Permit PG17-0025 - BOEING #9-120 - PRESSURE BACKFLOW PREVENTER
BOEING #9-120 9725 E MARGINAL WAY S PGI 7-0025 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 0003400018 Permit Number: PG17-0025 9725 E MARGINAL WAY S BLDG 9-120 Issue Date: 3/15/2017 Permit Expires On: 9/11/2017 Project Name: BOEING #9-120 Owner: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 Contact Person: Name: AMANDA MOORE Address: 11621 E MARGINAL WAY S , TUKWILA, WA, 98168 Contractor: Name: Address: License No: Lender: Name: Address: Phone: (206) 812-7683 P S F MECHANICAL INC Phone: (206) 764-9663 11621 E MARGINAL WAY S SUITE A , TUKWILA, WA, 98168-1965 PSFMEI*090NZ I II Expiration Date: 10/5/2017 DESCRIPTION OF WORK: INSTALL DOMESTIC WATER REDUCED PRESSURE BACKFLOW PREVENTER 3/4". WATTS Series LF909 Valuation of Work: $1,250.00 Water District: TUKWILA Sewer District: VALLEY VIEW,TUKWILA Fees Collected: $172.13 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: �C�� Date: 03//f77 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: RYVVO.tY\ Af"30( Date: -61r) 11 -1 - This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 8: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 9: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 10: Contractor shall call Public Works at 206 433-0179 to schedule the backflow inspection. RPPA shall be installed per manufacturer's specifications and shall be tested by a certified tester. Passing backflow test report shall be submitted to Dave Stuckle, Public Works Inspector, phone 206 433-0179. Thereafter the backflow shall be tested annually at the building owner's expense and copy of the test report forwarded to Tukwila Water Dept., 600 Minkler Blvd, Tukwila, WA 98188, phone 206 433-1860, fax 206 575-3404. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwvv.TukwilaWA.gov Plumbing/Gas Permit No. TG % — 00)-S— Project No. Date Application Accepted: —>) t Date Application Expires: 'r� } l (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 0003400018 Site Address: 9725 E Marginal Way S, Bldg 9-120 Suite Number: Floor: 1 Tenant Name: Boeing PROPERTY OWNER Name: Amanda Moore Name: The Boeing Company City: Seattle State: WA Zip: 98168 Address: PO Box 3707 Email: permits@psfmech.com City: Seattle State: WA Zip: 98124 ' CONTACT PERSON — person receiving all project communication Name: Amanda Moore Address: 11621 E Marginal Way S, Suite A City: Seattle State: WA Zip: 98168 Phone: (206) 812-7683 Fax: Email: permits@psfmech.com New Tenant: ❑ Yes ® .. No PLUMBING CONTRACTOR INFORMATION Company Name: PSF Mechanical, Inc. Address: 11621 E Marginal Way S, Suite A City: Seattle State: WA Zip: 98168 Phone: (206) 812-7683 Fax: (206) 762-8381 Contr Reg No.: PSFMEI*090NZ Exp Date: 10/05/2017 Tukwila Business License No.: BUS -0996384 Valuation of Project (contractor's bid price): $ 1,250 Scope of Work (please provide detailed information): Install Domestic water reduced pressure backflow preventer. Building Use, (per Int'! Building Code). Commercial Occupancy (per Int'! Building Code): Group B Utility Purveyor: Water: Tukwila Sewer: Tukwila Sewer Service H:\ApplicationsWorms-Applications On Line\2011 Applications \Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page I of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 1 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmosphcric- type vacuum breakers 2 inch (51 mm) diameter or smaller 1 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric-typc vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protcction devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING S W 0 AUTHOORIZED AGENT: Signatur Date: Print Name: Amanda Moore Day Telephone: (206) 812-7683 Mailing Address: 11621 E Marginal Way S, Suite A H:\Applications\Forms-Applications On Lint: \2011 Applications\Plumbing Pcrmit Application Revised 8-9-11.docx Revised: August 2011 bh Seattle WA 98168 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $139.03 PG17-0025 Address: 9725 E MARGINAL WAY S.BLDG 9-120 Apn: 0003400018 $139.03 Credit Card Fee $4.05 Credit Card Fee R000.369.908.00.00 0.00 $4.05 PLUMBING $128.55 PERMIT FEE R000.322.100.00.00 0.00 $95.40 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $6.43 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11079 R000.322.900.04.00 0.00 $6.43 • $139.03 Date Paid: Wednesday, March 15, 2017 Paid By: PSF MECHANICAL INC Pay Method: CREDIT CARD 533558 Printed: Wednesday, March 15, 2017 10:26 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $125.01 M17-0025 Address: 9725 E MARGINAL WAY S BLDG 9-120 Apn: 0003400018 $91.91 Credit Card Fee $2.68 Credit Card Fee 1 R000.369.908.00.00 0.00 $2.68 MECHANICAL $89.23 PLAN CHECK FEE 1 R000.322.102.00.00 0.00 $89.23 PG17-0025 Address: 9725 E MARGINAL WAY S BLDG 9-120 Apn: 0003400018 $33.10 Credit Card Fee $0.96 Credit Card Fee R000.369.908.00.00 0.00 I $0.96 PLUMBING $32.14 PLAN CHECK FEE R000.322.103.00.00 0.00 TOTAL FEES PAID BY RECEIPT: R10869 $32.14 $125.01 Date Paid: Wednesday, February 22, 2017 Paid By: AMANDA MOORE Pay Method: CREDIT CARD 347714 Printed: Wednesday, February 22, 2017 9:38 AM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 ►` n -oar 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: iaev ei - /2e T e of Inspection V a-Jv 2v?r3/do- Address: Date Called: Special Instructions: &9/20 Date Wanted: / a m: Requester /i Phone No: 206; ---7 1 g - eq 2 'f Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: �K- R) -/+--'N cls - Inspector: .XS Dater/3—/7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. lul J PSF PSFMechanical_ ACCOUNT/ID # NAME OF PREMISES SERVICE ADDRESS CONTACT PERSON LOCATION OF ASSEMBLY DOWNSTREAM PROCESS BACKFLOW 11621 E Marginal Way S Seattle, WA 98168 HVAC Service 1 206.812.2878 (24/7/365) Main Office 1 206.764.9663 Boeing 9-120 9725- E. Marginal Way South In Bldg 9-120 by sink in Engineering ASSEMBLY TEST REPORT JOB #: RETURN NO LATER THAN: RECEIVED CITY OF TUKWILA APR 13 201 PEWIT CENTER COMMERCIAL [] RESIDENTIAL ❑ CITY Tukwila ZIP FAX PHONE Filter flush NEW INSTALL ❑ EXISTING ❑ REPLACEMENT DCVA ❑ ❑ OLDER SER. # MAKE OF ASSEMBLY: Watts MODEL: LF909QT RPBA Q PVBA ❑ OTHER PROPER INSTALLATION? YES SERIAL NO.: 0322342 SIZE: 0.75 NO ❑ INITIAL TEST PASSED FAILED • DCVA /RPBA DCVA / RPBA RPBA 5.40 PSID PVBA / SVBA PSID 0 CHECK VALVE NO. 1 CHECK VALVE NO. 2 . OPENED AT AIR INLET LEAKED PSID LEAKED PSID OPENED AT #1 CHECK AT 9.00 PSID DID NOT OPEN AIR GAP OK? • • • Closed Tight NEW PARTS AND REPAIRS CLEAN REPLACE PART CLEAN REPLACE PART CLEAN REPLACE PART CHECK VALVE HELD AT PSID Il 111 ❑ • • ❑ • LEAKED ■ I ■ $ ❑ • • • • 0 • • 0 CLEANED REPAIRED ❑ ■ a 1 $ 0 TEST AFTER REPAIRS PASSED FAILED • LEAKED • PSID LEAKED • PSID OPENEENEDAT PSID AIR INLET PSID PSID #1 CHECK AT PSID CHECK VALVE 0 AIR GAP INSPECTION: Required minimum air gap separation provided? DETECTOR METER READING REMARKS: YES ❑ NO ❑ TESTERS SIGNATURE: TESTERS NAME PRINTED: REPAIRED BY: FINAL TEST BY: CALIBRATION DATE: L. Angus LINE PRESSURE SO PSI CONFINED SPACE? No CERT. NO. B 0255 DATE: 03/21/17 TESTERS PHONE # 206-812-2878 CERT. NO. 09/07/15 GAUGE # 12090588 MODEL: MW 830 DATE: DATE: SERVICE RESTORED? YES NO ❑ 1 certify that this report is accurate and 1 have used WAC 246-290-490 approved test methods and test equipment. 9322 14th Avenue South PSF Mechanical, Inc. Seattle, WA 98108-5102 T 206.764.9663 F 206.762.8381 - 0 0 75 psfmechanical.com FILE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field C py and conditions is acknowledged: By: Dater 115A7 - City of Tukwila BUILDING DIVISION REVISIONS No changes shall -be made to the scope of work without prior approval of Tukwita Building Division. I NOTE: Ravisions will require a new plan submittal 1 and may include additional plan review fees. SEA`WE PERMIT oEQU RED FOR: If - achanical (g-€iectrical ❑ Plumbing Uttas Piping City of Tukwila 6(.01_ ,,IG DIVISION Washington — Developmental Center 9725 East Marginal Way South, Seattle, WA 98108 i Employee galas V. Vendor track gates - --- Fence lines -• Trail El Boeing properly 0 General parking 01 Restricted parking ® Bus atop From Seattle Tacoma International Airport WANTAzts'?'- irt_4Al:w.g!d,`ift-t"k't5.14.:_sa-t'itraatea From uar 45 4' tiT >.5?91''y.'s. ' `",.`5k' ;ga.mv,�-_ ocki m`.F -Sista From Kent and Aubum Cade Fd(fr©p‘ tsc Z0(S tot, iv/ 1'v -c) v fi IP 7-€551(` ct Geri- 4- 7L REVIEWED FOR CODE COMPLIANCE APPROVED MAR 102011 City of Tukwila BUILDING DIVISION &ri oozs RECEIVED CITY OF TUKWILA FEB 22 2017 PERMIT CENTER PSFMechanicalk 11621 E Marginal Way S, Suite A Seattle, WA 98168 Tel (206) 764-9663 2 J J —J Q I— W Z z 2 T < 0 ch 2 u) z z J <16 J Z DO Q- -J O Z1 CO N D co c Z M J W LJJ H Ca O � 'w^^ U) a) Revisions Date e. Proj No: 41824 Scale: AS NOTED Drawn By: REM Checked By. TSG SITE COVER SHEET MSK -1 MECHANICAL LEGEND MECHANICAL LEGEND MECHANICAL LEGEND MECHANICAL LEGEND MECHANICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION WELDING PIPE IDENTIFICATION PIPE FITTINGS PIPING SPECIALTIES FIRE PROTECTION —LW— COMPRESSED AIR, PLANT X I Y PIPING MATERIAL CHANGE, X TO Y GATE OPEN CLOSED -04-/+4- VALVE, / O SPRINKLER HEAD, UPRIGHT, NEW ROOT OPENING, FINISH SYMBOL GROOVE ANGLE, -Cf ROOTH OF FILLING INCLUDED ANGLE ACID WASTE -I--I--I--I-- SCREWED FITTING OR AS SPECIFIED -a ANGLE GLOBE VALVE, ELEVATION / PLAN —ID— SPRINKLER HEAD, PENDENT, IN LINE, NEW FOR PLUG AND CONTOUR SYMBOL OF COUNTERSINK FOR PLUGWELD I I SLOT WELDS CC1 CONDENSATE RETURN (GRAVITY) 0 0 FLANGED FITTING GATE VALVE OUTSIDE SCREW AND YOKE SPRINKLER HEAD, PENDENT, OFFSET, NEW EFFECTIVE LENGTH OF WELD —DM— THROAT PITCH (CENTER TO F CHEMICAL FEED -4.---4F WELDED FITTING >0 GATE VALVE WITH HOSE CONNECTION V SPRINKLER HEAD, SIDEWALL, PENDENT, NEW CEOFTER IT SIZE, SIZE OR —q''QppJR� CHILLED WATER RETURN PIPE TEE, STRAIGHT {Q}/ GLOBE VALVE, OPEN / CLOSED V SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW WELDS STRENGTH FOR CERTAIN WELDS FIELD WELD SYMBOL --FCRW51— -\ R /- CHILLED WATER SUPPLY 101 PIPE TEE, OUTLET UP OR TOWARD Dfl BALANCE VALVE PLUG SPRINKLER HEAD, DRY PENDENT ARROW CONNECTING --{CRVI— , S (E P,}L-P, TOFARROWF LINE CORROSION RESISTANT VENT 18 I PIPE TEE, OUTLET DOWN OR AWAY PRESSURE REGULATING VALVE �� SPRINKLER HEAD, OVER AND UNDER SIDE �CRW}— '41 ,,( 161/, OR ARROW SIDE { 8} MEMBER OF JOINT CORROSION RESISTANT WASTE —,�— PIPE UNION PRESSURE RELIEF VALVE / SAFETY VALVE P X EXISTING SPRINKLER HEADS (TO REMAIN) l CDR TOWER (N COOLING FILTER RETURN I$t PIPE CROSS PETCOCK EXISTING SPRINKLER HEADS (REMOVE) WELD ALL AROUND �CTFS'1— COOLING TOWER FILTER SUPPLY �-+-SR PIPE ELBOW, 90' SHORT RADIUS tt1�1�� —i4YJ— BALANCE VALVE WITH METERING PORTS ELEMENTS IN THIS SYMBOL CTR COOLING TOWER RETURN ---41- PIPE ELBOW, 90' LONG RADIUS j SOLENOID OPERATED VALVE n FIRE HOSE CABINET / AREA REMAIN AS SHWN WHEN ARROW L ARE AND REFERENCE LINE �CTS'r— COOLING TOWER SUPPLY PIPE ELBOW, REDUCING *T 4 MOTOR OPERATED VALVEFDC Y FIRE DEPARTMENT CONNECTION, WALL TYPE REVERSED NUMBER OF SPOT OR PROJECTION WELDS DOMESTIC COLD WATER { )` PIPE ELBOW, 45' © SWING CHECK VALVE WITH FLOW 4FOCb. FIRE DEPARTMENT CONNECTION, YARD TYPE BASIC WELD OL 08111J FDC RAIL REFERENCE DEIONIZED WATER --hO PIPE ELBOW, TURNED UP OR TOWARD -1}/ UFT CHECK VALVE LJ FIRE DEPARTMENT CONNECTION, FLUSH TAIL (MAY 8E OMMIITED WHEN DISTILLED WATER I ET PIPE ELBOW, TURNED DOWN OR AWAY {4}/{l]- BALL VALVE, OPEN / CLOSED REFE FH FIRE HYDRANT - 2 HOSE OUTLET ENCE IS NOT USED �]-- FIRE HYDRANT - 2 HOSE OUTLET SPECIFICATIONS, PROCESS FIRE LINE, AHEAD OF ALARM VALVE 3 PIPE CAP SCREWED OR SOLDER JOINT —(Z— BUTTERFLY VALVE 4H FH AND PUMPER CONNECTION OR OTHER REFERENCE --IFORI— FUEL OIL RETURN D PIPE CAP, WELDED OR GROOVED D4T4 2 WAY CONTROL VALVE ® ASR AUTOMATIC SPRINKLER RISER 0 BACK WELD --00051— T NG FUEL OIL SUPPLY 11 BLIND FLANGE IS 3 WAY CONTROL VALVE WATER MOTOR GONG L FILLET WELD FOV FUEL OIL VENT PIPE PLUG —1ft— PLUG VALVE / STOP COCK ELECTRIC BELL PLUG OR SLOT WELD —1Tem NATURAL GAS REDUCING PIPE FLANGE C 4 FLOAT VALVE I'0 DRY PIPE VALVE I I SQUARE WELD —MGM— REFRIGERANT HOT GAS DISCHARGE PIPE REDUCER CONCENTRIC —,-kl— QUICK OPENING VALVEALV ALARM VALVE, WET H— OSPOT OR PROJECTION WELD ---EFPR'— CONDENSATE RETURN (PRESSURE) PIPE REDUCER ECCENTRIC - WYE STRAINER (WITH DRAIN VALVE) ❑M MONITOR SWITCH --WIT— STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) XE PIPE ANCHOR —1(g--- COOLING COIL CHILLED WATER FLOW SWITCH GENERAL -,HWS DOMESTIC HOT WATER SUPPLY f- PIPE HANGER —(I HEATING COIL _0.54 GROOVED COUPLING, GROOVED CAP `T" '2AV NEW WORK —ERWC'— DOMESTIC HOT WATER CIRCULATING SPRING HANGER AUTOMATIC AIR VENT (WITH DRAIN) -, THRUST BLOCK EXISTING WORK .— HWM HEATING WATER RETURN PIPE GUIDE -AMAV MANUAL AIR VENT (WITH DRAIN) —I -LW- POST INDICATOR VALVE, YARD ///////// }WN EXISTING TO BE REMOVED —0E11i% HEATING WATER SUPPLY 0 FLEXIBLE PIPE CONNECTION PRESSURE GAUGE WITH VALVE 0 WALL INDICATOR VALVE, PLAN / ELEVATION REVIEWED FOR 1i'I HIDDEN OR BELOW GRADE S INSTRUMENT AIR EXPANSION JOINT It THERMOMETER, LINE MOUNT O HALON SYSTEM AUTOMATIC DISCHARGE STATION CODE COMPLIANCE � CROSSING LINES, NO CONNECTION --ao-- INDIRECT DRAIN DIRECTION OF FLOW THERMOMETER, SEPARABLE WELL MOUNT n GE STATION HALON SYSTEM, MANUAL DISCHARGE�PI'„O ED APPROVED -4- CONNECTING LINES {TWT INDUSTRIAL WASTE SLOPE DIRECTION Of SLOPE, DOWN �IF TEST PLUG 1 2 WAY EARTHQUAKE BRACING V UEQUIPMENT MARK NUMBER —T— PG-1 LIQUID PETROLEUM GAS MB HOSE BIBB I 0 / ® AIR DROP, SIMPLEX / DUPLEX X 4 WAY EARTHQUAKE BRACING 1 0 2011 0. PUMP ---1Lp5 ;--- STEAM SUPPLY (LOW PRESS, 0-15 PSIG) NFHB NON FREEZE HOSE 81B8 6 / 6 AR OUTLET - HARD PIPE, SIMPLEX / DUPLEX MAR 4— INSULATED PIPE --1 MPSj— STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) $HH`IC PETE'S PLUG, WITH BALL VALVE ' —{T $— INSULATED PIPE WITH ELECTRIC HEAT TRACING -min— CONDENSATE RETURN (PUMPED) TRAP SEAL PRIMER VALVE CONTROLS POINT OF CONNECTION --{i'` PROCESS WATER WASTE FITTINGS —1ei9I-- BACKFLOW PREVENTER EMCS ENERGY MANAGEMENT CONTROL SYSTEM City of Tukwila —011Z— REFRIGERANT DISCHARGE ®Fp FLOOR DRAIN b FLOW METER, VENTURI TYPE MCC MOTOR CONTROL CENTER BUILDING DIVISION —MO— REFRIGERANT LIQUID ® FS FLOOR SINK U TRAP, FLOAT . MOTOR OPERATOR FIXTURES ® ®7D TRENCH DRAIN O VALVE BOX . PRESSURE TRANSMITTER DF DRINKING FOUNTAIN RWL 8,419400 WATER LEADER O WR WASTE RECEPTOR, ROOF —� ALROMATIC FLOW CONTROL VALVE (NUMBER INDICATES GPM)1_6_,d DIFFERENTIAL PRESSURE TRANSMITTER ❑ EWC ELECTRIC WATER COOLER © SPRINKLER LINE ® FFD FUNNEL FLOOR DRAIN . STEAM TRAP 1 RCUl ROMOTE CONTROL UNIT RECEIVED ❑ EWCH ELECTRIC WATER COOLER FOR HANDICAPPED —LSAARI� SANITARY WASTE BELOW GRADE OR FLOOR ORD (OFD) ROOF DRAIN (OVERFLOW DRAIN - ROOF) 0 VACUUM 0808 (IAB VAC) Q TEMPERATURE TRANSMITTER A CI 1 1 OF TUKWILER 0 LAV LAVATORY. ROUND COUNTER MOUNT — C 8N — SANITARY WASTE ABOVE GRADE OR FLOOR 1 00 SAND AND OIL INTERCEPTER OV VACUUM VACUUM OUTLET (LAB VAC) W 0 PIPED NQ -C] OPERATOR WITH POSI VE POSITIONER LAV LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT —�$TA1= STEAM SUPPLY "lWGD WALL CLEAN OUT El CLEANING OUTLET � P011008 RIEFSENSOR/TRANSMITTER FEB 22 2011 EWF SAFETY EYE WASH FOUNTAIN —{STS'r 0 FCO STORM DRAIN FLOOR CLEAN OUT 1<t3 I VALVE IN RISER (TYPE SPECIFIED) Q MAIN CONTROL AIR 20 PSIG u55 SERVICE SINK, WALL HUNG -NKr- VACUUM UCO CLEAN OUT, EXPOSED SS SERVICE SINK, FLOOR MOUNT - m VENT --1-,...4_ WASTE PIPING BEND PERMIT CENT 1.>31 SHOWER STALL AND FIXTURE —1N9— ARGON 1 \1 LATERAL (::!F D URINAL, WALL HUNG 1 I } SANITARY WE AND 1/BIH BEND C:-.) co WATER CLOSET, WALL HUNG PSFMechanical ISSUE FOR CONSTRUCTION 11621 E Marginal Way S, Suite A FEBRUARY 08, 2017 Seattle, WA 98168 Tel (206) 764-9663 SYM REVISION BY AAPRprEp DATE Wm REVISION WAPPROVED DAM BOE/NO® c/. ACCEPTABILITY ACC SPECIFICATION IS DESIGN NS AP/ROVED COFFMAN DATE 10.31.13 SUB'IrtIF MECHANICAL LEGEND AND ABBREVIATIONS CURRENT REVIyON . 32397 S'uBOL A DATE 02.08.17 ORIG BOEING 9-120 ASIC OFFICE MODERNIZATION J1131174-00 COFFMAN M.SOTURA 10.31.13 CHECKED 031 13 SHEET M4B A INSTALL SLM 280 DMLS MACHINE 32397 PSF M. KAMINSKY 02.08.17 LNLINILR TITLE INSTALL SLM 280 DMLS MACHINE BUILDING 9-120 MECHANICAL MASTER DEV. CENTER, WA APPROVED BY DEPT. DATE DHECKED JOB NO. J#131174-00 COMP N0. APPROVED OAT N0. 9-120—,M46 APPRavED AIR AMPLIFIER/DRYER FOR SINTERING MACH. 2"WASTE U O 0 4"VACUUM EXHAUST DN. 1 1/4' VENT LINES I 1" GATE VALVE . ai 411"..1I4\57.1 PRV-3000PM 0100-70 P9 3"CW DN 2"GAS ON W/ VALVE IN RISER 4" AIR D9 W/ VALVE IN RI R 0 14"0 VENT " 1'CW UP TO 2ND FL. (EXIST) 3/4" 2-1/2" 4' CONDENS I NG UNIT GAS 6 LIQ. LINE A REDUCING STATION 0 COND DRAT CD )6"OD 55-304 UP TO 2ND FL. 3" VENT 3 3" FUD FCO 0 u 3' O FUD 2V UP 36"3V UP 3 FD GOND. 'UMP 3/4" P TRAP TP ID RES IS ANT WAST UP 3 W UP TO SPRINKLER 1)5"A UP TO 2ND FL. N 125# PSI COMPRESSED Al 3/4"CA TO COL. E4 3/4" I25# PSI COMP. AIR - HWC C 3/4 PSI COMP. Al ACID RESISTANT WAS,t1 FCO 0 2" SAN UP MOIRE TEST 134 19— I/O" STRAIN GAG 140 3/4"6 SHOP 135 PARTIAL PLAN VIEW SCALE: 1/8"= 1'-0" O 0 0 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 102017 4 City of Tukwila BUILDING DIVISION 0 LEGEND — HW- - CW- - A - - HPA - - HWC- - SAN - - IW — — AR — — CD — A °FC0 FD FUD Y HOT WATER, DOMESTIC COLD WATER, DOMESTIC COMPRESSED AIR 125# HIGH PRESSURE COMPRESSED AIR HOT WATER CIRCULATING, DOMESTIC SANITARY WASTE INDUSTRIAL WASTE ARGON CONDENSATE DRAIN VENT AIR OUTLET, HARD PIPE, DUPLEX AIR DROP - HOSE, DUPLEX FLOOR CLEAN OUT FLOOR DRAIN FUNNEL DRAIN 2 -WAY EARTHQUAKE BRACING, SEE 4 -WAY EARTHQUAKE BRACING, SEE POINT OF CONNECTION 1 M111 16504 GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES CONNECT NEW 1/2" COMPRESSED AIR (CA) LINE TO EXISTING 1" PROVIDE NEW BRANCH VALVE. CL OF EXISTING 1" LINE IS 7'-3" A.F.F. RUN NEW CA LINE TO AIR DRYER. SEE DETAIL -2 SHEET M544 AND FLOW DIAGRAM SHEET M544 [>, 2 CONNECT NEW 1/2" CW LINE TO EXISTING. CONNECT TO NEW FILTER FLOOD STATION WITH NEW REDUCED PRESSURE BACK FLOW PREVENTER. RUN NEW LINE ON SURFACE TO SINK. SEE DETAIL -2 SHEET M544 AND FLOW DIAGRAM SHEET M544. 2> PROVIDE NEW 3/4" REDUCED PRESSURE BACK FLOW PREVENTER. (RPBFP). RECEIVED CITY OF TUKWILA FEB 22 2011 PERMIT CE ISSUE FOR CONSTRUCTION FEBRUARY 08, 2017 KEY PLAN /\ SCALE: NONE 1_ J PgF 8_ 4_ 0 4' 8' 16' PSFMechanical 11621 E Marginal Way S, Suite A Seattle, WA 98168 Tel (206) 764-9663 -- SCALE: 1/8"= 0" REVISIO9 0 9-120 RENOVATION RECORD DRAWING REMOVE DRINKING FOUNTAIN COMBINED DLR WITH OLD 10111 ADD AIR DROPS 416054201-02 J#16054201-02 6382422 R1 COFFMAN COFFMAN HARR S.RUDELL APPROVED DATE M. SOTURA M. SOTURA RWS 07.12.07 06.16.08 02.13.08 07.24.08 SYM V REVISION RELOCATE ACAL/ASIC IAB ADD AIR DUPLEX DROPS TO SHOP 7-33 GATEWAY MOVE TO 9-120 INSTALL SLM 280 DMLS MACHINE 12370682 20254443 32397 BT M.WONG 0.STRICKER M.WONG PSI APPROVED RWS D.STRICKER M. KAMINSKY DATE 01.05.12 04.28.16 10.20.16 02.08.17 4464 HARR 05.05.09 e)LAMPEZAWe P ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN 1. 'A M. SOTURA DATE 05.23.07 05.23.07 SUBTITLE PLUMBING PIPING PLAN - FIRST FLOOR CURRENT REVISION 32397 SYMBOL ` ' DATE 02.08.17 WAILER NECKED APPROVED APPROVED TOLE MECHANICAL MASTER INSTALL SLM 280 DMLS MACHINE BUILDING 9-120 COL. F -K/1-5 DEV. CENTER, WA SHEET 1M111 JOB N0. 16054201-02 COMP NO. MC NO. 09-120-2011 0 0 0 0 0 STRAIN GAGE {(2 140 STRAIN GAGE jjl 141 0 0 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 10 2017 O City of Tukwila BUILDING DIVISION PARTIAL PLAN VIEW SCALE: 1/8"= 1'-0" 0 0 LEGEND — HW— HOT WATER, DOMESTIC — CW— COLD WATER, DOMESTIC — A — COMPRESSED AIR — HPA — 125# HIGH PRESSURE COMPRESSED AIR — HWC — HOT WATER CIRCULATING, DOMESTIC — SAN — SANITARY WASTE — IW — INDUSTRIAL WASTE — AR — ARGON — CD — CONDENSATE DRAIN - - V- - - VENT • AIR OUTLET, HARD PIPE, DUPLEX AIR DROP - HOSE, DUPLEX 0FCO FLOOR CLEAN OUT FD FLOOR DRAIN FUD FUNNEL DRAIN 2 -WAY EARTHQUAKE BRACING, SEE 4 -WAY EARTHQUAKE BRACING, SEE ▪ POINT OF CONNECTION GENERAL NOTES REFERENCE DRAWINGS 1M111I M504 CONSTRUCTION NOTES ARGON MANIFOLD SEE DETAIL -1 SHT M544 NEW 1/2" ARGON PIPE TYPE K COPPER TUBE. UNE MOUNT ON EXISTING STRUT ABOVE CCA LINE. CL OF AR PIPE 7'-5" A.F.F. NEW AR LINE DROP LOCATION. SEE DIAGRAM SHT M544 RECEIVED CITY OF TUKWILA FEB 22 2017 PERMIT CENTER PSF PSFMechanicali ISSUE FOR CONSTRUCTION FEBRUARY 08, 2017 11621 E Marginal Way S, Suite A Seattle, WA 98168 Tel (206) 764-9663 8' 4' 0 4' 8' 16' - SCALE: 1/8"=1'-0" SYM A REVISION INSTALL SIM 280 DMLS MACHINE 32397 BY PSF APPROVED DATE REVISION or APPROVED DATE M. KAMINSKY 02.08.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION 15 APPROVED BY OEPT. DATE APPROVED DRAWN COFFMAN CHECKED M. SOTURA D TE 05.23.07 05.23.07 SUBTITLE PROCESS PIPING PLAN - GAS - FIRST FLOOR CURRENT REVISION 32397 SYMBOL A GATE 02.08.17 NUINLLH CHECKED APPROVED APPROVED 1ITLE MECHANICAL MASTER INSTALL SLM 280 DMLS MACHINE BUILDING 9-120 COL. F -K/1-5 DEV. CENTER, WA SHEET 1M21 1 JOB NO. 16054201-02 COMP NO. DWG NO. 09-120-1M211 BRONZE STRAINER BALL VALVE GATE VALVES TEST COCK (TYP)� / OR BALL VALVES W REDUCER •.�� , .�I REDUCER '1111! SUPPLY 1/2" AIR GAP PIPE TO FLOOR DRAIN 1/2" OUTLET BACKFLOW PREVENTER, WATTS 909 SERIES OR EQUAL 1. TO BE INSTALLED IN A CONTINUOUS PRESSURE WATER SUPPLY. 2. CAN BE INSTALLED HORIZONTALLY OR VERTICALLY. 3. WATER SPILLAGE WILL LIKELY OCCUR. AN AIR GAP WITH DRAIN LINE MAY BE INSTALLED AS REQUIRED. IN A VERTICAL INSTALLATION AN ELBOW IS ALSO NECESSARY AND FLOW MUST BE "UP". 4. DESIGNED TO BE INSTALLED AT CROSS CONNECTIONS SUBJECT TO HIGH HAZARD BACK PRESSURE OR BACK SIPHONAGE. 5. VERY HIGH PRESSURE DROP. 6. ACCESS & CLEARANCE SHALL BE PROVIDED FOR REQUIRED TESTING, MAINTENANCE, & REPAIR: INCLUDING A MINIMUM OF 1'-0" BETWEEN LOWEST PORTION OF ASSEMBLY, AND FLOOR OF PLATFORM. ASSEMBLIES INSTALLED MORE THAN 5'-0" ABOVE FLOOR SHALL BE PROVIDED WITH A PERMANENT PLATFORM CAPABLE OF SUPPORTING A TESTER OR MAINTENANCE PERSON. 3/4" RPBFP-9-120 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER DETAIL( 1M111 M544 SCALE: 1" = 1'-0" ALL ELECTRICAL COMPONENTS TO BE UL OR ETL LISTED ALARM PANEL 1/2"- �O v AUTOMATIC 1/2" SWITCHOVER AIR MANIFOLD _ 24" PIGTAILS (3 TYP) 1/2" FPT LOCKING 150# BALL VALVE WATTS #B-6400LL/#B-6000LH OR EQUAL 1/2" X 4" PIPE NIPPLE KINDORF C-105 PIPE CLAMP OR EQUAL FLOOR 45• 3/8" X 3/8" X 1/2" REDUCING TEE 3/8" STREET ELBOW (2 PLCS) 10MM SOCKET QUICK DISCONNECT (2 PLCS) WALL OR STRUCTURE (REF) WALL BOARD ANCHOR, SCREW & WASHER MOLLY BOLT OR EXPANDING TYPE ANCHOR (2 PLCS) B -LINE B-22 CHANNEL OR EQUAL NOTES 1. MSS ASSY: STDP09 2. ALL FIGS MALL IRON STANDARD DUPLEX AIR DROP - WALL 1/2" BRANCH WITH 10MM SOCKETS DRIED AIR SCALE: NONE CAF -9-120-1 CAF 9 120 2 L 'JARGON SYSTEM 1/2" 91010 - WITH MANIFOLD COPPER WITH / J \ BRASS FITTINGS 1 M2111 M544 AIR DRYER 1M111 (544 Tyra 10MM QUICK 1 CONNECTORS PRESSURE REGULATOR AND FLOOR 10MM QUICK CONNECTOR 1/2" ARGON TYPE K COPPER PIPE SLM280HL CHILLER 9 MOUNTED 1M11�4 REPLACE EXISTING N2 MANIFOLD WITH NEW AR MANIFOLD 0 mk io w m EXISTING ELECTRICAL BOX Lc 30" BETWEEN ELECTRICAL BOX AND EXHAUST VENT za Led `F2 ARGON (AR) PIPING DIAGRAM (-3- SCALE: NTS EXISTING 1/2"HW & 1/2" CW DN TO DOUBLE COMPARTMENT SINK CAPPED OFF ON DOUBLE COMPARTMENT SINK u it 9 9 9 CW TO FILTER FLOODING STATION DIAGRAM 1 M211 M544 4 SCALE: NTS 1M111 M544 FLOODING STATION 1M111 M544 ,e. HOSE TO SII}EV FLOW DIAGRAM 8 SCALE: NTS 1M111_,1544 CODE 1M111944 FILTER FLOODING STATION Thk 1/2" 44 BFP RPBFP-9-120 k_ HOSE TO SINK FILTER FLOODING STATION SCALE: NTS 1M111944 ARGON (AR) AND COMPRESSED AIR REQUIREMENTS PRESSURIZED AIR AND INERT GAS REQUIREMENTS PRESSURIZED AIR (AIR IS USED IN THE OPTICAL CHAMBER SO THIS PURITY AND DEWPOINT ARE CRITICAL FOR PROPER MACHINE OPERATION) *PURITY CLASS ACCORDING TO ISO 8573-1:2010 1-4-1 (BEFORE COMPRESSED AIR DRYER) 'FLOW RATE, AVERAGE: 15 L/MIN *FLOW RATE, MAX.: 100L/MIN WITHOUT NITROGEN GENERATOR 500L/MIN WITH NITROGEN GENERATOR 'OPERATING PRESSURE: 6.0 BAR ARGON OR NITROGEN *PURITY CLASS ACCORDING TO DIN EN ISO 14175 GROUP L1:4.6 (99.996% OR HIGHER) *FLOW RATE, AVERAGE: 4 TO 6 L/MIN *FLOW RATE, MAX.: 80L/MIN (17 MINUTE PURGE) *OPERATING PRESSURE: 6.0 BAR *PRESSURE REDUCER FOR GAS BOTTLE: E.G. ERL GMBH, PRESSURE REDUCER ARGON 10BAR, 30M3/H, ORDER -NR.: 31.1.10.400 (OR COMPARABLE) ARGON (AR) AND COMPRESSED AIR SPEC 6 SCALE: NTS 1M111 M544 CONSTRUCTION NOTES CONNECT NEW CA LINE TO EXISTING 1" PROVIDE NEW BRANCH VALVE. CL OF EXISTING 1" LINE I5 7'-3" A.F. RUN NEW CA LINE TO AIR DRYER. SEE DETAIL -2 SHEET M544 AND FLOW DIAGRAM SHEET M544. 5/8" 0.D. TUBE CLAMP COPPER PLATED SUPER STRUT CTA -701 ,II 1/2" TYPE K COPPER TUBE 1-5/8"x 1-5/8" CHANNEL, SUPER STRUT A-1200 OR EQUAL. ANCHOR TO WALL. 1/2" IPSx6" BRONZE NIPPLE 3/4"x 1/2" BRONZE BRUSHING H 1101 1111 11 11 11 MUM II ARGON MANIFOLD MALE CONNECTOR, 5/8" 0.D. TUBExi" MPT. BRASS BILOK DCT -10-8-8. 1/2" BALL VALVE, BRASS BODY, 3 PIECE, S.S. BALL, WORCESTER #1/2-416 T 3E. M544 8 1M111 M544 ARGON MANIFOLD DETAIL (( 1M111 M544 SCALE: NONE ARGON GAS HIGH PRESSURE AUTO SWITCHOVER MANIFOLD TAG SYSTEM -APPLICATION SERVES MANUFACTURER -MODEL PERFORMANCE DESCRIPTION NOTES AR9 120 1 ARGON REGULATOR AND CONTROL MANIFOLD SLM280 DMLS MACHINE HARRIS PRODUCTS SG960BR-1R-2L-580 80UMIN AT 6.0 BAR LEAD FREE;WITH REPLACABLE SEATS, PROVIDE WITH 909AG-4 1-1/4" AIR GAP 1. BOTTLE CONFIGURATION 1 -RIGHT AND 2 -LEFT. REDUCED PRESSURE BACK FLOW PREVENTER TAG SYSTEM•APPLICATION SERVES MANUFACTURER•MODEL PERFORMANCE DESCRIPTION NOTES RPBFP-9-120 BACK FLOW PREVENTER FILTER FLOOD STATION WATTS LF909-3/4" TEMP RANGE 33°F-140: MAX WORKING PRESSURE 175 P51 12.5GPM AT 7.5FPS 13PSI DELTA P LEAD FREE;WITH REPLACABLE SEATS, PROVIDE WITH 909AG-4 1-1/4" AIR GAP 1.0 INSTALL IN CW LINE SERVING FILTER FLOOD STATION COMPRESSED AIR FILTERS TAG SYSTEM -APPLICATION SERVES MANUFACTURER -MODEL PERFORMANCE DESCRIPTION NOTES CAF -9-120-1 COMPRESSED AIR SLM280 DMLS MACHINE AIR DRYER WILKERSON F16-02.000 1/2" STAGE -1 5 MICRON AIR FILTER 4-17.5 SCFM CONTINOUS STANDARD UNIT WITH MANUAL DRAIN; FILTER UP TO 80.4 SCFM 5 MICRON 1.0 INSTALL AT THE INLET OF NEW KAESER AIR DRYER E� �L� ViLD CFGR AIR i V`f a SLM280 DMLS MACHINE AIRRggBE `�`f■/L WOK[ QN, o ^^ CK00 (1 112" STAGE -2 0.01 PPM AIR FILTER , 17.5SCFMCONTINOUS STANDARD UNIT WITH MANUAL DRAIN; UPT TO 48 SCFM 0.01 PPM 1.0 INSTALL AT THE INLET OF NEW KAESER AIR DRYER APPROVED MAR 10 2017 City of Tukwila REVISION INSTALL SLM 280 DMLS MACHINE 32397 BY PSF APPROVED DATE SYM RENSION BY APPROVED DATE M. KAMINSKY 02.08.17 ce;i__AWISIEA/AW' ID! GA � � L IOF Mwawm, SPECIFICATION SAN APPROVED APPROVED BY DEPT. DATE ITV OF TUKWILA FEB 22 2017 PERMIT CENTER ISSUE FOR CONSTRUCTION FEBRUARY 08, 2017 Crop PSFMechanicai 11621 E Marginal Way S, Sufte A Seattle, WA 98168 Tel (206) 764-9663 N H MBL DATE 12.02.14 12 02.14 SUBTITLE HVAC DETAILS ,CURREMT REVISION 32397 SYMBOL DATE 02.08.17 ENUINLEN MBL 12.02.14 CHECKED CEL 12.02.14 APPROVED APPROVED TITLE MECHANICAL MASTER INSTALL SLM 280 DMLS MACHINE BUILDING 9-120 SHEET M544 JOB NO. 21067 COMP N0. SEATTLE, WA °WG TV. 9-120-M544 /• ( SENT ES-LF909S For Health Hazard Applications Job Name Boeing 9-120 SLM Job Location Seattle, WA Engineer Approval PSF Mechanical LEAD FREE* Series LF909 Contractor Approval Contractor's P.O. No 4vEJ) Duane Ho','e --.� PSF Mechanical TUKWILA Assemblies PUBLIC WOR , 40, 50mm) Series LF909 Reduced Pressure Zone Assemblies are designed to provide superior cross -connection control protection of the potable water supply in accordance with national plumbing codes and containment control for water authority requirements. This series can be utilized in a variety of installations, including health hazard cross -connections in plumbing systems or for containment at the service line entrance. The LF909 features Lead Free* con- struction to comply with Lead Free* installation requirements. With its exclusive, design incorporating the "air-in/water-out" principle it provides maximum relief valve discharge during the emergency conditions of combined backsiphonage and backpressure with both checks fouled. Model LF909QT, standardly furnished with full port, resilient seated and Lead Free* cast copper silicon alloy ball valve shutoffs. Sizes 3/4" tee handles. Features • Modular design • Replaceable seats • Compact for installation ea • Horizontal or vertical (up o • No special tools required f Specifications City of Tukwila UILDING DIVISION Model LF909M1QT-S 1'/:" (40mm) n• l an. mm s u o's ave REVIEWED by RON MARSON 2.16.2017 Job # 41824 RECEIVED Ball Valve TesCITY OF TUKWILA First Chec Module ssembly BAR 0 S 2017 IT CENTER PSF Mechanical, Inc. ® No Exception Taken ,e El Reviewed With Comments - drly M rtSst 11 ticcrPr Notations Revel varve — Thie review has been for general content only. LJ3gmbly 'r SES does not imply acceptance, nor relieve submitter from compliance with all requirements of the contract documents or any laws or regulating authorities. A Reduced Pressure Zone Assembly shall be installed at each cross -connection to prevent backsiphonage and backpressure of hazardous materials into the potable water supply. The assembly shall consist of a pressure differential relief valve located in a zone between two positive seating check valves. Backsiphonage pro- tection shall include provision to admit air directly into the reduced pressure zone via a separate channel from the water discharge channel, or directly into the supply pipe via a separate vent. The assembly shall be constructed using Lead Free* cast copper sili- con materials. The Lead Free* reduced pressure zone assembly shall comply with state codes and standards, where applicable, requiring reduced lead content. The assembly shall include two tightly closing shutoff valves before and after the assembly, test cocks and a protective strainer upstream of the No. 1 shutoff valve. The assembly (specify Model LF909 for temperatures up to 140°F (60°C) or Model LF909HW for temperatures up to 210°F (99°C)) shall meet the requirements of ASSE Std. 1013; AWWA Std. C-511-92 CSA B64.4; FCCCHR of USC Manual Section 10. Listed by IAPMO (UPC). SBCCI (Standard Plumbing code). The assembly shall be a Watts LF909QTS or LF909QTSHW. Water Outlet R.P.Zone Second Check Module Assembly trOefiRECTION LTR# 1 Now Available WattsBox Insulated Enclosures. For more information, send for literature ES -WB. *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Watts product tac specifications in U.S. cusWatryts units and mnigh are geior te and are provideddesign, forreference only. For se measurements, TIES® please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. -1)11-002-g Models Suffix water conditions NOTICE ck modules for hot and harsh The installation of a drain line is redommended. When installing a drain line, an air gap is necessary. Materials Body: Lead Free* Cast Copper Silicon Alloy Check Seats: 909 Celcon® Relief Valve Seats: Stainless Steel 909HW Test Cocks: Lead Free* Cast Copper Silicon Alloy Celcon@ is a registered trademark of Celanese, Limited 3/" - 1" (19 - 25mm) 909 -NPT Female threaded body connection • body connection Standards AWWA C-511-92 FCCCHR of USC Manual Section 10 IAPMO (UPC), SBCCI (Standard Plumbing code) Approvals Listed by IAPMO Rte' ® �o Listed by SBCCI 1013 c 864.4 us $Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. (QT and S Models) Horizontal and vertical "flow -up" approval on 3/4" (20mm) and 1" (25mm) sizes (model LF909QT). Pressure — Temperature Temperature Range: 33°F - 140°F (0.5°C - 60°C) continuos, 180°F (82°C) intermittent Maximum Working Pressure: 175psi (12.1 bar) Series LF909HW: Temperature Range: 33°F - 210°F (0.5°C - 99°C) Maximum Working Pressure: 175psi (12.1 bar) How it Operates The unique relief valve construction incorporates two channels: one for air, one for water. When the relief valve opens, as in the accompa- nying air-in/water-out diagram, the right-hand channel admits air to the top of the reduced pressure zone, relieving the zone vacuum. The chan- nel on the left then drains the zone to atmosphere. Therefore, if both check valves foul, and simultaneous nega- tive supply and positive backpressure ry develop, the relief valve uses the air- WATER OUT in/water-out principle to stop potential backflow. AIR IN Dimensions — Weights When installing a drain line use 909AG series Air Gaps on Series 909 backflow preventers. tt909EL series elbows are for air gaps on backflow preventers in vertical installations. Series 909AG Air Gaps Model LF909QT-S E Model LF909QT 909 DRAIN OUTLET DIMENSIONS WEIGHTS Iron Body Sizes Sizes A B No. Desc. in. mm in. mm in mm in. mm lbs. kg. 909AG-C Air Gap %,1 19,25 1 25 .31/4 83 4'% 124 1'/: .7 909EL-C Elbowtt 3/4,1 19,25 — — 2'% 60 2'% 60 '% .2 909AG-F Air Gap 11/4-2 32-50 2 50 4% 111 63/4 171 31/4 1.5 909EL-F Elbowtt 11/4-2 32-50 — — 35 92 33/4 92 2 .9 Model LF909QT-S E Model LF909QT / Capacity As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research of the University of Southern California lab tests. kPa psi 110 16 83 12 55 8 28 4 .-.• • '/:' (20mm _____ ._.moi _..W11_.I1111___.__.a ----. i• •••-••• MEMS■ I•�•••�••• ....■ I........■ 0 0 5 10 15 19 38 57 5 7.5 10 1.5 2.3 3.0 20 76 25 95 15 4.6 30 114 35 gpm 133 Ipm 20 fps 6.1 mps kPa psi 138 20 103 15 69 10 35 5 0 20 30 40 50 60 70 80 90 100 gpm 0 38 76 114 152 190 228 266 304 342 3 0 Ipm 5 7.5 10 15 20 fps 1.5 2.3 3.0 4.6 6.1 mps kPa psi 138 20 103 15 69 10 35 5 kPa psi 138 20 103 15 69 10 35 5 kPa psi 138 20 103 15 69 10 35 5 2" (50mm) 0 1" (25mm 5 10 15 20 25 30 35 40 45 50 55 60 gpm 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 20 fps 1.5 2.3 3.0 4.6 6.1 mps 1'/::" (40mm) 0 0 10 20 30 0 38 76 114 5 1.5 40 50 152 190 7.5 2.3 0 25 50 75 100 125 150 175 200 gpm 95 190 285 380 475 570 665 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 60 70 80 90 10 gpm 228 266 304 342 38 Ipm 10 15 fps 3.0 4.6 mps LF909QT, LF909QT-S SIZE (DN) DIMENSIONS WEIGHT A As B C D E Es L P QT QT -S ,11 I u I 11 1 1 "1 1 1 I p 1 1 1 . 1 1 I 1 1 1, 1 IS. . 3/e" 14% 365 18%6 459 83/ 222 4 102 43/. 121 63% 171 103/6 259 75/6 186 3% 98 14 6.4 15.6 7.1 1%."M1 181/2 470 233'16 595 115% 295 51/2 140 61/2 165 7%2 191 123/6 310 10% 264 51 133 40 18.1 42.8 19.4 11/2"M1 19 483 24'/6 619 115% 295 51/2 140 61/2 165 71/2 191 125% 321 10% 264 51/4 133 40 18.1 44.0 20.0 2"M1 191/2 ` 495 2515/6 659 115% 295 51/2 140 61/2 165 734 197 1315/6 354 10% 264 51/4 133 40 18.1 47.4 21.5 Subscript = strainer model V WWA1-rs" A Watts Water Technologies Company USA: Tel: (978) 689-6066 • Fax: (978) 975-8350 • Watts.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • Watts.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • Watts.com ES-LF909S 1421 © 2014 Watts City of Tukwila Department of Community Development February 27, 2017 AMANDA MOORE 11621 E MARGINAL WAY S TUKWILA, WA 98168 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG17-0025 BOEING #9-120 - 9725 E MARGINAL WAY S Dear AMANDA MOORE, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development pepmit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: PW - PG DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. 1) Submit cut sheet for the proposed RPPA backflow and circle the device to be installed. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. PG17-0025 6300 Southcenter Boulevard Suite #100 ® Tukwila Washington 98188 ® Phone 206-431-3670 • Fax 206-431-3665 t'ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0025 DATE: 03/06/17 PROJECT NAME: BOEING #9-120 SITE ADDRESS: 9725 E MARGINAL WAY S Original Plan Submittal Revision # L before Permit Issued X Response to Correction Letter # 1 Revision # 1' after Permit Issued DEPARTMENTS: Building Division ❑ As AuX, Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 03/07/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: ❑ Approved with Conditions , Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 04/04/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only /6 CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ 111-irStaff Initials: 12/18/2013 PERMIT COORD COPY: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0025 DATE: 02/22/17 PROJECT NAME: BOEING #9-120 SITE ADDRESS: 9725 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural El Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 02/23/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required k (corrections entered in Reviews) Notation: 1, Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 03/23/17 E REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: :17": t / Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila:wa.us 1 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 3/6/17 Plan Check/Permit Number: PG17-0025 D Response to Incomplete Letter # Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Boeing #9-120 Project Address: 9725 E Marginal Way S Contact Person: Ron Marson Phone Number: 206.764. 9663 Summary of Revision: Attached Watts Backflow Preventer that is to be used on the project For review. Intended Device has been circled with clouds for Clarification. RECEIVED CITY OF TUKWILA MAR 0.6 2017 PERMIT CENTER Sheet Number(s): Additional information as requested. "Cloud" or highlight all areas of revision including ate o revil )n Received at the City of Tukwila Permit Center by: O Entered in TRAKiT on \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: P S F MECHANICAL INC Hoene Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 A-7, Index Help Nlv L&1 Workplace Rights Trades & Licensing P S F MECHANICAL INC Owner or tradesperson Principals REYNOLDS, JAMES P, PRESIDENT READ, ANDREW A, PRESIDENT BEARDSLEY, WARREN SCOTT, SECRETARY CRITCHLOW, JAMES D (End: 09/27/2011) Doing business as P S F MECHANICAL INC WA UBI No. 601 318 369 11621 E Marginal Way S Suite A SEATTLE, WA 98168 206-764-9663 KING County Business type Corporation Governing persons ANDREW AARON READ JAMES P REYNOLDS; JIM BEARDSLEY; WARREN S BEARDSLEY; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PSFMEI*090NZ Effective — expiration 08/09/1991-10/05/2017 Bond Travelers Cas & Surety Co Bond account no. 105975899q $12,000.00 Received by L&I Effective date 03/13/2014 03/13/2014 Expiration date Until Canceled Bond history Insurance Liberty Mutual Fire Insurance Policy no. TB2Z91452741026 Received by L&I $1,000,000.00 Effective date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601318369&LIC=PSFMEI*090NZ&SAW= 3/14/2017 P S F MECHANICAL INC 09/28/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 11-2-02060-9 Complaint filed by SICKLESTEEL CRANES INC Complaint date 10/18/2011 L&I Tax debts 10/01/2016 Expiration date 10/01/2017 Open Complaint against bond(s) or savings 08973126 Complaint amount $6,429.61 No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 848,535-00 Account is current. Doing business as PSF MECHANICAL INC Estimated workers reported Quarter 4 of Year 2016 "Greater than 100 Workers" L&I account representative T3 / KAYLENE MONIER (360)902-6627 - Email: BRKB235@Ini.wa.gov Track this contractor I r Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/10/2014 Inspection no. 317399160 Location 9322 14 Avenue S Seattle, WA 98108 Violations Inspection results date 04/01/2013 Inspection no. 316732031 Location 600 University Seattle, WA 98101 No violations Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601318369&LIC=PSFMEI*090NZ&SAW= 3/14/2017