Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG17-0054 - MUSEUM OF FLIGHT - BREAKROOM
MUSEUM OF FLIGHT BREAKROOM 9404 E MARGINAL WAY S PGI 7-0054 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 5729800020 Permit Number: PG17-0054 9404 E MARGINAL WAY S Project Name: MUSEUM OF FLIGHT - BREAKROOM Issue Date: 5/22/2017 Permit Expires On: 11/18/2017 Owner: Name: Address: MUSEUM OF FLIGHT FOUNDATION 9404 E MARGINAL WAY S , SEATTLE, WA, 98108 Contact Person: Name: ELIAS GARDNER Address: 110 UNION STREET, STE 300, SEATTLE, WA, 98101 Contractor: Name: AFFIDAVIT - CLARK MILLER Address: License No: Lender: Name: Address: 1!! Phone: (206) 973-1685 Phone: Expiration Date: DESCRIPTION OF WORK: RENOVATION OF EXISTING LIBRARY/STORAGE ROOM INTO BREAKROOM Valuation of Work: $8,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $203.54 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating con 'ruction or the performance of work. I am authorized to sign and obtain this development permit an agre to the conditigns attached to this permit. l Signature:� / Print Name: G %' /AV. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 12: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 13: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 14: ***PUBLIC WORKS PERMIT CONDITIONS*** 15: Prior to issuance provide a completed King County Non -Residential Sewer Use Certificate. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKW1�, Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No. Date Application Accepted: Date Application Expires: (For office ilse on /2- 911 PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SiTE LOCATION Site Address: King Co Assessor's Tax No.: 332404-9019 9404 East Marginal Way South Tenant Name: Museum of Flight --ryl Suite Number: N/A Floor: 2 PROPERTY OWNER Name: Elias Gardner, SRG Partnership Name: Museum of Flight Foundation City: Seattle State: WA Zip: 98101 Address: 9404 East Marginal Way South Email: egardner@srgpartnership.com City: Seattle State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Elias Gardner, SRG Partnership Address: 110 Union Street, Suite 300 City: Seattle State: WA Zip: 98101 Phone: (206) 973-1685 Fax: (206) 973-1701 Email: egardner@srgpartnership.com New Tenant: ❑ Yes ..No PLUMBING CONTRACTOR INFORMATION Company Name: To be determined by Client Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 8,000 Scope of Work (please provide detailed information): Renovation of existing library/storage room into an employee breakroom. Building Use (per Intl Building Code): Museum / Gallery Occupancy (per Int'I Building Code): A-3 Utility Purveyor: Water: H:Wpplications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Sewer: Page 1 of 2 Indicate type of plumbing fixtures and/ot. piping outlets being installed and the quantity oelow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 1 Shower, single head trap Sinks 1 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) 1 Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 2 Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment 1 Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer_. domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping 1 Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official niay grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: OR AU H RIZED A T: Date: 04/19/2017 Print Name: Elias Gardner, SRG Partnership Day Telephone: (206) 973-1685 Mailing Address: 110 Union Street, Suite 300 Seattle WA 98101 City State Zip H:4\pplications\Fomts-Applications On Line\2011 Applications\Plumbing Pemtit Application Revised 8-9-I l.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $2,233.73 D17-0105. Address: 9404 E MARGINAL WAY S Apn: 5729800020 $1,511.59 DEVELOPMENT $1,439.82 PERMIT FEE R000.322.100.00.00 0.00 $1,435.32 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $71.77 TECHNOLOGY FEE I R000.322.900.04.00 I 0.00 $71.77 M17-0054 Address: 9404 E MARGINAL WAY S Apn: 5729800020 $557.74 MECHANICAL $531.18 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $498.03 TECHNOLOGY FEE $26.56 TECHNOLOGY FEE R000.322.900.04.00 0.00 $26.56 PG17-0054 Address: 9404 E MARGINAL WAY S Apn: 5729800020 $164.40 PLUMBING $156.57 PERMIT FEE R000.322.100.00.00 0.00 $123.42 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE - $7.83 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R11536 •:. $7.83 $2,233.73 Date Paid: Monday, May 22, 2017 Paid By: MUSEUM OF FLIGHT FOUNDATION Pay Method: CHECK 91926 Printed: Monday, May 22, 2017 11:52 AM 1 of 1 C. SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS 1 PermitTRAK ACCOUNT QUANTITY PAID $171.94 M17-0054 Address: 9404 E MARGINAL WAY S Apn: 5729800020 $132.80 MECHANICAL $132.80 PLAN CHECK FEE R000.322.102.00.00 0.00 $132.80 PG17-0054 Address: 9404 E MARGINAL WAY S Apn: 5729800020 $39.14 PLUMBING $39.14 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R11326 R000.322.103.00.00 0.00 $39.14 $171.94 Date Paid: Friday, April 21, 2017 Paid By: MUSEUM OF FLIGHT Pay Method: CHECK 91413 Printed: Friday, April 21, 2017 12:08 PM 1 of 1 Ci SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: IWWl 41=76/471-i--PLthv Type of Inspection: 01 116- AA/41N- 41 ZAddress: Address: 9i0 £ nfm6il ift_ bums Date Called: Special Instructions: Date Wanted: /0-3/-17 a:m: pier: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: eq/<- PL,U .Bi Nc- Inspector: Date/ / REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION %)-7- acs4 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:Ty nit)Seiiiivi Oki /Zi614 — a of Inspection: - 1A) l'W; + % 67- Address:j Q 'o`i 1' Agia'lil.�/ . I.+o 7 Date Called: Special Instructions: Date W d: %7 m. Reques r: bin! 50102 2 Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Date: 6'30-- r 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ()ERNT'CQORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0054 DATE: 04/26/17 PROJECT NAME: MUSEUM OF FLIGHT - BREAKROOM SITE ADDRESS: 9404 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: o mv& L Building Division tow two it' Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 04/27/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 05/25/17 ❑ Approved with Conditions Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: tukplan@ci.tukwila.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION 10 11-0 It - PERMIT NO: C1111' o014 `r STATE OF WASHINGTON) ss. COUNTY OF KING ) [please print name] , states as follows: Dh-0105 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number I% , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might othp vis ' ave under state law in any decision to engage an unregistered contractor to perform construction 4. Signed and sworn to before me this 11' day of M A Vael NOTARY PUBLIC in and for the Residing at H Name as commissioned: to of Washington My commission expires: 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28. RCW thatemploys >a certified journeyman electrician, a certified residential s-pecialty electrician, or an electrical trainee meeting the, requirements of chapter 19.28 RCW to perform plumbing work that is incidentally;: directly, and immediately' appropriate to the like -in-kind replacement of a'household appliance or other small household'utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. * Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. D B 3/10/2017 3:47:32 PM ABBREVIATIONS LEGEND DRAWING INDEX SCHEDULES AC ACU AD AFF APPROX ARCH ASHRAE BDD BFF BOD BTUH CD CFM CIRC CO COND CONT COORb COTG CW DEG DIA DIM DN DWG EA ELEV, EL EAT EG ESP EWT EXIST EXH EXP FC FCO FD FDC FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS ID IE IN KW LAT LWG LWT MAX MBH MCA MFG MIN MTG NC NIC NFPA NG NO NTS OA OAT OC OBD ORD OS&Y PH POC PSI RA RL RD REF REQD RG RPM RPBP SA SD SHT SM SO SP SPD SPEC TDH TOD TPD TSP TYP VD VTR WBW WC wco WG WH WHA AIR CONDITIONING AIR CONDITIONING UNIT ACCESS DOOR ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING REFRIGERATION AND AIR CONDITIONING ENGINEERS BACKDRAFT DAMPER BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CLEAN OUT CONDENSATE CONTINUATION COORDINATE CLEAN OUT TO GRADE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING EXHAUST EXPANSION FAHRENHEIT FORWARD CURVED FLOOR CLEANOUT FIRE DAMPER, FLOOR DRAIN FIRE DEPARTMENT CONNECTION FULL LOAD AMPS FEET PER MINUTE FOOT, FEET NATURAL GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALL BOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INDIRECT DRAIN, INSIDE DIAMETER INVERT ELEVATION INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MANUFACTURER MINIMUM MOUNTING NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER OVERFLOW ROOF DRAIN OUTSIDE STEM AND YOLK PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR RAIN LEADER ROOF DRAIN REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE REDUCED PRESSURE BACKFLOW PREVENTER SUPPLY AIR STORM DRAIN SHEET SHEET METAL SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER CLOSET WALL CLEAN OUT WATER GAUGE WALL HYDRANT WATER HAMMER ARRESTER NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW OR X. EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION XxY 7/////////. ////A. EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M100 ABBREVIATIONS, LEGEND, DRAWING INDEX, GENERAL NOTES, 2015 WSEC NOTES, SCHEDULES AND ACCESS PLAN M101 DEMOLITION PLANS M102 FIRE PROTECTION DIAGRAM M103 PLUMBING PLANS M104 MECHANICAL PLANS M105 DETAILS AND SECTIONS GENERAL NOTES SYMBOL $G -X XXX ABBR DN DN + -4- U P I + im""--mmak.r= 1F="324C i• 4. s [s*. -OF �F $ Q OR EQUIP ID# • D 0 D'4 -RS- RL C UP DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD VOLUME DAMPER RA/EA RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SA RA/EA SD SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN`. ,AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE RS RL C TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT REFRIGERANT SUCTION PIPING REFRIGERANT LIQUID PIPING CONDENSATE PIPING ROOM CALL OUT 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE ENGINEER. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC). 5. PENETRATIONS THROUGHOUT 2 -HOUR FIRE RATED WALLS, PARTITIONS, CEILINGS AND ROOF ASSEMBLIES SHALL RECEIVE 2 -HOUR FIRE STOP RATED UL APPROVED SEALANT FROM INSIDE AND WEATHER RESISTANT SEALANT FROM OUTSIDE. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ALL REQUIRED EQUIPMENT GUARDS AND STRUCTURAL SUPPORT AS RECOMMENDED BY EQUIPMENT MANUFACTURERS TO SUPPORT EQUIPMENT AND TO ASSURE SYSTEM PERFORMANCE AND SAFE OPERATION. COORDINATE PRIOR TO INSTALLATION. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. BUILDING AND STRUCTURE IS DESIGNED TO SUPPORT EQUIPMENT, BUT NOT DETAILED TO ACCOMMODATE EACH AVAILABLE EQUIPMENT CONFIGURATION OR MANUFACTURER. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 9. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 10. PROVIDE COMMISSIONING PER WASHINGTON STATE ENERGY CODE. 11' 66 e Ed (f(ok = (3 titPC� 2015 WASHINGTON STATE ENERGY CODE 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE C403.2.3(1)A,(1)B,(1)C,(2),(3),(4),(5),(6),(7),(8),(9),(10) OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 2. PROVIDE DEADBAND BETWEEN HEATING/COOLING SPACE SENSOR SETPOINTS OF 5 DEGREES AS REQUIRED BY SECTION C403.2.4.1.2 OF THE WSEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 3. PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.2.2.1 OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 4. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDRDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED BY SECTION C403.2.8 OF THE WSEC. DUCT TAPE NOT ALLOWED. DUCTWORK STATIC PRESSURE AND SEAL CLASS: WATER COLUMN Y2 TO 2 INCHES ABOVE 2 INCHES SEAL CLASS SEAL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS SEAL TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS 5. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.8 OF THE WSEC AND AS DESCRIBED IN SECTION 230700 OF THE PROJECT MANUAL. DUCT TYPE LOCATION R -VALUE SUPPLY/RETURN EXTERIOR BARRIER R-8, ZONE APPROVED WEATHERPROOF BARRIER) R-12 ZONE 5"( " " ) SUPPLY/RETURN/OUTSIDE AIR OUTSIDE AIR (<2,800 CFM SUPPLY UNIT) UNCONDITIONED SPACE WITHIN CONDITIONED SPACE (NOT CONSIDERED PART OF THE BUILDING ENVELOPE) R-6 R-7 (DAMPER AT ENVELOPE PENETRATION) OUTSIDE AIR(>2,800 CFM SUPPLY UNIT) WITHIN CONDITIONED SPACE (NOT CONSIDERED PART OF THE BUILDING ENVELOPE) MUST INSULATE TO ENVELOPE REQUIREMENTS OF C402 SUPPLY WITHIN CONDITIONED SPACE R-3.3 6. ALL PIPING SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.9 OF THE WSEC AND AS DESCRIBED IN SECTION 220700 AND 230700 OF THE PROJECT MANUAL: MINIMUM PIPE INSULATION THICKNESS SYSTEM/TEMP ('F) INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER CONDUCTIVITY BTU; in./(h • ft2 • F') MEAN RATING TEMPERATURE, 'F < 1" 1" to < 1-1/2" 1-1/2" to < 4" 4" to < 8" >_ 8 HEATING > 350 0.32-0.34 250 4.5 5.0 5.0 5.0 O to O O to 0 LO REF LINES 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 36,6 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 208/1 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 TEMPERATURE 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 COOLING 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 NOTE: A . EXTERNAL STATIC PRESSURE ALLOWS FOR DUCTWORK AND FILTERS, UNIT MANUFACTURER TO ADD ALLOWANCE FOR WET COIL. B . COIL CONDITIONS: COOLING 80/67 'F EAT DB/WB, 95'F OUTDOOR DB; HEATING: 707 EAT DB, 43'F OUTDOOR WB REMARKS: 1. BASIS OF DESIGN: MITSUBISHI MULTI CITY 5. CONSTANT VOLUME FAN COIL 2. NOMINAL COOLING CAPACITIES ARE BASED ON EAT 80/67F (DB/WB), OUTDOOR 95F DB 6. NA 3. NOMINAL HEATING CAPACITIES ARE BASED ON INDOOR COIL EAT OF 70F bB, OUTDOOR 43F WB 7. NA 4. PROVIDE WITH LONG LIFE FILTER, PLENUM WITH FILTER SLIDE, FACTORY INTERNAL DRAIN PUMP & EXTERNAL HEATER ADAPTER; MERV 8. 8. NA < 40 0.20-0.26 75 0.5 1.0 1.0 1.0 7. SIMULTANEOUS HEATING AND COOLING TO INDIVIDUAL ZONES SHALL BE PROHIBITED AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES EXCEPT WHERE PERMITTED IN SECTION C403.2.4.1 OF THE WSEC. 8. VARIABLE FREQUENCY DRIVES SHALL BE PROVIDED FOR VARIABLE FLOW HEATING, AIR HANDLING SYSTEMS, AND WATER SOURCE HEAT PUMP LOOPS SUBJECT TO THE REQUIREMENTS OF SECTION C403.2.13 AND AS DESCRIBED BY SECTION C403.3 OF THE WSEC AND AS DESCRIBED IN THE CONTRACT DOCUMENTS INCLUDING TEMPERATURE CONTROL SEQUENCES. 9. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM AS REQUIRED BY SECTION C403.2.11.3 AND C403.2.14 OF THE WSEC FOR FULL LOAD EFFICIENCIES. 10. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION C408.1.3.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER AS SPECIFIED AND PER SECTION C103.6.2 OF THE WSEC. 11. 12. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2 OF THE WSEC. 13. COMMISSIONING SHALL BE PROVIDED AND REPORT OF COMMISSIONING SHALL BE SUBMITTED TO THE OWNER AS REQUIRED BY SECTION C408 OF THE WSEC. COMMISSIONING SHALL CONSIST OF A COMMISSIONING PLAN, BALANCING, FUNCTIONAL PERFORMANCE TESTING, POST CONSTRUCTION COMMISSIONING, TRAINING, REPORTS AND ACCEPTANCE. SUBMIT COMMISSIONING COMPLIANCE CHECKLIST TO BUILDING OFFICIAL UPON COMPLETION. 14. CONTROL SYSTEM SHALL PROVIDE 7 DAY PROGRAMMING'AND SETBACK CAPABILITY, OPTIMUM START, THERMOSTAT INTERLOCK AND TEMPERATURE RESET. 15. PROVIDE AUTOMATIC SHUTOFF FOR ALL DOMESTIC WATER CIRCULATION PUMPS. SEE ALSO SPECIFICATION SECTION 230900. 16. RESET HEATING AND COOLING TEMPERATURES AUTOMATICALLY PER SECTION C403.4.4.4 OF THE WSEC. SEE ALSO SPECIFICATION SECTION 230900. 17. PROVIDE ISOLATION VALVES FOR ALL EQUIPMENT CONNECTED TO FLUID PIPING. 18. MECHANICAL SYSTEM EQUIPMENT SIZING COMPLIES WITH ENERGY CODE COMPLIANCE LIMITS SECTION C403.2.1 AND C403.2.2. 19. DAMPERS SHALL COMPLY WITH WSEC C403.2.4.3, INCLUDING DAMPERS INTEGRAL TO HVAC EQUIPMENT, AND SHALL HAVE A MAXIMUM LEAKAGE RATE WHEN TESTED IN ACCORDANCE WITH AMCA STANDARD 500 OF: A. B. MOTORIZED DAMPERS: 4 CFM/FT2 OF DAMPER AREA AT 1.0 INCH W.G. NON -MOTORIZED DA PERS: 20 CFM/FT2 OF DAMPER AREA AT 1,0 INCH W.G., EXCEPT THAT FOR NON MOTORIZED DAMPERS SMALLER THAN 24 I CHES IN EITHER DIMENSION: 40 CFM/FT2. 20. THE HVAC SYSTEM AND ITS CONTROLS SHALL ALLOW ECONOMIZER OPERATION WHEN MECHANICAL COOLING IS REQUIRED SIMULTANEOUSLY. AIR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER OF THE COOLING LOAD. 21. ALL DUCT SYSTEMS SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 4 PERCENT OF THE FAN FLOW IF THE DUCT SYSTEM: A. B. C. IS CONNECTED TO A CONSTANT VOLUME, SINGLE ZONE, AIR CONDITIONER, HEAT PUMP OR FURNACE; AND SERVES LESS THAN 5000 SQUARE FEET OF FLOOR AREA; AND HAS MORE THAN 25 PERCENT DUCT SURFACE AREA LOCATED IN ANY UNCONDITIONED SPACE. THE LEAKAGE RATE SHALL BE CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH SMACNA DUCT LEAKAGE TEST PROCEDURES - 1985. No • of work 1 ri,.i t .I o Tukwila r! !�Y Ilt� r+r-1r1 C� I NOTE: Revisions will rcquftd a n.... r, , and may include additional plan VRF INDOOR UNIT SCHEDULE MARK AREA SERVED DESIGN CONDITIONS AIR COOLED OUTDOOR UNIT. 60 MBH NOMINAL COOLING CAPACITY, 95' DB OUTDOOR AIR, 80'/67'F DB/WB INDOOR. 66 MBH NOMINAL HEATING CAPACITY, 43' WB ENTERING AIR, • 70 DEGREE DB INDOOR. 18.6 SEER AND 18.6 HSPF MCA 36A, MOCP 42A. INVERTER DRIVEN SCROLL COMPRESSOR, R410A REFRIGERANT 11.7 EER, 18 IEER, 3.5 COP. 350 POUNDS NET WEIGHT. SOUND PRESSURE 59 DBA MITSUBISHI PIJMY-P6ONKMU1. PROVIDE WITH ALL OPTIONAL PARTS AND ACCESSORIES NECESSARY. BASIS OF DESIGN NOMINAL TOTAL COOLING MBH NOMINAL HEATING CAPACITY MBH CORRECTED SENSIBLE COOLING MBH CORRECTED HEATING CAPACITY MBH NOMINAL TOTAL SUPPLY CFM DESIGN TOTAL SUPPLY CFM MIN. OUTSIDE AIR CFM EXTERNAL STATIC IN. W.G. SOUND PRESSURE DBA MODEL NUMBER VOLTS/ PHASE ELECTRICAL MCA/MOP WEIGHT LBS. REF LINES REMARKS LIQUID IN GAS IN IDU- 1 BREAKROOM 54 60 36,6 47,7 1483 1475 400 0.6 45.0 PEFY-P54NMAU 208/1 3.31A/15A 100.0 3/8" . 5/8" 1,2,3,4,5 AREA SERVED CFM TEMPERATURE CFM IN. W.G. DBA NUMBER PHASE AMPS LBS. HRV-1 BREAKROOM 400 70.5 400 0.54" 33.0 LGH -470 NOTE: A . EXTERNAL STATIC PRESSURE ALLOWS FOR DUCTWORK AND FILTERS, UNIT MANUFACTURER TO ADD ALLOWANCE FOR WET COIL. B . COIL CONDITIONS: COOLING 80/67 'F EAT DB/WB, 95'F OUTDOOR DB; HEATING: 707 EAT DB, 43'F OUTDOOR WB REMARKS: 1. BASIS OF DESIGN: MITSUBISHI MULTI CITY 5. CONSTANT VOLUME FAN COIL 2. NOMINAL COOLING CAPACITIES ARE BASED ON EAT 80/67F (DB/WB), OUTDOOR 95F DB 6. NA 3. NOMINAL HEATING CAPACITIES ARE BASED ON INDOOR COIL EAT OF 70F bB, OUTDOOR 43F WB 7. NA 4. PROVIDE WITH LONG LIFE FILTER, PLENUM WITH FILTER SLIDE, FACTORY INTERNAL DRAIN PUMP & EXTERNAL HEATER ADAPTER; MERV 8. 8. NA VRF OUTDOOR UNIT SCHEDULE MARK REMARKS OUTDOOR UNITS AIR COOLED OUTDOOR UNIT. 60 MBH NOMINAL COOLING CAPACITY, 95' DB OUTDOOR AIR, 80'/67'F DB/WB INDOOR. 66 MBH NOMINAL HEATING CAPACITY, 43' WB ENTERING AIR, • 70 DEGREE DB INDOOR. 18.6 SEER AND 18.6 HSPF MCA 36A, MOCP 42A. INVERTER DRIVEN SCROLL COMPRESSOR, R410A REFRIGERANT 11.7 EER, 18 IEER, 3.5 COP. 350 POUNDS NET WEIGHT. SOUND PRESSURE 59 DBA MITSUBISHI PIJMY-P6ONKMU1. PROVIDE WITH ALL OPTIONAL PARTS AND ACCESSORIES NECESSARY. FILE COPY' Pen f41/1( Plan FT. A ?" pr C i ! subject to errors and o ,._ .. i �...:5�(:`Jt4f� ��`�� 11;72 F. the violation adopted of approved; F: -Ad C By: Data: HEAT RECOVERY VENTILATOR SCHEDULE FIXTURE MARK DESIGN CONDITIONS FIXTURE DESCRIPTION BASIS OF DESIGN VENT CW HW SINK MIN. 2" 2" 1/2" 1/2" SINK: CUSTOM DOUBLE BOWL SINK, 304 STAINLESS STEEL 18 GAUGE SS. OVERALL SINK DIMENSION 43"X22". LEFT BOWL DIMENSION 33"X16"X9". RIGHT BOWL DIMENSION 16"X16"X6.5", ADA RATED. TOP MOUNT. PROVIDE WITH SUPPLIES AND STOPS. PROVIDE SINK DRILLED FOR FAUCET SPECIFIED AND ACCESSORIES. BASIS: ELKAY LRAD. PROVIDE WITH DELUXE DRAIN STAINLESS STEEL BODY FAUCET: SINGLE HOLE TOP MOUNT, PULL DOWN SPRAY, SWING SPOUT, 1.5 GPM AERATOR ADA COMPLIANT, NSF CERFTIFIED LOW LEAD CONTENT. COORDINATE FINISH WITH ARCHITECT. BASIS: ELKAY LKLFHA2031 1 PLUMBING NOTES AND REMARKS: GENERAL: EXTEND AND CONNECT PIPING TO ALL PLUMBING FIXTURES, FURNISH COMPLETE, FUNCTIONAL SYSTEM. 1. PROVIDE WITH GARBAGE DISPOSAL. EFFICIENCY, OUTSIDE EXTERNAL SOUND 0.022 14X12 MINIMUM SURFACE MOUNT PRICE 620D 1,2,316,7,8 TOTAL PERCENT, AIR . STATIC LEVEL MODEL VOLTS/ CIRCUIT WEIGHT MARK AREA SERVED CFM TEMPERATURE CFM IN. W.G. DBA NUMBER PHASE AMPS LBS. HRV-1 BREAKROOM 400 70.5 400 0.54" 33.0 LGH -470 208/1 3.1 200.0 NOTE: A . AIR TO AIR HEAT RECOVERY VENTILATOR, LOSSNAY OR ACCEPTED EQUAL. B . FILTER TYPE: MERV 8 C. INTERLOCK WITH VRF SYSTEM or ordinance. R o 1 ri i.lori3 Scknow!ocs 3d: City of Tukwila BUILDING DIVISION SEPARATE'�Pi:.c.-1A;�^'11iT i Mechanical Vilectncai Q Plumbing LAS Gas Piping City of Tukwila BUILDING DIVISION PLUMBING FIXTURE SCHEDULE FIXTURE MARK SERVICE CONNECTION FIXTURE DESCRIPTION REMARKS WASTE VENT CW HW SINK S-1 2" 2" 1/2" 1/2" SINK: CUSTOM DOUBLE BOWL SINK, 304 STAINLESS STEEL 18 GAUGE SS. OVERALL SINK DIMENSION 43"X22". LEFT BOWL DIMENSION 33"X16"X9". RIGHT BOWL DIMENSION 16"X16"X6.5", ADA RATED. TOP MOUNT. PROVIDE WITH SUPPLIES AND STOPS. PROVIDE SINK DRILLED FOR FAUCET SPECIFIED AND ACCESSORIES. BASIS: ELKAY LRAD. PROVIDE WITH DELUXE DRAIN STAINLESS STEEL BODY FAUCET: SINGLE HOLE TOP MOUNT, PULL DOWN SPRAY, SWING SPOUT, 1.5 GPM AERATOR ADA COMPLIANT, NSF CERFTIFIED LOW LEAD CONTENT. COORDINATE FINISH WITH ARCHITECT. BASIS: ELKAY LKLFHA2031 1 PLUMBING NOTES AND REMARKS: GENERAL: EXTEND AND CONNECT PIPING TO ALL PLUMBING FIXTURES, FURNISH COMPLETE, FUNCTIONAL SYSTEM. 1. PROVIDE WITH GARBAGE DISPOSAL. GRILLES, REGISTERS, AND DIFFUSER SCHEDLUE MARK CFM NC STATIC FRAME/FACE NECK/INLET SIZE MOUNTING BASIS FOR DESIGN COMMENTS LOCATION LEVEL PRESSURE (INCHES) (INCHES) SG -1 375 BREAK ROOM <20 0.022 14X12 12X10 SURFACE MOUNT PRICE 620D 1,2,316,7,8 RG -1 1500 BREAK ROOM <20 0.044 26X16 24x14 SURFACE MOUNT PRICE 630D 1,2,3,6,7,8 RG -2 375 BREAK ROOM <20 0.044 16X14 14X12 SURFACE MOUNT PRICE 630D 1,2,3,6,7,8 NOTES: 1. INSTALL ALL TERMINALS PER MANUFACTURER'S WRITTEN INSTRUUCTIONS. DUCT CONNECTION SHALL BE MINIMUM NECK SIZE. 2. PROVIDE SMOOTH, GRADUAL SHEETMETAL FITTING TRANSITION FROM DUCT TO GRILLE, REGISTER OR DIFFUSER. 3. REFER TO ARCHITECTURAL PLANS (FLOOR, DEILING AND ELEVATIONS) TO VERIFY FRAME TYPE AND LOCATION. 4. FOR LAY -IN STYLE DIFFUSERS, PROVIDE MOUNTING PANEL COMPATIBLE WITH CEILING MODULE WHERE REQUIRED. 5. SDS 2 SLOT DIFFUSER, WITH SDB LINEAR SLOT PLENUM. 6. PROVIDE WITH FIELD FABRICATED PLENUM OF MATCHING SIZE. 7. REFER TO PLAN FOR QUANTITY 8. PROVIDE OPPOSED BLADE DAMPERS AT THE GRILLES MECHANICAL ACCESS PLAN REMOVE GRATES TO ACCESS MECHANICAL EQUIPMENT WELL RECEIVED CITY OF TUKWILA APR 2 1 2017 PERMIT CENTER TRUE NORTH 1 2 3 4 SRG PARTNERSHIP, INC 110 UNION, SUITE 300 SEATTLE, WA 98101 206 973 1700 SRGPARTNERSHIP.COM THE GREENBUSCH GROUP, INC ACOUSTICAL. AUDIO / Vl0W & MECHANICAL ENOMERR10 1900 WEST NCIOOFI STREET SURE 201 SEATflE. WA 96119 (205) 375-0569 (206) 376-0641 FAX 0 0 E 0 0 .e E L j Ca 2 Permit Set Way South Drawing Title ABBRE., LEGEND, DWG. INDEX, GENERAL NOTES, 2015 WSEC, SCHEDULES AND ACCESS PLAN Drawing scales indicated apply to 30" x 42" drawing sheets. Scale may not be accurate if drawing plots are less than this size. Revisions Number Description Date REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 8 2017 • City of Tukwila BUILDING DIVISION Drawn by SN Checked by EL Date 19 March 2017 Project No 216022 Consultant Project No Owner Project No Drawing No 100 B 3/10/2017 3:47:32 PM (E)TERMINAL UNIT AND RETURN GRILLE 16 PHOTO DEMOLITION PLAN LOOKING NORTH SCALE: NONE E Q JANITOR 2.25 r S -J (E) PHOTOCOPY 2.23 L (E)F (E)F (E)F 4, (E) Storage Library 2.24 DEMOLITION FIRE DIAGRAM 2ND FLOOR PLAN J 4 TYP. 12 Bn (E)3/4" NONDIRECT W DN TO SS (E)SHAFT (E)SS (E) JANITOR 2.25 (E)VENT CONTINUE TO OTHER FIXTURES SHEET NOTES: 1. EXISTING CONDITIONS WERE TAKEN FROM RECORD DRAWING AND SELECTIVE FIELD VERIFICATION. ACTUAL CONDITIONS AND DIMENSIONS OF PIPING AND DUCTWORK IN CONCEALED AREAS NEED TO BE FIELD VERIFIED BY CONTRACTOR. 2. COORDINATE SHUTDOWN WITH OWNER. 3. VERIFY FIELD CONDITIONS TO DETERMINE THE EXTENT OF WORK WITH WORK SHOWN ON PLANS. FLAG NOTES: (E) PHOTOCOPY 2.23 L (E)3/4"CWS/R (E)CONDENSATE (E) Storage Library SEE 2.24 MECHANICAL DEMOLITION 2ND FLOOR PLAN SCALE: 1/4" = 1'-0" J J DISCONNECT POWER AND CONTROL. DEMOLISH TERMINAL UNIT WITH 5 KW ELECTRIC COIL AND ASSOCIATED PIPING, SUPPORTS, AND WIRING. SALVAGE CONDENSATE VENT PIPING. ADJUST EXISTING PIPE AS REQUIRED FOR NEW EQUIPMENT. CAP AND DEMO (E)CWS/R ALL THE WAY TO BASEMENT AS REQUIRED TO PROVIDE SPACE FOR NEW PIPING. DEMOLISH (E)CONDENSATE PIPE. REMOVE AND SALVAGE EXISTING SPRINKLER HEAD AND PIPES AS NECESSARY TO PROVIDE COVERAGE TO THE NEW ARRANGEMENT OF SPACE AND COORDINATE WITH NEW MECHANICAL SYSTEMS. REFER TO ARCHITECTURAL REFLECTIVE CEILING PLAN FOR LOCATIONS OF SPRINKLER HEADS. RECEIVED CITY OF TUKWILA APR 2 1 2017 PERMIT CENTER p&il nosy SRG PARTNERSHIP, INC 110 UNION, SUITE 300 SEATTLE, WA 98101 206 973 1700 SRGPARTNERSHIP.COM THE GREENBUSCH GROUP, INC ACOUSOGI.. AUDIO / MED & MECHANICAL INEERING 1800 NEST IRp�N STREET SURE 201 SEATRE. WA 98110 (208) 378-0580 (208) 378-0841 FAX 0 t 4.0 0 w 01) 5 1 3 ©li• Q Is C - co E • Q al) ts; 15 GTLEICa E O • co Permit Set Drawing Title DEMOLITION PLANS Drawing scales indicated apply to 30" x 42" drawing sheets. Scale may not be accurate if drawing plots are Tess than this size. Revisions Number Description Date REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 8 2017 City of Tukwila WING DIVISION Checked by EL Date 19 March 2017 Project No 216022 Consultant Project No Owner Project No Drawing No M10 1 E D C B A 3/10/2017 3:47:32 PM FIRE SPRINKLER NOTES 1. THESE DRAWINGS ARE DIAGRAMMATIC REPRESENTING THE INTENT OF THE WORK. REFER TO THE SPECIFICATIONS FOR COMPLETE SYSTEM REQUIREMENTS. 2. PROVIDE ALL DESIGN, MATERIAL, LABOR, SUPERVISION, TOOLS, AND ITEMS, NECESSARY, FOR THE CONSTRUCTION, INSTALLATION, CONNECTION, START—UP, TESTING AND OPERATION OF ALL FIRE SUPPRESSION WORK FOR THIS PROJECT. IT SHALL BE THE FIRE SPRINKLER CONTRACTOR'S FULL RESPONSIBILITY TO DESIGN AND INSTALL A COMPLETE WORKING SYSTEM MEETING ALL CODES. 3. THE INTENT OF THESE DRAWINGS IS TO DIAGRAMMATICALLY SHOW THE FIRE SPRINKLER PIPING IN CRITICAL AREAS ONLY. THE DRAWINGS DO NOT NECESSARILY REFLECT THE FULL EXTENT OF PIPE R. SYSTEM COMPONENTS REQUIRED OR EXPECTED. THE FIRE SPRINKLER CONTRACTOR IS NOT RELIEVED FROM INCLUDING ALL REQUIRED COMPONENTS AND WORK IN THEIR CONTRACT. 4. PIPE SIZING SHOWN IS AN ESTIMATE, FINAL PIPE SIZE SHALL BE COMPLETED BY THE CONTRACTOR AND INCLUDED IN THE PERMIT SUBMITTAL. CONSTRUCTION SHALL NOT BEGIN UNTIL THE CONTRACTOR'S SHOP DRAWINGS ARE APPROVED BY THE LOCAL JURISDICTION AND SHOP DRAWINGS HAVE BEEN REVIEWED BY THE PROJECT ARCHITECT. 5. FIRE SPRINKLER CONTRACTOR SHALL PROVIDE ADDITIONAL HEADS, PIPING, VALVES AND APPURTENANCES TO ENSURE ADEQUATE COVERAGE IN ALL SPACES. 6. THE AUTOMATIC SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13 (IBC 903.31 STANDARDS), IBC, IFC AND ALL LOCAL CODES AS A MINIMUM STANDARD. ADDITIONAL REQUIREMENTS WILL BE NOTED IN THE SPECIFICATIONS OR IN THESE DRAWINGS THAT EXCEED CODE REQUIREMENTS. 7. FIRE SPRINKLER MAIN NOT SHOWN SHALL BE LAID OUT PER CODE SPECIFIED AND SYSTEM REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR AREAS NOT SHOWN OR FOR MULTIPLE FLOORS THAT REQUIRE FIRE SPRINKLING COVERAGE. 8. ALL PIPING SHALL BE CONCEALED IN FINISHED AREAS TO THE GREATEST EXTENT POSSIBLE. ANY EXPOSED PIPING IN UNFINISHED AREAS SHALL BE ONLY BY APPROVAL OF THE ARCHITECT AND BE PAINTED TO MATCH SURROUNDINGS. IN VAULTED CEILING AREAS, PIPING SHALL BE INSTALLED IN SOFFIT OR BEHIND CEILING FINISH. 9. EXPOSED FIRE SPRINKLING PIPING SHALL BE LIMITED TO THE AREAS SHOWN. ANY DEVIATIONS IN THE FIRE MAIN LAYOUT SHOWN HERE SHALL BE APPROVED BY THE ARCHITECT BEFORE INSTALLATION AND SHALL BE AT NO ADDITIONAL COST TO THE OWNER. NO EXPOSED PIPING WILL BE ALLOWED IF, IN THE BUILDING STRUCTURE, THE ARCHITECT HAS PROVIDED SHAFTS, FURRED AREAS OR CONCEALED SPACES WHERE PIPING COULD BE HIDDEN FROM VIEW. DO NOT RUN PIPING OVER ELECTRICAL PANELS OR SWITCHGEAR EXCEPT WHERE LOCATED ABOVE THE STRUCTURAL CEILING. 10. CENTER SPRINKLER HEADS AND OTHER EXPOSED SPRINKLER SYSTEM ACCESSORIES IN CEILING GRIDS ON CENTERLINES OF ARCHITECTURAL FEATURES. REFER TO ARCHITECTURAL. 11. THE FIRE SPRINKLER CONTRACTOR SHALL COORDINATE THE LOCATION OF THE PIPING AND HEADS TO AVOID INTERFERENCE WITH LIGHT FIXTURES, HEATING/COOLING EQUIPMENT, DUCTWORK AND ANY ARCHITECTURAL FEATURES SUCH AS SKYLIGHTS, STAIRWAYS, ETC. IN CATWALK AREAS, PIPING SHOULD BE RUN AS HIGH AS POSSIBLE TO ALLOW THE MAXIMUM HEADROOM OVER THE MECHANICAL EQUIPMENT AND AISLE SPACES. MAXIMUM CLEARANCE SHALL BE MAINTAINED FOR SERVICE ACCESS AND MAINTENANCE FOR ALL EQUIPMENT. FAILURE TO COORDINATE SHALL BE JUSTIFICATION TO REQUIRE THE CONTRACTOR, AT HIS OWN EXPENSE, TO MOVE AND REDO HIS WORK. 12. 13. PROVIDE THRUST BLOCKS AT ALL CHANGES IN DIRECTION FOR UNDERGROUND SERVICE PIPING. 14. ALL SPRINKLER HEADS SHALL BE QUICK RESPONSE, RECESSED HEADS WHERE EXPOSED IN CEILINGS. ALL PIPING SHALL BE SLOPED PARALLEL TO BUILDING STRUCTURE AND INSTALLED TO DRAIN. LEGEND sYMbol DESCRIPTION UPRIGHT ATTIC SPRINKLER HEAD OSEMI—RECESSED SPRINKLER HEAD DRY SIDEWALL SPRINKLER HEAD FIRE PROTECTION WATER -F FASTENER BRACE +1. FIGURE A WHERE SWAY BRACE FASTENER IS EVEN MTh HANGER POINT OF ATTACHMENT FASTENER BRACE FIGURE B WHERE SWAY BRACE FASTENER IS EVEN WITH HANGER POINT OF ATTACHMENT FASTENER BRACE FIGURE C WHERE SWAY BRACE FASTENER IS EVEN WITH HANGER POINT OF ATTACHMENT MINIMUM 1/2 DEPTH OF BEAM BUT NOT <3 IN. FOR WOOD BEAMS BRACE FASTENER o;• FIGURE D WHERE SWAY BRACE FASTENER IS BELOW HANGER POINT OF ATTACHMENT MINIMUM 1/2 DEPTH OF BEAM BUT NOT G. IN. FOR WOOD BEAMS BRACE FASTENER FIGURE E WHERE SWAY BRACE FASTENER IS BELOW HANGER POINT OF ATTACHMENT MINIMUM 1/2 DEPTH OF BEAM BUT NOT <3 IN. FOR WOOD BEAMS BRACE FASTENER FIGURE F WHERE SWAY BRACE FASTENER IS BELOW HANGER POINT OF ATTACHMENT FASTENER BRACE A4• FIGURE G WHERE SWAY BRACE FASTENER IS BELOW HANGER POINT OF ATTACHMENT FASTENER BRACE FIGURE H WHERE SWAY BRACE FASTENER IS BELOW HANGER POINT OF ATTACHMENT FIGURE I WHERE SWAY BRACE FASTENER IS BELOW HANGER POINT OF ATTACHMENT 1 �` EARTHQUAKE & SWAY BRACE POINT—OF—ATTACHMENT FIGURES M102 / SCALE: NONE (16) ( 1 5 14.5 (13 DETAIL NOTES: 1. CONTRACTOR TO PROVIDE DESIGN, ENGINEERING AND DOCUMENTATION REQUIRED FOR ALL SYSTEM BRACING, HANGERS AND SUPPORTS. SIZE ALL RODS AND BRACE PIPES PER NFPA AND AUTHORITY HAVING JURISDICTIONL RETAINER STRAP STEEL STRUCTURE CONCRETE DECK NUT BEAM CLAMP ALL THREAD ROD HANGER RING TOP BEAM CLAMP DROP—IN ANCHOR ALL THREAD ROD HANGER RING PROP—IN HANGER WALL/COLUMN PERIMETER BEAM EXPANSION BOLT SWAY BRACE END BRACE PIPE 45•-50• FAST CLAMP LATERAL SWAY BRACE CONCRETE CONNECTION WALL/COLUMN PERIMETER BEAMI EXPANSION BOLT SWAY BRACE END BRACE PIPE 2 CONCRETE/STEEL SPRINKLER HANGER DETAIL 4Y-50' SWAY BRACE END PIPE CLAMP LONGITUDINAL SWAY BRACE CONCRETE CONNECTION M102 SCALE: NONE Cki CA-) 0 I I 4OI 9 I L CP H (E)F REF. REF. �-J (E)F ft\ Breakroom 2.24.1 POC, TYP. 3 Lounge 2.24.2 FIRE PROTECTION DIAGRAM SCALE: 1/4" = 1'-0" 3 TYP. 12 4 FLAG NOTES: REINSTALL (E)FIXTURE HEADS. REFER TO ARCHITECTURAL DRAWING, FOR SPRINKLER HEAD LOCATIONS. PROVIDE SUITABLE PIPING CONNECTION TO RELOCATED SPRINKLER HEADS. PROVIDE NEW ESCUTCHEON. RECEIVED CITY OF TUKWILA APR 2 1 2017 PERMIT CENTER P&r7 oc•;q 5 SRG PARTNERSHIP, INC 110 UNION, ,SUITE 300 SEATTLE, WA 98101 206 973 1700 SRGPARTNERSHIP.COM THE GREENBUSCH GROUP, INC " •s ENGINEERING W.1 (208) 378-0559 (206) 378-0641 FAX Permit Set Drawing Title FIRE PROTECTION DIAGRAM N co RI iso E W d Tr 44 O to cm co Drawing scales indicated apply to 30" x 42" drawing sheets. Scale may not be accurate if drawing plots are less than this size. Revisions Number Description Date REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 8 2017 City of Tukwila L RL ILC DIVISION SN Checked by EL Date 19 March 2017 Project No 216022 Consultant Project No Owner Project No Drawing No M102 -J E D B 3/10/2017 3:47:32 PM YZ"V Y2"CW/HW POC POC 32"CW REFRIGERATOR TYP. 2 S-1 POC 2ND FLOOR PLUMBING RESER DIAGRAM NORTH SCALE: NONE (16) PLUMBING LOWER LEVEL PLAN SCALE: 1/4" = C B) POC POC (E)3/4"CW/HW (E)VENT (16) SEE ( 1 5 14.5 (E)VENT CONTINUE T' SHEET NOTES: 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF ANY COMPONENTS. 2. DUCT AND PIPING ROUTING ARE DIAGRAMMATIC IN NATURE. FILED VERIFY ALL CONDITIONS. IT IS THE RESPONSIBILITY OF CONTRACTORS TO COORDINATE VIA SHOP DRAWINGS FOR ANY CONFLICTS WITH OTHER TRADES. 3. EXISTING CONDITIONS WERE TAKEN FROM RECORD DRAWING AND SELECTIVE FIELD VERIFICATION. ACTUAL CONDITIONS AND pIMENSIONS OF PIPING AND DUCTWORK IN CONCEALED AREAS NEED TO BE FIELD VERIFIED BY CONTRACTOR. FLAG NOTES: RUN PIPE INSIDE CASEWORK. COORDINATE WITH ARCHITECT. INSULATE PIPE PER SPECIFICATION. RUN CONDENSATE PIPING IN SOFFIT AND CONNECT TO (E)sa TAILPIECE. PROVIDE SUITABLE FITTING TO EXTEND (E)WASATE PIPE. t�tl—. J_ J---- Y2"cw C 132"V, Y2"CW/HW SEE cra -- I I I 3/4'COND ----�—- J_—_J W#mBreakroo 2.24.1 IDU -1 J Lounge 2.24.2 OPLUMBING 2ND FLOOR PLAN SCALE: 1/4" = 1'-0" RECEIVED CITY OF TUKWILA APR 2 1 2017 PERMIT CENTER SRG PARTNERSHIP, INC 110 UNION, ,SUITE 300 SEATTLE, WA 98101 206 973 1700 SRGPARTNERSHIP.COM THE GREENBUSCH GROUP, INC ACOUSTICAL, AUDIO VTOED & MECwuNCAL ENGINEERING 1900 WEST NK N STREET SURE 201 SE TILE. WA 95110 (208) 378-0584 (208) 378-0841 FAX 0 w 0 E 0 0 L d Permit Set Museum of Flight Drawing Title PLUMBING PLANS Drawing scales indicated apply to 30" x 42" drawing sheets. Scale may not be accurate if drawing plots are Tess than this size. Revisions Number Description Date EVIEWED FOR CODE COMPLIANCE APPROVED APR 2 8 2011 B City of Tukwila ILDING DIVISION Drawn by SN Checked by EL Date 19 March 2017 Project No 216022 Consultant Project No Owner Project No Drawing No M103 _1 (14) E D C B A 3/10/2017 3:47:32 PM MECHANICAL EQUIPMENT WELL ON LOWER LEVEL MECHANICAL ROOM. REFER TO M100 FOR ACCESS. 1 (15) (E)FD RS/L UP TO IDU -1 MECHANICAL LOWER LEVEL PLAN SCALE: 1/4" = 1'-0" 2 (c) B) (A') ( A ) 3 SEE 14.5 J SHEET NOTES: 1. EXISTING CONDITIONS WERE TAKEN FROM RECORD DRAWING AND SELECTIVE FIELD VERIFICATION. ACTUAL CONDITIONS AND DIMENSIONS OF PIPING AND DUCTWORK IN CONCEALED AREAS NEED TO BE FIELD VERIFIED BY 2. CONTRACTOR. DUCT AND PIPING ROUTING ARE DIAGRAMMATIC IN NATURE. FILED VERIFY ALL CONDITIONS. IT IS THE RESPONSIBILITY OF CONTRACTORS TO 3. COORDINATE VIA SHOP DRAWINGS FOR ANY CONFLICTS WITH OTHER TRADES. EXISTING CONDITIONS WERE TAKEN FROM RECORD DRAWING AND SELECTIVE FIELD VERIFICATION. ACTUAL CONDITIONS AND DIMENSIONS OF PIPING AND DUCTWORK IN CONCEALED AREAS NEED TO BE FIELD VERIFIED BY CONTRACTOR. FLAG NOTES: CONNECT IDU -1, ODU-1 AND HRV TO EXISTING DDC BY SIEMENS. INSULATE DUCT LOCATED WITHIN UNCONDITIONED SPACE PER SPECIFICATION. PROVIDE 1" SOUND LINING THE FIRST 10 FT. DUCT RUN. RS/L PIPING TO BE ROUTED IN SOFFIT. CONSULT WITH MANUFACTURER FOR REQUIRED ADDITIONAL REFRIGERANT FIELD CHARGE. PROVIDE PIPING INSULATION FROM INDOOR UNIT TO OUTDOOR UNIT. PROVIDE ACCESS PANEL ON SOFFIT VERTICAL FACE. MINIMUM ACCESS SIZE 20"X20". COORDINATE WITH ARCHITECT. PROVIDE FIRE FIRE CAULK AT PIPE PENETRATION. PROVIDE ACCESS PANEL UNDER IDU -1. 67"X32". PAINT. COORDINATE WITH ARCHITECT. PROVIDE 20"X20" ACCESS PANEL FOR HRV. COORDINATE WITH ARCHITECT. MAINTAIN 10 FEET SEPARATION FROM EXHAUST GRILLE. PROVIDE THERMOSTAT AND COMPATIBLE FACTORY BACNET INTERFACE MODULE TO CONNECT TO (E)BUILDING BAS. I l 9 - -H 1 2.24.11 (375 — 10/10 [ li o/ c Loub l7?421 —7 OSA '- 375 110/ C —7 375 <I <7 10 (i) MECHANICAL 2ND FLOOR PLAN 4 t� 005 5 RECEIVED CITY OF TUKWILA APR 2 1 2017 PERMIT CENTER SRG PARTNERSHIP, INC 110 UNION, SUITE 300 SEATTLE, *A 98101 206 973 1700 SRGPARTNERSHIP.COM THE GREENBUSCH GROUP, INC 1e�0oc ►pct AUcw st r tiAt m 41 (208) 378-0580 (206) 378-0641 FAX Permit Set 0 N C03 3CO 213a W d o • a o� co Drawing Title MECHANICAL PLANS Drawing scales indicated apply to 30" x 42" drawing sheets. Scale may not be accurate if drawing plots are Tess than this size. Revisions Number Description Date REVIEWED FOR ODE COMPLIANCE APPROVED APR 2 8 2017 City of Tukwila BUILDING DIVISION twiny --- SN Checked by EL Date 19 March 2017 Project No 216022 Consultant Project No Owner Project No Drawing No M104 E D C B A 3/10/2017 3:47:32 PM 4 SPRING & NEOPRENE VIBRATION ISOLATOR, TYPICAL, MASON 30 N OR EQUAL THREADED ROD HANGER RL, RS PIPING, SIZE PER MANUFACTURE. INSULATE PER SPECIFICATIONS CONDENSATE PIPING. TRAP AND EXTEND FULL SIZE TO FIXTURE TAILPIECE. INSULATE PER SPECIFICATIONS SUPPLY DUCTWORK TRANSITION FROM UNIT TO DUCT SIZE INDICATED ON PLAN FLEXIBLE CONNECTION TO DUCT, TYPICAL VRF UNIT VRF IDU INSTALLATION DIAGRAM SCALE: NONE CLEANOUT PLUGS & AT EACH CHANGE IN DIRECTION TOWARDS DISCHARGE FULL SIZE VENT FIXTURE TAILPIECE RAIN LINE PIPING SHALL NOT INTERFERE WITH ACCESS TO EQUIPMENT 45 DEC CUT WHEN ROUTED TO FLOOR DRAIN SPILL TO DRAIN OR CONNECT TO FIXTURE TAIL PIECE "A" SHALL BE EQUAL TO THE PLENUM NEGATIVE STATIC "B" SHALL BE EQUAL TO 1/2 THE PLENUM MAXIMUM NEGATIVE STATIC PRESSURE EQUIPMENT COUP�ING OR UNION FOR LONG DRAT LINES. SUSPEND SECURELY FROM STRUCTURE, REFER TO VRF SCHEDULE FOR UNIT WEIGHTS SEISMIC SWAY BRACING AND RESTRAINTS, ALL 4 SIDES PROVIDE ACCESS, TO CONTROL BOX, MOTOR AND FAN PER MANUFACTURER'S WRITTEN INSTRUCTIONS ROUTE DRAIN PIPING TO NEAREST DRAIN FIXTURE TAIL PIECE OR FLOOR DRAIN AS SHOWN ON PLAN. SIZE SHALL BE FULL SIZE OF UNIT'S DRAIN OUTLET OR 114", WHICHEVER IS GREATER. TRAP AT CONDENSATE DRAINAGE PIPING M105 SCALE: NONE 2 AIR OUTLET WITH OPPOSED BLADE DAMPER DUCT LINING DUCT DIMENSION PER PLAN SIDEWALL DIFFUSER DETAIL (TYPICAL) SCALE: NONE 8'-8 3'4' TRUNK DUCT INCREASED AREA & TAKE—OFF (E)WALL MIN. 4" ODU-1 5 AC OUTDOOR UNIT SECTION AIR DISCHARGE FAN, TYP SERVICE PANEL RS & RL, MAKE FLEXIBLE BY SECURING WITH PIPE CLAMP OVER INSULATION PROVIDE 20 GAUGE SHEETMETAL VANDAL RESISTANT COVER FOR ABOVE GROUND RS & RL RS & RL TO IDU -1 8" MINIMUM FLOOR (E)FD M105 SCALE: NONE 3 AIR GAP SINK COUNTER DISHWASHER 7/a" WASTE FLEX HOSE (TYP) � C 12"H W —J 0 n. In 1/2"1 -IW VEN+ TO ROOF 2"W P TRAP 12"CW 6 REFER TO ARCHITECTURAL DOCUMENTS FOR MODEL AND TYPE DISHWASHER CONNECTION DETAIL SCALE: NONE INSULATION. FIT TIGHT TO STRUCTURE PROVIDE 120V POWER. REFER TO ELECTRICAL U.L. RATED FIRE RETARDANT SLEEVE FOR FRAME WALLS; CORE DRILL EXISTING CONCRETE WALL. SLEEVE SIM. TO PRO—SET BRAND THERMOPLASTIC UNITS OR CONTINUOUS 16 GA. GALV. STEEL FLANGED SLEEVES. PIPE. SEE PLANS & ISOMETRIC DIAGRAMS FOR SIZE. PIPE ESCUTCHEON. SIZE TO FIT 0.D. OF INSULATION. SECURE IN PLACE. PROVIDE IN FINISHED SPACES ONLY. TYPICAL PIPE THROUGH WALL DETAIL FIRE RATED ACOUSTICAL FILL ALL AROUND PIPE & FULL DEPTH OF WALL & SLEEVE. SIM. TO DOW CORNING FIRE STOP SEALANT 2000 OR 2003. CUT ROUND OPENING TO SIZE IN EXISTING FRAME WALLS TO FIT PIPE/SEAL/SLEEVE ASSEMBLY. CORE DRILL CONC. WALLS. M105 4 SCALE: NONE 5 RECEIVED CITY OF TUKWILA APR 21 2017 PERMIT CENTER SRG PARTNESHIP, INC 110 UNION, SUITE 300 SEATTLE, WA 98101 206 973 1700 SRGPARTNERSHIP.COM THE GREENBUSCH GROUP, INC 1900 W St I Y9 0 & MEc$ NIGL E , WA 99119 1900 W6T S REE1 SURE 201 SEATRE, WA 98119 (206) 378-0569 (206) 378-0841 FAX 0 w 0 d E 0 0 L Y Permit Set xea Museum of FI Drawing Title DETAILS AND SECTIONS Drawing scales indicated apply to 30" x 42" drawing sheets. Scale may not be accurate if drawing plots are Tess than this size. Revisions Number Description Date REVIEWED FOR CODE COMPLIANCE APPROVED BU APR 2 8 2017 City Of Tukwila !LUNG DIVISION Drawn by SN Checked by EL Date 19 March 2017 Project No 216022 Consultant Project No Owner Project No Drawing No M105