Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M17-0063 - MUSEUM OF FLIGHT - DUCTLESS SPLIT HEAT PUMP SYSTEM
MUSEUM OF FLIGHT 9404 E MARGINAL WAY S M17-0063 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3324049019 Permit Number: 9404 E MARGINAL WAY S Issue Date: Permit Expires On: Project Name: MUSEUM OF FLIGHT M17-0063 5/22/2017 11/18/2017 Owner: Name: Address: MUSEUM OF FLIGHT FOUNDATION 9404 EAST MARGINAL WY S , SEATTLE, WA, 98108 Contact Person: Name: TED HUNT Address: Contractor: Name: Address: License No: Lender: Name: Address: 6426 18 ST E , TACOMA, WA, 98424 Phone: (253) 307-2835 MECHANICAL & CONTROL SERVICES Phone: (253) 926-9777 INC 6426 18TH ST E , FIFE, WA, 98424 MECHACS962BT Expiration Date: 2/26/2018 !/I DESCRIPTION OF WORK: INSTALL (1) 2 -TON MITSUBISHI DUCTLESS SPLIT HEAT PUMP SYSTEM FOR ELEVATOR MACHINE ROOM. INCLUDES INDOOR UNIT WILL MOUNT ON WALL OF THE MACHINE ROOM AND THERMOSTAT AND OUTDOOR UNIT WILL MOUNT ON GROUND PRE -CAST HOUSEKEEPING PAD LOCATED AT THE NORTH EXTERIOR END OF THE BUILDING. NEW INSULATED REFRIGERATION PIPING TO OUTDOOR AND INDOOR UNITS. INSTALL CONDENSATE PUMP AND PIPING. Valuation of Work: $14,943.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $409.30 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the c• • ons attached to this permit. Signature: Date: 5/9g /69c..)/-7 Print Name: [ ,e_d U� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 2: ***MECHANICAL PERMIT CONDITIONS*** 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWIJv_ . Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M Project No. Date Application Accepted: ; Ii 11 1 Date Application Expires: ((I' C I 1 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 9404 East Marginal Way S 98108 Tenant Name: Museum of Flight PROPERTY OWNER Name: Ted Hunt Name: Museum of Flight Foundation City: Tacoma State: WA Zip: 98424 Address: 9404 East Marginal Way S Email: tedh@groupmcs.com City: Seattle State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Ted Hunt Address: 6426 18th Street East City: Tacoma State: WA Zip: 98424 Phone: (253) 307-2835 Fax: (253) 926-9222 Email: tedh@groupmcs.com King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ® .. No 3324049019 MECHANICAL CONTRACTOR INFORMATION Company Name: Mechanical & Control Services, Inc. Address: 6426 18th Street East City: Tacoma State: WA Zip: 98424 Phone:(253) 926-9777 Fax: (253) 926-9222 Contr Reg No.: MECHACS962BT Exp Date: 02/26/2018 Tukwila Business License No.: BUS -0997334 Valuation of project (contractor's bid price): $ 14,943 Describe the scope of work in detail: Install (1) 2 -ton Mitsubishi ductless split heat pump system for Elevator Machine Room. Includes indoor unit will mount on wall of the machine room and thermostat and outdoor unit will mount on ground pre -cast housekeeping pad located at the north exterior end of building. New insulated refrigeration piping to outdoor and indoor units. Install condensate pump and piping. 1.L Residential: New ❑ Replacement 0 Commercial: New ® Replacement 0 Fuel Type; Electric Gas Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page I of 2 Jr. Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 1 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 1 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 1 Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 1 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDINGD AGENT: Signature------ Print Name: Ted Hu t Mailing Address: 6426 18th Street East Date: Day Telephone: (253) 307-2835 Tacoma WA 98424 City 14:\Applications \Forms -Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R0485 DESCRIPTIONS I PermitTRAK ACCOUNT QUANTITY .. PAID $409.30 M17-0063 Address: 9404E MARGINAL WAY S Apn: 3324049019 $409.30 Credit Card Fee $11.92 Credit Card Fee R000.369.908.00.00 0.00 $11.92 MECHANICAL $382.10 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $272.53 PLAN CHECK FEE R000.322.102.00.00 0.00 $76.42 TECHNOLOGY FEE $15.28 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1148.5 R000.322.900.04.00 0.00 $15.28 $409.30 Date Paid: Monday, May 15, 2017 Paid By: TED HUNT Pay Method: CREDIT CARD 115171 Printed: Monday, May 15, 2017 9:18 AM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit r4 o66:3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /41.9-C6eJM C'/ (444T Type of Inspection: 1 r1 )4#A)4(4L b.)4/_. Address: A 1 Zie.) ( 144 eo-/AirAL tJ _ Date Called: Special Instructions: (r) .2— i'e spur EL.EV/W R ii1RC)f itiE Rc IM Date Wanted" 6, l7 m. Requester: Craar l R L b Phone No: p /� 14M-' e{78• ©gqr Approved per applicable codes. Corrections required prior to approval. COMMENTS: b./G /ngc% /01-2'&W 1 X/ t Inspector: Date: 6- I -17 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 mI-7- 006 3 Project:Type fl1IA670M Lir /6117-='' of Inspection: , r ► -,uPt/ai_ )AL. e /t'er,7- i 56,A/ t,t)A s /✓fir Ip4'97? Address:.Date '94/04 f 41/4e6dx4.4. & S Called: Special Instructions: 0) Z —Tema 7w1 Ni SPLIT FD i-0.4 /-al& rAP►CNf1NP iZuSY 4 Date Wanted: 6 /1 / 7 m ,,'' Requester. CPQ )6 Zei,rtibiriAt6 Phone No: ?c4 -- `76/6- 72oi 0 Approved per applicable codes. ‘IZCorrections required prior to approval. COMMENTS: e /t'er,7- i 56,A/ t,t)A s /✓fir Ip4'97? ,e) % 1-//O e%4/ , z`✓9 ./l%l3/: i Zf Y:k/,?f'' 7 ;, Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection: SEPAP!ATE PERMIT REQUIRED FOR: Mechanical Ciectncai Itumbfng Idas Pimp City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope . of work without prior approval of Tu.vvila Building Division. 1 t O"l : P:••: a ns .ipl require a new plan submittal and may i :;lude additional plan review fees. FILE COPY Permit No. Ni l 7 - 000 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved F3id Copy and conditions ' = cknowledged: By: Date: REVIEWED FOR CODE COMPLIANC APPROVED MAY 162011 tztCity of Tukwila City of Tukwila BUILDING DIVISION BUILDING DIVISION Vl t7OO(o3 M -S RIES SUBMITTAL DA►T'A° 24,000 MSZ-GL24NA-U1 BTU/H WALL -MOUNTED C'3 MUZ-GL24NA-U1 MITSUBISHI ELECTRIC JobNa ne: Cooling' Btu/h / W -� r- Btu/h/ W System Reference: Refrigerant Piping Flared) if.' = Date: it t Indoor Unit MSZ-GL24NA-U1 Wireless Remote Controller ACCESSORIES: Indoor Unit •„y Outdoor Unit MUZ-GL24NA-U1 ❑ Condensate Pump (BlueDiamond X87-711/721; 115/230V) ❑ Condensate Pump (Sauermann S130-115/230; 115/230V) ❑ Anti -Allergy Enzyme Filter (MAC-408FT E) o Drain Pan Level Sensor (DPLS2) Outdoor Unit o Outdoor Mounting Pad (ULTRILITEI) o Drain Pan Heater (MAC-642BH-U) o 3-1/4" Mounting Base [Pair] (DSD -400P) ❑ Drain Pan Socket (MAC -851 DS) o Air Outlet Guide (MAC-886SG-E) ❑ Wall Mounting Bracket (QSWB2000M-1) Controls 208 / 230V, 1 -Phase, 60 Hz Mow Circ it Ampacity Indoor / Outdoor A 1 /17.1 Blower Motor (ECM) Blower Motor Output F.L.A. 0.76 w 55 SHF / Moisture Removal 0.75 / 5.1 pt./h REVIEWED FOR CODE COMPLIANCE APPROVED MAY 16 2017 City of Tukwila ❑ Wireless Controller (MHK1) �1� ❑ Wired Remote Controller PAR-32MAA (Requ'reBM83 f DIVISION o Wireless Interface for kumo doud'"" (PAC -U1 o Thermostat Interface (PAC-US444CN-1) Field Drainpipe Size O.D. In.(mm) 5/8 (15) O.tdoor Compressor DC INVERTER -driven Twin Rotary Fan Motor (ECM) F.L.A. 0.93 SPECIFICATIONS: Rated Conditions Capacity° •r Cooling' Btu/h / W 22,400 / 1,800 Heating at 47° F2 Btu/h/ W 27,600 / 2,340 EDM T rI_rJITLi:a Refrigerant Piping Flared) Liquid (High Pressure) =WA INIIMHEM Gapacity ' r • Cooling' Btum 8,200 31,400 Heating at 47° F2 Btu/h 7,500 36,900 Heating at 17° F3 Btu/h - 24,600 Heating at 5° F' Btu/h - 21,160 ' Cooling 1 Indoor. 80° F(27° C)DB 67° F(19° C)WB; Outdoor. 95° F(35° C)DB / 75° F(24° C)WB' ' Heating at 47°F 1 Indoor. 70° F (21° C)DB / 60° F (16° C)WB; Outdoor. 47° F 8° C)DB / 43° F (6° C)WB' ' Heating at 17° F I Indoor. 70° F(2 ° C)DB / 60° F(16° C)WB; Outdoor. 17° F(-8° C)DB / 15° F(-9° C)WB' ' Heating at 5° F !Indoor 70° F (21 C)DB / 60° F(16° C)WB; Outdoor. 5° F(-15° C) DB / 5° F(-15° C)WB . Rating Conditions perAHRI Standard: Operating Gori • itons Indoor Villiah( NW Cooling2 90° F (32° C) DB / 67° F (19° C) DB Heating 80° F (27° C) DB / 70° F (21° C) DB Operating Gonditons Outdoor Intake Air 1` •)((Ill�4(] Ii1j) Coolings 115 F (46° C) DB / 14° F (-10° C) DB Heating 75° F (24° C) DB / -4° F (-20° C) DB" "Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. System cuts out at -9° F (-27° C) to avoid thermistor error and automatically restarts at -4° F (-20° C). SEER/HSPF Ratings 20.5/10.0 COP at 47° F / 17° F 3.46 / 2.65 Yes ENERGY STAR products are third -party certified by an EPA -recognized Certification Body. Specifications are subject to change without notice. Indoor (Cooling) DRY WET Indoor (Heating) DRY Outdoor CFM 388-469-544-628-738 347-420-487-562-661 388-469-544-628-738 1769/1701 aomialPti;fflocilliam3CM.W. .04). Ektco Olt Indoor Cooling Outdoor Heating Cooling Heating dB(A) 34-41-45-49-53 32-41-45-49-52 55 55 Dimensions Indoor (H x W x D) Outdoor (H x W x D) In.(mm) 12-13/16 x 43-5/16 x 9-3/8 (325 x 1,100 x 238) 34-5/8 x 33-1/16 x 13 (880 x 840 x 330) Weight Indoor Outdoor Lbs.(kg) 37 (17) 119 (54) Indoor Munsell 1.Ulr 9.1 / 0.1 u tNvY I L/4 Outdoor Munsell No. MA8 /111 11 11 2017 a f `Refrigerant R410A; 4 Ib. 3 oz. EDM T rI_rJITLi:a Refrigerant Piping Flared) Liquid (High Pressure) In.(mm) 3/8 (9.52) Gas (Low Pressure) 5/8 (15.88) Max. Total Refrigerant Pipe Length (Height Diff.) Ft. (m) 50 (15) Max. Total Refrigerant Pipe Length (Length.) 100 (30) OMMr, Mitsubishi Electric US, Inc. MSZ-GL24NA-U1 2-5/16 3/4 51 O DIMENSIONS: MSZ-GL24NA-U1 & MUZ-GL24NA-U1 1/1641 oblong 9414 Insfollolion elate Unit: in. (mm) 1/16x13/16 Oblo41 601 0.1 MUZ-GL24NA-U1 1 I I_ 2-9/16 2-9/16 REQUIRED SPACE I_1.3/16 '1 20 in. (500 mm) or more when front and sides of the unit are Gear holes 13/32X13/16 Air in I1sfallolios elate \ I' Pin 111011111.0gain h I Air out 2-9/161111111 4.1/8 I 6-5/16 e, Infulol ion 2 0.0 0. Liquid line .318 11-11116 Mated Connection 13181 ' Gas line 1112 16.15116 (01 Drain Aofe Innu101ion H-1/8 me( le tlXI ti,1 '2 When any 2 sides of left, right and rear of the unit are clear Service panel Liquid refrigerant pipe joint Refrigerant pipe (flared) 01/4 (GL18) Refrigerant pipe (flared) 0 3/8 (GL24) FORM# MSZ-GL24NA-U1 / MUZ-GL24NA-U1 - 201611 Specifications are subject to change without notice. Gas refrigerant pipe joint Refrigerant pipe (Bared) 01/2 (GL18) Refri • erant • i • e (flared) 0 5/8 (GL24) D FOR CODE COMPLIANCE APPROVED MAQlnitlir602917 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY l 5 2017 PERMIT CENTER Art MLEClFgC � COOLING & HEATING 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Intertek 1411 000Electric US, Inc. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0063 DATE: 05/15/17 PROJECT NAME: MUSEUM OF FLIGHT SITE ADDRESS: 9404 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # - after Permit Issued DEPARTMENTS: Building Division Public Works ❑ ,4ik AVA- 5-1Vr.7 Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 05/16/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 06/13/17 U Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 MECHANICAL & CONTROL SRVr'S INC Home Espanol Contact Safety & Health Claims & Insurance 41) Washington State Department of Labor & industries Search L&I Page 1 of 3 A -Z Index help My L&I Workplace Rights Trades & Licensing MECHANICAL & CONTROL SRVCS INC Owner or tradesperson Principals Hull, Travis Edward, PRESIDENT Hunt, Ted Lamond, VICE PRESIDENT HULL, ANGELA DAWN, SECRETARY GROVER, HAROLD, VICE PRESIDENT (End: 02/26/2010) DICKSON, PAUL, TREASURER (End: 02/26/2010) Doing business as MECHANICAL & CONTROL SRVCS INC WA UBI No. 602 338 440 6426 18th St E FIFE, WA 98424 253-926-9777 PIERCE County Business type Corporation Governing persons ANGELA DAWN HULL TRAVIS EDWARD HULL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MECHACS962BT Effective — expiration 01/30/2004— 02/26/2018 Bond American Contractors Indem CO Bond account no. 100239439 $12,000.00 Received by L&I Effective date 02/10/2014 02/06/2014 Expiration date Until Canceled Bond history Insurance Continental Western Ins Co Policy no. 6023856626 $1,000,000.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602338440&LIC=MECHACS962BT&SAW= 5/22/2017 MECHANICAL & CONTROL SRVCS INC Received by L&I Effective date 01/20/2017 01/23/2016 Expiration date 01/23/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 539,805-00 Account is current. Doing business as MECHANICAL & CONTROL SERVICES Estimated workers reported Quarter 1 of Year 2017 "21 to 30 Workers" L&I account representative T5 / MELISSA VEST (360)902-5613 - Email: VESM235@Ini.wa.gov Track this contractor Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 05/22/2013 Inspection no. 316579655 Location 13570 Bell -Red Rd Bellevue, WA 98005 Violations Inspection results date 02/26/2013 Inspection no. 316582154 Location 30 S Wenatchee Ave Wenatchee, WA 98801 Violations Inspection results date 02/21/2013 Inspection no. 316578681 Location 13570 Bel -Red Rd Bellevue, WA 98005 No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=60233 8440&LIC=MECHACS962BT&SAW= 5/22/2017