Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG17-0142 - CLOUD NINE CREAMERY - PLUMBING, GREASE TRAP
CLOUD NINE CREAMERY 191 SOUTHCENTER MALL PGI 7-0142 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 9202470130 191 SOUTHCENTER MALL Project Name: CLOUD NINE CREAMERY Permit Number: PG17-0142 Issue Date: 11/15/2017 Permit Expires On: 5/14/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 ANDREW HAGEE 6617 S 193RD PL, SUITE P-102 , KENT, WA, 98032 ALLY PLUMBING INC 6617 S 193RD PL STE P 102, KENT, WA, 98032 ALLYPP1850PH Phone: (206) 992-6892 Phone: (206) 883-5979 Expiration Date: 10/8/2019 DESCRIPTION OF WORK: NEW PLUMBING FOR ICE CREAM SHOP. INCLUDES INSTALLATION OF A GREASE TRAP INTERCEPTOR. Valuation of Work: $18,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $708.29 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: £1A1fJv) Date: 1! I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit a d agree to the conditions attached to this permit. Signature: Print Name: eeet This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: 11/I S- 717 PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 15: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 16: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 17: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 18: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 19: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 20: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 21: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 22: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 23: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 24: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 25: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 26: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 27: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 28: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 29: The grease interceptor shall be installed per manufacturer's specifications. 30: The grease interceptor shall be installed per manufacturer's specifications. 31: The grease trap/interceptor shall be maintained per WESTFIELD Southcenter Grease Trap Maintenance Program, unless otherwise directed by the Westfield Mall Management. Description of maintenance program is attached as part of this permit. 32: The grease trap/interceptor shall be maintained per WESTFIELD Southcenter Grease Trap Maintenance Program, unless otherwise directed by the Westfield Mall Management. Description of maintenance program is attached as part of this permit. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKW. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov PON Plumbing/Gas Permit No. P L. 11' 0 i r Project No. t2t1#vt,o Date Application Accepted: 11' 1,• 11 Date Application Expires: 11 • ` ' l0 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: \ v� t Soutkv\c'eA4Qr M!t\Suite Number: -700 Floor: New Tenant: Yes O.. No Tenant Name: (I()I tiv1tZ- (<' TPD,vv e(- 6 PROPERTY OWNER Name: A,,v7,0 viov 2 Name: AVi(ve1.0 /,ila„ City: kQm,kState: vi A Zip: at`?,)?2 Address: 66)7 ' 4rc\C t .,0d, City: C(Lvvk State: wA- Zip: 100,3a. CONTACT PERSON — person receiving all project communication Name: A,,v7,0 viov 2 Address: 66 7 5 m 2.? A pi ity,� -14, City: kQm,kState: vi A Zip: at`?,)?2 Phone: ( ) evos 68 Fax: Email: 6AN\r u.) 6-\\V\P1U1441Vln, 47"4 PLUMBING CONTRACTOR INFORMATION Company Name: (� 7 pillltd t' 1(,1 V�6 l '� /'/ ddress: 17, ✓� )� 3 riA v, < < i- f - J e, I City: key*— State: w11 Zip: i fQ T' Phone: ( x6 ) 1.7A. 6.,O.,7 Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 'le)/ a -)O Scope of Work (please provide detailed information): /1/aw .12lwvvlb vi -F - iGc (r ' - A iib y Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: H \Applications\Forms-Applications On Line \2.011 Applications\Plumbing Permit Application Revised K-9-11.docx Revised: August 2011 bh Page 1 of 2 Indic fettypte ofpluptbi fg fixtures and/o4_ , piping outlets being installed and the quantit, _,low: a + rF • Fixture Type ; : Qty Bathtub or ctl lbination bath/shower\"'t'` 1 `" Dishwasher, domestic with independent drain 6 6 Shower, single head trap !!�� Sinks $ Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 I Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 6 6 Wash fountain !!�� Lavatory o`- Urinal Water heater and/or vent Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter I Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Clothes washer, domestic Food -waste grinder, commercial 6 6 Wash fountain Water closet .), Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Dental unit, cuspidor Floor drain F ccw- s t.n k 6 6 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN 0 UTHORIZED AGENT: Signature: Print Name: f" rei,t)G�,fc��� Day Telephone: Mailing Address: '"6"(15 of �j 1' S7k G7 19^ City H:Wpplications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-I 1.docx Revised: August 2011 bh Date: Vo 11 doh- 4q --G Q WA- 4fc7 State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $544.84 PG17-0142 Address: 191 SOUTHCENTER MALL Apn: 9202470130 $544.84 Credit Card Fee $15.87 Credit Card Fee R000.369.908.00.00 0.00 $15.87 PLUMBING $528.97 PERMIT FEE R000.322.100.00.00 0.00 $495.82 PERMIT ISSUANCE BASE FEE TOTAL FEES PAID BY RECEIPT: R12809 R000.322.100.00.00 0.00 $33.15 $544.84 Date Paid: Wednesday, November 15, 2017 Paid By: GINO JUDD Pay Method: CREDIT CARD 01497G Printed: Wednesday, November 15, 2017 3:40 PM 1 of 1 CIISYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT QUANTITY PAID $1,546.16 017-0299 Address: 191 SOUTHCENTER MALL Apn: 9202470130 $1,322.48 Credit Card Fee $38.52 Credit Card Fee R000.369.908.00.00 0.00 $38.52 DEVELOPMENT $1,283.96 PLAN CHECK FEE 1 R000.345.830.00.00 I 0.00 $1,283.96 M17-0158 Address: 191 SOUTHCENTER MALL Apn: 9202470130 $60.23 Credit Card Fee $1.75 Credit Card Fee 1 R000.369.908.00.00 I 0.00 I $1.75 MECHANICAL $58.48 PLAN CHECK FEE 1 R000.322.102.00.00 0.00 I $58.48 PG17-0142 Address: 191 SOUTHCENTER MALL Apn: 9202470130 $163.45 Credit Card Fee $4.76 Credit Card Fee 1 R000.369.908.00.00 I 0.00 I $4.76 PLUMBING $132.24 PLAN CHECK FEE R000.322.103.00.00 0.00 I $132.24 TECHNOLOGY FEE $26.45 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12704 R000.322.900.04.00 0.00 $26.45 $1,546.16 Date Paid: Wednesday, November 01, 2017 Paid By: ANDRES HAGEE Pay Method: CREDIT CARD 00591G Printed: Wednesday, November 01, 2017 2:00 PM 1 of 1 CL SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit l���i7 013- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V I 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:, 614°‘/0 A/ �eRy of Inspection: Typenspec PLu A /k& - t Address: 1 `l l i#e rinER /Y1 -L Date Called: Special Instructions: Date Wanted: ;2.-7`e tIL p.m: Requester: NOW PV Phone No: 200-'4792.-66g 2 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6)p PL-divt alt f) Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: cluvD geRt'i'%'IEfq' Type of Inspection: Address: /9/ s W)7,, /FA ILL Date Called: Special Instructions: A606// //' PL.U'9fl8'NC Date Wanted: 19-'.2.1-17 a m. p.m Requester: /'— Phone No: Approved per applicable codes. � Corrections required prior to approval. COMMENTS: i<- RaV M fly PL 0445/Nh oK - GRi • /Writ' elPireR inspector: Date: / 2 —2/-7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P7-0112_ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: dtOVD N) Ne CRL ivcg7 Type of Inspection: l?/"7'MT' Address: /W Sov%7fe4AriZA, Date Called: Special Instructions: /e).1/6 -hi --/At PL-O!vepv6- Date Wanted: //-2,--7-/7 a.m. P.7 Requester: Phone No: QApproved per applicable codes. D Corrections required prior to approval. COMt33EN,T,S: ,A4,044 &R /lel Inspector: 5 - Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 46) rERMIT COOR COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0142 DATE: 11/01/17 PROJECT NAME: CLOUD NINE CREAMERY SITE ADDRESS: 191 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division ass A.IA) Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 11/02/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 11/30/17 n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 Ally Plumbing Inc Horne Espanol Contact Search L&I Page 1 of 2 cif A -Z Index Help My 1 &I Safety & Health Claims & Insurance Workplace Rights Washington State Department of Labor & Industries Ally Plumbing Inc Owner or tradesperson Principals Hagee, Taylor'An Trang, MEMBER Doing business as Ally Plumbing Inc WA UBI No. 603 545 554 6617 S 193RD PL STE P 102 KENT, WA 98032 206-883-5979 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ..................................................................... Meets current requirements. License specialties GENERAL License no. ALLYPPI850PH Effective — expiration 10/08/2015-10/08/2019 Bond ............... Ironshore Indemnity Inc Bond account no. SUR40007091 $12,000.00 Received by L&I Effective date 11/15/2017 11/10/2017 Expiration date Until Canceled Bond history Insurance ............................. Western National Assur Co $1,000,000.00 Policy no. BOP1003003 Received by L&I Effective date 09/19/2017 10/07/2015 Expiration date 10/07/2018 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. LSI Tax debts No LSI tax debts are recorded for this contractor license during the previous 6 year period, ut some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603545554&LIC=ALLYPPI850PH&SAW= 11/15/2017 Ally Plumbing Inc Page 2 of 2 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 615,163-00 ................................. Doing business as ALLY PLUMBING Estimated workers reported Quarter 3 of Year 2017 "21 to 30 Workers" L&I account contact T1 / TYRONE COLEMAN (360)902-4807 - Email: COTI235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........................................ .............. No strikes have been issued against this contractor. Contractors not allowed to bid ........................_..................................................._............ No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603545554&LIC=ALLYPPI850PH&SAW= 11/15/2017 2 4 5 6 7 8 9 10 A 1 B I 1 WATER HEATER, SEE FS PLANS D PROVIDE W/ HEAT TRAP & R-10 INSULATED BASE PER WSEC, & EXPANSION TANK (3 GAL) P -1A P-1 A E P-11 C F I � I H P-11 C P -11A 3/4"HWC TO CP -1 7 - P-11 A 1"HW P -3A G) I 1 L_J 1iil�t!!I L _I L i P-11 A 3"VTR P -3A 1"CW 1"CW 1-1/4"CW, CONNECT 73/4"HWC TO (E) CW SERVICE MAIN D P-11 A ---� I 4"VTR I1 (1\ I 1 0 --4--.-- (E) PIPING ABANDONED IN PLACE DEMO & CAP UNUSED PIPING AS SHOWN P-11 C PLUMBING PLAN 1"HW SCALE: 1/4 " = 1'-0" E P-11 C 1' 4' 0' 2' F SCALE 1/4" = 1'-0" 8' P -11A — 1"HW 1 P-11 C G REVISIONS No changes shall he made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: IirMechanical 6 tiectricai ❑ Plymbing 1t�Gas Piping City of Tukwila Bsii-DINO DIVISION J VERIFY LOCATION OF PIPE DROP TO CLEAR WINDOW FILE COPY Permit No. ?G1'7- D P-14 Plan review approval is culgoct to Approval of construction the violation of any adopt of approved Feld Copy By: Date: ///# S/i 7 GENERAL NOTES: 1. SEE NOTES SHEET M0.1. City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED NOV 14 2017'D City of TllkWila 2. SEE FOOD SERVICE (FS) PLANS & SPECIFICATIONS FOR ADDITIONAL MECHANICAL WORK. ALL ITEMS REQUIRING PLUMBING CONNECTIONS SHALL BE COMPLETELY CONNECTED BY PLUMBING CONTRACTOR. 3. PROVIDE INDIRECT DRAINS FOR ITEMS AS NOTED ON FS PLANS. 4. ROUTE CIRCULATED HW PIPING AS CLOSE TO DROP TO HAND WASH SINKS AS POSSIBLE (TO MEET CODE REQ'D TIMING FOR HW AT FIXTURE). 5. CAP OFF ALL UNUSED PLUMBING. 6. PROVIDE CW PIPING TO TRAP PRIMER VALVES TO SERVE FLOOR DRAINS & FLOOR RECEPTORS. KEYED NOTES: OPROVIDE W/ SEISMIC STRAPS TO WALL. PIPE RELIEF VALVE FULL SIZE, TO ADJACENT FLOOR DRAIN. H K RECEIVED CITY OF TUKWILA 1,17 PERMIT CENTER PUrk011+1 J K 1 2 3 4 6 7 8 9 10 U PO 0 N°' a) 1111 Fawcett Ave Suite 100 to N co ) O co E 0 U L 0 <) i L C- a� (/) Z W1711; 0 w I_1_ J U it g D �-- O� J 0 Z SIGNED 10-25-2017 SHEET TITLE: PLUMBING PLAN CHECKED: RH DRAWN: NH DATE: 10.25.17 REVISIONS: M3.0 0"1" 2" / I 1,0:1 rz/ SHEET SIZE IS TRUE SCALE WHEN ABOVE LINE MEASURES AS NOTED 8' 11" 1'-5" —'Ica 1'-3" --a 4" 25'-3" a 5" p a 4" -ada.- 4. i) 3' 5" —r— 2' 7" --utt'') 1' 31'-3" 4" 4' 5" a 3" — 5" 6' 11" 9'-11" 14'-5" 58' 3" FOODSEWCE EQUIPVE\T as 4" — 4" 12" SQ. —7/8" SQ. TRAP SEAL PRIMERS No form of trap that depends for its seal upon the action of movable parts shall be used. Each fixture trap shall have a liquid seal...and shall be protected from freezing. Floor drain or similar traps directly connected to the drainage system and subject to infrequent use shall be protected with a trap seal primer. Trap seal primers shall be directly connected to the water supply and shall be accessible for maintenance. (2015 UPC 1005.0, 1006.0 & 1007.0) 6" 9-1 /8" 4" 12" X 12" FLOO SI\ -TAIL SCALE: NTS \DRECT FU\ ild \EL D �Alf� WASTE DETAIL SCALE: NTS 9'0 6.0 ``/151%1%1►J1%1%1►.121%1F 21 2-7/8' •1-► tip i A A� • ••� 2' 1' 2' Al 6-17/32' 6 1/16' I\DRECT FLOO DAIN WASTE 2"-3" IP DETAIL SCALE: NTS A WD Series Tag: WD -25 PDI Certified Grease. Interceptor SPECIFICATION: Watts Drainage WD Series PDI Certified recessed or Noor mounted epoxy coated steel grease interceptor with gasketed epoxy coated steel skid -proof cover secured with hex head center bolt(s), removable baffle assembly, deep seal trap with cleanout, external cast iron flow control fitting, and no hub (standard) connections. A-- J. 1n= Flow Restrictor w/Vent Connection .41,115 D (Length) x E (Width) ISO 9002; CERTIFIED 1 Outlet 4. 7 10 15 20 / 25 ✓ 35 50 4 GPM 7 GPM 10 GPM 15 GPM 20 GPM 25 GPM 35 GPM 50 GPM 0 0 0 0 0 -E -FC -HD -O -SS THD Sediment Bucket Extension Flange & Clamp Device Heavy Duty (10,000 lb.)Traffic Cover* Inlet & Outlet other than Standard Size Stainless Steel Threaded Connections 0 0 0 *HD Options Requires Minimum3" Extension WD -4 4 WD -7 7 WD -to 10 WD -15 15 WD -20 20 WD -25 25 WD -35 35 WD -50, 50 8 2"(51) 7-3/41197) 14 2"(51) 8-1/212.16) 20 2"(5T) 8-1/2"(216) 3-1/4"(83) 16'(406) 3-1/2"(89) 189457) 31/2"(89) 21-3/4"(552) 10"(254) 13"(330) 14"P50) 1 1"(279) 12"(305) 12"(305) 30 2"(51) 10.1/29267) 3-1/2"(89) 22"(559) 15" (381) 14"(356) 40 3,"(76) 11-1/29292)` 3-1/2.1891 50 3"(76) 12"(305) 70 3976) 14"(356) 41/21114) 5"(127) 24"(610) 26"(660) 30"(762) 100 4"(102) 169406) 5-1/29140) 329813) 15-3/4"(400) 15"(381) 16-1/21419) 16-1/2"(419) 18"(457) 191483). 22"(559) 21-1/29546) NOTICE w. , The information contained herein is not intended to replace the full product installation and safety Information available or the experience of a trained product installer. You are required to thoroughly read all installation and product safety information before beginning the installation of this product: Job Name CLOUDNINE CREAMERY Job Location SOUTHCENTER MALL SPACE #700 Contractor ALLY PLUMBING Contractor's' P.O. No Engineer Representative Watts product specifications in U.S. customary units and metric are approximateand are provided for reference only. For precise measurements, please contact Watts Technical Service: Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.. USA: Tel: (800) 338-2581 • Fax: (828) 248-3929 • Watts.com Canada: Tel: (905)'332-4090 • Fax: (905) 332-7068 • Watts.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52)81-8000-7091 • Watts.com ES -WD -WD -SERIES -USA 1713 © 2017 Watts GOU\D 91 CETIFIED GREASE I\ TE CEPTCH SCALE: NTS PLU V 31\ G L -G \D 0 DRAIN LINE IN WALLS HOT WATER LINE COLD WATER LINE 12"x 12" FLOOR SINK WITH SEDIMENT BUCKET AND S/S SCREEN FLOOR DRAIN FD FLOOR DRAIN WITH FUNNEL 0 STUB UP 6" HOT & COLD WATER LINES G STRAINER. DRAIN LINE TO FLOOR SINK OR FLOOR DRAIN WITH FUNNEL DRAIN. SAL PL V31\G \OTES 1. ALL DIMENSIONS SHOWN ARE FROM FINISHED BUILDING SURFACES TO CENTER LINE OF DRAINS & WATER SUPPLY LINES 2. PLUMBER TO FURNISH ALL VALVES, TRAPS, FLOOR SINKS, FLOOR DRAINS, GREASE TRAP, & BACKFLOW PREVENTION DEVICES UNLESS FURNISHED BY EQUIPMENT MFG. MACHINES. 3. PLUMBER TO FURNISH LINE STRAINER FOR ICE MACHINE. 4. PLUMBER SHALL VERIFY REQUIREMENTS OF ALL OWNER AND VENDOR FURNISHED EQUIPMENT. 5, THIS PLAN RELATES TO FOOD SERVICE EQUIPMENT ONLY. PLUMBER SHALL VERIFY ANY ADDITIONAL PLUMBING THAT MAY BE REQUIRED BY THE TENANT OR BUILDING OWNER. 6. THIS INSTALLATION SHALL BE MADE IN ACCORDANCE WITH ALL APPLICABLE CODES. 7, 3 COMP POT / PAN SINK THAT WILL GENERATE GREASE TYPE WASTE MATERIALS SHALL DISCHARGE INTO THE WATTS GREASE INTERCEPTOR. PLUV 31 \G <EY \OTES NOTE: A.F.F.=ABOVE FINISHED FLOOR, HW=HOT WATER LINE, CW=COLD WATER LINE. O ALIGN FLOOR SINKS 0 2"IPS DRAIN PIPE STUB UP 2-3/4" FOR ITEM #2 FLOOR MOP SINK 0 2" DR +14" A.F.F. 1/2" HW / CW +17" A.F.F. FOR ITEM #4, ITEM #8, ITEM#10, ITEM #30 & PUBLIC RESTROOM HAND SINKS. 1/2" NPT FEMALE HOT WATER CONNECTION 60" A.F.F FOR ITEM #6 DISHMACHINE. BACKFLOW PROTECTION PROVIDED BY ASSE 1001 VACUUM BREAKER INCLUDED WITH MACHINE SEE SPECIFICATION SHEET. O RUN INDIRECT DRAIN LINE FOR ITEM #6 DISHWASHER TO FLOOR SINK FS -1 AS REQUIRED. O RUN THREE COMP SINK DRAINS ITEM #10 TO GREASE INTERCEPTOR AS REQUIRED BY CODE. O 1/2" HW / CW +17" A.F.F. O RUN INDIRECT DRAIN LINE FOR ITEM #13 PREP SINK TO FLOOR SINK FS -2 AS REQUIRED. O1/2" CW DEDICATED COPPER SUPPLY LINE. STUB UP +6" A.F.F RUN TO ITEM #18 COCA—COLA FREESTYLE BEVER DISPENSER AS REQUIRED. SEE COCA—COLA FREESTYLE 7000 INSTALLATION GUIDELINES FOR FURTHER INFORMATION. 10 RUN INDIRECT DRAIN LINE FOR ITEM #18 COCA—COLA FREESTYLE BEVERAGE DISPENSER TO FLOOR SINK FS -3 AS REQUIRED. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 14 2017 City of Tukwila § 1I • 11 WATER FILTRATION SYSTEM FOR ITEM #18 COCA—COLA FREESTYLE BEVERAGE DISPENSER SHALL MEET NSF STANDARD 42. 12 ITEM #18 COCA—COLA FREESTYLE BEVERAGE DISPENSER ARE PROVIDED WITH ASEE 1022 BACKFLOW PREVENTION DEVICES. A 13 ITEM #20 DROP—IN COLD PAN RUN 1" INDIRECT DRAIN LINE AS REQUIRED TO FLOOR DRAIN WITH 6" FUNNEL DRAIN TO CREATE CODE REQUIRED 2" AIR GAP. 14 3/4" HW +17" A.F.F. FOR ITEM #27 S/S MIXING BOWL THAW SINKS. RUN LINES IN CABINETRY TO SINKS AS REQUIRED. 15 RUN 2" INDIRECT DRAIN LINE FOR ITEM #27 S/S MIXING BOWL THAW SINKS TO FLOOR SINKS FS -4, FS -5, & FS -6 AS REQUIRED. 1s 16 3/8" CW +14" A.F.F. RUN TO WATER FILTRATION SYSTEM ITEM #73 MANITOWOC ARCTIC PURE #AR -10000 AS REQUIRED. FROM WATER FILTER RUN 3/8" LINE TO ITEM #33 UNDER COUNTER ICE MAKER AS REQUIRED. 17 ITEM #33 U/C ICE MAKER RUN 1/2" INDIRECT DRAIN LINE AS REQUIRED TO FLOOR DRAIN WITH 6" FUNNEL DRAIN TO CREATE CODE REQUIRED 2"AIR GAP. O3/4" CW +48" A.F.F. FOR ITEM #46 AUTOMATIC ESPRESSO BREWER. RUN TO BREWER AS REQUIRED. PLUMBER SHALL VERIFY PURVEYOR MAKE AND MODEL # PRIOR TO INSTALLATION OF AUTOMATIC ESPRESSO BREWER. ® 1/2" HW / CW +36" A.F.F. 20 HW +72" A.F.F. FOR 1-1/2" HOT WATER INLET FROM ITEM #53 ELECTRIC HOT WATER HEATER. RUN HW SUPPLY LINES TO ALL EQUIPMENT & FIXTURES REQUIRING HW AS REQUIRED BY CODE. 21 1-1/2" CW +5" A.F.F. FOR ITEM #53 ELECTRIC WATER HEATER. 22 FLOOR DRAIN WITH FUNNEL FOR ITEM #53 ELECTRIC HOT WATER DRAINAGE. 23 PLUMBER SHALL VERIFY MAKE AND MODEL OF TOILET TO BE USED AND VERIFY THE TOILET DRAIN SIZE REQUIRED AT TIME OF ROUGH—IN DRAIN INSTALLATION. 24 1/2" CW +8" A.F.F. 25 NOTE: ALL ROUGH—IN PLUMBING DRAIN LINES & WATER LINES SHALL START FROM INSIDE FINISHED FACE OF EXISTING REAR EXIT DOOR. NOTE: PUBLIC HEALTH — KING COUNTY INSPECTION REQUIRED ON COMPLETION OF WORK PRIOR TO OPENING. NO CHANGES WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL. 1)G RECEIVED CITY OP TUKWILA 1 e7 PER11/IIT CENTER i'. r7o19z RECEIVED NOV 0 2 2017 TUKWILA PUBLIC WORKS C9 z z z g FOODSERVICE INTERIOR DESIGN Design Associates 6402 S Verde St Tacoma, WA. 98409 PH 206-354-7200 F0c0Sit1V Ecoosuaritirs PROJECT NAME CLOUD NINE CREAMERY 191 SOUTHCENTER SPACE #700 TUKWILA, WA. 98188 DESIGN TEAM PROJECT NO.: 05-2017 PRINCIPAL LU SCHILDMEYER DRAWN BY: LS CHECKED BY: LAS ISSUED/REVISIONS 9-12-17 ISSUE FOR STRUCT SLAB REVIEW 10-30-17 ISSUE FOR 11 PERMIT SUBMITTAL PROJECT CONSULTANTS SHEET TITLE FOODS ERVICE EQUIPMENT ROUGH -IN PLUMBING & DRAIN PLAN SHEET NO. FS -4.0