Loading...
HomeMy WebLinkAboutPermit M17-0201 - STERLING SOUTHCENTER - NEW APARTMENTThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M17-0201 STERLING SOUTHCENTER 411 BAKER BLVD THE ABOVE MENTIONED Page # DIGITAL Code RECORDS PERMIT FILE INCLUDES Exemption (DR) EXEMPTION LOG THE FOLLOWING REDACTED INFORMATION Brief Explanatory Description StatutelRule Personal Information — The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 182 DR2 Financial Information — RCW 42.56.230(4 5) account numbers, which are exempt from disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. 42.56.230(5) Personal Information — Driver's License. RCW Redactions contain information used to prove RCW DR3 — identity, age, residential address, social security 42.56.230 (7a 42.56.230 (7a & c) number or other personal information required to apply for a driver's license or identicard. & c) Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW DR4 Attorney -Client Privilege — RCW 5.60.060(2)(a); RCW disclosure pursuant to RCW 5.60.060(2)(a), which protects attorney-client privileged 5.60.060(2)(a); RCW 42.56.070(1) communications, and RCW 42.56.070(1), which protects, under the PRA, information exempt or prohibited from disclosure under another statute. 42.56.070(1) STERLING SOUTHCENTER 407 BAKER BLVD BLDG MI 7-0201 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0223100080 Permit Number: M17-0201 407 BAKER BLVD UnitBLDG Project Name: STERLING SOUTHCENTER Issue Date: 5/25/2018 Permit Expires On: 11/21/2018 Owner: Name: Address: Contact Person: Name: BAKER BOULEVARD ASSOCIATES 2100 MAIN ST #150 , HUNTINGTON BEACH, WA, 92048 DARREN LOWE Address: 14900 INTERURBAN AVE S - SUITE 283 , TUKWILA, WA, 98168 Phone: (206) 674-4553 Contractor: Name: OCEAN PARK MECHANICAL INC Phone: Address: 14900 INTERURBAN AVE #283, TUKWILA, WA, 98168-4654 License No: OCEANPM024M1 Expiration Date: 7/11/2018 Lender: Name: Address: DESCRIPTION OF WORK: APARTMENTS - HEATING/COOLING/VENTILATION. COMMON AREAS - HEATING/COOLING/VENTILATION. GARAGE VENTILATION. EMERGENCY GENERATOR VENTILATION. CORRIDOR PRESSURIZATION. COOLING OF ELEVATOR MACHINE ROOMS. SMOKE CONTROL (STAIR PRESSURIZATION, ELEVATOR PRESSURIZATION, CORRIDOR SMOKE EXHAUST). Valuation of Work: $1,200,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $12,621.05 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: ?3f( I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:• Print Name: .c, : 1,1 t J. Aff71'4J04/ Date: 0// fp This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 4: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 23: TO SCHEDULE ALL FIRE INSPECTIONS CALL 206-575-4407. 12: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 22: The building smoke control system shall comply with the smoke control permit issued by the Tukwila Fire Marshal's Office to Allen Engineering. 13: H.V.A.C. units rated at greater than 2,000 cfm require auto-shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air-moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air-duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH-IN MECHANICAL 0704 SMOKE CONTROL TEST 0702 SMOKE DETECTOR TEST CITY OF TUKWIL!1 Community Development'Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 022310-0080 'Site Address: 415 Baker Boulevard, Tukwila, WA 98188 Suite Number: Floor: New Tenant: ❑ Yes ..No Tenant Name: PROPERTY OWNER Name: Baker Boulevard Associates, LLC Address: 7918 Green Lake Drive North City: Seattle State: WA Zip: 98103 CONTACT PERSON — person receiving all project communication Name: Darren Lowe Address: 14900 Interurban Avenue, Suite 283 City: Seattle State: WA Zip: 98168 Phone: (206) 674-4553 Fax: (206) 674-4564 Email: darren@oceanpm.com MECHANICAL CONTRACTOR INFORMATION Company Name: Ocean Park Mechanical Address: 14900 Interurban Avenue, Suite 283 City: Seattle State: WA Zip: 98168 Phone: (206) 674-4553 Fax: (206) 674-4564 Contr Reg No.: OCEANPM024M1 Exp Date: 07/11/2018 Tukwila Business License No.: BUS -0101045 Valuation of project (contractor's bid price): $ 1,200,000 Describe the scope of work in detail: Apartments - heating/cooling/ventilation. Common areas - heating/cooling/ventilation. Garage ventilation. Emergency generator ventilation. Corridor pressurization. Cooling of elevator machine rooms. Smoke Control (stair pressurization, elevator pressurization, corridor smoke exhaust). Use: Residential: New Commercial: New Fuel Type: Electric Gas Replacement Replacement Other: H:\Applications\Forms-Applications On Line \2016 Applications\Mcchanical Pcrmit Application Revised 1.4.16.docx Revised: January 2016 bh Page 1 of 2 . Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 58 Furnace >100k btu 395 Floor furnace 181 Suspended/wall/floor mounted heater 347 Appliance vent 333 Repair or addition to heat/refrig/cooling system 181 Air handling unit 65 dB(A) <10,000 cfm 2 Unit Type Qty Air handling unit 58 >10,000 cfm 395 Evaporator cooler 181 Ventilation fan connected to single duct 347 Ventilation system 33 Hood and duct 20 Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 1 Unit Type Qty Fire damper 58 Diffuser 395 Thermostat 181 Wood/gas stove 57 dB(A) Emergency generator 1 Other mechanical equipment 20 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally,,if sound can be:heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source 1 District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) i 1 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) i 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES. - Value of construction — in all cases, a value of construction amount' should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Steve Boak Mailing Address: 14900 Interurban Avenue, Suite 283 H:\Applications\Forms-Applications On Linc\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Date: Day Telephone: (206) 6434840 Seattle WA 98168 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R17445 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $72.10 M17-0201 Address: 407 BAKER BLVD UnitBLDG Apn: 0223100080 $72.10 Credit Card Fee $2.10 Credit Card Fee R000.369.908.00.00 0.00 $2.10 MECHANICAL $70.00 ADDITIONAL PLAN REVIEW R000.345.830.00.00 1.00 $70.00 TOTAL FEES PAID BY RECEIPT: R17445 $72.10 Date Paid: Friday, April 19, 2019 Paid By: TERRIS PATTERSON Pay Method: CREDIT CARD 01060D Printed: Friday, April 19, 2019 11:51 AM 1 of 1 (rI L.! IJ LJ SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY PAID $10,193.93 M17-0201 Address: 407 BAKER BLVD UnitBLDG Apn: 0223100080 $10,193.93 Credit Card Fee $296.91 Credit Card Fee R000.369.908.00.00 0.00 $296.91 MECHANICAL $9,425.73 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $9,392.58 TECHNOLOGY FEE $471.29 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14582 R000.322.900.04.00 0.00 $471.29 $10,193.93 Date Paid: Friday, May 25, 2018 Paid By: TERRIS PATTERSON Pay Method: CREDIT CARD 09789D Printed: Friday, May 25, 2018 2:34 PM 1 of 1 CIMPWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY rr PAID PermitTRAK $2,427.12 M17-0201 Address: 415 BAKER BLVD BLDG Apn: 0223100080 $2,427.12 Credit Card Fee $70.69 Credit Card Fee R000.369.908.00.00 0.00 $70.69 MECHANICAL $2,356.43 PLAN CHECK FEE R000.322.102.00.00 0.00 $2,356.43 TOTAL FEES PAID BY RECEIPT: R13081 $2,427.12 Date Paid: Thursday, December 21, 2017 Paid By: ERIC BOAK Pay Method: CREDIT CARD 711221 Printed: Thursday, December 21, 2017 3:12 PM 1 of 1 C1SYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 04/19/2019 11:50:59 AM CREDIT CARD SALE VISA CARD NUMBER: **********8125 K TRAN AMOUNT: $72.10 APPROVAL CD: 01060D RECORD #: 000 CLERK ID: jazzel X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 N!7 czo) P�ral1ec_t: �l� .J R'� Yl� Type af InC , ' 6 V i /1�1q'� Address: J �� 41</ 3,� e- pJ / Date Called: Special Instructions: Date Wanted: 0-A1F_9 a.m. p.m. Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspector'. REINSPECTION FEE REQUIRED. Prior to next ins'ection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1'117-olol Proj ct: fsc),41,e W3 r T of I pectiQn: t" CCI -1. Cjit7 ddress: W/ Bi* 8Gv Date Galled: 1, 3 u116;•,,ichva._ ,.S,n Special Instructions: Date WanntLted: �n aJ - 2✓ l9 a.m. p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: flircaL F A701 , Pnekt 1, 3 u116;•,,ichva._ ,.S,n V Smoke Ca► L .5etol QL4- I- t SIS• 0f s5 Ai,rc /" -C► -w) rim_ Fes. Inspector: Date: f2. "/20/ —"� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit M17 -oto/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Sect: 1 1 i (� T of l cat_ LVii L. Address: 167 9/94<zA.r3Ivre Date Called: Special Instructions: Date Wanted: /Z_2_Zd1T a.m. p.m. Requester: Phone 83 z. 601444. 1170 Approved per applicable codes. Corrections required prior to approval. COMMENTS: XerifriatIc‘r_a_r ¢i NfL a4r�i five/f,., c a9ialtet I doer i JOY' Cruind-f\anattie,y rZpol-c. Inspector:0 Q REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Ml7-Ozol P l'W` ! S�yl Type of Inspectioeiten'gr n: ce.1- 6 Addo117 LVid ate Called: Special Instructions: Date Wanted: a - /3 • 2°15 a.m. p.m. Requester: Phone No: EDApproved per applicable codes. COMMENTS: orrections required prior to approval. 6- gp_- Akio)" sal Inspector -a cQ G --t Date: Teo/5 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 MI7- 0201 te,r I1 tdileery Tye 1=1; V CAL, w,. Adpress: t/07 B OO- bLvd Date Called: Special instructions: Date Wanted: 6J J 6 ,0015 a.m. p.m. Requester: Phone No: p0Approved per applicable codes. Corrections required prior to approval. COMMENTS: rAiet& KroProp InspectorRQCEL.. Date: ll -6 (6 , Z-61* n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit MI7-024 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 S tPr.�` 1� of I �spe tion:`�� Address: r0 407 keir- 13/vol Date Called: Special Instructions: Date Wanted: ,(,14 rytWil a.m. m. Requester: Phone No: EJApproved per applicable codes. Corrections required prior to approval. COMMENTS: yal - 4,37 "frP t -rd /.d hark i/141&y.D (ex [la Cts, F t'cjA reK, u2 Inspector: C REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M I7- oZ6/ SProtAA t � �� Y1q Type of I spectio� / `_ , t A/ riL Address: V 07 Bek . Date Called: Special Instruct ons: fL_c;o 4 57". Y A ` .k OA ty Date Wanted: a.m. /d'9- ZOL/ p.m. Requester: C Phone No: EiApproved per applicable codes. Corrections required prior to approval. COMMENTS: �(�'� x����s p L Y ,(% Lo ctAct.1 c c.L / rJ 1 iryy-f xS Rcor- (&'1 5oI_5,3' Inspector: E -SOC n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Mil-OZol Pr�aj{ect: earsee er I i '/Saul+ TRof Inspection(: Address: (� 6107 B4ke - BL -vi , Date Called: Special Instructions: Level -0 -"{ _ Phone Date Wanted:a.m. �/� `v - 7' p.m. Requester: No: Approved per applicable codes. oCorrections required prior to approval. COMMENTS: aleci,Awicez_ F;A/4 /047-77Z) x-6* r-Lob-Y- inspector:s� Date: /0/%/00/ ,-, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 1117-0261 Project: Si'er1.iAl Sati4) - Type of Inspection: l,ech�.w►Ic� Fit 't. Address: a N -74-a-- avl iiii6 c/V 75l'h ie -e, - ate Called: Special I 77 ru ons: �/..C_�.C�J,.y.. �� X143 Date Wanted:/0 3.20/1 a.m. p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS:� ,,h4L ��':' i 1 tif�CA'VtACaL F ' _i (uv+s Qtsu..y iCJI,n►ts -1D ! — 341e-,7--zyr4 " W Q LY"/ N -74-a-- avl iiii6 c/V 75l'h ie -e, - axe tt/ iikeved(' Date/D-3- REINSPECTION ateD-3- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit /11/7- O20/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: sreRI- 6— Type of Inspection: ,'JT C/400 -LU -n Addree/ssss: p (/� Date Called: Special Instructions: Date Wanted: q —2b 19 a.m. P.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS A M'7L/ LJ, /9-/R (R i) .7SL)C7 s 4 6 . /y -z -N;-- 4/0/c77-74 u)fh.i- T yJR� 1409/ Inspector: Date: r-,20 -)7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje t: SatoeII.�ll..�k,- T of Ins ctioAstais ;as � A e7 m, B ♦ 4 �v Date Ca d: Special Instructions: • ' Dale Wanted: Q 9-4 - �l $ a,m. p.m. Requester: Phone No: p§ Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: *Rok.1/484-1,0 frkezew41.141 /— 5� ► &ittasc_ "r CC\dc..% �.�Sse.14:0,( P69-Af. Spector: Date: l / 5 Inspector:- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectiion. INSPECTION RECORD Retain a copy with permit M17-0201 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P o{{ect: • Ste -r I. I /50,,„,-1-hte*. of Ins e , Meefun;,eicie 0 Address: '#07 &ark al.Vb Date led: Special Instructions: Date Wanted: a.m.9n2-�� p e' Requester: ....._, 9.'/z— 1?. Phone No: 0 Approved per applicable codes. Ej Corrections required prior to approval. COM NTS: 0/ 1 JA)��Y�bnICG�/j- bietei(CZ,i44 rtzs4) M-Zr-t-71 &main/ StocADirvS �Ke 6`1A 4)66,71 ,& :&iJ& s.°°r) tnsuc"le to_A-DK- 7D ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 300 o�ut`.hcen ,r lvd., uite 100 It sch d� rei s�ct�'t n� LC) r/' �/, ( ()SSC INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1I17.,2z,l P,rr,o,,jggct: an, sootily ieeTy : of In ` ectio �) o. • ^e . if Date C Ired: Sjjpeiee ial Instructions: Wanted:,‘ Date Wanted: -- ` a.m. p.m. Requester: �&,—SLAsi- 3 &e(d Phone No: cores w tom, Air pproved per applicable codes. Corrections required prior to approval. COMMENTS: L ,47)4 f %.* -- » ( mace_ Ad- " �&,—SLAsi- 3 &e(d I A/ ' 17V P —eNc ro cores w tom, 5fZ ....7i........, OA_ IV CIDLoS'" _ ,. ,e -m REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 SouthceM r Blvd.. Suite 100. Call to schedule reinspection. LzxL,S * Z°—Orc. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �TTie%!N� U,� Type of Inspection: R61)C/1- /N ae='el>IW cAL Address: '67 B4/<(#? g1_vD, Date Called: Special Instructions: gvvjck L✓/-» I/ 3 /5-7- 5"7z),e, e ,p/fr7 y Date Wanted: / q g 7' 6 /9 a.m. p.m. Requester: 5/3YAio-- --1 l-hALsnaV 0 K— 7D Ccvi,CR, Phone No: .832-6 -0 «4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: FA is L IR, ritreAM ICA L it-°PRb i) 515 ewe 0 K— 7D Ccvi,CR, PVV4S ?V3, '99, ,3'. - g,3'. - Inspector: is Date: 17 C REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION M17-o2oJ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: ,,S -i rLt �Seu4A ce�n+er Type of Inspection: - , S. 1`�eck icc � Address: 407 alker 3.vd Date Called: Special Instru�ctijons: M� "ftt 5E F- RI Date Wanted: a.m g-7-2o.LQ p.m. Re nester: T V;h4w►s,D N Paoli=Biz-(o126 Approved per applicable codes. Corrections required prior to approval. COMMENTS: tvle CANe r:1C.G.I. i<Olit littike-qf Ar/ 416(4 (Ds 3v4 rLbe", cam - M - AIl' ban,- vioK Inspector: 73(41 akyt._ Date: 8.-1-40/? - 40/p n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. \ . Ey Op aINSPECTION RECORD /INSPECTION NO. Retain a copy with permit Mil ow,' # CITY OF TUKWILA BUILDING DIVISION PEIT NO. 6:300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 'Project: - refL Type of Inspection: Q•'c' . MrentAcAt€014., Address: � k`qDate Date Called: ,l) Specinitruc ions: e„,, a << Wanted: nn ..• V _- t---c-,,,t, L_.£l u-1 C ,"Ck 2 i cel P�r g o a m. Requester: G I +( A 7 "ffY' ra k f� Phone No: 7 t,(u proved per applicable codes. Corrections required prior to approval. 'COMMENTS: J ti /!/�e4,,vi ie I-,9'Y LeveL 2- F(, y Garp, ,l) e„,, a << _- t---c-,,,t, L_.£l u-1 C ,"Ck 2 i cel P�r g o OP I- d ` 7,1.?12- A 7 "ffY' ra k f� 4/0 (�1k —® Inspector: Date:q,6 00)3 _ C REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit t1/467-6261 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 jec : t ProSTP-4/ Type of Inspection: ,�, nn .T. iNtece44...; tc...e,t— Address: go -7 t`ii�+' &J Dale Called: Special Instru ions: Date Wanted: 6 - Ze p.m. f Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: R _r Mcce..L�-/9j 'Yc- 01! Efg.3 m Leuei c 3 -Co ++ S',Asi)- � 4;4‹,5,6 D, ca AcEr-k2 (.00-‘ 3 --LQ F.RR3 t\ic hu As 4- 6 x pilt)LAR Sk_e4-CA--( Ma. u1/4- 511kt from F/-0015 3-= -7 —ot inspecto Ep I 3 _7 Date:04 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Cit JAW(S# Nebr.) L. —ori INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M17-0201 Projec Oa c IC T ��of+Ins on: ‘44/.. Ad/ressJ� !0/� ��� ate Called: q 82-Zv%/ Special Ifistructions: Date Wanted: — a.m. p.m. Requester: z Phone No: 24C6 - -4r2‘, !j Approved per applicable codes. Corrections required prior to approval. COMMENTS: YYI eee �. sP4,--01 REA-tourbeAei-w ,� dor FitP1 6icG 3 i Fcir '',:::) n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permits owl INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:Type ,'J eez.A. A. d.IrL of Inspection: Z..= M r Address: Date Called: Special Ins ructions: Date Wanted: a.m. 4• ,•• 11 p.m. Requester: 13 T Phone No: Zoo iffeL. &li0 pproved per applicable codes. Corrections requir�rior to approval. 'COMMENTS: CR % }TY', T/tIZJI\l Cec,1---1?Ziks4/ GIC2 .** e c,- z &t, Attz-t n _ Mik. .Klie_ b)PkAp far V@14J6ivgiii--- -cD,5.6-- 6;-1-600 j-Q1/5(P ri.ed(-2 2(45 'l1� gcvs, - O 7 ' v 11 LLese \e 4z scioce Lrs� V-ir- 1 v 14.-e wa-p, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: % 'r T of Ins ectio:' �J� „ , cal Address: BLve/ Date Ca{ d: Special Instructions: _. Date Wanted: : "7-30— DvPrr— Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. lt5a COMMENTS: LbJ,�J /k12,) \ic.cei ucc-V-) CfilP1-t Pv_,edy,\-\c_caL aus)\— fyonel Tvolt c:', X11 L3,1( V2S9d 1;bt-Zi,&IL 111. Inspecto`a C Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1 r7 o o Project:..--'' � ��// Type of 1ns ectiioon: 4th i. Address: �,�- i 2 Date Called: Special Instructions: Date Wanted: a.m. -ZZ p.m. Requester: Q� A(`4,'- Phone No: ZAP ASz Gi r.4, Approved per applicable codes. LJ Corrections required prior to approval. M M ENTS: c ' s r'wf u P4r-11.4)' ")( Lete) I r ifell416M-- krrrt-c - at" rEs 30 I -3614/ Date• REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit turn ova) INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: . C.1�.1.44/7 Type of Inspection: ��( 1����Iy����. Y'/ (At Address: A, Date Called: Special lnstfuctions: Date Wanted: elMS a.m. p.m. Requester: 13 Phone No: eZ406 f33Z 4121v ❑Approved per applicable codes. Corrections required prior to approval. COMMENTS: ()fleck Leet 2 (w" %is a_o/ ofeaoa (A) LeveL 2 (Com0A) lAitteocv v X*3 OP fim-ci>44if rodYfri_re441( �IV �ufs,�9w Ar/Dn�l S �. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 111/7- a20) Project* Ty f In ectiop A ess_g 0646, gerSpecial Date Called: Instructions: Date Wanted: 1/47.—` S— a.m. p.m. Requester: Phone No: ' I Approved per applicable codes. Corrections required prior to approval. /COMMENTS: 0-4 CP4� akid,eueL 3rs\ 4 VT`s GtV4S 3o4-_715— —01( t p)i1 'al- C13 Date: gig— REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M17 -02o1 Project:( S Tye of Inspection: ss: V AddreZiitions: Gr� ", Date C ed: peciL) DateWanted: "i -IS --Z 9 a.m._ p.m. Re ter: Phone Approved per applicable codes. El Corrections required prior to approval. COMMENTS: '/U Y Ylee t /.-etie_l_ U4A+ e#14 itt 3/7-33 Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /1117-020/ Proj t: / irk/ I , f ee, Typ Ins ction: Address: U Date Called: Special instructions: Date Wanted: 7-3 ` 20/ a.m. p.m. Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: Xei? %tiW fi�M fir- ✓��-c�.e 36-4049&-ig ari/eciek iv? 31d kop Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee st be pajd atc6300 Sothcentt r Blvd. cite 100. Call to schedule rei spection. 7t2v/� INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PERMIT NO. Project: Type of Inspection: Address: 101 131/4WWL Date Called: Special Instructions: Date Wanted: 6 -z-s' 1 3 p.m. Requester: 147 Phone No: ?.Ata e32- 444-&, pproved per applicable codes. El Corrections required prior to approval. CMENTS: CP0 vic A ) y t iC--- y 7rt FLoov (Udi-i-i V-rwc, dr u„W- Veer1+ie5 alp tvnlli «9///(': �'P.-lcvS' % /J 1Dateb ` y� n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO;. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 lrll1- 024 r4.14,,tiT�Insp tion:C_�C_ �eC /� t 1�- ss: � 2-10 7 B&'/v/ Date Called: Special Instructions: Date anted:_/ ^ Z �j a.m. p.m. Re uester: Phone No: Approved pe MM a • e c+ : - Ll Corrections required prior to approval. �yL c� Cv r L1 S )L izs)c�C ,Sn� P G�u�s.l�6/C �Le%eL yv--7-floct and ati x u y/7- oic 70 Inspector: Dater Zlvzo/ I ! REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit t ozoJ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: Type of Inspection: Address:Date 4i YEA) s,..,!(> Called: Special Instructions: f &L ,.5' 1��'S � `" � Date Wanted: 4.- /2- /9 a.m. p.m. Requester: r)i Phone No: 2 e3Z 4/2 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 4,‘ ent) C Vidtite (/155 ti#1/° �a (901-6/7 Inspector:/ f� Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: `�l� / Type of 1 ection: p�� Ej- Address: 401 Y i, $1"/n Date Called: Special Instructions: Date Wanted: a.m. Requester: Q gefolvt Phone No: Zo(e132 61UP ZN Approved per applicable codes. Corrections required prior to approval. MMENTS • R1-r, On -0 lAc4,--,(c-AL (tic v114( ULfri ~s '117-4`3 Inspector: Date:/__C _ ze2/7 I l REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1(n oaf Project: Sze2tf.✓6. Type of Inspection: 1 l Address: 47 144k -en, v3r-v0 Date ailed: Special Instructions: /� 2,o..,(® Date Wanted: i'•2i- I4, a. p.m. Requester: ,e' y' 16 tvlSperira0 Phone No:Mv' zao 632 /zita. r Approved per applicable codes. ■ Corrections required prior to approval. COMMENTS: x . o ( --44- ,4 -Yr Un'ci--- \je,r--ific. ail- 6 F-L2or uun.;+5 (.o d t - i -- oK___ fir)'-- rpv' +__ kc1`- R o veL tvlSperira0 3 -cl: F(t S — Inspector: / I Q Date:,c_ 2.4- Z017 I ! REINSPECTION FEE REQUIRED. Prior to next inspection, fee muss be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Vli17 12al Project: '' k4ILZ-wJZ0 Type of Inspection: 2- . . liVc 6-kiCA-L_. Address: ltp', la At rt, P� r✓9 Date Called: / ^^��,,,� ) %c-1. e�N Special Instructions: Date Wanted: a.m .17--, 96-/9 p.m. Requester: Phone No:""fT 7 -2- 6l?ip 2 Approved per applicable codes. Corrections required prior to approval. COMMENTS: R.I, H/4„,„) / �e �E,- I,SGufSP 1l�S 4,7� r ani Pvoc)ed t&ifes 4;5. Alai - tAJe6.441ced .7j4/1 ROLtYJCr�r�se moo« -T-D Inspector Q cQi 2 Date/ /z Z /C REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 410 0201 Project:Type /� iv`/ of I pection: ' d , /'"L GY+Z Address: /j `O7 �� //1 ,�l.�f/J Date Called: Special Instructions: Llio /�'2 1 Date Wanted: e % i % a pm. Requester: Phone N 2 Z A 24, Approved per applicable codes. Corrections required prior to approval. COMMENTS: R(Tr Vitlatx 11-cr SAAIC-4c5 (fifrt; ve_eoKes(6rce Fccot---) ut1,1.4--s I — - Inspecto7'.�, Date j7` I ! REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 owl Project:kp .�A A' , Type of Inection: � i ��� Address: Date Called: Date Special Instructions: Date Wanted: A -N^ (dm -ICI p.m. Requester: Phone No: 4zs 7e/ sL37 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Aeltiornvc- piekkiw yeff anc F/6'6/7 Date: 5 / 0e7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspecrtion. Inspector3 INSPECTION RECORD Retain a copy with permit frit it 7' 0201 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj,ct:. ' S\erL 4 `Sn • (1.094p Tof In pection: �mt.) �z z Address: ate d:g Special Instructions: bate Wanted: a.m. p.m. Requester: j Phone No: 1– 9a3. ---2g1-54-37 proved per applicable codes. Corrections requir prior to ap • •val. COMMENTS: "Kgtic tAint-V Ve4+1 .getcp PT/wird- 1 - 7/7- 7 ,_5Dfierfc , Inspector: Date ! z5 Cj n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 114h 620I PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: 'Special Instructions: L1 �� Date Wanted: / / ! ca•m.- p.m. Requester: Phone No: t 425 2�1 5151 Approved per applicable codes. Corrections required prior to approval. OMMENTS: /1/L0.0:Ilan.," Aff-4 re_ froe9 btutL 7CCA �G 7bTo 1'C-,, 1 X- Se -in -Fr. CRZ 4/< SEP Duci-Q.Dov-iL(cpver 3-L Inspector: A� Dateq,/67 „3,5 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 rl -ozo( Proc 6 I - SO -u41 / vim' CPil�TL.r' 7y� pection: t l Ecp .` �.t'�w,i l, Address: (� 1107 &Veer (Lv Date Calle Special Instructions: Date Wanted:a.m. ( Requuuester: Phone No: Approved per applicable codes. COMMENTS - rections required prior to approval. Inspector: Date: -17L-Z47/7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 017-a20/ / PPg ct: I --/C j� /gyp � >� wY lam`-+ 4 Tygeof Inspec ' n: Y� JJ V'I Address: i I/v7&V &id' Date Called: Special Instructions: Date Wanted: Li -3 -1017 a.m. Vii l S a 'l c, \ rA/i' S t Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COM,, . 2-14 S-4ck -7 s 7T r''Loor s AV(--vtd-e17;‘—t(5 isf Ar g2 ek ;c4j ! ✓l%,,,i ik.,, is/ -Ales V Mots- Sp /i7$ Vii l S a 'l c, \ rA/i' S t 6��4 — Olt Codt nldP_ , nspector: l n Date: y_3 _2,017 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ruri Geo! Project: Type of Ins ection: Address:'' 401 ,,//` i'1-4 Date Called: 2)'1 5 Special Instructions: DyleA 9 70 -Z4,0 - 6 Date Wanted: 3. i1- a.r>S' p.m. Requester: J 0 f - DRS/(2,4)- fir Phone No746 g ‘f3 f24 ; S cc, inp/i5 Approved per applicable codes. Corrections require 1. COMMENTS: ;2_,...:4siiG44_ / Uvc- 2)'1 5 If— 7, / 0 f - DRS/(2,4)- fir f24 ; S cc, inp/i5 Ae-K5, 4 (jam -H'ir) knsikair g ; t F sTP- -cti-,. Inspector: Dater _07,ze y REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 206) 431-3670 Permit Inspection Request Line (206) 438-9 Project: T .e�o Inspection: 1 Address: 41. E`:.��g ate Called: Special Instructions: Date Wanted: 10,22:-.t1 . p.m. Requester: Phone No: ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: VL1- _ <-1 g.32 -672C, Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid',at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. AIRIEST Co., Inc. Test & PROJECT: LOCATION: PROJECT #: Balance Report Marvelle - Sterling Southcenter Tukwila, WA 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: FIRM: AIRTEST Co., Inc. PO Box 86 Issaquah, WA 98027 PROJECT: Marvelle - Sterling Southcenter 415 Baker Blvd Tukwila, WA 98188 NOTES: PHONE: 425-313-0172 FAX: 425-313-5735 DATE: 12/4/2019 PROJECT #: 19-1058-1 CONTACT: Kehoe, Mike AIRTEST Co., Inc. TAB Report AIRTEST Co., Inc. Table Of Contents PROJECT: Marvelle - Sterling Southcenter DATE: 12/4/2019 LOCATION: Tukwila, WA CONTACT: Mike Kehoe PROJECT #: 19-1058-1 AUTHOR: Table Of Contents 1 Field Note Report 1 2 Make -Up Air Unit 2 2.1 MUA-R-01 2 2.2 MUA-R-02 3 3 Fan Coil 4 3.1 FCU -01 4 3.2 FCU -02 3.3 FCU -03 6 3.4 FCU -04 7 3.5 FCU -05 8 3.6 FCU -06 9 3.7 FCU -07 10 3.8 FCU -08 11 3.9 FCU -09 12 4 Fan Unit 13 4.1 EF -01-02 13 4.2 EF -R-01 13 4.3 EF -R-02 14 4.4 EF -R-03 66% 14 4.5 EF -R-04 77% 15 4.6 SF -01-01 15 5 AIRTEST Co., Inc. TAB Report AIRTEST Co.. Inc. Field NoteReport PROJECT: Marvelle - Sterling Southcenter LOCATION: Tukwila, WA PROJECT #: 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: Test Fan Unit Fan Coil System Unit Name EF -01-02 FCU -03 Date 2 -Dec -19 26 -Nov -19 Contact Mike Kehoe Mike Kehoe Notes/ Comment Logs Fan label is not visible Unit is on high speed AIRTEST Ca, Inc. Page 1 of 15 TAB Report AIRTEST Co., Inc. Make -Up Air Unit PROJECT: Marvelle - Sterling Southcenter LOCATION: Tukwila, WA PROJECT #: 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: MUA-R-01 AREA: Corridors North Unit Data Unit Manufacturer Sterling Unit Model Number PV25A2B01J63P2AB5 MUA-R-01 Supply Outlet Summary Tested By: Mike Kehoe Date: 12/3/2019 Motor Data MUA-R-01/Supply Fan Motor HP Motor Rated Volts Motor Phase Motor Hertz 3 HP 208 Volts 3 60 Hz Air Test Data Total CFM Design 4000 CFM i System/Unit Area Served Outlet Type Size LxW / D Design CFM Prelim Reading Final Reading % Final Outlet -01 Level 7 SG 18/12 700 490 - Outlet -02 Level 6 SG 18/12 700 675 -- Outlet-03 Level 5 SG 18/12 700 580 Outlet -04 Level 4 SG 18/12 700 700 Outlet -05 Level 3 SG 18/12 700 790 Outlet -06 Level 2 SG 12/6 200 185 Outlet -07 Level 2 SG 10/6 100 100 Totals: - - 3800 3520 0 0 AIRTEST Co., Inc. Page 2 of 15 TAB Report AIRTEST Co., Inc. Make -Up Air Unit PROJECT: Marvelle - Sterling Southcenter LOCATION: Tukwila, WA PROJECT #: 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: MUA-R-02 Unit Manufacturer Unit Model Number Unit Serial Number Sterling PV25A2B01J63P2AB5 A1901647774002001 MUA-R-02 Supply Outlet Summary Tested By: Mike Kehoe Date: 12/4/2019 MUA-R-02/Supply Fan Motor Manufacturer Motor HP Motor RPM Motor Frame Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor Baldor 3 HP 1765 RPM 182T 208 - 230 Volts 3 60 Hz 8.4 Amps 1.15 IZMO MUA-R-02/Supply Fart Drive Type Belt Size Number of Belts Motor Sheave Motor Sheave Bore Motor Sheave Position Fan Sheave Fan Sheave Bore Sheave Center Line Belt B44 1 1VP50 1 1/8 in. Mid BK70 1 in. 14 1/2 in. Air Test Data Total CFM Design 3850 CFM Filter Data MUA-R-02/Filter Filter Manufacturer Filter Type MERV Rating Filter Quantity Filter Size AAF Pleated 8 4 20x20x2 Inches AIRTEST Co., Inc. TAB Report Page 3 of 15 =Served Outlet TOM-WO M®i7 0' Design Prelim UJ Readin. TOM— CFM Readin. Outlet -01 Level 7 SG 18/12 700 585 Outlet -02 Level 6 SG 18/12 700 635 Outlet -03 Level 5 SG 18/12 700 675 Outlet -04 Level 4 SG 18/12 700 750 Outlet -05 Level 3 SG 18/12 700 780 Outlet -06 Level 3 SG 10.6 150 0 Outlet -07 Level 2 SG 10/6 100 80 Outlet -08 Level 1 SG 10/6 100 135 Totals: o o 3850 3640 W CI AIRTEST Co., Inc. TAB Report Page 3 of 15 AIRIEST Co., Inc. Fan Coil PROJECT: LOCATION: PROJECT #: Marvelle - Sterling Southcenter Tukwila, WA 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: FCU -01 AREA: Main Floor Offices Unit Data Unit Manufacturer Unit Model Number Unit Serial Number Carrier FB4CNP024 2817A74310 Test Data Fan Speed External SP Design High 0.5 in. wc. Electrical Test Data Motor Volts T1-T2 Amps T1 211 Volts 2.1 Amps FCU -01 Supply Outlet Summary Tested By: Mike Kehoe Date: 11/26/2019 Motor Data Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps 1/3 208-230 1 60 Hz 2.8 Amps Sheave Data Drive Type Direct Drive Air Test Data Total Fan CFM Design Total Fan CFM Act. 800 CFM 775 CFM Filter Data Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 AAF Pleated 1 14x20x1 System/Unit Outlet -01 Outlet -02 Outlet -03 Outlet -04 Area Served Manager Assist Manager Conference Sales Totals: Outlet Size LxW / Design 1 Prelim Type D CFM CD CD CD CD 8 RD 8 RD 8 RD 8 RD 200 200 200 200 800 Reading 160 155 160 225 700 Final Reading 200 185 190 200 775 Final 100 93 95 100 97 AIRTEST Co., Inc. TAB Report Page 4 of 15 AIRIEST Co., Inc. Fan Coil PROJECT: Marvelle - Sterling Southcenter LOCATION: Tukwila, WA PROJECT #: 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: FCU -02 AREA: Great Room 104 Unit Data Unit Manufacturer Unit Model Number Carrier FB4CNP048 Test Data Fan Speed Extemal SP Design Med 0.5 in. wc. Electrical Test Data Motor Volts T1-T2 Amps T1 210 Volts 4.8 Amps FCU -02 Supply Outlet Summary Tested By: Mike Kehoe Date: 11/27/2019 Motor Data Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps 3/4 208-230 1 60 Hz 6.0 Amps Sheave Data Drive Type Direct Drive Air Test Data Total Fan CFM Design Total Fan CFM Act. 1600 CFM 1680 CFM Filter Data Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 AAF Pleated 1 20x24x1 System/Unit Area Served Outlet Type Size LxW / D Design CFM Prelim Reading Final , Reading % Final Outlet -01 Great Room 104 SG 18/6 267 290 290 109 Outlet -02 Great Room 104 SG 18/6 267 270 270 101 Outlet -03 Great Room 104 SG 18/6 267 260 260 97 Outlet -04 Great Room 104 SG 18/6 267 300 300 112 Outlet -05 Great Room 104 SG 18/6 267 295 295 110 Outlet -06 �..__._ Great Room 104 SG 18/6 267 265 265 99 Totals: 1602 1 680 1680 105 AIRTEST Co., Inc. TAB Report Page 5 of 15 AIRT'EST Co., Inc. Fan Coil PROJECT: LOCATION: PROJECT #: Marvelle - Sterling Southcenter Tukwila, WA 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: FCU -03 AREA: Bistro 103 / Lobby 102 Unit Data Unit Manufacturer Unit Model Number Unit Serial Number Carrier FX4DNB061L 4619F50903 Test Data Fan Speed Extemal SP Design High 0.5 in. wc. Electrical Test Data Motor Volts T1-T2 Amps T1 210 Volts 5 Amps Log: Tested By: Mike Kehoe Date: 11/26/2019 Motor Data Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps 3/4 208-230 1 60 Hz 6.0 Amps Sheave Data Drive Type Direct Drive Air Test Data Total Fan CFM Design Total Fan CFM Act. 2000 CFM 1565 CFM Filter Data Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 MF Pleated 1 20x25x1 FCU -03 11/26/2019 Mike Kehoe Unit is on high speed FCU -03 Supply Outlet Summary System/Unit Outlet -01 Area Served Lobby 102 Outlet Type CD Size LAW / D 8 RD '' Design CFM 250 , Prelim Reading 160 iFinal 1 Reading 175 % Final 70 Outlet -02 Lobby 102 SG 12/6 250 240 250 100 Outlet -03 Lobby 102 SG 12/6 250 170 175 70 Outlet -04 Lobby 102 SG 12/6 250 195 220 88 Outlet -05 Lobby 102 SG 12/6 250 180 190 76 Outlet -06 Lobby 102 SG 12/6 250 190 200 80 Outlet -07 Bistro 103 CD 8 RD 250 165 180 72 Outlet -08 Bistro 103 CD 8 RD 250 165 175 70 Totals: r - L ' - [_ 2000 ` _.r 1465- _, 1565 78 AIRTEST Co., Inc. TAB Report Page 6 of 15 AIRTEST Co.. Inc. Fan Coil PROJECT: LOCATION: PROJECT #: Marvelle - Sterling Southcenter Tukwila, WA 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: FCU -04 AREA: Reading Room/Lounge 214 Unit Data Unit Manufacturer Unit Model Number Unit Serial Number Carrier FB4CNP025 0319F30872 Test Data Fan Speed External SP Design Med 0.5 in. wc. Electrical Test Data Motor Volts T1-T2 Amps T1 211 Volts 1.7 Amps FCU -04 Supply Outlet Summary Tested By: Mike Kehoe Date: 11/27/2019 Motor Data Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps 1/3 208-230 1 60 Hz 2.8 Amps Sheave Data Drive Type Direct Drive Air Test Data Total Fan CFM Design Total Fan CFM Act. 600 CFM 635 CFM Filter Data Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 AAF Pleated 1 18x20x1 ' System/Unit Area Served Outlet -01 Outlet -02 Outlet -03 Reading Room/Lounge 214 Reading Room/Lounge 214 Reading Room/Lounge 214 Totals: Outlet Size LxW / Design Prelim r Final % Final Type D CFM Reading Reading SG SG SG 12/6 12/6 12/6 200 200 200 600 195 205 185 585 220 220 195 635 110 110 98 106 AIRTEST Co., Inc. TAB Report Page 7 of 15 AIRIEST Co., Inc. Fan Coil PROJECT: Marvelle - Sterling Southcenter LOCATION: Tukwila, WA PROJECT #: 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: FCU -05 AREA: Game Room 211 Unit Data Unit Manufacturer Unit Model Number Unit Serial Number Carrier FB4CNP024 0219F25153 Test Data Fan Speed External SP Design High 0.5 in. wc. Electrical Test Data Motor Volts T1-T2 Amps T1 211 Volts 2.4 Amps FCU -05 Supply Outlet Summary Tested By: Mike Kehoe Date: 11/27/2019 Motor Data Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps 1/3 208-230 1 60 Hz 2.8 Amps Sheave Data Drive Type Direct Drive Air Test Data Total Fan CFM Design Total Fan CFM Act. 800 CFM 775 CFM Filter Data Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 MF Pleated 1 14x20x1 System/Unit Outlet -01 Outlet -02 Area Served Game Room 211 Game Room 211 Totals: Outlet 'Size LxW / Design . Prelim Type D CFM , Reading SG SG 14/8 14/8 400 400 800 335 335 670 Final Reading 385 390 775 % Final 96 98 97 AIRTEST Co., Inc. Page 8 of 15 TAB Report AIRTEST Co.. Inc. Fan Coil PROJECT: LOCATION: PROJECT #: Marvelle - Sterling Southcenter Tukwila, WA 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: FCU -06 AREA: Theatre • Unit Data Unit Manufacturer Unit Model Number Unit Serial Number Carrier FB4CNP025 0319F30875 Test Data Fan Speed Extemal SP Design Low 0.5 in. wc. Electrical Test Data Motor Volts T1-T2 Amps T1 211 Volts 1.6 Amps FCU -06 Supply Outlet Summary Tested By: Mike Kehoe Date: 11/27/2019 Motor Data Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps 1/3 208-230 1 60 Hz 2.8 Amps Sheave Data Drive Type Direct Drive Air Test Data Total Fan CFM Design Total Fan CFM Act. 600 CFM 625 CFM Filter Data Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 AAF Pleated 1 18x20x1 System/Unit Outlet -01 Outlet -02 Outlet -03 Area Served Theatre Theatre Theatre Totals: Outlet Size LxW 1 Design Prelim Final % Final Type D CFM Reading Reading SG SG SG 12/6 12/6 12/6 200 200 200 600 230 275 210 715 210 195 220 625 105 98 110 104 AIRTEST Co., Inc. TAB Report Page 9 of 15 AIRIEST Co., Inc. Fan Coil PROJECT: LOCATION: PROJECT #: Marvelle - Sterling Southcenter Tukwila, WA 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: FCU -07 AREA: Fitness 345 Unit Data Unit Manufacturer Unit Model Number Unit Serial Number Carrier FB4CNP036 0419F34975 Test Data Fan Speed Extemal SP Design Med 0.5 in. wc. Electrical Test Data Motor Volts T1-T2 Amps T1 211 Volts 2.8 Amps FCU -07 Supply Outlet Summary Tested By: Mike Kehoe Date: 12/2/2019 Motor Data Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps 1/2 208-230 1 60 Hz 4.1 Amps Sheave Data Drive Type Direct Drive Air Test Data Total Fan CFM Design Total Fan CFM Act. 1000 CFM 1065 CFM Filter Data Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 AAF Pleated 1 18x20x1 System/Unit Outlet -01 Outlet -02 Outlet -03 Outlet -04 Outlet -05 Area Served Fitness 345 Fitness 345 Fitness 345 Fitness 345 Fitness 345 Totals: Outlet Size LxW / Design Prelim Final % Final Type D CFM Reading Reading SG SG SG SG SG 12/6 12/6 12/6 12/6 12/6 200 200 200 200 200 1000 180 225 195 225 255 1080 205 210 215 220 215 1065 103 105 108 110 108 107 AIRTEST Co., Inc. TAB Report Page 10 of 15 AIRIEST Co.. Inc. Fan Coil PROJECT: LOCATION: PROJECT #: Marvelle - Sterling Southcenter Tukwila, WA 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: FCU -08 AREA: Yoga 344 Unit Data Unit Manufacturer Unit Model Number Unit Serial Number Carrier FB4CNP025 0319F30869 Test Data Fan Speed Extemal SP Design Med 0.5 in. wc. Electrical Test Data Motor Volts T1-T2 Amps T1 211 Volts 2.1 Amps FCU -08 Supply Outlet Summary Tested By: Mike Kehoe Date: 12/2/2019 Motor Data Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps 1/3 208-230 1 60 Hz 2.8 Amps Sheave Data Drive Type Direct Drive Air Test Data Total Fan CFM Design Total Fan CFM Act. 800 CFM 820 CFM Filter Data Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 AAF Pleated 1 18x20x1 System/Unit Outlet -01 Outlet -02 Outlet -03 Outlet -04 Area Served Yoga 344 Yoga 344 Yoga 344 Yoga 344 Totals: Outlet Size LxW 1 ` Design Type D CFM SG SG SG SG 12/6 12/6 12/6 12/6 200 200 200 200 800 Prelim Reading 110 310 200 165 785 Final Reading 180 210 215 215 820 % Final 90 105 108 108 103 AIRTEST Co., Inc. TAB Report Page 11 of 15 AIRTEST Co., Inc. Fan Coil PROJECT: LOCATION: PROJECT #: Marvelle - Sterling Southcenter Tukwila, WA 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: FCU -09 AREA: Dining 342 Unit Data Unit Manufacturer Unit Model Number Unit Serial Number Carrier FB4CNP036 0419F34976 Test Data Fan Speed Extemal SP Design Med 0.5 in. wc. Electrical Test Data Motor Volts T1-T2 Amps T1 210 Volts 2.8 Amps FCU -09 Supply Outlet Summary Tested By: Mike Kehoe Date: 12/2/2019 Motor Data Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps 1/2 208-230 1 60 Hz 4.1 Amps Sheave Data Drive Type Direct Drive Air Test Data Total Fan CFM Design Total Fan CFM Act. 1200 CFM 1170 CFM Filter Data Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 AAF Pleated 1 18x20x1 System/Unit Outlet -01 Outlet -02 Outlet -03 Outlet -04 Area Served Dining 342 Dining 342 Dining 342 Dining 342 Totals: Outlet Size LxW / Design Prelim Final % Final Type D CFM Reading Reading SG SG SG SG 14/8 14/8 12/6 12/6 400 400 200 200 1200 420 320 190 240 - 1170 390 360 200 220 1170 98 90 100 110 98_. AIRTEST Co., Inc. TAB Report Page 12 of 15 AUTEST Co., Inc. Fan Unit PROJECT: Marvelle - Sterling Southcenter LOCATION: Tukwila, WA PROJECT #: 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: EF -01-02 AREA: Kitchen 120 Unit Manufacturer Model Number Serial Number Fan Type / Class Penn Barry SX115VCGP NA Inline Extemal SP Design 0.5 in. wc Log: Tested By: Mike Kehoe Date: 12/2/2019 Motor Motor Rated Volts Motor Phase Motor Hertz 115 Volts 1 60 Hz Ra Drive Type Direct Drive Test Data Total Fan CFM Des. Total Fan CFM Act. 650 CFM 670 CFM EF -01-02 12/2/2019 Mike Kehoe Fan label is not visible EF -01-02 Exhaust Inlet Summary SYSTEM/UNIT: EF -R-01 AREA: Trash Chute Unit Data Unit Manufacturer Model Number PennBarry DX11B Test Data Extemal SP Design 0.5 in. wc Tested By: Mike Kehoe Date: 12/3/2019 MowCeilD Drive Type Direct Drive Air Test CEtb Total Fan CFM Des. 1000 CFM AIRTEST Co., Inc. TAB Report Page 13 of 15 ( ]R74:' a WI= Q'Ii - 012)(L70 C) Design CFM t;MI D Readin. =I I Readin. Ybl Inlet -01 Kitchen 120 EG 18/18 650 1035 670 103 otals: a o 650 1035 670 UM SYSTEM/UNIT: EF -R-01 AREA: Trash Chute Unit Data Unit Manufacturer Model Number PennBarry DX11B Test Data Extemal SP Design 0.5 in. wc Tested By: Mike Kehoe Date: 12/3/2019 MowCeilD Drive Type Direct Drive Air Test CEtb Total Fan CFM Des. 1000 CFM AIRTEST Co., Inc. TAB Report Page 13 of 15 AIRTEST Fan Unit PROJECT: Marvelle - Sterling Southcenter LOCATION: Tukwila, WA PROJECT #: 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: EF -R-02 AREA: Trash Rooms Unit Manufacturer Model Number PennBarry DX08B Extemal SP Design 0.5 in. wc EF -R-02 Exhaust Inlet Summary Tested By: Mike Kehoe Date: 12/3/2019 1231:u &El Motor HP Motor Rated Volts Motor Phase Motor Hertz 1/4 HP 115 Volts 1 60 Hz mgmaCZga Drive Type Direct Drive Total Fan CFM Des. 650 CFM WM-AM 01:43 Served , Outlet . %/33' ° UnaGAN Ct I esign CFM Prelim Readin.Readin Final n. la s. . Inlet -01 Level 7 EG 6/6 100 140 24/8 650 Inlet -02 Level 6 EG 6/6 100 90 o i Inlet -03 Level 5 EG 6/6 100 100 Inlet -04 Level 4 EG 6/6 100 115 Inlet -05 Level 3 EG 6/6 100 135 Inlet -06 Room 340 EH 10/6 150 145 otas: o o i1J 25 0 0, SYSTEM/UNIT: EF -R-03 66% AREA: Dining 342 Unit Manufacturer Model Number PennBarry DX08B External SP Design 0.5 in. wc EF -R-03 66% Exhaust Inlet Summary Tested By: Mike Kehoe Date: 12/3/2019 Motor I Motor HP Motor Rated Volts Motor Phase Motor Hertz 1/4 HP 115 Volts 1 60 Hz EllmaDlo Drive Type Direct Drive Test Data Total Fan CFM Des. 650 CFM System/Unit Area Served Outlet Size avv / Design CFM Prelim Final Readin. %o FinaI Readin Inlet -01 Dining 342 EG 24/8 650 430 otals: o o i 0 0 AIRTEST Co., /nc. TAB Report Page 14 of 15 A]ERTEST Co., Inc. Fan Unit PROJECT: Marvelle - Sterling Southcenter LOCATION: Tukwila, WA PROJECT #: 19-1058-1 DATE: 12/4/2019 CONTACT: Mike Kehoe AUTHOR: SYSTEM/UNIT: EF -R-04 77% AREA: Fitness Restrooms Unit Manufacturer Model Number PennBarry DX08B Extemal SP Design 0.5 in. wc EF -R-04 77% Exhaust Inlet Summary Tested By: Mike Kehoe Date: 12/3/2019 Drive Type Direct Drive Air Test Data Total Fan CFM Des. 500 CFM SYSTEM/UNIT: SF -01-01 AREA: Kitchen 120 Unit Manufacturer Model Number Fan Type / Class Penn Barry SX115VCGP Inline External SP Design 0.5 in. wc SF -01-01 Supply Outlet Summary Tested By: Mike Kehoe Date: 12/2/2019 'Al Drive Type Direct Drive Test Data Total Fan CFM Des. 650 CFM System/Unit =Served Outlet _ TjED Mraftwitt Design CFM Prelim IIWADED % Finan Readin• Readin. Inlet -01 Men 348 EG 6/6 100 105 84 _ 84 Inlet -02 Men 348 EG 6/6 100 145 91 91 Inlet -03 Women 347 EG 6/6 150 110 118 79 Inlet -04 Women 347 EG 6/6 150 80 94 63 ota s: o o Ku 440 Eafs :: `; W SYSTEM/UNIT: SF -01-01 AREA: Kitchen 120 Unit Manufacturer Model Number Fan Type / Class Penn Barry SX115VCGP Inline External SP Design 0.5 in. wc SF -01-01 Supply Outlet Summary Tested By: Mike Kehoe Date: 12/2/2019 'Al Drive Type Direct Drive Test Data Total Fan CFM Des. 650 CFM System/Unit ATea Served Outlet Size xW / Deign CFM Prelim Final % Finan Readin . Readin. Outlet -01 Kitchen 120 CD 10 RD 325 65 Outlet -02 Kitchen 120 CD 10 RD 325 65 ota s: 0 0 650chi 0 0 AIRTEST Co., Inc. TAB Report Page 15 of 15 COLUMBIA HYDRONICS COMPANY 12828 GATEWAY DR, BLDG 5 • TUKWILA, WA 98168 TELEPHONE 206.241.0500 • FAX 206.241.0520 chchydro.com Letter of Transmittal To: Ocean Park Mechanical Date: 04/15/2019 Attention: Sunny Dhaliwal (sunny@oceanpm.com) PO #: Job: Broadstone Sterling Job #: 18-0479 Location: Tukwila, Washington Quote: Enclosed please find the following items: 1 Set(s) Submittal Data Submittal on CD Other Set(s) IOM Manuals IOM on CD RECEIVED CITY OF TUKWILA APR 1, 9 2019 Notes: Submittal dimensions are approximate. For fabrication pQl3r,UR request certified prints. We require a copy of the approved submittals for our files. If approved submittals are not returned, all equipment will be ordered as submitted. Remarks: Please email to Sunny Dhaliwal (sunny@oceanpm.com). Prepared by: Charlene Bailey CC: Jeff Burpee CHC California Hydronics Corporation CHC Hayward I CHC Columbia I CHC Pacific 1 CHC Reno 1 FlowTherm > C.) /9.401-1,1 n04/ �,a{ • »s � ! � '2 1 1 • � 1 , \ , , J • • A \ 57< •- t ( ( ( ( (��( ( t ( it - % 0000000000 00000000 000.0 00000 GO O /f § \, g. . . _00 0, 01 A4,,-§ P ;--4,,-_0,„ -2 // Tt §\000000p '-(§(">,=(\ ; PROJECT FOLDER ; ` ] ~k[ )(—.- it' as I� �Z , ' . ° * BROADSTONE STERLING - MARVELLE R e ;a / 7 2 ! | 4 )»J g= Ae } m > 5 S! Weatherizing Sealant Sealant 24' Dia. 12- Length 304/Galvolume 24' Dia. 18" Length 304/Golvalume { 24" Dia. Tee Cop 304/Galvalume 1 24"Dia. Adjustable Length 304/Galvalume 24" Dia. Full Angle Ring 439 24" Dia. 36" Length 304/Galvolume 24"Dia. 36" Length No Tool Access Door 304/Galvalume 24" Dia. Anchor Plate Galvanized DESCRIPTION MATERIAL 24" Dia. Sq. to Rnd Adaptor 304/Galvalume 7§|! / 6 '|0 5 -/ \| X°{ ` 2 > C.) /9.401-1,1 n04/ COLUMBIA HYDRONICS COMPANY 1 2828 GATEWAY DR, BLDG 5 • TUKWILA, WA 98168 TELEPHONE 206.241.0500 • FAX 206.241.0520 chchydro.com Letter of Transmittal To: Ocean Park Mechanical Date: 03/19/2019 Attention: PO #: Job: Broadstone Sterling Job #: 18-0479 Location: Tukwila, Washington Quote: Enclosed please find the following items: 1 Set(s) Submittal Data Submittal on CD Other Set(s) IOM Manuals IOM on CD Notes: Submittal dimensions are approximate. For fabrication purposes, please request certified prints. We require a copy of the approved submittals for our files. If approved submittals are not returned, all equipment will be ordered as submitted. Remarks: E1CCCIVCD CITY OF TUKWILA M t �� 020 r PERMIT CENTER MAR201 6 2 MAR 2 6 2019 Prepared by: Charlene Bailey REVISION NO. CC: Jeff Burpee CHC California Hydronics Corporation CHC Hayward I CHC Columbia I CHC Pacific I CHC Reno I FlowTherm REVIEWED FOR CODE COMPLIANCE APPROVED PR 16201 City of Tukwila BUILDING DIVISION "IL.E CO Permit No. id 1I' Plan re; .e.4 approvaltssubfect to errors and omissions Approval of construction aocuments does 'tor. aur me violation of any adopted code or ordinance Re: -..e,:: of approved Fiala Copy and edgea By - li Date 24/5 c.ov of Tukwila HNC. DIVISION REVISIONS No changes snail be made to the scope of work without pr;or approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional pian review. SEPARATE PERMIT REQUIRED FOR: Diu Mechanical 9111 Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION Proposal Project Data Project No: System No: Date: Prepared for: Prepared by: Quote 195-0241 136435 3/15/2019 CHC - California & Columbia Hydronics Marc Whitford Security Chimneys Mike Heavener Project Name: Location: Layout/BOM Title: Product(s): BROADSTONE STERLING - MAVELLE GREASE DUCT WA 19S-0241-1 CIX1-CE(304/Gale) Qty Item No 1 CIX1-24STR0270CE 6 CIX1-24ADL36CE 1 CIX1-24AP 6 CIX1-24FARP 4 CIX1-24L12CE 12 CIX1-24L36CE 1 CIX1-24TCCE 1 CIX1-24LACE 14 S-650 1 S-375 Description 24" Dia. Sq. to Rnd Adaptor N -TOOL ACC DOOR 36" LEN CIX1-36"304-GALV ANCHOR PLATE CIX1-24" FULL ANGLE RING CIX1-24" LENGTH CIX1-24" X 12" 304-GALV LENGTH CIX1-24" X 36" 304-GALV TEE CAP CIX1-24" 304-GALV ADJUST LENGTH CIX1-24" 304-GALV SILICONE PERMATEX 650F SILICONE ALUMINIUM Last revised on 3/15/2019 12:27:04 PM. This quote is valid for 90 days. Security Chimneys International Limited (SCIL) warrants its products are manufactured in accordance with the appropriate UL® standard. Any errors, omissions or required changes to SCIL provided documents or drawings must be noted on the submitted documentation, signed and returned to SCIL to confirm that the revised requirements can and will be met. The venting design is the sole responsibility of the purchaser. All dimensional information, layouts, product specifications and product application must be approved by the purchaser prior to order placement, as indicated by signing a copy of the drawings and returning them to SCIL. Any purchase order received without a signed approval will be considered confirmation that all submitted product information and dimensions are fully approved. The drawings and proposal are the property of Security Chimneys International Limited. This proposal contains a custom part or STR. All orders which contain a custom part will require an additional 5 day added to the current lead- time. Pane 1 of 1 O 92" 10'-52" 10'S" 1'2 1 I 1 1 1 11 4 60' 9" *(ES*(S(I*UI_((t((*(((((T 0©© 0 00 © 0 0 0 0 © © 0 0 0 © 0 0 0© 0 0 00© 0 0000m° N A CO O X < Z DN rC C,___ D a ,o m" o. '0 a,) N_ 3 z 0 a_ — v a o• _ o, _ D n X s^N ' o n n X X N N n (1 n n X X n, — X N N = > > n X P3 D ° n X f D 121 z A PROJECT FOLDER 0A�_ `'° o9Ao3o�n m m m m v m N o m 1� • t 2 � 1 BROADSTONE STERLING - MARVELLE -- oFF?�T�pzj r£ o�n �Omo r_ of 24" Dia. Anchor Plate Gale 24" Dia. Full Angle Ring 4 24" Dia. 12" Length 304/Gc 24' Dia. 36. Length 304/G 24" Dia. Tee Cap 304/G 24' Dia. Adjustable Length 304/G Sealant Weatherizing Sealant DESCRIPTION MATERIAL 24' Dia. Sq. to Rnd Adaptor, 30"x12" 304/Gc 36' Length No Tool Access Door 304/Gc ;sg. lJ� SC i1, Q.:o 1 >opNo£N c rN3 Nc i ;mJNA a R -2`x Fa aIvalume aIvalume 0 p 3 m aIvalume aIvolume D CO } li 0 Secure7SThcRro Modular Double Wall Positive Pressure Chimney Boiler Breeching; Stack and Engine Exhaust V Grease Duct. www.securitychimneys.com 800-361-4909 (US) 800-667-3387 (Canada) Secure Stack® Pro The Secure Stack® Pro Series, Models CAX1, CIX1, CIX2, and CIX4 venting systems are designed to offer the ultimate in installation convenience and versatility for a variety of applications. Certified for commercial chimney, boiler breeching & stack, diesel exhaust, and Grease Duct applications. Thick -gauge material for the inner pipe and coupling provides a strong and rigid assembly. Self -centering flue extension significantly simplifies and accelerates the installation process. ATRADITION OF EXCELLENCE For over 50 years, Security Chimneys has been an innovator in the venting field and a market leader in North America. Instrumental in the company's growth has been an ongoing focus on product improvement and the introduction of new, innovative products. The Secure Stack Pro venting systems are prime examples of our constant quest for more cost- effective, versatile and reliable product solutions. DESIGNED WITH PERFORMANCE IN MIND Available in sizes from 5" to 36" diameters, the CIX models offer a choice of 1", 2", or 4" insulated double wall chimneys, and the CAX1 offers a 1" air insulated product. For premium corrosion resistance and durability, the inner flue is constructed from 0.035" thick 304 or 316 Stainless Steel. This is coupled with a 0.024" thick 304 Stainless Steel or Galvalume (Aluminum -zinc coated) steel outer casing. CIX models are is lined with the highest -quality AES Wool insulation, densely packed to ensure low heat loss, maximum draft, and the lowest clearance to combustible materials. C LISTED MH 10971 MH 45179 LISTED TO STANDARDS: UL 103 US UL 103HT ULC C604 ULC C959 UL 1978 CAN/ULC S662 UL 2561 - except SCL 2 Security Chimneys 1 www.securitychimneys.com SECURITY CHIMNEYS SECURE STACK® PRO/' A POSITIVE PRESSURESYSTEV The Secure Stack® Pro Series Difference: Features Self -centering Benefits • Components line up easily and quickly • Fast and efficient installations Thinner -gauge material on outside casing • Lower weight • Easier to install REFRACTORY AES WOOL INSULATION Security Chimneys understands the needs of the industry and is always pushing the design envelope to embrace new technologies. With our dedicated effort to offer the best performing products, Secure Stack Pro Series utilizes Refractory Alkaline Earth Silicate (AES) Wool Insulation. AES Wool displaces the old "ceramic fiber" type insulations many manufacturers are still using today. The AES Wool featured in our products meets the requirements requested under NOTA Q and are exonerated from classification and labelling regulation in Europe. When compared to ceramic fiber, AES Wool insulation offers: • Approximately 80% lower Biopersistance* half-life • Superior thermal insulation properties • Improved tensile strength, compression & resilience • Increased energy efficiency, leading to significant weight and cost savings 'Biopersistance is the ability of fibers to resist removal from the lungs by natural mechanisms (i.e., dissolution and breakage). Ceramic fiber insulation is classified as a Class 2 Carcinogen in the European Union and classified as a possible carcinogen in the United States and Canada. 350 E' 3 300 I250 200 S 150 E 000 Y '50 Estimated Maximum Outer Pipe Temperature Rise above Ambient Temperature (0F) 0s' • 036' 036• Model CIX1 05' 036' Model CIX2 05• 036' Model CIX4 05• 0 100 200 300 400 500 600 700 690 900 1000 1100 1290 1300 1400 flue Gas Temperature Rise CT Above Ambient) 800-361-4909 (US) 1 800-667-3387 (Canada) 3 L24 BSEK L36 TPFKE( GDRT(GD Selection guide TYPICAL Clearance to Combustible (Unenclosed Surrounding) (from the outer band) Grease Duct - UL 1978 (500°F) 18 18 18 18 18 18 18 18 18 18 18. 18 18 18 18 2 18 4 2 18 4 2 18 4 3 18 4 [ 3 18 5 3 18 Dimensions are in inches Note: Clearance to non combustible is 0" for all models and diameter 6 Security Chimneys 1 www.securitychimneys.com DUCT INSTALLATION Minimun Air Space CLEARANCE to Unenclosed Combustible Surroundings (adjacent to maximum of two walls). Building Heating Appliance ,8( 1400°F Chimney Flue Diameter 0 (n) CIX2 & CIX4 103 Type HT 05 to 024 Can Dimensions are in inches 'Building heating appliance only 05 to 036 05 to 06 07to014 016 to 022 024 to 030 032 to 036 05 to 06 07 to 014 016 to 022 024 to 030 032 to 036 05 to 014 016 to 030 032 to 036 Clearance to Combustible (in) 18 4 5 6 7 8 1 2 3 Clearance to Non -Combustible 0 0 0 0 0 0 0 0 0 4 0 5 1 2 3 1 0 0 0 0 Engineering section The term 'Pressure Stack' typically refers to positive pressure chimneys that can be used for boiler breeching and stack, as well as diesel and turbine exhaust, building heating equipment, industrial furnaces, processing equipment, kilns and ovens, and other heavy duty applications with high temperature exhaust requirements. In the United States, factory built chimneys are intended for use in accordance with NFPA 211, the Standard for Chimneys, Fireplaces, Vents, and Solid -Fuel Burning Appliances, and in accordance with models codes such as the International Mechanical Code, the International Residential Code, and the Uniform Mechanical Code. In Canada, factory built chimneys are intended for use in accordance with the National Building Code of Canada, Installation Code for Oil Burning Equipment, CAN/CSA-B139, and for Gas Burning Equipment, CAN/CGA-B149.1 and CAN/CGA-B149.2. Factory built chimneys are designed, tested, and certified for installation inside or outside of buildings, or both, to transport flue gases to the outside. Security Chimneys Secure Stack Pro series of modular double-wall positive pressure venting systems have been designed and engineered to not only meet, but exceed the rigorous requirements of many test standards Below is a brief summary of the standards that Secure Stack Pro was tested and certified under. For more details about the specifics of our Underwrites Laboratories (UL) product listings,.consult the UL Online Certifications Directory. UL 103 BUILDING HEATING APPLIANCE CHIMNEY LISTING: Under this category, models SCL, CAX1, CIX1, CIX2, and CIX4 have been determined suitable for venting flue gases at temperatures not exceeding 538°c (1000°f) under continuous operating conditions from gas, liquid, oil or solid fuel fired appliances. Also complies with operation (less than one hour) at temperatures not exceeding 740°c (1400°f) and brief operation (maximum 10 minutes) at temperatures not exceeding 906°c (1700°f). Building heating appliance chimneys are suitable for use with building heating appliances and low heat appliances as described in the chimney selection chart of national fire protection association (nfpa) standard no. 211. UL-103(HT) - STANDARD FOR FACTORY -BUILT CHIMNEYS FOR RESIDENTIAL TYPE AND BUILDING HEATING APPLIANCES The UL -103 standard applies to factory -built chimneys intended for venting gas, liquid, and solid -fuel fired residential -type appliances and building heating appliances in which the maximum continuous flue -gas outlet temperatures do not exceed 1000°F (538°C). Tests included in this standard are designed to test the structural and thermal properties of the chimney and includes tests such as the Thermal Shock Test, Temperature Test (at 1000°F, 1400°F, 1700°F, and if required 2100°F). In order to qualify for the UL-103HT listing, a chimney that is tested under the UL -103 standard must successfully complete the requirements of the 2100°F (1149°C) Flue Gases Temperature Test, conducted 3 times. After being subjected to the tests listed, as applicable, a chimney shall be capable of being used further. The following results indicate compliance: 800-361-4909 (US) 800-667-3387 (Canada) 7 Engineering section • No part of the chimney has become damaged or permanently distorted to an extent that it or the chimney assembly does not continue to function as intended. • The effectiveness of any required protective coating or finish on metal parts has not been reduced. • A ceramic material shows no evidence of cracking, disintegration, or spalling to the extent that serviceability of any part of an assembly has been impaired. • Cracks are not observable in porcelain enamel used as a required protective coating when the surface is examined under a microscope of 60 magnification. • The reflectivity of a surface has not been impaired when the reflectivity is utilized to reduce the risk of fire. • Burning or scaling of metal parts is not evident upon visual observation. • The effectiveness of insulating material has not been reduced. Additional tests included in this standard are the Positive Pressure Applications Test, Draft Test, Vertical Support Test, Strength Tests (Impact, Longitudinal Force, Load Test for Chimney Elbows, Joint Load, and Joint Torsion Test), Wind Load Test, Rain Test, and other tests related to the components used in the chimney construction. UL -2561 - STANDARD FOR 1400 DEGREE FAHRENHEIT FACTORY -BUILT CHIMNEYS This standard applies to factory -built 1400 degree Fahrenheit chimneys intended for venting gas, liquid, and solid -fuel -fired appliances in which the maximum continuous flue -gas temperatures do not exceed 1400°F (760°C). Similar in nature to UL-103(HT), this standard covers many of the same tests designed to test the structural and thermal properties of the chimney. UL -2561 is intended for chimneys that will be used in a more industrial application where flue gas exhaust temperatures are higher, and therefore includes a Temperature Test at 1400°F and 1800°F. ULC -C604 - STANDARD FOR FACTORY -BUILT TYPE A CHIMNEYS This standard applies to Factory -Built Type 'A' Chimneys which do not require field fabrication. They are for use with gas and liquid fuel -fired residential appliances and building heating equipment, where the appliance or equipment flue -gas temperatures do not exceed 540°C. They are intended for use in accordance with the National Building Code of Canada, Installation Code for Oil Burning Equipment, CAN/CSA-B139, and for Gas Burning Equipment, CAN/CGA-B149.1 and CAN/CGA-B149.2. Tests included in this standard are designed to test the structural and thermal properties of the chimney and includes tests such as the Thermal Shock Test, Temperature Test (at 540°C and 760°C), Soot Burnout, Draft Test, Support Test, Strength Test, Wind Load Test, and other tests related to the components used in the chimney construction. ULC/ORD-C959 - CHIMNEYS, INDUSTRIAL 540°C AND 760°C This standard applies to Factory -Built industrial chimneys intended for use with certain process equipment and large oil or gas burning building heating appliances normally producing flue gas temperatures of 540°C or 760°C, or less as applicable. Tests included in this standard are designed to test the structural and thermal properties of the chimney and include more stringent tests compared to ULC -C604, including the Thermal Shock Test, Temperature Test (at 540°C and 760°C, and if applicable 925°C and 980°C), Support Test, Strength Test, Wind Load Test, and other tests related to the components used in the chimney construction. UL 1978 — STANDARDS FOR GREASE DUCTS This standard applies to factory -built grease ducts, and grease duct assemblies that are intended to be installed at reduced clearances where 18 inch clearance is specified in NFPA 96 and the International Mechanical Code. These requirements also cover modular grease duct assemblies, unwelded connections between adjoining duct parts, fittings, access doors, and the like intended for use with grease ducts installed in accordance with NFPA 96 and the International Mechanical Code. 8 Security Chimneys 1 www.securitychimneys.com Engineering section Security single wall and double wall model venting systems are Listed by Underwriters Laboratories, Inc. (UL) in the following product categories and in the diameters indicated: Model SCL (Single wall) UL 103 - Building Heating Appliance Chimney 5"- 36" ID UL 1978 - Grease Duct ULC 5662 - Grease Duct 5"- 36" ID Model CAX1 (Double wall, 1" air insulation) UL 103 - Building Heating Appliance Chimney 5"- 36" ID UL 2561 - 1400° Fahrenheit Chimney 5"- 36" ID UL 1978 - Grease Duct ULC 5662 - Grease Duct 5"- 36" ID Model CIX1, CIX2, CIX4 (Double wall, fiber insulation) UL 103 - Building Heating Appliance Chimney 5"- 36" ID UL 103 HT - Building Heating Appliance Chimney(Type HT) 5"- 24" ID UL 2561 - 1400° Fahrenheit Chimney 5"- 36" ID UL 1978 - Grease Duct ULC S662 - Grease Duct 5"- 36" ID ADDITIONAL APPLICATIONS Models SCL, CAX1, CIX1, CIX2, and CIX4 are also suitable for negative, neutral or positive pressure pre -fabricated piping systems intended for use in a variety of applications including but not limited to the following: Fume Venting, Chutes, Particle Conveying, Dryer Vents and Ventilation Ducts. MIXING PARTS Model SCL, CAX1, CIX1, CIX2, CIX4 and CIX3Z may be intermixed within a system, assuming proper clearances are maintained for respective components. When penetrating a roof, appropriate roof penetration components must be used. Do not use Model SCL to penetrate through a wall, floor or roof. Security Models SCL, CAX1, CIX1, CIX2, and CIX4 chimneys may penetrate a combustible floor, wall, or roof using the appropriate parts and openings sizes. NOTE: Do not enclose with combustible materials In the case of a fire rated enclosure made of non-combustible or limited combustible construction, the minimum clearance with the Model SCL must be 6" or as required by local code. 800-361-4909 (US) 800-667-3387 (Canada) 9 Lengths Length (L12, L18, L24, L36) Used as standard duct lengths. Available in sizes from 5' to 36". Included: For SCL One (1) Locking Inner "V" Band (BSI), and one (1) Centering Flue Extension (PR -C0794). For CAP: One (1) Locking Inner "V" Band (BSI), one (1) Centering Flue Extension (PR -C0794), and one (1) Outer Band (BSE). ForCIX1, CIX2, and CIX4: One (1) Locking Inner "V" Band (BSS, one (1) Centering Flue Extension (PR -C0794), one (1)6" insula- tion 1)6"insula- tion band, and one (1) Outer Band (BSE). CENTERING FLUE EXTENSION 21 /4 I Effective FLOW Gas , Length 21/4 1 CI CD Ilia SCL (Single Wall) CAX1 (1" air) /CIX1 (1" Wool Insulated) CIX2 (2' Wool Insulated) CIX4 (4" Wool Insulated) Length (in) (0B) O.D. Product Code 69 08 U Product Code Code Product Code (Q DOD (O0.0 )Product 05" to 036" L12 11 5/8" -- SCL0L12 CAX1-0L12 �( CIX1-0L12 1 CIX2-0L12 CIX4-0L12 05" to 036" L18 17 5/8" SCL0L18 0+2" CAX1-0L18 CIX1-0L18 0+4" CAX1-0L24 CIX1-0L24 CIX2-0L18 CIX4-0L18 0+8" CIX2-0L24 CIX4-0L24 05"to 036" L24 0 24 1/8" SCL0L24 05"to 036" L36 36 1/8" I SCLOL36 CAX1-0L36 CIX1-0L36 I CIX2-0L36 CIX4-0L36 Material options (Inner -Outer): 304-Galvalume, 304-304, 316-Galvalume, 316-304 Flow resistance: 05" to 016": K = 0.4 (eff. length [ft] / 0 [in]) 018" to 036": K = 0.3 (eff. length [ft] / 0 [in]) For Engine and Turbine Exhausts: K = 0.25 (eff. length [ft) / 0 [in]) Adjustable Lengths (LA) Used to adjust to fit odd dimensions and compensate for thermal expansion. Suitable for application on low positive pressure system with less than 1' water column. Included: For SCL: One (1) Locking Inner "V" Band (BSI), one (1) Graphite packing kit on a inner liner, a special tool for proper installation of Graphite packing, and hardware. ForCAX1: One (1) Locking Inner "V" Band (BSO, one (1) Graphite packing kit on a inner liner, a special tool for proper installation of Graphite packing, two half casing, and hardware. For CIX1, CIX2, and CIX4: One (1) Locking Inner "V" Band (BSI), one (1) Graphite packing kit on an inner liner, a special tool for proper installation of Graphite packing, two hall casing, insulation pad, and hardware. Mita Length (in.) CAX1 Product Code (Single Wall) I I 1 05" to 036" 71/4" to 28 3/8° SCLOLA CAX1-0LA CIX1-0LA Material options (Inner -Outer): 304-Galvalume, 304-304, 316-Galvalume, 316-30 Flow resistance: 05" to 016": K = 0.4 (eff. length [ft] / 0 [in]) 018° to 036": K = 0.3 (eff. length [ft] / 0 [in]) For Engine and Turbine Exhausts: K = 0.25 (eff. length [ft] / 0 [in]) (1" insulated) (2" insulated) CIX4 (4" insulated) CIX2-0LA CIX4-0LA Effective Length Variable Lengths (LV) Used to adjust to fit odd dimensions. Not used for thermal expansion. Can be used in positive pressure applications. Included: For SCL: One (1) Locking Inner "V" Band (BSI), one (1) collar kit on the inner liner with a special locking band (BS), and hardware. For CAX1: One (1) Locking Inner "V" Band (BSI), one (1) collar kit on the inner liner with a special locking band (BS), two hall casing, and hardware. For CIXI, CIX2, and CIX4: One (1) Locking Inner "V" Band (BSO, one (1) collar kit on the inner liner with a special locking band (BS), two half casing, insulation pad, and hardware. 0 31/0 Map Length (in.) Product Code (Single Wall) I CAX1 (1" insulated) (2" insulated) CIX4 (4" insulated) ' 05" to 036" 7" to 281/2" SCLOLV CAX1-0LV CIX1-0LV Material options (Inner -Outer): 304-Galvalume, 304-304, 316-Galvalume, 316-304 Flow resistance: 05° to 016°: K = 0.4 (eff. length [ft] / 0 [in]) 018" to 036": K = 0.3 (eff. length [ft] / 0 [in]) For Engine and Turbine Exhausts: K = 0.25 (eff. length [ft] / 0 [in]) CIX2-OLV CIX4-0LV Effective Length 800-361-4909 (US) 1800-667-3387 (Canada) 11 Tee Accessories /Access Tee Cap (TC) Used to close, seal or provide access for cleanout unused tee ports. Included. For SCL: One (1) disc with handle, and one (1) SMALL Locking Inner "V" Band (BSI). For CAX1: One (1) disc with handle, one (1) SMALLER Locking Inner "V" Band (BSI), one (1) LARGER Locking Inner "V" Band, and one (1) outer bucket -casing with handles. For CIX1, CIX2, and CIX4: One (1) disc with handle, one (1) SMALLER Locking Inner "V" Band (BSI), one (1) LARGER Locking Inner "V" Band, one (1) outer bucket -casing with handles, one (1) (CIX1, CIX2) or two (2) (CIX4) round Insulated pad, and one (1) insulation wrap. 0— Milkimiiiiiiiion i TOTAL EFFECTIVE LENGTH vow LENGTH SCL (Sing! Wall) CAX1 (1"Air Insulated) /CIX1 (1" Wool Insulated) CIX2 (2" Wool Insulated) CIX4 (4" Wool Insulated) Q MD me eaD I Length (in) Product Code U2n �} n 5 1/2 MVO Length (in) 2 3/4 Praduct CAX1-0TC Code CIX1-0TC CEO © 61/2 OM Length (in) 3 3/4 Product Code I CIX2-0TC ZED Op er» 81/2 1311=0 Length (in) 5 3/4 Product Code CIX4-0TC I I 5" to 36" I4111—I 1 SCLOTC Material options (Inner -Outer): 304-Galvalume, 304-304, 316-Galvalume, 316-304 Drain Tee Cap (DTC) Used to close and seal unused tee ports and to provide dram point for condensation at the base of a vertical duct run. 1" NPT nipple. Included: For SCL : One (1) disc with a 1" NPT nipple and one (1) SMALL Locking Inner "V" Band (BSI). For CAX1: One (1) disc with a 1" NPT, one (1) SMALLER Locking Inner "V" Band (BSI), one (1) LARGER Locking Inner "V" Band, and one (1) outer bucket -casing with handles. For CIX1, CIX2, and CIX4: One (1) disc with a 1" NPT, one (1) SMALLER Locking Inner "V" Band (BSI), one (1) LARGER Locking Inner "V" Band, one (1) outer bucket -casing with Handles, one (1) (CIX1 and CIX2) or two (2) (CIX4 only) round Insulated pad, and one (1) insulation wrap. TOTAL EFFECTIVE LENGTH LENGTH DO SCL (Single Wall) CAX1 (1"Air Insulated) /CIX1 (1" Wool Insulated) CIX2 (2" Wool I sulated) CIX4 (4" Wool Insulated) Length (in) Length (in) Praduct Code MI Length (in) IBM� lyy {�;�y atiD Product Code Length (in) Length (in) Product Cade Length (in) Length (in) Product Code 5" to 36" I 2 2 I SCLODTC I 5 1/2 I 3 I CAX1-0DTC p CAX1-0DTC 61/2 4 CIX2-0DTC 81/2 I 6 I CIX4-0DTC Material options (Inner -Outer): 304-Galvalume, 304-304, 316-Galvalume, 316-304 800-361-4909(US) 1 800-667-3387 (Canada) 31 Connections - Starting Adaptors Square to Round (STRAB) or Round to Square (RTSAB), where "A" & "B" are the square dimensions Used to connect a round chimney to a square/rectangular connection and vice versa. The square dimension is designed to be connected by means of lap of weld on the field. These parts are always considered custom parts. NOTE: ALL DIMENSIONS DATA MUST BE ANALYSED AND APPROVED BY SECURITY CHIMNEYS TECHNICAL SUPPORT BEFORE ORDERING. Dimensional data to specify : - the exact size of the outer dimensions of the square or rectangular (A" x B") ; - the diameter of the round end (i.e. the SCL, CAX1, CIX1, CIX2, and CIX4 flue dimension); - the effective height; - the flange dimension on the square or rectangular end if not 1 1/2"; - the option of the square flange: • Option #1 = a 1" Flue extension on the square/rectangle side, • Option #2 = No flue Extension on the square/rectanglular side. NOTE: Standard dimensions will be as follow: - Option #1 - Effective length = 20" - 1 1/2" wide flange on the square/rectangular. Included: For SCL: One (1) Locking Inner "V" Band (BSI), one (1) Centering Flue Extension (PR -C0794). For CM: One (1) Locking Inner "V" Band (BSA one (1) Centering Flue Extension (PR -C0794), and one (1) Outer Band (BSE). For CIX1, CIX2 and CIX4: One(1) Locking Inner "V" Band (BSI), one (1) Centering Flue Extension (PR -C0794), one (1) 6"insulation band, and one (1) Outer Band (BSE). Sidenew Option Sq®" Flange al I 07 SideVew Option Square Flange" I 0 I 0 Length (in) Square Dimensions Offset Dimensions Product Code MI gal » ORD Option ® (Single`) CAX1 (11Air Insulated) g (1" Insulated) ® (2 ,Insulated) CIX4 (4 Insulated) I SCLOSTRAB CAXI OSTRAB CIX1 OSTRA6 #1 or #2 CIX2 OSTRA6 CIX4-0STRA6 5" to 36" 20" or Custom Custom ( Custom SCLORTSAB CAX1-ORTSAB CIX1-0RTSAB CIX2-ORTSAB CIX4-ORTSAB Material options (Inner -Outer): 304-Galvalume, 304-304, 316-Galvalume, 316-304 Flow resistance: K = unknown (custom) Eccentric Square to Round (CUSTOM) or Eccentric Round to Square (CUSTOM), where "A" & "B" are the square dimensions and the "C" and "D" is the offset of the round part. It is similar to a STR except the round collar is offset from center of the square collar. Same used as the STR, but can have a flat bottom on horizontal runs or provide an offset (C X D). The square dimension is designed to be connected by means of lap of weld on the field. NOTE: ALL DIMENSIONS DATA MUST BE ANALYSED AND APPROUVED BY SECURITY CHIMNEY TECHNICAL SUPPORTS BEFORE ORDERING. Dimensional data to specify : - the exact size of the outer dimensions of the square or rectangular (A" x B"); - Specify the offset dimensions C" x D" refered to one outer side of the square and the center of the round end; - the diameter of the round end (i.e. the SCL, CAX PRO or CIX PRO flue dimension); - the effective height;. - the flange dimension on the square or rectangular end if not 1 1/2"; - the option of the square flange: • Option #1 = a 1" Flue extension on the square/rectangle side, • Option #2 = No flue Extension on the square/rectanglular side. Included: For SCL: One (1) Locking Inner "V" Band (BSI), one (1) Centering Rue Extension (PR -C0794). ForCAX1: One (1) Locking Inner °V" Band (BSI), one (1) Centering Flue Extension (PR -C0794), and one (1) Outer Band (BSE). For CIX1, CIX2 and CIX4: One(1) Locking Inner °V" Band (BSI), one (1) Centering Flue Extension (PR -C0794), one (1)6" insulation band, and one (1) Outer Band (BSE). SideVew Option Square Flange II U Z w 'i SideVew Option Square Range $2 r 0 m ii/ I `\ �, ``` CzD • Alin _ 11/2 AaB ,_ Ay j 0 Length (in) Dimensions Offset Dimensions Option Product Code (from the center)erati alto SCL (Single Wall) CAX1 (1"Air Insulated) CIX1 (1" Insulated) CIX2 (2" Insulated) CIX4 (4" Insulated) 5"" to 36" I Custom 1 1 Custom j Custom i Custom Custom #1 or #2 j Custom Custom Custom Custom Custom Custom Custom Custom Custom Custom Material options (Inner -Outer): 304-Galvalume, 304-304, 316-Galvalume, 316-304 Flow resistance: K = unknown (custom) 36 Security Chimneys 1 www.securitychimneys.com Supports Full Angle Ring (FAR) Used for support on horizontal runs or for guiding on vertical runs. See installation instructions for spacing. Effective Length = 0'. Same dimensions as the Half Angle Ring (HAR). Included: ForSCL, CAX1, CIX1, CIX2, and CIX4: Two (2) HalfAngle Ring (HAR), and hardware to join both Haff Angle Rings. Hardware for connection to structure is not included (by others). II - c +—'-- D i+1 DJ °J-0A.(z°c)--' 1.1 aria _(23 OB � @ 1:021) t O a CI01{ MID 0' CIX4 (4" Wool Insulated) per half) Product Code ® (Single Wall) CAX1 (1" Air Insulated) ® (1" Insulated) ® (2" Insulated) CIX4 (4" Insulated) See HAR I See HAR I See HAR I See HAR I See HAR See HAR See HAR SCLOFAR CAX1-0FAR CIX1-0FAR CIX2-0FAR CIX4-0FAR Material options (angle): - 05 to 010 = 304, 011 10 044 = 439 Anchor Plate (AP) Used for supporting the Chimney in vertical or horizontal runs and to provide a fixed point for thermal expansion consideration. The square opening of the frame must be a minimum of 0.D. + 3/4° or a maximum of 0.D. + 3 1/4'. Effective Length = 0° Must not be in contact with combustible materials. Included: For SCL' Four (4) Split Square plates, lour (4) clamps nng, and hardware included. For CAX1: Four (4) Split Square plates, four (4) damps ring, two (2) half outer band (DBSE), and hardware included. ForCIXI, CIX2 and CIX4: Four (4) Split Square plates, four (4) damps ring, two (2) Haif OuterSand (DBSE) with two (2) 3" insulation bands, and hardware included. Hardware for connection to structure is not included (by others). C 3/4 3/4 —1 0 OA SCL (Single Wall) - CAX1 (1"Air Insulated) - CIX1 (1" Wool Insulated) CIX2 (2' Wool Insulated) CIX4 (4" Wool Insulated) OB (NM 09 4 OW Product Code OB Product Code OB Ca Product Code ® (Single ll) CAX1 (1" Ai Insulated) ®ate (1 Insulated) 0 ® (2j)nsulated) CIX4 (4Ylnsul1ed) 5 51/2 81/2 13 SCL5AP SCL6AP SCL7AP SCL8AP SCL9AP SCLIOAP SCL11AP CAX1-5AP CAX1-6AP CAX1-7AP CAX1-8AP CAX1-9AP CAX1-10AP CAX1-11AP CAX1-12AP CAX1-13AP CAX1-14AP CAX1-16AP CAX1-18AP CAX1-20AP CAX1-22AP CAX1-24AP CAX1-26AP CAX1-28AP CAX1-30AP CAX1-32AP CAXI-34AP CAX1-36AP CIX1-5AP CIX1-6AP CIX1-7AP CIX1-8AP CIX1-9AP CIX1-10AP CIX1-11AP CIX1-12AP CIX1-13AP CIX1-14AP CIX1-16AP CIX1-18AP CIX1-20AP CIX1-22AP 101/2 15 CIX2-5AP CIX2-6AP 15 19 CIX4-5AP CIX4-6AP CIX4-7AP CIX4-8AP CIX4-9AP CIX4-10AP CIX4-11AP CIX4-12AP CIX4-13AP CIX4-14AP CIX4-16AP CIX4-18AP CIX4-20AP CIX4-22AP CIX4-24AP CIX4-26AP CIX4-28AP CIX4-30AP CIX4-32AP CIX4-34AP CIX4-36AP 6 61/2 91/2 14 111/2 16 16 20 7 7 1/2 10 5/8 15 13 17 CIX2-7AP CIX2-8AP CIX2-9AP CIX2-10AP CIX2-11AP 17 21 8 8 1/2 11 1/2 16 14 18 18 22 9 91/2 12 3/4 17 15 19 1 3/4 23 10 101/2 1313/16 18 16 20 13/4 24 11 111/2 15 19 17 21 13/4 25 12 121/2 16 20 SCL12AP SCL13AP SCL14AP SCL16AP SCL18AP SCL20AP i, SCL22AP SCL24AP SCL26AP SCL28AP SCL30AP SCL32AP SCL34AP SCL36AP 18 22 CIX2-12AP CIX2-13AP CIX2-14AP CIX2-16AP .. - CIX2-18AP CIX2-20AP CIX2-22AP CIX2-24AP CIX2-26AP CIX2-28AP CIX2-30AP CIX2-32AP CIX2-34AP CIX2-36AP 13/4 26 13 131/2 17 21 13/4 23 13/4 27 14 141/2 18 22 13/4 24 13/4 28 16 161/2 193/4 24 _ .--4 26 13/4 --- --------. 13/4 26 28 13/4 30 18 181/2 213/4 283/8 32 20 201/2 23 3/4 28 1 3/4 30 30 3/8 34 22 221/2 25 3/4 30 28 3/8 32 32 3/8 36 I24 24 1/2 28 3/8 32 i CIX1-24AP 30 3/8 34 34 3/8 38 26 26 1/2 30 3/8 34 CIX1-26AP CIX1-28AP CIX1-30AP CIX1-32AP CIX1-34AP CIX1-36AP 32 3/8 36 36 3/8 40 28 281/2 32 3/8 36 34 3/8 38 38 3/8 40 3/8 42 30 30 1/2 34 3/8 38 36 3/8 40 44 32 34 321/2 36 3/8 40 38 3/8 40 3/8 42 44 46 42 3/8 44 3/8 46 3/8 46 34 1/2 38 3/8 42 44 48 50 36 361/2 40 3/8 42 3/8 Material options (plates): 439, Galvanized 800-361-4909(US) 1 800-667-3387 (Canada) 39 Joint Assembly - Replacement Parts Duct Closure Band (CR) Use to shield insulation from weather for some Single Wall Termination (Conic Rain Cap, No loss Cap, Flip Top) or when transition from CAX1, CIX1, CIX2, CIX4 to SCL on vertical run. Hardware provided. Included: ForCAX1, CIX1, CIX2, and CIX4: One (1) collar and hardware. 0 -05" 0A 08 atip Length (in) Produ Product Code Length (in) Eag ( r) a lr0 (1" insulated) 13® (2insulated) CIX4 (4" insulated) II to 036" 0 + 1/16 100.0. +4" I 7" I 0° CAX1-OCR I CIX1-OCR CIX2-0CR CIX4-OCR Materials available: Galvalume, 304 Transition Outer Band (O.D. from one lineup to another) Used to shield insulation on vertical or horizontal run when there is a transition from any product lineup to another one. Each product can be used on both ways: to convert up to a larger outer wall, or to convert up to a smaller outer wall. Included: For SCL, CAX1, CIX1, CIX2 and CIX4: Two (2) half bands with hal/ disc, and hardware. 0 00 0 of band Lengthg (in) DM (Tube per outer Joint for exterior weathering) Produ tCode One (1)lineup gap r r +2or0.D'*2) Two (2) lineup gap r r +4or0.D.-4) Three (3) lineup gap r r +6or0.D.-6) Four(4) lineup gap r r +8 or0.0.-8) Length (in) 05" to 036" 00.D. + 3/4 5 3/8" 0" SCLOCAX1 CAX1-0CIX2 CIX1-0C1X2 SCLOCIX2 I CAX1-0CIX4 SCL0CIX4 CIX2 0CIX4 CIX1-0CIX4 Sealant �-- + 3/4 --- The S-375 grey sealant is used if any joints of any bands are exposed to weather, or on other parts that are external the structure and need to be sealed. The S-650 red sealant is used for Flange to Flange Joint Assembly for a maximum continuous flue temperature of 650°F. The S-2000 white sealant is used for Flange to Flange Joint Assembly for a maximum continuous flue temperature of 2000°F. 58 Security Chimneys 1 www.securitychimneys.com Expected number of tubes per joint/hole for each sealant Flue Diameter 0 DM (Tube per outer Joint for exterior weathering) S-650 and S-2000 (Tube per Joint Assembly) 5 1/5 1/5 6 1/5 1/5 7 1/5 1/5 8 1/5 1/5 9 1/5 1/5 10 1/5 1/5 11 1/4 1/4 12 1/4 1/4 13 14 1/4 1/4 1/4 1/4 16 18 1/4 1/3 1/4 1/3 20 22 1/3 1/3 1/3 1/3 24 1/2 1/2 26 1/2 1/2 28 1/2 1/2 30 2/3 2/3 32 2/3 2/3 34 3/4 3/4 36 3/4 3/4 Grease Duct Accessories No Tool Inline Access Door Used for inspection and cleaning. Greaseproof and fire -tight seal. Included: For SCL• One (1) Locking Inner "V" Band (BSI), one (1) Centering Flue Extension (PR - 00794), one (1) fiber high temperature gasket, one (1) silicone gasket, one (1) inner door, and hardware (wing screws) for the access door. Replacement gaskets available For CAX1, C1X1, CIX2, and CIX4: One (1) Locking Inner "V" Band (BSI), one (1) Centering Flue Extension (PR -C0794), one (1) locking outer band (BSE), one (1) fiber high temperature gasket, one (1) silicone gasket, one (1) inner door, one (1) outer door and hardware (wing screws) for both access doors. O (NO pato 1212113Product OGICD ► Code Qs, (Single Wall) CAX1 (1:Airinsulated) l7® (1" Insulated) ® (2" Insulated) Imo! (4"Insulated) 1 05" to 036" 26 26 3/8 SCL0ADL26 ' CAX1-0ADL26 SCL0ADL36 CAX1-0ADL36 CIX1-0ADL26 CIX2-0A01.26 CIX4-0ADL26 CIX2-0ADL36 CIX4-0ADL36 05" to 036" 36 361/16 CIX1-0ADL36 Materials available: 304, 316. Flow resistance: K = .30 (eff.length [ft] / 0 fin]). 90° Tees and 90° Tees with a Dam Used to change direction at 90° breeching. Can be used as an inspection access in horizontal runs. An optional Dam can be ordered in position 11 or 12 for protection against fluids running out while cleaning. Included: ForSCL: One (1) Locking Inner "V" Band (BSI) and one (1) Centering Flue Extension (PR -C0794). For CAX1, CIX1, CIX2, and CIX4: One (1) Locking Inner "V" Band (BSI), one (1) Centering Flue Extension (PR -C0794) and one (1) Locking Outer Band (BSE). 0 Gilnu 0 Om 1 Standard Option 01 Or 02 0 lid 1 Standard Option 01 Or D2 5' 121/16" 0" 61/32" 61/32" SCL5T90 1 SCL5T90D1 or 2 18° 251/16" 0° 1217/32° 1217/32° SCL18T90 SCL18T90D1 or 2 ~ 6" 13 1/16" 0" 6 17/32° 6 17/32" SCL6T90 . SCL6T90D1 or 2 20" 271/16" 0° 1317/32" 13 17/32"SCL2OT90 SCL20T90D1 or 2 7" 14 1/16' 0° 71/32" 71/32" SCL7T90 { SCL7T90D1 or 2 22" 291/16" 0° 1417/32" 1417/32" SCL22T90 SCL22T90D1 or 2 8' 15 1/16° 0° 7 17/32' 717/32° SCL8T90 SCL8T90D1 or 2 24" 31 1/16" 0° 1517/32" 15 17/32" SCL24T90 SCL24T90D1 or 2 9° 16 1/16° 0" 81/32" 8 1/32" SCL9T90 SCL9T9001 or 2 26" 33 1/16" 0" 16 17/32" 16 17/32° SCL26T90 SCL26T90D1 or 2 10" 17 1/16" 0" 8 17/32" 817/32" SCL10T90 ' SCL10T90D1 or 2 28" 351/16" 0" 1717/32" 17 17/32" SCL28T90 SCL28T90D1 or 2 • 11" 18 1/16" 0" 91/32" 9 1/32" SCL11T90 SCL11T90D1 or 2 30" 371/16" 0" 1817/32" 18 17/32" SCL30T90 1 SCL30T90D1 or 2 12" 19 1/16" 0" 9 17/32' 917/32° SCL12T90 SC1_12T90D1 or 2 32" 39 1/16" 0' 1917/32" 1917/32" SCL32T90 SCL32T9001 or 2 13" 20 1/16° 0° 10 1/32° 10 1/32" SCL13T90 ISCL13T90D1 or 2 34" 41 1/16" 0° 2017/32" 20 17/32" SCL34T90 ] SCL34T90D1 or 2 14° 21 1/16° 0° 10 17/32" 10 17/32" SCL14T90 1 SCL14T90D1 or 2 36" 431/16" 0° 21 17/32" 21 17/32" SCL36T90 j SCL36T90D1 or 2 16" 23 1/16' 0° 11 17/32" 11 17/32" SCL16T90 'i SCL16T90D1 or 2 800-361-4909 (US) 1 800-667-3387 (Canada) 59 Grease Duct Accessories Round Flanged Hood Adaptor Used to connect the first duct section to hood. Can be field welded or supplied to Hood manufacturer for installation (by others). Included: For SCL: One (1) Locking Inner "V" Band (BSI). For CAX1, C/X1, CIX2, and CIX4: One (1) Locking Inner "V" Band (BSI), one (1) Locking Outer Band (BSE). Effective Length (in) SCL (Single Wall) 05" to 036" I 2 3/4" I SCLORFHA CAX1 (1" Air Insulated) CIX1 (1" Insulated) CIX2 (2" Insulated) CIX4 (4" Insulated) CAX1-0RFHA CIX1-9RFHA CIX2-0RFHA CIX4-0RFHA Materials available: 304, 316. Flow resistance: K = 0.825/0 2 3/4 i 0 Square to Round Adaptor Used to connect a round duct to a hood equipped with a square/rectangular collar or to connect to a square duct. STR's are a custom part and all requests need to go through the design group at layouts@securitychimneys.com Custom parts are non -returnable and may require extra production time. 11.:4111'.4 r tip SideView Option Square Flanga #1 0 800-361-4909(US) 800-667-3387 (Canada) 63 www.securitychimneys.com Security Chimneys International 2125 Monterey, Laval, Quebec Canada, H7L 3T6 450-973-9999 800-361-4909 (US) 800-667-3387 (Canada) 450-973-2222 (Fax) Need product information or technical support? Our customer service specialists are ready to answer your questions: 800-667-3387 or contact infoeng@securitychimneys.com *Linty Chimney PROCIX LS480_Catalog_Secure Stack Pro_10-16-18_V3 www.securitychimneys.com 800-361-4909 (US) 800-667-3387 (Canada) Security Chimneys International © 2016, 2017 Infnrmatinn niihlicharl in all R t-iirit, r'.himnovc litoratnro is riirront at timo of nnhliratinn and is cnhiort to rhanno IA,ithnnt nntiro I/ Morgan CAdvanced Materials FireMaster° FastWrap® '.6.v!Gvvmw r vm CODE COMPLIANCE • APPROVED AU6 O1 01 •+ • Zolq City of u la/ BUILDING DIVISION, M►7-0201 fiRE/0rfR Datasheet Code US: 714-236 © 2014 Thermal Ceramics is a business of Morgan Advanced Materials VALIDATED FIREMASTER ASTWRAPX 1 A LOS' ,O EEtA1TTIN MATEP.IAIPFR CA CTION 01350 FIREMA_ IER FASTWRAP 55 S'MOLD RESISTANT PER ASTM C1338738 LISTED • Commonly referred to test method CA Section 01350 is CDPH Standard Method for the Testing end Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers Version 1.1, Feb 2010 Grease Duct Enclosure System Air Ventilation Duct Enclosure System Product Data & Installation Guide 1. Product Description Thermal Ceramics FireMaster® FastWrap XL is a flexible blanket composed of high temperature fibers classified for applications to 2192°F (1200°C) and fully encapsulated in a durable glass fiber reinforced foil facing for easy handling and installation. Thermal Ceramics FastWrap XL is UL and ULC Listed for 1 and 2 hour fire resistive enclosure protection, zero clearance for kitchen exhaust ducts, electrical circuit protection, and as a component in UL firestop designs for fire resistance rated floors, ceilings, and walls. The core fibers in FastWrap XL are manufactured using Thermal Ceramics patented Superwool® fiber which is an alkaline -earth silicate wool with low biopersistence and therefore increased safety for installers. FastWrap XL is under UL's Follow -Up Service Program to ensure the consistent quality essential to this life -safety application. Product Features • Thin and Lightweight at 1-1/2" (38mm) thick, 6 pcf (96 kg/m3) density • Contours easily to complex duct designs • Grease duct installation UL and ULC Listed with butt joints at all seams on both layers • Fully foil encapsulated for fast and clean installation • Contains 2192°F (1200°C) rated fibers • Microbial Resistance validated by UL Environment • Good sound absorption • Compliant to IMC, NFPA 96, UMC, CMC, CNBC 2. Applications • 2 hour enclosure and firestop system for kitchen exhaus duct • Zero clearance to combustibles • 1, 2 and 3 hour enclosure and firestop system for hazardous exhaust ducts, pressurization ducts, clothes dryer exhaust ducts, trash and linen chutes, and other fire rated HVAC ducts • 1 hour electrical circuit integrity protection • Engineered and tested solutions for fire protection of structural steel and storage vessels per ASTM E119, ISO 834, and UL1709 3. Specifications - Division 23 07 00 (or 15080) CSI Spec and AutoCAD available online, www.arcat.com/sd/clients/thermcer.html. Thermal Ceramics FireMaster FastWrap XL is a flexible high temperature insulation rated to 2192°F (1200°C) that is fully encapsulated in FSP facing. The duct enclosure system shall be listed by UL and /or ULC per ASTM E 2336, CAN/ULC S144 and ISO 6944 for 1-, 2- and 3 -hour rating and zero clearance to combustibles, and tested per ASTM E84 for a flame/ smoke rating less than 25/50. Insulation shall have a nominal thickness of 1-1/2 inches (38 mm) and density of 6 lbs/ft3 (96 kg/m3). Insulation shall have a R -Value of 7.3 at 75°F. Installation shall be in strict accordance to manufacturers published installation instructions, UL or ULC Listings, and shop drawings. FastDoorTm XL shall be used for duct access where specified or as required by co N PAW-Is- � AUG 012QI9 www.morganthermalcera ics.com City of Tukwila QUILDING DIVISION 12:2014 Page 1 of 8 14 Morgan CAdvanced Materials FIREI��4TfR FireMaster° FastWrap® XL ia 4. Physical Characteristics Product Unit Size Units/ Ctn. Wt./ Ctn. FastWrap XL Roll 1-1/2" x 24" x 25 1 37.5 lbs. FastWrap XL Roll 1-1/2" x 48" x 25' 1 75 lbs. 5. Performance Specifications Reference Standard Standard No. Performance Grease Duct Enclosure System ASTM E2336 Pass Section 16.1 Non -Combustibility ASTM E136 Pass Section 16.2 -Fire Resistance (wall) ASTM E119 Pass Section 16.3 - Durability Test ASTM C518 Pass Section 16.4 - Internal Fire Test ASTM E2336 Pass Section 16.5 - Fire Engulfment (duct) ASTM E814/ E119 Pass ULC Grease Duct Test Protocol ULC Pass Standard Methods of Fire Resistance Tests - Grease Duct Assemblies CAN/ULC S144 Pass Grease Duct Clearances UL 1978 Pass Air Ventilation Duct Enclosure ISO 6944 Pass Surface Burning Characteristics ASTM E84 <25/50 Thermal Resistance (R -value @ 75°F) ASTM C518 7.3 per layer Mold Growth ASTM C1338 ULE Validated Low VOCs CA Standard 01350 ULE Validated 6. Listings/Building Code Reports Listed Uses Agency Listing Layers Grease Duct Enclosure per ASTM E2336 and AC101 (2006, 2009, 2012 IMC, NFPA 96, UMC, CMC) UL G18 2 ICC -ES ESR 2213 ULC Grease Duct Test Protocol and CAN/ULC S144" ULC FRD 4, 7" 2 Grease Duct Insulation (2003 IMC) OPL TC/BI 120-01 1 Through Penetration FireStop System per ASTM E814, UL 1479 UL See Figure 2 1 or 2 ULC 1- or 2 -hour Ventilation Duct Enclosure per ISO 6944-1985 UL HNLJ.V1, 19, 29 1 ULC FRD 3, 5, 6, 18 3 -hour Ventilation Duct Enclosure per ISO 6944-1985 UL HNLJ.V2 2 Electrical Circuit Protective System UL FHIT.5 2 7. Storage Thermal Ceramics FastWrap XL must be stored in a dry warehouse environment on pallets. Pallets should not be stacked. 8. Installation Thermal Ceramics FastWrap XL shall be installed by a qualified contractor in accordance with manufacturer's instructions and laboratory design listings. Materials and Equipment • Thermal Ceramics FastWrap XL blanket • Aluminum foil tape • Glass filament reinforced tape (optional) • Carbon steel or stainless steel banding material, minimum 1/2" (13mm) wide, minimum 0.015" (0.4mm) thick, with steel banding clips • Hand banding tensioner and crimping tool • Minimum 12 gage (3mm) steel insulation pins; steel speed clips, minimum 1-1/2" (38mm) square or 1-1/2" (38mm) diameter, or equivalent sized cup -head pins; • Capacitor discharge stud gun • Thermal Ceramics FastDoorTm XL • An approved firestop sealant www.morganthermalceramics.com 12:2014 Page 2 of 8 11 Morgan CAdvanced Materials f/RF((fgS7fR. FireMaster° FastWrap° XL Gi General Cut edges of the blanket shall be taped with aluminum foil tape to prevent exposed edges of the insulation absorbing grease and moisture in the event of a compromised grease duct joint or condensation. Overlaps and/or tightly butted joints are used to block heat transfer in the event of duct deformation resulting from thermal expansion. Filament tape is suggested to hold the blanket in place until steel banding or pinning is installed to permanently secure the blanket. A. Installation on Grease Duct per ASTM E2336 and CAN/ULC S144 (Figure 1) System requires two layers of insulation applied directly to the duct with tight butt joints at all seams on both layers. The first layer of insulation is cut to a length sufficient to wrap around the duct and provide a tight butt joint where the blanket ends meet. Adjacent blankets on the first layer are butted tightly together with longitudinal seams offset minimum 6" (150mm). The second layer of insulation is installed in the same method as the first layer, with seams between layers offset a minimum of 6" (150mm). Banding and/or pinning per Section D is used to permanently secure the insulation to the duct. B. Installation on HVAC Duct per ISO 6944 (Figure 1) System requires one layer of insulation applied directly to the duct with 3" (75mm) overlaps at all seams. The insulation is cut to a length sufficient to wrap around the duct and provide a 3" (75mm) overlap where the blanket ends meet. Adjacent blankets are installed to provide a minimum overlap of 3" (75mm). Banding and/or pinning per Section D is used to permanently secure the insulation to the duct. C. 2 & 3 Sided Wrap Installation (Figure 4) When space does not allow for a complete wrap applied to the duct on all four sides, the FastWrap XL is approved for 2 or 3 sided installations with mechanical attachment to a rated concrete or CMU assembly. (See Figure 4 for installation details.) D. Mechanical Attachment Methods 1) Banding (Figure 1) - Minimum 1/2" (13mm) wide carbon steel or stainless steel banding, 0.015" (0.4mm) thick, is placed around the entire perimeter of the insulated duct on maximum 10-1/2" (270mm) centers and 1-1/2" (38mm) from each blanket edge or 1-1/2" (38mm) from each collar edge when using the butt joint and collar method. The banding is placed around the blanket and tightened to firmly hold the FastWrap XL in place against the duct, but not cause any cutting or damage to the blanket. 2) Pinning - Pinning on all sides of the duct may be used as an alternative to banding. For ducts wider than 24" (610mm) pinning is required on the bottom of horizontal runs, or on one side of vertical runs (in addition to steel banding). When applicable, 12 Gage (0.4mm) steel pins are installed on 12" (305mm) centers along the width of the duct and 10-1/2" (270mm) centers along the length of the duct. Pins that extend beyond the outer blanket layer shall be turned down or the excessive length cut off to prevent sharp edges. Shoot through pins (cup head pins) may be used in conjunction with steel banding to prevent blanket sag. E. Access Doors 1) FastDoor XL (Figure 3) - FastDoor XL is a UL Listed, liquid tight duct cover panel supplied complete with a single layer insulation cover per UL Listing HNKT G18. The FastDoor XL is installed per included installation instructions. No field welding is required. 2) Field Fabricated Access Doors - Each access door assembly has four threaded rods 1/4 inch (6mm) in diameter and 5" (127mm) in length, with one welded to each corner of the door opening. Hollow steel tubes, 4-1/2" (114mm) long are installed outside the access cover plate and over the threaded rods. Four 12 gage (3mm) and 4-1/2" (114mm) long steel insulation pins are welded to the access cover plate to allow for installation of the three layers of FastWrap XL. One layer of FastWrap XL is cut to approximately the same size as the access panel, and impaled over the insulation pins on the panel. A second layer of FastWrap XL is cut so as to overlap the first layer a minimum of 1-1/2" (38mm). It is essential that the first and second layer fit tightly against the surrounding wrap with no through openings. The third and outside layer should be cut to overlap the second insulation layer by a minimum of 1-1/2" (38mm). Minimum 1-1/2" (38mm) round or square insulation clips are installed on the insulation pins to secure the three layers of insulation to the access cover plate. All cut edges of the insulation shall be taped with minimum 3" (75mm) wide aluminum foil tape. Wing nuts and washers are installed on the four threaded rods, and tightened against the hollow steel tubes to seal the www.morganthermalceramics.com 12:2014 Page 3of8 11 Morgan CAdvanced Materials f/RfelSTER FireMaster° FastWrap® XL access cover plate to the duct. F. Through Penetration Firestop System (Figure 2) - When the duct penetrates a fire rated assembly an approved fire stop system must be employed. Figure 2 provides a complete list of UL / ULC firestop design listings which can be found in the Certifications Directory at www.ul.com for US systems and www.ulc.ca for Canadian systems. Prior to installing any firestop system the surfaces of all openings and penetrating items must be clean and dry. The FastWrap XL core blanket (or mineral wool where allowed by the firestop design listing) must be compressed into the annular space. The packing material must be recessed a minimum depth from the surface of the concrete or gypsum assembly. The recessed opening must be filled with a minimum thickness of an approved firestop sealant. The packing material type and compression, minimum recess (typically 1/4" (6mm)), and approved firestop sealant and thickness (typically 1/4" (6mm)) shall be as specified in an approved UL / ULC firestop design listing. When there is not sufficient annular space around the duct to run the FastWrap XL enclosure system continuous through the fire rated assembly, the enclosure may terminate above and below the floor/ceiling assembly or on either side of a wall assembly as shown in Figure 2. When this method is used, the FastWrap XL must be mechanically attached on either side of the fire rated assembly using one of the attachment methods described in Section D, spaced a maximum of 1-1/2" (38mm) from the fire rated assembly. G. Support Hanger Systems 1) Grease ducts: Trapeze support hangers shall be spaced on maximum 60 in. (1500 mm) centers. Hanger rods or straps shall be anchored with steel drop in or wedge expansion type masonry anchors. No additional protection is required for hangers and supports meeting the requirements of the Table below. Hanger Cross Section Maximum Perimeter, in (mm) Trapeze Support (or equivalent Yield Strength), in (mml 313 in (10 mm) threaded rod 148 (3759) 2 (51) x 2 (51) x 18 (3) in angle 2) HVAC ducts: Trapeze support hangers shall be spaced on maximum 60 in. (1500 mm) centers. Hanger rods or straps shall be anchored with steel drop in or wedge expansion type masonry anchors. No additional protection is required for hangers and supports meeting the requirements of the Table below. Hanger Cross Section Max. Perimeter, in (mm) Trapeze Support (or equivalent Yield Strength), in (mm) 1 in x 16 gage strap (25 mm x 1.5 gage strap) 100 (2540) 14 in (6 mm) threaded rod 50 (1270) 1h (38) x 1X (38) x 316 (5) angle 313 in (10 mm) threaded rod 150 (3810) 1h (38) x 1h (38) x 316 (5) angle 12 in (12.7 mm) threaded rod 218 (5540) 2 (51) x 2 (51) x 14 (6) angle 9. Maintenance and Repair No maintenance is required when installed in accordance with Thermal Ceramics (TC) installation instructions. If damage is limited to the foil facing, aluminum foil tape can be used to repair the foil facing. If an area of blanket is found to be damaged the following procedure must be in- corporated. If the damaged area is larger than 8" (203mm) x 8" (203mm) the entire wrap section must be removed and replaced according to TC installation instructions. If the damaged area is small (less than 8" (203mm) x 8" (203mm)), the damaged area must be cut away and replaced with a new section 1" (25mm) larger in length and width than the cut out, such that the new section can be compressed tightly into the cut out area. All cut edges of the new section must be taped and sealed with aluminum foil tape. The new section must be held in place with either pinning or banding per TC installation i nstructions. 10. Limitations Thermal Ceramics FireMaster FastWrap XL shall be installed in accordance with these installation instructions and appropriate laboratory design listings. The integrity of FastWrap XL systems is limited to the quality of the installation. For personal protective equipment recommendations, please see SDS. Thermal Ceramics, FireMaster, and FastWrap are trademarks of Morgan Advanced Materials. FireMaster products are manufactured by Thermal Ceramics and are distributed by authorized distributors. www.morganthermalceramics.com 12:2014 Page 4 of 8 14 Morgan Advanced Materials FireMaster° FastWrap® XL 11) Grease and HVAC Duct Enclosure System 1 or 2 Hour Shaft Alternative / Zero Clearance to Combustibles 1 1? (38)I I xvXxv�vtWIvcti1/4"1/ f�Y :r/xnrnrnrnri �vxnrnrnvxnixiri. Butt Joint / Butt Joint Typical TWO LAYER INSTALLATION (Grease Duct perASTM E2336 and CAN/ULC 5144) Telescope Wrap Option Butt Joint Option Checkerboard Wrap Option SINGLE LAYER INSTALLATION OPTIONS (2 -Hour rated HVAC Duct oer UL HNLJ V-19) LEGEND 1 Two Layers of XL Insulation for ASTM E2336 and CAN/ULC S144 Grease Duct Endosures One Layer of XL Insulation for 2 -Hour Air Ventilation Duct Endosures 2 Steel banding minimum 1/2" (13) wide by 0.015" (0.4) thick. 3 light butt joints (no overlap) at perimeter and longitudinal joints, both layers for grease ducts 4 Min. 3" (75) overlap on perimeter and between adjacent blankets 5 Optional 6" XL collar 6 Hangers - size dependent weight of assembly (see datasheet Section G) 7 Trapeze Supports - size dependent on weight of assembly (see datasheet Section G) 8 Steel Rectangular or Round Duct (size, gage and construction dependent per Listed Design) The Integrity of Thermal Ceramics duct systems is Gated to the quality of the Installation. XL001-10 www.morganthermalceramics.com 12:2014 Page 5 of 8 14 Morgan CAdvanced Materials f/Rf64STfR FireMaster° FastWrap® XL Commercial Kitchen Grease Duct Enclosure System Air Ventilation Duct Enclosure System Through Penetration Firestop Systems 00 © 11.1; 11111 111111 Packing XL Insulation continuous through rated wall assembly XL insulation terminated on both sides of the rated wall assembly XL Insulation continuous through rated floor/ceiling assembly XL insulation terminated at the top and bottom surface of the floor/ceiling assembly Firestop Designs per ASTM E814 / UL 1479 - Consult UL / ULC Directories for System Details UL Listing F- 8, T -Rating (1) Floor/Wall (2) Penetrant (3) Enclosure Per (4) Termination (5) Firestop Sealant Details C -AJ -7012 2 -hour Concrete/CMU 84x24; 26 Ga Duct V19; FRD3; 5; 18 wrap through 1/2 in; STI; Tremco C -AJ -7014 3 -hour Concrete/CMU 84x24; 26 Ga Duct V2; wrap through 1/2 in; STI; Tremco C -AJ -7019 1 or 2 -hour Concrete/CMU 84x24; 26 Ga Duct V19; FRD3, 5, 18 terminate at 1/4 in; STI; Tremco C -AJ -7021 2 -hour Concrete/CMU 49x24; 16 Ga Duct G18; FRD4; 7 terminate at 1/4 in; STI; Tremco C -AJ -7095 2 -hour Concrete/CMU 39x39: 22 Ga Duct V19; FRD3, 5, 18 wrap through 1/4 in; STI Hilti; Rectorseal; Tremco C -AJ -7098 2 -hour Concrete/CMU 49x24; 16 Ga Duct G18; FRD4; 7 _ wrap through 1/4 in; STI; Hilti; Rectorseal; Tremco F-0.7036 1 or 2 -hour Wood/Gyp Floor 24x12; 16 Ga Duct G18; FRD4; 7 wrap through 1/4 in; STI; Hilti; Rectorseal; Tremco F-0-7055 1 -hour Wood/Gyp Floor 4 Dia; 30 Ga Duct V29; FRD28 v wrap through 1/4 in; STI W -J-7086 2 -hour Concrete/CMU Wall 100x100; 26 Ga Duct V19; FRD3;5; 18 _ terminate at 1/4 in; STI W -L-7121 1 or 2 -hour Gyp Wall 30x30; 16 Ga Duct G18; FRD4; 7 _ wrap through 1/4 in; STI; Hilti; Rectorseal; Tremco W -L-7145 1 or 2 -hour Gyp Wall 100x100; 26 Ga Duct V19; FRD3; 5; 18 _ terminate at 5/8 in; STI The Integrity of Thermal Ceramics duct systems le Ilmtted to the Quality of the Installation. XLoo36 www.morganthermalceramics.com 12:2014 Page 6 of 8 IA Morgan CAdvanced Materials f/Rf��S7ER FireMaster® FastWrap® XL ASTM E 2336 Compliant Enclosure and Door System FIGURE 3 1 UL listed FastDoor XL access panel 2 All Thread Rods and wing nuts 3 Retainer Clips with threaded nut and wing bolts 4 Insulation layers as required by UL or ITS Listings 5 FastDoor XL; 1-1/2 inch thick single layer insulation FastDoor XL1 Access Doors Sizes Available Opening Sizes Ordering Code 10" x 4" Door Opening *434-0970-033-99X1 10" x 6" Door Opening 434-6970-034-99X1 12" x 8" Door Opening 434-6970-035-99X1 12" x 12" Door Opening 434-6970-036-99X1 16" x 12" Door Opening 434-6970-037-99X1 20" x 20" Door Opening 434-6970-038-99X1 *Special Order, Curved and SS Available www.morganthermalceramics.com 12:2014 Page 7 of 8 14 Morgan CAdvanced Materials f/RfeyTfR FireMaster® FastWrap® XL (1) Commercial Kitchen Grease Duct Enclosure System Air Ventilation Duct Enclosure System 1 Or 2 Or 3 Hour Shaft Alternative / Zero Clearance to Combustibles 2 and 3 Sided Wrap Detail for Attaching to Walls and/or Ceilings '�— XL005-4 Note: Ducts must be independently supported per code LEGEND 1 Rated Concrete floor/ceiling, or wall - with rating equal or greater than enclosure rating 2 Two layers of XL Insulation for Grease Duct Enclosures (install per UL G18)) One layer of XL Insulation for Air Ventilation Duct Enclosures (install per UL V19) Two layers of XL Insulation for 3 -hr Air Ventilation Duct Enclosure (install per UL V2) 3 Concrete fastener system 4 3/16" (5) thick x 2" (50) -3" (75) wide bar stock perforated 12" (305) o.c. 5 8" (203) maximum Air Gap 6 Duct 7 Steel banding min. 1/2" (13) wide by 0.015" (0.4) thick. 8 Banding clip The integrity of Morgan Thermal Ceramics duct systems is limited to the quality of the installation. www.morganthermalceramics.com 12:2014 Page 8 of 8 FILE Heating and Cooling Calculations REVIEWED FOR CODE COMPLIANCE APPROVED MAY 23 2018 City of Tukwila BUILDING DIVISION December 19, 2017 Issued for Mechanical Permit Sterling Southcenter 415 Baker Boulevard Tukwila, WA 98188 C 7M] OCEAN PARK MECHANICAL #283 - 14900 Inter Urban Avenue Seattle, WA 98168 Ph: (206) 674-4553 Fax: (206) 674-4564 ML7O1O1 RECEIVED CITY OF TUKWILA DEC 21. 2011 PERMIT CENTER C Air System Design Load Summary for 01 B.1 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 1 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DB / WB 81.0°F/66.0°F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0°F/19.2°F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hrL Latent (BTU/hr) Window & Skylight Solar Loads 102 ft2 1054 - 102 ft2 - - Wall Transmission 128 ft2 96 - 128 ft2 317 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 102 ft2 92 - 102 ft2 1548 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 577 ft2 39 - 577 ft2 664 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 577 W 1969 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 182 51 - 1398 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 3923 461 - 3927 0 Zone Conditioning - 3661 461 - 3766 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Pienum Lighting Load 0% 0 - 0 0 - Return Fan Load 185 CFM 0 - 185 CFM 0 - Ventilation Load 60 CFM 304 108 60 CFM 2857 0 Supply Fan Load 185 CFM 0 - 185 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 3966 569 - 6623 0 Central Cooling Coil - 3966 569 - 0 0 Central Heating Coil - 0 - - 6623 - » Total Conditioning - 3966 569 - 6623 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg Toads Hourly Analysis Program v4.60 Page 1 of 31 Air System Design Load Summary for 02 C.1 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 2 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 79.2 °F / 65.4 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F 119.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 258 ft2 5861 - 258 ft2 - - Wall Transmission 329 ft2 585 - 329 ft2 815 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 258 ft2 160 - 258 ft2 3916 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 872 ft2 41 - 872 ft2 1003 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 872 W 2975 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 735 615 0 0 0 Infiltration - 192 140 - 2113 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 10549 755 - 7847 0 Zone Conditioning - 9989 755 - 7764 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 496 CFM 0 - 496 CFM 0 - Ventilation Load 60 CFM 191 195 60 CFM 2881 0 Supply Fan Load 496 CFM 0 - 496 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 10179 950 - 10646 0 Central Cooling Coil - 10179 950 - 0 0 Central Heating Coil - 0 - - 10646 - » Total Conditioning - 10179 950 - 10646 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 2 of 31 Air System Design Load Summary for 03 A.1 S Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 3 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1400 COOLING OA DB / WB 81.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 53 ft2 1706 53 ft2 - - Wall Transmission 59 ft2 160 - 59 ft2 146 - Roof Transmission 356 ft2 969 - 356 ft2 785 - Window Transmission 53 ft2 55 - 53 ft2 805 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 356 W 1215 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 114 12 - 812 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 4708 422 - 2548 0 Zone Conditioning - 4447 422 - 2497 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 229 CFM 0 - 229 CFM 0 - Ventilation Load 60 CFM 332 42 60 CFM 2896 0 Supply Fan Load 229 CFM 0 - 229 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 4779 464 - 5393 0 Central Cooling Coil - 4779 465 - 0 0 Central Heating Coil - 0 - - 5393 - » Total Conditioning - 4779 465 - 5393 0 Key: Positive values are clg loads Negative values are htg Toads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 31 Air System Design Load Summary for 04 A.2 N Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 4 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1400 COOLING OA DB / WB 80.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 53 ft2 549 - 53 ft2 - - Wall Transmission 75 ft2 54 - 75 ft2 186 Roof Transmission 393 ft2 1226 - 393 ft2 867 - Window Transmission 53 ft2 37 - 53 ft2 805 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 393 W 1341 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 106 44 - 896 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 3803 454 - 2754 0 Zone Conditioning - 3615 454 - 2723 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 179 CFM 0 - 179 CFM 0 - Ventilation Load 60 CFM 274 145 60 CFM 2880 0 Supply Fan Load 179 CFM 0 - 179 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 3888 600 - 5603 0 Central Cooling Coil - 3888 600 - 0 0 Central Heating Coil - 0 - - 5603 - » Total Conditioning - 3888 600 - 5603 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 4 of 31 Air System Design Load Summary for 05 A.2 S Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 5 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Sep 1400 COOLING OA DB / WB 79.5 °F / 64.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 53 ft2 2144 - 53 ft2 - - Wall Transmission 75 ft2 230 - 75 ft2 186 - Roof Transmission 403 ft2 810 - 403 ft2 889 - Window Transmission 53 ft2 20 - 53 ft2 805 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - • 0 ft2 0 - Overhead Lighting 403 W 1375 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 89 19 - 919 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 5158 429 - 2799 0 Zone Conditioning - 4926 429 - 2741 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 244 CFM 0 - 244 CFM 0 - Ventilation Load 60 CFM 210 59 60 CFM 2893 0 Supply Fan Load 244 CFM 0 - 244 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 5136 488 - 5635 0 Central Cooling Coil - 5136 488 - 0 0 Central Heating Coil - 0 - - 5635 - » Total Conditioning - 5136 488 - 5635 0 Key: Positive values are clg loads Negative values are htg Toads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 5 of 31 Air System Design Load Summary for 06 A.2 W Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 6 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1600 COOLING OA DB / WB 80.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 53 ft2 1938 - 53 ft2 - - Wall Transmission 75 ft' 239 - 75 ft2 186 - Roof Transmission 403 ft2 1023 - 403 ft2 889 - Window Transmission 53 ft2 45 - 53 ft2 805 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 403 W 1375 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 109 48 - 919 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 5219 458 - 2799 0 Zone Conditioning - 4908 458 - 2666 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 246 CFM 0 - 246 CFM 0 - Ventilation Load 60 CFM 265 152 60 CFM 2887 0 Supply Fan Load 246 CFM 0 - 246 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 5172 609 - 5554 0 Central Cooling Coil - 5172 610 - 0 0 Central Heating Coil - 0 - - 5554 - » Total Conditioning - 5172 610 - 5554 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 6 of 31 Air System Design Load Summary for 07 A.3 W Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 7 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DB 1 WB 81.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F 119.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 35 ft2 1125 - 35 ft2 - - Wall Transmission 49 ft2 134 - 49 ft2 121 - Roof Transmission 565 ft2 1643 - 565 ft2 1246 - Window Transmission 35 ft2 31 - 35 ft2 531 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 565 W 1928 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 168 71 - 1289 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 >> Total Zone Loads 5519 481 - 3188 0 Zone Conditioning - 5193 481 - 3233 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 260 CFM 0 - 260 CFM 0 - Ventilation Load 60 CFM 304 160 60 CFM 2898 0 Supply Fan Load 260 CFM 0 - 260 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 5496 641 - 6131 0 Central Cooling Coil - 5496 641 - 0 0 Central Heating Coil - 0 - - 6131 - » Total Conditioning - 5496 641 - 6131 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 7 of 31 Air System Design Load Summary for 08 A.4 W Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 8 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DB / WB 81.0°F/66.0°F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0°F/19.2°F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 35 ft' 1125 - 35 ft' - - Wall Transmission 49 ft' 134 - 49 ft' 121 - Roof Transmission 539 ft2 1568 - 539 ft2 1189 - Window Transmission 35 ft' 31 - 35 ft2 531 - Skylight Transmission 0 ft' 0 - 0 ft2 0 - Door Loads 0 ft' 0 - 0 ft' 0 - Floor Transmission 0 ft2 0 - 0 ft' 0 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 539 W 1839 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 160 66 - 1229 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 5347 476 - 3071 0 Zone Conditioning - 5024 476 - 3104 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 252 CFM 0 - 252 CFM 0 - Ventilation Load 60 CFM 304 157 60 CFM 2897 0 Supply Fan Load 252 CFM 0 - 252 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 5329 632 - 6000 0 Central Cooling Coil - 5329 633 - 0 0 Central Heating Coil - 0 - - 6000 - » Total Conditioning - 5329 633 6000 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 8 of 31 Air System Design Load Summary for 09 A.5 W Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 9 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DB / WB 81.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 35 ft2 1125 - 35 ft2 - - Wall Transmission 49 ft' 134 - 49 ft2 121 - Roof Transmission 547 ft2 1591 - 547 ft2 1207 - Window Transmission 35 ft2 31 - 35 ft2 531 - Skylight Transmission 0 ft' 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 547 W 1866 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 163 66 - 1248 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 >> Total Zone Loads - 5400 476 - 3107 0 Zone Conditioning - 5071 476 - 3240 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 254 CFM 0 - 254 CFM 0 - Ventilation Load 60 CFM 304 156 60 CFM 2902 0 Supply Fan Load 254 CFM 0 - 254 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 5375 633 - 6142 0 Central Cooling Coil - 5375 633 - 0 0 Central Heating Coil - 0 - - 6142 - » Total Conditioning - 5375 633 - 6142 0 Key: Positive values are clg loads Negative values are htg Toads Positive values are htg loads Negative values are clg Toads Hourly Analysis Program v4.60 Page 9 of 31 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical Air System Design Load Summary for 10 B.2 E 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 10 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1300 COOLING OA DB / WB 79.0 °F / 65.4 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 95 ft2 2472 - 95 ft2 - - Wall Transmission 97 ft2 111 - 97 ft2 240 - Roof Transmission 554 ft2 1752 - 554 ft2 1222 - Window Transmission 95 ft2 29 - 95 ft2 1442 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 554 W 1890 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 110 95 - 1264 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 6853 505 - 4168 0 Zone Conditioning - 6589 505 - 4040 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 322 CFM 0 - 322 CFM 0 - Ventilation Load 60 CFM 178 221 60 CFM 2883 0 Supply Fan Load 322 CFM 0 322 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 6767 727 - 6923 0 Central Cooling Coil - 6767 727 - 0 0 Central Heating Coil - 0 - - 6923 - » Total Conditioning - 6767 727 - 6923 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 10 of 31 Air System Design Load Summary for 11 B.2 N Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 11 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DB / WB 81.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 95 ft2 982 - 95 ft2 - - Wall Transmission 89 ft2 83 - 89 ft2 220 - Roof Transmission 554 ft2 1611 - 554 ft2 1222 - Window Transmission 95 ft2 85 - 95 ft2 1442 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 554 W 1890 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 165 58 - 1264 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 5307 468 - 4148 0 Zone Conditioning - 4988 468 - 4045 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Pienum Lighting Load 0% 0 - 0 0 - Return Fan Load 253 CFM 0 - 253 CFM 0 - Ventilation Load 60 CFM 307 135 60 CFM 2874 0 Supply Fan Load 253 CFM 0 - 253 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 5295 604 - 6919 0 Central Cooling Coil - 5295 604 - 0 0 Central Heating Coil - 0 - - 6919 - » Total Conditioning - 5295 604 - 6919 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 11 of 31 Air System Design Load Summary for 12 B.2 S Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 12 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1500 COOLING OA DB / WB 82.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 95 ft2 2836 - 95 ft2 - - Wall Transmission 89 ft2 217 - 89 ft2 220 - Roof Transmission 554 ft2 1377 - 554 ft2 1222 - Window Transmission 95 ft2 117 - 95 ft2 1442 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 554 W 1890 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 192 28 - 1264 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 7119 438 - 4148 0 Zone Conditioning - 6978 438 - 4013 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 367 CFM 0 - 367 CFM 0 - Ventilation Load 60 CFM 382 65 60 CFM 2896 0 Supply Fan Load 367 CFM 0 - 367 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 7359 503 - 6909 0 Central Cooling Coil - 7359 504 - 0 0 Central Heating Coil - 0 - - 6909 - » Total Conditioning - 7359 504 - 6909 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 12 of 31 Air System Design Load Summary for 13 B.3 S Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 13 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1400 COOLING OA DB / WB 81.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 51 ft2 1641 - 51 ft2 - - Wall Transmission 85 ft2 231 - 85 ft2 210 - Roof Transmission 574 ft2 1562 - 574 ft2 1266 - Window Transmission 51 ft2 53 - 51 ft2 774 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 574 W 1958 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 184 33 - 1309 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 6119 443 - 3560 0 Zone Conditioning - 5647 443 - 3585 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 288 CFM 0 - 288 CFM 0 - Ventilation Load 60 CFM 328 73 60 CFM 2896 0 Supply Fan Load 288 CFM 0 - 288 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 5975 516 - 6481 0 Central Cooling Coil - 5975 516 - 0 0 Central Heating Coil - 0 - - 6481 - » Total Conditioning - 5975 516 - 6481 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 13 of 31 Air System Design Load Summary for 14 B.4 N Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 14 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1400 COOLING OA DB / WB 80.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 51 ft2 528 - 51 ft2 - - Wall Transmission 85 ft2 61 - 85 ft2 210 - Roof Transmission 511 ft2 1594 - 511 ft2 1127 - Window Transmission 51 ft2 36 - 51 ft2 774 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 511 W 1743 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 2 490 410 0 0 0 Infiltration - 138 41 - 1166 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 4591 451 - 3278 0 Zone Conditioning - 4232 451 - 3253 0 Plenum•Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 216 CFM 0 - 216 CFM 0 - Ventilation Load 60 CFM 267 102 60 CFM 2881 0 Supply Fan Load 216 CFM 0 - 216 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads 4499 553 - 6133 0 Central Cooling Coil - 4499 553 - 0 0 Central Heating Coil - 0 - - 6133 - » Total Conditioning - 4499 553 - 6133 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 14 of 31 Air System Design Load Summary for 15 C.2 NW Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 15 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1600 COOLING OA DB / WB 80.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 221 ft2 5287 - 221 ft2 - - Wall Transmission 392 ft2 750 - 392 ft2 971 - Roof Transmission 867 ft2 2201 - 867 ft2 1913 - Window Transmission 221 ft2 187 - 221 ft2 3355 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 867 W 2958 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 735 615 0 0 0 Infiltration - 234 165 - 1978 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 12353 780 - 8216 0 Zone Conditioning - 11898 780 - 8082 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 581 CFM 0 - 581 CFM 0 - Ventilation Load 60 CFM 274 244 60 CFM 2885 0 Supply Fan Load 581 CFM 0 - 581 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 12171 1024 - 10968 0 Central Cooling Coil - 12171 1025 - 0 0 Central Heating Coil - 0 - - 10968 - » Total Conditioning - 12171 1025 - 10968 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 15 of 31 Air System Design Load Summary for 16 C.2 SW Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 16 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1500 COOLING OA DB / WB 82.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS . Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 221 ft2 6466 - 221 ft2 - - Wall Transmission 392 ft2 975 - 392 ft2 971 - Roof Transmission 867 ft2 2155 - 867 ft2 1913 - Window Transmission 221 ft2 271 - 221 ft2 3355 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 867 W 2958 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 735 615 0 0 0 Infiltration - 301 91 - 1978 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 13861 706 - 8216 0 Zone Conditioning - 13014 706 - 8168 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 652 CFM 0 - 652 CFM 0 - Ventilation Load 60 CFM 364 135 60 CFM 2893 0 Supply Fan Load 652 CFM 0 - 652 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 13378 841 - 11061 0 Central Cooling Coil - 13378 842 - 0 0 Central Heating Coil - 0 - - 11061 - » Total Conditioning - 13378 842 - 11061 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 16 of 31 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical Air System Design Load Summary for 17 C.3 SE 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 17 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1400 COOLING OA DB / WB 81.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 202 ft2 5446 - 202 ft2 - - Wall Transmission 418 ft2 850 - 418 ft2 1035 - Roof Transmission 910 ft2 2476 - 910 ft2 2008 - Window Transmission 202 ft2 209 - 202 ft2 3066 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 910 W 3105 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 735 615 0 0 0 Infiltration - 291 130 - 2076 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 13112 745 - 8185 0 Zone Conditioning - 12593 745 - 7960 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 617 CFM 0 - 617 CFM 0 - Ventilation Load 60 CFM 337 184 60 CFM 2890 0 Supply Fan Load 617 CFM 0 - 617 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 12930 930 - 10849 0 Central Cooling Coil - 12930 930 - 0 0 Central Heating Coil - 0 - - 10849 - » Total Conditioning - 12930 930 - 10849 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 17 of 31 Air System Design Load Summary for 18 C.4 NE Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 18 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1400 COOLING OA DB / WB 80.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F 119.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTUIhr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 244 ft2 4215 - 244 ft2 - - Wall Transmission 330 ft2 290 - 330 ft2 817 - Roof Transmission 976 ft2 3045 - 976 ft2 2153 - Window Transmission 244 ft2 171 - 244 ft2 3704 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 976 W 3330 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 735 615 0 0 0 Infiltration - 264 188 - 2226 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 12050 803 - 8901 0 Zone Conditioning - 11643 803 - 9016 0 Plenum Wall Load 0% , 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Pienum Lighting Load 0% 0 - 0 0 - Return Fan Load 567 CFM 0 - 567 CFM 0 - Ventilation Load 60 CFM 275 248 60 CFM 2889 0 Supply Fan Load 567 CFM 0 - 567 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 11918 1051 - 11905 0 Central Cooling Coil - 11918 1052 - 0 0 Central Heating Coil - 0 - - 11905 - » Total Conditioning - 11918 1052 - 11905 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 18 of 31 Air System Design Load Summary for 19 C.5 E Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 19 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1300 COOLING OA DB 1 WB 80.0°F/65.4°F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F119.2°F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 130 ft2 3297 - 130 ft2 - - Wall Transmission 201 ft2 209 - 201 ft2 498 - Roof Transmission 821 ft2 2541 - 821 ft2 1811 - Window Transmission 130 ft2 83 - 130 ft2 1973 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 821 W 2801 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 735 615 0 0 0 Infiltration - 203 91 - 1873 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 9869 706 - 6155 0 Zone Conditioning - 9441 706 - 6175 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 467 CFM 0 - 467 CFM 0 - Ventilation Load 60 CFM 242 142 60 CFM 2895 0 Supply Fan Load 467 CFM 0 - 467 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 9682 848 - 9070 0 Central Cooling Coil - 9682 848 - 0 0 Central Heating Coil - 0 - - 9070 - » Total Conditioning - 9682 848 - 9070 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 19 of 31 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical Air System Design Load Summary for 20 C.6 E 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 20 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1300 COOLING OA DB / WB 79.0 °F / 65.4 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F 119.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 130 ft2 3383 - 130 ft2 - - Wall Transmission 175 ft2 196 - 175 ft2 433 - Roof Transmission 772 ft2 2441 - 772 ft2 1703 - Window Transmission 130 ft2 40 - 130 ft2 1973 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 772 W 2634 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 3 735 615 0 0 0 Infiltration - 153 121 - 1761 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 9581 736 - 5871 0 Zone Conditioning - 9163 736 - 5894 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 451 CFM 0 - 451 CFM 0 - Ventilation Load 60 CFM 175 201 60 CFM 2896 0 Supply Fan Load 451 CFM 0 - 451 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 9338 937 - 8791 0 Central Cooling Coil - 9338 937 - 0 0 Central Heating Coil - 0 - - 8791 - » Total Conditioning - 9338 937 - 8791 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 20 of 31 Air System Design Load Summary for 21 Bistro/Lobby Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 21 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1400 COOLING OA DB / WB 81.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 1063 ft2 16523 - 1063 ft2 - - Wall Transmission 670 ft2 609 - 670 ft2 1659 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 1063 ft2 1098 - 1063 ft2 16136 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 3423 W 11679 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 56 13720 11480 0 0 0 Infiltration - 1807 -205 - 12883 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 >> Total Zone Loads - 45435 11275 - 30678 0 Zone Conditioning - 44225 11275 - 30807 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 2144 CFM 0 - 2144 CFM 0 - Ventilation Load 950 CFM 5272 -742 950 CFM 45767 0 Supply Fan Load 2144 CFM 0 - 2144 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 49496 10533 - 76574 0 Central Cooling Coil - 49496 10538 - 0 0 Central Heating Coil - 0 - - 76574 - » Total Conditioning - 49496 10538 - 76574 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 21 of 31 Air System Design Load Summary for 21 Bistro/Lobby/Game/Reading Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 22 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1400 COOLING OA DB / WB 80.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 1270 ft2 21014 - 1270 ft2 - - Wall Transmission 770 ft2 678 - 770 ft2 1907 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 1270 ft2 893 - 1270 ft2 19279 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 459 ft2 59 - 459 ft2 1267 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 4779 W 16306 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 72 18200 15800 0 0 0 Infiltration - 1912 74 - 16131 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 59061 15874 - 38583 0 Zone Conditioning - 58122 15874 - 37562 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 2780 CFM 0 - 2780 CFM 0 - Ventilation Load 1200 CFM 5472 267 1200 CFM 57703 0 Supply Fan Load 2780 CFM 0 - 2780 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads 63594 16141 - 95265 0 Central Cooling Coil - 63594 16141 - 0 0 Central Heating Coil - 0 - - 95265 - » Total Conditioning - 63594 16141 - 95265 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 22 of 31 Air System Design Load Summary for 22 Great Room 104 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 23 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 82.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 267 ft2 6245 - 267 ft2 - - Wall Transmission 242 ft2 242 - 242 ft2 599 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 267 ft2 328 - 267 ft2 4053 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 279 ft2 62 - 279 ft2 770 - Ceiling 1520 ft2 141 - 1520 ft2 1748 - Overhead Lighting 1520 W 5186 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 760 W 2593 - 0 0 - People 34 7820 4080 0 0 0 Infiltration - 594 73 - 3901 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 23212 4153 - 11071 0 Zone Conditioning - 23084 4153 - 10852 0 Plenum Wall Load 0% 0 - 0 0 - Pienum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 1128 CFM 0 - 1128 CFM 0 - Ventilation Load 700 CFM 4332 636 700 CFM 33801 0 Supply Fan Load 1128 CFM 0 - 1128 CFM 0 - Space Fan Coil Fans - 0 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 27416 4789 - 44653 0 Central Cooling Coil - 27416 4789 - 0 0 Central Heating Coil - 0 - - 44653 - » Total Conditioning - 27416 4789 - 44653 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg Toads Hourly Analysis Program v4.60 Page 23 of 31 Air System Design Load Summary for 23 Staff Room 109 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 24 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 82.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 117 ft2 26 - 117 ft2 323 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 131 W 447 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 4 980 820 0 0 0 Infiltration - 51 -39 - 336 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 1504 781 - 659 0 Zone Conditioning - 1492 781 - 683 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 71 CFM 0 - 71 CFM 0 - Ventilation Load 50 CFM 306 -287 50 CFM 2424 0 Supply Fan Load 71 CFM 0 - 71 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 1799 494 - 3107 0 Central Cooling Coil - 1799 494 - 0 0 Central Heating Coil - 0 - - 3107 - » Total Conditioning - 1799 494 - 3107 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg Toads Negative values are clg loads Hourly Analysis Program v4.60 Page 24 of 31 Air System Design Load Summary for 24 Manager/Conference/Lobby Project Name: Broadstone Sterling South Center 12/19/2017 Prepared by: Ocean Park Mechanical 02:09PM Hourly Analysis Program v4.60 Page 25 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DB / WB 81.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 325 ft2 3360 - 325 ft2 - - Wall Transmission 171 ft2 133 - 171 ft2 423 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 325 ft2 292 - 325 ft2 4934 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 207 ft2 34 - 207 ft2 571 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1103 W 3763 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 16 3680 1920 0 0 0 Infiltration - 369 77 - 2830 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 >> Total Zone Loads - 11631 1997 - 8759 0 Zone Conditioning - 11203 1997 - 8418 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 554 CFM 0 - 554 CFM 0 - Ventilation Load 250 CFM 1272 330 250 CFM 11983 0 Supply Fan Load 554 CFM 0 - 554 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 12475 2327 - 20401 0 Central Cooling Coil - 12475 2328 - 0 0 Central Heating Coil - 0 - - 20401 - » Total Conditioning - 12475 2328 - 20401 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 25 of 31 Air System Design Load Summary for 27 Reading/Game Room Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 26 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1500 COOLING OA DBIWB 81.0°F/66.0°F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0°F/19.2°F ZONE LOADS Details Sensible (BTU/hr) Latent (BTUIhr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 207 ft' 3601 - 207 ft' - - Wall Transmission 100 ft' 91 - 100 ft2 248 - Roof Transmission 0 ft' 0 - 0 ft' 0 - Window Transmission 207 ft' 186 - 207 ft2 3142 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 0 ft' 0 - 0 ft' 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 459 ft2 75 - 459 ft' 1267 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 1356 W 4627 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 16 4480 4320 0 0 0 Infiltration - 424 -108 - 3248 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 13483 4212 - 7904 0 Zone Conditioning - 13047 4212 - 7523 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 636 CFM 0 - 636 CFM 0 - Ventilation Load 250 CFM 1244 -406 250 CFM 12023 0 Supply Fan Load 636 CFM 0 - 636 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 14291 3806 - 19546 0 Central Cooling Coil - 14291 3807 - 0 0 Central Heating Coil - 0 - - 19546 - » Total Conditioning - 14291 3807 - 19546 0 Key: Positive values are clg loads Negative values are htg Toads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 26 of 31 Air System Design Load Summary for 28 Theatre 204 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 27 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1400 COOLING OA DB / WB 80.5 °F / 65.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 254 ft2 2630 - 254 ft2 - - Wail Transmission 82 ft2 65 - 82 ft2 203 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 254 ft2 179 - 254 ft2 3856 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 728 W 2484 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 15 3450 1800 0 0 0 Infiltration - 207 26 - 1744 0 Miscellaneous - .0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 9014 1826 - 5802 0 Zone Conditioning - 8796 1826 - 5557 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 435 CFM 0 - 435 CFM 0 - Ventilation Load 200 CFM 909 147 200 CFM 9604 0 Supply Fan Load 435 CFM 0 - 435 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 9705 1973 - 15161 0 Central Cooling Coil - 9705 1973 - 0 0 Central Heating Coil - 0 - - 15161 - » Total Conditioning - 9705 1973 - 15161 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 27 of 31 • Air System Design Load Summary for 29 Fitness 301 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 28 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1500 COOLING OA DB / WB 82.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 165 ft2 4965 - 165 ft2 - - Wall Transmission 52 ft' 129 - 52 ft2 129 - Roof Transmission 0 ft2 0 - 0 ft' 0 - Window Transmission 165 ft2 203 - 165 ft2 2505 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 1303 ft2 121 - 1303 ft2 1498 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1303 W 4446 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 10 5250 9250 0 0 0 Infiltration - 447 -471 - 2935 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 15561 8779 - 7067 0 Zone Conditioning - 15172 8779 - 6390 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 746 CFM 0 - 746 CFM 0 - Ventilation Load 400 CFM 2470 -3139 400 CFM 19286 0 Supply Fan Load 746 CFM 0 - 746 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 17642 5640 - 25676 0 Central Cooling Coil - 17642 5642 - 0 0 Central Heating Coil - 0 - - 25676 - » Total Conditioning - 17642 5642 - 25676 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 28 of 31 Air System Design Load Summary for 30 Yoga 303 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 29 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1700 COOLING OA DB / WB 80.2 °F / 65.4 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 83 ft' 3125 - 83 ft' - - Wall Transmission 45 ft' 149 - 45 ft2 111 - Roof Transmission 0 ft' 0 - 0 ft' 0 - Window Transmission 83 ft' 79 - 83 ft' 1260 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 0 ft' 0 - 0 ft' 0 - Floor Transmission 521 ft2 38 - 521 ft' 599 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 521 W 1778 - 0 0 - Task Lighting 0 W 0 - 0 0 Electric Equipment 0 W 0 - 0 0 - People 12 3540 5460 0 0 0 Infiltration - 132 -182 - 1174 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 8841 5278 - 3144 0 Zone Conditioning - 8696 5278 - 3150 0 Plenum Wall Load 0% 0 - 0 0 Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 417 CFM 0 - 417 CFM 0 - Ventilation Load 400 CFM 1679 -3029 400 CFM 19410 0 Supply Fan Load 417 CFM 0 - 417 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 10375 2249 - 22560 0 Central Cooling Coil - 10375 2249 - 0 0 Central Heating Coil - 0 - - 22560 - » Total Conditioning - 10375 2249 - 22560 0 Key: Positive values are clg Toads Negative values are htg Toads Positive values are htg Toads Negative values are clg loads Hourly Analysis Program v4.60 Page 29 of 31 Air System Design Load Summary for 31 Dining/Kitchen/Flex Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 30 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1700 COOLING OA DB / WB 79.2°F/65.4°F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0°F/19.2°F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 248 ft2 6969 - 248 ft2 - - Wall Transmission 127 ft2 274 - 127 ft2 314 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 248 ft2 154 - 248 ft2 3765 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 1460 ft2 69 - 1460 ft2 1679 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1460 W 4981 - 0 0 - Task Lighting 0 W 0 - 0 ' 0 - Electric Equipment 0 W 0 - 0 0 - People 32 7360 3840 0 0 0 Infiltration - 298 91 - 3289 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 20105 3931 - 9047 0 Zone Conditioning - 19551 3931 - 8974 0 Plenum Wall Load 0% 0 0 0 - Pienum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 946 CFM 0 - 946 CFM 0 - Ventilation Load 650 CFM 2020 878 650 CFM 31416 0 Supply Fan Load 946 CFM 0 - 946 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 21571 4808 - 40390 0 Central Cooling Coil - 21571 4809 - 0 0 Central Heating Coil - 0 - - 40390 - » Total Conditioning - 21571 4809 - 40390 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 30 of 31 Air System Design Load Summary for 32 Salon 315 Project Name: Broadstone Sterling South Center Prepared by: Ocean Park Mechanical 12/19/2017 02:09PM Hourly Analysis Program v4.60 Page 31 of 31 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 82.0 °F / 66.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 24.0 °F 119.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft' 0 - 0 ft2 - - Wall Transmission 0 ft' 0 - 0 ft' 0 - Roof Transmission 0 ft' 0 - 0 ft' 0 - Window Transmission 0 ft2 0 - 0 ft' 0 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 0 ft' 0 - 0 ft' 0 - Floor Transmission 286 ft' 27 - 286 ft' 329 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft2 0 - Overhead Lighting 286 W 976 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 4 920 480 0 0 0 Infiltration - 98 -39 - 644 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 2020 441 - 973 0 Zone Conditioning - 1991 441 - 1021 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 150 CFM 0 - 150 CFM 0 - Ventilation Load 150 CFM 997 -441 150 CFM 7292 0 Supply Fan Load 150 CFM 0 - 150 CFM 0 - Space Fan Coil Fans - 0 - - 0 . - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 2988 0 - 8313 0 Central Cooling Coil - 2988 0 - 0 0 Central Heating Coil - 0 - - 8313 - » Total Conditioning - 2988 0 - 8313 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 31 of 31 FILE- 2015 Washington State Energy Code Compliance Forms December 19, 2017 Issued for Mechanical Permit Sterling Southcent 415 Baker Boulevard Tukwila, WA 98188 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 23 2018 City of Tukwila BUILDING DIVISION C MD OCEAN PARK MECHANICAL RECEIVED CITY OF TUKWILA #283 - 14900 Inter Urban Avenue Seattle, WA 98168 Ph: (206) 674-4553 DEC 21 2017 Fax: (206) 674-4564 PERMIT CENTER 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary 2015 Washington State Energy Code Compliance MECH-SUM Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Information Project Title: 415 Baker Boulevard Date 12/19/2017, Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Dept. Use Company Name: Ocean Park Mechanical Company Address: #283, 14900 Inter Urban Ave, Seattle, WA 98168 Applicant Name: Darren Lowe Applicant Phone: 206-674-4553 Project Description Briefly describe mechanical systems in the text box provided ❑ Total Bldg Performance (TBP) This path includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required. el New Building I Building Addition ❑ Tenant Improvement • System Retrofit I No System Changes Design Load Calculations heating, cooling or includes all applicable .i Load calculation summary ❑ MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building ventilating needs. if a load calculation summary is provided with the permit documents that compliance information then the MECH-LOAD-CALC form is not required. Mechanical Schedules 0 Mechanical Plans ❑ MECH-EQ Forms (TBD) Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, however, include on plans all applicable compliance information listed in MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate fire station occupancies) air in a manner that does heating or cooling is required. Exception 1) of DOAS (C403.6, Exception library or fire station) C402.4.1.4 with 100% of .i DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no ❑ Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (C403.6, 'J Ventilation and space conditioning provided by a HEVAV system per C403.7 in lieu 2) ❑ DOAS included in project, although not required (occupancy not office, retail, education, 0 DOAS related allowances included in project: ❑ Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area in building served by DOAS. QException to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power ❑ Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. exceeds 5hp. 5 horsepower threshold. • For one or more systems, the total fan motor nameplate hp of all fans in HVAC system If yes, provide a seperate MECH-FANSYS form for each HVAC system exceeding the Refer to Section C403.2.11 and MECH-FANSYS-DOC for requirements and exceptions. HVAC Hydronic Systems ❑ Hydronic chilled water ❑ Water -loop heat pump ❑ Hydronic heating water ❑ Geothermal .r No hydronic systems C406 Additional Efficiency Options - Mechanical ❑ C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than minimum requirements. All stand alone supply, retum, and exhaust fans over 1hp must have FEQ z 71 and must be selected within 10% of maximum total or static pressure. ❑ C406.6 Dedicated outdoor air system (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 that delivers required ventilation air in a manner that does not require space conditioning fan operation. ❑ C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% of annual hot water energy use be provided by heat pump, waste heat recovery or solar water -heating systems. 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary, pg. 2 MECH-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Service Water Heating Systems Equipment Type (s) ❑ Hot water heating tank(s) ❑ Instantaneous ❑ No service water systems ❑ Heat exchange from space heat boiler or central hot water/steam ❑ On -demand Dedicated boiler Distribution Type (s) Circulation System Commissioning Commissioning is required for: per C408.2 shall be performed requirements: of all mechanical heating. Mechanical water heating not required. water heating systems per C408.4 , systems regardless of individual equipment capacity. systems in the building do not exceed 240,000 Btu/h commissioning not required. does not exceed 200,000 Btu/h. Service water heating .1 Mechanical systems J Service If required, commissioning Exceptions to commissioning ❑ Total output capacity cooling or 300,000 Btu/h ❑ Capacity of largest service systems commissioning for all applicable space conditioning systems system in building Low Energy and Semi -Heated Spaces (Note 6 and 7) Space Type Location in Plan(s) Space(s) Served • Area Served, square feet Heating Capacity, Btu/h (Note 4) Cooling Capacity, Btu/h (Note 5) Peak Space Conditioning Capacity, Btu/h-sf Compliance Check Notes Note 4 - Provide total installed heating ou put capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. En er 0 if no cooling. Note 6 - Refer to Section C402.1.1 Low Energy Building. Intalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h"sf. Note 7 - Refer to Section C402.1.1.1 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 Btu/h'sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 2015 Washin.ton State Ener. Code Com fiance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa.e 3 of 15 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Equipment - Sizing, Performance and Type NA C403.1 Exempt process equipment Identify equipment to be used in manufacturing, industrial or commercial processes that do not provide space conditioning; identify provisions applicable to this equipment per C403.1 exception ' Yes C403.2.1 Load calculations Provide load calculations performed per ASHRAE Std 183 or equivalent, using design parameters per C302 and Appendix C; include load adjustments to account for energy recovery Carrier Hourly Analysis Version 4.6 used to calculate heating/ cooling loads. Yes C403.2.2 Equipment and system sizing Indicate that output capacities of heating and cooling equipment and systems are no greater than the smallest available equipment size that exceeds the calculated loads; note exceptions taken Smallest size is used. Yes C403.2.3 .2.3.2 C403.2.3.2 C403.2.13.1 HVAC equipment performance requirements (efficiency) Provide equipment schedules on plans or complete MECH-EQ forms indicating type, capacity, rated and WSEC minimum efficiencies for all heating and cooling equipment; include supply and OSA cfms and operating hours for all air systems; identify heating and cooling equipment that does not have a corresponding WSEC minimum efficiency (manufacturer rated) M0.1 and M0.2 Yes C405.8 C403.2.14 Electric motor efficiency List all motors z 1/12 hp (that are not integral to a rated piece of equipment) in the mechanical or electrical equipment schedules on plans; indicate hp, rpm, number of poles and rated efficiency, or exception applied M0.1 For fractional hp motors (1/12 - 1 hp), indicate whether they are an electronically commutated motor, have rated efficiency of at least 70%, or exception taken M0.1 NA C403.2.11.1 Fan power limitation For all HVAC fan systems that provide heating and / or cooling, provide system total nameplate hp in MECH-FANSYS-SUM form HVAC fans are < 5 hp. For all applicable HVAC systems with total fan motor hp > 5hp, verify fan system motor hp or bhp complies with fan power limits per equations in Table C403.2.11.1(1), provide MECH- FANSYS form for each system HVAC fans are < 5 hp. NA C403.2.11.2 Motor nameplate hp For all applicable HVAC systems with total fan motor hp > 5hp, indicate fan motors specified are the smallest available motor hp size greater than fan bhp, note exceptions taken NA C403.2.11.3 Fan efficiency For all applicable HVAC systems with total fan motor hp > 5hp, identify in equipment schedule all fans required to comply with fan efficiency grade and indicate rated FEG is z 67, or exception taken; indicate these fans are sized so total efficiency is within 15% of the fan maximum total efficiency Yes C403.2.11.4 Group R occupancy exhaust fan efficacy For all exhaust fans < 400 cfm in Group R occupancies, indicate in equipment schedule the fan flow rate and efficacy (cfm/watt), or exception taken; refer to Table C403.2.11.4 (CE -57) EF -1M0.1. andFans EF -2. NA C403.2.13 Variable flow capacity - fans For fan motors z 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for an HVAC system refer to HVAC System Controls for additional requirements NA C403.2.3 Maximum air cooled chiller capacity For chilled water plants and buildings with > 500 tons of cooling capacity, indicate air-cooled chiller capacity is a 100 tons, or exception taken NA C403.4 Large capacity cooling systems For buildings with z 300 tons of cooling capacity, indicate method of multi -stage or variable capacity control (VSD, multiple staged compressors, or max capacity of any single unit < 66% of the total) NA C403.2.3.1 Non-standard water-cooled centrifugal chillers For water-cooled centrifugal chillers not designed for operation at standard conditions, provide calculations documenting maximum full load and part load rated equipment performance requirements NA C403.2.13.1 C403.4.3.2 Centrifugal fan open -circuit cooling towers For open -circuit centrifugal fan cooling towers with z 1,100 gpm capacity, indicate cooling towers comply with efficiency requirements for axial fan open circuit cooling towers NA C403.4.2 C403.4.2.5 Large capacity boiler systems For single boilers with > 500,000 Btu/h capacity, indicate multi -stage or modulating burner or For boiler system(singlemultiple)with > 1,000,000 Btu/h y capacity, y, indicate turndown ratio per Table C403.4.2.5 and method (multiple single input boilers, modulating boilers, or combination) NA C403.2.13 Variable flow capacity - pumps For pump motors z 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in equipment schedule, or exception taken; for equivalent method for a hydronic system refer to Hydronic System Controls for additional requirements NA C403.2.3 Gas and oil -fired forced air furnace and unit heaters For forced air furnaces with capacity z 225,000 Btu/h and all unit heaters, indicate in equipment schedule intermittent ignition or IID, flue or draft damper, and rated jacket loss Yes C403.2.4.8 Combustion heating equipment For combustion heating equipment with output capacity > 225,000 Btu/h, indicate modulating or staged combustion control MUA-R-1 and MUA-R 2 have modulating combustion control. 2015 Washin•ton State Ener• Code Com •fiance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa•e 4 of 15 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Yes C403.2.3.3 Packaged electric heating / cooling equipment Verify all packaged electric equipment with > 6,000 Btu/h cooling capacity and any amount of heating is a heat pump; include in equipment schedules All cooling equipment is heat pump. M0.2 NA C403.2.12 Heating outside a building Indicate systems providing heating in non -enclosed outdoor occupied spaces are radiant systems; refer to HVAC System Controls for additional requirements NA C403.2.7.1 Kitchen exhaust hoods Indicate on plans the type, duty and exhaust air rate of each kitchen hood, refer to HVAC System Controls for additional requirements Yes C403.2.4.3 Outdoor supply air, exhaust and relief dampers Indicate locations of OSA intake, and exhaust and relief outlet dampers on plans; indicate whether dampers are Class 1 motorized, or gravity and exception taken (include leakage rating, cfm/sf); refer to HVAC System Controls for additional requirements for OSA dampers Floor plans show locations of MD. Legend on M0.0 specifies it to be class 1. Yes C403.2.4.3 Retum air dampers Indicate locations of retum air dampers that are integral to economizer operation; verify dampers are motorized; indicate whether dampers are Class 1, or within packaged equipment eligible for leakage rating exception (include leakage rating, cfm/sf) Floor plans. Yes C403.2.4.3 Stairway and shaft vent dampers Indicate location of stairway and shaft vent dampers on plans; verify dampers are Class 1 motorized; refer to HVAC System Controls for additional requirements NA C403.2.4.4 Zone isolation dampers • For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; identify isolation zone areas on plans and locations of associated isolation dampers in HVAC distribution system; refer to HVAC System Controls for additional requirements NA C403.2.3.4 Humidification For cooling systems with humidification equipment that are also required to have air economizer, indicate humidifier is adiabatic (direct evaporative or fog atomization), or exception taken Additional Efficiency Package Option, More Efficient HVAC Equipment & Fan Performance - Must comply with all 3 provisions to be eligible NA C406.2.1 C403.2.3 HVAC system selection To comply with additional efficiency package option, calculate the percentage of heating and cooling equipment in the project (based on output capacity) that do not have a corresponding WSEC listed efficiency; shall be less than 10% to comply NA C406.2.2 C403.2.3 Minimum equipment efficiency To comply with additional efficiency package option, indicate that all listed heating and cooling equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% NA C406.2.3 C403.2.11.3 Minimum fan efficiency To comply with additional efficiency package option, indicate rated FEG of stand alone fans is >_ 71; indicate these fans are sized so the fan efficiency at design conditions is within 10% of the maximum total or static efficiency HVAC System Controls Yes C403.2.4.1 Thermostatic controls (thermostats and humidistats) Indicate locations of thermostatic and humidity control devices and the zones they serve on plans, including perimeter system zones Floor plans show tstat locations. Where adjacent (neighboring) zones are controlled by separate thermostats (including perimeter systems used to offset heat gain or loss), and are connected by permanent openings > 10% of either zone sf area, indicate controls configured to prevent adjacent zones from operating in conflicting modes (one in heat, other in cool); applies to adjacent perimeter zones, adjacent nonperimeter zones, and adjacent perimeter and nonperimeter zones M1.2 to M1.7 - note #2 specifies that electric heat shall not operate when VTHP-# is cooling. If applying Exception 2 to nonperimeter zones adjacent to perimeter zones, indicate that setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature in that zone is 5°F higher than the adjacent perimeter zone temperature in heating Yes C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating operation with compression as the first stage of heating and supplemental heating controlled with outdoor lock -out temperature set to 40°F or less Note 1 on Cooling Units Motor List on M0.2. Yes C403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that control both heating and cooling Note 8 on Cooling Units Motor List on M0.2. 2015 Washin ton State Ener Code Com *Hance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa.e 5 of 15 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.2.4.1.3 Setpoint overlap restriction (thermostats) If separate heating and cooling systems with separate thermostatic control devices are used to serve a zone, indicate locations of both thermostatic control devices and the zone they serve on plans Indicate a limit switch, mechanical stop or DDC control with programming to prevent simultaneous heating and cooling Yes C403.2.4.2 C403.2.4.2.1 C403.2.4.2.2 Automatic setback and shutdown Indicate zone thermostatic controls configured with required automatic setback and manual override functions, setback temperatures, and control method (automatic time clock or programmable controls); note exceptions taken Yes C403.2.4.2.3 Automatic (optimum) start Indicate system controls that adjust equipment start time required to bring each area served up to design temperature just prior to scheduled occupancy Yes C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment operation; not including economizer cooling, night flush or IMC required OSA / exhaust Yes C403.2.4.3 Stairway and shaft vent dampers Indicate method of activation of stairway and shaft vent dampers (fire alarm or interruption of power) NA C403.2.4.4 Zone isolation controls For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that are expected to be occupied non -simultaneously; indicate controls that allow for independent space conditioning of isolation zones; or exception taken NA C403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off heating system when area served is unoccupied NA C403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation is falling, and when outdoor air temperature exceeds 40°F NA C403.2.4.6 Freeze protection system controls Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F, or conditions protect fluid from freezing NA C403.2.4.9 Group R1 hotel / motel guest rooms For hotels and motels with over 50 guest rooms, indicate automatic controls serving guest rooms that are capable of setback (heating) and set-up (cooling) of temperature setpoint by at least 5°F; indicate control method - activated by room entry or occupancy sensor 2015 Washin.ton State Ener. Code Com.liance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa.e 6 of 15 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Yesunits, C403.2.4.10 C403.2.4.11 Group R2 / R3 dwelling Group R2 sleeping units For primary space conditioning system, indicate 5-2 programmable thermostats capable of two setback periods per day; for all thermostats indicate purpose (heating only, cooling only, or both), required temperature range and at minimum a 10°F deadband; or exception taken M0.2 for t'stat for VTHP-1 to 3. Yes C403.2.6 C403.2.11.4 Ventilation Indicate method of ventilation air delivery (natural or mechanical) for each zone Mechanical If mechanically delivered, indicate that systems are configured to provide not more than 150% of, but at least the minimum required volume of outdoor air to each zone per IMC, ASHRAE 62.1 or other applicable code (WAC, OSHA, etc); or exception taken M0.0 for ventilation calculation. If delivered via natural ventilation, identify required elements per IMC including minimum openable area to the outdoors or qualifying adjoining spaces Yes C403.2.6.2 Demand controlled ventilation Identify spaces > 500 sf with occupant load > 25 people/1,000 sf per IMC; for each space indicate whether it is served by an HVAC system with total design OSA > 3,000 cfm, and / or the system has airside economizer or automatic modulating OSA damper; indicate OSA controls are configured toprovide demand controlled ventilation orprovide supporting 9 PP 9 documentation for applied exception This only applies to FC -3. Thermostat with CO2 sensor, and will adjust outdoor air damper. NA C403.2.6.3 Occupancy sensors For gyms, classrooms, auditoriums and conference rooms > 500 sf, indicate occupancy -based OSA control when space is unoccupied and method (closes OSA damper or shuts -off equipment); or alternate means provided to automatically reduce OSA when space is partially occupied NA C403.2.6.4 0403.2.6.4.1 Enclosed loading dock ventilation For enclosed loading docks, indicate ventilation / exhaust system method of activation (gas detection system for CO and NO2, or occupancy sensors), and control method (staged or modulating) Yes C403.2.6.4 C403.2.6.4.2 Enclosed parking garage ventilation For enclosed parking garages, indicate ventilation / exhaust system activated by gas detection system for CO and NO2, and control method (staged or modulating); or exception taken CO and NO2 sensors. DDC system will control transfer fans and adjust exhaust fan VFDs. NA C403.2.7.1 Kitchen exhaust hoods Provide calculations that show a balanced accounting of total kitchen exhaust (include all hoods) with % of: supply air, transfer air from adjacent spaces, and make-up air; if applicable, indicate that direct make-up air to each hood does not exceed 10% of hood exhaust For kitchens with total hood exhaust exceeding 2,000 cfm, indicate exhaust air rate per Table C403.2.7.1 and compliance method (DCV, energy recovery, or transfer air that would otherwise be exhausted) NA C403.2.7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements NA C403.2.13 Variable flow capacity - HVAC system fans For HVAC fan motors z 7.5 hp, indicate method of variable flow control (VSD, or equivalent control method that reduces design air volume by 50% at 1/3 static design pressure); note exception taken NA C403.3.1 DX air handler variable cooling control (Under Integrated Economizer) For DX air handlers with economizer and cooling capacity s_ 65,000 Btu/h, indicate number of cooling stages provided and method (multiple compressors and / or variable speed compressors); indicate minimum displacement (capacity reduction) as % of full load Indicate control method (cooling capacity controlled in response to space temperature, space temperature controlled by modulating supply airflow, or both) NA C403.2.11.5 Fan airflow control For DX air handling units with cooling capacity >_ 65,000 Btu/h and evaporative and chilled water air handling units with fan 5_ 0.25 hp, indicate whether system is single zone or multiple zone and related control method (cooling capacity controlled in response to space temperature, space temperature is controlled by modulating supply airflow, or both) For mechanical cooling systems (includes DX and chilled water coils) that control cooling capacity in response to space temperature - Provide a minimum of two stages of fan control; indicate minimum fan speed is s 66% of full speed drawing 5 40% of full speed fan power during periods of low cooling or ventilation only For other mechanical cooling systems (includes DX and chilled water coils) that control space temperature by modulating airflow (in lieu of, or in addition to, controlling capacity in response to space temperature) - Provide fan controls for modulating supply airflow; indicate minimum fan speed is 5 50% of full speed drawing s 30% of full speed fan power during periods of low cooling or ventilation only; or exception taken NA 0403.2.4.12 DDC system capabilities Provide central and zone level DDC controls as required based on system application, capacity or size thresholds and other qualification per Table 0403.2.4.12.1 Identify all DDC system input / output control points; indicate capability for trending and graphical display Ducting Systems 2015 Washin.ton State Ener. Code Com.liance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa.e 7 of 15 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 'Project Title: 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Yes C403.2.8.1 C403.2.8.3 Duct construction Indicate on plans that all ductwork is constructed and sealed per IMC M0.0 - 2015 WSEC - NOTES NOTE #8. For OSA ductwork, also indicate on plans that ductwork meets air leakage requirements per C402.5 and vapor retarder requirements per the IBC M0.0 - 2015 WSEC NOTES - NOTE #8. Yes C403.2.8.3 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans M0.0 - GENERAL NOTES - NOTE #14. NA C403.2.8.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed 2015 Washin.ton State Ener. Code Com.liance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa.e 8 of 15 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Yes C403.2.8.1 C403.2.8.2 Duct insulation For supply and retum ductwork located in unconditioned space or outdoors, indicate R -value of insulation on ductwork on plans; identify climate zone; note exceptions taken M0.0 - 2015 WSEC NOTES - NOTE #6. For supply ductwork located in conditioned space, identify if design supply temperature is < 55°F or > 105°F and indicate R -value of insulation on this ductwork on plans; note exception taken M0.0- 2015 WSEC NOTES - NOTE #6. For OSA ductwork, shafts and plenums, indicate R -value of insulation on these elements on plans per Table C402.1.3 for steel -framed walls; note exception taken MO.0 - 2015 WSEC NOTES - NOTE #7. Piping Systems NA C403.2.9 Piping insulation Indicate design temperature range of fluid conveyed in piping and thickness of insulation (in inches) on hydronic piping plans; or exception taken NA C403.2.9.1 Piping insulation exposed to weather Indicate method of protection of pipe insulation from damage / degradation on hydronic piping plans Economizers Yes C403.3 Air economizer required Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring air economizer controls M0.0 - "Outdoor Air Economize rs" specifies all of the equipment with economizer s. Provide MECH-ECONO form indicating systems utilizing air economizer exceptions, including those with water -side economizer in lieu of air economizer; indicate on plans eligible exception(s) taken and measures to comply with exception(s) M0.0 - "Outdoor Air Economize m" specifies the exceptions used. Yes C403.3.1 Integrated economizer operation - air and water Indicate air and water -side economizers are configured for partial cooling operation even where additional mechanical cooling is required to meet the load NA C403.3.2 Economizer heating system impact - air and water Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation Yes C403.3.3.1 Air economizer capacity Indicate modulating OSA and return air dampers are configured to provide up to 100% OSA for cooling 100% OSA for FC -2 to 9. Yes C403.3.1 C403.3.3.2 Integrated air economizer Verify mechanical cooling controls are interlocked with air economizer controls so the outside air damper remains in 100% open position when mechanical cooling is also required to meet the cooling load, until the leaving air temperature is < 45°F For systems with cooling capacity 65,000 Btu/h, verify that control of economizer dampers is not based only on mixed air temperature; or exception taken NA Yes C403.3.3.3 Air economizer high limit controls Indicate high limit shut-off control method and required high limit per Table C403.3.3.3 High limit of 75 °F. NA C403.3.4.1 Water economizer capacity For eligible systems where water -side economizer may be provided in lieu of air economizer, indicate system is capable of 100% design cooling capacity at 50°F db / 45°F wb OSA temperatures NA C403.3.4.2 Water economizer maximum pressure drop Indicate pressure drop across precooling coils and heat exchangers in water economizer system do not exceed pressure drop limit NA C403.3.1 DX air handling equipment control For DX air handlers with economizer and cooling capacity >_ 65,000 Btu/h, refer to HVAC System Controls for requirements NA C403.2.4.7 DX equipment economizer fault detection and diagnostics For DX air handlers with economizer and cooling capacity z 54,000 Btu/h, provide a fault detection and diagnostics (FDD) system to monitor economizer system operation and report faults Systems Requiring Energy Recovery NA C403.5.1 Energy recovery (ER) - ventilation / exhaust systems For systems with design OSA > 5,000 cfm, or design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations For rooms served by multiple systems with aggregate design OSA > 5,000 cfm, or aggregate design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations 2015 Washin ton State Ener Code Com •fiance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa .e 9 of 15 • • Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes Indicate ER rated effectiveness that increases OSA enthalpy by z 50% based on delta between OSA and return air enthalpies at design conditions NA C403.2.7.2 Laboratory exhaust systems (energy recovery) For buildings with total lab exhaust > 5,000 cfm, indicate method of energy recovery used to pre -condition laboratory make-up air; ER effectiveness (min 25°F); or alternative method per exception (VAV exhaust, semi -conditioned makeup, or CERM calculation) NA C404.10.4 (under C404.11) Pools and permanent spas exhaust systems (energy recovery) For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER method and use of waste heat (preheat ventilation air, pool water or service hot water); or exception taken Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by 2 36°F NA C403.5.2 Energy recovery - steam condensate systems For buildings with on-site steam heating systems, indicate condensate water ER For buildings that use off-site generated steam where condensate is not returned to the source, indicate on-site condensate water ER 2015 Washin.ton State Ener. Code Com.liance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa.e 10 of 15 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: • 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA 0403.5.3 Energy recovery - cooler / freezer condensers For buildings with food service, meat or deli departments that have z 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy (service water heating, space heating, or dehumidification reheating) For buildings with > 40,000 sf conditioned floor area and with 5 1,000,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy for service water heating and also for space heating, or dehumidification reheating NA 0403.5.4 Energy recovery - condenser systems For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and design service hot water load > 250,000 Btu/h, indicate condenser ER to pre -heat service water; or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 85°F). Hydronic System Controls NA C403.2.13 C403.4.2.7 Variable flow control - hydronic system pumps For hydronic system pump motors 5 7.5 hp, indicate method of variable flow control (VSD or equivalent method that requires 5 30% design wattage at 50% design fluid flow); note exception taken Identify whether hydronic coils have DDC controls and associated manner of pump speed control (differential pressure, zone hydronic demand, etc) NA 0403.2.5 0403.4.2.4 Hydronic system setback and part load controls For boilers that provide building heating, indicate controls that provide heating water temperature setback based on outdoor temperature For heating and chilled water systems 5 300,000 Btu/h, indicate systems are configured to automatically reset supply water temperature based upon demand; or exception taken. If system pump motor hp a 3 hp, also indicate controls automatically reduce flow by >_ 50%. For chilled water systems (>_ 300,000 Btu/h, pump motor hp >_ 3 hp) that serve water-cooled unitary air conditioners, indicate VSD or staged pumps in chilled water system and heat rejection loop that reduce pump flow so that one control valve is nearly wide open, or to maintain a minimum differential pressure; or exception taken NA C403.4.2 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers NA 0403.4.6 Hot gas bypass limitation For cooling equipment with hot gas bypass, provide either multiple step unloading or continuous capacity modulation; indicate bypass capacity per Table C403.4.6 NA 0403.4.2.2 Two -pipe changeover systems Indicate changeover deadband (min 15°F), heating / cooling mode scheduling and changeover temperature range (limit 30°F) NA 0403.4.2.6 Chiller / boiler plant pump isolation Indicate controls are configured to automatically reduce overall plant flow and shut-off flow through individual chillers and boilers when not in use NA 0403.2.13.1.1 C403.4.3.1.1 C403.4.3.1.2 Heat rejection equipment - variable flow control For cooling towers with fan motors >_ 7.5 hp, indicate VSD and method to adjust fan speed (adjusted based on leaving fluid temperature or condenser temperature / pressure of heat rejection device) For multiple -cell heat rejection equipment with VSD, indicate controls that ramp all fans in unison NA C403.4.3.3 Heat rejection equipment - cooling tower flow turndown Indicate open -circuit cooling towers with multiple pumps or VSD control are designed so all cells can be run in parallel NA C403.4.2.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide minimum 20°F water supply temperature deadband between heat rejection and heat addition modes; or exception taken NA C403.4.2.3.2.1 Water loop heat pump - heat rejection equipment, Zone 4 Indicate type of cooling tower (open- or closed-circuit) in equipment schedule; indicate method used to limit system heat loss when heat rejection is not needed NA C403.4.2.3.2.2 Water loop heat pump - heat rejection equipment, Zone 5 For open- or closed-circuit cooling towers, provide a heat exchanger that separates the cooling tower and heat pump loop NA C403.4.2.3.3 Water loop heat pump - isolation valves For hydronic heat pump systems with total system power > 10 hp, indicate 2 -way isolation valves on each heat pump and variable flow system control Dedicated Outdoor Air Systems (DOAS) - Optional through 6/30/16, Prescriptive 7/1/2016 Yes C403.6 C403.6.3 Dedicated outdoor air systems For buildings with office, retail, education, library and fire station spaces, identify these spaces on plans; indicate that ventilation air in each occupied space is provided via a DOAS system; or document compliance with C403.6.3 Impracticality; or exception taken (buildings complying with C402.4.1.4 or C406.6 may not utilize exceptions) Yes C403.6.1 Energy recovery ventilation with DOASefficiency For all DOAS systems, indicate exhaust air ER method; or exception taken with supporting calculations. Indicate ER rated effectiveness that increases OSA enthalpyb > 50% based on y delta between OSA and return air enthalpies at design conditions. HRV-1 has a thermal of 66% Yes 0403.6.2 Heating / cooling system controls with DOAS Indicate equipment associated with the delivery of zone level heating and cooling (fans, hydronic pumps, primary air dampers, etc) are configured to shut off, and central equipment is configured to turn down, when there is no call for heating or cooling in the zone they serve FC -1 and IHP-4 will cycle to maintain temperatur e setpoints. If applying Exception to heating / cooling fans used for air mixing in the space during deadband periods, include fan watts per cfm in equipment schedule 2015 Washin.ton State Ener Code Com.liance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa.e 11 of 15 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C402.4.1.4 C403.6 Increased prescriptive maximum vertical fenestration area with DOAS Indicate that all occupied, conditioned spaces are served by a DOAS per C403.6 Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) NA C406.6 Building provided with DOAS To comply with additional efficiency package option, indicate that 90% or more of all occupied, conditioned spaces are served by a DOAS per C403.6 Multiple Zone Air Systems NA C403.4.4 Air systems serving multiple zones Identify supply air systems serving multiple zones and the zones they serve on plans; indicate whether system is VAV and method of primary air control; or provide supporting documentation for applied exception to VAV NA C403.4.4 VAV systems serving multiple zones Provide equipment schedules on plans or MECH-EQ form that list all VAV air terminals and types For each air terminal include: maximum airflow rates for primary supply air during zone peak heating and zone peak cooling; maximum airflow during reheating, recooling or mixing; minimum airflow rate to maintain required ventilation, and the basis for these values; if IMC or ASHRAE 62.1 multiple zone equation is basis for minimum flow rates, provide calculation on plans NA C403.4.4.1 Single duct VAV terminal units Indicate single duct terminal units are configured to reduce primary supply air before reheating or recooling NA C403.4.4.2 Dual duct systems - terminal units For systems with separate warm air and cool air ducts, indicate terminal units are configured to reduce the flow from one duct to minimum before mixing with air from the other duct NA C403.4.1.1 C403.4.1.2 VAV system static pressure sensors - sensors and DDC set points Indicate locations of duct static pressure sensors on plans; include at least one sensor per major duct branch; verify controller setpoint pressure at each sensor is 5 1.2 inch w.g. For systems with zone level DDC, indicate controls are configured to monitor zone damper positions and reset static pressure setpoint based on the zone requiring most pressure; include control logic that automatically detects and generates an alarm if any zone excessively drives reset logic, and allows building operators to exclude zones from reset logic NA C403.4.4.3 Multiple -zone VAV system ventilation optimization controls For systems with zone level DDC controls, indicate controls are configured to automatically reduce outdoor airflow in response to changes in system ventilation efficiency; or exception taken NA C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or outdoor air temperature; or exception taken Multiple Zone HVAC Systems, High Efficiency VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply with all 16 provisions NA C403.7, Item 1 Air economizer Indicate system is configured for 100% air economizer operation and complies with all related economizer requirements per C403.3 (without economizer exceptions) NA C403.7, Item 2 Direct digital controls (DDC) Provide DDC controls for all components of system; identify all DDC system input / output control points; indicate capability for trending and graphical display NA C403.7, Item 3 Outdoor airflow measurement and reduction For systems with minimum OSA > 2,500 cfm, indicate outdoor airflow monitoring station that measures OSA intake under all load conditions; indicate control sequence that increases or reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency (per C403.4.4.3 without exceptions) or DCV (per C403.2.6.2) NA C403.7, Item 4 Supply airflow measurement For systems with minimum OSA > 2,500 cfm, indicate supply airflow monitoring station capable of measuring supply air delivered to VAV terminals under all load conditions NA C403.7, Item 5 Zone isolation and maximum area served Verify maximum area served by a single HEVAV system is 5 50,000 sf, or one entire floor, whichever is greater; in addition if a system serves > 25,000 sf, that includes areas that are expected to be occupied non -simultaneously, indicate zone isolation controls per C403.2.4.4 NA C403.7, Item 6 Interior / exterior zone design supply air temperature Verify that VAV terminals serving interior cooling driven loads are sized per design supply air temperature that is 5°F higher than VAV terminals serving exterior zones NA C403.7, Item 7 Maximum air terminal inlet velocity Identify air terminals with minimum primary airflow setpoints > 50% of maximum setpoint in equipment schedule or MECH-EQ form; indicate air terminal inlet velocity does not exceed 900 fpm NA C403.7, Item 8 Sequence of operation Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC 36 NA C403.7, Item 9 Maximum allowable system brake horsepower Verify fan system bhp is 5 90% of the bhp limit per Option 2 equation in Table C403.2.11.1(1), provide MECH-FANSYS form for each system NA C403.7, Item 10 Fan -powered terminal unit motor and control Indicate all series and parallel terminal fans have electronically commutated motors; indicate DDC control system is configured to vary air terminal fan speed as a function of the load; indicate fan speed during periods of low heating, low cooling, or ventilation only is 5 66% of peak design air flow or provide supporting documentation for applied exception 2015 Washin.ton State Ener Code Com.liance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa•e 12 of 15 Mechanical Permit Plans Checklist MECH-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable (yes,no,na) Code Section Code Provision Information Required - Must be in permit documents Location in Documents Building Department Notes NA C403.7, Item 11 Application of single duct and fan -powered terminal units Indicate VAV terminal types on plans; verify fan -powered terminal units only serve perimeter zones with envelope loads; verify all other zones are served by single duct terminal units NA C403.7, Item 12 Fan -powered terminal unit primary air reset Indicate DDC controls are configured to automatically reset the primary supply air cfm setpoint of all fan -powered terminal units to the minimum required to maintain ventilation during occupied heating or deadband, based upon the VAV air handling unit OSA ventilation fraction NA C403.7, Item 13 High occupancy space controls For spaces > 150 sf with occupant density z 25 people / 1000 sf, indicate space is served by a dedicated terminal unit with DCV control that resets terminal unit ventilation setpoint; also indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by >_ 5°F NA C403.7, Item 14 Dedicated HVAC systems For server, electronic equipment, telecom or similar spaces with cooling loads > 5 W/sf, indicate spaces are served by independent HVAC systems that are separate from HPVAV systems serving rest of building; indicate dedicated HVAC systems have air economizer controls or energy recovery per C403.3 Exception 9 NA C403.7, Item 15 Central plant efficiency Indicate whether systems are served by a high efficiency heating water plant, or a high efficiency chilled water plant If complying via high efficiency heating water plant: Indicate all VAV terminals have hydronic heating coils served by heating water system with either gas-fired boiler(s) with thermal efficiency >_ 90%, air -to -water heat pumps, or heat recovery chillers If complying via high efficiency chilled water plant: Indicate all VAV air handlers have cooling coils served by chillers with rated IPLV efficiency that exceeds WSEC listed IPLV by at least 25% per Table C403.2.3(7) (note water-cooled IPLV is max, all others are min); indicate smallest chiller or compressor in plant is <_ 20% of total plant capacity, or provide thermal storage sized for s 20% of total plant capacity NA C403.7, Item 16 Fault detection and diagnostics Indicate DDC system includes a fault detection and diagnostics (FDD) system configured to monitor operation and provide fault reporting of required parameters for all VAV air handlers and VAV air terminal units in the HPVAV system HVAC Equipment Energy Use Metering NA C409.3.1 HVAC equipment energy use metering For new buildings > 50,000 sf and building additions > 25,000 sf, verify energy use metering of all equipment used to provide space heating and cooling, dehumidification and ventilation will be provided per C409; indicate equipment eligible for exception Documentation and System Specific Requirement To Support Commissioning Yes C408.2 Scope of mechanical systems commissioning Indicate that all mechanical systems, equipment, and controls for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; M0.0 2015 WSEC NOTES - NOTE #3. For buildings with >_ 240,000 Btu/h total output cooling capacity or >_ 300,000 Btu/h total output heating capacity, indicate that all mechanical systems regardless of individual capacity are required to be commissioned; or provide building heating / cooling capacity calculation demonstrating eligibility for exception Yes C403.2.10 0408.1.1 0408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate in plans and specifications that Cx per C408 is required for all applicable mechanical systems; M0.0 2015 WSEC NOTES - NOTE #3. Include general summary with at a minimum of Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final mechanical inspection. Yes C408.2.2 Air system and hydronic system balancing Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances defined in the specifications; indicate systems shall be balanced in a manner to first minimize throttling losses, then adjusted to meet design flow conditions M0.0 2015 WSEC NOTES - NOTE #2. Yes C408.2.2.1 Air system balancing devices Indicate devices that provide the capability to balance all supply air outlets, zone terminals and air handling equipment requiring system balancing Grilles will have opposed blade balance dampers. NA C408.2.2.2 Hydronic system balancing devices Indicate devices that provide the capability to isolate, balance and measure flow across all hydronic equipment requiring system balancing including heating and cooling coils and pumps Yes 0408.2.3 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems M0.0 2015 WSEC NOTES - NOTE #9. Project Close Out Documentation 2015 Washin.ton State Ener. Code Com•liance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Pa.e 13 of 15 Mechanical Permit Plans Checklist MECH-CHK ' 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 415 Baker Boulevard Date 12/19/2017 The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Section Code Provision Information Required Must be in documents Location in Building Department (yes,no,na) - permit Documents Notes Documentation and project Indicate in plans that project close out documentation and training of building operations personnel is required for all mechanical components, equipment and systems govemed by M0.0 2015 WSEC Yes C103.6 close out submittal requirements this code; indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance forms and calculations NOTES - NOTE #10. 2015 Washin ton State Ener. Code Com.liance Forms for Commercial R2 and R3 over 3 stories and all R1 • Economizer Exceptions MECH-ECONO 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: 415 Baker Boulevard Date 12/19/2017 All cooling systems shall be configured to provide air economizer operation, regardless of system capacity, for new construction and mechanical system alterations. Various exceptions to this requirement are available. Identify all systems that an economizer exception will be applied to and additional information as noted below. For Building Dept. Use Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS Exp 1 Cooling equipment serving spaces that are provided with a dedicated outdoor air system (DOAS) per C403.6. Spaces served shall have year- round design cooling loads from lights and equipment less than 5 watts per square foot. System ID Lighting + Equipment Loads (W/sf) FC-1/HP-1 1 IHP-3/OHP-3 1 IHP-4/OHP-4 1 Exp 2 Single zone unitary or package systems with dehumidification that affect other systems such that air economizer would increase energy consumption. System ID Exp 3 High efficiency single zone unitary or packaged systems. Equipment cooling efficiency shall be better than the WSEC required minimum efficiency by at least 64% in Climate Zone 4C and 59% in Climate Zone 5B per Table C403.3. System ID Exp 4 Equipment that provides hydronic chilled water for chilled beams and chilled ceiling systems that is served by a water economizer system per C403.3.4 in lieu of air economizer. System ID Exp 5 Water -source heat pumps with heat recovery. Heat pump efficiency shall be 15% better than WSEC required minimum efficiency. Provide at minimum 60% air economizer. Energy recovery to preheat OSA shall have at least 50% effectiveness. Additional system requirements apply. System ID Exp 6 Cooling equipment serving Group R occupancies. Per unit limit is less than 20,000 Btu/h cooling capacity for equipment installed outdoors or in a mech room adjacent to the outdoors. For cooling equipment installed in other locations the unit limit is less than 54,000 Btu/h. Efficiency shall be 15% better than WSEC required minimum efficiency. System ID Equipment Location Cooling Capacity (Btu/h) IHP-1/OHP-1 Outdoor 19,200 IHP-2/OHP-2 Outdoor 19,200 Exp 7 Variable refrigerant flow (VRF) systems with energy recovery. Outdoor unit shall be a reverse -cycle heat pump with variable speed compressor(s) and condenser fan(s). Outdoor unit cooling capacity shall be not less than 65,000 Btu/h. Energy recovery to preheat outdoor air shall have at least 50% rated effectiveness. System shall be capable of providing simultaneous heating and cooling by tranferring recovered energy from zone(s) in cooling mode to other zone(s) that are in heating mode. Outdoor Unit System ID Cooling Capacity (Btu/h) Exp 8 Cooling equipment serving Controlled Plant Growth Environments. Equipment cooling efficiency shall be better than WSEC required minimum efficiency by at least 20%. Not eligible: unitary and applied heat pumps. System ID SEER, EER, & IEER Exp 9 Cooling equipment with energy recovery. Spaces served shall have year-round design cooling loads from lights and equipment greater than 5 watts per square foot. Energy recovery system shall utilize recovered energy for on-site space heating or preheating of service hot water. Provide calculations to the code official that demonstrate the amount of recovered energy used for on-site heating purposes is equivalent to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID Lighting + Equipment Loads (W/sf) 2015 Washin ton State Ener. Code Com.liance Forms for Commercial R2 and R3 over 3 stories and all R1 Economizer Exceptions, cont. MECH-ECONO 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised January 2017 Project Title: Date 12/19/2017 Economizer Exception Summary Refer to Section C403.3 for descriptions of economizer provisions and exceptions. For alterations refer to Section C503.4 and Table C503.4. ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS, CONTINUED Exp 10 Cooling equipment for dedicated server, electronic equipment or telecom switch rooms. Per building limit for this exception is 240,000 Btu/h cooling capacity or 10% of required building air economizer capacity, whichever is greater. Part load control required over 85,000 Btu/h. Additional requirements apply. Option a - Cooling equipment efficiency shall be 15% better than the WSEC required minimum efficiency.. Option b - Waterside economizer required. Cooling equipment efficiency shall be 5% better than the WSEC required minimum efficiency. Option c - Waterside economizer required. All cooling equipment is subject to ASHARE Standard 127. System ID Compliance Option Cooling Capacity (Btu/h) IHP-5/OHP-5 Option a 18,200 IHP-6/OHP-6 Option a 18,200 Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 240 kBtu/h): Alternate Exp 10 Capacity Limit: 36,400 ECONOMIZER EXCEPTIONS - MECHANICAL SYSTEM ALTERATIONS OR REPLACEMENT C503.4 Pre -approved design altemative to full compliance with air economizer Exp 1 requirement. An alternative for mechanical system alterations where existing building constraints make full compliance with air economizer requirement impractical. Provide calculations to the code official that demonstrate the proposed alternate design strategy provides similar energy savings to the annual energy that would be saved by the cooling system with air economizer per C403.3. System ID Alt. Strategy ECONOMIZER EXCEPTIONS - SIMPLE SYSTEMS Cooling C503.4 Qualifying small equipment. Per unit limit less than 33,000 Btu/h. Per System ID Capacity Exp 2 building limit for this exception is 72,000 Btu/h cooling capacity or 5% of (Btu/h) required building air economizer capacity, whichever is greater. Cooling equipment efficiency shall be 15% better than WSEC required minimum efficiency. Not eligible: non -unitary equipment, unitary equipment installed outdoors or in mech room adjacent to outdoors, equipment installed during new construction, shell -and -core construction, or initial tenant improvement. Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 72,000 Btu/h): Alternate C503.4 Exp 2 Capacity Limit: C503.4 Equipment that provides hydronic chilled water for chilled water terminal Exp 3 units. Equipment part load cooling efficiency (IPLV) shall be better than WSEC required minimum efficiency by at least 25%. Per building limit for this exception is 480,000 Btu/h cooling capacity or 20% of required building air economizer capacity, whichever is greater. Chilled water terminal units serving Group R occupancies are not included in the building capacity total. System ID Cooling Capacity (Btu/h) Total Claimed Exempt Capacity: Total building air economizer capacity (if claimed > 480,000 Btu/h): Alternate C503.4 Exp 3 Capacity Limit: Table Compliance Options for alteration or replacement of existing C503.4 mechanical cooling equipment per Table C503.4. Refer to table and all applicable table footnotes for full requirements. Applies to the following retrofit conditions: Option a - Any new or replacement equipment Option b - Replacement equipment of same type with same or smaller cooling output capacity. Option c - Replacement equipment of same type with large cooling output capacity. Option d - New equipment added to existing system or replacement equipment that is different than existing being replaced. System ID Equipment Type Compliance Path 4 _DC! Er1G1fEERS o Seattle o Portland Spokane San Diego Austin Irvine -"o Eugene San Francisco Anchorage STRUCTURAL CALCULATIONS STERLING SOUTHCENTER SUPPLEMENTAL MECHANICAL CALCULATIONS Prepared for: Urbal Architecture 1938 Fairview Avenue East, Suite 100 Seattle, WA 98102 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 232018 City of Tukwila I BUILDING DIVISION December 11, 2017 DCI Job Number 17041-0175.00 t117OZOI 601 W. Riverside, Suite 600 NMI NMI NMI CITY OF TUKWILA DEC 21 2017 PERMIT CENTER Spokane, Washington, 99201 Phone (509) 455-4448 S e r v i c e Innovation Value =uLI EfIGIfIEERS Project -rERL.1 N/6 0 L)- 4 Project No. 1701/ 1 -Cat -S Sheet No. Date Subject `,tee k.! -,v-0 �G.r h 1MGt�Cf 50s t -so -e?. G&A,L m E C?/L (4s .x cue 6 I � --loo (b s Muq-R-1 : to as Ibeke z 1"luA-R-17 lc.)a-S Ib S �1. `1 61 lbs cam, = f o 132 L-16Its 5 .S7-- 14 o.,1oo 16S 0I- 2,100 Fp- -`e,p SDs '" 7 2e c - LQ I"t2v - _K b 1. G SD $ J- P' up MvA- 1015 11 -Ds. •�� S� ( �� to1S ®� 6,1 31- f6t ►bs 0:_L61 - 16 Ibs Mcoc 1x► 9GD (go 1bs Si 7-Y0 d 7-8 1.6s i-'\. 1 c — cloc, 1 tos By EfGIfIEERS 111°..1111111121.E111115.11gm D CI Project No. Sheet No. Project Date Subject By MuA Sec_ I = 63-0 I hs ✓Lr y�U lhs Asp OecL6 lamed = to as 16s. ac", 3-0Ibs — [UaS�hs�►� 1a12S Iv JAS /firo UvE21(..,2tiI iIVv M �x Oot ti - aGO lbs pL � 2-25 I hs SEtS . Setsv- _ A NG H-0fL4Ca r = CL1, 34" L.. /1 S2- 121 Aso U_K 2 �8 (�2 leo Ibs U� I Li61 - 7, S -. 1.9c -.14 1b o VEPT✓121./I ti/v Ibs- � �A � = 180 11'7A---/ • � � s At ST_ DCI EfIGIfIEERS Project No. Sheet No. Project Date Subject By u f'J O O ` e faT o 1244 HO - S L- ISM ►C. STRA-t� (1A -sr- s ..?► S (k S,tsD 'k' dt< E N! u AT . A,1- (-- 610:A/76 1\1OYF SI -RUC -1'u RAL.. 1,v L 1 I:tC_wDt✓ PLA 1\-1 NorF S QEC i F )NG S► 2A i� (2g -z 2 /-n C/.►T. NOTE: ROOF TRUSS AT SIMILAR CONDITION. r L fROOF JOIST PER PLAN W/ SIMPSON H2.5A TO BRG WALL ON EA END OF JOISTS BELOW UNIT LUS46 HGR, TYP 4x6 BLKG AT CURB, TYP PLAN A -A C MECH UNIT CURB PER SUPP 3/8"0 LAG REW EMBED 2' NTO JOIST OR BLKG AT EA CORNER OF CURB 4x6 BLKG OR JOIST WHERE OCCURS MECHANICAL UNIT ATTACHMENT SCALE: 1" = 1'-0" -`)FORTE MEMBER REPORT rOOF MECH SUPPORT, BLKG PASSED 1 piece(s) 4 x 6 Douglas Fir -Larch No. 1 Overall Length: 2' 7" j0 0 All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs) 269 @ 2" Total 3347 (2.25") Passed (8%) -- 1.0 D + 0.7 E (All Spans) Shear (lbs) 166 @ 9" 1 1/4" Rim Board 2079 Passed (8%) 0.90 1.0 D (All Spans) Moment (Ft -lbs) 139 @ 1' 1 1/4" Rim Board 1720 Passed (8%) 0.90 1.0 D (All Spans) Live Load Defl. (in) -0.001 @ 1' 3 1/8" 0.056 Passed (L/999+) -- 0.6 D - 0.7 E (All Spans) Total Load Defl. (in) 0.002 @ 1' 3 1/8" 0.112 Passed (L/999+) -- 1.0 D + 0.7 E (All Spans) • Deflection criteria: LL (1/480) and TL (L/240). • Top Edge Bracing (Lu): Top compression edge must be braced at 2' 5" o/c unless detailed otherwise. • Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 2' 5" o/c unless detailed otherwise. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (lbs) Accessories Total Available Required Dead. Seismic Total 1 - Stud wall - SPF 3.50" 2.25" 1.50" 169 142/-142 311/-142 1 1/4" Rim Board 2 - Stud wall - SPF 3.50" 2.25" 1.50" 102 83/-83 185/-83 1 1/4" Rim Board • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software Is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC E5 under technical reports ESR -1153 and ESR -1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and Installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator Forte Software Operator Job Notes Tributary Dead Seismic Loads Location (Side) Width (0.90) (1.60) Comments 0 - Self Weight (PLF) 1 1/4" to 2' 5 3/4" N/A 4.9 1 - Point (Ib) 1' (Front) N/A 260 225 Residential -Living Areas Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software Is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC E5 under technical reports ESR -1153 and ESR -1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and Installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator Forte Software Operator Job Notes Anthony Sorentino DCI Engineers (509) 455-4448 asorentino@dci-engineers.com System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD SUSTAINABLE FORESTRY INITIATIVE 12/8/2017 10:39:04 AM Forte v5.3, Design Engine: V7.0.0.5 Sterling TJ1.4te Page 1 of 1 F O R T E, MEMBER REPORT rOOFMECHSUPPORT, Floor: Joist 1 piece(s) 9 1/2" TJI® 230 @ 24" OC 0 Overall Length: 28' 10 1/2" All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal. 0 Design Results .. Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs) 1880 @ 13' 5 1/4" 2772 (3.50") Passed (68%) 1.15 1.0 D + 1.0 S (All Spans) Shear (lbs) 984 @ 13' 7" 1682 Passed (59%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft -lbs) -2851 @ 13' 5 1/4" 3830 Passed (74%) 1.15 1.0 D + 1.0 5 (All Spans) Live Load Defl. (in) 0.207 @ 21' 6 3/8" 0.381 Passed ( L/885) -- 1.0 D + 0.525E + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in) 0.423 @ 21' 0.761 Passed (L/432) -- 1.0 D + 0.525E + 0.75 L + 0.75 S (Alt Spans) TJ -Pro'" Rating 29 30 Failed •\ -- -- • Deflection criteria: LL (L/480) and TL (L/240). • Top Edge Bracing (Lu): Top compression edge must be braced at 4' 8" o/c unless detailed otherwise. NOTE TJI RATING NOT • Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 4' 4" o/c unless detailed otherwise. REQUIRED DURING • A structural analysis of the deck has not been performed. SEISMIC LOADING • Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge"' Panel (24" Span Rating) that is glue • Additional considerations for the TJ-ProTM Rating include: None System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD Supports Bearing Length Loads to Supports (lbs Accessories Total Available Required Dead Snow Seismic Total 1 - Stud wall - SPF 3.50" 2.25" 1.75" 106 328 35/-35 469/-35 1 1/4" Rim Board 2 - Stud wall - SPF 3.50" 3.50" 3.50" 809 1071 237/-237 2117/-237 None 3 - Stud wall - SPF 3.50" 2.25" 1.75" 298 388 99/-99 785/-99 1 1/4" Rim Board • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR -1153 and ESR -1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator Forte Software Operator Job Notes Anthony Sorentino DCI Engineers (509) 455-4448 asorentino@dci-engineers.com Dead Snow Seismic Loads Location (Side) Spacing (0.90) (1.15) (1.60) Comments 1 - Uniform (PSF) 0 to 28' 10 1/2" 24" 15.0 30.0 Residential -Living Areas 2 - Uniform (PLF) 19' to 21' N/A 173.0 - 150.0 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR -1153 and ESR -1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator Forte Software Operator Job Notes Anthony Sorentino DCI Engineers (509) 455-4448 asorentino@dci-engineers.com SUSTAINABLE FORESTRY INITIATIVE 12/8/2017 10:42:30 AM Forte v5.3, Design Engine: V7.0.0.5 Sterling TJI.4te Page 1 of 1 lai] F C- R T E 0 SOLUTIONS REPORT rOOF MECH SUPPORT, Floor: Flush Beam PASSED Current Solution: : 3 piece(s) 2 x 6 Douglas Fir -Larch No. 2 Overall Length: 6' 7" 1 tJ 6' Li 0 All locations are measured from the outside face of left support (or left cantilever end).AII dimensions are horizontal.; Drawing is Conceptual Design Results Actual @ Location -Allowed Result LDF Member Reaction (lbs) 799 @ 6' 5" 4303 R.25") Passed (19%) -- Shear (lbs) 761 @ 5' 10" 2970 Passed (26%) 1.00 Moment (Ft -lbs) 1643 @ 3' 4 5/8" 2212 Passed (74%) 1.00 Live Load Defl. (in) 0.014 @ 3' 3 3/8" 0.156 Passed (L/999+) -- Total Load Defl. (in) 0.110 @ 3'3 11/16" 0.313 Passed (L/679) -- 0 System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD ;AH Product Solutions Depth Series Plies Wood Volume 5 1/2" 2 x Douglas Fir -Larch No. 2 3 39.60 The purpose of this report is for product comparison only. Load and support information necessary for professional design review is not displayed here. Please print an individual Member Report for submittal purposes. Forte Software Operator Job Notes Anthony Sorentino DCI Engineers (509) 455-4448 asorentino@dci-engineers.com 1 2/8/201 7 10:49:11 AM Forte v5.3, Design Engine: V7.0.0.5 Sterling TJI.4te Page 1 of 1 3 1t1 ACOUST"ILS December 20, 2017 Darren Lowe Ocean Park Mechanical 14900 Interurban Ave #283 Seattle, WA 98168 241 SOUTH LANDER STREET, SurtE 200 SEATTLE, WA 98134 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 23 2018 City of Tukwila BUILDING DIVISION (206) 792-7796 www.a3acoustics.com RE: Property Line Noise Analysis Broadstone Sterling Southcenter -- 415 Baker Boulevard, Tukwila, WA This letter presents the results of an environmental noise analysis conducted for the Broadstone Sterling Southcenter project located at 415 Baker Boulevard in Tukwila, WA. The purpose of the analysis is to document the impact of the proposed mechanical equipment to the adjacent receiving properties. Noise levels generated by the equipment are predicted to receiving properties and compared to the exterior sound level limits established by Tukwila Municipal Code. This analysis is based on the Mechanical Review drawings dated 12/20/2017. ZONING The project site is bounded by Baker Boulevard to the north, Andover Park E. to the east, a high-rise multifamily residential building to the south and a low-rise commercial property to the west. Per the City of Tukwila, it is our understanding the project and adjacent properties are currently zoned as TUC-TOD. As per Tukwila Municipal Code Section 8.22.020.8, TUC is classified as a commercial -zoned district. The following figure is a zoning map with the project site highlighted in yellow, Figure 1. MI7 0201 RECEIVED CITY OF TUKWILA DEC 21 2017 PERMIT CENTER Page 2 of 11 Figure 1 - Project Site Zoning Map Page 3 of 11 NOISE ORDINANCE The applicable noise ordinance is described by the City of Tukwila Municipal Code chapter 8.22.050, Maximum Permissible Sound Levels, The City of Tukwila noise limits are based on the zoning of the source and receiving properties. The maximum. permissible sound levels for the City of Tukwila are provided in the following table. Table 1 — Exterior Soun District of Sound Source District of Receiving Property Residential Daytime (dB(A)) Residential Nighttime (dB(A)) Commercial (dB(A)) Industrial (dB(A)) Residential 55 45 57 60 Commercial 57 47 60 65 Industrial 60 50 65 70 In addition, during any hour of the day or night the applicable noise limitations may be exceeded for any receiving property by no more than: (a) 5 dB(A) for a total of 15 minutes in any one-hour period; or (b) 10 dB(A) for a total of 5 minutes in any one-hour period; or (c) 15 dB(A) for a total of 1.5 minutes in any one-hour period. Based on the zoning of the source and receiver properties, noise from the mechanical system cannot exceed 60 dBA to the receiving property lines in each direction. Page 4 of 11 EQUIPMENT The equipment evaluated for compliance is listed in the table below which also presents the sound power levels provided by the manufacturer. It is our understanding that this is the extent of the equipment exposed to the neighboring property lines. Table 2 — Equipment Sound Power Levels, Lw (re 1 picowatt jnIt IakelModel CU -R-1 Carrier 24ABB360-62 Sound Power Level (dBA) 79 MUA-R-1 Sterling PV25A2B01J63P2AB5 78 E F -R-4 PennBarry DX08B 64 OHP -5 LG LSU180HSV4 60* EF -R-3 PennBarry DX08B 67 EF -R-2 PennBarry DX08B 67 EF -R-1 PennBarry DX11 B 65 OHP -6 LG LSU180HSV4 60* MUA-R-2 Sterling PV25A2B01 J63P2AB5 75 CU -R-2 Carrier 24ABB360-62 79 GEF -2-1 PennBarry BHM42B 83 GEF -2-2 PennBarry BHM42B 83 GEF -2-3 PennBarry BHM42B 83 * Sound power level based on manufacturer's sound pressure level at 3ft. We understand that the following equipment is only used in the event of an emergency and, therefore, is exempt from the code limits: • SPF -R-1,2,3 • EPF-R-1,2 • SEF -R-1,2,3 Page 5of11 METHODS Equipment noise was predicted to the nearest neighboring property lines based on a point source noise propagation model, the point is defined as the center of the unit. Methods employed followed those described by the Air -Conditioning & Refrigeration Institute (ARI) Standard 275 and ASHRAE Applications Handbook. The receiving property points that were used for all equipment calculations are shown in Figure 2 below with an arrow. Receiver I: Receiver Description: Zoning: Noise Limit: Receiver II: Receiver Description: Zoning: Noise Limit: Receiver ID: Receiver Description: Zoning: Noise Limit: Receiver IV: Receiver Description: Zoning: Noise Limit: North Property Lowrise Commercial Commercial 60 dB(A) East Property Lowrise Commercial Commercial 60 dB(A) South Property Highrise Residential Commercial 60 dB(A) West Property Lowrise Commercial Commercial 60 dB(A) Page 6 of 11 BAKER BLVD RECEIVER I: NORTH (ACROSS BAKER BLVD) RECEIVER IV: WEST PROJECT SITE 4 • RECEIVER II: SOUTH f 4 tER PARKE. RECEIVER II: EAST (ACROSS ANDOVER PARK) Figure 2 — Receiver Locations Page 7of11 RESULTS Noise levels from the proposed equipment have been predicted to the following adjacent properties. The calculations have been optimized to sum adjacent equipment to a single point source. The following tables provide results of our predictions to the nearest properties. North Receiving Property Line Table 3 — Predicted Noise Levels: North Property Line - Mechanical Equipment Noise Transmission to North Property Line Source LwA Loss/Distance(ft) Barrier Loss Additional Losses dB(A) 1 MUA-R-1 78 -38 (109') 0 0 40 1 CU -R-1 79 -39 (110') 0 0 40 1 EF -R-4 64 -39 (120') 0 0 25 1 OHP -5 60 -40 (125') 0 0 21 Combined LP at Property Line (dBA) 43 As shown in Table 3, the sound pressure level from the equipment as currently designed meets the exterior sound level goal of 60 dB(A). Page 8of11 East Receivin_q Property Line Table 4 — Predicted Noise Levels: East Property Line — Mechanical Equipment Noise Transmission to East Property Line Source LwA Loss/Distance(ft) Barrier Loss Additional Losses dB(A) 1 MUA-R-1 78 -42 (162') 0 0 36 1 CU -R-1 79 -41 (147') 0 0 38 1 EF -R-4 64 -41 (142') 0 0 23 1 OHP -5 60 -40 (128') 0 0 20 1 OHP -6 60 -40 (129') 0 0 20 1 MUA-R-2 75 -39 (115') 0 0 36 1 CU -R-2 79 -39 (120') 0 0 40 1 EF -R-1 65 -41 (149') 0 0 24 1 EF -R-2 67 -41 (149') 0 0 26 1 EF -R-3 67 -41 (149') 0 0 26 Combined LP at Property Line (dBA) 44 As shown in Table 4, the sound pressure level from the equipment as currently designed meets the exterior sound level goal of 60 dB(A). Page 9 of 11 South Receiving Property Line Table 5 — Predicted Noise Levels: South Property Line — Mechanical Equipment Noise Transmission to South Property Line Source LwA Loss/Distance(ft) Barrier Loss Additional Losses dB(A) 1 OHP -6 60 -35 (72') 0 0 25 1 MUA-R-2 75 -33 (61') 0 0 42 1 CU -R-2 79 -32 (53') 0 0 47 1 EF -R-1 65 -33 (61') 0 0 32 1 EF -R-2 67 -34 (65') 0 0 33 1 EF -R-3 67 -34 (68') 0 0 33 Combined Lp at Property Line (dBA) 48 Table 6 — Predicted Noise Levels: South Property Line — Ground Level Mechanical Equipment Noise Transmission to South Property Line Ground Level Source LwA Loss/Distance(ft) Barrier Loss Additional Losses dB(A) 1 GEF -2-1 83 -24 (20') 0 -3*, -12** 44 1 GEF -2-2 83 -24 (20') 0 -3*, -12** 44 1 GEF -2-3 83 -24 (20') 0 -3*, -12** 44 Combined Lp at Property Line (dBA) 49 * Loss due to louvered opening ** Loss due to 10ft of 2" thick duct lining downstream of fan, as shown in the drawings. As shown in Table 5 and Table 6, the sound pressure level from the equipment as currently designed meets the exterior sound level goal of 60 dB(A). Page 10 of 11 West Receiving Property Line Table 7 — Predicted Noise Levels: West Property Line - Mechanica Equipment Noise Transmission to West Property Line Source LwA Loss/Distance(ft) Barrier Loss Additional Losses dB(A) 1 MUA-R-1 78 -40 (125') 0 0 38 1 CU -R-1 79 -41 (144') 0 0 38 1 EF -R-4 64 -41 (149') 0 0 23 1 OHP -5 60 -42 (165') 0 0 18 1 OHP -6 60 -42 (165') 0 0 18 1 MUA-R-2 75 -42 (173') 0 0 33 1 CU -R-2 79 -42 (172') 0 0 37 1 EF -R-1 65 -41 (143') 0 0 24 1 EF -R-2 67 -41 (143') 0 0 26 1 EF -R-3 67 -41 (143') 0 0 26 Combined LP at Property Line (dBA) 43 As shown in Table 7, the sound .pressure level from the equipment as currently designed meets the exterior sound level goal of 60 dB(A). SUMMARY This letter shows that the environmental noise from the mechanical equipment at the Broadstone Sterling Southcenter project will meet the City of Tukwila noise ordinance. This document has provided our environmental noise analysis to the nearest receiving properties from the proposed units at 415 Baker Boulevard in Tukwila, Washington. Should there be questions, please do not hesitate to contact us. Sincerely, A3 ACOUSTICS, LLP MATT ROE, PE PARTNER & ACOUSTICAL CONSULTANT A3 ACOUSTICS, LLP 241 SOUTH LANDER STREET, SUITE 200 SEATTLE, WA 98134 (206) 745-2202 — C (206) 489-5183 — 0 Page 11 of 11 Appendix A. Descriptors To better understand this report we present a brief overview regarding sound properties, descriptors and terms. dBA Mechanical noise is often measured as an A -weighted sound level in units of decibels, symbolized as dBA. The A -weighting is a specific weighting filter in a sound level meter that corresponds approximately to the sensitivity of human hearing at the various frequencies. Sound levels vary significantly depending on location and activities. People normally experience sound levels between about 30 and 90 dB(A), depending on their activity. For example, a nearby noisy vehicle, radio or power tool may produce 90 dB(A); normal conversation is about 55 to 65 dB(A); and a bedroom or quiet office is about 30 to 40 dB(A). The table below approximates human sensitivity to changes in sound level. Table 8 — Changes in Sound Level Change in Sound Level (dB) Change in Apparent Loudness 1 Imperceptible (except for tones) 3 Just barely perceptible 6 Clearly noticeable 10 About twice (or half) as loud 20 About 4 times (or one -forth) as loud City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director November 27, 2018 Terris Patterson 14900 Interurban Ave S, Ste 283 Tukwila, WA 98168 RE: Request for Extension #1 Permit Number M17-0201 Dear Mr. Patterson, This letter is in response to your written request for an extension to Permit M17-0201. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through May 21, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, VR1\1 Rachelle Ripley Permit Technician File: Permit No. M17-0201 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Rachelle Ripley From: Terris Patterson <Terris@oceanpm.com> Sent: Tuesday, November 20, 2018 12:22 PM To: Rachelle Ripley Subject: Extend M17-0201 /I I I.fill I\I\ A\ We need to please extend permit number M17-0201 since we're just now able to start mechanical installation. I am the POC for the project and please: Terris Patterson 206-588-5158 Terris@OceanPM.com Sent from my phone. All typos are the fault of the device, not the owner. CAUTION: This email originated from outside the City of Tukwila network. Please DO NOT open attachments or click links from an unknown or suspicious origin. Request for Extensior rent Expiration Date: `t Extension Request: Approved for ird days Denied (provide explanation) 1 # Signature:.:Initials 10/1/2018 City of Tukwila Department of Community Development DARREN LOWE 14900 INTERURBAN AVE S - SUITE 283 TUKWILA, WA 98168 RE: Permit No. M17-0201 STERLING SOUTHCENTER 407 BAKER BLVD Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/21/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/21/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperatio ' in this matter. Sincerely, WAN, Rachelle Ripley Permit Technician File No: M17-0201 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 IV1) OCEAN PARK MECHANICAL To: Project: Subject: City of Tukwila 6300 Southcenter Boulevard Suite #100 Tukwila, WA 98188 Sterling Southcenter — 415 Baker Boulevard Mechanical Permit Application # M17-0201 Date: April 20, 2018 Response to Correction Letter #1 dated January 5, 2018 MECHANICAL DEPARTMENT — Allen Johannessen 206-433-7163 (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) OPM Response: The mechanical drawings were signed/sealed by a Professional Engineer; however, they did not include the date of signature. The updated plans include the date of signature. RECEIVED CITY OF TUKWILA APR 272018 PERMIT CENTER CORRECTION LTB# 283 - 14900 Inter Urban Avenue • Seattle, WA 98168 Telephone: (206) 674-4553 • Facsimile: (206) 674-4564 NVII-02-01 (BUILDING REVIEW NOTES) 1. Please provide manufacturers' documentation and installation documents for all new mechanical systems to include ventilation fan equipment, HVAC, heat pumps, smoke dampers, smoke control units and generator. OPM Response: Generator is supplied by the electrical contractor. Shop drawings of HVAC included. 2. Provide specific details to show how and where the smoke control air supply and exhaust vents are located to efficiently remove smoke from corridors.:(2015 IMC [F] 513.7 & IFC 909.7) OPM Response: The smoke control system is in accordance with Allen Engineering's Smoke Control Conceptual Report. The smoke control system (including mechanical, electrical, fire alarm, architectural) will be submitted to the City of Tukwila under a separate permit application. It includes stair and elevator pressurization, and exhaust of the fire floor via smoke exhaust fans SEF -R-1 to SEF -R-3. Drawing M0.3 specifies how equipment and dampers are controlled. Smoke Control Riser Diagram on Drawing M3.1 shows locations of the fans and dampers. 3. Provide specific details page for seismic mounts and anchoring specification of the ducts, pipes and mechanical equipment for this project. OPM Response: Refer to drawing M0.0 for the Acoustics Requirements which specifies how equipment will be supported. General Note #9 on drawing M0.0 updated as follows: All mechanical heating and ventilation equipment shall conform to SMACNA, ASHRAE, ASCE 7-10, local and state regulations for seismic restraint (including piping and ductwork). Refer to "acoustic requirements" on drawing M0.0 for equipment restraint. Vibro Acoustics shall submit shop drawings for all devices and provide calculations, certified by a Professional Engineer licensed in the State of Washington. After installation, Vibro Acoustics shall visit the site to verify that the vibration isolation systems are installed and operating properly. Vibro Acoustics shall verify that isolators are adjusted, with springs perpendicular to bases or housing, adjustment bolts are tightened up on equipment mountings, and hangers are not cocked. Hangers shall be installed as close to the structure as possible. Vibro Acoustics shall submit a sign -off letter, certified by a Professional Engineer licensed in the State of Washington. Page 2 of 3 4. Special inspections shall be required for smoke control systems, generator, bolting/anchoring and commissioning of systems. Provide notes and a matrix of special inspections required. OPM Response: Special inspection of smoke control systems:: Refer to note #1 — Special Inspections on drawing MO.O. Generator: The generator is supplied by the electrical contractor, who will have the supplier provide a startup report and a verification report. Bolting/anchoring: Vibro Acoustics is the special inspector for the isolation systems. Refer to response to item #3 above. Refer to note #2 — Special Inspections on drawing MO.O. Ocean Park Mechanical will commission the mechanical systems, as noted in 2015 Washington State Energy Code Notes — note #8 on drawing MO.O. 5. In addition to the stamp and signature the date of signature shall alsabe required on each plan sheet. See General Notes above. OPM Response: The updated plans include the date of signature. FIRE DEPARTMENT — Al Metzler 206-971-8718 A cursory review of this submittal indicates a partial inclusion of some smoke control equipment. An approved smoke control permit from the Tukwila Fire Marshal's Office is required before this mechanical permit can be approved by the Fire Marshal's Office. OPM Response: The smoke control consultant (Travis Allen of Allen Engineering) prepared the Smoke Control Conceptual Report. Smoke control drawings were submitted to the City of Tukwila and are approved. Sincerely, Ocea :_Park Mechanical Darren Lowe, PE Page 3 of 3 5/1/2018 City of Tukwila Department of Community Development DARREN LOWE 14900 INTERURBAN AVE S -SUITE 283 TUKWILA, WA 98168 RE: Permit Application No. M17-0201 STERLING SOUTHCENTER 415 BAKER BLVD Dear DARREN LOWE, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 12/21/2017, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of COMMENTS OUT and is due to expire on 6/21/2018. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M17-0201 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 January 05, 2018 City of Tukwila Department of Community Development DARREN LOWE 14900 INTERURBAN AVE S - SUITE 283 TUKWILA, WA 98168 RE: Correction Letter # 1 MECHANICAL Permit Application Number M17-0201 STERLING SOUTHCENTER - 415 BAKER BLVD Dear DARREN LOWE, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Please provide manufactures documentation and installation documents for all new mechanical systems to include ventilation fan equipment, HVAC, heat pumps, smoke dampers, smoke control units and generator. 2. Provide specific details to show how and where the smoke control air supply and exhaust vents are located to efficiently remove smoke from corridors. (2015 IMC [F] 513.7 & IFC 909.7) 3. Provide specific details page for seismic mounts and anchoring specification of the ducts, pipes and mechanical equipment for this project. 4. Special inspections shall be required for smoke control systems, generator, bolting/anchoring and commissioning of systems. Provide notes and a matrix of special inspections required. 5. In addition to the stamp and signature the date of signature shall also be required on each plan sheet. See General Notes above. Note: Contingent on response to these corrections, further plan review may request for additional corrections. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 FIRE - M DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. • A cursory review of this submittal indicates a partial inclusion of some smoke control equipment. An approved smoke control permit from the Tukwila Fire Marshal's Office is required before this mechanical permit can be approved by the Fire Marshal's Office. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely, achelle Ripley Permit Technician File No. M17-0201 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 r'ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0201. DATE: 03/26/19 PROJECT NAME: STERLING SOUTHCENTER SITE ADDRESS: 407 BAKER BLVD Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: A -J AV 3-2f'H'i Building Division II Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator 110 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/28/19 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 04/25/19 Approved Approved with Conditions ri Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED. Departments issued corrections: Bldg D Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0201 DATE: 05/02/18 PROJECT NAME: STERLING SOUTHCENTER 907 SITE ADDRESS: BAKER BLVD Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Atoc Building Division ArtA Aug, 5-'i-»-4 0 Public Works ❑ Fire Prevention Structural p Planning Division ❑ Permit Coordinator El El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/03/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/31/18 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 ERMIT COORD COPY.. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0201 DATE: 12/21/17 PROJECT NAME: STERLING SOUTHCENTER SITE ADDRESS: 415 BAKER BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: God t AM OW \\V Building Division Fire Prevention Public Works Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 12/26/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/23/18 Approved Corrections Required ❑ Approved with Conditions n ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fired Ping 0 PW 0 Staff Initials: 12/18/2013 PROJECT NAME: SITE ADDRESS: 1, Ay tbetfCr' PERMIT NO: ORIGINAL ISSUE DATE: 3----.43--/e REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS STAFF ISSUED DATE STAFF IN'IALS � _ l 41INIT��A�,S tt �� 161 Summary of Revision: c Aolvvle R, &'d - seer, j j c -'- Received by:4 �-f�� v REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.2ov REVISION SUBMITTAL RECEIVED AR 26 2019 COMMUNITY DEVELOPMENT Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 3f2i3 ( 2o1'1 Plan Check/Permit Number: M 1-7 - 01-d1 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: SZO Ai) Moe SrE-eLLING) Project Address: <Il `r 84-k eX_ Contact Person: fCi2t_LS ?if -770(441 Phone Number: 20(a S& 515-x, Summary of Revision: yuhek--p.c,o-- 24 x 20 " peorr +.) &u 1-4\-& att ) Cr tv ry! (t) 030 i ci cid / Thc 6.4 I 77 -4 -Ls /i iit-CA-1 Gid -VV= 1 r rr-t B r LL. (-( of vc il- 4-. awe,� l A-(-1 c- k'1 f N 12 -Pi 1 ' ( i Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisi c Received at the City of Tukwila Permit Center by: Entered in TRAKiT on )-01 W:\Permit Center \Templates\Forms \Revision Submittal Form doe Revised: August 2015 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4/2 2bL%-- Plan ChecWPermit Number: M 14- — 0201 ❑ Response to Incomplete Letter # ® Response to Correction Letter # / ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner O Deferred Submittal # Project Name: Sre21,1,1/4,.% 4ouTil Ge"*nbz — 4(f 64,44,77�Vvn z lam. Project Address: 4 t( i;P002 ISv) tAly Contact Person:7Mucc�-1 Lo.+' Phone Number: 7 -6,314-z1s-r3 ar_ 103 Summary of Revision: ?Zvi knikr hv(- RECEIVED CITY OF TUKWILA APR 2 7 2018 PERMIT CENTER Sheet Number(s): A1ti- PLL'`J "Cloud" or highlight all areas of revision includin date of Received at the City of Tukwila Permit Center by: Ef Entered in TRAKiT on W:\Permit Center (Brenda)\Forms'Permit Center Documents (Word)\Revision Submittal Form.doc Revised: August 2015 License #: BUS -0101045 UBI: 601880679 Issued Date: 01/01/2017 Expiration Date: 12/31/2017 Bus Lic OCEAN PARK MECHANICAL INC 14900 INTERURBAN AVE, #283 TUKWILA, WA 98168-4654 City of Tukwila Business License Nature of Business: Plumb/HVAC/Mech Contra Business Narne: OCEAN PARK MECHANICAL INC Business Address: 14900 INTERURBAN AVE, #283, TUKWILA, WA 98168-4654 t) FINANCE DIRECTOR LICENSEE AGREES TO COMPLY WITH ALL THE REQUIREMENTS OF CITY ORDINANCES AND STATE LAWS APPLICABLE TO THE BUSINESS ACTIVITY LICENSED HEREUNDER, This license Is to be displayed conspicuously at the location of business and is not transferrable or assignable. l Please note the following guidelines in the operation of your business: 1. It is necessary to contact the Finance Office at 206-431-3680 in the event your business: . Moves within the city limits of Tukwila . Moves outside the city limits . Ceases operation . Changes ownership . Changes use or type of operation . Will be having a special event (such as a tent sale, parking lot sale or any other event) outside its routine operation. 2. Additional licenses are required if your business has live music/entertainment, tow trucks, amusement devices, solicitors/peddlers, or adult entertainment. 3. Any retail sales tax generated in Tukwila needs to be reported to the Washington State Department of Revenue, under sales tax code # 1729. 4. Tukwila business license renewals are mailed to all licensed businesses in December and payable without penalty until January 31. Department of Labor and Industries PO Box 44450 Olympia, WA 98504-4450 OCEAN PARK MECHANICAL INC _Reg: CC-O0EANPM024M1 VW: 601-880-679 egjstered, asr;prt vided by Law as: .;Construction Contractor C01) GflNERAL OCEAN PARK MECHANICAL INC Eiectzve'Date 7121/1208 14900 INTERURBAN AVE S #283 SEATTLE WA 98168 Epii'atiott Date 7/I I/2018 t; OCEAN PARK MECHANICAL INC Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of kel Labor & Industries Search L&I Page 1 of 3 AftCti :A -l. Index Help My I.&t Workplace Rights Trades & Licensing OCEAN PARK MECHANICAL INC Owner or tradesperson Principals BOGLE & CO HENDRIX, RACHAEL, SECRETARY MARPLES, RACHAEL MARY CHRISTIN, MEMBER HENDRIX, ROGER NEIL, MEMBER HENDRIX, STEVE, TREASURER (End: 10/29/2002) Doing business as OCEAN PARK MECHANICAL INC WA UBI No. 601 880 679 14900 INTERURBAN AVE S #283 SEATTLE, WA 98168 206-674-4553 KING County. Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. OCEANPM024M1 Effective — expiration 07/21/1998— 07/11/2018 Bond No bond accounts during the previous 6 year period. Active. Meets current requirements. Insurance .._....._.................. Ohio Security Ins Co $1,000,000.00 Policy no. BLS53704374 Received by L&I Effective date 05/23/2017 06/01/2014 Expiration date 06/01/2018 Insurance history Savings (in lieu of bond) $12,000.00 Received by L&I Effective date 10/07/2014 10/07/2014 Release date Impaired date N/A N/A Savings account ID Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601880679&LIC=OCEANPM024M 1 &SAW= 5/25/2018 OCEAN PARK MECHANICAL INC Savings history Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ............................... _....... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. PBUJD00306 Issue date 06/14/2012 Violation city Seattle Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman, specialty or trainee certificate, temporary permit or medical gas endorsement as required. Contractor employed Antonio Ortega as a plumber without the proper certification. Infraction no. PBUJD00305 Issue date 06/14/2012 Violation city Seattle Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman, specialty or trainee certificate, temporary permit or medical gas endorsement as required. Contractor employed Kurtis Nelson as a plumber without the proper certification. Satisfied .......................... RCWIWAC 18.106.020 Violation amount $250.00 Satisfied ........................ RC W/WAC 18.106.020 Violation amount $250.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 959,477-00 ....... ...................... Doing business as OCEAN PARK MECHANICAL INC Estimated workers reported Quarter 1 of Year 2018 "Greater than 100 Workers" L&I account contact T3 / DAVID PRYOR (360)902-4804 - Email: PRYD235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........................................................ No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601880679&LIC=OCEANPM024M 1 &SAW= 5/25/2018 ACOUSTIC REQUIREMENTS UNIT UNIT DESCRIPTION EQUIPMENT SUPPORT DUCT CONNECTIONS MUA-R-1 AND 2 MAKE-UP AIR - CORRIDOR PRESSURIZATION SPRING ISOLATORS WITH 2" STATIC DEFLECTION. REFER TO NOTE 3. CU-R-1 AND 2 CONDENSING UNIT SPRING ISOLATORS WITH 1" STATIC DEFLECTION. REFER TO NOTE 4. HRV-1 LEVEL 1 OFFICE SUPPLY/ LEVEL 1 TOILET ROOM EXHAUST HRV DOUBLE DEFLECTION NEOPRENE MOUNTS HAVING 0.3" STATIC DEFLECTION. REFER TO NOTE 2. SPF-R-1 TO 3 STAR PRESSURIZATION FANS EMERGENCY EQUIPMENT. NO ISOLATION REQUIRED. EPF-R-1 AND 2 ELEVATOR PRESSURIZATION FANS EMERGENCY EQUIPMENT. NO ISOLATION REQUIRED. SEF-R-1 TO 3 SMOKE EXHAUST FANS EMERGENCY EQUIPMENT. NO ISOLATION REQUIRED. GEF-1-1 TO 1-3 GARAGE EXHAUST FANS SPRING ISOLATORS WITH 2" STATIC DEFLECTION. REFER TO NOTE 2. GEF-2-1 TO 2-3 GARAGE EXHAUST FANS SPRING ISOLATORS WITH 2" STATIC DEFLECTION. REFER TO NOTE 2. GTF-1-1 TO 1-7 GARAGE TRANSFER FANS RIGID ATTACHMENT GTF-1-8 GARAGE TRANSFER FAN DOUBLE DEFLECTION NEOPRENE MOUNTS HAVING 0.3" STATIC DEFLECTION. GTF-2-1 TO 2-6 GARAGE TRANSFER FANS RIGID ATTACHMENT SF-1-1 CATERING KITCHEN 120 SUPPLY FAN DOUBLE DEFLECTION NEOPRENE MOUNTS HAVING 0.3" STATIC DEFLECTION. REFER TO NOTE 2. EF-1-1 JANITORS CLOSET EXHAUST FAN REFER TO NOTE 2. EF-1-2 CATERING KITCHEN 120 EXHAUST FAN DOUBLE DEFLECTION NEOPRENE MOUNTS HAVING 0.3" STATIC DEFLECTION. REFER TO NOTE 2. EF-2-1 TOILET ROOM 219 EXHAUST FAN REFER TO NOTE 2. EF-2-2 HOUSEKEEPING CLOSET 218 EXHAUST FAN REFER TO NOTE 2. EF-2-3 TRASH ROOM 216 EXHAUST FAN REFER TO NOTE 2. EF-3-1 TOILET ROOM 341b EXHAUST FAN REFER TO NOTE 2. EF-3-2 SHOWER ROOM 349 EXHAUST FAN EF-R-1 TRASH CHUTE EXHAUST FAN REFER TO NOTE 1. REFER TO NOTE 2. EF-R-2 TRASH ROOM (LEVELS 3 TO 7) & SALON 340 EXHAUST FAN REFER TO NOTE 1. REFER TO NOTE 2. EF-R-3 DINING 308 / CHEF'S KITCHEN LOUNGE 306 EXHAUST FAN REFER TO NOTE 1. REFER TO NOTE 2. EF-R-4 MEN'S 348 / WOMEN'S 347 EXHAUST FAN REFER TO NOTE 1. REFER TO NOTE 2. EF-1 APARTMENT BATHROOM EXHAUST FAN REFER TO NOTE 2. EF-2 APARTMENT SECOND BATHROOM EXHAUST FAN REFER TO NOTE 2. TF-1 INTERIOR BEDROOM TRANSFER FAN FC-1 TO 9 VERTICAL FAN COIL UNIT (4) MASON 2"XL" SUPER W NEOPRENE PADS. ONE PER CORNER OF HEAT PUMP. REFER TO NOTE 2. HP-1 TO 9 HEAT PUMP MOUNTED IN GARAGE DOUBLE DEFLECTION NEOPRENE MOUNTS HAVING 0.3" STATIC DEFLECTION. IHP-# SPLIT SYSTEM AC UNIT - INDOOR UNIT OHP-# SPLIT SYSTEM AC UNIT - OUTDOOR UNIT DOUBLE DEFLECTION NEOPRENE MOUNTS HAVING 0.3" STATIC DEFLECTION. B-1 AND B-2 BOILERS 3/4" THICK NEOPRENE WAFFLE PADS STACKED TO HAVE 0.1" STATIC DEFLECTION. P-1 TO 3 CIRCULATION PUMPS 1/4" THICK CLOSED CELL NEOPRENE TAPE. ST-1 TO 3 DOMESTIC HOT WATER STORAGE TANK RIGIDLY ATTACHED TO STRUCTURE. ET-1 EXPANSION TANK RIGIDLY ATTACHED TO STRUCTURE. NOTES: 1. INSTALL UNIT ON FULL PERIMETER 1/4" NEOPRENE TAPE. MAKE ALL CONNECTIONS FROM THE FAN TO THE CURB USING NEOPRENE ISOLATION WASHER GROMMETS. 2. FLEXIBLE DUCT CONNECTIONS TO EQUIPMENT. 3. FLEXIBLE DUCT CONNECTIONS TO EQUIPMENT. 2" DUCT LINER ON ROOF; 1" DUCT LINER WITHIN BUILDING TO FIRST GRILLE. 4. FLEXIBLE PIPING CONNECTIONS. END OF SCHEDULE OUTDOOR AIR ECONOMIZERS SYSTEM FC-1 FC-2 FC-3 FC-4 FC-5 FC-6 FC-7 FC-8 FC-9 NOTES; LOCATION OFFICES LEVEL 1 GREAT ROOM 104 BISTRO 103/LOBBY 102 READING ROOM/LOUNGE 214 GAME ROOM 211 THEATRE 210 FITNESS 345 YOGA 344 MINIMUM OUTDOOR AIR 300 CFM FROM HRV-1 700 CFM 750 CFM 150 CFM 150 CFM 200 CFM 400 CFM 400 CFM DINING 342/KITCHEN 343/FLEX 341 650 CFM 100% OUTDOOR AIR ECONOMIZER 1,600 CFM 2,000 CFM 600 CFM 800 CFM 600 CFM 1,200 CFM 600 CFM 1,200 CFM 1. FC-2 TO FC-9 SHALL INCORPORATE 100% OUTDOOR AIR ECONOMIZERS. THERMOSTAT (KMC CONTROLS FLEX STAT MODEL BAC-130163C) SHALL MODULATE OUTDOOR AIR DAMPER AND RETURN AIR DAMPER TO PROVIDE "FREE COOLING" WHEN OUTDOOR AIR TEMPERATURE IS LOWER THAN THE INDOOR ROOM TEMPERATURE. THE RELIEF AIR MOTORIZED DAMPER SHALL OPEN WHEN HEAT PUMP IS IN "FREE COOLING" MODE. 2. REFER TO VENTILATION CALCULATION TABLE FOR MINIMUM OUTDOOR AIR CALCULATION. 3. THE FOLLOWING SYSTEMS SERVING GROUP R OCCUPANCIES DO NOT HAVE ECONOMIZERS IN ACCORDANCE WITH 2015 WASHINGTON STATE ENERGY CODE SECTION C403.3 EXCEPTION 6, NAMELY SEER RATING TO BE 15% HIGHER THAN MINIMUM, TABLE C403.2.3(2) FOR HEAT PUMPS; SPLIT SYSTEM < 65,000 BTU/FIR IS 14.0 SEER. 15% HIGHER IS 16.1 SEER, .1 OHP-1/IHP-1 IS 21.7 SEER > 16 SEER. 19,200 BTU/HR < 65,000 BTU/HR .2 OHP-2/IHP-2 IS 21.7 SEER > 16 SEER. 19,200 BTU/HR < 65,000 BTU/HR 4. THE FOLLOWING SYSTEMS SERVING DEDICATED OUTDOOR AIR SYSTEMS (DOHS) DO NOT HAVE ECONOMIZERS IN ACCORDANCE WITH 2O15 WASHINGTON STATE ENERGY CODE SECTION C403.3 EXCEPTION 1. .1 FC-1/HP-1, OHP-3/IHP-3 AND OHP-7/IHP-7 ARE SERVED BY HEAT RECOVERY VENTILATOR HRV-1. .2 OHP-4/IHP-4 IS SERVED BY SUPPLY FROM MUA-R-2, AND EXHAUST FROM EF-R-2. .3 OHP-8/IHP-8 AND OHP-9/IHP-9 IS SERVED BY SUPPLY FROM SF-1-1 AND EXHAUST FROM EF-1-2. 5. THE FOLLOWING SYSTEMS SERVING ELECTRONIC EQUIPMENT ROOMS DO NOT HAVE ECONOMIZERS IN ACCORDANCE WITH 2015 WASHINGTON STATE ENERGY CODE SECTION C403.3 EXCEPTION 10, NAMELY SEER RATING TO BE 15% HIGHER THAN MINIMUM. TABLE C403.2.3(2) FOR HEAT PUMPS; SPUT SYSTEM < 65,000 BTU/HR IS 14.0 SEER. 15% HIGHER IS 16.1 SEER. 1 OHP-5/IHP-5 IS 20.5 SEER > 1E1 SEER. 18,200 BTU/HR < 65,000 BTU/HR .2 OHP-6/IHP-6 IS 20.5 SEER > 16.1 SEER. 18,200 BTU/HR < 65,000 BTU/HR VENTILATION CALCULATIONS VENTILATION CALCULATION (AMENITY - COMMON AREAS) ROOM NAMEAREA# ` (SQ'FT) OF PEOPLE PEOPLE OUTDOOR AIR CFMIPERSON AREA OM CFMlSQ FT COMBINED CFM TOTAL CFM @ 80% EFFECTIVENESS ACTUAL CFM LOBBY 102 1,122 5 5 0.06 92 115 150 BISTRO 103 1,578 20 7.5 0.18 434 543 600 GREAT ROOM 104 1,520 34 7.5 0.18 529 661 700 STAFF ROOM 109 162 4 5 0.06 30 37 50 WORK ROOM 122 133 2 5 0.06 18 22 50 MANAGER 111 224 2 5 0.06 23 29 50 ASSISTANT MANAGER 110 159 1 5 0.06 15 18 50 CONFERENCE ROOM 123 168 4 5 0.06 30 38 50 SALES OFFICE 124 160 1 5 0.06 15 18 50 READING 214 560 8 5 0.06 74 92 150 GAME ROOM 211 652 8 5 0.06 79 99 150 THEATRE 210 634 15 5 0.06 113 141 200 FITNESS 345 1,303 10 20 0.06 278 348 400 YOGA 344 521 12 20 0.06 271 339 400 DINING 342/KITCHEN 343/FLEX 341 1,460 32 7.5 0.18 503 629 650 SALON 340 286 4 7.5 0.06 47 59 100 SALON 340 286 EXHAUST AT 0.5 CFM/S.F. = 143 CFM 150 VENTILATION CALCULATION (APARTMENTS) AREA (SQ.FT) BEDROOMS VENTILATION (CFM) ACTUAL CFM B.1 (L2 Only) 577 1 45 60 C.1 (If2 Only) 872 2 55 60 A.1 A 356 ` 1 30 60 A.2 N 393 1 30 60 A.2 S 403 1 30 60 A.2 W 403 1 30 60 A.3 W 565 1 45 60 A.4 W 539 1 45 60 A.5 W 547 1 45 60 B.2+Bale E 554 1 45 60 B.2+Bale N 554 1 45 60 B.2+Bale S 554 1 45 60 B.3 S 574 1 45 60 B.4 N 511 1 45 60 C.2 NW 867 2 55 60 C.2 SW 867 2 55 60 C.3 SE 910 2 55 60 C.4 NE 976 2 55 60 C.5 E 821 2 55 60 C.6 E 772 2 55 60 SITE PLAN: SCALE: 1"=32'-0" ADDRESS: 415 BAKER BOULEVARD, TUKWILA, WA 98188 LEGAL DESCRIPTION: ANDOVER INDUSTRIAL PARK #2 POR NLY &ELY OF LN RIG. S 01-34-33 W 235 FT FR PT ON N LN TR 8 DIST 354.10 FT ELY FR NW COR SD TR TH S 88-25-27 E 224.93 FT TO E LN TR 9 API: 022310-0080 BAKER BLVD FILE COPY Permit No. Plan review epprcvel is subject to errors and omissions. Ar7ovZ/ of c:Tstruct=on documents does not authorize lat,, code or ordinance. Receipt c FiGki Copy and conditions is acknowledged: Ey: e !� Date: 40r,12s'" 4 t f SPECIAL INSPECTIONS: 1. SPECIAL INSPECTION TESTING OF THE SMOKE CONTROL SYSTEM WILL BE IN ACCORDANCE WITH ALLEN ENGINEERING'S SMOKE CONTROL REPORT (UNDER SEPARATE PERMIT) AND IBC SECTION 909. THE SMOKE CONTROL SYSTEM WILL BE COMMISSIONED (INSPECTED AND TESTED) IN ACCORDANCE WWTH IBC 909.3 AND 909.18 THROUGH 909.19, BASED ON CHAPTER 8 OF NFPA 92 AND ASHRAE GUIDELINE 1.5. 2. VIBRO ACOUSTICS IS THE SPECIAL INSPECTOR FOR THE ISOLATOR SYSTEMS. REFER TO GENERAL NOTE 19. GENERAL NOTES: 1. COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER 2015 WASHINGTON STATE BUILDING CODE, 2015 WASHINGTON STATE MECHANICAL CODE, 2015 WASHINGTON STATE ENERGY CODE, AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTION. 2. CONTRACTOR SHALL COORDINATE DIFFUSER LOCATIONS AND DUCT ROUTING CLEARANCES WITH THE STRUCTURAL, REFLECTED CEILING AND LIGHTING PLANS. 3. CONTRACTOR SHALL COORDINATE PLUMBING VENT STACKS WITH THE EQUIPMENT TO MAINTAIN A MINIMUM OF 10 FEET FROM THE OUTSIDE AIR INTAKES. 4. ALL AIR DISTRIBUTION OUTLETS SHALL HAVE VOLUME CONTROL DEVICES. 5. ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH -ROUND OR SQUARE WITH TURNING VANES. 6. ALL DUCT PENETRATIONS THROUGH RATED ENCLOSURES SHALL BE FIRE DAMPERED. 7. ALL GAS EQUIPMENT SHALL BE INSTALLED PER THEIR USTINGS, UPC AND LOCAL CODES. 8. ALL ROOF PENETRATIONS SHALL BE MINIMUM OF 5 FEET AWAY FROM THE AREA/OCCUPATION SEPARATION WALLS. ALL PIPE, DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. 9. ALL MECHANICAL HEATING AND VENTILATION EQUIPMENT SHALL CONFORM TO SMACNA, ASHRAE, ASCE 7-10, LOCAL AND STATE REGULATIONS FOR SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). REFER TO "ACOUSTIC REQUIREMENTS" ON DRAWING MO.0 FOR EQUIPMENT RESTRAINT. VIBRO ACOUSTICS SHALL SUBMIT SHOP DRAWINGS FOR ALL DEVICES AND PROVIDE CALCULATIONS, CERTIFIED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. AFTER INSTALLATION, VIBRO ACOUSTICS SHALL VISIT THE SITE TO VERIFY THAT THE VIBRATION ISOLATION SYSTEMS ARE INSTALLED AND OPERATING PROPERLY. VIBRO ACOUSTICS SHALL VERIFY THAT ISOLATORS ARE ADJUSTED, WITH SPRINGS PERPENDICULAR TO BASES OR HOUSING, ADJUSTMENT BOLTS ARE TIGHTENED UP ON EQUIPMENT MOUNTINGS, AND HANGERS ARE NOT COCKED. HANGERS SHALL BE INSTALLED AS CLOSE TO THE STRUCTURE AS POSSIBLE. VIBRO ACOUSTICS SHALL SUBMIT A SIGN -OFF LETTER, CERTIFIED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. 10. ALL EQUIPMENT AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE ACCESS DOORS. ALL ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. 11. ALL DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. SUPPLY AND RETURN DUCTWORK TO HAVE 1" (OR 2" AS NOTED) SOUNDLINING IN LOCATIONS NOTED ON THE DRAWINGS. ALL DUCT LINING TO MEET AND/OR EXCEED MOLD, HUMIDITY, EROSION RESISTANT, ETC. TO MEET SMC. 12. ALL EQUIPMENT SHALL BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP. 13. COORDINATE WITH THE STRUCTURAL ENGINEER AND GENERAL CONTRACTOR TO PROVIDE STRUCTURAL SUPPORT FOR ALL EQUIPMENT. 14.ALL METALLIC DUCTWORK SHALL BE CONSTRUCTED AS SPECIFIED IN THE SMACNA DUCT CONSTRUCTION STANDARD -METAL AND FLEXIBLE. 2015 WASHINGTON STATE ENERGY CODE NOTES: 1. HVAC EQUIPMENT SHALL MEET THE MINIMUM ENERGY EFFICIENCY RATINGS PER 2015 WSEC TABLES C403.2.3(1)A., C403.2.3(2), C403.2.3(3), C403.2.3(4). 2. PIPING INSULATION SHALL MEET THE REQUIREMENTS OF TABLE C403.2.9. 3. OUTDOOR HVAC DUCTWORK SHALL HAVE A WEATHER PROOF BARRIER AND INSULATED TO MINIMUM R-8. 4. OUTDOOR AIR DUCTS INSULATED TO R-7. 5. SUPPLY AND RETURN DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO MINIMUM R-6. SUPPLY AND RETURN DUCTS IN CONDITIONED SPACES SHALL BE INSULATED TO MINIMUM R-3.3. 6. DUCTS, SHAFTS AND PLENUMS CONVEYING OUTSIDE AIR FROM THE EXTERIOR OF THE BUILDING TO THE MECHANICAL SYSTEM SHALL BE SEALED PER 2015 WSEC C403.2.8 AND C402.5. 7. AIR SYSTEMS SHALL BE BALANCED PER 2015 WSEC C408.2.2.1. 8. SYSTEMS COMMISSIONING SHALL BE PERFORMED PER 2015 WSEC C408 BY THE MECHANICAL CONTRACTOR. 9. FUNCTIONAL PERFORMANCE TESTING SHALL BE PERFORMED PER 2015 WSEC C408.2.3. 10. 2015 WSEC C103.6: PROJECT CLOSE OUT DOCUMENTATION AND TRAINING OF BUILDING OPERATIONS PERSONNEL IS REQUIRED FOR ALL MECHANICAL COMPONENTS, EQUIPMENT AND SYSTEMS GOVERNED BY THIS CODE. CLOSE OUT DOCUMENTATION SHALL INCLUDE: RECORD DOCUMENTS, DMA MANUALS, APPLICABLE WSEC COMPLIANCE FORMS AND CALCULATIONS City of Tukwila BUILDING DIVISION 0 FOR: L� ":,ehBniGa1 C-' 'Uclrical 1 1 mbing (1O CAS Piping I Tukwila DIVISION DRAWING LIST MO.0 COVER PAGE - MECHANICAL MO.1 MECHANICAL EQUIPMENT SCHEDULES MO.2 MECHANICAL EQUIPMENT SCHEDULES MO.3 SMOKE CONTROL MATRICES M1.1 LEVEL 1 - MECHANICAL M1.2 LEVEL 2 - MECHANICAL M1.3 LEVEL 3 - MECHANICAL M1.4 LEVEL 4 - MECHANICAL M1.5 LEVEL 5 - MECHANICAL M1.6 LEVEL 6 - MECHANICAL M1.7 LEVEL 7 - MECHANICAL M1.8 ROOF PLAN - MECHANICAL M2.1 NORTH ELEVATION M2.2 EAST ELEVATION M2.3 SOUTH ELEVATION M2.4 WEST ELEVATION M2.5 COURTYARD ELEVATIONS M3.1 MECHANICAL DETAILS :tiara / plan APPLICABLE CODES 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 WASHINGTON STATE ENERGY CODE LEGEND EQUIPMENT IDENTIFIER GRILLE IDENTIFIER - - - THERMOSTAT WIRING 24x12 ' DUCTWORK. SIZE IS INTERNAL SIZE. {24x12 1>x8 TAKEOFF SUPPLY DUCT UP SUPPLY DUCT DOWN RETURN DUCT UP 0 RETURN DUCT DOWN FA FB TA TB DN S.F. CFM A.P. EXHAUST DUCT UP EXHAUST DUCT DOWN ROUND DUCT UP ROUND DUCT DOWN BALANCE DAMPER FIRE DAMPER FIRE/SMOKE DAMPER PERM) I MOTORIZED DAMPER - CLASS 1 COUNTER -WEIGHTED BACKDRAFT DAMPER ACOUSTICALLY LINED DUCTWORK (SIZE USTED IS CLEAR INTERIOR DIMENSIONS) THERMALLY LINED DUCTWORK (SIZE USTED IS CLEAR INTERIOR DIMENSIONS) FIRE RATED DUCT WRAP CITYO THERMOSTAT CARBON MONOXIDE SENSOR & NITROGEN DIOXIDE SENSOR (GARAGE) FROM ABOVE FROM BELOW TO ABOVE TO BELOW DOWN SQUARE FEET CUBIC FEET PER MINUTE ROUND DUCT INDICATOR ACCESS PANEL OCEAN PARK MECHANICAL 149001NTER URBAN AVE. TELEPHONE 2066744553 LE WA 981. FACSIMILE 20.744564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE MECHANICAL COVER PAGE DATE APRIL 2018 DRAWN BY DL SCALE NOT TO SCALE MECHANICAL/ELECTRICAL MOTOR LIST UNIT # UNIT DESCRIPTION MANUFACTURER MODEL WEIGHT CAPACITY SOUND LEVEL SONES (LwA) UNIT LOCATION ELECTRICAL STARTER DISCONNECT NOTES BHP H.P. /W MCA/MAX FUSE VOLTS PH S I W S I W MAKE-UP AIR UNITS MUA-R-1 CORRIDOR MAKE-UP AIR UNIT (NORTH) STERLING PV25A2B01J63P2AB5 1,025 lb 250,000 BTUH INPUT 200,000 BTUH OUTPUT (80%) 4,000 CFM @ 0.75" SP 5 TON DX COOLING COIL (SHIPPED LOOSE FOR FIELD INSTALLATION) 78 LwA ROOF 2.75 BHP 3 HP 208 3 M E E E E E REFER TO NOTE 2. MUA-R-2 CORRIDOR MAKE-UP AIR UNIT (SOUTH) STERLING PV25A2B01J63P2AB5 1,025 lb 250,000 BTUH INPUT 200,000 BTUH OUTPUT (80%) 3,850 CFM @ 0.5" SP 5 TON DX COOLING COIL (SHIPPED LOOSE FOR FIELD INSTALLATIONj 75 LwA ROOF 2.31 BHP 3 HP 208 3 M E E E E E REFER TO NOTE 2. CONDENSING UNITS CU-R-1 CONDENSING UNIT FOR MUA-R-1 (NORTH) CARRIER 24ABB360-52 215 lb 5 TON COOLING CAPACITY EFFCIENCY: 13 SEER 79 dBA ROOF 21.4 MCA / 30 MOCP 208 3 E E E REFER TO NOTE 3. CU-R-2 CONDENSING UNIT FOR MUA-R-2 (SOUTh) CARRIER 24ABB360-52 215 lb 5 TON COOLING CAPACITY EFFICIENCY: 13 SEER 79 dBA ROOF 21.4 MCA / 30 MOCP 208 3 E E E REFER TO NOTE 3. HEAT RECOVERY VENTILATOR HRV-1 LEVEL 1 OFFICE SUPPLY / LEVEL 1 TOILET ROOM EXHAUST NV -AIR NU500 400 CFM @ 0.5" SP 66% THERMAL EFFICIENCY WORK ROOM 122 500 W 120 1 E E E CONTINUOUS OPERATION. FANS SPF-R-1 SPF-R-2 STAIR A PRESSURIZATION STAIR B PRESSURIZATION PENNBARRY PENNBARRY BHM30B REX27B 242 lb 325 lb 4,000 CFM @ 0.5" SP 4,000 CFM @ 0.5" SP STAIR A ROOF 1.51 BHP 0.74 BHP 2 HP VFD 1 HP VFD 208 208 3 3 M M H E E E E E E E E E REFER TO NOTE 4. REFER TO NOTE 4. INTAKE HOOD BY MECHANICAL. SPF-R-3 STAIR C PRESSURIZATION PENNBARRY BHM35B _ 242 lb 4,000 CFM @ 0.5" SP STAIRS 1.51 BHP 2 HP VFD 208 3 M E E E E E REFER TO NOTE 4. EPF-R-1 ELEVATOR 1 PRESSURIZATION PENNBARRY REX27B 325 lb 12,500 CFM @ 0.5" SP ROOF 5.67 BHP 7-1/2 HP VFD 208 M E E E E E REFER TO NOTE 4. INTAKE HOOD BY MECHANICAL. EPF-R-2 ELEVATOR 2 PRESSURIZATION PENNBARRY REX27B 325 lb 7,000 CFM @ 0.5" SP ROOF 1.65 BHP 2 HP VFD 208 3 M E E E E E REFER TO NOTE 4. INTAKE HOOD BY MECHANICAL. SEF-R-1 SMOKE EXHAUST FAN PENNBARRY D16 194 lb 4,000 CFM @ 1.0" SP ROOF 1.97 BHP 2 HP VFD 208 3 M E IS E E E REFER TO NOTE 5. SEF-R-2 SMOKE EXHAUST FAN PENNBARRY 016 194 lb 4,000 CFM @ 1.0" SP ROOF 1.97 BHP 2 HP VFD 208 3 M E IS E E E REFER TO NOTE 5. SEF-R-3 SMOKE EXHAUST FAN PENNBARRY 015 176 lb _3,000 CFM @ 1.0"SP ROOF 1.18 BHP 1-112 HP VFD 208 3 M IS IS E E E REFER TO NOTE 5. GEF-1-1 TO 1-3 GEF-2-1 TO 2-3 GARAGE EXHAUST FANS - LEVEL 1 GARAGE EXHAUST FANS - LEVEL 2 PENNBARRY PENNBARRY BHM30B BHM42B 242 lb 363 lb 6,000 CFM @ 0.375" SP 12,800 CFM @ 0.375" SP _ 14.4 (77 LwA) 19.8 (83 LwA) GARAGE LEVEL 1 GARAGE LEVEL 2 0.99 BHP 2.29 BHP 1-1/2 HP VFD 3 HP VFD 208 208 3 3 M M E E IS E E E E E E E REFER TO NOTE 6. REFER TO NOTE 6. GTF-1-1 TO 1-7 GARAGE TRANSFER FANS -LEVEL 1 CANARM LF18HVW 26 lb 3,200 CFM GARAGE LEVEL 1 1/8 HP (SEE NOTE 12) 120 1 E E E E E E REFER TO NOTE 7. GTF-1-8 GARAGE TRANSFER FAN - LEVEL 1 PENNBARRY BX20Q-E 35 lb 2,500 CFM @ 0.25" SP 14.8 (75 LwA) GARAGE LEVEL 1 0.31 BHP 1/3 HP VFD 208 3 E E E E E E REFER TO NOTE 6. GTF-2-1 TO 2-6 GARAGE TRANSFER FANS - LEVEL 2 CANARM LF18HVIN 26 lb _3,200 CFM _ GARAGE LEVEL 2 _ 1/8 HP (SEE NOTE 121 120 _ 1 E E E E E E REFER TO NOTE 7. DDC PANEL DDC PANEL FOR GARAGE VENTILATION SYSTEM SPRINKLER CONT. ROOM 112 20 AMP BREAKER 120 1 i E E E SINGLE 20 AMP 120V BREAKER FOR GARAGE VENTILATION DDC PANELS. SF-1-1 CATERING KITCHEN 120 SUPPLY FAN PENNBARRY SX115VCGP 70 lb 650 CFM @ 0.5" SP 5.1 SONES CATERING KITCHEN 120 0.14 BHP 1/2 HP (NOTE 12) 120 1 IS E E INTERLOCK TO EXHAUST FAN EF-1-2 BY ELECTRICAL CONTRACTOR. CNV MOTORIZED DAMPER. EF-1-1 JANITORS CLOSET EXHAUST FAN STERLING SEBOT 10 lb 70 CFM @ 0.25" SP 0.3 SONES @ 0.1" JANITOR'S CLOSET 25 W _ 120 1 E E E WIRED TO ON/OFF SVVFTCH BY ELECTRICAL CONTRACTOR. EF-1-2 CATERING KITCHEN 120 EXHAUST FAN PENNBARRY SX115VCGP 70 lb 650 CFM @ 0.5" SP 5.1 SONES GARAGE LEVEL 1 0.14 BHP 1/2 HP (NOTE 12) 120 1 E E E WIRED TO ON/OFF SWITCH BY ELECTRICAL CONTRACTOR. CNV MOTORIZED DAMPER. EF-2-1 TOILET ROOM 219 EXHAUST FAN STERLING 5E120 10 lb 80 CFM @ 0.4" SP 0.9 SONES @ 0.1" TOILET ROOM 219 39 W 120 1 E E E FAN WITH BUILT-IN MOTION SENSOR. CONTINUOUS ON LOW SPEED. HIGH SPEED UPON MOTION DETECTION. REFER TO NOTE 8. EF-2-2 HOUSEKEEPING CLOSET 218 EXHAUST FAN STERLING SEBOT . lb 70 CFM @ 0.25" SP 0.3 SONES @ 0.1" HOUSEKEEPING CLOSET 218 25 W 120 1 E E E CONTINUOUS OPERATION. WIRED BY ELECTRICAL CONTRACTOR REFER TO NOTE 8. EF-2-3 TRASH ROOM 216 EXHAUST FAN STERLING SEBOT 10 lb 70 CFM @ 0.25" SP 0.3 SONES @ 0.1" TRASH ROOM 216 25 W 120 1 E IS E CONTINUOUS OPERATION. WIRED BY ELECTRICAL CONTRACTOR. REFER TO NOTE 8. EF-3-1 TOILET ROOM 3416 EXHAUST FAN STERLING SEBOT 10 lb 70 CFM @ 0.25" SP 0.3 SONES @ 0.1" TOILET ROOM 314b 25 W 120 1 E E E FAN WITH BUILT-IN MOTION SENSOR CONTINUOUS ON LOW SPEED. HIGH SPEED UPON MOTION DETECTION. REFER TO NOTE 8. EF-3-2 SHOWER ROOM 349 EXHAUST FAN STERLING SEBOT 10 lb 70 CFM @ 0.25" SP 0.3 SONES @ 0.1" SHOWER ROOM 349 25 W 120 1 E E E FAN WITH BUILT-IN MOTION SENSOR. CONTINUOUS ON LOW SPEED. HIGH SPEED UPON MOTION DETECTION. REFER TO NOTE 8. EF-R-1 TRASH CHUTE EXHAUST FAN PENNBARRY DX11B 55 lb 1,000 CFM @ 0.5" SP 6.9 (65 LwA) ROOF 0.24 BHP 1/4 HP (NOTE 12) 120 1 IS E E CONTINUOUS OPERATION. WIRED BY ELECTFRICAL CONTRACTOR. REFER TO NOTE 8. EF-R-2 TRASH ROOM (LEVELS 3 TO 7) & SALON 340 EXHAUST FAN PENNBARRY DX08B 35 lb 650 CFM @ 0.5" SP 7.9 (67 LwA) ROOF 0.23 BHP 1(4 HP (NOTE 12) 120 1 E E E CONTINUOUS OPERATION. WIRED BY ELECTRICAL CONTRACTOR. RISERTO NOTES 8 AND 10. EF-R-3 DINING 308 / CHEF'S KITCHEN LOUNGE 306 EXHAUST FAN PENNBARRY DX08B 35 lb 650 CFM @ 0.5" SP 7.9 (67 LwA) ROOF 0.23 BHP 1/4 HP (NOTE 12) 120 1 E E WIRED TO THERMOSTAT. FAN OPERATES DURING OCCUPIED PERIODS. CAN MOTORZED DAMPER. EF-R-4 MEN'S 348 / WOMEN'S 347 EXHAUST FAN PENNBARRY DX08B 35 lb _500 CFM @ 0.5" SP 6.3 (64 LwA) ROOF 0.17 BHP 1/4 HP (NOTE 12) 120 1 E E E CONTINUOUS OPERATION. WIRED BY ELECTRICAL CONTRACTOR. REFER TO NOTE 8. EF-1 APARTMENT BATHROOM (IF DRYER IS IN MAIN BATHROOM) OR LAUNDRY ROOM (IF DRYER IS NOT IN MAIN BATHROOM) EXHAUST FAN PANASONIC FV-0510VS 1 60 CFM @ 0.25" SP HVI SONES @ 0.1" SP = 0.8 APARTMENT BATHROOM (IF DRYER IS IN MAIN BATHROOM) OR LAUNDRY ROOM (IF DRYER IS NOT IN MAIN BATHROOM) EXHAUST FAN 11.5 W (7.2 CFM/W) 120 1 E E E CONTINUOUS OPERATION FOR APARTMENT VENTILATION. REFER TO NOTE 9. EF-2 APARTMENT ENSUITE OR SUITE WASHROOM (IF DRYER IS NOT IN MAIN W/R) EXHAUST FAN PANASONIC FV-0510VS1 60 CFM @ 0.25" SP HVI SONES @ 0.1" SP = 0.8 APARTMENT ENSUITE OR SUITE WASHROOM (IF DRYER IS NOT IN MA/NW/RI EXHAUST FAN 11.5 W (7.2 CFM/X) 120 1 E E E WIRED TO ON/OFF SVVETCH. REFER TO NOTE 9. TF-1 INTERIOR BEDROOM TRANSFER FAN PENNBARRY TF8 130 CFM @ 0.2" SP HVI SONES @ 0.1" SP = 0.8 APARTMENT INTERIOR BEDROOMS 60 W 120 1 WITH BUILT-IN VARIABLE SPEED CONTROLLER. ELECTRIC DUCT HEATER EDH-1-1 CATERING KITCHEN 120 ELECTRIC DUCT HEA,TER THERMOLEC RAPIDEL SCR 12x12", 650 CFM 24 °F OUTDOOR AIR 65 °F SUPPLYAIR CATERING KITCHEN 120 9,000 W 208 3 E IS E WIRED TO DUCT STAT WITH SCR CONTROL BY ELECTRICAL. WIRED TO AIR PROVING SWITCH. _ DOMESTIC HOT WATER BOILERS B-1 & 2 DOMESTIC HOT WATER BOILERS LOCHINVAR ARMOR AWN700PM 461 lb 700,000 BTUH INPUT 815 GPH @ 100 °F TEMP RISE 96% EFFICIENT ROOF BOILER ROOM 16 MCA 120 1 E E E T & P RELIEF VALVE. DRAIN VALVE. AQUASTAT IN STORAGE TANK ST-1 WIRING BETWEEN MASTER BOILER B-1 AND MEMBER BOILER B-2. REFER TO NOTE 11. NOTES: 1. SEE DRAWINGS FOR LOCATIONS OF MOTORIZED DAMPERS AND FIRE SMOKE DAMPERS 2. HORIZONTAL DISCHARGE. STAINLESS STEEL HEAT EXCHANGER. 4 TO 1 ELECTRONIC DISCHARGE AIR CONTROL. MODULATING COMBUSTION CONTROL WITH MOTORIZED INLET DAMPER. AUTOMATICALLY CLOSED WHEN SYSTEM IS NOT IN USE. OUTDOOR UNITWITH INLET HOOD. SMOKE DETECTOR ON DISCHARGE OF UNIT -TO SHUT DOWN UNITWHEN SMOKE IS DETECTED. SMOKE DETECTOR SUPPLIED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 3. REFRIGERANT PIPING TO MUA UNIT BY MECH. CONTRACTOR. WIRED TO THERMOSTAT ON LEVEL 4 BY MECH. CONTRACTOR. LOCK OUT HEATING WHEN IN COOLING MODE. 2015 WSEC TABLE C403.2.3(1)A - MINIMUM EFFICIENCY FOR SPLIT SYSTEM, AIR CONDITIONERS, AIR COOLED <65,000 BTU/HOUR IS 13.0 SEER 4. WIRED TO FIRE ALARM PANEL BY ELECTRICAL CONTRACTOR. WIRED TO MOTORIMD DAMPER (FAIL OPEN). PRESSURIZATION SHALL BE ACTIVATED BY A FIRE ALARM ORIGINATING ANYWHERE IN THE BUILDING. TWO SMOKE DETECTORS SHALL BE LOCATED IN THE DUCT IN ACCORDANCE WITH NFPA 76 ARRANGED TO AUTOMATICALLY SHUT DOWN THE FAN SYSTEM ONLYWHEN BOTH SMOKE DETECTORS ACTIVATED. THE DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM AS A SUPERVISORY SIGNAL. A LEGALLY REQUIRED STANDBY POWER SYSTEM SHALL BE PROVIDED FOR THE PRESSURIZATION FAN. MOTORIZED DAMPER SHALL OPEN (END SWITCH ON MOTORIZED DAMPER WIRED TO FIRE COMMAND CENTER TO DISPLAY STATUS) FAN VFD INTERNAL CURRENT SENSORS (FAN ON & FAN OFF) CONNECTED TO FIRE ALARM SYSTEM FOR INDICATION ON FIREFIGHTER SMOKE CONTROL PANEL (FSCP). ALL WRING AND INTERLOCK BY DIVISION 16. PROVIDE 1.5 TIMES . OF BELTS REQUIRED FOR DESIGN DUTYWITH MINIMUM OF 2. 5. THE SMOKE EXHAUST FAN OPERATES PER SEQUENCE SPECIFIED IN SMOKE CONTROL MATRIX - MECHANICAL EQUIPMENT g, SMOKE CONTROL MATRIX - SMOKE EXHAUST . PROVIDE 1.5 TIMES . OF BELTS REQUIRED FOR DESIGN DUTYWITH MINIMUM OF 2. 6. REFER TO GARAGE VENTILATION MATRIX FOR CONTROL SEQUENCE. ALL WIRING TO CO AND NO2 SENSORS AND FAN INTERLOCKS BY CONTROLS CONTRACTOR. FINAL SETUP OF VFD'S BY CONTROLS CONTRACTOR. CM/MOTOR SIDE GUARD. SUSPENDED FROM CEILING WITH SEISIMIC SPRING ISOLATORS. DUCTING TO BE ATTACHED W. NEOPRENE OR CANVAS FLEXIBLE CONNECTOR. 7. REFER TO GARAGE VENTILATION MATRIX FOR CONTROL SEQUENCE. CONTROL WIRING TO CO AND NO2 SENSOR BY CONTROLS CONTRACTOR. 8. 2015 WASHINGTON STATE ENERGY CODE C403.2.4.3. MOTORIZED DAMPER IS NOT REQUIRED FOR SYSTEMS SERVING AREAS WHICH REQUIRE CONTINUOUS OPERATION. 9. 2015 WASHINGTON STATE ENERGY CODE C403.2.4.3. GRAVITY (NON MOTOREED) DAMPER IN GROUP R OCCUPANCY WFIERE AIRFLOW IS LESS THAN 400 CFM. 10. 2015 WASHINGTON STATE BUILDING CODE 717.5.3. EXCEPTION 2. 2.3. EXHAUST FAN EF-R-2 TO BE PROVIDED WITH A LEGALLY REQUIRED STANDBYPOWER SYSTEM IN ACCORDANCE WITH SECTION 909.11 TO MAINTAIN A CONTINUOUS UPWARD AIRFLOW TO THE OUTSIDE. 11. ELECTRICAL CONTRACTOR TO PROVIDE ON/OFF SWITCH AT DOOR OUTSIDE MECHANICAL ROOM TO SHUT OFF BOILERS IN BOILER ROOM. 12. MOTOR SHALL HAVE MINIMUM EFFICIENCY OF 70% PER 2015 WSEC C405.8 END OF SCHEDULE GARAGE VENTILATION MATRIX EXHAUST FANS TRANSFER FANS FAN # GEF-1-1 TO 3 (VFD) GEF-2-1 TO 3 (VFD) GTE-1-1 GTE-1-2 GTF-1-3 GTF-1-4 GTE-1-5 GTF-1-6 GTE-1-7 GTE-1-8 GTF-2-1 GTE-2-2 GTF-2-3 GTF-2-4 GTF-2-S GTF-2-6 LEVEL I 2 1 1 1 1 1 1 1 1 2 2 2 2 2 2 CONTINUOUS ON LOIN SPEED YES YES NO NO NO NO NO NO NO YES NO NO NO NO NO NO CO / NO2 TAG # 1-1 X X X 1-2 X X X X 1-3 X X X 1-4 X X X 1-5 X X X X 1-6 X X X 2-1 X X X 2-2 X X 2-3 X X 2-4 X X 2-5 X 2-6 X X CONTROL SEQUENCE: CONTROLS CONTRACTOR SHALL PROVIDE CONDUIT FROM CO AND NO2 SENSORS AND FANS TO DDC PANEL IN MAINTENANCE 107. SYSTEM ENABLED 24/7. EXHAUST FANS AND 'TRANSFER FAN OPERATE AT MINIMUM SPEED TO MEET CODE MINIMUM OF 0.05 CEO/SQUARE FOOT. CO TRANSMITTERS (5.-0" AFF) MONITOR ZONE CO LEVELS, WHENCO LEVEL IS BETWEEN 15 PPM AND 35 PPM, FAN VFDs RAMP LINEARLY FROM MINIMUM (15 HZ - ADJUSTABLE) TO MAXIMUM SPEED (DO HZ - ADJUSTABLE), NO2 TRANSMITTERS (1'.6" AFF) MONITOR ZONE NO2 LEVELS, WHEN NO2 LEVEL IS BETWEEN 1 PPM AND 3 PPM, FAN VFDs RAMP LINEARLY FROM MINIMUM (15 HZ - ADJUSTABLE) TO MAXIMUM SPEED (60 HZ - ADJUSTABLE). END OF MATRIX BAC5901C DDC PANEL IN SPRINKLER ROOM 112 2 NOTES: 1. 20 AMP, 120 VOLT POWER BY ELECTRICAL CONTRACTOR FOR WE DDC CONTROL PANEL LOCATED IN SPRINKLER CONT. ROOM 112. 2. TN CONDUIT BY THE CONTROLS CONTRACTOR. 3. CONTROL WIRING AND DC POWER BY THE CONTROLS CONTRACTOR. 4. BACNET DEVICES TO BE DAISY CHAINED. 5. TRANSFER FANS TO BE WIRED TO END SWITCH ON GAS SENSOR. 6. CONDUIT BETWEEN SENSORS TO BE IN THE SLAB. 7. CONDUIT BETWEEN FLOORS TO BE SURFACE MOUNTED. 8. CARBON MONOXIDE SENSOR TO BE DEL MODEL A/B5-0O3 BACNET DEVICE. 9. NITROGREN DIOXIDE SENSOR TO BE GEL MODEL A/B5-NO2, BACNET DEVICE. GARAGE VENTILATION - WIRING DIAGRAM END OF LINE FOR CONTROLS CIRCUIT -4 EDCNON TIORCIF UNE RCUIT GRILLE, DIFFUSER & LOUVER SCHEDULE: L-1 4" DEEP ORB/NOBLE BLADE LOUVER S-1 DOUBLE DEFLECTION SUPPLY AIR GRILLE WITH BACKDRAFT DAMPER, FRONT BLADE IS HORIZONTAL 1/2" BLADE SPACING. S-2 SQUARE PLAQUE SUPPLY AIR DIFFUSER, 24"x24", NECK SIZE ON DRAWINGS. R-1 SINGLE DEFLECTION RETURN AIR GRILLE E-1 SINGLE DEFLECTION EXHAUST AIR GRILLE DG-1 DOOR GRILLE RECEIVED CITY OF T IJ K L A PERMiT CENTER 2 C M] OCEAN PARK MECHANICAL 4283, 14300 INTER URBAN AVE. TELEPHONE 2.6744553 SEATTLE. WA BB168 FACSIMILE 2.6744564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH, PERMIT 04/20/2018 REISSUED FOR MECH, PERMIT DRAWING TITLE MECHANICAL EQUIPMENT SCHEDULES DATE APRIL 2018 DRAWN BY DL SCALE NOT TO SCALE MO.1 NOTE: CONFIRM COLOR WITH ARCHITECT. TAG VTHP-1 VTHP-2 VTHP-3 MAKE GE GE GE MODEL AZ91H09D2C AZ91H12D3C AZ91 H18D3C VERTICAL TERMINAL HEAT PUMPS (VTHP) SCHEDULE CFM 420 420 450 COOLING HEATING (HEAT PUMP) ELECTRIC HEATER ELECTRICAL CAPACITY (BTU/H) 9,400 12,000 18,000 EER (AHRI) 10.4 10.0 10.0 CAPACITY (BTU/H) 8,400 10,900 16,400 COP (AH RI) 3.0 3.0 3.0 CAPACITY (W) 2,050 2,780 2,780 MCA AMPS 15 20 20 MAX FUSE 15 20 20 VOLTS 208 208 208 PHASE WEIGHT (LB) 114 125 168 NOTES SEE NOTES 1, 2 AND 5. SEE NOTES 1, 3AND 5. SEE NOTES 1, 4 AND 5. NOTES: 1. ARCHITECTURAL LOUVER. PLENUM BETWEEN LOUVER AND UNIT. ACCESS PANEL WITH RETURN AIR GRILLE. PROGRAMMABLE WALL THERMOSTAT (10 °F DEADBAND). 2. LOCATED IN UNIT A.1, A.2, A.3, A.4, A.5. 3. LOCATED IN UNIT 6.2, B.3, 6.4, C.5, C.6. 4. LOCATED IN UNIT C.2, C.3, C.4. 5. 2015 WSEC TABLE C403.2,3(3) - MINIMUM EFFICIENCY FOR SINGLE PACKAGE VERTICAL HEAT PUMPS (SPVHP) < 65,000 BTU/HOUR IS 10.0 EER COOLING & 3.0 COP HEATING. END OF SCHEDULE COOLING UNITS MOTOR LIST ELECTRICAL DISCONNECT UNIT # UNIT DESCRIPTION MANUFACTURER MODEL WEIGHT CAPACITY SOUND LEVEL (LwA) UNIT LOCATION NOTES H.P. / W MCA/MAX FUSE VOLTS PH S I W FAN COIL UNITS FC-1 MAN FLOOR OFFICES CARRIER FB4CNP024 112 lb 2 TONS COOLING CAPACITY 800 CFM @ 0.5" SP CLOSET IN STAFF ROOM 109 1/3 HP FAN MOTOR 6 kW ELECTRIC HEAT 44.7 MCA 45 MOCP 208 1 E E E REFER TO NOTE 1 & 8. FC-2 GREAT ROOM 104 CARRIER FB4CNP048 157 lb 4 TONS COOLING CAPACITY 1,600 CFM @ 0.5" SP GREAT ROOM 104 3/4 HP FAN MOTOR 13.5 kW ELECTRIC HEAT 55.5 MCA 60 MOCP 208 3 E E E REFER TO NOTE 1 & 8. FC-3 B BISTRO 103 / LOBBY 102 CARRIER FX4DNB061 L 201 lb 5 TONS COOLING CAPACITY 2,000 CFM @ 0.5" SP READING ROOM / LOUNGE 214 3/4 HP FAN MOTOR 13.5 kW ELECTRIC HEAT 55.5 MCA 60 MOCP 208 3 E E E REFER TO NOTE 1 & 8. THERMOSTAT WITH CO2 FOR DEMAND CONTROLLED VENTILATION. FC-4 READING ROOM / LOUNGE 214 CARRIER FB4CNP018 112 lb 1.5 TONS COOLING CAPACITY 600 CFM @ 0.5" SP READING ROOM / LOUNGE 214 1/3 HP FAN MOTOR 3.8 kW ELECTRIC HEAT 26 MCA 30 MOCP 208 1 E E E REFER TO NOTE 1 & 8. FC-5 GAME ROOM 211 CARRIER FB4CNP024 112 lb 2 TONS COOLING CAPACITY 800 CFM @ 0.5" SP MECH 212 1/3 HP FAN MOTOR 6 kW ELECTRIC HEAT 44.7 MCA 45 MOCP 208 1 E E E REFER TO NOTE 1 & 8. FC-6 THEATRE 210 CARRIER FB4CNP018 112 lb 1.5 TONS COOLING CAPACITY 600 CFM @ 0.5" SP MECH 212 1/3 HP FAN MOTOR 6 kW ELECTRIC HEAT 44.7 MCA 45 MOCP 208 1 E E E REFER TO NOTE 1 & 8. FC-7 FITNESS 345 CARRIER FB4CNP036 122 lb 3 TONS COOLING CAPACITY 1,200 CFM @ 0.5" SP FITNESS 345 1/2 HP FAN MOTOR 11.3 kW ELECTRIC HEAT 47.7 MCA 50 MOCP 208 3 E E E REFER TO NOTE 1 & 8. FC-8 YOGA 344 CARRIER FB4CNP018 112 lb 1.5 TONS COOLING CAPACITY 600 CFM @ 0.5" SP YOGA 344 1/3 HP FAN MOTOR 6 kW ELECTRIC HEAT 44.7 MCA 45 MOCP 208 1 E E E REFER TO NOTE 1 & 8. FC-9 DINING 342/KITCHEN 343/FLEX 341 CARRIER FB4CNP036 1221b 3 TONS COOLING CAPACITY 1,200 CFM @ 0.5" SP DINING 342 1/2 HP FAN MOTOR 11.3 kW ELECTRIC HEAT 47.7 MCA 50 MOCP 208 3 E E E REFER TO NOTE 1 & 8. HEAT PUMPS HP-1 MAIN FLOOR OFFICES CARRIER 25HHA424 161 lb CLG (23.4 MBH; 14 SEER) HTG (22.2 MBH @ 47°F) HTG (13.7 MBH @ 17°F) HTG EFFICIENCY 8.2 HSPF 69 dBA GARAGE LEVEL 1 16.5 MCA 25 MOCP 208 1 E E E REFER TO NOTE 2 & 7. HP-2 GREAT ROOM 104 CARRIER 25HHA448 246 lb CLG (45.5 MBH; 14 SEER) HTG (46.0 MBH @ 47°F) HTG (29.0 MOH © 17°F) HTG EFFICIENCY 8.2 HSPF 73 dBA GARAGE LEVEL 2 18.6 MCA 30 MOCP 208 3 E E E REFER TO NOTE 2 & 7. HP-3 BISTRO 103 / LOBBY 102 CARRIER 25HHA460 258 lb CLG (55.0 MBH; 14 SEER) HTG (55.0 MBH @ 47°F) HTG (33.6 MBH @ 17°F) HTG EFFICIENCY8.2 HSPF 74 dBA GARAGE LEVEL 2 22.9 MCA 40 MOCP 208 3 E E E REFER TO NOTE 2 & 7. HP-4 READING ROOM / LOUNGE 214 CARRIER 25HHA418 150 lb CLG (17.2 MBH; 14 SEER) HTG (16.8 MBH @ 47°F) HTG (10.3 MBH @ 17°F) HTG EFFICIENCY 8.2 HSPF 70 dBA GARAGE LEVEL 2 11.8 MCA 20 MOCP 208 1 E E E REFER TO NOTE 2 & 7. HP-5 GAME ROOM 211 CARRIER 25HHA424 161 lb CLG (23.4 MBH; 14 SEER) HTG (22.2 MBH @ 47°F) HTG (13.7 MBH @ 17°F) HTG EFFICIENCY 8.2 HSPF 69 dBA GARAGE LEVEL 2 16.5 MCA 25 MOCP 208 1 E E E REFER TO NOTE 2 & 7. HP-6 THEATRE 210 CARRIER 25HHA418 1501b CLG (17.2 MBH; 14 SEER) HTG (16.8 MBH @ 47°F) HTG (10.3 MBH @ 17°F) HTG EFFICIENCY8.2 HSPF 70 dBA GARAGE LEVEL 2 11.8 MCA 20 MOCP 208 1 E E E REFER TO NOTE 2 & 7. HP-7 FITNESS 345 CARRIER 25HHA436 197 lb CLG (32.8 MBH; 14 SEER) HTG (33.0 MBH @ 47°F) HTG (20.0 MBH @ 17°F) HTG EFFICIENCY8.2 HSPF 71 ABA GARAGE LEVEL 2 12.8 MCA 20 MOCP 208 3 E E E REFER TO NOTE 2 & 7. HP-8 YOGA 344 CARRIER 25HHA418 150 lb CLG (17.2 MBH; 14 SEER) HTG (16.8 MBH @ 47°F) HTG (10.3 MBH @ 17°F) HTG EFFICIENCY8.2 HSPF 70 dBA GARAGE LEVEL 2 11.8 MCA 20 MOCP 208 1 E E E REFER TO NOTE 2 & 7. HP-9 DINING 342/KITCHEN 343/FLEX 341 CARRIER 25HHA436 197 lb CLG (32.8 MBH; 14 SEER) HTG (33.0 MBH @ 47°F) HTG (20.0 MBH @ 17°F) HTG EFFICIENCY 8.2 HSPF 71 dBA GARAGE LEVEL 2 12.8 MCA 20 MOCP 208 3 E E E REFER TO NOTE 2 & 7. D DUCTLESS SPLIT SYSTEM HEAT PUMPS IHP-1-1, 1-2 SPLIT SYSTEM AC UNIT - UNIT 202 (INDOOR UNIT) LG LMN097HVT 23 Ibs UNIT 202 208 1 REFER TO NOTE 3 & 8. OHP-1 SPLIT SYSTEM AC UNIT - UNIT 202 (OUTDOOR UNIT) LG LMU247HV 130 lbs 2 TON COOLING CAPACITY REFRIGERANT- R-410A 21.7 SEER 9.4 HSPF COOLING 19.2 MBH HEATING 26.4 MBH GARAGE LEVEL 2 12.6 MCA 21.8 MOCP 208 1 E E E REFER TO NOTE 4 & 7. IHP-2-1, 2-2, 2-3 SPLIT SYSTEM AC UNIT - UNIT 201 (INDOOR UNIT) LG LMN097HVT 23 lbs UNIT 201 208 1 REFER TO NOTE 3 & 8. OHP-2 SPLIT SYSTEM AC UNIT - UNIT 201 (OUTDOOR UNIT) LG LMU247HV 130 Ibs 2 TON COOLING CAPACITY REFRIGERANT- R-410A 21.7 SEER 9.4 HSPF COOLING 19.2 MBH HEATING 26.4 MBH GARAGE LEVEL 2 12.6 MCA 21.8 MOCP 208 1 E E E REFER TO NOTE 4 & 7. IHP-3 SPLIT SYSTEM AC UNIT - STAFF ROOM 109 (INDOOR UNIT) LG LSNO9OHSV4 20 Ibs STAFF ROOM 109 208 1 REFER TO NOTE 3 & 8. OHP-3 IHP-4 SPLIT SYSTEM AC UNIT - STAFF ROOM 109 (OUTDOOR UNIT) SPLIT SYSTEM AC UNIT - SALON 340 (INDOOR UNIT) LG LG LSUO90HSV4 LSNO9OHSV4 75 Ibs 20 lbs 3/4 TON COOLING, REFRIGERANT - R-410A 21.5 SEER, 10.8 HSPF, COOLING 9 MBH, HEATING 10.8 MBH GARAGE LEVEL 1 SALON 340 10.0 MCA / 15 MOCP 208 208 1 1 E E E REFER TO NOTE 5 & 7. REFER TO NOTE 3 & 8. OHP-4 SPLIT SYSTEM AC UNIT - SALON 340 (OUTDOOR UNIT) LG LSU09OHSV4 75 Ibs 3/4 TON COOLING, REFRIGERANT - R-410A 21.5 SEER, 10.8 HSPF, COOLING 9 MBH, HEATING 10.8 MBH GARAGE LEVEL 3 10.0 MCA / 15 MOCP 208 1 E E E REFER TO NOTE 5 & 7. IHP-5 SPLIT SYSTEM AC UNIT- ELEVATOR MACHINE ROOM 801 (INDOOR UNIT) LG LSN180HSV4 31 lbs ELEVATOR MACHINE ROOM 801 208 1 REFER TO NOTE 3 & 8. OHP-5 SPLIT SYSTEM AC UNIT - ELEVATOR MACHINE ROOM 801 (OUTDOOR UNIT) LG LSU180HSV4 121 lbs 1.5 TON COOLING CAPACITY REFRIGERANT- R-410A 20.5 SEER 9.7 HSPF COOLING 18.2 MBH HEATING 22.0 MBH ROOF 19 MCA 25 MOCP 208 1 E E E REFER TO NOTE 6 & 7. IHP-6 SPLIT SYSTEM AC UNIT - ELEVATOR MACHINE ROOM 802 (INDOOR UNIT) LG LSN180HSV4 31 lbs ELEVATOR MACHINE ROOM 802 208 1 REFER TO NOTE 3 & 8. OHP-6 SPLIT SYSTEM AC UNIT - ELEVATOR MACHINE ROOM 802 (OUTDOOR UNIT) LG LSU180HSV4 121 lbs 1.5 TON COOLING CAPACITY REFRIGERANT - R-410A 20.5 SEER 9.7 HSPF COOLING 18.2 MBH HEATING 22.0 MBH ROOF 19 MCA 25 MOCP 208 1 E E E REFER TO NOTE 6 & 7. IHP-7 SPLIT SYSTEM AC UNIT - WORK ROOM 122 (INDOOR UNIT) LG LSNO9OHSV4 20 Ibs WORK ROOM 122 208 1 REFER TO NOTE 3 & 8. OHP-7 SPLIT SYSTEM AC UNIT - WORK ROOM 122 (OUTDOOR UNIT) LG LSUO90HSV4 75 lbs 3/4 TON COOLING, REFRIGERANT - R-410A 21.5 SEER, 10.8 HSPF, COOLING 9 MBH, HEATING 10.8 MBH GARAGE LEVEL 1 10.0 MCA / 15 MOCP 208 1 E E E REFER TO NOTE 5 & 7. HP-8 SPLIT SYSTEM AC UNIT - CATERING KITCHEN 120 (INDOOR UNIT) LG LSN180HSV4 31 lbs CATERING KITCHEN 120 208 1 REFER TO NOTE 3 & 8. OHP-8 SPLIT SYSTEM AC UNIT - CATERING KITCHEN 120 (OUTDOOR UNIT) LG LSU180HSV4 121 Es 1.5 TON COOLING CAPACITY REFRIGERANT - R-410A 20.5 SEER 9.7 HSPF COOLING 18.2 MBH HEATING 22.0 MBH GARAGE LEVEL 1 19 MCA 25 MOCP 208 1 E E E REFER TO NOTE 5 & 7. HP-9 SPLIT SYSTEM AC UNIT - CATERING KITCHEN 120 (INDOOR UNIT) LG LSN180HSV4 31 lbs CATERING KITCHEN 120 208 1 REFER TO NOTE 3 & 8. OHP-9 SPLIT SYSTEM AC UNIT - CATERING KITCHEN 120 (OUTDOOR UNIT) LG LSU180HSV4 121 Ibs 1.5 TON COOLING CAPACITY REFRIGERANT- R-410A 20.5 SEER 9.7 HSPF COOLING 18.2 MBH HEATING 22.0 MBH GARAGE LEVEL 1 19 MCA 25 MOCP 208 1 E E E REFER TO NOTE 5 & 7. NOTES: 1. 100, ECONOMIZER. LINE VOLTAGE WIRING BY ELECTRICAL CONTRACTOR. WIRING TO THERMOSTAT AND REFRIGERANT PIPING BY MECHANICAL CONTRACTOR. COMPRESSION HEATING IS FIRST STAGE OF HEAT AND CONTROLS SHALL BE PROVIDED TO PREVENT AUXILIARY HEAT OPERATION ABOVE 40°F. EQUIPPED WITH AN AUXILIARY AND SECONDARY DRAIN SYSTEM THAT IS REQUIRED PER 2015 IMC SECTION 307.2.3. 2. R-410A REFRIGERANT. WIRED BY ELECTRICAL CONTRACTOR. REFRIGERANT PIPING BETWEEN OUTDOOR UNIT AND INDOOR UNIT BY MECHANICAL CONTRACTOR. 3. WIRING FROM OUTDOOR UNIT TO INDOOR UNIT BY ELECTRICAL CONTRACTOR. 4. R-410A REFRIGERANT. WIRED BY ELECTRICAL CONTRACTOR. REFRIGERANT PIPING BETWEEN OUTDOOR UNIT AND INDOOR UNIT BY MECHANICAL CONTRACTOR. ECONOMIZERS NOT REQUIRED PER 2015 WSEC C403.3. ECONOMIZERS EXCEPTION 6. 5. R-410A REFRIGERANT. WIRED BY ELECTRICAL CONTRACTOR. REFRIGERANT PIPING BETWEEN OUTDOOR UNIT AND INDOOR UNIT BY MECHANICAL CONTRACTOR. ECONOMIZERS NOT REQUIRED PER 2015 WSEC C403.3. ECONOMIZERS EXCEPTION 1. 6. R-410A REFRIGERANT. WIRED BY ELECTRICAL CONTRACTOR. REFRIGERANT PIPING BETWEEN OUTDOOR UNIT AND INDOOR UNIT BY MECHANICAL CONTRACTOR. ECONOMIZERS NOT REQUIRED PER 2015 WSEC C403.3. ECONOMIZERS EXCEPTION 10. 7.2015 WSEC TABLE C403.2.3(2) - MINIMUM EFFICIENCY FOR SPLIT SYSTEM, HEAT PUMPS, AIR COOLED <65,000 BTU/HOUR IS 14.0 SEER. 8. THERMOSTAT SHALL HAVE MINIMUM 5 °F DEADBAND BETWEEN COOLING AND HEATING SETPOINTS. END OF SCHEDULE RECEIVED CITY OF TUKWILA HERMIT CENTF;H CPMD OCEAN PARK MECHANICAL M283,14900INTER URBAN AVE. TELEPHONE 206674-4553 SEATTLE. WA 98168 FACSIMILE 20.67.5. PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE MECHANICAL EQUIPMENT SCHEDULES DATE APRIL 2018 DRAWN BY DL SCALE NOT TO SCALE MO.2 SMOKE CONTROL MATRIX - MOTOR LIST UNITII UNIT DESCRIPTION MANUFACTURER MODEL WEIGHT CAPACITY UNIT LOCATION ELECTRICAL EMERGENCY POWER STARTER DISCONNECT NOTES BHP H.P. / W VOLTS PH S I W S I W SPF-R-1 STAIR A PRESSURIZATION PENNBARRY BHM30B 242 lb _4,000 CFM @ 0.5" SP STAIR A 1.51 BHP 2 HP VFD 208 3 YES M E E E E E REFER TO NOTE 1. SPF-R-2 STAIR B PRESSURIZATION PENNBARRY REX27B 325 lb 4,000 CFM @ 0.5" SP ROOF 0.74 BHP 1 HP VFD 208 3 YES M E E E E E REFER TO NOTE 1. SPF-R-3 STAIR C PRESSURIZATION PENNBARRY BHM30B 242 lb 4,000 CFM a,7, 0.5" SP STAIR B 1.51 BHP 2 HP VFD 208 3 YES M E E E E E REFER TO NOTE 1. EPF-R-1 ELEVATOR 1 PRESSURIZATION PENNBARRY REX27B 325 lb 12,500 CFM @ 0.5" SP ROOF 5.67 BHP 7-1/2 HP VFD' 208 3 YES M E E E E E REFER TO NOTE 1. EPF-R-2 ELEVATOR 2 PRESSURIZATION PENNBARRY REX27B 325 lb 7,000 CFM @ 0.5" SP ROOF 1.65 BHP 2 HP VFD 208 3 YES M E E E E E REFER TO NOTE 1. SEF-R-1 SMOKE EXHAUST FAN PENNBARRY 1)16 194 lb 4,000 CFM @ 1.0" SP ROOF 1.97 BHP _ 2 HP VFD 208 3 YES M E E E E E REFER TO NOTE 2. SEF-R-2 SMOKE EXHAUST FAN PENNBARRY D16 194 lb 4,000 CFM @ 1.0" SP ROOF 1.97 BHP 2 HP VFD 208 3 YES M E E E E E REFER TO NOTE 2. SEF-R-3 SMOKE EXHAUST FAN PENNBARRY D15 1761b 3,000 CFM @ 1.0" SP ROOF 1.18 BHP 1-1/2 HP VFD _ 208 3 YES _ M E E E E E REFER TO NOTE 2. NOTES 1 INTERLOCK WITH FIRE ALARM PANEL. PRESSURIZATION FAN TO OPERATE IN A BUILDING FIRE ALARM CONDITION UPON ACTIVATION OF ANY ALARM SIGNAL WITHIN THE BUILDING, EXCEPT FOR SINGLE STATION SMOKE ALARMS IN INDIVIDUAL GUESTROOMS. MOTORIZED DAMPER SHALL OPEN (END SWITCH ON MOTORIZED DAMPER WIRED TO FIRE COMMAND CENTER TO DISPLAY STATUS). FAN VFD INTERNAL CURRENT SENSORS (FAN ON & FAN OFF) CONNECTED TO FIRE ALARM SYSTEM FOR INDICATION ON FIREFIGHTER SMOKE CONTROL PANEL (FSCP). ALL WIRING AND INTERLOCK BY DIVISION 16. PROVIDE 1.5 TIMES # OF BELTS REQUIRED FOR DESIGN DUTY WITH MINIMUM OF 2. 2 THE SMOKE EXHAUST FAN OPERATES PER SEQUENCE SPECIFIED IN SMOKE CONTROL MATRIX - MECHANICAL EQUIPMENT & SMOKE CONTROL MATRIX - SMOKE EXHAUST DAMPERS . PROVIDE 1.5 TIMES # OF BELTS REQUIRED FOR DESIGN DUTY WITH MINIMUM OF 2. END OF MOTOR LIST SMOKE CONTROL MATRIX - MECHANICAL EQUIPMENT EQUIPMENT # UNIT DESCRIPTION LOCATION EMERGENCY POWER REQUIRED (Y/N) NORMAL OPERATION ALARM MODE (SEE NOTE 1) MONITORED FROM FIREFIGHTER SMOKE CONTROL PANEL (FSCP) (SEE NOTE 2) MANUAL CONTROL FROM FIREFIGHTER SMOKE CONTROL PANEL (FSCP) MAKE-UP AIR UNITS MUA-R-1 NORTH MAKE-UP AIR UNIT ROOF N SEE NOTE 3 SEE NOTE 3 YES NO MUA-R-2 SOUTH MAKE-UP AIR UNIT ROOF N SEE NOTE 3 SEE NOTE 3 YES NO FANS GEF-1-1 TO 3 GARAGE EXHAUST FANS - LEVEL 1 GARAGE LEVEL 1 N CO/PROPANE SENSOR SEE NOTE 5 NO YES GEF-2-1 TO 3 GARAGE EXHAUST FANS - LEVEL 2 GARAGE LEVEL 2 N CO/PROPANE SENSOR SEE NOTE 5 NO YES EPF-R-1 ELEVATOR 1 PRESSURIZATION ROOF Y OFF ON YES YES EPF-R-2 ELEVATOR 2 PRESSURIZATION ROOF Y OFF ON YES YES SPF-R-1 STAIR A PRESSURIZATION ROOF Y OFF ON YES YES SPF-R-2 STAIR B PRESSURIZATION ROOF Y OFF ON YES YES SPF-R-3 STAIR C PRESSURIZATION ROOF Y OFF ON YES YES SEF-R-1 SMOKE EXHAUST FAN ROOF Y OFF SEE NOTE 4 YES YES SEF-R-2 SMOKE EXHAUST FAN ROOF Y OFF I SEE NOTE 4 YES YES SEF-R-3 SMOKE EXHAUST FAN ROOF Y OFF SEE NOTE 4 YES YES NOTES 1 ALARM MODE INITATED BY SPRINKLER FLOW, MANUAL PULL STATION OR SMOKE DETECTOR. MANUAL PULL STATION DOES NOT ACTIVATE SMOKE EXHAUST. 2 FAN STATUS BY CURRENT SENSING RELAY INSTALLED BY ELECTRICAL CONTRACTOR. 3 NORMAL MODE CONTROLLED BY HVAC CONTROLS. DURING ALARM CONTROLLED BY FIRE ALARM PANEL (FACP) TO AUTOMATICALLY SHUT DOWN. 4 TURNS ON WHEN CALL FROM SMOKE DETECTOR IN CORRIDOR OF ACTIVE SMOKE CONTROL ZONE, OR BY FIRE DEPARTMENT AT FIREFIGHTER SMOKE CONTROL PANEL (FSCP). 5 PROVIDE SINGLE SWITCH AT FIREFIGHTER SMOKE CONTROL PANEL (FSCP) TO ACTIVATE ALL GARAGE FANS. END OF MATRIX SMOKE CONTROL MATRIX - MOTORIZED DAMPERS DAMPER # UNIT DESCRIPTION EQUIPMENT # LOCATION NORMAL OPERATION ALARM MODE MONITORED FROM FIREFIGHTER SMOKE CONTROL PANEL (FSCP) MANUAL CONTROL FROM FIREFIGHTER SMOKE CONTROL PANEL (FSCP) DAMPER MODEL FIRE RATING TEMPERATURE RATING LEAKAGE CLASS FAIL NOTES MD-1 NORTH MAKE-UP AIR UNIT MUA-R-1 ROOF OPEN CLOSED FOR CLOSED POSITION NO GREENHECK SMD-201 N/A N/A UL 555S CLASS 1 CLOSED MD-2 SOUTH MAKE-UP AIR UNIT MUA-R-2 ROOF OPEN CLOSED FOR CLOSED POSITION NO GREENHECK SMD-201 N/A N/A UL 555S CLASS 1 CLOSED MD-3 ELEVATOR 1 PRESSURIZATION EPF-R-1 ROOF CLOSED OPEN YES YES GREENHECK SMD-201 N/A N/A UL 555S CLASS 1 OPEN OPEN WHEN FAN EPF-R-1 OPERATES. MD-4 ELEVATOR 2 PRESSURIZATION EPF-R-2 ROOF CLOSED OPEN YES YES GREENHECK SMD-201 N/A N/A UL 555S CLASS 1 OPEN OPEN WHEN FAN EPF-R-2 OPERATES. MD-5 ELEVATOR 1 RELIEF EPF-R-1 ROOF CLOSED OPEN YES YES GREENHECK SMD-201 N/A N/A UL 5555 CLASS 1 OPEN OPEN WHEN FAN EPF-R-1 OPERATES AND ELEVATOR IS IN A NON- RECALL CONDITION. MD-6 STAIR A PRESSURIZATION SPF-R-1 ROOF CLOSED OPEN YES YES GREENHECK SMD-201 N/A N/A UL 555S CLASS 1 OPEN WHEN OPEN, INITIATES OPERATION OF THE FAN SPF-R-1. SEE NOTE 1 8 MD-7 STAIR B PRESSURIZATION SPF-R-2 ROOF CLOSED OPEN YES YES GREENHECK SMD-201 N/A N/A UL 555S CLASS 1 OPEN WHEN OPEN, INITIATES OPERATION OF THE FAN SPF-R-2. SEE NOTE 1 8 MD-8 STAIR C PRESSURIZATION SPF-R-3 ROOF CLOSED OPEN YES YES GREENHECK SMD-201 N/A N/A UL 555S CLASS 1 OPEN WHEN OPEN, INITIATES OPERATION OF THE FAN SPF-R-3. SEE NOTE 1 8 MD-9 SMOKE EXHAUST FAN SEF-R-1 ROOF CLOSED REFER TO SMOKE CONTROL MATRIX - SMOKE EXHAUST YES YES GREENHECK SMD-201 N/A N/A UL 555S CLASS 1 OPEN WHEN OPEN, INITIATES OPERATION OF FAN SEF-R-1. MD-10 SMOKE EXHAUST FAN SEF-R-2 ROOF CLOSED REFER TO SMOKE CONTROL MATRIX - SMOKE EXHAUST YES YES GREENHECK SMD-201 N/A N/A UL 555S CLASS 1 OPEN WHEN OPEN, INITIATES OPERATION OF FAN SEF-R-2. MD-11 SMOKE EXHAUST FAN SEF-R-3 ROOF CLOSED REFER TO SMOKE CONTROL MATRIX - SMOKE EXHAUST YES YES GREENHECK SMD-201 N/A N/A UL 555S CLASS 1 OPEN WHEN OPEN, INITIATES OPERATION OF FAN SEF-R-3. _ NOTES 1 MOTORIZED DAMPER FOR STA RWELL PRESSURIZATION CONTROLLED FROM FIRE ALARM CONTROL SYSTEM. DAMPER SHALL FAIL OPEN., 2 MANUAL CONTROL FOR FAN SHOULD OVERRIDE BEING DISABLED FROM AUTOMATIC ACTUATION IF DAMPER IS NOT CONFIRMED IN OPEN POSITION. 3 REFER TO SMOKE CONTROL MATRIX- SMOKE EXHAUST DAMPERS FOR FIRE/SMOKE DAMPERS WITHIN CORRIDORS. 4 ALL OTHER OPENINGS IN FIRE RATED / SMOKE RATED WALLS TO BE PROTECTED BY: GREENHECK FSD-211 COMBINATION FIRE/SMOKE DAMPER. TEMP RATING: 165°F; UL 555 REFER TO ARCH DWGS FOR WALL RATING; LEAKAGE CLASS: UL555S CLASS 1; FAIL CLOSED. END OF MATRIX SMOKE CONTROL MATRIX - SMOKE EXHAUST DAMPERS SMOKE CONTROL DAMPER # SMOKE CONTROL ZONE EQUIPMENT DESCRIPTION EMERGENCY POWER REQUIRED (YIN) NORMAL OPERATION DEFAULT ALARM MODE FLOOR IN ALARM (MODIFICATION TO DEFAULT ALARM MODE) 1 2 3 4 5 6 7 SCD-7-1 7th FLR RESIDENTIAL SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-7-2 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-7-3 SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-7-4 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-7-5 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-6-1 6th FLRSUPPLY RESIDENTIAL SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-6-2 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-6-3 FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-6-4 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-6-5 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-5-1 5th FLR RESIDENTIAL SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-5-2 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-5-3 SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-5-4 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-5-5 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-4-1 4th FLR RESIDENTIAL SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-4-2 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-4-3 SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-4-4 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-4-5 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-3-1 3rd FLR RESIDENTIAL SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-3-2 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-3-3 SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-3-4 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-3-5 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-3-6 SUPPLY FRE/SMOKE DAMPER FOR SALON 315 Y OPEN CLOSED SCD-2-1 2. FLR RESIDENTIAL SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-2-2 SMOKE EXHAUST FIRE/SMOKE DAMPER Y CLOSED CLOSED NOTE 1 SCD-2-3 SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-2-4 SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED SCD-1-1 1st FLR SUPPLY FIRE/SMOKE DAMPER Y OPEN CLOSED NOTES 1 AUTOMATICALLY OPENS ON CALL FROM SMOKE DETECTOR WITHIN CORRIDOR. MANUAL OPERATION AT FIREFIGHTER SMOKE CONTROL PANEL (FSCP BY FIRE DEPARTMENT. WHEN OPEN, ACTIVATES SMOKE EXHAUST FAN. 2 SUPPLY FIRE/SMOKE DAMPER: GREENHECK FSD-211; TEMP RATING: 165°F; FIRE RATING: UL 555 1-1/2 HOUR; LEAKAGE CLASS: UL555S CLASS 1; FAIL CLOSED SMOKE EXHAUST FIRE/SMOKE DAMPER: GREENHECK FSD-211; TEMP RATING: 350°F; FIRE RATING: UL555 1-1/2 HOUR; LEAKAGE CLASS: UL555S CLASS 1; FAIL CLOSED 3 ON FIREFIGHTER SMOKE CONTROL PANEL, PROVIDE ONE ROTARY SWITCH PER FLOOR (EXHAUST, AUTOMATIC, CLOSED). END OF MATRIX CITY OF PERMIT CENTER C M OCEAN PARK MECHANICAL 4283, 14900 INTER URBAN AVE. TELEPHONE 206-674.4553 SEATTLE, WA 98168 FACSIMILE 206-6744564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE SMOKE CONTROL MATRICES DATE APRIL 2018 DRAWN BY DL SCALE NOT TO SCALE MO.3 l� ENCLOSED PARKING GARAGE VENTILATION: SECONDARY PARKING 100B: 3,181 S.F. CI 0.75 CFM PER SF = 2,400 CFM PROVIDE (1) 2,500 CFM GARAGE TRANSFER FAN. END SWITCH ON CO/N021-1 WIRED TO GTF-1-2. ELECTRICAL CONTRACTOR SHALL SUPPLY DIESEL FUEL FIRED EMERGENCY GENERATOR, SUBBASE FUEL TANK, MUFFLER, AND REMOTE FUEL FILL STATION. IN ACCORDANCE WITH GENERATOR'S INSTRUCTIONS, MECHANICAL CONTRACTOR SHALL 'INSTALL DUCTING FROM RADIATOR TO EXHAUST LOUVER, DUCTING FROM AIR INTAKE LOUVER TO ROOM FOR COMBUSTION AIR, ENGINE EXHAUST PIPE FROM MUFFLER TO DISCHARGE POINT, SUBBASE FUEL TANK VENTS TO EXTERIOR WALL (MINIMUM 5'-0" FROM BUILDING OPENINGS), AND PIPING FROM FUEL FILL STATION .TO SUBBASE TANK. ENGINE EXHAUST (WITH 2" CALCIUM 1 ,SILICATE INSULATION) 3"4 SUBBASE ANK EMERGENCY'VENT 2 0-SUBBASE TANK NORMAL VENT 3"0 SUBBASE TANK EMERGENCY VENT 2"0 FUEL, FILL FROM FUEL FILL STATION I TO SUBBASE FUEL TANK. -END-SW(TOH ON CO/N021-3 WIRED TO GOEt1` 1. LOUVER AT HIGH LEVEL 14"x8" OUTDOOR AIR DOWN TO LOW 4"x8" EXHAUST ABOVE. 14"x8" OUTDOOR AIR W ID, F. GARAGE ANSFER FAN -1-8 MOUNTED TO 60"x24" IN 2 HOUR FIRE RATED ENCLOSURE FUEL BY ELEC MINIMUM 5'-0 OFFICES SERVED BY A DEDICATED OUTDOOR AIR 0 0 ® 0 OTHERS INCLUDING DUCTS TO TO LEVEL 2 TO EN VENTILATE GARAGE LEVEL 1. TO LEVEL 2 TO VENTILATE GARAGE LEVEL 1. END OF LINE FOR CONTROLS CIRCUIT AEI IOW END SWTCH ON CO/N021-4 WIRED TO GV-1-7. TRASH/RECYCLE IS VENTILATED ,BY 'TRASH CHUTE„FAN EF-R-1. - -FROM ;FUEL FILL TRANSFER-ORILLES LOW STATION TO LEVEL. SUBBASE FUEL OM BUILDING SHALL_BE, SQUARE INCHES PER kVA. MINIMUM 15.6 SQUARE FEET. 20 SQUARE FEET PROVIDED. ENTRY VEST!. WIRED TO FC- 20"x13" RA TA 0"x20" RA TA 6"x10" FA 650 17,1 GREAT R.OM "x24" Nri, 96 KITCHEN EXHAUST DUCT SS P L ON EACH FLOOR. TH F RATED DUCT WRAP AND AIR DUCT FA. NSULAT1ON ON OUTDOOR THERMOSTAT.WTH CO2 FOR DEMAND CONTROL VEN-TILATI9N. UIDOOR AIR DAMPER SHALL BE 0 OPENED IN R SPONSE TO CO2 LEVEL camas cd) ANDOVER PARK E. BE MINIMUM 3'-0" E OPENINGS, B,Apovt BY 0 ENCLOSED PARKING GARAGE VENTILATION: PROVIDE (3) 6,000 CFM GARAGE EXHAUST FANS -1-20-Pv1P,:-120/1 60 CIRCUIT BY _IELECIRICAL,,CO ACTOR. SLAB. TYPICAL PERMIT CENTER FV1] OCEAN PARK MECHANICAL 4283, 14300 INTER URBAN AVE. TELEPHONE 2.6744553 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE LEVEL 1 MECHANICAL DATE APRIL 2018 DRAWN BY DL SCALE Mil 0 4,4 HOT TUB BOILER BY OTHERS (350CFH) 6"0 PVC FOR COMBUSTION AR. FIRE RATED ENCLOSURE BY OTHERS. 6"0 CPVC FOR EXHAUST FLUE. SEPARATION BETWEEN INTAKE AND EXHAUST: _MINIMUM 1',6' AND MAXIMUM 5.-0". EXHAUST 6" MINIMUM FROM WALL. INTAKE TO BE A DOWNTURN ELBOW. END SWITCH ON CO/N022-1 WIRED TO GTF-2-2 & 3. END SWITCH ON CO/N022- WRED TO GTF-2-1. UNIT c.„7,YITE AI Tl / / / / / 0 R7 THERMAL INSULATION ON OUTDOOR AIR DUCT. THE, r VW AirilIAMC4r. A.:" AraCAW9 I tiViraZ4V45 I' 14 x10 _ prim ,,,1P ', EI 117 .... 1, cd ,1 ' GAME ROOM 211 , 4"x14" j -2-1 (1) 1'0 CONDUIT Lil'1411.111-J.1 FANS SUSPENDED FROM - STRUCTURE MATH 2" STATIC DEFLECTION SPRING ISOLATION HANGERS. FLEXIBLE DUCT CONNECTION. GARAGE EXHAUST .VE MINIMUM 3'40TO OPERABLE OPENINGS. 8'-9" x 4'-3" OPENING LT: LENGTH OF 2' THICK DUCT LINING. 16%20" FA FIRE ENCLOSURE BY OTHERS. END SWITCH ON CO/N022-2 WIRED TO GTF-2-4. -C( WHEEL STOPS - (BY OTHERS). 4'-0"x7'-6" TRANSFER FROM LEVEL 1 TO la VENTILATE GARAGE -LEVEL T. GRATE -BY OTHERS. 4.-0"x4'-0" TRANSFER FROM LEVEL 1 TO -VENTILATE GARAGE - - LEVEL 1. GRATE BY OTHERS. :10 w 20x13" ;RA:173- 20"x16" SA 20x20"RA B (1) 10 CONDUIT 10"x10" FA FIRE RATED ENCLOSURE BY OTHERS. 1 S-1 12 6" 200 I - — - -------- END OF UNE FOR CONTROLS CIRCUIT ------------------ 61. r_10. _ GARAGE-EXHAUST-LOUVER. MINIMUM 3'-0* TO OPERABLE OPENINGS. VMs FOR GARAGE EXHAUST FANS GEF-2-1 TO GEF-2-3 MOUNTED VERTICALLY ON WALL --- 1, , EXHAUST ANO.MAKE-UP AIR DUCTS FOR FUThRE KITCHEN_ HORIZONTAL DUCTING ON LEVEL 1 BY, OTHERS. 20%24" N96 KITCHEN EXHAUST DUCT FA WITH FIR RATED DUCT WRAP AND ACCESS PANEL ON EACH FLOOR. 20"X24' MAIIE-UP AIR DUCT FA. 44"x14" TB. R7 THERMAL INSULATION ON OUTDOOR AIR DUCT. ENRDVA SNATCH N C0/N022-3 WIRED TO co sENsoR 5'-0" AFF NO2 SENSOR it.I1'-6" AFF - CONDUIT IN SLAB ABOVE BY CONTROLS CONTRACTOR. WRING IN CONDUIT BY CONTROLS CONTRACTOR. ENCLOSED PARKING GARAGE VENTILATION: LEVEL 1: 23,126 S.F. MI 0.75 CFM PER SF = 17,350 CFM LEVEL 2: 27,915 S.F. MI 0.75 CFM PER SF = 20,940 CFA LEVEL 1 & 2: TOTAL OF 38,400 CFM PROVIDE (3) 12,800 CFM GARAGE EXHAUST FANS GEF-2-1 TO GEF-2-3 FOR A TOTAL OF 38,400 CFM. JUNCTION BOX IN SLAB. TYPICAL. 1"0 CONDUIT END SWTCH OIJ CO/N022-6 WIRED TO GIF-12-6. NOTES. RECEIVED CrrY OF TUKWILA PERMIT CENTER 1. APARTMENTS SHALL HAVE A VERTICAL TERMINAL HEAT PUMP (VTHP). SUPPLY AIR GRILLES SHALL BE TYPE 1S-1 (LIVING ROOM - 12%8, BEDROOM - 12"x6"). FLEXIBLE DUCT TO GRILLES (LIVING ROOM - 100, BEDROOM - 80). 2. APARTMENTS SHALL HAVE 750 W ELECTRIC HEATERS IN EACH BEDROOM. HEATERS TO BE SUPPLIED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. HEATER SHALL BE INTERLOCKED TO THE VTAC TO ENSURE THAT SIMULTANEOUS HEATING AND COOLING DOES NOT OCCUR PER 2015 WSEC SEcTION C403.2.4.1. 3. KITCHEN EXHAUST DUCTS SHALL BE CONSTRUCTED OF 60 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TIGHT. 4. DRYER DUCTING SHALL BE 40 SMOOTH METAL INTERIOR FINISH. IT SHALL BE EQUIPPED MATH BACKDRA7 DAIAPER. NO SCREWS. 5. TOILET R001A DUCTING SHALL BE ENDRYECONSTRUCTED OF 5"0 GALVANIZED STEEL WTH SMOOTH INTERIOR FINISH AND TO BE AIR TIGHT. DUCT SERVING MULTIPLE TOILET ROOM FAN(S) SHALL BE 6"0. 6. KITCH, R, TOILET ROOM EXHAUST HOOD SHALL BE 3'-0' FROM ANY OPERABLE OPENINGS. (EXHAUST HOOD BY OTHERS). 7. OUTDOOR AIR TO APARTMENTS THROUGH WNDOW TRICKLE VENTS (SUPPLIED BY OTHERS). 1 BEDROOM APARTMENTS: THREE (3) MON TRIM VENT SM (4 MIN. EACH). 2 BEDROOM APARTMENTS: FIVE (5) MON TRIM VENT SM (4 SQ.IN. EACH). B. DRYER CI:TS SHALL HAVE A 20" WDE x 14" HIGH GRILLE IN EACH DOOR. 9. INTERIOR EDROOMS SHALL HAVE MECHANICAL LAW/N. TRANSFER FAN TF-1. 10,DRY-ERS E WHIRIPOOLIAODEL .7_IHEDW VENT (SUPPLIED BY OWNER). MAXIMUM DUCT LENGTH iq 160 FEET WITH NO 90' ELBOWS. SU 0 FEET FROM MAXIMUM LENGTH FOR EACH 90. ELBOW. C mi OCEAN PARK MECHANICAL 4283, 14900 INTER URBAN AVE. TELEPHONE 206-67.553 SEATFLE, WA 98168 FACSIMILE 206-6744564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE LEVEL 2 MECHANICAL DATE APRIL 2018 DRAWN BY DL SCALE A",i'-o" M1.2 Ci) 0 0 0 0 UNI1 C.8 , sr, 6"0 X7,20, . , EF, 8'87' 44, 84= XHWE 8,88-8,*42-84 cI,4 t PATIO 2 • 4414'4-I --,71 -8' B 2 • E.2 PA,C, - - - EF-2 CORRP1OP E 2 REEF WIft.TU)RTRO FC-7 OR ft;28-,ECONOVIZER OPERATION., 444 $MVCKOAFT DAMPER AND " TORIZED'DAMPER,'MOTORIZED „ER OPEN WHEN -FC-7 OR -8 IS IN TREE CABLING, OTHERWISE, CLOSED. FAN COIL UNIT MTH 100% OUTDOOR AIR ECONOMIZER INCLUDING MOTORIZED DAMPER ON RETURN AIR AND MOTORIZED DAMPER, ON OUTDOOR AIR. 884 B,2 PATIO , UNE, B 2 1,27 9 LOW LEVEL HIGH LEVEL © HIGH LE 10.0 1, 1" EX AREE, tiNIT 7,23 -fp S 1 2"x6" 240 MT A.2 ‘521 CL.,25E1 DOOR GRILLE FOR RELIEF AIR DURING ECONOMIZER OPERATOR. 40 HIGH LEVEL FOR RELIEF isivAirraim 'PArggkEEFCgLRMTEERF OPERATION. 6 ° 6"0 FL, L-17 SIAM • ELF,- E-52 e1rTA -7 LT(' MT CA 512 1,52S Er 84, 8887,2477a8a7,,,17:- t7.1,2-1,7-7,2122=„7-1.- - €2, [1 IL EXHAUST AKE-UP AIR DUCTS FOR FUTURE HORIZONTAL DUCTNG ON LEVEL 1 i440 THERS. 20x24" NFPA 96 KITCHEN EXHAUST DUCT FA WITH FIRE RATED DUCT WRAP AND ACCESS PANEL ON EACH FLOOR. 20624" MARE -UP AIR DUCT FA. 44 NOTES: RECEIVED CITY OF TUKWILA PERMIT CENTER I. APARTME,TS SHALL HAVE A VERTCAL TERMINAL HEAT PUMP (.1P). SUPPLY AIR GRILLES SHALL BE TYPE'S-1 (LIVING ROOM - 12x8, BEDROOM - 12x6"). FLEXIBLE DUCT TO GRILLES (LIVING ROOM - 10"0, BEDROOM - 8"0). 2. APARTMEIJTS SHALL HAVE 750 W ELECTRIC HEATERS IN EACH BEDROOM. HEATERS TO BE SUPPLIED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. HEATER SHALL BE INTERLOCKED TO THE VTA TO ENSURE THAT SIMULTANEOUS HEATNG AND COOLING DOES NOT OCCUR PER 2015 WSEC SECTION C403.2.4.1. 3. KITCHEN EXHAUST DUCTS SHALL BE CONSTRUCTED OF 60 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TIGHT. K. DRYER DUCTING SHALL BE 40 SMOOTH METAL INTERIOR FINISH. IT SHALL BE EQUIPPED VA. BACKDR, DAMPER. NO SCREWS. 5. TOILET ROOM DUCTING SHALL BE CONSTRUCTED OF 5.0 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TGHT. DUCT SERVING MULTPLE TOILET ROOM FAN(S) SHALL BE 60. 6. KITCHEN, DRYER, TOILET ROOM EXHAUST HOOD SHALL BE 0-0" FROM ANY OPERABLE OPENINGS. (EXHAUST HOOD BY OTHERS). OUTDOOR AIR TO APARTMENTS THROUGH WINDOW TRICKLE VENTS (SUPPLIED BY OTHERS). 1 BEDROOM APARTMENTS: THREE (3) TITON TRIM VENT SM (4 SQ.IN. EACH). 2 BEDROOM APARTMENTS: FIVE (5) TTON TRIM VENT SM (4 SQ.IN. EACH). DRYER CLIDSETS SHALL HAVE A 20" WIDE x 14HIGH GRILLE IN EACH DOOR. 9. INTERIOR BEDROOMS SHALL HAVE MECHANICAL LATION. TRANSFER FAN YE-F.-10.DR.S -BE -WHIRIP-00L-MODEL-WMVENT (SUPPLIED BY OWNER). MAXIMUM DUCT LENGTH 15 160 FEET WITH NO 90. ELBOWS. SUU 9. 10 FEET FROM MAXIMUM LENGTH FOR EACH 90. ELBOW. m) OCEAN PARK MECHANICAL .283, 14300 IN. URBAN AVE. TELEPHONE 20.674-4553 SEATTLE, WA 68168 FACSIMILE 2066744564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE LEVEL 3 MECHANICAL DATE APRIL 2018 DRAWN BY DL SCALE 1/8",=,1'-0" M1.3 ED ED 0 0 ED 0 0 ED hLINE ED ED ED ED ED ED CD ED ED ED o EFT2I J 750W I I 750W I , 44, 50, SF' UV, 442 , 4,2 F- • I f-r--11 SI 44; 2"0+ ITA • ,1,4 L • 'so 75PW FSD -\\ UrNET C 1277 F.,' N 1. EXHAUST A MAKE-UP AIR DUCTS FOR FUTURE KIT EN. HORIZONTAL DUCTING ON LEVEL 1 BY THERS. 20%24" NFP 96 KITCHEN EXHAUST DUCT FA W. FIR4 RATED DUCT WRAP AND ACCESS PANEL ON EACH FLOOR. 20.X24" MA1E-UP AIR DUCT FA. ED ED NOES. RECEIVED 1'1 OF TUKVilLA EPSIUTIT CENTER 1. APARTMENTS SHALL HAVE A VERTICAL TERMINAL HEAT PUMP (VTHP). SUPPLY AIR GRILLES SHALL BE TYPE 5-1 (LIVING ROOM - 12x8, BEDROOM - 12"x6"). FLEXIBLE DUCT TO GRILLES (LIVING R3OM - 10"0, BEDROOM - 8.0). 2. APARTMENTS SHALL HAVE 750 W ELECTRIC HEATERS IN EACH BEDROOM. HEATERS TO BE SUPPLIED, AND INSTALLED BY THE ELECTRICAL CONTRACTOR. HEATER SHALL BE INTERLOCKED TO THE VTA8 TO ENSURE THAT SIMULTANEOUS HEATING AND COOLING DOES NOT OCCUR PER 2015 WSEC SEcT1ON C403.2.4.1. 3. KITCHEN LXHAUST DUCTS SHALL BE CONSTRUCTED OF 6-0 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TORT. 4. DRYER DUCTING SHALL BE 40 SMOOTH METAL INTERIOR FINISH. IT SHALL BE EQUIPPED WITH BACKDRA7 DAMPER. NO SCREWS. 5. TOILET ROM DUCTING SHALL BE CONSTRUCTED OF 5"0 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TIGHT. DUCT SERVING MULTIPLE TOILET ROOM FAN(S) SHALL BE 6"0. 6. KITCHEN, pRYER, TOILET ROOM EXHAUST HOOD SHALL BE 3.-0" FROM ANY OPERABLE OPENINGS. (EXHAUST HOOD BY OTHERS). 7. OUTDOORIAIRiTO APARTMENTS THROUGH WINDOW TRICKLE VENTS (SUPPLIED BY OTHERS). 1 BEDRO APARTMENTS: THREE (3) MON TRIM VENT SM (4 SQ.IN. EACH). 2 BEDRO APARTMENTS: FIVE (5) MON TRIM VENT SM (4 SQ.IN. EACH). 8. DRYER CLPSETS SHALL HAVE A 20" WIDE x 14" HIGH GRILLE IN EACH DOOR. 9. INTERIOR 8EDROOMS SHALL HAVE MECHANICAL LATION. TRANSFER FAN TF-1. - 10.DRY.ER.S.110-BE MIRLP-001.-UODEL--.7-1HED VENT (SUPPUED BY OWNER). MAXIMUM DUCT LENGTH I 160 FEET WITH NO 90' ELBOWS, SUL r 10 FEET FROM MAXIMUM LENGTH FOR EACH 90' ELBO C M OCEAN PARK MECHANICAL 3, 14900 INTER URBAN AVE TELEPHONE 206.744553 SEATTLE, WA 98168 FACSIMILE 2.674-4564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT y(2,0/b,v DRAWING TITLE LEVEL 4 MECHANICAL DATE APRIL 2018 DRAWN BY DL SCALE 1/8"-V-0” M1.4 0 ED 0 0 0 8 0 ITO HLINE AT ' .777;7 EF721 MOW EF,71 — - - EF--11 55.5, ,,12"0 TA 'ISEW-71 UNIT A 2 LI '755 5 555,5 -551 ,FF UNIT G 277 N EXHAUST ANP MAKE—UP AIR DUCTS FOR FUTURE KIT EN. HORIZONTAL DUCT,. ON LEVEL 1 BY OTHERS. 20%24" NFPA 96 KITCHEN EXHAUST DUCT FA WITH FIRE RATED DUCT WRAP AND ACCESS PANEL ON EACH FLOOR. 20"X24" MAI1E—UP AIR DUCT FA. 10- NOTES: IRECEIVE.) CITY OF TUKWILA PERMIT CENT Efs, 1. APARTMENTS SHALL HAVE A VERTICAL TERMINAL HEAT PUMP (VTHP). SUPPLY AIR GRILLES SHALL BE TYPE S-1 (LIVING ROOM — 12%8", BEDROOM — 12"x6"). FLEXIBLE DUCT TO DRIVES (LIVING ROOM — 100, BEDROOM — 80). 2. APARTME TS SHALL HAVE 750 W ELECTRIC HEATERS IN EACH BEDROOM. HEATERS TO BE SUPPLIED, AND INSTALLED BY THE ELECTRICAL CONTRACTOR. HEATER SHALL BE INTERLOCKED TO THE VTAO TO ENSURE THAT SIMULTANEOUS HEATING AND COOLING DOES NOT OCCUR PER 2015 WSEC SEcTION C403.2.4.1. 3. KITCHEN LXHAUST DUCTS SHALL BE CONSTRUCTED OF 60 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TIGHT. 4. DRYER DUCTING SHALL BE 4.0 SMOOTH METAL INTERIOR FINISH. IT SHALL BE EQUIPPED WITH BACKDRA-T DAMPER. NO SCREWS. 5. TOILET RQOM DUCTING SHALL BE CONSTRUCTED OF 50 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TIGHT. DUCT SERVING MULTIPLE TOILET ROOM FAN(S) SHALL BE 60. 6. KITCHEN, (DRYER, TOILET ROOM EXHAUST HOOD SHALL BE 3-0" FROM ANY OPERABLE OPENINGS. (EXHAUST HOOD BY OTHERS). 7. OUTDOOR AIR TO APARTMENTS THROUGH WINDOW TRICKLE VENTS (SUPPLIED BY OTHERS). 1 BEDROCM APARTMENTS: THREE (3) TITON TRIM VENT SM (4 SQ.IN. EACH). 2 BEDROOM APARTMENTS: FIVE (5) DION TRIM VENT SM (4 SQ.IN. EACH). 8. DRYER CLOSETS SHALL HAVE A 20" WIDE x 14" HIGH GRILLE IN EACH DOOR. 9. INTERIOR BEDROOMS S LATOTRSFER FAN TF-1. 10.-DRYERS.-Z-BE .1R1,001-440DEL-WED71HEDW VENT (SUPPUED BY OWNER). MAXIMUM DUCT LENGTH I 160 FEET WITH NO 90. ELBOWS. SU FEET FROM MAXIMUM LENGTH FOR EACH 90. ELBO C OCEAN PARK MECHANICAL .283,4900 INTER URBAN AVE. TELEPHONE 20.74-4553 SEAM, WA 981. FACSIMILE 206-674-4564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT 1VA,n,01- wzo/Zoli DRAWING TITLE LEVEL 5 MECHANICAL DATE APRIL 2018 DRAWN BY DL SCALE 1/8"--1'-0" M1.5 HUNE 0 4 , 0 0 17- 0 UNIT E; 111 2 CORRIDOR' CD 0 0 '1,77,1-1.777777,777",;,„ _FS BEF-21i,: SD AP 7,1 Elf" - r I EF-2j EXHAUST AN MAKE-UP AIR DUCTS FOR FUThRE KIT EN. HORIZONTAL DUCTNG ON LEVEL 1 BY NERS. 20%24" NFP 96 KITCHEN EXHAUST DUCT FA WITH RATED DUCT WRAP AND ACCESS PANEL ON EACH FLOOR. 20-X24" MAI1E-UP AIR DUCT FA. Mi NOTES: I CITvil,,,, PERM(T CENTER 1. APARTMENTS SHALL HAVE A VERTICAL TERMINAL HEAT PUMP (VTHP). SUPPLY AIR GRILLES SHALL BE TYPE S-1 (LIVING ROOM - 12"xe, BEDROOM - 12.x6"). FLEXIBLE DUCT TO GRILLES 2. APARTMENTS SHALL HAVE 750 W ELECTRIC HEATERS IN EACH BEDROOM. HEATERS TO BE (LIVING - 100, BEDROOM - 8.0). SUPPUED, AND INSTALLED BY THE ELECTRICAL CONTRACTOR. HEATER SHALL BE INTERLOCKED TO THE VTA01 TO ENSURE THAT SIMULTANEOUS HEATING AND COOLING DOES NOT OCCUR PER 2015 IVSEC SEGTON C403.2.4.1. 3. KITCHEN LXHAUST DUCTS SHALL BE CONSTRUCTED OF 60 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TGHT. 4. DRYER DUCTNG SHALL BE AN SMOOTH METAL INTERIOR FINISH. IT SHALL BE EQUIPPED WITH BACKDR, DAMPER. NO SCREWS. 5. TOILET RQOM DUCTNG SHALL BE CONSTRUCTED OF 50 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TIGHT. DUCT SERVING MULTPLE TOILET ROOM FAN(S) SHALL BE 60. 6. KITCHEN, (DRYER, TOILET ROOM EXHAUST HOOD SHALL BE 3.-0" FROM ANY OPERABLE OPENINGS. (EXHAUST HOOD BY OTHERS). 7. OUTDOOR,IAIR TO APARTMENTS THROUGH WINDOW TRICKLE VENTS (SUPPLIED BY OTHERS). 1 BEDRO M APARTMENTS: THREE (3) TITON TRIM VENT SM (4 SQ.IN. EACH). 2 BEDRO M APARTMENTS: FIVE (5) TTON TRIM VENT SM (4 SQ.IN. EACH). B. DRYER NOSETS SHALL HAVE A 20" WIDE x 14HIGH GRILLE IN EACH DOOR. 9. INTERIOR :BEDROOMS SHALL HAVE MECHANICAL LATON. TRANSFER FAN TF-1. BE MIRLP-00,1A0DEL-. VENT (SUPPLIED BY OWNER). MAXIMUM DUCT LENGTH I 160 FEET WITH NO 90' ELBOWS. SLAB' 10 FEET FROM MAXIMUM LENGTH FOR EACH 90' ELBOIN. MD OCEAN PARK MECHANICAL 483, 14B00 INTER URBAN AVE. TELEPHONE 20.74-4553 SEATI.LE, WA 58168 FACSIMILE 20.7445. PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE LEVEL 6 MECHANICAL DATE APRIL 2018 DRAWN BY DL SCALE A"=i'-o" M1.6 WIRED TO SPF-R- . WIRED TO SPF-R-3. I 750W I , " UNIT A 4, ,LEV 750W I --- EXHAUST AND MAKE-UP AIR DUCTS FOR FUTURE KITCHEN. HORIZONTAL DUCTING ON LEVEL 1 BY THERS. 20%24" NFP 96 KITCHEN EXHAUST DUCT FA WITH FIR4 RATED DUCT WRAP AND ACCESS PANEL ON EACH FLOOR. 20"X24" MME-UP AIR DUCT FA. NOTES: 1. APARTMENTS SHALL HAVE A VERTICAL TERMINAL HEAT PUMP (VTHP). SUPPLY AIR GRILLES SHALL BE TYPE (LIVING ROOM - 12x8, BEDROOM - 12'x6"). FLEXIBLE DUCT TO GRILLES (LIVING ROOM - 100, BEDROOM - 80). 2. APARTMENTS SHALL HAVE 750 W ELECTRIC HEATERS IN EACH BEDROOM. HEATERS TO BE SUPPLIED, AND INSTALLED BY THE ELECTRICAL CONTRACTOR. HEATER SHALL BE INTERLOCKED TO THE VTA0 TO ENSURE THAT SIMULTANEOUS HEATING AND COOLING DOES NOT OCCUR PER 2015 WSEC SE9T10N C403.2.4.1. 3. KITCHEN EXHAUST DUCTS SHALL BE CONSTRUCTED OF 60 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TIGHT. 4. DRYER DUCTING SHALL BE 4.0 SMOOTH METAL INTERIOR FINISH. IT SHALL BE EQUIPPED WITH BACKDRA7 DAMPER. NO SCREWS. 5. TOILET ROOM DUCTING SHALL BE CONSTRUCTED OF 50 GALVANIZED STEEL WITH SMOOTH INTERIOR FINISH AND TO BE AIR TIGHT. DUCT SERVING MULTIPLE TOILET ROOM FAN(S) SHALL BE 60. 6. KITCHEN, 'DRYER, TOILET ROOM EXHAUST HOOD SHALL BE 3.-0" FROM ANY OPERABLE OPENINGS. (EXHAUST HOOD BY OTHERS). 7. OUTDOOR AIR TO APARTMENTS THROUGH WINDOW TRICKLE VENTS (SUPPLIED BY OTHERS). 1 BEDROCM APARTMENTS: THREE (3) TITON TRIM VENT SM (4 SQ.IN. EACH). 2 BEDROOM APARTMENTS: FIVE (5) TITON TRIM VENT SM (4 SQ.IN. EACH). B. DRYER CLOSETS SHALL HAVE A 20" WIDE x 14" HIGH GRILLE IN EACH DOOR. 9. INTERIOR EDROOMS SHALL HAVE MECHANICAL LATION. TRANSFER FAN TF-1. - -10-DRYERS JO -BE 11,11RWOOL-110DEL-WED-7 0 VENT (SUPPLED BY OWNER). MAXIMUM DUCT LENGTH I 160 FEET WITH NO 90. ELBOWS. S 10 FEET FROM MAXIMUM LENGTH FOR EACH 90. ELBO 1 _EU OCEAN PARK MECHANICAL .283, 14900 INTER URBAN AVE TELEPHONE 2.674-45. SEATTLE, WA 98168 FACSIMILE 2.674-4564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT /61A4-- 11(PMIY DRAWING TITLE LEVEL 7 MECHANICAL DATE APRIL 2018 DRAWN BY DL SCALE 1/8"=V-0" M1 NE MINIMUM 20'-0" FROM EXHAUST. MINIMUM 20'-0" FROM EXHAUST. 18%18" FB 8"x18" (i) 0 BAKER BLVD REFRIGERANT LINES BETWEEN 'CU-R-1 AND DX COOLING COIL BY MECHANICAL CONTRACTOR. CONDENSING UNIT FOR FUTURE KITCHEN BY OTHERS. PIPED TO MAKE-UP AIR UNIT. MAKE-UP AIR UNIT FOR FUTURE KITCHEN BY OTHERS. EXHAUST FAN MOUNTEI% ON TOP OF THE TRATE HUTS. LiibE O, i,..Ktei.,. ABOVE 6"0 EXHAUST FLUE TA 4"0 INTAKE FA w FUTURE KITCHEN EXHAUST FAN BY OTHERS. tJ ems'..+ ����i►�'. w 58' 3" 91' 7" ( 700CFH ) 2' 2 (250CFH 59' 3" LINE OF CAN' EU ABOVE 50' 8" N 16' 24%24" LEVATOR HOISTWAY RELIEF WITH A COUNTER WEIGHTED BACKDRAFT DAMPER, AND A NORMAL CLOSED MOTORIZED DAMPER. MOTORIZED DAMPER OPENS UPON ACTIVATION OF EPF-R-1 WHEN ELEVATOR IS IN A NON -RECALL CONDITION. MINIMUM 200" FROM EXHAUST. EXHAUST AN MAKE-UP AIR DUCTS FOR FUTURE KITC EN. HORIZONTAL DUCTING ON LEVEL 1 BY OTHERS. 20%24" NFP,A 96 KITCHEN EXHAUST DUCT FA WITH FIRE RATED DUCT WRAP AND ACCESS PANEL ON EACH FLOOR. 20"X24" MAKE-UP AIR DUCT FA. 2" THICK DUCT ANDOVER PARK E. 1111144.01 REFRIGERANT LjNES BETWEEN CU-R-2 AND X COOLING COIL BY MECH NICAL CONTRACTOR. MINIMUM 20'-0FROM EXHAUST. DISTANCE TO SiUTH PROPERTY LINE. L_ Ci t `f 02 TEJF;,1Y iLti PERMIT CENTER C JMD OCEAN PARK MECHANICAL N283,14900INTER URBAN AVE. TELEPHONE 2.674-4553 SEATTLE, WA 98168 FACSIMILE 2066744564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT y(7,/ZO/7 DRAWING TITLE ROOF PLAN MECHANICAL DATE APRIL 2018 DRAWN BY DL SCALE %$"=1'-0" M1.8 0 0 0 0 INTAKE AIR LOUVER FOR FAN COIL UNIT FC-2. BUILDING ELEVATION - NORTH SCALE: 1/8" = 1'-0" LEL w ARCHITECTURAL LOUVER FOR VERTICAL TERMINAL HEAT PUMP. INTAKE AIR LOUVER FOR FAN COIL UNITS FC-5 AND FC-6. KITCHEN, DRYER, TOILET ROOM EXHAUST TO BE 3'-0' FROM ANY OPERABLE OPENINGS. EXHAUST TERMINATION BY OTHERS. EXHAUST AIR LOUVER FOR HRV-1. INTAKE AIR LOUVER FOR HEAT RECOVERY VENTILATOR HRV-1. MINIMUM 3'-0" BELOW EXHAUST LOUVER PER 2015 INC 401.4.3. 0 CEEY OF TUKWILA PERMIT CC0TFP �Yll`l-b2�t C M] OCEAN PARK MECHANICAL 4283, 14900 INTER URBAN AVE. TELEPHONE 2066744553 SEATTLE, WA 98168 FACSIMILE 206-6744564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT (Zo/ey 17 DRAWING TITLE NORTH ELEVATION DATE APRIL 2018 DRAWN BY DL SCALE ,"=1'-0" M2.1 ARCHITECTURAL LOUVER FOR VERTICAL TERMINAL HEAT PUMP. EXHAUST AIR LOUVER FOR CATERING KITCHEN. BUILDING ELEVATION - EAST SCALE: 1/8" = 1-0" KITCHEN, DRYER, TOILET R00M EXHAUST TO BE 3'-0" FROM ANY OPERABLE OPENINGS. EXHAUST TERMINATION BY OTHERS. INTAKE AIR LOUVER FOR FAN COIL UNITS FC-3 AND FC-4, AND SUPPLY FAN SF-1-1. RECDVED C/TY 7 T1JK/ •:.LA PERMFT CENTER VI) OCEAN PARK MECHANICAL .283, JAM INTER URBAN AVE. TELEPHONE 2.6744553 SEATTLE, WA 98168 FACSIMILE 20.7.5. PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT y�,Lo�2op� DRAWING TITLE EAST ELEVATION DATE APRIL 2018 DRAWN BY DL SCALE %"=1'-0" PRESSURIZATION - INTAKE AIR LOUVER. EXHAUST LOUVER FOR EMERGENCY GENERATOR --ARCHITECTURAL LOUVER FOR VER,CAL TERMINAL HEAT PUMP. KITCHEN, DRYER, TOILET ROOM EXHAUST TO BE 3.-0" FROM ANY OPERABLE OPENINGS. EXHAUST TERMINATION BY OTHERS. FUEL FILL STATON (SUPPLIED CO ENGINE EXHAUST (WITH 2" CALCIUM SILICATE NSULATON) BY ELECTRICAL CONTRACTOR). 3.0 SUBBASE TANK EMERGENCY VENT MINIMUM 5'--0" FROM BUILDING 2'0 SUBBASE TANK NORMAL VENT OPENINGS. 30 SUBBASE TANK EMERGENCY VENT GARAGE EXHAUST LOUVER. GARAGE EXHAUST LOUVER. MINIMUM 3,1" TO OPERABLE MINIMUM 3-0. TO OPERABLE OPENINGS. ' OPENINGS. '11 CilY c NI] OCEAN PARK MECHANICAL .283,4900 INTER URBAN AVE. TELEPHONE 206-674-4553 SEATTLE, WA 98168 FACSIMILE 2.674-4564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 2/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE SOUTH ELEVATION DATE APRIL 2018 DRAWN BY DL SCALE A".i'-o" M2.3 • --ARCHITECTURAL LOUVER FOR VERTICAL TERMINAL HEAT PUMP. 6"0 PVC COMBUSRON AIR PIPE. MINIMUM 7" FROM WALL DOWNTURN ELBOW WITH INSECT SCREEN. MINIMUM 18" FROM EXHAUST, MAXIMUM 60" FROM EXHAUST. REFER TO FIGURE 10 OF BOILER'S INSTALLATION & OPERATION MANUAL. KITCHEN, DRYER, TOILET ROOM EXHAUST TO BE 3.-0 FROM ANY OPERABLE OPENINGS. EXHAUST TERMINATION BY OTHERS. 60 CPVC EXHAUST VENT PIPE. MINIMUM 6" FROM WALL. KIM INSECT SCREEN. REFER TO FIGURE 10 OF EXHAUST LOUVER FOR EXHAUST AIR INTAKE LOUVER FOR BOILER'S INSTALLATION FANS EF-2-1, EF-2-3. EMERGENCY GENERATOR & OPERATION MANUAL. LA, CU(YOTTLJ PERMIT CENTF, M OCEAN PARK MECHANICAL #283, /4800 INTER URBAN AVE. TELEPHONE 20.7.553 SEATRE, WA 98168 FACSIMILE 20.7.564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE WEST ELEVATION DATE APRIL 2018 DRAWN BY DL SCALE A"..r-o" M2.4 ARCHITECTURAL LOUVER FOR KITCHEN, DRYER, TOILET ROOM EXHAUST TO STAIR A PRESSURIZATION VERTICAL TERMINAL HEAT BE 3'-0" FROM ANY OPERABLE OPENINGS. INTAKE AIR LOUVER. ! PUMP. EXHAUST TERMINATION BY OTHERS. _ _• _ !I , KITCHEN, DRYER, TOILET ROOM EXHAUST TO BE 3.-0. FROM ANY OPERABLE OPENINGS. EXHAUST TERMINATOR BY OTHERS. •;: INTAKE AIR LOUVER FOR FAN COIL UNIT FC-7. MINIMUM 3-0" BELOW RELIEF LOUVER PER 2015 IMC 401.4.3. ARCHITECTURAL LOUVER FOR VERTICAL TERMINAL HEAT PUMP. KITCHEN, DRYER, TOILET ROOM EXHAUST TO ARCHITECTURAL LOUVER FOB_ BE 3'-0" FROM ANY OPERABLE OPENINGS. VERTICAL TERMINAL EXHAUST TERMINATION BOTHERS. INTAKE AIR LOUVER FOR FAN COIL UNIT FE-B. KITCHEN, DRYER, TOILET ROOM EXHAUST TO BE 3.-0" FROM ANY OPERABLE OPENINGS. EXHAUST TERMINATOR BY OTHERS. - _ : INTAKE AIR LOUVER FOR FAN COIL UNIT FC-9. MINIMUM 3'-0" BELOW RELIEF LOUVER PER 2015 IMC 401.4.3. LE!, CEO! OF TUKWII_/- OCEAN PARK MECHANICAL #283, 14500 INTER URBAN AVE. TELEPHONE 2.674-4. SEATTLE, WA B8168 FACSIMILE 206.744564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE COURTYARD ELEVATIONS DATE APRIL 2018 DRAWN BY DL SCALE A",i'-o" SMOKE CONTROL NOTES: 1. REFER TO SMOKE CONTROL MATRICES ON DRAWING MO.3. 2. ALARM MODE INITIATED BY SPRINKLER FLOW, MANUAL PULL STATION OR SMOKE DETECTOR. MANUAL PULL STATION DOES NOT ACTIVATE SMOKE EXHAUST. DURING ALARM MODE MAKE-UP AIR UNITS SHUT DOWN, ALL SMOKE CONTROL DAMPERS ON THE MAKE-UP AIR UNITS CLOSE, ELEVATOR AND STAIR PRESSURIZATION FANS OPERATE. 3. SMOKE EXHAUST FANS SEF-R-1, SEF-R-2, SEF-R-3 TURN ON WHEN CALL FROM SMOKE DETECTOR IN CORRIDOR OF ACTIVE SMOKE CONTROL ZONE, OR BY FIRE DEPARTMENT AT FIREFIGHTER SMOKE CONTROL PANEL (FSCP). SMOKE CONTROL DAMPERS FOR EXHAUST GRILLES ON FIRE FLOOR OPEN. ROOF LEVEL 7 LEVEL 6 LEVEL 5 LEVEL 4 LEVEL 3 LEVEL 2 LEVEL 1 18"x30"-// 18"x30"-Y 18"x30"J 16"x20"-,,` 20%14" A SCD-7-1 SCD-7-2 SCD 6-1 SCD-6-2 SCD-5-1 SCD-5-2 SCD-4-1 �---.- SCD-4 2 SCD-3-1 SCD-2- TYPICAL FOR LEVELS 3 TO 7 HAIR SALON 315 1. ARE DAMPERS ARE NOT REQUIRED WHERE STEEL EXHAUST SUBDUCT EXTENDS A MINIMUM OF 22" VERTICALLY PER 2015 WASHINGTON STATE BUILDING CODE 717.5.3. EXCEPTION 1. 1.1. 2. IN ACCORDANCE WITH 2O15 WASHINGTON STATE BUILDING CODE 717.5.3. EXCEPTION 2. SMOKE DAMPERS ARE NOT REQUIRED WHERE: 2.1 - STEEL EXHAUST SUBDUCTS HAS MINIMUM WALL THICKNESS OF 26 GAGE. .2 2.2 - SUBDUCTS EXTEND AT LESS 22 INCHES VERTICALLY, AND .3 2.3 - EXHAUST FAN EF-R-2 IS INSTALLED AT UPPER TERMINUS OF SHAFT THAT IS POWERED CONTINUOUSLY IN ACCORDANCE WITH SECTION 909.11, TO MAINTAIN A CONTINUOUS UPWARD AIRFLOW TO THE OUTSIDE. 3. TYPE E-1 GRILLE COMPLETE WITH OPPOSED BLADE BALANCE DAMPER. SCD-7-3 18"x30"-//1-4"- SCD7 4 SCD-6-3 18"x30"�� SCD-6-4 SCD-5-3 18"x30"Y 4--- CD-5-4 SCD-4-3 18"x30"-/;I CD-4 4 SCD=3-6 SCD-3-3 S-1 E-1 10"x10"Y SCD-2-4-1, TRASH ROOM (LEVELS 3 TO 7) AND HAIR SALON 315 EXHAUST DIAGRAM SCD-1-1 18"x18" CD 7-5 18"x18" CD 6-5 18"x18" CD-5-5 18%18" CD-4-5 18"x18" CD-3-5 STAIR A SMOKE CONTROL RISER DIAGRAM MAKE-UP AIR UNIT HAS A MOTORIZED INLET DAMPER (AUTOMATICALLY CLOSED WHEN SYSTEM IS NOT IN USE). 7 2" STATIC DEFLECTION SPRING ISOLATOR 12" HIGH CURB AND FLASHING BY GENERAL CONTRACTOR FLEXIBLE DUCT CONNECTION` / GASKETED SCREWS 2" DUCT LINER (R-8) TO FIRST GRILLE FOR ACOUSTICS. MINIMUM R-7 FOR ENERGY CODE. CURB CAP BY MECH. CONTRACTOR CURB & FLASHING BY GENERAL CONTRACTOR MAKE-UP AIR UNIT (MUA-R-#) DETAIL 24"x24" ELEVATOR HOISTWAY RELIEF. MOTORIZED DAMPER NORMALLY CLOSED, AND OPENS EPF-R-1 IS OPERATING AND ELEVATOR IS IN A NON -RECALL CONDITION. VATOR ELEVATOR 2 STAIR C SPRING ISOLATOR WITH 2" STATIC DEFLECTION 12" HIGH CURB AND FLASHING BY GENERAL CONTRACTOR CONDENSING UNIT (CU-R-#) DETAIL RECEIVED CITY OF C MI) OCEAN PARK MECHANICAL M283,14900INTER URBAN AVE. TELEPHONE 2.6744553 SEATTLE, WA 98168 FACSIMILE 2.6744564 PROJECT STERLING SOUTHCENTER 415 BAKER BOULEVARD TUKWILA, WA 98188 REVISIONS DATE DESCRIPTION 12/19/2017 MECH. PERMIT 04/20/2018 REISSUED FOR MECH. PERMIT DRAWING TITLE MECHANICAL DETAILS DATE APRIL 2018 DRAWN BY DL SCALE NOT TO SCALE ti 02-0 M3.1