Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG17-0012 - COSTCO / OPTICAL CENTER - WATER HEATER AND SINK
COSTCO - OPTICAL CENTER 400 COSTCO DR 100 PG17-0012 Parcel No:. Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 2523049063 400 COSTCO DR 100 Project Name: COSTCO - OPTICAL CENTER Permit Number: PG17-0012 Issue Date: 1/30/2017 Permit Expires On: 7/29/2017 Owner: Name: Address: Contact Person: Name: COSTCO WHOLESALE CORPORATIO 999 LAKE DR PROPERTY TAX DEPT 006, ISSAQUAH, WA, 98027 KAYLENE NELSON Address: 1221 SECOND AVE N , KENT, WA, 98032 Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AVE N , KENT, WA, 98032- 2945 License No: HERMACLOO5BJ Lender: Name: Address: II I Phone: (253) 359-7147 Phone: (206) 575-9700 Expiration Date: 8/25/2018 DESCRIPTION OF WORK: PROVIDE AND INSTALL (1) WATER HEATER, INSTALL (1) OPTICAL SINK Valuation of Work: $4,500.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $152.29 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: ffd04 i�% Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development , : r It and agree to the conditions attached to this permit. Signature: Print Name: (LH (Junk iv -e Date: 1 S6 / 17 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Applicant shall submit executed Non -Residential Sewer Use Certification form to Public Works before permit issue. 2: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 3: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 4: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 5: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 6: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 7: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 8: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 9: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 10: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 11: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 12: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 14: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 15: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKW:. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. p617-001.), Project No. Date Application Accepted: i o —3`I 7 Date Application Expires: —7 se)--' 7 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION, Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2523049063 Site Address: 400 Costco Drive Tukwila, WA 98188 Suite Number: Tenant Name: Costco Tukwila Optical Center PROPERTY OWNER Name: Kaylene Nelson Address: 1221 2nd Avenue N Name: Costco Wholesale Phone: (253) 359-7147 . Fax: Email: KAYLENE.NELSON@HERMANSON.CO r Address: 999 Lake Drive City: Issaquah State: WA Zip: 98027 CONTACT PERSON — person receiving all project communication Name: Kaylene Nelson Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 . Fax: Email: KAYLENE.NELSON@HERMANSON.CO r Floor: New Tenant: ❑ Yes ® .. No PLUMBING CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Contr Reg No.: HERMACLOO5BJ Exp Date: 08/25/2018 Tukwila Business License No.: BUS -0994464 Valuation of Project (contractor's bid price): $ 4,500 Scope of Work (please provide detailed information): Provide and install (1) Water Heater, Install (1) Optical Sink. Building Use (per Int'I Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-I I.docs Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or b_s piping outlets being installed and the quantity Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks 1 Rain water system — per drain (inside building) 1 Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty, Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND i AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNAGENT: Signature: Print Name: Kaylene Nelson Mailing Address: 1221 2nd Avenue N H:\Applications\Forms-Applications On Line\201 I Applications \Plumbing Permit Application Revised 5-9-1 I.docx Revised: August 2011 bh Day Telephone: e1 t City Date: 01/23/2017 (253) 359-7147 WA 98032 Statc Zip Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $424.33 M17-0011 Address: 400 COSTCO DR 100 Apn: 2523049063 $272.04 Credit Card Fee $7.92 Credit Card Fee R000.369.908.00.00 0.00 $7.92 MECHANICAL , $253.96 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $170.02 PLAN CHECK FEE R000.322.102.00.00 0.00 $50.79 TECHNOLOGY FEE $10.16 TECHNOLOGY FEE R000.322.900.04.00 0.00 $10.16 PG17-0012 Address: 400 COSTCO DR 100 Apn: 2523049063 $152.29 Credit Card Fee $4.44 Credit Card Fee R000.369.908.00.00 0.00 $4.44 PLUMBING $142.16 PERMIT FEE R000.322.100.00.00 0.00 $80.58 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $28.43 TECHNOLOGY FEE $5.69 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R10542 0.00 $5.69 $424.33 Date Paid: Monday, January 23, 2017 Paid By: KAYLENE NELSON Pay Method: CREDIT CARD 808722 Printed: Monday, January 23, 2017 3:32 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request line (206) 438-9350 P6-17-6 I Z Proj ct: (s76 -Ciont4L ecii7DX Type of Inspection: PIAL n413iNG FINAL. Address: «AA e'D.5 Zo k2. Date Called: Special Instructions: Date Wanted: _ l 7 ` J (aa. m Requester: Kiwr KVLJL-- FjLL Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: ?-s Date: -I 7-/ 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. o INSPECTION NO. INSPECTION RECORD Retain a copy with permit Vii? -6012 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Proj ct: ��y S", COSTCD CJncAL thurne T e of Inspection: 1 7 i- bur it mo i' Address: 4e0 agieo biz Date Called: 1 Special Instructions: AOq� eALL Date Wante /f 2 1 7 m. Re uester- Phone No: 7CX_Sl-2- 579g'' Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: IM it Inspector: vitui- Date f /7 " I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. it PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0012 DATE: 01/23/17 PROJECT NAME: COSTCO - OPTICAL CENTER SITE ADDRESS: 400 COSTCO DR X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division l &NS 4 -WC lir 3 Public Works Fire Prevention Structural Planning Division ri Permit Coordinator v PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/24/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/21/17 Approved Corrections Required n (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) Fl Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: — Departments Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: )2/18/2013 HERMANSON COMPANY LLP Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 3 A -Z Index Help My L.&I Workplace Rights Trades & Licensing HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No. 602 004 844 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County Business type Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HERMACLOO5BJ Effective — expiration 01/11/2000— 08/25/2018 Bond WESTERN SURETY CO Bond account no. 929381801 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 1/30/2017 HERMANSON COMPANY LLP Insurance Valley Forge Ins Co $1,000,000.00 Policy no. 6043050846 Received by L&I Effective date 08/15/2016 08/21/2016 Expiration date 08/21/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 409,648-01 Doing business as HERMANSON COMPANY LLP Estimated workers reported Quarter 3 of Year 2016 "Greater than 100 Workers" L&I account representative T1 / NIKKI BUTLER (360)902-4918 - Email: BUTQ235@Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 02/23/2016 Inspection no. 317939295 Location 15580 NE 31st St. Redmond, WA 98052 No violations Inspection results date 05/21/2015 Inspection no. 317935231 Location 4480 154th PI NE Redmond, WA 98052 No violations Inspection results date 12/10/2014 Inspection no. 317424935 Location 21601 76th Ave W. Edmonds, WA 98026 No violations Inspection results date 05/17/2013 Violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 1/30/2017 CONNECT NEW 1/ GAS W/PRV TO EXISTING GAS ON ROOF. r Costco — K:\2015\300-309\15-302 G LL� REMOVE EXISTING UNIT & INSTALL NEW UNIT PER SCHEDULE. SEE DETAIL AREA OF WORK. O 1> Li] _TR PARTIAL FLOOR PLAN SCALE: 1/16" = 1'-0" THERMOSTAT RELOCATE BRANCH DUCT AS SHOWN. PROVIDE NEW DIFFUSER. x 8/8 CD -4 100 CFM (E) IVD (E)8"0 24/1 RG 6 CD -4 '.0 44/24 RG (5) 24/12 60 RG 0/10 CD -4 150 ;FM 18 X 18 X 10' 10" 8 10 E)8" 0 D-4 CFM 10"0 1 0/10 CD -4 250 CFM 10/10 CD -4 250 CFM FIELD VERIFY SIZE AND REUSE EXISTING LOCATION OF SUPPLY OPENING IN AND RETURN DUCTING. SUPPLY DUCT EXISTING WATER HEATER UNDER SINK TO REMAIN ) DEMO EXISTING SUPPLY DUCT PROVIDE NEW 10" SUPPLY DUCT. OPTICAL CENTER HVAC PLAN SCALE: 1/4" = 1'-0" CONNECT 1/2" H&CW TO THE NEW SINK. 1VD 10"s6 NEW 10" DUCT FROM EXISTING AS SEE FIT FOR NEW SUPPLY DIFFUSER. MAINTAIN DUCT SIZE. PROVIDE 1/2" H & CW SEE DETAIL CONNECT NEW 3/4" CW TO EXISTING 3/4" APPROX. HERE. FIELD VERIFY SIZE AND LOCATION. o� -1 X 10" MAX DEVELOPED LENGTH (FEET) 100 PIPE SIZE ( UPC) r L.� 141 18 X 10" 1" 98 (E)8"0 VD _ 1,141 185 Fill •r• (E) 380 8/8 CD -4 100 CFM 6 CD -4 '.0 44/24 RG (5) 24/12 60 RG 0/10 CD -4 150 ;FM 18 X 18 X 10' 10" 8 10 E)8" 0 D-4 CFM 10"0 1 0/10 CD -4 250 CFM 10/10 CD -4 250 CFM FIELD VERIFY SIZE AND REUSE EXISTING LOCATION OF SUPPLY OPENING IN AND RETURN DUCTING. SUPPLY DUCT EXISTING WATER HEATER UNDER SINK TO REMAIN ) DEMO EXISTING SUPPLY DUCT PROVIDE NEW 10" SUPPLY DUCT. OPTICAL CENTER HVAC PLAN SCALE: 1/4" = 1'-0" CONNECT 1/2" H&CW TO THE NEW SINK. 1VD 10"s6 NEW 10" DUCT FROM EXISTING AS SEE FIT FOR NEW SUPPLY DIFFUSER. MAINTAIN DUCT SIZE. PROVIDE 1/2" H & CW SEE DETAIL CONNECT NEW 3/4" CW TO EXISTING 3/4" APPROX. HERE. FIELD VERIFY SIZE AND LOCATION. OPTICAL CENTER PLUMBING PLAN SCALE: 1/4" = 1'-0" PIPING SYSTEMS THE FOLLOWING NOTES APPLY TO ALL PLUMBING PLANS. 1. APPUCABLE PLUMBING CODE: 2012 UPC 2. ALL WASTE PIPING, CONDENSATE PIPING & STORM DRAIN PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. 3. SURFACE MOUNTED PIPING WILL NOT BE ACCEPTABLE IN FINISHED ROOMS OR COOLERS. PIPING AND CONDUIT OF ALL TYPES SHALL BE CONCEALED WITHIN WALLS, FLOORS, CEILINGS (INCLUDING CONDENSATE DRAIN UNES, WATER HEATER PRESSURE REUEF UNES AND SODA LINES). 4. INSULATE ALL INTERIOR PIPING; STORM DRAIN, HOT, COLD, RECIRC, AND CONDENSATE PER SPECIFICATION SECTION 22 07 00. 5. PIPING IN ROOF TRUSS SPACE TO BE RUN PERPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS, FOR PASSING BELOW SOUD GIRDERS MOUNT PIPING 6" MAXIMUM FROM BOTTOM OF GIRDER. DO NOT BLOCK UGHTING & SKYUGHTS. GENERAL MECHANICAL NOTES THE FOLLOWING NOTES APPLY TO ENTIRE PLAN AS APPLICABLE.. 1. M.C. SHALL ENSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON PLAN ON THE INSIDE & OUT OF THE BUILDING. THIS INCLUDES HVAC UNITS & EXHAUST FANS. LABELS SHOULD BE IN 6" BLOCK LETTERING IN BLACK COLOR AND LOCATED WHERE EASILY VISIBLE FROM THE ROOF HATCH. 2. MAINTAIN A MINIMUM OF 10'-0" BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. 3. COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OR PANELS. 4. DIMENSIONS ARE TO COLUMN LINES. 5. APPLICABLE BUILDING CODE 2015 IBC APPLICABLE MECHANICAL CODE: 2015 IMC APPLICABLE ENERGY CODE: 2015 WASHINGTON STATE ENERGY CODE 6. PROVIDE TIE DOWN FOR ALL FLUES & VENTS OF 3' OR TALLER. 7. FIELD VERIFY EXISTING FIRE SPRINKLERS AND DUCT DETECTORS. REINSTALL AND RECONNECT DUCT DETECTORS OR REPLACE WITH EQUAL. 8. ALL CONDENSATE PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. 9. RUN PIPING IN ROOF TRUSS SPACE PERPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS, FOR PASSING BELOW SOUD GIRDERS MOUNT PIPING 6" MAXIMUM FROM BOTTOM OF GIRDER. DO NOT BLOCK UGHTING & SKYLIGHTS. MECHANICAL PLAN NOTES SEE BUBBLE ON PLAN FOR SPECIFIC REFERENCE. 2O NEW AC UNIT ON ADAPTOR CURB. REPLACE EXISTING AC UNIT WITH NEW AC UNIT. INSTALL ADAPTOR ON EXISTING CURB AND NEW AC UNIT ON ADAPTOR. CONNECT GAS AND CONDENSATE WHERE APPLICABLE. FIELD VERIFY SIZE, LOCATION AND DIMENSIONS OF EXISTING AC UNIT AND CURB. SCRAPE EXISTING GASKET AND ADHESIVE FROM CURB AND REPLACE WITH NEW NEOPRENE GASKET FOR BOTH ADAPTER CURB AND NEW UNIT. ADAPTOR CURB TO BE PRE-ENGINEERED BY THYBAR OR EQUIVALENT. FOR COORDINATION WITH THYBAR CONTACT BILL MARZEC (775-343-0600) 0 THYBAR TO ORDER ADAPTOR CURBS. EXISTING STAINLESS STEEL CURBS TO BE EQUIPPED WITH STAINLESS STEEL ADAPTOR CURBS. G.C. TO SUBMIT STAMPED DRAWING FOR ADAPTOR CURB. SUBMITTAL TO INCLUDE CONNECTIONS BETWEEN EXISTING CURB & ADAPTOR CURB; AND CONNECTION BETWEEN ADAPTOR CURB & NEW AC UNIT; AND ADAPTOR CURB WEIGHT. FC0o NEW 1 1/2" VENT. CONNECT TO EXISTING VENT APPROX HERE. FIELD VERIFY LOCATION. HVAC LEGEND k 2244/48 k L. TV k k iNN1 -c- CONT. TYP. CFM DB DG WB MBH ESP RG CD RA SA CO VD MBS M.0 G.0 AIR DUCT - FIRST # IS SIDE SHOWN FLEXIBLE DUCT CONNECTION TURNING VANE SUPPLY DUCT UP RETURN DUCT UP SUPPLY DUCT DOWN RETURN DUCT DOWN AIR VOLUME DAMPER CEILING DIFFUSER SQUARE TO ROUND DUCT TRANSITION CONDENSATE DRAIN AIR CONDITIONER #1 THERMOSTAT CONTINUATION TYPICAL CUBIC FEET PER MINUTE DRY BULB TEMPERATURE DOOR GRILLE WET BULB TEMPERATURE 1,000 BRITISH THERMAL UNITS/HR. EXTERNAL STATIC PRESSURE RETURN GRILLE CEILING DIFFUSER RETURN AIR SUPPLY AIR CLEAN OUT VOLUME DAMPER METAL BUILDING SUPPLIER MECHANICAL CONTRACTOR GENERAL CONTRACTOR CONNECT NEW 2" WASTE LINE TO EXISTING LINE LOCATED ABOVE FLOOR AND BEHIND WALL APPROX. HERE. FIELD VERIFY SIZE, PLUMBISG LEGEND A C G V �i► C-� A.F.F. A.H.J. B.F.F. CO CONT. CW FCO G.0 G.V H&CW HW IN. WC M.0 PSI SCO S.S. TYP. U VTR W. WCO WASTE/SANITARY SEWER VENT COLD WATER HOT WATER HOT WATER CIRCULATION AIR CONDENSATE DRAIN GAS GAS COCK UNION VALVE - GATE VALVE - PRESSURE REDUCING (PRV) CAP OFF ABOVE FINISH FLOOR AUTHORITY HAVING JURISDICTION BELOW FINISH FLOOR CLEAN OUT CONTINUATION COLD WATER FLOOR CLEAN OUT GENERAL CONTRACTOR GATE VALVE HOT & COLD WATER HOT WATER INCHES OF WATER COLUMN MECHANICAL CONTRACTOR POUNDS PER SQUARE INCH SURFACE CLEAN OUT SANITARY SEWER TYPICAL UNION VENT THRU ROOF WASTE WALL CLEAN OUT GAS CALCULATIONS Existing Total Existing load 7,690,000 New Loads AC -11 60,000 TOTAL GAS LOAD 7,750,000 X" GAS LINE SERVICE IS REQUIRED @ 3 PSI. GAS SIZE CHART PRESSURE IN WC 7 (1-49 MAX DEVELOPED LENGTH (FEET) 100 PIPE SIZE ( UPC) MAX LOAD (MBH) (-OES 141 47 3/4" 1" 98 1" 1,141 185 1-1/4" 2" 380 1-1/2" 5,245 570 2" 4" 1,098 2-1/2" 55,407 1,750 3" PROVIDE ONE OF FOLLOWING 3,093 4" SENSUS MODEL 6,309 6" ORIFICE - 3/8" 18,483 8" MAXITROL MODEL: 37,976 PIPE SIZE - 3/4" OR 1" FOR GAS LOAD UP TO 340 MBH 325-7AL21OD PIPE SIZE 1-1/4" OR 1-1/2" FOR GAS LOAD BETWEEN 340 MBH AND 1000 MBH rif: BE RATED FOR 5 PSI. LE\ {I 'I 1-1/2" (E)3/4" CW --[- 24'x! (E)3/4" CW % ( II G G G (5)3" GAS G 0 [ G I.J G 0 Ly 0 III 1-1/2" VT MI U �- . El) 0- 9- D 6) (-EMILIntlir_-_- (:::)" D - OPTICAL CENTER PLUMBING PLAN SCALE: 1/4" = 1'-0" PIPING SYSTEMS THE FOLLOWING NOTES APPLY TO ALL PLUMBING PLANS. 1. APPUCABLE PLUMBING CODE: 2012 UPC 2. ALL WASTE PIPING, CONDENSATE PIPING & STORM DRAIN PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. 3. SURFACE MOUNTED PIPING WILL NOT BE ACCEPTABLE IN FINISHED ROOMS OR COOLERS. PIPING AND CONDUIT OF ALL TYPES SHALL BE CONCEALED WITHIN WALLS, FLOORS, CEILINGS (INCLUDING CONDENSATE DRAIN UNES, WATER HEATER PRESSURE REUEF UNES AND SODA LINES). 4. INSULATE ALL INTERIOR PIPING; STORM DRAIN, HOT, COLD, RECIRC, AND CONDENSATE PER SPECIFICATION SECTION 22 07 00. 5. PIPING IN ROOF TRUSS SPACE TO BE RUN PERPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS, FOR PASSING BELOW SOUD GIRDERS MOUNT PIPING 6" MAXIMUM FROM BOTTOM OF GIRDER. DO NOT BLOCK UGHTING & SKYUGHTS. GENERAL MECHANICAL NOTES THE FOLLOWING NOTES APPLY TO ENTIRE PLAN AS APPLICABLE.. 1. M.C. SHALL ENSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON PLAN ON THE INSIDE & OUT OF THE BUILDING. THIS INCLUDES HVAC UNITS & EXHAUST FANS. LABELS SHOULD BE IN 6" BLOCK LETTERING IN BLACK COLOR AND LOCATED WHERE EASILY VISIBLE FROM THE ROOF HATCH. 2. MAINTAIN A MINIMUM OF 10'-0" BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. 3. COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OR PANELS. 4. DIMENSIONS ARE TO COLUMN LINES. 5. APPLICABLE BUILDING CODE 2015 IBC APPLICABLE MECHANICAL CODE: 2015 IMC APPLICABLE ENERGY CODE: 2015 WASHINGTON STATE ENERGY CODE 6. PROVIDE TIE DOWN FOR ALL FLUES & VENTS OF 3' OR TALLER. 7. FIELD VERIFY EXISTING FIRE SPRINKLERS AND DUCT DETECTORS. REINSTALL AND RECONNECT DUCT DETECTORS OR REPLACE WITH EQUAL. 8. ALL CONDENSATE PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. 9. RUN PIPING IN ROOF TRUSS SPACE PERPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS, FOR PASSING BELOW SOUD GIRDERS MOUNT PIPING 6" MAXIMUM FROM BOTTOM OF GIRDER. DO NOT BLOCK UGHTING & SKYLIGHTS. MECHANICAL PLAN NOTES SEE BUBBLE ON PLAN FOR SPECIFIC REFERENCE. 2O NEW AC UNIT ON ADAPTOR CURB. REPLACE EXISTING AC UNIT WITH NEW AC UNIT. INSTALL ADAPTOR ON EXISTING CURB AND NEW AC UNIT ON ADAPTOR. CONNECT GAS AND CONDENSATE WHERE APPLICABLE. FIELD VERIFY SIZE, LOCATION AND DIMENSIONS OF EXISTING AC UNIT AND CURB. SCRAPE EXISTING GASKET AND ADHESIVE FROM CURB AND REPLACE WITH NEW NEOPRENE GASKET FOR BOTH ADAPTER CURB AND NEW UNIT. ADAPTOR CURB TO BE PRE-ENGINEERED BY THYBAR OR EQUIVALENT. FOR COORDINATION WITH THYBAR CONTACT BILL MARZEC (775-343-0600) 0 THYBAR TO ORDER ADAPTOR CURBS. EXISTING STAINLESS STEEL CURBS TO BE EQUIPPED WITH STAINLESS STEEL ADAPTOR CURBS. G.C. TO SUBMIT STAMPED DRAWING FOR ADAPTOR CURB. SUBMITTAL TO INCLUDE CONNECTIONS BETWEEN EXISTING CURB & ADAPTOR CURB; AND CONNECTION BETWEEN ADAPTOR CURB & NEW AC UNIT; AND ADAPTOR CURB WEIGHT. FC0o NEW 1 1/2" VENT. CONNECT TO EXISTING VENT APPROX HERE. FIELD VERIFY LOCATION. HVAC LEGEND k 2244/48 k L. TV k k iNN1 -c- CONT. TYP. CFM DB DG WB MBH ESP RG CD RA SA CO VD MBS M.0 G.0 AIR DUCT - FIRST # IS SIDE SHOWN FLEXIBLE DUCT CONNECTION TURNING VANE SUPPLY DUCT UP RETURN DUCT UP SUPPLY DUCT DOWN RETURN DUCT DOWN AIR VOLUME DAMPER CEILING DIFFUSER SQUARE TO ROUND DUCT TRANSITION CONDENSATE DRAIN AIR CONDITIONER #1 THERMOSTAT CONTINUATION TYPICAL CUBIC FEET PER MINUTE DRY BULB TEMPERATURE DOOR GRILLE WET BULB TEMPERATURE 1,000 BRITISH THERMAL UNITS/HR. EXTERNAL STATIC PRESSURE RETURN GRILLE CEILING DIFFUSER RETURN AIR SUPPLY AIR CLEAN OUT VOLUME DAMPER METAL BUILDING SUPPLIER MECHANICAL CONTRACTOR GENERAL CONTRACTOR CONNECT NEW 2" WASTE LINE TO EXISTING LINE LOCATED ABOVE FLOOR AND BEHIND WALL APPROX. HERE. FIELD VERIFY SIZE, PLUMBISG LEGEND A C G V �i► C-� A.F.F. A.H.J. B.F.F. CO CONT. CW FCO G.0 G.V H&CW HW IN. WC M.0 PSI SCO S.S. TYP. U VTR W. WCO WASTE/SANITARY SEWER VENT COLD WATER HOT WATER HOT WATER CIRCULATION AIR CONDENSATE DRAIN GAS GAS COCK UNION VALVE - GATE VALVE - PRESSURE REDUCING (PRV) CAP OFF ABOVE FINISH FLOOR AUTHORITY HAVING JURISDICTION BELOW FINISH FLOOR CLEAN OUT CONTINUATION COLD WATER FLOOR CLEAN OUT GENERAL CONTRACTOR GATE VALVE HOT & COLD WATER HOT WATER INCHES OF WATER COLUMN MECHANICAL CONTRACTOR POUNDS PER SQUARE INCH SURFACE CLEAN OUT SANITARY SEWER TYPICAL UNION VENT THRU ROOF WASTE WALL CLEAN OUT GAS CALCULATIONS Existing Total Existing load 7,690,000 New Loads AC -11 60,000 TOTAL GAS LOAD 7,750,000 X" GAS LINE SERVICE IS REQUIRED @ 3 PSI. GAS SIZE CHART PRESSURE IN WC 7 PRESSURE DROP 0.5 MAX DEVELOPED LENGTH (FEET) 100 PIPE SIZE ( UPC) MAX LOAD (MBH) 1/2" 141 47 3/4" 1" 98 1" 1,141 185 1-1/4" 2" 380 1-1/2" 5,245 570 2" 4" 1,098 2-1/2" 55,407 1,750 3" PROVIDE ONE OF FOLLOWING 3,093 4" SENSUS MODEL 6,309 6" ORIFICE - 3/8" 18,483 8" MAXITROL MODEL: 37,976 (5)6" LOCATION, AND I.E. PRIOR TO WORK (q2,. MAX DEVELOPED LENGTH (FEET) 800 PIPE SIZE( UPC) MAX LOAD (MBH) 1/2" 141 3/4" — 1" 556 2" 1,141 1-1/2" 1,709 2" 3,291 2-1/2" 5,245 3" 9,273 4" 18,914 6" 55,407 8" 113,841 PROVIDE ONE OF FOLLOWING REGULATORS AT EACH PIECE OF EQUIPMENT SENSUS MODEL #496 PIPE SIZE - 3/4" OR 1" ORIFICE - 3/8" SPRING - GREEN FOR GAS LOAD UP TO 760 MBH MAXITROL MODEL: 325-5L600 PIPE SIZE - 3/4" OR 1" FOR GAS LOAD UP TO 340 MBH 325-7AL21OD PIPE SIZE 1-1/4" OR 1-1/2" FOR GAS LOAD BETWEEN 340 MBH AND 1000 MBH *ALL GAS PRESSURE REGULATORS TO BE RATED FOR 5 PSI. LE\ {I 'I 1-1/2" __ 1-1/2" VT MI U D 6) (:::)" D ni OPTICAL CENTER WASTE & VENT PLAN SCALE: 1/4" = 1'-0" GAS SIZE CHART PRESSURE PSI 2 PRESSURE DROP PSI TO 1.0 MAX DEVELOPED LENGTH (FEET) 800 PIPE SIZE( UPC) MAX LOAD (MBH) 1/2" 141 3/4" 295 1" 556 1-1/4" 1,141 1-1/2" 1,709 2" 3,291 2-1/2" 5,245 3" 9,273 4" 18,914 6" 55,407 8" 113,841 PROVIDE ONE OF FOLLOWING REGULATORS AT EACH PIECE OF EQUIPMENT SENSUS MODEL #496 PIPE SIZE - 3/4" OR 1" ORIFICE - 3/8" SPRING - GREEN FOR GAS LOAD UP TO 760 MBH MAXITROL MODEL: 325-5L600 PIPE SIZE - 3/4" OR 1" FOR GAS LOAD UP TO 340 MBH 325-7AL21OD PIPE SIZE 1-1/4" OR 1-1/2" FOR GAS LOAD BETWEEN 340 MBH AND 1000 MBH *ALL GAS PRESSURE REGULATORS TO BE RATED FOR 5 PSI. RECEIVED CITY OF TUKWILA JAN 2 3 2017 PERMIT CENTER 0 z 0 0 LEGENDS 1 a z w 0 z Z L� 0 i w O E O I- U Z w oz 0 0 U � W m >-� Q� o Z W I- U O� 0 O Irl 2 O� I- O- z Z o m z CHECKED: z 0 DECEMBER 22 REVISION DATE: ISSUE PLUMBING z By Ferguson Construction, Inc. on 01/03/2017 c 0 12/22/2016 0 U 0 0 0 0 0 0 0 U K:\2015\300-309\15-302 CONICAL SPIN -IN VOLUME DAMPER FLEX DUCT 10' MAX. 41F/MnallP4 DU MIN NYLON TIE -STRAPS LAY -IN CEILING DIFFUSER TYPICAL ANCILLARY STRUCTURE (PHARMACY, OPTICAL, OFFICE, HEARING, E.D.P) CURB AND FLASHING PER ARCH. PROVIDE HOLD DOWN CABLE PER DETAIL Jr-- \N, r— DIFFUSER INLET DETAIL SCALE: NONE 2" VENT — THRU ROOF TRAP PRIMER 2" WASTE IN WALL FROM OPTICAL SINK. 2" WASTE IN WALL VP WASTE FROM SINK P -TRAP HOT WATER ASME P&T RELIEF VALVE COLD WATER 2"/3" ADAPTER HUB DRAIN 12 UNION 7-- WATER HEATER TO BE INSTALLED TIGHT AGAINST SIDE WALL. DISCHARGE PIPE TO 3" DIA. HUB DRAIN AND DAYLIGHT C� + 3" ABOVE RIM I�-CATCH PAN FINISHED FLOOR DAYLIGHT CATCH PAN DRAIN TO CONCRETE UNDER SINK WATER HEATER (WH -10) SCALE: NONE 56 ROOF SIZE PER PLAN DUCTS MUST RUN STRAIGHT DOWN PERPENDICULAR TO FLOOR, FROM ROOF TO TOP OF STRUCTURE DUCTS TO BE INTERNALLY INSULATED FOR RUN BETWEEN BUILDING ROOF AND ANCILLARY FRAMING DUCT TO BE SUPPORTED BY ANCILLARY FRAMING. CEILING SA GAS PRESSURE REGULATOR LJ FLEX CONNECTION ALL HORIZONTAL DUCT AND OFFSETS TO BE CONCEALED FROM VIEW VDi i-� RA LIGHTS TYPICAL ANCILLARY STRUCTURE (FOOD SERVICE, OPTICAL IN CANOPY) 0: SEE FIRE PROTECTION DRAWINGS FOR SMOKE DETECTOR REQUIREMENTS. PROVIDED BY FIRE ALARM CONTRACTOR INSTALLED BY M.C. (SEE SPEC FOR FIRE ALARM CONTRACTOR RESPONSIBILITY) 1 AC UNIT 8c DUCT ELEVATION DETAIL SCALE: NONE AIR TERMINAL SCHEDULE SYMBOL MANUFACTURER SERVICE MODEL PATTERN DAMPER NECK FRAME LOCATION * CD TUTTLE & BAILEY SUPPLY SQD BLADE 64/H-1lj LAYIN OFFICES, OPTICAL RG TUTTLE & BAILEY RETURN PR PERFORATED 56/M1 LAYIN OFFICES, OPTICAL * VERIFY NUMBER OF DIFFUSERS AND ALL LOCATIONS ON PLANS - DIFFUSER IS NOT REQUIRED IF NOT ON PLANS ** DIFFUSER TO HAVE BRUSHED STAINLESS STEEL FACE. DO NOT PROVIDE WITH FILTER. PLUMBING FIXTURE SCHEDULE — SUPPLIED BY OWNER INSTALLED BY CONTRACTOR (SOIC) FIXTUREDSCHEDULE — CONTRACTOR PROVIDED SYMBOL DESCRIPTIONMFR. /MODEL /W. 1-1/2"1/2"1/2"DEEP VENT HOT W. SPECIFICATIONS DETAIL SERVES NOTES W P CKFL W N 64/H-1lj 120ER HEATER EMTMAX BACKFLOW POTENTIAL LH - LOW HAZARD HH - HIGH HAZARD 1/2" 1/2" 2.5 GAL., ELECTRIC WATER HEATER, 1.2KW, 120V/10, 10 AMPS. 6.0 GPH © 100' RISE 56/M1 OPTICAL (3) N/A PLUMBING FIXTURE SCHEDULE — SUPPLIED BY OWNER INSTALLED BY CONTRACTOR (SOIC) OPTICAL EXAM SINK EXISTING UNIT DATA 2" 1-1/2"1/2"1/2"DEEP SERVES 18 GAUGE TYPE 302 SELF RIMMING STAINLESS STEEL, LEDGE TYPE, SINGLE COMPARTMENT SINK, 15"x17 -1/2"x7-1/2" WITH FAUCET LEDGE. ELKAY LK -4121 CHROME FAUCET, SWING SPOUT WITH 10 OUTLET HEIGHT. 8" REACH, LK -335 SINK DRAIN & TAILPIECE. ELECT. OPTICAL REFERENCE LH -BS AG ( OES MFR/# (3) WATER HEATERS TO HAVE RIGID CONNECTIONS & CONSTRAINTS TO RESIST SEISMIC MOTION. HAZARD TYPE BACKFLOW POTENTIAL LH - LOW HAZARD HH - HIGH HAZARD BS - BACK SIPHONAGE BP - BACK PRESSURE BACKFLOW PREVENTION RPZ - REDUCED PRESSURE PRINCIPLE BACK FLOW PVB - PRESSURE VACUUM BREAKER AG - AIR GAP AVB - ATMOSPHERIC VACUUM BREAKER HVAC EQUIPMENT SCHEDULE—S.O.I.C. STRUCTURAL VERIFICATION EXISTING UNIT DATA SYMBOL ITEM SERVES MFR/# DESCRIPTION ELECT. WEIGHT REFERENCE REMARKS NOTES MFR/# HEAT ELECTRICAL NET WEIGHTS NEW NET WEIGHTS REMARKS AC -5 AIR CONDITIONER Optical TRANE 4YCC4024A 1060A 24 MBH TOTAL COOLING, 21 MBH SENSIBLE, 81.3 AMB, 91.3 EDB, 66.9 EWB, 800 CFM 60 MBH E NSPPUT, SEER 48.6MBH OUTPUT, 81% AFUE = 14, 208V/10 30 MCOP 19.1 MCA PLAN M-1 10/M-1 150 CFM MIN 0/A (5) (7) (23) ( 25) TRANE YCC018 NATURAL GAS 40 MBH 208/1 V/0 20 MCOP 13.2 MCA 341 #:(E)UNIT 51 #:(E)CURB X42 :50 �E�TOTAL DUCT 388 #:NEW}CURB UNIT 51 (E 84 :ADAPTER 873 :NE)WDUCT TOTAL NEW UNIT WEIGHTS 131# MORE THAN EXISTING CONDITION General HVAC Notes - ALL EQUIPMENT FURNISHED BY COSTCO, INSTALLED BY M.C. CONTACT COSTCO PURCHASING DEPT. TO COORDINATE DELIVERY TIME ® EMAIL: LPERRY©COSTCO.COM - AC UNITS PROVIDED WITH DDC COMMUNICATIONS INTERFACE CONTROLLED BY BUILDING MANAGEMENT SYSTEM BY CONTROLS INSTALLER. SENSOR/T'STAT S.I.0. SENSORS ® +72", T'STATS AT 48" A.F.F. - CONTRACTOR TO INSTALL ALL ITEMS LISTED IN EQUIPMENT SUBMITTAL PER MANUFACTURERS INSTALLATION AND OPERATION MANUAL. - AC UNITS TO BE SUPPLIED WITH THE FOLLOWING FACTORY INSTALLED OPTIONS: THROUGH -THE -BASE ELECTRICAL WITH CIRCUIT BREAKER, 120V/15AMP CONVENIENCE OUTLET, STANDARD 2" MERV-4 FILTERS, HINGED ACCESS DOORS AND VAV SUPPLY AIR BLOWER WHERE AVAILABLE; UNLESS OTHERWISE NOTED. - AC UNITS TO BE SUPPLIED WITH FIELD INSTALLED THROUGH -THE -BASE GAS PIPING CONNECTION AND HAIL GUARD. - ROOF CURBS PROVIDED BY M.B.S. UNLESS OTHERWISE NOTED. HVAC ITEM NOTES (5) TO BE SUPPLIED WITH FACTORY INSTALLED LOW LEAK ECONOMIZER AND BAROMETRIC RELIEF. (7) TO BE SUPPLIED WITH PROGRAMMABLE ELECTRONIC NIGHT SET -BACK THERMOSTAT. (23) ADAPTER CURB BY G.C. (25) TO BE SUPPLIED WITH FIELD INSTALLED DISCONNECT SWITCH AND 120V/15AMP CONVENIENCE OUTLET BY E.C. RECEIVED CITY OF TUKWILA JAN 232017 PERMIT CENTER By Ferguson Construction, Inc. on 01/03/2017 SCHEDULES z H W m F- 2 DECEMBER 22, 2016 REVISION DATE: ISSUE DATE: JULY 2016 ARCHITECT REFERENCE NO: 93-0440-30 w -J 0 z zw 0 w0 LI- E- O% N o00 c..) w cnz U.1 m a 0 w gw I- U O F. 0 0 TE - of F-0_ 0_Z 0Q Z O PROJECT N0:15-302 ISSUED FOR PERMIT ISSUED FOR BID PERMIT REVISIONS to O) O N N 0) LCD rirIN co A M o IN ig CV CV w� zWoz cG�Wx� aocnxa1=, REVIEWED FOR CODE COMPLIANCE APPROVED JAN 27 2011 City of Tukwila BUILUINU DIVISION Remodel\3O2E-1 .dwg, K:\2015\300-309\15-302 LEGEND a 0 0 0 b FIXTURE TYPE EXISTING LIGHTING FIXTURE REMOVE AND RELOCATE LIGHTING FIXTURE LIGHTING FIXTURE FLUORESCENT LIGHT FIXTURE a SUB -LETTER INDICATES CONTROLLING SWITCH SUB-LETTER LAMP(S) CONTROLSIrINNERITLLAHMP(SCONTROLS SINGLE POLE SWITCH, +42" LAMP( SUB-LETTER INDICATES FIXTURE CONTROLLED, +42" THREE POLE SWITCH, +42" DUPLEX RECEPTACLE, +18" OR AS NOTED ISOLATED GROUND DUPLEX RECEPTACLE, +18" OR AS NOTED ISOLATED GROUND FOUR -FLEX RECEPTACLE, +18" OR AS FOUR-PLEX RECEPTACLE, +18" OR AS NOTED JUNCTION BOX, SIZE AND TYPE PER CODE HACR BREAKER IN NEMA ENCLOSURE, COORDINATE W/ EQUIPMENT SUPPLIER. O m D' rr`') NOTED +48" E.C. WP GFI TYP. FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER NON-FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER TELEPHONE OUTLET WITH 3/4" CONDUIT TO CEILING SPACE OR AS SHOWN 3 -WAY DIMMER SWITCH, BRAND: SYNERGY ISD BC 120/277 OR EQUAL CONDUIT IN CEILING OR WALL, 1/2" MIN. CONDUIT UNDERGROUND OR FLOOR, 3/4" MIN. HOME RUN TO PANEL WITH CIRCUIT NUMBER, SLASHES INDICATE NUMBER OF CONDUCTORS ETEDUTOIT OPLSHC## IT1/2"CC - MALLICCONIPVCATICONDU ISOLATED GROUND OR GROUND CONDUCTOR FLEXIBLE CONDUIT CONNECTION AS REQUIRED BRANCH PANEL INDICATES MOUNTING HEIGHT OF EQUIPMENT/OUTLET CENTER LINE ABOVE FINISH FLOOR ELECTRICAL CONTRACTOR WEATHER PROOF GROUND FAULT CIRCUIT INTERRUPTER TYPICAL ELECTRICAL DEMOLITION GENERAL NOTES ELECTRICAL CONTRACTOR SHALL REFER TO THE ARCHITECTURAL DEMOLITION PLANS FOR THE SCOPE OF CORRESPONDING BUILDING DEMOLITION WORK. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND TO WORK. REMOVAL OF EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND REMOVING OF THE EXISTING CONDUITS AND WIRING BACK TO THE NEXT ACTIVE OUTLET OR SOURCE. PROVIDE MATCHING BLANK COVER PLATE AS REQUIRED. REMOVE OR ABANDON ALL UNUSED UNDERGROUND, UNDER FLOOR RACEWAYS. REMOVE ALL UNUSED SURFACE RACEWAYS. RELOCATE EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND EXTENDING EXISTING CONDUITS AND WIRING TO NEW LOCATION, PROVIDE NEW CONNECTION AS REQUIRED. PROVIDE CUTTING, PATCHING, TRENCHING AND BACK FILL FOR ALL RELATED ELECTRICAL WORK AS REQUIRED. ALL REMODEL WORK SHALL BE PERFORMED NOT TO INTERFERE WITH OWNER'S NORMAL OPERATION, COORDINATE AND SCHEDULE WITH OWNER, ARCHITECT FOR WORK SCHEDULE. PERFORM WORK DURING OFF BUSINESS HOURS AS REQUIRED. COORDINATE AND SCHEDULE WITH OWNER FOR ANY EXISTING ELECTRICAL SERVICE SHUT DOWN, PROVIDE TEMPORARY POWER TO MAINTAIN EXISTING ELECTRICAL SYSTEM FOR OWNER'S NORMAL OPERATION AS REQUIRED. LIGHTING FIXTURE SCHEDULE ALL LIGHT FIXTURES SHALL HAVE FACTORY INSTALLED DISCONNECTED MEANS PER LATEST NEC CODE TYPE MANUFACTURER NUMBER LAMPS MOUNT WATT REMARKS OHOLOPHANE* A PHASE A RE35LPP272RSFW C6 COSTCO VENTURE MP 350W/BU UVS/PS CHAIN 382 BOTTOM OF FIXTURE +23' A.F.F. E.C. TO PROVIDE SAFETY HOOKS, FLEXIBLE WIRING SYSTEM & WIRING ACCESSORIES AS REQUIRED SEE DETAIL 1 /THIS SHEET. DO LITHONIA 2GTL 4 G 72L LP841 BLD LAIC LED RECESS 71 BI -LEVEL DIMMING & EARTHQUAKE CLIPS. D1 LITHONIA SAME AS D, BUT WITH 0-1OV DIMMING DRIVER EL PROVIDE EMERGENCY BATTERY PACK OPTION WHERE OF 1400 -LUMEN FOR LED LIGHT OUTPUT FOR 90 INDICATED ON PLANS. INCLUDE ALL RELAY, TEST SWITCH AND CAPACITY -MINUTE. NOT A NIGHT LIGHT. SELF DIAGNOSTIC FEATURE WP.Gl1 42 #10 PHOTO/ 11,4 EXISTING RE (DUO aD A EXISTING SUMP PUMP TO REMAIN FD ES TO REMAIN 1111M1111 -..- ACCESS AT - +1'-6" & 6'-9" - WH -10. E.C. TO COORDINATE RECEPTACLE LOCATION W/ M.C. PHOTO/39 • 0C1/2 PHOTO/37 XLu • • 1/ 5C BETWEEN WIREWAYS. ACCESS AT +2'-4" u y -e GENERAL NOTES 2. 3. 4. 5. MINIMUM WIRE & CONDUIT SIZE ARE #12 CU & 1/2"C. TYP. NO ALUMINUM WIRE ALLOWED. ALL BREAKER AIC RATINGS TO MATCH PANEL AIC RATINGS. ALL U.L. LISTED EQUIPMENT SHALL BE INSTALLED AS PER THEIR LISTING OR LABELING. ALL WORK TO COMPLY WITH 2015 INTERNATIONAL CODES. PLAN NOTES: Q1 E.C. TO REMOVE ELECTRICAL DEVICES, CONDUITS, WIRES IN DEMO AREA (SEE ARCHITECTURAL PLAN) TO SOURCE. PROVIDE "SPARE" LABEL AND TURN BREAKERS TO "OFF" POSITION. EXTEND EXISTING FEEDERS FOR CONTINUITY AS REQUIRED. E.C. TO MAKE ALL FINAL ELECTRICAL CONNECTIONS (INCLUDING LOW -VOLTAGE) FOR ALL OWNER SUPPLIED EQUIPMENT. 03 PLUGMOLD & LIGHTING IN KIOSK ARE SUPPLIED BY OWNER, INSTALLED BY ELECTRICAL CONTRACTOR. ® ALL OUTLETS, LIGHT SWITCHES, ELECTRICAL DEVICES IN EXAM ROOMS SHALL BE HOSPITAL GRADE. NO M.C. (FLEX) WIRING ALLOWED. PER NEC 517-13. 0 PROVIDE PLUGMOLD, WITH RECEPTACLE EVERY 12" ON CENTER, MOUNT PLUGMOLD ABOVE COUNTER. © WIREMOLD (S166B) BRASS COMMUNICATION FITTING (COVERPLATE), WITH WIREMOLD (437-7/8") ATTACHMENT RING WITH ACCESS PENETRATION TO HOFFMAN 3"x3" WIREWAY FOR OWNER INSTALLED DATA CABLING AT HEIGHTS SHOWN ON POWER PLAN. PROVIDE AN ADDITIONAL (437-7/8") ATTACHMENT RING WITH ACCESS PENETRATION TO HOFFMAN 3"x3" WIREWAY AT 8'-9" (IN CEILING SPACE, NO COVERPLATE NEEDED), TYPICAL FOR ALL DATA CHASES. PROVIDE ALL ACCESSORIES AS REQUIRED. WIREMOLD ATTACHMENT RINGS (437-7/8"), COVERPLATES (S166B) & 9 -FT HOFFMAN 3"X3" WIREWAYS TO BE PURCHASED / SUPPLIED FROM GRAYBAR ELECTRIC (206-292-4848). SEE DETAIL 2 SHEET E-1 AND ARCHITECTURAL OPTICAL PLANS. PROVIDE PULL STRING IN CHASES. 07 MOUNT CLEAN POWER RECEPTACLE IN LOWER CABINETRY ON THE INNER SIDE WALL OF CABINET TO MAKE SURE CABINET DRAWER CAN CLOSE PROPERLY WITH CORD PLUGGED INTO THE RECEPTACLE. COORDINATE EXACT LOCATION WITH REGIONAL OPTICAL MANAGER. © SAME AS NOTE #6, EXCEPT USE HOFFMANN 4"X4" WIREWAY AT THIS LOCATION IN EACH OPTICAL EXAM. • WIREMOLD (S166B) BRASS COMMUNICATION FITTING (COVERPLATE), WITH WIREMOLD (437-7/8") ATTACHMENT RING WITH ACCESS PENETRATION TO HOFFMAN 4"x4"(X12") WIREWAY FOR OWNER INSTALLED DATA CABLING AT HEIGHTS SHOWN ON POWER PLAN. PROVIDE 2" HORIZONTAL CONDUIT BETWEEN THE (2) 4"X4" WIREWAYS IN EACH EXAM ROOM. 1 -FT HOFFMAN 4"X4" WIREWAYS TO BE PURCHASED / SUPPLIED FROM GRAYBAR ELECTRIC (206-292-4848). SEE DETAIL 1 ON SHEET E-1 AND ARCHITECTURAL OPTICAL PLANS. PROVIDE PULL STRING IN CHASES. 10 E.C. TO REUSE EXISTING CIRCUIT IN EXISTING PANEL C1. FIELD VERIFY. Q E.C. TO REMOVE EXISTING RECEPTACLE AND PROVIDE NEW RECEPTACLE AT NEW LOCATION AS SHOWN. INTERCEPT EXTEND FEEDER TO NEW LOCATION, REPULL WIRE AS REQUIRED. EXTEND FEEDER TO MAINTAIN FOR CONTINUITY REUSE EXISTING CIRCUIT. FIELD VERIFY. © EXISTING HVAC UNIT TO BE REMOVED AND REPLACE WITH NEW AC AS SHOWN. E.C. TO REMOVE EXISTING FEEDER AND PROVIDE NEW FEEDER AS SHOWN. FIELD VERIFY. 0 15 © 0 VERIFY LOCATION OF POWER POLE AND CEILING J- BOXES WITH OWNER BEFORE INSTALLATION. E.C. TO REMOVED EXISTING FLUORESCENT LIGHTS AS SHOWN, EXTEND EXISTING FEEDER FOR CONTINUITY. PROVIDE NEW WIRES AS REQUIRED. FIELD VERIFY. CONNECT TO EXISTING RECEPTACLE E.C. TO REMOVED EXISTING RECEPTACLE, PHONE JACK AND ASSOCIATED FEEDER AND WIRES. EXTEND FEEDER FOR CONTINUITY. PROVIDE NEW WIRES AS REQUIRED. FIELD VERIFY. E.0 TO PROVIDE (2) 20A/1P BREAKERS IN EXISTING PANEL "L" FOR NEW OPTICAL LIGHTING. VERIFY IN FIELD. PHOTO/28,30 QO C1/22,2 PHOTO/24,26 - ACCESS AT +1'-6" #8,1 "C EXISTING TRANSFORMER EXISTING PANEL PHOTO 2 (11 WHITE PLUGMOLD, 24" ON CENTER, TOP EDGE OF PLUGMOLD +86" A.F.F. . 2"x2", 2 HANNEL WHITE FINISH POWER POLE. LENGTH AS REPHOTOUIRED TO CEILING STRUCTURAL. PROVIDE UNITRUT FOR ATTACHMENT AS REPHOTO. 21'-6" HEIGHT SET ON TOP OF COUNTER TOTAL HT. CSD +24'-0". TYPICAL OF 4 PLUGMOLD. Q3 OPTICAL - POWER PLAN SCALE: 1/4" = 1'-O" Ly40 1© OPTICAL - LIGHTING PLAN SCALE: 1/4" = 1'-O" DRYWALL PER ARCH 9 -FT HOFFMAN 3"X3" (4"X4") WIREWAY TO SPACE ABOVE CEILING. ATTACHMENT RING 437-7/8" COMMUNICATION FITTING S166B (COVERPLATE) SPACER/SUPPORT AS REQUIRED TRUSS NOTE: THIS DETAIL IS TYPICAL FOR ALL ACCESS PENETRATIONS TO WIREWAY. HEIGHT OF PENETRATIONS ARE SPECIFIED ON PLAN. AN ADDITIONAL PENETRATION AT 8'-9" (IN CEILING SPACE) IS TYPICAL FOR ALL CHASES - NO COVERPLATE NEEDED FOR CEILING SPACE PENETRATION. 2 1"C 62 know 24 1"C TO PLUGMOLD PHOTO/26 INSULATION TYPICAL OF 4 PLUGMOLD. 03 MOUNT SWITCH INSIDE LOWER CABINET. VERIFY EXACT LOCATION W/ OWNER. BEAM CLAMP (UNISTRUT #PFLO37T OR EQUAL) / ROOF (K) _II 1 ��EXISTING TRANSFORMER Q (QUEST _� �-EXISTING PNL Q (QUEST) - n 0 AREA OF WORK .i' -r - RLQ O RLZI O Q LR/ P/ LI ii ip rI i) 0 0 U (4) 0 #io L/42 1© 0 0 0 0 X X X L 0 EXISTING PANEL L EXISTING LRP -L By Ferguson Construction, Inc. on 01/03/2017 INSULATION OPTICAL/EXAM ROOM WALL DUCT DETAIL C) UNISTRUT #P3300 (1-5/8" X 7/8") -� LOCKED HOOKS (SEE ENLARGED VIEW LIGHTING FIXTURE SCHEDULE) -STEEL TRUSSES 5' ON CENTER VERIFY W/ROOF SHOP DRAWINGS. NOTES: SAFETY CHAIN UNISTRUT #P3300 (1-5/8" X 7/8") WITH UNISTRUT BEAM CLAMPS #PFLO37T OR EQUAL TO TRUSS - 2 PLACES. FLEXIBLE WIRING SYSTEM SAFETY CHAIN BOTTOM OF FIXTURE +23' A.F.F. TYPICAL. ADJUSTABLE CHAIN HANGER TO MEET 23' FIXTURE CLEARANCE HEIGHT. IF ANY CONFLICTS OCCUR WITH TRUSSES, COORDINATE FIXTURE RELOCATION WITH ARCHITECT/ENGINEER. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL MOUNTING ACCESSORIES AS REQUIRED, INCLUDING SAFETY HOOKS, CHAIN, UNISTRUT, ETC. FOR FIXTURE MOUNTING. PROVIDE STAINLESS STEEL STRANDED SAFETY CHAIN. SECURE BETWEEN FIXTURE/BALLAST BODY AND THE NEAREST BUILDING STRUCTURE MEMBER. TYPICAL ALL H.I.D.'S H. I. D. FIXTURR MOULTING DETAIL NO SCALE E - II ryy rr. 111 PARTIAL FLOOR PLAN SCALE: 1/16" = 1'-0" EXISTING LIGHTING CONTROL SCHEDULE LRP -L COSTCO - TUKWILA, WA FUNCTION SALES AREA 1ST GROUP ON/Off CIRCUITS # S L/1 L/11 L/15 L/19 L/37 z 0 1 L/16 L/20 L/29 L/30 L/33 L/34 FUNCTION SALES AREA 2ND GROUP ON/OFF CIRCUITS # S L/7 L/17 L/21 L/39 L/18 L/22 L/25 L/26 L/35 L/36 z w L/2 L/4 L/12 L/8 FUNCTION SALES AREA 3RD GROUP ON/OFF CIRCUITS # S L/5 L/9 L/13 L/23 L/41 L/42 L/14 L/24 L/27 L/28 L/31 L/32 L/6 L/10 PROVIDE (10) SPARE RELAYS FOR FUTURE OR OTHER LIGHTING CIRCUIT(S) RELOCATED FROM EXISTING LCC. EXISTING NEW (A) 1 11 u l EXIST. TRANS TC1 & PANEL H1 EXIST. PANELS C1 & P1 EXISTING MEZZ. 2 PLAN SCALE: 1/8" = 1'-0" PANEL: PHOTO 208 / 120 VOLTS 3 PHASE 4 WIRE 225 A CU BUS W/ 200A/3P MAIN 10000 A.I.C. MIN. EXISTING TOP FEED SURFACE MOUNT SQ -D NQOD CIRCUIT USE PHASE A (KVA) B C BKR. CKT.CKT. NO. NO. BKR. PHASE A (KVA) B C CIRCUIT USE EXISTING LOAD 0.50 20/1 1 2 50/2 2.00 MECH A EXISTING LOAD 1.00 20/1 3 4 2.00 EXISTING LOAD 1.00 20/1 40/2 5 7 6 8 20/1 30/2 1.20 1.00 DROP CORD FRONT END COFFIN CASE MECH B 1.50 1.50 9 10 1.20 AC -5 * 2.00 30/2 11 12 20/1 SPARE 2.00 13 14 30/2 1.20 PLUGMOLD FENCE RECEPT. 0.80 120/1 15 16 1.20 FENCE RECEPT. 0.80 20/1 17 18 SPACE COFFIN CASE 1.20 30/2 19 20 30/2 0.80 DROP CORD END ROW 1.20 21 22 0.80 3-5 KIOSK EXISTING LOAD 0.80 20/1 23 24 1.00 OPTICAL KIOSK * EXISTING LOAD 0.80 20/1 25 26 20/1 1.00 OPTICAL KIOSK * EXISTING LOAD 0.80 20/1 27 28 20/1 1.00 PLUGMOLD - OPTICAL * SPACE 29 30 20/1 1.00 PLUGMOLD - OPTICAL * OPT RECEPTION RECEPTACLE * 1.08 20/1 31 32 20/2 0.36 NORTH WALL RECEPTACLE EXAM ROOM 174 RECEPTACLE * 1.08 20/1 33 34 0.36 OPTICAL PLUGMOLD * 1.00 20/1 35 36 20/2 0.36 NORTH WALL RECEPTACLE OPTICAL RECEPT. * 1.00 20/1 37 38 0.36 WATER HEATER WH -10* 1.00 20/1 39 40 20/2 0.36 NORTH WALL RECEPTACLE ROOF RECEPTACLE * 0.18 20/1 41 42 0.36 TOTAL PHASE A (KVA) TOTAL PHASE B (KVA) TOTAL PHASE C (KVA) 7.28 8.18 5.78 14.2 KVA 15.1 KVA 9.5 KVA 6.92 6.92 3.72 RECEIVED CITY OF TUKWILA TOTAL CONNECTED LOAD 38.8 KVA 107A * NEW LOAD. PROVIDE BREAKER AS SHOWN JAN 232017 PANEL: C1 EXISTING 208 / 120 VOLTS 100 A CU BUS 50A/3P MAIN TOP FEED 3 PHASE SURFACE MOUNT 5 WIRE 10000 A.I.C. MIN. SQ -D NQOD PERMIT CENTER CIRCUIT USE PHASE (KVA) A B C CKT. CKT. BKR. NO. NO. BKR. PHASE (KVA) A B C CIRCUIT USE RECEPTACLE 0.36 15/1 1 2 15/1 0.20 OPTICAL RECEPT. * LEGEND, DETAIL SCHEDULE, W z SCHEDULE, H H H z POWER AND LIGHTING 0 CHECKED: x x DECEMBER 22, 2016 REVISION DATE: ISSUE DATE: JULY 2016 ARCHITECT REFERENCE NO: 93-0440-30 w J 0 z zw 0 w� oz w IX U) o 0 0 �w w1- m� 0 �c w a w U I- ° F_ o� ,0 w� o� az zo ISSUED FOR PERMIT ISSUED FOR BID co co M 00 RECEPTACLE RECEPTACLE RECEPTACLE RECEPTACLE 0.36 0.36 0.36 0.36 15/1 15/1 15/1 15/1 3 5 7 9 4 6 8 10 15/1 20/1 15/1 15/1 0.18 0.36 0.54 TIRE RECEPTACLE WATER TREATMENT WATER TREATMENT 0.18 CLEAN CONTROL RM RECEPTACLE 0.36 15/1 11 12 15/1 0.54 RECEIVING DESK PHARMACY RECEPT. 0.36 15/1 13 14 15/1 1.00 R & D COMPUTER PHARMACY RECEPT. 0.36 15/1 15 16 15/1 0.50 SECURITY PHARMACY RECEPT. 0.36 15/1 17 18 15/1 0.50 DEU PREP SCALE PHARMACY RECEPT. PHARMACY RECEPT. SPACE UNSUSED SPACE UNSUSED SPACE UNSUSED SPACE TOTAL PHASE A (KVA) TOTAL PHASE B (KVA) TOTAL PHASE C (KVA) TOTAL CONNECTED LOAD 0.36 0.36 1.44 1.44 *REVISED LOAD, PROVIDE NEW BREAKER AS REQUIRED 1.08 15/1 19 20 15/1 15/1 21 22 15/1 23 24 15/1 25 26 --- - -- 27 28 -- - -- 29 30 3.68 KVA/ 3.02 KVP 3.2 KVA 9.9 KVA 0.50 ROTISS SCALE R. I :WED PDR CODE-{.OMPLI kNCE ROVE g` 27 20 r N City )f itp BU14. JG pIV •ION O H z U I-�-I w <4 o a_ NA - 0.72 0.72 OPTICAL KIOSK * OPTICAL KIOSK * UNSUSED SPACE UNSUSED SP UNSU a