Loading...
HomeMy WebLinkAboutPermit PG17-0026 - SEATTLE METROPOLITAN CREDIT UNION - ROUGH-IN BREAKROOM SINKS, LAVATORIES, SINGLE USE FILTERSSEATTLE METROPOLITAN CREDIT UNION 17250 SOUTHCENTER PKWY SUITE 132 PGI 7-0026 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 7888920020 Permit Number: 17250 SOUTHCENTER PKWY 132 Issue Date: Permit Expires On: SEATTLE METROPLITAN CREDIT UNION PG 17-0026 3/15/2017 9/11/2017 Owner: Name: Address: Contact Person: Name: WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE, WA, 98006 JOE PAPERNIK Address: 11432 47TH AVE NE , MARYSVILLE, WA, 98271 Contractor: Name: CITY PLUMBING INC Address: 11432 47TH AVE NE , MARYSVILLE, WA, 98271 License No: CITYPI*955KJ Lender: Name: Address: Phone: (360) 661-5568 Phone: (360) 454-0481 Expiration Date: 8/1/2018 DESCRIPTION OF WORK: DEMO OLD COMMERCIAL KITCHEN PLUMBING. ROUGH -IN 2 BREAKROOM SINKS WITH INST-HOTS. CHANGE OUT TWO EXISTING LAVATORIES AND INSTALL SINGLE USE FILTERS FOR COFFEE MAKERS. Valuation of Work: $10,500.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $190.52 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 kk.41Permit Center Authorized Signature:(1.7 TJl/14) Dam: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume • give authority to violate or cancel the provisions of any other state or local laws regulating construction or he performance of work. I am authorized to sign and obtain this development per./it and agree � the conitions attached to this permit. Signature: Print Name: Date: g`_ 1S-20/7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 15: Prior to permit issue the applicant shall fill out King County Non -Residential Sewer Use Certification form and list all the new plumbing fixtures to be installed. Do not list fixtures to be replaced in kind. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. TG 00) co Project No. Date Application Accepted: ! .7 ( 7 Date Application Expires: q -)---t 7 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 17250 Southcenter Blvd Suite Number: 132 Floor: 1st & 2nd New Tenant: m Yes El ..No Tenant Name: Seattle Metropolitan Credit Union PROPERTY OWNER Name: Joe Papernik Name: WIG Properties LLC City: Marysville State: Wa Zip: 98271 Address: 4811 134th Place SE Email: jpapernik@cityplumbing.org City: Bellevue State: Wa Zip: 98006 CONTACT PERSON — person receiving all project communication Name: Joe Papernik Address: 11432 47th Ave NE City: Marysville State: Wa Zip: 98271 Phone: (360) 661-5568 Fax: (360) 454-0485 Email: jpapernik@cityplumbing.org PLUMBING CONTRACTOR INFORMATION Company Name: City Plumbing Inc. Address: 11432 47th Ave NE City: Marysville State: Wa Zip: 98271 Phone: (360) 661-5568. Fax: (360) 454-0485 Contr Reg No.: CITYPI*955KJ Exp Date: Tukwila Business License No.: BUS -0993653 Valuation of Project (contractor's bid price): $ 10,500 Scope of Work (please provide detailed information): Demo old commercial kitchen plumbing, Rough -in 2 break -room sinks with inst-hots, Change out two existing lavatories, and install single use filters for coffee makers. Building Use (per Int'I Building Code) - Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer H:\Applications\Fotms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9.11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap 2 Sinks 2 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) I Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory 2 Urinal Water heater and/or vent Repair or alteration of drainage or vent piping I Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJU ' HE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: Joe Papemik T: Mailing Address: 11432 47th Ave NE H:\Applications\Forms-Applications On Line\201 I Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: 02/27/2017 Day Telephone: (360) 661-5568 Marysville Wa 98271 City State Zip Page 2 of 2 DESCRIPTIONS I PermitTRAK ACCOUNT QUANTITY I PAID $190.52 PG17-0026 Address: 17250 SOUTHCENTER PKWY 132 Apn: 7888920020 $190.52 Credit Card Fee $5.55 Credit Card Fee R000.369.908.00.00 0.00 $5.55 PLUMBING $177.86 PERMIT FEE R000.322.100.00.00 0.00 $109.14 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE• R000.322.103.00.00 0.00 $35.57 TECHNOLOGY FEE $7.11 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10970 R000.322.900.04.00 0.00 $7.11 $190.52 Date Paid: Thursday, March 02, 2017 Paid By: JOSEPH PAPERNIK Pay Method: CREDIT CARD 09706G Printed: Thursday, March 02, 2017 11:39 AM 1 of 1 CRSYSTEMS INSPECTION RECORD Retain a copy with permit %1%`0626 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Prroject: S6211-1-14 C t'lr Typajof Inspection: rteia►'✓i 13i1•b- M4L ei2W Address: 72S -Z) cvnicaiw ii i,d'' Date Called: Special Instructions: •/ 32 Date Wanted: Requester:CIA Y Phone No: 36»- 6.1i-946/1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be - paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PG17 0311401 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: s 3771 a M , C/2efosT CRRi) Type of Inspection: Rstk -Iii PJ W 1'tii 11 Address: '7250 g'oopeap:iR Pi4WY Date Called: Special Instructions: /3t- Date Wanted: 3 .-30 -17 Ip.m. ca_my Phone No: 3620- C,a Sit- 9Y6 ,i4 Approved per applicable codes. E1 Corrections required prior to approval. COMMENTS: v/J7gk PR,60110 pktho B/W-- Inspector: as Date: 3 --(7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ?S R! REVISIONS. No changes shalt be made to the scope of wok withol.t prior approval of Tukwila Building Division. NOT`: RCl ;ions tvill require a new plan submittai and may include additional plan review fees. SCOPE OF WORK FELE COPY Permit RI®. ' 004 Plan review :fo sroval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code o • rdinance. Receipt of approved Field t► • py and on eons is acknowledged: By: Date: % r 20/ 7 City of Tukwila BUILDING DIVISION Symbols Legend: a u REVIEWED FOR CODE COMPLIANCE APPROVED MAR 10 2011 ktil City • of Tukwila BUILDING DIVISION Key Notes: 0 t; 1 SEFrAr:nTE PE^MIT L A QUIRED FOR: ^�ehanicai LL>��'' i ;ctricai 0 P mbing Gas Piping City of Tukwila Cl.lit_DINO DIVISION MI= ELECTRICAL PANEL NO DESIGNAOON - EXISTING D = DEMOLISH c> ND THIS AREA UNLESS OI1ERMISE INDICATED. O RO NE COSTING STOREFRONT SYSTEM A5 NECESSARY 10 AHXXIMMO0ATE NEW AUTOMATIC TELLER MACHINE REFER TO FLOOR PLAN FOR NEW 5ODPE OF WORN 0 OELOLS1 AND DISPOSE OF EXISTING COUNTERTOP. 8W(SWASH + SINK. PATCH AND REPAIR AFFECTED AREAS. INCLUDING BUT NOT UNITED TO WALLS, FLOORS AND'CFJUNGS AS REQUIRED MATCHING MING FLASH MATERIALS, UNO. © EXISTING ELECTRICAL PANES SCHEDULED TO REMAIN. O CMG TOILET PARTITIONS AND HARDWARE SCHEDULED TO DE ROIOVED. PATCH AND REPAIR AFFECTED AREAS. INCLUDING BUT NOT LIMITED TO WAIS, FLOORS AND CEILINGS AS REQUIRED MATCHING COSTING FINISH MATERIALS, WOO. © DEMOLISH NT0 DISPOSE OF COSTING WALL MOUNTED SINK. PATCH AND REPAIR AFFECTED AREAS. INCLUDING BUT NOT LIMITED 70 WALES, FLOORS AND CEILINGS AS REQUIRED MATCHING EX571NG FINISH MATERIALS, LINO. O a • lel I0 0 (Ai First Floor Demolition Plan Scala: 1/4'1'-O' GL7OOZb Demolition Notes: U F— U V C.,7 SEATTLE ® METROPOLITAN `ry CREDIT UNION Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. JPC TP MS TP 16-0699 RECEIVED CITY OF TUKWILA PAR 02 2017 PERMIT CENTER EXISTING FIXTURES SCHEDULED TO BE REMOVED AS REQUIRED FOR INSTALLATION OF NEW FLOORING, THEN REINSTAUED. REFER TO NEW FLOOR PUN FOR FURTHER REQUNEHENIS. PROTECT DURING CONSTRUCTION, EXISTING TUBE STEL COLMAN SCHEDULED TO REMAIN. EXISTING BEA0)410 WALL. REMOVE SKIDS BELOW OPENING. HEADER TO RETAIN. EXISTING SHELF SCHEDULED TO BE REMOVED DDIOUSH ELECTRICAL LOM VOLTAGE AND LIFE SAFETY EQUIPMENT/DEVICES (INCLUDING LOW VOLTAGE CABLING) AS REQUIRED DUE TO DWOUTION. AT LOCATIONS WHERE ELECTRICAL S TO BE REMOVED. TERMINATE WIRING AT CLOSEST JUNCTION 80X OR DEMOLISH WIRING BACK 70 PANEL EXISTING H ANDXAI5 SCHEDULED TO REMAIN. EXISTING BFARNS WAIL SCHEDULED TO RETAIN. ALL STUBBED '1P PIPES AND FLOOR WKS TO BE REMOVED IS REQUIRED FOR NEW BUILDOUT. PATCH CONCRETE FLOOR AS REQUIRED. GENNERAI. COMPACTOR TO CONFIRM W (65080 TOILET ACCESSORIES REMAIN. IF SCS. REMOVE COSTING. OBTAIN DEMOLITION P[RMDS AND INCLUDE ALL COSTS OF SOME N CONTRACT PRICE. 2. FURNISH ALL LABOR AND MATERIALS/EQUIPMENT TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED. CONTRACTOR SHALL KEEP CONSTRUCTION AREA FREE OF DUST AND DEBRIS FOR THE DURATION OF CONSTRUCTION. 4. IF ANY WESTIONS ARISE AS TO 7110 REMOVAL OF ANY MATERIAL CLARIFY 111E POINT W OU6110N W1IH THE ARCHITECT BEFORE PROCEEDING. 5. AT COMPLETION OF 00MOUDON WORK, THE C NSTRUCTION AREAS) SHALL 8E LEFT W BROOM came CONDITION. ALL 00885 AND MISCELLANEOUS MATERIAL SHALL BE REMOVED. 6. ALL DEBRIS REMOVAL SHALL RE PERFORMED W ACCORDANCE MATH BUILDING WAGGON R/WWI: S AND PROCEDURES. 7. A5 DIRECTED BY BUILDING MANAGEMENT. ALL DOORS. FRAMES. HARDWARE. MECHANICAL DENS, PLUMBING FIXTURES, LXN7 FIXTURES (INCLUDING DOWN TIGHTS AND FLUORESCENT). AND SPECIAL EQUIPMENT SHOYN TO BE REMOVED, SHALL 8E CLEAN AND FREE OF DEFECTS. PROTECTED, SAVED LAND REUSED AS DIRECTED HEREIN, OR RETURNED 10 BUIDNG STOCK. 8. 9. NO EXISTING SMOKE DETECTOR. PUBUO ADDRESS SPUKER. FIRE MARIA BOX OR SDIIIAR DEVICE. INCLUDING THE ASSOCIATED WIRING MALL BE DAMAGED DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE HARM EQUIPMENT, NECESSITATED BY NEW CONSDBICTWN. SHALL BE ACCOMPLISHED AS A OAST PRIORITY, ANO PER THE PLANS. NO ACTIVE SMOKE D0TEc1OR SHALL BE COVERED OR OTHERWISE REIQVFD OR USED FOR OTHER 11.1AN TS INTENDED PURPOSE RETOVAL OF ANY EOUIPMEM, CASING SNITCHES, AND CONDUIT PERTAINING 70 DATA/COMMUNICATIONS AND TELEPHONE SHALL. BE VERIFIED WITH TELEPHONE COMPANIES AND TENANT. 10. REMOVE AL COSTING MATERIALS WHICH WOULD CAUSE RISES OR DONS W NEW FLOORING SURFACE, SUCH A5 FASTENERS, OUTLET CORES, COVER PUBES, RESILIENT FLOOR COVERINGS, CARPET. CARPET PAD. FLASH PATCH, CONCRETE FIT. PLYWOOD, ETC. 0010111100 15 NOT NECESSARILY UNITED TO WHAT S SHOWN ON DRAWINGS. THE INTENT S TO 6IDIfA1E THE GENERAL SCOPE OF DEMOUTON REWIRED TO COMPLETE THE WORK IN ACCORDANCE WTTI THE CONTRACT DRAWINGS. 11. 12. RATED WAIS SHALL NOT 8E PENETRATED UNLESS THE RATING S MAINTAINED. 13. DISPOSAL ALL DEBRIS REMOVED FRO1 THE STE SHALL BE RECYCLED AS MUCH AS P890110 L AND ALLOWED BY LAW. 12.22.16 PERMIT A 0215.17 C.D.'s RECEIVED MAR 0 3 1017 TUKWILA PUBLIC WORKS JIN6DICIW RMV First Floor Demolition Plan I-1.1 o 2011JPCfr* .n,c 2 8 SCOPE OF WORK *—rT-1—rT1—rT I I 1 1 I I 1 1 1 1 1 I 1 I I 1 I I T ( 11 I, Lgt_ r-1 LJ • REVIEWED FOR CODE COMPLIANCE APPROVED MAR 10 2011 City of Tukwila UILDING DIVISION L. r_ f Mezzanine Demolition Plan \_ Scale. 1/4•=1'-0' CITY PE JPC ARCHITECTS — SEATTLE _ METROPOLITAN CREDIT UNION Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. JPC TP1MS TP 16-0699 ECEIVED OF TUKWILA AR 02 2011 MIT CENTER 12.22.16 PERMIT ® 02.15.17 C.D.'s Key Notes: Demolition Notes: C. NO WORK THIS AREA UNLESS OTHERWISE INDICATED. C. EXISTING WINDOW AND FRAME SCHEDULED TO BE REMOVED. 03 NOT USED. co DEMOLISH ELECTRICAL, LOW VOLTAGE AND UFE SAFETY EQUIPMENT/DEVICES (INCLUDING LOW VOLTAGE CAB0NG) AS REQUIRED DUE TO DEMOLITION. AT LOCATIONS WHERE ELECTRICAL 5 TO BE REMOVED, TERMINATE WIRING AT CLOSEST JUNCTION BOX OR OWLISH WIRING BACK TO PANEL O EXSLING RULING SCHEDULED TO BE REMAIN. EXISTING PANELS AT RAIUNG SYSTEM SCHEDULED TO BE REMOVED. © EXISTING HANDRAILS SCHEDULED TO REMAIN. O EXISTING OPDL'NG IN FLOOR. INFILL FLOOR AS REQUIRED BASED ON PRIOR TENANT'S DEMOUSHED VENT. 0001180 SINK SCHEDULED TO BE MOVED. PATCH AND REPAIR FLOOR AS REQUIRED BASED ON DEMOLITION. Og EXISTING OPENING IN FLOOR. INEILL FLOOR AS REQUIRED BASED ON PRIOR TENANT'S DEMOLISHED DUMBWAITER 1. 2. 3. 4. OBTAIN DEMOLITION PERMITS AND INCLUDE ALL COSTS OF SAME IN CONTRACT PRICE FURNISH ALL LABOR AND MATERIALS/EQUIPMENT TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED. CONTRACTOR SHALL KEEP CONSTRUCTION AREA FREE OF DUST AND DEBRIS FOR THE DURATION OF CONSTRUCTION. IF ANY QUESTIONS ARISE AS TO THE ROAM_ OF ANY MATERW, CLARIFY THE POINT IN 0UE51108 WAIN THE ARCHITECT BEFORE PROCEEDING. 5. AT COMPLETION OF DEMO11110N WORK, THE CONSTRUCTION AREAS) SHALL BE LETT IN 'BROOM CLEAN' CONDITION. ALL DEERS AND MISCELLANEOUS MATERIAL SHALL BE REMOVED. 6. ALL DEBRIS REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING MANAGEMENT REOUIRDAFNS AND PROCEDURES. 7. AS DIRECTED BY BUILDING MANAGEMENT. ALL DOORS, FRAMES, HARDWARE, MECHANICAL ITEMS, PLUMBING FIXTURES, UGFFT FIXTURES (INCLUDING DOWN LIGHTS AND FLUORESCENT), AND SPECIAL EQUIPMENT SHOWN TO 6E REMOVED, SHALL BE CLEAN AND FREE OF DEFECTS, PROTECTED. SAVED AND REUSED AS DIRECTED HEREIN, OR RETURNED TO BUILDING STOCK. 8. NO EXISTING SMOKE DETECTOR, PUBUC ADDRESS SPEAKER. FIRE ALARM BOX OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE DAMAGED WRING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, NECESSITATED BY NEW CONSTRUCTION, SHALL BE ACCOMPUSHED A5 A FIRST PRIORITY, AND PER THE PLANS. NO ACTIVE SMOKE DETECTOR SHALL BE COVERED OR OTHERWISE REMOVED OR USED FOR OTHER THAN IFS IMENDED PURPOSE. 9. REMOVAL OF ANT EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO DATA/COMMUNIFATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANIES AND TENANT. 10. REMOVE ALL EXISTING MATERIALS WHICH WOULD CAUSE RISES OR DEPRESSIONS IN NEW FL00RING SURFACE, SUCH AS FASTENERS, OUTLET CORES, COVER PLATES, RESILIENT FLOOR COVERINGS, CARPET, CARPET PAD, FLASH PATCH, CONCRETE FILL, PLYW00D. ETC. 11. DEMDLJI10N S NOT NECESSARILY UNITED TO WHAT S SHOWN ON DRAWINGS. THE INTENT S TO INDICATE THE GENERAL SCOPE OF DEMOLITION REQUIRED TO COMPIEIE THE WORK IN ACCORDANCE W1114 THE CONTRACT DRAWINGS. 12. RATED WAILS SHALL NOT 8E PENETRATED UNLESS THE RATING 15 MAINTAINED. 13. DISPOSAL ALL DEBRIS RDAOVED FROM TIRE SITE SHALL 8E RECYCLED AS MUCH AS PRACTICAL AND ALLOWED BY LAW. +we50k 811 SU. Mezzanine Demolition Plan 1-1.2 0 p+s..PCArd... PUG SCOPE OF WORK ,003 OO1004 ON 9'-0• • ATM ( 1024 cl p a D Q D D Q D EI COFFEE O ©O r REVIEWED FOR CODE COMPLIANCE APPROVED MAR 102011 PRNATE 1008 o r_ City of Tukwila EUILPING D VISION I'-6 1 CCR. ar 0 MM'S 1010 1011 (11b, First Floor Dimension Plan - scow: 1/4•=7'-0•. U w U o SEATTLE _ METROPOLITAN ,%CREDIT UNION Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. JPC TP 1 MS 1P 160699 RECEIVED CITY OF TUKWILA MAR 02 2017 PERMIT CENTER 1222.16 PERMIT 02.15.17 C.D.'S Partition Legend: Key Notes: Dimension Notes: 4 4 MALE EXISTING SHELL 8 CORE WALLS NEW FULL HEIGHT PAR11110N. REFER TO DETAIL 3/1-9.1. NEW CONIC HEIGHT PM1111011. REFER TO DETAIL 4/1 9.1 NEW FULL HEIGHT PAR111109. REFER TO DEUIL 3/1-9.1. NEW CEILING MGM PARRDON. REFER TO DETAIL 4/1-9.1 Symbols Legend: WALL TAC 0 NO WORK THIS AREA. UNLESS OTHERWISE INDICATED. 2 WHERE DDS1547 GLASS STOREFRONT WINDOWS HAVE BEEN REMOVED, INFILL SY51DJ A5 REQUIRED ID ACCOMMODATE NEW PIAN. SALVAGE 0)051(NG FR0II DELOUOON AS PRACTICAL MATCH [51190. O WHERE PRACTICAL' NEW WALLS HAVE BEEN ALIGNED WRH OR CENTERED ON WINDOW MULLIONS, PILASTERS, EXISTING WALLS. AND/OR SIRUCNRAL COLUMNS. WALLS HAVE BEEN DIMENSONED FOR ADDTHONAL CIARDY WHEN OR WHERE EVER NECESSARY. O ACOUSTICALLY INSINAlE AND SEAL ALL PENEIRAIIONS AND UNIONS BETWEEN DISSIMILAR LUIERDLS (INCLUDING FLOOR/CEILING PLANES. MUD RINGS/JUNCWgN OOKES) RAL. Hawn( FRILL LENGTH 04 paw AS INDICATED. O5 AT EMMONS AS NDCESSRATED BY 114 -WALL' ELECTRICAL M'D/0R MECHANICAL SYSTEMS PRONDE APPRWPoAIE METAL STUD WIDTH TO ACCOMMODATE SIZING REQUIREMENT. CONFORM TO SPECIFIED METAL GAUGE AND SPACING A5 RIMMED BY WALL TYPE REFER TO C0NSTRUCDON LEGEND FOR ADDITIONAL 19F000,1IIN. © VERIFY EXALT FRAMING REQUIREMENTS WITH TENANTS BANK MACHINE VENDOR AT 1111/054 1021 BEFORE [PAWNS TO COMMENCE 0 GENERAL CONMPACTOR TO CGNFIRL EXISTING WALL IS FULL HEIGHT. O INSTALL. 1/2' GIB ON ALL WALLS W11N DAMAGE DUE TO PREVIOUS RMOVAL OF IRE/STONE. 1. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. ALL PARTITION LOCATIONS SHALL BE AS SINN ON PARTITION PLAN. IN CASE OF CONFLICT NOTIFY ARCHITECT. PARI1ION PUN BY ARCHITECT TAKES PRECEDENCE OVER ALL O1HER PIANS. 2. ALL PARMTONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO FINISH FACE OF GYPSUM BOARD UNLESS 011ERWISE NOTED. ALL DIMENSIONS MARKED 'CLEAR' OR 'CR' SHALL BE MAINTAINED AND SHALL *110W FOR IHICKNFSSES OF ALL WALL FINISHES. LINJ.0. 3. DMAN90NS NOTED 'CLEAR' OR 'CUT' MUST 8E ACCURATELY WORMED, AND SHALL NOT VMA MDR IRAN 4 1/8' WITHOUT WREN RISIRUCIION FROM ARCHITECT. 4. DIMEN90115 MARKED 11 MEAN A TOLERANCE NOT GREATER NOR SMALLER THAN 2 INCHES FROM DOWN DIIM N90N. U.N.O. VERIFY HELD DIMEN510NS EXCEEDING TOLERANCE WIN NE ARCHITECT. SECURE ARCHITECTS APPROVAL 5. N0T65 ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFUCTS IN THE LOCANON(S) OF NEW CONSTRUCTDN. UPON COMPLETION OF PAR1I110N LAYOUT, NOTIFY ARCHITECT. VERIFICAl109 OF THE LAYOUT TO BE PROVIDED BY ME ARCHITECT PRIOR TO PARDON INSTALLATION. 6. FIFER TO REFLECTED CDUNG PIANS FOR SOFFITS, CEILING HEIGHTS AND PLENUM BARRIER LOCATIONS. 7. DIMEN90NS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. U.N.O. 8. 'ALIGN' IINNS TO ACCURATELY LOCATE FINISHED FACES IN 111E SAME PLANE 9. ALL DOORS SHALL HAVE 1'-6' CAR. ON MIKE/PULL SIDE AND 1'-0' CAR. ON PUSH SIDE OF DOOR. VERIFY AND ADVISE ARH(IECT OF EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. Juus500, sum, First Floor Dimension Plan -2.1 o v,>sc....b. we 1 11 1 Niv.‘ic SCOPE OF WORK MEAFF ETING 12003 1 --- TION 2000 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 II c-) 500660 12002 e,• 8'-0' 1 1 U • • REVIEWED FOR CODE COMPLIANCE APPROVED MAR 10 2011 1/2' d u City of Tukwila BUILDING DIVISION ` • AFF RR 1 2001 1— Mezzanine Dimension Plan - Scale: 1/4•=1'-0' CIS .43 N W z80 810" C P -t t CV CD o. CD CO 41- SEATTLE METROPOLITAN L. T CREDIT UNION Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 PL DESIGN DRAWN CHECKED NO. JPC TP1 MS TP 16-0699 RECEIVED OF TUKWILA MAR 02 2011 MIT CENTER 12.22.18 PERMIT 02.15.17 C.D.'s Partition Legend: Key Notes: Dimension Notes: EXISTING SHELL & CORE WALLS NEW FULL HEIGHT PARTI0ON. REFER TO DETAIL 3/1-9.1. Symbols Legend: WALL TAG pt NO WORK THIS AREA UNLESS OTHERWISE INDICATED. O INRLL FLOOR AS REQUIRED BASED ON PRIOR TENANT'S DETLOUOON WORK. O WHERE PRACTICAL, NEW WALLS HAVE BEEN ALIGNED WITH OR CENTERED ON WINDOW MOWONS. PILASTERS. EXISTING WALLS, AND/OR STRUCTURAL COLUMNS. WADS HAVE BEEN DIMENSIONED FOR ADDITIONAL CLARITY WHEN OR WHERE EVER NECESSARY. O ACOUSTICALLY INSULATE AND SEAL ALL PENETRATIONS AND UNIONS BETWEEN DISSIMILAR MATERIALS (INCLUDING FL00R/CEIUNG PLANES, MUD RINGS/JUNCTION BOXES) FULL HEIGHT X FULL LENGTH IN EXTENT AS INDICATED. O AT LOCATIONS AS NECESSITATED 8Y 'IN -WALL' ELECTRICAL ANO/OR MECHANICAL SYSTEMS PROVIDE APPROPRIATE METAL SND WIDTH TO ACCOMMODATE SIZING REQUIREMENT. CONFORM TO SPECIFIED METAL GAUGE AND SPACING AS INDICATED BY WALL TYPE REFER TO CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. ® INFILL WALL TO MATCH EXISTNG ADJACENT CONDITIONS. 0 INSTALL NEW TRIM TO MATCH EXISTNG WHERE MISSING OR DAMAGED. 1. DO NOT SCALE DRAWINGS, WRRTEN DIMENSIONS GOVERN. ALL 06900 6 1006110615 SHALL BE AS SHOWN ON PARTITION PIAN. W CASE OF CONFLICT NOTIFY ARCHOECT. PARTITION PLAN BY ARCHITECT TAKES PRECEDENCE OVER ALL OTHER PLANS. 2. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO FINISH FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ALL 011408 I0N5 MARKED 'CLEAR' OR 'CLR' SHALL BE MAINTAINED AND SHAD. ALLOW FOR THICKNESSES OF All WALL FINISHES, U.N.O. 3. DIMENSIONS NOTED 'CLEAR' OR 'CLU' MUST BE ACCURATELY MNNTAINED, AND SHALL NOT VARY MORE THAN t 1/8' WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. 4. DIMENSIONS MARKED 14 MEAN A TOLERANCE NOT GREATER NOR SMALLER THAN 2 INCHES FROM INDICATED DIMENSION, U.N.O. VERIFY FI0D DIMENSIONS EXCEEDING TOLERANCE WTI11 THE ARCHITECT. SECURE ARCHITECT'S APPROVAL NOTIFY ARCHITECT IN MUTING OF ANY DISCREPANCIES OR CONFLICTS IN THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION OF MUTTON LAYOUT. NOTIFY ARCHITECT. VERI0CATION OF THE LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO P646011ON INSTALLATION. 6. REFER TO REFLECTED CEIUNG PLANS FOR WEFTS, CDUNG HEIGHTS AND PLENUM BARRIER LOCATIONS. 5. 7. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. U.N.O. 8. 'AIJGN' MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE 9. ALI. DOORS SHALL HAVE 1'-6' CLR. ON STRIKE/PULL SIDE AND 1'-0' CLU. ON PUSH SIDE OF DOOR. VERIFY AND ANSE ARCHITECT OF EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. Mezzanine Dimension Plan 1-2.2 0 vu. vc weal=m. cuC OBuilt -In Upholstered Bench DOOR HARDWARE EPCO DP419-L-A UPHOLSILMJI 6' BOLSTER SECURE TO BENCH WITH VELCRO 6 UPHOLSTERED HIGH DENSITY FOAM CUSHION BY MILLWORKER SECURE TO PLATFORM WITH VELCRO DOUBLE LAYER OF 3/4" PLYWOOD SUBSTRATE PAM AT ALL EXPOSED EXTERIOR SURFACES TYPICAL PLAN EASE AT TOE KICK U.N.O. PAM AT ALL EXTERIOR SURFACES TYPICAL 4" RUBBER BASE AT TOE KICK OBase Cabinet with Drawer Scale: 1"-1•-0' 24' U.N.O PLAY COUNTER TOP AND BACKSPIASH PROVIDE BLOCKING BEHIND CABINET AND IN WALL AS REQUIRED MELAMINE AT ALL CABINET INTERIORS TYPICAL 3/4" ADJUSTABLE SHELF ON 2" 0.C. SHELF CUPS COUNTER TOP AND BACKSPO SH PER ELEVATIONS PWA APRON CONTINUOUS LEDGER - MATCH TO WALL PROVIDE CONCEALED IN -WALL TUBE STEEL SUPPORT, AS REQUIRED INSULATED EXPOSED DRAIN PIPING OSink Counter- ADA Forward Approach Scats: 1'.1'-0' In O O OCoat Hooks O PLATA PANEL TO BE MOUNTED TO WALL USING CONCEALED HARDWARE, PL -4. 6' O 1 3_ COAT HOOKS: MOCKETT, DP2 SERIES, b" DATER . j" PROJECTION, NOTCHED CYLINDRICAL KNOB, SON NICKEL FINISH OWall Counter PRAM COUNTER TOP AND EDGE SCRIBE TO WALL CONTINUOUS LEDGER TO MATCH WALL DOOR HARDWARE EPCO DP419-L-A 1/8" SCRIBE AT DRAWER UNE PLATA AT ALL EXTERIOR SURFACES TYPICAL l/4" X 4" STEEL SUPPORT EVERY 36" 0.C. 4" RUBBER BASE A7 TOE KICK 10 Pull Out Trash - Section at Island 500le: PLATA AT ALL EXPOSED EXTERIOR SURFACES TYPICAL 5/4" ADJUSTABLE SHELF ON 2 0.C. SHELF CUPS PROVIDE BLOCKING BEHIND CABINET AND IN WALL AS REQUIRED INT.CLR DOOR HARDWARE EPCO DP419-L-A UNDER CABINET UGHT RX1URE-SEE REFLECTED CEILING PLAN FOR LOCATIONS 0 Upper Cabinet with U.C. Lighting Scow: -1 •-1•-0• DOOR HARDWARE EPCO DP419-L-A PLAL1 AT ALL EXTERIOR SURFACES TYPICAL 4' RUBBER I1BASE AT 700 KIC PLATA COUNTER TOP AND BACKSPIASH PROVIDE BLOCKING BEHIND CABINET AND IN WALL AS REQUIRED LOW PROFILE STAINLESS STEEL SINK IN5UATED EXPOSED DRAM PIPING LAELAMINE AT ALL INTERIOR SURFACES TYPICAL . 0 Base Cabinet with Sink - ADA Side Approach Scot: 1'.1'-0' WOR HARDWARE EPC0 DP419-L-A PIAN AT ALL EXTERIOR SURFACES TYPICAL 4" RUBBER 8145E AT TOE KICK 1/4" X 4" STEEL SUPPORT EVERY 36" 0.C. 11 Cabinets - Section at Island 5001.: DOOR HARDWARE EPCO DP419-L-A •i � PAM AT ALL EXTERIOR i SURFACES TYPICAL La ce 4• RUBBER 84SE AT TOE KICK 0 Laptop Charging Cabinet 5001.: 1".1,-0" IN -WALL POWER AND DATA MUST BE ACCESSIBLE FOR USE INSIDE CABINET 11 ADJUSTABLE SHELF ON 2" 0.C. SHELF CUPS RAM BACK PANEL PLAN COUNTER PROVIDE BLOCKING BEHIND CABINET AND IN WALL AS REQUIRED MEWAINE AT ALL CABINET INTERIORS TYPICAL 11 ADJUSTABLE SHELF ON 2" 0.C. SHELF CUPS PROVIDE REINFORCEMENT FOR SAFE SEE PLAN FOR EXACT LOCATION PWA FULL CABINET DOOR W/LOCK-COORDINATE W/ "SHRED -IT 4" RUBBER BASE AT TOE KICK 12 Shred -It Cabinet Scow: 1• . 1'-0' PWI COUNTER TOP AND B4CKSPLASH PROVIDE BLOCKING BEHIND CABINET AND IN WALL A5 REQUIRED MELAMINE AT ALL CABINET INTERIORS TYPICAL JPC ARCHITECTS SEATTLE METROPOLITAN CREDIT UNION Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. JPC TP 1 MS TP 16-0699 RECEIVED CITY OF TUKWILA MAR 02 2017 SHRED -IT BACK TO HANG ON HOOKS ON SDE OF CABINET DETAIL T.B.D. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 10 2017 City of Tukwila BUILDING DIVISION PERMIT CENTER 12.22.16 PERM' ® 02.15.17 C.O.'s SNP Casework Details 1-9.3 0 mn-PC ..w.as.n,C PERMIT COORS COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0026 DATE: 03/02/17 PROJECT NAME: SEATTLE METROPOLITAN CREDIT UNION SITE ADDRESS: 17250 SOUTHCENTER PKWY - SUITE 132 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division IN 3—B-+i� Public Works IMP Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/07/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/04/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) a Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only. CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 CITY PLUMBING INC Hoene l spahol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 A -Z Index Help My I.C1 Workplace Rights Trades & Licensing CITY PLUMBING INC Owner or tradesperson Principals PAPERNIK III, JOSEPH S, PRESIDENT BERKMAN, RICHARD L, VICE PRESIDENT (End: 07/21/2010) Doing business as CITY PLUMBING INC WA UBI No. 602 218 839 11432 47th ave ne MARYSVILLE, WA 98271 360-454-0481 SNOHOMISH County Business type Corporation Governing persons JOE S 111 PAPERNIK RICHARD L BERKMAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no, CITYPI.955KJ Effective — expiration 05/11/2005— 08/01/2018 Bond Lexon Ins Co Bond account no. 9808230 $6,000.00 Received by L&I Effective date 07/07/2011 08/01/2011 Expiration date Until Canceled Bond history Insurance OHIO CAS INS CO $1,000,000.00 Policy no. 54203169 Received by L&I Effective date 06/20/2016 08/01/2010 Expiration date 08/01/2017 Savings No savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602218839&LIC=CITYPI*955KJ&SAW= 3/14/2017 CITY PLUMBING INC Lawsuits against the bond or savings No lawsuits against the bond or savings accc,during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 033,333-00 Account is current. Doing business as CITY PLUMBING INC Estimated workers reported Quarter 4 of Year 2016 "7 to 10 Workers" L&I account representative T3 / KENT ANDERSON (360)902-6963 Email: ANDN235@Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=60221883 9&LIC=CITYPI * 955KJ&SAW= 3/14/2017