Loading...
HomeMy WebLinkAboutOrd 1141 - Minimum Requirements for Fire Protection Systems in Buildings (Repealed by Ord 1528) CITY OF TUKWIL WASHINGTON ORDINANCE NO 1141 REPEALED BY 1528 AMENDED BY 1199 AN ORDINANCE ESTABLISHING MINIMUM REOUIREMENTS FOR FIRE PROTECTION SYSTEMS IN BUILDINGS WITHIN THE CITY OF TUKWILA USED FOR ASSEMBLY, EDUCATIONAL, INDUSTRIAL, INSTITUTIONAL, MERCANTILE, STORAGE, OFFICE AND MULTI- FAMILY DWELLING PURPOSES; AND REPEALING ORDINANCE #730 IN ITS ENTIRETY. NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, DO ORDAIN AS FOLLOWS: MEETING I DATE TY G /iu I /,y 8 1 9 11/4/ Buildings within the City of Tukwila used for assembly, educational, industrial, institutional, mercantile, storage, office and multi family dwelling purposes shall be equipped with fire protection systems which meet the following minimum requirements. A. Sprinkler Systems Required: A fully automatic sprinkler system designed, installed and tested per NFPA #13 (Current Edition) shall be installed in all new buildings in excess of 10,000 square feet total floor area. B. A fully automatic sprinkler system per (A) above may be required by the Chief of the Fire Department and the Officer in charge of the Fire Prevention Bureau for new buildings under 10,000 square feet total floor area when, in their judgement, any of the following conditions exist: Hazardous operations, hazardous contents, critical exposure problems, limited accessibility to the building, or other items which may contribute to definite fire hazards. C. Hose Stations Required: Hose stations (standpipes) shall be required in all new buildings. F. Existing Buildings: 1. Existing fully sprinklered buildings when remodeled or added on to shall retain the feature of being sprinklered in the remodeled or added on portion. COUNCIL ACTION 1. Hose shall be U.L. approved 1 1 /2" diameter lined fire hose, 75 feet in length with an adjustable (fog -type) plastic shut off type nozzle. 2. Design, installation and testing of hose stations shall comply with NFPA #14 (Current Edition) with any exceptions stated herein. 3. Hose stations shall be "wet." That is, water pressure shall be present at the individual station valves at all times. 4. All hose fittings shall be National Standard Thread, Higbee -Cut. D. Where this Ordinance conflicts with the Uniform Building Code requirements, the more stringent (greatest protection) shall apply E. Any exceptions to items covered by this Ordinance shall be made by the Chief of the Fire Department and the Officer in charge of the Fire Prevention Bureau. Such exceptions must be in writing. AGENDA I ACTION ITEM 2. If by adding on to an existing building, the resulting total structure falls within the coverage of (A) or (B) of this Ordinance, the entire structure shall be fully sprinklered. PASSED BY THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, at a regular meeting thereof thi s STday of Q 1980. U Approved as to Form: !L City Attorney G. Repealer: 1. Ordinance #730 is hereby repealed in its entirety. ATTEST: Mayor Deputy Clerk, Norma Booker Published Record Chronicle January 25, 1980