Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG17-0169 - FLOOR & DECOR - GAS PIPING, NATURAL GAS METER
FLOOR & DECOR 17601 SOUTHCENTER PKWY PGI 7-0169 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 3523049088 17601 SOUTHCENTER PKWY Project Name: FLOOR & DECOR Permit Number: PG17-0169 Issue Date: Permit Expires On: 12/20/2017 6/18/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: LEVITZTUKWILA LLC 180 N STETSON AVE #324-D , CHICAGO, WA, 80601 HEATH HAMBLEN 4102 B PLACE NW , AUBURN, WA, 98001 UNIVERSAL REFRIGERATION INC PO BOX 614 , AUBURN, WA, 98071- 0614 UNIVERI159RF I 1 1 Phone: (253) 939-5501 Phone: (253) 939-5501 Expiration Date: 4/1/2018 DESCRIPTION OF WORK: INSTALL (1) 2" DIAMETER NATURAL GAS PIPING INTO TENANT SPACE FOR FUTURE BUILD -OUT. RECONNECT ASHLEY FURNITURE TO NEW NATURAL GAS METER. Valuation of Work: $4,594.00 Water District: HIGHLINE Sewer District: TUKWILA Fees Collected: $129.28 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to • • o , ditions attached to this permit. Signatur-• --rrll /' Print Name: H 6-44-A )iA04b/nJ Date: 12/25/1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless priorapprovalis obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING 9001 UNDERGROUND CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Plumbing/Gas Permit No. Project No. 6fti oitA Date Application Accepted: Date Application Expires: (For office use only) 12,13-11 PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 1'7 UM 50 ,1 C.36o7R4 Tenant Name: C1 neat x71 4 2HL. "Tri. . King Co Assessor's Tax No.: 35.2.3044O1,1 Suite Number: PROPERTY OWNER Name: Levi 14-T4104:6 LLC. I Address: lies A. S46)4 $6.324o City: C1ol.LAGO State:. t. Zip:60(41 CONTACT PERSON — person receiving all project communication Name: Bryan ea Shane Chuck Address: 4102 B PI NW , r - GtYt'\rev\ City: Auburn State: WA 0 Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Email: bf►Ain I. @universalrefrg.com � Floor: New Tenant: Q Yes ❑..No PLUMBING CONTRACTOR INFORMATION Company Name: Universal Refrigeration Address: 4102 B P1 NW City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Contr Reg No.: UNIVERI 159RF Exp Date: 04/01/2018 Tukwila Business License No.: BUS -0993124 Valuation of Project (contractor's bid price): $ •( 5q 4 . Scope of Work (please provide detailed information): ` TNsVAll (,t� 2tif tu„IvaAa sots ';sp:Nsn410 -f. " 3lr S' Lb iu CiorL �\`uft.k: ou'a bU - . 1<tCe�ln�tct,�- pS�lt�v2wli��fLt �-a nlrrcJ 414V1i.0.\ SAS vote Won- Building r v _Building Use (per t'l Building Code). Occupancy (per lnt'1 Building Code): Utility Purveyor: Water: Sewer. H:\Applications\Fonns-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 = , gallon capacity) • • Each additional medical gas inlets/outlets greater than 5 ' Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater.and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller ' Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Bgkfltvtprotecti've"°:: device other than • • - atmospheric -type " vacuum breakers over 2 inch (51 mm) diameter ' Gas piping outlets 1 Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas. Each lawn sprinkler systeat on any one meter including backflow protection devices PERMIT APPLICATION NOTES -. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER ORAUTHORd'ZL�I)rAGENT: Signature: Print Name: Jerry Aeschlimann Mailing Address: 4102 B P1 NW r H:Wpplications\Fonns-Applications On Line \2011 Applications\Plumbing Pennit Application Revised 8-9-1 l.docx Revised: August 2011 bh Date: II /2.8/1-1 • Day Telephone: (253) 939-5501 Auburn City .E s •c WA 98001 State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $104.42 PG17-0169 Address: 17601 SOUTHCENTER PKWY Apn: 3523049088 $104.42 GAS $99.45 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $66.30 TECHNOLOGY FEE $4.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13065 R000.322.900.04.00 0.00 $4.97 $104.42 Date Paid: Wednesday, December 20, 2017 Paid By: UNIVERSAL REFRIGERATION Pay Method: CHECK 52792 Printed: Wednesday, December 20, 2017 11:07 1 of 1 AM CSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS QUANTITY PAID $24.86 $24.86 $24.86 $24.86 $24.86 PermitTRAK PG17-0169 Address: 17601 SOUTHCENTER PKWY Apn: 3523049088 GAS PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R13018 R000.322.103.00.00 0.00 Date Paid: Wednesday, December 13, 2017 Paid By: UNIVERSAL REFRIGERATION Pay Method: CHECK 52787 Printed: Wednesday, December 13, 2017 12:18 1 of 1 PM CIMSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: i i' /9%AC Type of Inspection: Gam' Pi eX Address: Date Called: Special Instructions: INV— PROSSORr 7ZST Date Wanted: a.m. p.m. Requester: MVK i Phone No: -2-6-3 .- 242(0- I 5-5 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: G/1-5 TIPI Rz0/# Inspector: IripS Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 F6!7-bHQq Project: noon 4' Decd Type of Inspection: gotmil-lid 645 PiP(N6- Address: rucei 'oG"n~!•CANTER tray Date Called: Special Instructions: Mfyitir G s- Date Wanted: a.rri~ I --(.0 —1 p. • Requester: V Phone No: -2-63-21*-teats Approved per applicable codes. aCorrections required prior to approval. COMMENTS: 77-57— //07—/y'L (6 PR—if Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT C HORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0169 DATE: 12/13/17 PROJECT NAME: FLOOR & DECOR SITE ADDRESS: 17601 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: /T (7 t lding Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 12/14/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/11/18 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) . (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 UNIVERSAL REFRIGERATION TNTC Ito nc Espanol Contact. Safety & Health Claims & Insurance CpWashington State Department of Labor & industries Search L&I Page 1 of 2 A -Z index Help My I.CI Workplace Rights Trades & Licensing UNIVERSAL REFRIGERATION INC Owner or tradesperson Principals GATES, CHRISTOPHER A, PRESIDENT GALVIN, BRYAN S, VICE PRESIDENT GATES, CHRIS A, AGENT VERNON, GUY E (End: 01/01/1980) JACKSON, SHELDON G (End: 01/01/1980) OSENBAUGH, CHARLES R (End: 01/01/1980) RAEDER, STEVEN C, PRESIDENT (End: 03/29/2012) Doing business as UNIVERSAL REFRIGERATION INC WA UBI No. 600 599 723 PO BOX 614 AUBURN, WA 98071-0614 253-939-5501 KING County Business type Corporation Governing persons BRYAN GALVIN CHRIS GATES; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties COMMERCIAL/INDUSTRIAL/REFRIG License no. UNIVERI159RF Effective — expiration 12/06/1985— 04/01/2018 Bond AMERICAN STATES INS CO Bond account no. EX903622 $6,000.00 Received by L&I Effective date 03/18/2002 12/06/2001 Expiration date Until Canceled Insurance Ohio Cas Ins Co Policy no. $1,000,000.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=UNIVERI159RF&SAW= 12/15/2017 ASHLEY FURNITURE 65,459 SF (EXISTING) 1,486 CFH/1,560 MBH @ 500' EXISTING NEW 2" NATURAL GAS LINE P.O.C. STUBBED AND CAPPED AT TRUSS LEVEL FOR FUTURE BUILD -OUT UNDER SEPERATE MECHANICAL PERMIT 3,179 CFH/3,338 MBH @ 600' FLOORS & DECOR 89,939 SF (EXISTING) DEMO EXISTING GAS PIPING RELOCATION OF EXISTING 2 PSI NATURAL GAS METER (BY PSE) EXISTING GAS METER (2 PSI) NOTE: These plans are diagrammatical only. Please verify all dimensions at job site. GAS PIPING PLAN SCALE: 1" = 30'-0" !SE > 'ME PERMIT -..e` 7i3 FOR: L chanical I hctrical Plumbing 0 Gas Piping city of Tukwila B1JI171DING DIVISION HVAC LEGEND HVAC ABBREVIATIONS (ED 0 INLINE EXHAUST FAN(S) AFF BDD BTUH CD CFM CU DB DH DOAS DN EC EER EF EG ERV ESP EXH FCU FD FPM FSD GA GF GRD HP ID IHP IRH KW MBH MCD NC NIC NTS OBD OC OD OHP OSA OSCI POC RA RAG RPM RTU SA SG SP SSG TBD TG TYP UH VFD VTR VVT ABOVE FINISHED FLOOR BACKDRAFT DAMPER BRITISH THERMAL UNIT PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CONDENSING UNIT DECIBEL DUCT HEATER DEDICATED OUTSIDE AIR SYSTEM DOWN EVAPORATOR COIL ENERGY EFFICIENCY RATIO EXHAUST FAN EXHAUST GRILLE ENERGY RECOVERY VENTILATOR EXTERNAL STATIC PRESSURE EXHAUST FAN COIL UNIT FIRE DAMPER, FLOOR DRAIN FEET PER MINUTE FIRE AND SMOKE DAMPER GAUGE GAS FURNACE GRILLE, REGISTER, DIFFUSER HORSEPOWER, HEAT PUMP INSIDE DIMENSION INDOOR (SECTION) HEAT PUMP INFRARED HEATER KILOWATT THOUSAND BTU PER HOUR MOTORIZED CONTROL DAMPER NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIMENSION OR DIAMETER OUTDOOR HEAT PUMP OUTSIDE AIR OWNER SUPPLIED CONTRACTOR INSTALLED POINT OF CONNECTION RETURN AIR RETURN AIR GRILLE REVOLUTIONS PER MINUTE ROOFTOP UNIT SUPPLY AIR SUPPLY GRILLE STATIC PRESSURE SIDEWALL SUPPLY GRILLE TO BE DETERMINED TRANSFER GRILLE TYPICAL UNIT HEATER VARIABLE FREQUENCY DRIVE VENT TO ROOF VARIABLE VOLUME AND TEMPERATURE ' !SE > 'ME PERMIT -..e` 7i3 FOR: L chanical I hctrical Plumbing 0 Gas Piping city of Tukwila B1JI171DING DIVISION HVAC LEGEND 1. REWORK EXISTING NATURAL GAS PIPING TO ACCOMODATE NEW METER LOCATION. 2. DEMO EXISTING GAS PIPING. (ED 0 INLINE EXHAUST FAN(S) ROOFTOP EXHAUST FAN ' ) IIISIDEWALL EXHAUST FAN ■ VAV FAN BOX 1 CEILING EXHAUST FAN F OM GAS METER ZD12 VVT DAMPER 0 THERMOSTAT T -BAR SUPPLY DIFFUSER T -BAR RETURN GRILLE HARDLID SUPPLY DIFFUSER L HARDLID RETURN GRILLE FD FIRE DAMPER FSD FIRE SMOKE DAMPER VOLUME DAMPER Lam- SD SMOKE DETECTOR FLEXIBLE DUCT SA/RA 0 ROUND DUCT UP i ROUND DUCT DOWN DIFFUSER TAG (301021COTP0) !SE > 'ME PERMIT -..e` 7i3 FOR: L chanical I hctrical Plumbing 0 Gas Piping city of Tukwila B1JI171DING DIVISION FILE COPY Permit Ido. 1 `7 ` U 1 tD 1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy an....d ons is acknowledged: te: ,_ /2/2-4%j-7 City of Tukwila BUILDING DIVISION REVISIONS No changes shall he made to the scope of work withr?,1 'mor approval of ' ; r';,�•il � BuiicIin Divi ��-� _ - 9 Division. 1 I�:i.) ._: i �evisicris will require a new plan submittal j and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1.4 2017 k7 City of Tukwila u voila. BI J I I D I tG.-GYt,k RECEIVED CITY OF TUKWILA DEC 13 2017 PERMIT CENTER P&rioI? - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 PRINT/PLOT DATE: 12/11/17 DRAFTER: DESIGNER: PROJECT MANAGER: JOB NUMBER: 17243 SHEET NUMBER: EPENJDINJG CITY APPROVAL HVAC NOTES 1. REWORK EXISTING NATURAL GAS PIPING TO ACCOMODATE NEW METER LOCATION. 2. DEMO EXISTING GAS PIPING. 1. DUCT INSULATION TO MEET THE REQUIREMENTS OF SECT- ION C403.2.8 OF THE 2015 WSEC AND SECTION 604 OF THE IECC (INTERNATIONAL ENERGY CONSERVATION CODE). 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AIR DUCTS PER SECTION 606 OF THE 2015 IMC. HVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNIT UPON ACTIVATION AND A "SUPERVISORY" ZONE SHALL BE INITIATED AT FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION 606.2.1. 3. DUCTWORK-MAINTRUNK IS R-4.2 IN CONDITIONED SPACES AND R-8 IN UNCONDITIONED SPACES AS PER THE WSEC. 4. ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED WITH ECONOMIZERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS PER I.M.C. 2015, SECTION 403, CHAPTER 6, AND SHALL OPERATE, PER W.S.E.C. 2015, SECTION C403.3.1. 5. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON-SITE FOR INSPECTIONS. 6. ALL HVAC EQMT. TO BE LABELED TO THE SPACE SERVED. 7. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE VERTICAL AT 12'-0" MAX., HORIZONTAL AT 10'-0" MAX. WITH STRAP, OR 8'-0" MAX. F TRAPEZE SUPPORT. 8. THERMOSTAT TO BE SEVEN-DAY TYPE AND HAVE NIGHT SETBACK WITH 5 DEGREE DEADBAND. 9. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF C408 WSEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, O&M MANUALS, SYSTEM BALANCE REPORT, AND A COMMIS- SIONING REPORT. 10. DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC C403.2.8. DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED AS FOLLOWS: 1. STATIC PRESSURE 1/2 INCH TO 3 INCHES: SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. SPIRAL LOCK SEAMS IN ROUND AND FLAT OVAL DUCT WORK DO NOT REQUIRE SEALING; HOWEVER, OTHER SEAMS SHALL BE SEALED. 2. STATIC PRESSURE ABOVE 3 INCHES: SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS. 11. WSEC FORMS, DUCTING PLANS, BALANCING FEATURES, AS WELL AS VENTILATION REQUIREMENTS (AS PER TABLE 403.3.1.1, 2015 IMC MINIMUM VENTILATION RATES) AND OCCUPANCY, ALONG WITH A MECHANICAL PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. FILE COPY Permit Ido. 1 `7 ` U 1 tD 1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy an....d ons is acknowledged: te: ,_ /2/2-4%j-7 City of Tukwila BUILDING DIVISION REVISIONS No changes shall he made to the scope of work withr?,1 'mor approval of ' ; r';,�•il � BuiicIin Divi ��-� _ - 9 Division. 1 I�:i.) ._: i �evisicris will require a new plan submittal j and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1.4 2017 k7 City of Tukwila u voila. BI J I I D I tG.-GYt,k RECEIVED CITY OF TUKWILA DEC 13 2017 PERMIT CENTER P&rioI? - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 PRINT/PLOT DATE: 12/11/17 DRAFTER: DESIGNER: PROJECT MANAGER: JOB NUMBER: 17243 SHEET NUMBER: EPENJDINJG CITY APPROVAL SCOPE OF WORK JOB# 17243 1. REWORK EXISTING NATURAL GAS PIPING TO ACCOMODATE NEW METER LOCATION. 2. DEMO EXISTING GAS PIPING. FILE COPY Permit Ido. 1 `7 ` U 1 tD 1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy an....d ons is acknowledged: te: ,_ /2/2-4%j-7 City of Tukwila BUILDING DIVISION REVISIONS No changes shall he made to the scope of work withr?,1 'mor approval of ' ; r';,�•il � BuiicIin Divi ��-� _ - 9 Division. 1 I�:i.) ._: i �evisicris will require a new plan submittal j and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1.4 2017 k7 City of Tukwila u voila. BI J I I D I tG.-GYt,k RECEIVED CITY OF TUKWILA DEC 13 2017 PERMIT CENTER P&rioI? - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 PRINT/PLOT DATE: 12/11/17 DRAFTER: DESIGNER: PROJECT MANAGER: JOB NUMBER: 17243 SHEET NUMBER: EPENJDINJG CITY APPROVAL