Loading...
HomeMy WebLinkAboutPermit PL14-0026 - AMANDA HOFFMAN / SMARTLINK - SPRINT TYPE I WIRELESS TELECOMMUNICATIONS FACILITIES PERMITThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. PL14-0026 SPRINT TYPE 1 WIRELESS 10825 E MARGINAL WAY S RECORDSDIGITAL D-) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Coda Exemption, � � � I3ri6f Explanatory 6escrlofion, Sfatutte/Ruilo The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. 14 DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. Personal Information — Redactions contain information used to prove RCW DR3 Driver's License. — RCW identity, age, residential address, social security 42.56.230 (7a 42.56.230 number or other personal information required to & c) (7a & c) apply for a driver's license or identicard. Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney -Client Privilege — disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); DR4 RCW 5.60.060(2)(a); RCW which protects attorney-client privileged RCW 42.56.070(1) communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. SPRINT SEO3XC4O9-SR-599 10825 EAST MARGINAL WAY S PL14-0026 L14-0038 WIRELESS TYPE 1 r City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director August 29, 2014 NOTICE OF DECISION TO: Amanda Hoffman Smartlink LLC 14432 SE Eastgate Way, Ste. 260 Bellevue, WA 98007 Paul Nicewonger 901 W Evergreen Blvd. Vancouver, WA 98660 This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit approval. Project File Number: Applicant: Type of Permit Applied for: Project Description: Location: Associated Files: Comprehensive Plan Designation/Zoning District: I. PROJECT INFORMATION L14-0038, PL14-0026 Amanda Hoffman, Smartlink LLC, obo Sprint Type 1 Wireless Telecommunications Facilities Permit Approval of a Type I Wireless Communication Facilities Permit in order to install 3 panel antennas and 3 Remote Radio Units, relocate 3 existing antennas and 3 Remote Radio Units, and remove 1 existing antenna platform from an existing 63' roof -mounted monopole. No ground disturbance or expansion of the existing compound is proposed. Parcel Number: 0323049198. The site address is 10825 E Marginal Way S, Tukwila, WA 98168. N/A Manufacturing Industrial Center/Heavy Industrial (MIC/H) II. DECISION SEPA Determination: The City SEPA Responsible Official has previously determined that this application does not require a SEPA threshold determination because it is categorically exempt. MB Page 1 of 3 W:\Users\Max\Wireless Facilities\L14-0038\L14-0038 NOD.docx 08/29/2014 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 Decision on Substantive Permit: The City Community Development Department has determined that the application for a Type 1 Wireless Communications Facility does comply with applicable City and state code requirements and has approved that application without conditions. III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code § 18.104.010. Other land use applications related to this project may still be pending. No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to challenge either the conditions which were imposed by the MDNS decision or the failure of the Department to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing Examiner. A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in King County Superior Court from the Hearing Examiner's decision. IV. PROCEDURES AND TIME FOR APPEALING In order to appeal the Community Development Director decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14 days of the issuance of this decision, that is by September 12, 2014. The requirements for such appeals are set forth in Tukwila Municipal Code ch. 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing party's behalf. 3. A statement identifying the decision being appealed and the alleged errors in the decision, including any specific challenge to an MDNS. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. 5. Appeal fee of $541 plus retainer. V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the Hearing Examiner based on the information presented to the Community Development Director, who made the original decision. No new evidence or testimony will be permitted during the appeal hearing. MB Page 2 of 3 08/29/2014 Parties will be allowed to present oral argument based on the information presented to the Community Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is the City's final decision. Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW ch. 36.70C. An appeal challenging a DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the subject property. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Max Baker, who may be contacted at 206-431-3662 or via email at max.baker@tukwilawa.gov for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. Department of Community Development City of Tukwila MB Page 3 of 3 08/29/2014 &hi at Ju:F,'u[�iea Department Of Community Development AFFIDAVIT OF DISTRIBUTION I, _Teri Svedahl , HEREBY DECLARE THAT: Associated File Number (s): L14-0038 Notice of Application X Notice of Decision / Notice of Public Hearing Notice of Public Meeting Determination of Non- Significance Mitigated Determination of Non - Significance Determination of Significance & Scoping Notice Short Subdivision Agenda Notice of Application for Shoreline Mgmt Permit Shoreline Mgmt Permit Board of Appeals Agenda Packet Board of Adjustment Agenda Packet Official Notice Notice of Action Other: Was mailed to each of the addresses listed/attached on this _2 day of September 2014 Project Name: Sprint SE03XC409-SR-599 Project Number: PL14-0026 Associated File Number (s): L14-0038 Mailing requested by: Max Baker Mailer's signature: / W:\USERS\TERI\TEMPLATES-FORMS\AFFIDAVIT OF DISTRIBUTION.DOC City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director STAFF REPORT TO THE DIRECTOR PREPARED August 29, 2014 NOTIFICATION: Notification is not required for a Type I land use application. FILE NUMBER: L14-0038, PL14-0026 APPLICANT: Amanda Hoffman, Smartlink LLC, obo Sprint PROPERTY OWNER: Paul Nicewonger REQUEST: Approval of a Type I Wireless Telecommunication Facilities Permit to upgrade existing antennas, associated cabling on an existing wireless facilities tower. LOCATION: Tax Lot NO: 0323049198. This tower is located at 10825 E Marginal Way S. ASSOCIATED PERMITS: Electrical permits issued through the City of Tukwila will be required for service alteration for any other electrical service work this is anticipated but not noted on the plans, per article 85.13 (B), Washington electrical code. Building permit is not required for scope of work stated on the submitted plans. SEPA DETERMINATION: Exempt COMPREHENSIVE PLAN DESIGNATION: Manufacturing Industrial Center/Heavy Industrial (MIC/H) ZONE DESIGNATION: Manufacturing Industrial Center/Heavy Industrial (MIC/H) STAFF: Max Baker, Planning Intern ATTACHMENTS: Project Plans for Permit L14-0038 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 FINDINGS Vicinity/Site Information Project Description The applicant is requesting approval of a Type I Wireless Telecommunication Facilities [WCF] Permit to add equipment on an existing tower at 10825 E Marginal Way S. The work includes: • Installation of 3 panel antennas • Installation of 3 Remote Radio Units • Relocation of 3 existing antennas • Relocation of 3 Remote Radio Units • Removal of 1 existing antenna platform The existing cellular tower is 63' feet tall at its highest point, mounted upon a 30' tall building. Existing Development The monopole is installed atop a two-story office building. Surrounding Land Uses The property and the surrounding parcels are zoned MIC/H. The to the north is a Chevron gas station, located at the intersection of E Marginal Way S, Pacific Hwy S, and S Boeing Access Rd. To the west across Pacific Hwy S is the Duwamish River. BACKGROUND In 2006, the City adopted a Wireless Facilities Chapter (TMC 18.71) to the Zoning Code. The chapter provides specific location and design requirements for the placement of WCF within the City of Tukwila. The WCF being modified was originally approved by the City in 1996 (L96-0062) through a conditional use permit. Location Selection Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co -locations and utilizing existing structures are favored over the development of new standalone WCF within the City. TABLE A Type of Permit Required, Based on Type of Wireless Communication Facility ZONING (1) TYPE OF FACILITY RESIDENTIAL COMMERCIAL INDUSTRIAL Transmission Tower co -location Type 1 Type 1 Type 1 Adding antennas to an existing tower Type 1(2) Type 1(2) Type 1(2) Utility pole co -location Type 2 Type 2 Type 2 Concealed building attached Type 2(3) Type 2(3) Type 2(3) Non -concealed building attached Type 2 Type 2 Type 1 New tower or waiver request Type 4 Type 4 Type 4 (1) SM Zoning for any private/public property or right-of-way Residential — LDR, MDR, or HDR Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS Industrial - LI, HI, MIC/L, or MIC/H Page 2 of 5 08/29/2014 (2) Provided the height of the tower does not increase and the square footage of the enclosure area does not increase. (3) An applicant may request to install a non -concealed building attached facility, under TMC Section 18.58.150. The applicant is adding additional antennas to an existing tower. This decision does not require the use of any new facilities for placement of the new antennas. Design Standards The City provides specific design standards for the placement of WCF within the City of Tukwila. The table below indicates if the applicant's proposal complies with required standards. Table 1 (See TMC 18.58.070 for further details) General Requirements Project does comply Project does not comply Not Applicab le Notes 1. Generators or other devices which will create noise must comply with TMC 8.22 regarding noise. X The applicant has not proposed a new generator. 2.Business License Requirement X Sprint has applied for a business license (0995760) 3. Only safety signage must be placed on the WCF. X The applicant does not propose any signage. 4. Accommodations for parking for maintenance personal must be provided. X Parking is not affected by this modification. 5. Towers shall either maintain a galvanized steel finish or be painted a neutral color so as to reduce its visual obtrusiveness. X No change to the existing tower is proposed. 6. The design of all buildings and ancillary structures shall use materials, colors, textures, screening, and landscaping that will blend the tower facilities to the natural setting and built environment. X No new buildings or structures are proposed. 7. Antennas shall have the same color scheme as the structure they are located on. X The antennas will be painted to match the existing color scheme of the tower and antennas. 8. WCF poles and towers shall only have safety lights if required by a government agency. X No lighting is proposed. 9. No advertising is permitted on WCF X No advertising is proposed. 10. Each service provider shall be limited to an equipment enclosure of 360 square feet. X No change to the existing equipment enclosure is proposed. SM Page 3 of 5 08/29/2014 Table 2 (See TMC 18.58.090 for additional information) Adding Antennas to Existing WCF Tower- Specific Development Standards Project does comply Project does not comply Not Applicab le Notes 1. When adding antennas to existing WCF towers, height must not exceed what was approved under the original application to construct the tower. X No change to the previously approved tower height of 63' is proposed. 2. Antennas shall be painted to match the color scheme of tower. X Exposed antennas and ancillary equipment will be painted to match the existing tower color. 3. There is no limit on the number of antennas that may be located on an existing tower. X 4. Feed lines and coaxial cables shall be located within the tower. Those exposed shall be painted to match tower. X Cables shall be routed within the tower. Exposed cables will be painted to match site conditions. 5. A new cabinet shall be located within the equipment enclosure that was approved as part of the original application, or it will require a Type 2 decision. X No new cabinets are to be installed. 6. Setbacks shall not apply when an applicant installs new antennas on an existing tower and uses an existing equipment enclosure. If the equipment enclosure is increased, it must meet setbacks. X There is no change to the existing equipment enclosure. SM CONCLUSIONS 1. The proposed modifications to the existing antenna will not significantly alter the conditions that currently exist and will not be materially detrimental to the public welfare or injurious to property or improvements in the vicinity. 2. As demonstrated in Tables 1 and 2, the project meets all applicable development standards for a Type 1 WCF. 3. The proposed modifications will not alter the surrounding land uses in terms of traffic and pedestrian circulation, building or site design. Page 4 of 5 08/29/2014 4. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy Plan. RECOMMENDATIONS The recommendation to the Director of Community Development is to approve this application for a Type I Wireless Telecommunication Facility permit as applied for by Crown Castle for Sprint without conditions. INFORMATIONAL ITEMS A City of Tukwila electrical permit is required for service alteration. Please note that the installation of an emergency power disconnect switch is required for fire department use. Contact Don Tomaso at 206-971-8723 to get more information about permit requirements for the power disconnect switch. SM Page 5 of 5 08/29/2014 0400 City of Tukwila Department of Community Development File Number L14-0038 LAND USE PERMIT ROUTING FORM TO: i,Building Planning Public Works Fire Dept. Police Dept. U Parks/Rec Project: Sprint Type 1 Wirless Facility Address: 10825 East Marginal Way S Date transmitted: 6/19/2014 Response requested by: 6/26/2014 Staff coordinator: Max Baker Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability 1:o administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60 -day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) ///4 - Plan check date: .... Z� /5 Comments prepared by: Update date: l/ Max Baker From: Max Baker Sent: Thursday, June 19, 2014 3:37 PM To: amanda.hoffman@smartlinkllc.com Subject: Sprint Business License, 10825 E Marginal Way S Hi Amanda, I am currently reviewing your Wireless Facilities Permit application, L14-0038. I have not found a business license for the wireless tower at the address, and under our current code it is required for a wireless facility to have a license connected to its location. To learn more about obtaining a business license, please contact the Tukwila Finance Department at 206-433-1835. They will be able to answer any questions about the process for application. Sincerely, Maxwell Baker Planning Intern City of Tukwila Max.Baker@tukwilawa.gov (206) 431-3662 The City of opportunity, the community of choice. AS OF iraa ORIGINAL LEASE OOcwENT ~MAILABLE 'RIS DOCUMENT ISA COPY' Site I.O. 7 C ilk'- GLS y QS Site Name %t40p.47,0vf,—e,Z • PCS SITE AGREEMENT 1. Premises and Use O.+•ner leases to MafarCo. L. P . a Delaware limited oartnersnip ( ALP•), C': 2 Sprint Telecommunications Venture, the site described below. ,Cdress - 'ti-S - /?"r,l: ;,:'(1t. /J/ l: • {Cheek app:apnate oox(es ; ^^ Real properly corsistr-r cf apbroximatelysquare feet o' land: Building interior space consisting of approximately square feet: la Building exterior space for attachment of antennas; O Building exterior space for placement of base station equipment; O Tower antenna space; la,Space required for cable runs to Connect PCS equipment and antennas, in the location(s) ('Site) shown on Exhib:t A. together with a nonexclusive easement for reasonable access there;: and to the appropriate. in the discretion of MLP, source of electric and telephone facilities. The Site will be used by MLP for the purpose of installing, removing. replacing. maintaining and operating. at its expense, a personal communications service system facility ('PCS'). including, without limitation, related antenna equipment and fixtures. MLP will use the Site in a manner which will not unreasonably disturb the occupancy of Owner's other tenants. 2. Term. The term or this Agreement (the 'Initial Term') is five years, Commencing on the date ('Commencement Date) MLP signs this Agreement. This Agreement will be automatically renewed for four additional terms (each a 'Renewal Terme) of five years each. unless MLP provides Owner notice of intention not to renew not less than 90 days prior to the expiration of the Initial Term or any Renewal Term. 3. Rent. Sinycifol Site Address 0 r - , j .e6,,, .+ GU . $o. S t-Afr li v - f Y 11. Termination. MLP may terminate this Agreement at any notice to Owner without further liability i1 MLP does not obtain all perlimemitsby or other approvals (collectively, 'approval') required from any governmental aulho'its •or any easements required from any third party 10 operate the PCS system, ;.: it any such approval is canceler. expires or is witho:awn Or terminated, or Y Owner fails to have proper ownership of the Site or authority 1e enter into thr• Agreement. or if MIP, for any other reason, in its sole discretion, determines that it will be unable to use the Site for its intended purpose. Upon termination. all prepaid rent shall be retained by Owner. 12. Default. If either party is in default under This Agreement for a perioc of (a) 10 days following receipt of notice from the non -defaulting party wit: - respect to a default which may be cured solely by the payment of money, c: (b) 30 days following receipt of notice from the nen-defaulting party NYC -- respect to a default which may not be cured solely by the payment of money then, in either event. the non -defaulting party may pursue any remedies available to it againsl the defaulting party under applicable law, including, but not limited to, the right to terminate this Agreement. If the non -monetary default may not reasonably be cured within a 30 day period, this Agreemen: may not be terminated if the defaulting party commences action to cure the default within such 30 day period and proceeds with due diligence to fully cure the default. 13, Indemnity. Owner and MLP each indemnifies the other against and holds the other harmless from any and al costs (including reasonable attorney: fees) and claims of liability or loss which arise out of the use andro: occupancy Of the Site by the indemnifying party. This indemnity does 'not apply to any claims arising from the sole negligence or intentional misppnduc. • of the indemnified party. 14. Hazardous Substances. Owner represents that it has no knowledge c• any substance, chemical or waste (collectively. 'substance') on the Site that is identified as hazardous. toxic or dangerous in any applicable federal, state o: total law or regulation. MLP shall not introduce or use any such substance or the Site in violation of any applicable law. 15. Miscellaneous. (a) This Agreement applies to and binds the heirs successors, executors, administrator's and assigns of the parties to this greement; (b) This Agreement is governed by the laws of the State in whirl the Site - is located; (c) If requested by MLP, Owner agrees promptly lc execute and deliver to MLP a recordable Memorandum of this Agreement it the form of Exhibit B; (d) This Agreement (including the Exhibits) constitute: the entire agreement between the parties and supersedes all prior written anc verbal agreements, representations, promises or understandings between tht parties. Any amendments to this Agreement must be in writing and execute( by both parties; (e) 1f any 'provision of this. Agreement is invalid o unenforceable with respect to any party the remainder of this Agreement c the application of such provision 10 persons other than those as to whom it is held invalid or unenforceable, wilt not be affected and each provision of this Agreement will be valid and enforceable to the fullest extent permitted by lax and (1) The prevailing party in any action or proceeding in court or mutuatl agreed upon arbitration proceeding to enforce the terms of this Agreement entitled to receive its reasonable attorneys' fees and other reasonabl. enforcement costs and 4. Title and Quiet Possession. Owner represents and agrees (a) that d is the Owner of the Site; (b) that it has the right to enter into this Agreement: (c) that the person signing this Agreement has the authority to sign; (d) that MLP is entitled to access to the Site at al times and to the quiet possession of the Site throughout the Initial Term and each Renewal Term so long as MLP is not in default beyond the expiration of any cure period; and (e) that Owner shall not have unsupervised access to the Site or to the PCS equipment. 5. Assignment/Subletting. MLP will not assign or transfer this Agreement or subtet all or any portion of the Site without the prior written consent of Owner, which Consent will not be unreasonably withheld, delayed or conditioned; provided, however, MLP may assign or sublet without Owner's prior written Consent to any party controlling, controlled by or under common control with MLP or 10 any party which acquires substantially all of the assets of MLP: 6. Notices. All notices must be in writing and are effective when deposited in the U.S. mail. certified and postage prepaid, or when sent via ovemight delivery. to the address se: forth below. or as otherwise provided by law. 7. Improvements. MLP may. at its expense, make such improvements on'the Site as it deems necessary from time to time for the operation of a transmitter site for wireless voice anc data communications. Owner agrees to cooperate with MLP with respect to obtaining any required zoning approvals for the Site and such improvements. Upon termination or expiration of this Agreement. MLP may remove its equipment and improvements and will restore the Site to the condition existing on the Commencement pate, except for ordinary wear and tear. E. Compliance with Laws Owner represents that Owners propery (including the Site). and ah improvements loca:ed thereon, are is suostanlial compliance with buitdine, Irfersafe:l•. CiSabiiity anc other laws. woes ant: regulations of applicaDie gove:nmentat autno:ities. MLP will substantially comply with all applicable taws relating to its possession and use of the Site. 9. Interference. MLP wilt resolve technical interference problems with other equipment located at the Site on the Commencement Date or any equipment that becomes attached to the Site at any future date when MLP desires to add additional equipment to the Srte. Likewise. Owner will not permit the installation Of any future equipment which results in technical interference problems with MLP's then existing equipment O. Utilities. Owner represents That utilities adequate for MLP's use of the Site are available. MLP wilt pay for all utilities used by it at the Site Owner will cooperate with MLP in MIP's efforts to obtain utilities from any location tl)R GlyrWWncaslt LS!1Collt•icing-uti;ity .. •. •' penses from the non -prevailing party. The following Exhib are attach to and made a part of 11 Agreement: Exhibit . B.1, B 2 tai uJ OWNER: By: Paul NicewonRer,as trustee Its: S S.fTax t.o.: '901' k'.. Evergreen Blvd Vancouver, WA 96660 .4AJz Address Gale O. L,P , a Delaware !united partnership may: --- Vis: Gi*. - >_ r' :`",r Gift 1 S -d' aJ.i Date- Continuation ate Continuation of owner signatures lollows immediately ORIGINAL ddrest aelielr:4 e t.* c5evai Site Name 111/G4. Llio,v6-`,2 3tQ6 Site situated in the City of S E/f7rt. e described as Sketch of Site: Transformer Possible Equipment Site NORTH Owner Initials MLP Initials XMTR Ground Location EXHIBIT A PCS Site Agreement Site Description . County of K/ Ai 85' Site I. D.D,9— - . . State of Le/67SW. commonly ti 16' High. 12' x 12' J -Frame Tower. ❑(3.5' x 3') Roof Access Actual Position May Depend On Rooftop Load Requirements. Roof Mount Frame To Be Camouflaged With Fiber Class Panels. 100' Note: Owner agrees that MLP may. al MLP s option. 'supplement This Exhibit with an exhibit selling forth the legal description of the propeny on which the Site llocated and/or an as -built drawing depicting the Site. lip Legal description follows immediately Dale:12/27,95 ww Version •1.0 ORIGIN.A Sea:: Site Narne Nicewonger Bldg Legal Description of Property: EXHIBIT A PCS Site Agreement Site Description . Site 1. O.SETA_uO_nr; The north 90 feet of the following described property: That portion of the southwest Section 3, Township 23 North, Washington, and of Government North, Range 4 East, W.M., in follows: quarter of the southwest quarter of Range 4 East, W.M., in King County, Lot 10, in Section 4, Township 23 King County, Washington, described as Beginning at the southwest corner of said Section 3; thence north 60 feet; thence .south 88°51'20" east 530.46 feet to the westerly line of East Marginal Way; thence north 17°20'00" west along said westerly line 931.36 feet to the TRUE POINT OF BEGINNING; thence continue along said westerly line north 17°20'00" west 161.02 .feet to the southerly line of Tract deeded to Cesare Traverso by deed recorded under Recording Number 2676396; thence along said south line south 84°43'30" west 219.51 feet to the east line of State Road No. 1; thence along said east line south 18°17'00" west 289.18 feet; thence south 71°02'30" east 156.41 feet; thence north 86°14'30" east 107.81 feet; thence north 10°20'30" east 169.51 feet; thence north 76°09'30" east 74.29 feet to the TRUE,POINT OF BEGINNING; EXCEPT the east 12 feet thereof conveyed to King County by Deed recorded under King County .Recording Number 88042120368. Site Name AbGe a./O.t/6`E0( A.496" EXHIBIT B PCS Site Agreement Site I. D. $0779—MO 'Os—, Memorandum of PCS Site Agreement This memorandum evidences that a lease was made and entered info by written PCS Site Agreement dated _2j_____23 / 96 19_ , between Paul N i c e w o n fte r, as trustee ("Owner) and MajorCo, L.P.. a Delaware limited partnership ('MLP'), d/b/a Sprint Telecommunications Venture. the terms and conditions of which are incorporated herein by reference. Such Agreement provides in pa /08177S-4 lJ9.�,e6 /A/#9 4% o X / �v t— State of attached hereto, with grant of easement for five (5) years commencing on f}/�- by MLP. • that Owner leases to MLP a certain (-Site) located at City of E,97-/-z-County or 'WA —4/4i. , within the property of Owner which is described in Exhibit 8.1 unrestricted ghts of access thereto and to electric and telephone facilities for a term of . ' , 192y, which term is subject to four (4) additional five (5) year extension periods site IN WITNESS WHEREOF, the parties have executed this Memorandum as of the day and year first above written. By: Name: Title: O W w/ it I _ Address: "OWNER" Paul Nicewonger ,as trustee "MLP" MajorCo, L.P..a Delaware limited partnership By: e.1.. Name: %' Title: b /rec. ,ge4/?4 L. /11 901 W_ RvPrg rPPn R1 Ind . Address: )IXk) Nr 33ot Ply, 314- cOt Vancouver, WA 98660 AeilGVut, jr.* 9C-vO4 0 Continuation of owner signatures follows immediately Owner Initials MLP Initials M YK_ F7arRAMg.74fa version 2.0 Site Name Nicewonger Bidg.T) Exhibit B.1 Site I. D. SETA -009=05 Memorandum of PCS Site Agreement: Lfgal Description of Property Legal Description of Property! The north 90 feet of the following described property: That portion of the southwest Section 3, Township.23 North, Washington, and of Government North, Range 4 East, W.M., in follows: quarter of the southwest quarter of Range 4 East, W.M., in King County, Lot 10, in Section .4, Township 23 King County, Washington, described as Beginning at the southwest corner of said Section 3; thence north 60 feet; thence south 88°51'20". east 530.46 feet to the.westerly line of.East Marginal, Way; thence north 17°20'00",west along said westerly line 931.36 feet to, the TRUE POINT OF BEGINNING; thence continue along said westerly line north 17°20'00" west 161.02 feet to the southerly line of Tract deeded to Cesare Traverso by deed recorded under Recording Number 2676396; thence along said south line south 84°43'30" west 219.51 feet to the east line of State Road.No. 1; thence along said east line south 18°17'00".west 289.18 feet; then south 71°02'30" east 156.41 feet; thence north 86°14'30" east 107.81 feet; thence north 10°20'30" east 169.51 feet; thence north 76°09'30" east 74.29 feet to the TRUE POINT OF BEGINNING; EXCEPT the east 12 feetthereof conveyed to King County by Deed recorded under King County Recording Number 88042120368. Date 3/4196 Version 2.1 ww Site Name fV.G�lc�2n►ii - ��G.r Exhibit 13.2 Site 1. D.5ET79-009'O� Memorandum of PCS Site Agreement: Notary of Signatures INDIVIDUAL - SINGLE +° STATE OF Washington COUNTY OF Clark I certify that I know or have satisfactory evidence that Paul Wioewnngar is the person who appeared before me, and said person acknowledged that said person signed this instrument and acknowledged it to be said person's free and voluntary act for the uses and purposes mentioned in the instrument. Dated this 23rd day of February (AFFIX NOTARIAL SEAL) My commission LINDA J. BROSIUS NOTARY PUBLIC STATE OF WASHINGTON txpiresCOMMISStON EXPIRES DECEMBER 18, 1997 'STATE OF r c Vat* COUNTY OF , 199_6 Anda. 4- PJn,L:Qiun (OFFICIAL NOTARiSIGNATURE) • NOTARY PUBLIC -STATE OF .Washir1Ct0n (PRINTED. TYPED OR STAMPED NAME OF NOTARY) COMMISSION NUMBER: December 18. 1,497 I certify that I know or have satisfactory evidence that -(M4 is the person who appeared before me, and said person acknowledged that said person signed this instrument, on'oath stated that said person was authorized to execute the instrument and acknowledged it as the authorized employee of MajorCo, L.P., a Delaware limited partnership. to be the -free and v• •f such limited partnership for the uses and purposes mentioned in the instrument. f (1jIIPLI My commission expires. { !fel 199Ci (OFFICIAL NOTARY SIGNATU NOTARY PUBLIC—STATE OF (PRINTED, TYPED OR STAMPED NAME OF NOTARY) COMMISSION NUMBER: • Version 2.0 (ln)(-'',i A L. Semite smartlink Project Description Date: May 16, 2014 To: City of Tukwila 6300 Southcenter Blvd., #100 Tukwila, WA 98188 From: Amanda Hoffman RE: Sprint 2.5-SE03XC409-SR-599 Type I WCF Application Sprint is proposing to alter the previously approved (L96-0062) wireless communication facility located at 10825 E Marginal Way Ave., S. by installing 1 new panel antenna per sector (total of 3) and 1 new Remote Radio Unit per sector (total of 3) on an existing monopole. 18.58.090 Adding Antennas to Existing WCF Tower -Specific Development Standards. 1. Height — The height must not exceed what was approved under the original application to construct the tower. If the height shall exceed what was originally approved, approval as a Type 2 decision is required for any height which will be less than the maximum height of the zone. Response: The proposal does not include a height increase. The proposed antennas will not exceed what was approved under the original application (L96-0062). 2. Antenna aesthetics —Antennas shall be painted to match the color scheme of the tower. Response: The proposal includes the antennas to be painted to match the existing color scheme of the tower and antennas. 3. Antenna intensity — There is no limit on the number of antennas that may be located on an existing tower. Response: The proposal includes an addition of 3 panel antennas and 3 remote radio units on an existing tower. 4. Feed lines and coaxial cables — Feed lines and coaxial cables shall be located within the tower. Any exposed feed lines or coaxial cables (such as when extended out of the tower to connect to the antennas) must be painted to match the tower. Response: The applicant proposes to be in compliance with the above criteria. 5. Cabinet equipment — A new cabinet shall be located within the equipment enclosure that was approved as part of the original application. If the applicant wishes to expand the equipment smartlink enclosure from what was approved by the City or County under the previous application, the applicant shall seek a wireless communication facility (Type 2) application for only the equipment enclosure increase. Response: No new equipment cabinets are proposed with this application. The existing equipment is contained in a secure room. 6. Setbacks — Setbacks shall not apply when an applicant installs new antennas on an existing tower and uses an existing equipment enclosure. If the equipment enclosure is increased, it must meet setbacks. Response: The application includes installation of new antennas on an existing tower and therefore the setback criteria does not apply. No new equipment enclosures are proposed. If you have any questions and/or concerns about the enclosed materials, please feel free to contact me at by phone at (503) 476-4883, or via email amanda.hoffman@smartlinklIc.com. Thank you, Amanda Hoffman CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX: (206) 431-3665 E-mail: planningna,TukwilaWA.gov 'See Attached Lease agreement" #7 on page 1' outlined in red AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY STATE OF WASHINGTON Ss COUNTY OF KING The undersigned being duly sworn and upon oath states as follows: 1. I am the current owner of the property which is the subject of this application. 2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my knowledge. 3. The application is being submitted with my knowledge and consent. 4. Owner grants the City, its employees, agents, engineers, contractors or other representatives the right to enter upon Owner's real property, located at 10825 E Marginal Way S for the purpose of application review, for the limited time necessary to complete that purpose. 5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City. 6. Non -responsiveness to a City information request for ninety (90) or more days, shall be cause to cancel the application(s) without refund of fees. REcENED mg 29 AM coMMUN11 EXECUTED at (city), (state), on , 20 (Print Name) (Address) (Phone Number) (Signature) On this day personally appeared before me to me known to be the individual who executed the foregoing instrument and acknowledged that he/she signed the same as his/her voluntary act and deed for the uses and purposes mentioned therein. SUBSCRIBED AND SWORN TO BEFORE ME ON THIS DAY OF , 20 NOTARY PUBLIC in and for the State of Washington residing at My Commission expires on H:\Land Use Applications in PDF\Wireless Communication Facility-]an201 l.doc CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX: (206) 431-3665 E-mail: planning@TukwilaWA.gov WIRELESS TELE- COMMUNICATION FACILITIES INFORMATION City of Tukwila governs the placement of wireless telecommunication facilities under Tukwila Municipal Code (TMC) 18.58. The review process for new antennas and facilities is based on the type of facility and the location of the facility. The City's goal is to streamline the placement of desirable facilities that are located on existing cell towers, within commercial and industrial zones, and on electrical transmission towers. TABLE A Type of Permit Required, Based on Type of Wireless Communication Facility Zoning° Type of Facility Residential Commercial Industrial Transmission tower co -location Type 1 Type 1 Type 1 Adding antennas to an existing tower X Type 1(2) Type 1(2) X Type 1(2) Utility pole co -location Type 2 Type 2 Type 2 Concealed building attached Type 2(3) Type 2(3) Type 1 Non -concealed building attached Type 2 Type 2 Type 1 New tower or waiver request Type 3 Type 3 Type 3 (2) (3) Zoning for any private/public property or right-of-way: Residential — LDR, MDR, or HDR. Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS. Industrial — LI, HI, MIC/L, or MIC/H. Provided the height of the tower does not increase and the square footage of the enclosure area does not increase. An applicant may request to install a non -concealed building attached facility, under TMC Section 18.58.150. H:V.and Use Applications in PDF \W reless Communication Facility-Jan2011.doc COMPLETE APPLICATION CHECKLIST The materials listed below must be submitted with your application unless specifically waived in writing the Department of Community Development. Please contact each Department if you feel that certain items are not applicable to your project and should be waived. Application review will not begin until it is determined to be complete. ADDITIONAL MATERIALS MAY BE REQUIRED. The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require additional information as needed to establish consistency with development standards. City staff are available to answer questions about application materials at 206-431-3670 (Department of Community Development) and 206-433-0179 (Department of Public Works). Check items submitted with application Information Required. May be waived in unusual cases, upon approval of both Public Works and Planning APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities. ✓ 1. Application Checklist (1 copy) indicating items submitted with application. ✓ 2. Completed Application Form and drawings (5 copies). ✓ 3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site map, architectural elevations, method of attachment, proposed screening, location of proposed antennas, and all other information which accurately depicts the proposed project. Minimum size is 8 1/2" x 11". Plans shall be no greater than 24" x 36". ✓ 4. Application Fee: See Land Use Fee Schedule. ✓ 5. Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property (1 copy attached). n/a 6. SEPA Environmental Checklist. SEPA is not required when the facility: i) Is a microcell and is to be attached to an exiting structure that is not a residence or school and does not contain a residence or a school; ii) Includes personal wireless antennas, other than a microcell, and is to be attached to an existing structure (that may be an existing tower) that is not a residence or school and does not contain a residence or school, and the existing structure to which it is to be attached is located in a commercial, industrial, manufacturing, forest or agriculture zone; or iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a commercial, industrial, manufacturing, forest, or agricultural zone. x 7. A letter from the applicant describing the proposed project and describing compliance with the City's Code requirements. n/a 8. Sensitive Area studies and proposed mitigation (if required). n/a 9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating compliance with TMC Chapter 8.22, "Noise". If the application requires a Type 2 review these additional items are needed: 10. Four sets of photo simulations that depict the existing and proposed view of the proposed facility; 11. Materials board for the screening material; 12. Landscaping plan; 13. Letter from a radio frequency engineer that demonstrates that the facility meets Federal requirements for allowed emissions; 14. If the facility is located within a residential zone, a report from a radio frequency engineer explaining the need for the proposed wireless communication facility at that location. Additionally, the applicant shall provide detailed discussion on why the wireless communication facility cannot be located within a commercial or industrial zone. H:\Land Use Applications in PDF \W reless Communication Facility-Jan201 l.doc Check items submitted with application Information Required. May be waived in unusual cases, upon approval of both Public Works and Planning If the application requires a Type 3 review these additional items are needed: 15. A narrative responding to the criteria at TMC Section 18.58.060. 16. The radio frequency engineer report shall include a discussion of the information required under TMC Section 18.58.070. The report shall also explain why a tower must be used instead of any of the other location options outlined in Table A. 17. Engineering Plans for the proposed tower. 18. A vicinity map depicting the proposed extent of the service area. 19. A graphic simulation showing the appearance of the proposed tower and ancillary structures and ancillary facilities from five points within the impacted vicinity. Such points are to be mutually agreed upon by the Director of DCD and applicant. All plans and photo simulations shall include the maximum build -out of the proposed facility. 20. Evidence of compliance with Federal Aviation Administration (FAA) standards for height and lighting and certificates of compliance from all affected agencies. 21. Evidence that the tower has been designed to meet the minimum structural standards for wireless communication facilities for a minimum of three providers of voice, video or data transmission services, including the applicant, and including a description of the number and types of antennas the tower can accommodate. PUBLIC NOTICE MATERIALS: 22. Payment of a $365 notice board fee to FastSigns Tukwila OR provide a 4' x 4' public notice board on site within 14 days of the Department determining that a complete application has been received (see Public Notice Sign Specifications Handout). 23. Pay the fee as established by the Land Use Fee Schedule for generating mailing labels; OR provide an excel spreadsheet of mailing labels for all property owners and tenants (residents and businesses) within 500 feet of the subject property. Each unit in multiple family buildings e.g. apartments, condos, trailer parks --must be included. Once your project is assigned to a planner, you will be required to provide an electronic copy of the mailing label spreadsheet in the following format: Name, Street Address, City St Zip, with each of these fields as an individual column: Name Street Address City, St, Zip Mr. Smith 1234 Park Ave S Tukwila WA 98188 PLEASE NOTE: Regardless of whether you pay the City to generate the mailing labels or you provide them, there is an additional fee for postage and material as listed under Public Notice Mailing Fee on the Land Use Fee Schedule. Payment of this fee is due prior to issuance of the decision and you will receive a separate bill for this fee. 24. If providing own labels, include King County Assessor's map(s) which shows the location of each property within 500 ft. of the subject lot. H:\Land Use Applications in PDF\Wireless Communication Facility-Jan2011.doc CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX: (206) 431-3665 E-mail: planning(a,TukwilaWA.gov WIRELESS TELE- COMMUNICATION FACILITIES APPLICATION FOR STAFF USE ONLY Permits Plus Type: P -WIRE Planner: File Number: U 4- O O� q Application Complete Date: Project File Number: P L/,/('i' p C_,' Application Incomplete Date: Other File Numbers: NAME OF PROJECT/DEVELOPMENT: SE03XC409-SR-599 antenna per sector (1 total) and 1 new IRU per sector (3 total) LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. 10825 E Marginal Way S Sprint proposes to install 1 new panel LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). 0323049198 DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City, to whom all notices and reports will be sent. Name: Address: Phone: (503) 476-4883 FAX: Amanda Hoffman-Smartlink LLC 14432 SE Eastgate Way, Ste. 260, Bellevue, WA 98007 E-mail: amanda.hoffman@smartlinkllc.com Signature: Date: 5/16/14 HALand Use Applications in PDF\Wireless Communication Facility-]an2011.doc DECEIVED MAY 292014 (:r)MMtNI 1 Y DEVELOPMENT CALL TOLL FREE: 811 Sprint> 2 WORKING DAYS BEFORE YOU DIG CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE NTH THE CURRENT EDITIONS G THE FOLLOINNG CODES AS ADOPTED BY TIE LOCAL GOWIBING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES 1. 2012 INTERNATIONAL BUILDING CODE 2. 2012 NATIONAL ELECTRICAL CODE 3. 2012 INTERNATIONAL FIRE CODE 4. 2012 INTERNATIONAL MECNANICAL CODE 5. 2012 INTERNATIONAL PLUMBING CODE TIE FAOU1Y IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIRE/047S ARE NOT REQUIRED IN ACCORDANCE LATH THE EC A 1EOMICIAN MNL VISIT TIE STE AS REQUIRED FOR ROUTINE MAINTENANCE THE PR0.ECT MILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE: NO SANITARY SEVER SERVICE, POTABLE WATER OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED. PROJECT DESCRIPTION SPRINT PROPOSES TO MODIFY AN EASING UNMANNED TELECOMMUNICATIONS FACILITY: • REMOVE (1) ERSING SPRINT ANTENNA PLATFORM • INSTALL (3) NEW SPRINT ANTENNA MOUNTS • INSTALL (3) NEW SPRINT RRII/RRU MOUNTS • RELOCATE (3) DOSING SPRINT ANTENNAS (1 PER SECTOR) • RELOCATE (3) EXISTING SPRINT RRU'S (1 PER SECTOR) • INSTALL (3) NEW SPRINT ANTENNAS (1 PER SECTOR) • INSTALL (3) NEW SPRINT RAPS (1 PER SECTOR) • INSTALL (3) NEW SPRINT RADAR FLIERS (1 PER SECTOR) SIGNATURE BLOCK THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS & AUTHORIZE THE SUBCONTRACTOR TO PROCEED MGH CONSTRUCTION DESCRIBED HEREIN. A/J. DOCUMENTS ARE SU&ECT 10 REVEW 8Y DE LOCAL BUILDING DEPARTMENT & MAY IMPOSE CHANGES OR MODIFICATIONS. DISCIPLIC: SIGNATURE DAIS SITE ACQUISITION MANAGER: T-3 GENERAL NOTES CONSTRUCTION MANAGER OVERALL STE PLAN A-2 ANE MANAGEit A-3 SOUTH ELEVATIONS PLANNING CONSULTANT: EAST ELEVATIONS A-5 RF MANAGER: G-1 GROUNDING PLANS & DETAILS RF ENGINEER 0 02-19-14 PROPERTY DINER REV. DATE SPRINT REPRESENTATIVE DRAWN BY: JC CHECKED BY: VD AAV MANAGER: PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: TI TLE SHEET RECEIVED MAS 292014 DE��LUNML.NT SPRINT 2.5 SR599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY LATITUDE: 47' 30' 21.016" (2C) LONGITUDE: -12T 17' 28.411" (2C) GUYED TOWER ON ROOFTOP, SEATTLE MARKET AREA MAP 161 a SITE Gest Cafe 6 Trryal, R40 701 Fad Trucl Centel Seorzk NOT TO SCALE Jaya.. Brio IMAGE SOURCE: GOOCLE MAPS / BONG VICINITY MAP IMAIGt SOURCE GOOLE MAPSF / BAC DRIVING DIRECTIONS FROM SPRINT OFFICE IN: BELLEVUE, WASHINGTON TO SITE HEAD SOUTH ON 124TH AVE NE TOWARD NE LOTH PL 135 FT TAKE THE 1ST RIGHT ONTO NE 10TH PL 459 FT CONTINUE ONTO BELLEWE REDMOND RD/BEL RED RD 0.3 M CONTINUE ONTO NE 81H ST 0.4 W SUGHT RIGHT ONTO THE 1-405 5 RALE 0.2 M1 KEEP LEFT AT THE FORIC AND MERG ONTO 1-405 5 13.3 MI TAKE THE EXIT ONTO 1-5 N TOWARD SEATTLE 1.4 111 SLIGHT RIGHT ONTO WA -599 N (SIGNS FOR TUCIMILA/N MARGINAL WAY) 1.8 MI TACE THE TUNLVA.A INTERNATIONAL BLVD N EXIT 0.3 M MERGE ONTO TUKWILA INTERNATIONAL BLVD 0.5 58 TIJRN RIGHT TOWARD E MARGINAL WAY 5 105 FT SLIGHT RIGHT ONTO E MARGINAL WAY 5 292 FT DESTINATION MILL BE ON THE RIGHT SHEET DESCRIPTION 1-1 TITLE SHEET T-2 GENERAL NOTES T-3 GENERAL NOTES A-1 OVERALL STE PLAN A-2 ENLARGED ANTENNA LAYOUT A-3 SOUTH ELEVATIONS A-4 EAST ELEVATIONS A-5 DETAILS -- - G-1 GROUNDING PLANS & DETAILS 90% CONSTRUCTION DRAWINGS 0 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: TI TLE SHEET SHEET NUMBER: T-1 REV.: 3 SITE INFORMATION APPLICANT COMPANY: ADDRESS CITY. STATE, ZIP: SPRINT 1000 124TH AVE. SUITE 201 BELLEVUE, WA 98005 PROPERTY INFORMATION: PROPERTY OMNER: ADDRESS CONTACT: PH: TOTER 011.1468 STE R PA802 LLC VANCOUVER. WA 98660 PAUL MCEWONGER (360) 696-3312 MOON UNKNOWN ZONING CLASSIFICADOI: CONSTRUCTION TYPE OCCUPANCY: JURISDICTION: CURRENT USE: NEW USE: APN f LEASE AREA DOC1 U/450/U LI601WW1 U MACULA UNMANNED TFIECOWIMNCATIONS FACILITY UNMANNED TELECOYILINICATIONS FACILITY 032304-9198 UNKNOWN PROJECT TEAM ENGINEER COMPANY: ADDRESS: CITY, STATE. ZIP: CONTACT: PHONE E—MAIL: SMARTUNK, LLC 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE. WA 98007-6493 VLAD DIACCNU (425) 274-4444 5148 NoddaeonuOsmartltnWle.eom SITE ACQUISITION/PROJECT MANAGER COMPANY: SMARTUNK. LLC ADDRESS: 14432 5E EASTGATE WAY. SUITE 260 CITY. STATE, ZIP: BEUEWE, WA 98007-6493 CONTACT: KATE JOHNSON PHONE (206) 604-7760 E—MAIL: katIeJohnsonOemorUinklle.eom CONSTRUCTION MANAGER COMPANY: ADDRESS CI1Y, STATE. DP: CONTACT: PHONE E—MAIL: RF ENGINEER COMPANY: ADDRESS: OM STATE. ZIP: CONTACT: PHONE E—MAIL PERMITTING COMPANY: ADDRESS CITY. STATE. LP: CONTACT: PHONE E—MAIL: SPRINT 1000 1241)4 AVE. SUITE 201 BELLEVUE. WA 98005 JIM ZACHARIASEN (425) 387-2404 )amos.zaaharlasenOsprInt.aom SAMSUNG 1000 124TH AVE BELLEWE. WA 98005 DONNY BUI (503) 750-9870 d.butOeta.smnsung.eom SMAR1UNK. LLC 14432 SE EASTGATE WAY. SUITE 260 BELLEVUE, WA 98007-6493 AMANDA NATIONS (206) 492-2294 amando.natIon.OsmarUlnkUe.eam 41€1-0631" Sprint' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO SPRINT LS STRICTLY PROHIBITED ,,, .. smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007-6493 TEL: (425) 274-4444 FAX: (425) 274-4449 3 05.19.14 STRUCTURAL MODIFICATION 2 04-16-14 100% CONSTRUCTION DRAWINGS 1 02-20-14 90% CONSTRUCTION DRAWINGS 0 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: TI TLE SHEET SHEET NUMBER: T-1 REV.: 3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN. AS IN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF SMARTUNK, LLC AND ARE NOT TO 8E USED, IN WHOLE OR IN PART. FOR OTHER PROJECTS WITHOUT THE MR111E14 AUTHORIZATION OF S54ARTUNK, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE APPROVAL OF THE UCENSED PROFESSIONAL IN WRITING. GENERAL CONSTRUCTION NOTES 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL BUILDING CODE. THE LATEST EDITION AND ALL OTHER APPUCABLE CODES AND ORDINANCES. 2. CONTRACTOR SHALL CONSTRUCT SATE IN ACCORDANCE WITH THESE DRAWINGS AND SPRINT INTEGRATED CONSTRUCTION STANDARDS FOR WIRELESS SITES (LATEST REVISION). THE SPECIFICATION IS THE RUUNG DOCUMENT AND ANY DISCREPANCIES BETWEEN THE SPEOFICATION AND THESE DRAWINGS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION. 3. CONTRACTOR SHALL VISIT THE JOB SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE NEW WORK AND SHALL MAKE PROVISIONS AS TO THE COST THEREOF. FIELD CONDITIONS AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. NO COMPENSATION WILL BE AWARDED BASED ON CLAIM OF LACK OF KNOWLEDGE OF FIELD CONDITIONS. 4. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLMNE ONLY UNLESS OTHERWISE NOTED. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT AND APPURTENANCES, AND LABOR NECESSARY TO EFFECT AU. INSTALLATIONS AS INDICATED ON THE DRAWINGS. 5. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EOUPMDIT IS REQUIRED CLEARANCE THEREFORE. IT IS CRITICAL TO FIELD VERIFY DIMENSIONS SHOULD THERE BE ANY QUESTIONS REGARDING TME CONTRACT DOCUMENTS, EXISTING CONDITIONS AND/OR DESIGN INTENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE WORK. 6. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS. AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 7. CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING. AND SHALL RECEIVE IN WRITING AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEMS NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 8. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST CONSTRUCTION SKILLS AND ATTENTION. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER CONTRACT, UNLESS OTHERWISE NOTED. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE UKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS 10. CONTRACTOR SHALL COORDINATE HIS WORK WITH 114E SUPERINTENDENT OF BUILDINGS & GROUNDS AND SCHEDULE HIS ACTIVITIES AND WORKING HOURS IN ACCORDANCE WITH THE REQUIREMENTS 11. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH THE WORK OF OTHERS A5 IT MAY RELATE TO RADIO EQUIPMENT. ANTENNAS AND ANY OTHER PORTIONS OF THE WORK. 12. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 13. MAKE NECESSARY PROVI90NS TO PROTECT EXISTING SURFACES, EQUIPMENT, IMPROVEMENTS, PIPING ETC. AND IMMEDIATELY REPAIR ANY DAMAGE THAT OCCURS DURING CONSTRUCTION. 14. IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR ANCHORING PURPOSES, OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT RUNS, PIPE RUNS. ETC.. MUST BE CLEARLY UNDERSTOOD THAT REINFORCING STEEL SHALL NOT BE DRILLED INTO. CUT OR DAMAGED UNDER ANY CIRCUMSTANCES (UNLESS NOTED OTHERWISE). LOCATIONS OF REINFORCING STEEL ARE NOT DEFINITELY KNOWN AND THEREFORE MUST BE SEARCHED FOR BY APPROPRIATE METHODS AND EQUIPMENT. 15. REPAIR AU. EXISTING WALL SURFACES DAMAGED DURING CONSTRUCTION SUCH THAT THEY MATCH AND BLEND IN WITH ADJACENT SURFACES. 16. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L USTED AND FIRE COOE APPROVED MATERIALS. 17. KEEP CONTRACT AREA CLEAN, HAZARD FREE. AND DISPOSE OF ALL DIRT. DEBRIS. AND RUBBISH. EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OF THE OWNER SHALL BE REMOVED. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL ITEMS UNTIL COMPLETION OF CONSTRUCTION. 18. MINIMUM BEND RADIUS OF ANTENNA CABLES SHALL BE IN ACCORDANCE WITH CABLE MANUFACTURERS RECOMMENDATIONS 19. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES. IF REQUIRED DURING CONSTRUCTION SHALL BE IN CONFORMANCE WITH JURISDICTIONAL OR STATE AND LOCAL GUIDELINES FOR EROSTION AND SEDIMENT CONTROL AND COORDINATED W11H LOCAL REGULATORY AUTHORITIES 20. UGHT SHADED UNES AND NOTES REPRESENT WORK PREVIOUSLY DONE. DARK SHADED UNES AND NOTES REPRESENT THE SCOPE OF WORK FOR THIS PROJECT. CONTRACTOR SHALL VERIFY IF EXISTING CONSTRUCTION IS COMPLETE CONTRACTOR SHALL NOTIFY ENGINEER OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWINGS PRIPOOR TO BEGINNING CONSTRUCTION. 21. CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS AND/OR WIRING CERTIFICATES REQUIRED FOR THE ELECTRICAL SERVICE UPGRADE. IN ADDITION. CONTRACTOR SHALL PROVIDE ALL NECESSARY COORDINATION AND SCHEDULING WITH THE SERVING ELECTRICAL U1IUTY AND LOCAL INSPECTION AUTHORITIES. ELECTRICAL NOTES 1. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ANY/ALL ELECTRICAL WORK INDICATED. ANY/ALL CONSTRUCTION SHALL BE IN ACCORDANCE W/DRAWINGS AND ANY/ALL APPUCABLE SPECIFICATIONS IF ANY PROBLEMS ARE ENCOUNTERED BY COMPLYING WITH THESE REQUIREMENTS, CONTRACTOR SHALL NOTIFY 'CONSTRUCTION MANAGER' AS SOON AS POSSIBLE. AFTER THE DISCOVERY OF THE PROBLEMS, AND SHALL NOT PROCEED WITH THAT PORTION OF WORK. UNTIL THE 'CONSTRUCTION MANAGER' HAS DIRECTED THE CORRECTIVE ACTIONS TO BE TAKEN. 2. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FAMIUARIZE HIMSELF WITH ANY/ALL COMMONS AFFECTING ELECTRICAL AND COMMUNICATION INSTALLATION AND MAKE PROVISIONS AS TO THE COST THEREOF. ALL EXISTING CONDITIONS OF ELECTRICAL EQUIP.. UGHT FIXTURES, ETC.. THAT ARE PART OF THE FINAL SYSTEM, SHALL RE VERIFIED BY THE CONTRACTOR, PRIOR TO THE SUBMITTAL OF HIS BID. FAILURE TO COMPLY WITH THIS PARAGRAPH WILL IN NO WAY RELIEVE CONTRACTOR OF PERFORMING ALL WORK NECESSARY FOR A COMPLETE AND WORKING SYSTEM. 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL CODES AND LOCAL ORDINANCES OF THE LOCAL POWER & TELEPHONE COMPANIES HAVING JURISDICTION AND SHALL INCLUDED BUT NOT DE UNITED T0: A. UL -- UNDERWRITERS LABORATORIES B. NEC -- NATIONAL ELECTRICAL CODE C. NEMA -- NATIONAL ELECTRICAL MANUFACTURERS ASSOC. D. OSHA -- OCCUPATIONAL SAFETY AND HEALTH ACT E. IBC -- INTERNATIONAL BUILDING CODE F. NEPA -- NATIONAL FIRE CODES 4. 00 NOT SCALE ELECTRICAL DRAWINGS REFER TO SITE PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT. AND CONFIRM WITH 'CONSTRUCTION MANAGER' ANY SIZES AND AND LOCATIONS WHEN NEEDED. 5. EXISTING SERVICES CONTRACTOR SHALL NOT INTERRUPT EXISTING SERVICES WITHOUT WRITTEN PERMISSION OF THE SPRINTIT. 6. CONTRACTOR SHALL PAY FOR ANY/ALL PERMITS, FEES, INSPECTIONS AND TESTING. CONTRACTOR IS TO OBTAIN PERMITS AND APPROVED SUBMITTALS PRIOR TO THE WORK BEGINNING OR ORDERING EQUIPMENT. 7. TIE TERM 'PROVIDE' USED IN CONSTRUCTION DOCUMENTS AND SPECIFICATIONS. INDICATES THAT THE CONTRACTOR SHALL FURNISH AND INSTALL 8. CONTRACTOR SHALL CONFIRM WITH LOCAL UTRITY COMPANY ANY/ALL REQUIREMENTS SUCH AS THE WG S2E RESTRICTIONS, CONDUIT ENTRY, SIZE OF TRANSFORMERS, SCHEDULED DOWNTIME FOR THE OWNERS' CONFIRMATION, ETC. ANY/ALL CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER, PRIOR TO BEGINNING ANY WORK. 9. MINIMUM WIRE SZE SHALL BE /12 AWG, NOT INCLUDING CONTROL WIRING. UNLESS NOTED OTHERWISE. ALL CONDUCTORS SHALL BE COPPER WITH THIN INSULATION. 10. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY W1111 THREADED HUBS IN VIET/DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS 11. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF THE CONSTRUCTION. CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL 170,15 FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS FOR THE EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 12. ELECTRICAL SYSTEM SHALL BE AS COMPLETELY AND EFFECTIVELY GROUNDED. AS REQUIRED BY SPECIFICATION, SET FORTH BY SPRINT. 13. ALL WORK SHALL BE PERFORMED BY A UCENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULL OPERATIVE AND SUBJECT TO REGULATORY INSPECTION AND APPROVAL BY CONSTRUCTION MANAGER. 14. AU. WORK SHALL 8E COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 15. CONTRACTOR SHALL GUARANTEE ANY/ALL MATERIALS AND WORK FREE FROM DEFECTS OR A PERIOD OF NOT LESS THAN TWO YEARS FROM DATE OF CUSTOMER'S ACCEPTANCE. 16. THE CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ANY ADDITIONAL CHARGE AND SHALL INCLUDE THE REPLACEMENT OF THE REPAIR OF ANY OTHER PHASE OF THE INSTALLATION. WHICH MAY HAVE BEEN DAMAGED THEREIN WITHIN 48 HOURS. 17. ADEQUATE AND REQUIRED UABIUTY INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBUC LOSS AND ANY/ALL PROPERTY DAMAGE FOR THE DURATION OF WORK. 18. PROVIDE AND INSTALL CONDUIT. CONDUCTORS. PULL WIRES, BOXES, COVER PLATES AND DEVICES FOR ALL OUTLETS AS INDICATED. 19. DITCHING AND BACK FILL: CONTRACTOR SHALL PROVIDE FOR AU. UNDERGROUND INSTALLED CONDUIT AND/OR CABLES INCLUDING EXCAVATION AND BACKFIRING AND COMPACTION. REFER TO NOTES AND REQUIRDIENTS. EXCAVATION, AND BACKFIWN0. 20. MATERIALS. PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND SHALL APPEAR ON THE UST OF U.L APPROVED ITEMS AND SHALL MEET OR EXCEED THE REQUIREMENTS OF TIE NEC. NEN* AND IEEE. 21. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR MANUFACTURES CATALOG INFORMATION OF ANY/ALL UGHIING FIXTURES, SWITCHES AND ALL OTHER ELECTRICAL 11015 FOR APPROVAL BY THE CONSTRUCTION MANAGER PRIOR 70 INSTALLATION. 22. ANY CUTTING OR PATCHING DEEMED NECESSARY FOR ELECTRICAL WORK IS THE ELECTRICAL CONTRACTORS RESPONSE/1111Y AND SHALL BE INCLUDED IN THE COST FOR WORK AND PERFORMED TO THE SATISFACTION OF THE 'CONSTRUCTION MANAGER' UPON FINAL ACCEPTANCE. 23. THE ELECTRICAL CONTRACTOR SHALL LABEL ALL PANELS WITH ONLY TYPEWRITTEN DIRECTORIES. ALL ELECTRICAL WIRING SHALL BE THE RESPONSIBIUTY OF THE ELECTRICAL CONTRACTOR. 24. DISCONNECT SWITCHES SHALL BE H.P. RATED HEAVY-DUTY, QUICK -MAKE AND QUICK -BREAK ENCLOSURES, AS REQUIRED BY EXPOSURE TYPE. 25. ALL CONNECTIONS SHALL BE MADE WITH A PROTECTIVE COATING OF AN ANTI -OXIDE COMPOUND SUCH AS NO -OXIDE A' BY DEARBORNE CHEMICAL CO. COAT ALL WIRE SURFACES BEFORE CONNECTING. EXPOSED COPPER SURFACES. INCLUDING GROUND BARS. SHALL BE TREATED - NO SUBSTITUTIONS 26. REACEWAYS: CONDUIT SHALL BE SCHEDULE 40 PVC MEETING OR EXCEEDING NEMA TC2 - 1990. CONTRACTOR SHALL PLUG AND CAP EACH END OF SPARE AND EMPTY CONDUITS AND PROVIDE TWO SEPARATE PULL STRINGS - 200 LBS TEST POLYETHYLENE CCM. ALL CONDUIT BENDS SHALL 8E A MINIMUM OF 2 FT. RADIUS. RGS CONDUITS WHEN SPECIFIED. SHALL MEET UL -6 FOR GALVANIZED STEEL ALL FITTINGS SHALL BE SUITABLE FOR USE WITH THREADED RIGID CONDUIT. COAT ALL THREADS WITH 'BRITS ZINC' OR 'GOLD CALV. 27. SUPPORT OF ALL ELECTRICAL WORK SHALL BE AS REQUIRED BY NEC. 28. CONDUCTORS CONTRACTOR SHALL USE 9816 CONDUCTIVITY COPPER WITH TYPE THIN INSULATION, 600 VOLT, COLOR CODED. USE SOLID CONDUCTORS FOR WIRE UP TO AND INCLUDING N0. 8 AWG. USE STRANDED CONDUCTORS FOR WIRE ABOVE N0. 8 AWG 29. CONNECTORS FOR POWER CONDUCTORS CONTRACTOR SHALL USE PRESSURE TYPE INSULATED TWIST -ON CONNECTORS FOR NO. 10 AWG AND SMALLER. USE SOLDERLESS MECHANICAL TERMINAL LUGS FOR NO. 8 AWG AND LARGER. 30. SERVICE 240/120V. SINGLE PHASE 3 WIRE CONNECTIONS AVAILABLE FROM UTILITY COMPANY. OWNER OR OWNERS AGENT WILL APPLY FOR POWER. 31. TELEPHONE SERVICE: CONTRACTOR SHALL PROVIDE EMPTY CONDUITS WITH MULE TAPE AS INDICATED ON DRAWINGS. 32. ELECTRICAL AND TELCO RACEWAYS TO BE BURIED A MINIMUM OF 2' DEPTH. 33. CONTRACTOR SHALL PLACE TWO LENGTHS OF WARNING TAPE AT A DEPTH OF 12' BELOW GROUND AND DIRECTLY ABOVE ELECTRICAL AND TELCO SERVICE CONDUITS. CAUTIONS TAPE TO READ 'CAUTION BURIED ELECTRIC OR 'BURIED TELECOM'. 34. ALL BOLTS SHALL BE STAINLESS STEEL ANTENNA & COAX NOTES • VERIFY EACH COAXIAL CABLE LENGTH. DIAMETER. ROUTING. COLOR COOING AND ALL APPURTENANCES WITH SPRINT 4. ALL TOP JUMPERS SHALL BE LENGTHS A5 SHOWN AND INSTALLED BY CONTRACTOR. 5. ALL CABLES SHALL BE COLOR COOED IN ACCORDANCE W11H SPRINT SPECIFICATIONS. 6. BANDING SHALL BE IN ACCORDANCE NTH SHEET A-4, RF -1 AND AS FOLLOWS: A. MAIN UNE COLOR BANDS SHALL BE 2 WIDE. MAINTAIN 1' SPACING BETWEEN COLORS. B. FREQUENCY COLOR BANDS SHALL BE 2 WIDE WITH NO SPACE BETWEEN COLORS. C. JUMPER COLOR BANDS SHALL BE 1' WIDE WITH 1' SPACE. D. START COLOR BANDS 2 BEYOND WEATHERPROOFING. E START SELECTOR COLOR NEXT 10 END CONNECTORS 7. SEE CONSTRUCTION MANAGER FOR ANTENNA SUPPORT ASSEMBLY TYPE 8. PROVIDE AT LEAST 6' OF SLACK IN THE MAIN COAXIAL CABLES AT THE ANTENNA MOUNTING ELEVATION TO PROVIDE FOR FUTURE CONNECTOR REPLACEMENT. I=NVIRONMENTAL NOTES 1. ALL WORK PERFORMED SHALL BE DONE IN ACCORDANCE WITH ISSUED PERMITS THE CONTRACTOR SHALL BE RESPONSIBLE FOR PAYMENT OF FINES AND PROPER CLEAN UP FOR AREAS IN VIOLATION. 2. CONTRACTOR AND/OR DEVELOPER SHALL BE RESPONSIBLE FOR CONSTRUCTION AND MAINTENANCE OF EROSION AND SEDIMENTATION CONTROLS DURING CONSTRUCTION FOR PROTECTION OF ADJACENT PROPERTIES. ROADWAYS AND WATERWAYS AND SHALL 82 MAINTAINED IN PLACE THROUGH FINAL JURISDICTIONAL INSPECTION & RELEASE OF SITE. 3. CONTRACTOR SHALL INSTALL/CONSTRUCT ALL NECESSARY SEDIMENT/SILT CONTROL FENCING AND PROTECTIVE MEASURES WITHIN THE UNITS OF SITE DISTURBANCE PRIOR TO CONSTRUCTION. 4. NO SEDIMENT SHALL BE ALLOWED TO EXIT THE PROPERTY. THE CONTRACTOR IS REPSONIBLE FOR TAKING ADEQUATE MEASURES FOR CONTROLLING EROSION. ADDITIONAL SEDIMENT CONTROL FENCING MAY BE REQUIRED IN ANY AREAS SUBJECT TO ER090N. 5. THE CONTRACTOR I5 RESPONSIBLE FOR MAINTAINING POSITIVE DRAINAGE ON TME 9TE AT ALL TIMES WITH SILT AND ER090N CONTROL MEASURES MAINTAINED ON THE DOWNSTREAM SIDE OF STE DRAINAGE. ANY DAMAGE TO ADJACENT PROPERTY AS A RESULT OF EROSION WILL BE CORRECTED AT THE CONTRACTORS EXPENSE. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR DALY INSPECTIONS AND ANY REPAIRS OF ALL SEDIMENT CONTROL MEASURES INCLUDING SEDIMENT REMOVAL AS NECESSARY. 7. CLEARING OF VEGETATION AND TREE REMOVAL SHALL BE ONLY AS PERMITTED AND BE HELD TO A MINIMUM. ONLY TREES NECESSARY FOR CONSTRUCTION OF THE FAOUTIES SHALL BE REMOVED. & SEEDING SAND MULCHING AND/OR SODDING OF THE SITE WILL BE ACCOMPUSHED AS 50014 AS POSSIBLE AFTER COMPLETION OF THE PROJECT FACIUTES AFFECTING LAND DISTURBANCE 9. CONTRACTOR SHALL PROVIDE ALL EROSION AND SEDIMENTATION CONTROL MEASURES AS REQUIRED BY LOCAL, COUNTY AND STATE CODES AND ORDINANCES TO PROTECT EMBANKMENTS FROM SOIL LOSS AND TO PREVENT ACCUMULATION OF SOL AND SILT IN STREAMS AND DRAINAGE PATHS LEAVING THE CONSTRUCTION AREA. THIS MAY INCLUDE SUCH MEASURES AS SILT FENCES, STRAW BALE SEDIMENT BARRIERS, AND CHECK DAMS STRUCTURAL STEEL NOTES 1. ALL STEEL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF TME NSC MANUAL OF STEEL CONSTRUCTION. STEEL SECTIONS SHALL BE IN ACCORDANCE WITH ASTM AS INDICATED BELOW: W -SHAPES ASTM A992. 50 KSI ANGLES, BARS CHANNELS: ASTM A36, 36 K9 HSS SECTIONS: ASTM 500. 48 KS PIPE SECTIONS: ASTM A53 -E. 35 KSI 2. ALL EXTERIOR EXPOSED STEEL AND HARDWARE SHALL 8E HOT DIPPED GALVANIZED. 3. ALL WELDING SHALL 8E PERFORMED USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AMSC. WHERE FILLET WELD SIZES ARE NOT SHOWN. PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE NSC 'MANUAL OF STEEL CONSTRUCTION'. PAINTED SURFACES SHALL BE TOUCHED UP. 4. NON-STURCUTRAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8'0 ASTM A 307 BOLTS UNLESS NOTED OTHERWISE. 5. FIELD MODIFICATIONS ARE TO 86 COATED WITH ZINC ENRICHED PANT. L /'/-6031 Sprint' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO SPRINT IS STRICTLY PROHIBITED ,/, de. s• smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007-6493 TEL: (425) 274-4444 FAX: (425) 274-4449 3 05.19.14 STRUCTURAL MODIFICATION 2 04-16-14 100% CONSTRUCTION DRAWINGS 1 02.20-14 90% CONSTRUCTION DRAWINGS 0 02-19-14 BO% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: GENERAL NOTES SHEET NUMBER: T-2 REV.: 3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS IN INSTRUMENT OF PROFESSIONAL SERVICE ARE THE PROPERTY OF SMARTUNK, LLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROECTS WITHOUT THE WRITTEN AUTHORIZATION OF SMARTUNK, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE APPROVAL OF THE LICENSED PROFESSIONAL IN WRITING. WEATHERPROOFING NOTES 1. WEATHERPROOFING CONNECTORS AND GROUND KITS A ALL CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED USING BUTYL RUBBER WEATHERPROOFING AND TAPE. THIS INSTALLATION MUST BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION OR AS SHOWN ON THE CONSTRUCTION DRAWINGS (WHICHEVER 15 GREATER). IF NO DIRECTION IS PROVIDED. WEATHERPROOFING MUST BE DONE PER 7HE FOLLOWING INSTRUCTIONS. 1. DE HYBRID CABLE CONNECTION OR GROUND KIT CAN BE ENCOMPASSED INTO COLD SHRINK AND COMPLETELY WRAPPED WITH 2 INCH MADE ELECTRICAL TAPE OVERLAPPING EACH ROW BY APPROXIMATELY 14' AND EXTENDING PAST THE CONNECTION BY TWO INCHES AS DISCUSSED BELOW: OR 2. THE HYBRID CABLE CONNECTION OR GROUND KR CMI BE WRAPPED WITH LAYERS OF ELECTRICAL/BUTYL RUBBER/ELECTRICAL TAPE AS DISCUSSED BELOW: OR 3. THE HYBRID CABLE CONNECTION OR GROUND KIT CAN BE WRAPPED WRH TWO LAYERS OF 1.5 INCH WEE SELF -AMALGAMATING TAPE COVERED WITH TWO LAYERS OF ELECTRICAL TAPE AS DISCUSSED BELOW. P. COLD SHRINK INSTALLATION PROCEDURE: 1. REQUIRED MATERIAL COLD SHRINK TUBE. SPACERS AS NEEDED. BLACK ELECTRICAL TAPE -2 INCHES WIDE 2. REQUIRED TOOLS: KNIFE AND TAPE MEASURE STEP 1: THOROUGHLY CLEAN AND DRY THE SURFACE OF HYBRID CABLE AND CONNECTOR TO REMOVE ALL GREASE AND DIRT. MARK THE MAIN FEED (LARGER DIAMETERE) HYBRID CABLE AT LEAST 1W0 INCHES ABOVE THE CONNECTION AS THE SPECIFIED START DIMENSION FOR THE COLD SHRINK. STEP 2: SLIDE THE COLD SHRINK TUBE OVER THE PRE-CONMECTORIZED END OF THE LARGER DIAMETER HYBRID CABLE PRIOR TO MATING CONNECTOR INTERFACES. MANE THE CONNECTION. STEP 3: REMOVE WAX PAPER FROM A SPACER HALF AND PRESS ONTO HYBRID CABLE DIRECTLY BEHIND THE CONNECTOR. REMOVE THE WAX PAPER FROM THE OTHER SPACER HALF AND AUGN THE TWO SPACER HALVES WITH ADHESIVE PORTIONS FACING EACH OTHER. PRESS THE SPACER HALVES TOGETHER. THE SPACER WILL BE PLACED NEXT TO THE CONNECTOR ON THE SMALLER DIAMETER HYBRID CABLE SIDE. STEP 4: SLIDE THE COLD SHRINK TUBE OVER THE CONNECTION 10 THE SPECIFIED START DLIEHSION MURK. HOLD THE COLD SHRINK TUBE AND HYBRID CABLE IN ONE WIND SO THAT THE EDGE OF COLD SHRINK TUBE IS IN UNE WITH THE MARK. STEP 5: WITH YOUR FREE HAND. BEGIN REMOVING COLD SHRINK TUBE CORE. THE CORE WILL BE REMOVED BY UNWINDING IN A COUNTERCLOCKWISE DIRECTION WHILE UGHTLY PUUJNG THE ATTACHED CORD AWAY FROM THE TUBE. STEP 6: USE BOTH HANDS TO CONTINUE THE UNWINDING PROCESS AS THE COLD SHRINK TUBE BEGINS TO COLLAPSE INTO POSITION. CONTINUE THE UNWINDING PROCESS UNTIL THE CORE IS COMPLETELY REMOVED AND THE COLD SHRINK TUBE IS INSTALLED. STEP 7: EXCESS COLD SHRINK TUBE EXTENDING TWO INCHES BEYOND THE SPACER HALVES CAN BE REMOVED OR LEFT IN PLACE. EXCESS COLD SHRINK TUBE CAN BE CAREFULLY CUT OFF WITH A KNIFE. STEP 8: WRAP OVER TIE COLD SHRINK TUBE WITH ONE LAYER OF BLACK ELECTRICAL TAPE 2 INCH WIDTH OVERLAPPING EACH ROW BY 1/2 INCH. THIS TOP LAYER MUST BE WRAPPED USING A SHINGLED EFFECT. THE LAYER SHALL BE WRAPPED 50 THAT THE ENDS ARE IN THE UPWARD DIRECTION CREATING A SHINGLED EFFECT WITH THE TAPE SO WATER WILL BE REPELLED AND NOT ALLOWED TO COLLECT AND POOL THIS TOP LAYER OF ELECTRICAL TAPE MUST EXTEND 1W0 INCHES (THE TAPE WIDTH) PAST THE COLD SHRINK TUBE ONTO THE UNDERLYING CABLE. TAPE SHALL BE WRAPPED SO THAT NO VOIDS OR AIR PACKETS ARE PRESENT. TAPE SHALL BE CUT WITH A SHARP KNIFE. C. BUTYL RUBBER TAPE INSTALLATION PROCEDURE: 1. REQUIRED MATERIAL.: BLACK ELECTRICAL TAPE -2 INCH WIDE AND BUM RUBBER TAPE 2 TO 3 INCHES WIDE. 2. REQUIRED TOOLS: KNIFE OR SCISSORS. STEP 1: THOROUGHLY CLEAN AND DRY THE SURFACE OF HYBRID CABLE AND CONNECTOR TO REMOVE ALL GREASE AND DIRT. WRAP CONNECTOR/GROUND KIT WITH TWO LAYERS OF BLACK ELECTRICAL TAPE -2 INCH WIDTH OVERLAPPING EACH ROW BY APPROXIMATELY 1/2 INCH. THESE LAYERS OF TAPE MUST BE WRAPPED TIGHT ENOUGH SO THAT NO VOIDS OR AIR PACKETS ARE PRESENT AND MUST EXTEND ONE INCH PAST THE CONNECTOR/GROUND KIT ON EACH SIDE. TWO ROWS SHALL BE APPUED. ONE IN EACH DIRECTION. WITH THE TOP ROW SHINGLED TO PROMOTE WATER RUNOFF. STEP 2: WRAP CONNECTOR/GROUND KIT WITH ONE LAYER OF BUM RUBBER TAPE (2 TO 3 INCHES WIDTH) OVER THE BLACK ELECTRICAL TAPE OVERLAPPING EACH ROW BY APPROXIMATELY 1/2 INCH. THE BUM RUBBER TAPE MUST EXTEND 2 TO 3 INCHES (THE TAPE WIDTH) PAST THE ELECTRICAL TAPE AND COME IN GOOD CONTACT WITH THE UNDERLYING CABLE. ON CONNECTORS. WHEN WEATHERPROOFING FROM THE MAIN UNE TO THE JUMPER. BUILD UP THIS AREA WITH EXTRA BUTYL RUBBER TAPE TO INSURE A SMOOTH TRANSITION FREE OF VOIDS AND AR PACKETS DOWN TO 'ME SMALLER DIAMETER GABLE. STEP 3: WRAP CONNECTOR/GROUND KIT WITH TWO LAYERS OF BLACK ELECTRICAL TAPE 2 INCH WIDTH OVERLAPPING EACH ROW BY 1 INCH. THESE LAST 1W0 LAYERS MUST BE WRAPPED USING A SHINGLED EFFECT. THE TOP LAYER SHALL BE WRAPPED SO THAT THE ENDS ARE IN THE UPWARD DIRECTION CREATING A SHINGLED EFFECT WITH THE TAPE SO WATER WILL BE REPELLED AND NOT ALLOWED TO COLLECT AND POOL THESE TOP LAYERS OF ELECTRICAL TAPE MUST EXTEND TWO INCHES (THE TAPE WIDTH) PAST THE BUM RUBBER TAPE ONTO THE UNDERLYING CABLE. ALL LAYERS OF TAPE SHALL BE WRAPPED SO THAT NO VOIDS OR AIR PACKETS ARE PRESENT. THE LAST WRAP OF TAPE SHALL NOT BE PULLED OR STRETCHED. ALL TAPE SHALL BE CUT WITH A SHARP KNIFE OR SCISSORS. D. SELF -AMALGAMATING TAPE INSTALLATION PROCEDURE 1. REQUIRED MATERLAL- SELF -AMALGAMATING TAPE -1.5 INCHES WIDE AND BLACK ELECTRICAL TAPE - 2 INCHES WIDE. 2. REQUIRED TOOLS: KNIFE OR SCISSORS. STEP 1: THOROUGHLY CLEAN AND DRY THE SURFACE OF HYBRID CABLE AND CONNECTOR 10 REMOVE ALL GREASE AND DIRT. STEP 2: START WRAPPING SELF -AMALGAMATING TAPE ON INC CABLE AT LEAST 2 INCHES FROM INC CONNECTOR/GROUND KIT. MAKE SURE TAPE IS STRETCHED TIGHT DURING THIS APPUCARON. STEP 3: WHILE STRETCHING TAPE. MAKE ONE WRAP OF THE TAPE AROUND THE CABLE. MAKING SURE THE TAPE IS WRAPPED ONTO ITSELF. THE TAPE WILL ONLY ADHERE TO ITSELF. STEP 4: CONTINUE WRAPPING THE CABLE AND CONNECTOR/GROUND KIT USING HALF OVERLAP (0.75 INCH WIDE) LAYERS. STEP 5: WRAP OVER AND PAST THE CONNECTOR/GROUND KIT AT LEAST 2 INCHES. STEP 6: TO TERMINATE THE SELF -AMALGAMATING TAPE. WRAP THE TAPE AT LEAST ONE FULL ROUND OVER INC CABLE STRETCHING AHE TAPE TIGHT. CUT THE TAPE USING KNIFE OR SCISSORS AND APPLY THE LOOSE END TO THE UNDERLYING SELF -AMALGAMATING TAPE USING 'THUMB PRESSURE. STEP 7: TWO ROWS OF SELF -AMALGAMATING TAPE SHALL BE APPUED IN THIS MANNER. IN ALTERNATING DIRECTIONS. THE TOP LAYER SHALL 8E WRAPPED SO THAT THE ENDS ARE IN AN UPWARD DIRECTION CREATING A SHINGLED EFFECT WITH THE TAPE SO WATER WILL BE REPELLED. STEP 8: WRAP OVER SELF -AMALGAMATING TAPE WITH TWO LAYERS OF BLACK ELECTRICAL TAPE- 2 INCH WIDTH OVERLAPPING EACH ROW BY 1 INCH. THESE TOP TWO LAYERS MUST ALSO BE WRAPPED USING A SHINGLED EFFECT. THE LAYERS SMALL BE WRAPPED SO THAT THE ENDS ARE IN THE UPWARD DIRECTION CREATING A SHINGLED EFFECT WITH THE TAPE SO WATER WILL BE REPELLED AND NOT ALLOWED TO COLLECT MD POOL THESE 10P LAYERS OF ELECTRICAL TAPE MUST EXTEND TWO INCHES (THE TAPE WIDTH) PAST THE SELF-AMALGAMATNG TAPE ONTO THE UNDERLYING CABLE ALL LAYERS OF TAPE SHALL BE WRAPPED SO THAT NO VOIDS OR AIR PACKETS ARE PRESENT. THE LAST WRAP OF TAPE SHALL NOT BE PULLED OR STRETCHED. ALL TAPE SHALL BE CUT WITH A SHARP KNIFE OR SCISSORS. / q -D Da3r Sprint' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS LS PROPRIETARY 8 CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO SPRINT IS STRICTLY PROHIBITED ,,, de Ie •#` smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007-6493 TEL: (425) 274-4444 FAX: (425) 274-4449 3 05.19.14 STRUCTURAL MODIFICATION 2 04-1614 100% CONSTRUCTION DRAWINGS 1 022014 90% CONSTRUCTION DRAWINGS 0 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: GENERAL NOTES SHEET NUMBER: T-3 REV.: 3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS IN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF S.MARTUNK, LLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF SMARRANK, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE APPROVAL OF THE LICENSED PROFESSIONAL IN WRITING. t /DOSING COMMERCIAL AREAPARIONG DOTING COMMERCIAL BUILDING. TMP. DISCLAIMER THESE DRAWINGS %ERE PRODUCED WITHOUT THE BENEFIT OF A CURRENT LAND SURVEY. ALL PROPERTY ONES, EASEMENTS, AND SETBACKS SHALL BE AIMED PRIOR TO START OF CONSIRUCDON. SMARTLNK DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY UNES, EASEMENTS AND SETBACKS APN: 032304-9198 s 8443'30 S B4'43'30��W 1 1 1 N -33 N /FASTING COMMERCIAL AREA/PARKING POSTING COMYMEROAL BUILDING, TMP. EXISTING RAILWAY TRACK L /1/P4J9' TN MN OVERALL SITE PLAN 22•x34' SCALE: 1' 30'4' 11':1T SCALE: 1' • 60'-0' 30 1' 1 Sprint' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY 9. CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO SPRINT IS STRICTLY PROHIBITED " / e ,40 smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007-6493 TEL: (425) 274-4444 FAX: (425) 274-4449 3 05-19-14 STRUCTURAL MODIFICATION 2 04.16-14 100% CONSTRUCTION DRAWINGS 1 02-20-14 90% CONSTRUCTION DRAWINGS 0 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD �BnO OPS. of wAsy, tP,d) a. 1 t)iz4vti AL• PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: OVERALL SITE PLAN SHEET NUMBER: A 1 REV.: 3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS IN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF SMARTUNK, LLC AND ARE NOT TO BE USED. IN WHOLE OR IN PART. FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF SMARTIJNK, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE APPROVAL OF THE LICENSED PROFESSIONAL IN WRITING, Sprint' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY 8 CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO SPRINT IS STRICTLY PROHIBITED ,,, if ,,, smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007-6493 TEL: (425) 274-4444 FAX: (425) 274-4449 EXISTING MOUNTING PLANES ANGLES NOTE: 1. DOSING ANTENNAS BY OTHER CARTERS, NOT ON THE SAME RAD CENTER ALPHA 0' As SPRIT. ARE NOT SHOWN FOR CLARITY - SEE EEVATION SECTS. BETA 120' 05-19-14 STRUCTURAL MODIFICATION GAMMA 240' 100% CONSTRUCTION DRAWINGS 1 SECTOR HA „ (0 BE RELOCATED. (E) SPRINT 1))PER SECTOR, b (3) TOTAL < 9. - (E) 1YP. SPOF RIN9T EMPTY PIPE MOUNT • • ,•......•• .w.� O . `�,' � \-‘1• SECTOR "C" litvf (E) SPRINT TRIPS TO BE I'I ,�'/ (3) IOTIED, (1) PER SECTOR, (3) TOTAL (E RRELOCATED. (1)SPRINT �STO BE PER SECTOR. i►� (3) TOTAL (E) CANED ANTENNAS TO BE , RELOCATED. (1) PER SECTOR. (3) TOTAL O (E) SPRINT ANTENNAS TO BE TOTAL (1) PER SECTOR (3) SECTOR "B" 20. (E) SPRINT RRU'S TO BE O • RELOCATED. (1) PER SECTOR O/ `4` (3) TOTAL �' tip TN MN ' I^ 1i s• � (E) PLATFORM TO BE REMOVED EXISTING ANTENNA PLAN SCALE:1/8"•1 ' 1 NOT USED "SCALE 2 1 -' o r� 1 (N) VALMONT CWf02-LL T -MOUNTS W • SECTOR "A" RI NOTE 1. DOMING ANTENNAS BY OTHER CARRIERS, NOT ON THE SAME RAD CENTER AS SPRINT. ARE NOT SHOWN FOR CLARITY - SEE ELEVATION SHEETS 2. MAINTAIN MINIMUM 20 NOES BETWEEN ANTENNAS. 3. ALL MOUNTING PIPES FOR 2.5 ANTENNA AND MU INSTALLATION ARE TO BE 3' DIAMETER. GC 10 REPLACE EXISTING PIPES F THEY DO NOT MEET TMS STANDARD. (N) SPRINT 25004•12 ANIMA. STRUCTURAL ANALYSIS MUST BE PERFORMED BEFORE INSTALLATION OF NEW ANTENNAS & NEW RRUS NQTEL EXISTING ANTENNAS ARE CDMA UNLESS NOTED OTHERWISE NEW SPRINT ANTENNAS INCLUDE RESPECTIVE RRU'S WHICH SHALL BE MOUNTED NEAR THE ANTENNA. FIELD VERIFY EXISTING AZIMUTH BEFORE RELOCATING THE ANTENNA. IF REWIRED. PRIOR APPROVAL FROM SPRINT TO BE GRANTED BEFORE RELOCATION OF ANTENNAS AD�i ALL AZMIUTHS ARE TO BE ESTABLISHED CLOCKWISE FROM THE TRUE NORTH HEADING. CONTRACTOR SHALL VERIFY NEW ANTENNA RAD CENTER AND ORIENTATIONS WITH SPRINT PCS PRIOR TO INSTALLATION OF ANTENNAS PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, SUITABILITY OF EXISTING FRAME MUST BE ANALYZED BY A UCENSED STRUCTURAL ENGINEER TO VERIFY FRAME IS CAPABLE OF SUPPORTING THE NEW LOADS. REFER TO STRUCTURAL ANALYSIS BY GENERAL DYNAMICS CONTRACTOR SHALL REFER TO STRUCTURAL CALCULATIONS FOR ADDITIONAL LOADS NO ERECTION OR MODIFICATION OF TANK SHALL BE MADE WITHOUT APPROVAL OF STRUCTURAL ENGINEER. PAINT NOTES: (1) PER SECTOR, TOTAL CF (3) ® IX _ b (1) PER SECTOR (3) TOTAL O ® (N) VALMONT R5 UNIVERSAL PIPEWJE', YOUNT. (1) PER SECTTOTAL OF `c •�� 1-= (N) SPROUT 2500MHz TRH, 1. (N) SPRINT EXPOSED ANTENNAS AND MOUNTING HARDWARE TO BE PAINTED TO MATCH (E) SITE CONDITIONS PER EQUIPMENT MANUFACTURER'S RECOMMENDATIONS 2. (N) SPRINT EXPOSED ANTENNA SUPPORT EQUIPMENT AND MOUNTING HARDWARE TO BE PANTED TO MATCH (9) SITE CONDITIONS PER EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. 1. FINAL ANTENNA CONFIGURATION SHOW ON THIS PLAN - SEE ANTENNA PLAN SHEETS FOR EIOSING AND TEMPORARY INTERIM CONFIGURATION. 2. E70S1NG TOWER INVENTORY PROVIDED BY OTHERS 3. ALL (N) ANTENNA, OOT, AND CABUNG WORK SHALL NOT COMMENCE UNTIL A SIGNED AND STALED STRUCTURAL TONER/POLE, SPRINT PLATFORM AND FOUNDATION REPORT IN ACCORDANCE WIH ALL APPLICABLE LOCAL, STATE. AND FEDERAL CODES MATOWG THE DESIGN DEPICTED ON 'MESE DRAWINGS HAS BEEN PROVIDED. 4. ALL (E) SPRINT' COAX CABLES AND ANTENNAS ARE TO BE REMOVED FRP/ THE 91E. 5. F PRESENT. ALL (9) REARWRE ANIMAS, MICROWAVE DISHES AND COAX CABLES TO BE RELOCATED (3) INSTALLED BELOW GUY TARES :. M. (1) PER SECTOR, (3) TOTAL FOR MOWING RRH'S/RRU'S ® Ia rvl r kintA -- ® I l (E) SPRINT RRU'S TO BE ((N) SPRINT1) PER CT500MHz TOTAL . ,I V S =I 4 1 4 w �� i y,RIII11� ELI RELOCATED, (1) PER SECTOR. (3) TOTAL 7I 4 . a', , 4. `'V 6. (N) SPRINT NV ANTENNAS ARE TO BE INSTALLED 50 THAT THE TOP OF THE (N) ANTENNA ALIGNS WITH THE TCP OF THE (E) SPRINT COMA ANTENNAS THAT ARE TO BE REMOVED. /ow 003 r SECTOR "C" \ SECTOR "B" ' p. MI: 31 pt& E i 4 -,or ,.,, iih, k (N) SPRINT 2500MHz R RH. •�� (1) PER SECTOR. (3) TOTAL TN MN 4t4", kirti nv (N) SPRINT 2500MHz ANIMA. (1) PER SECTOR. (3) TOTAL' Mn`), 'll (N) WARWIT 2500MHz RIM, (1) PER SECTOR (3) TOTAL �' NV ® (E) SPRINT RRU'S 70 BE RELOCATED. (1) PER SECTOR (3) TOTAL FINAL ANTENNA PLAN 3 NOTES NOT 4 ' 1 SCALE:lir --" ' Sprint' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY 8 CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO SPRINT IS STRICTLY PROHIBITED ,,, if ,,, smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007-6493 TEL: (425) 274-4444 FAX: (425) 274-4449 3 05-19-14 STRUCTURAL MODIFICATION 2 04-1614 100% CONSTRUCTION DRAWINGS 1 0240.14 90% CONSTRUCTION DRAWINGS 0 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD .Ivo B HC4 "r4z0 ,As� PROJECT INFORMATION: SPRINT 25 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: ENLARGED ANTENNA LAYOUT SHEET NUMBER: A 2 REV.: 3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS IN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF SMARTUNK, LLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROECTS WITHOUT THE WRITTEN AUTHORIZATION OF SMARTUNK, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE APPROVAL OF THE LICENSED PROFESSIONAL IN WRITING. (E) SPRINT ANTENNA (1) PER SECTOR, ((3) TOTAL - SEE SHEET A-2 (E )AL SPRINT BE RELOCATED ACTOR (3) (E) TOP OF UGHTNING ROD ELEV. 63'-2` AGL� (E) TOP OF MONOPOLE & TOP OF SPRINT ANTENNAS ELEV. 59'-2' ALLY _ �SPRNIT ANIMA RAD CENTER ELEV. 56'-2' ACL (E) TOP OF ROOF /6, 30'-0' ACL FINISH ELEV. 0-0 REF. EXISTING SOUTH ELEVATION 22'04' SCALE: 1/8' • 1'-0' 11nx1r SCALE: 1118'. r.' 8' 8' 4' 2' 0' 8' 1 (N) VALMONT CWT02-LL 7-1401NT5 (1) PER SECTOR. TOTAL OF (3) -SEE SHEET A-2 (N) SPRINT 2500MHz ANTENNA (1) PER SECTOR. (3) TOTAL - SEE SHEET A-2 EXISTING GUY WMRE:S (N) SPRINT 2500181z RRHI, (1) SEE SHEEEPER T AA -23) TOTAL (7) SPRINT ANTENNA (1) PER SECTOR. (3) TOTAL - SEE SHEET A-2 (E) RRU RELOCATED TO PER SECTOR TOTAL OF NEWS MOUNT. (E) TOP OF LIGHTNING ROD/6 ELEV. 6S-2' ACL (7) TOP CF MONOPOLE & TOP OF SPRINT ANTENNAS ELEV. 59'-2' ACL (N) SPRINT ANTENNA RAD CENTER ELEV. 56'-2' ACL (N) SPRINT RRH RAD CENTER ELEV. 48'-2' ALLY (7) TOP OF ROO ELEV. 30'-0' ACL L /4-0038' FINISH � 0 ELEV. 0' REF.'!" NEW SOUTH ELEVATION 22'x34 SCALE: 1/8' • 1'-0' 11'x1r SCALE: 1116". 1,0" 8' 8' 4' Y 0' 8' 2 Sprint' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY 8 CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO SPRINT IS STRICTLY PROHIBITED ,, .. smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007-6493 TEL: (425) 274-4444 FAX: (425) 274-4449 3 05.19-14 STRUCTURAL MODIFICATION 2 0416.14 100% CONSTRUCTION DRAWINGS 1 02.20.14 90% CONSTRUCTION DRAWINGS 0 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD •N9BN0 ..l2p6�3,4}rH PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: SOUTH ELEVATIONS SHEET NUMBER: A-3 REV.: 3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS N INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF SMAR1UNK, LLC AND ARE NOT TO 8E USED, N WHOLE OR 1N PART. FOR OTHER PROECTS WITHOUT THE WRITTEN AUTHORIZATION OF SMARTUNK, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE APPROVAL OF 71E UCENSED PROFESSIONAL IN WRITING. 0)051IN0 WY VARHS- EXISTING MONOPOLE (E) SPRINT ANTENNA (1) PER SECTOR, (3) TOTAL - SEE SHEET A-2 (0) TOP OF UGIINNG R00 ELEV. 63'-Y AOL (E) TOP OF MONOPOLE & TOP Cr SPRINT ANTENNAS EIEV. 59LY WILT (E) SPRINT ANTENNA RAD CENTER FLEV. 56'-Y AOL (E) TCP OF ROOF41 ELEV. 30'-0• ACL FINISH GRADE ELEV. 0'-0• REF. EXISTING EAST ELEVATION 22•634' SCALE:1H6' • 1'4' 1 rxir SCALE 1132• • 1'41' 16' 12' 6' 4' r 16' 1 (N) VALMONT CWTO2-LL T -MOUNTS (1) PER SECTOR TOTAL OF (3) - SEE SHEET A-2 (N) SPRINT 2500MHz ANTENNA (1) PER SECTOR, (3) TOTAL - SEE SHEET A-2 EXIS1ING GUY AIRES (N) SPRINT 25001111z RRH, (1) PER SECTOR (3) TOTAL - SEE SHEET A-2 EXISRNG MONOPOLE (0) SPRINT ANTENNA (1) PER SECTOR. (3) TOTAL - SEE SHEET A-2 (E) RRU RELOCATED TO NEW R5 MOUNT, (1) PER SECTOR TOTAL OF (3) (N) VALMONT R5 -LL UNIVERSAL PIPE MOUNT. (1) PER SECTOR TOTAL OF (3) INSTALLED BELOW GUY WINES - SEE SHEET A-2 (0) TOP OF UGHTNING ROOAN ELEV. 63'-2' AOL (E) TOP OF MONOPOLE & TOP OF SPRINT ANTENNAS ELEV. 59'-2• ACL _ (N) SPRINT ANTENNA RAD CENTER ELEV. 56'-2' ALLY (N) SPRINT RRH RAD CENTER ELEV. 46'-Y AGL (E) TOP OF ROOF ELEV. 30'-0" AOL 4 /quo CVO FNIDI WEE. ELEV. 0.-0. NEW EAST ELEVATION 22nar SCALE: 1,113" • 1'-0• 1r61r SCALE: 1H6' • 1'-0' 156551 8' 6' 4' 2' 0• 6' 2 Sprint THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS 15 PROPRIETARY 6 CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO SPRINT IS STRICTLY PROHIBITED /, ,6, smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007-6493 TEL: (425) 274-4444 FAX: (425) 274-4449 3 05.19.14 STRUCTURAL MODIFICATION 2 04.16-14 100% CONSTRUCTION DRAWINGS 1 02.20.14 90% CONSTRUCTION DRAWINGS 0 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD NvoBH0 A o. ten! 1 t>0248,144 AL' • PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: EAST ELEVATIONS SHEET NUMBER: A-4 REV.: 3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS IN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF SMARTUNK, LLC AND ARE NOT TO BE USED. IN WHOLE OR IN PART. FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF SMARTUNK, U.C. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRA)WNGS WITHOUT THE APPROVAL OF THE UCENSED PROFESSIONAL IN WRITING. I~ E70S11NG ANTENNA MINTING POLE (1YP) 0/W � �� IrG ` �.i # Y/1 I 14 ACIMET OUNIWIG ( ) NEW ANTENNA (TYP) NEW MOUNTING BRACKET (TTP) MANUFACTURER: MAW MODEL: ET-X-WM-18-65-8P WEXxif: 36.4 LHS DIMENSIONS: 61" X 12" X 4.3" FREQUENCY: REFER TO RF DATA SHEET t ' 4.3' 12 NOTES: 1. NEW ANTENNA TO BE MOUNTED TO 3"0 (NOM) SCH 40 PIPE MAST. CONTRACTOR TO VERIFY PIPE MAST SIZE AND SCHEDULE AND UPGRADE IF REQUIRED. 2. PROVIDE CROSSOVER PLATE KIT BY SITE PRO 1 OR APPROVED EQUAL, SIZE AS REQUIRED. 3. ANTENNA AND RRU CABLING TO BE CONNECTED PER EXISTING MONOPOLE NEW MOUNTING HARDWARE 9 12" STRUCTURAL MODIFICATION 2 04.16.14 ■ *" 1 02-2014 90% CONSTRUCTION DRAWINGS / / 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD .1xviBHoR1, 4t. ov �•Asii, c'.6)t t. — f PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY > . SHEET NUMBER: A 5 REV.: 3 RF DATA SHEET, PROVIDED BY RF ENGINEER. ANTENNA MOUNTING PIPE (SEE NOTE 1) \ -� NEW PANEL ANTENNA NEW PIPE MOUNT HARDWARE. CONTRACTOR SHALL USE ADEQUATE HARDWARE THAT FITS WITH AN EXISTING FRAME. * � �• •.l •• • • r It RF CONNECTOR, TYP RF CONNECTOR. TYP REMOTEI OTI ELECTRICAL TYP 1 1 ___1,_ —÷` NEW 12'-0JUMPER (TYP) NOTE ALL PIPES BRACKETS AND 195CELLANEOUS HARDWARE TOBE GALVAMZED OTHERWISE UNLESS NOTED NOMA INFORMATION PULLED FROM PREIINNARY PRODUCT DATA SHEET PRODUCT ESQ SDE TO T TO 2 2500MHz ANTENNA 6°C MOUNTING DETAIL 140T 1 REPLACE EXISTING MOUNTING PIPE WITH A 3•• PIPE. TYP. ,/ - l i i..4, �i % PROPOSED RRH MOUNTING KIT PROVIDED BY MANUFACTURER• TYP. � , ," / ny�`i,7 =.�jj Rte. i ' 1 RRH-V3 (2500MHz) DIMENSIONS UM PROPOSED RRH MOUNTING PROVIDED BY MANUFACTURER. KIT TYP. —• NEW CWT02-LL EXISTING NEW R5 -LL 1900 NEW STAINLESS STEEL HANGER RRU NEW 4" STAINLESS STEEL ART #31670-3 ORE ANP APPROVED .. ,. PROPOSED RRH, TYP. - EQUAL (TYP OF 2 PER //� BREAKOUT UNIT) t Lt:$ 2— NEW HYBRID FREQUENCY CABLE 'f5' +yi:::':'•:•`:? ;:4•:.. s 1 - �I J - -�i 1 m NEW 2500 RRH NEW HYBRID BREAKOUT UNIT. CONTRACTOR SHALL MOUNT WITH ADEQUATE TO EXISTINGFRAME. (TYP OF 1 PER SECTOR) NEW HYBRID FANOUT CABLE w.. REPLACE EXISTING MOUNTING s 111110hrl 1;,; WITH A 3"• PIPE. DIP._ E•♦ PIPE *. HAW,m: (15.5%18.6%9.45") WEIGHT: 59.5 lbs. WEIGHT W/BRACKET.7182 PIs . "REQUIRES 3"• PIPE ' FROM NEW RF CABINET (TYP OF 1 PER SECTOR) SUPPORT BY HOISTING GRIP EVERY 200' NEW RRU MOUNTING HARDWARE SUPPORT HYBRID CABLE WITHIN 12" OF BREAKOUT UNIT RRH MECHANICAL SPECS NOT TO °TT0 3 RRH MOUNTING TO 4 ANTENNA & RRH/RRU MOUNTING NOT TO 5 sNOT VALMONT PRODUCT PART CW?02-I I mar PRODIRCT PART / R5-11 (3 TOTAL) - `---1 (3 TOTAL) In '/- !!fir - %Ito QT�®��4k31{�� Y. ''T�y, . _ mac* \, \ `U .- `j 44 In 6 .., ,., MOUNT Nc OPnaNs: 1. IX RADAR FLIER 11/• 2. 2X BAKELITE 3. 4X INSULATION BUSHING 4. 4X BOLT: M8 X 25 , / 11'1 5. 4X WASHING:M8 6. 2X SCREW M12X 250 �" ' 7. 1X BRACKET - 8. 2X NUT: M12 4N 'R7 C7 T q - �" ,_ i� p • M m ( II 111 .. t/i/.0031 RADAR FILTER SPECS TO6 ANTENNA MOUNTING FRAME TO 7 RRH/RRU MOUNTING FRAME TO 8 st4sOT $°D� sNsOT Sprint• THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY 6 CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN AS R RELATES TO SPRINT IS STRICTLY PROHIBITED del smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007.6493 TEL: (425) 274-4444 FAX: (425) 274-4449 9 05-1014 STRUCTURAL MODIFICATION 2 04.16.14 100% CONSTRUCTION DRAWINGS 1 02-2014 90% CONSTRUCTION DRAWINGS 0 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD .1xviBHoR1, 4t. ov �•Asii, c'.6)t t. — f PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TIRE: DETAILS SHEET NUMBER: A 5 REV.: 3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS IN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF SMARTIJNK, LLC AND ARE NOT TO BE USED, IJ WHOLE OR IN PART, FOR OTHER PROJECTS NITHIXIT THE WRITTEN AUTHORIZATION OF SMARTUNK, U.C. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE APPROVAL OF THE LICENSED PROFESSIONAL IN WRITING. 1 Sprint General Site Information Site ID Market Region MLA Structure Type BTS Type Transmit Receive SEO3XC449 West Washington West ROOFTOP STANDARD 2496 Mhz - 2690 Mhz 2496 Mhz - 2690 Mhz Base Equipment BBU Kit BBU Kit Qty BBU Dimensions Growth Cabinet Growth Cabinet Qty Growth Cabinet Dimensions Growth Cabinet Weight RF Path Information RRH RRH Qty RRH Dimensions RRH Weight. lbs. RRH Mount Weight. Lbs. Powerand Fiber Cable Cable Qty Weight per foot. Lbs. Diameter. Inches. Length Ft. Coax Jumper Coax Jumper Qty Coax Jumper Length. Feet. Coax Jumper Weight Coax Jumper Diameter. Inches AISG Cable AISG Cable Qty AISG Diameter. Inches. AISG Cable length. Weight of entire AISG cable. Lbs. Antenna Sector Information RFOS Sheet Equipment Vendor Lattitude Longitude LL SITE ID Siterra SR Equipment type Equipment Vendor Samsung 47.5057 -122.290883 Outdoor Macro Samsung UADU 3.5" x 17.1" x 15.2" RRH-V3 3 15.5" x 18.6" x 7.48" 54 12.32 s Solution derived from existin( NA NA NA 69.6 27 8 TBD 0.5 Commscope ATCB•B01-006 3 0.315 8 1.3 Sector 1 Top Hat Top Hat Qty Top Hat Dimenstions Top Hat Weight (lbs) Incremental Power Draw needed by added Equipment 0 calculated as antenna height plus 20%) Sector 2 Sector 3 Antenna make/model KMW ET-X-WM-18-65-8P KMW ET-X-WM-18-65-8P KMW ET-X-WM-18-65-8P Antenna qty 1 1 1 Antenna Dimensions. Inches 61" x 12" x 4" 61" x 12" x 4" 61" x 12" x 4" Antenna Weight. Inches 36 36 36 Antenna Mounting Kit Weight. Lbs. -111b estimate. TBD. -11 Ib estimate. TBD. -11 Ib estimate. TBD. CL He fight 58 58 58 Antenna Azimuth 0 120 237 Antenna Mechanical Downtilt 0 0 0 Antenna etilt -2 -2 -2 U4 -Do 38 RF DATA SHEET NOT TO SCALE 1 Sprint' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY 8 CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN AS R RELATES TO SPRINT IS STRICTLY PROHIBITED ,e,, smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007-6493 TEL: (425) 274-4444 FAX: (425) 274-4449 3 05-19-14 STRUCTURAL MODIFICATION 2 04.16.14 100% CONSTRUCTION DRAWINGS 1 02-20-14 90% CONSTRUCTION DRAWINGS 0 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: RF DATA SHEET SHEET NUMBER: RF -1 REV.: 3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS IN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF SMARTUNK, LLC AND ARE NOT TO BE USED. IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHCRIZATON OF SMARTUNK, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE APPROVAL OF THE LICENSED PROFESSIONAL IN WRITING. if gEll- WOUNDING NOTFR, WOUNDING NOES,i 1. ALL DETAILS ARE SHOWN N GENERAL TERMS. 1. EXOTHERMIC WELDS (2). 2 AWG BARE TINNED SOLID 11. EXTEND TWO (2) /2 AWG TINNED CU CONDUCTOR ACTUAL INSTALLATION AND CONSTRUCTION MAY COPPER CONDUCTORS TO GROUNDING BAR. ROUTE FROM BURIED GROUNDING RING AND CONNECT TO LL VARY DUE TO STE SPECIFIC 2. GROUND ALL ANTENNA ASES. FRAMES, CABLE DE PARALLEL EXOTHERMIC.TO BURIED dNC RING AND REEPROPOSED TOWER. FOLLOW COMIA (DATIONS FOR GROUNDING CONNECTIONSN RUNS. AND OTHER METALLIC COMPONENTS USING 2. EC SHALL USE PERMANENT MARKER TO DRAW THE TO THE TOWER. (APPLICABLE TO NEW TOWERS). GROUND WIRES AND CONNECT TO SURFACE ONES BETWEEN EACH SECTION AND LABEL EACH 12. NUMBER OF GROUNDING BARS MAY VARY DEPENDING MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS SECTION CP', 'A', W. 11TH 1' HOCM LETTERS. ON THE TYPE OF (OWER, ANTENNA LOCATION, AND MANUFACTURER'S PRACTICES FOR GROUNDING 3. ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING CONNECTION ORIENTATION. THE SUBCONTRACTOR REQUIREMENTS GROUND COAX SHIELD AT BOTH LOCK WASHERS. COAT AU. SURFACES WITH AN SHALL 8E RESPONSIBLE FOR NSTALUNG ADDITIONAL ENDS AND EXIT FROM TOWER OR POLE USING MFR'S ANT -OXIDANT COMPOUND BEFORE MATING. ALL GROUNDING BARS AS REQUIRED. PROVIDING 50% PRACTICES S HARDWARE SHALL BE STAINLESS STEEL 3/8 INCH SPARE CONNECTION POINT 3. ALL GROUND CONNECTIONS SHALL BE EXOTHERMIC. DIAMETER OR LARGER. I3. EXPOSED GROUND WINES TO BE NON-METALLIC. ALL WIRES SHALL BE COPPER THHN/THWN. ALL 4. FOR GROUND BOND TO STEELONLY: INSERT A LIQUID TIGHT. GROUND WIRE SHALL BE GREEN INSULATED WIRE CADMIUM FLAT WASHER BEIYIEEN LUG AND S1EEL, ABOVE GROUND. COAT ALL SURFACES WITH AN ANT -OXIDANT _��- \ IOW c / �� ■ �� 1,; r. tV' �, !_ 1 'Q , r Y�tinn_". �'�"I •r% S . / 4. CONTRACTOR TO VERIFY AND TEST GROUND TO COMPOUND BEFORE MATING. SOURCE. GROUNDING AND OTHER OPERATIONAL5. NUT Nk WASHER SHALL BE PLACED oN THE FRONT LEGEND 3 1ESTING WILL BE WITNESSED BY SPRINT WIRELESS. SIDE OF THE GROUNDING BAR AND BOLTED ONLLC. REPRESENTATVE BACK SIDE INSTALL BUCK HEAT -SHRINKING TUBE 5. REFER TO DIVISION 16 GENERAL ELECTRIC: GENERAL 600 VOLT INSULATION/,4.fr ELECTRICAL PROVISION AND COMPLY IWTH AU. 1ERUINATONS. THE INTENT IS To WEATHERPROOF REQUIREMENTS OF GROUNDING STANDARDS. THE COMPRESSION CONNECTION. 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED 6. NUMBER OF GROUNDING BARS MAY VARY DEPENDING STANDARD NDDASIGN RD GROUNDINGOUMETH, AND RECEIPER VE CCOONNECTION OE►iTA O i. PROVIDE AS LOCATION, AND APPROVAL OF DESIGN BY AUTHORIZED SPRINT 7. GROUNDING KIT SHALL BE TYPE AND PART NUMBER ■ EXOTHERMIC CONNECTION • MECHANICAL CONNECTION o ANTENNA GROUND BAR M MASTER GROUND BAR 2 -' (N) SPRINT ANTENNA MOUNTING PIPE CONNECTED TO (E) ANTENNA GROUND BAR -1*_�. i_ y` _ , PIM i�11 MOBIUTY REPRESENTATIVE. PRIOR To INSTALLATION AS SUPPLIED OR RECOMMENDED BY CABLE OF GROUNDING SYSTEM. PHOTO DOCUMENT ALL MANUFACTURER. (N) SPRINT RRLN CONNECTED 10 \ = (E) ANTENNA GROUNDING BAR......DIFFICULTIES 0 -SITE 4+\ �r.�ei t i�:� EXOTHERMIC AND GROUND RING. 8. WEATHERPROOFING SHALL BE TYPE AND PART 7. NOTIFY CONSTRUCTION MANAGER IF /HERE ARE ANY NUMBER AS SJPPUED OR RECOMMENDED BY CABLE INSTALUNG GROUNDING SYSTEM DUE TO MANUFACTURER. SOIL CONDITIONS. 9. SUPPLED AND INSTALLED BY CONTRACTOR. 8. AEXISTING GROUND BARS. WINES & CONNECTIONS 10. WHEN NE SCOPE OF WORK REQUIRES THE ADDITION LL SHALL BE FIELD VERIFIED. ANY DEFICIENT ITEMS OF A GROUNDING BAR TO AN EXISTING TOWER. THE SHALL BE REPLACED AS REQUIRED TO ACHIEVE SUBCONTRACTOR SMALL OBTAIN APPROVAL FROM ADEQUATE GROUNDING REQUIRED BY. THE TOWER OWNER PRIOR TO MOUNTING THE NOTE: 1. CONTRACTOR TO REPLACE ALL MISSING GROUND BARS AND GROUNDING CONNECTIONS AS REQUIRED. REV. GROUNDING BAR 10 THE TOWER. ANTENNA GROUNDING PLAN DRAWN BY: JC CHECKED BY: VD 1 GROUNDING NOTES NOT TO 2 = SCALE ;;=$°GIAILLLEVM9=:;� -'• RRU GROUNDS STRANDED CU WIRE WITH GREEN, SIZE600V,AS THHN/THWN- INSULATION. SPECIFIED / #2 TINNED ANTENNA/RRU GROUND FROM MOUNTING PIPE HYBRID CABLE GROUND 1 ft NOTES: 1. DO NOT INSTALL CABLE DIRECT GROUND WIRE 2. WEATHER PROOFING AS SUPPLIED OR RECOMMENDED I , CONNECTOR WEATHERPROOFING KIT (TYP.) SEE NOTE 2 II' CONTRACTOR TO GROUND DOWN SHALL RRU , I tI �11,111 KIT AT A BEND AND ALWAYS TO ANTENNA GROUND BAR. BE ANDREWS. (TYPE & PART NUMBER BY CABLE MANUFACTURER.) TO ANTENNAS 1 SOROFPE3R LIFNEOUPENCY i l WEATHERPROOFING tI f/KIT(TYP.) STANDARD SOUND DET/3 E-5) lil ANTENNA CABLEf0��\ TO SMELTER (TMP.) /-ANTENNA GROUND AWG BAR, SIMILAR TO K16-057. MOUNT DEF DELIA TYPE ' ' 111. 99 �. GTTYPE GR riti III 1 GROUND BAR ON ANTENNA TOWER -13 TYPE HS TYPE HA J TIDE VS ME �•�� TYPE GL LUG 0 0 OOOOOOOO -• oOOOOOOO Q Q 4 0 0 0 O O O O O OO i EXISTING ex12'x1/4' THK.. TINNED GROUND BAR & CONNECTIONS. DEL2G TWO -HOLE LUG, BOLTED TO NOTE: GROUND BAR USING 3/8'-16 x 1 •PROVIDE NO -OX GREASE AT CONTACT 1/4'STAINLESS STEEL HEX HEAD SURFACE BETWEEN LUG AND GROUND BAR BOLTS AND HARDWARE. •CONTRACTOR WILL VERIFY BUSS BAR GROUNDING TO THE TOWER OR RING. VERIFY THAT THE 11.{11■1 GROUND BAR NEAR GROUND BAR IS TOP OF MONOPOLE. GROUNDED TO THE TOWER OR WAVEGUIDE TOWER OR RING LADDER. SECTOR GROUND BAR CONNECTIONS NOT TO 3 TYPICAL EXOTHERMIC WELD CONNECTIONS NscOT TO4 TYPICAL COAX GROUNDING NOT 5 E° STRANDED CU WIRE WITH GREEN, 600V. THHN/THWN INSULATION. *PROVIDE NO -OX GREASE AT CONTACT SIZE AS SPECIFIED SURFACE BETWEEN LUG AND GROUND BAR 12" TO 24" WINDOW INSPECTION REQUIRED FOR ALL INTERIOR BUTT CONDUCTOR EXTERNAL IN LA N UP TWO -HOLE AGAINST THE GROUND RAR ON WALL; FLOOR OR ON ANTENNA TOWER .-- -,COAX �-GROUND LEADS TO EACH SECTOR GROUND BAR= CABLE-...........- GROUND LEADS /--•/--•/-1, - --- --� '- '-CONNECTOR ANTENNA CABLE I - TOOTHEA. CONNECTOR 3/8'0x1 1/2' BARREL 1. 1/4" MIN WEATHERPROOFING KIT1 2 1/2'0 MAX S/S NUT S/S LOCK WASHER FLAT uml TUN WASHER MIN (SEE NOTE 3) �- 0 O ,___cgO O 0 O O 0 �{� O 0 O 0 O� 0\0_0 O 0 O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 Q OO �l� CJ 0 Q OO CJ 0 QO OO O O EXISTING-& CONNECTIONSO BAR CABLE GROUND KIT AWG STRANDED COPPER GROUND #6 WIRE (GROUNDED TO GROUND BAR) (S/S NOTE 1& 2) m CONNECTION OF CABLE GROUND KIT TO % 1 --_ --_ 41 ����� CLEAR HEAT ANTENNA CABLE SHRINK 1.1•11 1.1.1 TINNED COPPER LEAR • GROUND BARS AT OF TOWERS OR MONOPOLES SHALL USE EXOTHERMIC CONNECTION. TWO -HOLE LUG, BOLTED TO GROUND BAR USING 3/8'-16 x 1 1/4'57/UNLESS STEEL HEX HEAD BOLTS AND HARDWARE. ^WITH /2 SOLID TINNED BOTTOM OE EXOTHERMICEWIRE WELD LD STRANDED AWG WIRED WRH GREEN, X STRUCTURE, BUILDING, RING GROUND OR MGB 600V, THHN/THWN INSULATION TO ANTENNA VS to i i l - 0 0 ar NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT TWO -HOLE LUG. 3. WEATHER PROOFING SHALL INCORPORATE PPC WEATHERPROOFING TAPE KIT, COLD SHRINK SHALL NOT BE USED. WITH GROUNDING BAR MOW HEAT S/S FLAT WASHER SHRINK S/S BOLT (1 OF 2) *DO NOT DISCONNECT' TAG ON ALL GROUND BAR INTERCONNECTS AND EQUALIZERS TOWER MASTER GROUND BAR CONNECTIONS 6 CABLE GROUNDING 7 TWO HOLE LUG TO 8 SNOT CALE S Sprint' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO SPRINT ANY USE OR DISCLOSURE OTHER THAN ASR RELATES TO SPRINT IS STRICTLY PROHIBITED .. smartlink 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007-6493 TEL: (425) 2744444 FAX: (425) 274-4449 3 05.19.14 STRUCTURAL MODIFICATION 2 0416-14 100% CONSTRUCTION DRAWINGS 1 02-20-14 90% CONSTRUCTION DRAWINGS 0 02-19-14 90% CONSTRUCTION DRAWINGS REV. DATE REVISION DESCRIPTION DRAWN BY: JC CHECKED BY: VD PROJECT INFORMATION: SPRINT 2.5 SR 599 SE03XC409 10825 E MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY SHEET TITLE: GROUNDING PLAN & DETAILS SHEET NUMBER: G-1 REV.: 3 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS IN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF SMARTUNK, LLC AND ARE NOT TO BE USED IN WHOLE OR IN PART. FOR OTHER PRO.ECTS WITHOUT THE WRITTEN AUTHORIZATION OF SMARTUNK, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS VATHOUT THE APPROVAL OF THE UCENSED PROFESSIONAL IN WRITING.