVIDED BYLENNOX (RIO). ROTATEOMR LOUVERS SO THAT THE BOTTOM EXE OF THE AWN LOUVER OPENING /S FLUSH WITH THE BOTTOM EDGE OF THE ORM INSIL4TED CLASS I FLEX DUCT (5'-0' MAX) A/R DEVICE PER FLOOR PLANS REDUCED HEIGHT RETURN GRILLE NOT TO SCALE NOTES: /. DRLMLOUVER 8 BOX IN WHICH THEY ARE MOUNTED, ISA FRE -FABRICATED ICU/T 8 /SNOT TO BEF/ELDFABRICATED. 2. PROVIDE LOCK WASHER AT ALL BOLTED CONNECT/DNS. 3. DRU'/LOUVER TO BE SIZED TO MATCH RTU IMAGE 8 A/R FLOW. COVER OPENING W/IN 3/4' MESH GALVANIZED SCREEN — -- SALES/RECEIVING RTU DUCT DROP INSULATED RETLR'NA/R DUCTWORK NOT TO SCALE 4 FT MIN. FROM WALL ADJOINING BUILD/NG ISOLATE FLUE THRU ROOF FROM STRUCTURE IN ACCORDANCE WITH LOCAL CODES AND NEPA REQUIREMENTS SECURE MOUNTING ANGELS TO JOISTS • GAS FIRED UNIT HEATER SEE SCHEDULE SUPPORT WIT HEATER FROM ROOF STRUCTURE AS REQUIRED BY UNIT MANUFACTURER PROVIDE GAS COCK, UNION, AND DIRT LEG VENT (FLUE EXHAUST) TERM/NAL COMBUSTION AIR TY INLETS ROOF MEMBRANE INSULATION ROOF DECK JOIST • 0.111 r`'.;+•+ ,/' , / "' 9-3/8' NOTE WHERE DES/GN /2' AMBIENT IS -/0°F OR LOWER, MIN HEIGHT IS 24' MIN OPEN OR CLOSED SPR/NG VIBRATION ISOLATORS, SEE SPECIFICATIONS !1' GAS UNIT HEATER DETAIL 1/" 4 FT MAX /8' MIN VENT (FLUE EXHAUST) TERMINAL -- DOUBLE-WALL VENT PIPE SEAL WITH SILICONE ,7/."-- SEALANT SUPPLIED WITH VENT /(/T Ngt COMBUSTION A/R /N // 2' /F ROOF /S • COMBUSTIBLE , TOP OF BOX DEC 24201B 17 oio REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 7 201 City of Tukwila BUILDING DIVISION CITY OF TUKWIL1=ti DEC 1 5 2017 PERMIT CENTER SHADED AREA REQUIRES CONTINUOUS SECTION OF DOUBLE-WALL VENT PIPE (NO JOINTS) • FLASH/NG (FIELD -SUPPLIED) ‘OF CONCENTRIC ADAPTER BOX COMBUSTION — A/R PIPE • INLET A/R CAP MUST BE AT LEAST 6" HIGHER THAN ANTICIPATED SNOW DEPTH DOUBLE-WALL VENT P/PE ATTACHED TO VENT R MORE THAT 6' FROM NOT TO SCALE CITY 0 AUG PERM c D KWILA 017 SAKE REINDERSMA ARCHITECT 5450 E. HIGH STREET, SUITE 200 ScoTTSDALE, ARIZONA 85054 P: 480.515.5123 F: 602.513.7193 WWW.SRA36O.COM ARCHITECT: STRUCTURAL: 0 -4 mgAso lV U Was.. 0E7 !lb 111 W Lt8 v w 0 0 ›- CX CX W O ~ Q Uj Q W d5 Q Gr OCA F- - >- w DATE: DATE: 8-3-2017 ISSUED FOR: PERMIT SUBMITTAL REVISION NO.: DATE: JOB NO.: 17-027 SHEET TITLE: MECHANICAL DETAILS Engineering Acumin ates, Incr F Nlte• 6 .`i`rris Fuh 80 ' Y' 1 1106 W. Maryland Ave. oeek AZ 85e13 la de@liglaseay.eem TLA # m22 MP SHEET TITLE: MECHANICAL DETAILS Engineering Acumin ates, Incr F Nlte• 6 .`i`rris Fuh 80 ' Y' 1 1106 W. Maryland Ave. oeek AZ 85e13 la de@liglaseay.eem TLA # m22 MP