Loading...
HomeMy WebLinkAboutPermit PG17-0176 - SEATAC LIGHTING - PLUMBINGSEATAC LIGHTING 15455 53RD AVE S PGI 7-0176 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1157200044 15455 53RD AVE S SEATAC LIGHTING PLUMBING/GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG 17-0176 1/12/2018 7/11/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SEA -TAC LIGHTING CORPORATE 15455 53RD AVE S , TUKWILA, WA, 98188 RYAN MCMAHAN 35920 2074TH PL SE , AUBURN, WA, 98092 REDLINE MECHANICAL PO BOX 721, ENUMCLAW, WA, 98022 REDLIM*835MM Phone: (253) 939-6398 Phone: (253) 939-6398 Expiration Date: 7/14/2019 DESCRIPTION OF WORK: PLUMBING FOR TI Valuation of Work: $64,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $616.18 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: `" (�� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or Ia Taw regulating construction or the performance of work. I am authorized to sign and obtain this develo• ment per it andgree to the conditions attached to this permit. Signatu : Print Name: Date: I _ (2_ 2-9 to This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUK f,...,A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No. Date Application Accepted: 11 Oh Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 1 5- 4, S Tenant Name: Suite Number: PROPERTY OWNER Name: Onn I }� ,1 `� l 610 aeircl Address:. Name: JQRra_c_, u ,3 k(1 I � p ..' .L State.. Zipqm A.t Address: (Sq Ss 63 "A s Email: Q�� pp? A City: TI -a-4.4 3A & State: �k Zip:Oj8l Q CONTACT PERSON — person receiving all project communication Name: Onn I }� ,1 `� l 610 aeircl Address:. g 20 2/ J s : , Citylit l I � p ..' .L State.. Zipqm A.t Phone; 63'9 31—(0 /' be- 29o -73o -3'14.0D Email: Q�� pp? A Contr Reg No.: ath L .e., 3SI.A xp Date: Floor: New Tenant: Yes PLUMBING CONTRACTOR INFORMATION Company Name: 1/ n A u i (14A.c J Address: SSG\ 20 20-p-, P sem. City: n_ /j_l State: Zip �Z Phone:2.6-3-1 yi_(0,6) o ax: Contr Reg No.: ath L .e., 3SI.A xp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $�Y 1 � Scope of Work (please provide detailed information): Building Use (per Int'1 Building Code): Occupancy (per IInt'1 Building Code): Utility Purveyor: Water: Sewer H:\Applications\Forns-Applications On Line\2011 Applications\ Plumbing Permit Application Revised 8-9-11.doex Revised: August 2011 bh Page 1of2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain I Shower, single head trap 6 Sinks 12 - ZIndustrial Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) I Lavatory 6 Urinal 12 - ZIndustrial Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 • Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet 12 - ZIndustrial Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction —In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING NER OR AI T, HORIZE AGENT: Signature: �JI�'11{I Print Name: I. l C O M G (V .o.r. Day Telephone: Date: ��O'% 7 Mailing Address: ?. 0 . p)G T2j HAApplications On Line \2011 Application.<\Phumbing Pcrmit Application Revised 8-9-11.docx Revised: August 2011 bh City A /""" State Zip Page 2 of 2 r.47,NILA CI �190� Cash Register Receipt City of Tukwila Receipt Number R13350 DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $494.83 PG17-0176 Address: 15455 53RD AVE S Apn: 1157200044 $494.83 PLUMBING $471.27 PERMIT FEE R000.322.100.00.00 0.00 $438.12 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $23.56 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13350 R000.322.900.04.00 0.00 $23.56 $494.83 a Date Paid: Friday, January 12, 2018 Paid By: REDLINE MECHANICAL Pay Method: CHECK 1066 Printed: Friday, January 12, 2018 7:34 AM 1 of 1 CSYSTEMS Cash. Register Receipt City of Tukwila Receipt Number R1.3100 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $121.35 PG17-0176 Address: 15455 53RD AVE S Apn: 1157200044 $121.35 Credit Card Fee $3.53 Credit Card Fee R000.369.908.00.00 0.00 $3.53 PLUMBING $117.82 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R13100 R000.322.103.00.00 0.00 $117.82 $121.35 Date Paid: Tuesday, December 26, 2017 Paid By: NICOLE MCMAHAN Pay Method: CREDIT CARD 716201 Printed: Tuesday, December 26, 2017 3:10 PM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION W7- One, 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Proje d � 1-, �, Ty Inspect' n� Fryjitott Address: '+fid Called: Date Called: pedal Instructions: C ---Pt, r l Date Wanted: J r a Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector7c i Date:? 11_, 24vf( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P6 7-0/76 Project: - Sem-. l c �) � T e of Inspection: Kb u C1 io P itA,rt.i Address:Date / CV55 53 Ayr_ S . , C ed: ----.. Special Instructions: Date Wanted: 3—Z2 -2-0/ (- Ca.ti p.m. Requester: Phone No: F ¢ JApproved per applicable codes.Corrections required prior to approval. COMMENTS: Fe3iLkr:Ok n A Inspector( s1.p_ „ Date: 3 22 ?4lg' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ?r7 -o J7l4 Project: 6-5/1.771C£i6-1-7'7NG Type of Inspection: 6,1 6,'O wk Address:1 L s 6r 50RD/ft Date Called: Special Instructions: 6P6,1 tve>fa< AFT -A-& 9d9- l Date Wanted: I --1i-ia (a.m' p.m. Requester: ChIA Lc Phone No: '2C"' -963.- 706-3 3 C041 -1.-r79- Approved per applicable codes. E] Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ''ERMiT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0176 DATE: 12/27/17 PROJECT NAME: SEATAC LIGHTING SITE ADDRESS: 15455 53RD AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division DWI V;\(6 Public Works Fire Prevention Structural n Planning Division CPermit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 12/28/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 01/25/18 ❑ Approved with Conditions n Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation:\C-fis,• yV - V) I REVIEWER'S INITIALS: DATE: Pennit Center. Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 REDLINE MECHANICAL Home E:spaf of Contact. Safety & Health Washington State Department of kl Labor & Industries Search L&I A-Lindex Help Page 1 of 2 My la Claims & Insurance Workplace Rights Trades & Licensing REDLINE MECHANICAL Owner or tradesperson Principals MCMAHAN, NICOLE LYN, PARTNER/MEMBER Doing business as REDLINE MECHANICAL WA UBI No. 604 125 856 Parent company REDLINE PLUMBING LLC PO BOX 721 ENUMCLAW, WA 98022 253-939-6398 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .............................................._.. _............. Meets current requirements. License specialties GENERAL License no. REDLIM*835MM Effective — expiration 07/14/2017— 07/14/2019 Bond Wesco Insurance Co Bond account no. 46WB087494 $12,000.00 Received by L&I Effective date 07/14/2017 07/12/2017 Expiration date Until Canceled Insurance ............................ Ohio Security Ins Co $1,000,000.00 Policy no. BKS58094496 Received by L&I Effective date 07/14/2017 07/12/2017 Expiration date 07/12/2018 Savings .............. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ........... No L&l tax debts are recorded for this contractor license during the previous 6 year period, ut some debts may be recorded by other agencies. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=604125856&LIC=REDLIM*835MM&SAW= 1/12/2018 REDLINE MECHANICAL License Violations .................................................._... No license violations during the previous 6 , period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 274,801-01 ................................. Doing business as REDLINE PLUMBING Estimated workers reported Quarter 3 of Year 2017 "Less than 1 Workers" L&I account contact T1 / IDA HAYNES (360)902-5635 - Email: HAYN235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........................................................ No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni,wa.gov/verify/Detail.aspx?UBI=604125856&LIC=REDLIM*835MM&SAW= 1/12/2018 1...EGEND co PLUMBING FIXTURE Updated: COLD WATER PIPE (CW) -- ---- NOT WATER PIPE (NW) ----- HOT WATER RECIRC PIPE (HWC) —8Ar1— SANITARY PIPE (SAN) - - VENT PIPE (V) —S— STORM PIPE (5) —oRt. RAIN LEADER (RL) 0 RID ROOF DRAIN (RD) 0 GP OVERFLOW DRAIN (OD) FU (Total) GAS PIPE (G) —G — —StM— STEAM PIPE (STM) —CCM— CONDENSATE RTN. PIPE (COND) --F0-1• HOSE BI88/UJALL HYDRANT —'— BALL VALVE —D4— GATE VALE —Dill GATE VALVE w/CAP —011-- BALANCING VALVE ---y'— GAS COCK/VALVE TADA YPE RMT'C GLOBE VALVE 6 LLA ATEOR Y, DAL COL ANGLE GLOBE VALVE 0 3 -WAY MOTORIZED VALVE 0 --A— CONTROL VALVE —14-- CHECK VALVE 4111 PRESSURE RELIEF VALVE —oda— PRESSURE REDUCING VALVE Li" PRESSURE REDUCING STATION 3rd 0 BACKFLOW PREY. STATION 0 —II PIPE CAP —e PIPE BREAK -- PIPE UP —40 1 PIPE DOWN —FD 4th PIPE TEE UP —tot-- 0 PIPE TEE DOWN —let— —11--- PIPE FLANGE —IIF— UNION 11'2" FLEX CONNECTION (PIPE) A«= STRAINER —+— 4 AIR VENT 2.5 PRESSURE GUAGE -- THERMOMETER — — I-IYDRONIC WATER SUPPLY — — HYDRONIC WATER RETURN — — CONDENSER WATER SUPPLY — CONDENSER WATER RETURN - — CHILLED WATER SUPPLY — — CHILLED WATER RETURN JHVAC EQUIPMENT NUMBER/ PLUMBING FIXTURE DESIGNATION General Notes: 1. This project is subject to the 2015 UPC. Plumbing permit is provided by this subcontractor. 2. Waste line cleanout sizing shall be as follows: 4" waste pipe: 4" cleanout with 3W plug. 3" waste pipe: 3" cleanout with 2W plug. 2" waste pipe: 2" cleanout with 11/2" plug. 3. Hot & Cold water piping: - %2" through 11/2" shall be WIRSBO pex & CPVC. - 2" and greater shall be Type L Copper. 4. Hot, cold and recirculation piping will be insulated w/Micro-Lok insulation. Thickness of insulation will be as required by the Seattle Energy Code. 5. Waste & vent piping to be cast iron No -Hub. 6. Maintain one (1) set of clean drawings on site to be marked up for asbuilts, Provide "redline" markups to building Maintenance Department for record. 7. Fixture unit count (WSFU or DFU) for plumbing fixtures are indicated by ()ox) next to the pipe size. cDc—t t r -PER it �l;eci1n;cal EIcc ICal ❑ Pfumhmg Gas Piping City of T U!c ;I Bla s-D';rG DIVISION REVISIONS No changes shall bo made to the 3Copp of work without prior approval of •. Tukwila Building Division. NOTE: Revisions will require a nn'•a plan submittal and may include additional plan rr',,i ;v.r FILE COPY P¢grmit Nog 11- (I) Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of . , • opted code or ordinance. Receipt of approved ' told Co f y and, cctditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 10 201fl City of Tukwila BUILDING DIVISION RECEIVED CITU OF TUKWILA DEC2 Li 2017 PERMIT CENTER RED NE MECHANI AL P.O. BOX 721, Enumclaw, WA 98022 01, 253-939-6398 (o) 206-730-3960(c) SCALE: As Noted CONTRACT NO: DRAWN BY: MTW DATE: 12/23/11 REG. NO. CHECKED BY: Rf"1 Plumbing Tenant Improvement drawings for: Seatac Lighting Foster Building, Tukwila, WA Plumbing Schedules & Symbols P 100 Foster Bdlg Seatac Lighting Plumbing Fixture Calculations Updated: 12/15/2017 SYM QTY SYMBOL DESCRIPTION Number WA/Cold Water Hot Watr Remarks Fixtures FU (EA) FU (Total) FU (EA) FU (Total) FU (EA) FU (Total) GPH (Each) GPH (Total) 4" 2" WC -1/2 Water Closet (1st) 8 4 32 2.5 20 -- -- -- -- TADA YPE RMT'C L-1 6 LLA ATEOR Y, DAL COL 2nd 0 4 0 2.5 0 -- -- -- -- 2" 11% Li" IV" 3rd 0 4 0 2.5 0 -- -- -- -- KS -2 1 SNK, DBL COMPART w/DW CONN ON P -TRAP MAKR001„ 1 4th 0 4 0 2.5 0 -- -- -- -- 11'2" 34" 34" All Others 0 4 0 2.5 0 -- -- -- -- I HOT WATER TANK, ELECTRIC JANITOR RM UR Urinal (1st) 1 2 2 20 20 -- -- -- -- AMTROL ;ST -12 NON -AWE RATED EXP TAMC 1411.1C-1 2nd 1 2 2 15 15 -- -- -- -- INSTA-HOT WATER HEATER BREAKROOM 3rd 0 2 0 10 0 -- -- -- -- 4th 0 2 0 8 0 -- -- -- -- All Others 0 2 0 5 0 -- -- -- -- L-1/2 Lavatory 8 1 8 1 8 1 8 6 48 SH -1/2 Shower 0 2 0 2 0 2 0 30 0 DF Drinking Fountain 1 0.5 0.5 0.5 0.5 -- -- -- -- MS-1 Mop Sink 1 3 3 3 3 3 3 20 20 FD -1/2 Floor Drain 5 2 10 -- -- -- -- -- -- TD-1 Trench Drain 0 4 0 -- -- -- -- -- -- HB-1 Hose Bibb (1st) 1 -- -- 2.5 2.5 -- -- -- -- HB-1/2 Hose Bibb 5 -- -- 1 5 -- -- -- -- S-1/2 Sinks 2 2 4 3 6 3 6 20 40 Totals 61.5 80 17 108 Service Size: 8" Cold Water Service Demand CW HW Tank (HWT) Sizing Based on Table 703.2, an 8" service is rated for 3600 Total Fixture Units: 89 FU's 108 GPH FU's (vertical) & 2640 FU's (horizontal) at 1/4"/L.F. slope. Total GPM required: 40 GPM 0.3 Demand Factor (Office) At 1/8"/L.F. slope, an 8" service is rated for 2112 FU's. Available Pressure (STATIC) @ site: ASSUMED 80 psi 32.4 Total Demand Dynamic Pressure (Static - 20): 60 psi 2 Storage Factor (Office) CW piping shall be sized for a maximum flow of 8 fps. Pressure requred at Fixture: 20 psi 64.8 Total Storage (@ 140F) HW piping shall be sized fro a maximum flow of 5 fps. Pressure loss due to elevation, see calc's: 5 psi Pressure loss in piping & valves, see calc's: 10 psi 17 FU's Domestic Water Service: Pressure loss thru meter & RPBP: 20 psi 15 GPM 1" Service @ 8 FPS = 25 Fixture Units or 18 GPM Total pressure required to serve fixtures: 55 1" Pipe Size 1.5" Service @ 8 FPS = 100 Fixture Units or 45 GPM 1/2" HWC 2" Service @ 8 FPS = 300 Fixture Units or 80 GPM Pressure difference between available vs. losses: 5 psi 4" Service @ 8 FPS = 1750 Fixture Units or 300 GPM 6" Service @ 8 FPS = 8000 Fixture Units or 700 GPM HWT sizing is based on ASHRAE 2015 Applications Chapter 50 Table 10. cDc—t t r -PER it �l;eci1n;cal EIcc ICal ❑ Pfumhmg Gas Piping City of T U!c ;I Bla s-D';rG DIVISION REVISIONS No changes shall bo made to the 3Copp of work without prior approval of •. Tukwila Building Division. NOTE: Revisions will require a nn'•a plan submittal and may include additional plan rr',,i ;v.r FILE COPY P¢grmit Nog 11- (I) Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of . , • opted code or ordinance. Receipt of approved ' told Co f y and, cctditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 10 201fl City of Tukwila BUILDING DIVISION RECEIVED CITU OF TUKWILA DEC2 Li 2017 PERMIT CENTER RED NE MECHANI AL P.O. BOX 721, Enumclaw, WA 98022 01, 253-939-6398 (o) 206-730-3960(c) SCALE: As Noted CONTRACT NO: DRAWN BY: MTW DATE: 12/23/11 REG. NO. CHECKED BY: Rf"1 Plumbing Tenant Improvement drawings for: Seatac Lighting Foster Building, Tukwila, WA Plumbing Schedules & Symbols P 100 NIG P f XTURM SCS SYM QTY FIXTURE LOCATION (1;k1) W V 14W CW SPECIFICATION (SEE SUBMITTALS) WC -I 6 WATER CLOSET FLR MTD, TANK TYPE TOILET RMS 4" 2" 1'2" I.1)C-2 6 OSET, TOILET WS 4" 2" t/z" TADA YPE RMT'C L-1 6 LLA ATEOR Y, DAL COL TOILET WS 2" 11,2" li" !'z" -2 2 LLAC.OVATER YY,t OVAL D ADA TOILET i' 15 2" 11% Li" IV" K5-1 I SINK SINGLE COMPARTMENT SALES 2" 11'2"" �� 1"2" KS -2 1 SNK, DBL COMPART w/DW CONN ON P -TRAP MAKR001„ 1 2" 11'2" 1'2" 1/2" MS -I I MOP SINK FLOOR MOUNTED, 24" x 24" JAN RM 3" 11'2" 34" 34" DF -1 I DRINKING FOUNTAIN ADA APPROVED }•CALL 2" li'znii HWT-1 I HOT WATER TANK, ELECTRIC JANITOR RM 52 GALLON w/(2) 4.5k1.1), 20&/240v -I$ wit 4 P RELIEF 4 FLEX CONNECTIONS ET -I 1 EXPANSION TANK JAN RM AMTROL ;ST -12 NON -AWE RATED EXP TAMC 1411.1C-1 1 14W CIRC PUMP JAN RM 34" 114-1 1 INSTA-HOT WATER HEATER BREAKROOM 1'2" ISE114-110, 4 GAL CAP,150 watts, 120v-10 cDc—t t r -PER it �l;eci1n;cal EIcc ICal ❑ Pfumhmg Gas Piping City of T U!c ;I Bla s-D';rG DIVISION REVISIONS No changes shall bo made to the 3Copp of work without prior approval of •. Tukwila Building Division. NOTE: Revisions will require a nn'•a plan submittal and may include additional plan rr',,i ;v.r FILE COPY P¢grmit Nog 11- (I) Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of . , • opted code or ordinance. Receipt of approved ' told Co f y and, cctditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 10 201fl City of Tukwila BUILDING DIVISION RECEIVED CITU OF TUKWILA DEC2 Li 2017 PERMIT CENTER RED NE MECHANI AL P.O. BOX 721, Enumclaw, WA 98022 01, 253-939-6398 (o) 206-730-3960(c) SCALE: As Noted CONTRACT NO: DRAWN BY: MTW DATE: 12/23/11 REG. NO. CHECKED BY: Rf"1 Plumbing Tenant Improvement drawings for: Seatac Lighting Foster Building, Tukwila, WA Plumbing Schedules & Symbols P 100 L4" VTR (54) t+ 2"V (2) �N) .2111)t } Pk) U.` fU 2"Y 1211 2"V (4) 2"V (10.. t-- 2"Y (12) 4"v (32) 2"V (24414+142"V lb) I N t C- cn N rA ta ID N NILII `1 Ni1 I I 4 I "d' N div fav H 4 I "d' V V V r-oWCO AWCO N B 82116-4 Ljj u- Ank 4" SANITARY SERVICE (54 DPU), STUB OUT 5' BEYOND BLDG WALL FOR CONNECTION TO SITE UTILITES. I.E. _ -56" BELOW SLAB a 1/4" SLOPE A LOADING DOCK 165 STORAGE 166 A — TRAINING/ CONFERENCE ROOM 167 w 2" SAN4 2" SAN (4) 3 F P' )ING CK 0 STORAGE 164 4" SAN (50) a •- 4"W 2"W _0 4_2"W c4-4lw / / 4" SAN 4" SAN (32) a �•r } N WCC A149 a 74' 1"V (82 4a- 2"V (b) ,1-_++4 2"V (2) �. 2"V (2) C4 C•4 IC4I in r 2" SAN\ 3" SAN (6) / / 4" SANT- 4" SAN (12) SANITARY RISER DIAGRAM DIAGRAMMATIC Ili" DOMESTIC WATER SERVICE UP TO "HOT SOX" w/RPPA 4 STUBBED OUT 5' BEYOND BUILDING FOR CONNECTION TO SITE UTILITIES, (CONNECTION BY OTHERS) STORAGE COLLABORATIVE WO LOUNGE BREAKROOM 2 DEISIGNE-'S IF'IC [10 -1:1 ITh El CI LI cJ G cia LP LP LP LP rta FL' Lij LP LP LP LP BATH C OSET EXC BATH 0 0 000 000 EXE 0FIC BATH 1 010 000 2 MAIN OFFICE 34" CW, 344"HW, 34" HWC, 2"V KS -2 ABOVE, SEE ISLAND T� mT 4 P102 FOR CONT 0 g 1 ar --4±1•-4 ,11 7 ''U 'U r rkir a N GAME ROOM 160 4" SAN (2) WAR ROOM 4 155 +t /-*T 2 SAN (2) 2" SAN MOTHER'S ROOM 154 34" CW, 3494, 34" HWC 4 2"V UP, SEE P102 FOR CONTINUATION 4 2"W FOR SINK DETAIL 3"W, 2"V INUATION (MS -1) CLOSET 157 WCO SEE ISLAND SINK DIAGRAM MEN'S RIR 152 WOMEN'S RIR 7'-0" HIGH PARTtTfON 2"W 2"W H la 2" SANITARY (2) SALES OFFICE 2"W UP TO KS -1 000 000 000 000 000 000 000 HALLWAY STORAGE 170 172 A 4.0 Ali► M 2" SAN 3" S BAR 173 ADA R/R 1 152B "W, 2"V WC -2 (TVP) SAMPLING/ WORKROOM 2" SANITARY (2. 174 mr- 414 1111AwI/, 4)..] • vr_• 4"W w/4"V UP 4"W, 2"V1I1C 4 U' (TVP) 1 ADA R/R 151E F.E n 2"W 7 -� _J lc 7 \ 2" SAN4.2),,,, 2" SAN (4) �.�� QCT -cr 4 / I LJ I\ 9/1 LJ SALES TEAM AREA 177 2 -WAY SCO 4" SANITARY SERVICE, 51115 OUT 5' BEYOND BLDG WALL POR _ CONNECTION TO SITE UTILITES. LE. _ -58" BELOW SLAB * 1/4" SLOPE rJ DD 111 DISPLAY 4"W, 2"V WC -1 ( 2"W, 11/2"V PD -1 (TYP fr 2) 2"W HALLWAY 149 WCO IN �2"W w/WGC CLOSET 106 LT 4 COPY/PRINT 1 1 147 TKITC1-EN SINK DISHWASHER CONNECTION fi TO WASTE/VENT RISERS 2" WASTE ISLAND SINK DIAGRAM DIAG RAM MATIC OPEN WORKSTATIONS 144 0 I\1 I/1 y /LJ OPEN MEETING 103 RECEPTION/ LOBBY ADMIN 182 PRIVATE OFFICE 180 101 EN Y CLEANOUT 4 ACCESS COVER. TOP OF COVER TO BE FLUSH 1.11/TOP OF FIN. FLOOR 1/8 C.I. BEND —'''— BALANCE OF PIPING SAME ,45 S.C.O. FLOOR CLEANOUT (F.C.O.) 0 '..tic TRAP SEAL PRIMERS No form of trap that depends for its seal upon the action of movable parts shall be used. Each fixture trap shall have a liquid seal...and shall be protected from freezing. Floor drain or similar traps directly connected to the drainage system and subject to infrequent use shall be protected with a trap seal primer. Trap seal primers shall be directly connected to the water supply and shall be accessible for maintenance. (2015 UPC 1005.0, 1006.0 & 1007.0) BRASS CLEANOUT PLUG W/COUN'T'ER SUNK HEAD. FINISHED GRADE. 16 "SQ. CONCRETE PAD TROWEL SMOOTH 4 EDGE. 1/8 C. 1. BEND C.I. WASTE LINE LENGTH TO SUIT. WASTE 1 -INE. 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE. SURFACE CLEANOUT (S.C.O.) CLEANOUT DETAILS N.T.S. Area of Work 1 11'-2" .fI1�",+� "Liter!✓/Illi tipA A rff.itsATON I.�..emir" t, r-.475 1>-,r9!1 DU r JAN 10 2018 City of Tukwila BUILDING DIVISION Not to Sc LOADING DOCK RECEIVED CITY OF TUKWILI KEY P LAN DEC 2 6 2017 PERMI- CENTER UNDERGROUND PLUMBING PLAN Scale: 1/8" = 1'-0" PROJECT NORTH 0 2' 4' 8' 16' DRAWING SCALE: 1/8" = 1'-0" (UNLESS NOTED OTHERWISE) P.O. BOX 721, Enumclaw, WA 98022 253-939-6398 (o) 206-730-3960(c) SCALE: As Noted CONTRACT NO: DRAWN BY: MTW DATE: 12/23/11 REG. NO. CHECKED BY: RM Plumbing Tenant Improvement drawings for: Seatac Lighting Foster Building, Tukwila, WA Underground Plumbing Plan P 101 '* I 1 SHUT-OFF VALVE, RPDA BACKFLOW PREVENTER 4 STRAINER N NSULATED "HOT 80X" w/1 kW, 120/1 ELECTRIC HEATER 4 t -STAT SET FOR FREEZE PROTECTION. COORDINATE w/E.C. FOR ELECTRICAL SERVICE 4 DISCONNECT SWITCH. PROVIDE w/12" DEEP GRAVEL BASE FOR DRAINAGE. RPDA DEVICE 4 "HOT BOX" SHALL BE PER CITY OF TUKWILA STANDARDS. II IIIIII Iir:10 �.•._..,..r� III I I I -III 1-141 L1 H -II --III I I 1-71 1 1 1 11'2" DOMESTIC WATER SERVICE 1 1 1 1 1 1 1 1= STUBBED OUT 5' BEYOND BUILDNG FOR CONNECTION TO SITE UTILITIES, (CONNECTION BY OTHERS) STORAGE 164 11'2" CW (93) 11'2" CW (61) - 4 Iii-- - 1" CW (12) 34" 144CW 1------f' (3) Zt— IT COLLABORATIVE WORK/LOUNGE 11'2" DOMESTIC WATER SERVICEN "HOT 80X" w/RPPA, SEE DIAD THIS SHEET 163 344" 144CW (3) 1" H4CW (16 WSFU) 34" 144CW 1'2" 1-14CW (3) (1) 1'2" 144CW (2) 11'2" CW (b5) 1"HW(10) 34" HW (6) 34" CW (4) -1=I- ---11. 34_1 HW (S) 1 1 1'2" CW (2) 11 1 1 DOMESTIC WATER RISER DIAGRAM DIAGRAMMATIC BREAKROOM 162 GAME ROOM 160 WAR ROOM MOTHER'S ROOM L 154 1'2" CW (25) TYYP ALL WC'S MEN'S R/R 152 WOMEN'S RIR 151 1" CW (20) OPEN WORKSTATIONS 144 1" CW (15) SERVER/ STORAGE 141 V2" 144CU1 (2) 1'2"I.14CW 1'2"CW (1) (05) PRIVP OFFI( 140 LOADING DOCK 165 STORAGE 166 TRAINING/ CONFERENCE ROOM 167 STORAGE DESIGNE :' J 3ATH C_OSET 114 DW 1'2" DOMEStfc uJ4 TER 0 75FFICE '� ' %'` r 1 - ��i L C---- uftL l9J-,Li ---_ 1 L� 34" CW, 34 "1-11U, 34" HWC 4 2"V DN TO UNDERFLOOR 4 CONT TO KS -2 SW, SEE P101 FOR CON`NUATION 000 000 000 000 000 000 000 EXC BATH BATH CJ 1 CJ FT Fr ErL on on pan 00o 000 opo ono HALLWAY 172 IN FFICE SALES OFFICE L 4_ 2"V (2) (SHOUN FOR LOCATE N J4 SEE -D1 11'2 "CW (62) ARITY T)— 11'2 "DOMESTIC CW Dist -SEE DIAD T1415 SHT 4 514T P101 FOR CONTINUATION COPY/PRINT 147 .0.3.3 HIGH TITION 2"V (2) (TYP OF 3) HALLWAY SAMPLING/ WORKROOM LN SALES TEAM AREA 1 177 1 _1— DISPLAY PLUMBING PLAN N 1'2" 1-14CW ON TO LAYS CLOSET (TYP OF 3) 106 1'2" 144CW, 2"V's DN TO FIXT'S Scale: 1/8" = 1'-O" d 0 J Yh P, 0 L rA [1) JJ r ran In LOCAN OF SKYLIC ABOVE OPEN WORKSTATIONS 115 U u - r7 I/I V_ J 7 M OPEN MEETING 103 RECEPTION/ LOBBY 101 WAR ROOM 110 ENTRY WAR R011)M 111 01 COLLAE COMBNATION TEMPERATURE/ PRESSURE RELIEF VALVE. §O THERMOMETER UJ4TE' 14E4TE: Po. HW - SIZE PER PLANS CW - SIZE 6 11 PER PLANS HWG - SIZE PER PLANS 140T WATER CIRCULATION PUMP 1/6 14P, 120/1 ELEC w/24 HR TIMER SIESMIC RESTRAINTS AS REQUIRED SY UPC 4 LOCAL CODES. (TYPICAL) rile._ EXPANSION TANK INSULATION BASE AS REQUIRED BY UPC 4 LOCAL CODES. (TYPICAL) L_J MEZZANINE FINISHED FLOOR WATER HEATER PIPING DIAGRAM N.T.S. Area of Work r -v 10050 .1IiOia.., r r+l .r EXISTING ROCKE WALL 3-4 H RECEIVED KEY PLAN CITY nFfTta1�'dvlLA, EEC 6 2017 CE v1 -ER Not to Sc PROJECT NORTH 0 2' 4' 8' 16' DRAWING SCALE: 1/8" = 1'-0" (UNLESS NOTED OTHERWISE) REDLINE MECHA ICAL P.O. BOX 721, Enumclaw, WA 98022 253-939-6398 (o) 206-730-3960(c) SCALE: As Noted CONTRACT NO: DRAWN BY: MTW DATE: 12/23/11 REG. NO. CHECKED BY: RM Plumbing Tenant Improvement drawings for: Seatac Lighting Foster Building, Tukwila, WA Plumbing Plan P 102