Loading...
HomeMy WebLinkAboutPermit PG17-0029 - RENAISSANCE - A/C UNIT GAS PIPINGThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. PG 17-0029 RENAISSANCE 14220 INTERURBAN AVE S #116 RECORDSDIGITAL D-) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Coda Exemption, � � � I3ri6f Explanatory 6escrlofion, Sfatutte/Ruilo The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 12 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. Personal Information — Redactions contain information used to prove RCW DR3 Driver's License. — RCW identity, age, residential address, social security 42.56.230 (7a 42.56.230 number or other personal information required to & c) (7a & c) apply for a driver's license or identicard. Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney -Client Privilege — disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); DR4 RCW 5.60.060(2)(a); RCW which protects attorney-client privileged RCW 42.56.070(1) communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. RENAISSANCE 14220 INTERURBAN AVE S SUITE 116 PG1 7-0029 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov PLUMBING/GAS PIPING PERMIT 3365901881 Permit Number: PG17-0029 14220 INTERURBAN AVE S Unit116 Issue Date: 3/17/2017 Permit Expires On: 9/13/2017 Project Name: RENAISSANCE Owner: Name: Address: Contact Person: Name: BELLTOWN INVESTMENT PARTNER 2505 2ND AVE #520 , SEATTLE, WA, 98121 DANIEL KIM Address: 3132 NE 133 ST, SEATTLE, WA, 98125 Contractor: Name: PSR -HVAC & MECHANICAL SERVICES Address: PO BOX 27073 , SEATTLE, WA, 98165 License No: PSRHVMS9241T Lender: Name: Address: 11/ Phone: (206) 676-9346 Phone: (206) 367-2500 Expiration Date: 4/30/2018 DESCRIPTION OF WORK: INSTALL 100 FEET OF NEW GAS PIPING FOR A NEW ROOFTOP AC UNIT Valuation of Work: $2,808.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $129.28 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2014 2014 2014 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:.r• Print Name: rd �(it irt I e.l k_1 v� Date: 3 / 17/2017 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING CITY OF TUKf 1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. F'01/1- W21 Project No. Date Application Accepted: / 9 h Date Application Expires: o I 1 s (For office use onto) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 3365901881 Site Address: 14220 Interurban Ave S Suite Number: 116 Floor: 1 Tenant Name: Renaissance PROPERTY OWNER Name: Daniel Kim Name: Belltown Investment Partner City: Seattle State: WA Zip: 98125 Address: 2505 2nd Ave #520 Email: daniel.kim@psrmechanical.com City: Seattle State: WA Zip: 98121 CONTACT PERSON — person receiving all project communication Name: Daniel Kim Address: 3132 NE 133rd St City: Seattle State: WA Zip: 98125 Phone: (206) 676-9346 Fax: (206) 368-6856 Email: daniel.kim@psrmechanical.com New Tenant: ❑ Yes ®..No PLUMBING CONTRACTOR INFORMATION Company Name: PSR Mechanical Address: 3132 NE 133rd St City: Seattle State: WA Zip: 98125 Phone: (206) 367-2500 Fax: (206) 368-6856 Contr Reg No.: PSRHVMS924JT Exp Date: 04/30/2018 Tukwila Business License No.: BUS -0993498 Valuation of Project (contractor's bid price): $ 2,808 Scope of Work (please provide detailed information): Install 100 ft of new gas piping for a new rooftop ac unit. Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: H:'ApplicationsWorms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Sewer: Page 1 of 2 Indicate type of plumbing fixtures and/o. as piping outlets being installed and the quantity ,,clow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside.building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow . protections (1-5) I. Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water . treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 I. Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets I. Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY 13Y THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR TI: -LIS PERMIT. BUILDING(OWN Signature: AUT IZED AGENT: Print Name: Dan -1i im Mailing Address: 3132 NE 133rd St H:Wpplications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-1 ].docs Revised: August 2011 bh Date: 03/06/2017 Day Telephone: (206) 676-9346 Seattle WA 98125 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ( ACCOUNT QUANTITY PermitTRAK PAID $129.28 PG17-0029 Address: 14220 INTERURBAN AVE S 150 Apn: 3365901881 $129.28 GAS $124.31 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $66.30 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.86 TECHNOLOGY FEE $4.97 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R11023 $4.97 $129.28 Date Paid: Monday, March 06, 2017 Paid By: PSR MECHANICAL Pay Method: CHECK 013189 Printed: Monday, March 06, 2017 4:11 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I7-Et3ar 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: ReP4-iSs C a Type of Inspection: r/ /, 093' �'/.' Address: / qz� /XrreA vR ,� I Date Cal ed: Special Instructions: Date Wanted: 5 `Z'I 7 ' a.m. ' p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Date: 5: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 %/7-cozq Pr 'ect: ' fit SSA- Type of Inspection: ivr } 'I 6r,& PI PfAi& Address: M /AirniantAy S Date Called: Special Instructions: au rr 116 Date Wanted: 4i /9 m Requester: sn `td' i Phone No: Ze6 Vo g-726 Approved per applicable codes. Corrections required prior to approval. COMMENTS: K-} S` 5"7 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMITCOORDCOPV PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0029 DATE: 03/09/17 PROJECT NAME: RENAISSANCE SITE ADDRESS: 14220 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: k P wt' *0 Building Division Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 03/14/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/11/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: ertnit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 PSR -HVAC & MECHANICAL SEP\'ICES Home lispaiiol Contact Safety & Health Claims & Insurance iIlk Washington State Department of kj Labor & Industries Page 1 of 2 Search L&I A -Z Index Help My I..&1 Workplace Rights Trades & Licensing PSR -HVAC & MECHANICAL SERVICES Owner or tradesperson Principals BAVINS, NEIL JONATHAN, PRESIDENT AUSTIN, MATTHEW W, VICE PRESIDENT STEINKE, CRAIG, CHIEF EXECUTIVE OFFICER O'DONNELL, STEPHEN 0 (End: 04/12/2012) RIST, STEVEN L (End: 04/12/2012) O'MALLEY, JAMES J, MEMBER (End: 04/14/2014) HOGERTY, REAGAN P, MEMBER (End: 04/14/2014) Doing business as PSR -HVAC & MECHANICAL SERVICES WA UBI No. 602 811 195 PO BOX 27073 SEATTLE, WA 98165 206-367-2500 KING County Business type Corporation Governing persons CRAIG STEINKE INC MSHC; MATTHEW AUSTIN; NEIL BAVINS; SRUN KHOU; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PSRHVMS924JT Effective — expiration 04/30/2008— 04/30/2018 Bond International Fidelity Ins Co Bond account no. 0649932 $12,000.00 Received by L&I Effective date 03/28/2014 03/26/2014 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602811195&LIC=PSRHVMS924JT&SAW= 3/16/2017 PSR -HVAC & MECHANICAL SERVICES Insurance Old Republic Ins Co $1,000,000.00 Policy no. A7CG09491601 Received by L&I Effective date 03/24/2016 04/01/2016 Expiration date 04/01/2017 Insurance history Savings (in lieu of bond) $12,000.00 Received by L&I Effective date 04/30/2008 04/30/2008 Release date Impaired date N/A N/A Savings account ID Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No LSI tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 152,899-00 Doing business as PSR MECHANICAL Estimated workers reported Quarter 4 of Year 2016 "31 to 50 Workers" L&I account representative T1 / TYRONE COLEMAN (360)902-4807 - Email: COTI235@Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602811195&LIC=PSRHVMS924JT&SAW= 3/16/2017 SITE INFO ADDRESS: OWNER: PARCEL/TAX # LEGAL: 14220 INTERURBAN AVE S TUKWILA, WA 98168 BELLTOWN INVESTMENT PARTNER 3365901881 HILLMANS SEATTLE GARDEN TRS POR OF LOT 1 & ALL OF LOTS 2 THRU 7 & POR ADJ IN SE 1/4 OF SECTION 14-23-04 DAF — BEG SE COR OF SAID LOT 7 TH NLY ALG ELY LN 315 FT TO LFT BANK OF DUWAMISH RIVER AS ORIGINALLY PLA 1 ILD TH CONTG ON NLY PROD OF SD ELY 220 FT M/L TO LFT BANK AS EXISTED UNDER SUPERIOR COURT CAUSE NO 81-2-05910-4 TH WLY ALG SD BANK TO AN INTSN WITH NELY PROD OF SELY LN OF NWLY 72 FT OF SD LOT 1 TH SWLY ALG SD LN PROD 200 FT M/L TO LFT BANK OF DUWAMISH RIVER AS PLATTED IN ORIGINAL PLAT TH CONTG IN SWLY DIRECTION ALG SELY LN OF NWLY 72 FT OF SD LOT 1 DISTANCE OF 55 FT M/L TO SWLY LN OF SD LOT 1 TH SELY ALG SD LN TO INTSN WITH N MGN OF S 143RD ST FIRST AVE TH ELY ALG SD MGN TO TPOB—TGW POR FOSTER JOSEPH DC #39 BEING POR OF ABANDONED PUGET SOUND ELECTRIC RR R/W IN THE SW 1/4 OF SE 1/4 OF SD SEC 14 SD RR R/W BOUNDED ON NE BY MAULE AVE ON SW BY A LN 20 FT NE OF & PLT NELY MGN OF SR 181 UNDER REC #8905231113 ON THE SE BY R/W #5 & ON THE NW BY R/W #6 BOTH R/W DEFINED IN QCD AUD FILE # 6557639 — TGW VAC MAULE AVE ADJ TGW POR VAC ST ADJ 3365901055 3779200255 Dij //A I IVEI:? 3365901890 3365901510 REVISIONS No changes 5hnll hr) ir,lde to the .cope of work without prior approval of Tukwila Bui#ding Division. NOTE: Revisions wiil requiro a new pia and may include additional plan revi FILE COPY Permit No. + if submittal fees. � Plan review opprov9I is subject to e rors and omissions. Approval of construction clocumentl doos not ai haTt3 the violation of any adopted code +► ordinance. RcA-it of approved Field Copy and co» i} ons i acknow!od od: By: .) Date: S 143RD ST City of T utawi BUILDING DIVISION 000 ()0.0 3365901665 RECEIVED C KWILA Ma 0 b 2017 PERMIT CENTER RE Ltea FOR CODE '"' ILIANCE APPROVED MAR 14 2017 City of Tukwila BUILDING DIVISION 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT z Ps- < Lo J 0 CL W W aC z 0 —J m ce f -- z w 0 >- 5N L.L.. w 1— co w w t— Z 0 N CV 'd r' CO CO 0 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBUSHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. / 1 SEPAcat\TE P . =. J11T R_QUI LE.D FOR: eryicchan cal IT Eicc;rccal ®PIum3bing 0 Gas Piping Ciy of Tul<wilea BUlt.Plti " `Vl:"'!> ..i Lead Tech Engineered By N. SINGER Date N,02/23/2017 `No. Revisionllssue Date /Drawn By D. KIM 02/23/2017 Lead Tech Engineered By N. SINGER Date N,02/23/2017 Project P5176 Street M0.1 i Project Manager N.S. Scale AS NOTED DETAIL 1 ID I \G NTS IN r NEW 1"0 GAS PIPE \' ON ROOF IM NI 1Y4"0 UP TO ROOF —\ EXISTING 2"0 GAS PIPE BELOW ROOFLINE TYP. 2"0 A-8 115 MBH 2"0 —1— SEE DETAIL 1 1"0 47— A-2 150 MBH 1" UP TO ROOF 1" UP TO ROOF ----�� 1"0 A-4 180 MBH 2"0 A-5 120 MBH I 16. 2"0 r 2"0 1"0 2"0 1" UP TO ROOF 1Y"0 2"0 EXISTING 1Y"0 GAS PIPE ON ROOF TYP. 1"0 A-3 120 MBH 1Ya"0� CAPPED -\ 1"0 DOWN TO WATER HEATER 1"0 WATER HEATER 80 MBH A-6 74 MBH %"O /- 1Y"0 1)G l7: 0019 GAS METER 1000 CFM ©15" W.C. DIDI\G GOOF DLA\ - \I -W WO� SCALE: 1 /8"=1'-0" RECEIVED CITY OF TUKWILA LtiktVIEVViiiD FOR CODE COMPLIANCE H M ITAWMJED MAR 14 2011 City of Tukwila BUILDING DIVISION r • 0 CD (7) .P LSI ti t 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT J 0 w Lf) Z Q -�-� W LL 0 0 0 z 0 z 0 ct 1- z W 0 4L. LI_ 0 w 1_— w Q w 1— z 0 N N t -- COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. f Revisionllssue Date/ 1SD KIM /23/2017 D01/ Lead Tech Engineered SINGER \,02/23/2017 Project P5176 Project .Manager N.S AS NOTED M2.3 ] Sheet