HomeMy WebLinkAboutPermit EL17-0309 - TUKWILA SCHOOL DISTRICT - TRANSPORTATION BUILDINGELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION LIGHTING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. INDICATES ISOLATED GROUND. EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. EQUIPMENT CONNECTION SPECIAL EQUIP CONNECTION WITH LIQUID TIGHT FLEX TO MATCH EQUIPMENT LOW -VOLTAGE WIRING MOTOR CONNECTION CONDUIT CONCEALED IN WALL OR CEILING SPACE ONLY CONDUIT UNDER GROUND OR FLOOR EXISTING CONDUIT UNDERGROUND DEMO CONDUIT UNDERGROUND CONDUIT UP CONDUIT DOWN NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH COMBINATION FUSED DISCONNECT/MAGNETIC STARTER MANUAL MOTOR STARTER WITH OVERLOAD PROTECTION ELECTRICAL CONTACTOR, TYPE AS INDICATED SINGLE PUSH BUTTON CONDUIT STUB OUT WITH PLASTIC BUSHING 0 SPD BRANCH CIRCUIT HOME RUN (3/4"C, #12 CONDUCTORS AND #12 GND, UNO) GROUNDING ELECTRODE PER CODES FLEXIBLE CONDUIT CODE SIZED JUNCTION BOX WITH COVER PLATE SURGE PROTECTIVE DEVICE CORD REEL WITH 4PLEX OUTLET 0 4 PUSH BUTTON SWITCH TO MATCH EQUIPMENT STARTER AND CONTROLLER FAP RED EMERGENCY SHUT-OFF PUSH BUTTON FIRE ALARM PANEL FIRE ALARM ANNUNCIATOR FIRE ALARM SMOKE DETECTOR FIRE ALARM SMOKE DETECTOR, DUCT TYPE 41) CEILING RECEPTACLE FIRE ALARM HEAT DETECTOR, RATE -OF -RISE TYPE oA 41( ELECTRICAL DEVICE AS INDICATED, A=ABOVE COUNTER DUPLEX RECEPTACLE DUPLEX RECEPTACLE, TAMPER RESISTANT TYPE TWO DUPLEX RECEPTACLES IN COMMON BACK BOX AND UNDER COMMON PLATE, TAMPER RESISTANT TYPE TWO DUPLEX RECEPTACLES IN COMMON BACK BOX AND UNDER COMMON PLATE SINGLE RECEPTACLE F O H FIRE ALARM HEAT DETECTOR, FIXED TEMPERATURE TYPE FIRE ALARM SMOKE DETECTOR, PROJECTION BEAM TYPE FIRE ALARM CONNECTION, TYPE AS NOTED ON PLANS TAMPER SWITCH FIRE ALARM MONITORING CONNECTION FLOW SWITCH FIRE ALARM MONITORING CONNECTION FIRE ALARM AUDIO-VISUAL SPEAKER/STROBE STAGE LIGHTING CONTROL RECEPTACLE A FIRE ALARM STROBE LIGHT dVdb • EL 9 0 FLUSH FLOOR BOX WITH DEVICES AS INDICATED DUPLEX RECEPTACLE GFCI TYPE SPECIAL RECEPTACLE TYPE TO MATCH EQUIP SERVED, VERIFY REQUIREMENTS MULTI -GANG FLOOR BOX WITH DEVICES AS NOTED ON PLANS WITH 1"C.O. SPARE TO ADJACENT CEILING SPACE. SURFACE METAL RACEWAY WITH DEVICES AS INDICATED. PROVIDE COMPLETE DEVICES, FITTINGS AND ASSEMBLIES. OC. SPACING OF DEVICES ARE AS NOTED ON PLANS. LIGHT FIXTURE, SEE SCHEDULE FOR TYPE LIGHT FIXTURE, WITH 'EL' INDICATES WITH EMERGENCY BATTERY PACK LIGHT FIXTURE, SEE SCHEDULE FOR TYPE WALL MOUNTED LIGHT FIXTURE, SEE SCHEDULE FOR TYPE LIGHT FIXTURE, SEE SCHEDULE FOR TYPE EXIT LIGHT WITH EMERGENCY DRIVER TYPICAL LIGHTING FIXTURE DESIGNATION, SEE SCHEDULE FOR TYPE ra REX FIRE ALARM MANUAL PULL STATION, D=DUAL ACTION TYPE. FIRE ALARM DOOR RELEASE CONNECTION FIRE ALARM KNOX BOX PER FIRE MARSHAL REQUIREMENTS FIRE ALARM' COMBINATION FIRE/SMOKE DAMPER CEILING MOUNT FIRE ALARM AUDIO-VISUAL SPEAKER/STROBE BELL/BUZZER POST INDICATOR VALVE FIRE ALARM CONNECTION SECURITY SYSTEM MOTION DETECTOR SECURITY SYSTEM CEILING MOUNT MOTION DETECTOR 360' SECURITY SYSTEM CONTACT (D = DOOR, W = WINDOW) SECURITY SYSTEM KEY PAD SECURITY SYSTEM CARD READER ELECTRIC STRIKE REQUEST TO EXIT SENSOR SINGLE POLE SWITCH SECURITY SYSTEM CAMERA LOCATION THREE WAY SWITCH (4 = 4 -WAY SWITCH) LOW VOLTAGE SWITCH (LD = LV SWITCH WITH DIMMING CONTROL) MOMENTARY CONTACT SWITCH PILOT LIGHTED SWITCH KEY OPERATED SWITCH MANUAL DIMMER SWITCH IC DD OCCUPANCY SENSOR WITH PUSHBUTTON ON/OFF SWITCH ADM N7 S WP LOCK DOWN BUTTON (SECURITY/INTERCOM CONNECTIONS) INTERCOM CONSOLE INTERCOM DIGITAL DISPLAY INTERCOM CALL SWITCH INTERCOM HANDSET, ADM=ADMIN TYPE WITH DISPLAY D=DESK TYPE INTERCOM WALL OR CEILING SPEAKER INTERCOM WEATHERPROOF OUTDOOR HORN/SPEAKER VACANCY SENSOR SWITCH (VD = VS SWITCH W/ 0-10V DIMMING CTRL) MC MASTER CLOCK CEILING MOUNTED PHOTO CELL/PHOTO SENSOR LIGHTING CONTROL OCCUPANCY SENSOR DUAL TECHNOLOGY (WALL MOUNT) LIGHTING CONTROL OCCUPANCY SENSOR DUAL TECHNOLOGY (CEILING MOUNT) LIGHTING CONTROL SYSTEM POWER PACK LIGHTING CONTROL SYSTEM ROOM CONTROLLER SWITCHED RECEPTACLE CONTROLLER (CONTROL VIA LTG CTRL SYSTEM DEVICES) CEI ANALOG CLOCK DIGITAL CLOCK ANALOG CLOCK/SPEAKER COMBINATION DIGITAL CLOCK/SPEAKER COMBINATION VOLUME CONTROL VIDEO PROJECTOR OUTLET THERMOSTAT TELECOMMUNICATIONS - OUTLET DEVICE (UTP RJ45 UNLESS OTHERWISE NOTED) # = NUMBER INSIDE SYMBOL INDICATES THE QUANTITY OF TELECOMMUNICATION CABLE DROPS AND JACKS AT EACH OUTLET LOCATION. (I.E. 1,2,3, ETC.) A ADJACENT TO SYMBOL = MOUNT ABOVE COUNTER (REFER TO ARCH CASEWORK) WAP ADJACENT TO SYMBOL = CEILING MTD WIRELESS ACCESS POINT TELECOM CONNECTION CCN ADJACENT TO SYMBOL = CLOSED CIRCUIT TV TELECOM CONNECTION TELECOMMUNICATIONS - FLOOR OUTLET DEVICE (UTP RJ45 UNLESS OTHERWISE NOTED) # = NUMBER INSIDE SYMBOL INDICATES THE QUANTITY OF TELECOMMUNICATION CABLE DROPS AND JACKS AT EACH OUTLET LOCATION. (I.E. 1,2,3, ETC.) HDML AV OUTLET (LOW) ADJACENT TELECOM OUTLET AMP SOUND SYSTEM AMPLIFIER SOUND SYSTEM SPEAKER MICROPHONE JACK SOUND SYSTEM AUXILIARY INPUT TV OUTLET TELEVISION AUDIO-VISUAL INPUT JACK HDMI GROMMET PLATE (HIGH) ADJACENT WALL PROJECTOR ABBREVIATIONS ABBRV DESCRIPTION ABBRV DESCRIPTION ABBRV DESCRIPTION A, AMP AMPERE G, GND GROUND ACP ACCESSIBLE CARD PATH GC, G.C. GENERAL CONTRACTOR P PHASE, POLE PB PUSHBUTTON ADA AMERICAN DISABILITY ACT GFCI GROUND FAULT CIRCUIT INTERRUPTER PNL PANEL, PANELBOARD AFC AFF ATS AL BKR C CKT CO AVAILABLE FAULT CURRENT ABOVE FINISHED FLOOR AUTOMATIC TRANSFER SWITCH ALUMINUM BREAKER CONDUIT CIRCUIT CONDUIT AND PULL WIRE ONLY GFP HH. IDF LCP LTG LTS LV GROUND FAULT PROTECTION HANDHOLE INTERMEDIATE DISTRIBUTION FRAME LIGHTING CONTROL CENTER LIGHTING LIGHTS LOW -VOLTAGE PRI PS PSE PV (R) RCPT REF PRIMARY POWER SUPPLY, PROJECTION SCREEN PUGET SOUND ENERGY PHOTOVOLTAIC REVISED RECEPTACLE REFERENCE, REFRIGERATOR MB MAIN BREAKER REX REQUEST -TO -EXIT COMM CTRL CU DLZ (E) EC, E.C. EF COMMUNICATION CONTROL COPPER DAYLIGHT ZONE EXISTING ELECTRICAL CONTRACTOR EXHAUST FAN MC, M.C. MDF MDP MECH MH MLO MR MECHANICAL CONTRACTOR MAIN DISTRIBUTION FRAME MAIN DISTRIBUTION PANEL MECHANICAL MANHOLE MAIN LUGS ONLY MOTOR RATED SWITCH SEC SECONDARY SPD SOW SPECS SS SW TEL SURGE PROTECTION DEVICE SCOPE OF WORK SPECIFICATIONS STAINLESS STEEL SWITCH TELEPHONE ELEC ELECTRICAL (N) NEW TC TELECOMMUNICATION EM EQPT (F) F FA FAAP FACP EMERGENCY EQUIPMENT FUTURE FURNACE, FAHRENHEIT FIRE ALARM FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM CONTROL PANEL N NEC OC OFCI OFOI OL NEUTRAL NATIONAL ELECTRICAL CODE ON CENTER OWNER -FURNISHED, CONTRACTOR -INSTALLED OWNER -FURNISHED, OWNER -INSTALLED OVERLOAD THRU (TYP) UNO W WH WP......... XFMR THROUGH TYPICAL UNLESS NOTED OTHERWISE WIRE WATER HEATER WEATHERPROOF TRANSFORMER APPLIANCES KEY LETTER E.C. TO PROVIDE RECEPTACLE FOR APPLIANCE AS SHOWN. VERIFY LOCATION WITH ARCHITECT. CM : COFFEE MAKER CP : COPIER DW : DISHWASHER DY : DRYER FZR : FREEZER GD : GARBAGE DISPOSAL. H/HD : HAND OR HAIR DRYER IH : INSTANT HOT WATER HEATER IM : ICE MAKER MW : MICROWAVE REF : REFRIGERATOR RG : RANGE RH : RANGE HOOD VM : VENDING MACHINE WH : WASHER SEPARATE PERMIT REQUIRED FOR. Egigethaelcal 0 Electrical 'Plumbing %els Plphv City of Tukwila BUILDING DIVISION, No changes �SIQNg of �a, g shell be a to thq SOQpn ork Without prior approval of Tukwila Building Division, i`0 s R:r4Si0113 Will require a new an s and may include additional plan r viow QsItt01 Permit Con .a.„17,011.94 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION GENERAL REQUIREMENTS ALL SHEETS 1. E.C. TO PROVIDE ALL MATERIAL AND LABOR . FOR MAINTAINING FIRE RATING OF WALLS IN AREAS WHERE ELECTRICAL DEVICES PENETRATE IN OR THROUGH. SEE ARCHITECTURAL DRAWING FOR FIRE WALL LOCATION. 2. E.C. TO PROVIDE ELECTRICAL CONNECTION FOR ALL FAN SPEED SWITCHES.. COORDINATE LOCATION AND CONNECTIONS WITH M.C. 3. SEE ARCHITECTURAL DRAWING FOR LOCATION OF ELECTRICAL DEVICES LOCATED ON EXTERIOR OF BUILDING. ALL EXTERIOR BUILDING MOUNTED DEVICES (EXCEPT FIRE ALARM DEVICES) SHALL HAVE FACTORY FINISH OR PAINT TO MATCH BUILDING SURFACE. 4. ALL FLUSH MOUNT EQUIPMENT, CABINET AND PANEL BOARD SHALL HAVE FACTORY TYPE FLUSH MOUNT TRIM KIT FOR COMPLETE INSTALLATION. 5. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ALTERNATE BID NUMBERS AND CORRESPONDING AREAS AND RELATED ELECTRICAL WORK TO BE PROVIDED. E.C. TO INCLUDE IN BASE BID, ALL ELECTRICAL WORK THAT IS REQUIRED FOR BASE BID AND IN THE ASSOCIATED AREAS OF CONSTRUCTION IF ANY OF THE ALTERNATE BIDS ARE TAKEN OR ACCEPTED. 6. REFER TO PLANS FOR LOCATION OF EMERGENCY LIGHTING BATTERY PACK AND FIXTURES. 7. PROVIDE COMPLETE WORK FOR REQUIREMENTS AS DESCRIBED ON LEGEND. 8. E.C. TO VERIFY WITH CABINET INSTALLER FOR ALL CABINET LOCATIONS, DIMENSIONS AND COUNTER HEIGHTS PRIOR TO OUTLET ROUGH -IN. OUTLETS LOCATED ABOVE COUNTER ARE TO BE INSTALLED TO CENTER LINE ABOVE COUNTER TOP OF BACK SPLASH. AS DIRECTED OR INDICATED IN SPECIFICATIONS. VERIFY HEIGHT WITH ARCH/ENG. OF ANY LOCATION THAT WILL NOT ACCOMMODATE MOUNTING HEIGHT. 9. ALL EXTERIOR EQUIPMENT, PANELS OR DEVICES SHALL BE WEATHERPROOF AND WITH NEMA -3R ENCLOSURE TYPE. 10. ELECTRICAL CONTRACTOR TO VERIFY WITH SERVING UTILITY COMPANIES FOR ALL UTILITY CHARGES AND TO INCLUDE SUCH CHARGES IN BID. 11. CIRCUITS, WIRE SIZE AND WIRE HASH MARKS ARE SHOWN FOR CIRCUIT CLARITY, BUT MAY NOT NECESSARILY REPRESENT THE COMPLETE WIRING COUNTS AND MINIMUM SIZES FOR CONNECTING THE CIRCUITS SHOWN. E.C. TO INCLUDE IN THE BID, ALL THE REQUIRED WIRING SIZES AND NUMBER OF CONDUCTORS IN ORDER TO INSTALL ALL CIRCUITS SHOWN AS NECESSARY. 12. ALL LIGHT SWITCHES SHALL BE LOCATED AT STRIKE SIDE OF DOOR SWING. REFER TO ARCHITECTURAL FLOOR PLANS FOR DOOR LOCATIONS. SWITCHES THAT CAN NOT BE LOCATED ON STRIKE SIDE OF DOOR BECAUSE OF STRUCTURAL MEMBERS SHALL BE AS DIRECTED IN FIELD. 13. DO NOT INSTALL ANY FLUSH WALL OUTLET BACK TO BACK. A MINIMUM OF 24" SEPARATION IS REQUIRED BETWEEN ANY OUTLET INSTALLED ON FIRE RATED WALL. 14. INSTALLATION OF NEW UNDERGROUND FEEDERS SERVING POWER, INTERCOM, TELEPHONE, FIRE ALARM, AND T.V. SHALL INCLUDE CUTTING, PATCHING, HAND DIGGING, ETC. DO NOT CUT OR DAMAGE ANY EXISTING UTILITIES, STRUCTURAL MEMBERS OR BUILDING FOUNDATIONS. VERIFY ROUTE AND REMOVE ALL EXISTING FLOOR TILE IN AREAS THAT ARE TO BE CUT. ANY DAMAGE TO EXISTING UTILITIES OR BUILDING STRUCTURE SHALL BE REPAIRED TO OWNER'S SATISFACTION AT THE CONTRACTORS EXPENSE. FIELD VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO WORK. 15. ALL ONE LINES, RISERS, AND CONDUIT ROUTING ARE SCHEMATICS AND ARE NOT SHOWING EXACT PHYSICAL ARRANGEMENT OF EQUIPMENT. WHERE INDICATED ON DRAWINGS ALL JUNCTION BOXES AND PULL BOXES ARE MINIMUM REQUIREMENTS. ELECTRICAL CONTRACTOR TO PROVIDE ALL OTHER FITTINGS AND PULL. BOXES OF ADEQUATE SIZE IN THE RACEWAY SYSTEM WHEREVER NECESSARY OR REQUIRED BY NATIONAL ELECTRICAL CODE. PROVIDE EXPANSION JOINT FITTINGS FOR CONDUITS PASSING THROUGH NEW OR EXISTING EXPANSION JOINTS INSTALLED BETWEEN BUILDINGS. VERIFY EXACT LOCATIONS AND DETAILS OF EXPANSION JOINTS PRIOR TO WORK. COORDINATE ALL CONDUIT ROUTING, PULL BOX AND EQUIPMENT LOCATIONS WITH OTHER TRADES TO AVOID CONFLICTS OF EQUIPMENT INSTALLATIONS. ALL EMPTY CONDUITS SHALL HAVE PULL WIRES. 16. E.C. TO PROVIDE 60 WATT LAMPS FOR ALL RANGE HOODS. 17. NO ELECTRICAL CONDUITS ARE ALLOWED TO BE RUN IN ANY FLOOR SLABS. CONDUITS SERVING DEVICE LOCATED IN FLOOR SHALL BE SERVED FROM BELOW AND PASS THROUGH THE FLOOR SLAB. 18. ALL FEEDERS AND BRANCH CIRCUITS SHALL BE ROUTED IN . CONDUIT. 19. EXTERIOR CONDUIT UNDERGROUND SHALL BE SCHED 40 PVC WITH RIGID GALVANIZED STEEL FACTORY -RADIUS ELBOWS AND ABOVE GROUND EXTERIOR CONDUIT SHALL BE RIGID GALVANIZED STEEL. INTERIOR CONDUIT SHALL BE EMT, UNLESS NOTED OTHERWISE. GENERAL NOTES IN AREAS WHERE ROOF STRUCTURE/DECKING IS EXPOSED E.C. SHALL PROVIDE ALTERNATE MEANS FOR DEVICE ATTACHMENT. E.C. SHALL PROVIDE UNISTRUT OR OTHER APPROVED METHODS FOR ATTACHMENT BETWEEN TRUSSES OR BEAMS. IN NO CASE SHALL ANY DEVICE BE MOUNTED ON THE EXPOSED UNDERSIDE OF THE ROOF DECK WITHOUT. PRIOR APPROVAL FROM THE ARCH/MANUFACTURER. ALL SUPPORT ITEMS SHALL BE PAINTED TO MATCH SURROUNDING SURFACE. ALL MEANS OF SUPPORT/ATTACHMENT SHALL BE APPROVED BY THE ARCH. REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC MAY 0 5 2017 J. w City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 5 2017 PERMIT CENTER ELECTRICAL SHEET LIST. TE0.01 TE0.02 TE0.03 TE1.01 TE2.01 TE3.01 ELECTRICAL LEGEND AND NOTES MECHANICAL EQUIPMENT SCHEDULES WSEC ENERGY CODE FORMS ELECTRICAL SITE PLAN POWER FLOOR PLAN SYSTEMS FLOOR PLAN TE5.01 TE7.01 TE8.01 ELECTRICAL ONE -LINE AND PANEL SCHEDS LIGHTING FLOOR PLAN ELECTRICAL DIAGRAMS AND DETAILS TE8.02 ELECTRICAL DIAGRAMS AND DETAILS rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com V 0 OJ O _� Um (OZ U0 J CO 0 E - ©C 0 J O- - to Z REVISION DATE Design: SKF Drawn: BT Checked: FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/14/2017 Drawing Title ELECTRICAL LEGEND AND NOTES Drawing Number TE0.01 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC TB LEGEND AND NOTES.DWG 0 w 1-- Q co N ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT (NOTE 1) MECHANICAL UNIT NO. VOLTS/PHASE LOAD (A/W/HP) MCA (A) DISCONNECT CONDUIT WIRE CFM NOTES FRAME (A) FUSE (A) HEAT PUMPS HP -01 240/1 20.3 A 20.3 A 30 30 1" 3#10, #10G -- .1,2 HP -02 240/1 20.3 A 20.3 A 30 30 1" 3#10, #10G -- 1,2 FAN COIL UNITS FC -01 240/1 87.3 A 87.3 A NOTE 7 100 NOTE 7 1-1/2" 3#1, #8G 1,330 1,4 FC -02 240/1 87.3 A 87.3 A NOTE 7 100 NOTE 7 1-1/2" 3#1, #8G 1,330 1,4 EXHAUST FANS EF -109 120/1 1.7 A 2.1 A MR -SW -- 3/4" 2#12, #12G 110 1,4 EF -110 120/1 1.7 A 2.1 A MR -SW -- 3/4" 2#12, #12G 110 1,4 EF -111 120/1 1.7 A 2.1 A MR -SW -- 3/4" 2#12, #12G 110 1,4 EF -112 120/1 1.7 A 2.1 A MR -SW -- 3/4" 2#12, #12G 110 1,4 ELECTRIC WALL HEATERS EWH-01 120/1 750 W 6.3 A MR -SW -- 3/4" 2#12, #12G -- 1,4,8 EWH-02 240/1 3 KW 14.5 A MR -SW -- 3/4" 2#12, #12G -- 1,4,8 DOMESTIC WATER HEATER DWH-01 240/1 9 KW 54.1 A 60 -- 1" 3#4, #10G -- 1 PUMPS DCP-01 120/1 1/8 HP 4.4 A MR -SW -- 3/4" 2#12, #12G -- 1,4 NOTES: 1.) REFER TO POWER PLANS FOR CIRCUIT NUMBER. 2.) PROVIDE WEATHERPROOF NEMA -3R DISCONNECT AND MOUNT ON WALL ADJACENT TO MECH UNIT. 3.) PROVIDE WEATHERPROOF NEMA -3R DISCONNECT AND MOUNT NEXT TO MECH UNIT. PROVIDE UNISTRUT RACK AND MOUNT DISCONNECT TO RACK. 4.) PROVIDE MOTOR -RATED SWITCH FOR DISCONNECT. 5.) PROVIDE DUCT SMOKE DETECTOR(S) AS REQUIRED. COORDINATE WITH FIRE ALARM CONTRACTOR AND MECHANICAL CONTRACTOR. 6.) INDOOR AC UNIT POWERED FROM OUTDOOR AC UNIT. LABEL MOTOR -RATED DISCONNECT SWITCH "POWER SUPPLY FROM OUTDOOR UNIT AC-##". 7.) UTILIZE CIRCUIT BREAKER AS DISCONNECT. CIRCUIT BREAKER IS IN SAME ROOM AS MECH UNIT: 8.) THERMOSTAT PROVIDED BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE CONNECTIONS. COORDINATE WITH MECHANICAL. REVIEWED .FOR COMPLIANCE WITH NPPA 70 - NEC MAY 052017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 5 2017 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 MIEMMIM TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com J Z ZE5CD � 0— _5 Um �z UO mQ a_ IL < 0 .I 0- _ to Z co >- 2 2 w co 62 W z 0 REVISION DATE Design: SKF Drawn: BT Checked: FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/14/2017 Drawing Title MECHANICAL EQUIPMENT SCHEDULES Drawing Number TE0.02 TB MECHANICAL EQUIPMENT SCHEDULES.DWG COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC cq 0 w 2 r` 1- N Lighting Summary Lighting �� .trij,£".k-�ii.ri.. , Motor,$ }� p2`,"tr and Electrical Permit�Checklist'P 3� LTG -CHK Project Title: Tukwila Public Schools -Transportation Building IDate 3/16/2017 The follow ing Washington State information is necessary to checka permit application for compliance w nth the lighting, motor, and electrical Energy Code, Commercial Provisions. requirements in the Applicability (yes,no,na) (Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Lighting controls, general Yes 0405.4.1 C405.4.1 0405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's ratedwatts per fixture; TE7.01 Luminaire level lighting controls (LLLC) Identify spaces eligible for lighting pow er exemption on plans and in compliance forms; indicate the exception applied; TE7.01 RIH Identify lighting equipment eligible for lighting pow er exemption in fixture schedule and in compliance forms; indicate the exception applied; NA Lighting in dw elling units Indicate that exenpt lighting equipment is in addition to general area lighting and is controlled independently NA R2/R2E Yes C405.3 Exit signs Indicate location of exit signs on plans and rated w atts per fixture in lighting fixture schedule (maximum 5 w atts per fixture) TE7.01 S NA C405.1 Lighting in dw elling units -lamp efficacy if high efficacy exception is applied to permanently installed lighting fixtures in dw elling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy larrps in project (min 75% to comply w ith exception). TE7.01 T2 NA C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project w ah dw elling units, to comply w ith additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per w att or more. Calculate percentage of fixtures w ith lamps that have this efficacy rating (min 95% to comply w ith option). TE7.01 X (EXEMPT EXIT SIGN) Yes Lighting Power Calculation - Indicate compliance path taken shut-off control Yes C405.4.2.1 Building Area Method Complete required compliance forms - proposed w attage per building area does not exceed maximum allow ed w attage per building area. Identify locations of building areas on plans TE0.02-TB).03 NA 0405.4.2.2 Space -By -Space Method Complete required compliance forms - total proposed w attage does not exceed maximum allow ed w attage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable 0405.2.1 C405.2.1.1 Occupancy sensor controls NA C406.3 Reduced lighting pow er density To comply w ith additional efficiency package option, demonstrate in compliance forms that total connected interior lighting w attage is 75% less than the total maximum allow ed lighting w attage via Building Area IVthod or Space -By -Space Method 0405.2.1.2 Occupancy sensor controls - w arehouses EXTERIOR LIGHTING POWER & EFFICACY Yes C405.5.2 Total connected exterior lighting pow er Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated w atts per fixture; TE7.01 Identify exterior applications eligible for lighting pow er exemption on plans and in compliance forms; indicate exception applied; NA Automatic time sw itch controls Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Yes Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AFIJ TB0.02 NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 w atts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per w att) in fixture schedule NA NA Lighting, C405.5.2 ,,. tet)�f r.. Motor �tr�mtes Exterior lighting power calculations Yt;4i'€ U7,,.;7 ty,.„s`f; andand Electrical Complete required compliance form- proposed w attage for exterior lighting plus base site allow ed does not exceed maximum allow ed { ., .; �t f;Y`:r Permit Check is t,; Pg .4 fir,r LTG -CHK H, K, Project Title: Tukwila Public Schools - Transportation Building Date 3/16/2017 The follow ing Washington information is necessary to checka permit application for compliance ith the lighting, motor, and electrical State Energy Code, Commercial Provisions. requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS & TRANSFORMERS NA 0405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken NA NA C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dw elling unit in Group R-2 has a separate electrical energy meter Naarea NA C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied ,: ,} Lighting �i htin NA 0405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per w att; LTG-CHK LTG CHK. Project Title: Tukwila Public Schools - Transportation Building Indicate rated w atts per cfm for elevator cab ventilation fans do not exceed 0.33 w alts per cfm; 3/16/2017 The follow ing information is necessary to checka permit application for compliance w ith the lighting, motor, and electrical requirements in Washington State Energy Code, Commercial Provisions. Indicate automatic controls that de -energize lighting and ventilation fans w hen elevator is stopped and unoocupied for a period of 15 minutes or more Applicability (yes,no,na) Code Section NA C405.9.2 Escalators and wing w alks Indicate escalators comply w ith ASMEA17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted w hen not in use NA 0405.2.5 - Item 3 NA 0405.9.3 Regenerative drive Indicate all one -w ay dow n or reversible escalators are provided w ith a variable frequency regenerative drive NA 0405.2.5 - Item 4 Yes C405.10 Controlled receptacles Identify all controlled and uncontrolled receptables on electrical plans in each space in w hich they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; TE2.01 & TE7.01 0405.2.5 - Item 5 Indicate on plans w hether the method of automatic control for each controlled receptable zone is by occupant sensor or progranrnable tine -of -day control TE2.01 & TE3.01 If "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist n s 1 fe Motor Lighting c�2,;£nk.$ llsMPg 1TG CHK. aandElectrical Permit Che Project Title: Tukwila Public Schools - Transportation Building I Date 3/16/2017 The follow ing information is Washington State Energy Code, necessary to checka permit application for compliance w ith the lighting, motor, and electrical requirements in the Commercial Provisions. AYplicability es,no,na) I Code Section Component mP Compliance information required in permit documents q I Location in Documents I Building Department Notes LIGHTING CONTROLS Office Building Yes 0405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken T�.01 R1F/R1FE NA C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided w ith LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters TE7.01 RIH NA 0405.1 Lighting in dw elling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance w ith high efficacy exception 7E7.01 R2/R2E Yes C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (w hether combined w ith occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifics application it serves TE2.01 S Yes C405.2.2•1 C405.2.2.2 C405.2.3 Manual interior lighting controls Indicate on plans w hich method of manual 50% lighting load reduction is provided, or w hether lighting load is reduced via occupancy sensors or daylight responsive controls TE7.01 T2 8 C4°5.2.2 Method of automatic Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time sw itch) for all lighting zones; TE7.01 X (EXEMPT EXIT SIGN) Yes shut-off control Indicate locations w here automatic shutoff is provided by other methods (occupancy sensor or digital timer sw itch) or w hich time sw itch control exception applies TE7.01 Indicate on plans the spaces served by occupancy sensors; TE7.01 Yes 0405.2.1 C405.2.1.1 Occupancy sensor controls Indicate w hether occupancy sensor controls are configured to be manual -on, automatic 50% -on, or serve a space eligible for automatic 100% -on per exception TET.01 NA 0405.2.1.2 Occupancy sensor controls - w arehouses Indicate aislew ays and open areas in warehouse spaces provided w ith occupancy sensor controls that reduce lighting pow er by 50% NA C405.2.6 Digital timer sw itch Indicate required digital timer sw itch control function w hen control is used NA C405.2.2.1 Automatic time sw itch controls Indicate locations of override sw itches on plans and the lighting zone(s) served, include area sq. ft. Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; TE7.01 C405.2.4.2 Indicate toplight daylight zone areas on plans, include sq. ft: NA YesFor C405.2.4.3 Daylight zones - Sidelight and toplight small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) w here daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) NA Indicate on plans lighting zone(s) served by daylight T�.01 responsive controls; Daylight responsive Identify sidelight and toplight daylight zones that are not provided w ith daylight sensing controls and the exception(s) NA that apply; Yes 0405.2.4 controls Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least Ti7.01 two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone TE7.01 NA C405.2.5 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section Naarea C405.2.5 - Items 1 &2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general lighting and other lighting applications w ithin the same space; ,: ,} Lighting �i htin s ,, ty ;Motor t, �l„....} and Electrical Indicate manual and automatic lighting control method r�,.l a5 Permit checklist lYP 2 2 t LTG-CHK LTG CHK. Project Title: Tukwila Public Schools - Transportation Building Date 3/16/2017 The follow ing information is necessary to checka permit application for compliance w ith the lighting, motor, and electrical requirements in Washington State Energy Code, Commercial Provisions. the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NA 0405.2.5 - Item 3 HoteVmotel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and sw itched receptacles in guest room NA 0405.2.5 - Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighting NA 0405.2.5 - Item 5 Lighting for non- visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications w ithin the same space; Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications w ithin the sane space; p Indicate method of manual lighting control and applicable automatic lighting control Yes C405.2.5 - item 7 Means of egress lighting g Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; TE7.01 Provide calculation of lighting power density of total egress lighting; BATTERY BACKED NA If total egress lighting g g g pow er density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut- off during unoccupied periods; Indicate method of automatic shut-off control TE7.01 Yes 0405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; NA For building fagade and landscape lighting, indicate automatic controls shut off lighting as a function of daw n/dusk and fixed opening/closing time; NA For all other exterior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting pow er by at least 30% betw een 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon notion sensor TE7.01 NA C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 w atts, indicate on plans w hether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 NA C405.2.5 Area controls - Master control sw itches and circus pow er limit Indicate location(s) of master control sw itch(es) intended to control multiple independent sw aches; circuit breaker may not be used as a master control sw itch; Verify that no 20 amp circuit controlled by a single sw itch or automatic control is loaded beyond 80% NA 0406.4 Enhanced digital lighting controls To comply w ith additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided w ith continuous dimming, or exception taken; Include calculation of percent total installed interior lighting pow er that is configured w ith required enhanced lighting control functions (min 90% to comply w ith additional efficiency package option) NA 0405.13 0408.3 Lighting system functional testing If claiming lighting system commissioning exemption provide supporting calculation; D(9NPT, < 20KW Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; provide w ritten procedures for functional testing of all automatic controls and describe the expected system response } }� Yt r Interior Li Intim Building Area Method TG INT BLD` Project title: Tukwila Public Schools - Transportation Building Date 3/16/2017 Fixture Description NOTE 2, 3, 4, 5 For Building Department Use Gear Maximum Allowed Lighting Wattage NOTE 1 Building Area Location (plan#, room #, or ALL) Area Description Gross interior Area in ft2 Allow ed Watts per ft2 Watts Allow ed (w atts/ft2 x area) Office ALL Office Building 2535 0.66 1674 Office TE7.01 R1F/R1FE 6 29 174 Office TE7.01 RIH 4 43 172 Office 7E7.01 R2/R2E 6 37 222 Office TE7.01 S 1 70 70 Office TE7.01 T2 8 27 216 Office TE7.01 X (EXEMPT EXIT SIGN) 4 Total 2535 Proposed Lighting Wattage Building Area Location (plan #, room #) Fixture Description NOTE 2, 3, 4, 5 Number of Fixtures Watts per Fixture NOTE6 Watts Proposed Office TE7.01 D6/D6E 4 19 76 Office 7E7.01 P4/P4E 18 29 522 Office TE7.01 R1F/R1FE 6 29 174 Office TE7.01 RIH 4 43 172 Office 7E7.01 R2/R2E 6 37 222 Office TE7.01 S 1 70 70 Office TE7.01 T2 8 27 216 Office TE7.01 X (EXEMPT EXIT SIGN) 4 Compliance by Building Area NOTE' Building Area Warnings Total Allow ed Watts Total Proposed Watts interior Lighting Pow er Allow ance Office Building Grounds Applies to luminaires> 100 Watts 1674 1452 COMPLIES Tradable Maximum Allowed Lighting Wattage NOTE 1 Base Site Allow ance: 750 Tradable Surfaces Surface Description Area (ft2), perimeter (If) or # of Rens Allowed Watts per ft2 or per If Allowed Watts • x ft2 (or x if) Main Entry Door ENTRY DOORS (2) 6 ExterioryLighting LTG -EXT Project Title: Tukwila Public Schools -Transportation Building Date 3/16/2017 Exterior Lighting Zone Table C405.5.2(1) Specifiedbyjurisdiclion. Zone 1 Zone 2 Zone 3 Clear Zone selection requiredto enable LTG -EXT form For Building Department Use • Building Grounds Applies to luminaires> 100 Watts Efficacy >80 lumens/w att Exemption Controlled by motion sensor 41 82 Tradable Maximum Allowed Lighting Wattage NOTE 1 Base Site Allow ance: 750 Tradable Surfaces Surface Description Area (ft2), perimeter (If) or # of Rens Allowed Watts per ft2 or per If Allowed Watts • x ft2 (or x if) Main Entry Door ENTRY DOORS (2) 6 30W/LF door 180 Other Entry Door ELEC RM DOOR& STORAGE 7 20W/LF door 140 Grounds Walkways <10 wide RAMP/WALKWAY 40 0.8 W/LF 32 Total Allow ed Tradable + Site Allow ance Watts: 1102 Tradable Proposed Lighting Wattage NOTE2 Tradable Surface Fixture Description NOTE 3,4 Number of Fixtures Watts per Fixture NOTES Watts Proposed. Main Entr/ Door WE 2 41 82 Other Enty Door WE 2 41 82 Grounds Walkw ays <10 wide WE 1 41 41 Total proposed tradable watts maynotexceedthe sum of total allowed tradable watts plus' the base site allowance. Any b ase site allowance not needed to make tradable naffs comply can be applied to individual non -tradable categories. Total Proposed Tradable Watts: 205 Non Tradable Maximum Allowed Lighting Wattage NOTE 1 Site Allow ance Remaining: 750 Non -Tradable Surfaces Surface Description Area (ft2), perimeter (If) or # of items Allow ed Watts per ft2 or per If Allow ed Watts x ft2 (or x If) Permanently installed interior lighting fixtures in dwelling units complywfth: Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commerical provisions. Exterior Lighting System Description Brieflydescribe exteriorlighting system type and features. LED WALL MOUNTED FIXTURES. ALL EXTERIOR FIXTURES HAVE INTEGRAL PHOTOCELLS. Non -Tradable Proposed Lighting Wattage NOTE 2 Non -Tradable Surface Fixture Description NOTE 3, 4 Number of Fixtures Watts per Fixture NOTE 5 Watts Proposed Interior Lighting Controls All C405.2.1 - C405.2.8 Controls C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls perC406.4. Permanently installed interior lighting fixtures in dwelling units complywfth: Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commerical provisions. Exterior Lighting System Description Brieflydescribe exteriorlighting system type and features. LED WALL MOUNTED FIXTURES. ALL EXTERIOR FIXTURES HAVE INTEGRAL PHOTOCELLS. Non -tradable proposed watts maynot exceed allowed watts for any individual surface tnless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Non -Tradable Watts Exceeding LPA: 0 Remaining Site Allow ance: 750 Exterior Lighting COMPLIES WITH MAX. ALLOWANCE LGT-SUM' Project Info Compliance formsdo not require a password to use. instructional and calculating cells are write - protected. Project Title: Tukwila Public Schools -Transportation Building Date 3/16/2017 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. Company Name: Tukwila School District Company Address: 4640 S 144th St. Applicant Name: Scott Felton Applicant Phone: 253-472-3300 Applicant Email: skf@treswest.com For Building Department Use Project Description New Building Addition Alteration Plans Included Include PROJ-SUM form (included in envelope forms workbook) with lighting complliance forms. Building Additions Referto Section C502.2.6 for additional requirements. Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply w ith all applicable provisions as a stand alone new construction project Lighting systems in addition are combined w ith existing building lighting systems to demonstrate compliance Additioniscombinedwith existing: For interiorlightingprojects, include new+existing interior lighting fixture wattage in Proposed Lighting Wattage table in LTG -INT -BLD or LTG- NTSPACEform. For exterior lighting projects, include new+ existing exteriorlighting fixture wattage in Proposed Tradable and Proposed Non -Tradable L'ghting Wattage tables in LTG -ECT form. Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. ifprojectincludesa combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more ofthe fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit maybe combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lightingcontrols shall be commissioned per C408.3. No changes are being made to the interiororexteriorlighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced Less than 50% of existing are replaced Lamp and/or ballast replacement only - existing total w attage not increased 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -WT -BLD, LTG-INT-SPACEorLTG-EXT form. Less than 50% replaced - Total lighting power of new+ existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new+ existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG-INT-SPACEor LTG -ECT form. 50% threshold applies to numb er of luminaires for interiorspaces and parking garages, and total installed wattage for exterior luminaires. Lighting Controls Interior lighting Parking garage Exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) New or moved lighting panel Interior space is reconfigured - luminaires unchanged or relocated only New wi ring or circuit- For interior lighting, provide required manual controls per C4052.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exteriorlighting, provide required controls per C405.2.7. New or moved panel- Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interiorspace-Provide all required lighting controls that applyto a new interior space. Application specific lightingcontrol provisionsper C405.2.5 do not applyto reconfigured spaces. Change of Space Use Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405•4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-iNT-BLD or LTG -INT -SPACE form. Lighting Summary, cont. LGT-SUM Project Title: Tukwila Public Schools - Transportation Building Date • 3/16/2017 Interior Lighting System Description Brieflydescribe interiorlighting system type and features. LED LIGHT FIXTURES WITH LOCAL OCCUPANCY SENSING CONTROLS FOR AUTOMATIC SHUTOFF. DAYLIGHT SENSORS AND DAYLIGHT HARVESTING T CONTROLS FOR DAYLIGHT AREAS. BATTERY BACKED EGRESS LIGHT FIXTURES. Interior Lighting Power Allowance Method Building Area Method Space -by -space Method Select method used in project. Interior Lighting Controls All C405.2.1 - C405.2.8 Controls C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls perC406.4. Permanently installed interior lighting fixtures in dwelling units complywfth: Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commerical provisions. Exterior Lighting System Description Brieflydescribe exteriorlighting system type and features. LED WALL MOUNTED FIXTURES. ALL EXTERIOR FIXTURES HAVE INTEGRAL PHOTOCELLS. EL VT REVIEWED FOR COMPLIANCE WITH NFPA 70 A NEC MAY 0 5 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 5 2017 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com tY w 0 0 0J 0 0 1••-- "" "" O) N. �- Wr 1-- _ REVISION DATE Design: SKF Drawn: BT Checked: FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/14/2017 Drawing Title WSEC ENERGY CODE FORMS Drawing Number TE0.03 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC TE0.03 TB WSEC ENERGY CODE FORMS.DWG ti 0 N N PLAN NOTES 16 EXISTING CIRCUIT CONDUCTORS FOR EXISTING 240V 1–PHASE LIGHTS SHALL REMAIN AND BE EXTENDED TO AND LOCATED IN NEW HANDHOLE UPON DEMO OF EXISTING PEDESTAL. PROVIDE NEW CIRCUIT WITH 1"C, 3#8(2H+N), #8G FROM. NEW MDP PANEL IN MECH/ELEC ROOM TO THIS HANDHOLE AND RECONNECT EXISTING LIGHTS POWER CONDUCTORS. PROVIDE ALL RACEWAY, CONDUCTORS, AND CONNECTIONS AS REQUIRED FOR COMPLETE OPERATION. 17 240/120V CIRCUIT, 2H+1 N+1 G. ROUTE UNDERGROUND. 18 PROVIDE UNDERGROUND CONDUIT, CABLING, AND CONNECTIONS TO FROM FIRE ALARM PANEL IN MECH/ELEC ROOM TO SPRINKLER PIV. PROVIDE FIRE ALARM ADDRESSABLE POINT MODULES AS REQUIRED BY AHJ AND LOCAL CODES. COORDINATE WITH CIVIL. 19 PROVIDE FIRE ALARM KNOX BOX AND MOUNT TO EXISTING FENCE. COORDINATE LOCATION WITH ARCHITECT AND AHJ. 20 PROVIDE SPARE EMPTY HANDHOLE FOR FUTURE CCTV AND ACCESS CONTROL CABLE ROUTING. 21 PROVIDE SPARE 2" EMPTY CONDUIT WITH PULL–STRING. EXISTING SCL POLE AND POLE MOUNTED XFMR—i EXISTING SCL–/ HANDHOLE PLAN NOTES 11 GATE CONTROLLER SHALL BE ACTIVATED AND OPEN GATE UPON FOB WIRELESS SIGNAL. PROVIDE PROGRAMMING AND SETUP AS REQUIRED FOR COMPLETE OPERATION. COORDINATE WITH OWNER. 12 13 14 15 PROVIDE A 1" CONDUIT SLEEVE FROM GATE CONTROLLER UNDERGROUND TO TRAFFIC TRIP WIRE CABLE. SCL SHALL REMOVE EXISTING POLE MOUNTED TRANSFORMER AND INSTALL NEW MOUNTED TRANSFORMER. COORDINATE WITH SCL. PROVIDE 4"C, 3-600KCM, #2/0 GROUND. DEMO EXISTING SERVICE CONDUIT AND CONDUCTORS FROM POLE MOUNTED TRANSFORMER TO EXISTING PEDESTAL. PROVIDE NEW SERVICE CONDUIT AND CONDUCTORS PER NOTE #14. WORK SHALL BE PERFORMED IN EASEMENT. COORDINATE WITH SCL. ELECTRICAL SITE PLAN PLAN NOTES 0 NEW 4" COMMUNICATIONS SERVICE ENTRANCE CONDUIT FROM SERVING UTILITY, CENTURYLINK, TO DEMARC IN STORAGE ROOM. COORDINATE WITH CENTURYLINK. 06 NEW UNDERGROUND UTILITY SERVICE CONDUIT AND CONDUCTORS FROM POLE MOUNTED UTILITY TRANSFORMER TO CT CABINET, VIA HANDHOLES, ON OUTSIDE OF BLDG.. O7 PROVIDE 400A, 240/120V 1–PHASE SERVICE CT CABINET AND ASSOCIATED METER AND MOUNT TO EXTERIOR BUILDING WALL. COORDINATE WITH SCL. 08 MAIN ELECTRICAL PANEL LOCATED DIRECTLY BEHIND CT CABINET INSIDE MAIN ELECTRICAL ROOM. PANEL SHALL BE SERVICE–ENTRANCE RATED, 400A, 240/120V 1–PHASE WITH A 400A MAIN BREAKER. O9 COMMUNICATIONS DEMARC LOCATED IN STORAGE ROOM. 10 PROVIDE POWER TO MOTORIZED GATE. ROUTE CONDUIT AND WIRING UNDERGROUND TO SERVING PANEL IN NEW BUILDING. 0 PLAN NOTES 0 EXISTING LIGHT POLE AND FIXTURE TO REMAIN. FIXTURE IS A SINGLE HEAD FIXTURE ON A 30FT POLE WITH CONCRETE BASE. PROVIDE NEW LAMP IN FIXTURE. O2 EXISTING LIGHT POLE AND FIXTURE TO BE RELOCATED. CAREFULLY EXCAVATE CONDUITS AND RE–ROUTE TO NEW FIXTURE LOCATION. REMOVE EXISTING WIRING BACK TO NEXT ACTIVE LIGHT POLE ON CIRCUIT AND PROVIDE NEW CIRCUIT WIRING BETWEEN EXISTING LIGHT POLES TO REMAIN AND THIS RELOCATED FIXTURE. 0 RELOCATE EXISTING LIGHT POLE AND FIXTURE TO THIS LOCATION. PROVIDE NEW POLE BASE, CONDUIT WIRING AND CONNECTIONS FOR COMPLETE OPERATION. PROVIDE NEW LAMP IN FIXTURE. 04 EXISTING PEDESTAL, SCL UTILITY METER# 415415 AND LOAD CENTER WITH BREAKERS TO BE DISCONNECTED AND REMOVED. PROVIDE NEW HAND HOLE FOR NEW UNDERGROUND SERVICE FEEDER AND SITE LIGHTING CIRCUITS. EXTEND RACEWAY AND CONDUCTORS AS REQUIRED AND MAKE CONNECTIONS. 'C,3#10,#10 •U EXISTING HOUSE • SOUTH 128TH STREET REET 1"C 3#10,#10G 40 0:62::.__....._:..._ 55,57 _ I p MDP -59,61 6' CHAN UNK fl '3#10,#10G 17 Ix I x 4,57 it Ix j 1 O� Ix MECH%LEC RO 140 I L.- -- NEW TRq,FFIC OUT 146 -- X GA -T1 7 j 0" IN 40 2" GENERAL NOTES 1. COORDINATE EXISTING ELECTRICAL SERVICE TO BE DISCONNECTED AND REMOVED AND NEW ELECTRICAL SERVICE TO BE INSTALLED WITH SEATTLE CITY LIGHT (SCL). PROVIDE ALL RACEWAY, CONDUCTORS, HANDHOLES, CT CABINET AND ASSOCIATED EQUIPMENT AS REQUIRED BY SCL. 2. COORDINATE NEW TELECOM SERVICE WITH CENTURYLINK. PROVIDE ALL RACEWAY, CONDUCTORS, HANDHOLES AND ASSOCIATED EQUIPMENT AS REQUIRED BY CENTURYLINK. 3. ALL NEW CONDUIT SHALL BE INSTALLED UNDERGROUND BY MEANS OF DIRECTIONAL BORING. CONTRACTOR SHALL BE REQUIRED TO HIRE QUALIFIED DIRECTIONAL BORING CONTRACTOR WITH MINIMUM 5–YEARS EXPERIENCE PERFORMING DIRECTIONAL BORING. PROVIDE QUALIFICATION LETTER DESCRIBING COMPLIANCE WITH THIS REQUIREMENT DURING SUBMITTALS. r U6" -1'11-11-111 _'''''Nr1) 2" n U6" &y1 CLQ 0 NEW I TRANSPORTATION - BUILDING MDP STORAGE RM 106 0 (i --- X--X---.._X^_.X� x -X- RATED HANDHOLE L ECH/ELEC ROOM 6' CHAN UNK EXISTING SHED TO BE REMOVED. X— .x —X 55 57 x_._X--r CENTUR+ --- LINK CABINET U8"X2 EXISTING CENTURYLINK-' POLE AND COMM CABINET • ON\ SCALE : 1" = 20'-0" • r L� 45 stj REVIEWED �� COMPLIANCEH NPPA 70 ©NEC MAY 0 5 2017 City of Tukwila BUILDING DIVISION RECEIVED CITU OF TUKWILA APR 2 5 2017 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 issotvv TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com J Z E3 J O I 5 0 co Ci z v�= J ~ o Q O _1 o <z 00 (0 o" Q c F - F2 w O REVISION DATE Design: SKF Drawn: BT Checked: FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/14/2017 Drawing Title ELECTRICAL SITE PLAN Drawing Number TE1.01 TE1.01_TB_ELECTRICAL SITE PLAN.DWG ti CV N r COPYRIGHT m 2015 ROLLUDA ARCHITECTS INC ( A ) IRRIGATIO CONTROLLER 1"C, 2#1o, #10G N MD MR HAND DRYER,- -- MDP-4T ) , 11 0 — • • - • I i WOMEN I I I 111 ( B.7 ) DP -24 MDP -26,28 MDP -9 ELECTRICAL UTILITY METER ELECTRICAL SERVICE UTILITY CT CABINET DFL2of/IEEL ECCH 0 107 SPD MDP Hi GENERAL NOTES 1. REFER TO ELECTRICAL SCHEDULE FOR MECHANICAL EQUIPMENT, SHEET TE0.02, FOR MECHANICAL EQUIPMENT DISCONNECT SIZE, RACEWAY/CONDUCTOR SIZES, CIRCUITING INFORMATION AND ADDITIONAL REQUIREMENTS. PLAN NOTES 0 CT CABINET AND METER. 0 MOUNT RECEPTACLE FOR VIDEO PROJECTOR 12" BELOW CEILING. COORDINATE WITH ARCHITECT. • NEMA 14-30 RECEPTACLE FOR DRYER. • PROVIDE INTEGRAL FACTORY LOCKOUT BREAKER IN PANELBOARD. BREAKER SHALL BE USED AS DISCONNECT. • CONNECT EXHAUST FAN TO LIGHTING CIRCUIT IN ROOM. EXHAUST FAN SHALL BE SWITCHED ON/OFF WITH LIGHTS. 0 PROVIDE GFCI CIRCUIT BREAKER. • NEMA 14-50R RECEPTACLE FOR RANGE. 0 14/2 MC CABLE FROM RANGE HOOD J—BOX ON MOUNTING PLATE TO RANGE POWER DISCONNECT BOX. ROUTE CONCEALED IN WALL AND MARK WITH BLACK TAPE. PROVIDE CONNECTIONS FOR COMPLETE OPERATION. REMOTE MOUNTED SURGE PROTECTIVE DEVICE. MOUNT ON EITHER SIDE OF MDP PANELBOARD. CONDUCTORS TO. SPD SHALL MAX 18" IN LENGTH. SO ROUTE CONDUIT UNDERGROUND TO MDP PANELBOARD. • TO CONTROLLED OUTLET OF EACH DUPLEX RECEPTACLE WITHIN THIS ROOM AND ON THIS SAME CIRCUIT ONLY. REFER TO DETAIL, SHEET TE8.01, FOR CONTROLLED RECEPTACLES SWITCH DETAIL. 4) MDP -53 SHOW (2) +42" CUSTODIA CLST. 109 / 111 +42" STORAGE MDP -41 • , '112 [ +42" HAND DRYER DRIVER PREP - - DY 1 3#10,#10G MDP -30 ST RAG MDP -32,341 106 MDP-38 MDP -50 •11 fl ••.-. -• . • I.1 MDP -56 ALARM_PANEL___ ACCESS' CONTROL PAIIIELi r ( 3 ) SECURITY PANEL 1 / 1 1 i 1 • , MDP -419 ---1 1 >.(4) STACKED DUPLEX OUTLETS / 1 A A A 1 MDP -15 PUNCH -IN CLOCK MDP -29 VIDEO PROJECTO 1 MDP -40 MDP -i42 A MDP -44,46 1"C,3#6,#10G MDP -48 MDP -37 s2 (0411 414 MDP -19 MDP -31 40' MDP -17 A MDP -39 MDP -63,65 WP MDP -64,66 ADA PB 3.6"D I ---- ------ AAI AUTOMATICOPAT6D\ I LOBBY 101 MDP -51 CONFERENCE / TRAIN NG 104 BREAK ROOM 105 MDP -21 MDP -23 OFFICE 103 OVIDEO PROJECTOR ADA PB +36" OFFICE SMART PROJECTOR F102 +84" POWER FLOOR PLAN SCALE : 1/4" = 1'-0" SMART PROJECTOR +84" i II I \ 1 F-----" I 1 Li• -.77.7...,==:: 7,...=7.:::-..=::::= ::.?.... . 1 2.7) ••••••4\ 1 ) REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC MAY 0 5 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 5 2017 PERMIT CENTER rolluda architects architecture planning interior cies gn 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 fTh.‘ TRES WEST 0t ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com Z 0 E5 O —I 0m CI)z O 0 (111 < a. Et F - wz0 REVISION DATE Design: SKF Drawn: BT Checked: FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/14/2017 Drawing Title POWER FLOOR PLAN Drawing Number TE2.01 TE2.01 _TB -POWER FLOOR PLAN.DWG r--- Cs.1 COPYRIGHT CO 2015 ROLLUDA ARCHITECTS INC r A,/ f.Bi i; B. ELECTRICAL POWER EQUIPMENT SPACE (C) ir i CUSTODIAN CLST. 1 109 CiTCiM 107- J 106 SECURITY PANEL GENERAL NOTES 1. REFER TO SHEETS TE8.01 AND TE8.02 FOR COMMUNICATIONS, ACCESS CONTROLS, SECURITY SYSTEM, AND FIRE ALARM SYSTEM DETAILS AND DIAGRAMS. 2. REFER TO SITE PLAN, SHEET TE1.01, FOR LOCATION OF PIV AND FIRE ALARM REQUIREMENTS. PLAN NOTES O 24"X6" FREE-STANDING DATA RACK. O PROVIDE 4'x8'x3/4" FIRE RATED PLYWOOD BACKBOARD MOUNTED VERTICALLY ON WALLS AS SHOWN. PAINT ALL PLYWOOD WHITE. THE BOTTOM EDGE OF THE BACKBOARD SHALL BE 6" ABOVE FINISHED FLOOR. 03 PROVIDE (2) 2" CONDUIT SLEEVES, (1) SHALL BE USED FOR THIS PROJECT, AND (1) SHALL BE SPARE FOR FUTURE. 0 PROVIDE ALL FIRE ALARM ADDRESSABLE POINT MODULES AND CONNECTIONS FOR SPRINKLER DEVICES AS REQUIRED BY AHJ AND LOCAL CODE. PROVIDE HUBBELL RACO LARGE CAPACITY #260 SERIES BOX RECESSED IN WALL, WITH #835 RAISED OPEN COVERPLATE, AND BUSHING FOR CABLE PROTECTION. PROVIDE 2" CONDUIT WITH PULL -STRING FROM LOW AV BOX TO HIGH AV BOX FOR OWNER FURNISHED AV CABLE ROUTING. 06 MOUNT HIGH AV BOX 12" BELOW CEILING. COORDINATE WITH ARCHITECT. FIRE -ALARM -PANEL----_.. I[ 4) i 108 PUNCH—IN CLOCK •a© ACP 0r• DE WAP e •c 105 KP LOBBY 101 CONFERENCE / TRAINING ADA 104 WAP FRONT DOOR BUZZER., •-0 ADA PB 6" OFFICE +84" HIGH AV LOW AVO PUSH BUTTON BUZZER ()HIGH AV (DLOW AV W cc WP SYSTEMS FLOOR PLAN SCALE : 1/4" = 1'-0" CLI` REVIEWED .FCR COMPLIANCE WITH NFPA 70 NEC MAY 0 5 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 5 2017 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 UMMINNM 11.4 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com z a OJ I 5 - 0 m z 0Q_ F1-- Et < O -' - m Z00 _I 0- Q 2 co W z 0 REVISION DATE Design: SKF Drawn: BT Checked: FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/14/2017 Drawing Title SYSTEMS FLOOR PLAN Drawing Number TE3.01 TE3.01 TB-SYSTEMS FLOOR PLAN.DWG 1- N 1- O N N v - car COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC SERVING UTILITY 2 CONNECTION POINT 57,300 EXTERIOR WALL GRADE NEMA -3R 400A CT CABINET INTERIOR WALL MDP 240/ 120V 400A MCB PROVIDE WIREWAY •24" MAX ABOVE PANEL FOR ROUTING OF BRANCH CIRCUIT HOMERUNS WITH LARGER SLEEVE CONDUITS BETWEEN PANEL AND WIREWAY. 3/4"C, 3#10, #10 GROUND d ISPD SINGLE-PHASE SERVICE ENTRANCE RATED. 6,883 "C, 3-600KCM, #2/0 GROUND XX,XXX 3-600KCM, #2/0 GROUND = CALCULATED AVAILABLE FAULT CURRENT POWER ONE -LINE DIAGRAM SCALE: NONE PANEL DP LOCATION: SERVING: FED FROM: MECH/ELEC RM 240/120 VOLT 400 AMP BUS RATING SCCR: 22,000 A 1 PHASE 400 AMP MAIN BREAKER AFC: 6,883 A 3 WIRE MOUNTING: SURFACE BUILDING SCL POLE MOUNTED XFMR CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P. KVA TYPE LOAD DESCRIPTION CKT 1 LTS - CORR., STOR., EQPT RMs, RRs L 0.830 20/1 A 30/2 - 0.000 - D - SPD (SURGE PROTECTIVE DEVICE) (EXTERNAL TO PANELBOARD) 2 3 LTS - CONF RM, BREAK RM, OFFICES L 0.696 20/1 B 4 5 LTS - EXTERIOR WALL PACKS L 0.205 20/1 A 100/2 - 16.656 - H - FAN COIL (FC -01) - - 6 7 RCPT - ELEC RM / EXTERIOR S R 0.720 20/1 B 8 9 RCPT- STOR., CUST., BREAK, CORR. R 1.260 20/1 A 100/2 - 16.656 - H - FAN COIL (FC -02) - 10 11 RCPT - SHOWER RM, RESTROOMS R 0.720 20/1 B 12 13 RCPT-ABVCTR DRIVER PREP R 0.720 20/1 A 20/1 - S SPARE. 14 15 RCPT - ABV CTR DRIVER PREP R 0.720 20/1 B 20/1 - S SPARE 16 17 RCPT -COPIER (LOBBY) D 0.800 20/1 A 20/1 0.750 H ELECTRIC WALL HEATER (EWH-01) 18 19 RCPT - LOBBY/LOBBY DESK R 0.720 20/1 B 20/2 - 3.000 - H - ELECTRIC WALL HEATER (EWH-02) (STORAGE RM 106) 20 21 RCPT - OFFICE 102 R 0.900 20/1 A 22 23 RCPT- OFFICES 102, 103 R 1.080 20/1 B 15/1 0.422 M DOMESTIC CIRC PUMP (JANITOR 109) 24 25 RCPT - OFFICE 103 R 0.900 20/1 A L60/2 - 9.000 - WH - DOMESTIC WATER HEATER (9KW) (CUSTODIAN CLST. 109) 26 27 RCPT- VIDEO PROJ (OFFICES) D 0.600 20/1 B 28 29 RCPT - VIDEO PROJ (BRK & CONF RM) D 0.600 20/1 A 20/1 0.800 D WASHING MACHINE (CUSTODIAN 109) 30 31 RCPT - CONF RM SOUTH R 0.600 20/1 B 30/2 -- 5.000 D - DRYER (CUSTODIAN 109) - 32 33 RCPT- BREAK RM/CONF RM NORTH R 0.720 20/1 A 34 35 RCPT - ABV CTR (BREAK RM) R 0.540 20/1 B 20/1 0.800 D REFRIGERATOR (BREAK RM) 36 37 RCPT-ABVCTR (BREAK RM) R 0.360 20/1 A 20/1 0.500 D DISHWASHER (BREAK RM) 38 39 RCPT - BREAK WEST, EXTERIOR W R 1.080 20/1 B 20/1 0.696 D GARBAGE DISPOSAL (BREAK RM) 40 41 RCPT- LOBBY, STOR. 113, EXTER. S R 0.720 20/1 A 20/1 1.200 D MICROWAVE (BREAK RM) 42 43 SPARE S - 20/1 B 50/2 - 8.000 - D - RANGE (BREAK RM) - 44 45 SPARE S - 20/1 A 46 47 HAND DRYER (WOMEN'S RR 111) H 0.600 G20/1 B 20/1 0.500 M RANGE HOOD (BREAK RM) 48 49 HAND DRYER (MEN'S RR 112) H 0.600 020/1 A 20/1 0.250 D FIRE ALARM CONTROL PANEL 50 51 ADA DOOR POWER (DOOR 101) D 0.500 20/1 B 20/1 0.250 D ACCESS CONTROL PANEL 52 53 COMM RACK (STORAGE 106) D 0.500 20/1 A 20/1 0.250 D SECURITY PANEL 54 55 SITE POLE LIGHTS (NOTES 1, 2) (EXTERIOR SITE) L - 1.500 - 20/2 - B 20/1 0.050 D FIRE SMOKE DAMPERS 56 57 A 20/1 0.250 D IRRIGATION CONTROL 58 59 EAST GATE (OUTGOING) POWER (EXTERIOR SITE) M - 0.800 - 20/2 - B 20/2 0.800 - M - WEST GATE (OUTGOING) POWER (EXTERIOR SITE) 60 61 A - 62 63 HEAT PUMP (HP -01) (EXTERIOR SHED) M -- 3.960 30/2 - B 30/2 3.960 - M - HEAT PUMP (HP -02) (EXTERIOR SHED) 64 65 A - 66 PHASE LOAD PHASE A= 47.78 KVA PHASE B= 45.96 KVA LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD 3.23 11.76 10.44 38.26 9.00 21.05 3.96 93.74 KVA 390.59 AMP CALC. LOAD 4.04 10.88 10.44 38.26 9.00 21.05 0.99 94.66 KVA 394.41 AMP REQUIRED SERVICE -ENTRANCE RATED HINGED DOOR -IN -DOOR TRIM OPTIONS: NOTES: L = LISTED LOCKOUT CIRCUIT BREAKER G = GFCI CIRCUIT BREAKER 1.) PROVIDE NEW CIRCUIT AND CONDUCTORS TO NEW HANDHOLE AND CONNECT TO EXISTING POLE LIGHT CONDUCTORS. 2.) REFER TO SITE PLAN FOR NEW HANDHOLE LOCATION. I opkiiPwPn FO L 1'1 COMPLIANCE WITH NFPA 70 NEC MAY 0 5 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 5 2017 PERMIT CENTER rolluda architects architecture planning ulterior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 v v- TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com V z 0 V rr= 5 ♦0 W VJ Z UD H CO Q L.1.. O J 0- Z w 0 v_ 12 (1) 0 .1 0 0 0 C/) 4640 S 144TH ST. co (0 co J F- 0 CJ) -J 0 0 00 1- M CI) cp J F- REVISION DATE Design: SKF Drawn: BT Checked: FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/14/2017 Drawing Title ELECTRICAL ONE -LINE AND PANEL SCHEDS Drawing Number TE5.01 COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC TB- ELECTRICAL ONE -LINE AND PANEL SCHEDS.DWG 2 ti N N LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION MANUFACTURER LIGHT SOURCE INPUT WATTS NOTES NAME CATALOG NUMBER QTY. TYPE */ LUMENS CCT (K) D6 6" DOWNLIGHT. 1500 LUMENS. SELF -FLANGED. MEDIUM DISTRIBUTION. CLEAR APERTURE, SEMI -SPECULAR FINISH. GOTHAM EVO-40/15-6AR-MD-LSS-120-EZ10 INC LED IL / 1,572 4K 19 1,2,3 D6E 6" DOWNLIGHT. 1500 LUMENS. SELF -FLANGED. MEDIUM DISTRIBUTION. CLEAR APERTURE, SEMI -SPECULAR FINISH. EMERGENCY BATTERY. GOTHAM EVO-40/15-6AR-MD-LSS-120-EZ10-EL INC LED IL / 1,572 4K 19 1,2,3,4 P4 4FT LINEAR 0-10V DIMMABLE TO 1% LED UP/DOWN PENDANT FIXTURE. HIGH OUTPUT. 20%UP/80%DOWN. SIGNAL WHITE FINISH. DUST COVER. SLOPED CEILING. FLAT ENDCAP. FINELITE SERIES 16 LED ID-DCO-4'-2E-H-840-10U90D-120V- SC -FA -FE -TEAR INC LED IL / 3,565 4K 44 1,2,3,5 P4E 4FT LINEAR 0-10V DIMMABLE TO 1% LED UP/DOWN PENDANT FIXTURE. HIGH OUTPUT. 20%UP/80%DOWN. SIGNAL WHITE FINISH. DUST COVER.. SLOPED CEILING. FLAT ENDCAP. INTEGRAL EMERGENCY BATTERY. FINELITE SERIES 16 LED ID-DCO-4'-2E-H-840-10U90D-120V- SC-FA-FE-TBAR-EM INC LED IL / 3,565 4K 44 1,2,3,4,5 R1 F 1' X 4' RECESSED FLANGED 0-10V DIMMABLE LED FIXTURE. STANDARD LIGHT OUTPUT. FLAT LENS. DIFFUSE CENTER. MATTE WHITE. DRYWALL KIT. FINELITE HPR LED -F -1X4 -DCO -S -840 -120V -SC -DW INC LED IL / 3,099 3.5K 29 1,2,3 RIFE 1' X 4' RECESSED FLANGED 0-10V DIMMABLE LED FIXTURE. STANDARD LIGHT OUTPUT. FLAT LENS. DIFFUSE CENTER. MATTE WHITE. DRYWALL KIT. EMERGENCY BATTERY. FINELITE HPR LED -F -1X4 -DCO -S -840 -120V -SC -DW INC LED IL / 3,099 3.5K 29 1,2,3,4 R1 H 1' X 4' RECESSED 0-1 OV DIMMABLE LED FIXTURE. HIGH LIGHT OUTPUT. ANGLED LENS. DIFFUSE CENTER. MATTE WHITE. FINEUTE HPR LED -A -1X4 -DCO -H -840 -120V -SC -(NOTE 5) INC LED IL / 4,653 4K 43 1,2,3 2' X 2' RECESSED 0-10V DIMMABLE LED FIXTURE. BOOSTED STANDARD LIGHT OUTPUT. ANGLED LENS. DIFFUSE CENTER. MATTE WHITE. FINELITE HPR LED -A -2X2 -DCO -B -840 -120V -SC -(NOTE 5) INC LED IL / 4,507 4K 37 1,2,3 R2E 2' X 2' RECESSED 0-10V DIMMABLE LED FIXTURE. BOOSTED STANDARD LIGHT OUTPUT. ANGLED LENS. DIFFUSE CENTER. MATTE WHITE. EMERGENCY BATTERY. FINELITE HPR LED -A -2X2 -DCO -B -840 -120V -SC -(NOTE 5) -EM INC LED IL / 4,507 4K 37 1,2,3,4 S 88-1/2" WALL SURFACE CORNER MOUNT LENSED LED FIXTURE. 9.4W/FT. 0- 10V DIMMING TO 1%. SINGLE RUN. SATIN ANODIZE FINISH. •gARTCO BSS755-89-35-DM-9-SM-SN-SA INC LED IL / 7,484 3.5K 70 1,4 T2 2FT VAPOR TIGHT LED STRIP FIXTURE. 3,000 LUMENS, MEDIUM DISTRIBUTION. FROSTED ACRYLIC LENS. 80 CRL LITHONIA DMW2-L24-3000LM-AFL-MD-120-GZ1.40K-80CRI INC LED IL / 3,651 4K 27 1,4 WE WALL PACK LED. WIDE THROW. 3,000 LUMENS. NATURAL ALUMINUM FINISH. WET LISTED. INTEGRAL PHOTOCELL. EMERGENCY BATTERY (20W). LITHONIA WST LED-P2-40K-VW-120-PE-E20WH-DNAXD INC LED IL / 3,000 4K 41 1,2,4 X EXIT SIGN. WHITE HOUSING WITH GREEN LETTERS. BATTERY -BACKED, SELF POWERED. DAMP LISTED. LITHONIA LQM S 11113 G 120/277 EL N INC LED NA NA <1 1,2,4,6 NOTES: * DL = DELIVERED LUMENS, IL = INITIAL LUMENS 1. ALTERNATE MANUFACTURER MUST MEET DESIGN INTENT OF THE PROJECT INCLUDING MINIMUM LIGHT LEVELS. (REFER TO DIVISION 01 FOR SUBSTITUTIONS) 2. COORDINATE FINISH COLORS WITH ARCHITECT. 3. COORDINATE GRID CEILING TYPE WITH ARCHITECT. 4. PROVIDE WITH INTEGRAL BATTERY BACK-UP. PROVIDE UNSWITCHED CIRCUIT TO BATTERY FOR SENSING OF POWER LOSS AND FOR CHARGING OF BATTERY. 5. PENDANT MOUNTED TO SLOPED CEILING. PENDANT FIXTURE SHALL BE MOUNTED 10'-0" AFF AND BE PROVIDED WITH ADJUSTABLE AIRCRAFT CABLES. COORDINATE WITH ARCHITECT FOR MOUNTING AND MOUNTING HEIGHT. ADJUST MOUNTING HEIGHT AS DIRECTED BY ARCHITECT. 6. PROVIDE DOUBLE -FACE OR SINGLE FACE AS REQUIRED. REFER TO ARCHITECTURAL PLANS FOR EGRESS PATHS AND PROVIDE FACES SO EGRESS PATHS HAVE CLEAR VIEWS OF EXIT SIGNS. (A) CUSTODIAN CLST �< c LIGHTING CONTROL ZONE LEGEND: PRIMARY DAYLIGHT ZONE L 1 L J SECONDARY DAYLIGHT. ZONE C GENERAL NOTES 1. LIGHT FIXTURE LOCATIONS ARE SHOWN FOR REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS. 2. PROVIDE UNSWITCHED HOT CONDUCTOR FOR ALL EMERGENCY LIGHTS INCLUDING EXIT SIGNS. FOR SWITCHED EMERGENCY LIGHTS, PROVIDE (2) HOT CONDUCTORS FROM SAME CIRCUIT, (1) SHALL BE THE SWITCHED CONDUCTOR, AND (1) SHALL BE UNSWITCHED FOR CHARGING OF BATTERY AND SENSING OF UTILITY POWER LOSS. 3. LOW—VOLTAGE AND 0-10V CABLING NOT ALWAYS SHOWN TO LIGHT FIXTURES AND LOW—VOLTAGE DEVICES. PROVIDE ALL LOW—VOLTAGE AND 0-10V CABLING AS REQUIRED FOR COMPLETE OPERATION. 4. SENSORS SHALL BE PROGRAMMED AS VACANCY SENSORS (MANUAL ON), UNLESS NOTED OTHERWISE. 5. LIGHTS IN CORRIDOR, LOBBY, AND DRIVER PREP SHALL BE PROGRAMMED AS AUTO ON / AUTO OFF VIA THE ASSOCIATED OCCUPANCY SENSORS. 6. COORDINATE PENDANT FIXTURE MOUNTING HEIGHT WITH ARCHITECT. PLAN NOTES O1 CONTINUES TO SWITCHED RECEPTACLES. REFER TO POWER FLOOR PLAN. 2O REFER TO DETAIL, SHEET TE8.01, FOR CONTROLLED RECEPTACLES SWITCH DETAIL. O 2—BUTTON COMBINE/UNCOMBINE LOW—VOLTAGE SWITCH. O SWITCH SHALL BE PROGRAMMED AS OCCUPANCY SENSING (AUTO ON / AUTO OFF). O LOCATE LIGHTS BETWEEN MECHANICAL DUCTWORK AND EQUIPMENT AND LOCATE BELOW DUCTS. COORDINATE WITH MECHANICAL CONTRACTOR. 06 CONNECT EXHAUST FAN TO LIGHTING CIRCUIT IN ROOM. EXHAUST FAN SHALL BE SWITCHED ON/OFF WITH LIGHTS. MECH ELEC 107 STORAGE 113 LIGHTING FLOOR PLAN SCALE : 1/4" = 1'-0" REVIEWED FOR COMPLIANCE WITH NFPA 70 = NEC MAY 0 5 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 252017 PERMIT CENTER architecture planning inter Or design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 11.114, V� TRES WEST TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com V z E!i U m Cn Z FT - cc) Q D rt J � co J C L oar ui=1. D oq 1— 1— .(c111_ REVISION DATE Design: SKF Drawn: BT Checked: FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/.14/2017 Drawing Title LIGHTING FLOOR PLAN Drawing Number TE7.01eN TE7.01 TB-LIGHTING FLOOR PLAN.DWG 2 o ti CV N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC 120VAC POWER 5 S STRUCTURAL CEILING SUSPENDED CEILING [FININSHED FLOOR TELECOM CONDUIT DETAIL SCALE: NONE O1 WALL TELECOM OUTLET DEVICES AND COVERPLATE. ALL WALL OUTLETS SHALL BE MOUNTED AT SAME HEIGHT AS ADJACENT POWER OUTLETS UNLESS OTHERWISE NOTE. 02 STUB OUT 1" CONDUIT TO ACCESSIBLE CEILING SPACE. PROVIDE PLASTIC BUSHINGS FOR ALL CONDUIT ENDS. NPP2OPLBP CONTROLLED RECEPTACLES SWITCHPACK S 0 (g 0 0 ) CD < SS 0 b 0 Q $, ( TO NEXT SWITCHED b p RECEPTACLE 000 SPLIT CONTROLLED RECEPTACLE DETAIL SCALE: NONE TO NEXT UNSWITCHED RECEPTACLE NOTE: 1. PROVIDE ALL DEVICES, J -BOXES, CONDUIT, WIRING AND CONNECTIONS FOR COMPLETE OPERATION. 2. REFER TO ELECTRICAL POWER & LIGHTING PLAN SHEETS FOR DEVICE QUANTITY. 3. PROVIDE SPLIT CONTROLLED RECEPTACLE WITH CONTROL SYMBOL AND "CONTROLLED" ABOVE OR SIDE OF THE CONTROLLED OUTLET. PART NUMBER LEVITON 5262-S1G OR EQUAL. 4. OCCUPANCY SENSOR WILL CONTROL THE SWITCHED RECEPTACLE. DUAL RJ -45 JACK INSERT FOR UTP UTP CABLE SCHEDULE SPACE FOR OWNER PROVIDED EQUIPMENT DESCRIPTION REMARKS 000000 Waco 000000 000000 1,2 SCHEDULE NOTES: 000000 000000 000000 OOGOOO F I SPACE FOR OWNER PROVIDED EQUIPMENT • /////////////// DUAL RJ -45 JACK INSERT FOR UTP UTP CABLE SCHEDULE TYPE DESCRIPTION REMARKS <>, FOUR PAIR UTP CATEGORY 6 CABLE FOR DATA, DATA, QUANTITY PER DEVICE AS NOTED ON FLOOR PLANS 1,2 SCHEDULE NOTES: AT 1. UTP CABLE ROUTED FROM OUTLETS IN CONDUITS TO ACCESSIBLE CEILING SPACE THEN THROUGH J -HOOKS TO TELECOM RACK. 2. ALL TELECOMMUNICATION CABLES SHALL BE TERMINATED A PATCH PANEL. DETAIL NOTES O SEE FLOOR PLANS FOR LOCATIONS OF TELECOMMUNICATION OUTLETS. PROVIDE QUANTITY OF CAT 6 DROPS PER OUTLET AS INDICATED INSIDE TELECOM SYMBOL ON FLOOR PLANS. ALL CABLING WILL PUNCH DOWN ON PATCH PANELS IN THE MDF AND THEN WILL BE PATCHED FOR VOICE OR DATA WITH PATCH CORDS. SEE THIS SHEET AND SPECIFICATION 271000 FOR ADDITIONAL OUTLET REQUIREMENTS. O2 PROVIDE FREE STANDING UPRIGHT FLOOR MOUNTED RACK PER SPECIFICATION SECTION 271000. PROVIDE VERTICAL MANAGEMENT AT BOTH ENDS OF EACH RACK PER SPECIFICATION SECTION 271000. O PROVIDE UTP WIRE MANAGEMENT PANELS AS SHOWN PER SPECIFICATION SECTION 271000. O PROVIDE RACK MOUNTED CAT. 6 HIGH DENSITY PATCH PANEL PER SPECIFICATION SECTION 271000 AND TERMINATE ALL UTP CABLES. 0 PROVIDE GROUND BUS BAR KIT CPI #10622-010 ON WALL AS INDICATED ON FLOOR PLAN. GROUND BUS BAR ON WALL TO CLOSEST NEC CODE RECOGNIZED GROUND. GROUND ALL RACKS FROM GROUND LUG AT EACH RACK TO BUS BAR ON WALL. ALL GROUND WIRE SHALL BE #6 AWG INSULATED Cu. GROUND LUG ON RACK TO BE ORTRONICS PART #OR -60400010. O PROVIDE VERTICAL CABLE MANAGEMENT AT BOTH ENDS OR RACK PER SPECIFICATIONS 271000. TELECOM MDF RACK STORAGE RM 106 SCALE: NONE JACK IDENTIFICATION MDF -1-1 MDF -1-2 BLANK FILLERPLATE J JACK IDENTIFICATION LABEL 16 POINT TYPE LETTERING BLACK ON WHITE DUAL RJ -45 JACK INSERT FOR UTP DUAL RJ -45 JACK INSERT FOR UTP SINGLE GANG FACEPLATE NOTES: 1. PROVIDE DOUBLE GANG COVERPLATES IN AREAS REQUIRING MORE DROPS THEN WILL FIT INTO A SINGLE GANG PLATE. 2. PROVIDE 5 SQUARE BACK BOXES AT ALL TELECOM OUTLET LOCATIONS. 3. DETAILS ARE SHOWN AS A GUIDELINE AND ARE NOT A REPRESENTATION OF EVERY SITUATION. 4. SEE SPECIFICATION SECTION 271000 FOR MORE REQUIREMENTS. 5. SEE FLOOR PLANS WHERE SUB -NUMBER IN SYMBOL INDICATES QUANTITIES OF DROPS PER OUTLET. TYPICAL TELECOM WALL OUTLET DETAILS SCALE: NONE LOCATE IN STORAGE ROOM 106. SEE FLOOR PLANS FOR LOCATION. 1 /4"x4"x10" COPPER GROUND BAR WITH WALL MOUNTING BRACKETS AND INSULATORS CPI#10622-010 an GROUND BUS BAR ASSEMBLY SCALE: NONE REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAY 0 5 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 252017 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com V J z 0 � 0—J 0 La Z U0 _I I— o co < OJ L]- -0) ii::: C'4. ui REVISION DATE Design: Drawn: Checked: SKF BT FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/14/2017 Drawing Title ELECTRICAL DIAGRAMS AND DETAILS Drawing Number TE8.01 TB -ELECTRICAL DIAGRAMS AND DETAILS.DWG COPYRIGHT 0 2015 ROLLUDA ARCHITECTS INC co ti N N PROVIDE CONNECTION TO LOCAL AREA NETWORK 120VAC, 20A 120V, 20A CIRCUIT NOTES: SAP ACCESS CONTROL 4 -READER PANEL DOOR LOCK POWER SUPPLY BATTERY CABINET FAP SECURITY ALARM CONNECTION FOR DISARMING. FIRE ALARM CONNECTION FOR UNLOCK. J -BOX ABOVE ACCESS CONTROL DOORS O J REMOTE RELAY ADA DOOR OPENER 120V, 20A O REMOTE RELAY ELECTRIC DOOR LOCK REQUEST TO EXIT MOTION 1�1 DETECTOR ( REX ) © CARD READER TYPICAL DOOR COMPONENTS ALL WIRING TO BE HOMERUN TO THE SECURITY CONTROL PANEL 1. PROVIDE ALL J -BOXES, CONDUIT, WIRING AND CONNECTIONS TO ALL DEVICES FOR COMPLETE OPERATIONAL SYSTEM. 2. PROVIDE COMPLETE ACCESS CONTROL SYSTEMS PER ELECTRICAL PLANS, MECHANICAL PLANS, ARCHITECTURAL PLANS, SPECIFICATIONS AND CODE REQUIREMENTS. 3. PROVIDE REQUIRED 4 -READER CONTROL UNITS AND RELAYS TO OPERATE ALL AUXILIARY DEVICES. 4. DOOR CONTRACTOR TO PROVIDE, INSTALL, AND POWER ELECTRIC DOOR LOCKS. 5. PROVIDE J -BOX ABOVE THE DOOR TO CONNECT DOOR POSITION SWITCH WIRING. 6. PROVIDE J -BOX ABOVE THE DOOR TO CONNECT ELECTRIC DOOR LOCK WIRING. 7. CARD READER ZONE WILL INTERFACE ACCESS CONTROL SYSTEM WITH SECURITY PANEL TO DISARMING SECURITY ZONE. 8. PROVIDE CARD READER PEDESTAL(S) AS REQUIRED. 9. PROVIDE INTERFACES WITH SECURITY SYSTEM PER SECURITY PARTITION SCHEDULE. 10. PROVIDE INTERFACES WITH SECURITY SYSTEM FOR LOCK -DOWN OF THE SCHOOL. THIS WILL BE MONITORED BY CENTRAL STATION. 11. PROVIDE INTERFACE WITH MASTER DOOR INTERCOM STATION TO UNLOCK MAIN ENTRY GATE. 3/4"C.O. ACCESS CONTROL SINGLE -LINE DIAGRAM SCALE: NONE 3/4"C.O. 3/4"C.O. DOOR OPENER INTERIOR DOOR DOOR STRIKE WIRING DIAGRAM REQUIREMENTS 1. PROVIDE COMPLETE RACEWAY FOR ACCESS CONTROLS. COORDINATE INSTALLATIONS WITH OWNER'S SECURITY DEPARTMENT PRIOR TO ROUGH -IN. 2. CARD READERS AT ENTRY DOORS 130-A AND 130-B TO UNLATCH BOTH ENTRY DOORS 130-A AND 130-B. HANDICAP DOOR OPERATORS TO OPERATE ONLY ASSOCIATED ENTRY DOOR AS SHOWN ON PLANS. DETAIL NOTES OPROVIDE 1"C AND POWER TO CONTROLLER. COORDINATE LOCATION IN FIELD WITH DOOR CONTRACTOR. O 0 DOOR OPENER POWER SUPPLY CONTROL PANEL BY DOOR CONTRACTOR. COORDINATE AS REQUIRED. 3/4"C.O. FOR DOOR CONTACT CONNECT THRU DOOR HINGE. COORDINATE INSTALLATION WITH DOOR CONTRACTOR. DOOR OPENER INTERIOR PUSH PLATE. DOOR OPENER EXTERIOR PUSH PLATE. PROVIDE WEATHERPROOF PUSH PLATE, BOX AND COVER. WIRING DIAGRAM FOR ADA DOOR CONTROLS SCALE: NONE ADMIN AREA 3/4"C TO DDC 3/4"C TO LCP ADMIN AREA KEYPAD CONFERENCE/TRAINING/BREAK AREA PROVIDE CONNECTION TO LOCAL AREA NETWORK NOTES: NEW SECURITY ALARM CONTROL PANEL FULL INTELLIGENT ADDRESSABLE SYSTEM CONFERENCE/TRAINING/BREAK AREA 1 KEYPAD INTERFACE WITH ACCESS CONTROL 120VAC, 20A 1. PROVIDE ALL J -BOXES, CONDUIT, WIRING AND ALL CONNECTIONS TO DEVICES FOR COMPLETE OPERATIONAL SYSTEM. 2. PROVIDE FLUSH MOUNT BACK BOXES FOR ALL DEVICES IN ALL FINISHED SPACES. 3. PROVIDE REQUIRED CONTROL RELAYS TO OPERATE ALL AUXILIARY DEVICES. 4. PROVIDE COMPLETE GROUNDING TO EQUIPMENT. 5. PROVIDE COMPLETE INSTALLATIONS PER SYSTEM SHOP DRAWINGS. 6. PROVIDE COMPLETE EQUIPMENT, DEVICES AND CONNECTIONS TO UL LISTED MONITORING STATION PER OWNER'S DIRECTION. 7. REFER TO SECURITY ALARM SPECIFICATIONS FOR COMPLETE DETAILS. 8. PROVIDE COMPLETE PROGRAMMING OF SYSTEM TO UPDATE ALL ZONES, ADDRESSES, AND DIALER. PROVIDE NEW DIALER IF REQUIRED. 9. PROVIDE J -BOX ABOVE DOOR TO CONNECTION SECURITY DOOR CONTACT SWITCH WIRING. 10. CARD READER ZONE WILL INTERFACE ACCESS CONTROL SYSTEM WITH SECURITY PANEL TO DISARMING SECURITY ZONE. 11. PROVIDE AND PROGRAM TWO CONTACTS THAT WILL ACTIVE ON ALARM OR TROUBLE OF THE SECURITY SYSTEM. THESE CONTRACTS WILL INTERFACE WITH THE BUILDING DDC CONTROL PANEL AND THE LIGHTING CONTROL PANEL (LCP) TO TURN INTERIOR AND EXTERIOR LIGHTING TO FULL ON. 12. PROVIDE POINT MODULES OR SOFTWARE PROGRAMMING TO INTERFACE ACCESS CONTROL SYSTEM TO MONITOR LOCKDOWN OF THE SCHOOL TO CENTRAL STATION. SECURITY ALARM SYSTEM ONE -LINE DIAGRAM SCALE: NONE Inc. DCD 1/2"C SECURITY CABLING FIELD VERIFY AND COORDINATE WITH SUPPLIER FOR LOCATION. CONNECT TO SECURITY SYSTEM 1/2"C 0 0 SINGLE DOOR DETAIL NOTES FINISHED FLOOR OPROVIDE COMPLETE ROUGH -IN FOR DOOR CONTROL DEVICES AND NEW STRIKE HARDWARE. CONCEAL ALL INSTALLATIONS. SEE FLOOR PLANS. OPROVIDE ROUGH -IN FOR DOOR CONTROL DEVICES, PASS-THROUGH HINGE, AND NEW STRIKE HARDWARE. CONCEAL ALL INSTALLATIONS. SEE FLOOR PLANS. OPROVIDE CONDUIT TO ELECTRIC LOCK AND STRIKE PLATE. COORDINATE WITH DOOR HARDWARE SUPPLIER FOR PROPER ROUGH -IN. NOTES 1. PROVIDE DOOR CONTACTS ARE SHOWN ON FLOOR PLANS FOR MULTIPLE AND SINGLE DOORS. DOOR ACCESS CONTROL AND SECURITY DETAIL SCALE: NONE GENERATOR GENERAL TROUBLE CONTACTS GENERATOR RUNNING SUPERVISORY CONTACT POST INDICATOR VALVE & VAULT TAMPER SWITCHES BACKFLOW TAMPER SWITCHES WET FIRE SPRINKLER RISER TAMPER SWITCHES WET FIRE SPRINKLER RISER FLOW SWITCHES EMCS CONTROL ACCESS CONTROL PANEL DEDICATED 120V CIRCUITS, SEPARATE HOME RUN AND INSULATED GROUND. CONTROL RELAY QD ED DOOR HOLDER CIRCUIT CONTROL RELAY R RETURN i PROVIDE AND CONNECT ' TO 120VAC POWER J J c .\ FIRE/SMOKE DAMPER CIRCUIT FIRE ALARM AUDIO/VISUAL ALARM CIRCUIT TYPICAL F FIRE ALARM SLC LOOP DEVICES AND DETECTORS 0 PROVIDE REMOTE INDICATING LIGHT TO SIGNAL SMOKE DUCT Ile7 DETECTOR ACTIVATION. MOUNT IN CEILING BELOW UNIT. PROVIDE DUCT SMOKE DETECTORS FOR ALL MECHANICAL UNITS OF 2000 CFM AND OVER SEE MECH DRAWING EQUIP. SCHEDULES. HVAC DDC CONTROL PANEL HVAC FOR HVAC SHUT DOWN PROVIDE RADIO REMOTE ANTENNA IN CATWALK OR ON ROOF ABOVE FIRE ALARM. PROVIDE RADIO ANTENNA o� CABLE AS REQUIRED. RADIO DIALER 11 120V DEDICATED CIRCUIT GROUNDING H__4 A F.A. PANEL FA -NAC BOOSTER PANEL MAP FAA 4 -GROUNDING AUDIO/VISUAL ALARM CIRCUIT TYPICAL 120V DEDICATED CIRCUIT FIRE ALARM REMOTE GRAPHIC LED ANNUNCIATOR MAP FIRE ALARM REMOTE LCD ANNUNCIATOR WITH MICROPHONE BATTERY CABINET GROUNDING NEW F.A. PANEL LOCATED IN NEW MECH/ELEC ROOM 107 SEE SHEET E3.01 FOR LOCATION PROVIDE ETHERNET CAT -6 CABLE WITH RJ45 FOR EMAIL MONITORING OF THE LOCAL FIRE ALARM PANEL REFER TO ELECTRICAL PLANS. TYPICAL FIRE ALARM SYSTEM ONE -LINE DIAGRAM SCALE: NONE NOTES: 1. ALL FIRE ALARM PANELS AND DEVICES ARE FOR BASES OF DESIGN. FIRE ALARM CONTRACTOR SHALL PROVIDE A FULL COVERAGE BIDDER DESIGN FIRE ALARM SYSTEM TO BE APPROVED BY AHJ. 2. ALL FIRE ALARM WIRING SHALL BE INSTALLED IN CONDUIT. 3. PROVIDE ALL J -BOXES, CONDUIT, WIRING & CONNECTIONS TO ALL DEVICES FOR COMPLETE FIRE ALARM SYSTEM. 4. ALL DEVICES WILL BE MOUNTED IN AN ACCESSIBLE SPACE AND AT THE ELEVATION PER NFPA 72, ADA, AND AHJ CODES. 5. PROVIDE FLUSH MOUNT BACK BOXES FOR ALL DEVICES IN ALL FINISHED SPACE. 6. PROVIDE COMPLETE GROUNDING TO EQUIPMENT PER MANUFACTURERS RECOMMENDATION. 7. SEE FIRE ALARM SPECIFICATION FOR COMPLETE DETAILS. 8. PROVIDE NEW FIRE ALARM PANEL ADDRESSABLE. 9. PROVIDE SHUT DOWN CONNECTIONS FOR ALL 2000CFM HVAC UNITS WITH DUCT DETECTORS AS SHOWN. 10. SET ALL VISUAL DEVICES TO PROVIDE THE RIGHT COVERAGE OF CANDELA FOR THE SPACE PER NFPA 72 AND AHJ CODES. 11. SET ALL AUDIO DEVICES TO TEMPORAL AND TO BE 15dB ABOVE AMBIENT SOUND LEVEL OF THE ROOM PER NFPA 72 CODES TABLE. 12. ALL AUDIO AND VISUAL DEVICE WILL BE SYNC PER NFPA 72 CODES. 13. PROVIDE COMPLETE REPROGRAMMING OF FIRE ALARM SYSTEM TO ALL ZONES, ADDRESSES, AND MONITORING BY POINTS AND ALL EVENTS TO CENTRAL STATION MONITORING. 14. PROVIDE COMPLETE SHOP PLANS FOR INSTALLATION AND AS -BUILT SET OF THESE PLANS NEXT TO FIRE ALARM PANEL ON COMPLETION. 15. PROVIDE CD-ROM, DVD, OR FINGER DRIVE OF PROGRAM DATA IN FIRE ALARM PANEL AS REQUIRED BY NFPA-72 CODES. 16. PROVIDE PLENUM RATED FIRE CABLE FOR ALL NAC HORN/STROBE CIRCUITS. MINIMUM CABLING REQUIREMENT SIZE 2#14 CABLE FOR HORN, 2#14 CABLE FOR NAC STROBE LIGHT FIRE, AND 2#14 CABLE FOR COMBINATION HORN/STROBE LIGHT FIRE . EL REVIEWED FOR COMPLIANCE WITH NEPA 70 NEC MAY 05 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 252017 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com V Z 0 OJ Z D 0 m Cn Z 0 0 J F- CO Q F- aC 0 J o§ 2 - 2 0 Q _1co Z c) Q'S wg O CoCNI REVISION DATE Design: SKF Drawn: BT Checked: FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/14/2017 Drawing Title ELECTRICAL. DIAGRAMS AND DETAILS Drawing Number TE8.02 TE8.02 TB -ELECTRICAL DIAGRAMS AND DETAILS.DWG 2 co ti N N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC DOOR OPENER EXTERIOR DOOR r fi DOOR` STRIKE WIRING DIAGRAM REQUIREMENTS 1. PROVIDE COMPLETE RACEWAY FOR ACCESS CONTROLS. COORDINATE INSTALLATIONS WITH OWNER'S SECURITY DEPARTMENT PRIOR TO ROUGH -IN. 2. CARD READERS AT ENTRY DOORS 130-A AND 130-B TO UNLATCH BOTH ENTRY DOORS 130-A AND 130-B. HANDICAP DOOR OPERATORS TO OPERATE ONLY ASSOCIATED ENTRY DOOR AS SHOWN ON PLANS. DETAIL NOTES OPROVIDE 1"C AND POWER TO CONTROLLER. COORDINATE LOCATION IN FIELD WITH DOOR CONTRACTOR. O 0 DOOR OPENER POWER SUPPLY CONTROL PANEL BY DOOR CONTRACTOR. COORDINATE AS REQUIRED. 3/4"C.O. FOR DOOR CONTACT CONNECT THRU DOOR HINGE. COORDINATE INSTALLATION WITH DOOR CONTRACTOR. DOOR OPENER INTERIOR PUSH PLATE. DOOR OPENER EXTERIOR PUSH PLATE. PROVIDE WEATHERPROOF PUSH PLATE, BOX AND COVER. WIRING DIAGRAM FOR ADA DOOR CONTROLS SCALE: NONE ADMIN AREA 3/4"C TO DDC 3/4"C TO LCP ADMIN AREA KEYPAD CONFERENCE/TRAINING/BREAK AREA PROVIDE CONNECTION TO LOCAL AREA NETWORK NOTES: NEW SECURITY ALARM CONTROL PANEL FULL INTELLIGENT ADDRESSABLE SYSTEM CONFERENCE/TRAINING/BREAK AREA 1 KEYPAD INTERFACE WITH ACCESS CONTROL 120VAC, 20A 1. PROVIDE ALL J -BOXES, CONDUIT, WIRING AND ALL CONNECTIONS TO DEVICES FOR COMPLETE OPERATIONAL SYSTEM. 2. PROVIDE FLUSH MOUNT BACK BOXES FOR ALL DEVICES IN ALL FINISHED SPACES. 3. PROVIDE REQUIRED CONTROL RELAYS TO OPERATE ALL AUXILIARY DEVICES. 4. PROVIDE COMPLETE GROUNDING TO EQUIPMENT. 5. PROVIDE COMPLETE INSTALLATIONS PER SYSTEM SHOP DRAWINGS. 6. PROVIDE COMPLETE EQUIPMENT, DEVICES AND CONNECTIONS TO UL LISTED MONITORING STATION PER OWNER'S DIRECTION. 7. REFER TO SECURITY ALARM SPECIFICATIONS FOR COMPLETE DETAILS. 8. PROVIDE COMPLETE PROGRAMMING OF SYSTEM TO UPDATE ALL ZONES, ADDRESSES, AND DIALER. PROVIDE NEW DIALER IF REQUIRED. 9. PROVIDE J -BOX ABOVE DOOR TO CONNECTION SECURITY DOOR CONTACT SWITCH WIRING. 10. CARD READER ZONE WILL INTERFACE ACCESS CONTROL SYSTEM WITH SECURITY PANEL TO DISARMING SECURITY ZONE. 11. PROVIDE AND PROGRAM TWO CONTACTS THAT WILL ACTIVE ON ALARM OR TROUBLE OF THE SECURITY SYSTEM. THESE CONTRACTS WILL INTERFACE WITH THE BUILDING DDC CONTROL PANEL AND THE LIGHTING CONTROL PANEL (LCP) TO TURN INTERIOR AND EXTERIOR LIGHTING TO FULL ON. 12. PROVIDE POINT MODULES OR SOFTWARE PROGRAMMING TO INTERFACE ACCESS CONTROL SYSTEM TO MONITOR LOCKDOWN OF THE SCHOOL TO CENTRAL STATION. SECURITY ALARM SYSTEM ONE -LINE DIAGRAM SCALE: NONE Inc. DCD 1/2"C SECURITY CABLING FIELD VERIFY AND COORDINATE WITH SUPPLIER FOR LOCATION. CONNECT TO SECURITY SYSTEM 1/2"C 0 0 SINGLE DOOR DETAIL NOTES FINISHED FLOOR OPROVIDE COMPLETE ROUGH -IN FOR DOOR CONTROL DEVICES AND NEW STRIKE HARDWARE. CONCEAL ALL INSTALLATIONS. SEE FLOOR PLANS. OPROVIDE ROUGH -IN FOR DOOR CONTROL DEVICES, PASS-THROUGH HINGE, AND NEW STRIKE HARDWARE. CONCEAL ALL INSTALLATIONS. SEE FLOOR PLANS. OPROVIDE CONDUIT TO ELECTRIC LOCK AND STRIKE PLATE. COORDINATE WITH DOOR HARDWARE SUPPLIER FOR PROPER ROUGH -IN. NOTES 1. PROVIDE DOOR CONTACTS ARE SHOWN ON FLOOR PLANS FOR MULTIPLE AND SINGLE DOORS. DOOR ACCESS CONTROL AND SECURITY DETAIL SCALE: NONE GENERATOR GENERAL TROUBLE CONTACTS GENERATOR RUNNING SUPERVISORY CONTACT POST INDICATOR VALVE & VAULT TAMPER SWITCHES BACKFLOW TAMPER SWITCHES WET FIRE SPRINKLER RISER TAMPER SWITCHES WET FIRE SPRINKLER RISER FLOW SWITCHES EMCS CONTROL ACCESS CONTROL PANEL DEDICATED 120V CIRCUITS, SEPARATE HOME RUN AND INSULATED GROUND. CONTROL RELAY QD ED DOOR HOLDER CIRCUIT CONTROL RELAY R RETURN i PROVIDE AND CONNECT ' TO 120VAC POWER J J c .\ FIRE/SMOKE DAMPER CIRCUIT FIRE ALARM AUDIO/VISUAL ALARM CIRCUIT TYPICAL F FIRE ALARM SLC LOOP DEVICES AND DETECTORS 0 PROVIDE REMOTE INDICATING LIGHT TO SIGNAL SMOKE DUCT Ile7 DETECTOR ACTIVATION. MOUNT IN CEILING BELOW UNIT. PROVIDE DUCT SMOKE DETECTORS FOR ALL MECHANICAL UNITS OF 2000 CFM AND OVER SEE MECH DRAWING EQUIP. SCHEDULES. HVAC DDC CONTROL PANEL HVAC FOR HVAC SHUT DOWN PROVIDE RADIO REMOTE ANTENNA IN CATWALK OR ON ROOF ABOVE FIRE ALARM. PROVIDE RADIO ANTENNA o� CABLE AS REQUIRED. RADIO DIALER 11 120V DEDICATED CIRCUIT GROUNDING H__4 A F.A. PANEL FA -NAC BOOSTER PANEL MAP FAA 4 -GROUNDING AUDIO/VISUAL ALARM CIRCUIT TYPICAL 120V DEDICATED CIRCUIT FIRE ALARM REMOTE GRAPHIC LED ANNUNCIATOR MAP FIRE ALARM REMOTE LCD ANNUNCIATOR WITH MICROPHONE BATTERY CABINET GROUNDING NEW F.A. PANEL LOCATED IN NEW MECH/ELEC ROOM 107 SEE SHEET E3.01 FOR LOCATION PROVIDE ETHERNET CAT -6 CABLE WITH RJ45 FOR EMAIL MONITORING OF THE LOCAL FIRE ALARM PANEL REFER TO ELECTRICAL PLANS. TYPICAL FIRE ALARM SYSTEM ONE -LINE DIAGRAM SCALE: NONE NOTES: 1. ALL FIRE ALARM PANELS AND DEVICES ARE FOR BASES OF DESIGN. FIRE ALARM CONTRACTOR SHALL PROVIDE A FULL COVERAGE BIDDER DESIGN FIRE ALARM SYSTEM TO BE APPROVED BY AHJ. 2. ALL FIRE ALARM WIRING SHALL BE INSTALLED IN CONDUIT. 3. PROVIDE ALL J -BOXES, CONDUIT, WIRING & CONNECTIONS TO ALL DEVICES FOR COMPLETE FIRE ALARM SYSTEM. 4. ALL DEVICES WILL BE MOUNTED IN AN ACCESSIBLE SPACE AND AT THE ELEVATION PER NFPA 72, ADA, AND AHJ CODES. 5. PROVIDE FLUSH MOUNT BACK BOXES FOR ALL DEVICES IN ALL FINISHED SPACE. 6. PROVIDE COMPLETE GROUNDING TO EQUIPMENT PER MANUFACTURERS RECOMMENDATION. 7. SEE FIRE ALARM SPECIFICATION FOR COMPLETE DETAILS. 8. PROVIDE NEW FIRE ALARM PANEL ADDRESSABLE. 9. PROVIDE SHUT DOWN CONNECTIONS FOR ALL 2000CFM HVAC UNITS WITH DUCT DETECTORS AS SHOWN. 10. SET ALL VISUAL DEVICES TO PROVIDE THE RIGHT COVERAGE OF CANDELA FOR THE SPACE PER NFPA 72 AND AHJ CODES. 11. SET ALL AUDIO DEVICES TO TEMPORAL AND TO BE 15dB ABOVE AMBIENT SOUND LEVEL OF THE ROOM PER NFPA 72 CODES TABLE. 12. ALL AUDIO AND VISUAL DEVICE WILL BE SYNC PER NFPA 72 CODES. 13. PROVIDE COMPLETE REPROGRAMMING OF FIRE ALARM SYSTEM TO ALL ZONES, ADDRESSES, AND MONITORING BY POINTS AND ALL EVENTS TO CENTRAL STATION MONITORING. 14. PROVIDE COMPLETE SHOP PLANS FOR INSTALLATION AND AS -BUILT SET OF THESE PLANS NEXT TO FIRE ALARM PANEL ON COMPLETION. 15. PROVIDE CD-ROM, DVD, OR FINGER DRIVE OF PROGRAM DATA IN FIRE ALARM PANEL AS REQUIRED BY NFPA-72 CODES. 16. PROVIDE PLENUM RATED FIRE CABLE FOR ALL NAC HORN/STROBE CIRCUITS. MINIMUM CABLING REQUIREMENT SIZE 2#14 CABLE FOR HORN, 2#14 CABLE FOR NAC STROBE LIGHT FIRE, AND 2#14 CABLE FOR COMBINATION HORN/STROBE LIGHT FIRE . EL REVIEWED FOR COMPLIANCE WITH NEPA 70 NEC MAY 05 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 252017 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com V Z 0 OJ Z D 0 m Cn Z 0 0 J F- CO Q F- aC 0 J o§ 2 - 2 0 Q _1co Z c) Q'S wg O CoCNI REVISION DATE Design: SKF Drawn: BT Checked: FLR Project No. 331-16-01 Issuance PERMIT SET Date: 4/14/2017 Drawing Title ELECTRICAL. DIAGRAMS AND DETAILS Drawing Number TE8.02 TE8.02 TB -ELECTRICAL DIAGRAMS AND DETAILS.DWG 2 co ti N N COPYRIGHT © 2015 ROLLUDA ARCHITECTS INC