Loading...
HomeMy WebLinkAboutPermit PL14-0010 - RONALD MECKLER / CROWN CASTLE - SPRINT TYPE I WIRELESS TELECOMMUNICATIONS FACILITIES PERMITSPRINT 2.5 TUKWILA SE03XC408 12200 51ST PL S P L 14-0010 L14-0018 TYPE 1 WIRELESS City of Tukwila Department of Community Development April 15, 2014 NOTICE OF DECISION TO: Ronald Meckler Crown Castle 8432 154th Ave NE Redmond, WA 98052 Jim Haggerton, Mayor Jack Pace, Director This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit approval. Project File Number: Applicant: Type of Permit Applied for: Project Description: Location: Associated Files: Comprehensive Plan Designation/Zoning District: I. PROJECT INFORMATION L14-0018, PL 14-0010 Ron Meckler, Crown Castle (obo Sprint PCS) Type 1 Wireless Telecommunications Facilities Permit Approval of a Type I Wireless Telecommunication Facilities Permit to upgrade existing antennas, cabinets and associated cabling on an existing wireless facilities tower. No ground disturbance or expansion of the existing compound is proposed. Tax Lot NO: 0003800003. This tower is located at 12200 51st Pl. S., Tukwila, WA 98178. N/A Manufacturing Industrial Center/Heavy Industrial (MIC/H) II. DECISION SEPA Determination: The City SEPA Responsible Official has previously determined that this application does not require a SEPA threshold determination because it is categorically exempt. Decision on Substantive Permit: The City Community Development Department has determined that the application for a Type 1 Wireless Communications Facility does comply with applicable City and state code requirements and has approved that application without conditions. MB Page 1 of 3 04/15/2014 W:\Users\Max\L14-0017\L14-0018 NOD.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code § 18.104.010. Other land use applications related to this project may still be pending. No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to challenge either the conditions which were imposed by the MDNS decision or the failure of the Department to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing Examiner. A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in King County Superior Court from the Hearing Examiner's decision. IV. PROCEDURES AND TIME FOR APPEALING In order to appeal the Community Development Director decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14 days of the issuance of this decision, that is by April 29, 2014. The requirements for such appeals are set forth in Tukwila Municipal Code ch. 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing party's behalf. 3. A statement identifying the decision being appealed and the alleged errors in the decision, including any specific challenge to an MDNS. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. 5. Appeal fee of $541 plus retainer. V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the Hearing Examiner based on the information presented to the Community Development Director, who made the original decision. No new evidence or testimony will be permitted during the appeal hearing. Parties will be allowed to present oral argument based on the information presented to the Community Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is the City's final decision. MB Page 2 of 3 04/15/2014 Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW ch. 36.70C. An appeal challenging a DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the subject property. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Max Baker, who may be contacted at 206-431-3662 or via email at max.baker@tukwilawa.gov for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. Department of Community Development City of Tukwila MB Page 3 of 3 04/15/2014 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director STAFF REPORT TO THE DIRECTOR PREPARED April 15, 2014 NOTIFICATION: Notification is not required for a Type I land use application. FILE NUMBER: L14-0018, PL14-0010 APPLICANT: Ron Meckler, Crown Castle (obo Sprint PCS) PROPERTY OWNER: Burlington Northern Railway Company REQUEST: Approval of a Type I Wireless Telecommunication Facilities Permit to upgrade existing antennas, cabinets and associated cabling on an existing wireless facilities tower. LOCATION: Tax Lot NO: 0003800003. This tower is located at 12200 51st Pl. S., Tukwila, WA 98178. ASSOCIATED PERMITS: Electrical permits issued through the City of Tukwila will be required for service alteration for any other electrical service work this is anticipated but not noted on the plans, per article 85.13 (B), Washington electrical code. Building permit is not required for scope of work stated on the submitted plans. SEPA DETERMINATION: Exempt COMPREHENSIVE PLAN DESIGNATION: Manufacturing Industrial Center/Heavy Industrial (MIC/H) ZONE DESIGNATION: Manufacturing Industrial Center/Heavy Industrial (MIC/H) STAFF: Max Baker, Planning Intern ATTACHMENTS: Project Plans for Permit L14-0018 FINDINGS Vicinity/Site Information 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 Project Description The applicant is requesting approval of a Type I Wireless Telecommunication Facilities [WCF] Permit to add equipment on an existing tower at 12200 51st Ave Pl. S. The project includes: • Install 2.5 equipment in existing cabinet • Add (3) antenna (1 per sector) • Install (3) RRH units (1 per sector) • Install (6) Junction Cylinders • Install (3) Filters The existing cellular tower is 80 feet high with the proposed Sprint antennas to be mounted at 77 feet adjacent to existing Sprint antennas. Existing Development This site is adjacent to Burlington Northern Santa Fe rail yard. In addition to the tower, the site functions as a storage and staging area for rail containers and includes at least two buildings. Surrounding Land Uses The property and the surrounding parcels to the north are zoned MIC/H. To the immediate east are rail lines and freeway. To the south and west, the adjacent properties are zoned LDR. BACKGROUND In 2006, the City adopted a Wireless Facilities Chapter (TMC 18.71) to the Zoning Code. The chapter provides specific location and design requirements for the placement of WCF within the City of Tukwila. The WCF being modified was originally approved by the City in 1997 (L97-0030) through a conditional use permit. In 2012 the WCF was approved for modifications (L12-032) through a Type 1 Wireless facilities permit. Location Selection Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co -locations and utilizing existing structures are favored over the development of new standalone WCF within the City. TABLE A Type of Permit Required, Based on Type of Wireless Communication Facility ZONING (1) TYPE OF FACILITY RESIDENTIAL COMMERCIAL INDUSTRIAL Transmission Tower co -location Type 1 Type 1 Type 1 Adding antennas to an existing tower Type 1(2) Type 1(2) Type 1(2) Utility pole co -location Type 2 Type 2 Type 2 Concealed building attached Type 2(3) Type 2(3) Type 2(3) Non -concealed building attached Type 2 Type 2 Type 1 New tower or waiver request Type 4 Type 4 Type 4 SM (1) Zoning for any private/public property or right-of-way Residential — LDR, MDR, or HDR Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS Industrial - LI, HI, MIC/L, or MIC/H (2) Provided the height of the tower does not increase and the square footage of the enclosure area does not increase. Page 2 of 5 04/15/2014 (3) An applicant may request to install a non -concealed building attached facility, under TMC Section 18.58.150. The applicant is adding additional antennas to an existing tower. This decision does not require the use of any new facilities for placement of the new antennas. Design Standards The City provides specific design standards for the placement of WCF within the City of Tukwila. The table below indicates if the applicant's proposal complies with required standards. Table 1(See TMC 18.58.070 for further details General Requirements Project does comply Project does not comply Not Applicab le Notes 1. Generators or other devices which will create noise must comply with TMC 8.22 regarding noise. X The applicant has not proposed a new generator. 2.Business License Requirement X Sprint has applied for a business license (00008547) 3. Only safety signage must be placed on the WCF. X The applicant does not propose any signage. 4. Accommodations for parking for maintenance personal must be provided. X Parking is not affected by this modification. 5. Towers shall either maintain a galvanized steel finish or be painted a neutral color so as to reduce its visual obtrusiveness. X No change to the existing tower is proposed. 6. The design of all buildings and ancillary structures shall use materials, colors, textures, screening, and landscaping that will blend the tower facilities to the natural setting and built environment. X No new buildings or structures are proposed. 7. Antennas shall have the same color scheme as the structure they are located on. X The existing pole is galvanized steel. No change to the color of the existing antennas and equipment is proposed. The current equipment color blends with the pole color. 8. WCF poles and towers shall only have safety lights if required by a government agency. X No lighting is proposed. 9. No advertising is permitted on WCF X No advertising is proposed. 10. Each service provider shall be limited to an equipment enclosure of 360 square feet. X No change to the existing equipment enclosure is proposed. SM Page 3 of 5 04/15/2014 Table 2 (See TMC 18.58.090 for additional information) Adding Antennas to Existing WCF Tower- Specific Development Standards Project does comply Project does not comply Not Applicab le Notes 1. When adding antennas to existing WCF towers, height must not exceed what was approved under the original application to construct the tower. X No change to the previously approved tower height of 80' is proposed. 2. Antennas shall be painted to match the color scheme of tower. X Antennas and ancillary equipment will be painted to match the existing tower color. 3. There is no limit on the number of antennas that may be located on an existing tower. X 4. Feed lines and coaxial cables shall be located within the tower. Those exposed shall be painted to match tower. X Cables shall be routed within the tower. The jumper cables will be painted to match the antennas. 5. A new cabinet shall be located within the equipment enclosure that was approved as part of the original application, or it will require a Type 2 decision. X No new cabinets are to be installed. 6. Setbacks shall not apply when an applicant installs new antennas on an existing tower and uses an existing equipment enclosure. If the equipment enclosure is increased, it must meet setbacks. X There is no change to the existing equipment enclosure. SM CONCLUSIONS 1. The proposed modifications to the existing antenna will not significantly alter the conditions that currently exist and will not be materially detrimental to the public welfare or injurious to property or improvements in the vicinity. 2. As demonstrated in Tables 1 and 2, the project meets all applicable development standards for a Type 1 WCF. 3. The proposed modifications will not alter the surrounding land uses in terms of traffic and pedestrian circulation, building or site design. Page 4 of 5 04/15/2014 4. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy Plan. RECOMMENDATIONS The recommendation to the Director of Community Development is to approve this application for a Type I Wireless Telecommunication Facility permit as applied for by Crown Castle for Sprint without conditions. INFORMATIONAL ITEMS A City of Tukwila electrical permit is required for service alteration. Please note that the installation of an emergency power disconnect switch is required for fire department use. Contact Don Tomaso at 206-971-8723 to get more information about permit requirements for the power disconnect switch. SM Page 5 of 5 04/15/2014 fi\) CcYE 3/6/2014 MAR 10 2014 City of Tukwila Department of Community Deivelopxmermtwr 6300 Southcenter Blvd. Tukwila, WA 98188 Re: Project Description Sprint 2.5 Site SE03XC408 TUKWILA 12200 51ST Place S Crown Castle Ron Meckler 8547 154th Avenue NE Redmond, WA 98052 Tel: 425-202-2763 Mobile: 206-384-2454 Fax: 724-416-6261 Ronald.Meckler@crowncastle.com My name is Ron Meckler and I am a planning consultant with Crown Castle for zoning and permitting services. Our client, Sprint PCS, is in the process of a national update and modernization of its wireless service. The project requires adding 3 antennas to an existing aray, No change to tower height or ground space. A summary of the work planned for this site is: • Install 2.5 equipment in existing cabinet • Add (3) Antennas(1 per sector) • Install (3) RRH units (1 per sector) • Install (6) Junction Cylinders (2 per sector) • Install (3) Filters THE HEIGHT OF THE EXISTING TOWER WILL NOT BE INCREASED, NOR WILL THE FOOTPRINT OF THE EXISTING EQUIPMENT COMPOUND BE CHANGED. Crown Castle is the owner and operator of the wireless facility at the above address. Crown Castle believes the existing structure will comply with all FAA regulations and applicable standards with the improvements and alterations proposed in this permit application. Furthermore, Crown Castle states that the proposed installation, repair, operation, upgrading, maintenance and removal of antennas shall be lawful and in compliance with all applicable laws, orders, ordinances and regulations of the state, and local authorities having jurisdiction. Crown Castle further agrees to remove the facility within one year after all of the site's tenants discontinue use of the facility or the facility falls into disrepair, and restore the site to its pre-existing condition. Thank you for your assistance. Sincerely, Ronald M k ' operty Specialist p Y P West Area rJ Date: December 20, 2013 Michael Murray Crown Castle 5350 North 48th Street, Suite 305 Chandler, AZ 85226 (480) 734-2422 Subject: Carrier Designation: Crown Castle Designation: Engineering Firm Designation: Site Data: Dear Michael Murray, Glaus, Pyle, Schomer, Burns & DeHaven, Inc., dba Glaus, Pyle, Schomer, Burns & DeHaven, PC 520 South Main Street, Suite 2531 Akron, OH 44311 (614) 859-1607 dpalkovic@gpdgroup.com Structural Analysis Report Sprint PCS Co -Locate Carrier Site Number: Carrier Site Name: Crown Castle BU Number: Crown Castle Site Name: Crown Castle JDE Job Number: Crown Castle Work Order Number: Crown Castle Application Number: Scenario 2.5B SE03XC408 TUKWILA 880338 TUKWILA 253287 686043 206598 Rev. 1 GPD Group Project Number: 2013777.880338.03 12400 51ST PL. S, TUKWILA, WA 98178, King County Latitude 47°29'37.52'; Longitude -122° 16' 14.19" 80 Foot — Valmont Monopole Tower Glaus, Pyle, Schomer, Burns & De Haven, Inc. dba Glaus, Pyle, Schomer, Burns & De Haven, PC (GPD Group) is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural `Statement of Work' and the terms of Crown Castle Purchase Order Number 602709, in accordance with application 206598, revision 1. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC7: Existing + Reserved + Proposed Equipment Sufficient Capacity Note: See Table I and Table II for the proposed and existing/reserved loading, respectively. This analysis has been performed in accordance with the 2012 International Building Code based upon an ultimate 3 -second gust wind speed of 110 mph converted to a nominal 3 -second gust wind speed of 85 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category C and Risk Category II were used in this analysis. We at GPD Group appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have anv auestions or need further assistance on this or any other projects please give us a call. EXP 01/16/15 Respectfully submitted by: John N. Kabak, S.E. 12/20/13 Washington #: 50892 520 South Main Street . Suite 2531 . Akron, Ohio 44311 . 330-572-2100. Fax 330-572-2101 . www.GPDGroup.com Glaus, Pyle, Schomer, Burns & De Haven, Inc. dba Glaus, Pyle, Schomer, Burns & De Haven, PC Crown Castle USA Inc 80 Ft Monopole Tower Structural Analysis Project Number 2013777.880338.03, Application 206598, Revision 1 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2 - Existing and Reserved Antenna and Cable Information Table 3 - Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Table 6 - Tower Components vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations tnxTower Report - version 6.1.3.1 December 20, 2013 CCI BU No 880338 Page 2 Crown Castle USA Inc 80 Ft Monopole Tower Structural Analysis Project Number 2013777.880338.03, Application 206598, Revision 1 1) INTRODUCTION December 20, 2013 CCI BU No 880338 Page 3 The existing tapered monopole tower has three major sections connected by slip joints. The tower has 12 sides and is evenly tapered from a 34.5" outer diameter at the base to a 19.5" outer diameter at the top. The structure is galvanized and has no tower lighting. The monopole was originally designed by Valmont Industries, Inc. of Valley, Nebraska in March of 1996. The tower was originally designed for an 85 mph basic wind speed with 1/2" radial ice in accordance with TIA/EIA- 222-E. 2) ANALYSIS CRITERIA This analysis has been performed in accordance with the 2012 International Building Code based upon an ultimate 3 -second gust wind speed of 110 mph converted to a nominal 3 -second gust wind speed of 85 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category C and Risk Category II were used in this analysis. Per section 2.6.4 of the TIA-222-G standard, ice loading may be ignored for structures located in regions where the design ice thickness is less than or equal to 0.25 inches (6 mm). Ice loading was not considered in this analysis. Seismic loads were determined from hand calculations. It was concluded from these calculations that the wind Toads control the maximum loading on the structure. The seismic loading case will not control. Refer to Appendix C for seismic calculations. Table 1 - Proposed Antenna and Cable Information Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) Note 2 Andrew HBXX-9014DS-A2M 3 7 KMW ET-X-WM-18-65-8P 1 I RFS Celwave APXVRR13-C-A20 r— 3 Samsung 2.5G 8T8R RADAR FILTER 77.0 77.0 [ 3 Samsung 2.5GHz RRH-V3 3 1-1/4 1 3 Samsung OPTIC FIBER JUNCTION CYLINDER 3 Samsung POWER JUNCTION CYLINDER 3 Samsung RRH-P4 otes• 1) See Appendix B for the proposed coax layout. tnxTower Report - version 6.1.3.1 Crown Castle USA Inc 80 Ft Monopole Tower Structural Analysis Project Number 2013777.880338.03, Application 206598, Revision 1 Table 2 - Existing and Reserved Antenna and Cable Information December 20, 2013 CCI BU No 880338 Page 4 Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) Note' - PSI Project #: 9704-4120, dated 05/28/1997 6 Dapa 58010 6 7/8 1 77.0 77.0- r - r I 1 1 F T -Arm Mount [TA 602-3] T I 66.0 2 Nokia FXFB 1 Raycap RNSDC-7771-PF-48 6 Andrew ECC1920-VPUB 1 1-1/4 2 61.0 6 Andrew ETT19V2S12UB 64.0 6 Andrew TMZXX-6516-A2M 3 Nokia FRIG 61.0 1 1 T -Arm Mount [TA 602-3] 12 7/8 34.0 34.0 1 Side Arm Mount [SO 701-1] 3 Notes: 1) Equipment to be removed and was not considered in the analysis. 2) Reserved equipment. 3) Empty mount. Table 3 - Design Antenna and Cable Information Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 97 97 80 80 Swedcom ALP 9212-N Platform Mount ALP 9212-N 1 3) ANALYSIS PROCEDURE Table 4 - Documents Provided Platform Mount Document Remarks Reference Source Original Tower Drawings/Specifications Foundation Drawings/Specifications Valmont Order #: 13475-96, dated 07/23/1996 Valmont Order #: 13505-96, dated 08/14/1996 Doc ID #: 1954920 Doc ID #: 1954919 T Doc ID #:1581821 Crown DMZ Crown DMZ _ I Crown DMZ Geotechnical Report PSI Project #: 9704-4120, dated 05/28/1997 Previous Structural Analysis GPD Project #: 2012775.880338.02, dated 12/18/2012 Doc ID #: 3403305 Crown DMZ 3.1) Analysis Method tnxTower (version 6.1.3.1), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. tnxTower Report - version 6.1.3.1 Crown Castle USA Inc 80 Ft Monopole Tower Structural Analysis Project Number 2013777.880338.03, Application 206598, Revision 1 3.2) Assumptions December 20, 2013 CCI BU No 880338 Page 5 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. 4) When applicable, transmission cables are considered as structural components for calculating wind Toads as allowed by TIA-222-G. 5) Mount sizes, weights, and manufacturers are best estimates based on site photos provided and were determined without the benefit of a site visit by GPD. 6) All member connections and foundation steel reinforcing are assumed designed to meet or exceed the load carrying capacity of the connected member and surrounding soils respectively unless otherwise specified in this report. 7) All equipment model numbers, quantities, and centerline elevations are as provided in the CCI CAD package dated 12/06/2013 with any adjustments as noted below. - There should only be (1) proposed 1-1/4" coax to 61 ft. listed on the base level drawing. This analysis may be affected if any assumptions are not valid or have been made in error. GPD Group should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Section No. Elevation (ft) Component Type Size Critical Element P (K) SF*P_allow (K) % Capacity Pass / Fail L1 80 - 56 Pole TP24.3x19.5x0.2188 1 -5.1680 1125.1700 11.6 Pass L2 56 - 27.4167 Pole TP29.58x23.0625x0.2813 i 2 -8.4859 1800.8900 24.0 Pass L3 27.4167 - 0 Pole TP34.5x28.1007x0.3125 3 T-13.4306 2333.4900 33.0 Pass T I Summary Pole (L3) ELC: 33.0 1 Load Case 7 Pass ] Pass - T Rating = 33.0 Table 6 - Tower Component Stresses vs. Capacity — LC7 Notes Component Elevation (ft) % Capacity Pass / Fail I Anchor Rods I Base Plate T Base Foundation I 0 30.4 17.2 32.1 _I r Pass Pass Pass Structure Rating (max from all components) = 33% Notes: 1) See additional documentation in "Appendix C - Additional Calculations" for calculations supporting the % capacity consumed. 2) Foundation capacity determined by comparing analysis reactions to original design reactions, considering a factor of 1.35 per TIA-222-G. 4.1) Recommendations The existing tower and its foundation are sufficient for the proposed loading and do not require modifications. tnxTower Report - version 6.1.3.1 6 -own Castle USA Inc 80 Ft Monopole Tower Structural Analysis Project Number 2013777.880338.03, Application 206598, Revision 1 5) DISCLAIMER OF WARRANTIES December 20, 2013 CCI BU No 880338 Page 6 GPD GROUP has not performed a site visit to the tower to verify the member sizes or antenna/coax loading. If the existing conditions are not as represented on the tower elevation contained in this report, we should be contacted immediately to evaluate the significance of the discrepancy. This is not a condition assessment of the tower or foundation. This report does not replace a full tower inspection. The tower and foundations are assumed to have been properly fabricated, erected, maintained, in good condition, twist free, and plumb. The engineering services rendered by GPD GROUP in connection with this Structural Analysis are limited to a computer analysis of the tower structure and theoretical capacity of its main structural members. All tower components have been assumed to only resist dead loads when no other loads are applied. No allowance was made for any damaged, bent, missing, loose, or rusted members (above and below ground). No allowance was made for loose bolts or cracked welds. GPD GROUP does not analyze the fabrication of the structure (including welding). It is not possible to have all the very detailed information needed to perform a thorough analysis of every structural sub -component and connection of an existing tower. GPD GROUP provides a limited scope of service in that we cannot verify the adequacy of every weld, plate connection detail, etc. The purpose of this report is to assess the feasibility of adding appurtenances usually accompanied by transmission lines to the structure. It is the owner's responsibility to determine the amount of ice accumulation in excess of the code specified amount, if any, that should be considered in the structural analysis. The attached sketches are a schematic representation of the analyzed tower. If any material is fabricated from these sketches, the contractor shall be responsible for field verifying the existing conditions, proper fit, and clearance in the field. Any mentions of structural modifications are reasonable estimates and should not be used as a precise construction document. Precise modification drawings are obtainable from GPD GROUP, but are beyond the scope of this report. Miscellaneous items such as antenna mounts, etc., have not been designed or detailed as a part of our work. We recommend that material of adequate size and strength be purchased from a reputable tower manufacturer. GPD GROUP makes no warranties, expressed and/or implied, in connection with this report and disclaims any liability arising from material, fabrication, and erection of this tower. GPD GROUP will not be responsible whatsoever for, or on account of, consequential or incidental damages sustained by any person, firm, or organization as a result of any data or conclusions contained in this report. The maximum liability of GPD GROUP pursuant to this report will be limited to the total fee received for preparation of this report. tnxTower Report - version 6.1.3.1 Crown Castle USA Inc 80 Ft Monopole Tower Structural Analysis Project Number 2013777.880338.03, Application 206598, Revision 1 APPENDIX A TNXTOWER OUTPUT tnxTower Report - version 6.1.3.1 December 20, 2013 CCI BU No 880338 Page 7 .-- N 32.00 32.58 \ 24.00 N N N c 4.00 19.5000 24.3000 A572-65 3.4 2.6 1.2 77 0.2813 m a 23.0625 29.5800 T -Arm Mount [TA 602-3] N N id HBXX-9014DS-A2M w/ Mount Pipe 28.1007 34.5000 Section Length (ft) Number of Sides_ Thickness (in) Socket Length (ft) 0 0 Fa Bot Dia (in) Grade Weight (K) 7.3 80.01t 56.0 27.4 ft 0.00 1 DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION T -Arm Mount [TA 602-3] 77 (3) Pipe Mount 4'x2.375" 77 APXVRRI3-C-A20 w/ Mount Pipe 77 (3) Pipe Mount 4'x2.375" 77 HBXX-90140S-A2M w/ Mount Pipe 77 T -Arm Mount [TA 602-3] 61 HBXX-9014DS-A2M w/ Mount Pipe 77 (2) TMZXX-6516-A2M w/ Mount Pipe 61 RRH-P4 77 (2) TMZXX-6516-A2M w/ Mount Pipe 61 RRH-P4 77 (2) TMZXX-6516-A2M w/ Mount Pipe 61 RRH-P4 77 (2) ETT19V2S12UB 61 ET-X-WM-18-65-8P w/ Mount Pipe 77 (2) ETT19V2S12UB 61 ET-X-WM-18-65-8P w/ Mount Pipe 77 (2) ETT19V2S12UB 61 ET-X-WM-18-65-8P w/ Mount Pipe 77 (2) ECC1920-VPUB 61 2.5GHz RRH-V3 77 (2) ECC1920-VPUB 61 2.5GHz RRH-V3 77 (2) ECC1920-VPUB 61 2.5GHz RRH-V3 77 FRIG 61 2.5G 8T8R RADAR FILTER 77 FRIG 61 2.5G 8T8R RADAR FILTER 77 FRIG 61 2.5G 8T8R RADAR FILTER 77 FXFB 61 OPTIC FIBER JUNCTION CYLINDER 77 FXFB 61 OPTIC FIBER JUNCTION CYLINDER 77 RNSDC-7771-PF-48 61 OPTIC FIBER JUNCTION CYLINDER 77 Pipe Mount 5'x2.375" 61 POWER JUNCTION CYLINDER 77 Pipe Mount 5'x2.375" 61 POWER JUNCTION CYLINDER 77 Pipe Mount 5'02.375" 61 POWER JUNCTION CYLINDER 77 Side Arm Mount [S0701-1] 34 (3) Pipe Mount 4x2.375" 77 MATERIAL STRENGTH GRADE Fy Fu GRADE 1 Fy Fu A572-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower is located in King County, Washington. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 85 mph basic wind in accordance with the TIA-222-G Standard. 4. Deflections are based upon a 60 mph wind. 5. Tower Structure Class II. 6. Topographic Category 1 with Crest Height of 0.00 ft 7. TOWER RATING: 33% ALL REACTIONS ARE FACTORED AXIAL 13K SHEAR MOMENT 10 K 527 kip -ft TORQUE 0 kip -ft REACTIONS - 85 mph WIND GPD Group 520 South Main Street, Suite 2531 GPD GROUP Akron, OH 44311 GPD Group Phone: (330) 572-2222 FAX: (330) 572-3722 job: TUKWILA - BU #: 880338 Project: 2013777.880338.03 Client: Crown Castle USA, Inc. Drawn by: bkelly App'd: Code: TIA-222-G Date 12/20/13 Scale: NTS Path: T.\Crawn\880338103\fiN880338.eri Dwg No E-1 80.00 Round Face A Feed Line Distribution Chart 0' - 80' Flat App In Face App Out Face Truss Leg 77.00 61.00 8.00 Face B Face C 80.00 77.00 61.00 8.00 (3) TYPE 1(1-1141 56.00 27.42 0.00 GPD Group /�, 520 South Main Street, Suite 2531 GPD GROUP Akron, OH 44311 GPD Group Phone: (330) 572-2222 FAX: (330) 572-3722 job: TUKWILA - BU #: 880338 Project: 2013777.880338.03 Client: Crown Castle USA, Inc. Drawn by: bkelly App'd: Code' TIA-222-G Date 12/20/13 Scale: NTS Path: T:1Crownt880338t010 01880338.0.1 Dwg No. E-7 tnxTower GPD Group 520 South Main Street, Suite 2531 Akron, OH 44311 Phone: (330)572-2222 FAX: (330) 572-3722 Job TUKWILA - BU #: 880338 Page 1 of 6 Project 2013777.880338.03 Date 13:56:34 12/20/13 Client Crown Castle USA, Inc. Designed by bkelly Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in King County, Washington. Basic wind speed of 85 mph. Structure Class II. Exposure Category C. Topographic Category 1. Crest Height 0.00 ft. Deflections calculated using a wind speed of 60 mph. A non-linear (P -delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments - Legs Consider Moments - Horizontals Consider Moments - Diagonals Use Moment Magnification Use Code Stress Ratios 4 Use Code Safety Factors - Guys Escalate Ice Always Use Max Kz Use Special Wind Profile Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) Add IBC .6D+W Combination Distribute Leg Loads As Uniform Assume Legs Pinned ) Assume Rigid Index Plate ▪ Use Clear Spans For Wind Area Use Clear Spans For KUr Retension Guys To Initial Tension Bypass Mast Stability Checks ▪ Use Azimuth Dish Coefficients J Project Wind Area of Appurt. Autocalc Torque Arm Areas SR Members Have Cut Ends Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Use TIA-222-G Tension Splice Capacity Exemption Treat Feedline Bundles As Cylinder Use ASCE 10 X -Brace Ly Rules Calculate Redundant Bracing Forces Ignore Redundant Members in FEA SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation Consider Feedline Torque Include Angle Block Shear Check Poles Include Shear -Torsion Interaction Always Use Sub -Critical Flow Use Top Mounted Sockets Tapered Pole Section Geometry Section Elevation ft Section Length ft Splice Length ft Number Top Bottom Wall of Diameter Diameter Thickness Sides in in in Bend Radius in Pole Grade LI 80.00-56.00 24.00 L2 56.00-27.42 32.58 4.00 12 19.5000 24.3000 4.58 12 23.0625 29.5800 L3 27.42-0.00 32.00 12 28.1007 34.5000 0.2188 0.2813 0.3125 0.8750 1.1250 1.2500 A572-65 (65 ksi) A572-65 (65 ksi) A572-65 (65 ksi) tnxTower GPD Group 520 South Main Street, Suite 2531 Akron, OH44311 Phone: (330) 572-2222 FAX: (330) 572-3722 Job TUKWILA - BU #: 880338 g Pa e 2 of 6 Project 2013777.880338.03 Date 13:56:34 12/20/13 Client Crown Castle USA, Inc. Designed by bkelly Tapered Pole Properties Section Tip Dia. Area 1 inz in° in r in in 1/C in3 J in° It/Q int w in w/t Ll 20.1879 13.5812 644.4592 6.9027 10.1010 63.8015 1305.8491 6.6843 4.6398 21.21 25.1572 16.9622 1255.5296 8.6211 12.5874 99.7450 2544.0434 8.3483 5.9261 27.091 L2 24.7044 20.6313 1366.6805 8.1557 11.9464 114.4013 2769.2653 10.1541 5.4270 19.296 30.6235 26.5337 2907.2450 10.4890 15.3224 189.7377 5890.8665 13.0591 7.1737 25.506 L3 30.0409 27.9619 2755.9677 9.9482 14.5562 189.3332 5584.3377 13.7620 6.6935 21.419 35.7170 34.4012 5132.0854 12.2391 17.8710 287.1739 10398.9964 16.9312 8.4085 26.907 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Sector Component Placement Type ft Total Number Start/End Width or Perimeter Weight Number Per Row Position Diameter in in plf Step Pegs Safety Line (3/8") *** C Surface Ar 80.00 - 8.00 1 1 -0.250 0.8000 (CaAa) 0.250 C Surface Ar 80.00 - 8.00 1 1 0.000 0.3750 (CaAa) 0.000 2.72 0.22 Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement or Shield Type Leg ft Total Number CAAA ft2/ft Weight plf LDF5-50A(7/8") A No Inside Pole 61.00 - 8.00 12 No Ice 0.00 ASU9323TYP01( 1-1/4) A No Inside Pole 61.00 - 8.00 1 No Ice 0.00 TYPE 1(1-1/4") C No Inside Pole 77.00 - 8.00 3 No Ice 0.00 *** 0.33 1.05 0.50 Discrete Tower Loads Description Face Offset Offsets: Azimuth or Type Horz Adjustment Leg Lateral Placement Vert ft ft ft ft CAAA Front CAAA Side ft2 ft' Weight K T -Arm Mount [TA 602-3] C None 0.0000 77.00 No Ice 11.59 11.59 0.7743 APXVRR13-C-A20 w/ A From Leg 4.00 0.0000 77.00 No Ice 7.69 4.03 0.0539 Mount Pipe 0.00 0.00 HBXX-9014DS-A2M w/ B From Leg 4.00 0.0000 77.00 No Ice 6.36 4.71 0.0517 Mount Pipe 0.00 0.00 HBXX-9014DS-A2M w/ C From Leg 4.00 0.0000 77.00 No Ice 6.36 4.71 0.0517 Mount Pipe 0.00 0.00 RRH-P4 A From Leg 4.00 0.0000 77.00 No Ice 3.19 2.07 0.0595 0.00 0.00 RRH-P4 B From Leg 4.00 0.0000 77.00 No Ice 3.19 2.07 0.0595 0.00 0.00 RRH-P4 C From Leg 4.00 0.0000 77.00 No Ice 3.19 2.07 0.0595 0.00 GPD Group 520 South Main Street, Suite 2531 Akron, OH 44311 Phone: (330)572-2222 FAX: (330) 572-3722 Job °b TUKWILA - BU #: 880338 Page 3 of 6 Project 2013777.880338.03 Date 13:56:34 12/20/13 Client Crown Castle USA, Inc. Designed by bkelly Description Face Offset Offsets: Azimuth Placement or Type Horz Adjustment Leg Lateral Vert ftt ft ft CAAA Front CAAA Side Weight K 0.00 ET-X-WM-18-65-8P w/ A From Leg 4.00 0.0000 77.00 No Ice 7.35 4.43 0.0586 Mount Pipe 0.00 0.00 ET-X-WM-18-65-8P w/ B From Leg 4.00 0.0000 77.00 No Ice 7.35 4.43 0.0586 Mount Pipe 0.00 0.00 ET-X-WM-I8-65-8P w/ C From Leg 4.00 0.0000 77.00 No Ice 7.35 4.43 0.0586 Mount Pipe 0.00 0.00 2.5GHz RRH-V3 A From Leg 4.00 0.0000 77.00 No Ice 2.80 1.42 0.0595 0.00 0.00 2.5GHz RRH-V3 B From Leg 4.00 0.0000 77.00 No Ice 2.80 1.42 0.0595 0.00 0.00 2.5GHz RRH-V3 C From Leg 4.00 0.0000 77.00 No Ice 2.80 1.42 0.0595 0.00 0.00 2.5G 8T8R RADAR FILTER A From Leg 4.00 0.0000 77.00 No Ice 0.94 0.35 0.0220 0.00 0.00 2.5G 8T8R RADAR FILTER B From Leg 4.00 0.0000 77.00 No Ice 0.94 0.35 0.0220 0.00 0.00 2.5G 8T8R RADAR FILTER C From Leg 4.00 0.0000 77.00 No Ice 0.94 0.35 0.0220 0.00 0.00 OPTIC FIBER JUNCTION A From Leg 4.00 0.0000 77.00 No Ice 0.45 0.45 0.0020 CYLINDER 0.00 0.00 OPTIC FIBER JUNCTION B From Leg 4.00 0.0000 77.00 No Ice 0.45 0.45 0.0020 CYLINDER 0.00 0.00 OPTIC FIBER JUNCTION C From Leg 4.00 0.0000 77.00 No Ice 0.45 0.45 0.0020 CYLINDER 0.00 0.00 POWER JUNCTION A From Leg 4.00 0.0000 77.00 No Ice 0.43 0.43 0.0033 CYLINDER 0.00 0.00 POWER JUNCTION B From Leg 4.00 0.0000 77.00 No Ice 0.43 0.43 0.0033 CYLINDER 0.00 0.00 POWER JUNCTION C From Leg 4.00 0.0000 77.00 No Ice 0.43 0.43 0.0033 CYLINDER 0.00 0.00 (3) Pipe Mount 4'x2.375" A From Leg 4.00 0.0000 77.00 No Ice 0.87 0.87 0.0185 0.00 0.00 (3) Pipe Mount 4'x2.375" B From Leg 4.00 0.0000 77.00 No Ice 0.87 0.87 0.0185 0.00 0.00 (3) Pipe Mount 4'x2.375" C From Leg 4.00 0.0000 77.00 No Ice 0.87 0.87 0.0185 0.00 0.00 T -Arm Mount [TA 602-3] C None 0.0000 61.00 No Ice 11.59 11.59 0.7743 (2) TMZXX-6516-A2M w/ A From Leg 4.00 0.0000 61.00 No Ice 5.94 4.15 0.0508 Mount Pipe 0.00 tnxTower GPD Group 520 South Main Street, Suite 2531 Akron, OH44311 Phone: (330) 572-2222 FAX: (330) 572-3722 Job TUKWILA - BU #: 880338 Page 4 of 6 Project 2013777.880338.03 Date 13:56:34 12/20/13 Client Crown Castle USA, Inc. Designed by bkelly Description Face Offset Offsets: Azimuth Placement or Type Horz Adjustment Leg Lateral Vert ft ft ft ft CAAA CAAA Weight Front Side ft2 ft2 K 3.00 (2) TMZXX-6516-A2M w/ B From Leg 4.00 0.0000 61.00 No Ice 5.94 4.15 0.0508 Mount Pipe 0.00 3.00 (2) TMZXX-6516-A2M w/ C From Leg 4.00 0.0000 61.00 No Ice 5.94 4.15 0.0508 Mount Pipe 0.00 3.00 (2) ETT19V2SI2UB A From Leg 4.00 0.0000 61.00 No Ice 0.67 0.32 0.0139 0.00 3.00 (2) ETT19V2S12UB B From Leg 4.00 0.0000 61.00 No Ice 0.67 0.32 0.0139 0.00 3.00 (2) ETT19V2S12UB C From Leg 4.00 0.0000 61.00 No Ice 0.67 0.32 0.0139 0.00 3.00 (2) ECC1920-VPUB A From Leg 4.00 0.0000 61.00 No Ice 0.54 0.21 0.0080 0.00 3.00 (2) ECC1920-VPUB B From Leg 4.00 0.0000 61.00 No Ice 0.54 0.21 0.0080 0.00 3.00 (2) ECC1920-VPUB C From Leg 4.00 0.0000 61.00 No Ice 0.54 0.21 0.0080 0.00 3.00 FRIG A From Leg 4.00 0.0000 61.00 No Ice 2.79 1.10 0.0573 0.00 3.00 FRIG B From Leg 4.00 0.0000 61.00 No Ice 2.79 1.10 0.0573 0.00 3.00 FRIG C From Leg 4.00 0.0000 61.00 No Ice 2.79 1.10 0.0573 0.00 3.00 FXFB A From Leg 4.00 0.0000 61.00 No Ice 0.99 1.12 0.0551 0.00 5.00 FXFB B From Leg 4.00 0.0000 61.00 No Ice 0.99 1.12 0.0551 0.00 5.00 RNSDC-7771-PF-48 A From Leg 4.00 0.0000 61.00 No Ice 3.71 1.38 0.0200 0.00 5.00 Pipe Mount 5'x2.375" A From Leg 4.00 0.0000 61.00 No Ice 1.19 1.19 0.0223 0.00 0.00 Pipe Mount 5'x2.375" B From Leg 4.00 0.0000 61.00 No Ice 1.19 1.19 0.0223 0.00 0.00 Pipe Mount 5'x2.375" C From Leg 4.00 0.0000 61.00 No Ice 1.19 1.19 0.0223 0.00 0.00 Side Arm Mount (SO 701-1) B From Leg 1.00 0.0000 34.00 No Ice 0.85 1.67 0.0650 0.00 0.00 tnxTower GPD Group 520 South Main Street, Suite 2531 Akron, OH 44311 Phone: (330) 572-2222 FAX: (330) 572-3722 Job TUKWILA - BU #: 880338 Page 5 of 6 Project 2013777.880338.03 Date 13:56:34 12/20/13 Client Crown Castle USA, Inc. Designed by bkelly Maximum Tower Deflections - Service Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt Twist L1 L2 L3 80-56 60 - 27.4167 32-0 4.424 2.711 0.839 26 26 32 0.4191 0.3844 0.2308 0.0004 0.0005 0.0002 Critical Deflections and Radius of Curvature - Service Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt Twist 77.00 T -Arm Mount [TA 602-3] 26 61.00 T -Arm Mount [TA 602-3] 26 34.00 Side Arm Mount [SO 701-1] 32 4.161 2.793 0.935 0.4161 0.3875 0.2443 0.0005 0.0005 0.0002 Radius of Curvature ft 77383 20155 6741 Maximum Tower Deflections - Design Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt Twist L1 L2 L3 80-56 60 - 27.4167 32-0 15.917 9.757 3.019 2 2 14 1.5078 1.3827 0.8306 0.0016 0.0018 0.0008 Critical Deflections and Radius of Curvature - Design Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt Twist 77.00 T -Arm Mount [TA 602-3] 61.00 T -Arm Mount [TA 602-3] 34.00 Side Arm Mount [SO 701-1] 2 2 14 14.971 10.051 3.366 1.4969 1.3939 0.8795 0.0017 0.0019 0.0009 Radius of Curvature ft 21591 5622 1874 Compression Checks Pole Design Data Section Elevation No. ft Size L L Kl/r A ft ft P„ it? K Ratio Pu K 4)P. Ll 80 - 56 (1) TP24.3x19.5x0.2188 24.00 0.00 0.0 16.3987 -5.1680 1125.1700 0.005 L2 56 - 27.4167 TP29.58x23.0625x0.2813 32.58 0.00 0.0 25.7034 -8.4859 1800.8900 0.005 (2) L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 32.00 0.00 0.0 34.4012 -13.4306 2333.4900 0.006 tnxTower GPD Group 520 South Main Street, Suite 2531 Akron, OH 44311 Phone: (330) 572-2222 (330) 572-3722 TUKWILA - BU #: 880338 Page g e 6 of 6 Project 2013777.880338.03 Date 13:56:34 12/20/13 Client Crown Castle USA, Inc. Designed by bkelly y Pole Bending Design Data Section Elevation No. ft Size M� �N1„r Ratio M„„ kip ft kip ft $M kip ft kip ft M. coM„y Ratio M„,, LI 80 - 56 (1) TP24.3x19.5x0.2188 59.29 532.89 0.111 0.00 532.89 0.000 L2 56 - 27.4167 TP29.58x23.0625x0.2813 244.19 1039.25 0.235 0.00 1039.25 0.000 (2) L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 526.50 1623.29 0.324 0.00 1623.29 0.000 Pole Shear Design Data Section Elevation No. ft Size Actual V K OV„ K Ratio Actual V T 4V kip ft 4T kip ft Ratio T LI 80 - 56 (1) TP24.3x19.5x0.2188 5.5889 562.5850 0.010 0.14 L2 56 - 27.4167 TP29.58x23.0625x0.2813 7.6971 900.4430 0.009 0.24 (2) L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 9.9242 1161.0400 0.009 0.24 1080.53 2107.28 OT 0.000 0.000 3291.53 0.000 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. No. P„ M,,r M„, V„ T Stress Stress ft OP„ OM.. eine. IfpV OT Ratio Ratio LI 80 - 56 (1) 0.005 0.111 0.000 0.010 0.000 0.116 1.000 L2 56 - 27.4167 0.005 0.235 0.000 0.009 0.000 0.240 1.000 (2) V L3 27.4167 - 0 (3) 0.006 0.324 0.000 0.009 0.000 0.330 1.000 r Criteria 4.8.2 V 4.8.2 V 4.8.2 V/ Section Capacity Table Section No. Elevation ft Component Type Size Critical P Element K OP„n„,,. Pass K Capacity Fail LI 80 - 56 Pole TP24.3x19.5x0.2188 1 -5.1680 1125.1700 11.6 Pass L2 56 - 27.4167 Pole TP29.58x23.0625x0.2813 2 -8.4859 1800.8900 24.0 Pass L3 27.4167 - 0 Pole TP34.5x28.1007x0.3125 3 -13.4306 2333.4900 33.0 Pass Summary ELC: Load Case 7 Pole (L3) 33.0 Pass Rating = 33.0 Pass Crown Castle USA Inc 80 Ft Monopole Tower Structural Analysis Project Number 2013777.880338.03, Application 206598, Revision 1 APPENDIX B BASE LEVEL DRAWING tnxTower Report - version 6.1.3.1 December 20, 2013 CCI BU No 880338 Page 8 way 1 ma IWO a1 amain D//nl+t n mp sd W ass IdDDsa t7V1 t D/WD caw 1 a10 ru lolano IomIIIw a/II/n _. 1 mo >o d aanon 1111/IosD led 10M10/11 TMnus 11110/_% No✓1 m mD Eta a1 ®I ID1ato 11Fb dOVW alai / asD ma W wan mhl/n M 0011 1 MD IMO — it 0D 1sDs1 10.44//1 Y Man / 111)20 MN a1 alias all .1.1. a ga' go m�i opo W 0. 1 s 9 BASE LEVEL DRAWING 4 Crown Castle USA Inc 80 Ft Monopole Tower Structural Analysis Project Number 2013777.880338.03, Application 206598, Revision 1 APPENDIX C ADDITIONAL CALCULATIONS tnxTower Report - version 6.1.3.1 December 20, 2013 CCI BU No 880338 Page 9 L. Stiffened or Unstiffened, Ungrouted, Circular Base Plate - Any Rod Material Assumption: Clear space between bottom of leveling nut and top of concrete not exceeding (1)*(Rod Diameter) TIA Rev G Site Data BU#: 880338 Site Name: TUKWILA App #: 206598 Rev. 1 Pole Manufacturer:I Other Anchor Rod Data Qty: 8 in Diam: 2.25 in Rod Material: A615 -J ksi Strength (Fu): 100 ksi Yield (Fy): 75 ksi Bolt Circle: 42.22 in Plate Data Diam: 48.22 in Thick: 2.375 in Grade: 60 ksi Single -Rod B-eff: 13.87 in Stiffener Data (Welding at both sides) Config: Weld Type: Groove Depth: Groove Angle: Fillet H. Weld: 0 * in ** degrees <-- Disregard in in in in in ksi ksi Thick: 0.3125 in Grade: Fillet V. Weld: ksi Width: Height: Thick: Notch: Grade: Weld str.: 12 „0„ IF Round Fu 80 ksi Reinf. Fillet Weld Pole Data Diam: 34.5 in Thick: 0.3125 in Grade: 65 ksi # of Sides: 12 „0„ IF Round Fu 80 ksi Reinf. Fillet Weld 0 "0" if None Reactions Mu: 527 ft -kips Axial, Pu: 13 kips Shear, Vu: 10 kips Eta Factor, q 0.5 TIA G (Fig. 4-4) If No stiffeners, Criteria: AISC LRFD Anchor Rod Results Max Rod (Cu+ Vu/q): Allowable Axial, *Fu*Anet: Anchor Rod Stress Ratio: Base Plate Results Base Plate Stress: Allowable Plate Stress: Base Plate Stress Ratio: <-Only Applcable to Unstiffened Cases 79.0 Kips 260.0 Kips 30.4% Pass Flexural Check 9.3 ksi 54.0 ksi 17.2% Pass n/a Stiffener Results Horizontal Weld : n/a Vertical Weld: n/a Plate Flex+Shear, fb/Fb+(fv/Fv)^2: n/a Plate Tension+Shear, ft/Ft+(fv/Fv)^2 n/a Plate Comp. (AISC Bracket): n/a Pole Results Pole Punching Shear Check: n/a 0 0 0 * 0 = none, 1 = every bolt, 2 = every 2 bolts, 3 = 2 per bolt '* Note: for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes Rigid AISC LRFD cp*Tn Rigid AISC LRFD cp*Fy Y.L. Length: 24.34 CCIplate 1.5 - Circular Base G 1.3, Effective March 19, 2012 Analysis Date: 12/20/2013 FOUNDATION REACTION COMPARISON BU #: 880338 WO#: 686043 REACTIONS DESIGN REACTIONS CURRENT REACTIONS % CAPACITY MOMENT (ft -kips) 1643.5 527 32.1 Notes: 1) Design reactions from CCIsites - Doc ID #: 1954920 2) Design reactions considering a factor of 1.35 per Section 15.5 of TIA-222-G. Seismic Calculations (TIA-222-G) Analysis Method: Equivalent Modal Analysis, Method 2 (Section 2.7.8, TIA-222-G) GPD Job Number 2013777.880338.03 Site Name TUKWILA Site Number 880338 City Tukwila State Washington County King Tower Type Monopole Base OD 34.5 in Base Thickness 0.3125 in # of Sides 12 Structure Height (ft) 80 Top OD Top Thickness Structure Classification 11 (Table 2-1, TIA-222-G) Importance Factor (I) 1 (Table 2-3, TIA-222-G) S1 0.562 (USGS, 2012 IBC) Ss 1.499 (USGs, 2012 IBC) Site Classification D (Table 2-11, TIA-222-G) Fa 1.000 (Table 2-12, TIA-222-G, interpolation allowed) Fv 1.500 (Table 2-13, TIA-222-G, interpolation allowed) $Dg 0.999 (Eq. 2.7.6, TIA-222-G) SD1 0.562 (Eq. 2.7.6, TIA-222-6) Wt 11.058 (Kips) Wu 2.980 (Kips) WL 8.078 (Kips) g 386.1 (in's�) I,� 2892.34 (in) E 29000.00 (ksi) f1 R SA Earthquake LRFD Load Factor Discrete Appurtenances Appurtenances @ 77' Appurtenances @ 61' Appurtenances @ 34' Linear Appurtenances Coax from 56' - 80' Coax from 27.42' - 56' Coax from 0' - 27.42' Structure Components Tower Section from 56' - 80' Tower Section from 27' - 56' Tower Section from 0' - 27' Totals 0.754 (Eq. 2.7.11, TIA-222-G) 1.5 (2.7.8.1, TIA-222-G) 0.424 (2.7.8.1, TIA-222-G) 1 (2.3.2, TIA-222-G) w ki s 19.5 in 0.21875 in Service Level S„ F� Seismic Forces 1.520 1.460 0.060 77 61 34 1.581 0.210 0.222 1.6016 0.2046 0.0089 1.602 kips 0.205 kips 0.009 kips 0.187 0.342 0.232 68 41.71 13.71 0.615 0.165 0.173 0.0767 0.0375 0.0267 0.077 kips 0.037 kips 0.027 kips 1.247 2.615 81 3.395 11.05 68 41.71 13.71 0.615 0.165 0.173 0.5114 0.2868 0.3912 0.511 kips 0.287 kips 0.391 kips "The service level seismic forces in the table above were input into a supplemental tnxTower analysis as "user defined loads". The resulting tower stress capacity ratings are in the table below** 3.15 315 kips Tower Stress Capacity Comparison Structure Components Capacity Considering Seismic Loading Capacity Considering Wind Loading Controlling Tower Section from 56' - 80' Tower Section from 27.42' - 56' Tower Section from 0' - 27.42' 6.6% 11.6% Wind 10.5% 24.0% Wind 12.8% 33.0% Wind Overall Controlling Load:' sx Wind Overall Capacity:, 33.0 NUl 7 ONg N / / 1 . i N � r N O 4.00 v 19.5000 24.3000 V9 N a rD (V M 68 a7 N O O N v 23.0625 29.5800 N O Appurtenances @ 61' 28.1007 34.5000 a r O J Number of Sides Thickness (in) Socket Length (11) - 6 H O O m D C7 Weight (K) 7.3 80.0 ft 56.0 ft 27.4 ft 0.00 O ALL REACTIONS ARE FACTORED AXIAL 13K SHEAR MOMENT 3 K I J 198 kip -ft REACTIONS - 1 mph WIND DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION Appurtenances @ 77' 77 Tower Section from 27' - 56' 41.71 Coax from 56' - 80' 68 Appurtenances @ 34' 34 Tower Section from 56' - 80' 68 Coax from 0' - 27.42' 13.71 Appurtenances @ 61' 61 Tower Section from 0' - 27' 13.71 Coax from 27.42' - 56' 41.71 MATERIAL STRENGTH GRADE Fy Fu GRADE 1 Fy Fu A572-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower is located in King County, Washington. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 1 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower Structure Class II. 5. Topographic Category 1 with Crest Height of 0.00 ft 6. TOWER RATING: 12.8% GPD Group /�, 520 South Main Street, Suite 2531 GPD GROUP Akron, OH 44311 GPD Group Phone: (330) 572-2222 FAX: (330) 572-3722 job: TUKWILA - BU #: 880338 Project: 2013777.880338.03 Client: Crown Castle USA, Inc. Drawn by: bkelly App'd: Code: TIA-222-G Date: 12/20/13 Scale: NTS Path: T:\Crown\880338\03\tnx\880338 seismic eri Dwg No. E-1 NbMIND tnxTower GPD Group 520 South Main Street, Suite 2531 Akron, OH 44311 Phone: (330) 572-2222 FAX: (330) 572-3722 Job TUKWILA - BU #: 880338 g Pa e 1 of 3 Project 2013777.880338.03 Date 14:29:44 12/20/13 Client Crown Castle USA, Inc. Designed by bkelly Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in King County, Washington. A non-linear (P -delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments - Legs Consider Moments - Horizontals Consider Moments - Diagonals Use Moment Magnification ) Use Code Stress Ratios 4 Use Code Safety Factors - Guys Escalate Ice Always Use Max Kz Use Special Wind Profile Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) Add IBC .6D+W Combination Distribute Leg Loads As Uniform Assume Legs Pinned J Assume Rigid Index Plate 4 Use Clear Spans For Wind Area Use Clear Spans For KUr Retension Guys To Initial Tension Bypass Mast Stability Checks i Use Azimuth Dish Coefficients Ai Project Wind Area of Appurt. Autocalc Torque Arm Areas SR Members Have Cut Ends Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Use TIA-222-G Tension Splice Capacity Exemption Treat Feedline Bundles As Cylinder Use ASCE 10 X -Brace Ly Rules Calculate Redundant Bracing Forces Ignore Redundant Members in FEA SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation Consider Feedline Torque Include Angle Block Shear Check Poles Ai Include Shear -Torsion Interaction Always Use Sub -Critical Flow Use Top Mounted Sockets User Defined Loads Description Elevation ft Offset Azimuth From Angle Centroid ft Weight F F, Seismic CAAc Force K K K K ft2 Appurtenances @ 77' Appurtenances @ 61' Appurtenances @ 34' Coax from 56' - 80' Coax from 27.42' - 56' Coax from 0' - 27.42' *** Tower Section from 56' - 80' Tower Section from 27' - 56' Tower Section from 0' - 27' *** 77.00 61.00 34.00 68.00 41.71 13.71 68.00 41.71 13.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 No Ice No Ice No Ice No Ice No Ice No Ice No Ice No Ice No Ice 1.5200 1.4600 0.0600 0.1871 0.3416 0.2320 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0010 0.1279 0.0055 0.0480 0.0234 0.0167 0.3197 0.1793 0.2445 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4._$ ..., tnxTower GPD Group 520 South Main Street, Suite 2531 Akron, OH44311 Phone: (330) 572-2222 FAX: (330) 572-3722 Job TUKWILA - BU #: 880338 Page 2 of 3 Project 2013777.880338.03 Date 14:29:44 12/20/13 Client Crown Castle USA, Inc. Designed by bkelly Maximum Tower Deflections - Seismic Section No. Elevation ft Horz. Gov. Deflection Load in Comb. Tilt Twist LI L2 L3 80 - 56 60 - 27.4167 32-0 6.603 3.940 1.174 8 8 8 0.6577 0.5834 0.3287 0.0000 0.0000 0.0000 Critical Deflections and Radius of Curvature - Seismic Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt Twist Radius of Curvature ft 77.00 68.00 61.00 41.71 34.00 13.71 Appurtenances @ 77' Coax from 56' - 80' Appurtenances @ 61' Coax from 27.42' - 56' Appurtenances @ 34' Coax from 0' - 27.42' 8 8 8 8 8 4 6.191 4.971 4.065 1.944 1.313 0.336 0.6499 0.6219 0.5893 0.4296 0.3497 0.1395 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 35958 14982 9509 5248 4506 10032 Compression Checks Pole Design Data Section Elevation No. ft Size L L Kl/r A ft ft P„ in2 K OP„ K Ratio P. 4P„ Ll 80 - 56 (1) TP24.3x19.5x0.2188 24.00 0.00 0.0 16.3987 -4.9999 1125.1700 0.004 L2 56 - 27.4167 TP29.58x23.0625x0.2813 32.58 0.00 0.0 25.7034 -8.4117 1800.8900 0.005 (2) L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 32.00 0.00 0.0 34.4012 -13.2691 2333.4900 0.006 Pole Bending Design Data Section Elevation No. ft Size At, kip ft kip ft Ratio M� $N1,� M„, kip ft kip ft Ratio M (PM„„ LI 80 - 56 (1) TP24.3x19.5x0.2188 32.65 532.89 0.061 0.00 532.89 0.000 L2 56 - 27.4167 TP29.58x23.0625x0.2813 104.37 1039.25 0.100 0.00 1039.25 0.000 (2) L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 198.41 1623.29 0.122 0.00 1623.29 0.000 4,4 tnxTower GPD Group 520 South Main Street, Suite 2531 Akron, OH44311 Phone: (330) 572-2222 (330) 572-3722 Job TUKWILA - BU #: 880338 Page 9 3 of 3 Project 2013777.880338.03 Date 14:29:44 12/20/13 Client Crown Castle USA, Inc. Designed by bkelly y Pole Shear Design Data Section Elevation No. ft Size Actual Vu K $V K Ratio Actual VT„ qV kip ft kip ft Ratio T LI 80 - 56 (1) TP24.3x19.5x0.2188 2.4460 562.5850 0.004 0.00 1080.53 L2 56 - 27.4167 TP29.58x23.0625x0.2813 2.7775 900.4430 0.003 0.00 2107.28 (2) L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 3.1483 1166.7400 0.003 0.00 3291.53 0.000 4T 0.000 0.000 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. No. P M, , M„. V„ T Stress Stress ft OP„ 01C $M„,. (1)11„ T Ratio Ratio Criteria LI 80 - 56 (1) 0.004 0.061 0.000 0.004 0.000 0-.0666 1.000 1 L2 56 - 27.4167 0.005 0.100 0.000 0.003 0.000 0.105 1.000 (2) Vi L3 27.4167 - 0 (3) 0.006 0.122 0.000 0.003 0.000 0.128 1.000 4.8.2 V/ 4.8.2 .✓ Y 4.8.2 ' Section Capacity Table Section No. Elevation ft Component Type Size Critical P Element K 4P„uo» K % Pass Capacity Fail LI 80 - 56 Pole TP24.3x19.5x0.2188 1 -4.9999 1125.1700 6.6 Pass L2 56 - 27.4167 Pole TP29.58x23.0625x0.2813 2 -8.4117 1800.8900 10.5 Pass L3 27.4167 - 0 Pole TP34.5x28.1007x0.3125 3 -13.2691 2333.4900 12.8 Pass Summary Pole (L3) 12.8 Pass RATING = 12.8 Pass 0400 TO: City of Tukwila Department of Community Development File Number IL14-0018 LAND USE PERMIT ROUTING FORM Building Planning ❑ Public Works 101 Fire Dept. IDI Police Dept. 10 Parks/Rec Project: Sprint 2.5 Wireless Facility Address: 12200 51st PI. S Date transmitted: 3/11/2014 Response requested by: 3/25/2014 Staff coordinator: Max Baker Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Plannung review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60 -day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) Plan check date: Comments prepared b Update date: 0400 City of Tukwila Department of Community Development RECEIVED MAR 112014 TUKWILA PUBLIC WORKS File Number L14-0018 LAND USE PERMIT ROUTING FORM TO: IDS Building Planning Public Works Fire Dept. 0 Police Dept. Parks/Rec Project: Sprint 2.5 Wireless Facility Address: 12200 51st PI. S Date transmitted: 3/11/2014 Response requested by: 3/25/2014 Staff coordinator: Max Baker Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60 -day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) P() hQs no ce2v1 vv1 e45 Plan check date:. 03/12/14 Comments / prepared by: JO�14JtVQ., Update date: STATE OF TEXAS COUNTY OF TARRANT CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX: (206) 431-3665 E-mail: planning(a.,TukwilaWA.gov AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY ss The undersigned being duly sworn and upon oath states as follows: _ BNSF Railway Company is j f' 1. the current owner of the property which is the subject of this application. "14.""I 2. All statements contained in the applications have been prepared by me or my agents and '"e true and correct to the best of my knowledge. 3. The application is beim submitted with my knowledge and consent. has authorized Lessee, Sprint Spectrum, through Crown Castle USA to 4. Owner�granV the City, its employees, agents, engineers, contractors or other representatives the right to enter upon Owner's real property, located at 12200 51' PL S, Tukwila, WA 98178 for the purpose of application."'" review, for the limited time necessary to complete that purpose. E!VED MAR 10 2014 EDEVLLU1'MENT J�- 5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the City's entry upon the property, unless the loss or damage is the result of theeaiir negligence of the City. 6. Non -responsiveness to a City intbrmation request for ninety (90) or more days, shall be cause to cancel the application(s) without refund of fees. � J_ EXECUTED at /'D (f (� Jk P i///n (city), 5C (state), on Se�07I•vh bee- 2 S , 20 / Z Dennis Auge — Director, BNSF Railway Company I (i is (Print Name) 2400 Western Center Blvd, Ft Worth, TX 76131 (Address) (817) 352-0206 On this day personally appeared before me Dennis Auge to me known to be the individual who executed the foregoing instrument and acknowledged that he/she signed the same as bislher voluntary act and deed for the uses and purposes mentioned therein. // -- SUBSCRIBED AND SWORN TO BEFORE ME ON THIS Z. DAY OF — 2�11-er, , 20 %Z 47rof of/My Comm. Exp. 05114/2014 DALEN E WINTERMUTE Notary Public STATE OF TEXAS NOTAR ' UBLIC in and for the State of iiirsoloingte+ Texas residing at 7 Lakeview Dr., Trophy Club, TX 76262 My Commission expires on 05/14/2014 H:\Land Use Applications in PDF\Wneless Communication Facility-Jan26l1.doc COMPLETE APPLICATION CHECKI,1ST The materials listed below must be submitted with your application unless specifically waived in writing the Department of Community Development. Please contact each Department if you feel that certain items are not applicable to your project and should be waived. Application review will not begin until it is determined to be complete. ADDITIONAL MATERIALS MAY BE REQUIRED. The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require additional information as needed to establish consistency with development standards. City staff are available to answer questions about application materials at 206-431-3670 (Department of Community Development) and 206-433-0179 (Department of Public Works). ti t'�ri t 'moi, el 1101 ,$f. 5( Iltll1c.�1 1.. r'},SL 4:41;z,,, 1� ' F� >4{'Zrfi kA �if '4 'rt Z v'. I4 ��V IIn ;i T�iw i.. a '.ai i) Tj I 1 �* ,,,/' 11' I�i!. �i5'Ii F'�� 3�F S �i�j'�f i!Ge[.. �, r ` s '41 � -rtiTy ��,+G�.^ '.� l.' x°P` F' _' c. YtA �%r '.w ."'} �J .1�'x, ... tl�dt r•.. '�&', h... r -aq �' ..'• �: x ;ii �J$j3Jjr t . {p ._ },,(l �,. �, tl,SyH' ,P}}y .: "a )N * S' ? y• tl H �; -1 �^ `,{{j����q p'S �. rFi�lF 9�f'l'�ia�`. A�. 1 }�R 1i r f tl A / f �4Fk `! !� ''Y� ,NM1'¢}t �'Cq [1. "�^j'.jgt ��'•'i ?. ry r'y- t�(.Y�y�N t4 th$ , F.l � s1`� ji 3ti .•�i Yi 4 J t 11s»y., ?,,C, aY' {7 ' �3")) c'I s' .�s -T • } F$1 !V'}" A 1 - of1}�j.F% •. �..' �R`h ! � �. M "4 �1..J �".1 "Q i I,jL .i i ns..�,'�.9t''4^. r. .' i... .t a.,: .. .#:-_s"•>. c> . .!.Fa... s� �: .., .::1':S . ..di APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities. --- le""' 1. Application Checklist (I copy) indicating items submitted with application. 2. Completed Application Form and drawings (5 copies). 17 3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site map, architectural elevations, method of attachment, proposed screening, location of proposed antennas, and all other information which accurately depicts the proposed project. Minimum size is 8 1/2" x 11". Plans shall be no greater than 24" x 36". ✓ 4. Application Fee: See Land Use Fee Schedule. c/ 5. Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property (1 copy attached). ✓ / 6. SEPA Environmental Checklist. SEPA is not required when the facility: i) Is a microcell and is to be attached to an exiting structure that is not a residence or school and does not contain a residence or a school; ii Includes personal wireless antennas, other than a microcell, and is to be attached to an existing structure (that may be an existing tower) that is not a residence or school and does not contain a residence or school, and the existing structure to which it is to be attached is located in a commercial, industrial, manufacturing, forest or agriculture zone; or iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a commercial, industrial, manufacturing, forest, or agricultural zone. �// 7. A letter from the applicant describing the proposed project and describing compliance with the City's Code requirements. 8. Sensitive Area studies and proposed mitigation (if required). 9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating compliance with TMC Chapter 8.22, "Noise". If the application requires a Type 2 review these additional items are needed: 10. Four sets of photo simulations that depict the existing and proposed view of the proposed facility; 11. Materials board for the screening material; 12. Landscaping plan; 13. Letter from a radio frequency engineer that demonstrates that the facility meets Federal requirements for allowed emissions; 14. If the facility is located within a residential zone, a report from a radio frequency engineer explaining the need for the proposed wireless communication facility at that location. Additionally, the applicant shall provide detailed discussion on why the wireless communication facility cannot be located within a commercial or industrial zone. HA -and Use Applications in PDF \W reless Communication Facility-Jan2Ol I.doc CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX: (206) 431-3665 E-mail: planning@a,TukwilaWA.gov WIRELESS TELE- COMMUNICATION FACILITIES INFORMATION City of Tukwila governs the placement of wireless telecommunication facilities under Tukwila Municipal Code (TMC) 18.58. The review process for new antennas and facilities is based on the type of facility and the location of the facility. The City's goal is to streamline the placement of desirable facilities that are located on existing cell towers, within commercial and industrial zones, and on electrical transmission towers. TABLE A Type of Permit Required, Based on Type of Wireless Communication Facility Zoning') Type of Facility Residential Commercial Industrial Transmission tower co -location Type 1 Type 1 Type 1 Adding antennas to an existing tower Type 1(2) Type 1(2) Typ 1(2) Utility pole co -location Type 2 Type 2 Type 2 Concealed building attached Type 2(3) Type 2(3) Type 1 Non -concealed building attached Type 2 Type 2 Type 1 New tower or waiver request Type 3 Type 3 Type 3 (1) (2) (3) Zoning for any private/public property or right-of-way: Residential — LDR, MDR, or HDR. Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS. Industrial — LI, HI, MIC/L, or MIC/H. Provided the height of the tower does not increase and the square footage of the enclosure area does not increase. An applicant may request to install a non -concealed building attached facility, under TMC Section 18.58.150. H:\Land Use Applications in PDF\Wireless Communication Facility-Jan20 1 1.doc RECEIVED CITY OF TUKWILA MAR 10 2014 �n,,,�„, WIRELESS TELE - Department of Community Developnl,jMI` 6300 Southcenter Boulevard, Tukwila, WA `COMMUNICATION Telephone: (206) 431-3670 FAX: (206) 431-3665 FACILITIES E-mail:: planning@TukwilaWA.gov APPLICATION FOR STAFF USE ONLY Permits Plus Type: P -WIRE Planner: File Number: 1.—`kA' l) Application Complete Date: Project File Number:1 LI 14,.0 [6 Application Incomplete Date: Other File Numbers: NAME OF PROJECT/DEVELOPMENT: "P'0-0,-17--2. 5 TOL- VO ILA- S g -O3 Xc..4Og LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). 000300 - 00o3 DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City, to whom all notices and reports will be sent. Name: RoNAtS) Address: tikitnotik iS4 TV- AV Nis- R-�DrvtmN� (N4 Phone: 4Zr^ 202.— 2?b3 FAX: cri3Os E-mail: 9.0,JrR,l i eXtt Q (:12-0w&JSTV . CO M Signature: H:\Land Use Applications in PDF\Wireless Communication Facility-Jan2011.doc Date: 3 - 6 - ZOIkt At all new services & grounding trenches, provide "WARNING" tape at 12" below grade. DIG ALERT "CALL BEFORE YOU DIG" 1-800-424-5555 UTILITY NOTIFICATION CENTER OF WASHINGTON RECEIVED MAR 10 2014 (tet )iJn n` L a 1 Y oEVELOt'M NT Spri ntc WASHINGTON STATE CODE COMPLIANCE: ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. • 2012 IBC, STANDARDS AND AMENDMENTS -WAC 51-50; • 2012 IMC, STANDARDS AND AMENDMENTS -WAC 51-52; • 2012 IFC, STANDARDS AND AMENDMENTS -WAC 51-54; • 2012 IPC, STANDARDS AND AMENDMENTS -WAC 51-56; 51-57 ACCESSIBILITY REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2009 IBC BUILDING CODE. CODE BLOCK ♦ SPRINT PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS FACIIJTY • INSTALL (3) NEW ANTENNAS (1 PER SECTOR) • INSTALL (3) RRH UNITS (1 PER SECTOR) • INSTALL 6 JUNCTION CYLINDERS (2 PER SECTOR) • INSTALL 3 FILTERS PROJECT DESCRIPTION APPROVAL SIGNATURE • DATE CCIA(?9Y1&" T-1 SITE ACQUISITION MANAGER PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY N-1 CONSTRUCTION MANAGER REVISIONS A-1 A&E MANAGER DESCRIPTION A-2 PLANNING CONSULTANT 01/30/14 A-3 RF MANAGER 0 A-4 RF ENGINEER AF A-5 PROPERTY OWNER A-6 SPRINT REPRESENTATIVE A-7 AAV MANAGER RF -1 SIGNATURE BLOCK THIS IS AN EXISTING SPRINT WIRELESS TELECOMMUNICATION FACILITY EQUIPMENT UPGRADE 2.5 LAUNCH TUKWILA SE03XC408 / CROWN 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY LATITUDE: 47.493744/ 47° 29' 37.4778" (NAD 83) (GOOGLE EARTH) LONGITUDE: -122.270610/ -122° 16' 14.196" (NAD 83) (GOOGLE EARTH) MONOPOLE • A AREA MAP VICINITY MAP DEPART FROM SPRINT OFFICE (BELLEVUE, WA): 1. HEAD SOUTH ON 124TH AVE NE TOWARD NE 10TH PL 2. TAKE THE 2ND RIGHT ONTO NE 8TH ST 3. SLIGHT RIGHT ONTO THE 1-405 S RAMP 4. KEEP LEFT AT THE FORK AND MERGE ONTO 1-405 S 5. TAKE EXIT 5 TOWARD WASHINGTON 900 E/PARK AVENUE NORTH 6. KEEP RIGHT AT THE FORK, FOLLOW SIGNS FOR PARK AVENUE N 7. CONTINUE ONTO LOGAN AVE N 8. SLIGHT RIGHT ONTO AIRPORT WAY 9. TURN LEFT ONTO RAINIER AVE S 10. TURN RIGHT ONTO SW SUNSET BLVD 11. CONTINUE ONTO MARTIN LUTHER KING WAY S 12. TURN LEFT ONTO S 129TH ST 13. CONTINUE ONTO 50TH PL S 14. TURN RIGHT TOWARD 5 124TH ST 15. TURN RIGHT ONTO S 124TH ST 16. TURN LEFT ONTO 51ST PL S DESTINATION WILL BE ON THE RIGHT 0.1 M 0.7 M 0.2 M 8.1 M 0.2 M 0.3 M 1.1 M 0.4 M 0.3 M 1.4 M 0.7 M 0.5 M 0.2 M 102 FT 203 FT 184 FT DRIVING DIRECTIONS • SEA 1 1 LE MARKET SHEET DESCRIPTION CCIA(?9Y1&" T-1 TITLE SHEET PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY N-1 GENERAL NOTES REVISIONS A-1 SITE PLAN & ENLARGED SITE PLAN DESCRIPTION A-2 COMPOUND PLAN 01/30/14 A-3 EQUIPMENT PLAN 0 A-4 ANTENNA PLANS & SCHEDULES AF A-5 EXISTING & PROPOSED SOUTHEAST ELEVATION A-6 "EXISTING & PROPOSED SOUTHWEST ELEVATION A-7 EQUIPMENT DETAILS RF -1 ANTENNA AND CABLE COLOR CODING DETAILS E-1 SCHEMATIC GROUNDING PLAN E-2 GROUNDING DETAILS E-3 GROUNDING DETAILS NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASHINGTON 2-18 1i_ REN. 02-18-15 4.0003 owl SHEET TITLE TITLE SHEET__ SHEETNUMBER:REVISION: T-1 0 SE03XC408 SHEET INDEX , I ♦ APPLICANT: SPRINT SPECTRUM LLC 1000 124TH AVE NE, SUITE 201 BELLEVUE, WA 98005 CONTACT: KEVIN FOY PH: (206) 427-5856 EMAIL: KEVIN.FOYOSPRINT.COM PROPERTY INFORMATION; PROPERTY OWNER: BNSF RAILWAY COMPANY ADDRESS: 2400 WESTERN CENTER BLVD FORT WORTH, TX 76131 TOWER OWNER: CROWN CASTLE USA SITE ID: 880338 ZONING CLASSIFICATION: C CONSTRUCTION TYPE: IIB OCCUPANCY: U JURISDICTION: CIN OF TUKWILA CURRENT USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY NEW USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY PARCEL NUMBER(S): 0003800003 LEASE AREA: 54'-O' ♦ PROJECT SUMMARY • ARCHITECT: THOMAS R. HOLLAND, AIA PACIFIC TELECOM SERVICES, LLC 506 2ND AVE, SUITE 210 SEATTLE, WA 98104 CONTACT: AMANDA MARTIN PH: (206) 342-6396 EMAIL AMARTINOPTSWA.COM STRUCTURAL ENGINEER: B+T GROUP 1717 S BOULDER, SUITE 300 TULSA, OK 74119 CONTACT: VENU AMBATI PH: (918) 587-4630 EMAIL: BIWOOBTGRP.COM PROJECT MANAGER: CROWN CASTLE USA 8432 154TH AVE NE, BLDG C REDMOND, WA 98052 CONTACT: TOM GOODE PH: (425) 202-0191 EMAIL TOM.GOODEOCROWNCASTLE.COM CONSTRUCTION MANAGER: CROWN CASTLE USA 8432 154TH AVE NE, BLDG C REDMOND, WA 98052 CONTACT: LEE BASSETT PH: (206) 852-0443 ZONING & PERMITTING: CROWN CASTLE USA 8432 154TH AVE NE, BLDG C REDMOND, WA 98052 CONTACT: KEVIN CHANG PH: (425) 202-2763 EMAIL: KEVIN.CHANGOCROWNCASTLE.COM ELECTRICAL COMPANY: PUGET SOUND ENERGY CONTACT: TIM GASSER PH: 206-947-0335 TELCO COMPANY: CENTURYUNK 8502 SOUTH STEELE ST TACOMA, WA 98409 RF ENGINEER: TBD Clq -06/ r • PROJECT TEAM THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint> CCIA(?9Y1&" -rte �AtIf IC TE L[COY SE9VIC E3. LLC 506 2N0 AYE, SUITE 210 SEATTLE. WA 96104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY ISSUE DATE 02-26-14 ISSUED FOR:CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INITIALS A 01/30/14 ISSUED FOR 908 CONSTRUCTION AF 0 02/26/14 ISSUED FOR 1008 CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASHINGTON 2-18 1i_ REN. 02-18-15 4.0003 owl SHEET TITLE TITLE SHEET__ SHEETNUMBER:REVISION: T-1 0 SE03XC408 GENERAL NOTES: 1. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND NETWORK CARRIER OF ANY ERRORS, OMISSIONS, OR INCONSISTENCIES AS THEY MAY BE DISCOVERED IN PLANS, DOCUMENTS, NOTES, OR SPECIFICATIONS, PRIOR TO STARTING CONSTRUCTION INCLUDING, BUT NOT LIMITED BY, DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERROR, OMISSION, OR INCONSISTENCY AFTER THE START OF CONSTRUCTION WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF ARCHITECT AND NETWORK CARRIER CONSTRUCTION PROJECT MANAGER AND SHALL INCUR ANY EXPENSES TO RECTIFY THE SITUATION. THE MEANS OF CORRECTING ANY ERROR SHALL FIRST BE APPROVED BY ARCHITECT AND NETWORK CARRIER CONSTRUCTION PROJECT MANAGER. 2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND THE CONTRACTOR HAVING BEEN AWARDED THIS PROJECT SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 3. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE NETWORK CARRIER PROJECT SCOPE AND THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 4. 11517 COPIES OF DRAWINGS ARE NOT TO BE SCALED DUE TO DISTORTIONS RESULTING FROM MULTIPLE REPROGRAPHIC COPIES. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALES SHOWN ON PLANS. 5. OWNER, CONTRACTOR, AND NETWORK CARRIER REPRESENTATIVE SHALL REVIEW AND CONFIRM THAT PROJECT SCOPE, DESIGN INTENT AND UTILITY COORDINATION ITEMS ARE INCLUDED IN THE DRAWINGS AND SPECIFICATIONS PRIOR TO THE START OF CONSTRUCTION. 6. THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION FROM NETWORK CARRIER REPRESENTATIVE TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 7. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS OR TENANTS. 8. THE CONTRACTOR SHALL PROVIDE NETWORK CARRIER PROPER INSURANCE CERTIFICATES NAMING NETWORK CARRIER AS ADDITIONAL INSURED, AND PROVIDE NETWORK CARRIER PROOF OF LICENSE(S) INCLUDING PE & PD INSURANCE. 9. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 10. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 11. ALL WORK PERFORMED ON THE PROJECT ALONG WITH ALL MATERIALS INSTALLED, SHALL COMPLY IN STRICT ACCORDANCE WITH ALL APPUCABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL LIKEWISE ISSUE NOTICE TO ALL SUB -CONTRACTORS THAT THEY SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAUTY, UTIUTY COMPANY AND LOCAL/STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 12. A COPY OF THE GOVERNING AGENCY ISSUED AND APPROVED PLANS SHALL BE KEPT IN A PLACE SPECIFIED BY THE GOVERNING AGENCY, AND BY LAW, SHALL BE AVAILABLE AT THE JOB SITE FOR INSPECTION AT ALL TIMES. THE ORIGINAL PERMIT SET PIANS ARE NOT TO BE USED BY THE WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS GOVERNING AGENCY APPROVED PLANS. THE CONTRACTOR SHALL ALSO MAINTAIN ONE SET OF PLANS, IN GOOD CONDITION, COMPLETE WITH ALL REVISIONS, ADDENDA. AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES UNDER THE DIRECT CARE OF THE SUPERINTENDENT. THE CONTRACTOR SHALL SUPPLY THE NETWORK CARRIER CONSTRUCTION PROJECT MANAGER WITH A COPY OF ALL REVISIONS, ADDENDA, AND/OR CHANGE ORDERS AT THE CONCLUSION OF THE WORK AS A PART OF THE AS -BUILT DRAWING RECORDS. 13. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACIUTIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 14. THE CONTRACTOR SHALL STUDY THE STRUCTURAL, ELECTRICAL, MECHANICAL, AND PLUMBING PLANS AND CROSS CHECK THEIR DETAILS, NOTES, DIMENSIONS. AND ALL REQUIREMENTS PRIOR TO THE START OF ANY WORK. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE JOB SITE WHILE WORK IS IN PROGRESS UNTIL THE JOB IS COMPLETE. 16. THE CONTRACTOR HAS THE RESPONSIBILITY OF LOCATING ALL EXISTING UTILITIES SHOWN OR NOT SHOWN ON THE PLANS, ALONG WITH PROTECTING THEM FROM DAMAGE. THE CONTRACTOR AND SUBCONTRACTOR SHALL BEAR THE EXPENSES OF REPAIR AND/OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGE RESULTING FROM OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK. 17. ALL EXISTING CONSTRUCTION, EQUIPMENT, AND FINISHES NOTED TO BE REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND WILL BE REMOVED FROM THE SITE WITH THE FOLLOWING EXCEPTIONS: A. PROPERTY NOTED TO BE RETURNED TO THE OWNER. B. PROPERTY NOTED TO BE REMOVED BY THE OWNER. 18. THE GOVERNING AGENCIES, CODE AUTHORITIES, AND BUILDING INSPECTORS SHALL PROVIDE MINIMUM STANDARDS FOR CONSTRUCTION TECHNIQUES. MATERIALS, AND FINISHES USED THROUGHOUT THE PROJECT. TRADE STANDARDS AND/OR PUBLISHED MANUFACTURERS SPECIFICATIONS MEETING OR EXCEEDING DESIGN REQUIREMENTS SHALL BE USED FOR INSTALLATION. 19. WHEN ROOF TOP OR TOP FLOOR DECK TEMPORARY STAGING IS REQUIRED, MATERIALS SHALL BE EVENLY DISTRIBUTED OVER ROUGH FRAMED FLOORS OR ROOFS SO AS NOT TO EXCEED THE DESIGNED LIVE LOADS FOR THE STRUCTURE. TEMPORARY SHORING AND/OR BRACING IS TO BE PROVIDED WHERE THE STRUCTURE DOESN'T HAVE THE DESIGN STRENGTH FOR ADDITIONAL LOADING. 20. SEAL ALL PENETRATIONS WITHIN FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THE SUBJECT FACILITY AND OR PROJECT SITE. 21. BUILDING INSPECTORS AND/OR OTHER BUILDING OFFICIALS ARE TO BE NOTIFIED PRIOR TO ANY GROUND DISTURBANCE, CONSTRUCTION, AND ANY OTHER PROJECT EFFORT AS MANDATED BY THE GOVERNING AGENCY. 22. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2 -Al OBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 23. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ADJACENT TO THE PROPERTY. 24. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION DISPOSING OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. 25. NEW CONSTRUCTION INSTALLED ADJACENT EXISTING BUILDINGS OR CONSTRUCTION SHALL ARCHITECTURALLY MATCH THE EXISTING IN TERMS OF COLOR, TEXTURE, FINISH MATERIALS, ETC., EXCEPT AS NOTED IN THE PLANS AND SPECIFICATIONS. 26. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BACKING, BLOCKING. AND/OR OTHER ANCHORAGE DEVICES REQUIRED FOR THE INSTALLATION OF FIXTURES, MECHANICAL EQUIPMENT, PLUMBING, HARDWARE, AND FINISH ITEMS TO INSURE A PROPER AND CODE COMPLIANT INSTALLATION. 27. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING INSTALLATIONS THAT ARE CONSTRUCTED LEVEL, ERECT, EVENLY ALIGNED, PLUMB AND TRUE BASED ON THE CONSTRUCTION DRAWINGS. THE CONTRACTOR SHALL COMPARE EXISTING CONDITIONS WITH THE PROPOSED DESIGN PRIOR TO CONSTRUCTION AND REPORT ANY DISCREPANCIES OR INCONSISTENCIES TO THE NETWORK CARRIER'S REPRESENTATIVE AND FURTHER TO THE A&E SUCH THAT THE NEW INSTALLATION WILL LIKEWISE BE LEVEL, ERECT, EVENLY ALIGNED, PLUMB AND TRUE. ARCHITECT AND NETWORK CARRIER SHALL BE NOTIFIED OF ANY ERRORS, OMISSIONS, OR INCONSISTENCIES PRIOR TO ANY CONSTRUCTION. 28. THE CONTRACTOR IS TO PROVIDE PROTECTION FOR ADJOINING PROPERTIES FROM PHYSICAL HARM, NOISE, DUST, DIRT, AND FIRE AS REQUIRED BY THE GOVERNING AGENCIES. 29. WHERE SPECIFIED, MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS AND/OR REVISIONS AVAILABLE AS REQUIRED BY THE GOVERNING AGENCY RESPONSIBLE FOR RECORDING THE RESULTS. 30. THE CONTRACTOR IS RESPONSIBLE FOR THE STORAGE OF ALL MATERIALS AND SHALL NOT STORE OR STAGE MATERIALS ON PUBLIC PROPERTY WITHOUT A PERMIT TO DO SO FROM THE GOVERNING AGENCIES FOR THIS PURPOSE. 31. GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS TO BE USED IN ALL CONDITIONS UNLESS ILLUSTRATED AND NOTED OTHERWISE. 32. TRADES INVOLVED IN THE PROJECT SHALL BE RESPONSIBLE FOR THEIR OWN CUTTING, FITTING, PATCHING, ETC., SO AS TO BE PREPARED PROPERLY BY THE WORK OF OTHER TRADES. 33. ALL DEBRIS AND REFUSE SHALL BE REMOVED FROM THE PROJECT PREMISES AND LEFT IN A CLEAN SWEPT CONDITION AT ALL TIMES BY EACH TRADE AS THEY PERFORM THEIR OWN PORTION OF THE WORK. 34. NETWORK CARRIER DOES NOT GUARANTEE ANY PRODUCTS, FIXTURES, AND/OR ANY EQUIPMENT NAMED BY A TRADE OR MANUFACTURER. GUARANTEE OR WARRANTY THAT MAY BE IN EFFECT IS DONE THROUGH THE COMPANY OR MANUFACTURER PROVIDING THE PRODUCT, FIXTURE. AND/OR EQUIPMENT UNLESS SPECIFIC RESPONSIBIUTY IS ALSO PROVIDED BY THE CONTRACTOR/SUBCONTRACTOR IN WRITTEN FORM. 35. CAUTION! CALL BEFORE YOU DIG! BURIED UTIUTIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. 36. WHEN APPUCABLE, CONTRACTOR IS RESPONSIBLE TO CALL, COORDINATE AND MAKE ARRANGEMENTS FOR R.O.W. AND/OR PRIVATE PROPERTY LOCATES BASED ON SPECIFIC SITE REQUIREMENTS. 37. SEE CIVIL DRAWINGS FOR ADDITIONAL SITE INFORMATION AS APPLICABLE. 38. CONTRACTORS TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO NETWORK CARRIER'S REPRESENTATIVE ALONG WITH REDUNED CONSTRUCTION SET. 39. CONTRACTOR SHALL DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP (REDLINING) THE APPROVED CONSTRUCTION SET AND SUBMITTING THE REDUNED ALONG WITH PHOTOGRAPHS PER NETWORK CARRIER REQUIREMENTS. 40. CONTRACTOR SHALL COORDINATE AND SEEK APPROVAL OF ALL POWER DRAW, INSTALLATION AND/OR MODIFICATIONS WITH POWER COMPANY, OWNER AND JURISDICTION AS REQUIRED. CONTRACTOR SHALL REPORT POWER INSTALLATION SOLUTION(S) TO NETWORK CARRIER REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHITECT. 41. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED BY NETWORK CARRIER CONSTRUCTION MANAGER. 42. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY ALL FAULTY, INFERIOR, AND/OR IMPROPER MATERIALS, DAMAGED GOODS, AND/OR FAULTY WORKMANSHIP FOR ONE (1) YEAR AFTER THE PROJECT IS COMPLETE ACCEPTING UNDER THIS CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. EXCEPTION: THE ROOFING SUBCONTRACTOR SHALL FURNISH A MAINTENANCE AGREEMENT FOR ALL WORK DONE, COSIGNED BY THE CONTRACTOR, TO MAINTAIN THE ROOFING IN A WATERTIGHT CONDITION FOR A PERIOD OF TWO (2) YEARS STARTING AFTER THE DATE OF SUBSTANTIAL COMPLETION OF THE PROJECT, UNLESS OTHERWISE WRITTEN IN THE CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. 43. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR THE SAFETY OF THE OWNER'S EMPLOYEES, WORKMEN, AND ALL TIMES DURING THE CONSTRUCTION OF THE PROJECT. 44. THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ALL NECESSARY PERMITS AND/OR FEES WITH RESPECT TO THE WORK TO COMPLETE THE PROJECT. BUILDING PERMIT APPLICATIONS SHALL BE FILED BY THE OWNER OR HIS REPRESENTATIVE. CONTRACTOR SHALL OBTAIN PERMIT (UNLESS OTHER ARRANGEMENTS HAVE BEEN MADE) AND MAKE FINAL PAYMENT FOR SAID DOCUMENT(S). 45. NETWORK CARRIER'S REPRESENTATIVE SHALL REVIEW AND APPROVE SHOP DRAWINGS AND SAMPLES FOR CONFORMANCE WITH DESIGN CONCEPT. NETWORK CARRIER'S REPRESENTATIVE PROJECT APPROVAL OF A SEPARATE ITEM SHALL NOT INCLUDE APPROVAL OF AN ASSEMBLY IN WHICH THE ITEM FUNCTIONS. 46. ALL ANTENNAS MOUNTED ON ROOF SUPPORT FRAMES TO BE PROVIDED BY NETWORK CARRIER. 47. CONTRACTOR SHALL PROVIDE HEAVY STEEL PLATES AT OPEN TRENCHES FOR SAFETY AND TO PROTECT EXISTING GROUND SURFACES FROM HEAVY EQUIPMENT UTILIZED DURING CONSTRUCTION. 48. CONTRACTOR SHALL PATCH AND REPAIR ALL GROUND SURFACES WITHIN THE CONSTRUCTION AREA AS NECESSARY TO PROVIDE A UNIFORM SURFACE AND MAINTAIN EXISTING SURFACE DRAINAGE SLOPES. 49. CONTRACTOR SHALL REPLACE EXISTING LANDSCAPE VEGETATION DAMAGED DUE TO CONSTRUCTION ACTIVITIES, AND REPAIR, RESTORE AND MODIFY EXISTING IRRIGATION LINES IF NECESSARY TO OPERATING CONDITION, PROVIDING FULL COVERAGE TO IMPACTED AREAS. 50. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER TO OBTAIN CONTACT INFORMATION AND UTIUZE THE EXISTING ROOFING CONTRACTOR OF RECORD FOR INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION TO THE ROOF, AND HAVING THE WORK GUARANTEED UNDER THE ROOFING CONTRACTOR'S EXISTING WARRANTY ENSURING 100% MOISTURE PROTECTION. 51. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS WITHIN CONCEALED (SHROUDED) SUPPORT FRAMES OR TRIPODS, CONTRACTOR SHALL COORDINATE WITH THE FRP DESIGNER/FABRICATOR TO ENSURE THAT THE FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) EXISTING EXTERIOR BUILDING FACADE MATERIALS, TEXTURES, AND COLORS. THE CONTRACTOR SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK OR FLATHEAD AN FASTENERS IN ALL FRP CONSTRUCTION. WHEN PHOTOSIMULATIONS ARE PROVIDED, THE CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT IS INDICATED IN PHOTOSIMULATION. SHOP DRAWINGS SHALL BE PROVIDED TO THE CONTRACTOR, CONSTRUCTION COORDINATOR, AND ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION. ANTENNA & COAX NOTES VERIFY EACH COAXIAL CABLE LENGTH, DIAMETER, ROUTING, COLOR CODING AND ALL APPURTENANCES WITH NETWORK CARRIER REPRESENTATIVE. 2. THE MAXIMUM COAXIAL CABLE LENGTH AND CORRESPONDING COAXIAL CABLE DLAMETER HAS BEEN ESTIMATED. THIS CABLE LENGTH IS APPROXIMATE, AND IS NOT TO BE USED FOR FABRICATION OR CONSTRUCTION. ACTUAL ANTENNA CABLE LENGTH(S) MAY VARY FROM ESTIMATED MAXIMUM LENGTH AND MUST BE VERIFIED. COAXIAL CABLE SHALL BE PROVIDED BY NETWORK CARRIER REPRESENTATIVE. 3. ALL MAIN CABLES SHALL UTILIZE GROUND KITS, GROUNDED AS FOLLOWS: A. NEAR ANTENNA RAD CENTER ELEVATION, B. MIDDLE OF TOWER (MID -HEIGHT OF ANTENNA), IF CABLE RUN IS OVER 200', C. BOTTOM OF TOWER, D. AT MASTER GROUND BAR 3'-0" FROM MMBS-BBU CABINET. 4. ALL TOP JUMPERS SHALL BE LENGTHS AS SHOWN AND INSTALLED BY CONTRACTOR. 5. ALL MAIN CABLES SHALL BE COLOR CODED PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN ON RF SHEET(S) AND IN ACCORDANCE WITH NETWORK CARRIER SPECIFICATIONS. 6. BANDING SHALL BE IN ACCORDANCE PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN RF SHEET(S) AND AS FOLLOWS: A. MAIN UNE COLOR BANDS SHALL BE 2" WIDE. MAINTAIN 1" SPACING BETWEEN COLORS. B. FREQUENCY COLOR BANDS SHALL BE 2" WIDE WITH NO SPACE BETWEEN COLORS. C. JUMPER COLOR BANDS SHALL BE 1" WIDE. WITH 1" SPACE. D. START COLOR BANDS 2" BEYOND WEATHERPROOFING. E. START SELECTOR COLOR NEXT TO END CONNECTORS. 7. FINAL COAXIAL ANTENNA CABLE SIZES SHALL BE DETERMINED ENGINEER. SEE ANTENNA SCHEDULE. BY NETWORK CARRIER RF 8. SEE CONSTRUCTION MANAGER FOR ANTENNA SUPPORT ASSEMBLY TYPE. ON 9. ALL COAXIAL CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE AT DISTANCES NOT TO EXCEED 3' OR THE CABLE MANUFACTURES SPECIFICATIONS WHICHEVER IS LESS, WITH HARDWARE SPECIFIED IN THE COAXIAL CABLE ROUTING DETAILS OF THE SUPPLIED STRUCTURAL REPORT. 10. PROVIDE AT LEAST 6" OF SLACK IN THE MAIN COAXIAL CABLES AT THE ANTENNA MOUNTING ELEVATION TO PROVIDE FOR FUTURE CONNECTOR REPLACEMENT. 52. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE ANCHORING TO AN EXISTING CONCRETE ROOF SLAB IS REQUIRED, CONTRACTORS SHALL CONFIRM (PRIOR TO SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF POST TENSION TENDONS WITHIN THE ROOF SLAB RESULTING FROM AN UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING "AS -BUILT DRAWING SET" HAVING INDICATED AN ORIGINAL DESIGN SOLUTION OF REINFORCED CONCRETE W/ EMBEDDED STEEL REBAR. IN THE EVENT POST TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE PROVISIONS FOR X-RAY PROCEDURES (INCLUDED IN BID) FOR ALL PENETRATION AREAS WHERE ANCHORING OCCURS. 53. GENERAL & SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL CABUNG TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS (WHERE APPLICABLE). PLASTIC ZIP TIES SHALL NOT BE PERMITTED FOR USE ON TOWER NETWORK CARRIER PROJECTS. RECOMMENDED MANUFACTURE SHALL BE PANDUIT CORP. METAL LOCKING TIES MODEL NO. MLT4S-CP UNDER SERIES -304 (OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC. 54. CONTRACTOR SHALL OBTAIN, REVIEW AND EXECUTE ALL NETWORK CARRIER CONSTRUCTION STANDARDS (MOST RECENT REVISION) AS A PART OF THIS BID AND CONSTRUCTION PROJECT. 55. CONTRACTOR SHALL OBTAIN, REVIEW AND EXECUTE ALL NETWORK CARRIER CONSTRUCTION STANDARDS (MOST RECENT REVISION) AS A PART OF THIS BID AND CONSTRUCTION PROJECT. 56. CONTRACTOR SHALL BE RESPONSIBLE TO SET ELECTRONIC TILTS FOR NEWLY INSTALLED ANTENNAS UNDER THE CONDITION THAT THE CONTRACTOR OBTAIN THE MOST RECENT COPY OF THE RF TILT INFORMATION SUCH THAT THE ACCURATE CONTROLLER CAN BE ORDERED AND INSTALLED. 57. A STRUCTURAL ANALYSIS SHALL BE COMPLETED AND SUBMITTED TO THE NETWORK CARRIER REPRESENTATIVE AND CONTRACTOR DEMONSTRATING CAPACITY AT THE EXACT LOCATION OF EXISTING CONDITIONS TO SUSTAIN ADDITIONAL HEAVY BATTERY CABINETS OR OTHER OUT OF SCOPE EQUIPMENT. 58. THE CONTRACTOR SHALL PROVIDE MATERIALS UST (BOM) TO THE NETWORK CARRIER REPRESENTATIVE PRIOR TO CONSTRUCTION. TENNA & HYBRID COAX NOTES VERIFY EACH HYBRID CABLE LENGTH, DIAMETER, ROUTING, COLOR CODING AND ALL APPURTENANCES WITH NETWORK CARRIER REPRESENTATIVE. 2. THE HYBRID CABLE LENGTH AND CORRESPONDING DIAMETER HAS BEEN ESTIMATED. THIS CABLE LENGTH IS APPROXIMATE, AND IS NOT TO BE USED FOR FABRICATION OR CONSTRUCTION. ACTUAL ANTENNA CABLE LENGTH(S) MAY VARY FROM ESTIMATED MAXIMUM LENGTH AND MUST BE VERIFIED. EXCESS CABLE LENGTHS TO BE DRESSED IN A MANNER APPROVED BY NETWORK CARRIER REPRESENTATIVE. CABLES CANNOT BE CUT TO FIT. 3. HYBRID CABLE INTERNAL GROUND WIRE TO BE GROUNDED AT TOP AND BOTTOM PER NETWORK CARRIER SPECIFICATIONS. 4. EXCESS TOP 15' HYBRID CABLE FIBER JUMPERS TO BE DRESSED IN A MANNER APPROVED BY NETWORK CARRIER REPRESENTATIVE, CANNOT BE COILED, MUST BE SECURED TO TOWER MOUNTS. 5. ALL MAIN CABLES SHALL BE COLOR CODED PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN ON RF SHEET(S) AND IN ACCORDANCE WITH NETWORK CARRIER SPECIFICATIONS. 6. BANDING SHALL BE IN ACCORDANCE PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN ON RF SHEET(S) AND AS FOLLOWS: A. MAIN UNE COLOR BANDS SHALL BE 2" WIDE. MAINTAIN 1" SPACING BETWEEN COLORS. B. JUMPER COLOR BANDS SHALL BE 1" WIDE. WITH 1" SPACE. C. START COLOR BANDS 2" BEYOND WEATHERPROOFING. 7. FINAL HYBRID CABLE SIZES SHALL BE DETERMINED BY NETWORK CARRIER RF ENGINEER. SEE CABLE SCHEDULE, BASED UPON FINAL RUN LENGTHS DETERMINED BY NETWORK CARRIER REPRESENTATIVE. 8. ALL HYBRID CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE AT DISTANCES NOT TO EXCEED 3' HORIZONTALLY OR 4' VERTICALLY OR THE CABLE MANUFACTURES SPECIFICATIONS WHICHEVER IS LESS, WITH HARDWARE SPECIFIED IN THE COAXIAL CABLE ROUTING DETAILS OF THE SUPPLIED STRUCTURAL REPORT. Liti-ao/r THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. S r i n t> P CC6A NST � 0 -rte P4CIf It TE LEC OY SE9YIC E5. LLC 506 2N0 AVE. SUITE 210 SEATTLE. WA 96104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY ISSUE DATE 02-26-14 ISSUED FOR:CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INITIALS A 01/30/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T / THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-18 1= 0404 00100 SHEET TITLE GENERAL NOTES SHEET NUMBER: N-1 REVISION: 0 SE03XC408 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY 8Y NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint> ?ii(?517V. F -0 '1 / 1"..... S 129tH sr ARO 'Op ry N oG�gMisy R/�f� F R TRUE MAGNETIC NORTH NORTH • PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA. WA 98178 KING COUNTY / // _ I i i IP f BUILDING NG ILII' gIIII \ ISSUED FOR CONSTRUCTION DWGS REVISIONS A SITE ,11111111, DATE DESCRIPTION INITIALS PARCEL NO.: 0003800003 STRIP THRU 0 C IN SW 1/4 & OVER POR GL 4 IN SD SW 1/4 FT BN RR R/W GENERAL NOTES LEGAL DESCRIPTION: THESE DRAWINGS WERE PRODUCED WfTHOUT THE BENEFIT OF A CURRENT LAND SURVEY. ALL PROPERTY LINES, EASEMENTS, SETBACKS AND EXISTING CONDITIONS ARE APPROXIMATE AND SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION. JOHNS 8 -L -D -C #47 400FT 11-23-04 & SE 10-23-04 11-23-04 LY WLY OF 100 // //// PROPERTY LINE r 11, I EXISTING SPRINT EO �Ao� IP -- / // 11111 TING OKIINNG ...."-- .../S\ / \ BEXISTING UILDING IIID, TRUE MAGNETIC NORTH NORTH ..., - ..p., - 0 IIIIIiIi. 1/////, '/��j//// i PROPERTY LINE' I r� � 6Y = U I � � EXISTING q\ V/^ zaN 1 PARRKANG c I \ I EXISTING `Q� I \ TREE >S, I XISTING 7 �P SITE , P�r" G* -=,.5 EXISTING SPRINT S BUILDING S\ EXISTING BUILDING SpA AP ��.`� .fr 4+i,, ‹.-_, EXISTING PARKING \ / l'1- A'A .ffT I- 4" \ ` } IXISTING IIIIIb BUILDING. 01%t 4.I, O Pp.' �QO // G \ EXISTING TREE i /' / iti APN: 0003800003 ZONING: C // EXISTING PARKING AREA APN: 0003800003 ZONING: C loll 001 e5" EXISTING BUILDING \ • "\ L// 7{1EEG • \ / L 24"x36" SCALE: 11"x17" SCALE: 1" = 1" = 150'-0"24"x36" SITE PLAN 1 SCALE: 1" = 30'-0" 11•x17" SCALE 1" = 60'-0" 3D ENLARGED SITE PLAN 2 300'-0" 150' 70" 160' 1� o D. THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY 8Y NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint> ?ii(?517V. —r rAcTELECOM r , va SERVICES. 506 260 AVE. SUITE 210 SEATTLE. WA 98104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA. WA 98178 KING COUNTY ISSUE DATE 02-26-14 ISSUED FOR CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INITIALS A 01/30/14 ISSUED FOR 905 CONSTRUCTION AF 0 02/26/14 ISSUED FOR 1005 CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-18-1= 1 SHEET TFILE SITE PLAN & ENLARGED SITE PLAN SHEET NUMBERREVISION: A-1 0 SE03XC408 EXISTING PCS (2'-6"X8'-6") LP TANK/AREA EXISTING SPRINT EQUIPMENT CABINET EXISTING SPRINT CABLE ROUTE EXISTING SPRINT CABLE TRAY EXISTING CHAIN LINK FENCE EXISTING SPRINT 2'-0"X2'-0" CABINET EXISTING TELCO BOX EXISTING SPRINT ANTENNA LOCATION AT EXISTING MONOPOLE - PROPOSED MODIFICATION LOCATION 111111111111!;II1, I�iillill I;Illlj!' EXISTING SPRINT GPS ANTENNA EXISTING SPRINT PPC CABINET MOUNTED ON 4"X4" TUBE STEEL POST EXISTING 80'-0" AGL MONOPOLE EXISTING UAM/CIENA BOX MOUNTED ON H -FRAM E EXISTING CONCRETE SLAB EXISTING RETAINING WALL EXISTING GENERATOR EXISTING 4'-0" ACCESS GATE EXISTING SPRINT TELCO CABINET MOUNTED ON 4"X4" TUBE STEEL POST EXISTING METER EXISTING SPRINT EQUIPMENT/LEASE AREA AT CONCRETE SLAB ON GROUND - NO PROPOSED MODIFICATION TRUE MAGNETIC NORTH NORTH 24"x36" SCALE 1/2" = 1'-0" 11"x17" SCALE 1/4" = 1'-0" 2' 1' 0" 2' COMPOUND PLAN 1 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint) 0 CC8A(?5ffi? —i— PACIFIC TELECOM5 . LLC 506.2N0 AVATTLE,EW. A961SUITE04 210 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY ISSUE DATE 02-26-14 ISSUED FOR:CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INIRALS A 01/30/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-18-15 6_ SHEET TITLE COMPOUND PLAN SHEET NUMBER:REVISION: A-2 0 SE03XC408 EXISTING PCS * \ (2'-6"X8'-6") EXISTING ICE BRIDGE 0 CC8/41?5W? LP TANK/AREA +� 7 f • \ EXISTING SPRINT EXISTING SPRINT i. f BOX � CABLE ROUTE O ��� \ MOUNTED / \ MOUNTED ON H -FRAME EXISTING SPRINT i J CT / \ f EQUIPMENT CABINET NV° } EXISTING SPRINT G� / /%ISTING ��11. EXISTING SPRINT 2'-0"X2'-0" CABINET CONCRETE 'I� PCS 2'-0"X4'-0" EXISTING SPRINT SLAB? CABLE TRAY•11� EXISTING SPRINT � ICE BRIDGE �' � �4/ EXISTING ��'�/ r• \ TELCO BOX i`� 1 EXISTING 4'-O" As. \ /�\ '.� ' _'� ACCESS GATE Ill/ } EXISTING SPRINT \ METER BOARD 3'-0" + i� WORKING CLEARANCE 1110 /� IIIA NOTE. NO PROPOSED WORK TO EXISTING A III I AF �%/ ���• SPRINT GROUND EQUIPMENT ISSUED FOR 100% CONSTRUCTION 0 �. O �I1 A • QOG 9\�• + 1� III' `` `!% 10\ °'!I EXISTING SPRINT , %� GPS ANTENNA oyP 9 ,,..,:ns IP,• /% EXISTING SPRINT 1 \ �� •IN BBU CABINET J,'• MMES CABINET NORTH NORTH //� EXISTING SPRINT TRUE MAGNETIC 1/ EXISTING CHAIN EXISTING SPRINT o' LINK FENCE ��` TELCO CABINET �� EXISTING METER MOUNTED ON 4"X4" I ' _ TUBE STEEL POST EXISTING SPRINT PPC CABINET /�i EXISTING RETAINING WALL MOUNTED ON 4"X4" TUBE STEEL POST 24"x36" SCALE: 1/4" = 1'-0 EQUIPMENT PLAN 1 . NOT USED 2 11"x17" SCALE 1/8" = 1'-0" 4' 3' 2 1 0 4' L /4»/( NOT USED 3 NOT USED 4 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint> 0 CC8/41?5W? --1— PACIFIC TELECOM SERVICE!, LLC 506 2ND AVE SUITE 210 SEATTLE, WA 98104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY ISSUE DATE 02-26-14 ISSUED FOR: CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION PETALS A 01/30/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-18-1= .00.04 SHEET TITLE EQUIPMENT PLAN SHEET NUMBER:REVISION: A-3 0 SE03XC408 EXISTING SPRINT 1900MHz RRH MOUNTED BEHIND ANTENNA " (1 PER SECTOR, 3 TOTAL) I EXISTING SPRINT 1900MHz ANTENNA ��-,�, e II �i" (1 PER SECTOR, 3 TOTAL) I ei EXISTING EMPTY PIPE MOUNT (NP) .o'"•��III 1 ij l�`. G e I I4? '� ww e \ EXISTING 80'-0" ''II ;, III AGL MONOPOLE ,,III, e .IIIIIIIIU' e ° (P\ C-1. -7\0r�% NORM NORMO 7 \0 1-6..\1)\ ds 4-\-O 2\ 24"x36" SCALE: 1/2" = 1'-0" I 1 NOT USED 2 I EXISTING ANTENNA PLAN 11"x17" SCALE: 1/4" = 1'-O" 2' 1' 0 2' PROPOSED SPRINT IIIIIIIII FILTER MOUNTED BEHIND 'IIIIIII ANTENNA, BELOW RRH (1 PER SECTOR, 3 TOTAL) NOTE STRUCTURAL ANALYSIS MUST BE PREFORMED ON ALL ROOFTOPS, FLAGPOLES AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, NEW RRUS, & NEW CABINETS/TEMPORARY PLATFORM. NOTE EXISTING ANTENNAS ARE CDMA UNLESS NOTED OTHERWISE. NEW SPRINT ANTENNAS INCLUDE RESPECTIVE RRU'S WHICH SHALL BE MOUNTED ON THE PIPE BEHIND THE ANTENNA. FIELD VERIFY EXISTING AZIMUTH BEFORE RELOCATING THE ANTENNA, IF REQUIRED. PRIOR APPROVAL FROM SPRINT TO BE GRANTED BEFORE RELOCATION OF ANTENNAS. NOTES ALL AZIMUTHS ARE TO BE ESTABUSHED CLOCKWISE FROM THE TRUE NORTH HEADING. CONTRACTOR SHALL VERIFY NEW ANTENNA RAD CENTER AND ORIENTATIONS WITH SPRINT PCS PRIOR TO INSTALLATION OF ANTENNAS. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, EXISTING TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LICENSED STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING THE NEW LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS. CONTRACTOR SHALL REFER TO TOWER STRUCTURAL CALCULATIONS FOR ADDITIONAL LOADS. NO ERECTION OF MODIFICATION OF TOWER SHALL BE MADE WITHOUT APPROVAL OF STRUCTURAL ENGINEER. PROPOSED SPRINT 2.5GHz RRH MOUNTED 1!1 `k BEHIND ANTENNA IIID (1 PER SECTOR, 3 TOTAL) EXISTING SPRINT 1900MHz RRH MOUNTED BEHIND ANTENNA PROPOSED SPRINT 2.5GHz ANTENNA MOUNTED III!III ISSUED FOR 905 CONSTRUCTION (1 PER SECTOR, 3 TOTAL) N EXISTING MOUNT 'x:1111 (1 PER SECTOR, 3 TOTAL) EXISTING SPRINT 1900MHz ANTENNA e l ° III. IIII (1 PER SECTOR, 3 TOTAL) NG P \ai ISI nu-- P�\M / \%125 �;�� ..s0.'‘.1,\)\\ 4-i F'D �l2 EXISTING EMPTY PIPE MOUNT (TYP) „II ;'" �r1F' 11P: {! 4°,,....<�p''" P,1 G/OR\,���� �� S, PI `� ., 6� ` NP _.--. \.;1 AF RRU /HYBRID CABLE SCHEDULE SECTOR RRU MODEL RRU FREQUENCY HYBRID CABLE LENGTH HYBRID CABLE DIAMETER JUMPER SZ2" JUMPER LENGTH RET LENGTH RET CABLE MANUFACTURER RET CABLE MODELNUMB ALPHA RRH-V3 2.5 GHz 1\\ AMODBE 6 BETA RRH-V3 2.5 GHz 125' N/AN 1/2" 6' 9.8' COMMSCOPE ATCB-B01-006 LICENSURE 4072 REGISTERED '' ARC IT T THOMAS R. HOLLAND 1 STATE OF WASHINGTON REN. 02-18-15 0.00.3 osi GAMMA RRH-V3 2.5 GHz 125' N/A 1/2" 6' 9.8' COMMSCOPE ATCB-B01-006 ANTENNA SCHEDULE ° e EXISTING 80'-0" ;. SECTOR ANTENNA FREQUENCY ANTENNA MFR. ANTENNA MODEL ANTENNA QUANTITY AZIMUTH RAD CENTER ANT. SZE ELECT TILT MECH TILT ALPHA 2.5 GHz KMW ET-X-WM-18-65-81. 1 (PER SECTOR) 60' 77'-0" 61.0" 0' 0' BETA 2.5 GHz KMW ET-X-WM-18-65-81. 1 (PER SECTOR) 155' 77'-0" 61.0" 0' 0' AGL MONOPOLE II" -VIII IIIIIII:II' N j\ ;.:: :�• \\1i SiS �G ' ct5\-A �.., 3 1;\ --\"3 , , 1-\.. ° 16.5' �n \O TRUE YAONEnc NORTN NORTH .G�\tea �l\A I� ' \ 1 •t GAMMA 2.5 GHz KMW ET-X-WM-18-65-8P 1 (PER SECTOR) 240' 77'-0" 61.0" 0' 0' NOTE: STRUCTURAL ANALYSIS MUST BE ON ALL S FLAGPOLESPREFORMEAND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, NEW RRH UNITS, & NEW CABINETS/TEMPORARY PLATFORM. ANALYSIS TO BE PERFORMED BY REGISTERED STRUCTURAL ENGINEER. Llq.00,,r 24"x36" SCALE: 1/2" = 1' -0", 3 NOTES & ANTENNA SCHEDULE 4 11"x17" SCALE: 1/4" = 1'-0" 2' 1' 0" 2' ANTENNA PLAN IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint> 0 CC6A(?5"ifr? —rteTELECOM EEVICES, C 506 2ND AVE, SUITE 210 SEATTLE, WA 96104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY ISSUE DATE 02-26-14 ISSUED FOR:CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INITIALS A 01/30/14 ISSUED FOR 905 CONSTRUCTION AF 0 02/26/14 ISSUED FOR 1005 CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED '' ARC IT T THOMAS R. HOLLAND 1 STATE OF WASHINGTON REN. 02-18-15 0.00.3 osi SHEET TITLE: ANTENNA PLANS & SCHEDULES SHEET NUMBER:REVISION: A-4 0 SE03XC408 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint> 0 CC6A?9fff? NOTE' STRUCTURAL ANALYSIS MUST BE PREFORMED ON ALL ROOFTOPS, FLAGPOLES AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, NEW RRH UNITS, & NEW CABINETS/TEMPORARY PLATFORM. ANALYSIS TO BE PERFORMED BY REGISTERED STRUCTURAL ENGINEER. PACIFIC TELCCOY SERVICES. LLC 505 280 AVE, Swop SEATU.E, WA 80104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY \ LSSUEDFOR CONSTRUCTION DWGS REVISIONS \ DATE DESCRIPTION INIMLS A 01/30/14 ISSUED FOR 90% CONSTRUCTION PROPOSED SPRINT 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF 2.5GHzMOUNTED II III— TOP OF EXISTING MONOPOLE 79'-7' TOP OF PROPOSED SPRINT PANEL ANTENNAS 77'-0' • .... _i111 "1 ON EXISTING MOUNT (1 PER SECTOR, 3 TOTAL)IIIIII;II PROPOSED TOP OF EXISTING MONOPOLE 79'-T TOP OF EXISTING SPRINT PANEL ANTENNAS 77-0' 1 SPRINT 2.5GHz RRH MOUNTED III (III BEHIND ANTENNA ° III'I (1 PER SECTOR, 3 TOTAL)( 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-18-1= 0.00.3 SHEET TITLE EXISTING & PROPOSED SOUTHEAST ELEVATION SHEET NUMBER: A-5 PROPOSED SPRINT FILTER MOUNTED BEHIND ,1111111 ANTENNA, BELOW RRH lil (1 PER SECTOR, 3 TOTAL) 11 lel EXISTING SPRINT 1900MHz RRH MOUNTED BEHIND ANTENNA (1 PER SECTOR, 3 TOTAL) EXISTING SPRINT 1900MHz RRH MOUNTED BEHIND ANTENNA (1 PER SECTOR, 3 TOTAL) EXISTING SPRINT 1900MHz ANTENNA (1 PER SECTOR, 3 TOTAL) 41. _ COSTING SPRINT 1900MHz ANTENNA (1 PER SECTOR, 3 TOTAL) RAD CENTER OF EXISTING SPRINT PANEL ANTENNAS EXISTING OTHER CARRIER ANTENNAS ARRAY RAD CENTER OF EXISTING/PROPOSED SPRINT PANEL ANTENNAS EXISTING OTHER CARRIER ANTENNAS ARRAY EXISTING 80'-0" AGL MONOPOLE EXISTING 50•-0" AGL MONOPOLE 0 I EXISTING SPRINT CABLE ROUTE INSIDE MONOPOLE 0 1 m • EXISTING SPRINT CABLE ROUTE INSIDE MONOPOLE EXISTING SPRINT TELCO CABINET MOUNTED ON 4"X4" TUBE STEEL POST a (STING SPRINT IXISTING SPRINT TELCO CABINET MOUNTED ON 4"X4• TUBE STEEL POST EQUIPMENT CABINETS EXISTING SPRINT EQUIPMENT CABINETS DUSTING SPRINT GPS ANTENNA EXISTING SPRINT GPS ANTENNA EXISTING SPRINT UPPER ICE BRIDGE EXISTING EXISTING SPRINT UPPER ICE BRIDGE IXISTING UAM/CIENA BOX MOUNTED ON H -FRAME ., UAM/CIENA BOX MOUNTED ON H -FRAME EXISTING SPRINT EXISTING SPRINT I•,N„ }'e.• :0.. ,�- , ee •'S:•\, e e. :�:�:�{�:•::::':•..•. .0.e• i:L:Y:• .• • ..... �.iA^i \"} . : Ve• O•f:f• :•:•1 i•}}''::�:�J.�.}•;'i . � LOWER ICE BRIDGE i;:• e Y•1eY}'•i}i�1:�1::�:•:•::•::•:ti1:•:•:•''::':i:•:❖:❖ :•YJr:•''r ''r. i'::i;ii � j0.1:•J••:.•:':4❖:ti r :ii LOWER ICE BRIDGE GRADE ,,. e:• ::ti:• :}i::::•i:•:•:•: q.,; •dry ��;: ., e, :•. e.. EXISTING 6•-0" HIGH CHAIN LINK FENCE••'•"• GRADE :•:1.:• »0.. ...�.__- e,,,e. 0..,.,{e.4,.,:•::•::•:: eee•....:•ee•••ev::r• :• • ........... ...... .. EXISTING 6•-0" HIGH CHAIN UNK FENCE L. /4/ - Oar 24•x36• SCALE: 3/16• = 1•-0" .m.= EXISTING SOUTHEAST ELEVATION 1 24•x36• SCALE: 3/16" = 1•-0• ,• PROPOSED SOUTHEAST ELEVATION 2 ,rxn" scALE: 3/32" = r—Q• 4 11•x17• SCALE: 3/32" = 1 -0 4' 2 0 4' THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint> 0 CC6A?9fff? —i— PACIFIC TELCCOY SERVICES. LLC 505 280 AVE, Swop SEATU.E, WA 80104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY ISSUE DATE 02-26-14 LSSUEDFOR CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INIMLS A 01/30/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-18-1= 0.00.3 SHEET TITLE EXISTING & PROPOSED SOUTHEAST ELEVATION SHEET NUMBER: A-5 REVISION: 0 SE03XC408 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint). 0 C?AYN •-r- NOTF• STRUCTURAL ANALYSIS MUST BE PREFORMED ON ALL ROOFTOPS, FLAGPOLES AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, NEW RRH UNITS, & NEW CABINETS/TEMPORARY PLATFORM. ANALYSIS TO BE PERFORMED BY REGISTERED STRUCTURAL ENGINEER. PACIFIC TELECOM SERVICES, LLC 506.2ND AVE. ATTLE,WA 981SURE04 210 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 95175 KING COUNTY TOP OF EXISTING MONOPOLE 79'-7. ISSUED FOR CONSTRUCTION DWGS REVISIONS ,I, DATE DESCRIPTION PROPOSED SPRINT A TOP OF EXISTING MONOPOLE 79'-3" ISSUED FOR 90% CONSTRUCTION AF 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF 2.5GHz ANTENNA MOUNTED '.:: Nil _'I I EXISTING MOUNT ,111!;111 (1 PER SECTOR, 3 TOTAL) 11111;1 0 PROPOSED SPRINT 2.5GHz RRH MOUNTED 11111111 BEHIND ANTENNA Ilnr1 (1 PER SECTOR, 3 TOTAL) 'ILII II PROPOSED SPRINT FILTER MOUNTED BEHIND III' ANTENNA, BELOW RRH Ii IIIIII (1 PER SECTOR, 3 TOTAL) III — EXISTING SPRINT 1900MHz RRH MOUNTED BEHIND ANTENNA (1 PER SECTOR, 3 TOTAL) EXISTING SPRINT 1900MHz RRH MOUNTED BEHIND ANTENNA (1 PER SECTOR, 3 TOTAL) NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE EXISTING SPRINT 1900MHz ANTENNA 4- J SHEET NUMBER A-6 (1 PER SECTOR, 3 TOTAL) SE03XC408 ' I .. EXISTING SPRINT 1900MHz ANTENNA (1 PER SECTOR, 3 TOTAL) RAD CENTER OF EXISTING/PROPOSED SPRINT PANEL ANTENNAS EXISTING OTHER CARRIER ANTENNAS ARRAY RAD CENTER OF EXISTING SPRINT PANEL ANTENNAS EXISTING OTHER CARRIER ANTENNAS ARRAY EXISTING 50'-0" AGL MONOPOLE EXISTING BO' -0" AGL MONOPOLE 0 m EXISTING SPRINT CABLE ROUTE INSIDE MONOPOLE 0 m EXISTING SPRINT CABLE ROUTE INSIDE MONOPOLE EXISTING 6'-0" HIGH CHAIN LINK FENCE EXISTING 6'-0" HIGH CHAIN LINK FENCE EXISTING SPRINT GPS ANTENNA EXISTING SPRINT GPS ANTENNA EXISTING SPRINT ICE BRIDGE EXISTING SPRINT ICE BRIDGE EXISTING SPRINT EQUIPMENT CABINETS / EXISTING SPRINT EQUIPMENT CABINETS /CEG SPRINT TELCO CABINET MOUNTED ON 4"X4" TUBE STEEL POST 11 CAESPRINTTELCO CABINET MOUNTED ON 4"X4" TUBE STEEL POST GRADE ••:�fi:�:•:�::❖:•:fi:::�:$•$c_�: ...•_..I•:•I'❖::• :• GRADE ••'•:::':�:�Sk•''�:::Z.Z i :1�:...... Li?-' 00/8' \ •� 24"x36" SCALE: 3/16" = i'—O" ..,- EXISTING SOUTHWEST ELEVATION 1 24"x36" SCALE: 3/16" = 1'-0" PROPOSED SOUTHWEST ELEVATION 2 11"x17" SCALE: 3/32" = 1'-0" 4 2 0 4' 11"x17" SCALE: 3/32" = 1 —0 4' 2 0" 4' THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint). 0 C?AYN •-r- PACIFIC TELECOM SERVICES, LLC 506.2ND AVE. ATTLE,WA 981SURE04 210 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 95175 KING COUNTY ISSUE DATE 02-26-14 ISSUED FOR CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INIVAS A 01/30/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-1&1= 4004 SHEET TTILE EXISTING & PROPOSED SOUTHWEST ELEVATION SHEET NUMBER A-6 REVISION: 0 SE03XC408 IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint) MECHANICAL DOWNTILT 12.0 BRACKET 4.3 Power Junction Cylinder _ Connector Shape Steel bene point (20nYn) PANEL ANTENNA WITH MOUNTING HARDWARE ANTENNA PIPE MOUNT, SAMSUNG OR `,1—� MOUNTING PIPE (LENGTH TO SUIT) 2.5 GHz RRH FIBER k Fiber Junction Cylinder ISSUE DATE 02-26-14 ' REVISIONS REV. DATE DESCRIPTION \ A 01/30/14 \ Oj Ffta hC zanduct 5� 0 — AL APPROVED EQUAL RRH MOUNTING HARDWARE, SAMSUNG OR APPROVED EQUAL , EXISTING 11111 POWER CABLES FlBER k POWER CABLES FROM FROM RF CABINET MANUFACTURER: KMW COMMUNICATIONS,! MODEL ET-X-WM-18-65-8P (2.SGH2) WEIGHT: 36.4 LBS DIMENSIONS (LBWBD): 61.0" X 12.0" X 4.3" FREQUENCY: REFER TO RF DATA SHEEP Si A 7/ _ I • 1 .,I,a,. Fr, _ . •!�1 ''_� /, r. ii Li �, .. cit r'0Cv 10 �_� 30 V ., F 12.0 12.0 0 MOUNTING FRAME -KID '1 ,T'1 Off` aw 30 I I l f T'1' .I LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND 1 STATE OF WASHINGTON REN. 02-18-15 ..0011 SHEET TITLE EQUIPMENT DETAILS u�_ REVISION: 0 1.+�er Y` \ '� -4BV a Buchu .. Bushar );•±cS/ y 261 '� �, . 9• 00.11 ■I— ill FIBER de POWER CYLINDERS. CONTRACTOR SHALL MOUNT WITH ADEQUATE HARDWARE _ n `rd 1 G� 1 20C w �Twy'> liri L� K�b Kfb} Ma BOTTOM 200 ,k7F ,lr RF CONNECTOR, TYP REMOTE ELECTRICAL ' NOTE: VERIFY EXISTING CONDITIONS -allinlila ALL MOUNTING CLAMPS AND HARDWARE SHALL BE VERIFIED BY TOWER ACCESSORY MANUFACTURER TO EXISTING FRAME. JUMPER (TYP.) ^pi1 OON°r aur Gla. ws•7. .— vnbrOwOf'- :�, 7 Q 0 DOWNTILT ACTUATOR, TYP .. .• \ \ 22•x34" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE MOUNTING DIAGRAM'. 1 22•x34• SCALE: NOT TO SCALE 11 " x17 " SCALE: NOT TO SCALE 2.5GHZ ANTENNA 2 22•x34• SCALE: NOT TO SCALE FIBER JUNCTION CYLINDER 11•x17" SCALE: NOT TO SCALE 3A 22"x34• SCALE: NOT TO SCALE 11•x17• SCALE: NOT TO SCALE POWER. JUNCTION CYLINDER 3B MOUNTING BRACKET AND HARDWARE - 15.5 Sprint STBR 2.5G STBR radar filler 2496-2690MHz Spn11 STBR2 SO radar tiller consists 01 Neluni9I badpass litter. 8 channel Designed for ami.imerfercnte. • Suitable for indoor or outdoor appli:dfwn. nn.: Seoeilialn -- -- - - - - — - furs lvmd 7:191-,-.1690 NOV: •A hoe:bort Loss 406411 (AiLe.,e for a IDMI h 421 i'I < q17 dH (A.'a:901Iia inn InMIL•411V—K3 14'1 � - I'uwiLul l<gple gin] 1111 i r aclumloSs IS Jai +?)1' >14 dlt-luC-.ssr .. p SAMSUNG OR APPROVED EQUAL SPFCIFICATIONS ANTENNA MECHANICAL IH} { 111 I 1 11 11 111 11 11, MOUNTING PIPE HxWxD: 382x584x240mm (18.6"x15.5 -x9.45') III III 11 11111111 < ANTENNA 11 MOON MOUNTING PIPE MOUNTING BRACKET WEIGHT: 59.5 LBS I i1111111111111111 I11111111 AND HARDWARE - SAMSUNG OR APPROVED 9.45 PLAN EQUAL t'!rw uliuull tn m o co li' i! j III III I I I 1 !:°:°0%:20°°.:0::::.°:20°0%°: I' !•i I, !I III °• aaaaaaaaaa°aaa° ¢ I ILII I IIII to j i LT.'ca, °°°° a° t. of ' o°° o° o ° 0 0 0 ° °a MOUNTING AND HARDWARE SAMSUNG BRACKET - OR _ ,,,I �' 00°1°0°o °a 0 ° o ° a ° ° o ° o°°°O°°°°°° ° ° ° ° ° 00°01 ° °°° a o a a a a a a ° O ° ° alk lur:wu +« dB ,.27x1-2941". MW _ U. .,kla• <41 ns V24'96-2690 MIS tmxe 41: til ._15'. 1.145 Imp. roma 90 w (As, .xsL liana altitude, 201nn all4 1a, 0 0..1, .9913 112011m44411 1.1.men 1,141, ,111 (Am 1/,o Nth: 0 � APPROVED EQUAL III • 17 d ❑ G G C 1:f I:1 ANTENNA 1 .tut MOUNTING PIPE r� SIDE FRONT 22"x34" SCALE: NOT TO SCALE 11"x17• SCALE: NOT TO SCALE RRMOUNTING22•x34• 4H SCALE: NOT TO SCALE 2.5GHZ RRH-V3 11•x17" SCALE: NOT TO SCALE 5 Into -modulation < -120 dlic i1" orJ¢ „illi .1> 4:1411m1 ^1 '".. INroln'n,y J.mee RI st r 1"Y boon Ing letup:Mum -11/11-•1SSl' o. - LNMowninp Options. 0 J; 1 n Rad:Y6ttcr Como:t°n 1mmdNN f ale Vit; L x Bakelite .kvdwxaln iNan ° aul,lr,r •- (:i: ,I n 6unlalion Bushing '4eV"•.y We1,JG can kg t , �- q 4 ♦Boll: AIB s 25 Dimensions i117'r:2nii:77mn a• N•_ ON incline eeannq te.le11 I x WaShing:Alx - _ <; '1. X Scmw: N112s ?S1/ (•. I .X Bmckcl L.sNl1I: M12 O —, -no v. O . `. O a ' ■ep„ EQUIPMENT RF URDU -ANTENNA per, 'I ED — �I •• 4) FlBER POWER AND DC CABLES 5) CPRI CABLE T — •R R . , `— U 1 00,80TGB JUNCTION CYUNDERS I'p 6) RET CABLE i111111IIIIJ•LIIIIIIIIPIIIII '1 ,JIIIIIDIIIIIIIIIIIIIIIIIOIIIII 3) RRH GROUND CABLE 7) RF JUMPERS FEEDER UNE GROUND CABLE (GROUND KIT/7/8 IN. FEEDER UNE OR MORE) MGB "1) MGB GROUND CABLE N AND GROUND ARE USED IN CASE OF THE 7/8 IN. FEEDER ER LINE OR MORE 22"x34" SCALE: NOT TO SCALE 11"x17• SCALE: NOT TO SCALE SAMSUNG MMBS WIRING DIAGRAM 6 22•x34" SCALE: NOT TO SCALE 11"x17• SCALE: NOT TO SCALE FILTER SPECIFICATIONS 7 IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint) 0 cc8A°9ffiE`i PACIFM TELECOM SERVICES. LLC 5013 SE2NDATf1E, WAVE, A 9015UITE04 210 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY ISSUE DATE 02-26-14 ISSUED FOR CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INITIALS A 01/30/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND 1 STATE OF WASHINGTON REN. 02-18-15 ..0011 SHEET TITLE EQUIPMENT DETAILS SHEET NUMBER A-7 REVISION: 0 SE03XC408 TYPICAL HYBRID CABLE COLOR CODE SECTOR FIRST RING SECOND RING THIRD RING A GREEN NO TAPE NO TAPE B GREEN GREEN NO TAPE G GREEN GREEN GREEN FREQUENCY COLOR CODE FOR PAIRS AND FIBER CABLES OF HYBRID CABLE FREQUENCY COLOR CODE FIRST RING SECOND RING 1900 MHz YELLOW RED TYPICAL JUMPER CABLE COLOR CODE FREQUENCY ANTENNA PORT RRU PORT CABLE COLOR 1900 MHz PCS1 -45' ANT 0 BLUE PCS1 +45' ANT 1 WHITE PCS2 -45' ANT 2 GREEN PCS2 +45' ANT 3 BROWN RET RET RED NOTES ON HIGH CAPACITY SITES OR ON FOUR -SECTOR SITES NEEDING AN ADDITIONAL UNE AND RRU CONTACT GDR SITE SUPERVISOR FOR COLOR CODE INFORMATION ON ADDITIONAL LINES. SUPPLIER SAMSUNG FIBEROPTICS ASIA TAI TYPE LENGTH TOTAL WEIGHT WEIGHT/LF TOTAL WEIGHT WEIGHT/LF (FT) (KG) (LBS) (KG) (LBS) (KG) (LBS) (KG) (LBS) TYPE 1 60 13 28 0.2 0.5 19 41 0.3 0.7 75 16 35 0.2 0.5 22 49 0.3 0.7 90 19 42 0.2 0.5 26 57 0.3 0.7 TYPE 2 105 30 66 0.3 0.6 29 65 0.3 0.7 120 34 75 0.3 0.6 33 73 0.3 0.7 135 38 85 0.3 0.6 46 101 0.3 0.7 150 43 94 0.3 0.6 51 112 0.3 0.7 165 47 104 0.3 0.6 55 122 • 0.3 0.7 TYPE 3 180 69 151 0.4 0.8 72 160 0.3 0.7 195 75 164 0.4 0.8 78 173 0.3 0.7 210 80 177 0.4 0.8 85 187 0.3 0.7 TYPE 4 225 89 196 0.4 0.9 102 224 0.3 0.7 240 95 209 0.4 0.9 109 239 0.3 0.7 255 101 222 0.4 0.9 115 254 0.3 0.7 TYPE 5 270 133 293 0.5 1.1 122 270 0.3 0.7 285 141 310 0.5 1.1 152 335 0.3 0.7 300 148 326 0.5 1.1 160 353 0.3 0.7 315 155 342 0.5 1.1 168 371 0.3 0.7 330 163 359 0.5 1.1 176 388 0.3 0.7 TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6 TYPE 7 TOTAL LENGTH -114.-9.95" -'180'-5.35" -213'-3.05" "262'-5.60" «328'-1" «420'-0" -'550'-0" HYBRID POWER CABLE CONFIGURATION AWG 10 1 PAIR, AWG 12 3 PAIR AWG 8 1 PAIR, AWG 10 3 PAIR AWG 6 1 PAIR, AWG 8 1 PAIR, AWG 10 2 PAIR AWG 6 1 PAIR, AWG 8 3 PAIR AWG 4 1 PAIR, AWG 6 1 PAIR, AWG 8 2 PAIR AWG 4 1 PAIR, AWG 6 3 PAIR AWG 2 1 PAIR, AWG 4 3 PAIR CABLE DIAMETER 0.98" 1.06" 1.18" 1.18"/1.25" 1.25" 1.56" 1.69" BENDING RADIUS 11.81" 12.99" 15.35" 17.71" 17.71" 18.00730.00" 21.00735.00" OPTIC CABLE LC/PC-to-LC/PC, SINGLE MODE DU CABINET (POWER CABLE TERMINAL MAX SIZE AWG 4) 2 PAIR POWER AND OPTIC CABLE WITH PE PIPE RRU POWER CABLE SPEC AWG 8, 0.57""0.60" AWG 10, 0.45"-'0.48" 8 AWG CABLES 4 PAIRS NON USE POWER AND OPTIC CABLE PROTECTION 2 PAIR POWER AND OPTIC CABLE WITH PE PIPE 2 PAIR POWER AND OPTIC CABLE WITH PE PIPE 2 PAIR POWER AND OPTIC CABLE WITH PE PIPE 2 PAIR POWER AND OPTIC CABLE WITH PE PIPE 2 PAIR POWER AND OPTIC CABLE WITH PE PIPE 2 PAIR POWER AND OPTIC CABLE WITH PE PIPE SUPPLIER TESSCO TYPE LENGTH TOTAL WEIGHT (FT) (KG) (LBS) ISSUED FOR: CONSTRUCTION DWGS REVISIONS 1 0.73 1.6 TYPE 6 1000 732 1613 AF 420 402 887 AF 1 1 2.2 TYPE 7 1000 1006 2218 550 553 1220 22"x34" SCALE NOT TO SCALE HYBRID AND JUMPER CABLES COLOR CODING 11"x17" SCALE NOT TO SCALE 1 22"x34" SCALE NOT TO SCALE 11"x17" SCALE NOT TO SCALE HYBRID CABLE TYPES 2 (4) PAIR COPPER TO RRU (6) FIBER CABLES 2" TAPE 1" SPACE FIRST RING BETWEEN HYBRID COLOR CODE . RINGS 2" TAPE SECOND RING (IF APPLICABLE PER SECTOR) 1" SPACE BETWEEN RINGS 2" TAPE THIRD RING (IF APPUCABLE PER SECTOR) 2" SPACE BETWEEN HYBRID CABLE COLOR CODE AND FREQUENCY COLOR CODE 2" TAPE FIRST RING FREQUENCY COLOR CODE 2" TAPE SECOND RING FREQUENCY COLOR CODE 2" SPACE FROM END OF BREAK-OUT CYLINDER HYBRID COLOR CODE TAPE (SEE TABLE FOR DETAILS) (4) PAIR COPPER TO CABINET (6) FIBER CABLES HYBRID COLOR CODE TAPE (SEE TABLE FOR DETAILS) 2" TAPE 1" SPACE FIRST RING BETWEEN HYBRID COLOR CODE . RINGS HYBRID COLOR CODE TAPE (SEE TABLE FOR DETAILS) 2" TAPE SECOND RING (IF APPLICABLE PER SECTOR) 1" SPACE BETWEEN RINGS 2" TAPE THIRD RING (IF APPLICABLE PER SECTOR) NO SPACE BETWEEN CABLE 2" SPACE BETWEEN HYBRID CABLE COLOR CODE AND FREQUENCY COLOR CODE 2" TAPE FIRST RING FREQUENCY COLOR CODE FREQUENCY COLOR CODE (SEE TABLE FOR DETAILS) 2" TAPE SECOND RING FREQUENCY COLOR CODE 2" TAPE RING 2" TAPE RING 1" SPACE SECOND RING 1" SPACE THIRD RING 2" TAPE RING BETWEEN (IF APPUCABLE PER BETWEEN (IF APPUCABLE PER FIRST RING RINGS SECTOR) RINGS SECTOR) HYBRID COLOR CODE TAPE (SEE TABLE FOR DETAILS) 2" SPACE FROM END OF BREAK-OUT CYLINDER HYBRID COLOR CODE TAPE (SEE TABLE FOR DETAILS) WRAP TAPE AROUND CABLE. THREE TIMES, MIN. (TYP) HYBRID CABLE TO CABINET 2" TAPE RING 2" TAPE RING 1" SPACE SECOND RING 1" SPACE THIRD RING 2" TAPE RING BETWEEN (IF APPLICABLE PER BETWEEN (IF APPLICABLE PER FIRST RING RINGS SECTOR) RINGS SECTOR) HYBRID COLOR CODE TAPE (SEE TABLE FOR DETAILS) NOTE: HYBRID COLOR CODE TAPE (SEE TABLE FOR DETAILS) HYBRID COLOR CODE TAPE (SEE TABLE FOR DETAILS) 1. ALL CABLES SHALL BE MARKED AT THE TOP AND BOTTOM WITH 2" COLORED TAPE OR STENCIL TAG. COLOR TAPE SHALL BE OBTAINED FROM GRAYBAR ELECTRIC. 2. THE FIRST RING SHALL E CLOSEST TO THE END OF THE CABLE AND SPACED APPROXIMATELY 2" FROM AN END CONNECTOR, WEATHERPROOFING, OR BREAK-OUT CYLINDER, WITH 1" SPACE BETWEEN EACH RING. 3. THE HYBRID CABLE COLOR SHALL BE APPUED IN ACCORDANCE WITH THE "TYPICAL HYBRID CABLE COLOR CODE" TABLE ABOVE FOR THE RESPECTIVE SECTOR. 4. INDIVIDUAL POWER PAIRS AND FIBER CABLES SHALL BE LABELED WITH BOTH THE HYBRID CABLE COLOR FOR THE RESPECTIVE SECTOR AND A FREQUENCY COLOR CODE IN ACCORDANCE WTTH THE "FREQUENCY COLOR CODE FOR PAIRS AND FIBER CABLES OF HYBRID CABLE" TABLE ABOVE. 5. A 2" GAP SHALL SEPARATE THE HYBRID CABLE COLOR CODE FROM THE FREQUENCY COLOR CODE. 6. THE 2" COLOR RINGS FOR THE FREQUENCY CODE SHALL BE PLACED NEXT TO EACH OTHER WITH NO SPACES. 7. THE 2" COLORED TAPE(S) SHALL EACH BE WRAPPED A MINIMUM OF 3 TIMES AROUND THE HYBRID CABLE OR INDIVIDUAL CABLES, AND THE TAPE SHALL BE KEPT IN THE SAME LOCATION AS MUCH AS POSSIBLE. 8. COLOR BAND ON JUMPERS SHALL 8E 2" WIDE WITH A 2" SPACE. NO SPACE BETWEEN CABLE FREQUENCY COLOR CODE (SEE TABLE FOR DETAILS) HYBRID CABLE CONNECTION AT CABINET HYBRID COLOR CODE TAPE (SEE TABLE FOR DETAILS) 2 FROM RRU t 2" TAPE SECOND RING FREQUENCY COLOR CODE HYBRID COLOR CODE TAPE (SEE TABLE FOR DETAILS) WRAP TAPE AROUND CABLE. THREE TIMES, MIN. (TYP) 2" TAPE 2" SPACE FIRST RING BETWEEN CABLE CODE FREQUENCY COLOR AND FREQUENCY CODE COLOR CODE HYBRID CABLE TO RRU 2" TAPE THIRD RING CABLE # 1" SPACE 1" SPACE 2" TAPE THIRD RING CABLE # 2" SPACE BETWEEN CABLE CODE AND FREQUENCY COLOR CODE 2" TAPE FIRST RING FREQUENCY COLOR CODE 2" TAPE SECOND RING FREQUENCY COLOR CODE 1 RRU & END OF JUMPER D ANTENNA END OF JUMPER JUMPER CABLE CONNECTION AT RRU AND ANTENNA 1 FROM ANTENNA L/4 -0o/8' 22"x34" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE HYBRID CABLE COLOR SCHEME DETAIL 3 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint). 0 CC8/61(.471V -1- pAcirm TELECOM SERVICES. LLC 506 2ND AVE. SURE 210 SEATTLE. WA 86104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL, S TUKWILA, WA 98178 KING COUNTY ISSUE DATE 02-26-14 ISSUED FOR: CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INITIALS A 01/30/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-18-1= 000.4 SHEET TITLE ANTENNA AND CABLE COLOR CODING DETAILS SHEET NUMBER: RF -1 REVISION: 0 SE03XC408 LEGEND 0 CCI?A?57WL EN EXISTING SPRINT ANTENNA GROUND BAR (1 PER SECTOR, 3 TOTAL)/I `11 \ -......, \ \ \ 11----;1111:"--- \'11111 e \\ \ \ \ `�� l\I! , ��II\\ I Ili \1 .- / 1 ° / 1Ifni' / / / / v/ yrf; / e I II .;:,,I��I I�' ° \ \ \ \ \ X. \ \ -" J \ \ \ \ \ \ \ \\ \ �� ;Il ° \ \ c\'•°• \ ;1111111' \ \ a `• A „L� I•,` • tl"( NEW SPRINT ANTENNA REVISIONS 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES. 3. ALL GROUND CONNECTIONS SHALL BE EXOTHERMIC. ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE. GROUNDING AND OTHER OPERATIONAL TESTING WILL BE WITNESSED BY SPRINT WIRELESS REPRESENTATIVE. 5. REFER TO DMSION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY Wm -I ALL REQUIREMENTS OF GROUNDING STANDARDS. 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING SYSTEM PER SPRINT STANDARD GROUNDING METHOD, AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED SPRINT WIRELESS REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING SYSTEM. PHOTO DOCUMENT ALL EXOTHERMIC AND GROUND RING 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALUNG GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. 8. ALL EXISTING GROUND BARS, WIRES & CONNECTIONS SHALL BE FIELD VERIFIED. ANY DEFICIENT ITEMS SHALL BE REPLACED AS REQUIRED TO ACHIEVE ADEQUATE GROUNDING REQUIRED BY SPRINT. MOUNTING PIPE CONNECTED TO EXISTING ANTENNA GROUND BAR (1 PER SECTOR, 3 TOTAL) NEW SPRINT RRU CONNECTED TO EXISTING ANTENNA GROUND BAR (1 PER SECTOR, 3 TOTAL) CONNECTION FROM NBARS INRNLS A GENERAL GROUNDING NOTES SPRINT ANTENNA GROUD TO EXISTING MASTER GROUND BAR GROUNDING NOTES 1. EXOTHERMIC WELDS (2). 2 AWG BARE TINNED SOLID COPPER CONDUCTORS TO GROUNDING BAR. ROUTE CONDUCTORS TO BURIED GROUNDING RING AND PROVIDE PARALLEL EXOTHERMIC WELD. 2. EC SHALL USE PERMANENT MARKER TO DRAW THE LINES BETWEEN EACH SECTION AND LABEL EACH SECTION ("P", "A", "N", "I") WITH 1" HIGH LETTERS. WASHERS, COAT ALL SURFACES WITH AN ANTI -OXIDANT COMPOUND BEFORE MATING. ALL HARDWARE SHALL BE STAINLESS STEEL 3/8 INCH DIAMETER OR LARGER. 4. FOR GROUND BOND TO STEEL ONLY: INSERT A CADMIUM FLAT WASHER BETWEEN LUG AND STEEL, COAT ALL SURFACES WITH AN ANTI -OXIDANT COMPOUND BEFORE MATING, 5. NUT & WASHER SHALL BE PLACED ON THE FRONTSIDE OF THE GROUNDING BAR AND BOLTED ON THE BACK SIDE. INSTALL BLACK TERMI ATIIONSING THE INTENT OIS VOTO WEATHERPROOF THE LT INSULATION ON ALL GROUNDING COMPRESSION CONNECTION. 6. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATION, AND CONNECTION ORIENTATION. PROVIDE AS REQUIRED. 7. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 8. WEATHERPROOFING SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 9. SUPPLIED AND INSTALLED BY CONTRACTOR. 10. WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OF A GROUNDING BAR TO AN EXISTING TOWER, THE SUBCONTRACTOR SHALL OBTAIN APPROVAL FROM THE TOWER OWNER PRIOR TO MOUNTING THE GROUNDING BAR TO THE TOWER. 11. EXTEND TWO (2) 2 AWG TINNED CU CONDUCTOR FROM BURIED GROUNDING RING AND CONNECT TO THE NEW TOWER. FOLLOW MANUFACTURERS RECOMMENDATIONS FOR GROUNDING CONNECTIONS TO THE TOWER. (APPLICABLE TO NEW TOWERS ONLY.) 12. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATION, AND CONNECTION ORIENTATION. THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ADDITIONAL GROUNDING BARS AS REQUIRED, PROVIDING 50% SPARE CONNECTION POINTS. 13. EXPOSED GROUND WIRES TO BE NON METALLIC LIQUID TIGHT. Lill.. 00/g BAR AEXISTIT GROUSPRINT MASTND LEVELR GROUND EXISTING FINAL GROUND LEAD FROM MASTER GROUND BAR TO EXISTING MONOPOLE GROUND RING TRUE MAGNETIC NORTH NORTH = ARC 0 • EXOTHERMIC CONNECTION ❑ MECHANICAL CONNECTION o COMPRESSION CONNECTION CGB COLLECTOR GROUND BAR MGB EXTERNAL GROUND BAR 24"x36" SCALE: 1/2" = 1'-0" I I ANTENNA SCHEMATIC GROUNDING PLAN 1 11"x17" SCALE 1/4" = 1'-0" 2' � i 0" 2' NOT USED 2 NOT USED 3 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint), 0 CCI?A?57WL EN --i— PACIFIC te PACIFIC TELECOERVICES, LAS 506 2ND AVE, SURE 210 SEATTLE. WA 98104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL S TUKWILA; WA 98178 KING COUNTY ISSUE DATE 02-26-14 IssuEDFOR CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INRNLS A 01/30/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T ' THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-18-15 _ v l SHEET TITLE ANTENNA SCHEMATIC GROUNDING PLAN SHEET NUMBER E-1 REVISION: 0 SE03XC408 LIST. CGB (ANTENNA SECTOR 11 EXISTING PROPOSED 900 MHz 2.5 GHz ANTENNA ANTENNA TCOAX JUMPER HYBRID CABLE INTERNAL 1 GRD WIRE TO BE TRIMMED TO FIT AND ATTACHED TO GRD BAR --i �E2 AWG EXISTING GPS ANTENNA #10 AWG ce m ce 8 0 0 EXIST. CGB JUNCTION CYLINDERS (E) HYBRID MEDUSA (ANTENNA SECTOR 21 EXISTING 900 MHz ANTENNA PROPOSED 2.5 GH ANTENNA COAX JUMPER 0 HYBRID CABLE INTERNAL GRD WIRE TO BE TRIMMED TO FIT AND ATTACHED TO GRD BAR (E) #2 AWG EXISTING UPPER TOWER GROUND BAR #10 AWG — (E) HYBRID MEDUSA `^IST. CGB —JUNCTION CYLINDERS m [ANTENNA SECTOR 31 EXISTING 900 MHz ANTENNA PROPOSED 2.5 GH ANTENNA HYBRID CABLE INTERNAL GRD WIRE TO BE TRIMMED TO FR AND ATTACHED TO GRD BAR [COAX JUMPER `JUNCTION CYUNDERS ...JEL#WC 0 0 EXISTING DEI CABINET EXISTING CABINET EXISTING MMBS CABINET 7 #6 AWG WITH WEATHERPROOFING (E) #2 AWG #2 AWG az aE1 a 1 00 00 00 EMMBS GND BAR HYBRID CABLE INTERNAL GRD WIRE TO BE TRIMMED TO FIT AND ATTACHED TO GRD BAR EXISTING LOWER TOWER GROUND BAR EXISTING #2 AG GROUNDS TO EXISTING GROUND RING EXISTING #2 AG GROUNDS TO EXISTING GROUND RING C14-00/8° (E) HYBRID MEDUSA LEGEND • EXOTHERMIC CONNECTION ❑ MECHANICAL CONNECTION o COMPRESSION CONNECTION CGB COLLECTOR GROUND BAR MGB EXTERNAL GROUND BAR GROUNDING NOTES 1. ALL GROUNDING CONNECTIONS SHALL BE MADE BY MECHANICAL CONNECTION. ALL CABLE TO GROUND RODS, GROUND RODS SPLICES AND LIGHTING PROTECTIONS SYSTEM AS INDICATED. GROUND FOUNDATION ONLY AS INDICATED BY PM. ALL MATERIALS USED SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND PROCEDURES. GROUND CONDUCTOR SHALL HAVE A MINIMUM 24" BENDING RADIUS. 2. ALL MECHANICAL CONNECTIONS ON GALVANIZED SURFACES SHALL BE CLEANED THOROUGHLY AND COLORED TO MATCH SURFACE WITH (2) TWO COATS OF GALVITE (WHITE) PAINT. OR SILVERBRITE (ALUMINUM), 3. ALL ELECTRICAL & MECHANICAL GROUND CONNECTIONS SHALL HAVE ANTIOXIDANT COMPOUND APPLIED TO CONNECTION. 4. GROUND TESTS SHALL BE PERFORMED AS REQUIRED BY SPRINT STANDARD PROCEDURES. GROUND GRID RESISTANCE SHALL NOT EXCEED 5—OHMS. 5. CONTRACTOR SHALL SUBMIT THE GROUND RESISTANCE TEXT REPORT AS FOLLOW: 1. ONE (1) COPY TO OWNER REPRESENTATIVE 2. ONE (1) COPY TO ENGINEER 3. ONE (1) COPY TO KEEP INSIDE EQUIPMENT INCLOSURE 6. ALL RADIO EQUIPMENT AND UTILITY CABINETS GROUNDS LEADS TO BE #2 AWG STRANDED GREEN JACKETED FROM BUSS TERMINAL. 7. ALL ANTENNA MOUNT GROUNDS SHALL BE #2 AWG STRANDED GREEN JACKETED CABLE GROUNDS SHALL BE BLACK FROM MFR. 8. ALL GROUND WIRES FROM GROUND BARS TO GROUND SHALL BE #2 AWG SOLID BARE AS REQUIRED. 9. ALL ABOVE GROUND WIRES SHALL BE GREEN JACKETED. ALL GROUND WIRE'S PENETRATING INTO GROUND AND BELOW SHALL BE SOLID BARE. TOWER GROUNDING STANDARD 1. EXISTING HOME RUN GROUND WIRES TO BE REMOVED. 2. ALL EXISTING AND EXISTING TOWER GROUND BARS TO BE MECHANICALLY ATTACHED TO TOWER WITHOUT INSULATORS. 3. NO DRILLING OR WELDING TO TOWER PERMITTED 22"x34' SCALE: NOT TO SCALE 11'x17" SCALE NOT TO SCALE THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. GROUNDING RISER DIAGRAM 1 Sprint) 0 CC6ATTT? —i— PACIFIC TELECOM5, LLC 506 NO AVE, SUITE 210 SEATTLE, WA 96104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY ISSUE DATE 02-26-14 ISSUED FOR CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INITIALS A 01/30/14 ISSUED FOR 907. CONSTRUCTION AF 0 02/26/14 ISSUED FOR 1005 CONSTRUCTION AF NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND 1 STATE OF WASHINGTON REN. 02-18-15 _ �1 l SHEET TITLE GROUNDING DETAILS SHEET NUMBER: E-2 REVISION: 0 SE03XC408 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint) NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 2. WEATHER PROOFING SHALL BE ANDREWS. (TYPE & PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER.) TO ANTENNAS RXO TXO r` X1 IWEATHERPROOFING 1-1 1-1 KIT (TYP.) to i I/KIT GROUND (TYP.) (SEEANTENNA WEATHERPROOFING DET/3 E-5) KIT •) r 11 SEE NOTE 2 1I1 1I1 ���" ANTENNA CABLE TO SHELTER (TYP.) —ANTENNA GROUND /6 AWG KBAR, SIMILAR TO 166-057! MOUNT 12- TO 24" INSPECTION WINDOW REQUIRED FOR BUTT CONDUCTOR ALL INTERIOR EXTERNAL TWO -HOLE STION UP AGAINST THE ANTENNA CABLE I I ====== WEATHERPROOFING KIT ISSUE DATE: 02-26-14 2 1/2"0 MAX. TOOTHEAD CONNECTORS CONNECTOR 3/8"0x1 1/2" BARREL S/S NUT WASHERS CK WASHER FLATS IM•I IM•I 1' MIN 1/4" MIN (SEE NOTE 3) A 01/30/14 CABLE GROUND KIT #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) (SEE NOTE 1 & 2) AF CONNECTION OF CABLE GROUND KIT TO mSTANDARD ISSUED FOR 100% CONSTRUCTION AF 1 m����I'`'-(2,72 CABLE mCONNECTORCLEAR HEAT NO1E$: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT WITH TWO -HOLE LUG. 3, WEATHER PROOFING SHALL INCORPORATE PPC WEATHERPROOFING TAPE KIT, COLD SHRINK SHALL NOT BE USED. SHRINK im=• I l TINNED COPPER • CLEAR GROUNDING BAR HEAT SHRINK S/S FLAT WASHER S/S BOLT (1 OF 2) "DO NOT DISCONNECT" TAG ON ALL GROUND BAR INTERCONNECTS AND EQUALIZERS #2 AWG STRANDED =11111 GROUND BAR NEAR INSULATED BONDED TOP OF MONOPOLE, TO TOWER STEEL TOWER OR WAVEGUIDE LADDER. OR MONOPOLE 22'x34' SCALE: NOT TO SCALE NOT USED 11"x17" SCALE: NOT TO SCALE 1 22'04* SCALE: NOT TO SCALE ANTENNA GROUND BAR 11" x17" SCALE: NOT TO SCALE 2 22'x34" SCALE: NOT TO SCALE CABLE GROUNDING 7" 11-x1SCALE: NOT TO SCALE 3 22"x34' SCALE: NOT TO SCALE 11"x17' SCALE: NOT TO SCALE 1NVO HOLE LUG 4 �'� PUN 2 HOLE LUG SST "T" SPI ICS 1 STRANDED CU WIRE WITH GREEN. NOTER 600V, THHN/THWN INSULATION. SURFACERAIDEET NO -OX GREASEUANDANDT / BETWEEN LUG GROUND SIZE AS SPECIFIED BAR GROUND LEADS TO NEW PIPE MOUNT, NEW SPRINT ANTENNAS & NEW SPRINT RRU'S LICENSURE: GROUND BAR ON ANTENNA TOWERCRO f SHEET NUMBER: E-3 COAX CABLE GROUND LEADS T j 61114, 1 BOLT PARALLEL UNNERSA BOLTPARALLEL T + \ PPE LAMPS O 00 O• 0000 o• O O O(13 0 0 O2 0000 O OCONNECTIONS. J EXISTING x T HK.,O00OOOOO/TINNED GROUNDBAR & 5P11GE6 PJeEAGCLAMPH2 Cp UNNFRSAL a PIPE CLAMPS BOLT ) GRAD TWO -HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1 1/4"STAINLESS STEEL HEX HEAD BOLTS AND HARDWARE. 75/1,25 ROD CLAMP EXOTHERMIC WELD WITH #2 AWG SOLID TINNED BARE CU WIRE OR STRANDED CU WIRE WITH GREEN, 600V, THHN/THWN INSULATION TO MGB 22"x34' SCALE: NOT TO SCALE TYPICAL MECHANICAL CONNECTIONS 11"x17" SCALE: NOT TO SCALE 5 22"x34' SCALE: NOT TO SCALE ANTENNA GROUND BAR CONNECTIONS 11"x17" SCALE: NOT TO SCALE 6 #6 AWG GREEN STRANDED CU GROUNDING CONDUCTOR FROM RRU UNIT TO #2 AWG GROUNDING CONDUCTOR STRANDED CU WIRE WITH GREEN, 600V, THHN/THWN INSULATION. *PROVIDE NO -OX GREASE AT CONTACT SIZE AS SPECIFIED SURFACE BETWEEN LUG AND GROUND BAR GROUND BAR ON WALL, FLOOR OR ON ANTENNA TOWER — — Lr�fi — — --- GROUND LEADS TO EACH � ANTENNA GROUND BAR COAX GROUND BEADS \ THIN WALL C -TAP W/PINK DYE INDEX (SEE NOTE) / O O — O O 0000000000000000000 0 QO OO 0 Q 0 OO ,_, /.... 0 O O O O O O O O O O O O O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 OO O 0 OOOO O 0 O 0 O O/ & CNG GROUND BAR E CONNECTIONS 011/°'/ .1 #2 AWG STRANDED CU GROUNDING CONDUCTOR NOTE: CONTRACTOR TO SURROUND COMPLETED CONNECTION W/ WEATHER PROOFING TAPE TO ENSURE WEATHER PROOF CONNECTION. u TWO -HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1 1/4"STAINLESS STEEL HEX HEAD BOLTS AND HARDWARE. EXOTHERMIC WELD WITH #2 AWG SOUD TINNED BARE CU WIRE OR STRANDED CU WIRE WITH GREEN, STRUCTURE, TBUILDING,WN INSULATION TO ANTENNA ij RING GROUND OR MGB 0,,ge 11 •• GROUND BARS AT BOTTOM POLES OF TOWERSUSE X THEMORMIC SHALL USE EXOTHERMIC CONNECTION. 22"04" SCALE: NOT TO SCALE NOT USED 11"x17" SCALE: NOT TO SCALE 7 22'x34" SCALE: NOT TO SCALE C -TAP CONNECTION 11"x17• SCALE: NOT TO SCALE 8 22x34" SCALE: NOT TO SCALE TOWER MASTER GROUND BAR CONNECTIONS 11"x17" SCALE: NOT TO SCALE 9 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint) CCYEN -1- PACIFIC 505 2NDCOM AVE. SURE 129, Lac 10 SEATTLE, WA 95104 PROJECT INFORMATION: TUKWILA SE03XC408 / CCI 880338 12400 51ST PL. S TUKWILA, WA 98178 KING COUNTY ISSUE DATE: 02-26-14 ISSUED FOR: CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INRIALS A 01/30/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/26/14 ISSUED FOR 100% CONSTRUCTION AF •NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE: 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-18-15 0.00.3 somom SHEET TITLE GROUNDING DETAILS SHEET NUMBER: E-3 REVISION: 0 SE03XC408