City of Tukwila
Department of Community Development
April 15, 2014
NOTICE OF DECISION
TO: Ronald Meckler
Crown Castle
8432 154th Ave NE
Redmond, WA 98052
Jim Haggerton, Mayor
Jack Pace, Director
This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project
and permit approval.
Project File Number:
Applicant:
Type of Permit Applied for:
Project Description:
Location:
Associated Files:
Comprehensive Plan
Designation/Zoning
District:
I. PROJECT INFORMATION
L14-0018, PL 14-0010
Ron Meckler, Crown Castle (obo Sprint PCS)
Type 1 Wireless Telecommunications Facilities Permit
Approval of a Type I Wireless Telecommunication Facilities
Permit to upgrade existing antennas, cabinets and associated cabling on
an existing wireless facilities tower. No ground disturbance or expansion
of the existing compound is proposed.
Tax Lot NO: 0003800003. This tower is located at 12200 51st Pl. S.,
Tukwila, WA 98178.
N/A
Manufacturing Industrial Center/Heavy Industrial (MIC/H)
II. DECISION
SEPA Determination: The City SEPA Responsible Official has previously determined that this application
does not require a SEPA threshold determination because it is categorically exempt.
Decision on Substantive Permit: The City Community Development Department has determined that the
application for a Type 1 Wireless Communications Facility does comply with applicable City and state code
requirements and has approved that application without conditions.
MB Page 1 of 3 04/15/2014
W:\Users\Max\L14-0017\L14-0018 NOD.doc
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665
III. YOUR APPEAL RIGHTS
The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code
§ 18.104.010. Other land use applications related to this project may still be pending.
No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing
Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to
challenge either the conditions which were imposed by the MDNS decision or the failure of the Department
to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing
Examiner.
A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in
King County Superior Court from the Hearing Examiner's decision.
IV. PROCEDURES AND TIME FOR APPEALING
In order to appeal the Community Development Director decision on the Permit Application, a written
notice of appeal must be filed with the Department of Community Development within 14 days of the
issuance of this decision, that is by April 29, 2014.
The requirements for such appeals are set forth in Tukwila Municipal Code ch. 18.116. All appeal
materials shall be submitted to the Department of Community Development. Appeal materials MUST
include:
1. The name of the appealing party.
2. The address and phone number of the appealing party; and if the appealing party is a corporation,
association or other group, the address and phone number of a contact person authorized to receive
notices on the appealing party's behalf.
3. A statement identifying the decision being appealed and the alleged errors in the decision, including
any specific challenge to an MDNS.
4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in
the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief
sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal.
5. Appeal fee of $541 plus retainer.
V. APPEAL HEARINGS PROCESS
Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the
Hearing Examiner based on the information presented to the Community Development Director, who
made the original decision. No new evidence or testimony will be permitted during the appeal hearing.
Parties will be allowed to present oral argument based on the information presented to the Community
Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is
the City's final decision.
MB Page 2 of 3 04/15/2014
Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal
pursuant to the procedures and time limitations set forth in RCW ch. 36.70C. An appeal challenging a
DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's
decision is properly filed in Superior Court within such time limit, the Decision on this permit will be
final. The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other
pending permit applications for the development of the subject property.
VI. INSPECTION OF INFORMATION ON THE APPLICATION
Project materials including the application, any staff reports, and other studies related to the permits are
available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd.,
Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The
project planner is Max Baker, who may be contacted at 206-431-3662 or via email at
max.baker@tukwilawa.gov for further information.
Property owners affected by this decision may request a change in valuation for their property tax purposes.
Contact the King County Assessor's Office for further information regarding property tax valuation changes.
Department of Community Development
City of Tukwila
MB Page 3 of 3 04/15/2014
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
STAFF REPORT TO THE DIRECTOR
PREPARED April 15, 2014
NOTIFICATION: Notification is not required for a Type I land use application.
FILE NUMBER: L14-0018, PL14-0010
APPLICANT: Ron Meckler, Crown Castle (obo Sprint PCS)
PROPERTY OWNER: Burlington Northern Railway Company
REQUEST: Approval of a Type I Wireless Telecommunication Facilities
Permit to upgrade existing antennas, cabinets and associated cabling on an existing
wireless facilities tower.
LOCATION: Tax Lot NO: 0003800003. This tower is located at 12200 51st Pl. S., Tukwila, WA
98178.
ASSOCIATED
PERMITS: Electrical permits issued through the City of Tukwila will be required for service
alteration for any other electrical service work this is anticipated but not noted on the
plans, per article 85.13 (B), Washington electrical code. Building permit is not required
for scope of work stated on the submitted plans.
SEPA
DETERMINATION: Exempt
COMPREHENSIVE PLAN
DESIGNATION: Manufacturing Industrial Center/Heavy Industrial (MIC/H)
ZONE DESIGNATION: Manufacturing Industrial Center/Heavy Industrial (MIC/H)
STAFF: Max Baker, Planning Intern
ATTACHMENTS: Project Plans for Permit L14-0018
FINDINGS
Vicinity/Site Information
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665
Project Description
The applicant is requesting approval of a Type I Wireless Telecommunication Facilities [WCF] Permit to add equipment
on an existing tower at 12200 51st Ave Pl. S. The project includes:
• Install 2.5 equipment in existing cabinet
• Add (3) antenna (1 per sector)
• Install (3) RRH units (1 per sector)
• Install (6) Junction Cylinders
• Install (3) Filters
The existing cellular tower is 80 feet high with the proposed Sprint antennas to be mounted at 77 feet adjacent to existing
Sprint antennas.
Existing Development
This site is adjacent to Burlington Northern Santa Fe rail yard. In addition to the tower, the site functions as a storage and
staging area for rail containers and includes at least two buildings.
Surrounding Land Uses
The property and the surrounding parcels to the north are zoned MIC/H. To the immediate east are rail lines and freeway.
To the south and west, the adjacent properties are zoned LDR.
BACKGROUND
In 2006, the City adopted a Wireless Facilities Chapter (TMC 18.71) to the Zoning Code. The chapter provides specific
location and design requirements for the placement of WCF within the City of Tukwila.
The WCF being modified was originally approved by the City in 1997 (L97-0030) through a conditional use permit.
In 2012 the WCF was approved for modifications (L12-032) through a Type 1 Wireless facilities permit.
Location Selection
Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co -locations
and utilizing existing structures are favored over the development of new standalone WCF within the City.
TABLE A
Type of Permit Required, Based on
Type of Wireless Communication Facility
ZONING (1)
TYPE OF FACILITY
RESIDENTIAL
COMMERCIAL
INDUSTRIAL
Transmission Tower
co -location
Type 1
Type 1
Type 1
Adding antennas to an existing tower
Type 1(2)
Type 1(2)
Type 1(2)
Utility pole co -location
Type 2
Type 2
Type 2
Concealed building attached
Type 2(3)
Type 2(3)
Type 2(3)
Non -concealed building attached
Type 2
Type 2
Type 1
New tower or waiver request
Type 4
Type 4
Type 4
SM
(1)
Zoning for any private/public property or right-of-way
Residential — LDR, MDR, or HDR
Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS
Industrial - LI, HI, MIC/L, or MIC/H
(2) Provided the height of the tower does not increase and the square footage of the enclosure area does not
increase.
Page 2 of 5
04/15/2014
(3) An applicant may request to install a non -concealed building attached facility, under TMC Section 18.58.150.
The applicant is adding additional antennas to an existing tower. This decision does not require the use of any new
facilities for placement of the new antennas.
Design Standards
The City provides specific design standards for the placement of WCF within the City of Tukwila. The table below
indicates if the applicant's proposal complies with required standards.
Table 1(See TMC 18.58.070 for further details
General Requirements
Project
does
comply
Project
does
not
comply
Not
Applicab
le
Notes
1. Generators or other
devices which will create
noise must comply with TMC
8.22 regarding noise.
X
The applicant has not proposed a new generator.
2.Business License
Requirement
X
Sprint has applied for a business license (00008547)
3. Only safety signage must
be placed on the WCF.
X
The applicant does not propose any signage.
4. Accommodations for
parking for maintenance
personal must be provided.
X
Parking is not affected by this modification.
5. Towers shall either
maintain a galvanized steel
finish or be painted a neutral
color so as to reduce its visual
obtrusiveness.
X
No change to the existing tower is proposed.
6. The design of all buildings
and ancillary structures shall
use materials, colors,
textures, screening, and
landscaping that will blend
the tower facilities to the
natural setting and built
environment.
X
No new buildings or structures are proposed.
7. Antennas shall have the
same color scheme as the
structure they are located on.
X
The existing pole is galvanized steel. No change to the
color of the existing antennas and equipment is proposed.
The current equipment color blends with the pole color.
8. WCF poles and towers
shall only have safety lights if
required by a government
agency.
X
No lighting is proposed.
9. No advertising is
permitted on WCF
X
No advertising is proposed.
10. Each service provider
shall be limited to an
equipment enclosure of 360
square feet.
X
No change to the existing equipment enclosure is
proposed.
SM
Page 3 of 5
04/15/2014
Table 2 (See TMC 18.58.090 for additional information)
Adding Antennas to
Existing WCF Tower-
Specific Development
Standards
Project
does
comply
Project
does
not
comply
Not
Applicab
le
Notes
1. When adding antennas to
existing WCF towers, height
must not exceed what was
approved under the original
application to construct the
tower.
X
No change to the previously approved tower height of 80'
is proposed.
2. Antennas shall be painted
to match the color scheme of
tower.
X
Antennas and ancillary equipment will be painted to
match the existing tower color.
3. There is no limit on the
number of antennas that may
be located on an existing
tower.
X
4. Feed lines and coaxial
cables shall be located within
the tower. Those exposed
shall be painted to match
tower.
X
Cables shall be routed within the tower. The jumper
cables will be painted to match the antennas.
5. A new cabinet shall be
located within the equipment
enclosure that was approved
as part of the original
application, or it will require
a Type 2 decision.
X
No new cabinets are to be installed.
6. Setbacks shall not apply
when an applicant installs
new antennas on an existing
tower and uses an existing
equipment enclosure. If the
equipment enclosure is
increased, it must meet
setbacks.
X
There is no change to the existing equipment enclosure.
SM
CONCLUSIONS
1. The proposed modifications to the existing antenna will not significantly alter the conditions that currently exist
and will not be materially detrimental to the public welfare or injurious to property or improvements in the
vicinity.
2. As demonstrated in Tables 1 and 2, the project meets all applicable development standards for a Type 1 WCF.
3. The proposed modifications will not alter the surrounding land uses in terms of traffic and pedestrian circulation,
building or site design.
Page 4 of 5 04/15/2014
4. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy Plan.
RECOMMENDATIONS
The recommendation to the Director of Community Development is to approve this application for a Type I Wireless
Telecommunication Facility permit as applied for by Crown Castle for Sprint without conditions.
INFORMATIONAL ITEMS
A City of Tukwila electrical permit is required for service alteration. Please note that the installation of an emergency
power disconnect switch is required for fire department use. Contact Don Tomaso at 206-971-8723 to get more
information about permit requirements for the power disconnect switch.
SM Page 5 of 5 04/15/2014
fi\)
CcYE
3/6/2014
MAR 10 2014
City of Tukwila
Department of Community Deivelopxmermtwr
6300 Southcenter Blvd.
Tukwila, WA 98188
Re: Project Description
Sprint 2.5
Site SE03XC408 TUKWILA
12200 51ST Place S
Crown Castle
Ron Meckler
8547 154th Avenue NE
Redmond, WA 98052
Tel: 425-202-2763
Mobile: 206-384-2454
Fax: 724-416-6261
Ronald.Meckler@crowncastle.com
My name is Ron Meckler and I am a planning consultant with Crown Castle for zoning and permitting
services. Our client, Sprint PCS, is in the process of a national update and modernization of its wireless
service. The project requires adding 3 antennas to an existing aray, No change to tower height or ground
space.
A summary of the work planned for this site is:
• Install 2.5 equipment in existing cabinet
• Add (3) Antennas(1 per sector)
• Install (3) RRH units (1 per sector)
• Install (6) Junction Cylinders (2 per sector)
• Install (3) Filters
THE HEIGHT OF THE EXISTING TOWER WILL NOT BE INCREASED, NOR WILL THE FOOTPRINT
OF THE EXISTING EQUIPMENT COMPOUND BE CHANGED.
Crown Castle is the owner and operator of the wireless facility at the above address. Crown Castle
believes the existing structure will comply with all FAA regulations and applicable standards with the
improvements and alterations proposed in this permit application.
Furthermore, Crown Castle states that the proposed installation, repair, operation, upgrading,
maintenance and removal of antennas shall be lawful and in compliance with all applicable laws, orders,
ordinances and regulations of the state, and local authorities having jurisdiction.
Crown Castle further agrees to remove the facility within one year after all of the site's tenants discontinue
use of the facility or the facility falls into disrepair, and restore the site to its pre-existing condition.
Thank you for your assistance.
Sincerely,
Ronald M k ' operty Specialist
p Y P
West Area
rJ
Date: December 20, 2013
Michael Murray
Crown Castle
5350 North 48th Street, Suite 305
Chandler, AZ 85226
(480) 734-2422
Subject:
Carrier Designation:
Crown Castle Designation:
Engineering Firm Designation:
Site Data:
Dear Michael Murray,
Glaus, Pyle, Schomer, Burns &
DeHaven, Inc., dba Glaus, Pyle,
Schomer, Burns & DeHaven, PC
520 South Main Street, Suite 2531
Akron, OH 44311
(614) 859-1607
dpalkovic@gpdgroup.com
Structural Analysis Report
Sprint PCS Co -Locate
Carrier Site Number:
Carrier Site Name:
Crown Castle BU Number:
Crown Castle Site Name:
Crown Castle JDE Job Number:
Crown Castle Work Order Number:
Crown Castle Application Number:
Scenario 2.5B
SE03XC408
TUKWILA
880338
TUKWILA
253287
686043
206598 Rev. 1
GPD Group Project Number: 2013777.880338.03
12400 51ST PL. S, TUKWILA, WA 98178, King County
Latitude 47°29'37.52'; Longitude -122° 16' 14.19"
80 Foot — Valmont Monopole Tower
Glaus, Pyle, Schomer, Burns & De Haven, Inc. dba Glaus, Pyle, Schomer, Burns & De Haven, PC (GPD Group)
is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above
mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural `Statement
of Work' and the terms of Crown Castle Purchase Order Number 602709, in accordance with application
206598, revision 1.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
LC7: Existing + Reserved + Proposed Equipment Sufficient Capacity
Note: See Table I and Table II for the proposed and existing/reserved loading, respectively.
This analysis has been performed in accordance with the 2012 International Building Code based upon an ultimate
3 -second gust wind speed of 110 mph converted to a nominal 3 -second gust wind speed of 85 mph per section
1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category
C and Risk Category II were used in this analysis.
We at GPD Group appreciate the opportunity of providing our continuing professional services to you and
Crown Castle. If you have anv auestions or need further assistance on this or any other projects please give us
a call. EXP 01/16/15
Respectfully submitted by:
John N. Kabak, S.E. 12/20/13
Washington #: 50892
520 South Main Street . Suite 2531 . Akron, Ohio 44311 . 330-572-2100. Fax 330-572-2101 . www.GPDGroup.com
Glaus, Pyle, Schomer, Burns & De Haven, Inc. dba Glaus, Pyle, Schomer, Burns & De Haven, PC
Crown Castle USA Inc
80 Ft Monopole Tower Structural Analysis
Project Number 2013777.880338.03, Application 206598, Revision 1
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIA
Table 1 - Proposed Antenna and Cable Information
Table 2 - Existing and Reserved Antenna and Cable Information
Table 3 - Design Antenna and Cable Information
3) ANALYSIS PROCEDURE
Table 4 - Documents Provided
3.1) Analysis Method
3.2) Assumptions
4) ANALYSIS RESULTS
Table 5 - Section Capacity (Summary)
Table 6 - Tower Components vs. Capacity
4.1) Recommendations
5) APPENDIX A
tnxTower Output
6) APPENDIX B
Base Level Drawing
7) APPENDIX C
Additional Calculations
tnxTower Report - version 6.1.3.1
December 20, 2013
CCI BU No 880338
Page 2
Crown Castle USA Inc
80 Ft Monopole Tower Structural Analysis
Project Number 2013777.880338.03, Application 206598, Revision 1
1) INTRODUCTION
December 20, 2013
CCI BU No 880338
Page 3
The existing tapered monopole tower has three major sections connected by slip joints. The tower has 12 sides
and is evenly tapered from a 34.5" outer diameter at the base to a 19.5" outer diameter at the top. The structure
is galvanized and has no tower lighting.
The monopole was originally designed by Valmont Industries, Inc. of Valley, Nebraska in March of 1996. The
tower was originally designed for an 85 mph basic wind speed with 1/2" radial ice in accordance with TIA/EIA-
222-E.
2) ANALYSIS CRITERIA
This analysis has been performed in accordance with the 2012 International Building Code based upon an ultimate
3 -second gust wind speed of 110 mph converted to a nominal 3 -second gust wind speed of 85 mph per section
1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category
C and Risk Category II were used in this analysis.
Per section 2.6.4 of the TIA-222-G standard, ice loading may be ignored for structures located in regions where
the design ice thickness is less than or equal to 0.25 inches (6 mm). Ice loading was not considered in this
analysis.
Seismic loads were determined from hand calculations. It was concluded from these calculations that the wind
Toads control the maximum loading on the structure. The seismic loading case will not control. Refer to Appendix
C for seismic calculations.
Table 1 - Proposed Antenna and Cable Information
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer
Antenna Model
Number
of Feed
Lines
Feed
Line
Size (in)
Note
2
Andrew
HBXX-9014DS-A2M
3
7
KMW
ET-X-WM-18-65-8P
1
I RFS Celwave
APXVRR13-C-A20
r—
3
Samsung
2.5G 8T8R RADAR FILTER
77.0
77.0
[
3
Samsung
2.5GHz RRH-V3
3
1-1/4
1
3
Samsung
OPTIC FIBER JUNCTION
CYLINDER
3
Samsung
POWER JUNCTION
CYLINDER
3
Samsung
RRH-P4
otes•
1) See Appendix B for the proposed coax layout.
tnxTower Report - version 6.1.3.1
Crown Castle USA Inc
80 Ft Monopole Tower Structural Analysis
Project Number 2013777.880338.03, Application 206598, Revision 1
Table 2 - Existing and Reserved Antenna and Cable Information
December 20, 2013
CCI BU No 880338
Page 4
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer
Antenna Model
Number
of Feed
Lines
Feed
Line
Size (in)
Note'
-
PSI Project #: 9704-4120,
dated 05/28/1997
6 Dapa
58010
6
7/8
1
77.0
77.0-
r -
r
I
1 1 F T -Arm Mount [TA 602-3]
T
I
66.0
2
Nokia
FXFB
1
Raycap
RNSDC-7771-PF-48
6
Andrew
ECC1920-VPUB
1
1-1/4
2
61.0
6
Andrew
ETT19V2S12UB
64.0
6
Andrew
TMZXX-6516-A2M
3
Nokia
FRIG
61.0 1
1
T -Arm Mount [TA 602-3]
12
7/8
34.0
34.0
1
Side Arm Mount [SO 701-1]
3
Notes:
1) Equipment to be removed and was not considered in the analysis.
2) Reserved equipment.
3) Empty mount.
Table 3 - Design Antenna and Cable Information
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer
Antenna Model
Number
of Feed
Lines
Feed
Line
Size (in)
97
97
80
80
Swedcom
ALP 9212-N
Platform Mount
ALP 9212-N
1
3) ANALYSIS PROCEDURE
Table 4 - Documents Provided
Platform Mount
Document
Remarks
Reference
Source
Original Tower
Drawings/Specifications
Foundation
Drawings/Specifications
Valmont Order #: 13475-96,
dated 07/23/1996
Valmont Order #: 13505-96,
dated 08/14/1996
Doc ID #: 1954920
Doc ID #: 1954919
T Doc ID #:1581821
Crown DMZ
Crown DMZ
_
I Crown DMZ
Geotechnical Report
PSI Project #: 9704-4120,
dated 05/28/1997
Previous Structural Analysis
GPD Project #: 2012775.880338.02,
dated 12/18/2012
Doc ID #: 3403305 Crown DMZ
3.1) Analysis Method
tnxTower (version 6.1.3.1), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
tnxTower Report - version 6.1.3.1
Crown Castle USA Inc
80 Ft Monopole Tower Structural Analysis
Project Number 2013777.880338.03, Application 206598, Revision 1
3.2) Assumptions
December 20, 2013
CCI BU No 880338
Page 5
1) Tower and structures were built in accordance with the manufacturer's specifications.
2) The tower and structures have been maintained in accordance with the manufacturer's
specification.
3) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
4) When applicable, transmission cables are considered as structural components for calculating
wind Toads as allowed by TIA-222-G.
5) Mount sizes, weights, and manufacturers are best estimates based on site photos provided and
were determined without the benefit of a site visit by GPD.
6) All member connections and foundation steel reinforcing are assumed designed to meet or
exceed the load carrying capacity of the connected member and surrounding soils respectively
unless otherwise specified in this report.
7) All equipment model numbers, quantities, and centerline elevations are as provided in the CCI
CAD package dated 12/06/2013 with any adjustments as noted below.
- There should only be (1) proposed 1-1/4" coax to 61 ft. listed on the base level drawing.
This analysis may be affected if any assumptions are not valid or have been made in error. GPD
Group should be notified to determine the effect on the structural integrity of the tower.
4) ANALYSIS RESULTS
Table 5 - Section Capacity (Summary)
Section
No.
Elevation (ft)
Component
Type
Size
Critical
Element
P (K)
SF*P_allow
(K)
%
Capacity
Pass / Fail
L1
80 - 56
Pole
TP24.3x19.5x0.2188
1 -5.1680
1125.1700
11.6
Pass
L2
56 - 27.4167
Pole
TP29.58x23.0625x0.2813
i
2 -8.4859
1800.8900
24.0
Pass
L3
27.4167 - 0
Pole
TP34.5x28.1007x0.3125
3 T-13.4306
2333.4900
33.0
Pass
T
I
Summary
Pole (L3)
ELC:
33.0 1
Load Case 7
Pass
] Pass
-
T
Rating =
33.0
Table 6 - Tower Component Stresses vs. Capacity — LC7
Notes
Component
Elevation (ft)
% Capacity
Pass / Fail
I Anchor Rods
I Base Plate
T Base Foundation I
0
30.4
17.2
32.1
_I
r
Pass
Pass
Pass
Structure Rating (max from all components) =
33%
Notes:
1) See additional documentation in "Appendix C - Additional Calculations" for calculations supporting the % capacity
consumed.
2) Foundation capacity determined by comparing analysis reactions to original design reactions, considering a factor of
1.35 per TIA-222-G.
4.1) Recommendations
The existing tower and its foundation are sufficient for the proposed loading and do not require
modifications.
tnxTower Report - version 6.1.3.1
6 -own Castle USA Inc
80 Ft Monopole Tower Structural Analysis
Project Number 2013777.880338.03, Application 206598, Revision 1
5) DISCLAIMER OF WARRANTIES
December 20, 2013
CCI BU No 880338
Page 6
GPD GROUP has not performed a site visit to the tower to verify the member sizes or antenna/coax loading. If
the existing conditions are not as represented on the tower elevation contained in this report, we should be
contacted immediately to evaluate the significance of the discrepancy. This is not a condition assessment of the
tower or foundation. This report does not replace a full tower inspection. The tower and foundations are
assumed to have been properly fabricated, erected, maintained, in good condition, twist free, and plumb.
The engineering services rendered by GPD GROUP in connection with this Structural Analysis are limited to a
computer analysis of the tower structure and theoretical capacity of its main structural members. All tower
components have been assumed to only resist dead loads when no other loads are applied. No allowance was
made for any damaged, bent, missing, loose, or rusted members (above and below ground). No allowance was
made for loose bolts or cracked welds.
GPD GROUP does not analyze the fabrication of the structure (including welding). It is not possible to have all
the very detailed information needed to perform a thorough analysis of every structural sub -component and
connection of an existing tower. GPD GROUP provides a limited scope of service in that we cannot verify the
adequacy of every weld, plate connection detail, etc. The purpose of this report is to assess the feasibility of
adding appurtenances usually accompanied by transmission lines to the structure.
It is the owner's responsibility to determine the amount of ice accumulation in excess of the code specified
amount, if any, that should be considered in the structural analysis.
The attached sketches are a schematic representation of the analyzed tower. If any material is fabricated from
these sketches, the contractor shall be responsible for field verifying the existing conditions, proper fit, and
clearance in the field. Any mentions of structural modifications are reasonable estimates and should not be
used as a precise construction document. Precise modification drawings are obtainable from GPD GROUP, but
are beyond the scope of this report.
Miscellaneous items such as antenna mounts, etc., have not been designed or detailed as a part of our work.
We recommend that material of adequate size and strength be purchased from a reputable tower manufacturer.
GPD GROUP makes no warranties, expressed and/or implied, in connection with this report and disclaims any
liability arising from material, fabrication, and erection of this tower. GPD GROUP will not be responsible
whatsoever for, or on account of, consequential or incidental damages sustained by any person, firm, or
organization as a result of any data or conclusions contained in this report. The maximum liability of GPD
GROUP pursuant to this report will be limited to the total fee received for preparation of this report.
tnxTower Report - version 6.1.3.1
Crown Castle USA Inc
80 Ft Monopole Tower Structural Analysis
Project Number 2013777.880338.03, Application 206598, Revision 1
APPENDIX A
TNXTOWER OUTPUT
tnxTower Report - version 6.1.3.1
December 20, 2013
CCI BU No 880338
Page 7
.--
N
32.00 32.58 \ 24.00
N
N
N
c
4.00
19.5000
24.3000
A572-65
3.4 2.6 1.2
77
0.2813
m
a
23.0625
29.5800
T -Arm Mount [TA 602-3]
N
N
id
HBXX-9014DS-A2M w/ Mount Pipe
28.1007
34.5000
Section
Length (ft)
Number of Sides_
Thickness (in)
Socket Length (ft)
0
0
Fa
Bot Dia (in)
Grade
Weight (K) 7.3
80.01t
56.0
27.4 ft
0.00
1
DESIGNED APPURTENANCE LOADING
TYPE
ELEVATION
TYPE
ELEVATION
T -Arm Mount [TA 602-3]
77
(3) Pipe Mount 4'x2.375"
77
APXVRRI3-C-A20 w/ Mount Pipe
77
(3) Pipe Mount 4'x2.375"
77
HBXX-90140S-A2M w/ Mount Pipe
77
T -Arm Mount [TA 602-3]
61
HBXX-9014DS-A2M w/ Mount Pipe
77
(2) TMZXX-6516-A2M w/ Mount Pipe
61
RRH-P4
77
(2) TMZXX-6516-A2M w/ Mount Pipe
61
RRH-P4
77
(2) TMZXX-6516-A2M w/ Mount Pipe
61
RRH-P4
77
(2) ETT19V2S12UB
61
ET-X-WM-18-65-8P w/ Mount Pipe
77
(2) ETT19V2S12UB
61
ET-X-WM-18-65-8P w/ Mount Pipe
77
(2) ETT19V2S12UB
61
ET-X-WM-18-65-8P w/ Mount Pipe
77
(2) ECC1920-VPUB
61
2.5GHz RRH-V3
77
(2) ECC1920-VPUB
61
2.5GHz RRH-V3
77
(2) ECC1920-VPUB
61
2.5GHz RRH-V3
77
FRIG
61
2.5G 8T8R RADAR FILTER
77
FRIG
61
2.5G 8T8R RADAR FILTER
77
FRIG
61
2.5G 8T8R RADAR FILTER
77
FXFB
61
OPTIC FIBER JUNCTION CYLINDER
77
FXFB
61
OPTIC FIBER JUNCTION CYLINDER
77
RNSDC-7771-PF-48
61
OPTIC FIBER JUNCTION CYLINDER
77
Pipe Mount 5'x2.375"
61
POWER JUNCTION CYLINDER
77
Pipe Mount 5'x2.375"
61
POWER JUNCTION CYLINDER
77
Pipe Mount 5'02.375"
61
POWER JUNCTION CYLINDER
77
Side Arm Mount [S0701-1]
34
(3) Pipe Mount 4x2.375"
77
MATERIAL STRENGTH
GRADE
Fy
Fu
GRADE 1 Fy
Fu
A572-65
65 ksi
80 ksi
TOWER DESIGN NOTES
1. Tower is located in King County, Washington.
2. Tower designed for Exposure C to the TIA-222-G Standard.
3. Tower designed for a 85 mph basic wind in accordance with the TIA-222-G Standard.
4. Deflections are based upon a 60 mph wind.
5. Tower Structure Class II.
6. Topographic Category 1 with Crest Height of 0.00 ft
7. TOWER RATING: 33%
ALL REACTIONS
ARE FACTORED
AXIAL
13K
SHEAR MOMENT
10 K 527 kip -ft
TORQUE 0 kip -ft
REACTIONS - 85 mph WIND
GPD Group
520 South Main Street, Suite 2531
GPD GROUP Akron, OH 44311
GPD Group Phone: (330) 572-2222
FAX: (330) 572-3722
job: TUKWILA - BU #: 880338
Project: 2013777.880338.03
Client: Crown Castle USA, Inc.
Drawn by: bkelly
App'd:
Code: TIA-222-G
Date 12/20/13
Scale: NTS
Path: T.\Crawn\880338103\fiN880338.eri
Dwg No E-1
80.00
Round
Face A
Feed Line Distribution Chart
0' - 80'
Flat App In Face App Out Face Truss Leg
77.00
61.00
8.00
Face B
Face C
80.00
77.00
61.00
8.00
(3) TYPE 1(1-1141
56.00
27.42
0.00
GPD Group
/�, 520 South Main Street, Suite 2531
GPD GROUP Akron, OH 44311
GPD Group Phone: (330) 572-2222
FAX: (330) 572-3722
job: TUKWILA - BU #: 880338
Project: 2013777.880338.03
Client: Crown Castle USA, Inc.
Drawn by: bkelly
App'd:
Code' TIA-222-G
Date 12/20/13
Scale: NTS
Path: T:1Crownt880338t010 01880338.0.1
Dwg No. E-7
tnxTower
GPD Group
520 South Main Street, Suite 2531
Akron, OH 44311
Phone: (330)572-2222
FAX: (330) 572-3722
Job
TUKWILA - BU #: 880338
Page
1 of 6
Project
2013777.880338.03
Date
13:56:34 12/20/13
Client
Crown Castle USA, Inc.
Designed by
bkelly
Tower Input Data
There is a pole section.
This tower is designed using the TIA-222-G standard.
The following design criteria apply:
Tower is located in King County, Washington.
Basic wind speed of 85 mph.
Structure Class II.
Exposure Category C.
Topographic Category 1.
Crest Height 0.00 ft.
Deflections calculated using a wind speed of 60 mph.
A non-linear (P -delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs
Consider Moments - Horizontals
Consider Moments - Diagonals
Use Moment Magnification
Use Code Stress Ratios
4 Use Code Safety Factors - Guys
Escalate Ice
Always Use Max Kz
Use Special Wind Profile
Include Bolts In Member Capacity
Leg Bolts Are At Top Of Section
Secondary Horizontal Braces Leg
Use Diamond Inner Bracing (4 Sided)
Add IBC .6D+W Combination
Distribute Leg Loads As Uniform
Assume Legs Pinned
) Assume Rigid Index Plate
▪ Use Clear Spans For Wind Area
Use Clear Spans For KUr
Retension Guys To Initial Tension
Bypass Mast Stability Checks
▪ Use Azimuth Dish Coefficients
J Project Wind Area of Appurt.
Autocalc Torque Arm Areas
SR Members Have Cut Ends
Sort Capacity Reports By Component
Triangulate Diamond Inner Bracing
Use TIA-222-G Tension Splice Capacity
Exemption
Treat Feedline Bundles As Cylinder
Use ASCE 10 X -Brace Ly Rules
Calculate Redundant Bracing Forces
Ignore Redundant Members in FEA
SR Leg Bolts Resist Compression
All Leg Panels Have Same Allowable
Offset Girt At Foundation
Consider Feedline Torque
Include Angle Block Shear Check
Poles
Include Shear -Torsion Interaction
Always Use Sub -Critical Flow
Use Top Mounted Sockets
Tapered Pole Section Geometry
Section Elevation
ft
Section
Length
ft
Splice
Length
ft
Number Top Bottom Wall
of Diameter Diameter Thickness
Sides in in in
Bend
Radius
in
Pole Grade
LI 80.00-56.00 24.00
L2 56.00-27.42 32.58
4.00 12 19.5000 24.3000
4.58 12 23.0625 29.5800
L3 27.42-0.00 32.00 12 28.1007 34.5000
0.2188
0.2813
0.3125
0.8750
1.1250
1.2500
A572-65
(65 ksi)
A572-65
(65 ksi)
A572-65
(65 ksi)
tnxTower
GPD Group
520 South Main Street, Suite 2531
Akron, OH44311
Phone: (330) 572-2222
FAX: (330) 572-3722
Job
TUKWILA - BU #: 880338
g Pa e
2 of 6
Project
2013777.880338.03
Date
13:56:34 12/20/13
Client
Crown Castle USA, Inc.
Designed by
bkelly
Tapered Pole Properties
Section Tip Dia. Area 1
inz in°
in
r
in
in
1/C
in3
J
in°
It/Q
int
w
in
w/t
Ll 20.1879 13.5812 644.4592 6.9027 10.1010 63.8015 1305.8491 6.6843 4.6398 21.21
25.1572 16.9622 1255.5296 8.6211 12.5874 99.7450 2544.0434 8.3483 5.9261 27.091
L2 24.7044 20.6313 1366.6805 8.1557 11.9464 114.4013 2769.2653 10.1541 5.4270 19.296
30.6235 26.5337 2907.2450 10.4890 15.3224 189.7377 5890.8665 13.0591 7.1737 25.506
L3 30.0409 27.9619 2755.9677 9.9482 14.5562 189.3332 5584.3377 13.7620 6.6935 21.419
35.7170 34.4012 5132.0854 12.2391 17.8710 287.1739 10398.9964 16.9312 8.4085 26.907
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description
Sector Component Placement
Type
ft
Total Number Start/End Width or Perimeter Weight
Number Per Row Position Diameter
in in plf
Step Pegs
Safety Line (3/8")
***
C Surface Ar 80.00 - 8.00 1 1 -0.250 0.8000
(CaAa) 0.250
C Surface Ar 80.00 - 8.00 1 1 0.000 0.3750
(CaAa) 0.000
2.72
0.22
Feed Line/Linear Appurtenances - Entered As Area
Description Face Allow Component Placement
or Shield Type
Leg
ft
Total
Number
CAAA
ft2/ft
Weight
plf
LDF5-50A(7/8") A No Inside Pole 61.00 - 8.00 12 No Ice 0.00
ASU9323TYP01( 1-1/4) A No Inside Pole 61.00 - 8.00 1 No Ice 0.00
TYPE 1(1-1/4") C No Inside Pole 77.00 - 8.00 3 No Ice 0.00
***
0.33
1.05
0.50
Discrete Tower Loads
Description
Face Offset Offsets: Azimuth
or Type Horz Adjustment
Leg Lateral
Placement
Vert
ft ft
ft
ft
CAAA
Front
CAAA
Side
ft2 ft'
Weight
K
T -Arm Mount [TA 602-3] C None 0.0000 77.00 No Ice 11.59 11.59 0.7743
APXVRR13-C-A20 w/ A From Leg 4.00 0.0000 77.00 No Ice 7.69 4.03 0.0539
Mount Pipe 0.00
0.00
HBXX-9014DS-A2M w/ B From Leg 4.00 0.0000 77.00 No Ice 6.36 4.71 0.0517
Mount Pipe 0.00
0.00
HBXX-9014DS-A2M w/ C From Leg 4.00 0.0000 77.00 No Ice 6.36 4.71 0.0517
Mount Pipe 0.00
0.00
RRH-P4 A From Leg 4.00 0.0000 77.00 No Ice 3.19 2.07 0.0595
0.00
0.00
RRH-P4 B From Leg 4.00 0.0000 77.00 No Ice 3.19 2.07 0.0595
0.00
0.00
RRH-P4 C From Leg 4.00 0.0000 77.00 No Ice 3.19 2.07 0.0595
0.00
GPD Group
520 South Main Street, Suite 2531
Akron, OH 44311
Phone: (330)572-2222
FAX: (330) 572-3722
Job °b
TUKWILA - BU #: 880338
Page
3 of 6
Project
2013777.880338.03
Date
13:56:34 12/20/13
Client
Crown Castle USA, Inc.
Designed by
bkelly
Description
Face Offset Offsets: Azimuth Placement
or Type Horz Adjustment
Leg Lateral
Vert
ftt
ft
ft
CAAA
Front
CAAA
Side
Weight
K
0.00
ET-X-WM-18-65-8P w/ A From Leg 4.00 0.0000 77.00 No Ice 7.35 4.43 0.0586
Mount Pipe 0.00
0.00
ET-X-WM-18-65-8P w/ B From Leg 4.00 0.0000 77.00 No Ice 7.35 4.43 0.0586
Mount Pipe 0.00
0.00
ET-X-WM-I8-65-8P w/ C From Leg 4.00 0.0000 77.00 No Ice 7.35 4.43 0.0586
Mount Pipe 0.00
0.00
2.5GHz RRH-V3 A From Leg 4.00 0.0000 77.00 No Ice 2.80 1.42 0.0595
0.00
0.00
2.5GHz RRH-V3 B From Leg 4.00 0.0000 77.00 No Ice 2.80 1.42 0.0595
0.00
0.00
2.5GHz RRH-V3 C From Leg 4.00 0.0000 77.00 No Ice 2.80 1.42 0.0595
0.00
0.00
2.5G 8T8R RADAR FILTER A From Leg 4.00 0.0000 77.00 No Ice 0.94 0.35 0.0220
0.00
0.00
2.5G 8T8R RADAR FILTER B From Leg 4.00 0.0000 77.00 No Ice 0.94 0.35 0.0220
0.00
0.00
2.5G 8T8R RADAR FILTER C From Leg 4.00 0.0000 77.00 No Ice 0.94 0.35 0.0220
0.00
0.00
OPTIC FIBER JUNCTION A From Leg 4.00 0.0000 77.00 No Ice 0.45 0.45 0.0020
CYLINDER 0.00
0.00
OPTIC FIBER JUNCTION B From Leg 4.00 0.0000 77.00 No Ice 0.45 0.45 0.0020
CYLINDER 0.00
0.00
OPTIC FIBER JUNCTION C From Leg 4.00 0.0000 77.00 No Ice 0.45 0.45 0.0020
CYLINDER 0.00
0.00
POWER JUNCTION A From Leg 4.00 0.0000 77.00 No Ice 0.43 0.43 0.0033
CYLINDER 0.00
0.00
POWER JUNCTION B From Leg 4.00 0.0000 77.00 No Ice 0.43 0.43 0.0033
CYLINDER 0.00
0.00
POWER JUNCTION C From Leg 4.00 0.0000 77.00 No Ice 0.43 0.43 0.0033
CYLINDER 0.00
0.00
(3) Pipe Mount 4'x2.375" A From Leg 4.00 0.0000 77.00 No Ice 0.87 0.87 0.0185
0.00
0.00
(3) Pipe Mount 4'x2.375" B From Leg 4.00 0.0000 77.00 No Ice 0.87 0.87 0.0185
0.00
0.00
(3) Pipe Mount 4'x2.375" C From Leg 4.00 0.0000 77.00 No Ice 0.87 0.87 0.0185
0.00
0.00
T -Arm Mount [TA 602-3] C None 0.0000 61.00 No Ice 11.59 11.59 0.7743
(2) TMZXX-6516-A2M w/ A From Leg 4.00 0.0000 61.00 No Ice 5.94 4.15 0.0508
Mount Pipe 0.00
tnxTower
GPD Group
520 South Main Street, Suite 2531
Akron, OH44311
Phone: (330) 572-2222
FAX: (330) 572-3722
Job
TUKWILA - BU #: 880338
Page
4 of 6
Project
2013777.880338.03
Date
13:56:34 12/20/13
Client
Crown Castle USA, Inc.
Designed by
bkelly
Description
Face Offset Offsets: Azimuth Placement
or Type Horz Adjustment
Leg Lateral
Vert
ft ft
ft
ft
CAAA CAAA Weight
Front Side
ft2 ft2
K
3.00
(2) TMZXX-6516-A2M w/ B From Leg 4.00 0.0000 61.00 No Ice 5.94 4.15 0.0508
Mount Pipe 0.00
3.00
(2) TMZXX-6516-A2M w/ C From Leg 4.00 0.0000 61.00 No Ice 5.94 4.15 0.0508
Mount Pipe 0.00
3.00
(2) ETT19V2SI2UB A From Leg 4.00 0.0000 61.00 No Ice 0.67 0.32 0.0139
0.00
3.00
(2) ETT19V2S12UB B From Leg 4.00 0.0000 61.00 No Ice 0.67 0.32 0.0139
0.00
3.00
(2) ETT19V2S12UB C From Leg 4.00 0.0000 61.00 No Ice 0.67 0.32 0.0139
0.00
3.00
(2) ECC1920-VPUB A From Leg 4.00 0.0000 61.00 No Ice 0.54 0.21 0.0080
0.00
3.00
(2) ECC1920-VPUB B From Leg 4.00 0.0000 61.00 No Ice 0.54 0.21 0.0080
0.00
3.00
(2) ECC1920-VPUB C From Leg 4.00 0.0000 61.00 No Ice 0.54 0.21 0.0080
0.00
3.00
FRIG A From Leg 4.00 0.0000 61.00 No Ice 2.79 1.10 0.0573
0.00
3.00
FRIG B From Leg 4.00 0.0000 61.00 No Ice 2.79 1.10 0.0573
0.00
3.00
FRIG C From Leg 4.00 0.0000 61.00 No Ice 2.79 1.10 0.0573
0.00
3.00
FXFB A From Leg 4.00 0.0000 61.00 No Ice 0.99 1.12 0.0551
0.00
5.00
FXFB B From Leg 4.00 0.0000 61.00 No Ice 0.99 1.12 0.0551
0.00
5.00
RNSDC-7771-PF-48 A From Leg 4.00 0.0000 61.00 No Ice 3.71 1.38 0.0200
0.00
5.00
Pipe Mount 5'x2.375" A From Leg 4.00 0.0000 61.00 No Ice 1.19 1.19 0.0223
0.00
0.00
Pipe Mount 5'x2.375" B From Leg 4.00 0.0000 61.00 No Ice 1.19 1.19 0.0223
0.00
0.00
Pipe Mount 5'x2.375" C From Leg 4.00 0.0000 61.00 No Ice 1.19 1.19 0.0223
0.00
0.00
Side Arm Mount (SO 701-1) B From Leg 1.00 0.0000 34.00 No Ice 0.85 1.67 0.0650
0.00
0.00
tnxTower
GPD Group
520 South Main Street, Suite 2531
Akron, OH 44311
Phone: (330) 572-2222
FAX: (330) 572-3722
Job
TUKWILA - BU #: 880338
Page
5 of 6
Project
2013777.880338.03
Date
13:56:34 12/20/13
Client
Crown Castle USA, Inc.
Designed by
bkelly
Maximum Tower Deflections - Service Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
Twist
L1
L2
L3
80-56
60 - 27.4167
32-0
4.424
2.711
0.839
26
26
32
0.4191
0.3844
0.2308
0.0004
0.0005
0.0002
Critical Deflections and Radius of Curvature - Service Wind
Elevation
ft
Appurtenance
Gov.
Load
Comb.
Deflection
in
Tilt
Twist
77.00 T -Arm Mount [TA 602-3] 26
61.00 T -Arm Mount [TA 602-3] 26
34.00 Side Arm Mount [SO 701-1] 32
4.161
2.793
0.935
0.4161
0.3875
0.2443
0.0005
0.0005
0.0002
Radius of
Curvature
ft
77383
20155
6741
Maximum Tower Deflections - Design Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
Twist
L1
L2
L3
80-56
60 - 27.4167
32-0
15.917
9.757
3.019
2
2
14
1.5078
1.3827
0.8306
0.0016
0.0018
0.0008
Critical Deflections and Radius of Curvature - Design Wind
Elevation
ft
Appurtenance
Gov.
Load
Comb.
Deflection
in
Tilt
Twist
77.00 T -Arm Mount [TA 602-3]
61.00 T -Arm Mount [TA 602-3]
34.00 Side Arm Mount [SO 701-1]
2
2
14
14.971
10.051
3.366
1.4969
1.3939
0.8795
0.0017
0.0019
0.0009
Radius of
Curvature
ft
21591
5622
1874
Compression Checks
Pole Design Data
Section Elevation
No.
ft
Size
L L Kl/r A
ft ft
P„
it? K
Ratio
Pu
K 4)P.
Ll 80 - 56 (1) TP24.3x19.5x0.2188 24.00 0.00 0.0 16.3987 -5.1680 1125.1700 0.005
L2 56 - 27.4167 TP29.58x23.0625x0.2813 32.58 0.00 0.0 25.7034 -8.4859 1800.8900 0.005
(2)
L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 32.00 0.00 0.0 34.4012 -13.4306 2333.4900 0.006
tnxTower
GPD Group
520 South Main Street, Suite 2531
Akron, OH 44311
Phone: (330) 572-2222
(330) 572-3722
TUKWILA - BU #: 880338
Page
g e
6 of 6
Project
2013777.880338.03
Date
13:56:34 12/20/13
Client
Crown Castle USA, Inc.
Designed by
bkelly
y
Pole Bending Design Data
Section Elevation
No.
ft
Size
M�
�N1„r
Ratio
M„„
kip ft kip ft $M kip ft kip ft
M.
coM„y Ratio
M„,,
LI 80 - 56 (1) TP24.3x19.5x0.2188 59.29 532.89 0.111 0.00 532.89 0.000
L2 56 - 27.4167 TP29.58x23.0625x0.2813 244.19 1039.25 0.235 0.00 1039.25 0.000
(2)
L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 526.50 1623.29 0.324 0.00 1623.29 0.000
Pole Shear Design Data
Section Elevation
No.
ft
Size
Actual
V
K
OV„
K
Ratio Actual
V T
4V kip ft
4T
kip ft
Ratio
T
LI 80 - 56 (1) TP24.3x19.5x0.2188 5.5889 562.5850 0.010 0.14
L2 56 - 27.4167 TP29.58x23.0625x0.2813 7.6971 900.4430 0.009 0.24
(2)
L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 9.9242 1161.0400 0.009 0.24
1080.53
2107.28
OT
0.000
0.000
3291.53 0.000
Pole Interaction Design Data
Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow.
No. P„ M,,r M„, V„ T Stress Stress
ft OP„ OM.. eine. IfpV OT Ratio Ratio
LI 80 - 56 (1) 0.005 0.111 0.000 0.010 0.000 0.116 1.000
L2 56 - 27.4167 0.005 0.235 0.000 0.009 0.000 0.240 1.000
(2) V
L3 27.4167 - 0 (3) 0.006 0.324 0.000 0.009 0.000 0.330 1.000
r
Criteria
4.8.2 V
4.8.2 V
4.8.2 V/
Section Capacity Table
Section
No.
Elevation
ft
Component
Type
Size
Critical P
Element K
OP„n„,,.
Pass
K Capacity Fail
LI 80 - 56 Pole TP24.3x19.5x0.2188 1 -5.1680 1125.1700 11.6 Pass
L2 56 - 27.4167 Pole TP29.58x23.0625x0.2813 2 -8.4859 1800.8900 24.0 Pass
L3 27.4167 - 0 Pole TP34.5x28.1007x0.3125 3 -13.4306 2333.4900 33.0 Pass
Summary ELC: Load Case 7
Pole (L3) 33.0 Pass
Rating = 33.0 Pass
Crown Castle USA Inc
80 Ft Monopole Tower Structural Analysis
Project Number 2013777.880338.03, Application 206598, Revision 1
APPENDIX B
BASE LEVEL DRAWING
tnxTower Report - version 6.1.3.1
December 20, 2013
CCI BU No 880338
Page 8
way 1 ma IWO a1 amain D//nl+t
n mp sd W ass IdDDsa t7V1 t D/WD
caw 1 a10 ru lolano IomIIIw a/II/n
_. 1 mo >o d aanon
1111/IosD led 10M10/11 TMnus
11110/_% No✓1
m mD Eta a1 ®I ID1ato 11Fb dOVW
alai / asD ma W wan mhl/n
M 0011 1 MD IMO — it 0D 1sDs1 10.44//1
Y Man / 111)20 MN a1 alias all .1.1.
a
ga'
go
m�i
opo
W
0.
1
s
9
BASE LEVEL DRAWING
4
Crown Castle USA Inc
80 Ft Monopole Tower Structural Analysis
Project Number 2013777.880338.03, Application 206598, Revision 1
APPENDIX C
ADDITIONAL CALCULATIONS
tnxTower Report - version 6.1.3.1
December 20, 2013
CCI BU No 880338
Page 9
L.
Stiffened or Unstiffened, Ungrouted, Circular Base Plate - Any Rod Material
Assumption: Clear space between bottom of leveling nut and top of concrete not exceeding (1)*(Rod Diameter)
TIA Rev G
Site Data
BU#: 880338
Site Name: TUKWILA
App #: 206598 Rev. 1
Pole Manufacturer:I Other
Anchor Rod Data
Qty:
8
in
Diam:
2.25
in
Rod Material:
A615 -J
ksi
Strength (Fu):
100
ksi
Yield (Fy):
75
ksi
Bolt Circle:
42.22
in
Plate Data
Diam:
48.22
in
Thick:
2.375
in
Grade:
60
ksi
Single -Rod B-eff:
13.87
in
Stiffener Data (Welding at both sides)
Config:
Weld Type:
Groove Depth:
Groove Angle:
Fillet H. Weld:
0
*
in **
degrees
<-- Disregard
in
in
in
in
in
ksi
ksi
Thick:
0.3125
in
Grade:
Fillet V. Weld:
ksi
Width:
Height:
Thick:
Notch:
Grade:
Weld str.:
12
„0„ IF Round
Fu
80
ksi
Reinf. Fillet Weld
Pole Data
Diam:
34.5
in
Thick:
0.3125
in
Grade:
65
ksi
# of Sides:
12
„0„ IF Round
Fu
80
ksi
Reinf. Fillet Weld
0
"0" if None
Reactions
Mu:
527
ft -kips
Axial, Pu:
13
kips
Shear, Vu:
10
kips
Eta Factor, q
0.5
TIA G (Fig. 4-4)
If No stiffeners, Criteria: AISC LRFD
Anchor Rod Results
Max Rod (Cu+ Vu/q):
Allowable Axial, *Fu*Anet:
Anchor Rod Stress Ratio:
Base Plate Results
Base Plate Stress:
Allowable Plate Stress:
Base Plate Stress Ratio:
<-Only Applcable to Unstiffened Cases
79.0 Kips
260.0 Kips
30.4% Pass
Flexural Check
9.3 ksi
54.0 ksi
17.2% Pass
n/a
Stiffener Results
Horizontal Weld : n/a
Vertical Weld: n/a
Plate Flex+Shear, fb/Fb+(fv/Fv)^2: n/a
Plate Tension+Shear, ft/Ft+(fv/Fv)^2 n/a
Plate Comp. (AISC Bracket): n/a
Pole Results
Pole Punching Shear Check: n/a
0
0 0
* 0 = none, 1 = every bolt, 2 = every 2 bolts, 3 = 2 per bolt
'* Note: for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes
Rigid
AISC LRFD
cp*Tn
Rigid
AISC LRFD
cp*Fy
Y.L. Length:
24.34
CCIplate 1.5 - Circular Base G 1.3, Effective March 19, 2012 Analysis Date: 12/20/2013
FOUNDATION REACTION COMPARISON
BU #: 880338
WO#: 686043
REACTIONS
DESIGN
REACTIONS
CURRENT
REACTIONS
% CAPACITY
MOMENT (ft -kips)
1643.5
527
32.1
Notes:
1) Design reactions from CCIsites - Doc ID #: 1954920
2) Design reactions considering a factor of 1.35 per Section 15.5 of TIA-222-G.
Seismic Calculations (TIA-222-G)
Analysis Method: Equivalent Modal Analysis, Method 2 (Section 2.7.8, TIA-222-G)
GPD Job Number 2013777.880338.03
Site Name TUKWILA
Site Number 880338
City Tukwila
State Washington
County King
Tower Type Monopole
Base OD 34.5 in
Base Thickness 0.3125 in
# of Sides 12
Structure Height (ft) 80
Top OD
Top Thickness
Structure Classification 11 (Table 2-1, TIA-222-G)
Importance Factor (I) 1 (Table 2-3, TIA-222-G)
S1 0.562 (USGS, 2012 IBC)
Ss 1.499 (USGs, 2012 IBC)
Site Classification D (Table 2-11, TIA-222-G)
Fa 1.000 (Table 2-12, TIA-222-G, interpolation allowed)
Fv 1.500 (Table 2-13, TIA-222-G, interpolation allowed)
$Dg 0.999 (Eq. 2.7.6, TIA-222-G)
SD1 0.562 (Eq. 2.7.6, TIA-222-6)
Wt 11.058 (Kips)
Wu 2.980 (Kips)
WL 8.078 (Kips)
g 386.1 (in's�)
I,� 2892.34 (in)
E 29000.00 (ksi)
f1
R
SA
Earthquake LRFD Load Factor
Discrete Appurtenances
Appurtenances @ 77'
Appurtenances @ 61'
Appurtenances @ 34'
Linear Appurtenances
Coax from 56' - 80'
Coax from 27.42' - 56'
Coax from 0' - 27.42'
Structure Components
Tower Section from 56' - 80'
Tower Section from 27' - 56'
Tower Section from 0' - 27'
Totals
0.754 (Eq. 2.7.11, TIA-222-G)
1.5 (2.7.8.1, TIA-222-G)
0.424 (2.7.8.1, TIA-222-G)
1 (2.3.2, TIA-222-G)
w ki s
19.5 in
0.21875 in
Service Level
S„ F� Seismic Forces
1.520
1.460
0.060
77
61
34
1.581
0.210
0.222
1.6016
0.2046
0.0089
1.602 kips
0.205 kips
0.009 kips
0.187
0.342
0.232
68
41.71
13.71
0.615
0.165
0.173
0.0767
0.0375
0.0267
0.077 kips
0.037 kips
0.027 kips
1.247
2.615
81 3.395
11.05
68
41.71
13.71
0.615
0.165
0.173
0.5114
0.2868
0.3912
0.511 kips
0.287 kips
0.391 kips
"The service level seismic forces in the table above were input into a supplemental tnxTower
analysis as "user defined loads". The resulting tower stress capacity ratings are in the table below**
3.15 315 kips
Tower Stress Capacity Comparison
Structure Components
Capacity Considering Seismic Loading
Capacity Considering Wind Loading
Controlling
Tower Section from 56' - 80'
Tower Section from 27.42' - 56'
Tower Section from 0' - 27.42'
6.6% 11.6% Wind
10.5% 24.0% Wind
12.8% 33.0% Wind
Overall Controlling Load:' sx Wind
Overall Capacity:, 33.0
NUl
7
ONg
N
/
/
1 . i
N
�
r
N
O
4.00
v
19.5000
24.3000
V9
N
a
rD
(V
M
68
a7
N
O
O
N
v
23.0625
29.5800
N
O
Appurtenances @ 61'
28.1007
34.5000
a
r
O
J
Number of Sides
Thickness (in)
Socket Length (11)
-
6
H
O
O
m
D
C7
Weight (K) 7.3
80.0 ft
56.0 ft
27.4 ft
0.00
O
ALL REACTIONS
ARE FACTORED
AXIAL
13K
SHEAR MOMENT
3 K I J 198 kip -ft
REACTIONS - 1 mph WIND
DESIGNED APPURTENANCE LOADING
TYPE
ELEVATION
TYPE
ELEVATION
Appurtenances @ 77'
77
Tower Section from 27' - 56'
41.71
Coax from 56' - 80'
68
Appurtenances @ 34'
34
Tower Section from 56' - 80'
68
Coax from 0' - 27.42'
13.71
Appurtenances @ 61'
61
Tower Section from 0' - 27'
13.71
Coax from 27.42' - 56'
41.71
MATERIAL STRENGTH
GRADE
Fy
Fu
GRADE 1 Fy
Fu
A572-65
65 ksi
80 ksi
TOWER DESIGN NOTES
1. Tower is located in King County, Washington.
2. Tower designed for Exposure C to the TIA-222-G Standard.
3. Tower designed for a 1 mph basic wind in accordance with the TIA-222-G Standard.
4. Tower Structure Class II.
5. Topographic Category 1 with Crest Height of 0.00 ft
6. TOWER RATING: 12.8%
GPD Group
/�, 520 South Main Street, Suite 2531
GPD GROUP Akron, OH 44311
GPD Group Phone: (330) 572-2222
FAX: (330) 572-3722
job: TUKWILA - BU #: 880338
Project: 2013777.880338.03
Client: Crown Castle USA, Inc.
Drawn by: bkelly
App'd:
Code: TIA-222-G
Date: 12/20/13
Scale: NTS
Path: T:\Crown\880338\03\tnx\880338 seismic eri
Dwg No. E-1
NbMIND
tnxTower
GPD Group
520 South Main Street, Suite 2531
Akron, OH 44311
Phone: (330) 572-2222
FAX: (330) 572-3722
Job
TUKWILA - BU #: 880338
g Pa e
1 of 3
Project
2013777.880338.03
Date
14:29:44 12/20/13
Client
Crown Castle USA, Inc.
Designed by
bkelly
Tower Input Data
There is a pole section.
This tower is designed using the TIA-222-G standard.
The following design criteria apply:
Tower is located in King County, Washington.
A non-linear (P -delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs
Consider Moments - Horizontals
Consider Moments - Diagonals
Use Moment Magnification
) Use Code Stress Ratios
4 Use Code Safety Factors - Guys
Escalate Ice
Always Use Max Kz
Use Special Wind Profile
Include Bolts In Member Capacity
Leg Bolts Are At Top Of Section
Secondary Horizontal Braces Leg
Use Diamond Inner Bracing (4 Sided)
Add IBC .6D+W Combination
Distribute Leg Loads As Uniform
Assume Legs Pinned
J Assume Rigid Index Plate
4 Use Clear Spans For Wind Area
Use Clear Spans For KUr
Retension Guys To Initial Tension
Bypass Mast Stability Checks
i Use Azimuth Dish Coefficients
Ai Project Wind Area of Appurt.
Autocalc Torque Arm Areas
SR Members Have Cut Ends
Sort Capacity Reports By Component
Triangulate Diamond Inner Bracing
Use TIA-222-G Tension Splice Capacity
Exemption
Treat Feedline Bundles As Cylinder
Use ASCE 10 X -Brace Ly Rules
Calculate Redundant Bracing Forces
Ignore Redundant Members in FEA
SR Leg Bolts Resist Compression
All Leg Panels Have Same Allowable
Offset Girt At Foundation
Consider Feedline Torque
Include Angle Block Shear Check
Poles
Ai Include Shear -Torsion Interaction
Always Use Sub -Critical Flow
Use Top Mounted Sockets
User Defined Loads
Description
Elevation
ft
Offset Azimuth
From Angle
Centroid
ft
Weight F
F, Seismic CAAc
Force
K K K
K
ft2
Appurtenances @ 77'
Appurtenances @ 61'
Appurtenances @ 34'
Coax from 56' - 80'
Coax from 27.42' - 56'
Coax from 0' - 27.42'
***
Tower Section from 56' - 80'
Tower Section from 27' - 56'
Tower Section from 0' - 27'
***
77.00
61.00
34.00
68.00
41.71
13.71
68.00
41.71
13.71
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
No Ice
No Ice
No Ice
No Ice
No Ice
No Ice
No Ice
No Ice
No Ice
1.5200
1.4600
0.0600
0.1871
0.3416
0.2320
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
1.0010
0.1279
0.0055
0.0480
0.0234
0.0167
0.3197
0.1793
0.2445
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
4._$
...,
tnxTower
GPD Group
520 South Main Street, Suite 2531
Akron, OH44311
Phone: (330) 572-2222
FAX: (330) 572-3722
Job
TUKWILA - BU #: 880338
Page
2 of 3
Project
2013777.880338.03
Date
14:29:44 12/20/13
Client
Crown Castle USA, Inc.
Designed by
bkelly
Maximum Tower Deflections - Seismic
Section
No.
Elevation
ft
Horz. Gov.
Deflection Load
in Comb.
Tilt
Twist
LI
L2
L3
80 - 56
60 - 27.4167
32-0
6.603
3.940
1.174
8
8
8
0.6577
0.5834
0.3287
0.0000
0.0000
0.0000
Critical Deflections and Radius of Curvature - Seismic
Elevation
ft
Appurtenance
Gov.
Load
Comb.
Deflection
in
Tilt
Twist
Radius of
Curvature
ft
77.00
68.00
61.00
41.71
34.00
13.71
Appurtenances @ 77'
Coax from 56' - 80'
Appurtenances @ 61'
Coax from 27.42' - 56'
Appurtenances @ 34'
Coax from 0' - 27.42'
8
8
8
8
8
4
6.191
4.971
4.065
1.944
1.313
0.336
0.6499
0.6219
0.5893
0.4296
0.3497
0.1395
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
35958
14982
9509
5248
4506
10032
Compression Checks
Pole Design Data
Section Elevation
No.
ft
Size
L L Kl/r A
ft ft
P„
in2 K
OP„
K
Ratio
P.
4P„
Ll 80 - 56 (1) TP24.3x19.5x0.2188 24.00 0.00 0.0 16.3987 -4.9999 1125.1700 0.004
L2 56 - 27.4167 TP29.58x23.0625x0.2813 32.58 0.00 0.0 25.7034 -8.4117 1800.8900 0.005
(2)
L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 32.00 0.00 0.0 34.4012 -13.2691 2333.4900 0.006
Pole Bending Design Data
Section Elevation
No.
ft
Size
At,
kip ft kip ft
Ratio
M�
$N1,�
M„,
kip ft kip ft
Ratio
M
(PM„„
LI 80 - 56 (1) TP24.3x19.5x0.2188 32.65 532.89 0.061 0.00 532.89 0.000
L2 56 - 27.4167 TP29.58x23.0625x0.2813 104.37 1039.25 0.100 0.00 1039.25 0.000
(2)
L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 198.41 1623.29 0.122 0.00 1623.29 0.000
4,4
tnxTower
GPD Group
520 South Main Street, Suite 2531
Akron, OH44311
Phone: (330) 572-2222
(330) 572-3722
Job
TUKWILA - BU #: 880338
Page
9
3 of 3
Project
2013777.880338.03
Date
14:29:44 12/20/13
Client
Crown Castle USA, Inc.
Designed by
bkelly
y
Pole Shear Design Data
Section Elevation
No.
ft
Size
Actual
Vu
K
$V
K
Ratio Actual
VT„
qV kip ft
kip ft
Ratio
T
LI 80 - 56 (1) TP24.3x19.5x0.2188 2.4460 562.5850 0.004 0.00 1080.53
L2 56 - 27.4167 TP29.58x23.0625x0.2813 2.7775 900.4430 0.003 0.00 2107.28
(2)
L3 27.4167 - 0 (3) TP34.5x28.1007x0.3125 3.1483 1166.7400 0.003 0.00 3291.53 0.000
4T
0.000
0.000
Pole Interaction Design Data
Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow.
No. P M, , M„. V„ T Stress Stress
ft OP„ 01C $M„,. (1)11„ T Ratio Ratio
Criteria
LI 80 - 56 (1) 0.004 0.061 0.000 0.004 0.000 0-.0666 1.000
1
L2 56 - 27.4167 0.005 0.100 0.000 0.003 0.000 0.105 1.000
(2) Vi
L3 27.4167 - 0 (3) 0.006 0.122 0.000 0.003 0.000 0.128 1.000
4.8.2 V/
4.8.2 .✓ Y
4.8.2 '
Section Capacity Table
Section
No.
Elevation
ft
Component
Type
Size
Critical P
Element K
4P„uo»
K
% Pass
Capacity Fail
LI 80 - 56 Pole TP24.3x19.5x0.2188 1 -4.9999 1125.1700 6.6 Pass
L2 56 - 27.4167 Pole TP29.58x23.0625x0.2813 2 -8.4117 1800.8900 10.5 Pass
L3 27.4167 - 0 Pole TP34.5x28.1007x0.3125 3 -13.2691 2333.4900 12.8 Pass
Summary
Pole (L3) 12.8 Pass
RATING = 12.8 Pass
0400
TO:
City of Tukwila
Department of Community Development
File Number
IL14-0018
LAND USE PERMIT ROUTING FORM
Building
Planning ❑ Public Works 101 Fire Dept.
IDI
Police Dept. 10 Parks/Rec
Project: Sprint 2.5 Wireless Facility
Address: 12200 51st PI. S
Date
transmitted: 3/11/2014
Response
requested by: 3/25/2014
Staff
coordinator: Max Baker
Date response
received:
REVIEWERS: Please specify how the attached plans conflict with your ADOPTED
development regulations, including citations. Be specific in describing the types of changes you
want made to the plans. When referencing codes, please identify the actual requirement and
plan change needed.
The Planning Division review does not supplant each department's ability to administer its own
regulations and permits. However, project consistency at the Plannung review stage is
important to minimize significant later design changes. More than minimal design changes
require further Planning Commission review, even if alteration is required to satisfy a City
requirement. This further review is typically a minimum 60 -day process.
Requirements based on SEPA (e.g., not required by an adopted development regulation)
MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the
method used to calculate the mitigation required. Calculations of project impacts and the
mitigation required (e.g., water capacity, road level of service analyses, or turning analyses)
may be required of the applicant.
COMMENTS
(Attach additional comment sheets and/or support materials as needed.)
Plan check date:
Comments
prepared b
Update date:
0400
City of Tukwila
Department of Community Development
RECEIVED
MAR 112014
TUKWILA
PUBLIC WORKS
File Number
L14-0018
LAND USE PERMIT ROUTING FORM
TO: IDS Building Planning Public Works
Fire Dept.
0
Police Dept.
Parks/Rec
Project: Sprint 2.5 Wireless Facility
Address: 12200 51st PI. S
Date
transmitted: 3/11/2014
Response
requested by: 3/25/2014
Staff
coordinator: Max Baker
Date response
received:
REVIEWERS: Please specify how the attached plans conflict with your ADOPTED
development regulations, including citations. Be specific in describing the types of changes you
want made to the plans. When referencing codes, please identify the actual requirement and
plan change needed.
The Planning Division review does not supplant each department's ability to administer its own
regulations and permits. However, project consistency at the Planning review stage is
important to minimize significant later design changes. More than minimal design changes
require further Planning Commission review, even if alteration is required to satisfy a City
requirement. This further review is typically a minimum 60 -day process.
Requirements based on SEPA (e.g., not required by an adopted development regulation)
MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the
method used to calculate the mitigation required. Calculations of project impacts and the
mitigation required (e.g., water capacity, road level of service analyses, or turning analyses)
may be required of the applicant.
COMMENTS
(Attach additional comment sheets and/or support materials as needed.)
P() hQs no ce2v1 vv1 e45
Plan check date:.
03/12/14
Comments /
prepared by: JO�14JtVQ.,
Update date:
STATE OF TEXAS
COUNTY OF TARRANT
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-3670 FAX: (206) 431-3665
E-mail: planning(a.,TukwilaWA.gov
AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS
PERMISSION TO ENTER PROPERTY
ss
The undersigned being duly sworn and upon oath states as follows: _
BNSF Railway Company is j f'
1. the current owner of the property which is the subject of this application. "14.""I
2. All statements contained in the applications have been prepared by me or my agents and '"e true and correct to the best of my
knowledge.
3. The application is beim submitted with my knowledge and consent.
has authorized Lessee, Sprint Spectrum, through Crown Castle USA to
4. Owner�granV the City, its employees, agents, engineers, contractors or other representatives the right to enter upon Owner's real
property, located at 12200 51' PL S, Tukwila, WA 98178 for the purpose of application."'"
review, for the limited time necessary to complete that purpose.
E!VED
MAR 10 2014
EDEVLLU1'MENT
J�-
5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the
City's entry upon the property, unless the loss or damage is the result of theeaiir negligence of the City.
6. Non -responsiveness to a City intbrmation request for ninety (90) or more days, shall be cause to cancel the application(s) without
refund of fees. � J_
EXECUTED at /'D (f (� Jk P i///n (city), 5C (state), on Se�07I•vh bee- 2 S , 20 / Z
Dennis Auge — Director, BNSF Railway Company
I
(i
is
(Print Name)
2400 Western Center Blvd, Ft Worth, TX 76131
(Address)
(817) 352-0206
On this day personally appeared before me Dennis Auge to me known to be the individual who
executed the foregoing instrument and acknowledged that he/she signed the same as bislher voluntary act and deed for the uses and
purposes mentioned therein. // --
SUBSCRIBED AND SWORN TO BEFORE ME ON THIS Z. DAY OF — 2�11-er, , 20 %Z
47rof of/My Comm. Exp. 05114/2014
DALEN E WINTERMUTE
Notary Public
STATE OF TEXAS
NOTAR ' UBLIC in and for the State of iiirsoloingte+ Texas
residing at 7 Lakeview Dr., Trophy Club, TX 76262
My Commission expires on 05/14/2014
H:\Land Use Applications in PDF\Wneless Communication Facility-Jan26l1.doc
COMPLETE APPLICATION CHECKI,1ST
The materials listed below must be submitted with your application unless specifically waived in writing the Department of
Community Development. Please contact each Department if you feel that certain items are not applicable to your project
and should be waived. Application review will not begin until it is determined to be complete. ADDITIONAL
MATERIALS MAY BE REQUIRED.
The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require
additional information as needed to establish consistency with development standards.
City staff are available to answer questions about application materials at 206-431-3670 (Department of Community
Development) and 206-433-0179 (Department of Public Works).
ti t'�ri t
'moi, el 1101 ,$f.
5( Iltll1c.�1 1.. r'},SL
4:41;z,,, 1�
' F� >4{'Zrfi kA
�if '4 'rt Z
v'. I4 ��V IIn ;i
T�iw
i.. a '.ai i) Tj
I 1 �* ,,,/' 11' I�i!. �i5'Ii F'��
3�F S
�i�j'�f i!Ge[..
�, r ` s '41
� -rtiTy ��,+G�.^ '.�
l.' x°P` F' _' c.
YtA �%r '.w ."'} �J
.1�'x, ... tl�dt r•.. '�&', h...
r -aq �' ..'• �: x ;ii �J$j3Jjr t . {p ._ },,(l �,.
�, tl,SyH' ,P}}y .: "a )N * S' ? y• tl H �; -1 �^ `,{{j����q p'S �. rFi�lF 9�f'l'�ia�`.
A�. 1 }�R 1i r f tl A / f �4Fk `! !� ''Y� ,NM1'¢}t
�'Cq [1. "�^j'.jgt ��'•'i ?. ry r'y- t�(.Y�y�N t4 th$ , F.l
� s1`� ji 3ti .•�i Yi 4 J t 11s»y., ?,,C, aY' {7 ' �3")) c'I s' .�s
-T • }
F$1 !V'}" A 1 - of1}�j.F% •. �..'
�R`h ! � �. M "4 �1..J �".1 "Q i I,jL .i
i ns..�,'�.9t''4^. r. .' i... .t a.,: .. .#:-_s"•>. c> . .!.Fa... s� �: .., .::1':S
. ..di
APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities.
---
le""'
1. Application Checklist (I copy) indicating items submitted with application.
2. Completed Application Form and drawings (5 copies).
17
3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site
map, architectural elevations, method of attachment, proposed screening, location of proposed antennas,
and all other information which accurately depicts the proposed project. Minimum size
is 8 1/2" x 11". Plans shall be no greater than 24" x 36".
✓
4. Application Fee: See Land Use Fee Schedule.
c/
5. Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property
(1 copy attached).
✓
/
6. SEPA Environmental Checklist. SEPA is not required when the facility:
i) Is a microcell and is to be attached to an exiting structure that is not a residence or school and
does not contain a residence or a school;
ii Includes personal wireless antennas, other than a microcell, and is to be attached to an existing
structure (that may be an existing tower) that is not a residence or school and does not contain a
residence or school, and the existing structure to which it is to be attached is located in a
commercial, industrial, manufacturing, forest or agriculture zone; or
iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a
commercial, industrial, manufacturing, forest, or agricultural zone.
�//
7. A letter from the applicant describing the proposed project and describing compliance with the
City's Code requirements.
8. Sensitive Area studies and proposed mitigation (if required).
9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating
compliance with TMC Chapter 8.22, "Noise".
If the application requires a Type 2 review these additional items are needed:
10. Four sets of photo simulations that depict the existing and proposed view of the proposed facility;
11. Materials board for the screening material;
12. Landscaping plan;
13. Letter from a radio frequency engineer that demonstrates that the facility meets Federal
requirements for allowed emissions;
14. If the facility is located within a residential zone, a report from a radio frequency engineer
explaining the need for the proposed wireless communication facility at that location. Additionally, the
applicant shall provide detailed discussion on why the wireless communication facility cannot be
located within a commercial or industrial zone.
HA -and Use Applications in PDF \W reless Communication Facility-Jan2Ol I.doc
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-3670 FAX: (206) 431-3665
E-mail: planning@a,TukwilaWA.gov
WIRELESS TELE-
COMMUNICATION
FACILITIES
INFORMATION
City of Tukwila governs the placement of wireless telecommunication facilities under Tukwila Municipal Code (TMC)
18.58. The review process for new antennas and facilities is based on the type of facility and the location of the facility.
The City's goal is to streamline the placement of desirable facilities that are located on existing cell towers, within
commercial and industrial zones, and on electrical transmission towers.
TABLE A
Type of Permit Required, Based on
Type of Wireless Communication Facility
Zoning')
Type of Facility
Residential
Commercial
Industrial
Transmission tower co -location
Type 1
Type 1
Type 1
Adding antennas to an existing tower
Type 1(2)
Type 1(2)
Typ 1(2)
Utility pole co -location
Type 2
Type 2
Type 2
Concealed building attached
Type 2(3)
Type 2(3)
Type 1
Non -concealed building attached
Type 2
Type 2
Type 1
New tower or waiver request
Type 3
Type 3
Type 3
(1)
(2)
(3)
Zoning for any private/public property or right-of-way:
Residential — LDR, MDR, or HDR.
Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS.
Industrial — LI, HI, MIC/L, or MIC/H.
Provided the height of the tower does not increase and the square footage of the enclosure
area does not increase.
An applicant may request to install a non -concealed building attached facility, under TMC
Section 18.58.150.
H:\Land Use Applications in PDF\Wireless Communication Facility-Jan20 1 1.doc
RECEIVED
CITY OF TUKWILA MAR 10 2014
�n,,,�„, WIRELESS TELE -
Department of Community Developnl,jMI` 6300 Southcenter Boulevard, Tukwila, WA `COMMUNICATION
Telephone: (206) 431-3670 FAX: (206) 431-3665 FACILITIES
E-mail:: planning@TukwilaWA.gov
APPLICATION
FOR STAFF USE ONLY Permits Plus Type: P -WIRE
Planner:
File Number: 1.—`kA' l)
Application Complete Date:
Project File Number:1 LI 14,.0 [6
Application Incomplete Date:
Other File Numbers:
NAME OF PROJECT/DEVELOPMENT: "P'0-0,-17--2. 5 TOL- VO ILA- S g -O3 Xc..4Og
LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and
subdivision, access street, and nearest intersection.
LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement).
000300 - 00o3
DEVELOPMENT COORDINATOR :
The individual who:
• has decision making authority on behalf of the owner/applicant in meetings with City staff,
• has full responsibility for identifying and satisfying all relevant and sometimes overlapping development
standards, and
• is the primary contact with the City, to whom all notices and reports will be sent.
Name: RoNAtS)
Address: tikitnotik iS4 TV- AV Nis- R-�DrvtmN� (N4
Phone: 4Zr^ 202.— 2?b3 FAX:
cri3Os
E-mail: 9.0,JrR,l i eXtt Q (:12-0w&JSTV . CO M
Signature:
H:\Land Use Applications in PDF\Wireless Communication Facility-Jan2011.doc
Date: 3 - 6 - ZOIkt
At all new services & grounding trenches,
provide "WARNING" tape at 12" below grade.
DIG ALERT
"CALL BEFORE YOU DIG"
1-800-424-5555
UTILITY NOTIFICATION CENTER OF WASHINGTON
RECEIVED
MAR 10 2014
(tet )iJn n` L a 1 Y
oEVELOt'M NT
Spri ntc
WASHINGTON STATE CODE COMPLIANCE:
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN
ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS
ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS
TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES.
• 2012 IBC, STANDARDS AND AMENDMENTS -WAC 51-50;
• 2012 IMC, STANDARDS AND AMENDMENTS -WAC 51-52;
• 2012 IFC, STANDARDS AND AMENDMENTS -WAC 51-54;
• 2012 IPC, STANDARDS AND AMENDMENTS -WAC 51-56; 51-57
ACCESSIBILITY REQUIREMENTS:
FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED
ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2009
IBC BUILDING CODE.
CODE BLOCK
♦
SPRINT PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS
FACIIJTY
• INSTALL (3) NEW ANTENNAS (1 PER SECTOR)
• INSTALL (3) RRH UNITS (1 PER SECTOR)
• INSTALL 6 JUNCTION CYLINDERS (2 PER SECTOR)
• INSTALL 3 FILTERS
PROJECT DESCRIPTION
APPROVAL
SIGNATURE
•
DATE
CCIA(?9Y1&"
T-1
SITE ACQUISITION
MANAGER
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
N-1
CONSTRUCTION
MANAGER
REVISIONS
A-1
A&E MANAGER
DESCRIPTION
A-2
PLANNING
CONSULTANT
01/30/14
A-3
RF MANAGER
0
A-4
RF ENGINEER
AF
A-5
PROPERTY
OWNER
A-6
SPRINT
REPRESENTATIVE
A-7
AAV MANAGER
RF -1
SIGNATURE BLOCK
THIS IS AN EXISTING SPRINT WIRELESS TELECOMMUNICATION FACILITY EQUIPMENT UPGRADE
2.5 LAUNCH
TUKWILA
SE03XC408 / CROWN 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
LATITUDE: 47.493744/ 47° 29' 37.4778" (NAD 83) (GOOGLE EARTH)
LONGITUDE: -122.270610/ -122° 16' 14.196" (NAD 83) (GOOGLE EARTH)
MONOPOLE
•
A
AREA MAP
VICINITY MAP
DEPART FROM SPRINT OFFICE (BELLEVUE, WA):
1. HEAD SOUTH ON 124TH AVE NE TOWARD NE 10TH PL
2. TAKE THE 2ND RIGHT ONTO NE 8TH ST
3. SLIGHT RIGHT ONTO THE 1-405 S RAMP
4. KEEP LEFT AT THE FORK AND MERGE ONTO 1-405 S
5. TAKE EXIT 5 TOWARD WASHINGTON 900 E/PARK AVENUE NORTH
6. KEEP RIGHT AT THE FORK, FOLLOW SIGNS FOR PARK AVENUE N
7. CONTINUE ONTO LOGAN AVE N
8. SLIGHT RIGHT ONTO AIRPORT WAY
9. TURN LEFT ONTO RAINIER AVE S
10. TURN RIGHT ONTO SW SUNSET BLVD
11. CONTINUE ONTO MARTIN LUTHER KING WAY S
12. TURN LEFT ONTO S 129TH ST
13. CONTINUE ONTO 50TH PL S
14. TURN RIGHT TOWARD 5 124TH ST
15. TURN RIGHT ONTO S 124TH ST
16. TURN LEFT ONTO 51ST PL S
DESTINATION WILL BE ON THE RIGHT
0.1 M
0.7 M
0.2 M
8.1 M
0.2 M
0.3 M
1.1 M
0.4 M
0.3 M
1.4 M
0.7 M
0.5 M
0.2 M
102 FT
203 FT
184 FT
DRIVING DIRECTIONS
•
SEA 1 1 LE MARKET
SHEET
DESCRIPTION
CCIA(?9Y1&"
T-1
TITLE SHEET
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
N-1
GENERAL NOTES
REVISIONS
A-1
SITE PLAN & ENLARGED SITE PLAN
DESCRIPTION
A-2
COMPOUND PLAN
01/30/14
A-3
EQUIPMENT PLAN
0
A-4
ANTENNA PLANS & SCHEDULES
AF
A-5
EXISTING & PROPOSED SOUTHEAST ELEVATION
A-6
"EXISTING & PROPOSED SOUTHWEST ELEVATION
A-7
EQUIPMENT DETAILS
RF -1
ANTENNA AND CABLE COLOR CODING DETAILS
E-1
SCHEMATIC GROUNDING PLAN
E-2
GROUNDING DETAILS
E-3
GROUNDING DETAILS
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
2-18 1i_
REN. 02-18-15 4.0003
owl
SHEET TITLE
TITLE SHEET__
SHEETNUMBER:REVISION:
T-1
0
SE03XC408
SHEET INDEX
,
I
♦
APPLICANT:
SPRINT SPECTRUM LLC
1000 124TH AVE NE, SUITE 201
BELLEVUE, WA 98005
CONTACT: KEVIN FOY
PH: (206) 427-5856
EMAIL: KEVIN.FOYOSPRINT.COM
PROPERTY INFORMATION;
PROPERTY OWNER: BNSF RAILWAY COMPANY
ADDRESS: 2400 WESTERN CENTER BLVD
FORT WORTH, TX 76131
TOWER OWNER: CROWN CASTLE USA
SITE ID: 880338
ZONING CLASSIFICATION: C
CONSTRUCTION TYPE: IIB
OCCUPANCY: U
JURISDICTION: CIN OF TUKWILA
CURRENT USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY
NEW USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY
PARCEL NUMBER(S):
0003800003
LEASE AREA:
54'-O'
♦
PROJECT SUMMARY
•
ARCHITECT:
THOMAS R. HOLLAND, AIA
PACIFIC TELECOM SERVICES, LLC
506 2ND AVE, SUITE 210
SEATTLE, WA 98104
CONTACT: AMANDA MARTIN
PH: (206) 342-6396
EMAIL AMARTINOPTSWA.COM
STRUCTURAL ENGINEER:
B+T GROUP
1717 S BOULDER, SUITE 300
TULSA, OK 74119
CONTACT: VENU AMBATI
PH: (918) 587-4630
EMAIL: BIWOOBTGRP.COM
PROJECT MANAGER:
CROWN CASTLE USA
8432 154TH AVE NE, BLDG C
REDMOND, WA 98052
CONTACT: TOM GOODE
PH: (425) 202-0191
EMAIL TOM.GOODEOCROWNCASTLE.COM
CONSTRUCTION MANAGER:
CROWN CASTLE USA
8432 154TH AVE NE, BLDG C
REDMOND, WA 98052
CONTACT: LEE BASSETT
PH: (206) 852-0443
ZONING & PERMITTING:
CROWN CASTLE USA
8432 154TH AVE NE, BLDG C
REDMOND, WA 98052
CONTACT: KEVIN CHANG
PH: (425) 202-2763
EMAIL: KEVIN.CHANGOCROWNCASTLE.COM
ELECTRICAL COMPANY:
PUGET SOUND ENERGY
CONTACT: TIM GASSER
PH: 206-947-0335
TELCO COMPANY:
CENTURYUNK
8502 SOUTH STEELE ST
TACOMA, WA 98409
RF ENGINEER:
TBD
Clq -06/ r
•
PROJECT TEAM
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint>
CCIA(?9Y1&"
-rte
�AtIf IC TE L[COY SE9VIC E3. LLC
506 2N0 AYE, SUITE 210
SEATTLE. WA 96104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
ISSUE DATE 02-26-14
ISSUED FOR:CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INITIALS
A
01/30/14
ISSUED FOR 908 CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 1008 CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
2-18 1i_
REN. 02-18-15 4.0003
owl
SHEET TITLE
TITLE SHEET__
SHEETNUMBER:REVISION:
T-1
0
SE03XC408
GENERAL NOTES:
1. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND NETWORK CARRIER
OF ANY ERRORS, OMISSIONS, OR INCONSISTENCIES AS THEY MAY BE
DISCOVERED IN PLANS, DOCUMENTS, NOTES, OR SPECIFICATIONS, PRIOR
TO STARTING CONSTRUCTION INCLUDING, BUT NOT LIMITED BY, DEMOLITION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERROR,
OMISSION, OR INCONSISTENCY AFTER THE START OF CONSTRUCTION WHICH
HAS NOT BEEN BROUGHT TO THE ATTENTION OF ARCHITECT AND NETWORK
CARRIER CONSTRUCTION PROJECT MANAGER AND SHALL INCUR ANY
EXPENSES TO RECTIFY THE SITUATION. THE MEANS OF CORRECTING ANY
ERROR SHALL FIRST BE APPROVED BY ARCHITECT AND NETWORK CARRIER
CONSTRUCTION PROJECT MANAGER.
2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT
THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS
AFFECTING THE PROPOSED PROJECT. CONTRACTORS PRIOR TO THE
COMMENCEMENT OF CONSTRUCTION AND THE CONTRACTOR HAVING BEEN
AWARDED THIS PROJECT SHALL VISIT THE CONSTRUCTION SITE WITH THE
CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND
CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR
TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT/ENGINEER VERBALLY AND IN WRITING.
3. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN
THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF
WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED
THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR
SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING
THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE NETWORK
CARRIER PROJECT SCOPE AND THE INTENT OF THESE DOCUMENTS. THE
BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE
ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR
TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF
DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR
EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE.
4. 11517 COPIES OF DRAWINGS ARE NOT TO BE SCALED DUE TO
DISTORTIONS RESULTING FROM MULTIPLE REPROGRAPHIC COPIES. WRITTEN
DIMENSIONS TAKE PRECEDENCE OVER SCALES SHOWN ON PLANS.
5. OWNER, CONTRACTOR, AND NETWORK CARRIER REPRESENTATIVE SHALL
REVIEW AND CONFIRM THAT PROJECT SCOPE, DESIGN INTENT AND UTILITY
COORDINATION ITEMS ARE INCLUDED IN THE DRAWINGS AND
SPECIFICATIONS PRIOR TO THE START OF CONSTRUCTION.
6. THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION FROM NETWORK
CARRIER REPRESENTATIVE TO PROCEED WITH CONSTRUCTION PRIOR TO
STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE
CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS.
7. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED
HOURS TO AVOID DISTURBING NORMAL BUSINESS OR TENANTS.
8. THE CONTRACTOR SHALL PROVIDE NETWORK CARRIER PROPER INSURANCE
CERTIFICATES NAMING NETWORK CARRIER AS ADDITIONAL INSURED, AND
PROVIDE NETWORK CARRIER PROOF OF LICENSE(S) INCLUDING PE & PD
INSURANCE.
9. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED
IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY
RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE
WORK UNDER THE CONTRACT.
10. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS
ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED
OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE.
11. ALL WORK PERFORMED ON THE PROJECT ALONG WITH ALL MATERIALS
INSTALLED, SHALL COMPLY IN STRICT ACCORDANCE WITH ALL APPUCABLE
CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL LIKEWISE
ISSUE NOTICE TO ALL SUB -CONTRACTORS THAT THEY SHALL COMPLY WITH
ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF
ANY PUBLIC AUTHORITY, MUNICIPAUTY, UTIUTY COMPANY AND LOCAL/STATE
JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK.
12. A COPY OF THE GOVERNING AGENCY ISSUED AND APPROVED PLANS SHALL
BE KEPT IN A PLACE SPECIFIED BY THE GOVERNING AGENCY, AND BY
LAW, SHALL BE AVAILABLE AT THE JOB SITE FOR INSPECTION AT ALL
TIMES. THE ORIGINAL PERMIT SET PIANS ARE NOT TO BE USED BY THE
WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME
INFORMATION AS GOVERNING AGENCY APPROVED PLANS. THE CONTRACTOR
SHALL ALSO MAINTAIN ONE SET OF PLANS, IN GOOD CONDITION,
COMPLETE WITH ALL REVISIONS, ADDENDA. AND CHANGE ORDERS ON THE
PREMISES AT ALL TIMES UNDER THE DIRECT CARE OF THE
SUPERINTENDENT. THE CONTRACTOR SHALL SUPPLY THE NETWORK
CARRIER CONSTRUCTION PROJECT MANAGER WITH A COPY OF ALL
REVISIONS, ADDENDA, AND/OR CHANGE ORDERS AT THE CONCLUSION OF
THE WORK AS A PART OF THE AS -BUILT DRAWING RECORDS.
13. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACIUTIES
ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS
NOTED OTHERWISE.
14. THE CONTRACTOR SHALL STUDY THE STRUCTURAL, ELECTRICAL,
MECHANICAL, AND PLUMBING PLANS AND CROSS CHECK THEIR DETAILS,
NOTES, DIMENSIONS. AND ALL REQUIREMENTS PRIOR TO THE START OF
ANY WORK. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY
OF THE JOB SITE WHILE WORK IS IN PROGRESS UNTIL THE JOB IS
COMPLETE.
16. THE CONTRACTOR HAS THE RESPONSIBILITY OF LOCATING ALL EXISTING
UTILITIES SHOWN OR NOT SHOWN ON THE PLANS, ALONG WITH
PROTECTING THEM FROM DAMAGE. THE CONTRACTOR AND SUBCONTRACTOR
SHALL BEAR THE EXPENSES OF REPAIR AND/OR REPLACEMENT OF
UTILITIES OR OTHER PROPERTY DAMAGE RESULTING FROM OPERATIONS IN
CONJUNCTION WITH THE EXECUTION OF THE WORK.
17. ALL EXISTING CONSTRUCTION, EQUIPMENT, AND FINISHES NOTED TO BE
REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND WILL
BE REMOVED FROM THE SITE WITH THE FOLLOWING EXCEPTIONS:
A. PROPERTY NOTED TO BE RETURNED TO THE OWNER.
B. PROPERTY NOTED TO BE REMOVED BY THE OWNER.
18. THE GOVERNING AGENCIES, CODE AUTHORITIES, AND BUILDING INSPECTORS
SHALL PROVIDE MINIMUM STANDARDS FOR CONSTRUCTION TECHNIQUES.
MATERIALS, AND FINISHES USED THROUGHOUT THE PROJECT. TRADE
STANDARDS AND/OR PUBLISHED MANUFACTURERS SPECIFICATIONS MEETING
OR EXCEEDING DESIGN REQUIREMENTS SHALL BE USED FOR INSTALLATION.
19. WHEN ROOF TOP OR TOP FLOOR DECK TEMPORARY STAGING IS REQUIRED,
MATERIALS SHALL BE EVENLY DISTRIBUTED OVER ROUGH FRAMED FLOORS OR
ROOFS SO AS NOT TO EXCEED THE DESIGNED LIVE LOADS FOR THE
STRUCTURE. TEMPORARY SHORING AND/OR BRACING IS TO BE PROVIDED
WHERE THE STRUCTURE DOESN'T HAVE THE DESIGN STRENGTH FOR
ADDITIONAL LOADING.
20. SEAL ALL PENETRATIONS WITHIN FIRE -RATED AREAS WITH U.L. LISTED OR
FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THE SUBJECT
FACILITY AND OR PROJECT SITE.
21. BUILDING INSPECTORS AND/OR OTHER BUILDING OFFICIALS ARE TO BE
NOTIFIED PRIOR TO ANY GROUND DISTURBANCE, CONSTRUCTION, AND ANY
OTHER PROJECT EFFORT AS MANDATED BY THE GOVERNING AGENCY.
22. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF
NOT LESS THAN 2-A OR 2 -Al OBC WITHIN 75 FEET TRAVEL DISTANCE TO
ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION.
23. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING
IMPROVEMENTS, EASEMENTS, PAVING, CURBING, DURING CONSTRUCTION. UPON
COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY
HAVE OCCURRED DUE TO CONSTRUCTION ON OR ADJACENT TO THE
PROPERTY.
24. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE
DURING CONSTRUCTION DISPOSING OF ALL DIRT, DEBRIS, AND RUBBISH.
CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON
THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND
FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE.
25. NEW CONSTRUCTION INSTALLED ADJACENT EXISTING BUILDINGS OR
CONSTRUCTION SHALL ARCHITECTURALLY MATCH THE EXISTING IN TERMS OF
COLOR, TEXTURE, FINISH MATERIALS, ETC., EXCEPT AS NOTED IN THE PLANS
AND SPECIFICATIONS.
26. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BACKING, BLOCKING.
AND/OR OTHER ANCHORAGE DEVICES REQUIRED FOR THE INSTALLATION OF
FIXTURES, MECHANICAL EQUIPMENT, PLUMBING, HARDWARE, AND FINISH ITEMS
TO INSURE A PROPER AND CODE COMPLIANT INSTALLATION.
27. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING INSTALLATIONS THAT ARE
CONSTRUCTED LEVEL, ERECT, EVENLY ALIGNED, PLUMB AND TRUE BASED ON
THE CONSTRUCTION DRAWINGS. THE CONTRACTOR SHALL COMPARE EXISTING
CONDITIONS WITH THE PROPOSED DESIGN PRIOR TO CONSTRUCTION AND
REPORT ANY DISCREPANCIES OR INCONSISTENCIES TO THE NETWORK
CARRIER'S REPRESENTATIVE AND FURTHER TO THE A&E SUCH THAT THE NEW
INSTALLATION WILL LIKEWISE BE LEVEL, ERECT, EVENLY ALIGNED, PLUMB AND
TRUE. ARCHITECT AND NETWORK CARRIER SHALL BE NOTIFIED OF ANY
ERRORS, OMISSIONS, OR INCONSISTENCIES PRIOR TO ANY CONSTRUCTION.
28. THE CONTRACTOR IS TO PROVIDE PROTECTION FOR ADJOINING PROPERTIES
FROM PHYSICAL HARM, NOISE, DUST, DIRT, AND FIRE AS REQUIRED BY THE
GOVERNING AGENCIES.
29. WHERE SPECIFIED, MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS
AND/OR REVISIONS AVAILABLE AS REQUIRED BY THE GOVERNING AGENCY
RESPONSIBLE FOR RECORDING THE RESULTS.
30. THE CONTRACTOR IS RESPONSIBLE FOR THE STORAGE OF ALL MATERIALS
AND SHALL NOT STORE OR STAGE MATERIALS ON PUBLIC PROPERTY WITHOUT
A PERMIT TO DO SO FROM THE GOVERNING AGENCIES FOR THIS PURPOSE.
31. GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS
TO BE USED IN ALL CONDITIONS UNLESS ILLUSTRATED AND NOTED
OTHERWISE.
32. TRADES INVOLVED IN THE PROJECT SHALL BE RESPONSIBLE FOR THEIR OWN
CUTTING, FITTING, PATCHING, ETC., SO AS TO BE PREPARED PROPERLY BY
THE WORK OF OTHER TRADES.
33. ALL DEBRIS AND REFUSE SHALL BE REMOVED FROM THE PROJECT PREMISES
AND LEFT IN A CLEAN SWEPT CONDITION AT ALL TIMES BY EACH TRADE AS
THEY PERFORM THEIR OWN PORTION OF THE WORK.
34. NETWORK CARRIER DOES NOT GUARANTEE ANY PRODUCTS, FIXTURES, AND/OR
ANY EQUIPMENT NAMED BY A TRADE OR MANUFACTURER. GUARANTEE OR
WARRANTY THAT MAY BE IN EFFECT IS DONE THROUGH THE COMPANY OR
MANUFACTURER PROVIDING THE PRODUCT, FIXTURE. AND/OR EQUIPMENT
UNLESS SPECIFIC RESPONSIBIUTY IS ALSO PROVIDED BY THE
CONTRACTOR/SUBCONTRACTOR IN WRITTEN FORM.
35. CAUTION! CALL BEFORE YOU DIG! BURIED UTIUTIES EXIST IN THE AREA
AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE
ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO
CONSTRUCTION.
36. WHEN APPUCABLE, CONTRACTOR IS RESPONSIBLE TO CALL, COORDINATE AND
MAKE ARRANGEMENTS FOR R.O.W. AND/OR PRIVATE PROPERTY LOCATES
BASED ON SPECIFIC SITE REQUIREMENTS.
37. SEE CIVIL DRAWINGS FOR ADDITIONAL SITE INFORMATION AS APPLICABLE.
38. CONTRACTORS TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS
AND SUBMIT TO NETWORK CARRIER'S REPRESENTATIVE ALONG WITH REDUNED
CONSTRUCTION SET.
39. CONTRACTOR SHALL DOCUMENT ALL CHANGES MADE IN THE FIELD BY
MARKING UP (REDLINING) THE APPROVED CONSTRUCTION SET AND
SUBMITTING THE REDUNED ALONG WITH PHOTOGRAPHS PER NETWORK
CARRIER REQUIREMENTS.
40. CONTRACTOR SHALL COORDINATE AND SEEK APPROVAL OF ALL POWER DRAW,
INSTALLATION AND/OR MODIFICATIONS WITH POWER COMPANY, OWNER AND
JURISDICTION AS REQUIRED. CONTRACTOR SHALL REPORT POWER
INSTALLATION SOLUTION(S) TO NETWORK CARRIER REPRESENTATIVE, PROJECT
CONSTRUCTION MANAGER AND ARCHITECT.
41. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED
BY NETWORK CARRIER CONSTRUCTION MANAGER.
42. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY ALL
FAULTY, INFERIOR, AND/OR IMPROPER MATERIALS, DAMAGED GOODS, AND/OR
FAULTY WORKMANSHIP FOR ONE (1) YEAR AFTER THE PROJECT IS COMPLETE
ACCEPTING UNDER THIS CONTRACT BETWEEN THE OWNER AND THE
CONTRACTOR. EXCEPTION: THE ROOFING SUBCONTRACTOR SHALL FURNISH A
MAINTENANCE AGREEMENT FOR ALL WORK DONE, COSIGNED BY THE
CONTRACTOR, TO MAINTAIN THE ROOFING IN A WATERTIGHT CONDITION FOR A
PERIOD OF TWO (2) YEARS STARTING AFTER THE DATE OF SUBSTANTIAL
COMPLETION OF THE PROJECT, UNLESS OTHERWISE WRITTEN IN THE
CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR.
43. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR THE SAFETY
OF THE OWNER'S EMPLOYEES, WORKMEN, AND ALL TIMES DURING THE
CONSTRUCTION OF THE PROJECT.
44. THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ALL NECESSARY PERMITS
AND/OR FEES WITH RESPECT TO THE WORK TO COMPLETE THE PROJECT.
BUILDING
PERMIT APPLICATIONS SHALL BE FILED BY THE OWNER OR HIS
REPRESENTATIVE. CONTRACTOR SHALL OBTAIN PERMIT (UNLESS OTHER
ARRANGEMENTS HAVE BEEN MADE) AND MAKE FINAL PAYMENT FOR SAID
DOCUMENT(S).
45. NETWORK CARRIER'S REPRESENTATIVE SHALL REVIEW AND APPROVE SHOP
DRAWINGS AND SAMPLES FOR CONFORMANCE WITH DESIGN CONCEPT.
NETWORK CARRIER'S REPRESENTATIVE PROJECT APPROVAL OF A SEPARATE
ITEM SHALL NOT INCLUDE APPROVAL OF AN ASSEMBLY IN WHICH THE ITEM
FUNCTIONS.
46. ALL ANTENNAS MOUNTED ON ROOF SUPPORT FRAMES TO BE PROVIDED BY
NETWORK CARRIER.
47. CONTRACTOR SHALL PROVIDE HEAVY STEEL PLATES AT OPEN TRENCHES FOR
SAFETY AND TO PROTECT EXISTING GROUND SURFACES FROM HEAVY
EQUIPMENT UTILIZED DURING CONSTRUCTION.
48. CONTRACTOR SHALL PATCH AND REPAIR ALL GROUND SURFACES WITHIN THE
CONSTRUCTION AREA AS NECESSARY TO PROVIDE A UNIFORM SURFACE AND
MAINTAIN EXISTING SURFACE DRAINAGE SLOPES.
49. CONTRACTOR SHALL REPLACE EXISTING LANDSCAPE VEGETATION DAMAGED DUE
TO CONSTRUCTION ACTIVITIES, AND REPAIR, RESTORE AND MODIFY EXISTING
IRRIGATION LINES IF NECESSARY TO OPERATING CONDITION, PROVIDING FULL
COVERAGE TO IMPACTED AREAS.
50. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA
FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR,
CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER TO OBTAIN CONTACT
INFORMATION AND UTIUZE THE EXISTING ROOFING CONTRACTOR OF RECORD
FOR INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION TO THE ROOF,
AND HAVING THE WORK GUARANTEED UNDER THE ROOFING CONTRACTOR'S
EXISTING WARRANTY ENSURING 100% MOISTURE PROTECTION.
51. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS
WITHIN CONCEALED (SHROUDED) SUPPORT FRAMES OR TRIPODS, CONTRACTOR
SHALL COORDINATE WITH THE FRP DESIGNER/FABRICATOR TO ENSURE THAT
THE FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) EXISTING EXTERIOR
BUILDING FACADE MATERIALS, TEXTURES, AND COLORS. THE CONTRACTOR
SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK OR FLATHEAD AN
FASTENERS IN ALL FRP CONSTRUCTION. WHEN PHOTOSIMULATIONS ARE
PROVIDED, THE CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION
REPRESENTS WHAT IS INDICATED IN PHOTOSIMULATION. SHOP DRAWINGS
SHALL BE PROVIDED TO THE CONTRACTOR, CONSTRUCTION COORDINATOR,
AND ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION.
ANTENNA & COAX NOTES
VERIFY EACH COAXIAL CABLE LENGTH, DIAMETER, ROUTING, COLOR CODING AND ALL
APPURTENANCES WITH NETWORK CARRIER REPRESENTATIVE.
2. THE MAXIMUM COAXIAL CABLE LENGTH AND CORRESPONDING COAXIAL CABLE DLAMETER
HAS
BEEN ESTIMATED. THIS CABLE LENGTH IS APPROXIMATE, AND IS NOT TO BE USED FOR
FABRICATION OR CONSTRUCTION. ACTUAL ANTENNA CABLE LENGTH(S) MAY VARY FROM
ESTIMATED MAXIMUM LENGTH AND MUST BE VERIFIED. COAXIAL CABLE SHALL BE PROVIDED BY
NETWORK CARRIER REPRESENTATIVE.
3. ALL MAIN CABLES SHALL UTILIZE GROUND KITS, GROUNDED AS FOLLOWS:
A. NEAR ANTENNA RAD CENTER ELEVATION,
B. MIDDLE OF TOWER (MID -HEIGHT OF ANTENNA), IF CABLE RUN IS OVER 200',
C. BOTTOM OF TOWER,
D. AT MASTER GROUND BAR 3'-0" FROM MMBS-BBU CABINET.
4. ALL TOP JUMPERS SHALL BE LENGTHS AS SHOWN AND INSTALLED BY CONTRACTOR.
5. ALL MAIN CABLES SHALL BE COLOR CODED PER THE CABLE COLOR CODING DIAGRAMS AS
SHOWN ON RF SHEET(S) AND IN ACCORDANCE WITH NETWORK CARRIER SPECIFICATIONS.
6. BANDING SHALL BE IN ACCORDANCE PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN
RF SHEET(S) AND AS FOLLOWS:
A. MAIN UNE COLOR BANDS SHALL BE 2" WIDE. MAINTAIN 1" SPACING BETWEEN COLORS.
B. FREQUENCY COLOR BANDS SHALL BE 2" WIDE WITH NO SPACE BETWEEN COLORS.
C. JUMPER COLOR BANDS SHALL BE 1" WIDE. WITH 1" SPACE.
D. START COLOR BANDS 2" BEYOND WEATHERPROOFING.
E. START SELECTOR COLOR NEXT TO END CONNECTORS.
7. FINAL COAXIAL ANTENNA CABLE SIZES SHALL BE DETERMINED
ENGINEER. SEE ANTENNA SCHEDULE.
BY NETWORK CARRIER RF
8. SEE CONSTRUCTION MANAGER FOR ANTENNA SUPPORT ASSEMBLY TYPE.
ON
9. ALL COAXIAL CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE AT DISTANCES
NOT TO EXCEED 3' OR THE CABLE MANUFACTURES SPECIFICATIONS WHICHEVER IS LESS, WITH
HARDWARE SPECIFIED IN THE COAXIAL CABLE ROUTING DETAILS OF THE SUPPLIED STRUCTURAL
REPORT.
10. PROVIDE AT LEAST 6" OF SLACK IN THE MAIN COAXIAL CABLES AT THE ANTENNA MOUNTING
ELEVATION TO PROVIDE FOR FUTURE CONNECTOR REPLACEMENT.
52. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA
FRAMES WHERE ANCHORING TO AN EXISTING CONCRETE ROOF SLAB IS
REQUIRED, CONTRACTORS SHALL CONFIRM (PRIOR TO SUBMITTING BID) WITH
CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF
POST TENSION TENDONS WITHIN THE ROOF SLAB RESULTING FROM AN
UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING "AS -BUILT
DRAWING SET" HAVING INDICATED AN ORIGINAL DESIGN SOLUTION OF
REINFORCED CONCRETE W/ EMBEDDED STEEL REBAR. IN THE EVENT POST
TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE
PROVISIONS FOR X-RAY PROCEDURES (INCLUDED IN BID) FOR ALL
PENETRATION AREAS WHERE ANCHORING OCCURS.
53. GENERAL & SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING
TIES FOR ALL CABUNG TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS
(WHERE APPLICABLE). PLASTIC ZIP TIES SHALL NOT BE PERMITTED FOR USE
ON TOWER NETWORK CARRIER PROJECTS. RECOMMENDED MANUFACTURE
SHALL BE PANDUIT CORP. METAL LOCKING TIES MODEL NO. MLT4S-CP
UNDER SERIES -304 (OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC.
54. CONTRACTOR SHALL OBTAIN, REVIEW AND EXECUTE ALL NETWORK CARRIER
CONSTRUCTION STANDARDS (MOST RECENT REVISION) AS A PART OF THIS BID
AND CONSTRUCTION PROJECT.
55. CONTRACTOR SHALL OBTAIN, REVIEW AND EXECUTE ALL NETWORK CARRIER
CONSTRUCTION STANDARDS (MOST RECENT REVISION) AS A PART OF THIS BID
AND CONSTRUCTION PROJECT.
56. CONTRACTOR SHALL BE RESPONSIBLE TO SET ELECTRONIC TILTS FOR NEWLY
INSTALLED ANTENNAS UNDER THE CONDITION THAT THE CONTRACTOR OBTAIN
THE MOST RECENT COPY OF THE RF TILT INFORMATION SUCH THAT THE
ACCURATE CONTROLLER CAN BE ORDERED AND INSTALLED.
57. A STRUCTURAL ANALYSIS SHALL BE COMPLETED AND SUBMITTED TO THE
NETWORK CARRIER REPRESENTATIVE AND CONTRACTOR DEMONSTRATING
CAPACITY AT THE EXACT LOCATION OF EXISTING CONDITIONS TO SUSTAIN
ADDITIONAL HEAVY BATTERY CABINETS OR OTHER OUT OF SCOPE EQUIPMENT.
58. THE CONTRACTOR SHALL PROVIDE MATERIALS UST (BOM) TO THE NETWORK
CARRIER REPRESENTATIVE PRIOR TO CONSTRUCTION.
TENNA & HYBRID COAX NOTES
VERIFY EACH HYBRID CABLE LENGTH, DIAMETER, ROUTING, COLOR CODING AND ALL
APPURTENANCES WITH NETWORK CARRIER REPRESENTATIVE.
2. THE HYBRID CABLE LENGTH AND CORRESPONDING DIAMETER HAS BEEN ESTIMATED. THIS
CABLE LENGTH IS APPROXIMATE, AND IS NOT TO BE USED FOR FABRICATION OR
CONSTRUCTION. ACTUAL ANTENNA CABLE LENGTH(S) MAY VARY FROM ESTIMATED MAXIMUM
LENGTH AND MUST BE VERIFIED. EXCESS CABLE LENGTHS TO BE DRESSED IN A MANNER
APPROVED BY NETWORK CARRIER REPRESENTATIVE. CABLES CANNOT BE CUT TO FIT.
3. HYBRID CABLE INTERNAL GROUND WIRE TO BE GROUNDED AT TOP AND BOTTOM PER NETWORK
CARRIER SPECIFICATIONS.
4. EXCESS TOP 15' HYBRID CABLE FIBER JUMPERS TO BE DRESSED IN A MANNER APPROVED BY
NETWORK CARRIER REPRESENTATIVE, CANNOT BE COILED, MUST BE SECURED TO TOWER
MOUNTS.
5. ALL MAIN CABLES SHALL BE COLOR CODED PER THE CABLE COLOR CODING DIAGRAMS AS
SHOWN ON RF SHEET(S) AND IN ACCORDANCE WITH NETWORK CARRIER SPECIFICATIONS.
6. BANDING SHALL BE IN ACCORDANCE PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN ON
RF SHEET(S) AND AS FOLLOWS:
A. MAIN UNE COLOR BANDS SHALL BE 2" WIDE. MAINTAIN 1" SPACING BETWEEN COLORS.
B. JUMPER COLOR BANDS SHALL BE 1" WIDE. WITH 1" SPACE.
C. START COLOR BANDS 2" BEYOND WEATHERPROOFING.
7. FINAL HYBRID CABLE SIZES SHALL BE DETERMINED BY NETWORK CARRIER RF ENGINEER. SEE
CABLE SCHEDULE, BASED UPON FINAL RUN LENGTHS DETERMINED BY NETWORK CARRIER
REPRESENTATIVE.
8. ALL HYBRID CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE AT DISTANCES
NOT TO EXCEED 3' HORIZONTALLY OR 4' VERTICALLY OR THE CABLE MANUFACTURES
SPECIFICATIONS WHICHEVER IS LESS, WITH HARDWARE SPECIFIED IN THE COAXIAL CABLE
ROUTING DETAILS OF THE SUPPLIED STRUCTURAL REPORT.
Liti-ao/r
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
S r i n t>
P
CC6A NST �
0
-rte
P4CIf It TE LEC OY SE9YIC E5. LLC
506 2N0 AVE. SUITE 210
SEATTLE. WA 96104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
ISSUE DATE 02-26-14
ISSUED FOR:CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INITIALS
A
01/30/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
/
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-18 1=
0404
00100
SHEET TITLE
GENERAL NOTES
SHEET NUMBER:
N-1
REVISION:
0
SE03XC408
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY 8Y NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint>
?ii(?517V.
F
-0
'1
/
1".....
S 129tH
sr
ARO
'Op
ry N
oG�gMisy R/�f� F
R
TRUE MAGNETIC
NORTH NORTH
•
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA. WA 98178
KING COUNTY
/
//
_
I i
i
IP f
BUILDING NG ILII'
gIIII
\
ISSUED FOR CONSTRUCTION DWGS
REVISIONS
A
SITE
,11111111,
DATE
DESCRIPTION
INITIALS
PARCEL NO.: 0003800003
STRIP THRU 0 C IN SW 1/4
& OVER POR GL 4 IN SD SW 1/4
FT BN RR R/W
GENERAL NOTES
LEGAL DESCRIPTION:
THESE DRAWINGS WERE PRODUCED WfTHOUT THE
BENEFIT OF A CURRENT LAND SURVEY. ALL PROPERTY
LINES, EASEMENTS, SETBACKS AND EXISTING
CONDITIONS ARE APPROXIMATE AND SHALL BE VERIFIED
PRIOR TO START OF CONSTRUCTION.
JOHNS 8 -L -D -C #47 400FT
11-23-04 & SE 10-23-04
11-23-04 LY WLY OF 100
// ////
PROPERTY LINE
r 11,
I
EXISTING
SPRINT
EO
�Ao�
IP
--
/ //
11111
TING
OKIINNG
...."--
.../S\
/
\
BEXISTING
UILDING
IIID,
TRUE MAGNETIC
NORTH NORTH
..., -
..p., -
0
IIIIIiIi.
1/////, '/��j////
i PROPERTY LINE' I
r� � 6Y
= U
I � � EXISTING
q\ V/^ zaN 1 PARRKANG
c I
\ I EXISTING `Q� I \
TREE >S, I XISTING
7 �P SITE , P�r" G*
-=,.5 EXISTING SPRINT S
BUILDING
S\
EXISTING
BUILDING
SpA
AP ��.`�
.fr
4+i,, ‹.-_, EXISTING
PARKING
\
/
l'1-
A'A
.ffT
I-
4"
\
` }
IXISTING IIIIIb
BUILDING.
01%t
4.I,
O Pp.'
�QO
// G \
EXISTING
TREE i
/' /
iti
APN: 0003800003
ZONING: C
//
EXISTING
PARKING
AREA
APN: 0003800003
ZONING: C
loll
001 e5"
EXISTING
BUILDING \
•
"\
L//
7{1EEG •
\
/
L
24"x36" SCALE:
11"x17" SCALE:
1" =
1" =
150'-0"24"x36"
SITE PLAN
1
SCALE: 1" = 30'-0"
11•x17" SCALE 1" = 60'-0" 3D
ENLARGED SITE PLAN
2
300'-0" 150' 70" 160'
1� o D.
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY 8Y NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint>
?ii(?517V.
—r
rAcTELECOM r ,
va SERVICES.
506 260 AVE. SUITE 210
SEATTLE. WA 98104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA. WA 98178
KING COUNTY
ISSUE DATE 02-26-14
ISSUED FOR CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INITIALS
A
01/30/14
ISSUED FOR 905 CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 1005 CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-18-1=
1
SHEET TFILE
SITE PLAN &
ENLARGED SITE PLAN
SHEET NUMBERREVISION:
A-1
0
SE03XC408
EXISTING PCS (2'-6"X8'-6")
LP TANK/AREA
EXISTING SPRINT
EQUIPMENT CABINET
EXISTING SPRINT
CABLE ROUTE
EXISTING SPRINT
CABLE TRAY
EXISTING CHAIN
LINK FENCE
EXISTING SPRINT
2'-0"X2'-0" CABINET
EXISTING
TELCO BOX
EXISTING SPRINT ANTENNA
LOCATION AT EXISTING
MONOPOLE - PROPOSED
MODIFICATION LOCATION
111111111111!;II1,
I�iillill I;Illlj!'
EXISTING SPRINT
GPS ANTENNA
EXISTING SPRINT
PPC CABINET
MOUNTED ON 4"X4"
TUBE STEEL POST
EXISTING 80'-0"
AGL MONOPOLE
EXISTING UAM/CIENA BOX
MOUNTED ON H -FRAM E
EXISTING CONCRETE SLAB
EXISTING RETAINING WALL
EXISTING GENERATOR
EXISTING 4'-0"
ACCESS GATE
EXISTING SPRINT
TELCO CABINET
MOUNTED ON 4"X4"
TUBE STEEL POST
EXISTING METER
EXISTING SPRINT
EQUIPMENT/LEASE AREA AT
CONCRETE SLAB ON GROUND -
NO PROPOSED MODIFICATION
TRUE MAGNETIC
NORTH NORTH
24"x36" SCALE 1/2" = 1'-0"
11"x17" SCALE 1/4" = 1'-0"
2' 1' 0" 2'
COMPOUND PLAN
1
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint)
0 CC8A(?5ffi?
—i—
PACIFIC TELECOM5 . LLC
506.2N0 AVATTLE,EW. A961SUITE04 210
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
ISSUE DATE 02-26-14
ISSUED FOR:CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INIRALS
A
01/30/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-18-15
6_
SHEET TITLE
COMPOUND PLAN
SHEET NUMBER:REVISION:
A-2
0
SE03XC408
EXISTING PCS * \
(2'-6"X8'-6")
EXISTING ICE BRIDGE
0 CC8/41?5W?
LP TANK/AREA +�
7 f •
\
EXISTING SPRINT
EXISTING SPRINT i. f BOX
�
CABLE ROUTE O ��� \ MOUNTED
/ \ MOUNTED ON H -FRAME
EXISTING SPRINT i J CT / \ f
EQUIPMENT CABINET NV° }
EXISTING SPRINT G� / /%ISTING ��11. EXISTING SPRINT
2'-0"X2'-0" CABINET CONCRETE 'I� PCS 2'-0"X4'-0"
EXISTING SPRINT SLAB?
CABLE TRAY•11�
EXISTING SPRINT �
ICE BRIDGE
�' � �4/
EXISTING ��'�/ r•
\
TELCO BOX
i`� 1 EXISTING 4'-O"
As. \ /�\ '.� ' _'� ACCESS GATE
Ill/ }
EXISTING SPRINT \
METER BOARD 3'-0" + i�
WORKING CLEARANCE
1110
/�
IIIA
NOTE.
NO PROPOSED WORK TO EXISTING
A
III
I
AF
�%/
���•
SPRINT GROUND EQUIPMENT
ISSUED FOR 100% CONSTRUCTION
0 �. O �I1
A
•
QOG 9\�• +
1�
III'
`` `!%
10\ °'!I EXISTING SPRINT
, %� GPS ANTENNA
oyP 9 ,,..,:ns
IP,•
/% EXISTING SPRINT 1
\ �� •IN BBU CABINET
J,'•
MMES CABINET NORTH NORTH
//� EXISTING SPRINT TRUE MAGNETIC
1/ EXISTING CHAIN
EXISTING SPRINT o' LINK FENCE ��`
TELCO CABINET ��
EXISTING METER
MOUNTED ON 4"X4" I ' _
TUBE STEEL POST
EXISTING SPRINT
PPC CABINET /�i
EXISTING RETAINING WALL MOUNTED ON 4"X4"
TUBE STEEL POST
24"x36" SCALE: 1/4" = 1'-0
EQUIPMENT PLAN
1
. NOT USED
2
11"x17" SCALE 1/8" = 1'-0" 4' 3' 2 1 0 4'
L /4»/(
NOT USED
3
NOT USED
4
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint>
0 CC8/41?5W?
--1—
PACIFIC TELECOM SERVICE!, LLC
506 2ND AVE SUITE 210
SEATTLE, WA 98104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
ISSUE DATE 02-26-14
ISSUED FOR: CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
PETALS
A
01/30/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-18-1=
.00.04
SHEET TITLE
EQUIPMENT PLAN
SHEET NUMBER:REVISION:
A-3
0
SE03XC408
EXISTING SPRINT 1900MHz RRH
MOUNTED BEHIND ANTENNA
"
(1 PER SECTOR, 3 TOTAL)
I
EXISTING SPRINT 1900MHz ANTENNA ��-,�,
e II �i"
(1 PER SECTOR, 3 TOTAL)
I
ei
EXISTING EMPTY
PIPE MOUNT (NP)
.o'"•��III
1
ij l�`. G e
I
I4? '�
ww
e
\
EXISTING 80'-0" ''II ;,
III
AGL MONOPOLE
,,III, e
.IIIIIIIIU'
e
°
(P\ C-1. -7\0r�% NORM NORMO
7 \0 1-6..\1)\ ds
4-\-O 2\
24"x36" SCALE: 1/2" = 1'-0"
I
1
NOT USED
2
I EXISTING ANTENNA PLAN
11"x17" SCALE: 1/4" = 1'-O" 2' 1' 0 2'
PROPOSED SPRINT
IIIIIIIII FILTER MOUNTED BEHIND
'IIIIIII ANTENNA, BELOW RRH
(1 PER SECTOR, 3 TOTAL)
NOTE
STRUCTURAL ANALYSIS MUST BE PREFORMED ON ALL ROOFTOPS, FLAGPOLES AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, NEW RRUS, & NEW CABINETS/TEMPORARY
PLATFORM.
NOTE
EXISTING ANTENNAS ARE CDMA UNLESS NOTED OTHERWISE.
NEW SPRINT ANTENNAS INCLUDE RESPECTIVE RRU'S WHICH SHALL BE MOUNTED ON THE PIPE BEHIND THE ANTENNA.
FIELD VERIFY EXISTING AZIMUTH BEFORE RELOCATING THE ANTENNA, IF REQUIRED. PRIOR APPROVAL FROM SPRINT TO BE GRANTED BEFORE RELOCATION OF ANTENNAS.
NOTES
ALL AZIMUTHS ARE TO BE ESTABUSHED CLOCKWISE FROM THE TRUE NORTH HEADING. CONTRACTOR SHALL VERIFY NEW ANTENNA RAD CENTER AND ORIENTATIONS WITH SPRINT PCS
PRIOR TO INSTALLATION OF ANTENNAS. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, EXISTING TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LICENSED
STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING THE NEW LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS. CONTRACTOR SHALL REFER TO TOWER
STRUCTURAL CALCULATIONS FOR ADDITIONAL LOADS. NO ERECTION OF MODIFICATION OF TOWER SHALL BE MADE WITHOUT APPROVAL OF STRUCTURAL ENGINEER.
PROPOSED SPRINT
2.5GHz RRH MOUNTED 1!1
`k BEHIND ANTENNA IIID
(1 PER SECTOR, 3 TOTAL)
EXISTING SPRINT 1900MHz RRH
MOUNTED BEHIND ANTENNA PROPOSED SPRINT
2.5GHz ANTENNA MOUNTED III!III
ISSUED FOR 905 CONSTRUCTION
(1 PER SECTOR, 3 TOTAL) N EXISTING MOUNT 'x:1111
(1 PER SECTOR, 3 TOTAL)
EXISTING SPRINT 1900MHz ANTENNA
e
l °
III.
IIII
(1 PER SECTOR, 3 TOTAL)
NG P \ai ISI
nu-- P�\M /
\%125 �;��
..s0.'‘.1,\)\\
4-i F'D
�l2
EXISTING EMPTY
PIPE MOUNT (TYP)
„II ;'" �r1F'
11P: {! 4°,,....<�p''" P,1
G/OR\,����
�� S, PI
`� ., 6�
`
NP
_.--.
\.;1
AF
RRU /HYBRID CABLE SCHEDULE
SECTOR
RRU MODEL
RRU FREQUENCY
HYBRID CABLE
LENGTH
HYBRID CABLE
DIAMETER
JUMPER
SZ2"
JUMPER
LENGTH
RET
LENGTH
RET CABLE
MANUFACTURER
RET CABLE
MODELNUMB
ALPHA
RRH-V3
2.5 GHz
1\\
AMODBE
6
BETA
RRH-V3
2.5 GHz
125'
N/AN
1/2"
6'
9.8'
COMMSCOPE
ATCB-B01-006
LICENSURE
4072 REGISTERED
'' ARC IT T
THOMAS R. HOLLAND 1
STATE OF WASHINGTON
REN. 02-18-15 0.00.3
osi
GAMMA
RRH-V3
2.5 GHz
125'
N/A
1/2"
6'
9.8'
COMMSCOPE
ATCB-B01-006
ANTENNA SCHEDULE
°
e
EXISTING 80'-0" ;.
SECTOR
ANTENNA
FREQUENCY
ANTENNA
MFR.
ANTENNA
MODEL
ANTENNA
QUANTITY
AZIMUTH
RAD CENTER
ANT. SZE
ELECT TILT
MECH TILT
ALPHA
2.5 GHz
KMW
ET-X-WM-18-65-81.
1 (PER SECTOR)
60'
77'-0"
61.0"
0'
0'
BETA
2.5 GHz
KMW
ET-X-WM-18-65-81.
1 (PER SECTOR)
155'
77'-0"
61.0"
0'
0'
AGL MONOPOLE II"
-VIII
IIIIIII:II'
N
j\
;.:: :�• \\1i SiS
�G
' ct5\-A �..,
3
1;\
--\"3
, ,
1-\..
°
16.5'
�n
\O TRUE YAONEnc
NORTN NORTH
.G�\tea
�l\A I� '
\ 1
•t
GAMMA
2.5 GHz
KMW
ET-X-WM-18-65-8P
1 (PER SECTOR)
240'
77'-0"
61.0"
0'
0'
NOTE:
STRUCTURAL ANALYSIS MUST BE
ON ALL S
FLAGPOLESPREFORMEAND TOWER SITES
BEFORE INSTALLATION OF NEW
ANTENNAS, NEW RRH UNITS, & NEW
CABINETS/TEMPORARY PLATFORM.
ANALYSIS TO BE PERFORMED BY
REGISTERED STRUCTURAL ENGINEER.
Llq.00,,r
24"x36" SCALE: 1/2" = 1' -0",
3
NOTES & ANTENNA SCHEDULE
4
11"x17" SCALE: 1/4" = 1'-0" 2' 1' 0" 2' ANTENNA PLAN
IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint>
0 CC6A(?5"ifr?
—rteTELECOM
EEVICES, C
506 2ND AVE, SUITE 210
SEATTLE, WA 96104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
ISSUE DATE 02-26-14
ISSUED FOR:CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INITIALS
A
01/30/14
ISSUED FOR 905 CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 1005 CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
'' ARC IT T
THOMAS R. HOLLAND 1
STATE OF WASHINGTON
REN. 02-18-15 0.00.3
osi
SHEET TITLE:
ANTENNA PLANS &
SCHEDULES
SHEET NUMBER:REVISION:
A-4
0
SE03XC408
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint>
0 CC6A?9fff?
NOTE'
STRUCTURAL ANALYSIS MUST BE
PREFORMED ON ALL ROOFTOPS,
FLAGPOLES AND TOWER SITES
BEFORE INSTALLATION OF NEW
ANTENNAS, NEW RRH UNITS, & NEW
CABINETS/TEMPORARY PLATFORM.
ANALYSIS TO BE PERFORMED BY
REGISTERED STRUCTURAL ENGINEER.
PACIFIC TELCCOY SERVICES. LLC
505 280 AVE, Swop
SEATU.E, WA 80104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
\
LSSUEDFOR CONSTRUCTION DWGS
REVISIONS
\
DATE
DESCRIPTION
INIMLS
A
01/30/14
ISSUED FOR 90% CONSTRUCTION
PROPOSED SPRINT
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
2.5GHzMOUNTED
II
III—
TOP OF EXISTING MONOPOLE
79'-7'
TOP OF PROPOSED SPRINT PANEL ANTENNAS
77'-0'
•
....
_i111
"1
ON EXISTING MOUNT
(1 PER SECTOR, 3 TOTAL)IIIIII;II
PROPOSED
TOP OF EXISTING MONOPOLE
79'-T
TOP OF EXISTING SPRINT PANEL ANTENNAS
77-0'
1
SPRINT
2.5GHz RRH MOUNTED III (III
BEHIND ANTENNA ° III'I
(1 PER SECTOR, 3 TOTAL)(
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-18-1=
0.00.3
SHEET TITLE
EXISTING & PROPOSED
SOUTHEAST ELEVATION
SHEET NUMBER:
A-5
PROPOSED SPRINT
FILTER MOUNTED BEHIND ,1111111
ANTENNA, BELOW RRH lil
(1 PER SECTOR, 3 TOTAL)
11 lel
EXISTING SPRINT 1900MHz RRH
MOUNTED BEHIND ANTENNA
(1 PER SECTOR, 3 TOTAL)
EXISTING SPRINT 1900MHz RRH
MOUNTED BEHIND ANTENNA
(1 PER SECTOR, 3 TOTAL)
EXISTING SPRINT 1900MHz ANTENNA
(1 PER SECTOR, 3 TOTAL)
41.
_
COSTING SPRINT 1900MHz ANTENNA
(1 PER SECTOR, 3 TOTAL)
RAD CENTER OF EXISTING SPRINT PANEL ANTENNAS
EXISTING OTHER CARRIER
ANTENNAS ARRAY
RAD CENTER OF EXISTING/PROPOSED SPRINT PANEL ANTENNAS
EXISTING OTHER CARRIER
ANTENNAS ARRAY
EXISTING 80'-0" AGL MONOPOLE
EXISTING 50•-0" AGL MONOPOLE
0
I
EXISTING SPRINT CABLE
ROUTE INSIDE MONOPOLE
0
1
m
•
EXISTING SPRINT CABLE
ROUTE INSIDE MONOPOLE
EXISTING SPRINT TELCO
CABINET MOUNTED ON
4"X4" TUBE STEEL POST
a (STING SPRINT
IXISTING SPRINT TELCO
CABINET MOUNTED ON
4"X4• TUBE STEEL POST
EQUIPMENT CABINETS
EXISTING SPRINT
EQUIPMENT CABINETS
DUSTING SPRINT
GPS ANTENNA
EXISTING SPRINT
GPS ANTENNA
EXISTING SPRINT
UPPER ICE BRIDGE
EXISTING
EXISTING SPRINT
UPPER ICE BRIDGE
IXISTING
UAM/CIENA
BOX MOUNTED ON
H -FRAME
.,
UAM/CIENA
BOX MOUNTED ON
H -FRAME
EXISTING SPRINT
EXISTING SPRINT
I•,N„
}'e.•
:0..
,�- ,
ee
•'S:•\,
e e. :�:�:�{�:•::::':•..•.
.0.e• i:L:Y:•
.•
•
.....
�.iA^i
\"}
.
: Ve• O•f:f•
:•:•1 i•}}''::�:�J.�.}•;'i
.
� LOWER ICE BRIDGE
i;:• e Y•1eY}'•i}i�1:�1::�:•:•::•::•:ti1:•:•:•''::':i:•:❖:❖
:•YJr:•''r ''r.
i'::i;ii
�
j0.1:•J••:.•:':4❖:ti
r
:ii
LOWER ICE BRIDGE
GRADE
,,.
e:• ::ti:•
:}i::::•i:•:•:•:
q.,; •dry
��;: ., e,
:•. e..
EXISTING 6•-0" HIGH
CHAIN LINK FENCE••'•"•
GRADE
:•:1.:•
»0..
...�.__-
e,,,e.
0..,.,{e.4,.,:•::•::•::
eee•....:•ee•••ev::r•
:•
• ...........
...... ..
EXISTING 6•-0" HIGH
CHAIN UNK FENCE
L. /4/ - Oar
24•x36• SCALE: 3/16• = 1•-0" .m.=
EXISTING SOUTHEAST ELEVATION
1
24•x36• SCALE: 3/16" = 1•-0•
,• PROPOSED SOUTHEAST ELEVATION
2
,rxn" scALE: 3/32" = r—Q• 4
11•x17• SCALE: 3/32" = 1 -0 4' 2 0 4'
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint>
0 CC6A?9fff?
—i—
PACIFIC TELCCOY SERVICES. LLC
505 280 AVE, Swop
SEATU.E, WA 80104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
ISSUE DATE 02-26-14
LSSUEDFOR CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INIMLS
A
01/30/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-18-1=
0.00.3
SHEET TITLE
EXISTING & PROPOSED
SOUTHEAST ELEVATION
SHEET NUMBER:
A-5
REVISION:
0
SE03XC408
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint).
0 C?AYN
•-r-
NOTF•
STRUCTURAL ANALYSIS MUST BE
PREFORMED ON ALL ROOFTOPS,
FLAGPOLES AND TOWER SITES
BEFORE INSTALLATION OF NEW
ANTENNAS, NEW RRH UNITS, & NEW
CABINETS/TEMPORARY PLATFORM.
ANALYSIS TO BE PERFORMED BY
REGISTERED STRUCTURAL ENGINEER.
PACIFIC TELECOM SERVICES, LLC
506.2ND AVE.
ATTLE,WA 981SURE04 210
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 95175
KING COUNTY
TOP OF EXISTING MONOPOLE
79'-7.
ISSUED FOR CONSTRUCTION DWGS
REVISIONS
,I,
DATE
DESCRIPTION
PROPOSED SPRINT
A
TOP OF EXISTING MONOPOLE
79'-3"
ISSUED FOR 90% CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
2.5GHz ANTENNA MOUNTED
'.::
Nil
_'I I
EXISTING MOUNT ,111!;111
(1 PER SECTOR, 3 TOTAL) 11111;1
0
PROPOSED SPRINT
2.5GHz RRH MOUNTED 11111111
BEHIND ANTENNA Ilnr1
(1 PER SECTOR, 3 TOTAL) 'ILII
II
PROPOSED SPRINT
FILTER MOUNTED BEHIND III'
ANTENNA, BELOW RRH Ii IIIIII
(1 PER SECTOR, 3 TOTAL)
III
—
EXISTING SPRINT 1900MHz RRH
MOUNTED BEHIND ANTENNA
(1 PER SECTOR, 3 TOTAL)
EXISTING SPRINT 1900MHz RRH
MOUNTED BEHIND ANTENNA
(1 PER SECTOR, 3 TOTAL)
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
EXISTING SPRINT 1900MHz ANTENNA
4-
J
SHEET NUMBER
A-6
(1 PER SECTOR, 3 TOTAL)
SE03XC408
'
I
..
EXISTING SPRINT 1900MHz ANTENNA
(1 PER SECTOR, 3 TOTAL)
RAD CENTER OF EXISTING/PROPOSED SPRINT PANEL ANTENNAS
EXISTING OTHER CARRIER
ANTENNAS ARRAY
RAD CENTER OF EXISTING SPRINT PANEL ANTENNAS
EXISTING OTHER CARRIER
ANTENNAS ARRAY
EXISTING 50'-0" AGL MONOPOLE
EXISTING BO' -0" AGL MONOPOLE
0
m
EXISTING SPRINT CABLE
ROUTE INSIDE MONOPOLE
0
m
EXISTING SPRINT CABLE
ROUTE INSIDE MONOPOLE
EXISTING 6'-0" HIGH
CHAIN LINK FENCE
EXISTING 6'-0" HIGH
CHAIN LINK FENCE
EXISTING SPRINT
GPS ANTENNA
EXISTING SPRINT
GPS ANTENNA
EXISTING SPRINT ICE
BRIDGE
EXISTING SPRINT ICE
BRIDGE
EXISTING SPRINT
EQUIPMENT CABINETS
/
EXISTING SPRINT
EQUIPMENT CABINETS
/CEG SPRINT TELCO
CABINET MOUNTED ON
4"X4" TUBE STEEL POST
11
CAESPRINTTELCO
CABINET MOUNTED ON
4"X4" TUBE STEEL POST
GRADE
••:�fi:�:•:�::❖:•:fi:::�:$•$c_�:
...•_..I•:•I'❖::•
:•
GRADE
••'•:::':�:�Sk•''�:::Z.Z
i :1�:......
Li?-' 00/8'
\
•�
24"x36" SCALE: 3/16" = i'—O" ..,- EXISTING SOUTHWEST ELEVATION
1
24"x36" SCALE: 3/16" = 1'-0" PROPOSED SOUTHWEST ELEVATION
2
11"x17" SCALE: 3/32" = 1'-0" 4 2 0 4'
11"x17" SCALE: 3/32" = 1 —0 4' 2 0" 4'
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint).
0 C?AYN
•-r-
PACIFIC TELECOM SERVICES, LLC
506.2ND AVE.
ATTLE,WA 981SURE04 210
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 95175
KING COUNTY
ISSUE DATE 02-26-14
ISSUED FOR CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INIVAS
A
01/30/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-1&1=
4004
SHEET TTILE
EXISTING & PROPOSED
SOUTHWEST ELEVATION
SHEET NUMBER
A-6
REVISION:
0
SE03XC408
IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint)
MECHANICAL
DOWNTILT
12.0 BRACKET 4.3
Power Junction Cylinder
_ Connector Shape
Steel bene point (20nYn)
PANEL ANTENNA WITH
MOUNTING HARDWARE
ANTENNA PIPE
MOUNT, SAMSUNG OR `,1—�
MOUNTING PIPE
(LENGTH TO SUIT)
2.5 GHz RRH
FIBER k
Fiber Junction Cylinder
ISSUE DATE 02-26-14
'
REVISIONS
REV.
DATE
DESCRIPTION
\
A
01/30/14
\
Oj Ffta hC
zanduct
5�
0
—
AL
APPROVED EQUAL
RRH MOUNTING
HARDWARE, SAMSUNG
OR APPROVED EQUAL ,
EXISTING
11111
POWER CABLES
FlBER k
POWER
CABLES
FROM
FROM RF
CABINET
MANUFACTURER: KMW COMMUNICATIONS,!
MODEL ET-X-WM-18-65-8P (2.SGH2)
WEIGHT: 36.4 LBS
DIMENSIONS (LBWBD): 61.0" X 12.0" X 4.3"
FREQUENCY: REFER TO RF DATA SHEEP
Si
A 7/ _
I • 1 .,I,a,. Fr, _ .
•!�1 ''_� /, r. ii Li
�, ..
cit r'0Cv
10 �_�
30
V
.,
F
12.0 12.0
0
MOUNTING FRAME
-KID
'1 ,T'1
Off`
aw
30 I I l f T'1' .I
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND 1
STATE OF WASHINGTON
REN. 02-18-15
..0011
SHEET TITLE
EQUIPMENT DETAILS
u�_
REVISION:
0
1.+�er Y` \ '�
-4BV a
Buchu .. Bushar );•±cS/
y
261
'�
�,
. 9• 00.11
■I—
ill
FIBER de POWER
CYLINDERS.
CONTRACTOR
SHALL MOUNT WITH
ADEQUATE HARDWARE
_
n
`rd
1 G� 1
20C
w
�Twy'>
liri
L�
K�b Kfb}
Ma BOTTOM
200
,k7F
,lr
RF CONNECTOR, TYP
REMOTE ELECTRICAL
'
NOTE:
VERIFY EXISTING CONDITIONS -allinlila
ALL MOUNTING CLAMPS AND
HARDWARE SHALL BE VERIFIED BY
TOWER ACCESSORY MANUFACTURER
TO EXISTING FRAME.
JUMPER (TYP.)
^pi1 OON°r
aur Gla.
ws•7.
.—
vnbrOwOf'-
:�, 7
Q 0
DOWNTILT ACTUATOR, TYP
.. .• \ \
22•x34" SCALE: NOT TO SCALE
11"x17" SCALE: NOT TO SCALE
MOUNTING DIAGRAM'. 1
22•x34• SCALE: NOT TO SCALE
11 " x17 " SCALE: NOT TO SCALE
2.5GHZ ANTENNA
2
22•x34• SCALE: NOT TO SCALE FIBER JUNCTION CYLINDER
11•x17" SCALE: NOT TO SCALE
3A
22"x34• SCALE: NOT TO SCALE
11•x17• SCALE: NOT TO SCALE POWER. JUNCTION CYLINDER
3B
MOUNTING BRACKET
AND HARDWARE
-
15.5
Sprint STBR 2.5G STBR radar filler 2496-2690MHz
Spn11 STBR2 SO radar tiller consists 01 Neluni9I badpass litter. 8 channel
Designed for ami.imerfercnte.
• Suitable for indoor or outdoor appli:dfwn.
nn.:
Seoeilialn
-- -- - - - - — -
furs lvmd 7:191-,-.1690 NOV: •A
hoe:bort Loss 406411 (AiLe.,e for a IDMI h 421 i'I <
q17 dH (A.'a:901Iia inn InMIL•411V—K3 14'1 � -
I'uwiLul l<gple gin] 1111 i r
aclumloSs IS Jai +?)1'
>14 dlt-luC-.ssr .. p
SAMSUNG OR
APPROVED EQUAL
SPFCIFICATIONS
ANTENNA
MECHANICAL
IH}
{ 111
I
1
11
11 111
11
11,
MOUNTING PIPE
HxWxD: 382x584x240mm
(18.6"x15.5 -x9.45')
III
III
11
11111111
<
ANTENNA
11
MOON
MOUNTING PIPE
MOUNTING BRACKET
WEIGHT: 59.5 LBS
I i1111111111111111
I11111111
AND HARDWARE -
SAMSUNG OR
APPROVED
9.45 PLAN
EQUAL
t'!rw
uliuull
tn
m
o
co
li' i!
j III III
I I I
1
!:°:°0%:20°°.:0::::.°:20°0%°:
I' !•i
I,
!I
III
°•
aaaaaaaaaa°aaa°
¢
I
ILII
I IIII
to
j
i
LT.'ca,
°°°°
a°
t.
of
'
o°° o°
o ° 0 0 0 ° °a
MOUNTING
AND HARDWARE
SAMSUNG
BRACKET
-
OR
_
,,,I �'
00°1°0°o °a
0
° o ° a ° ° o ° o°°°O°°°°°°
° ° ° ° °
00°01 ° °°° a
o a a a a a a ° O ° °
alk lur:wu +« dB ,.27x1-2941". MW
_
U. .,kla• <41 ns V24'96-2690 MIS
tmxe 41: til ._15'.
1.145 Imp. roma 90 w (As, .xsL liana altitude,
201nn all4
1a, 0 0..1, .9913 112011m44411
1.1.men 1,141, ,111 (Am 1/,o Nth:
0 �
APPROVED
EQUAL
III
• 17 d ❑ G G C 1:f
I:1
ANTENNA
1 .tut
MOUNTING
PIPE
r�
SIDE FRONT
22"x34" SCALE: NOT TO SCALE
11"x17• SCALE: NOT TO SCALE
RRMOUNTING22•x34•
4H
SCALE: NOT TO SCALE 2.5GHZ RRH-V3
11•x17" SCALE: NOT TO SCALE
5
Into -modulation < -120 dlic i1" orJ¢ „illi .1> 4:1411m1
^1 '"..
INroln'n,y J.mee RI st r 1"Y
boon Ing letup:Mum -11/11-•1SSl' o. - LNMowninp Options. 0
J; 1 n Rad:Y6ttcr
Como:t°n 1mmdNN f ale
Vit; L x Bakelite
.kvdwxaln iNan ° aul,lr,r •- (:i: ,I n 6unlalion Bushing '4eV"•.y
We1,JG can kg t , �- q 4 ♦Boll: AIB s 25
Dimensions i117'r:2nii:77mn a• N•_
ON incline eeannq te.le11 I x WaShing:Alx
- _ <; '1. X Scmw: N112s ?S1/
(•. I .X Bmckcl
L.sNl1I: M12 O
—, -no v.
O
. `.
O
a '
■ep„
EQUIPMENT
RF
URDU
-ANTENNA
per,
'I
ED
—
�I
••
4) FlBER
POWER
AND DC
CABLES
5) CPRI CABLE
T
—
•R R .
,
`—
U
1
00,80TGB
JUNCTION
CYUNDERS
I'p
6) RET CABLE
i111111IIIIJ•LIIIIIIIIPIIIII
'1
,JIIIIIDIIIIIIIIIIIIIIIIIOIIIII
3) RRH GROUND CABLE
7) RF JUMPERS
FEEDER UNE GROUND CABLE
(GROUND KIT/7/8 IN.
FEEDER UNE OR MORE)
MGB
"1)
MGB GROUND CABLE N
AND GROUND ARE USED IN CASE
OF THE 7/8 IN. FEEDER
ER LINE OR MORE
22"x34" SCALE: NOT TO SCALE
11"x17• SCALE: NOT TO SCALE SAMSUNG MMBS WIRING DIAGRAM
6
22•x34" SCALE: NOT TO SCALE
11"x17• SCALE: NOT TO SCALE FILTER SPECIFICATIONS
7
IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint)
0 cc8A°9ffiE`i
PACIFM TELECOM SERVICES. LLC
5013
SE2NDATf1E, WAVE, A 9015UITE04 210
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
ISSUE DATE 02-26-14
ISSUED FOR CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INITIALS
A
01/30/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND 1
STATE OF WASHINGTON
REN. 02-18-15
..0011
SHEET TITLE
EQUIPMENT DETAILS
SHEET NUMBER
A-7
REVISION:
0
SE03XC408
TYPICAL HYBRID CABLE COLOR CODE
SECTOR
FIRST RING
SECOND RING
THIRD RING
A
GREEN
NO TAPE
NO TAPE
B
GREEN
GREEN
NO TAPE
G
GREEN
GREEN
GREEN
FREQUENCY COLOR CODE FOR PAIRS
AND FIBER CABLES OF HYBRID CABLE
FREQUENCY COLOR CODE
FIRST RING
SECOND RING
1900 MHz
YELLOW
RED
TYPICAL JUMPER CABLE COLOR CODE
FREQUENCY
ANTENNA PORT
RRU PORT
CABLE
COLOR
1900 MHz
PCS1 -45'
ANT 0
BLUE
PCS1 +45'
ANT 1
WHITE
PCS2 -45'
ANT 2
GREEN
PCS2 +45'
ANT 3
BROWN
RET
RET
RED
NOTES
ON HIGH CAPACITY SITES OR ON FOUR -SECTOR SITES NEEDING AN ADDITIONAL UNE AND RRU
CONTACT GDR SITE SUPERVISOR FOR COLOR CODE INFORMATION ON ADDITIONAL LINES.
SUPPLIER
SAMSUNG FIBEROPTICS
ASIA TAI
TYPE
LENGTH
TOTAL WEIGHT
WEIGHT/LF
TOTAL WEIGHT
WEIGHT/LF
(FT)
(KG)
(LBS)
(KG)
(LBS)
(KG)
(LBS)
(KG)
(LBS)
TYPE 1
60
13
28
0.2
0.5
19
41
0.3
0.7
75
16
35
0.2
0.5
22
49
0.3
0.7
90
19
42
0.2
0.5
26
57
0.3
0.7
TYPE 2
105
30
66
0.3
0.6
29
65
0.3
0.7
120
34
75
0.3
0.6
33
73
0.3
0.7
135
38
85
0.3
0.6
46
101
0.3
0.7
150
43
94
0.3
0.6
51
112
0.3
0.7
165
47
104
0.3
0.6
55
122
• 0.3
0.7
TYPE 3
180
69
151
0.4
0.8
72
160
0.3
0.7
195
75
164
0.4
0.8
78
173
0.3
0.7
210
80
177
0.4
0.8
85
187
0.3
0.7
TYPE 4
225
89
196
0.4
0.9
102
224
0.3
0.7
240
95
209
0.4
0.9
109
239
0.3
0.7
255
101
222
0.4
0.9
115
254
0.3
0.7
TYPE 5
270
133
293
0.5
1.1
122
270
0.3
0.7
285
141
310
0.5
1.1
152
335
0.3
0.7
300
148
326
0.5
1.1
160
353
0.3
0.7
315
155
342
0.5
1.1
168
371
0.3
0.7
330
163
359
0.5
1.1
176
388
0.3
0.7
TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6 TYPE 7
TOTAL LENGTH
-114.-9.95"
-'180'-5.35"
-213'-3.05"
"262'-5.60"
«328'-1"
«420'-0"
-'550'-0"
HYBRID POWER
CABLE
CONFIGURATION
AWG 10 1 PAIR,
AWG 12 3 PAIR
AWG 8 1 PAIR,
AWG 10 3 PAIR
AWG 6 1 PAIR,
AWG 8 1 PAIR,
AWG 10 2 PAIR
AWG 6 1 PAIR,
AWG 8 3 PAIR
AWG 4 1 PAIR,
AWG 6 1 PAIR,
AWG 8 2 PAIR
AWG 4 1 PAIR,
AWG 6 3 PAIR
AWG 2 1 PAIR,
AWG 4 3 PAIR
CABLE DIAMETER
0.98"
1.06"
1.18"
1.18"/1.25"
1.25"
1.56"
1.69"
BENDING RADIUS
11.81"
12.99"
15.35"
17.71"
17.71"
18.00730.00"
21.00735.00"
OPTIC CABLE
LC/PC-to-LC/PC, SINGLE MODE
DU CABINET
(POWER CABLE
TERMINAL MAX
SIZE AWG 4)
2 PAIR POWER AND OPTIC CABLE WITH PE PIPE
RRU POWER
CABLE SPEC
AWG 8, 0.57""0.60"
AWG 10, 0.45"-'0.48"
8 AWG CABLES 4 PAIRS
NON USE POWER
AND OPTIC CABLE
PROTECTION
2 PAIR POWER
AND OPTIC CABLE
WITH PE PIPE
2 PAIR POWER
AND OPTIC CABLE
WITH PE PIPE
2 PAIR POWER
AND OPTIC CABLE
WITH PE PIPE
2 PAIR POWER
AND OPTIC CABLE
WITH PE PIPE
2 PAIR POWER
AND OPTIC CABLE
WITH PE PIPE
2 PAIR POWER
AND OPTIC CABLE
WITH PE PIPE
SUPPLIER
TESSCO
TYPE
LENGTH
TOTAL WEIGHT
(FT)
(KG)
(LBS)
ISSUED FOR:
CONSTRUCTION DWGS
REVISIONS
1
0.73
1.6
TYPE 6
1000
732
1613
AF
420
402
887
AF
1
1
2.2
TYPE 7
1000
1006
2218
550
553
1220
22"x34" SCALE NOT TO SCALE HYBRID AND JUMPER CABLES COLOR CODING
11"x17" SCALE NOT TO SCALE
1
22"x34" SCALE NOT TO SCALE
11"x17" SCALE NOT TO SCALE
HYBRID CABLE TYPES
2
(4) PAIR COPPER
TO RRU
(6) FIBER CABLES
2" TAPE 1" SPACE
FIRST RING BETWEEN
HYBRID COLOR CODE . RINGS
2" TAPE
SECOND RING
(IF APPLICABLE PER
SECTOR)
1" SPACE
BETWEEN
RINGS
2" TAPE
THIRD RING
(IF APPUCABLE PER
SECTOR)
2" SPACE
BETWEEN HYBRID
CABLE COLOR CODE
AND FREQUENCY
COLOR CODE
2" TAPE
FIRST RING
FREQUENCY COLOR
CODE
2" TAPE
SECOND RING
FREQUENCY COLOR
CODE
2" SPACE
FROM END OF
BREAK-OUT CYLINDER
HYBRID COLOR CODE
TAPE (SEE TABLE
FOR DETAILS)
(4) PAIR COPPER
TO CABINET
(6) FIBER CABLES
HYBRID COLOR CODE
TAPE (SEE TABLE
FOR DETAILS)
2" TAPE 1" SPACE
FIRST RING BETWEEN
HYBRID COLOR CODE . RINGS
HYBRID COLOR CODE
TAPE (SEE TABLE
FOR DETAILS)
2" TAPE
SECOND RING
(IF APPLICABLE PER
SECTOR)
1" SPACE
BETWEEN
RINGS
2" TAPE
THIRD RING
(IF APPLICABLE PER
SECTOR)
NO SPACE
BETWEEN CABLE
2" SPACE
BETWEEN HYBRID
CABLE COLOR CODE
AND FREQUENCY
COLOR CODE
2" TAPE
FIRST RING
FREQUENCY COLOR
CODE
FREQUENCY COLOR
CODE (SEE TABLE
FOR DETAILS)
2" TAPE
SECOND RING
FREQUENCY COLOR
CODE
2" TAPE RING 2" TAPE RING
1" SPACE SECOND RING 1" SPACE THIRD RING
2" TAPE RING BETWEEN (IF APPUCABLE PER BETWEEN (IF APPUCABLE PER
FIRST RING RINGS SECTOR) RINGS SECTOR)
HYBRID COLOR CODE
TAPE (SEE TABLE
FOR DETAILS)
2" SPACE
FROM END OF
BREAK-OUT CYLINDER
HYBRID COLOR CODE
TAPE (SEE TABLE
FOR DETAILS)
WRAP TAPE AROUND
CABLE. THREE TIMES,
MIN. (TYP)
HYBRID CABLE
TO CABINET
2" TAPE RING 2" TAPE RING
1" SPACE SECOND RING 1" SPACE THIRD RING
2" TAPE RING BETWEEN (IF APPLICABLE PER BETWEEN (IF APPLICABLE PER
FIRST RING RINGS SECTOR) RINGS SECTOR)
HYBRID COLOR CODE
TAPE (SEE TABLE
FOR DETAILS)
NOTE:
HYBRID COLOR CODE
TAPE (SEE TABLE
FOR DETAILS)
HYBRID COLOR CODE
TAPE (SEE TABLE
FOR DETAILS)
1. ALL CABLES SHALL BE MARKED AT THE TOP AND BOTTOM WITH 2" COLORED TAPE OR STENCIL TAG.
COLOR TAPE SHALL BE OBTAINED FROM GRAYBAR ELECTRIC.
2. THE FIRST RING SHALL E CLOSEST TO THE END OF THE CABLE AND SPACED APPROXIMATELY 2"
FROM AN END CONNECTOR, WEATHERPROOFING, OR BREAK-OUT CYLINDER, WITH 1" SPACE BETWEEN
EACH RING.
3. THE HYBRID CABLE COLOR SHALL BE APPUED IN ACCORDANCE WITH THE "TYPICAL HYBRID CABLE
COLOR CODE" TABLE ABOVE FOR THE RESPECTIVE SECTOR.
4. INDIVIDUAL POWER PAIRS AND FIBER CABLES SHALL BE LABELED WITH BOTH THE HYBRID CABLE
COLOR FOR THE RESPECTIVE SECTOR AND A FREQUENCY COLOR CODE IN ACCORDANCE WTTH THE
"FREQUENCY COLOR CODE FOR PAIRS AND FIBER CABLES OF HYBRID CABLE" TABLE ABOVE.
5. A 2" GAP SHALL SEPARATE THE HYBRID CABLE COLOR CODE FROM THE FREQUENCY COLOR CODE.
6. THE 2" COLOR RINGS FOR THE FREQUENCY CODE SHALL BE PLACED NEXT TO EACH OTHER WITH NO
SPACES.
7. THE 2" COLORED TAPE(S) SHALL EACH BE WRAPPED A MINIMUM OF 3 TIMES AROUND THE HYBRID
CABLE OR INDIVIDUAL CABLES, AND THE TAPE SHALL BE KEPT IN THE SAME LOCATION AS MUCH AS
POSSIBLE.
8. COLOR BAND ON JUMPERS SHALL 8E 2" WIDE WITH A 2" SPACE.
NO SPACE
BETWEEN CABLE
FREQUENCY COLOR
CODE (SEE TABLE
FOR DETAILS)
HYBRID CABLE CONNECTION AT CABINET
HYBRID COLOR CODE
TAPE (SEE TABLE
FOR DETAILS)
2 FROM RRU t
2" TAPE
SECOND RING
FREQUENCY COLOR
CODE
HYBRID COLOR CODE
TAPE (SEE TABLE
FOR DETAILS)
WRAP TAPE AROUND
CABLE. THREE TIMES,
MIN. (TYP)
2" TAPE 2" SPACE
FIRST RING BETWEEN CABLE CODE
FREQUENCY COLOR AND FREQUENCY
CODE COLOR CODE
HYBRID CABLE
TO RRU
2" TAPE
THIRD RING
CABLE #
1" SPACE
1" SPACE
2" TAPE
THIRD RING
CABLE #
2" SPACE
BETWEEN CABLE CODE
AND FREQUENCY
COLOR CODE
2" TAPE
FIRST RING
FREQUENCY COLOR
CODE
2" TAPE
SECOND RING
FREQUENCY COLOR
CODE
1 RRU & END
OF JUMPER
D ANTENNA END
OF JUMPER
JUMPER CABLE CONNECTION AT RRU AND ANTENNA
1 FROM ANTENNA
L/4 -0o/8'
22"x34" SCALE: NOT TO SCALE
11"x17" SCALE: NOT TO SCALE
HYBRID CABLE COLOR SCHEME DETAIL
3
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint).
0 CC8/61(.471V
-1-
pAcirm TELECOM SERVICES. LLC
506 2ND AVE. SURE 210
SEATTLE. WA 86104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL, S
TUKWILA, WA 98178
KING COUNTY
ISSUE DATE 02-26-14
ISSUED FOR:
CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INITIALS
A
01/30/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-18-1=
000.4
SHEET TITLE
ANTENNA AND CABLE
COLOR CODING DETAILS
SHEET NUMBER:
RF -1
REVISION:
0
SE03XC408
LEGEND
0 CCI?A?57WL EN
EXISTING SPRINT
ANTENNA GROUND BAR
(1 PER SECTOR, 3 TOTAL)/I
`11
\ -......,
\ \
\
11----;1111:"---
\'11111
e \\ \
\ \
`�� l\I! ,
��II\\
I Ili \1
.-
/ 1
° / 1Ifni'
/ /
/
/
v/
yrf;
/
e
I
II
.;:,,I��I
I�'
°
\
\ \ \ \
X. \
\
-" J \ \
\ \
\ \ \
\\ \ ��
;Il ° \ \
c\'•°• \
;1111111' \ \
a
`•
A „L� I•,`
•
tl"(
NEW SPRINT ANTENNA
REVISIONS
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION
AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS.
2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER
METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO
SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS
MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS.
GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR
POLE USING MFR'S PRACTICES.
3. ALL GROUND CONNECTIONS SHALL BE EXOTHERMIC. ALL WIRES
SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE
GREEN INSULATED WIRE ABOVE GROUND.
4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE.
GROUNDING AND OTHER OPERATIONAL TESTING WILL BE WITNESSED
BY SPRINT WIRELESS REPRESENTATIVE.
5. REFER TO DMSION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL
PROVISION AND COMPLY Wm -I ALL REQUIREMENTS OF GROUNDING
STANDARDS.
6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF
GROUNDING SYSTEM PER SPRINT STANDARD GROUNDING METHOD,
AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED SPRINT
WIRELESS REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING
SYSTEM. PHOTO DOCUMENT ALL EXOTHERMIC AND GROUND RING
7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES
INSTALUNG GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS.
8. ALL EXISTING GROUND BARS, WIRES & CONNECTIONS SHALL BE
FIELD VERIFIED. ANY DEFICIENT ITEMS SHALL BE REPLACED AS
REQUIRED TO ACHIEVE ADEQUATE GROUNDING REQUIRED BY SPRINT.
MOUNTING PIPE CONNECTED TO
EXISTING ANTENNA GROUND
BAR (1 PER SECTOR, 3 TOTAL)
NEW SPRINT RRU CONNECTED
TO EXISTING ANTENNA GROUND
BAR (1 PER SECTOR, 3 TOTAL)
CONNECTION FROM NBARS
INRNLS
A
GENERAL GROUNDING NOTES
SPRINT ANTENNA GROUD
TO EXISTING MASTER GROUND BAR
GROUNDING NOTES
1. EXOTHERMIC WELDS (2). 2 AWG BARE TINNED SOLID COPPER
CONDUCTORS TO GROUNDING BAR. ROUTE CONDUCTORS TO BURIED
GROUNDING RING AND PROVIDE PARALLEL EXOTHERMIC WELD.
2. EC SHALL USE PERMANENT MARKER TO DRAW THE LINES BETWEEN
EACH SECTION AND LABEL EACH SECTION ("P", "A", "N", "I") WITH
1" HIGH LETTERS.
WASHERS, COAT ALL SURFACES WITH AN ANTI -OXIDANT COMPOUND
BEFORE MATING. ALL HARDWARE SHALL BE STAINLESS STEEL 3/8
INCH DIAMETER OR LARGER.
4. FOR GROUND BOND TO STEEL ONLY: INSERT A CADMIUM FLAT
WASHER BETWEEN LUG AND STEEL, COAT ALL SURFACES WITH AN
ANTI -OXIDANT COMPOUND BEFORE MATING,
5. NUT & WASHER SHALL BE PLACED ON THE FRONTSIDE OF THE
GROUNDING BAR AND BOLTED ON THE BACK SIDE. INSTALL BLACK
TERMI ATIIONSING THE INTENT OIS VOTO WEATHERPROOF THE LT INSULATION ON ALL GROUNDING
COMPRESSION CONNECTION.
6. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE
TYPE OF TOWER, ANTENNA LOCATION, AND CONNECTION
ORIENTATION. PROVIDE AS REQUIRED.
7. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED
OR RECOMMENDED BY CABLE MANUFACTURER.
8. WEATHERPROOFING SHALL BE TYPE AND PART NUMBER AS
SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER.
9. SUPPLIED AND INSTALLED BY CONTRACTOR.
10. WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OF A
GROUNDING BAR TO AN EXISTING TOWER, THE SUBCONTRACTOR
SHALL OBTAIN APPROVAL FROM THE TOWER OWNER PRIOR TO
MOUNTING THE GROUNDING BAR TO THE TOWER.
11. EXTEND TWO (2) 2 AWG TINNED CU CONDUCTOR FROM BURIED
GROUNDING RING AND CONNECT TO THE NEW TOWER. FOLLOW
MANUFACTURERS RECOMMENDATIONS FOR GROUNDING CONNECTIONS
TO THE TOWER. (APPLICABLE TO NEW TOWERS ONLY.)
12. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE
TYPE OF TOWER, ANTENNA LOCATION, AND CONNECTION
ORIENTATION. THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR
INSTALLING ADDITIONAL GROUNDING BARS AS REQUIRED, PROVIDING
50% SPARE CONNECTION POINTS.
13. EXPOSED GROUND WIRES TO BE NON METALLIC LIQUID TIGHT.
Lill.. 00/g
BAR AEXISTIT GROUSPRINT MASTND LEVELR GROUND
EXISTING FINAL GROUND LEAD
FROM MASTER GROUND BAR TO
EXISTING MONOPOLE GROUND RING TRUE MAGNETIC
NORTH NORTH
=
ARC
0
• EXOTHERMIC CONNECTION
❑ MECHANICAL CONNECTION
o COMPRESSION CONNECTION
CGB COLLECTOR GROUND BAR
MGB EXTERNAL GROUND BAR
24"x36" SCALE: 1/2" = 1'-0" I
I
ANTENNA SCHEMATIC GROUNDING PLAN
1
11"x17" SCALE 1/4" = 1'-0" 2'
�
i 0"
2'
NOT USED 2
NOT USED
3
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint),
0 CCI?A?57WL EN
--i—
PACIFIC te
PACIFIC TELECOERVICES, LAS
506 2ND AVE, SURE 210
SEATTLE. WA 98104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL S
TUKWILA; WA 98178
KING COUNTY
ISSUE DATE 02-26-14
IssuEDFOR CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INRNLS
A
01/30/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
'
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-18-15 _
v
l
SHEET TITLE
ANTENNA SCHEMATIC
GROUNDING PLAN
SHEET NUMBER
E-1
REVISION:
0
SE03XC408
LIST. CGB
(ANTENNA SECTOR 11
EXISTING PROPOSED
900 MHz 2.5 GHz
ANTENNA ANTENNA
TCOAX JUMPER
HYBRID CABLE INTERNAL 1
GRD WIRE TO BE
TRIMMED TO FIT AND
ATTACHED TO GRD BAR --i
�E2 AWG
EXISTING GPS
ANTENNA
#10 AWG
ce
m
ce
8
0
0
EXIST. CGB
JUNCTION
CYLINDERS
(E) HYBRID
MEDUSA
(ANTENNA SECTOR 21
EXISTING
900 MHz
ANTENNA
PROPOSED
2.5 GH
ANTENNA
COAX JUMPER
0
HYBRID CABLE INTERNAL
GRD WIRE TO BE
TRIMMED TO FIT AND
ATTACHED TO GRD BAR
(E) #2 AWG
EXISTING UPPER
TOWER GROUND BAR
#10 AWG
— (E) HYBRID
MEDUSA
`^IST. CGB
—JUNCTION
CYLINDERS
m
[ANTENNA SECTOR 31
EXISTING
900 MHz
ANTENNA
PROPOSED
2.5 GH
ANTENNA
HYBRID CABLE INTERNAL
GRD WIRE TO BE
TRIMMED TO FR AND
ATTACHED TO GRD BAR
[COAX JUMPER
`JUNCTION
CYUNDERS
...JEL#WC
0
0
EXISTING DEI
CABINET
EXISTING
CABINET
EXISTING
MMBS
CABINET
7
#6 AWG WITH
WEATHERPROOFING
(E) #2 AWG
#2 AWG
az aE1 a 1
00 00 00
EMMBS GND BAR
HYBRID CABLE
INTERNAL GRD WIRE
TO BE TRIMMED TO
FIT AND ATTACHED
TO GRD BAR
EXISTING LOWER
TOWER GROUND BAR
EXISTING #2 AG
GROUNDS TO EXISTING
GROUND RING
EXISTING #2 AG
GROUNDS TO EXISTING
GROUND RING
C14-00/8°
(E) HYBRID
MEDUSA
LEGEND
• EXOTHERMIC CONNECTION
❑ MECHANICAL CONNECTION
o COMPRESSION CONNECTION
CGB COLLECTOR GROUND BAR
MGB EXTERNAL GROUND BAR
GROUNDING NOTES
1. ALL GROUNDING CONNECTIONS SHALL BE MADE BY MECHANICAL
CONNECTION. ALL CABLE TO GROUND RODS, GROUND RODS SPLICES AND
LIGHTING PROTECTIONS SYSTEM AS INDICATED. GROUND FOUNDATION ONLY
AS INDICATED BY PM. ALL MATERIALS USED SHALL BE INSTALLED PER
MANUFACTURERS RECOMMENDATIONS AND PROCEDURES. GROUND
CONDUCTOR SHALL HAVE A MINIMUM 24" BENDING RADIUS.
2. ALL MECHANICAL CONNECTIONS ON GALVANIZED SURFACES SHALL BE
CLEANED THOROUGHLY AND COLORED TO MATCH SURFACE WITH (2) TWO
COATS OF GALVITE (WHITE) PAINT. OR SILVERBRITE (ALUMINUM),
3. ALL ELECTRICAL & MECHANICAL GROUND CONNECTIONS SHALL HAVE
ANTIOXIDANT COMPOUND APPLIED TO CONNECTION.
4. GROUND TESTS SHALL BE PERFORMED AS REQUIRED BY SPRINT
STANDARD PROCEDURES. GROUND GRID RESISTANCE SHALL NOT EXCEED
5—OHMS.
5. CONTRACTOR SHALL SUBMIT THE GROUND RESISTANCE TEXT REPORT AS
FOLLOW:
1. ONE (1) COPY TO OWNER REPRESENTATIVE
2. ONE (1) COPY TO ENGINEER
3. ONE (1) COPY TO KEEP INSIDE EQUIPMENT INCLOSURE
6. ALL RADIO EQUIPMENT AND UTILITY CABINETS GROUNDS LEADS TO BE #2
AWG STRANDED GREEN JACKETED FROM BUSS TERMINAL.
7. ALL ANTENNA MOUNT GROUNDS SHALL BE #2 AWG STRANDED GREEN
JACKETED CABLE GROUNDS SHALL BE BLACK FROM MFR.
8. ALL GROUND WIRES FROM GROUND BARS TO GROUND SHALL BE #2 AWG
SOLID BARE AS REQUIRED.
9. ALL ABOVE GROUND WIRES SHALL BE GREEN JACKETED. ALL GROUND
WIRE'S PENETRATING INTO GROUND AND BELOW SHALL BE SOLID BARE.
TOWER GROUNDING STANDARD
1. EXISTING HOME RUN GROUND WIRES TO BE REMOVED.
2. ALL EXISTING AND EXISTING TOWER GROUND BARS TO BE MECHANICALLY
ATTACHED TO TOWER WITHOUT INSULATORS.
3. NO DRILLING OR WELDING TO TOWER PERMITTED
22"x34' SCALE: NOT TO SCALE
11'x17" SCALE NOT TO SCALE
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
GROUNDING RISER DIAGRAM
1
Sprint)
0 CC6ATTT?
—i—
PACIFIC TELECOM5, LLC
506 NO AVE, SUITE 210
SEATTLE, WA 96104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
ISSUE DATE
02-26-14
ISSUED FOR CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INITIALS
A
01/30/14
ISSUED FOR 907. CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 1005 CONSTRUCTION
AF
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND 1
STATE OF WASHINGTON
REN. 02-18-15 _
�1
l
SHEET TITLE
GROUNDING DETAILS
SHEET NUMBER:
E-2
REVISION:
0
SE03XC408
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint)
NOTES:
1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS
DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR.
2. WEATHER PROOFING SHALL BE ANDREWS. (TYPE & PART NUMBER
AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER.)
TO ANTENNAS
RXO TXO r` X1
IWEATHERPROOFING
1-1 1-1 KIT (TYP.)
to i I/KIT
GROUND
(TYP.) (SEEANTENNA
WEATHERPROOFING DET/3 E-5)
KIT •) r 11
SEE NOTE 2 1I1 1I1 ���" ANTENNA CABLE
TO SHELTER (TYP.)
—ANTENNA GROUND
/6 AWG KBAR, SIMILAR TO 166-057!
MOUNT
12- TO 24"
INSPECTION
WINDOW
REQUIRED FOR BUTT CONDUCTOR
ALL INTERIOR
EXTERNAL TWO -HOLE STION UP
AGAINST THE
ANTENNA CABLE
I
I
======
WEATHERPROOFING KIT
ISSUE DATE: 02-26-14
2 1/2"0 MAX.
TOOTHEAD CONNECTORS CONNECTOR
3/8"0x1 1/2" BARREL
S/S NUT
WASHERS CK
WASHER FLATS IM•I IM•I
1' MIN
1/4"
MIN
(SEE NOTE 3)
A
01/30/14
CABLE GROUND KIT
#6 AWG STRANDED COPPER GROUND
WIRE (GROUNDED TO GROUND BAR)
(SEE NOTE 1 & 2)
AF
CONNECTION OF CABLE GROUND KIT TO
mSTANDARD
ISSUED FOR 100% CONSTRUCTION
AF
1
m����I'`'-(2,72
CABLE
mCONNECTORCLEAR HEAT
NO1E$:
1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS
DIRECT GROUND WIRE DOWN TO GROUND BAR.
2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT WITH
TWO -HOLE LUG.
3, WEATHER PROOFING SHALL INCORPORATE PPC WEATHERPROOFING
TAPE KIT, COLD SHRINK SHALL NOT BE USED.
SHRINK
im=• I l TINNED COPPER • CLEAR
GROUNDING BAR HEAT
SHRINK
S/S FLAT WASHER
S/S BOLT (1 OF 2)
"DO NOT
DISCONNECT" TAG
ON ALL GROUND
BAR INTERCONNECTS
AND EQUALIZERS
#2 AWG STRANDED =11111 GROUND BAR NEAR
INSULATED BONDED TOP OF MONOPOLE,
TO TOWER STEEL TOWER OR WAVEGUIDE
LADDER.
OR MONOPOLE
22'x34' SCALE: NOT TO SCALE NOT USED
11"x17" SCALE: NOT TO SCALE
1
22'04* SCALE: NOT TO SCALE ANTENNA GROUND BAR
11" x17" SCALE: NOT TO SCALE
2
22'x34" SCALE: NOT TO SCALE CABLE GROUNDING
7"
11-x1SCALE: NOT TO SCALE
3
22"x34' SCALE: NOT TO SCALE
11"x17' SCALE: NOT TO SCALE 1NVO HOLE LUG
4
�'�
PUN 2 HOLE LUG SST "T" SPI ICS 1
STRANDED CU WIRE WITH GREEN. NOTER
600V, THHN/THWN INSULATION. SURFACERAIDEET NO -OX GREASEUANDANDT
/ BETWEEN LUG GROUND
SIZE AS SPECIFIED
BAR
GROUND LEADS TO NEW PIPE MOUNT, NEW
SPRINT ANTENNAS & NEW SPRINT RRU'S
LICENSURE:
GROUND BAR ON
ANTENNA TOWERCRO
f
SHEET NUMBER:
E-3
COAX CABLE
GROUND LEADS
T
j 61114,
1 BOLT PARALLEL UNNERSA
BOLTPARALLEL T +
\
PPE
LAMPS
O
00
O•
0000
o•
O O O(13
0 0 O2
0000
O
OCONNECTIONS.
J
EXISTING x T
HK.,O00OOOOO/TINNED GROUNDBAR &
5P11GE6 PJeEAGCLAMPH2
Cp
UNNFRSAL
a
PIPE CLAMPS BOLT
)
GRAD
TWO -HOLE LUG, BOLTED TO
GROUND BAR USING 3/8"-16 x 1
1/4"STAINLESS STEEL HEX HEAD
BOLTS AND HARDWARE.
75/1,25 ROD CLAMP
EXOTHERMIC WELD WITH #2 AWG SOLID TINNED
BARE CU WIRE OR STRANDED CU WIRE WITH
GREEN, 600V, THHN/THWN INSULATION TO MGB
22"x34' SCALE: NOT TO SCALE TYPICAL MECHANICAL CONNECTIONS
11"x17" SCALE: NOT TO SCALE
5
22"x34' SCALE: NOT TO SCALE ANTENNA GROUND BAR CONNECTIONS
11"x17" SCALE: NOT TO SCALE
6
#6 AWG GREEN STRANDED
CU GROUNDING CONDUCTOR
FROM RRU UNIT TO #2 AWG
GROUNDING CONDUCTOR
STRANDED CU WIRE WITH GREEN,
600V, THHN/THWN INSULATION. *PROVIDE NO -OX GREASE AT CONTACT
SIZE AS SPECIFIED
SURFACE BETWEEN LUG AND GROUND BAR
GROUND BAR ON
WALL, FLOOR OR ON
ANTENNA TOWER
—
—
Lr�fi
—
— ---
GROUND LEADS TO EACH
� ANTENNA GROUND BAR
COAX
GROUND BEADS \
THIN WALL C -TAP W/PINK
DYE INDEX (SEE NOTE)
/ O
O
—
O
O
0000000000000000000
0
QO
OO
0
Q
0
OO
,_,
/....
0
O O O O O O O O O O O O O
O O O O O O O O O O O O O
0 0 0 0 0 0 0 0 0 0 0 0 0
OO
O
0
OOOO
O
0
O
0
O
O/
& CNG GROUND BAR
E CONNECTIONS
011/°'/
.1
#2 AWG STRANDED CU
GROUNDING CONDUCTOR
NOTE:
CONTRACTOR TO SURROUND COMPLETED
CONNECTION W/ WEATHER PROOFING TAPE TO
ENSURE WEATHER PROOF CONNECTION.
u
TWO -HOLE LUG, BOLTED TO
GROUND BAR USING 3/8"-16 x 1
1/4"STAINLESS STEEL HEX HEAD
BOLTS AND HARDWARE.
EXOTHERMIC WELD WITH #2 AWG SOUD TINNED
BARE CU WIRE OR STRANDED CU WIRE WITH GREEN,
STRUCTURE, TBUILDING,WN INSULATION TO ANTENNA ij
RING GROUND OR MGB
0,,ge
11
•• GROUND BARS AT BOTTOM
POLES
OF TOWERSUSE X THEMORMIC
SHALL USE EXOTHERMIC
CONNECTION.
22"04" SCALE: NOT TO SCALE NOT USED
11"x17" SCALE: NOT TO SCALE
7
22'x34" SCALE: NOT TO SCALE C -TAP CONNECTION
11"x17• SCALE: NOT TO SCALE
8
22x34" SCALE: NOT TO SCALE TOWER MASTER GROUND BAR CONNECTIONS
11"x17" SCALE: NOT TO SCALE
9
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint)
CCYEN
-1-
PACIFIC 505 2NDCOM AVE. SURE 129, Lac
10
SEATTLE, WA 95104
PROJECT INFORMATION:
TUKWILA
SE03XC408 / CCI 880338
12400 51ST PL. S
TUKWILA, WA 98178
KING COUNTY
ISSUE DATE: 02-26-14
ISSUED FOR: CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INRIALS
A
01/30/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/26/14
ISSUED FOR 100% CONSTRUCTION
AF
•NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE:
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-18-15
0.00.3
somom
SHEET TITLE
GROUNDING DETAILS
SHEET NUMBER:
E-3
REVISION:
0
SE03XC408