Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG17-0106 - BOEING #14-01 - SANITARY WASTE AND VENT PIPING FOR MECHANICAL ROOM
BOEING #14-01 8701 E MARGINAL WAY S PGI 7-0106 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 0007400033 Permit Number: 8701 E MARGINAL WAY S BLDG 14-01 Project Name: BOEING #14-01 Issue Date: Permit Expires On: PG 17-0106 9/5/2017 3/4/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 HOWARD GAMBLE Phone: (425) 204-3937 18802 80 AVE S , KENT, WA, 98032 SHINN MECHANICAL INC 18802 80TH AVE S , KENT, WA, 98032 SHINNMI060QP Phone: (425) 203-9800 Expiration Date: 11/4/2017 DESCRIPTION OF WORK: REMOVE (1) EXISTING LEVEL 4 MECHANICAL ROOM FLOOR DRAIN. MODIFY EXISTING ABOVE GRADE SANITARY WASTE AND VENT PIPING TO ACCOMODATE INSTALLATION OF FOUR (4) NEW LEVEL 4 MECHANICAL ROOM FLOOR DRAINS WITH TRAP PRIMER CONNECTIONS. Valuation of Work: $14,703.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $209.65 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: „Q„SO, �-P Date: t � ' I 7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: /,, Print Name: 0WP- 3) G ,au: Date: Oa( -O5 -20f7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve cinches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS (REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKW1. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. [' 0 ( 010 Project No. Date Application Accepted: Date Application Expires: ,61.x,, ( 1r (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 0007400033 Site Address: 8701 E Marginal Way S Bldg 14-01 Suite Number: 612 Floor: 4 Tenant Name: The Boeing Company PROPERTY OWNER Name: The Boeing Company Address: p0 Box 3707 M/C 20-00 Property Tax Dept City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Howard Gamble Address: 18802 80th Avenue South City: Kent State: WA Zip: 98032 Phone: (425) 204-3937 Fax: (425) 203-9800 Email: howardg@shinnmech.com New Tenant: ❑ Yes ..No PLUMBING CONTRACTOR INFORMATION Company Name: Shinn Mechanical, Inc. Address: 18802 80th Avenue South City: Kent State: WA Zip: 98032 Phone: (425) 203-9800 Fax: (425) 203-9801 Contr Reg No.: SHINNMI060QP Exp Date: 11/04/2017 Tukwila Business License No.: BUS -0992858 Valuation of Project (contractor's bid price): $ 14,703 Scope of Work (please provide detailed information): Remove (1) Existing Level 4 Mechanical Room Floor Drain, Modify Existing Above Grade Sanitary Waste and Vent Piping to Accommodate Installation of four (4) New Level 4 Mechanical Room Floor Drains with Trap Primer Connections Building Use (per Int'l Building Code): Type 11-B Occupancy (per Int'l Building Code): Utility Purveyor: Water: Group F1 Factory H:\ApplicationsWorms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Sewer Page 1 of 2 Indicate type of plumbing fixtures and/ot piping outlets being installed and the quantity „clow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 4 Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) 1 Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 4 Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment 1 Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type I Qty Clothes washer, domestic Food -waste grinder, commercial 4 Wash fountain Water closet industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping 1 Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain 4 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMITAPPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT RIZED AGENT: Signature: Print Name: Howard Gamble Date: 08/29/2017 Day Telephone: (425) 204-3937 Mailing Address: 18802 80th Avenue South Kent WA 98032 H:\Applications\Forms-Applications On Line \201 I Applications\Plumbing Permit Application Revised 8-9-1 I.docs Revised: August 2011 bh City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $209.65 PG17-0106 Address: 8701 E MARGINAL WAY S BLDG 14-01 Apn: 0007400033 $209.65 Credit Card Fee $6.11 Credit Card Fee R000.369.908.00.00 0.00 $6.11 PLUMBING $195.71 PERMIT FEE R000.322.100.00.00 0.00 $123.42 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $39.14 TECHNOLOGY FEE $7.83 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12210 R000.322.900.04.00 0.00 $7.83 $209.65 Date Paid: Monday, August 28, 2017 Paid By: HOWARD GAMBLE Pay Method: CREDIT CARD 07868G Printed: Monday, August 28, 2017 1:21 PM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Wiiil /41/ "0 / Type of Inspection: N'AL Address: 20p 6.-/1,4>Aikc.1 Date Called: Special Instructions: ('-, . /1-/—°/? Date Want ) 0 Requester: mby Phone No: 15-5—S37/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: "ti • REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ProAjct: 1A.,e1A/6- /1) —0 l T e of Inspection: 4- -IN/ ic.4iwl ai I:16- A dress: ?oDC17'I ).MA60 Date Called: Special Instructions: Date Wante0 4 a.m. Requester: Phone No: [IR' Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: 943 17 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 300-2 11D.1'Trap Primer Va s �' "�� "f)' '' r ' r 221 PRIMER VALVES f � 221 1.i P-2 P/ Series Trap,PrimerValve � E J • [12.1=500 AND-P2500PRESSURE-DROVACTIVATED " SUBMITTAL TRAP PRIMER The P1-500 and P2-500 are adjustable to the static line pressure by use of the adjusting screw. System operating range is 20 psi minimum to 80 psi (138 to 552 kpa) maximum. The valve requires a 10 psi (70 kpa) pressure drop across the valve to activate and will deliver a metered amount of water to the floor drain. The trap Primer is to be connected to a cold water supply only. Constructed of 360 brass, EPDM E70 O -rings, Dow #7 Silicone, #60 stainless steel mesh screen, stainless steel adjustment screw. Model P1-500 will prime 1-4 floor drains using our patented DU -U Distribution unit. Model P2-500 will prime 1-2 floor drains using our patented DU -U Distribution unit. REVIEWED FOR CODE COMPLIANCE APPROVED PROJECT SUBMITTAL AUG 3 0 2011 Project' Contractor: 1 BUILDING DIVISION Engineer Date Submitted' Prepared By: Qity of Tukwila www.pppinc.net !ALF, Model P-1 Model P-2 1 1/8" (29mm) FLOOR DRAIN TRAP PRIMER VALVE MODELS: P1-500 & P2-500 PG1'7,4)Wif9 RECEIVED CITY OF TUKWILA AUG 282017 PERMIT CENTER PATENT NO. 5,263,508 •, , • TRAP VALVES 221300-2:11D.1 Trap Primer Valves P-1 & P-2 Trap.Prirner Valve INSTALLATION REQUIREMENTS This valve is designed to be installed on 1/2" to 1 1/2" cold water line, feeding a flush valve or other open and closing valve supply line that is frequently used. Trap Primer valve makeup line to floor drain is recommended to be a minimum of 12" off the finished floor before a 90° elbow can be installed. The furthest recommended distance of makeup line is 20' to the floor drain. Trap primer make up line must have continuous slope to the floor drain (consult local code requirements). Install with a shut off valve for servicing on the inlet side and a union connection on the outlet side. The valve must be installed level. If using the distribution unit the clear plastic cover must be used. Do not subject the valve to rough in pressure test. RECOMMENDED INSTAU.ATION DRAWING 1 1-1/2" BRANCH UNE RECOMMENDED INSTALLATION DRAWING 2 c T.P. 3/4" t/2" URINAL LAV 1 -1/2" BRANCH UNE 3" MAIN RISER M. SPRY Ma LIP LW J�ndwj 1rii , inc_ FLOOR DRAIN TRAP PRIMER DISTRIBUTION CHART Primer Model # of Drains Distribution Units P2-500 1 N/A P2-500 2 DU-4/DU-U P1-500 3 DU-4/DU-U 1P1-500 4 DU-4/IDU-U Multiple Drain Installation Single Drain Installation Inlet Service Valve 1/2" NPT 12 mm P1-500 Primer Valve P2-500 -40— Primer Valve E E 0 1/2" FNPT 12 mm E 0 V.B. Ports Union Connection Distribution Unit DU -U Drain Supply Line Minimum 1/2" Copper Precision Plumbing Products Division of JL Industries, Inc. 802 SE 199th Ave Portland, Oregon 97233 T (503) 256-4010 F (503) 253-8165 www.pppinc.net Minimum 1/2"copper floor drain trap make-up water line. Not supplied. �!A r4/ r. 2' F i TRAP , PRIMER VALVES 221300-2.11 D.1 'Trap Primer Valves Precision Plumbing Products "Specify with Confidence Install with Pride'' Installation Instructions INSTALLATION P1-500 & P2-500 TRAP PRIMER VALVES --1 1.) 2.) 3.) Flush line prior to installation. Use ribbon pipe seal tape - ONLY. A) Install valve plumb using caution to not over tighten. Tightening to more than 55ft.lbs. can damage valve B) and void the warranty. Do not wrench on hex. 4.) Effective operating range 20 to 80 PSIG (138 to 552 ) kpa). Min. discharge rate for P1-500, is 71.25 ml/m at C 20 PSIG. Min. discharge rate for P2-500 is 56.25 ml/m at 20 PSIG. 5.) Do not subject Trap Primer Valve to pressure in excess of 125 PSI. 6.) Failure to follow these instructions will make the product warranty null and void. \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\y ision Products of Portland, Oregon (USA) outmanufactured Plumbing oducts to be free from defects and wortcman- ship under use and e. The sole and exdusive y d express wanantyldfor our manufactured pourur sole obligation at do not under this nform to mited as limited nd ex- press e part or product during the ree ye afteinstallation. stallans warranty des any parts or prodoriginal areor installed where PH levels, chemical conditions or electrolysis pre- maturely degrade the product We specifically disclaim any warran- ties or responsibility for defects due to quality, material, dimensional tolerances or quality control of any fitting or other third party supplied parts or components. EXCLUSIONS OF ALL OTHER WARRAN- TIES INCLUDING IMPLIED WARRANTIES: All other warranties, induding the implied warranties of MERCHANTABILITY and fitness for a pa purpose, are EXCLUDED from this transadion and shall not apply to goods sold by us. The above warranties are in lieu of all other warranties and representations, express or implied, and all other obligations or liabilities on our part. We shall not be liable for consequential damages, loss of profit, interruption of business or any other special, incidental, or punitive damages suffered or sus- tained by Customer. Any part or products being retumed under this warranty must have prior authorization by us. Any part or product re- ceived by us without a return of goods authorization will be retumed j to the shipper. All returned merchandise must be prepaid by ship- per. Our personnel, induding salespeople, as well as independent distributors and sales agents may have made oral statements about our products. Those statements are not warranties by us and should not be relied on by the buyer/customer/user. If you use this product you are agreeing to this warranty contract between us. This writing constitutes the final expression of the parties and is the complete and exdusive statement of that contract for warranties. Rev 05/09 D) E) F) G) H) CAUTION www.pppinc.net To adjust: Tum adjusting screw counter clock- wise until a steady flow is produced. Tum adjusting screw clockwise until dripping just stops. Primer is now set to line pressure. Cycle primer at least (5) times to insure proper activity. The Trap Primer must be installed on a cold fresh water line of 1 1/2" dia. or less. Must be installed near a fixture that creates a minimum of 10 PSIG pressure drop. Do not install on water heater line due to in- sufficient pressure drop. Do not subject Trap Primer Valve to pressure in excess of 125 psi. All drain supply lines must be clear to assure proper discharge to trap. Failure to do so could result in water discharge through air gap port Use debris loop to ensure foreign matter from entering directly into the primer. Inlet Service Valve .4---- P2-500 Primer Valve Union Connection Inlet Valve �> P1-500 Primer Valve Optional DU -U Union Connections Drain Supply line minimum 1/2" Copper. Not Supplied. The Priming valve must have min. elevation of 12" (305mm) above the finished floor. Allow 1 foot of elevation for every 20 feet of distance run for floor drain make-up line. jndostriaa. ioc. Precision Plumbing Products Division of JL Industries, Inc. 802 SE 199th Ave Portland, Oregon 97233 T (503) 256-4010 F (503) 253-8165 www.pppinc.net E Its ' 1 arrrnrED-oma, MI-TPV-02 Rev 02/11 !! Floor' Drain, Trap'Primer'Distribution Systems FLOOR -DRAIN TRAP -PRIMER,.:.~ FRESH WATER DISTRIBUTION SYSTEMS UNIVERSAL DISTRIBUTION UNIT DU -U is a PVC body distribution unit with 4 - 3/8" FPT discharge fittings and 1/2" male NPT composite inlet. DU -4 is a copper body distribution unit with 4 - 3/8" FPT brass discharge fittings and 1/2" male NPT composite inlet. All distribution units come with two plugs. 4 1/2" DU -U DU -U-500 DU -U-625 Just the facts: The Trap Priming Distribution Systems are patented designs that incorporate both copper and PVC materials. These designs give the installer a simple and positive means to prime multiple floor drains using only one Precision Plumbing Trap Priming Valve. It is our recommendation that the distribution unit be mounted level. The fresh water supply line, running from the distribution unit to the trap, must be a minimum of 1/2" O.D. copper tube. Model #: PROJECT SUBMITTAL Project: Contractor: Engineer: Date Submitted: Prepared By: Fig. 1 www.pppinc.net A 0 3 3 co CL CD 0. m iv O. n O cQ c m 0 Parts not supplied For installation dimension see table below. INSTALLATION DIMENSION (see fig. 1) PRIMER MODEL: DU -4 DU -4-500/625 DU -U DU -U-500/625 CII 12 1/2" 12 3/4" 12" 12 1/4" P2 12 1/2" 12 3/4" 12" 13 1/4" PRIME -RITE 12 1/2" 12 3/4" 12" 13 1/4" OREGON #1 14 1/2" 14 3/4" 13 1/2" 14 3/4" CPO -500 14 1/2" 14 3/4" 13 1/2" 14 3/4" SP -500 12" 12 3/4" 11 1/2" 12 3/4" MP -500 12" 12 3/4" 11 1/2" 12 3/4" MPB-500 17 3/4" 19" 17 1/2" 18 3/4" PRO1-500 6 1/2" 7 3/4" 6 1/8" 7 1/4 Jjndaistri9s, inc_ Precision Plumbing Products Division of JL Industries, Inc. 802 SE 199th Avenue Portland, Oregon 97233 T (503) 256-4010 F (503) 253-8165 www.pppinc.net Wife in Pe U0R. sotiseaatJabs U.S. Patent No. 3,776,269.6,325,091 TRAP PRIMERNAL'VES 221300-2.11D.2 Trap Primer,Valve Distribution Units i Installation' Instructions .r J� 1.,>• liifl .24 11:4" Precision Plumbing Products "Specify with Confidence - Install with Pride'° INSTALLATION DU -U and DU -4 WATER DISTRIBUTION UNITS 4 1.) Install the drain fittings provided (plug & compression) into the drain outlet. 2.) Install DU -Unit between rigid supply/ primer and rigid drain lines, as shown. www.pppinc.net DU -Unit may be directly threaded into prim- er outlet, hand tighten. Although our DU -Unit will distribute water off plumb, it is recommended that the DU be installed plumb for optimum distribution. WARNING: THIS IS A GRAVITY DRAIN UNIT, THIS IS NOT INTENDED TO BE PRESSURIZED. Precision• prod cls to bing Products of Portland, Oregon (USA) be free from defects and workmanship undermanufac- turedrrants our normal use anser- vice. The sole and exclusive remedy for our manufactured products that do not con- form to this limited and express warranty and our sole andexpress parts s warranty Ins to replace the defective part r product during the ree year areludes any parts or products that cmodified or improperly installed or sstallation. This tall d whnty ere PH levels, chemical conditions electrolysisor prematurely specifically war- ranties tieorressi r defects due to quamaterial, dimensional tolerances control r�fttn partyoneer EX- CLUSIONS A WARRANTIES WARRAN- TIES: All othertherrwarrantsndud timplied warranties of MERCHANTABILITY and fitness for a particular purpose, are EXCLUDED from this transaction and shall not apply to s d by us. e ve warranties are in lieu of ll other warranties and representadtions lexp express or�implied, and all other obligations or liabilities on our part. e l not be liable r consequential damages, loss of profit, ption of bu Customer. s or lnAn other art oraapooduds being, incidental, or returnedpunitive undeages this s warranty must have bygoodseceived by us without a retum of authorization will be retumed to thprior authorization by us. Any part or e product pper. r. All a umd merchandise must be prepaid by r. Our rsonnel, induding distributors and sales agents may have made oral statements is about our productsple, as well as . tements are not warranties by us and should not between Those us customer/user. syou writinceconstitutes the final are re agreeing be the warranty icontract athe complete and exclusive statement of that contract for warranties. partiesRev 05/09 i \so Supply Trap Primer Valve Inlet DU -U Drain Outlet J dwatriaa. mr_ Precision Plumbing Products Division of JL Industries, Inc. 802 SE 199th Ave Portland, Oregon 97233 T (503) 256-4010 F (503) 253-8165 www.pppinc.net MI -DU -01 Rev 03/06 PERMIT COORD COPY .. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0106 DATE: 08/28/17 PROJECT NAME: BOEING #14-01 SITE ADDRESS: 8701 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division 4,16 IA *All Public Works Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 08/29/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/26/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 SHINN MECHANICAL INC ''®"' Washington State Department of Via Labor & Industries Page 1 of 3 Home Espanol Contact Search L&I A -Z Index Safety & Health Claims & Insurance Workplace Rights SHINN MECHANICAL INC Owner or tradesperson Principals SHINN, MICHAEL D, PRESIDENT GILMORE, DONALD J, VICE PRESIDENT MOE, JENNIFER T, SECRETARY Doing business as SHINN MECHANICAL INC WA UBI No. 601 585 839 18802 80 TH AVE SOUTH KENT, WA 98032 425-203-9800 KING County Business type Corporation Governing persons MICHAEL DOUGLAS SHINN DONALD J GILMORE; JENNIFER T MOE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. SHINNMI060QP Effective — expiration 11/17/1994-11/04/2017 Bond HARTFORD CAS INS CO Bond account no. 52BSBDN1736 $12,000.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601585839&LIC=SHINNMI060QP&SAW= 9/5/2017 SHINN MECHANICAL INC Received by L&I Effective date 11/03/2005 11/17/2005 Expiration date Until Canceled Insurance Phoenix Insurance Company, The $1,000,000.00 Policy no. DTCO2F32448APHX15 Received by L&I Effective date 10/11/2016 11/21/2015 Expiration date 11/21/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Page 2 of 3 No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 231,976-00 Account is current. Doing business as SHINN MECHANICAL INC Estimated workers reported Quarter 2 of Year 2017 "51 to 75 Workers" L&I account contact T2 / SUSAN BETTS (360)902-4828 - Email: BETT235@Ini.wa.gov Track this contractor' i( Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. NelgJAsiCLi (rove https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601585839&LIC=SHINNMI060QP&SAW= 9/5/2017 2'V 4"V 62 64 7.2 8.2 8.4 c 9.2 REVISION CAD CONVERSION BY CADDNW 6"A DN APPROVED DATE SYM REVISION BY APPROVED PLUNBI\G PLA\ SCALE: 1/8"=1'-0" DATE 04.24.98 UPGRADE HIGH—BAY HVAC 28805 CEI MS 01.06.17 g)LAIMPEZAW® ACOFFMANINEENG 1801 Fifth Avenue, Suite 9001 Seattle, WA 98101 ph 206.623.07171 fax 206.624.3775 coffman.com LASTING «eetlety 1 results 1 relelbnWpe ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY McCLUNG CHECKED ENGINEER 6"A DN LEGE\D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTL: Revisions will require a new plan submittal and may include additional plan review fees. GE\ERAL \OTES FELE COPY Peit No. VG fizz D(oSo Plan review approval is subject to errors and omi Approval of construction documents does not a the violation of any or ordinance. of approved Field Copy and conditions is ackno B Date: 01 -OS- 201/ City of Tukwila SUILDING DIVISION REFERS\CE DRAWI rut SAT \GS AIR FILTER, BOTTOM ® 48"AFF SEE DETAIL 4M110 M504 ( REVIEWED FOR CODE COMPLIANCE APPROVED AUG 302011 City of Tukwila BUILDING DIVISION !SEPARATE PERMIT PaTIL RED FOR: "cChanica) fE'ectricat 0 Plumbing . G ias Piping City of Tukwila k.j iLD!l'4G DIVISION CONSTRUCTION NOTES �- REMOVE EXISTING FLOOR DRAIN. REMOVE EXISTING DRAIN PIPING. REMOVE EXISTING FLOOR MOUNTING PIPE SUPPORT. RECEIVED CITY OF TUKWILA AUG 2 8 2017 PERMIT CENTER REMOVAL 100% SUBMITTAL ISSUE FOR CONSTRUCTION CHECKED APPROVED SUBTITLE TITLE MECHANICAL MASTER PLUMBING PLAN UPGRADE HIGH -BAY HVAC BUILDING 14-001 COL. B -C/6-9.2 THOMPSON, WA 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" CURRENT REVISION 28805 SYMBOL A DATE 01.06.17 SHEET 4M110AR JOB NO. COMP NO. DWG NO. 14-001-4M110AR KluRnan• 11 /7R /in 4"RWL DN 1/2"TP DN 1/2"CW DN TO TPV �ltr bik / 2"V DN _ VA MATCH LINE rn rn 4t 41t. C) XI Z -o - RWL Ivl _ TRAP PRIMER VALVE (TPV) STORAGE 2 FFD -1 (P 45C 2"V4"VTR I UP ELECTRICAL AREA —� L STAIR ! 1 I i 4000 IIHHI IIIIIIIE I COMPUTER COMPUTER RWL ELEVATOR (4004A) IG- RWL 40(?7 qn LOBBY ELEV� eR #1 4006 1 I►�I4002I40034004 1 1/2"400 4"RWL UP TO , WL UP TOROOF AHU4"RWL UP TO I-4 DRAINii MECHAN ICA • i30ROOF DRAIN ROOF DRAIN_tx z� PREHEAT COIL I 1 " ( 4004 x ( 4001) I Lx -x -z -x -x -x -x x z x- z x -x z-x-x-x-xxx-x x-x-xJ 2 FFD -1 - x -x -x -x -x -z x x x x x 1/2" 6" ,, x ( 4007 ) - -C) OOLING COIL �x—x—x—x-i ,-x- _x—z X x— x—x-1 OPEN MEZZANINE 1 1/2"ID .`:. /�'' 1 1/2" 2iD I I I 4005 // 1 1 1 I6" " I I 3 ---f04_ 6" „ 1140...viri •a-- CW A` )N tL ©''tm% • • . �r, . " --..�- CW --� , L I 2'VTR -1 a I „ i Iii CW -0--T Ar ACK) _ x x x x x x x x x x-4r-x-x-x-x-x-x-x-r—x—x—x— }� ---J----- • JP Fel 1 R \ 3ii CW DN 2"V DN 1/2''A 4"CW DN LI REVISION CAD CONVERSION BY CADDNW 6"A DN APPROVED DATE SYM REVISION BY APPROVED PLUNBI\G PLA\ SCALE: 1/8"=1'-0" DATE 04.24.98 UPGRADE HIGH—BAY HVAC 28805 CEI MS 01.06.17 g)LAIMPEZAW® ACOFFMANINEENG 1801 Fifth Avenue, Suite 9001 Seattle, WA 98101 ph 206.623.07171 fax 206.624.3775 coffman.com LASTING «eetlety 1 results 1 relelbnWpe ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY McCLUNG CHECKED ENGINEER 6"A DN LEGE\D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTL: Revisions will require a new plan submittal and may include additional plan review fees. GE\ERAL \OTES FELE COPY Peit No. VG fizz D(oSo Plan review approval is subject to errors and omi Approval of construction documents does not a the violation of any or ordinance. of approved Field Copy and conditions is ackno B Date: 01 -OS- 201/ City of Tukwila SUILDING DIVISION REFERS\CE DRAWI rut SAT \GS AIR FILTER, BOTTOM ® 48"AFF SEE DETAIL 4M110 M504 ( REVIEWED FOR CODE COMPLIANCE APPROVED AUG 302011 City of Tukwila BUILDING DIVISION !SEPARATE PERMIT PaTIL RED FOR: "cChanica) fE'ectricat 0 Plumbing . G ias Piping City of Tukwila k.j iLD!l'4G DIVISION CONSTRUCTION NOTES �- REMOVE EXISTING FLOOR DRAIN. REMOVE EXISTING DRAIN PIPING. REMOVE EXISTING FLOOR MOUNTING PIPE SUPPORT. RECEIVED CITY OF TUKWILA AUG 2 8 2017 PERMIT CENTER REMOVAL 100% SUBMITTAL ISSUE FOR CONSTRUCTION CHECKED APPROVED SUBTITLE TITLE MECHANICAL MASTER PLUMBING PLAN UPGRADE HIGH -BAY HVAC BUILDING 14-001 COL. B -C/6-9.2 THOMPSON, WA 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" CURRENT REVISION 28805 SYMBOL A DATE 01.06.17 SHEET 4M110AR JOB NO. COMP NO. DWG NO. 14-001-4M110AR KluRnan• 11 /7R /in SYM 3/4"CW U 4"V UP&DN �.4 7.2 8.2 84 9.2 ,__, STAIR #1 ____ FOR ENLARGED PLAN DETAILS (-2 1/2"TP UP f0 TPV e.- 2"V UP 3M 110A 3M4503M 110A 3M450 31B6 �/ J L OP OFF 4"RWL UP & DN N CE WALL MTD ( 301 ELEVATO • I N D111 �, DATA 2„ 1LOBBY / -� irm 3 g8 31B7 - SA, 2„SAN UP TO - - ► 2-- G MENS o `p + co m2SA INFERENCE OOM 33B6 FFD -1 1 2” C c' 3269 2» 2/'V .., WOMENS JANITOR 2" 1/2"HW BUS - OPEN 34B8 31B91 DEV OFFICE WORK 1/2"CW 32B7 3168 a ROOM �J 2"V UP 35;;� /� 3467 �_Ai 2"SAN UP TO N D 1 FFD-1sal 1 W a- RIVACY P-7\ OFFICE PRIVACY 3668 '- r 35B7 '-- 3266 VES ULE '� COFFEE 39 9 ROOM 2"SAN UP TO FD (4 TYP.) ` N � 35B8 2» CW -6.''A UP&DN 3"CW UP & DNI 2"SAN DN 1 /2"TP TO TRAP PRIMER VALVE (4 TYP.) DRAWING#: MR#: 2" FD .v,w 2"FD-!-hc (-< __NV TP 4"CW '%---1/2." EN - -fa" -rPV DU Goee Dolt- TIP. 2"FD-I � u do -7._ W • • • • �i �� i - wee DIZ{ LL - NP. � \ �i''',!' 1 { f/z'TP wRS7E V€N T Pt'(NC6 QIRot2Arn FAB ORDER REVISION ORDER DATE: CONTACT: # PRIMER BLACK PRIMER GRAY SPECIAL INSTRUCTIONS: -2,.v JOB#: �! -=CE. 4"v - PHASE CODE: SET -2u DATE REQUIRED: A B CAD CONVERSION P-8 PHASE 2 - IFC PACKAGE 1 RECORD DRAWING UPGRADE HIGH -BAY HVAC 28805 BY CADDNW CEI DLR GROUP CEI APPROVED DATE SYM REVISION BY APPROVED PLU v13I\G PLA\ SCALE: 1 /8"=1'-0" DATE 04.22.98 MS JH MS 02.06.11 07.08.11 01.06.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY 4"CW UP & DN ACOFFMANNGINE EAS 1601 Fifth Avenue, Suite 9001 Seattle, WA 98101 ph 206.623.07171 fax 206.624.3773 coffman.com LASTING creativity 1 results 1 relat«flHw REVIEWED FOR CODE COMPLIANCE APPROVED AUG 3 0 2017 • City of Tukwila BUILDING DIVISION LEGE\D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. GE\RAL \ OTES REFERENCE DRAWI \GS CO\STUCTIO\ \OTES PROVIDE AND INSTALL NEW 2" SANITARY PIPING. ©- PROVIDE AND INSTALL NEW 2" VENT PIPING. CONNECT EXISTING 2" SANITARY PIPING TO NEW FLOOR DRAIN. 4 PROVIDE AND INSTALL TRAP PRIMER PIPING TO NEW FLOOR DRAINS. 17% 3M110A.Of 3M110B 100% SUBMITTAL ISSUE FOR CONSTRUCTION DATE SUBTITLE DEPT. DATE CHECKED APPROVED A P OVED TITLE PLUMBING PLAN UPGRADE HIGH -BAY HVAC BUILDING 14-001 MECHANICAL MASTER COL. B -C/6-9.2 THOMPSON, WA 3M111A 3M111B RECEIVED CITY OF TUKWILA AUG 28 2017 PERMIT CENTER CURRENT REVISION 28805 SYMBOL 8 DATE SHEET 3M110A 01.06.17 JOB NO. COMP NO. DWG NO. 14-001-3M 110A 11. 7 /11 /9n> > 9.nn•9A au 62 7 7 8 8.4 REVISION �6"A DN - TRAP PRIMER VALVE (TPV) BY APPROVED DATE SYM REVISION APPROVED PLUIv3I\G PLA\ SCALE: 1/8"=1'-0" DATE CAD CONVERSION CADDNW 04.24.98 UPGRADE HIGH—BAY HVAC 28805 CEI MS 01.06.17 BOE/A/G® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN McCLUNG CHECKEb `ENGINEER CHECKED 6"A DN ACOFFMANNGINE EAS 1601 Fifth Avenue, Suite 900 I Seattle, WA 98101 ph 208.823.07171 fax 208.824.3775 coffman.com LASTING creativity 1 results 1 relationships LEGE\D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. GE\RAL \OTES REFERE\CE DRAWI\GS AIR FILTER, BOTTOM 48'AFF SEE DETAIL 4M110 M504 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 3G 2017 City of Tukwila BUILDING DIVISION CO\STRUCTIOF\ \OTES PROVIDE AND INSTALL NEW FLOOR DRAIN. PROVIDE AND INSTALL NEW VENT PIPING. PROVIDE AND INSTALL NEW TRAP PRIMER VALVE & PIPING. SEE DETAIL 5/M505. RECEIVED CITY OF TUKWILA AUG 2 8 2017 PERMIT CENTER 100% SUBMITTAL ISSUE FOR CONSTRUCTION DATE SUBTITLE PLUMBING PLAN 1 0 n 4M111A 4M1116 T.,-( 4"RWL DN ,441110.AW//: 4M1108 1/2"TP DN 1 /2"CW DN \ TO TPV .40,,2"V DN l 1 111 MATCH LINE c".. 0" 4:.• o73 Z '° 10'''' lour TRAP PRIMER VALVE (TPV) STORAGE » 2"FFD-1 ;L�� �.I 2"V ---/-%---3)\--- UP ELECTRICAL I ARRA I "COMPUTER —J STAIR #1 4000 RWL I COMPUTER RWL ELEVATOR 40 4A - IG. 'io , Y RWL �':' LOBBY 4006 ELEVa'OR #1 4002 • I 4003 4004 1 1/2"- o8n i 4"RWL UP TO ROOF DRAIN I % 4"RWL UP TOI I I ROOF DRAIN AHU 4000 4"RWL UP TO ROOF DRAIN x I 30 11111111 X I PREHEAT COIL I I I 1 ( 4004 4001 1 OPEN MEZZANINE L_x-x-_x-X-x-x=X X X x= •- .- x-x-><-x-x-X-.-x x X-x-X-� 2"FFD-1 - X -,-,-X- a 2 „ FD ECHANI1_1 ROOM ,. Q - ( 4007 ) -X—x—x—a—=—X—X—X—x- 6" A 4006) C�� 4002 4003) - -COOLING COIL K X -X -x -x x= -X-- 1 1 ( � I I I I I x (�,,� 1 1/2"ID 4001 1 1/2" 1 CFD 2„ FD >E2 2"FD 2"V DN / 2„ " 1/2" g» /1 4005 (_63" A CW I..I —424 ISI CW—.0-- ArI t ! .x I ,! �r a -42- CW R-- �X-x-X-xJ LX-x-x—x—,—x-�,-x_,-X-X-X_,-X—,—x_x_x_ 2'VTR-� �= „ ,. IAr • 4"V UP © 3"CW DN 2"V DN 1 /2 A 4"CW DN REVISION �6"A DN - TRAP PRIMER VALVE (TPV) BY APPROVED DATE SYM REVISION APPROVED PLUIv3I\G PLA\ SCALE: 1/8"=1'-0" DATE CAD CONVERSION CADDNW 04.24.98 UPGRADE HIGH—BAY HVAC 28805 CEI MS 01.06.17 BOE/A/G® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN McCLUNG CHECKEb `ENGINEER CHECKED 6"A DN ACOFFMANNGINE EAS 1601 Fifth Avenue, Suite 900 I Seattle, WA 98101 ph 208.823.07171 fax 208.824.3775 coffman.com LASTING creativity 1 results 1 relationships LEGE\D 1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS SEE SHEETS M1a, M1b AND M1c. GE\RAL \OTES REFERE\CE DRAWI\GS AIR FILTER, BOTTOM 48'AFF SEE DETAIL 4M110 M504 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 3G 2017 City of Tukwila BUILDING DIVISION CO\STRUCTIOF\ \OTES PROVIDE AND INSTALL NEW FLOOR DRAIN. PROVIDE AND INSTALL NEW VENT PIPING. PROVIDE AND INSTALL NEW TRAP PRIMER VALVE & PIPING. SEE DETAIL 5/M505. RECEIVED CITY OF TUKWILA AUG 2 8 2017 PERMIT CENTER 100% SUBMITTAL ISSUE FOR CONSTRUCTION DATE SUBTITLE PLUMBING PLAN 1 0 8' 4' 0 4' 8' 16' SCALE: 1/8"=1' -0" CURRENT REVISION 28805 SYMBOL A DATE 01.06.17 A PROVED APPROVED TITLE MECHANICAL MASTER UPGRADE HIGH -BAY HVAC BUILDING 14-001 COL. B -C/6-9.2 THOMPSON, WA SHEET 4M110A JOB NO. COMP NO. DWG NO. 14-001-4M 110A Lt r MvRnRn• 19 /7R /1 n n 4M111A 4M1116 T.,-( ,441110.AW//: 4M1108 l 1 8' 4' 0 4' 8' 16' SCALE: 1/8"=1' -0" CURRENT REVISION 28805 SYMBOL A DATE 01.06.17 A PROVED APPROVED TITLE MECHANICAL MASTER UPGRADE HIGH -BAY HVAC BUILDING 14-001 COL. B -C/6-9.2 THOMPSON, WA SHEET 4M110A JOB NO. COMP NO. DWG NO. 14-001-4M 110A Lt r MvRnRn• 19 /7R /1 n