HomeMy WebLinkAboutPermit PG17-0098 - CASCADE VIEW ELEMENTARY - RAIN WATER LEADERSCASCADE VIEW ELEMENTARY 13601 32ND AVE S PGI 7-0098 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1623049038 13601 32ND AVE S PLUMBING/GAS PIPING PERMIT Project Name: CASCADE VIEW ELEMENTARY Permit Number: PG17-0098 Issue Date: Permit Expires On: 8/18/2017 2/14/2018 Owner: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST, TUKWILA, WA, 98168 Contact Person: Name: JACOB KLEIN Address: Contractor: Name: Address: License No: Lender: Name: Address: 15400 SE 30 PL, BELLEVUE, WA, 98007 HOLMBERG COMPANY 15400 SE 30TH PL, STE 100 , BELLEVUE, WA, 98007 HOLMBC*066ME Phone: (253) 310-8769 Phone: (425) 822-2233 Expiration Date: 9/1/2017 DESCRIPTION OF WORK: INSTALL 2 RAIN WATER LEADERS Valuation of Work: $4,000.00 Water District: 125 Sewer District: NONE,VALLEY VIEW Fees Collected: $171.40 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: Z014 2014 2014 2015 11 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per 't and agree to the conditions attached to this permit. Signature: Print Name:.! r.0 • Date: VA 25/(7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKTN 4 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov Plumbing/6as'Permit No. - 1 00,3 Project No. Date Application Accepted: )-.f '_.( 7 Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: `g -3L` �`~G Ave_ King Co Assessor's Tax No.: 171+00 33 7 Suite Number: /✓A Floor: N/ Tenant Name:' `� ?\ adrei2 L. �SGo� es. New Tenant: El Yes .. No PROPERTY OWNER Name: Address: \sq.°, L �Okh - L - �%-State:l Name: Phone: a S�-'310 - cinit Fax: Email SlrobV.,g 140rowy�. Gom Address: LE6Itc l Sk City: T,*.fr: 1 h State: tvA Zip: Cic‘Ibg' CONTACT PERSON - person .receiving all project communication Name: Address: \sq.°, L �Okh - L - �%-State:l 4 Zip: 9%,? City lwue Phone: a S�-'310 - cinit Fax: Email SlrobV.,g 140rowy�. Gom PLUMBING CONTRACTOR INFORMATION Company Name: ,\41 trop Address: i5tk)� S E 3„.).,--.-)r, City: pe-11G✓"per State: iv Zip:72500) Phone: 'D.€,_ 319, 71 et Fax: Contr Reg No.: 41/1(1 i'%�6MExp Date: GI/,/,i/ Tukwila Business License No.: B6,6 _: 4 7 4 it S Valuation of Project (contractor's bid price): $ "E r flflQ Scope of Work (please provide detailed information): 1SZ��� (...c-1 ler•d,G(s (t A'411i.1) Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Sewer: Page 1 of 2 Indicate type of plumbing fixtures anc ;as piping outlets being installed and the guar- below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) • Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type ' vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES it Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O ER OR AUT ORIZED AGENT: Signatur • Print Name: \:;) 1�1 rr Mailing Address: 154,:::) c. ' . �j F 3.,14.‘ H:Wpplications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: Ci/ f5/) / Day Telephone: c� '5 61 II GV�Pi L—A `'«oc) % City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT QUANTITY PAID $171.40 PG17-0098 Address: 13601 32ND AVE S Apn: 1623049038 $171.40 Credit Card Fee $4.99 Credit Card Fee R000.369.908.00.00 0.00 $4.99 PLUMBING $160.01 PERMIT FEE R000.322.100.00.00 0.00 $94.86 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $32.00 TECHNOLOGY FEE $6.40 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12133 R000.322.900.04.00 0.00 $6.40 $171.40 Date Paid: Tuesday, August 15, 2017 Paid By: JACOB KLEIN Pay Method: CREDIT CARD 07032B Printed: Tuesday, August 15, 2017 10:43 AM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 /r 7-rn9' (206) 431-3670 Project: e ceofirGexkli 1 Type of Inspection. P�f�lAS/V C— f3ML_ Address: j X. / v f%%J 47,0 Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: c<- p4.049/A/c--- Inspector: 'L.049/A/c- Inspector: AC .. Date// -7,-/7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION rkr7- o9b 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pr ject: NC/kW V 6i J. CLLVvi Type �of Inspection: I tll4 - ]rJ PLOWtitiAr&'' Address: / 3oo) 32" /41/6'g Date Called: Special Instructions: • Date Wante 4., /'Z'/ ` mm p m. Reque e : isog Phone No: 4izs-- 6' 7 - , 344s— Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: cf%— R0064N Inspector: cqK Date: —/2-x'7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 17-ao99 PrpJect: C ts64t6 V) LJ £ Type of Inspection: Oaliabkoll< Address: 13601 32,4i. S Date Called: Special instructions: Date W,nt Reque r: Phone No: 425= eq 7 1,15` Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: X23/7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. f'tRMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0098 DATE: 08/15/17 PROJECT NAME: CASCADE VIEW ELEMENTARY SITE ADDRESS: 1360132 AVE S X Original Plan Submittal Response to Correction Letter # Revision # ' before Permit Issued Revision # after Permit Issued DEPARTMENTS: LjldI\idi sio tP Public Works Fire Prevention Structural Planning Division n ❑ Permit Coordinator 111 PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/17/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/14/17 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 HOLMBERG COMPANY Home Espanol Contact Safety & Health Claims & Insurance ciWashington State Department o} Labor & Industries Search L&I Page 1 of 3 A -Z Index Help My L&I Workplace Rights Trades & Licensing HOLMBERG COMPANY Owner or tradesperson Principals WHITE, JEFF K, PRESIDENT BAILOR, WADE WAYNE, VICE PRESIDENT TOBIN, MARK ALLEN, SECRETARY HOLMBERG, A PHER, VICE PRESIDENT (End: 07/30/2015) WHITE, DIANA, SECRETARY (End: 07/30/2015) HOLMBERG, KANDICE K, SECRETARY (End: 07/30/2015) VARRIANO, JON S, TREASURER (End: 07/30/2015) Doing business as HOLMBERG COMPANY WA UBI No. 174 003 387 15400 SE 30TH PL, SUITE 100 BELLEVUE, WA 98007 425-822-2233 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HOLMBC*066ME Effective — expiration 07/05/1994— 09/01/2019 Bond HANOVER INSURANCE COMPANY THE Bond account no. 1959086 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 07/18/2011 09/01/2011 Expiration date Until Canceled Bond history Insurance American Fire & Casualty Co Policy no. BKA55653106 $1,000,000.00 Help us improve https://secure.lni.wa.gov/verify/DetaiLaspx?UBI=174003387&LIC=HOLMBC*066ME&SAW= 8/18/2017 HOLMBERG COMPANY Received by L&I Effective date 07/24/2017 09/01/2013 Expiration date 09/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 15-2-00439-2 Complaint filed by DJ MECHANICAL INC Complaint date 03/13/2015 L&I Tax debts Dismissed Complaint against bond(s) or savings 1959086 Complaint amount $49,186.06 No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 104.069-02 Account is current. Doing business as HOLMBERG CO Estimated workers reported Quarter 2 of Year 2017 "76 to 100 Workers" L&I account contact T1 / JAN BENTLEY (360)902-4652 - Email: STR0235@Ini.wa.gov, Track this contractor Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/17/2013 Inspection no. 316854116 Location 1906 NE 45th Seattle, WA 98105 Inspection results date 04/03/2012 Inspection no. 315796003 Location 1415 5th Avenue Seattle, WA 98101 Violations No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=174003387&LIC=HOLMBC*066ME&SAW= 8/18/2017 HOLMBERG COMPANY Page 3 of 3 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=174003387&LIC=HOLMBC*066ME&SAW= 8/18/2017 0 (E)14x14 (E)12"0 (E)22"0 (E)16x16 (E)12"0 (E)10"0 J IL AI -r-- (E)12 rzzzzo Fes, TT (E)14"0 (E)10x10 (E)10x10 D 0 0 (E)104 0 DN HVAC PARTIAL ATTIC DEMO PLAN -BUILDING A SCALE : 1/8" = 1'-0" 8"0 DN 8x8 DN 10"0 DN 14x14 DN 8x8 1 H 14"0 12"0 TT 11 11 LL 1 1 J 10"0 12x12 DN 10"0 DN 10"0 7 0 0 10"0 DN HVAC PARTIAL ATTIC PLAN -BUILDING A SCALE : 1/8" = 1'-0" AC ESL CLASS VOLUNTEER RM. A101 JANITOR CLST. A117 MEN'S A102 WOMEN'S A103 ELEC. CLST. A116 STAFF LOUNGE i STAFF WORKROOM A105 OFFICE A108 TOILET A109 HEALTH RM. A110 O80 150 OFFICE A113a O 10"0 250 T E)FIT-A06 OB 40 A104 CONF. RM A107 STORAGE A111 3' 0.11 3"RL DN SOFFIT 26x22 UP HP -B01 1E===7 ON ROOF 26 CAFETERIA EXPANSION B113 ©18x8 525 (TYP. OF 7) Oh. ®O10"0 250 RECEPTION A112 ZO250 15"0 SUPPORT STAFF A113 PRINCIPAL OFFICE A114 r L__ J J OFFICE A115 3"RL DN 3"ORL DN SOFFIT 1 -X; 1 12x12 ©10x6 100 20x16 REVISIONS No chang s shat hq made to the scope of wor c tr''ithr?Ii prior approval of TtB0f:ding Division. NOTE: Revisi s will require a new plan submittal and may in ludo a.2 . n , .. n review fees. PROVIDE VOLUME DAMPERS SUITABLE FOR USE IN SOFFIT APPLICATIONS. TYP AS SHOWN. 26x16 VESTIBULE 20x16 BOYS B105 20x12 GIRLS B106 12x12 GENERAL NOTES: VESTIBULE B102 r B101 8107 PPr JILT —QIt IPI D FOR: 4,;sLh3nical GI/Electrical 0 Plumbing Gas Piping City of Tukwila BUILDING D IVISION MULTI-PURPOSE/ CAFETERIA B103 1. COORDINATE LOCATION OF ALL GRILLES, REGISTERS AND OR DIFFUSERS WITH ARCHITECTURAL ELEVATION AND INTERIOR DRAWINGS. PLAN NOTES: CI NEW HEAT PUMP UNIT ON ROOF. SEE CM4.01. O3" RAINLEADERS UP TO COMBINATION ROOF/OVERFLOW DRAIN. REFER TO ARCHITECTURAL FURRING DETAILS FOR ROUTING WITHIN NEW WALL. 3" OVERFLOW NOZZLE, COORDINATE EXACT LOCATION WITH ARCHITECT. SEE DETAIL, SHEET CM9.01. O3" RAINLEADER, EXTEND AND CONNECT TO STORM, SEE CIVIL DRAWINGS FOR EXACT LOCATION. EXISTING THERMOSTAT SHALL REMAIN IN PLACE FOR RE -USE. OREPLACE EXISTING RETURN GRILLE WITH NEW. OAREA OF NEW WORK, SEE PARTIAL DEMO/NEW PLANS THIS SHEET. OWALK-IN BY OTHERS. EXTEND AND CONNECT NEW REFRIGERANT PIPING FROM ROOF MOUNTED CONDENSER. SEE SHEET CM4.01 FOR LOCATION OF NEW UNIT. HVAC FLOOR PLAN - BUILDINGS A & B SCALE : 1/8" = 1'-0" r i LE COPYn/��/ Permit No. i �1 11-0U"l D roDiuda r architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST m ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 0U< ct ZLU Z U) o coo 5 UWJp �' _J 0") O O O _� 11.1 0 CL LLI (n I.L C:1 W �QOQ �(/)X M < Ft3 I- < 0 u) w O 1- 1- -1 1— J wco = CO 00) cn yG � S 0 M 9) 0) ti 0) CO O 1— REVISION DATE Plan review approval i3 subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged. Date: itc(/t7 City of Tukwila BUILDING DIVISION Giiooqg Design: Drawn: Checked: Project No. RSH RSH DMM Issuance BID SET Date: 4/7//2017 Drawing Title HVAC DEMO /NEW FLOOR PLANS - BUILDINGS A & B REVIEWED) D:�.,,w=�,.��na.� RECEIVED CITY OF TUKWILA AUG 15 2017 PERMIT CENTER KEY PLAN E COMFLI/Dtti g Number APPROVED UG 17 ?_017C,xx3 01 City of Tukwila BUILDING DIVISION COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC CM3.01 BLDG A B MECH.DWG UNISTRUT OPTION `04* AI.',�''' 104,,,A„, ' $a (�). �►, ,'� , '/��' SECURE ALL PIPE WITH UNISTRUT CLAMPS T 1-1/2" EXTENSION BLOX OR EQUAL (WHERE NEEDED) FINISHED WALL HANGER ROD ------- � r illl architecture 105 S. Main Seattle, WA t: 206-624-4222 f: 206-624-4226 ar planning interior Street Suite 98104 323 ct design _ ROOFTOP MOUNTED EQUIPMENT / / + % \ , —� (TYPICAL) -�` I METAL WALL SLEEVE FLUSH WITH WALL, AROUND PIPE \9 14. 4/4* o -r.--..---.1--PER - - PACK GAP WITH FIBERGLASS BATT INSULATION ACOUSTICAL CAULK AROUND PIPE•< SPECIFICATIONS 3/4" WAFFLE PAD. SECURE TO Q+ F �' � � `�� ,`° *" I. o '6 43283 ���ISTE0 sIONAL 04/07/17 CURB WITH STAINLESS STEEL .. _ .. FASTENERS. CAULK AT S- - _ - _ _ .. _ . ------------- _ _ _ - _ - _ _ . _ .. _ _ _ - _ - _ - _ - . _ .. _ _ - - _ �- METAL PIPE FINISHED FASTENERSL FINISHED PIPE STRAP OPTION L `� \-� F;_ .% �`�Y' ,. ,' ,�'� .J 11P'' '�� '�� , ,''� �' SECURE ALL PIPE WITH TWO HOLE PIPE STRAPS 1-1 /2" EXTENSION BLOX OR EQUAL (WHERE NEEDED) — — �' ROOF- MOPROOFINGUPSIDESROOF J OF SLEEPER (TYPICAL) //, \ jr: - --�; :.. - STAINLESS STEEL CAP ON SLEEPER; �� �'- L INSULATION AS REQUIRED AND AS SPECIFIED TYPICAL (TYPICAL) RIGID INSULATION INSERT AS FLASH OVER ROOFING (TYPICAL). ROOF DECK PRESSURE TREATED 4 x SECURE WITH STAINLESS STEEL LEVELING SLEEPER BEARING ON FASTENERS ROOF DECK WITH CANT ALL SIDES END VIEW (TYPICAL) (VERIFY EXACT SIZE SIDE VIEW �.. � TIES WEST ENGINEERS TRES WEST ENGINEERS, INC. �' SPECIFIED AND LOCATION WITH EQUIPMENT 3 INSULATED PIPE PENETRATION ESCUTCHEON IF NOT CONCEALED (TYPICAL) - NON -RATED WALL L� '' ` - �' ^�` I o i i� ,�+�''°�� �°`'`► � a �� ROOFTOP BLOX UNIT WITH CUSHIONED BASE OR EQUAL SUPPLIED),,.,.. NOTES: 2 1. GENERAL CONTRACTOR TO PROVIDE SLEEPERS, CANTS, AND ROOFING. 2. MECHANICAL CONTRACTOR TO PROVIDE STAINLESS STEEL CAPS, FASTENERS, AND WAFFLE PADS. ROOF MOUNTED EQUIPMENT W/O CURB "' ��''0 ''/10.4 � ' ,a P T/i BLOX SECURING BRACKET OR 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com . �s� EQUAL. SECURE TO ROOFING ��r WITH STRUCTURAL ADHESIVE ��� �,, ' �/� ��� / —�iiviimm„ FINISHED r W ' n 11 M9.01 SCALE: NONE / M9.01 SCALE: NONE .._4. 4,,,-Aimir . or / PIPE INSULATION AND METAL BIRD SCREEN JACKET / ' / —AO/ / /it / // / / / / / / / / / / / / / / / / / TYPE 25 BEAM CLAMP OR OTHER NOTES: / / / / / , CLAMP SIZED TO GO AROUND RIGID INSERT SIZE TO PROVIDE 1/2" CLEARANCE ALL AROUND SHEET METAL CAN 1. DO NOT PENETRATE';,—'-_=_ ROOFING MATERIAL. 1 ROOFTOP PIPE SUPPORT . U Q SPECIFIED ATTACHMENT THREADED ROD, ATTACH TO 1I r- ::,,,,c_. .c. E�� STRUCTURE; SEE NOTE TRANSVERSE BRACE, SEE NOTE 1 MAY SEE NOTE RE ROD STIFFENER; — PACK WITH FIBERGLASS '_ SLOPE /PIPING; � `�`�` INSULATION ovO rr (/) W Z SIZE AND \ i \I I (E)WOOD CURB (TYPICAL), STANDARD CLEVIS HANGER SIZED TO GO AROUND RIGID-%li INSULATION INSERT, WITH CLEVIS CROSS BRACE N ii 1 i NUT AND WASHER E\.... v ti/ •� QUANTITY AS NOTED ON PLANS RIGID INSULATION INSERT PER SPECIFICATIONS ,, (E)FLASHING (E)FLASHING MEMBRANE PLATE AND SCREW 11 W � J .—I W W < 0 OO I— 1- iwuJzi. M9.01 SCALE: NONE I PIPE SUPPORT SEAM CAULK lialeagill c, EQUIPMENT .� - c, ` c, I 1 i� o ° o o ° EQUIPMENT ANCHORS(MINIMUM 4 Q PER UNIT, 2 ON EACH SIDE) TO BE PROVIDED BY EQUIPMENT/CURB MANUFACTURER ANCHOR CJ D- > W ( N CI I - �- W I•■u� �► _ PIPING INSULATION AS SPECIFIED NOTES: �' RIGID INSULATION INSERT WITH SHIELD AS SPECIFIED 9 0 = 0-.1 lil - M a0 d ■■■.■■■■.■....■■■ -rill i k___ J' I I I I I I I I I I I I I I I I I ___ _L f c --t l a W Ia�a w e a a 1 ". "' W rn 4 ..• EXISTING ROOF -.. FRAMING RISER - CLAMP Z CO 6 O Q —'=t v=Qti J , ♦ /"'1 p t!) 1— �S' 0) L.,,J �,•,l Z 5 4 = M N 4 1. SEISMIC BRACING, RIGID OR CABLE, SIZE, MECHANICAL CONTRACTOR'S SEISMIC ENGINEER, INSULATED PIPE HANGER SPACING, CABLE ANCHORAGE TO BE SPECIFIED BY FOLLOWING SMACNA RESTRAINT MANUAL. D D < U O w OCI) _i I 11� V < 0 c''o . i i2 P-2(1) d 5 ROOF CAP - INSULATED PIPING HP -B01 REVISION DATE M9.01 SCALE: NONE M9.01 SCALE: NONE EQUIPMENT BASE FRAME - NOTES TREATED 2x4 NAILER ATTACH FRAME TO EQUIPMENT ANCHOR -„--EQUIPMENT 11 '. I ANCHOR OVERFLOW ROOF DRAIN PIPE FROM ROOF DRAIN STAINLESS STEEL COUNTER i i 11 FASTEN TO WOOD NAILER ROOF DRAIN (RD) 1. ATE ROOF DRAINS AT LOWE POINTS OF ROOF, AS SHOWN ON PLAN. 2. ALL ROOF FLASHING WORK AND MATERIALS ARE THE RESPONSIBILITY OF THE ROOFING CONTRACTOR. 16„ MINIMUM" FLASHING BY M.C. BUILT UP ROOFING BY OTHERS � 1 1 , ' 11 � � I 1 11 I " III " 1, 1 I � � ' , FACTORY ROOF CURB PROVIDE INSULATION UNDER UNIT; FILL CAVITY Design: RSH Drawn: RSH Checked: DMM Project No. I INSULATION ic���I'1I ,� A`�� 1 I 1 mo._,_ INSULATE PERIMETER OF CURB EXTERIOR WALL FLANGE, SECURE TO WALL, CAULK AND SEAL ALL AROUND INTERIOR WALL 3. ROOFING CONTRACTOR MAY USE AN ALTERNATE WITH RIGID INSULATION MIMI= ROOF FLASHING FLASHING ARRANGEMENT PROVIDED IT HAS BEEN CANT STRIP AND FLASHING BY OTHER! S - OPENING FOR DUCTWORK AS ROOF DECK NEEDED ROOF CONSTRUCTION, SEE ARCHITECTURAL DRAWINGS SUBMITTED TO AND APPROVED 'f11'1 BY THE ARCHITECT. /111111 Issuance BID SET SECURE CURB TO TYPICAL STRUCTURAL SUPPORT MEMBER. (E) CONDITIONS SHALL BE FIELD VERIFIED, �" 0 c,� OVERFLOW ROOF DRAIN NOZZLE WITH SS_ ROOF DECK PROVIDE ADDITIONAL SUPPORT AS REQUIRED BY STRUCTURAL. NOTES: `'� ' ° �� / REVIEWED FOR mu= ate 4/7//2017 BIRDSCREEN CODE COMPLIANC #4 SHEET LEAD BASE, SET APPROVED HEIGHT PER ARCHITECTURAL- ELEVATIONS, SEE ARCH DWGS -mo FINISHED FLOOR IN PLASTIC CEMENT, OR _ _ AUG 17 20 Drawin M SIO g Title ECHAN I CAL 1. SECURE CURB TO ROOF DECK IN ACCORDANCE WITH SEISMIC ENGINEER'S CALCULATIONS AND DESIGN. 2. ATTACH EQUIPMENT TO CURB IN ACCORDANCE WITH SEISMIC ENGINEER'S CALCULATIONS AND DESIGN USING EQUIPMENT ANCHORS SIMILAR TO DETAIL ABOVE. 6 ROOF MOUNTED EQUIPMENT CURB EQUIVALENT. ROOF DRAIN LEADER, City of Tukwila FINISHED GRADE -_ SEE PLANS BUILDING DIV FOR SIZE 1.L IL 7 OVERFLOW DOWNSPOUT NOZZLE 8 RECEIVED CITY OF TUKWILA AUG 15 2017 - PERMIT CENTER ROOF DRAIN ETAI LS Drawing ,����,��9.01 y� g}�y;�,))� "'1i?C�Ci Number --K r�yt�5. fiE �i J M9.01 SCALE: NONE M9.01 SCALE: NONE M9.01 SCALE: NONE ""� �� ��`°i s 1 Yet R���k � i'��a.,°',ffi!�E� COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC CNI 0 r-