Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG17-0072 - WOODSPRING SUITES - EQUIPMENT
WOODSPRING SUITES 15637 WEST VALLEY HWY PGI 7-0072 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov PLUMBING/GAS PIPING PERMIT 0005800002 Permit Number: PG17-0072 15637 WEST VALLEY HWY Project Name: W00DSPRING SUITES Issue Date: 6/21/2017 Permit Expires On: 12/18/2017 Owner: Name: Address: NELSEN FAMILY TRUST 10510 NORTHUP WY #300 C/O VWC, KIRKLAND, WA, 98033 Contact Person: Name: NICK BLAYDEN Address: Contractor: Name: 10620 NE 9TH PL, BELLEVUE, WA, 98004 WASATCH DC BUILDERS NW LLC Address: 10620 NE 9TH PL, BELLEVUE, WA, 98004 License No: WASATDB846OR Lender: Name: Address: !11 Phone: (425) 999-1523 Phone: (425) 974-7071 Expiration Date: 9/19/2018 DESCRIPTION OF WORK: ALL EQUIPMENT TO BE INSTALLED PER SHEET P-1 [DWV and domestic water supply] Valuation of Work: $798,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $11,327.51 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 L_)__'t Permit Center Authorized Signature: Date: (r)-1-1) I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per agree to the conditions attached to this permit. Signature: Print Na Date: 6-42 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 8004 GROUNDWORK 1900 PLUMBING FINAL 9002 ROUGH -IN GAS PIPING 8005 ROUGH -IN PLUMBING 9001 UNDERGROUND CITY OF TUKW .. 1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. TC0 17— 007,1,. Project No. Date Application Accepted: "t 7 Date Application Expires: \\—)--E-1 7 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 156V W. Valley Hwy., Tukwila, WA 98188 Suite Number: Floor: New Tenant: ® Yes El ..No Tenant Name: WoodSpring Suites Hotel PROPERTY OWNER Name: Lindsey Knox Name: Tukwila Hotel Holdings, LLC. City: Merriam State: KS Zip: 66204 Address: 10620 NE 9th Place Email: lindsey.knox@brrarch.com City: Bellevue State: WA Zip: 98004 CONTACT PERSON — person receiving all project communication Name: Lindsey Knox Address: 6700 Antioch Plaza, Suite 300 City: Merriam State: KS Zip: 66204 Phone: (913) 236-3404 Fax: Email: lindsey.knox@brrarch.com PLUMBING CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 7(1 A , (?OO Scope of Work (please provide detailed information): `-YLul` �ei'c ► 7 -& (Ns1 *1 -mss -Por sly'? d Building Use (per Int'l Building Code). Occupancy (per Int'1 Building Code): Utility Purveyor: Water H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8.9-1 1 .docx Revised: August 2011 bh Sewer Page 1 of 2 Indicate type of plumbing fixtures and/k—oas piping outlets being installed and the quant_, . .elow: Fixture Type_ Qty Bathtub or combination bath/shower 114 Dishwasher, domestic with independent drain :? .. 114 Shower, single head trap 5 Sinks 115 - Rain water system — per drain (inside building) 3 Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 1 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) 5 Fixture Type Qty Bidet 2 Drinking fountain or water cooler (per head) 1 Lavatory 5 Urinal 115— Water heater and/or vent 3 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller 1 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 5 Fixture Type Qty Clothes washer, domestic 8 Food -waste grinder, commercial 8 Wash fountain Water closet 115— Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter 1 Gas piping outlets 5 Fixture Type Qty Dental unit, cuspidor Floor drain 8 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas. Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDINGgOVI�I�jER AUTHORIZED AGENT: �' Signature: ��1// ([� "' Date: n Print Name: Mailing Address: DK011,,,,/p) Qo62o01 P Day Telephone: "12 5", Qq1. /523 • H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $66.83 PG17-0072 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $66.83 PLUMBING $66.83 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R14848 R000.345.830.00.00 1.00 $66.83 $66.83 Date Paid: Monday, July 02, 2018 Paid By: TUKWILA HOTEL HOLDINGS LLC Pay Method: CHECK 1094 Printed: Monday, July 02, 2018 1:20 PM 1 of 1 CRWYSTEMS 0 L 905 Cash Register Receipt City of Tukwila Receipt Number R11731 DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY PAID $16,173.06 EL17-0398 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $7,023.92 ELECTRICAL $6,689.45 PERMIT FEE MULTI-FAM/COMM 1 R000.322.101.00.00 I 0.00 I $6,689.45 TECHNOLOGY FEE $334.47 TECHNOLOGY FEE 1 R000.322.900.04.00 0.00 I $334.47 PG17-0072 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $9,149.14 GAS $99.45 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $66.30 PLUMBING $8,614.02 PERMIT FEE R000.322.100.00.00 0.00 $8,580.87 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $435.67 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11731 R000.322.900.04.00 0.00 $435.67 $16,173.06 Date Paid: Friday, June 16, 2017 Paid By: TUKWILA HOTEL HOLDINGS Pay Method: CHECK 1008 Printed: Friday, June 16, 2017 10:26 AM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT QUANTITY ` PAID $4,546.68 EL17-0398 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $1,672.36 ELECTRICAL $1,672.36. PLAN CHECK FEE R000.345.832.00.00 0.00 I $1,672.36 M17-0073 Address: 15637 WEST VALLEY HWY Apn: 0005800002 $695.95' MECHANICAL $695.95 PLAN CHECK FEE R000.322.102.00.00 0.00 $695.95 i/PG17-0072 Address: 15637 WEST VALLEY HWY Apn:0005800002 $2,178.37 GAS $24.86 PLAN CHECK FEE 1 R000.322.103.00.00 I 0.00 I $24.86 PLUMBING $2,153.51 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R11582 R000.322.103.00.00 0.00 '; $2,153.51 $4,546.68 Date Paid: Friday, May 26, 2017 Paid By: TUKWILA HOTEL HOLDINGS Pay Method: CHECK 1001 Printed: Friday, May 26, 2017 11:30 AM 1 of 1 CArlirWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PG17-007z PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ct: o spr,,.0� Su,s Type of Inspection: Pl..., red() 16-- �� L Ad Address: 15637 cJ sf- V V t Date Called: Special Instructions: Date Wanted: S-5 -206 a.m. p.m. Requester: Phone No: Approved per:applicable codes. Corrections required prior to approval. COMMENTS: Pip, g- Bfl tt- 1•11� Inspector: Date: 5-11? REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P617-007 Z Pro ct: nn Lt O c� w S St 4 T e of Inspection: r1-L^rnb / ►� F,jt%a Address: ,} /501 I IP y Date Called: a v_� -2,0e Special Instructions: O Date Wanted: 9-2:7 - Za/S a.m. P.m. Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: I. S- -L- AJg4 4.0 1.141 -UG ,Zooms Inspector: cfL. Date: y_ �7 _ z. REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P6 i7-oo7Z PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ct: . Oc�Strr c rs Type Tye of Inspection: /14 t `, ran R Address: /5(o37 LtJJ Vaal Date Calle —� Special Instructions: Date Wanted: Ca.m 2 7-LON:" P•m• Requester v ICI O 1 CC) Phone No: r— 24t -372-8b5-8 Approved per applicable codes. Corrections required prior to approval. COMMENTS: tft: stic vnurofP14.Awilp�n�- Lem-- --- fit• ea/ 3/10 7 47k (0/22/ 17 -SOL. Inspector: Date: 9 7- 2og REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD IM Retain a copywith permit INSP ION NO. PGI -1-0072 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PKV: `��..� G.i�rti'� I.t, — lli611111114 /ri � TA_ Typeof ection:� oT 'it'db, 4507 t0k11 14,i/ J tij C9/7S P t f r ►' CAL Special Instructions: /i cJ Date Wanted: Zi` /Z- 2©lic a.m. p.m. Requester: Acb r Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: ---____ — lli611111114 /ri � TA_ r/./i, ,V471/ g (c4ks. 0- E c&1 --e cvv a lr� miss 1 Ats 1--Ott/JILT !fr I) r —o brfrs', 2i 0 1 44% 3. sA(P wWJ S-110,15 �. (WO/ T, i.,n/S7 p de Acb r Cf A))J Gbr pvv.31 At.n.ifryr Jn.-e , Inspector. C c_GL-.--- Date:q,,2--2' S REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PC -17-0072. Project: A/WU SPR) NGS 61h7E5 Type of Inspection: ipe Rov t4-- Ai GA -S pipe- Address:Date Address:. /5c 37 � �� Y 41-1-6Y )/ Called: Special Instructions: Date Wanted: _ I -Z qa p.m. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: mak- / WUG/f /N 615% 4/Noc Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd:, Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431=3670 Permit Inspection Request Line (206) 438-9350 Project: k 2DsPR/NC--. s 3`U/TAS Type of Inspection: R.0116.2-# ,'H PLUM t,3i1 G. Address:Date /5137 . +,oe r 461-1.24 gig Called: Special Instructions: 0 /1©U6�-Jf PG.tJ010111 G A7` wiNG- Date Wanted: 1 a,m. . /f -.2-V--/ ' 7 p.m. RAri iUj�Y Phone No: 5- 44,g— ' goo OApproved per applicable codes. 1_J Corrections required prior to approval. COMMENTS: r./et C3 jrz<:) t)6 //Y p 04413%1l -- (NG - Inspector: 1-"S<- Date: :/zr'� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P&7-ck 72d PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ® ai P X$ S�I7S Type of Inspection: Address: /57.37 Ak rV ll / Date Called: Special Instructions: / 0 ..//)r /®L 01w /AK Date Wanted: //-,2/-1 7 a m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: n '(4/)(- L1 V,i L Inspector: Date: �� S REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1m7-OV7Z Project: 6Vba111der ire Tx of Inspection: v:„.4.4 ' /%.r FLon'gi406, Address: /5-637 1d itAW / thAil Date Called: Special Instructions: • Date Wanted: ' 7�gi7 a.m. Requester: Phone No: giApproved per applicable codes. EJCorrections required prior to approval. COMMENTS: RioAK Inspector: A2‘ Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be. paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: // /./_ j Ty e ofd Inspection: Address: ®� /56%7 ,1./r V io y �' /, thd/ Date Called: Special Instructions: - Date Wante : 6 22/ 7 a:m' Requeste Phone No: Approved per applicable codes. Q Corrections required prior to approval. COMMENTS: Inspector: (0' Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. brr Change Narrative Project Name: WoodSpring Suites Project Description: New Construction Project Number: 31000057 ARCHITECTURAL SHEET LS1.1 — BUILDING CODE AND LIFE SAFETY PLANS DETAIL 1— FIRST FLOOR LIFE SAFETY PLAN 1. Revised wall of Elevator Machine Room. 2. Addition of 2 -hour rated wall. SHEET A1.1 -.FIRST FLOOR PLAN DETAIL 1— FIRST FLOOR PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. SHEET A1.6 — FIRST FLOOR RCP DETAIL 1- FIRST FLOOR RCP 1. Revised wall of Elevator Machine Room. SHEET A4.1 — ENLARGED PUBLIC PLANS DETAIL 1— FIRST FLOOR ENTRANCE PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. DETAIL 2 - FIRST FLOOR FURNITIRE PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. SHEET A4.2 — ENLARGED FINISH PLANS DETAIL 1— FIRST FLOOR REFLECTED CEILING PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. DETAIL 2 — FIRST FLOOR FINISH PLAN Project Location: Delta Number: Revision Date: Page 1 of 3 FILE Tukwila, WA 9 — CCD#5 09/08/2017 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 8 2011 City of Tukwita BUILDING DIVISION 2. Revised room name to Elevator Machine Room. 4'01. Revised wall of Elevator Machine Room. www.brrarch.com 1 REVISION NO RECEIVED CITY OF TUKWILA SEP 162017 RMIT CENTER. 6700 Antioch Plaza. Suite 300, Merriam, KS 66204 MAIN 913.262.9095 Kansas City - Bentonville - Phoenix - San Francisco - Philadelphia - Atlanta - Austin - Miami - Los Angeles - Chicago Page 2 of 3 SHEET A6.2 — ELEVATOR PLANS, SECTIONS & DETAILS DETAIL 1— TYPICAL ELEVATOR TOWER SECTION 1. Revised room name to Elevator Machine Room. DETAIL 3 — FIRST FLOOR ELEVATOR PLAN 1. Addition of finish dimensions. 2. Revised room name to Elevator Machine Room. DETAIL 5 — UPPER FLOOR ELEVATOR PLAN 1. Removed elevator control panel note. SHEET A7.1— PARTITIONS, FINSH SCHEDULE & DETAILS ROOM FINISH SCHEDULE 1. Revised room name to Elevator Machine Room. SHEET A8.1— DOOR SCHEDULE & DOOR DETAILS DOOR SCHEDULE 1. Revised room name to Elevator Machine Room. 2. Revised fire rating of Elevator Machine Room. MECHANICAL SHEET M-1— MECHANICAL NOTES, SCHEDULES, AND LEGENDS SCHEDULE — DUCTLESS SPLIT SYTSEM SCHEDULE 1. Added to plans SCHEDULE — EXHAUST FAN FAN SCHEDULE 1. Remove EF -5. SHEET M-2 — MECHANICAL FIRST FLOOR PLANS DETAIL 4 — MECHANICAL FIRST FLOOR PLAN 1. Update elevator machine room. 2. Add FCU -1 to elevator machine room. SHEET M-5 — MECHANICAL FOURTH FLOOR PLANS DETAIL 3 — MECHANICAL ROOF PLAN 1. Add CU -1. DETAIL 4 — ELEVATOR SHAFT RELIEF HOOD DETAIL 1. Revise control description. PLUMBING SHEET P-2— PLUMBING WASTE AND VENT PLAN 1ST FLOOR DETAIL 1— FIRST FLOOR WASTE & VENT 1. Revised sump pump drain line and floor drain per elevator change. SHEET P-6 — PLUMBING WATER AND GAS PLAN 1ST FLOOR DETAIL 1— FIRST FLOOR WATER AND GAS PLAN 1. Added hose bib per owner directed RFI. SHEET P-10 — PLUMBING ENLARGED PLANS www.brrarch.com 6700 Antioch Plaza, Suite 300, Merriam, KS 66204 MAIN 913.262.9095 Kansas City - Bentonville - Phoenix - San Francisco - Philadelphia - Atlanta - Austin - Miami - Los Angeles - Chicago Page 3 of 3 DETAIL 1—SUMP PUMP DETAIL 1. Revised sump pump drain line and floor drain per elevator change. ELECTRICAL SHEET E-1— ELECTRICAL RISER DIAGRAM PANELBOARD SCHEDULES 1. Revised per drawing updates. SHEET E-2 — ELECTRICAL PLANS — FIRST FLOOR PANELBOARD SCHEDULES 1. Revised per drawing updates. SHEET E-3 — ELECTRICAL PLANS — FIRST FLOOR DETAIL 1— FIRST FLOOR ELECTRICAL PLAN 1. Added callout for elevator control room. DETAIL 3 — ENLARGED LAUNDRY 1. Revised treadmill electrical circuit. DETAIL 4 — ENLARGED ELEVATOR 1. Added detail and keynotes. SHEET E-6 — ELECTRICAL PLANS — FOURTH FLOOR DETAIL 2 — ELEVATOR ELECTRICAL PLAN 1. Removed detail. DETAIL 3 — ELECTRICAL ROOF PLAN 1. Added CU -1. End of Revision/Addendum/Construction Change Directive By: BRR Architecture, Inc., Drew Truskey, Designer www.brrarch.com 6700 Antioch Plaza. Suite 300, Merriam, KS 66204 MAIN 913.262.9095 Kansas City - Bentonville - Phoenix - San Francisco - Philadelphia - Atlanta - Austin - Miami - Los Angeles - Chicago For Health Hazard Applications Job Name loo 1,4 , f — 11.1KK.)1u4 Job Location Engineer Approval Contractor Approval Contractor's P.O. No Representative ES-LF909L ED JUN 16 2017 LEAD FREE* Series LF909 Reduced Pressure Zone Assemblies Sizes: 21/2" -10" (65-250mm) Series LF909 Reduced Pressure Zone Assemblies are designed to provide cross -connection control protection of the potable water supply in accordance with national plumbing codes. This series can be utilized in a variety of installations, including health hazard cross - connections in plumbing systems or for containment at the service line entrance. With its exclusive relief valve design incorporating the "air-in/water-out" principle, it provides substantially improved relief valve discharge performance during the emergency conditions of combined backsiphonage and backpressure with both checks fouled. The LF909 features Lead Free* construction to comply with Lead Free* installation requirements. Features RECEIVED • Replaceable seats CITY OF TUKWILA • Stainless steel internal parts • No special tools required for servicing JUN 16 2017 • Captured spring check assemblies • Fused epoxy coated & lined checks— PERMIT CENTER • Industrial strength sensing hose • Feld reversible relief valve • Air-in/water-out relief valve design provides maximum capacity during emergency conditions Available Models suffix: LF — NRS — 0SY - 0T -FDA — without shutoff valves non -rising stem resilient seated gate valves UL/FM outside stem & yoke resilient seated gate valves FDA epoxy coated quarter -turn ball v TUKwitA PUBLIC WORKS CORRECTION LTR# S -FDA — FDA epoxy coated strainer Note: The installation of a drain line is recommended. line, an air gap is necessary. Now Availabl WattsBox Insulated Enc For more information, send for liter NOTICE Inquire with goveming authorities for local inst First Check Assembly Relief Valve Second Check Assembly Pipe Line Cente Relief Valve Body Flange Ives Specifications REVIEWED i'ctiI eTP'itis%gtitaiMPLIaI APPROVE[etween JUN 2 pBacks t° the 201 Water lures. closing ture ES -WB. Lead Fr City of Tukwils aa co BUILD ► _ �IVI *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Relief Valve Seat Relief Valve Piston Relief Valve Piston Assembly Wiper Seal Bottom Plug Spring Assembly • Pressure Zone Assembly shall be installed at each cross - to prevent backsiphonage and backpressure backflow of materials into the potable water supply. The assembly ist of a pressure differential relief valve located in a zone o positive seating check valves and captured springs. nage protection shall include provision to admit air directly duced pressure zone via a separate channel from the charge channel. The assembly shall include two tightly utoff valves before and after the valve and test cocks. The * Reduced Pressure Zone Assembly shall comply with res and standards, where applicable, requiring reduced ent. The assembly shall meet the requirements of td. 1013; AWWA Std. C511-92; CSA B64.5; and UL File No. 17(3185. Listed by IAPMO (UPC). Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southem California. The assembly shall be a Watts Series LF909. Pc,ri 00 72 Watts product spans Technical m U.S. customary usand mnigh are approh ngeior te many are provided si for referencenstronly. For cations measurements, with- ON please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incuning any obligation to make such changes and modifications on Watts products previously or subsequently sold. Materials Check Valve Bodies: FDA epoxy coated cast iron Seats: Stainless steel Trim: Stainless steel Relief Valve Body: 21/2"-3" (60-80mm) Lead Free* cast copper silicon alloy 4"-10" (100-250mm) FDA epoxy coated cast iron Test Cocks: Lead Free* copper silicon alloy Pressure — Temperature Temperature Range: 33°F -110°F (0.5°C -43°C) continuous, 140°F (60°C) intermittent Maximum Working Pressure: 175psi (12.06 bar) Standards AW WA C511-92 IAPMO PS 31, SBCCI (Standard Plumbing Code) USC manual for Cross -Connection Control, 8th Edition *The wetted surface of this product contacted by consumable water contains Tess than 0.25% of lead by weight. Capacity *Typical maximum flow rate (7.5 feet/sec.) kPa psi 138 20 103 15 69 10 35 5 21/2" (65mm) AP 0 25 50 75 0 95 190 285 5 1.5 kPa psi 138 20 103 15 69 10 35 5 AP kPa psi -138 20 103 15 69 10 35 5 100 125 380 475 7.5 2.3 150 175 200 225 250 275 300 gpm 670 665 760 855 950 10451140 pm 15 fps 4.6 mps 4" (100mm) 0 0 100 380 200 760 5 1.5 300 1140 7.5 2.3 8" (200mm) 400 1520 10 3.0 500 1900 15 4.6 600 gpm 2280 Ipm fps mps AP 0 200 400 600 800 1000 0 760 1520 2280 3040 3800 5 1.5 1200 1400 1600 1800 2000 gpm 4560 5320 6080 6840 7600 Ipm 7.5 10 fps 2.3 3.0 mps How It Operates The unique relief valve construction incorporates two channels: one for air, one for water. When the relief valve opens, as in the accompanying air-in/water-out diagram, the right- hand channel admits air to the top of the reduced pressure zone, reliev- ing the zone vacuum. The channel on the left then drains the zone to atmosphere. Therefore, if both check valves foul, and simultaneous nega- tive supply and positive backpres- sure develops, the relief valve uses the air -in/ water -out principle to stop potential backflow. Approvals SP® us 1013 B64.4 Water Air Out In Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southem Califomia. kPa psi 138 20 103 15 69 10 35 5 AP kPa psi 138 20 103 15 69 10 35 5 3" (80mm) 50 190 100 150 200 380 570 760 5 7.5 1.5 2.3 6" (150mm) 250 300 950 1140 350 1330 15 4.6 400 gpm 1520 Ipm fps mps AP 0 200 400 600 800 0 760 1520 2280 3040 5 7.5 1.5 2.3 kPa psi 138 20 103 15 69 10 35 5 10" (250mm) 1000 1200 3800 4560 1400 1600 gpm 5320 6080 Ipm 15 fps 4.6 mps AP 0 0 500 1900 5 1.5 1000 1500 3800 5700 2000 7600 7.5 2.3 2500 9500 10 3.0 3000 gpm 11400 Ipm fps mps Dimensions — Weights NOTE: Valve may be fumished with (2) OSY or (2) NRS Shutoffs. NOTE: Relief valve section is reversible, therefore, can be on either side and is fumished standardly as shown. ro o 010 OUTLET Quarter -tum (QT) Valve Watts G-4000 Series Ball Valves Send for F -G4000 SIZE (DN) in. mm in. A mm Al in. mm C clearance for (OSY)* in. mm check (NRS) in. mm in. DIMENSIONS D mm in. L mm U in. mm R in. mm R (OT) in. mm in. T mm NRS lbs. kgs. WEIGHT OSY lbs. kgs. OT lbs. kgs. 211 65 4114 1048 205/8 524 163% 416 9% 238 51/4 133 26'% 663 11 279 4 102 16 406 9'/ts 230 195 88.4 198 89.8 182 82.6 I 3 80 421/4 1073 211 540 18% 479 101/4 260 51/4 133 26'% 663 11 279 5 127 16 406 9'/6 230 225 102 230 104 1 190 86I 4 100 55'% 1400 275/4 702 223/4 578 123/2 310 6 152 37 940 14 356 6 152 193/4 502 14% 365 455 206 470 213 352 160 6 150 65% 1664 323/4 832 30'% 765 16 406 6 152 44%2 1130 16 406 11 279 26 660 143/8 365 718 326 798 362 762 346 8 200 781/2 2000 39% 1000 373/4 959 191516 506 93/4 248 551/4 1403 21 533 111/4 286 111/4 286 193/4 489 1350 612 1456 660 2286 1037 10 250 93% 2378 46% 1190 453/4 1162 2313/6 605 93/ 248 67% 1711 21 533 121/2 318 121/2 318 21 533 2160 980 2230 1011 3716 1685 'UL, FM approved backflow preventers must include UUFM approved OSY gate valves. NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before begin- ning the installation of this product. Air Gap Dimensions When installing a drain line on Series 909 backflow preventers that are installed horizontally, use 909 AG series air gaps. For flange size backflow preventers installed vertically (flow down), a fabricated air gap is recommended. Strainer Dimensions SIZE (DN) in. mm IRON BODY MODEL NO. ORDERING CODE SERIES/SIZES In. N mm DIMENSIONS 21/2 65 WEIGHT 254 10 254 in. A mm in. B mm in. C mm lbs kgs 1 909AG-F 881378 1V4" -x' 009/909 4% 111 63/4 171 2 51 3.25 1.47 81/4 210 60 11/4"-2"009 M1 2" 009 M2 6 150 181/2 470 20 508 131/2 343 133 909AG-K 881385 4" - 6" 909 8" -10" 909 M1 6% 162 9% 244 3 76 6.25 2.83 10 909AG-M 881387 8" -10" 909 7% 187 113/4 286 4 102 15.5 7.03 For flange size backflow preventers installed vertically (flow down), a fabricated air gap is recommended. Strainer Dimensions SIZE (DN) in. mm in. M mm DIMENSIONS N1 1- In. mm In. N mm WEIGHT lbs. kgs. 21/2 65 10 254 10 254 61/2 165 28 12.7 3 80 103/4 257 10 254 7 178 34 15.4 4 100 123/4 308 12 305 81/4 210 60 27 6 150 181/2 470 20 508 131/2 343 133 60 8 200 215/2 549 223/4 578 151/2 394 247 112 10 250 26 660 28 711 1811 470 370 168 t - Dimension required for screen removal For additional information, visit our web site at: Watts.com \SWAm® A Watts Water Technologies Company ES-LF909L 1611 USA: Tel: (978) 689-6066 • Fax: (978) 975-8350 • Watts.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • Watts.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • Watts.com © 2016 Watts brr Change Narrative Project Name: WoodSpring Suites Project Description: New Construction Project Number: 31000057 ARCHITECTURAL SHEET LS1.1— BUILDING CODE AND LIFE SAFETY PLANS. DETAIL 1— FIRST FLOOR LIFE SAFETY PLAN 1. Revised wall of Elevator Machine Room. 2. Addition of 2 -hour rated wall. SHEET A1.1— FIRST FLOOR PLAN DETAIL 1- FIRST FLOOR PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator. Machine. Room. SHEET A1.6 — FIRST FLOOR RCP DETAIL 1— FIRST FLOOR RCP 1. Revised wall of Elevator Machine Room. SHEET A4.1 — ENLARGED PUBLIC PLANS DETAIL 1— FIRST FLOOR ENTRANCE PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. DETAIL 2 — FIRST FLOOR FURNITIRE PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. SHEET A4.2 — ENLARGED FINISH PLANS DETAIL 1— FIRST FLOOR REFLECTED CEILING PLAN 1. Revised wall of Elevator Machine Room. 2. Revised room name to Elevator Machine Room. DETAIL 2 — FIRST FLOOR FINISH PLAN 1. Revised wall of Elevator Machine'Room. 2. Revised room name to Elevator Machine Room. Project Location: Delta Number: Revision Date: Tukwila, WA 9 — CCD#5 09/08/2017 1 REVISION NO, RECEIVED CITY OF TUKWILA SEP 1 8 2017 MIT CENTER Page 1of3 www.brrarch,com 6700 Antioch Plaza.:Suite 300, Merriam. KS 66204 MAIN 913,262.9095 Kansas City - Bentonville - Phoenix - San Francisco - Philadelphia - Atlanta - Austin - Miami - Los Angeles - Chicago Page 2 of 3 SHEET A6.2 — ELEVATOR PLANS, SECTIONS & DETAILS DETAIL 1— TYPICAL ELEVATOR TOWER SECTION 1. Revised room name to Elevator Machine Room. DETAIL 3 — FIRST FLOOR ELEVATOR PLAN 1. Addition of finish dimensions. 2. Revised room name to Elevator Machine Room. DETAIL 5 — UPPER FLOOR ELEVATOR PLAN 1. Removed elevator control panel note. SHEET A7.1— PARTITIONS, FINSH SCHEDULE & DETAILS ROOM FINISH SCHEDULE 1. Revised room name to Elevator Machine Room. SHEET A8.1— DOOR SCHEDULE & DOOR DETAILS DOOR SCHEDULE 1. Revised room name to Elevator Machine Room. 2. Revised fire rating of Elevator Machine Room. MECHANICAL SHEET M-1— MECHANICAL NOTES, SCHEDULES, AND LEGENDS SCHEDULE — DUCTLESS SPLIT SYTSEM SCHEDULE 1. Added to plans SCHEDULE — EXHAUST FAN FAN SCHEDULE 1. Remove EF -5. SHEET M-2 — MECHANICAL FIRST FLOOR PLANS DETAIL 4— MECHANICAL FIRST FLOOR PLAN 1. Update elevator machine room. 2. Add FCU -1 to elevator machine room. SHEET M-5 — MECHANICAL FOURTH FLOOR PLANS DETAIL 3 — MECHANICAL ROOF PLAN 1. Add CU -1. DETAIL 4 — ELEVATOR SHAFT RELIEF HOOD DETAIL 1. Revise control description. PLUMBING SHEET P-2 — PLUMBING WASTE AND VENT PLAN 1ST FLOOR DETAIL 1— FIRST FLOOR WASTE & VENT 1. Revised sump pump drain line and floor drain per elevator change. SHEET P-6 — PLUMBING WATER AND GAS PLAN 1ST FLOOR DETAIL 1— FIRST FLOOR WATER AND GAS PLAN 1. Added hose bib per owner directed RFI. SHEET P-10 — PLUMBING ENLARGED PLANS www.brrarch,com 6700 Antioch Plaza, Suite 300, Merriam, KS 66204 MAIN 913.262.9095 Kansas City - Bentonville - Phoenix - San Francisco - Philadelphia - Atlanta - Austin - Miami - Los Angeles - Chicago Page 3 of 3 DETAIL 1—SUMP PUMP DETAIL 1. Revised sump pump drain line and floor drain per elevator change. ELECTRICAL SHEET E-1— ELECTRICAL RISER DIAGRAM PANELBOARD SCHEDULES 1. Revised per drawing updates. SHEET E-2 — ELECTRICAL PLANS — FIRST FLOOR PANELBOARD SCHEDULES 1. Revised per drawing updates. SHEET E-3 — ELECTRICAL PLANS — FIRST FLOOR DETAIL 1— FIRST FLOOR ELECTRICAL PLAN 1. Added callout for elevator control room. DETAIL 3 — ENLARGED LAUNDRY 1. Revised treadmill electrical circuit. DETAIL 4 — ENLARGED ELEVATOR 1. Added detail and keynotes. SHEET E-6 — ELECTRICAL PLANS — FOURTH FLOOR DETAIL 2 — ELEVATOR ELECTRICAL PLAN 1. Removed detail. DETAIL 3 — ELECTRICAL ROOF PLAN 1. Added CU -1. End of Revision/Addendum/Construction Change Directive By: BRR Architecture, Inc., Drew Truskey, Designer www.brrarch.com 6700 Antioch Plaza, Suite 300. Merriam. KS 66204 MAIN 913.262.9095 Kansas City 4 Bentonville - Phoenix - San Francisco - Philadelphia - Atlanta - Austin - Miami - Los.Angeles - Chicago B R R architecture Code Comment Response 06/14/2017 City of Tukwila Department of Community Development 6300 Southcenter Boulevard Suite #100 Tukwila, Washington 98188 RE: WoodSpring Suites — 15637 West Valley Highway, Tukwila, WA 98188 Dave McPherson, We have revised our plans to address your resubmittal comments relative to our WoodSpring Suites project located at 15637 West Valley Highway. We have provided the following package consisting of revised drawings and narrative responses with attachments to all comments gathered from your report. Your comments are in regular type followed by our responses in bold face type. Jon Olson, Project Manager (BRR Architecture): (913) 236-3491 jon,olson©brrarch.com PLUMBING 1. Specify size, make and model number of the domestic backflow device on plumbing plan sheet P-9. Submit backflow device (RPPA) cut sheets and circle the backflow to be installed. Verify that the domestic backflow (RPPA) is an approved Washington State Department of Health device. RESPONSE: Make and model number of backflow (RPPA) added to detail 3 on P-9. See attached spec sheet for backflow selection. Backflow is approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California. Again, thank you for your timely review. I hope you find this response package to satisfactorily answer all of your code comments. If there is anything further you need from us, please call me directly at the number below. Sincere) l,// on • son Direct Phone: 913-236-3491 Fax: 913-262-6913 RECEIVED CITY OF TUKWILA CORRE ION JUN 16 2017 LTR# PERMIT CENTER P&ri 007z June 08, 2017 City of Tukwila Department of Community Development LINDSEY KNOX 6700 ANTIOCH PLAZA - SUITE 300 MERRIAM, KS 66204 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG17-0072 WOODSPRING SUITES - 15637 WEST VALLEY HWY' Dear LINDSEY KNOX, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: PW - PG DEPARTMENT: Dave McPherson at 206-431-2448 if you have questions regarding these comments. • 1. Specify size, make and model number of the domestic backflow device on plumbing plan sheet P-9. Submit backflow device (RPPA) cut sheets and circle the backflow to be installed. Verify that the domestic backflow (RPPA) is an approved Washington State Department of Health device. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely, )1/1 achelle ' ipley Permit Technician File No. PG17-0072 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 ."Ei�/1+� vyr/1 OM; V Vii l PLAN REVIEW/ROUTING SLIP PERMIT NUMBER:: PG17-0072 DATE: 09/21/17 PROJECT NAME: WOODSPRING SUITES SITE ADDRESS: 15643 W VALLEY HWY Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: A- 011 Building Division br\ I\VA— Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 09/21/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/19/17 Approved Corrections Required (corrections entered in Reviews) (ie: Zoning Issues) Approved with Conditions ❑ Denied �� Notation Y'o� I WII 7� �/l 17(ityl,c l� 1 V ,(/)%i 11I `/+• w�Il PW =ov rerrencti.l ��" a\� 1 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 wERMiT COORD COPY.. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0072 DATE: 06/16/17 PROJECT NAME: WOODSPRING SUITES SITE ADDRESS: 15637 WEST VALLEY HWY Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division ❑ c tri - Fire Prevention Structural Planning Division I I ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/20/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/18/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD. COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0072 DATE: 05/25/17 PROJECT NAME: WOODSRING SUITES SITE ADDRESS: 15637 WEST VALLEY HWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: kS RTWG Building Division pal C V Public Works 41\0 Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/30/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: WW1 DUE DATE: 06/27/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg li«jl Fire ❑ Ping 0 PW' Staff Initials: 12/18/2013 PROJECT NAME: Vv t i S I 1 WI PERMIT NO: 1� ' &J12 SITE ADDRESS: OgQD F W VA1ley ORIGINAL ISSUEDATE: (D 0 9-)4 l 11 REVISION LOG REVISION NO.I, DATE RECEIVED STAFF IALS ISSUED DATE 10(13 STAFF INITIALS_ S fl - /I Summary of Revision: ;LJ' Al.I �_ J Received by: McAti REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.aov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 09.18.17 Plan Check/Permit Number: P 11' 0 O T2-- ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # X❑ Revision # 0 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: WoodSpring Suites Project Address: 15643 W Valley Hwy Contact Person: Lindsey Knox Phone Number: 913.236.3404 Summary of Revision: The overall change was switching elevator types. The owner switched from a electric traction elevator to a machine room hydraulic elevator. It included adding a machine room adjacent to the elevator. Sheet Number(s): 18 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on W.\Permit Center\Templates\Forms\Revision Submittal Form. doc Revised: August 2015 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: n=2-14-11 Plan Check/Permit Number: P6 - 0012- O Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: 1,-100c,sp — ttet — ^C-t`.tr-4.114.,ar 14 Pc Project Address: 1S-( 1 Wer -sr \/Ai -LEY 4-b4T Tiaktu(Lioc , 1l6 ' Contact Person: 1......04175.6r kro X Phone Number: (U ) Summary of Revision: "(44 (f-N-EC.11c i tef'1 1ie. L_ c uES'wExp "Rhe Srt.� Merwiocet_ NUwitgaa dF -The t:,0, AEs1\L- -ME . r'wtvti ,t, , R_ranq ct T- LFI). TthS l,�t o,crv►�FClcy. t•-1✓tS Mavctaet" -ry tpern-IL ono P--9 ANC) Al - so P (De -V c,. 1_ - t'- 7r PvwPosGrrg,NeAeIF:LouI - RECEIVED CITY OF TUKWILA JUN 16.2017 PERMIT CENTER Sheet Number(s): ri Shei_ot..t SPEC StkkeT. "Cloud" or highlight all areas of revision includin - date ! f revision �fr6 Received at the City of Tukwila Permit Center by: 0 Entered in TRAKiT on W:\Permit Center\Templates\Forms\Revision Submittal Form.doc Revised: August 2015 Non -Residential Sewer Jse Certification Sewage Treatment Capacity Charge -'G I`]_ 0072 To be completed for all new sewer connections, reconnections or change of use of existing connections. Please Print or Type IWOw.UALt Property Street Address 1i.ik-.14/ !A_ t/4. City State ZIP IVkwlik lot M AR/5 Owner's Name ro6ZO A/6 Pktce Owner's Mailing Address State ZIP City `/23' . Q? 4j, 707 Owner's Phone Number including Area Code • 1175 -'°jq j. /6S.; Property Contact Phone Number including Area Code Party to be Billed (if different from owner) Address City State ZIP A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 1 (A-6 Shower, per head 2 2 1a,.( Nil 225 Dishwasher 2 2 'l 2 '1.4:5 Drinking fountain (each head) 1 .5 1 , 5' Hose bibb (interior) 2.5 2.5 12, 5 Clothes washer or laundry tub 4 2 f 4r Sink, bar or lavatory 2 1 115- L t 5" Sink, Clinic flushing 8 8 Sink, kitchen 3 2 1 15 230 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Water closet, tank or valve, 1.6 GPF 6 3 1 3 Water closet, tank or valve, >1.6 GPF 8 4 Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total Fixture Units _ 20 RCE King County Department of Natural Resources and Parks Wastewater Treatment Division For King County Use Only Account # No. of RCEs Monthly Rate Property Tax ID # (561)6{' ooec., Subdivision Name Subdiv. # Building Name (if applicable) City or Sewer District Date of Connection Side Sewer Permit # Lot # Block # Please report any demolitions of pre-existing structures on this property. Credit for a demolition may be given under some circumstances. (See King County Code 28.84.050, 0.5) Demolition of pre-existing structure? ❑ Yes ❑ No Was structure on Sanitary Sewer? ❑ Yes [1] No Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date Type of structure demolished Request to apply demolition credit to multiple structures? ❑ Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility/Process: RECEIVED CITY OF TUKWILA Estimated Wastewater Discharge: Gallons/days MAY 252017 Residential Customer Equivalent CENTER 187 gallons per day equals 1.0 R Total Discharge (gal/day) _ 187 RCE C. Total Residential Customer Equivalents: (add A & B) A 63,43- +B 0 63,615 - Total RCE Pursuant to King County Code 28.84.050, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the Metropolitan King County Council at a rate per month, per residential customer or residential customer equivalent, for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206-477-5516. I understand that the information given is correct. I understand that the capacity charge levied will be based on this information. 1 understand that any devia on ; ay result in a revised capacity charge. Signature of Owner/Representative Print Name of Owner/Representative leen caan,,, nnn.or rn,.,er rnn rhn lnca in.l,i 1Nhita — Kinn r:ni mnh, Vnllnu, — 1 oral Ro,mor Anonnv Date Pink — Rowor R, IctnmAr IRev. 1 ntt R1 1202M i WASATCH DC BUILDERS NW L111 Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & industries Search L&I Page 1 of 2 A -Z Index Help My L&1 Workplace Rights Trades & Licensing WASATCH DC BUILDERS NW LLC Owner or tradesperson Principals Nielson, Michael James, MANAGER West77 Partners LLC, MANAGER Doing business as WASATCH DC.BUILDERS NW LLC WA UBI No. 603 591 156 10620 NE 9th PI BELLEVUE, WA 98004 425-974.7071 KING County Business type Limited Liability Company Governing persons LLC WEST77 PARTNERS MICHAEL NIELSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. WASATDB846OR Effective — expiration 09/19/2016— 09/19/2018 Bond Western Surety Co Bond account no. 62697583 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 09/19/2016 09/15/2016 Expiration date Until Canceled Insurance Ironshore Specialty Ins Co $1,000,000.00 Policy no. AGS0100700 Received by L&I Effective date 10/13/2016 10/12/2016 Expiration date 10/12/2017 Insurance history Savings No savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603591156&LIC=WASATDB846OR&SAW= 6/21/2017 WASATCH DC BUILDERS NW I. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 523,517.01 Doing business as WEST77 CONSTRUCTION LLC Estimated workers reported Quarter 1 of Year 2017 "4 to 6 Workers" L&I account contact Employer Services Help Line — 360-902-4817 Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603591156&LIC=WASATDB8460R&SAW= 6/21/2017 NMI 9/7/2017 4:37:11 PM 8" SANITARY SEWER INVERT 4'- 8" BELOW F.F. COORDINATE DEPTH WITH CIVIL 3"RD REFER TO CIVIL PLANS FOR CONTINUATION 3"RD REFER TO CIVIL PLANS FOR CONTINUATION Li RESTROOM STAIRS LEVATOR MACHINE GUEST LAUNDRY ACC QUEEN FAMILY SUITE FITNESS EWC _o i- (TYP) 11 1" P-2 HALL/ VENDIN P-3 ;4 H \ ,,/z/>) / \ / DOUBLE \,' / � /% QUEEN \ \ �// \ i/ / SUITE \ . \I117 , \,\} j // / P-2 \ ✓ ,�' DOUBLE \ QUEEN 4" CLEANOUT 3"FD WCO (TYP) LOBBY QUEEN - SUITE 'REGISTRATION LFCO STAFF LAUNDRY P-1 \P-2 1132 1 P-1 P-2 DOUBLE; QUEEN !. SUITE SEPARATE PERMIT REQUIRED FOR: I 'vtechanical CAlectrical 0 Plumbing I4as Piping City of Tukwila BUILDlNQ DIVISION REVISIONS No changes shall b� to the scope of work without prior approval of Tukwila Buifding Division. NOTE: R visiions will require a new plan submittal and may include additional plan review fees. COPY Permit NaPG 11- 00`1 2 - Plan Plan review approval is Approval of construction the viol i' at any adopt of approved Field Copy By: Date: VESTIBULE TRAINING 8 3"RD CONNECTED TO ROOF DRAIN REFER TO ARCHITECTURAL PLAN FOR DETAILS 3"RD REFER TO CIVIL PLANS FOR CONTINUATION PLUMBING KEYNOTES (0 ,® ) 1. SEE RISER DETAIL 1 ON SHEET P8. 2. PROVIDE JR SMITH MODEL 2420 FLOOR DRAIN WITH SEDIMENT BUCKET. SEE ARCHITECTURAL PLANS FOR TRENCH DETAIL. 3. REOUTE SUMP PUMP PIPING UNDERSLAB TO FLOOR DRAIN. INDIRECT OVER DRAIN WITH HALF GRATE. PROVIDE AIR GAP. 4. PROVIDE INDIRECT DRAIN CONDENSATE FROM FCU TO FLOOR DRAIN WITH 2" AIR GAP. PROVIDE FLOOR DRAIN WITH HALF GRATE. 5. PROVIDE INDIRECT DRAIN FOR VENDING MACHINES TO FLOOR SINK WITH 2" AIR GAP. PROVIDE FLOOR DRAIN WITH HALF GRATE. 6. EXTEND 1/2" CW FROM TRAP PRIMER. CONNECT CW FOR PRIMER SYSTEM TO NEAREST 1" CW PIPE OR LARGER. 7. SEE RISER DETAIL 2 ON SHEET P8. 8. SEE RISER DETAIL 3 ON SHEET P8. 9. SEE RISER DETAIL 4 ON SHEET P8. 10. SEE RISER DETAIL 5 ON SHEET P8. 11. SEE RISER DETAIL 6 ON SHEET P8. 12. SEE RISER DETAIL 7 ON SHEET P8. 13. SEE RISER DETAIL 8 ON SHEET P8. 14. PROVIDE 4"W TO LINT TRAP AND CONNECT TO BUILDING SEWER. 4" INLET/OUTLETS PROVIDE RISERS AS REQUIRED. 15. SEE RISER DETAIL 9 ON SHEET P8. 16. SEE RISER DETAIL 10 ON SHEET P8. 17. CONNECT DISHWASHER DRAIN LINE TO P-5 P -TRAP WITH DISHWASHER CONNECTION. TYPICAL FOR ALL STUDIOS. \ FIRST FLOOR WASTE & VENT SCALE: 1/8" = 1'-0" DRAINAGE FIXTURE UNIT FIXTURE QUANTITY WASTE TOTAL WATER CLOSET 1 4 4 LAVATORY 1 1 1 BATHROOM GROUP 114 5 570 SINK 114 2 228 LAUNDRY SINK 1 2 2 4" FLOOR DRAIN 3 6 18 3" FLOOR DRAIN 3 5 15 2" FLOOR DRAIN 2 2 4 PUBLIC WASHING MACHINE 6 3 18 EXTRACTORS 2 6 12 TRENCH DRAIN 1 6 6 TOTAL 878 3"RD CONNECTED TO ROOF DRAIN REFER TO ARCHITECTURAL PLAN FOR DETAILS 3"RD REFER TO CIVIL PLANS FOR CONTINUATION P-1\ -2 DOUBLE %,/ \QUEEN� SUITE " ,�/K , /�: . •lam \ / QUE SUITEEN City of T BUILDING DI ,/P-5 PROVIDE CLEANOUTS AT THE BASE OF ALL WASTE RISERS N STAIRS / INVERT 1.33' BELOW F.F. 4" CLEANOUT FL4II' 0012- REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 8 2017 tp City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 18 2017 PERMIT CENTER REVISION NO.! B R R Architect of Record: BRR Architecture, Inc. Kansas City 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P 913 322 5150 ® P9133225155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with its Issue date and It is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 6 05/31/17 CCD #2 9 09/08/17 CCD #5 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF/AR Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title PLUMBING WASTE AND VENT PLAN - 1ST FLOOR Sheet No. P-2 BRR Original printed on recycled paper 9/7/2017 4:37:20 PM 9.4 18"AFG RESTROOM STAIRS 3/4" CW DOUBLE QUEEN SUITE ACC QUEEN FAMILY SUITE DOUBLE QUEEN! SUITE FITNESS HALL/ VENDING 1" CW 1" HW \ /\ „9%\> -\ \ /�✓ DOUBLE \✓,-' QUEEN. SUITE/ 3" CW 2 1/2" HW 1 1/2" HW 3/4" HWC STAFF LAUNDR 1-1/2"HWR FROM THIRD FLOOR �P-5 STAFF LAUNDRY SEE SITE PLAN FOR CONTINUATION OF DOMESTIC AND FIRE PROTECTION WATER LOBBY 3/4" CW REGISTRATION Ienl ADJOINING ROOM P-11 18" AFG 3/4" CW 3/4" HW i P-10 DELUXE CORNER SUITE 1/2" CW 3/4" CW TRAINING \ P-5 > P-2 VESTIBULE NOTES: 1. PROVIDE STAND PIPE FIRE PROTECTION SYSTEM IN STAIRWELL PER CITY REQUIREMENTS. 2. PROVIDE DRY PIPE FIRE PROTECTION SYSTEM IN ATTIC. \QUEEN/ SUITE FIRST FLOOR DOMESTIC WATER PLAN SIGNATURE SCALE: 1/8" = 1'-0" WATER FIXTURE UNIT FIXTURE QUANTITY WATER TOTAL WATER CLOSET 1 2.2 2.2 LAVATORY 1 0.7 0.7 BATHROOM GROUP 114 3.6 410.4 SINK 114 1.4 159.6 LAUNDRY SINK 1 1.4 1.4 WASHERS 6 3 18 COMMERCIAL WASHER 2 4 8 ICE MACHINE 1 6 6 HOSE BIBB 2 2.5/1 3.5 MOP SINK FAUCET 1 3 3 TOTAL 612.8 RUN 1/2" CROSS-LINKED POLYETHYLENE FROM MANIFOLD TO EACH PLUMBING FIXTURE ON BOTH FIRST AND SECOND FLOORS. PEX MANIFOLDS SHALL BE ZURN, PROVIDE PEX COMPATIBLE COPPER MANIFOLDS AND WALL STUBS. PEX SUPPLY LINES SHALL BE HOMERUNS FROM THE MANIFOLD LOCATED ABOVE THE CORRIDOR CEILING TO THE OUTLET. MANIFOLDS IN CORRIDORS TO BE ACCESSIBLE. 1 PLUMBING KEY NOTES (1 00 ) 1.. 2 1/2" COLD AND HOT WWATER UP TO 3RD FLOOR CEILING. 2. 2 1/2" COLD AND HOT WATER UP FROM 1ST FLOOR CEILING. 3. PROVIDE COPPER MANIFOLD FOR WATER DISTRIBUTION. PROVIDE ISOLATION VALVES UP STREAM OF MANIFOLD FOR COMPLETE SYSTEM ISOLATION. (TYPICAL) MANIFOLDS TO BE INSTALLED IN CORRIDOR. 4. REFER TO ARCHITECTS DETAIL FOR MOUNTING HEIGHTS OF TUB/SHOWER FAUCET AND CONTROLS. (TYPICAL) 5. ROUTE 1/2" TO UNIVERSAL FLUSH MANIFOLD (BY OWNER). COORDINATE WITH OWNER FOR EXACT MOUNTING HEIGHTS AND INSTALLATION DETAILS. 6. DROP 1-1/2" COLD AND HOT WATER DOWN IN WALL TO WASHERS. HOLD TIGHT TO CORNER @ STAFF LAUNDRY. EXTEND 3/4" SUPPLY LINES TO MOP FAUCET. 7. EXTEND 3/4" CW TO DRYER FOR FIRE SUPPRESSION SYSTEM INSIDE DRYER. PROVIDE VALVE AND SPIGOT. SPIGOT TO BE INSTALLED ON CEILING. INSTALL LINE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. 8. PROVIDE RAYCHEM SELF REGULATING PROTECTION SYSTEM ON HOSE AT CONNECTION FROM HOSE BIBB TO COMMERCIAL DRYER. SIZE AND INSTALL PER MANUFACTURER'S INSTRUCTIONS WITH 3/4" INSULATION SURROUNDING PIPE AND HEAT TRACE. CONNECT TO ADJACENT ELECTRICAL OUTLET BY E.C. 9. MOUNT HOSE BIBB AT 40" A.F.F. SEE ARCHITECTURAL PLANS. 10. DROP 3/4" HW/CW DOWN IN WALL TO WASHER BOX. 11. PROVIDE CPVC EXPANSION JOINT PER MANUFACTURER'S INSTRUCTIONS. SIMILAR TO FLEXICRAFT MODEL CP. INSTALL AS REQUIRED THROUGHOUT WATER SYSTEM. 12. SEE RISER DETAIL 1 ON SHEET P-9. 13. SEE RISER DETAIL 2 ON SHEET P-9. 14. SEE RISER DETAIL 3 ON SHEET P-9. 15. SEE RISER DETAIL 4 ON SHEET P-9. 16. SEE RISER DETAIL 5 ON SHEET P-9. 17. ROUTE GAS TO DRYERS PER MANUFACTURERS INSTRUCTIONS. 18. CONNECT DISHWASHER SUPPLY TO HOT WATER SUPPLY OF P-5. TYPICAL FOR ALL STUDIOS. 19. DO NOT ROUTE WATER IN EXTERIOR WALLS. WATER CLOSET SUPPLY TO BE THROUGH FLOOR. 20. TAP 1/2" COLD WATER OFF P -5H WATER SUPPLY FOR COFFEE BREWER. 21. COORDINATE INSTALLATION OF ALL VALVES AND MIXING VALES WITH ACCESS PANEL. COORINATE WITH ARCHITECTURAL PLANS FOR SPECIFICATIONS OF WALL MOUNTED ACCESS PANNEL. QUEEN SUITE i 3" CW P-5 STAIRS REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 8 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 1.8 2017 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas aty • 6700 Antioch Plaza Bentonville Suite 300 Merriam, KS 66204 Phoenix San Francisco Philadelphia Atlanta Miami Tel: 913-262-9095 Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street • Lenexa, Kansas 66215 P 913 322 5150 • F 913 322 5155 www.AcerlusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 6 05/31/17 CCD #2 9 09/08/17 CCD #5 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES AN EXTENDED STAY HOTEL Project Manager: Checked By: CF/AR Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title PLUMBING WATER PLAN - FIRST FLOORS Sheet No. P-6 BRR Original printed on recycled paper 9 9/7/2017 4:37:30 PM 3"S TFB 3"S TFB -5 P-1 2"V FFB P-5 3"S TFB P2 1 1 /2" 5 a 3"S TFB TYPICAL FOURTH FLOOR WASTE & VENT SCALE: 1/4" = 1'-0" SUMP PUMP PIPING INSTALLED BELOW SLAB / oe Ni / / / / / SP ,01 co cn TURN PIPING UP THROUGH SLAB TO ABOVE FLOOR DRAIN, TERMINATE OVER FLOOR DRAIN WITH AIR GAP PER CODE 3"FD 6 3"S STACK FFA 3"S STACK FFA P-5 c 3' S STACK FFA 2"V TFA 3"S STACK FFA TYPICAL THIRD FLOOR WASTE & VENT SCALE: 1/4" = 1'-0" SUMP PUMP DET SCALE: II 1/2"HW& CW TO TUB/SHOWER ON 1ST AND 2ND FLOORS II II 1/2"HW& CW TO TUB/SHOWER ON 1ST AND 2ND FLOORS II 5 =112"HW&CW TO SINK ON 1STAND 2ND -1 FLOORS P- 1/2" HW & CW TO SINK ON - 1ST AND 2ND FLOORS 1/2"HW& CW TO WATER CLOSET ON 1ST AND 2ND FLOORS 1/2"HW& CW TO LAVATORY ON 1ST AND 2ND FLOORS 6 TYPICAL THIRD FLOOR WATER ) SCALE: 1/4" = 1'-0" 13"S STACK FFA; 3"S STACK FFA STACK FFA P-5 3' S STACK FFA 1 2"V TFA 3"S STACK FFA: 1 1/2" S 1 1/2" S 3"S STACK FFA TYPICAL SECOND FLOOR WASTE & VENT SCALE: 1/4" = 1'-0" 6" FIRE LINE (BY OTHERS) 3" CW UP THROUGH FLOOR. SEAL WATER TIGHT AND PROVIDE SHUT-OFF VALVE IN RISER EXPANSION TANK 1/2"HW& CW TO TUB/SHOWER ON 1ST AND 2ND FLOORS GAS METER BY UTILITY COMPANY (950 MBH) ENLARGED MECHANICAL ROOM PLAN SCALE: 1/4" =11-0" 1/2"HW& CW TO TUB/SHOWER ON 1ST AND 2ND FLOORS 1/2"HW&CW TO SINK ON 1ST AND 2ND FLOORS 1/2"HW& CW TO WATER CLOSET ON 1ST AND 2ND FLOORS 1/2"HW&CW TO SINK ON ::=7:1ST AND 2ND FLOORS 1/2"HW& CW TO LAVATORY ON 1ST AND 2ND FLOORS /5� TYPICAL FIRST FLOOR WATE SCALE: 1/4" = 1'-0" REVIEWED FOR E COMPLIANCE APPROVED SEP 2 8 2017 City/ of Tukwila UILDING l tStOPL 1 1/2" S 3"S STACK FFA RECEIVED CITY OF TUKWILA SEP 1 8 2017 PERMIT CENTER TYPICAL FIRST FLOOR WASTE & VENT SCALE: 1/4" = 1'-0" B R R Architect of Record: BRR Architecture, Inc. Kansas aty 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P 913 322 5150 0 F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 6 05/31/17 CCD #2 9 09/08/17 CCD #5 Project Name Woodspring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF/AR Drawn by: RC/MN/JR Document date: 02/25/2016 Project No. 31000057 Professional Seal EXPIRES: 09/21/17 Sheet Title PLUMBING ENLARGED PLANS Sheet No. P-10 0 BRR Original printed on recycled paper 5/24/2017 10:02:09 AM PLUMBING LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION ABBREVIATIONS —CFI— —NJ— —ply -04-- --{_ 4 GATE VALVE CHECK VALVE PRESSURE SOLENOID VALVE GLOBE VALVE (STRAIGHT PATTERN) BUTTERFLY VALVE BALL VALVE GAS COCK PLUG VALVE FLOOR CLEAN OUT WALL CLEAN OUT CLEAN OUT HOSE BIBB FREEZE PROOF WALL HYDRANT SHOWER HEAD. ELBOW DOWN ELBOW UP TEE UP TEE DOWN STRAINER UNION CAPCD FLEX PIPE 410 J Co,' (0,' REMARKS FLOOR DRAIN / AREA DRAIN FLOOR SINK ROOF DRAIN OVERFLOW ROOF DRAIN HOT WATER RECIRCULATION PUMP PLUMBING VEVT THRU ROOF POINT OF CONNECTION (CONNECT NEW TO EXISTING) PLUMBING EQUIPMENT DESIGNATION PLUMBING RISER OR DETAIL DESIGNATION SANITARY SEWER PIPING STORM SEWER PIPING VENT PIPING VENT PIPING (BELOW SLAB) COLD WATER PIPING HOT WATER PIPING COLD WATER PIPING (BELOW SLAB) HOT WATER PIPING (BELOW SLAB) HOT WATER RECIRCULATING PIPING GAS PIPING CONDENSATE PIPING AD AREA DRAIN, ACCESS DOOR AFC ABOVE FINISH CEILING AFG ABOVE FINISH GRADE AHU AIR HANDLING UNIT BFP BACKFLOW PREVENTER BOP BOTTOM OF SIPS BOS BOTTOM OF STRUCTURE CD CONDENSATE CO CLEANOUT CW DOMESTIC COLD WATER DD DECK DRAIN DN DOWN ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER FCO FLOOR CLEANOUT FFA FROM FLOOR ABOVE FFP FIRE P F OOR SINK G GAS (NATURAL) GCO GRADE CLEANOUT GPM GALLONS PER MINUTE HB HOSE BIBB HW DOMESTIC HOT WATER HWC HOT WATER CIRCULATION HWS HOT WATER SUPPLY IE INVERT ELEVATION LP LIQUIFIED PETROLEUM MBH 1000 BTU PER HOUR N/A NOT APPLICABLE ORD OVERFLOW ROOF DRAIN OST STORM OVERFLOW PD PUMP DISCHARGE PIV POST INDICATOR VALVE PRV PRESSURE REDUCING VALVE REV REVISION RPM REVOLUTIONS PER MINUTE RTU ROOF TOP UNIT SAN SANITARY ST STORM TFA TO FLOOR TFB TO FLOOR BELOWLVE 1W TEMPERED WATER UH UNIT HEATER V VENT PIPE VTR VENT THROUGH ROOF WCO WALL CLEANOUT WH WALL HYDRANT M BOOSTER PUMP TOWLE WHITNEY RD ORD VTR glk L XXX 104 FCO a {I WCO ET -1 co --I- AMTROL S ST _ V II b D VBF �� CW 1 HW — CWBF HWBF 0 — 0 I I v I 1 ZN1400-TX �I _ _ HWR 1 I GAS ] —ilk— FD DEFINITIONS: FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS." PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." 2 EXCEPT AS OTHERWISE NOTED, ALL SCHEDULED PLUMBING FIXTURES SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR. THE PLUMBING CONTRACTOR SHALL MAKE ALL ROUGH -IN AND FINAL CONNECTIONS TO ALL PLUMBING EQUIPMENT. 3 REFER TO PLUMBING FIXTURE SCHEDULE FOR PIPING RUNOUT SIZES TO INDIVIDUAL PLUMBING FIXTURES. 4 DO NOT ROUTE ANY PIPING OVER ELECTRICAL ROOMS, COMPUTER ROOMS, OR ELECTRICAL PANELS. 5 WATER PIPING INSTALLED IN EXTERIOR WALLS SHALL BE INSTALLED ON CONDITIONED SIDE OF INSULATION. 6 UNDERSLAB WATER PIPING SHALL BE TYPE 'K' SOFT DRAWN WITH NO JOINTS. 7 ALL DOMESTIC WATER PIPING IN CEILING SPACE SHALL BE ROUTED BELOW CEILING INSULATION. DO NOT INSTALL WATER PIPING ABOVE TOP FLOOR CEILING DRYWALL. 8 PROVIDE PRESSURE REDUCERS AS REQUIRED IN WATER SUPPLY LINES TO KEEP PRESSURE BELOW 70 PSI AT ALL OUTLETS. 9 PROVIDE PROPERLY SIZED WATER HAMMER ARRESTORS ON QUICK CLOSING VALVES. 10 PROVIDE APPROVED BACKFLOW PREVENTION OR ANTI -SIPHON DEVICES AT ALL FIXTURES THAT COULD CONTAMINATE THE POTABLE WATER SYSTEM. 11 PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS. LOCATE TRAP PRIMER VALVES IN ACCESSIBLE LOCATION. DO NOT LOCATE TRAP PRIMER VALVES OR PIPING IN AREAS ACCESSIBLE TO THE PUBLIC. 12 ALL WORK SHALL COMPLY WITH CURRENT FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES AS WELL AS THE CONSTRUCTION DOCUMENTS. REPORT ANY CONFLICTS TO THE ENGINEER AS SOON AS THEY ARE DISCOVERED. 13 REVIEW THE DRAWINGS AND SPECIFICATIONS PRIOR TO BIDDING JOB AND DURING CONSTRUCTION. EXCEPT AS OTHERWISE NOTED, PROVIDE ALL EQUIPMENT, MATERIALS, & LABOR FOR A COMPLETE PROJECT AS SHOWN IN THE DRAWINGS AND SPECIFICATIONS. DRAWINGS AND SPECIFICATIONS CARRY EQUAL IMPORTANCE AND ITEMS LISTED IN EITHER SHALL BE PROVIDED AS IF LISTED IN BOTH. ALSO REVIEW DETAILS AND RISER DIAGRAMS FOR ADDITIONAL ITEMS/INSTRUCTIONS WHETHER SPECIFICALLY REFERRED TO ON PLANS OR NOT. 14 DRAWINGS ARE DIAGRAMMATIC IN NATURE AND SHOW THE GENERAL INSTALLATION OF EQUIPMENT & MATERIALS IN RELATIONSHIP TO STRUCTURE & OTHER TRADES. THEY MAY NOT SHOW EVERY REQUIRED OFFSET, FITTING, ETC. FIELD VERIFY ACTUAL JOB CONDITIONS AND COORDINATE WORK WITH OTHER TRADES PRIOR TO BIDDING JOB AND PRIOR TO ORDERING EQUIPMENT, FABRICATION OF MATERIALS, OR STARTING WORK. DO NOT SCALE THE DRAWINGS. 15 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL ITEMS THAT AFFECT OTHER DISCIPLINES WITH THE CORRESPONDING CONTRACTOR AND THE GENERAL CONTRACTOR IF EQUIPMENT, MATERIALS, ETC. OTHER THAN THOSE SCHEDULED & SPECIFIED (PENDING PRE -APPROVAL) ARE FURNISHED. 16 CHANGE ORDERS WILL NOT BE GRANTED DUE TO LACK OF COORDINATION WITH JOB CONDITIONS AND/OR OTHER CONTRACTORS. 17 MAINTAIN ALL REQUIRED SERVICE, FRESH AIR, & ROOF EDGE CLEARANCES FOR ALL NEW AND EXISTING EQUIPMENT, AND PLUMBING VENTS. 18 UPON COMPLETION OF THE PROJECT PROVIDE AS -BUILT DRAWINGS TO THE OWNER, ARCHITECT, AND ENGINEER SHOWING EQUIPMENT, PIPING, ETC. THAT DIFFERS FROM CONSTRUCTION DOCUMENTS AS THEY ARE ACTUALLY INSTALLED. 19 THE RESPONSIBILITY OF EACH CONTRACTOR IS NOT LIMITED TO THEIR SPECIFIC DISCIPLINE'S DRAWING SHEETS. REFER TO OTHER DISCIPLINES' DRAWING SHEETS AS REQUIRED FOR ADDITIONAL INFORMATION/INSTRUCTIONS. 20 FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS. SLEEVE IN ENTIRETY WITH APPROPRIATE SLEEVE MATERIAL. FILE copy Permit o. Plan review approval is subject to errors and omissions. Approval of construction docurnents doc3 not cu soiize the violation of any adopted code or ord.na-:co. t tccef .ft of approved I"i id C. s a ► cond iionv is a ow1a cd: City of Tukwila BUILDING DIVISION REVISIONS No changes sh^lI r-odo to thr, ;cone of work withoLt Ow G pp MVP of Tukwila Building Division NOTE: Revisions will require a n^'.°/ ply n suhrnittal and may include additional plan review, NOTE: NO SUBSTITUTIONS OF VENDORS OR PRODUCT ON EQUIPMENT UNLESS APPROVED BY WOODSPRING SUITES, THE ARCHITECT AND THE OWNER. SEPARATE PERMIT REQUIRED FQF: ochanical Electrical ❑ Plumbing ❑ Gas Piping BUILD! l(1 I i,/i^1ON PLUMBING FIXTURE SCHEDULE (SIGNATURE) MARK FIXTURE TYPE MANFUACTURER MODEL CONSTRUCTION MATERIAL SIZE (IN) MOUNTING TRIM REMARKS FAUCETNALVE MFG. & MODEL STRAINER/ GRATE TYPE BP -1 BOOSTER PUMP TOWLE WHITNEY TW2000-15G-40 DUPLEX SYSTEM 20 ET -1 EXPANSION TANK AMTROL ST -42V FCO CLEANOUT ZURN ZN1400-TX CI W/NICKEL BRONZE STRAINER SEE PLANS FLOOR -- -- -- FD FLOOR DRAIN ZURN ZN415-5B CI W/NICKEL BRONZE STRAINER SEE PLANS FLOOR -- YES 16 FS FLOOR SINK ZURN Z610 -HD -90 CAST IRON SEE PLANS FLOOR -- YES -- LI LINT INTERCEPTOR SCHIER PRODUCTS PS -125-B POLYETHYLENE 19 P-1 WATER CLOSET GERBER VP -21-512 VITREOUS CHINA N/A FLOOR -- -- 1 P -1H WATER CLOSET GERBER VP -21-518 VITREOUS CHINA NA/ FLOOR -- A -- 1, 2 P-2 LAVATORY PROFLO PF1812UWH -- -- - COUNTER P188624LF POP-UP 3 P -2H LAVATORY PROFLO PF1812UWH -- -- COUNTER PEERLESS P 8:62, LF POP-UP 3, 4 P-3 TUB/SHOWER AQUARIUS AG6004TSRWH WITH ACRYLIC TOWEL BAR . GELCOAT 60X32 -- DELTA T14461 -- 5, 6, 8, 11, 12 P -3H TUB/SHOWER AQUARIUS AG6092TSLWH GELCOAT 60X32 -- T11861, RPW324HDF 14461, R11000, __ 5, 7, 8, 11, 12 P-4 SHOWER PRAXIS M6033 GELCOAT 60X33 -- DELTA T14261 5, 11 P -4H ROLL IN SHOWER COMFORT DESIGN XST6333 BF ADA 0.75 GELCOAT 63X34 -- T11861, RPW324HDF DELTA T14261, R11000, __ 5, 9, 10, 11, 12 P -4T TRANSFER SHOWER AQUARIUS G3698BF GELCOAT 39X39.5 -_ DELTAT14261, R11000, TI1861, RPW324HDF. - 5, 11 P-5 SINK MAINLINE MLD17213 STAINLESS STEEL 17X21 COUNTER DELTA 9959 -DST BASKET 13 P -5H SINK MAINLINE MLD17213 STAINLESS STEEL 17X21 COUNTER DELTA 9959 -DST BASKET 4, 13 P-6 LAVATORY ZURN Z5344 VITREOUS CHINA 20X18 WALL DELTA 523LF-HDF GRID 3, 4, 11, 14MOP P-7 BASIN/TRENCH ---- -- -- FLOOR DELTA 28C2063 -- 15 P-8 WASHING MACHINE BOX MAINLINE ML10499 -- -- WALL -- -- -- P-9 LAUNDRY SINK MUSTEE 26F DURASTONE 40X24 FLOOR DELTA 2133LF -- 13 P-10 HOSE BIBB WOODFORD 26C P-11 HOSE BIBB WOODFORD 17CP-12-MH 1.P-12 i TRENCH DRAIN ZURN ZS880-80 ZS880-60 STAINLESS STEEL 4.5X36 4.5X60 FLOOR 21 RD ROOF DRAIN ZURN Z100 CI W/POLY DOME SEE PLANS ROOF -- YES -- RP RECIRC PUMP GRUNDFOS UP26-96F '115V/1 PH SP SUMP PUMP ZOELLER BN145 115V/1PH TMV THERMOSTATIC MIXING VALVE SYMMONS 5-1000-W WALL TP -1 TRAP PRIMER PPP INC. PR -500 BRASS -- -- -- -- -- WCO CLEANOUT ZURN Z1446 STAINLESS SEE PLANS WALL WH -1, 2, 3 WATER HEATER LOCHINVAR SNR2001-100 93 GAL 18, 21 EWC ELECTRIC WATER COOLER ELKAY EZSTL8LC FRONT PUSH BUTTON, DOUBLE STATION, ADA COMPLIANT 115V/1 PH WALL ADA HEIGHT GENERAL FIXTURE ACCESSORY NOTES: 1. PROVIDE CARRIERS FOR ALL WALL HUNG WATER CLOSETS, URINALS, & LAVATORIES. 2. PROVIDE ALL ADA SINKS WITH REAR CENTERED DRAIN OPENINGS. 3. PROVIDE ALL ADA LAVATORIES & SINKS NOT PROTECTED BY AN ARCHITECTURAL SKIRT PANEL WITH UNDERSINK PIPING COVERS EQUAL TO TRUEBRO LAVGARD 2. 4. PROVIDE ALL ADA WATER CLOSETS & URINALS WITH THE FLUSH LEVER ON THE WIDE SIDE OF THE FIXTURE. SEE PLANS. FIXTURE REMARKS: 1. PROVIDE WITH CENTOCO 620 WHITE SEAT, MLB112DLF 12" SUPPLY, MLQTCRI9C'/ TURN STOP, NO -SEEP BOWL WAX & CLOSET BOLT KIT. 2. PROVIDE WHITE OFLC SEAT IN R/R 139. 3. 1.5GPM, PROVIDE ML507 P -TRAP, MLB112AF SUPPLIES, MLQTCRI9C % TURN STOPS. 4. PROVIDE & INSTALL ML102W INSULATION COVER WITH ONE P -TRAP AND TWO SUPPLY COVERS. 5. PROVIDE DANZE D11300BT VALVE FOR TUB AND SHOWER. PROVIDE DANZE D112000BT FOR SHOWER ONLY. 6. 1.5GPM SHOWERHEAD & SLIP JOINT TUB DIVERTER SPOUT. 7. 1.6GPM HANDHELD, 24" SLIDE BAR, 60" FLEX HOSE & SLIP JOINT DIVERTER SPOUT, DF596 SHOWER SEAT. 8. PROVIDE 35217 TIP TOE WASTE & OVERFLOW. 9. 1.6GPM HANDHELD, 24" SLIDE BAR, 60" FLEX HOSE. 10. PROVIDE SHOWER UNIT WITH GRAB BARS, FOLD UP SEAT, SHOWER CURTAIN AND ROD AND SHOWER DRAIN ROUGH -IN & INSTALLATION NOTES: 1. UNLESS OTHERWISE NOTED, PC SHALL FURNISH, INSTALL, & CONNECT ALL SCHEDULED PLUMBING FIXTURES. 2. INSTALLATION OF ADA FIXTURES SHALL MEET FEDERAL ADA STANDARDS. 3. SEE ARCHITECTURAL PLANS & ELEVATIONS FOR INSTALLATION HEIGHTS OF ALL PLUMBING FIXTURES. 4. PROVIDE TRAP PRIMERS TO SERVE ALL FLOOR DRAINS. 5. PLUMBING CONTRACTOR SHALL SUPPLY & INSTALL ALL ACCESSORIES, VALVES, WATER HAMMER ARRESTORS, ETC. NOT SCHEDULED OR CALLED OUT ON PLANS BUT REQUIRED TO MAKE THE PLUMBING SYSTEM COMPLETE. 6. UNLESS OTHERWISE NOTED IN REMARKS SECTION, FIXTURE ROUGH -IN & CONNECTION PIPING SIZES SHALL BE AS INDICATED IN ADJACENT TABLE. 5. PROVIDE ALL LAVATORY & SINK P -TRAPS WITH INTEGRAL CLEANOUT PLUGS. 6. UNLESS OTHERWISE NOTED IN REMARKS SECTION, PROVIDE ALL WATER FURNISHED WITH WHITE OPEN FRONT SEATS, INCLUDING COVERS. 7. UNLESS OTHERWISE NOTED, PIPING CONNECTION SIZES OF ALL FLOOR FLOOR SINKS, & CLEANOUTS SHALL MATCH PIPING RUNOUT SIZE SHOWN 8. SEE PLANS FOR ROOF DRAIN PIPING CONNECTION SIZES. 11. VERIFY CORRECT DIMENSIONS. 12. PROVIDE RIGHT OR LEFT HAND DRAIN AS REQUIRED. 13. PROVIDE WITH GUTLAF175 1.75GPM AERATOR, ML510 P -TRAP, MLB120AF MLQTCRI9C 1/4 TURN STOPS. 14. PROVIDE LEONARD 170 WHERE REQUIRED BY LOCAL CODE. 1 15. PROVIDE Z1996 -HH HOSE & HOSE HANGER. 16. PROVIDE WITH TRAP PRIMER CONNECTION. (� 17. CLEANOUT FITTING & PLUG TO BE PROVIDED IN ROUGH -Ie ; �r. cEIVED 18. 199MBTU 96% EFF, INCL 3" CONCENTRIC VENT KIT. �+ I' MAY 2 19. PROVIDE EXTENSION IF REQUIRED. 20. IF REQUIRED. PERMIT CENTER 21. ALTERNATE WATER HEATER: STATE SUFI-0199NEA 22. 36" LENGTH FOR TRANSFER SHOWER AND 60" LENGTH FOR ROLL -IN SHOWER. CLOSETS DRAINS, ON PLANS. SUPPLIES, LA 5 2017 PLUMBING FIXTURE TRAP WASTE VENT COLD WATER HOT WATER ABOVE GRADE BELOW GRADE WATER CLOSET -FLUSH TANK -- 3" 3" 2" 1/2" -- LAVATORY 1-1/2" 1-1/2" 2" 1-1/2" 1/2" 1/2" BATHTUB/SHOWER 2" 1-1/4" 2" 1-1/2" 1/2" 1/2" SINK -HAND, BAR, RESIDENTIAL KITCHEN 1-1/2" 1-1/2" 2" 1-1/2" 1/2" 1/2" SINK -COMMERCIAL KITCHEN 2 1-1/2" 2" 1-1/2" 3/4" 3/4" RESIDENTIAL CLOTHES WASHER/WASHER BOX 2" 2" 2" 1-1/2" 3/4" 3/4" ICE MAKER/ICE MAKER BOX -- -- -- -- 1/2" -- MOP BASIN/SERVICE SINK 3" 3" 3" 2" 3/4" 3/4" WALL HYDRANT/HOSE BIBB -- -- -- -- 3/4" -- 07Z B R R Architect of Record: BRR Architecture, Inc. Kansas aty Bentonville Phoenix San Francisco Philadelphia Atlanta Miami 6700 Antioch Plaza Suite 300 Merriam, KS 66204 Tel: 913-262-9095 Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street • Lenexa, Kansas 66215 P 913 322 5150 a F 913 322 5155 . www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its issue date and It is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by:. RC/M Docume 02/2 /JRREVIEWED FOR ME COMPLIANCE 'APPROVED Project 310 JUN_2 0 2017 0057 J Profess oval sell)! of Tukwila ila BUILDINCIDIVISION EXPIRES: 09/21/17 Sheet Title PLUMBING NOTES AND LEGENDS Sheet No. P-1 BRR Original printed on recycled paper MEW 5/24/2017 10:02:16 AM 8" SANITARY SEWER INVERT 4'- 8" BELOW F.F. COORDINATE DEPTH WITH CIVIL 0 3"RD REFETO CIVIL PLANS FOR CONTINUATION / STORAGE 3"RD REFETO CIVIL PLANS FOR CONTINUATION —71 J -- - DOUBLEQUEEN �\ | RESTR OM /L FITNESSEWC DOUBLE QUEEN SUITE HALL / VEND NG ACC QUEEN FAMILY SUITE |11y| / D"S (TYP) 4" CLEANOUT ip'5 / / \ \ DOU8LE' ' / ;,,T \ `` /OUBN \ GU0E �,l�1/; ;EI ' / \'v°�^ \.SE N , QUEENSUITE LOBBY |(0 DOUBLE. C>UEEN\SUITE 1, [_ uu| ` PLUMBING KEYNOTES (0 ,® ,®) 1. SEE RISER DETAIL 1 ON SHEET P8. 2. PROVIDE JR SM]TH MODEL 2420 FLOOR DRAIN WITH SEDIMENT BUCKET. SEE ARCI-HTECTURAL PLANS FOR TRENCH DETAIL. 3. REOUTE SUMP PUMP PIPING UNDERSLAB TO FLOOR DRAIN. NDIRECT OVER DRAIN WITH HALF GRATE. PROVIDE AIR GAP. 4. PROVIDE INDIRECT DRAIN CONDENSATE FROM FCU TO FLOOR DRAIN WITH 2" AIR GAP. PROVIDE FLOOR DRAIN WITH HALF GRATE. 5. PROVIDE INDIRECT DRAIN FOR VENDING MACHINES TO FLOOR SINK WITH 2" AIR GAP. PROVIDE FLOOR DRAIN WITH HALF GRATE. S. EXTEND 1/2" CW FROM TRAP PRIMER. CONNECT CW FOR PRIMER SYSTEM TO NEAREST 1" CW PIPE OR LARGER. 7. SEE RISER DETAIL 2 ON SHEET P8. 8. SEE RISER DETAIL 3 ON SHEET P8. U. SEE RISER DETAIL 4 ON SHEET P8. 10. SEE RISER DETAIL 5 ON SHEET P8. 11. SEE RISER DETAIL 6 ON SHEET P8. 12. SEE RISER DETAIL 7 ON SHEET P8. 13. SEE RISER DETAIL 8 ON SHEET P8. 14. PROVIDE 4"W TO LINT TRAP AND CONNECT TO BUILDING SEWER. 4" INLET/OUTLETS PROVDE RISERS AS REQUIRED. 15. SEE RISER DETAIL 9 ON SHEET P8. 16. SEE RISER DETAIL 10 ON SHEET P8. 17. CONNECT DISHWASHER DRAIN LINE TO P-5 P -TRAP WITH DISHWASHER CONNECTON. TYPICAL FOR ALL STUDIOS. 3"RD CONNECTED TO ROOF DRAIN REFERTO ARCHITECTURAL PLAN FOR DETAILS 3"RD REFER TO CIVIL PLANS FOR CONTINUATION VESTIBULE VESTIBULE TRAINING TRAINING FUmRST FLOOR WASTE & VENT DRAINAGE FIXTURE UNIT FIXTURE QUANTITY WASTE TOTAL WATER CLOSET 1 4 4 LAVATORY 1 1 1 BATHROOM GROUP 123 5 615 SINK 123 2 246 LAUNDRY SINK 1 2 2 4" FLOOR DRAIN 3 6 18 3" FLOOR DRAIN 3 5 15 2" FLOOR DRAIN 2 2 4 PUBLIC WASHING MACHINE 6 3 18 EXTRACTORS 2 6 12 TRENCH DRAIN 1 6 6 TOTAL 941 3"RD CONNECTE TO ROOF DRAIN REFERTO ARCHITECTURAL PLAN FOR DETAILS 3"RD REFETO CIVIL PLANS FOR CONTINUATION QUEEN \ SUITE N \ QUEEN \ SUITE PROVIDE CLEANOUTS ^ o^��v/���_��u_���.�����n�� �T����� �8������ ALL ^�x , THE ��—x^��— ��^ WASTE RISERS \ `.`.+/ ` \ `` ` STAIRS .`. |«m| INVERT 1.%yBELOW F.F. 4" CLEANOUT RECEIVED CITY OF TUKWILA MAY 25 2017 PERMIT CENTER Architect of Record: BRR Architecture, Inc x=saso* . 6700 Antioch Plaza Bentonville Suite 300 Phoenix . Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami . Fax: 913-262-9044 Consultants E US CONSULTING GROUP, LLC 14817 We95th Street v Lenexa, Kansas 662o ,nozumoo • rnnm22me Copyright Notice _ _ This drawing was prepared for use on a specific site contemporaneously with Its issue date and it Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revision NO. DATE DESCRIPTION 5 04/18/17 CCD #1 Project Name ---------m-----um Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • **(° ��^��������00�N�� ��������4�N���0N���� SUITES' AN EXTENDED STAY HOTEL Project Manager: Checked By: � • bREVIEVVED FOR OWE COMPLIANCE umentdAPPROVED o /25/2016 JUN 2 0 2017 ject Nu. DIVISION EXPIRES: 09/21 /17 Sheet Title PLUMBING WASTE AND VENT PLAN — Sheet No. P-2 BRR Original printed on recycled paper 5/24/2017 10:02:22 AM u".11".111, STAIRS DOUBLE QUEEN SUITE DOUBLE QUEEN SUITE UTILITY :: ••,ROOM DOUBLE QUEEN.-..... SUITE DOUBLE QUEEN FAMILY SUITE :>DELUXE KING / DOUBLE QUEEN SUITE \ P-5;' \ \\ \. / \ DOUBLE \QUEEN /'SUITE 12151 \ / (TYP) P-5 P-5: DELUXE CORNER SUITE QUEEN SUITE ACC. DOUBLE QUEEN SUITE Q \ SUITE/" V A12121%\ \. \..., QUEEN SUITE \ \ / // / \ \ '‘• // /' ,/>').\1 /, /// / QUEEN\ \\ / / /�� /SUITE \ /• SECOND FLOOR WASTE & VENT SIGNATURE SCALE: 1/8" = 1'-0" PLUMBING KEY NOTES (O,CD,®) 1. CONNECT DISHWASHER DRAIN LINE TO P-5 P -TRAP WITH DISHWASHER CONNECTION. TYPICAL FOR ALL STUDIOS. P-2\< P-1 / QUEEN \ SUITE \ 12051 \P-2 P-5; \ \ • ` / \\� P-2 / \ QUEEN "SUITE 1'2041 P-1 �.P-2 STAIR / , j \\< //\,fi > '\<< RECEIVED CITY OF TUKWILA MAY 252017 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas City 1 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street • Lenexa, Kansas 66215 P 913 322 5150 0 F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with its Issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 Ajt, WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Do ate. o /27IgWED FOR CODE COMPLIANCE Project No. APPROVED 0009 .472 0 2017 PrdiessionalSeal City of Tukwila BUI VISION EXPIRES: 09/21/17 Sheet Title PLUMBING WASTE AND VENT PLAN - 2ND FLOOR Sheet No. P-3 BRR Original printed on recycled paper 5/24/2017 10:02:28 AM STAIRS DOUBLE QUEEN SUITE UTILITY ROOM 1 DOUBLE .......................... QUEEN SUITE 3231 DOUBLE QUEEN 13191 CORRIDOR CORRIDOR P-2 P-1 DOUBLE........ QUEEN SUITE_..._...._.. ACC. DELUXE KING SUITE ACC. QUEEN SUITE QUEEN \ SUITE THIRD FLOOR WASTE & VENT - SIGNATURE SCALE: 1/8" = 1'-0" PLUMBING KEY NOTES (O,O,O) 1. CONNECT DISHWASHER DRAIN LINE TO P-5 P -TRAP WITH DISHWASHER CONNECTION. TYPICAL FOR ALL STUDIOS. %"\ QUEENS SUITE \ 13081//\ d0, QUEEN? SUITE 13061 ,P-2 B R R Architect of Record: BRR Architecture, Inc. Kansas City • 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P 913 322 5150 G F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/ Docu 02 VIEWED FOR EtyCOMPLIANCE APPROVED - 31 00057 JUN 2 0 2017 - `' Prof ; sionadSt t - of -Tukwila- - BUILDING fTukwila- BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 252017 PERMIT CENTER EXPIRES: 09/21/17 Sheet Title PLUMBING WASTE AND VENT PLANS - 3RD FLOOR Sheet No. P-4 0 BRR Original printed on recycled paper 5/24/2017 10:02:36 AM STAIR DOUBLE QUEEN :SUITE DOUBLE QUEEN SUITE 14291 �TYP) 3"RD CONNECTED TO ROOF DRAIN ! REFER TO ARCHITECTURAL! PLAN FOR DETAILS UTILITY ROOM 14401 DELUXE KING DOUBLE QUEEN SUITE DOUBLE QUEEN FAMILY SUITE "iqj o CORRIDOR CORRIDOR P-1 H P -3H P-1 H P-1 P-2 P-2 \ 7, /DOUBLE QUEEN' SUITE / QUEEN SUITE QUEEN SUITE QUEEN SUITE DOUBLE QUEEN SUITE / DELUXE / CORNER SUITE \p-2 SUITE 1 420 1 1 P-2` P-1 14 PLUMBING KEY NOTES (O,®,®) 1. CONNECT DISHWASHER DRAIN LINE TO P-5 P -TRAP WITH DISHWASHER CONNECTION. TYPICAL FOR ALL STUDIOS. 4.8 1 412 1 ,I� FOURTH FLOOR WASTE & VENT SIGNATURE SCALE: 1/8" = 1'-0" QUEEN SUITE\w'\\�`< \ 14041 :, //; QUEEN j \ SUITE \ 1402.1 •/ P-2\ P-1 .r STAIR V� 14501 / / RECEIVED CITY OF TUKWILA MAY 252017 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas City • 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street 4 Lenexa, Kansas 66215 P 913 322 5150 4 F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a speciflc site contemporaneously with Its Issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • �s WOODSPRING SUITES' AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn RCI Docu 02/ V: REVIEWED FOR SDE COMPLIANCE ntda 5/200APPRQVED Proje 31 11 u t No. 00057 Profe M, ING EXPIRES: 09/21/17 Sheet Title PLUMBING WASTE AND VENT PLANS - 4TH FLOOR Sheet No. p.-5 0 BRR Original printed on recycled paper 5/24/2017 10:02:48 AM SEE SITE PLAN FOR CONTINUATION OF DOMESTIC AND FIRE PROTECTION WATER (9) P-11 18" AFG u STORAGE • ACC QUEEN FAMILY SUITE N FITNESS (TYP) 3" CW 2 1/2" HW 1-1/2"HWR FROM -THIRD FLOOR P-5 : �> QUEEN!, SUITE LOBBY I X3/4" CW it P-10 DELUXE CORNER SUITE ADJOINING' ROOM ` �) \P-2,�:.> P-1 P-11 18" AFG 3/4" CW 3/4" HW '(TYP) 1/2" CW 3/4" CW TRAINING P-5 VESTIBULE / / ,k::::.`.:;I / \ / • DOUBLE / QUEEN ; \ / SUITE j // • 11121 ,i *\ \ / \ �. NOTES: 1. PROVIDE STAND PIPE FIRE PROTECTION SYSTEM IN STAIRWELL PER CITY REQUIREMENTS. 2. PROVIDE DRY PIPE FIRE PROTECTION SYSTEM IN ATTIC. P-2 3 FIRST FLOOR DOMESTIC WATER PLAN SIGNATURE / SCALE: 1 /8" = 1'-0" WATER FIXTURE UNIT FIXTURE QUANTITY WATER TOTAL WATER CLOSET 1 2.2 2.2 LAVATORY 1 0.7 0.7 BATHROOM GROUP 123 3.6 442.8 SINK 123 1.4 172.2 LAUNDRY SINK 1 1.4 1.4 WASHERS 6 3 18 COMMERCIAL WASHER 2 4 8 ICE MACHINE 1 6 6 HOSE BIBB 2 2.5/1 3.5 MOP SINK FAUCET 1 3 3 TOTAL 657.8 RUN 1/2" CROSS-LINKED POLYETHYLENE FROM MANIFOLD TO EACH PLUMBING FIXTURE ON BOTH FIRST AND SECOND FLOORS. PEX MANIFOLDS SHALL BE ZURN, PROVIDE PEX COMPATIBLE COPPER MANIFOLDS AND WALL STUBS. PEX SUPPLY LINES SHALL BE HOMERUNS FROM THE MANIFOLD LOCATED ABOVE THE CORRIDOR CEILING TO THE OUTLET. MANIFOLDS IN CORRIDORS TO BE ACCESSIBLE. PLUMBING KEY NOTES CD® ) 1.. 2 1/2" COLD AND HOT WWATER UP TO 3RD FLOOR CEILING. 2. 2 1/2" COLD AND HOT WATER UP FROM 1ST FLOOR CEILING. 3. PROVIDE COPPER MANIFOLD FOR WATER DISTRIBUTION. PROVIDE ISOLATION VALVES UP STREAM OF MANIFOLD FOR COMPLETE SYSTEM ISOLATION. (TYPICAL) MANIFOLDS TO BE INSTALLED IN CORRIDOR. 4. REFER TO ARCHITECTS DETAIL FOR MOUNTING HEIGHTS OF TUB/SHOWER FAUCET AND CONTROLS. (TYPICAL) 5. ROUTE 1/2" TO UNIVERSAL FLUSH MANIFOLD (BY OWNER). COORDINATE WITH OWNER FOR EXACT MOUNTING HEIGHTS AND INSTALLATION DETAILS. 6. DROP 1-1/2" COLD AND HOT WATER DOWN IN WALL TO WASHERS. HOLD TIGHT TO CORNER @ STAFF LAUNDRY. EXTEND 3/4" SUPPLY LINES TO MOP FAUCET. 7. EXTEND 3/4" CW TO DRYER FOR FIRE SUPPRESSION SYSTEM INSIDE DRYER. PROVIDE VALVE AND SPIGOT. SPIGOT TO BE INSTALLED ON CEILING. INSTALL LINE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. 8. PROVIDE RAYCHEM SELF REGULATING PROTECTION SYSTEM ON HOSE AT CONNECTION FROM HOSE BIBB TO COMMERCIAL DRYER. SIZE AND INSTALL PER MANUFACTURER'S INSTRUCTIONS WITH 3/4" INSULATION SURROUNDING PIPE AND HEAT TRACE. CONNECT TO ADJACENT ELECTRICAL OUTLET BY E.C. 9. MOUNT HOSE BIBB AT 40" A.F.F. SEE ARCHITECTURAL PLANS. 10. DROP 3/4" HW/CW DOWN IN WALL TO WASHER BOX. 11. PROVIDE CPVC EXPANSION JOINT PER MANUFACTURER'S INSTRUCTIONS. SIMILAR TO FLEXICRAFT MODEL CP. INSTALL AS REQUIRED THROUGHOUT WATER SYSTEM. 12. SEE RISER DETAIL 1 ON SHEET P-9. 13. SEE RISER DETAIL 2 ON SHEET P-9. 14. SEE RISER DETAIL 3 ON SHEET P-9. 15. SEE RISER DETAIL 4 ON SHEET P-9. 16. SEE RISER DETAIL 5 ON SHEET P-9. 17. ROUTE GAS TO DRYERS PER MANUFACTURERS INSTRUCTIONS. 18. CONNECT DISHWASHER SUPPLY TO HOT WATER SUPPLY OF P-5. TYPICAL FOR ALL STUDIOS. 19. DO NOT ROUTE WATER IN EXTERIOR WALLS. WATER CLOSET SUPPLY TO BE THROUGH FLOOR. 20. TAP 1/2" COLD WATER OFF P -5H WATER SUPPLY FOR COFFEE BREWER. 21. COORDINATE INSTALLATION OF ALL VALVES AND MIXING VALES WITH ACCESS PANEL. COORINATE WITH ARCHITECTURAL PLANS FOR SPECIFICATIONS OF WALL MOUNTED ACCESS PANNEL. 11031 RECEIVED CITY OF TUKWILA MAY 252017 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas City 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 951h Street ® Lenexa, Kansas 66215 P9133225150 ® F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and It is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • WOODSPRING SUITES' AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: /4R OCunEMIEWED FOR /MEOW APPRnvFn rofessional Seal - City of -Tukwila - BUILDING DIVISION EXPIRES: 09/21/17 Sheet Title PLUMBING WATER PLAN - FIRST FLOORS Sheet No. P-6 BRR Original printed on recycled paper 5/24/2017 10:02:56 AM 1-1/2"HWR DOWN TO FIRST FLOOR STAIRS DOUBLE QUEEN SUITE UTILITY ROOM DELUXE KING SUITE DOUBLE QUEEN SUITE DOUBLE QUEEN._._„ SUITE DOUBLE QUEEN L....FAMILY SUITE:::::: 13191 .... RUN 1/2" CROSS-LINKED POLYETHYLENE FROM MANIFOLD TO EACH PLUMBING FIXTURE ON BOTH THIRD AND FOURTH FLOORS. PEX MANIFOLDS SHALL BE ZURN, PROVIDE PEX COMPATIBLE COPPER MANIFOLDS AND WALL STUBS. PEX SUPPLY LINES SHALL BE HOMERUNS FROM THE MANIFOLD LOCATED ABOVE THE CORRIDOR CEILING TO THE OUTLET. MANIFOLDS IN CORRIDORS TO BE ACCESSIBLE. "HALL 13361 P-2 \t. . P-1' \. 2 1/2" CWS 2 1/2" HW—if 2 1/2" CW 2 1/2" HW 2 1/2" HW--' u P-2 \P-1 (TYP) (TYP) P -3H _ P -2H P -4T QUEEN SUITE 13341 QUEEN SUITE DOUBLE QUEEN._....... SUITE ACC. DELUXE KING SUITE DOUBLE (QUEEN SUITE 14 i :P QUEEN /j SUITE / \ �312�\ ... � 14THIRD FLOOR DOMESTIC WATER PLAN SIGNATURE SCALE: 1/8" = 1'-O" PLUMBING KEY NOTES e®10) 1. 2 1/2" COLD AND HOT WATER UP FROM 1ST FLOOR CEILING. 2. PROVIDE COPPER MANIFOLD FOR WATER DISTRIBUTION. PROVIDE ISOLATION VALVES UP STREAM OF MANIFOLD FOR COMPLETER SYSTEM ISOLATION. (TYPICAL) MANIFOLDS TO BE INSTALLED IN COORIDOR. 3. REFER TO ARCHITECTS DETAIL FOR MOUNTING HEIGHTS OF TUB/SHOWER FAUCET AND CONTROLS. (TYPICAL) 4. PROVIDE CPVC EXPANSION JOINT PER MANUFACTURER'S INSTRUCTIONS, SIMILAR TO FLEXICRAFT MODEL CP. INSTALL AS REQUIRED THROUGHOUT WATER SYSTEM. 5. SEE RISER DETAIL 1 ON SHEET P-9. 6. SEE RISER DETAIL 2 ON SHEET P-9. 7. CONNECT DISHWASHER SUPPLY TO HOT WATER SUPPLY OF P-5. TYPICAL FOR ALL STUDIOS. 8. DO NOT ROUTE WATER IN EXTERIOR WALLS. WATER CLOSET SUPPLY TO BE THROUGH FLOOR. ROUTE 3/4" COLD WATER LINE UP TO ROOF FOR P-1 1 HOSE BIBB. INSTALL HOSE BIBB ON ROOF PARAPET. COORDINATE AROUND EXISTING CONDITIONS AND VERIFY EXACT HOSE BIBB LOCATION. Act 2 1/2" HW 45'/ / \ QUEEN .....,\1 /SUITE \�/;°\ \ ......., \‘; /, QUEEN\ j \ SUITE. " 1302•( / / RECEIVED CITY OF TUKWILA MAY 252011 PERMIT CENTER B R R Architect of Record: BRR Architecture, Inc. Kansas ary 6700 Antioch Plaza Bentonville Suite 300 Phoenix Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street 0 Lenexa, Kansas 66215 P 913 322 5150 ® F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with its Issue date and it Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 1 09/06/16 ADD #1 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR .tz VIEWED FOR Document date: }DE COMPLIANCI 02/25/2016 APPROVED Project No. _ JUN a O -2Q17 31000057 j Professional Seal City of Tukwjf j BUILDING DIVIt EXPIRES: 09/21/17 Sheet Title PLUMBING WATER PLANS - 3RD FLOOR Sheet No. P-7 BRR Original printed on recycled paper 5/24/2017 10:03:07 AM �1 P-5 1 1/2" S (TYP) P-5 to i>7 P-5 P-5 1I II II II II FCO NOTES 1 DOUBLE SANITARY TEE FITTING IS NOT TO BE USED. USE DOUBLE SANITARY WYE OR SINGLE FITTINGS. 2 PROVIDE CLEANOUTS AT THE BASE OF ALL WASTE RISERS. 3 AT KITCHEN SINKS IN GUESTROOM AREAS (P-5 AND P -5H), COORDINATE AND INSTALL THE HUB OF THE 3" WASTE STACKS ABOVE CEILINGS OR BELOW FLOORS. 4 GENERAL CONTRACTOR AND PLUMBING CONTRACTOR TO COORDINATE WITH OTHER TRADES TO ENSURE ADEQUATE SPACE FOR PIPING SYSTEMS. FD II II II > 11 N II II II II II II II I1 I 1I 11 11> IIN II II II II II FD II > II 4 II II 11 II P-5 r in RESTROOM RESTROOM GROUP STACK SCALE: NOT TO SCALE II II II II I1 II II SINGLE RESTROOM �6\ GROUP STACK SCALE: NOT TO SCALE WCO P-1 H 11 11 II 11 II II 11 11 11 II 11 II > II N II 11 11 11 11 II > II II 11 II II RESTROOM GROUP STACK SCALE: NOT TO SCALE tl P -2H II I I I cn 11 M P -2H EWCO P-1 H P-1 H 3" S P-1 H P-1 H k,,s WATER CLOSET (5) & LAVATORY STACK SCALE: NOT TO SCALE S WCO lor-3" S P-5 P-1 II P-2 P-5 P-2 M 0) M P-5 P-5 P-2 \ \ \\ \ P-5 2"S 3"S 11 11 II WCO 11 f d" Z. - 1I 13" V II 11 II F0-5 S r --3" 114;i5 P-5 1/(-3" S II P-5 05 4"S 0) M FD RESTROOM GROUP STACK & MECHANICAL ROOM SCALE: NOT TO SCALE TYPICAL BACK TO BACK SINKS TYPICAL SINKS 43 SCALE: NOT TO SCALE �� SCALE: NOT TO SCALE C\ 11 > 11 M II 11 P-3, P -3H 1 1 OR P-4, P -4H I I 1 1/2" S M P-3, P -3H OR P-4, P -4H 1 1/2" S 0) ih P-3, P -3H OR P-4, P -4H 1 1/2" S 0) M P-3, P -3H OR P-4, P -4H 1 1/2" S WCO �2 TYPICAL TUB/SHOWERS SCALE: NOT TO SCALE RESTROOM GROUP STACK SCALE: NOT TO SCALE 3.J i' II II 11 11 11 P-2 0) cn P-2 WCO P-1 P-2 P-1 P-1 P-1 WCO B R R Architect of Record: BRR Architecture, Inc. Kansas City i 6700 Antioch Plaza Bentonville Suite 300 Phoenix i Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACE RTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P 913 322 5150 4 F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its issue date and It is not suitable for use on a different project site or at a later time. Use of thls drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION 5 04/18/17 CCD #1 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 WOODSPRING SUITES AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: 02/25/2016 IRE CODEOMPLIANCE AST fikk City of T BUILDIN RECEIVED P-1 CITY OF TUKWILA MAY 2 5 2017 PERMIT CENTER TYPICAL BACK TO.BACK WATER CLOSETS & LAVATORIES SCALE: NOT TO SCALE EXPIRES: 09/21/17 Sheet Title PLUMBING WASTE & VENT RISERS Sheet No. P-13 0 BRR Original printed on recycled paper 6/14/2017 1:07:22 PM WH -3 200 MBH 1 1/4" G 2" G 1 1/4" G 1 1/2" G 1 1/2" G WH -2 200 MBH GAS METER 950 MBH TOTAL DEVELOPED LENGTH OF 225 FT. WH -1 200 MBH (- GAS RISER \ SCALE: NOT TO SCALE 3/4"CW WATER MAINS IN HALLWAY SEE PLAN FOR SPECIFIC SIZES PROVIDE WATER HAMMER ARRESTORS AT EACH WASHER CONNECTION PUBLIC LAUNDRY WATER SCALE: NOT TO SCALE 1-1/2"G TO STAFF LAUNDRY DRYERS (2)AT175EACH PEX PIPING TO BE INSTALLED AS HOMERUNS TO FIXTURES (ABSOLUTELY NO SPLICES, NO JOINTS) WATER PIPING TO BE COPPER OR CPVC NOTES: 1. GENERAL CONCTRACTOR AND PLUMBING CONTRACTOR TO COORDINATE WITH OTHER TRADES TO ENSURE ADEQUATE SPACE FOR PIPING SYSTEMS. 2. MANIFOLDS TO BE INSTALLED IN CORRIDOR. 3. WATER SHUT-OFF REQUIRED FOR EACH FIXTURE OR A UNIT SHUT-OFF MAY BE PROVIDED AND SHUT-OFF VALVES ARE REQUIRED TO EACH APPLIANCE OR MECHANICAL DEVICE PER 606.2 OF THE IPC 6\ MANIFOLD DETAIL SCALE: NOT TO SCALE 1 1/2" G 2 1/2" G 3" HW 1 1/2" HW 3" CW 1 1/2" CW 1 1/2" HW P-5 1 1/2" CW u CHECK VALVE (TYP) NORMALY CLOSED VALVE FOR BYPASS LOOP 1-1/2"HW (140F) SEE FLOOR PLAN FOR CONTINUATION SHUT-OFF VALVE (TYP) 3"HW (120F) SEE FLOOR PLAN FOR CONTINUATION 1-1/2"HWR SEE FLOOR PLAN FOR CONTINUATION 3"CW SEE FLOOR PLAN FOR CONTINUATION TMV 3"HW 3"CW WATER METER CONFIRM WITH CIVIL AND UTILITY RPZ BACKFLOW ASSEMBLY 3/4" HWC ✓i WATER MAINS IN HALLWAY SEE PLAN FOR SPECIFIC SIZES •NICA \Ac 11/2"CW 1 1/2" HW 3/4" C1" 3/4" HW 7/2„7�2'h,� 1/2" TEMPERING VALVE EQUAL TO BRADLEY TMV25 FOR OWNER SUPPLIED UNIVERSIAL FLUSH MANIFOLD 1/2" TEMPERED WATER TO UNIVERSAL FLUSH MANIFOLD COORDINATE FINAL LOCATION WITH OWNER `3/4"CW TO DRYERS 3" DOMESTIC WATER SERVICE MECHANICAL ROOM WATER SCALE: 6" FIRE LINE (BY OTHERS) P-8 1" (TYP) SHUTOFF VALVE (TYP) STAFF LAUNDRY WATER P-9 1/2" TO HOSE BIBB TO BE LOCATED P-7 BESIDE P-9 CHECK VALVE (TYP) 1-1/2" CW & HW 1/2" HW SCALE: NOT TO SCALE P-5 RUN 1/2" POLYETHYLENE P-5 FROM MANIFOLD TO P-5 EACH FIXTURE WATER MAINS IN HALLWAY SEE PLAN FOR SPECIFIC SIZES 002 TYPICAL BACK TO BACK SINK WATER SCALE: NOT TO SCALE CORRECTION LTR# P&17 WATER MAINS IN HALLWAY SEE PLAN FOR SPECIFIC SIZES 0072 RECEIVED CITY OF TUKWILA JUN 16 2017 P-3 PERMIT CENTER P-2 P-1 P-1 RUN 1/2" P-2 POLYETHYLENE P-3 FROM MANIFOLD TO EACH FIXTURE P-3 P-2 P-2 P-3 TYPICAL BACK TO BACK WATER SCALE: NOT TO SCALE B R R Architect of Record: BRR Architecture, Inc. Kansas city • 6700 Antioch Plaza Bentonville Suite 300 Phoenix , Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P9133225150 ® F9133225155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE 5 04/18/17 7 06/07/17 DESCRIPTION CCD #1 CCD#3 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • t4.* WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: REVIEWED FOR CODErOGIAPLIANCE E r000n7 imeana,N11 City of Tu JILDIN 06/07/17 EXPIRES: 09/21/17 Sheet Title PLUMBING DOMESTIC WATER RISERS Sheet No. P-9 0 BRR Original printed on recycled paper BRASS BALL VALVE 4i: +oo 0 0 0 __ NE`s J) CORRIDOR MANIFOLD TO BE INSTALLED ABOVE ABOVE CORRIDOR N—(2) LAYERS 5/8" FIRE RATED GYPSUM BOARD NOTES: 1. GENERAL CONCTRACTOR AND PLUMBING CONTRACTOR TO COORDINATE WITH OTHER TRADES TO ENSURE ADEQUATE SPACE FOR PIPING SYSTEMS. 2. MANIFOLDS TO BE INSTALLED IN CORRIDOR. 3. WATER SHUT-OFF REQUIRED FOR EACH FIXTURE OR A UNIT SHUT-OFF MAY BE PROVIDED AND SHUT-OFF VALVES ARE REQUIRED TO EACH APPLIANCE OR MECHANICAL DEVICE PER 606.2 OF THE IPC 6\ MANIFOLD DETAIL SCALE: NOT TO SCALE 1 1/2" G 2 1/2" G 3" HW 1 1/2" HW 3" CW 1 1/2" CW 1 1/2" HW P-5 1 1/2" CW u CHECK VALVE (TYP) NORMALY CLOSED VALVE FOR BYPASS LOOP 1-1/2"HW (140F) SEE FLOOR PLAN FOR CONTINUATION SHUT-OFF VALVE (TYP) 3"HW (120F) SEE FLOOR PLAN FOR CONTINUATION 1-1/2"HWR SEE FLOOR PLAN FOR CONTINUATION 3"CW SEE FLOOR PLAN FOR CONTINUATION TMV 3"HW 3"CW WATER METER CONFIRM WITH CIVIL AND UTILITY RPZ BACKFLOW ASSEMBLY 3/4" HWC ✓i WATER MAINS IN HALLWAY SEE PLAN FOR SPECIFIC SIZES •NICA \Ac 11/2"CW 1 1/2" HW 3/4" C1" 3/4" HW 7/2„7�2'h,� 1/2" TEMPERING VALVE EQUAL TO BRADLEY TMV25 FOR OWNER SUPPLIED UNIVERSIAL FLUSH MANIFOLD 1/2" TEMPERED WATER TO UNIVERSAL FLUSH MANIFOLD COORDINATE FINAL LOCATION WITH OWNER `3/4"CW TO DRYERS 3" DOMESTIC WATER SERVICE MECHANICAL ROOM WATER SCALE: 6" FIRE LINE (BY OTHERS) P-8 1" (TYP) SHUTOFF VALVE (TYP) STAFF LAUNDRY WATER P-9 1/2" TO HOSE BIBB TO BE LOCATED P-7 BESIDE P-9 CHECK VALVE (TYP) 1-1/2" CW & HW 1/2" HW SCALE: NOT TO SCALE P-5 RUN 1/2" POLYETHYLENE P-5 FROM MANIFOLD TO P-5 EACH FIXTURE WATER MAINS IN HALLWAY SEE PLAN FOR SPECIFIC SIZES 002 TYPICAL BACK TO BACK SINK WATER SCALE: NOT TO SCALE CORRECTION LTR# P&17 WATER MAINS IN HALLWAY SEE PLAN FOR SPECIFIC SIZES 0072 RECEIVED CITY OF TUKWILA JUN 16 2017 P-3 PERMIT CENTER P-2 P-1 P-1 RUN 1/2" P-2 POLYETHYLENE P-3 FROM MANIFOLD TO EACH FIXTURE P-3 P-2 P-2 P-3 TYPICAL BACK TO BACK WATER SCALE: NOT TO SCALE B R R Architect of Record: BRR Architecture, Inc. Kansas city • 6700 Antioch Plaza Bentonville Suite 300 Phoenix , Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 95th Street ® Lenexa, Kansas 66215 P9133225150 ® F9133225155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a specific site contemporaneously with Its Issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE 5 04/18/17 7 06/07/17 DESCRIPTION CCD #1 CCD#3 Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • t4.* WOODSPRING SUITES" AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MN/JR Document date: REVIEWED FOR CODErOGIAPLIANCE E r000n7 imeana,N11 City of Tu JILDIN 06/07/17 EXPIRES: 09/21/17 Sheet Title PLUMBING DOMESTIC WATER RISERS Sheet No. P-9 0 BRR Original printed on recycled paper 5/24/2017 10:03:25 AM 3" V /4� TYPICAL FOURTH FLOOR WASTE & VENT vy SCALE: 1/4" = 1'-0" SUMP PUMP PIPING INSTALLED BELOW SLAB'/j M SP 3"S STACK FFA P-5 3' S STACK FFA 3"S STACK FFA 3"S STACK FFA 2"V TFA 3"S STACK FFA TYPICAL THIRD FLOOR WASTE & VENT SCALE: 1/4" =11-0" TURN PIPING UP THROUGH SLAB TO ABOVE FLOOR DRAIN, TERMINATE OVER FLOOR DRAIN WITH AIR GAP PER CODE (o SUMP PUMP DETAIL y SCALE: 1/2"HW& CW TO V 11 TUB/SHOWER ON 1ST AND 2ND FLOORS ['pc, P-5 1/2"HW&CW TO SINK ON 1ST AND 2ND FLOORS 3"FD 1/2"HW& CW TO TUB/SHOWER ON 1ST AND 2ND . FLOORS 11 P- 1/2"HW&CW TO SINK ON 1ST AND 2ND FLOORS 1/2"HW& CW TO WATER CLOSET ON 1ST AND 2ND FLOORS TYPICAL THIRD SCALE: 1/4" = 1'-0" 1/2"HW& CW TO LAVATORY ON 1ST AND 2ND FLOORS LOOR WATER 3"S STACK FFA; • 3"S STACK FFA P-5 3' S STACK FFA 3"S STACK FFA 1 1/2" S 1 1/2" 3"S STACK FFA TYPICAL SECOND FLOOR WASTE & VENT SCALE: 1/4" =11-0" 6" FIRE LINE (BY OTHERS) 2 3" CW UP THROUGH FLOOR. SEAL WATER TIGHT AND PROVIDE SHUT-OFF VALVE IN RISER An 'r 3"CW BP -1 1-1/2'HWR 3' HW 120F EXPANSION TAN K 3" CW TMV 1 1/4" G y 2" G- 1 1/2" G 2 1/2" G GAS METER BY UTILITY COMPANY (950 MBH) 77 ENL ' GED MECHANICAL ROOM PLA"T y SCALE: 1/4" = 1'-0" 1/2"HW& CW TO TUB/SHOWER ON 1ST AND 2ND FLOORS -5 1-1/2"HW 140F 1/2"HW& CW TO TUB/SHOWER ON 1ST AND 2ND FLOORS 1/2"HW&CW ,TO SINK ON 1ST AND 2ND • FLOORS 1/2"HW& CW TO WATER CLOSET ON 1ST AND 2ND FLOORS 11 1/2"HW&CW TO SINK ON —1ST AND 2ND FLOORS 1/2"HW& CW TO LAVATORY ON 1ST AND 2ND FLOORS TYPICAL FIR•T FLOOR WATER SCALE: 1/4" = 1'-0" 11 3"S STACK FFA 3"S STACK FFA WCO P-5 3"S STACK FFA • 3' S STACK FFA • 1 1/2" S 3"S STACK FFA RECEIVED CITY OF TUKWILA MAY 252017 PERMIT CENTE TYPICAL FIRST FLOOR WASTE & VENT SCALE: 1/4" = 1'-0" B R R Architect of Record: BRR Architecture, Inc. Kansas City i 6700 Antioch Plaza Bentonville Suite 300 Phoenix , Merriam, KS 66204 San Francisco Philadelphia Atlanta Tel: 913-262-9095 Miami , Fax: 913-262-9044 Consultants ACERTUS CONSULTING GROUP, LLC 14817 West 951h Street 0 Lenexa, Kansas 66215 P 913 322 5150 0 F 913 322 5155 www.AcertusGroup.com Copyright Notice This drawing was prepared for use on a speclfic site contemporaneously with Its Issue date and It Is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project Is not authorized and may be contrary to the law. Issues & Revisions NO. DATE DESCRIPTION Project Name WoodSpring Suites Project Address 15643 West Valley Highway Tukwila, WA 98188 • WOODSPRING SUITES' AN EXTENDED STAY HOTEL Project Manager: Checked By: CF Drawn by: RC/MEWED FOR o 't OMPLIANCE ROVED roject NjUN n O -2017 - - 3,000057 f rofesstlTtil Tutr,.atl BUILDING DIVISION EXPIRES: 09/21/17 Sheet Title PLUMBING ENLARGED PLANS Sheet No. P-10 0 BRR Original printed on recycled paper