Loading...
HomeMy WebLinkAboutPermit M17-0202 - JIMERSON ADDITION - EXHAUST FANS, DUCTWORK, AIR SUPPLYJIMERSON ADDITION 12203 47 AVE S MI 7-0202 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL OTC PERMIT 0179001100 Permit Number: M17-0202 12203 47TH AVE S Project Name: JIMERSON ADDITION Issue Date: 5/15/2018 Permit Expires On: 11/11/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: JIMERSON JOHNNY 12203 47TH AVE S , TUKWILA, WA, 98178 JOHNNY JIMERSON 12203 47 AV S , TUKWILA, WA, 98178 OWNER AFFIDAVIT - JIMERSON !I/ Phone: (206) 734-9411 Phone: Expiration Date: DESCRIPTION OF WORK: REAPPLICATION FOR EXPIRED PERMIT M14-0169: INSTALL (5) BATHROOM EXHAUST FANS AND (1) LAUNDRY ROOM EXHAUST FAN WITH DUCTING. INSTALL (1) DRYER EXHAUST DUCT TO OUTSIDE. INSTALL NEW WARM AIR SUPPLY AIR DUCTING TO ADDITION FROM EXISTING FURNACE Valuation of Work: $1,500.00 Type of Work: NEW Fuel type: GAS Fees Collected: $182.33 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 4.114‘6 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local lags regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date:5 / 5 1 cts/ This permit shall become null an void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Type' 1 Hoods, the required grease duct leakage test and light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKu' ��A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.Rov M17 -o24), Mechanical Permit No. 41 Project No. Date Application Accepted: ) ).2 ( 7 Date Application Expires: (p %)---`f (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: I '2 2(.73 47.1 • T` -‘11.1 -,'-ti U) Suite Number: Tenant Name: k i 0 In v. -1.)n / U j y e5i;> Vvk c3C61 55 PROPERTY OWNER Name: `"� `' t J 1.} ii )'1 .� 't )F 1)•-b"t�' .�V� Address: t ZZ(? )1�. 4.v, ,,,, Name: j ''- Phone:2_Q f .Q3L�/ v C� / / Address: ) �� /�� �t`v , r / Cityy�ki 1li ! j Fax: States 4 Zipl e. ) `. CONTACT PERSON - person receiving all project communication Name: `"� `' t J 1.} ii )'1 .� 't )F 1)•-b"t�' .�V� Address: t ZZ(? )1�. 4.v, ,,,, City. j'� j; w r' 1 i State: Zip i Phone:2_Q f .Q3L�/ v C� / / City: Email: Floor: New Tenant: ❑ Yes No MECHANICAL CONTRACTOR INFORMATION Company Name: C3\ivif r Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ �j UCS Desc ibe the scope of work in detail: Use: Residential: New ❑ Commercial: New Fuel Type: Electric ❑ Gas Other: Replacement Relacement H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Qty Furnace <100k btu >10,000 cfm Industrial Furnace >100k btu (-... 9c,OC Floor furnace Ventilation system / Suspended/wall/floor mounted heater 47 dB(A) Incinerator — domestic Appliance vent Incinerator — comm/industrial 60 dB(A) Repair or addition to heat/refrig/cooling system 65 dB(A) l Air handling unit <10,000 cfm Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct .57 dB(A) Ventilation system / Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1 ,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 *Daytim District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45. dB(A) .57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO Signature: Print Name: Mailing Address: \ 2-2_ 0 5 vl,1*QrSv Date: 5 '- 1/ qW State Zip Day Telephone: -+ City \ Applications \Forms -Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT 1 QUANTITY PAID $2,519.82 017-0340 Address: 12203 47TH AVE 5 Apn: 0179001100 $1,796.15 DEVELOPMENT $1,401.32 PERMIT FEE R000.322.100.00.00 0.00 $846.56 PLAN CHECK FEE R000.345.830.00.00 0.00 $550.26 WASHINGTON STATE SURCHARGE 6640.237.114 0.00 $4.50 PUBLIC WORKS $350.00 BASE APPLICATION FEE R000.322.100.00.00 0.00 $250.00 PERMIT ISSUANCE/INSPECTION FEE R000.342.400.00.00 0.00 $50.00 CONSTRUCTION PLAN REVIEW R000.345.830.00.00 0.00 $50.00 TECHNOLOGY FEE $44.83 TECHNOLOGY FEE 1 R000.322.900.04.00 0.00 $44.83 EL17-1039 Address: 12203 47TH AVE S Apn: 0179001100 $122.58 ELECTRICAL $116.74 PERMIT FEE SINGLE FAMILY 1 R000.322.101.00.00 0.00 $116.74 TECHNOLOGY FEE $5.84 TECHNOLOGY FEE 1 R000.322.900.04.00 0.00 ': $5.84 M17-0202 Address: 12203 47TH AVE 5 Apn: 0179001100 $182.33 MECHANICAL $173.65 PERMIT FEE R000.322.100.00.00 0.00 $140.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $8.68 TECHNOLOGY FEE R000.322.900.04.00 I 0.00 $8.68 PG17-0173 Address: 12203 47TH AVE S Apn: 0179001100 $418.76 GAS $99.45 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $66.30 PLUMBING $299.37 PERMIT FEE R000.322.100.00.00 0.00 $266.22 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $19.94 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14490 R000.322.900.04.00 0.00 $19.94 $2,519.82 Date Paid: Tuesday, May 15, 2018 Paid By: ABAY D BEDASSO Pay Method: CHECK 136 Printed: Tuesday, May 15, 2018 11:49 AM 1 of 1 C. SYSTEMS INSPECTION NO. INSPECTI?N'-RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukvvila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro'ect: ±rte Type of Inspection: M&vim Ft nit Addres/2 ,c,, Date Called: 03 / Special Instructions: Date Wanted: p 136 1— �le a.m. p.m. Requester: Phone No: • pproved per applicable codes. �J Corrections required prior to approval. COMMENTS: * td CoL //zo/zy raer pippv&,/-&O REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. eCC INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0._ CITY OF TUKWILA BUILDING DIVISION MO- 0202- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: t wt IRSt 4 PtDD moi Type of Inspection: /yrG iyi /ti 4 -,0 -L -- Address: /1203 -77714— AVZ 8, Date Called: )64 eol fL.4oR f QST ( 3ir/l-4i./6- Special Instructions: Date Wanted: `J' —Z7—! a a.m, p.m. Requester: (e • wire now 71 P P/P'' ,tkrT�G vd' Phone No: 'THIS r4tfl mo -r 8x /3- CavwPLi fm5f w ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Z // Veltlr Pce rr IN wtPL j/ 19 f rulk',Ds CoAiver iW f 4" 5&/'LID . to /11* Aix: R 64/4 -Ls 7-1-1,9-7- fl /007— ,e/fit/77- 2. No IDvC-t)oRIl /1/.5741,LAO 7z5 Rk7L 4t/ 4/A )64 eol fL.4oR f QST ( 3ir/l-4i./6- 3' fui tJi m-iis' Ama 71, d3C iferre545La i. g¢FL/(, n/R /U /-M o$- -p/a zx 9-7-/A006-14 Ia;p-L L , 6. D (' Doc -i PULL cqc ijr i ,tldp5 (e • wire now 71 P P/P'' ,tkrT�G vd' 01/T-51 PA 'THIS r4tfl mo -r 8x /3- CavwPLi fm5f w Inspector: ef6 Date: 7.9:7-46 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. CITY OF TUK Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 E-mail: tukplan@ci.tukwila.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION 01711•0 PERMIT PERMIT NO: M h -03)02 - STATE OF WASHINGTON) ) ss. COUNTY OF KING ) Yom- _ U1n , states as follows: [p ease print name] h- 01119 11-101 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirem_en.t of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number \ 3, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. .��„`„E Rip,' °1tt, 0 = .1r 4o1 A JQ . 'PS1, N i so -1' S!'OUB\' ® = N,,i ti~ -- IN,.. 'is �S�ttt10FWP�.'111111‘NN OTA RY PU / t LI in an for the State of Washington Owner/Owner's Ag t* Signed and sworn to before me this day of iV !I , 20l6 . Residing at Name as commissioned: , Cotlnty My commission expires: 1Y 04\ 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in-kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. * Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions.