Loading...
HomeMy WebLinkAboutPermit PL14-0042 - LES COOLEY / SAGE HILL PROFESSIONAL SERVICES - TYPE 1 WIRELESS TELECOMMUNICATIONS FACILITIES PERMITVERIZON SEA EAST ANDOVER 574 INDUSTRY DR PL14-0042 L14-0069 TYPE 1 WIRELESS City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director December 1, 2014 NOTICE OF DECISION TO: Les Cooley Sage Hill Professional Services/ Verizon Wireless 13630 SR 9 SE Snohomish, WA 98296 This letter serves as a notice of decision and is issued pursuant to TM 18.104.170 on the following project and permit approval. I. PROJECT INFORMATION Project File Number: L14-0069, PL14-0042 Applicant: Les Cooley, Sage Hill Professional Services (obo Verizon Wireless) Type of Permit Applied for: Type 1 Wireless Telecommunications Facilities Permit Project Description: Approval of a Type 1 Wireless Telecommunications Facilities Permit to add one 3' microwave dish at 66' centerline of an existing approved 70' monopole cell tower. No ground disturbance or expansion of the existing compound is proposed. Location: Parcel # 00223400010. This tower is located at 574 Industry Drive, Tukwila, WA 98188. The tower is located on the north side of the third building from the east. Associated Files: NA Comprehensive Plan Designation/ Zoning District: Tukwila Urban Center — Transit -Oriented Development Neighborhood (TUC — TOD) II. DECISION SEPA Determination: The City SEPA Responsible Official has previously determined that this application does not require a SEPA threshold determination because it is categorically exempt. Page 1 of 3 11/26/2014 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 FT, Decision on Substantive Permit: The City Community Development Department has determined that the application for a Type 1 Wireless Communications Facility does comply with applicable City and state code requirements and has approved that application with the following condition: 1. Install an emergency services shut down switch to power down antennas. III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code §18.104.010. Other land use applications related to this project may still be pending. No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to challenge either the conditions which were imposed by the MDNS decision or the failure of the Department to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing Examiner. A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in King County Superior Court from the Hearing Examiner's decision. IV. PROCEDURES AND TIME FOR APPEALING In order to appeal the Community Development Director decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14 days of the issuance of this decision. The requirements for such appeals are set forth in Tukwila Municipal Code ch. 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing party's behalf. 3. A statement identifying the decision being appealed and the alleged errors in the decision, including any specific challenge to an MDNS. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. 5. Appeal fee of $541 plus retainer. Page 2 of 3 11/26/2014 V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the Hearing Examiner based on the information presented to the Community Development Director, who made the original decision. No new evidence or testimony will be permitted during the appeal hearing. Parties will be allowed to present oral argument based on the information presented to the Community Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is the City's final decision. Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW ch. 36.70C. An appeal challenging a DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the subject property. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Laura Benjamin, who may be contacted at 206-433-7166 or via email at laura.benjamin@tukwilawa.gov for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. Department of Community Development City of Tukwila Page 3 of 3 11/26/2014 .., a ofId�`' Department Of Community Development AFFIDAVIT OF DISTRIBUTION I, Laura Benjamin , HEREBY DECLARE THAT: Associated File Number (s): L14-0069 Notice of Application X Notice of Decision Notice of Public Hearing Notice of Public Meeting Determination of Non- Significance Mitigated Determination of Non - Significance Determination of Significance & Scoping Notice Short Subdivision Agenda Notice of Application for Shoreline Mgmt Permit Shoreline Mgmt Permit Board of Appeals Agenda Packet Board of Adjustment Agenda Packet Official Notice Notice of Action Other: Was mailed to each of the addresses listed/attached on this 26 day of November, 2014 Project Name: Verizon Sea East Andover Project Number: PL14-0042 Associated File Number (s): L14-0069 Mailing requested by: Laur Benjamin Mailer's signatur : ---.-� W:\USERS\LAURA\WIRELESS FACILITIES\L14 0069\L14-0069 NOD AFFIDAVIT OF DISTRIBUTION.DOC Les Cooley Sage Hill Professional Services/Verizon Wireless 13630 SR 9 SE Snohomish, WA 98296 W:\USERS\LAURA\WIRELESS FACILITIES\L14 0069\L14-0069 NOD AFFIDAVIT OF DISTRIBUTION.DOC SAGE HILL professional services October 29, 2014 City of Tukwila Department of Community Development 6300 Southcenter Blvd. Tukwila, WA 98188 RE: 574 Industry Drive, Type 1 Description RECEIVED OCT 3 0 2014 COMMUNI I Y DEVELOP MENT The proposal is to add 3' microwave dish at 66' centerline of existing approved 70' monopole cell tower. The microwave dish will not exceed the height of existing structure and is exempt from SEPA per section 6, ii of checklist. The addition of 3' microwave dish is in compliance with City code per Type 1 requirements. If you have any question please contact me. Sincerely, Les Cooley Consultant for Verizon Wireless Northwest Office: 13630 SR 9 SE, Snohomish, WA 98296 / les@sage-hill.com / 425-530-2945 STATE OF WASHINGTON COUNTY OF KING CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY ss RECEIVED OCT 302014 C(A41;fU1v1l Y t)LVLLOPMI=NT The undersigned being duly sworn and upon oath states as follows: I. 1 am the current &erne@ of the property which is the subject of this application. 2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my knowledge. 3. The application is being submitted with my knowledge and consent. MAna « "1494rf 4. grants the City, its employees, agents, engineers, contractors or other representatives the right to enter upon Owne 's real property, located at 5-66 r"J v$tr/ Ort vt for the purpose of application review, for the limited time necessary t6 complete that purpose. 5. greleargrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City. 6. Non -responsiveness to a City information request for ninety (90) or more days, shall be cause to cancel the application(s) without refund of fees. EXECUTED at 6 17 11 n J IJS.Y-y Or6,4 ,4 (city), L✓4 (state), on 0 CT • -' , 20 I Ross iS'eoKk,y (Print Name) l 617 I', Jt rrcy Ai. (Address)dd6 - 5 75 _ 6675 (Phone Number) rJt<L 1q wA Rpt ;g (Signature On this day personally appeared before me goSS eckiv to me known to be the individual who executed the foregoing instrument and acknowledged that he/she signed the saAe as his/her voluntary act and deed for the uses and purposes mentioned therein. SUBSCRIBED AND SWORN TO BEFORE ME ON THIS LESTER C COOLEY Notary Public State of Washington My Commission Expires June 24, 2018 2q DAYIOF )`0 ,20 NOTARYPUBLI in and for the State of V>Srashington A residing at ,frtD A. My Commission expires on 6 L' " e24 / g \\deptstorelCity Common\Teri\Rcvisions In ProgresslWireless Communication Facility-Jan2011.docx CITY OF TUKWILA Department of Community Deve 6300 Southcenter Boulevard, Tukwila, Telephone: (206) 431-3670 WIRELESS TELE- IVEQOMMUNICATION OCT 21 2014 FACILITIES COMMUNI I Y DEVELOPMENT APPLICATION FOR STAFF USE ONLY Permits Plus Type: P -WIRE Planner: File Number: L' y — 00 ci Application Complete Date: Project File Number:T/ / ( {[� Vi;=? Application Incomplete Date: Other File Numbers: NAME OF PROJECT/DEVELOPMENT: Sea East Andover BRIEF DESCRIPTION OF PROJECT: Add 3' microwave dish to existing 70' monopole cell tower CIRCLE TYPE - ■ TYPE 1 TYPE 2 TYPE 3 (PUBLIC HEARING NOTICE ROD) LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. 574 Industry Drive LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). 0223400010 DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City, to whom all notices and reports will be sent. Name: Les Cooley for Verizon Wireless Address: 13630 SR 9 SE, Snohomish, WA 98296 Phone: (425) 530-2945 FAX: (360) 668-4325 Date: 10 + 2 — IC( \\deptstore\City Common\Teri\Revisions In Progress\Wireless Communication Facility-Jan201 I.docx SHEET INDEX 1 11\11IE ��ee ®c` ' UNE NC l'• VerIn co in CD �� i SAGE HILL professional services ARCHITECTURAL T-1 TITLE SHEET SP-1 GENERAL NOTES A-1 OVERALL SITE PLAN A-2 ENLARGED SITE AND ANTENNA PLANS A-3 ELEVATIONS ELECTRICAL 1 GROUNDING PLAN AND DETAILS WASHINGTON STATE CODE COMPLIANCE. vr I I �.r/lessNI SEA- EAST ANDOVER (M W ADD) 574 INDUSTRY DRIVE TUKWILA, WA 98188 LAT: 47° 27' 15.36" N LONG:122° 14' 55.44" W CONFIDENTIAL AND PROPRIETARY ELEVATION 25.0' AM S L Not for disclosure outside VERIZON WIRELESS 1 y _ ria G y without permission. WAC 51-502012 IMC, STANDARDS AND AMENDMENTS, WAC 51-52 2012 IFC, STANDARDS AND AMENDMENTS, WAC 51-54 2012 UPC, STANDARDS AND AMENDMENTS, WAC 51-56, 51-57 SEA- EAST ANDOVER (MW ADD) 574 INDUSTRY DRIVE TUKWILA, WA 98188 PROJECT SUMMARY APPLICANT. 324WIRELESS 32455 1 158TH AVE SE, MS 231 BELLEVUE, WA 98008 APPLICANT AGENT. SAGE HILL, LLC CONTACT: LESTER COOLEY PHONE: 425-530-2945 EMAIL: LESCOSAG®SAGE-HILL.COM DESIGN CONSULTANT. OC CAMP ASSOCIATES CAMP Sc ASSOCIATES INC. 19401 40TH AVE W, SUITE 304 LYNNWOOD, WA 98036 CONTACT: ERIC CAMP PHONE: 425-740-6392 email: eric.camp®campassoc.com LEGAL DESCRIPTION. TBD SITE NAME. SEA EAST ANDOVER SITE ADDRESS. 574 INDUSTRY DRIVE TUKWILA, WA 98188 LAND OWNER. NCWP ANDOVER EXECUTIVE PARK STRUCTURE OWNER. VERIZON WIRELESS JURISDICTION. CITY OF TUKWILA PARCEL NUMBER. 0223400010 ZONING. TUC (TUKWILA URBAN CENTER) OCCUPANCY. GROUP - U (UNOCCUPIED) CONSTRUCTION TYPE. II-B PROJECT DESCRIPTION. 1�LYNNWOO5)280-86 36 304 CELL: (OD, ,69803 51 FAX: (425) 252-2860 W W W.CAMPASSOC.COM PROJECT MANAGER. EJC PREPARED BY. Alo SIGNATURE BLOCK VICINITY MAP APPROVED BY. EJC TITLE SIGNATURE DATE T.U4IALV.I.1 411114 ' - 3W nth 51 -- CO MANAGERON res++ T� 1k1°r'x �SITE 10-29-I4 1551gD FOR FM& PEWIT e. .. LIM PERMIT RF ENGINEER ?„ rw.d. I Redden 77 % REGISTERED ARCHI ECT / �UL NI ATE OF ASHINGT9�1 10/29!2011 REAL ESTATE a - s °�°u1°` Blvd 1 ' T �"�� "Mgr NAME SITE ACQUISITION Upland � I NORTH TITLE SHEET DRIVING DIRECTIONS FROM VERIZON WIRELESS (3245 158TH AVE. SE. BELLEVUE WA): THE SCOPE OF WORK INCLUDES: THIS PROPOSAL IS FOR THE INSTALLATION OF (1) NEW 3'-0" MICROWAVE ANTENNA DISH AT DESIGNATED HEIGHT ON AN EXISTING MONOPOLE PROPERTY OWNER DEPART 3245 158TH AVE SE, BELLEVUE, WA 98008 ON 158TH AVE SE (SOUTH-WEST) TURN RIGHT (WEST) ONTO SE EASTGATE WAY AND TURN LEFT (WEST) ONTO RAMPI-90 W / SEATTLE TAKE RAMP (LEFT) ONTO 1-90 [MOUNTAINS TO SOUND GREENWAY-I-90] AT EXIT 10, TURN RIGHT ONTO RAMP 1-405 S / 1-405 N / BELLEVUE / EVERETT / RENTON / TACOMA SHEET NUMBER T1.0 TOWER OWNER TAKE RAMP (LEFT) ONTO 1-405 1-405 S / TACOMA / RENTON AT EXIT 1, TURN RIGHT ONTO RAMPWA-181 S / W. VALLEY HWY. / TUKWILA TURN RIGHT (EAST) ONTO INTERURBAN AVE S ANDROAD NAME CHANGES TO WA-181 [W VALLEY HWY] TURN RIGHT (WEST) ONTO STRANDER BLVD AND TURN LEFT (SOUTH) ONTO ANDOVER PARK E TURN LEFT (EAST) ONTO INDUSTRY DR AND ARRIVE NEAR TUKWILA PROJECT NUMBER 20141001203 CONTRACTOR NOTES. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO THE SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. GENERAL NOTES. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, AND THIS SET OF PLANS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANYTHING ELSE DEEMED NECESSARY TO COMPLETE INSTALLATIONS AS DESCRIBED HEREIN. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE NEW PROJECT, WITH THE CONSTRUCTION AND CONTRACT DOCUMENTS, FIELD CONDITIONS AND CONFIRM THAT THE PROJECT MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY ERRORS, OMISSIONS, OR DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/ VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. ALL WORK PERFORMED ON PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. THE STRUCTURAL COMPONENTS OF THIS PROJECT SITE/FACILITY ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. ANTENNA SUPPORTING POLE I5 UNDER A SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION SUB -CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS. ERECTION SUB -CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF PERSONNEL AND PROPERTY FROM HAZARDOUS EXPOSURE TO OVERHEAD DANGERS. GENERAL CONTRACTOR SHALL PROVIDE AT THE PROJECT SITE A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR THE USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. DETAILS INCLUDED HEREIN ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS OR SITUATIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE SCOPE OF WORK. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION UPON COMPLETION OF WORK. CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. CONTRACTOR SHALL ENSURE THE GENERAL WORK AREA IS KEPT CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY, PREMISES SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, REGULATIONS AND SAFETY REGULATIONS, ALL OSHA REGULATIONS, ALL PUBLIC AND MUNICIPAL AUTHORITIES, AND ANY UTILITY COMPANIES' REGULATIONS AND DIRECTIVES. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE SCOPE OF WORK. EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. THE CONTRACTOR IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT ANY AND ALL DISCREPANCIES TO REPRESENTATIVE. ANY MINOR ERRORS AND OMISSIONS IN THE DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE TRAYS AND ELECTRICAL LINES AND ANTENNA MOUNTING. VERIFICATION THAT EXISTING TOWER/POLE/STRUCTURE CAN SUPPORT THE PROPOSED ANTENNA, COAX & ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. SPECIAL INSPECTIONS. SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 110 AND 1704 SHALL BE PERFORMED (A5 REQUIRED) BY A QUALIFIED TESTING AGENCY APPROVED BY THE ARCHITECT. INSPECTION AGENCY SHALL BE RETAINED BY THE PROJECT OWNER OR THEIR RESPONSIBLE CHARGE. THE ARCHITECT, ENGINEER OF RECORD, AND BUILDING DEPARTMENT SHALL RECEIVE COPIES OF ALL INSPECTION AND TEST RESULTS. REFER TO DOCUMENTS FOR SPECIFIC INFORMATION. 1 GENERAL NOTES CIVIL NOTES. 1. ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS AND STIPULATED IN THE SPECIFICATION PROJECT SUMMARY. 2. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 3. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE PCS EQUIPMENT, TOWER AREAS, AND ADJACENT BUILDINGS. 4. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS. SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 5. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO THE CRUSHED STONE APPLICATION. $UBGRADE AND BASE PREPARATION. 1. FOR SLAB -ON -GRADE CONSTRUCTION IT WILL BE NECESSARY TO OVEREXCAVATE THE SITE BY 2'-0" AND IMPORT AN APPROVED GRANULAR FILL. THE FILL SHALL BE COMPACTED TO AT LEAST 95% OF THE MAXIMUM DRY UNIT WEIGHT WITH A MOISTURE CONTENT WITHIN 2% OF THE OPTIMUM MOISTURE CONTENT AS DETERMINED BY THE MODIFIED PROCTOR TEST (ASTM D-1557).COMPACTION REQUIREMENTS APPLY TO BACKFILL FOR UTILITY TRENCHES AND FOUNDATION EXCAVATIONS WITHIN STRUCTURES, DRIVEWAYS, OR PARKING LOT AREAS. 2. COMPACTION SHALL BE ACCOMPLISHED BY PLACING THE FILL IN SUCCESSIVE, HORIZONTAL, APPROXIMATELY SIX- TO EIGHT -INCH LOOSE LIFTS AND MECHANICALLY COMPACTING EACH LIFT TO AT LEAST THE SPECIFIED MINIMUM DRY DENSITY. 3. ANY ORGANIC MATERIAL, DELETERIOUS MATERIAL OR DISTURBED SOIL SHALL BE REMOVED FROM FLATWORK AREAS. 4. THE GROUND SURFACE SURROUNDING EXTERIOR STRUCTURES SHALL BE SLOPED TO DRAIN AWAY IN ALL DIRECTIONS. CONCRETE NOTES. 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH A.C.I. 301, A.C.I. 318 AND THE SPECIFICATION CAST -IN-PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, ALL CAST -IN-PLACE CONCRETE SHALL BE NORMAL WEIGHT, AIR -ENTRAINED CONCRETE WITH A MINIMUM COMPRESSIVE STRENGTH OF 2500 POUNDS PER SQUARE INCH AT 28 DAYS. TYPE I-11 PORTLAND CEMENT WILL BE USED WITH A MAXIMUM AGGREGATE SIZE OF 3/4" AND 6% ±1% AIR ENTRAINMENT. ALL CONCRETE WILL HAVE A MAXIMUM WATER/CEMENT (W/C) RATIO OF 0.48. 3. ALL CONCRETE FLATWORK SHALL HAVE A STIFF BROOM FINISH AND HAVE A SLOPE OF 1/8" PER FOOT UNLESS NOTED OTHERWISE. 4. REINFORCING BARS SHALL BE NEW BILLET STEEL CONFORMING TO A.S.T.M. A615, GRADE 60, DEFORMED. 5. DETAIL, FABRICATE AND ERECT REINFORCEMENT BARS, INCLUDING BAR SUPPORTS, SPACERS, ETC. IN ACCORDANCE WITH "DETAILING OF CONC. REINFORCEMENT" (A.C.I. 315-80, REV. 1986). 6. UNLESS OTHERWISE NOTED, ALL LAP SPLICES SHALL BE CLASS B CONFORMING TO ACI 318-95. 7. A CHAMFER OF 1" SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE IN ACCORDANCE WITH A.C.I. 301 SECTION 4.2.4 UNLESS OTHERWISE NOTED. 8. CONCRETE WORK SHALL BE COORDINATED WITH THE MECHANICAL, EQUIPMENT, AND ELECTRICAL WORK TO ASSURE THAT ALL AFFECTED PIPES, CONDUITS INSERTS, ETC. ARE IN PLACE AND VERIFIED BEFORE PLACING CONCRETE. 9. CONCRETE COVER FOR REINFORCING BARS SHALL CONFORM TO THE FOLLOWING UNLESS INDICATED OTHERWISE ON THE DRAWINGS: -CONCRETE EXPOSED TO WEATHER OR IN CONTACT WITH GROUND - -CONCRETE CAST AGAINST EARTH - 2 INCHES 3 INCHES 10. COORDINATE LOCATION OF STEEL ANCHOR BOLTS WITH STEEL FABRICATOR PRIOR TO INSTALLATION IN FIELD. 11. CONTRACTOR SHALL PROVIDE SLEEVES FOR ALL WALL/SLAB PENETRATIONS (PIPING, CONDUIT,ETC.) POWER, TELCO AND COAX TO ENTER SITE UNDER EQUIPMENT SLAB. z_Nit/wocio y METAL NOTES. PART 1 - GENERAL 1. SECTION INCLUDES: STRUCTURAL STEEL FRAMING MEMBERS, BASE PLATES, PLATES, BARS AND GROUTING UNDER BASE PLATES. 2. SUBMITTALS: SHOP DRAWINGS: INDICATE SIZES, SPACING, AND LOCATIONS OF STRUCTURAL MEMBERS, OPENINGS, CONNECTIONS, CAMBERS, LOADS, AND WELDED SECTIONS. 3. QUALITY ASSURANCE A FABRICATE STRUCTURAL STEEL MEMBERS IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. B. PERFORM DESIGN UNDER DIRECT SUPERVISION OF A PROFESSIONAL STRUCTURAL ENGINEER LICENSED IN THE STATE. PART 2 - PRODUCTS 1. MATERIALS: A. STRUCTURAL STEEL MEMBERS: ASTM A572, GRADE 50 B. STRUCTURAL TUBING: ASTM A500, GRADE B C. PIPE: ASTM A53, TYPE E OR S, GRADE B D. BOLTS, NUTS, AND WASHERS: ASTM A325 E. ANCHOR BOLTS: ASTM A307 F. WELDING MATERIALS: AWS D1.1, TYPE REQUIRED FOR MATERIALS BEING WELDED G. GROUT: NON -SHRINK TYPE, PREMIXED COMPOUND CONSISTING OF NONMETALLIC AGGREGATE, CEMENT, WATER REDUCING AND PLASTICIZING ADDITIVES, CAPABLE OF DEVELOPING A MINIMUM COMPRESSIVE STRENGTH OF 7000 psi AT 28 DAYS. H. SHOP AND TOUCH-UP PRIMER: SSPC 15, TYPE 1, RED OXIDE I. TOUCH-UP PRIMER FOR GALV. SURFACES: ZINC RICH TYPE 2. FABRICATION: CONTINUOUSLY SEAL JOINTED MEMBERS BY CONTINUOUS WELDS. GRIND EXPOSED WELDS SMOOTH. 3. FINISH: A. PREPARE STRUCTURAL COMPONENT SURFACES IN ACCORDANCE WITH SSPC SP -1 TO SP -10 PROCEDURES. B. STRUCTURAL STEEL MEMBERS SHALL BE HOT DIPPED GALVANIZED. PART 3 - EXECUTION 1, EXAMINATION AND PREPARATION: VERIFY THAT THE FIELD CONDITIONS ARE ACCEPTABLE. 2. ERECTION: A. ALLOW FOR ERECTION LOADS. PROVIDE TEMPORARY BRACING TO MAINTAIN FRAMING IN ALIGNMENT UNTIL COMPLETION OF ERECTION AND INSTALLATION OF PERMANENT BRIDGING AND BRACING. 8. FIELD WELD COMPONENTS INDICATED ON SHOP DRAWINGS. C. DO NOT FIELD CUT OR ALTER STRUCTURAL MEMBERS WITHOUT APPROVAL OF THE ARCHITECT/ENGINEER. D. AFTER ERECTION, TOUCH-UP WELDS, ABRASIONS, AND SURFACES NOT SHOP PRIMED OR GALVANIZED WITH TOUCH-UP PRIMERS AS SPECIFIED UNDER SECTION 05000, -METALS, PART 2 - PRODUCTS, H & I. SURFACES TO BE IN CONTACT WITH CONCRETE NOT INCLUDED. 3. FIELD QUALITY CONTROL: FIELD INSPECTION OF MEMBERS, CONNECTIONS, WELDS AND TORQUING. TELECOMMUNICATIONS WIRING COMPONENTS (COAXIAL ANTENNA CABLE) GENERAL A. ALL MATERIALS, PRODUCTS OR PROCEDURES INCORPORATED INTO WORK SHALL BE NEW AND OF STANDARD COMMERCIAL QUALITY. B. CERTAIN MATERIALS AND PRODUCTS WILL BE SUPPLIED BY THE OWNER (REFER TO GENERAL CONDITIONS FOR THE LIST OF OWNER FURNISHED EQUIPMENT, MATERIALS AND SUPPLIES FOR THESE ITEMS). THE CONTRACTOR I5 RESPONSIBLE FOR PICKUP AND DELIVERY OF ALL SUCH MATERIALS C. ALL OTHER MATERIALS AND PRODUCTS SPECIFIED IN THE CONTRACT DOCUMENTS SHALL BE SUPPLIED BY THE CONTRACTOR. 2. MATERIALS: A. COAXIAL CABLE: 1. INSTALL COAXIAL CABLE AND TERMINATIONS BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS WITH COAXIAL CABLES SUPPORTED AT NO MORE THAN 3'-0" 0.C. WEATHERPROOF ALL CONNECTORS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURERS' REQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OF EQUIPMENT LOCATION UNLESS OTHERWISE STATED. 2. ALL COAX RUN LENGTHS GREATER THAN 143 FEET SHALL BE 1-5/8" AND IN LENGTH LESS THAN OR EQUAL TO 143 FEET SHALL BE 7/8". 3, ANTENNA AND COAXIAL CABLE GROUNDING A. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF COAXIAL CABLE (NOT WITHIN BENDS) COAXIAL CABLE IDENTIFICATION A. TO PROVIDE EASY IDENTIFICATION AND UNIFORM MARKING OF ANTENNA CABLING, PLASTIC TAGS SHALL BE USED AT THE FOLLOWING LOCATIONS: 1. FIRST LOCATION IS AT THE END OF THE COAX NEAREST THE ANTENNA (WHERE THE COAXIAL CABLE AND JUMPER ARE CONNECTED). 2. SECOND LOCATION IS INSIDE THE EQUIPMENT SHELTER NEAR THE WAVEGUIDE ENTRY PORT. B. USE ANDREW CABLE TIES (PT.# 27290) TO SECURE IDENTIFICATION TAGS. TESTING VERIZON WIRELESS SHALL PROVIDE AN INDEPENDENT TESTING AGENCY TO PERFORM THE COAXIAL SWEEP TEST & REPORT. THE CONTRACTOR IS TO PROVIDE CLIMBER / QUALIFIED PERSONNEL TO ASSIST IN ANY REPAIRS AND WEATHERPROOFING ONCE THE TEST IS COMPLETE. THE CONTRACTOR IS TO PROVIDE VERIZON WIRELESS A MINIMIM OF 48 HOURS NOTICE PRIOR TO THE TIME OF THE SWEEP TEST. ELECTRICAL NOTES. INSTALLATION OF SECONDARY POWER AND CONNECTION TO METER SHALL BE COMPLETED IN COMPLIANCE WITH NATIONAL ELECTRIC CODE, NFPA 70, AND THE STATE LAWS, RULES AND REGULATIONS FOR INSTALLING ELECTRIC WIRES & EQUIPMENT, ALL LATEST ISSUE, AND WITH SPECIFICATIONS PER A.S.T.M. B 231, B 400, I.C.E.A. S651-401, I.C.E.A. P81-570, & LOCAL PUD. PROVIDE A METER BASE PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE OF OWNER FURNISHED BACK BOARD. UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40, TYPE 1, CONFORMING TO UL ARTICLE 651: WESTERN PLASTICS OR CARLON MANUFACTURER. COUPLINGS SHALL BE SLIP-ON, SOLVENT SEALED T PIPE: SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC DUCT. ALL BENDS SHALL BE "WIDE SWEEP" TYPE WITH A 24" MINIMUM RADIUS. ALL CONDUIT UNDER ROADS SHALL BE RG5, (OR PVC ENCASED IN 8"x18" RED CONCRETE DUCTBANK). CONDUIT USED INDOORS SHALL BE E.M.T., AND RIGID GALVANIZED STEEL FOR OUTDOORS. COUPLINGS SHALL 8E RIGID STEEL AND COMPRESSION TYPE FOR E.M.T. SET SCREW FITTINGS ARE NOT PERMITTED. FOR ALL STUBS -UPS, USE RIGID GALVANIZED STEEL CONDUIT. WIRE AND CABLE SHALL BE OF THE TYPE AND SIZE AS REQUIRED BY NEC. THERE WILL BE NO SPLICES ALLOWED. PROVIDE HDPE PULLING HAND HOLES AS NEEDED. CONTRACTOR SHALL PROVIDE TEST OF THE GROUNDING SYSTEM BY CERTIFIED TESTING AGENT. PROVIDE INDEPENDENT TEST RESULTS TO THE PROJECT MANAGER FOR REVIEW. GROUNDING SYSTEM RESISTANCE TO GROUND SHALL NOT EXCEED 5 OHMS. ALL ABOVE GRADE INTERIOR GROUNDING CONNECTORS SHALL BE DOUBLE -LUG COMPRESSION TYPE. ALL BELOW GRADE AND EXPOSED EXTERIOR GROUNDING CONNECTIONS TO PERMANENT EQUIPMENT AND FIXED BUILDING ELEMENTS SHALL BE CADWELD TYPE. CARE SHALL BE TAKEN TO REVIEW CONNECTION LOCATIONS AND MATERIAL TYPES TO AVOID POSSIBLE GALVANIC CORROSION. ALL EXPOSED GROUNDING CONNECTIONS TO BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS "NO -OXY", "NOAOLX" OR "PENETROX". VERIFY PRODUCT WITH PROJECT MANAGER. ALL BOLTS, WASHERS AND NUTS USED ON GROUNDING CONNECTIONS SHALL BE STAINLESS STEEL. ALL EXTERIOR GROUND BARS SHALL BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS LPS-3 OR AS PER NOTE 6 ABOVE. ALL JUNCTION AND OUTLET BOXES TO BE LABELED WITH KROY TAPE, OR EQUAL, DESIGNATING ALL CIRCUIT NUMBERS CONTAINED IN EACH BOX. CONTRACTOR TO ENSURE ILC PROVIDED WITH (2) INTERNAL 'PISS. CONTRACTOR SHALL COORDINATE WITH SITE SURVEY TO LOCATE EXISTING UNDERGROUND UTILITIES. WHEREVER POTENTIAL CONFLICTS/ INTERFERENCES EXIST, HAND EXCAVATE TO AVOID DAMAGE. CONTACT ALL UTILITIES TO LOCATE UNDERGROUND PIPING IN PUBLIC ROW. VERIFY THATA.I.C. OF THE UTILITY DOES NOT EXCEED THE A.I.C. RATING OF THE PROVIDED C EQUIPMENT SHELTER PACKAGE. IF OVER 10KAIC, PROVIDE FUSIBLE SERVICE ENTRANCE SWITCH AND CONFIRM LOWERING OF AIC TO ACCEPTABLE LEVELS. UTILITY POINTS OF SERVICE AND WORK / MATERIALS SHOWN ARE BASED UPON PRELIMINARY INFORMATION PROVIDED BY THE UTILITY COMPANIES AND ARE FOR 81D PURPOSES ONLY. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK / MATERIALS REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY ENGINEERING PLANS AND SPECIFICATIONS ONLY. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL ROPES, CABLES, PULL BOXES, CONCRETE ENCASEMENT OF CONDUIT (IF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE RISERS, TRENCHING, BACKFILL, PAY ALL UTILITY COMPANY FEES AND INCLUDE ALL REQUIREMENTS IN SCOPE OF WORK. GROUNDING NOTES. 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EOUIPM ENT IS NOT BLOCKED. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 4. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). 5. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING TWO (2) HIGH PRESS CRIMPS. 6. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. 7. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 8. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG TIN PLATED COPPER UNLESS OTHERWISE INDICATED. 9. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, 5/8"0 10 -FT LONG (OR NOTED OTHERWISE ON PLANS), AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18" BELOW FINAL GRADE OR 6" BELOW FROST LINE FOR MAXIMUM DEPTH. 10. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. cn 1 SAGE HILL professional servIcEs SEA - EAST ANDOVER (MW ADD) 574 INDUSTRY DRIVE TUKWILA, WA 98188 CAMP+ ASSOCIATES 19401 40TH AVE W., SUITE 304 LYNNWOOD, WA 98036 CELL: (425) 280-8651 FAX: (425) 252-2860 W W W.CAMPASSOC.COM PROJECT MANAGER. EJC PREPARED BY. AIO APPROVED BY. EJC 10-29-14 ISSUED FOR FINAL PERMIT 10-28-14 ISSUED FOR PRELIM PERMIT REGISTERED ARCHI ECT 11. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDE 45' BENDS CAN BE ADEQUATELY SUPPORTED. 12. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM BELOW THE FROST LINE. 13. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0" FROM EQUIPMENT CONCRETE PAD, SPREAD FOOTING, OR FENCE. 14. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED SPRAY. 15. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING 16. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM) 17. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. 18. CONTRACTOR TO VERIFY CURRENT GROUNDING STANDARDS PRIOR TO CONSTRUCTION. TE OF ASHINGT 10/79/7014 GENERAL NOTES SHEET NUMBER SP -1 PROJECT NUMBER 20141001203 N ADJACENT ZONING: TUC EXISTING BUILDING EN PQNK Eo 0 a (E) BUILDING -? (E) TRAIN TRACKS, TYP. ADJACENT ZONING: TUC GENERAL NOTES: 1. THIS IS NOT A SURVEY, ALL PROPERTY BOUNDARIES, ORIENTATION OF TRUE NORTH AND STREET HALF WIDTHS HAVE BEEN OBTAINED FROM A TAX PARCEL MAP AND ARE APPROXIMATE. 2. REFER TO PAGES T-1 AND SP -1 FOR MORE INFORMATION. 3. DIG NOTE: CAUTION CALL BEFORE YOU DIG! BURIED UTILITIES EXIST ON THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. (E) INGRESS / EGRESS zV _2 g r 4E) BUILDINGS (E) INGRESS / EGRESS TAX ID: 0223400010 AREA: ±4.08 ACRES ZONING: TUC PROPERTY LINE 3302' MUSIJ LJ DR. OVERALL SITE PLAN ADJACENT ZONING: TUC N ROA • (E) VERIZON WIRELESS PROJECT AREA ADJACENT ZONING: TUC 4E) BUILDING-? (E) INGRESS / EGRESS -NE LIV-0049 .rseee ur iebeve were, r. ua Da • F SITE 2 VICINITY MAP NOT TO SCALE TBD 3 LEGAL DESCRIPTION LEGEND EXISTING NEW SAS — STS — SAAANITARRY STORM SEWER — SAS — — STS — WATER MAIN —W— SANITARY MANHOLE ELEVATIONS STORM EVATIONS STRUCTURE L PROPERTY LINE & R.O.W. y )" SURFACE DRAINAGE 7-72 0 LIGHT STANDARD • 0 STREET LIGHT 672.75 SPOT ELEVATION 67 --_- CONTOUR -G -G- GAS MAIN - G— G - �O MANHOLE V) ■ SAGE HILL professional SEPVICES SEA - EAST ANDOVER (MW ADD) 574 INDUSTRY DRIVE TUKWILA, WA 98188 CAMP+ ASSOCIATES 19401 40TH AVE W., SUITE 304 LYNNWOOD, WA 98036 CELL: (425) 280-8651 FAX: (425) 252-2860 W W W.CAMPASSOC.COM PROJECT MANAGER. EJC PREPARED BY. 410 APPROVED BY. EJC 10-29-14 ISSUED FOR FINAL PERMIT 10-28-14 ISSUED FOR PRELIM PERMIT REGISTERED ARCHI ECT TATE OF ASHINGTCN O CATCH BASIN • a FIRE HYDRANT • EASEMENT LINE - - FENCE - - UE/UT- - BURIED UTILITY LINE --UE/UT-- pJ UTILITY POLE >• -OE/OT- OVERHEAD UTILITY LINE -OE/OT- (11-) NORTH 50 100 150 BUILDING SCALE. 1' - 50'-0' (22x34), 1' - 100'-0' (11x17) LEGEND 111/79/J014 SH OVERALL SITE PLAN SHEET NUMBER A-1 PROJECT NUMBER 20141001203 EXISTING 3' 0" ACCESS GATE OUTLINE OF EXISTING PLATFORM WITH ANTENNAS ABOVE EXISTING 70'-0" HIGH MONOPOLE 22'_3.• EXISTING VERIZON WIRELESS ICE BRIDGE EXISTING HVAC UNITS, TYP. 1 ENLARGED SITE PLAN EXISTING CHAINLINK FENCE, TYP. EXISTING ROOF ACCESS LADDER EXISTING WALL MOUNTED EXHAUST EXISTING BUILDING 0 4 NORTH 8 12 MW ANTENNA / COAX SCHEDULE PATH ANTENNA QUANTITY C/L HEIGHT ANTENNA, TIP HEIGHT MW IAMETER TILT AZIMUTH MODEL COAX ROYAL HILL 1 NEW 66'-0" 67'-6" 1.76' 74.31' SP3-5.2 (1) RUN OF LDF4.5-50 GENERAL NOTES 1. VERIFY EACH COAXIAL CABLE LENGTH, DIAMETER, ROUTING, AND ALL MOUNTING APPURTENANCES WITH OWNER PRIOR TO ORDER. 2. THE MAXIMUM COAXIAL CABLE LENGTH HAS BEEN ESTIMATED WITH CORRESPONDING CABLE DIAMETER ON THE TABLE ABOVE. THIS CABLE LENGTH IS APPROXIMATE AND IS TO BE USED FOR CONSTRUCTION. ACTUAL ANTENNA CABLE LENGTHS MAY VARY FROM ESTIMATED MAXIMUM LENGTH AND MUST BE VERIFIED. 3. TAG ALL MAIN CABLES AT TWO (2) LOCATIONS: A - AT ANTENNAS B - INSIDE EQUIPMENT SHELTER / CABINET NEAR THE WAVEGUIDE ENTRY PORT. 4. EACH COAX SHALL BE SUPPORTED WITH COLUMN GRIP (CHINESE FINGER GRIP) HUNG FROM A J -HOOK AT TOP OF TOWER. 5. EACH COAX SHALL BE GROUNDED AT (3) THREE LOCATIONS; ANTENNA PLATFORM, TOWER BASE AND BUILDING ENTRY PORT SCALE. 3/8' - T-0' (22x34), 3/16' - 1'-0' (11x17) 2 ANTENNA/COAX SCHEDULE NOT TO SCALE 3 (E) VZW ANTENNA, TYP. \SfCTO if) 70 6-) (E) VZW ANTENNA, TYP. EXISTING ANTENNA PLAN (E) VZW ANNTENNA, TYP. (E) 70'-0" MONOPOLE (E) ANTENNA MOUNTING PLATFORM NORTH (E) VZW ANTENNA, TYP. (N) VZW MICROWAVE ANTENNA DISH 5 MOUNTED TO (E) -2 FRAME 157443) > ' `%4)SO ROY (SfCTO if) 706\ (E) VZW ANTENNA, TYP. SCALE. 3/8' - 1-0' (22x34), 3/16' - 1-0' (11x17) 4 NEW ANTENNA PLAN (E) VZW ANNTENNA, TYP. (0) 70'-0" MONOPOLE' (E) ANTENNA MOUNTING PLATFORM NORTH SCALE. 3/8' • 1-0' (22x34), 3/16' • 1-0' (11x17) NEW STANDARD ANTENNA MOUNTING PIPE ANTENNA MOUNTING FRAME NOTE: CONTRACTOR TO INSTALL HORIZONTAL SUPPORT AS REQUIRED. UNIVERSAL PIPE TO PIPE MICROWAVE ANTENNA PIPE MOUNT, SITE PRO PART #UPCx OR APPROVED EQUAL MICROWAVE ANTENNA MOUNTING ASSEMBLY PROVIDED BY MANUFACTURER MICROWAVE ANTENNA SEE PLAN FOR SIZE ANTENNA SIDE STRUT ATTACHED TO OUTER RING OF ANTENNA VALMONT MICROFLECT PART {/ B1061, ATTACH PER MICROWAVE MANUFACTURERS SPEC'S. PROVIDE 3 STRUTS PER ANTENNA (2 HORIZONTAL AXIS & 1 VERTICAL AXIS SUPPORT) L/C/ 9 5 ANTENNA MOUNTING DETAIL SCALE. 3/8' • 1'-0' (22x34), 3/16' - 1-0' (11x17) 772 5 SAGE HILL professional SErvICES SEA - EAST ANDOVER (MW ADD) 574 INDUSTRY DRIVE TUKWILA, WA 98188 0C CAMP+ ASSOCIATES 19401 40TH AVE W., SUITE 304 LYNNWOOD, WA 98036 CELL: (425) 280-8651 FAX: (425) 252-2860 W W W.CAMPASSOC.COM PROJECT MANAGER. EJC PREPARED BY. AIO APPROVED BY. EJC 10-29-14 155UED FOR FNAL FERMI"( 10-28-14 15511ED FOR PRELIM PERMIT REGISTERED ARCHI ECT UL TE OF ASHINGTO SHE 10/39/2014 ENLARGED SITE AND ANTENNA PLANS SHEET NUMBER A-2 PROJECT NUMBER 20141001203 EXISTING VERIZON WIRELESS ANTENNA, TYP. # C/L OF NEW V ON WIRELESS MW ANTENNA 66'-0" A.G.L. w NEW VERIZON WIRELESS MICROWAVE ANTENNA DISH EXISTING 70'-0" HIGH MONOPOLE EXISTING BUILDING EXISTING ROOF ACCESS LADDER / I rfl T/ OF EXISTING VERIZON WIRELESS ANTENNAS.. i�_ 76' NEW MW ANTENNA COAX TO FOLLOW EXISTING ROUTE T OF EXISTING MONOPOLE -- 70'-0" A.G.L. EXISTING VZW ICE BRIDGE EXISTING VZW CHAINLIK FENCE EXISTING HVAC EQUIPMENT 7 1 NEW NORTH ELEVATION SCALE. 1/8' - 1'-0• (22x34), 1/18• - 1'-0• (11x171 T/ OF EA.G.L.XISTING VERIZON WIRELESS ANTENNAS 76'-0" ±T/ 'OF -0" A.G.EXISTIL.NG MONOPOLE 70 EXISTING BUILDING EXISTING ROOF ACCESS LADDER EXISTING VZW ICE BRIDGE EXISTING HVAC EQUIPMENT GRADE 2 NEW EAST ELEVATION COAX ISA C,LL OF N W VZW MW_k ANTENNA 66'-0" A.G.L. Y NEW VERIZON WIRELESS MICROWAVE ANTENNA DISH ti4 -OoG9 15 7 NEW MW ANTENNA COAX TO FOLLOW EXISTING ROUTE 7 11 SAGE HILL protEsslonal services SEA - EAST ANDOVER (MW ADD) 574 INDUSTRY DRIVE TUKWILA, WA 98188 CAMP+ ASSOCIATES 19401 40TH AVE W, SUITE 304 LYNNWOOD, WA 98036 CELL: (425) 280-8651 FAX (425) 252-2860 W W W.CAMPASSOC.COM PROJECT MANAGER. EJC PREPARED BY. A10 APPROVED BY. EJC 10-29-14 ISSUED FOR FINAL PERMIT D FOR PRELIM PERMIT REGISTERED ARCHI ECT EXISTING VZW CHAINLIK FENCE 4 8 12 SCALE. 1/8' - 1'-0• (22x34), 1/18• - 1'-0• (11x17) ASHINGT 10/29/2014 ME ELEVATIONS SHEET NUMBER A-3 PROJECT NUMBER 20141001203 N 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. 2. ALL GROUNDING SHALL CONFORM TO THE CURRENT VERIZON WIRELESS STANDARDS. 3. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. 4, THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 5. PREFABRICATED SHELTER WILL BE PROVIDED WITH INTERNAL WIRING AND EQUIPMENT INSTALLED. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT REFER TO DRAWINGS PROVIDED BY SHELTER MANUFACTURER. 6. FOR INTERIOR EQUIPMENT LAYOUT AND LOCATION, SEE SHELTER MANUFACTURER'S DRAWINGS AND SPECIFICATION. IN CASE OF CONFLICT THE DRAWINGS GOVERN. 7. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). B. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING TWO (2) HIGH PRESS CRIMPS. 9. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. 10. ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT THEIR MATING SURFACES AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 11. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG TIN PLATED COPPER UNLESS OTHERWISE INDICATED. 12. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, 5/8"0 10-11. LONG. AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18" BELOW FINAL GRADE OR 6" BELOW FROST LINE FOR MAXIMUM DEPTH. 13. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. 1 GENERAL NOTES 14. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. 15. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE DR 6" MINIMUM BELOW THE FROST LINE. 16. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0" FROM EQUIPMENT CONCRETE PAD, SPREAD FOOTING, OR FENCE. 17. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED SPRAY. 18. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING 19. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURERS RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM) 20. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. 21. MINIMUM BENDING RADIUS FOR GROUNDING CONDUCTORS IS 8" WHEN BENDING IS NECESSARY. GROUND CONDUCTORS ARE TO BE AS STRAIGHT AS POSSIBLE. 22. NO SPLICES PERMITTED IN GROUND CONDUCTORS. 23. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S SPECIFIED VALUES. 24. GROUND BARS SHALL NOT BE FIELD MODIFIED. 25. ALL HORIZONTAL FENCE SECTIONS TO BE GROUNDED WITH 8" SINGLE BARREL GROUND STRAPS. 26. USE PANI SCHEME FOR LOADING ON MGB AS DISCUSSED IN NSTD 119, 33 & 36. JUMPER REQUIRED ONLY FOR 1-%"0 COAX OR FOR EASE OF CONNE CONNECTOR WEATHERPROOFING KIT (TYP.) REFER TO NOTE 2 FROM ANTENNA FRAME SUPPORT FROM ANTENNA MAST AIR TERMINALS (WHEN REQUIRED) RXO TO ANTENNAS TXO RX1 #6 AWG / J #2 AWG STRANDED, INSULATED COPPER CONDUCTOR. WEATHERPROOFING KIT (TYP.) STANDARD GROUND KIT (TYP.) REFER TO NOTE. ANTENNA CABLE IN CABLE TRAY TO EQUIPMENT LOCATION (TYP.) COLLECTION GROUND BAR MOUNTED NEAR/BELOW ANTENNA. REFER TO DETAIL 5, THIS SHT. #2 AWG STRANDED, INSULATED COPPER CONDUCTOR BONDED TO GROUND WIRE ALONG CABLE TRAY TO EXTERIOR GROUND BAR. ANTENNA CABLE WEATHERPROOFING KIT (SEE NOTE 3) CABLE GROUND KI 11' TO 14' #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) (SEE NOTE 1 & 2) CONNECTION OF COAX CABLE GROUND KIT TO ANTENNA CABLE 2 1/2"-- MAX. NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT WITH TWO -HOLE LUG. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. 2 COAXIAL CABLE GROUND WIRE TO GROUND BAR CONNECTION NOT TO SCALE 3 KEY NOTES. iO EXISTING ANTENNA MOUNTING FRAME, TYP. ONEW VERIZON WIRELESS ANTENNA, TYP. OEXISTING MASTER GROUND BAR AT BASE OF TOWER, NEAR EXIT PORT. 0 EXISTING MASTER GROUND BAR FINAL GROUND LEAD TO EXISTING TOWER GROUND RING OS ANTENNA GROUNDING, #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR TO COLLECTION GROUND BAR AT ANTENNA LEVEL OF TOWER, TYPICAL OCOLLECTION GROUND BAR FINAL GROUND LEAD, #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR TO MASTER GROUND BAR AT BASE OF TOWER, NEAR EXIT PORT ANTENNA GROUNDING PLAN STRANDED CU WIRE WITH GREEN, 600V, THHN/THWN INSULATION. SIZE AS SPECIFIED TWO -HOLE LUG, BOLTED TO GROUND BAR USING )"-16 x 1 )("STAINLESS STEEL HEX HEAD BOLTS AND HARDWARE. GROUND BAR ON WALL, FLOOR OR ON ANTENNA TOWCR 4 CAD WELD WITH #2 AWG SOLID TINNED BARE CU WIRE OR STRANDED CU WIRE WITH GREEN. 600V, THHN/THWN INSULATION TO ANTENNA STRUCTURE, BUILDING, RING GROUND OR MGB P oN oO OO O 000 O O O O > O >00 foo • GROUND BARS AT BOTTOM OF BUILDINGS, TOWERS OR MONOPOLES SHALL USE EXOTHERMIC CONNECTION. 0 O :�JJfA O J PANI SCHEME SPECIFICATIONS: PRODUCER (P) CONNECTS TO WIRELESS EQUIPMENT CABINETS, CABLE ENTRANCE GROUND BAR (CEGB), MAIN DISTRIBUTION FRAME GROUND BAR (MDFB), AND STANDBY ENGINE -GENERATOR SET FRAME AND OTHER NOISE PRODUCING EQUIPMENT ABSORBER (A) CONNECTS TO THE EARTH ELECTRODE SYSTEM INCLUDING CENTRAL OFFICE GROUND GRID, BUILDING STRUCTURAL GROUND, METALLIC WATER PIPE SYSTEM, ANTENNA SUPPORTING STRUCTURE GROUND SYSTEM, AND ELECTRICAL SERVICE ENTRANCE GROUND NON -ISOLATED (N) CONNECTS TO EQUIPMENT NOT IN AN ISOLATED GROUND ZONE (IGZ) SUCH AS CBN EQUIPMENT FRAME GROUNDS AND DC GROUND CONDUCTORS FOR DC POWER SYSTEMS THAT SERVE CBN OR BOTH CBN AND IBN EQUIPMENT ISOLATED (I) CONNECTS TO THE SINGLE POINT CONNECTION BAR (SPCB), FOR IBN EQUIPMENT GROUND BAR CONNECTION DETAIL AND NOTES SAGE HILL professional services SEA - EAST ANDOVER (MW ADD) 574 INDUSTRY DRIVE TUKWILA, WA 98188 OCAMP+ ASSOCIATES 19401 40TH AVE W., SUITE 304 LYNNWOOD, WA 98036 CELL: (425) 280-8651 FAX: (425) 252-2860 W W W.CAMPASSOC.COM PROJECT MANAGER. EJC PREPARED BY. 410 APPROVED BY. EJC NOT TO SCALE GENERAL NOTES. 1. ALL CADWELD CONNECTIONS ON GALVANIZED SURFACES SHALL BE CLEANED THOROUGHLY AND COVERED WITH TWO (2) COATS OF SHERWIN WILLIAMS GALVANITE PAINT B350W3 OR EQUAL. 2. ALL ELECTRICAL CADWELD AND MECHANICAL GROUND CONNECTIONS WILL HAVE NON -OXIDATION COMPOUND APPLIED TO CONNECTION. 3. ANY METAL OBJECTS WITHIN 6 FEET OF THE EXTERNAL GROUND RING SHALL BE GROUNDED. 4. ALL GROUNDING MATERIALS AND CADWELD MOLDS, SHOTS, ETC., SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR, UNLESS OTHERWISE NOTED. 5. THE ELECTRICAL CONTRACTOR SHALL FOLLOW GROUNDING SYSTEM INSTALLED AND TESTING PROCEDUR U4/wCO 9 SCALE. 1' - P-0' (22x34), 1/2' - 4-0' (11x17) #2 AWG STRANDED JUMPER W/ SHORT BAREL COMPESSION LUGS (T&B #54205 OR #5407), USE STAR WASHERS, LOCK WASHERS, AND SHEET METAL SCREWS TO SECURE TO EXTERNAL GROUND BAR BY CONTRACTOR. COAXIAL GROUND KITS W/ LONG BARREL COMPRESSION LUGS W/ TWO (2) 46"0 BOLTS AND LOCK WASHERS (TYP.) SUPPLY AND INSTALLED BY CONTRACTOR. 7/16" DIA. (TYP.) 10-29-14 ISSUED FOR FINAL PERMIT M. R11T REGISTERED ARCHI ECT 4" x 10" x )'4THK. COPPER GROUND BAR W/ 4" INSULATED STAND OFF. (HANGER #GBI-14410) SUPPLY AND INSTALL BY CONTRACTOR #2 AWG INSULATED STRANDED COPPER CONDUCTOR DOWNLEAD TO MASTER GROUND BAR OR OTHER FINAL GROUNDING POINT 5 COLLECTION GROUND BAR NOT TO SCALE ASHING 10/29/2019 ME GROUNDING PLAN AND DETAILS T SHEET NUMBER E-1 PROJECT NUMBER 20141001203 ON